Loading...
occupant load (2).pdf0 FLOOR PLAN SCALE: 1/4" = 1'-0" GENERAL NOTES 1. ALL DIMENSIONS ARE TO FACE OF WALL, FACE OF EXISTING CONSTRUCTION U.N.O. 2. REFER TO SHEET A4.0 FOR ALL WALL & FLOOR FINISHES 3. REFER TO MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION 4, REFER TO THE LATEST ANYTIME FITNESS DESIGN MANUAL FOR ALL REQ'D. FURNITURE AND ACCESSORIES - GENERAL CONTRACTOR TO ASSEMBLE AND INSTALL OWNER SUPPLIED FURNITURE - VERIFY QUANTITIES W/ OWNER 5. ALL WALLS REPRESENTED IN PLANS AS FOLLOWS: EXISTING WALL CONST. TO REMAIN NEW METAL STUD WALL 6. WOOD STUDS MAY BE USED IN LIEU OF METAL STUDS AT THE DISCRETION OF THE GENERAL CONTRACTOR IF THE CONSTRUCTION TYPE ALLOWS FOR IT - VERIFY WITH ARCHITECT PRIOR TO CONSTRUCTION FLOOR PLAN LEGEND 1 EXIST STRUCTURAL STEEL COLUMN TO REMAIN 1t PROVIDE MIRRORS ALONG FACE OF WALL AS - PROTECT - PAINT INDICATED - FROM 2'-0" A.F.F. TO 8'-0" A.F.F. NERVE' CENTER LOCATION - REFER TO 2 ELECTRICAL SHEETS 12 WASHER & DRYER PROVIDED BY OWNER - OVERIFY THRESHOLD - 112" MAX. RISE WITH INSTALLED BY G.C. BEVELED SIDES THAT SLOPE 1:2 MAXIMUM - LOCATION OF T.V. - CONTRACTOR TO PROVIDE & PROVIDE 1/2" SADDLE AT ALL THRESHOLDS 13 O INSTALL POWER &DATA, REFER TO ELECTRICAL THAT ABUT TILE DRAWINGS. OWNER TO PROVIDE & INSTALL TVs WALL ASSEMBLY TO EXTEND TO AND MOUNTS - REFER TO 7/A7.2 FOR BLOCKING ORETAIL/LOGO a UNDERSIDE OF EXISTING ROOF ASSEMBLY DETAIL TYPICAL OWALL MOUNTED FIRE EXTINGUISHER - VERIFY 14 PROVIDE POSITIVE SLOPE TO SHOWER FLOOR FINAL LOCATION WITH LOCAL FIRE MARSHALL DRAINS - IF SLAB IS EXISTING, REMOVE PORTION OF SLAB AS NEEDED AND REPOUR TO LINE INDICATES CEILING TRANSITION REQUIRED SPECIFICATIONS - COORDINATE ODASHED s ABOVE SLOPES WITH FLOORING CONTRACTOR TO ACHIEVE CLEAN, SMOOTH TRANSITION O EXISTING ELECTRICAL PANEL, VERIFY IN FIELD 15 RESTROOM FLOOR DRAIN - REFER TO 91A7.2 OSERVICE SINK WITH MIXING VALVE- REFER TO PLUMBING DRAWINGS FOR ADDITIONAL 16 WRAP EXISTING COLUMN WITH GWB INFORMATION OPROVIDE 8'4' HIGH F.R.P. WAINSCOT 4'-0" 17 EXISTING 2 HOUR WALL TO BE MAINTAINED BEYOND LIMIT OF SERVICE SINK AT WALLS SURROUNDING SERVICE SINK 18 PROVIDE SPACER/COVER AT THIS SIDE OF WATER HEATER - REFER TO PLUMBING DOOR TO MATCH EXISTING COLUMN COVER AT O10 DRAWINGS STOREFRONT 19 EXISTING COLUMN WRAP TO REMAIN, PROTECT 3 DURING CONSTRUCTION. PATCH AND REPAIR AS NEEDED FOR NEW FINISH WALL TYPES o WALL TYPE #1 5/8" GYP. BD. 3-5/8" MTL. STUDS @ 16" O.C. 5/8" GYP. BD. - PROVIDE SOUND BATT INSUL. W/IN WALL ASSEMBLY - SEE FLOOR PLAN FOR LOCATIONS -WALL TO EXTEND TO BOTTOM OF STRUCTURE, U.N.O. WALL TYPE #4 ANYTIME FITNESS BRANDED WALL ASSEMBLIES - REFER TO DETAILS FOR CONSTRUCTION METHOD ON SHEET A7.0 VARIES WALL TYPE #5 5/8" GYP. BD. (PAINT) STUDS8" METAL O.C. J x 5/8/ MOISTURE RESISTANT GYP. BD. (RESTROOM SIDE) (PAINT) - AT ALL SHOWERS REPLACE MOISTURE RESISTANT GYP. BD. W/ CEMENTITIOUS SHEATHING - PROVIDE BLOCKING/BACKING AS REQ'D. - REFER TO GENERAL NOTE #16 ON SHEET A5.0 - PROVIDE SOUND BATT INSUL. W/IN WALL ASSEMBLY - SEE FLOOR PLAN FOR LOCATIONS WALL TO EXTEND TO BOTTOM OF STRUCTURE, U.N.O. WALL TYPE #6 5/8" GYP. BD. (PAINT) 6" METAL STUDS @ 16" O.C. / A A A A A A/ 5/8" MOISTURE RESISTANT GYP. BD. A n i/ A n J\ A (RESTROOM SIDE) (PAINT) AT ALL SHOWERS REPLACE MOISTURE RESISTANT GYP. BD. W/ CEMENTITIOUS SHEATHING - PROVIDE BLOCKING/BACKING AS REQ'D. - REFER TO GENERAL NOTE #16 ON SHEET A5.0 - PROVIDE SOUND BATT INSUL. W/IN WALL ASSEMBLY - SEE FLOOR PLAN FOR LOCATIONS -WALL TO EXTEND TO BOTTOM OF STRUCTURE, U.N.O. NJ I LTA JACKSON I MAIN ARCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM W Z o Lli N W Lo W UW ' W ?Wo Z 00 0�� LLWW�� W C) � � to �ZQoo f- 0 (D Z >—�c/)N2i zoW0o Q W N W z 0 a a w m o � H w a- d z co T N Q (D cc 5JROBERT STERED HIT CT KROESE STATE OF WASHINGTON PROJECT NO.: 18091 PROJECT MGR.: GP DRAWN BY: TAB CHECKED BY: GP FLOOR PLAN JUN 22 2u DEVELOP?A'LNT SERVIUtw r' 2111111 FED Df JACKSON I MAIN ARCHITECTURE P.S. © 2018