Loading...
10124 EDMONDS WAY_1012-Y F-J)MOA.)i)f (,J)'J/ From:SANDERSON FIRE PROTECTION To:4257710221 JUJANSUL]. McDonald's Restaurant: Nil � 'W( V� Store No. Licensee MCCopco Store Manager t/ Address _ _ Z012 / Z4ma*1 s City, State lip Code 9%02-0 Phone 11/16/2017 12:02 #357 P.001/001 FIRE SUPPRESSION SYSTEM ECKLIST Date / �� Authorized ANSUL Distributoo : Company SavtGt Cr50✓/i- I�D�`�C7i(/!� Address City, State 7Z eC,,- T G✓d� Zip Code 9Y7A Phone$06) Inspected By COOKING STATION/FIRE SYSTEM INFORMATION HOOD 1 4 Cooking Equipment Identification (e.g. 1G, 2G, 2V, 3V, 4V, Combo, Other) R-102 System Size (e.g. 3 gal., 6 gal., Other) "2HOOC�4HOOD Last R-102 Tank(s) Hydro Date(s)System is UL 300 Compliant (Yes/No) Note: Only genuine ANSUL components that are evaluated and included in the R-102 UL 300 systems listin� and installed in accordance with the R-102 System Design, Installation, Recharge, and Maintenance Manual (Part No. 418087) are allowed. "UL Classified" or generic components may not be substituted. The only exception Is for pipe, conduit, related fittings, and chrome sleeving (when required). Date of Tanks: Mild Steel (Cty) Date(s) Stainless Steel(Oty) _ Date(s) Z CHECK TYPE OF SERVICE PERFORMED: ❑ New Installation/Rebuild ❑ Seml-Annual Maintenance al Maintenance ❑ 12-Year Maintenance ❑ Recharge �e AAISUL R-102 Fire Suppression System(s) is installed, serviced, and/or recharged in accordance with the current R-102 System Design, Installation, Recharge, and Maintenance Manual (Part No. 418087), NFPA 17A, NFPA 96, and all applicable local.codes. ❑ Service Refused (by store Owner/Operator). Current Service Provider SERVICE PARTS No. of Nozzle Caps Replaced: Fusible Links Replaced (Oty): 165° 212' Verify genuine ANSUL cartridge seal is present:s Verify proper portable extinguishers are present: Dry Chemical Units: Model # f:92!fj� Last Hydro Date Model # ��� Last Hydro Date K-Class Units/F-Class its (where applicable): Model # lC Last Hydro Date Model # 24SS Last Hydro Date 280` 360° 3 450° 500° — ❑ No - if no, replace with new cartridge. Model if 15WC Last Hydro Date Modelif Last Hydro Date Model # Last Hydro Date Model # Last Hydro Date Note: Based on local code requirements, other tests or services may need to be performed. I certify that the restaurant fire suppression system(s) is installed in accordance with the R-102 System Design, �es ❑ Yes/exception ❑ No Installation, Recharge, and Maintenance Manual (Part No. 418087). 1 Certify that only genuine ANSUL components are present and that "UL Classified" or generic parts have not been substitutedO�Yes ❑ Yes/exception ❑ No It any part of the system service could not be performed, or "Yes/exception" was indicated above, explain: . SERVISIE TdCHNICIAN NAME (PRINT) G STOR MANAGER NAME (PRINT) SERVICE TECHNICIAN SIGNATURE STORE MANAGER SIGNATURE ORIGINAL — TYCO FIRE PROTECTION PRODUCTS CANARY — McDONALD'S MANAGER . ' PINK - DISTRIBUTOR 't'yCq One Stanton Street / Marinette, WI 54143-2542, USA / +1-715-735-7411 / www.ansul.com Fire Protection Products Copyright 0 2015 Tyco Fire Products LP. / All rights reserved. / Form No. F-2011200-03