1130 5TH AVE SsNoHdMiMZb. FIRE PREVENTION ON 1=and 12.425 Meridian Ave S INPPECTIEDMONDS REPORT Everett, WA 98208 BRIER Phone (425) 551-1200 0 MOUNTLAKE TERRACE [I UNINCORPORATED "JU-3 JL JL7&JL%j JL www.FireDistrict]-org Fax (425) 551-1272- LOCATION: 11305th Avenue 98020 BUSINESS NAME: Seavue Condos MAILING ADDRESS: 1130 5th Avenue S, Edmonds, WA 98020 BUSINESS OWNER: Leblon, Jean EMERGENCY-1: Grant, Jay KEY ACCESS-2: EMAIL: PERSON CONTACTED: NAME OF INSPECTOR: Serving Brier, Eam Mountlake Terrace PHONE: HOME PHONE: HOME PHONE: 2023519399 HOME PHONE: FREQUENCY I STATION 11 SHIFT Annual 17-D SCHEDULED Nov 2016 DATE DUE ► UFIR ► 427 152 CURRENT (4 kS i CITY NO BUSINESS��� LICENS INITIAL INSPECTION DATE SYSTEM DEVICES MODEL # TOTAL TESTED SATISFACTORY? Yes No NIA Horn/Strobes Mirtonc 12 Strobe Only 1 1 1 Horn Only 17 5peakerlStrobes Speaker Only Sounder Base RAID Manual Pulls Fri 9 Photo Smoke Detectors FCl 27 Ion Smoke Detectors Combination Smoke/Heat 1350 Rate of Rise Heat FC-1 13 200' Rate of Rise Heat 1350 Fixed Temp Heat 200" Fixed Temp Heat Duct Smoke Detectors Detector Remote Indicators Remote Annunciators 1 Elevator Recall Output Fan Pressurization Door Holders 7 Door Unlock Curtains/Roll-down Doors Fire Fighter Phones Main FACP Trouble with AG off? 64No Battery backup operational? jallo Battery voltage (no load)ofts Battery voltage (full load) •4 volts Charge circuit voltage voks Battery Size 1Av ".2(' .244 Panel T pe: Trouble with AG off? Y No Battery backup operational? No Battery voltage (no load) ► volts Battery voltage (full load) V-4 volts Charge circuit voltage Z-)volts Battery Size "J"-2oj Panel Type: Trouble with AG off? Yes No Battery backup operational? Yes No Battery voltage (no load) volts Battery voltage (full load) volts Charge circuit voltage volts Battery Size Panel T pe: Trouble with AC on Yes No Battery backup operational? Yes No Battery voltage (no load) volts Battery voltage (full load) volts Charge circuit voltage volts Battery Size Certification Given RED YELLOW WHITE :i{:: '::. {: .:i ...,t. .i:•n� .... .: ifs ... ..::{{� CONFIDENCE TEST ...... `h, \'hCSCCCyii'f 6,C,,, �\ ,'ti}ti}'LiC{ySt}'i�tiYiti'A\i 0.'h){f' 1w►za:366Ave W,Ruiu r•.,t.ynn%wxxi wAUM16IL.9.A. REPAIRS (425) 771-1166 FnM (425) 771-422 ; ; ; ::.;:::,::: •••:•,: FIRE ALARM SYSTEMS (One System per Report) occupancy Name: Stavin Condo Building Owner: Owner Agent: Occupancy Address: 1130 Sih Ave S, Edmonds Seavue Amncialian of Atrartment Ov Phone Number: 425-697-7226 Natfian Antes Date of Inspection: 02103n016 Testers Name: Ken Day Phone Number: 425-697-7226 Inspection Type: ✓ Annual Quarterly SFD Certification Number: scp-boG NIA Phone #: NSA Account #: NIA FACP Manufacturer. Fri Model #: 7100 Location: Basement electrical # of Initiating Circuits: 4 # of Signal Circuits: 2 Notes: ALARM SYSTEM FUNCTIONALITY Yes No NIA All notification circuits operational? All circuits checked for electrical supervision? All auxiliary equipment operates (elevators, fans, dampers) Key to panel available? Operating instructions at panel? Trouble Indicators function property's Test record posted at panel? Signals received at central station? Operator # •} PP Problems Found: AAW 2 Corrected By: Corrections Made: Date Corrected: SFD Certification #: Gym-e.:J'e) ��a� e. � 'T..Zc $ This certifies that this fire and life safety system has been properly inspected for reliability to cover the Items listed In this report and is consistent with Seattle Fire Department Fire Code standards, and th discrepanciesare noted and have been reported to the building Owner/Manager for correbtive acts >t.. Signature of Tester: hone #: Signature of Owner- 04 Serving Brier, Edmonds, and 12425 Meridian Ave S Mountlake Terrace Everett, WA 98208 Phone (425) 551-1200 www.FireDistr`ict1.or9: Fax (425) 551-1272 I LOCATION: 1130 r, fk Avu"Uu c 09020 BUSINESS NAME: Seavue Con Oos PHONE MAILING ADDRESS: 1130 th'Avenud­.'S"-.iEdMonds, WA 98020- BUSINESS OWNER: HOME PHONE: o1r.iL zo( ':" S EMERGENCY -I, -HOME PHONE: ' ji't,�'!H(JIVIE-PHONE: KEY ACCESS-2.. , EMAIL PERSON CONTACTED: NAME OF INSPECTOR: t4 FIRE SYSTEMS: FA 0/1 tE 6/1 3 1 FID LkiBox Date Last Serviced: I- IL 411-<-1 -0�— / 7:1) 1. 1 yh L.- -FIRE PREVENTION INSPECTION REPORT 0 EDMONDS 0 BRIER 0 MOUNTLAKE TERRACE [I UNINCORPORATED FREQUENCY STATION.& SHIFT Annual 17-C SCHEDULED DATE DUE o Nov 2015 LIFIR o 427 152 CURRENT CITY YES NO BUSINESS LICENSE E] El INITIAL INSPECTION DATE HAZARDS FOUND AND LOCATIONS COMMUNICATIONS _J - - _- ----- XAA rR .. ....... . . 2 .. .. . ..... ...... ....... .. . 3 3 4 4 6 6 7 Kk 7 I AGREE TO-CORRE THE ABOVE VIOLATION(S) IN THE NEXT 0 DAYS X 1st RE -INSPECTION grid RE -INSPECTION EXTENSION FINAL RE -INSPECTION VIOLATIONS _RATE DUE: EATEOLIE. GR4NTEDTO.�:.' DATE DUE:::,, CITED. PERSON 04AIC PERSON.CONTACTED: c CONTACTED CONTACTED: INSPECTOR:2 INSPECTOR: -,7 �T INSPECTOR: 77' DATE: DATE DAiE; 3 VIOLATIONS 1 f /�a 15 VIOLATIONS'- 5 PRE -CITATION LETTER SENT CITATION ISSUED NUMBER: 4 F1,011D CODE 5 2 6 DATE: RETURN RECEIPT SECTION: 6 3 7 3 7 RECEIVED DISPOSITION: 4 8 4 8 ' DATE:---.... LETTER NEEDED [] YES ❑ NO LETTER NEEDED C] YES ❑ NO OF ED41 °�N CITY OF EDMONDS 121 5TH AVENUE NORTH - EDMONDS, WA 98020 o PHONE: (425) 771-0220 - FAX: (425) 771-0221 STATUS: ISSUED 10/24/2013 „Permit # BLD2013; Expiration Date: 04/24/2014 ..`Prolect''Address 11" 0 5TH AVE S,`IEDMUNDS Parcel No: 00691200110000 P&*PEAT1'OVV11ER APPLICANT CONTRACTOR SEAVUE ASSOCIATION ABSCO ALARMS INC ABSCO ALARMS INC 1130 5TH AVE S UNIT B 1 NORTON, DANIEL J NORTON, DANIEL J EDMONDS, WA 98020-4666 19023 36Th Ave W #E 19023 36Th Ave W #E Lynnwood, WA 98036 Lynnwood, WA 98036 (425)412-7030 (425)771-1166 (425)771-1166 LICENSE #:ABSCOAI221BJ EXP:12/31/2013 1 : 1 t 1 NEW FIRE ALARM SYSTEM VALUATION: $0.00 PERMIT TYPE: Commercial PERMIT GROUP: 79 - Fire Alarm GRADING: N CYDS: 0 TYPE OF CONSTRUCTION: RETAINING WALL ROCKERY: N OCCUPANT GROUP: OCCUPANT LOAD: FENCE: N 0 X 0 'FT.) CODE: 12 OTHER: N ------ OTHER DESC: ZONE: NUMBER OF STORIES: 0 VESTED DATE: NUMBER OF DWELLING UNITS: 0 LOT #: BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 1 BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 13RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 FRONTSETBACK SIDESETBACK REQUIRED: PROPOSED: RE UIRED: PROPOSED: RE UIRED:, PROPOSED: HEIGHT ALLOWED:O PROPOSED:O RE UIRED: PROPOSED: SETBACK NOTES: I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. HIS APP N IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER D UTY 4ND ALL FEES ARE PAID. IT IS UNLAWFUL Name Date Date ATTENTION OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBC109/ IBC110/ IRCI 10, ONLINE APPLICANT ASSESSOR �4 0 THER �' L STATUS: ISSUED BLD20131086 CONDITIONS • Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check the job card for all required City inspections including final`project approval and final occupancy inspections. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paidupon submittal and are non-refundable. • Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. • Sound/Noise originating from temporary construction sites as a result of construction activity ate exempt from the.noise limits of ECC Chapter 5.30. only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating -from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5:30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to, indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from -any and all claims for damages of whatever nature, arising directly or indirectly from the issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. INSPECTIONS THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6) BUILDING (425) 771-0220 EXT. 1333 1 ENGINEERING (425) 771-0220 EXT. 1326 1 FIRE (425) 775-7720 PUBLIC WORKS (425) 771-0235 PRE-TREATMENT 425) 672-5755 RECYCLING (425) 275-4801 When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection beine requested, Contact Name and Phone Number, Date Prefereed, and whether you prefer mornine or afternoon. :e • F-Fire Alarm System Acceptance Absco Solutions INTEORATION THAT EMPOWERS AND PROTECTS BATTERY STANDBY REQUIREMENTS JOB NAME: Seavue Condominiums 19023 36th Avenue W, Suite E, Lynnwood, WA 98036 Phone: (425) 771 - 1166 Fax: (425) 771 - 4422 B.C. Code Description Standby Current amps Alarm Current amps Each Total Each Total 11 PC2W Horn/Strobe, 2/24 Volt, White, Multi- SIG 0.218 2.398 18 HW Horn Only, 12 or 24 volt, White, Wall SIG 0 0 0.069 1.242 1 P2RK Horn/Strobe, 12/24 Volt, Red, Multi- SIG 0 0 0.176 0.176 1 HPFF8 NAC Expander / Power supply PAN 0.05 0.05 0.1 0.1 2 SCW Strobe, 2/24 Volt, White, Multi- SIG 0.218 0.436 RO F RE E Totals: 0.05 4.352 NOTES: NAC BATTERY CALCULATIONS 24V 7AH BATTERY CAPACITY Total Standby Current: 0.05 X standby hours needed: 24.0 Total: 1.2 Total Alarm Current: 4.352 X fraction of hours needed: 0.083 Total: 0.3612 Total Standby: 1.2 + total alarm: 0.36120D Total: 1.5612 X d-factor: 1.2 OCT - 3 2013 Total Amp hour needed: 1.8735 . [Ni-� SEPi'v:CES CTR. FIRE COPYOF EDMONDS Absco Solutions INTEGRATION THAT EMPOWERS AND PROTECTS BATTERY STANDBY REQUIREMENTS JOB NAME: Seavue Condominiums 19023 36th Avenue W, Suite E, Lynnwood, WA 98036 Phone: (425) 771 - 1166 Fax: (425) 771 - 4422 B.C. Code Description Standby Current amps Alarm Current amps Each Total Each Total 1 7100-1 D-PLN 7100 FACP - Addressable PAN 0.085 0.085 0.105 0.105 1 LCD-7100 Remote series Annunciator for 7100 AUX 0.012 0.012 0.023 0.023 8 MS-7AF Addressable double action pull station INI 0.0003 0.0024 0.0006 0.0048 27 ASD-PL2F Analog photoelectric detector INI 0.0003 0.0081 0.0065 0.1755 17 ATD-RL2F Analog thermal sensor ROR & FT INI 0.0007 0.0119 0.015 0.255 3 AOM-2RF Addressable output relay control AUX 0.0003 0.0009 0.0003 0.0009 Totals: 0.1703 4.9162 NOTES: FACP BATTERY CALCULATIONS 24V 7AH BATTERY CAPACITY Total Standby Current: 0.1203 Total Alarm Current: 0.5642 X standby hours needed: 24.0 X fraction of hours needed: 0.083 Total: 2.8872 Total: 0.0468 Total Standby: 2.8872 + total alarm: 0.0468 Total: 2.934 X d-factor: 1.2 Total Amp hour needed: 3.5208 SYSTEM SENSOR Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlert' Advance selectable -output horns, strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. Features Electrically compatible with existing SpectrAlert products Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Plug-in design If T AIL i S y S The SpectrAlert Advance series of notification appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installation of individual devices, and 11 field -selectable candela settings for wall and ceiling strobes and horn/strobes. Field selectable candela settings on wall and ceiling units: 15,15/75, When installing Advance products, first attach a universal mounting 30, 75, 95, 1 10, 115, 135, 150, 177, 185 plate to a four -inch square, four -inch octagon or double -gang Same mounting plate for wall- and ceiling -mount units junction box. The two -wire mounting plate attaches to a single -gang junction box Shorting spring on mounting plate for continuity check before installation Tamper resistant construction Outdoor wall and ceiling products rated from —40°F to 151 °F Design allows minimal intrusion into the back box Horn rated at 88+ dbA at 16 volts Rotary switch for horn tone and three volume selections Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements Outdoor products NEMA 4X rated Compatible with MDL sync module Agency Listings &6NAUN0 U� C r(U� MA 7125-1653:186 (indoor strobes) 3CP1653187(outdoarstrobes) 7125-1653:188(hoMstrobes, ��.te UMD APPROVED approved chime/strbbe,) 713S-1653:189(hcrns,chimes) 54011 3023572 MEA4S2-OS-E 55512 53593 Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn/strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves.The device will rotate into position, locking the product's pins into the mounting plate's terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceding. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Advance Specifications General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 > 4 - 11/ -inch back box, 4-inch octagon back box or double -gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 1 1/8-inch back box A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field -selectable candela settings including 15,15/75, 30 75, 95,110, 115, 135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three -pattern and a non -temporal (continuous) pattern.These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non -coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three -fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 41 /,6 x 41 /16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) K Series Operating Temperature -40°F to 151 °F (-40oC to 66°C) Humidity Range 10 to 93% non -condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range' 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 68'diameter x 2 5'high (173 mm diameter x 64 mm high) Wall mount dimensions (including lens) 5 61 x 4 7 W x 2.5-D (142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61 x 4.7"W x 1.3"D (142 mm L x 119 mm W x 33 mm D) Wall -mount back box skirt dimensions (BBS-2, BBSW-2) 5 91 x 5 OWN . 2 2 D (151 mm L x 128 mm W - 56 mm D) Ceiling -mount back box skirt dimensions (BBSC-2, BBSCW-2) 7.1 "diameter x 2.25"high (180 mm diameter x 57 mm high) Wall -mount weatherproof back box dimensions (SA-WBB) 5 71, 5 1 -We 2.0-D (145 mm L x 130 mm W x 51 mm D) Ceiling -mount weatherproof back box dimensions (SA-WBBC) 7.1 "diameter / 2 0" high (180 mm diameter ,- 51 mm high) Wall -mount trim ring dimensions (TR-HS, TRW-HS) 5.7-L', 4.812NV x 0.35"D (146 mm L x 122 W mm , 9 D mm) Ceiling -mount trim ring dimensions (TRC-HS, TRCW-HS) 6.9-diameter x 0.35 high (176 mm diameter x 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12V nominal only for 15 and 15/75 cd. A05-0395-005 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB Standard 15* 123 128 66 71 Candela Range 15/75* 142 148 77 81 30* NA NA 94 96 75* NA NA 158 153 95* NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non -temporal High 57 56 69 75 Non -temporal Medium 42 50 60 69 Non -temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -temporal High 141 152 91 100 116 176 201 221 229 Non -temporal Medium 133 145 75 85 102 163 187 207 216 Non -temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -temporal High 142 161 103 112 126 181 203 221 229 Non -temporal Medium 134 155 85 95 110 166 189 208 216 Non -temporal Low 132 154 80 90 105 161 184 202 211 DC Input 16-33 Volts 135 Horn/Strobe, 150 High 177 Candela 185 Range (135-185 cd) FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -temporal High 255 270 303 309 Non -temporal High 233 248 275 281 Non -temporal Medium 242 259 293 299 Non temporal Medium 219 232 262 267 Non -temporal Low 238 254 291 295 Non -temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Horn Tones and Sound Output Data Horn and Horn/Strobe Output (dBA) 24 Volt Nominal Strobe Output (cd) Listed Candela Candela rating at -40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 Switch Position Sound Pattern dB 8-17.5 Volts DC FWR 16-33 Volts DC FWR Reverberant DC FWR Anechoic DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non -temporal High 82 82 88 88 93 92 100 100 5 Non -temporal Medium 78 78 85 85 90 90 98 98 6 Non -temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 +Settings 7, 8, and 9 are not available on 2-wire horn/strobe. A05-0395-005 SpectrAlert Advance Dimensions 2.5" I Ceiling -mount horn/strobes I rt •7.1" 2.25+1 0• Da 5.02.23+Dia. 00.°o c� 7 / 2.0" 0 o e 5.98' 6.2' 1 0 o G �Cj. � Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Model Description Model Description Horn/Strobes Ceiling Horn/Strobes (contd.) P2R*t 2-wire Horn/Strobe, Standard cd*, Red PC4W 4-wire Horn/Strobe, Standard cd, White P2RH* 2-wire Horn/Strobe, High cd, Red PC4WH 4-wire Horn/Strobe, High cd, White P2RK*° 2-wire Horn/Strobe, Standard cd, Red, Outdoor Ceiling Strobes P2RHK° 2-wire Horn/Strobe, High cd, Red, Outdoor SCR* Strobe, Standard cd, Red P2W* 2-wire Horn/Strobe, Standard cd, White SCRH* Strobe, High cd, Red P2WH* 2-wire Horn/Strobe, High cd, White SCRK° Strobe, Standard cd, Red, Outdoor P4R* 4-wire Horn/Strobe, Standard cd, Red SCRHK° Strobe, High cd, Red, Outdoor P4RH* 4-wire Horn/Strobe, High cd, Red SCW*t Strobe, Standard cd, White PORK' 4-wire Horn/Strobe, Standard cd, Red, Outdoor SCWH*t Strobe, High cd, White P4RHK° 4-wire Horn/Strobe, High cd, Red, Outdoor Horns P4W* 4-wire Horn/Strobe, Standard cd, White HR Horn, Red P4WH* 4-wire Horn/Strobe, High cd, White HRK° Horn, Red, Outdoor Wall Strobes HW Horn, White SR*t Strobe, Standard cd, Red Accessories SRH*t Strobe, High cd, Red BBS-2 Back Box Skirt, Wall, Red SRK° Strobe, Standard cd, Red, Outdoor BBSW-2 Back Box Skirt, Wall, White SRHK Strobe, High cd, Red, Outdoor BBSC-2 Back Box Skirt, Ceiling, Red SW* Strobe, Standard cd, White BBSCW-2 Back Box Skirt, Ceiling, White SWH* Strobe, High cd, White TR-HS Trim Ring, Wall, Red Ceiling Horn/Strobes TRW-HS Trim Ring, Wall White PC2R* 2-wire Horn/Strobe, Standard cd, Red TRC-HS Trim Ring, Ceiling, Red PC2RH* 2-wire Horn/Strobe, High cd, Red TRCW-HS Trim Ring, Ceiling, White PC2RK° 2-wire Horn/Strobe, Standard cd, Red, Outdoor Notes: PC2RHK° 2-wire Horn/Strobe, High cd, Red, Outdoor * Add"-P"to model number for plain housing (no"FIRE"marking on cover), e.g., PC2W*t 2-wire Horn/Strobe, Standard cd, White P213-P. PC2WH*t 2-wire Horn/Strobe, High cd, White t Add "-SP"to model number for"FUEGO"marking on cover, e g, P2R-SP # "Standard cd," refers to strobes that include 15,15/75, 30, 75, 95,110, and 115 PC4R 4-wire Horn/Strobe, Standard cd, Red candela settings."High cd," refers to strobes that include 135, 150, 177, and 185 PC4RH 4-wire Horn/Strobe, High cd, Red candela settings. PC4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor All outdoor units ending in "K" include a weatherproof back box. PC4RHK° 4-wire Horn/Strobe, High cd, Red, Outdoor a Add "-R"to model number for weatherproof replacement device (no back box �{ included). l ��\ 0200a System Sensor. `_ f �✓I J 3825 Ohio Avenue • St. Charles, IL 60174 Product speaficztions subjxtto diangewiNout notice.Nst[sys[emsensw.com for SENSOR Phone-SENSOR2•Fax A05-0395-0OS•8/OB•#2 630-377-6495 �rr�ntpoduainfomanoq,indudin.8/08.esionof[hisdatahee. a2018 �Gamew ell SpectrAlert® Advance ®I UMENrfS Selectable Output Notification Appliances by Honeywell &WWMo mU RX% General SpectrAlert Advance selectable -output horns, strobes and horn/strobes are rich with features guaranteed to cut installa- tion times and maximize profits. The SpectrAlert Advance series of notification appliances is designed to simplify your installations, with features such as: plug-in designs, instant feedback messages to ensure correct installation of individual devices, and eleven field -selectable candela settings for wall and ceiling strobes and horn/strobes. More specifically, when installing Advance products, first attach a universal mounting plate to a four -inch square, four - inch octagon, or double -gang junction box. The two -wire mounting plate attaches to a single -gang junction box. Then, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe, or horn/strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the prod- uct's pins into the mounting plate's terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. SpectrAlert Advance products allow you to choose: • 12 or 24 volts. • At 24 volts, 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, or 185 candela by way of rear -mounted slide switch and front viewing window. • Horn tones and volume by way of rotary switch. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two -wire and four -wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between —40°F and 151 °F (-40°C and 66°C) in wet or dry applications. Models available: • Indoor wall -mount: horn, strobe, 2-wire horn/strobe, 4-wire horn/strobe. • Indoor ceiling -mount: strobe, 2-wire horn/strobe, 4-wire horn/strobe. • Outdoor wall -mount: horn, strobe, 2-wire horn/strobe, 4- wire horn/strobe. • Outdoor ceiling -mount: strobe, 2-wire horn/strobe, 4-wire horn/strobe. Features • Plug-in design. • Same mounting plate for wall- and ceiling -mount units. • Shorting spring on mounting plate for continuity check before installation. • Captive mounting screw. • Tamper -resistance capability. • Field -selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. • Automatic selection of 12 or 24 volt operation at 15 and 15/ 75 candela. • Outdoor wall and ceiling products. • Outdoor products rated from —40°F and 151°F (-40•C and 66°C). 7087phol.jpg 7087pho2jpg Indoor Ceiling Horn/Strobe Outdoor Ceiling Strobe 7087pho3.jpg � ©il Indoor Wall Horn/Strobe 7087pho5.jpg Indoor Wall Horn 7087pho4,jpg Indoor Ceiling Strobe 7087pho6jpg )utdoor Wall Strobe • Minimal intrusion into the backbox. • Horn rated at 88+ dbA at 16 volts. • Rotary switch for tone selection. • Three horn volume settings. • Electrically compatible with existing SpectrAlert products. Engineering Specifications SpectrAlert Advance horns, strobes, and horn/strobes shall mount to a standard 4.0" x 4.0" x 1.5" (10.16 x 10.16 x 3.81 cm) backbox, 4.0" (10.16 cm) octagonal backbox, or a double - gang backbox. Two -wire products shall also mount to a single - gang 2.0" x 4.0" x 1.875" (5.08 x 10.16 x 4.763 cm) backbox. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•CircuitTm Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and 120°F (0•C and 49•C) from a CS-2539 • 09/01/06 — Page 1 of 4 regulated DC, or full -wave -rectified, unfiltered power supply. Strobes and horn/strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177. 185. STROBE The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appli- ances, flashing at 1 Hz over the strobe's entire operating volt- age range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. HORN/STROBE COMBINATION The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a Temporal 3 pattern and a Non - Temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn/ strobe models shall operate on a coded or non -coded power supply. OUTDOOR PRODUCTS SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between —40°F and 151°F (-40°C and 66°C). The products shall be listed for use with a System Sensor outdoor/weather- proof backbox with half -inch and three -fourths -inch conduit entries. SYNCHRONIZATION MODULE The module shall be a System Sensor Sync -Circuit listed to UL 464 and shall be approved for fire protective ser- vice. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at Temporal 3. Also, while operating the strobes, the Strobe Current Draw, UL Maximum (mA RMS) Candela 8-17.5V 16-33V DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15175 142 148 77 81 30 NA N/A 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Page 2 of 4 — CS-2539 • 09101106 module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 4.688" x 4.688" x 2.125" (11.906 x 11.906 x 5.398 cm) backbox. The module shall also control two Style Y (class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multi- ple zones. Daisy -chaining two or more synchronization mod- ules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Operating Specifications Standard operating temperature: 32°F to 120°F (0°C to WC). K Series operating temperature: —40oF and 15l °F (-40oC and 66°C). Humidity range: 10% to 93% non -condensing (indoor prod- ucts). Strobe flash rate: 1 flash per second. Nominal voltage: regulated 12 VDC/FWR or regulated 24 VDC/FWR. NOTE: Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. Operating voltage range: 8 V to 17.5 V (12 V nominal); or 16 V to 33 V (24 V nominal). NOTE: P, S, PC, and SC products will operate at 12 V nominal only for 15 cd and 15175 cd. Input terminal wire gauge: 12 to 18 AWG (3.31 to 0.821 mm'). Ceiling -mount dimensions (including lens): 6.8" diameter x 2.5" deep (17.3 cm diameter x 6.4 cm deep). Wall -mount dimensions (including lens): 5.6" H x 4.7" W x 2.5" D (14.2 cm H x 11.9 cm W x 6.4 cm D). Horn dimensions: 5.6" H x 4.7" W x 1.3" D (14.2 cm H x 11.9 cmWx3.3cmD). Agency Listings and Approvals The listings and approvals below apply to SpectrAlert Advance Selectable Output Notification Devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing sta- tus. • UL Listed: file Horn Current Draw, UL Maximum (mA RMS) Sound Pattern dB 8-17.5V 16-33V DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non -temporal High 57 56 69 75 Non -temporal Medium 42 50 60 69 Non -temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 Horn and Horn/Strobe Rotary Switch Setting) Horn and Horn/Strobe Output (dBA) Setting Repetition Rate dB Level 1 Temporal horn High 2 Temporal horn Medium 3 Temporal horn Low 4 Normal horn High 5 Normal horn Medium 6 Normal horn Low 7' Externally coded High 8' Externally coded Medium 9' Externally coded Low 'NOTE: Settings 7, 8, and 9 are not available on 2-wire horn/strobe. Switch Position Sound Pattern dB 8-17.5V 16-33V DC FWR DC FWR 1 Temporal High 78 78 84 84 2 Temporal Medium 74 74 80 80 3 Temporal Low 71 73 76 76 4 Non -temporal High 82 82 88 88 5 Non -temporal Medium 78 78 85 85 6 Non -temporal Low 75 75 81 81 7' Coded High 82 82 88 88 8' Coded Medium 78 78 85 85 9'j Coded Low 75 75 81 81 `NOTE: Settings 7, 8, and 9 are not available on 2-wire horn/strobe. Two -Wire Horn/Strobe, STANDARD Candela Range (15 — 115 cd), UL Maximum Current Draw (mA RMS) Input, Sound Pattern, dB Level 8-17.5V 16-33V 15 15/75 15 15/75 30 75 95 110 115 DC Input, Temporal, High 137 147 79 90 107 176 194 212 218 DC Input, Temporal, Medium 132 144 69 80 97 157 182 201 210 DC Input, Temporal, Low 132 143 66 77 93 154 179 198 207 DC Input, Non -temporal, High 141 152 91 100 116 176 201 221 229 DC Input, Non -temporal, Medium 133 145 75 85 102 163 187 207 216 DC Input, Non -temporal, Low 131 144 68 79 96 156 182 201 210 FWR Input, Temporal, High 136 155 88 97 112 168 190 210 218 FWR Input, Temporal, Medium 129 152 78 88 103 160 184 202 206 FWR Input, Temporal, Low 129 151 76 86 101 160 184 194 201 FWR Input, Non -temporal, High 142 161 103 112 126 181 203 221 229 FWR Input, Non -temporal, Medium 134 155 85 95 110 166 189 208 216 FWR Input, Non -temporal, Low 132 154 80 90 105 161 184 202 211 Two -Wire Horn/Strobe, HIGH Candela Range (135 — 185 cd), UL Maximum Current Draw (mA RMS) DC Input 16-33V FWR Input 16-33V 135 150 177 185 135 150 177 185 DC, Temporal, High 245 259 290 297 FWR, Temporal, High 215 231 258 265 DC, Temporal, Medium 235 253 288 297 FWR, Temporal, Medium 209 224 250 258 DC, Temporal, Low 232 251 282 292 FWR, Temporal, Low 207 221 248 256 DC, Non -temporal, High 255 270 303 309 FWR, Non -temporal, High 233 248 275 281 DC, Non -temporal, Medium 242 259 293 299 FWR, Non -temporal, Medium 1 219 232 262 267 DC, Non -temporal, Low 238 254 291 295 FWR, Non -temporal, Low 214 229 256 262 CS-2539 • 09/01/06 — Page 3 of 4 Ordering Information Model Description Model Description WALL HORN/STROBES CEILING HORN/STROBES P2R 2-wire horn/strobe, standard cd, red. PC2R 2-wire horn/strobe, standard cd, red. P2RH 2-wire horn/strobe, high cd, red. PC2RH 2-wire horn/strobe, high cd, red. P2RK 2-wire horn/strobe, standard cd, red, outdoor. PC2RK 2-wire horn/strobe, standard cd, red, outdoor. P2RHK 2-wire horn/strobe, high cd, red, outdoor. PC2RHK 2-wire horn/strobe, high cd, red, outdoor. P2W 2-wire horn/strobe, standard cd, white. PC21N 2-wire horn/strobe, standard cd, white. P2WH 2-wire horn/strobe, high cd, white. PC2WH 2-wire horn/strobe, high cd, white. P4R 4-wire horn/strobe, standard cd, red. PC4R 4-wire horn/strobe, standard cd, red. P4RH 4-wire horn/strobe, high cd, red. PC4RH 4-wire horn/strobe, high cd, red. P4RK 4-wire horn/strobe, standard cd, red, outdoor. PC4RK 4-wire horn/strobe, standard cd, red, outdoor. P4RHK 4-wire horn/strobe, high cd, red, outdoor. PC4RHK 4-wire horn/strobe, high cd, red, outdoor. P41N 4-wire horn/strobe, standard cd, white. PC4W 4-wire horn/strobe, standard cd, white. P4WH 4-wire hom/strobe, high cd, white. PC4WH 4-wire horn/strobe, high cd, white. WALL STROBES CEILING STROBES SR Strobe, standard cd, red. SCR, Strobe, standard cd, red. SRH Strobe, high cd, red. SCRH Strobe, high cd, red. SRK Strobe, standard cd, red, outdoor. SCRK Strobe, standard cd, red, outdoor. SRHK Strobe, high cd, red, outdoor. SCRHK ISCWH Strobe, high cd, red, outdoor. SW Strobe, standard cd, white. SCW Strobe, standard cd, white. SWH Strobe, high cd, white. Strobe, high cd, white. ACCESSORIES HORNS BBS-2 Backbox skirt, wall, red. HR Horn, red. BBSW-2 Backbox skirt, wall, white. HRK Horn, red, outdoor. BBSC-2 Backbox skirt, ceiling, red. HW Horn, white. BBSCW-2 Backbox skirt, ceiling, white. NOTE: "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. "Standard cd" refers to strobes that include 15, 15175, 30, 75, 95, 110, and 115 candela settings. 6.8" dia. 7087dni.tif Sync-CircuitTM" is a trademark, and Gamewell®, SpectrAlert®, and System Sensor® are registered trademarks of Honeywell International Inc. 02006 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472 - Phone: (203) 484-7161 - FAX: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. 02006 Gamewell-FCI. All rights reserved. www.gamewell-fci.com Page 4 of 4 — CS-2539 • 09/01/06 SYSTEM SENSOR' Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlert* Advance selectable -output horns, strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. The SpectrAlert Advance series of notification appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installation of individual devices, and 11 field -selectable candela settings for wall and ceiling strobes and horn/strobes. When installing Advance products, first attach a universal mounting plate to a four -inch square, four -inch octagon or double -gang junction box. The two -wire mounting plate attaches to a single -gang junction box. Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn/strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the product's pins into the mounting plate's terminals.The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Features • Electrically compatible with existing SpectrAlert products • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Plug-in design • Field selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95,110,115, 135,150, 177,185 • Same mounting plate for wall- and ceiling -mount units • Shorting spring on mounting plate for continuity check before installation -Tamper resistant construction • Outdoor wall and ceiling products rated from —40oF to 151°F • Design allows minimal intrusion into the back box • Horn rated at 88+ dbA at 16 volts • Rotary switch for horn tone and three volume selections • Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements Outdoor products rainproof per UL 50 (NEMA 3R) • Compatible with MDL sync module Agency Listings a�wnre UL M� e ■ � EA q ;� 7125-1653:186 (indoor strobes) 7300-1653:187 (outdoor strobes) 7125-1653:1 b8 LISTED APPROVED approved (hmNsnobess ) 7135-1653.189(hans, chimes) 54011 3023572 MEA452-05-E 55512 S3593 SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4 x 11k-inch back box, 4-inch octagon back box or double -gang back box.Two-wire products shall also mount to a single -gang 2 x 4 x 11/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync -Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 175 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field -selectable candela settings including 15,15/75, 30, 75, 95,110,115,135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobes entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three -pattern and a non -temporal (continuous) pattern.These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non -coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three -fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 41V1e x 41 /1e x 21/s-inch back box.The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120T (0°C to 49 Q K Series Operating Temperature -40°F to 151 T (-40°C to 66°Q Humidity Range 10 to 93% non -condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range' 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8" diameter x 25"high (173 mm diameter x 64 mm high) Wall mount dimensions (including lens) 5.61 x 4.7 W x 25-D (142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61 x 4.7 W x 1.3"D (142 mm L x 119 mm W x 33 mm D) Wall -mount back box skirt dimensions (BBS-2, BBSW-2) 5.91 x 5.0W x 2.2 D (151 mm L x 128 mm W x 56 mm D) Ceiling -mount back box skirt dimensions (BBSC-2, BBSCW-2) 7.1 "diameter x 2.25-high (180 mm diameter x 57 mm high) Wall -mount weatherproof back box dimensions (SA-WBB) 5.71 x 5.1 W x 2.0"D (145 mm L x 130 mm W x 51 mm D) Ceiling -mount weatherproof back box dimensions (SA-WBBC) 7.1 "diameter x 2.0" high (180 mm diameter x 51 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. n.7M -17511ai UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB 8-17.5 Volts 16-33 Volts DC FWR DC FWR Standard 15* 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75* 142 148 77 81 Temporal Medium 44 49 58 69 30* NA NA 94 96 Temporal Low 38 44 44 48 75* NA NA 158 153 Non -temporal High 57 56 69 75 95* NA NA 181 176 Non -temporal Medium 42 50 60 69 110 NA NA 202 195 Non -temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-wire Horn/Strobe, Standard Candela Range (115-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -temporal High 141 152 91 100 116 176 201 221 229 Non -temporal Medium 133 145 75 85 102 163 187 207 216 Non -temporal Low 131 144 68 79 % 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -temporal High 142 161 103 112 126 181 203 221 229 Non -temporal Medium 134 155 85 95 110 166 189 208 216 Non -temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-wire Horn/Strobe, High Candela Range (135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -temporal High 255 270 303 309 Non -temporal High 233 248 275 281 Non -temporal Medium 242 259 293 299 Non -temporal Medium 219 232 262 267 Non -temporal Low 238 254 291 295 Non -temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed candela I Horn and Horn/Strobe Output (dBA) ratings must be reduced in accordance with this table. 24 Volt Nominal Strobe Output (cd) 8-17.5 16-33 Listed Candela Candela rating at -40°F 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 % 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non -temporal High 82 82 88 88 93 92 100 100 5 Non -temporal Medium 78 78 85 85 90 90 98 98 6 Non -temporal Low 75 75 81 81 88 84 96 92 7r Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9' Coded Low 75 75 81 81 88 85 96 92 'Settings 7, 8, and 9 are not available on 2-wire horn/strobe. A0W395-003 SpectrAlert Advance Dimensions Wall -mount horn/strobes Ceiling -mount horn/strobes O O o & o � 0 7.1 ' 2.25" 2.0ia. 5.05' 2.23tj Dia. 1` D2n `y- .0 V O 5)8" 5.7" / O O O !:fj Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Model Description Model Description Horn/Strobes Ceiling Horn/Strobes (contd.) P2R"+ 2-wire Horn/Strobe, Standard cd*, Red PC2W"t 2-wire Horn/Strobe, Standard cd, White P2RH• 2-wire Horn/Strobe, High cd, Red PC2WH.t 2-wire Horn/Strobe, High cd, White P2RK" 2-wire Horn/Strobe, Standard cd, Red, Outdoor PC4R 4-wire Horn/Strobe, Standard cd, Red P2RHK' 2-wire Horn/Strobe, High cd, Red, Outdoor PC4RH 4-wire Horn/Strobe, High cd, Red P2W 2-wire Horn/Strobe, Standard cd, White PC4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor P2WH' 2-wire Horn/Strobe, High cd, White PC4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor P4R` 4-wire Horn/Strobe, Standard cd, Red PC4W 4-wire Horn/Strobe, Standard cd, White P4RH• 4-wire Horn/Strobe, High cd, Red PC4WH 4-wire Horn/Strobe, High cd, White P4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor Ceiling Strobes P4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor SCR' Strobe, Standard cd, Red P4W 4-wire Horn/Strobe, Standard cd, White SCRH• Strobe, High cd, Red P4WH* 4-wire Horn/Strobe, High cd, White SCRK Strobe, Standard cd, Red, Outdoor Wall Strobes SCRHK Strobe, High cd, Red, Outdoor SR't Strobe, Standard cd, Red SCWt Strobe, Standard cd, White SRH't Strobe, High cd, Red SCWH't Strobe, High cd, White SRK Strobe, Standard cd, Red, Outdoor Horns SRHK Strobe, High cd, Red, Outdoor HR Horn, Red SW' Strobe, Standard cd, White HRK Horn, Red, Outdoor SWH" Strobe, High cd, White HW Horn, White Ceiling Horn/Strobes Accessories PC2R' 2-wire Horn/Strobe, Standard cd, Red BBS-2 Back Box Skirt, Wall, Red PC2RH` 2-wire Horn/Strobe, High cd, Red BBSW-2 Back Box Skirt, Wall, White PC2RK 2-wire Horn/Strobe, Standard cd, Red, Outdoor BBSC-2 Back Box Skirt, Ceiling, Red PC2RHK 2-wire Horn/Strobe, High cd, Red, Outdoor BBSCW-2 Back Box Skirt, Ceiling, White Notes: " Add "-P"to model number for plain housing (no"FIRE" marking on cover), e.g., P2R-P t Add "-SP" to model number for"FUEGO" marking on cover, e.g., P2R-SP # "Standard cd"refers to strobes that include 15,15/75, 30, 75, 95,110, and 115 candela settings."High cd"refers to strobes that include 135, 150, 177, and 185 candela settings. All outdoor units ending in "K" include a weatherproof back box. "STEM 020065ystem Sensor. ��II �I 3825 Ohio Avenue • St. Charles, IL 60174 Nodutt speofi[aibns wgectto diange witlwutndke.Nsi[rys[crosensarwmfa SENSOR Phone: 800-SENSOR2•Fax: 630-377-6495 Nrrentpo0uttinfam05-03i5-003-g2/06-stversbndthisdatash[e. A05-0395-003. 1 L06 • Y1676 Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The Gamewell-FCI 7100 Series fire alarm control panel is a multi processor -based, analog addressable system. The control panel is a compact, yet expandable, platform. Intended for commercial, industrial and institutional instal- lations, the 7100 Series is ideal for life safety and property protection fire alarm applications. The basic 7100 Series control panel provides one (1) or two (2), analog addressable Signaling Line Circuits (SLCs). Each SLC supports up to ninety-eight (98) analog address- able sensors, as well as up to ninety-nine (99) addressable monitor modules and/or control points. With 197 addresses available on the 7100-1 and 394 addresses available on the 7100-2. The 7100 uses an advanced protocol that ensures an almost instant response to events while at the same time suppressing nuisance alarms. The system may be programmed with either the Windows® -based Field Configuration Program (FCP-7100) or configured through a comprehensive set of intuitive, secure password protected front -panel programming options. This important feature allows the system to quickly adapt to any future requirements due to changes in occu- pancies, building remodels, or other contingencies. The sophisticated circuitry and powerful analog software enables the 7100 Series fire alarm control panel to read the specific sensitivity level of each sensor and compensate for changes due to age, dust accumulation or other environ- mental factors. The 7100 incorporates the Gamewell-FCI Listed Integrated Sensitivity Testing (LIST) which meets NFPA 72 sensitivity testing and maintenance requirements. The LIST testing allows substantial savings in both mainte- nance and service while eliminating nuisance alarms. The Model 7100-1 D and 2D features an integral Digital Alarm Communicator Transmitter (DACT) with all popular transmission formats and a 16-digit telephone number field. It is 8-digit Carrier Information Code (CIC) compliant and also prevents "dialer -runaway" in the event of intermit- tent system faults. The 7100-1D and 2D are UL Listed for Microsoft® Word® is a registered trademark of Microsoft® Corporation. 7100 Series Compact Analog Addressable Fire Alarm Control Panel 7100 Series Features • Listed per ANSI/UL 864 9th Edition • 120 or 240 VAC (optional) input line voltage • Front panel programming with day/night sensitivity adjustments • 80-character alpha -numeric display • One or two Style 4 (Class "B") signaling line circuits. Style 6 (Class "A") with optional CAOM Module • Two Style Y (Class "B") regulated notification appliance circuits rated for 1.5 amp. each. Style Z (Class "A") with optional CAOM Module • Suitable for pre -action deluge applications with optional MCOM Module • Periodic trouble reminder • Individual sensor drift compensation • Dual -stage maintenance alerts ("dirty" and "very dirty") • Multilevel sensor sensitivity adjustments (front panel programmable) continued on the next page An ISO 9000-2000 Company SKMUUJW LISTED �� 0 S1669 3003549 3o7a9e nesa®.:xvmam 3074M Vol. II 1fWa®_(lIDl,ao) rn•os,a, (IIYM1na01 11 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. �@2008byHoneywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0466 Rev. E2 page 1 of 3 J Description (Continued) Remote Station, Proprietary, and Central Station fire alarm systems. It allows ample space for wiring and room for bat- teries up to 7 A/H capacity. Features (Continued) • Alarm verification per individual sensor • Positive alarm sequence for sensors or monitor modules • Four levels of system access using six (6), digit pass- words with up to five (5), user passwords per Level • Duplicate and extra address indications • March time (60 or 120 BPM)/temporal pattern/coded fours/California Code/user-defined zone coding • Cross zoning • System configuration programming and 280 event log stored in non-volatile memory • Fan restart with sequential restart delay • Upload/download of panel configuration between panel and FCP-7100 program (password protected feature) • Up to sixty-four (64), 7100 panels in the E3 Broadband network with an optional INI-7100 Module Optional Accessories LCD-7100 The LCD-7100 remote serial display offers an 80-character alphanumeric readout for the remote display of all system events. It duplicates all the information on the 7100 Series panel display and provides key switch protected functions such as System Reset, Alarm Acknowledge, Trouble Acknowledge, Signal Silence, and Drill Test. LEDs on the LCD-7100 indicate Alarm, Supervisory, Sys- tem Trouble, Power Fault, Systems Silenced, NAC#1, and NAC#2 Silenced conditions. The LCD-7100 can be surface or semi -flush mounted on a standard four -gang electrical box. It can be installed up to 4,000 feet (1,219 m) from the main control panel. The 7100 Series fire alarm control panel supports up to five (5), remote LCD-7100 annunciators using one pair of twisted, non -shielded 18 AWG min. wire or serial communication and uses another pair of 16 AWG min. for operating volt- age. (For additional information, refer to the LCD-7100 data sheet, Part Number: 9020-0486). LDM-7100 The LED Driver Module (LDM-7100) is designed to mount in a UL Listed remote annunciator and provides outputs for remote panel switches and thirty-three (33), remote LEDs. Three (3), LDM-7100 modules may be installed in a single annunciator for a total of ninety-nine (99), LEDs per annun- ciator. This combination may be repeated up to five times for a total of fifteen (15), LDM-7100 panels installed at up to five (5), different locations. Maximum distances of up to 4,000 feet (1,219 m) can be achieved using one pair of twisted, non -shielded wire for serial communication and using another pair of straight -lay wire for operating voltage. (For additional information, refer to the LDM-7100 data sheet, Part Number: 9020-0519). CAOM The Class "A" Optional Module (CAOM) allows Style Y and Z (Class "B" and "A") operation for both Notification Appli- ance Circuits and allows Style 4 and 6 (Class "B" and "A") for both Signaling Line Circuits. It also provides disconnect switches for each signaling line circuit and a common dis- connect switch for both notification appliance circuits. MCOM The Municipal Connection Option Module (MCOM) pro- vides three (3) choices of outputs. It can be configured as a Municipal Circuit (City Box) output. It may also be set to serve as a Reverse Polarity output with a nominal voltage output of 24 VDC at 0.012 amp. maximum alarm and supervisory current. The MCOM's third option provides a releasing solenoid output rated at: • 24 VDC nominal voltage. • 0.005 amp. supervisory current. • 0.710 amp. maximum alarm current. • 2 ohms maximum line resistance. PTRM The Printer Transient Module (PTRM) provides RS-232 Isolator/Transient protection for the 7100's RS-232 port (BSM connector J2). It is used in conjunction with a serial printer applied to the RS-232 port for permanent record keeping. INI-7100 The Intelligent Network Interface Module allows the 7100 Series fire alarm control panel to become the platform of a peer -to -peer, token ring, self -regenerative network com- prised of up to sixty-four (64), 7100 panels. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA - Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0466 Rev. E2 page 2 of 3 www.gamewell=fci.com Specifications Primary Input Power 120 VAC, 50/60 Hz @ 2.0 amps. or240 VAC, 50/60 Hz @ 1.0 amp. Output Power 4 amps. @ 24 VDC (total) Non-resettable Power: 1.0 amp. max. 1.0 amp. max. from both circuits Resettable Power: 1.0 amp. max. Two (2) Notification Appliance Circuits: 1.5 amp. each @ 24 VDC Current: Supervisory Alarm 7100-1 (One SLC) 0.065 amp. 0.085 amp. 7100-1 D 0.085 amp. 0.105 amp. (One SLC w/DACT) 7100-2 (Two SLC) 0.065 amp. 0.085 amp. 7100-2D (Two SLC w/DACT) 0.085 amp. 0.105 amp. LCD-7100 .012 amp. .023 amp. LDM-7100 .012 amp. .023 amp. (All LEDs lit) INI-7100-UTP,-FO 0.040 amp. 0.040 amp. Operating Temperature: 32° - 120° F (0° - 49° C) Relative Humidity: 85 % (non -condensing) Battery Charger Capacity: 31 A/H (Cabinet accommodates 12 A/H size batteries) Alarm & Trouble Relay Contacts: Form "C", 2 amps. @ 24 VDC (resistive) Ordering Information Systems Model Description 7100-1 7100 Addressable System, 1 SLC mounted in enclosure Dimensions: 19 3/8" x 19 3/8" (49 x 49 cm) Enclosure 7100-1 D 7100 Addressable FACP w/DACT, 1 SLC mounted in enclosure Dimensions: 19 3/8" x 19 3/8" (49 x 49 cm) Enclosure Basic Kits BK-7100-2 Basic System Kit, 2 SLC (BSM, Keypad Display, Transformer) BK-7100-2D Basic System Kit w/DACT, 2 SLC BK-7100-2-240V Basic System Kit, 2 SLC, 240 VAC BK-7100-2D-240V Basic System Kit w/DACT, 2 SLC Cabinets EN-7100 Enclosure (replacement) CS-7100M Metal Door (replacement) 7100-ENCL-M 7100 Enclosure Dimensions: 16.9" H x 14.4" W x 3" D 1 (43 H x 37 W x 7.7 D cm) NS-7100B Enclosure, E3 Series Broadband, NS-710OR black Enclosure, E3 Series Broadband, red Dimensions: 19 3/8" H x 19 3/8" W x 4" D (49 H x 49 W x 10 D cm) Ordering Information (Continued) Optional Modules LCD-7100 Remote Serial Annunciator, LCD Display (80-character) Dimensions: 4.25" H x 8.25" W x 1.90" (43 H x 37 W x 7.7 D cm) LDM-7100 Remote LED Driver Module Dimensions: 6" W x 4.50" (15.2 x 11.4 cm) CAOM Class A Option Combination Module with disconnect switches for both signaling line circuits and notification appliance circuits MCOM Municipal Connection Option Module for local energy city box reverse polar- ity signaling, or releasing solenoid PTRM Printer Transient Module INI-7100-FO Intelligent Network Interface Module, Fiber -Optic INI-7100-UTP Intelligent Network Interface Module, Unshielded, Twisted -Pair Replacement Parts T-7100 Transformer, 120 VAC input (replace- ment) T-7100-240 Transformer, 240 VAC input (replace- ment) BSM-7100-1 Replacement board for 7100-1 BSM-7100-1 D Replacement board for 7100-1 D GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 - Fax: (203) 484-7118 www.gamewell-fci.com 9020-0466 Rev. E2 page 3 of 3 IndependenCe- SECTION NP7-12 Heir Pbwvr✓Fud 8dut/ov+s^ e6a&WI yz-w ''�x lll N�P1-1�2` NP142FR 12V, LOU �180000' Specifications Dimensions W1- f I 65 - 1 (2.56 } 0.04) N a DIMENSIONS: MM (INCHES) Tenmina�` Availablexwith 2501"opttari• .ass t M4 ':INCH:-. MM° 060wo 250k 6 35 � . -a;85` 4.:70- 1i24: 3.15 — — 098; 2'.49 .06& A.5'2 .0:79' .020! ` `05_1, .004 0.10 A11 t .004 DIMENSIONS: (INCHES) RECOGNIZED BY UL, File No. MH 16464 NOMINAL VOLTAGE: 12V NOMINAL CAPACITY: 20 hr. rate of 0.35A to 10.50V 7.OAh 10 hr. rate of 0.65A to 10.50V 6.5Ah 15 hr. rate of 1.19A to 10.20V 5.95Ah 1 hr. rate of 4.20A to 9.60V 4.2Ah WEIGHT (approx.) 6.17 pounds (2.64 kgs.) ENERGY DENSITY (20 hr. rate): 1.49 WH/cubic inch (91.0 WH/liter) SPECIFIC ENERGY (20 hr. rate): 13.6 WH/pound (30 WH/kg) INTERNAL RESISTANCE OF CHARGED BATTERY: 30 millichms (approx.) MAXIMUM DISCHARGE CURRENT WITH STANDARD TERMINALS: 40 amperes MAXIMUM SHORT -DURATION DISCHARGE CURRENT: 210 amperes OPERATING TEMPERATURE RANGE: CHARGE 5°F to 122°F (-150C to 50°C) DISCHARGE -40F to 140°F (-20°C to 60°C) CHARGE RETENTION (shelf life) at 68OF (200C): 1 month 97% 3 months 91 % 6 months 85% LIFE EXPECTANCY: STANDBY USE 3 to 5 years CYCLE USE (approx.) 100% depth of discharge 250 cycles 50% depth of discharge 550 cycles 30% depth of discharge 1200 cycles SEALED CONSTRUCTION: Can be operated in any position without leakage. STANDARD TERMINAL: Quick Disconnect .187 or Optional .250 HOUSING MATERIAL: ABS Resin OPTIONAL: Container and cover made from Flame Retardant ABS (UL94-VO/L.O.I.>28%) WON IN III SELF DISCHARGE CHARACTERISTICS 100 75 ca s I 25 _.�.__. _.__ .. _ _ __ 20'C 18e'FI ¢ I I 40'C (104'F) � 30'C (88'F) f'".. _. ...... _.. ... — - �.---_ I 0 3 0 9 12 15 18 STORAGE TIME (MONTHS) CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE TESTING CONDITIONS: DISCHARGE CURRENT: 0.17C AMP. IRV. 1.7V/CELL) S CHARGING CURRENT: 0.09C AMP. CHARGING VOLUME: 125%OF DISCHARGED CAPACITY s (AH%) AMBIENT TEMPERATURE: 20'C TO 25-C (881F TO 771F) 120 is y 100 cs+ 0 80 r; 60 50% D.O.D. 3 e DEPTH OF DISCHARGE z � 40 i 20 0 200 400 600 800 1000 1200 1400 NUMBER OF CYCLES TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY W 120 (°b) 3, s 100 ppycA BG D� OyCP O BD W 40 1� 20 •• 301 0 - -20 -10 0 10 20 30 40 50 (°C) -24 14 32 50 68 BO 104 122 (°F) Temperature OPEN CIRCUIT VOLTAGE VS REMAINING CAPACITY IVI AT 25°C (77°F) W 14.0 13.0 L LC 12.0 fix+ 11.0 10.0 0 20 40 00 80 100 REMAINING CAPACITY (%) FLOAT SERVICE LIFE gW 7 TESTING CONDITIONS: FLOATING VOLTAGE 2.25 TO 2.30V/CELL AMBIENT TEMPERATURE: 201C TO 22% (841F TO 721F) s (AH%) it: 120 a 100 5 80 0 80 e 40 a 20 0 1 2 3 4 5 5.5 a LIFE (YEARS) When the battery will be used by the current in excess of 3L, consult with tnertiys, Inc. prior to use. CHARGING METHODS (At 200C) Cycle use: Maximum charging current 1.75A Charging voltage 14.4 to 15.OV CAUTION •Avoid short circuit Standby use: Float charging voltage 13.50 to 13.80V •Do not charge in a sealed container. Represented by: Sales Offices When ordering new batteries, also remember to properly recycle your Eastern Region: 201-964-0118 • 1-800-962-1287 old lead batteries. Federal and state regulations require lead -acid FAX 201-964-0720 batteries be recycled. EnerSys' nationwide service organization can Western Region: 562-949-4266 • 1-800-423-4667 arrange pickup, transportation to and recycling at any one of our FAX 562-949-5527 company affiliated smelters. Call 1-800-972-7372 for more information. Corporate Office: P.O. Box 14145, Reading, PA 19612-4145 FAX 610-372-8613 Visit us on the web at: www.enersysstationary.com Please check our website for literature updates Rev. - 6/01 Myc" Printed in USA FIRE CONTROL E F' ; 31 INSTRUMENTS by Honeywell Description The LCD-7100 remote serial display provides superior flexibility to the 7100 or E3 Series TM installations. It features an 80-character display which duplicates all the information on the main display with the exception of menus. The LCD-7100 contains the following function keys: • Alarm Acknowledge • System Reset/Lamp Test • Trouble Acknowledge • System Drill Test • Signal Silence A keylock must be placed in the "ON" position to enable the function keys with the exception of the "Trouble Acknowledge" key which is used to silence the trouble sounder on the LCD-7100. LEDs on the LCD-7100 are: • Alarm • System Silenced • Supervisory • NAC #1 Silenced • System Trouble • NAC #2 Silenced • Power Fault Installation The LCD-7100 can be surface or flush -mounted on a standard four -gang electrical box and installed up to 4,000 feet away from the main control. The 7100 or E3 Series TM control panels can accommodate up to five (5), remote LCD-7100 annunciators. Specifications Operating Voltage: 24 VDC (nominal) Supervisory Current: .012 amp. Alarm Current: .023 amp. Absolute Maximum Operating Temperature 32' to 120° F (0° to 49` C) Relative Humidity: 0 to 93% max., non - condensing at 90° F (32• C) Dimensions: 8 1/4" L x 4 1/2" H x 1 718" D (21 x 11 x 4.5 cm) E3 SerieSTM is a trademark of Fire Control Instruments. L011111111117160 Remote Serial LCD Display LCD-7100 Features • 80-character alphanumeric LCD display. • Full complement of function keys and LEDs. . Remote location up to 4,000 feet away from the control panel. • 7100 and E3 SeriesTM will accommodate up to five (5), annunciators. • Surface or flush -mount on a standard four -gang, electrical box. • Compact, attractive appearance. • Listed under UL Standard 864, 9th Edition. Ordering Information Model Description LCD-7100 Remote Serial LCD Display An ISO 9001-2000 Company SIGRAURG O LIM cx APPROVE[ CIIy 01 Chicagc MEA ApprO°Be City Of Approvt •Class 1 DENVER S1869 3006678 266.02-E 7300-0694 23' • Class i Approvea • High Rise GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118 Specifications are for information only, are not Intended for Installation purposes, and are subject to change without notice. No responsibility Is assumed by Gamewell-FCI for their use. 02006 Gamewell-FCI. All rights reserved. www.gamewell-fci.com 9020-0486 Rev. H page 1 of 1 MODULAR SECURITY ACCESSORIES RJ31X JACK AND CORD SETS Part # ETUL USOC R731 mo u arjae s. o p ate conductor (91.7UL) Pins. Shorting bar 1, 4, 5 and 8 UL Listed. Packaged (+91628) with matching color coded cord. 26 AWG 2ft. 8P8C to spade lugs with strain relief. (Color Header card for Display) SETUL50 Same as above with 50 microns of gold plating on (917UL50) conductor pins. Packaged with matching color coded i (+91.628) cord. 26 AWG 2ft. 8P8C with header SET (Standard) 917 + 91628 packaged with header SE.TULR2 917UL RJ3 I X Jack UL Listed. Packaged with 26 AWG (917UL) 8P8C mod to 8P8C mod straight wired cord. With (+804R2) header SET14 Standard 91.7 RJ31 X Jack packaged with a 8P4C (917) modular cord to spade lugs lft. strain relief. With (+91614) header ( Packaged ) SETULNH SETUL50NH SETNH -3- KOCK A CORD `] MODULAR SECURITY ACCESSORIES 1 USOC RJ31X JACKS 8P8C Gold plated conductor pins. Individually bagged with ;' mounting screw and doubled - sided stick tape. Made with 94VO flame retardant plastic. Shorting bar on 1, 4, 5, and 8 Ideal for security installations. UL Listed. Color Ivory. Part # 917 Standard - RJ3 l X Jack 91.7UL50 8P8C RJ31X UL Jack with 50 microns of gold 9174UL50 8P4C RJ31 X UL Jack with 50 microns oI' gold 9174A Combo 8P8C RJ31 X Jack with RJ 116P4C 917B 8P8C RJ3IX Jack 3-3/4" x 2-1/4" 916 - RJ31X CORD 8 CONDUCTOR 8P8C Round 26 AWG silver satin, plug to spade lugs. Color coded to match RJ31X Jack. Available in 1, 2, 4, and 7 ft. lengths. 91.618 -1 ft. R.13 I X cord 1 ft. 8 conductor 91648 -4ft. RJ3.1X cord 4ft. 8 conductor 91678 -7ft. RJ31 X cord 7ft. 8 conductor 1916 - RJ31X CORD 4 CONDUCTOR Modular 8P4C flat 28 AWG silver satin, plug to spade lugs. Color coded to match RJ31 X Jacl< Available in 1,2, and 7ft lengths. 91614 -1 ft. RJ31 X cord I ft. 4 conductor 91624 -2ft. RJ31 X cord 2ft. 4 conductor 91674 -7ft. RJ31X cord 7ft. 4 conductor UL CSA Available 11!!!!::::;&s'G'amewe11 FIRE CONTROL INS INSTRUMENTS by Honeywell Description The Gamewell-FCI MS-7 Style manual fire alarm stations are available in a wide variety of configurations. The Sta- tions comply with the Americans with Disabilities Act (ADA) 5-lb. maximum pull force requirement. Operating instruc- tions and Braille text are engraved in the handle. All sta- tions have a key lock/reset which is keyed alike with Gamewell-FCI fire alarm control panels and other manual fire alarm stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti® Series addressable station is a dou- ble action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.* The sta- tion features screw terminals. MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable station is a single action station designed for installation in the signal- ing line circuit of Gamewell-FCI analog addressable con- trol panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.* The sta- tion features screw terminals. The Velociti® Series stations use a communication proto- col that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and focuses on the single device. The net effect is response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action station is used with conventional - fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. Velociti® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriter's Laboratories Inc. LEXANO Is a registered trademark of GE Plastics, a subsidiary of General Electric Company. NSmIAF, MS-1 and MSmIS Non -Coded, Manual Fire Alarm Stations MS-7 Features • Addressable stations compatible with all Gamewell-FCI analog addressable fire alarm controls • Conventional stations suitable for use with any LILO Listed control panel • Both single and double action stations available • Tumbler lock for test and reset keyed alike with Gamewell-FCI controls • Surface or semi -flush mounting • Shock and vibration resistant • Stations (MS-7LOB) Listed for outdoor applications • Complies with ADA pull force requirements Only the red LED is operative in panels that do not operate in Velociti mode. An ISO 9W1-2000 Company SIGNALING &S> LISTED ApprMed MEA S240 3023594 67-02-E Vol VIII 07150-0694261 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for Information only, are not Intended for Installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. �©2008 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0616 Rev. B2 page 1 of 2 MS-7S Single Action Station The MS-7S single action station is used with conventional fire alarm control panels. It features a set of single pole contacts and wire leads for connection to an initiating cir- cuit. MS-7SP Double Action Station The MS-7SP is a double action station similar to the MS-7 station, with the additional feature of both English and Spanish instructions molded into the unit. MS-7LOB Double Action Station (Listed for Outdoor Applications) The MS-7LOB station must be mounted on a Model SB-1/0 backbox. In retrofit applications, the station is UL Listed for use with the WP-10 backbox. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS-7 interior stations may be surface mounted (use backbox SB-1/0) or semi -flush mounted on a standard dou- ble -gang, or 4-inch (10.2 cm) square electrical box. An optional trim ring (BG-TR) may also be used for semi -flush mounting. NYC -Plate The NYC -Plate provides the backplate for the manual pull station. (See Figure 1). Figure 1 NYC -Plate Specifications Material: Lexan® Contact Ratings: 0.25 amps. @ 30 VACNDC (resistive) Dimensions: 5 5/8" H x 4 1/4" W x 1 1/4" D (14 x 10.1 x 3.2 cm) Operating Temperature (MS-7AF): 32' to 120* F (0' to 49* C) Relative Humidity (MS-7AF): 10 to 93% (non -condensing) Alarm Current: .0030 amp. 0.007 for LED Supervisory Current (MS-7AF): .00030 amps. Ordering Information Model Description MS-7 Double action station. MS-7AF** Velociti addressable double action station. MS-7ASF Velociti addressable single action station MS-7S Single action station, wire leads. MS-7SP Double action station, English and Spanish instructions. MS-7LOB Double action station, outdoor use. (Must use SB-1/0 - Indoor/ outdoor use backbox). SB-1/0 Indoor/outdoor use backback- box. SB-10 Surface backbox. BG-TR. Trim ring for semi -flush mount NYC -Plate NYC backplate for manual pull station **For use with Gamewell-FCI analog addressable control panels only. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA - Tel: (203) 484-7161 - Fax: (203) 484-7118 9020-0616 Rev. B2 page 2 of 2 www.gamewell-fci.com Gam 11 ARE CONTROL INSTRUM8dT5 by Honeywell Description The Gamewell-FCI Velociti® Series, analog address- able plug-in smoke sensors with integral communica- tion provide features that surpass conventional sensors. Sensitivity can be programmed in the con- trol panel software, and is continuously monitored and reported to the panel. Point ID capability allows each sensor's address to be set, providing exact locations for selective maintenance when the cham- ber contamination reaches an unacceptable level. The ASD-PL2F photoelectric sensor's unique optical sensing chamber is engineered to sense smoke pro- duced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed -tem- perature thermal sensing on the ASD-PTL2F model. The Velociti® Series use a communication protocol that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concen- trates on the single device. The net effect is a response speed up to five times greater than earlier designs. Ordering Information Model Description ASD-PL2F Analog, addressable photoelectronic smoke sensor ASD-PTL2F Analog, addressable photoelectronic smoke sensor with thermal sensing ASD-PL2FR Analog, addressable photoelectronic smoke sensor used with the DNR duct base when the remote test is required. Velociti® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. veloeme Series ASOMPL2F, ASIM"L2F and ASImPLUR Analog, Addressable Photoelectronic ASD-PL2FIASD-PTL2F Features Smoke Sensor ASD-PL2FR • Sleek, low -profile design • Visual rotary, decimal switch addressing (01-159) • Built-in functional test switch activated by an external magnet • Bicolor LEDs flash green whenever the sensor is addressed, and light steady red on alarm' • Optional relay, isolator, or sounder bases • Low standby current • Analog addressable communication • Stable communication technique with noise Immunity • Optional remote, single -gang LED Indicator (RA400Z) • Compatible with Gamewell-FCI analog addressable panels Note: `Only the red LED is operative in panels that do not operate in Velociti® mode. An ISO 9001-2000 Company SIGNALING @<S> MEA LISTED APPApproved S1913 3023594 219-02-E Vol.VI 7272.1703:121 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change vnthout notice. No responsibility is assumed by Gamewell-FCI for their use. ©2010 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0617 Rev. H page 1 of 2 i Installation ASD-PL2F plug-in sensors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove sensors without using a ladder. ❑ ount the base on a box which is at least 1.5C(3.8 cm) deep. Suitable mounting base boxes include: • 4.0❑(10.2 cm) square box • 3.5C(8.9 cm) or 4.00(10.2 cm) octagonal box • Single -gang box (except relay or isolator bases) • ❑ ith B200SR base, mounted on a 4.00(10.2 cm) square box • ❑ ith B224RB or B224BI base, mounted on a 3.5❑ (8.9 cm) octagonal box, or a 4.00(10.2 cm) octagonal or square box ❑O❑❑CBecause of the inherent supervision provided by the SLC, end -of -line resistors are not required. ❑ iring CT-taps❑or branches are permitted for Style 4 (Class CBC) wiring. Censor ❑pacing Gamewell-FCI recommends that the spacing sensors be used in compliance with NFPA 72. ❑pecifications ❑iCe❑ 2.1 C(5.1 cm) high x 4.1 C(10.4 cm) diameter installed in the B501 base, ❑1❑(15.5 cm) diameter installed in the ADB-FL base. ❑Gipping ❑ eig❑tC5.2 o❑ (147 g) Operating Cemperature❑ ASD-PL2F: 32° F to 120' F (0' C to 49° C) ASD-PTL2F: 32°Fto100°F(0°Cto31°C) ❑❑®EEisted Celocit❑ ❑ange❑ 0-4000 ft.l-min. (1,219.2 mCmin.), suitable for installation in ducts. ❑elati❑e ❑umidit❑❑ 10-9311 (non -condensing) ❑Cermal ❑atings❑Fixed-temperature setpoint 135° F (57° C) ❑lectrical ❑pecifications Coltage ❑ange❑ 15 032 volts DC peak ❑tend❑❑❑urrent❑(max. avg.):.0003 A ❑ 24 VDC (one communication every 5 seconds with LED enabled) MaCimum ❑farm ❑urrent❑ O005 A ❑ 24 VDC (LED) lit). ❑ases and Options ❑D❑[F❑ D. 1 C(15.5 cm) diameter ❑❑❑❑❑❑ ❑❑75C(17.46cm) Base Diameter 2.00(5.08 cm) Base ❑eight ❑ DEED 0 ❑ela❑ ❑ase Screw terminals. - Op to 14 A❑ G (2.0 mm2) Relay type: Form-C Rating: 2.OA ❑ 30 VDC resistive❑ 0.3 A ❑ 110 VDC inductive❑ 1.0 A ❑ 30 VDC inductive. Dimensions: ❑2Cx 1.2❑(15.7 x 3.0 cm) MaCimum❑25 devices between isolator bases. ❑❑DOD Remote alarm indicator, LED. ❑❑❑=❑ Black detector covers (box of 10) D❑❑ Duct smoke housing ❑❑M❑❑ ❑❑❑[F❑1 12 Clintonville Road, Northford, CT OC472-1 C53 ❑SA • Tel: (203) 4C4-71 G1 • Fax: (203) 4C4-711 ❑ 9020-0D17 Rev. 0 page 2 of 2 ❑❑❑[game❑ell[fci1com INTELLIGENT LOW PROFILE SENSORS MIX-200 SERIES Mircom's MIX-200 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors. Detector sensitivity is continuously monitored and reported to the FX-2000 Fire Alarm Control Intelligent Low Profile Ionization Smoke Sensor (MIX-1251 B) The Intelligent Ionization Smoke Sensor is constantly monitored to measure any change in its sensitivity due to the environment (dirt, aging, temperature, humidity, etc.) It can give an advance indication to the FX-2000 analog control panel of the need for maintenance and can be specific as to where the maintenance is needed. It can be mounted in a number of dfferent bases. See the Ordering Information for a list of these bases and their descriptions. Intelligent Thermal Sensors (MIX-5251 B/MIX-5251 RB/MIX-5251 H) The Intelligent Thermal Sensors contain a dual thermistor sensing circuit for fast response. They provide open area protection with 50 foot spacing. The sensors rapid response characteristic virtually eliminates the thermal lag which is characteristic of conventional heat detectors and insures operation as soon as the temperature reaches its set point (MIX-5251 B), or upon a temperature rise of 15°F per minute (MIX-5251 RB). The MIX-5251 H provides fixed high temperature detection at 190OF. These sensors can be mounted in a number of different bases. See the Ordering Information for a list of these bases and their descriptions. Panel. Point ID capability allows each detector's address to be set with decade address switches, providing exact detector locations for selective maintenancewhen chamber contamination reaches an unacceptable level. Intelligent Low Profile Photoelectronic Smoke Sensor (MIX- 2251 B) The Intelligent Photoelectronic Smoke Sensor is constantly monitored to measure any change in its sensitivity due to the environment (dirt, aging, temperature, humidity, etc.) It can give an advance indication to the FX-2000 analog control panel of the need for maintenance and can be specific as to where the maintenance is needed. It can be mounted in a number of dfferent bases. See the Ordering Information for a list of these bases and their descriptions. Intelligent Low Profile Photoelectronic Smoke Sensor with Thermal (MIX-2251TB) The MIX-2251TB has the same features as the MIX- 2251 B and includes a 135DF thermal sensor. It can be mounted in a number of different bases. See the Ordering Information for a list of these bases and their descriptions. ® ' M EA SFM ed 2151 approved (MIX.1251B) 2131 S6295 (MIX-12518. CS920 (MIX-1251B, 7271-1477:122 (MIX-12518) ' 14M3-E (MIX-12518) (MIX-2251a TB) MIX-2251B B MIX-22518 S 7271-1477:117 219-02-E F M MIX-2251 T8) S6299 MIX-2251 TB) CS717 (MIX-2251BM) 7271-1477:114 (MIX-22518/TB) 390-02-E nvvnoveD (MIX-525iama'H) (MIX-52'51a Ra H) (W-52518/Ralk) (MIX-5251BiRBM) 3017996 CATALOGUE NUMBER 5904 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice In prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Specifications Height 2.0 inches (51 mm) Diameter 6.1 inches (155 mm) Installed in B21OLP Base 4.1 inches (104 mm) Installed in B501 Base Shipping Weight Heat: 4.8 oz. (137 g) Photo/Photo with Heat: 5.2 oz. (147 g) Ion: 5.4 oz. (154 g) Operating Temperature Range Ion/Photo: 32*F to 120*F (0°C to 49°C) Photo with Thermal: 32°F to 100°F (0°C to 38°C) Thermal: -4*F to 100*F (-20oC to 38*C) High Temperature: -4°F to 100°F (-20oC to WC) UL Listed Velocity Range Ion: 0 - 1200 fpm (0 - 5.1 m/sec) Photo/Photo with Thermal: 0 - 4000 fpm (0 - 20 m/sec) Relative Humidity 10% - 93% noncondensing Insect Screen Hole Size Photo: 0.016 inch (0.41 mm) nominal Ion: 0.035 inch (0.89mm) nominal Thermal Ratings Fixed Temperature Setpoint: 135*F (57°C) Rate of Rise Detection: 15°F/min. (8.3*C/min.) High Temperature: 190*F (88*C) Voltage Range 15 - 32 volts DC peak Standby Current lon/Thermal: 150 uA @ 24 VDC (without communication, LED off) 200 uA @ 24 VDC (one communication every 5 sec. with LED enabled) Photo/Photo with Thermal: 250 uA @ 24 VDC (without communication, LED off) 300 uA @ 24 VDC (one communication every 5 sec. with LED enabled) LED Current (max.) 6.5 mA @ 24 VDC (on) Note: Mounting sensors outside of the specified temperature ranges will cause sensor failures and erratic panel operation. Ordering Information Model Description Intelligent Addressable Analog Sensors MIX-1251B Intelligent Low Profile Ionization Smoke Sensor MIX-2251B Intelligent Low Profile Photoelectronic Smoke Sensor MIX-2251TB Intelligent Low Profile Photoelectronic Smoke Sensor c/w 135°F Fixed Temp. Thermal Sensor MIX-5251 B Intelligent Low Profile Fixed Temp. Thermal Sensor 135*F MIX-5251 RB Intelligent Low Profile Fixed Temp. and Rate of Rise Thermal Sensor 135*F MIX-5251 H Intelligent Low Profile High Temperature Thermal Sensor 190°F Intelligent Analog Bases b224bl Intelligent Isolator base B224RB Intelligent Relay Base* B501 Intelligent Flangeless Mounting Base B501 BH Intelligent Sounder Base 8501 BHT Intelligent Temporal Tone Sounder Base Accessories RA-40OZ Remote LED Annunciator Note: For Canadian models add suffix A". * When used with the M50OX Fault Isolator Module, the number of relay bases between fault isolators is limited to 12. NOT TO BE USED FOR INSTALLATION PURPOSES. Canada U.S.A. 25 Interchange Way 60 Industrial Parkway Vaughan, Ontario L4K 5W3 Cheektowaga, New York 14227 Telephone: (905) 660-4655 Toll Free: (888) 660-4655 Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Web page: http://www.mircom.com Email: mail@mircom.com CAT. 5904 Rev. 5 ff FIRE CONTROL INSTRUMENTS DESCRIPTION The FCI FM series electromagnetic door releases hold fire and smoke barrier doors open until released by a remote smoke detector switch, fire alarm control or sprinkler sys- tem. In the event of power failure, doors are released to close automatically, but may be opened or closed manually at any time. The door holders have a sprayed aluminum finish. All models feature a "multi -voltage" design, allowing them to operate on 12 VDC, 24 VAC/DC, or 120 VAC, thus sim- plifying both installation and inventory. POWER REQUIREMENTS Voltage Current 12 VDC .040 amp. 24 VAC/DC .020 amp. 120 VAC .020 amp. FM SERIES ELECTROMAGNETIC DOOR RELEASE FEATURES APPROVALS • Fail -Safe Operation • Approx. 35 lbs. (15.9 kg) Holding UL Listed R4869 Power C.S.F.M. 3550-0047:001 • Positive Release Button to Initiate NYC BS&A 287-77-SA Closing Motion when the Electromagnet is De -Energized ORDERING INFORMATION Part Number Model Description Total projection from wall 140-90000 FM-980 Floor mount N/A 140-90001 FM-981 Floor mount, double doors N/A 140-90002 FM-990 Low profile mount 1 7/8 in. (4.9 cm) 140-90003 FM-996 Surface Mount 4.12 in. (10.05 cm) 140-90004 FM-997 Recessed mount 2.6 in. (5.35 cm) 140-90005 FM-998 Recessed, concealed wiring 2.6 in. (5.35 cm) Specifications are provided for information only, are not intended to be used for installation purposes, and are believed to be accurate. ❑owever, no responsibility is assumed by Fire Control Instruments, Inc. for their use. Specifications subfect to change without notice. ❑ 1997 All Rights Reserved 301 2nd Ave Waltham, MA 02451-1133 USA TEL: (781) 487-0088 FAX: (781) 370-4132 9020-0045/Ver. 1.3 _ Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The Gamewell-FCI, HPFF8 is a Notification Appliance Cir- cuit (NAC) expansion panel designed to extend the power capabilities of existing NACs and provide power for auxil- iary devices. The HPFF8 connects to any 12 or 24V Fire Alarm Control Panel (FACP) or stand alone. Available in 8.0 amps, they provide regulated and filtered 24VDC power to each of the four NACs and an auxiliary output. The NAC outputs are rated at 3.0 amps each (the total output cannot exceed 8.0 amps). The auxiliary output is rated at 2.0 amps. This output is continuously supplied, even in alarm, and therefore must be taken into account for power supply loading and battery size calculations. The NAC outputs may be configured as any of the follow- ing: • Four Class B (Style Y) • Two Class A (Style Z) • Two Class B and one Class A • Four Class A with the optional HPP31076 Class A adapter installed These power supplies contain an internal Battery charger capable of charging up to 26.0 amp -hour (AH) batteries. The HPFF8 is mounted in lockable wall cabinet units that can accommodate up to two 18AH batteries. A multipack option allows for up to four chassis mount units installed in a single lockable SBB-D4 enclosure. These chassis mount units have a "CM" suffix, HPFF8CM and can accommo- date two 12AH batteries. Power supplies are available in either 120VAC/60 Hz or 240VAC/50 Hz. One of the most challenging aspects of a retrofit applica- tion is locating the existing End -of -Line (EOL) resistor. In these applications that have EOL values, other than the 3.9k normally used with the HPFF8, a single resistor matching the existing EOL can be used as a reference for all the outputs. This feature speeds the installation and the system checkout, because the actual EOL does not need to be located and changed in the circuit. The reference resistor must be within the range of 1.9k to 25k. xrFF8 NAC Expander/Power Supply HPFF8 Features • Four (4) supervised notification application circuits (NACs) capable of supplying +24VDC at 3.0 amp maximum each • NAC output circuits may be configured as any of the following: - Four Class B (Style Y) - Two Class B & one Class A - Two Class A (Style Z) - Four Class A with the optional HPP31076 Class A adapter installed • Four field -programmable operational modes • 2.0 amp auxiliary continuously supplied output • Two fully supervised input/output control circuits • Temporal coding and sync protocols compatible with the following notification appliance brands: - System Sensor - Faraday - Gamewell - Amseco - Cooper -Wheelock - Gentex • Supervised AC input, battery voltage, auxiliary output, charger, and earth ground faults • Trouble indication for supervision of the following: - NAC circuits - Auxiliary output - AC input - Charger - Battery voltage - Open contacts in the initiat- - Earth ground faults by ing device signal inputs (for individual status LED's FACP trouble notification) • Separate Trouble and AC Fail Form-C relay Contacts • •111 111 � •: GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2009 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60521 Rev. B page 1 of 2 Features (Continued) • The Trouble Form-C relay contacts selectable for imme- diate or a 2 hour delay with AC failure • 26 AH battery charger capability; the wall cabinet supports two 12V 18AH batteries, while the multi -pack equipment cabinets supports two 12V 12AH batteries. • NAC Overload protection and indication • Up to four chassis mount units (HPFF8CM) can be installed in the SBB-D4 backbox • Wall mount units can be configured to internally house the following: - one AOM-2SF single control module - one AOM-2R single relay module Specifications Primary Input Power: 120VAC/60Hz, 3.OA or 220VAC/50Hz, 1.5A Secondary Power: 24 volt operation: two (2), 7-24 AH batteries Battery Charging Capacity: Up to 26 AH batteries mounted Battery Space: HPFF8 Cabinet: SBB-D4 Cabinet: Total Output Power: Standby Current: Auxiliary Power Output: Up to two 18AH batteries Up to two 12AH batteries per supply 8.OA max 0.030 A 0.15A under all conditions 2.OA if load is removed dur- ing operation (external relay or AC Fail Relay is required) Specifications (Continued) NAC Output Ratings: 24VDC fully regulated, 3.OA End -of -Line Resistor Range: Common Trouble Relay/AC Fail Relay: Input Control Circuit: Temperature Rating: Relative Humidity: Cabinet Dimensions: HPFF8 Cabinet: SBB-D4 Cabinet: max per circuit (8.OA total) 2K to 25k ohm, Yz watt 2.OA at 28VDC or 120VAC 16-30VDC @ 5mA min. 32°F to 120°F (0°C to 49°C 10% to 93% non -condensing 16.65" W x 19.0" H x 5.2" D (42.29 W x 48.26 H 13.23 D cm) 24" W x 45.9" H x 5.15" D (60.96 W x 116.52 H x 13.1 D cm) Ordering Information Part Number Description HPFF8 8A fire rated power supply operating at 120VAC/60 Hz. Unit includes red enclosure with HPP lock and key HPFF8CM 8A fire rated power supply - chassis mounted operating at 120VAC/60 Hz. Unit includes mounting hardware for installation in the SBB-D4 enclosure HPFF8E 8A fire rated power supply operating at 240VAC/50 Hz HPFF8CME 8A fire rated power supply chassis mounted operating at 240VAC/50 Hz HPP31076 Class A (Style Z) NAC module FCI-VDR-D4 Vented door, PK-625 lock and key for SBB-D4 backbox, black SBB-D4 Backbox, accepts up to 4 chassis, black GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA - Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60521 Rev. B page 2 of 2 www.gamewell-fci.com SECTION NP7-12 Inde enT- - eer P�Dwvr/FuU udciuor�,s^ YllASA NPI-12 NPI-12FR 12V, LOU 1SOs000Specifications Dimensions 65 ± 1 (2.56 ± 0.04) oS 00 +H +A P Q� DIMENSIONS: MM (INCHES) Terminal Available ,with .250'opti0n: JU t M4 ANCH- =AM 060 250: .1% 4.;7Q' a .1,24 , _116- 7098, a2.49, 060` - x:1.52.' ' .,Q3if ©J,4 ©20! 0 5f mitDW DIMENSIONS: (INCHES) Iova RECOGNIZED BY UL, File No. MH 16464 NOMINAL VOLTAGE: 12V NOMINAL CAPACITY: 20 hr. rate of 0.35A to 10.50V 7.OAh 10 hr. rate of 0.65A to 10.50V 6.5Ah 15 hr. rate of 1.19A to 10.20V 5.95Ah 1 hr. rate of 4.20A to 9.60V 4.2Ah WEIGHT (approx.) 6.17 pounds (2.64 kgs.) ENERGY DENSITY (20 hr. rate): 1.49 WH/cubic inch (91.0 WH/liter) SPECIFIC ENERGY (20 hr. rate): 13.6 WH/pound (30 WH/kg) INTERNAL RESISTANCE OF CHARGED BATTERY: 30 milliohms (approx.) MAXIMUM DISCHARGE CURRENT WITH STANDARD TERMINALS: 40 amperes MAXIMUM SHORT -DURATION DISCHARGE CURRENT: 210 amperes OPERATING TEMPERATURE RANGE: CHARGE 50F to 1220F (-15°C to 50°C) DISCHARGE -4°F to 140OF (-20°C to 60°C) CHARGE RETENTION (shelf life) at 68OF (201C): 1 month 97% 3 months 91 % 6 months 85% LIFE EXPECTANCY: STANDBY USE 3 to 5 years CYCLE USE (approx.) 100% depth of discharge 250 cycles 50% depth of discharge 550 cycles 30% depth of discharge 1200 cycles SEALED CONSTRUCTION: Can be operated in any position without leakage. STANDARD TERMINAL: Quick Disconnect .187 or Optional .250 HOUSING MATERIAL: ABS Resin OPTIONAL: Container and cover made from Flame Retardant ABS (1-11-94-VO/L.O.I.>289%) 4 NINE _ .I Mills N,l is �Il11'lil 1 It 11mgasom IMME11IN SELF DISCHARGE CHARACTERISTICS 1%) 100 ca 75 ct z W - 20-C (SB'F) 10'C (104°F) �311`C(Wfl 25 _— 0 3 6 9 12 15 18 STORAGE TIME (MONTHS) CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE TESTING CONDITIONS: DISCHARGE CURRENT: 0.17C AMP. (F.V. 1.7V/CELL) s CHARGING CURRENT: 0.09C AMP. CHARGING VOLUME: 125%OF DISCHARGED CAPACITY s(AH%) AMBIENT TEMPERATURE: 20-C TO 25-C (88'F TO 77'F) 120 a 1B0 c`a O 80 60 z 40 o: a 20 0 DEPTH 200 400 Boo 800 1000 1200 1400 NUMBER OF CYCLES TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY (%) 120 i ,t 100 p�A 4a 1cA p�C S � 3CA O -20 _10 0 10 20 30 40 so (•C) —24 14 32 50 68 Be 104 122 ("F) TernDe°at� OPEN CIRCUIT VOLTAGE VS REMAINING CAPACITY (V) AT 25°C (77°F) W 14.0 13.0 m x z a ! I o � i 10.0 0 20 40 0o Bo 100 REMAINING CAPACITY I[ ) FLOAT SERVICE LIFE W 3 TESTING CONDITIONS: FLOATING VOLTAGE 2.25 TO 2.30V/CELL AMBIENT TEMPERATURE: 20'C TO 22'C (641 TO 721F) s (AH%( 128 a 100 SO O 60 CO 40 z 20 W 0 1 2 3 4 5 5.5 LIFE (YEARS) Wnen the battery will be useo by the Current In excess OT JU, consult wan tner sys, inc. prior to use. CHARGING METHODS (At 20°C) Cycle use: Maximum charging current 1.75A Charging voltage 14.4 to 15.OV CAUTION •Avoid short circuit Standby use: Float charging voltage 13.50 to 13.80V *Do not charge in a sealed container. Represented by: Sales Offices When ordering new batteries, also remember to properly recycle your Eastern Region: 201-964-0118 • 1-800-962-1287 old lead batteries. Federal and state regulations require lead -acid FAX 201-964-0720 batteries be recycled. EnerSys' nationwide service organization can Western Region: 562-949-4266 • 1-800-423-4667 arrange pickup, transportation to and recycling at any one of our FAX 562-949-5527 company affiliated smelters. Call 1-800-972-7372 for more information. Corporate Office: P.O. Box 14145, Reading, PA 19612-4145 FAX 610-372-8613 ISO n 9000 us on the web at Please for www.enersysstationarycom literature Rev. - 6/01 pECYCLE ase check our website updates Printed in USA FIRE CONTROL INSTRUMENTS U31 Building Intelligent Networks wwwfimcontrolinstruments.com GENERAL The FCI Series intelligent plug-in thermal detectors with integral communication provide features that surpass conventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with decade address switches, providing exact detector locations for selective maintenance when chamber contamination reaches an unacceptable Ievel.ATD Series thermal detectors use an innovative thermistor sensing circuit to produce 135°F/57°C fixed - temperature (ATD-L2) and rate -of -rise thermal detection (ATD-RL2) in a law -profile package.TheATD-HL2 provides fixed high - temperature detection at 190°F/88°CThese thermal detectors provide cost effective, intelligent property protection in a variety of applications. INSTALLATION ATD-1_2 plug-in detectors use a separate base to simplify installation, service, and main- tenance.A special tool allows maintenance personnel to plug in and remove detectors without using a ladder. Mount base on a box which is at least 1.5" (3.81 cm) deep. Suitable mounting base boxes include: • 4.0" ( 10.16 cm) square box. • 3.5" (8.89 cm) or 4.0" (10.16 cm) octago- nal box. • Single -gang box (except relay or isolator base). • With B501 BH base, use a 4.0" (10.16 cm) square box. • With B224RB or B224B1 base, use a 3.5" (8.89 cm) octagonal box, or a 4.0" (10.16 cm) octagonal or square box. NOTE: Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required.Wiring" Ttaps" or branches are permitted for Style 4 (Oass`rB") wiring. FEATURES AT842 ANALOGADDRESSABLE THERMAL DETECTOR • Sleek, low -profile, stylish design. • State-of-the-art thermistor technology for fast response. • Rate -of -rise model (ATD-RL2), 157 (8.3°C) per minute. • Factorypreset at 1357 (57°C), high - temperature modelATD-HL2 at 190°F (88°C). • Addressable by device. • Rotary 0 1 — 99 address switches • Two -wire loop connection. • Visible LEDs "blink" eve ry time the unit is polled. • 360°-field viewing angle of the visual alarm indicators (Two red LEDs). LEDs blink in Normal condition and turn on steady inAlarm. • Integral communications and built-in device -type identification. • Remote test feature from the panel. • Built-in functional test switch activated by external magnet. • Low standby current. • Listed to UL 52 I. • Built-in tamper -resistant feature. • Designed for direct -surface or electrical -box mounting. • Sealed against back pressure. • Plugs into separate base for ease of installation and maintenance. Separate base allows interchange of photoelec- tric, ionization and thermal sensors. • SEMS screws for wiring of the separate base. • 94-5V plastic flammability rating. • Remote LED output connection to optional RA40OZ remote LED annunciator. • Optional sounder, relay, and isolator bases. ATD-L2 R NVA l 4' 1 FM APPROVED t57 `tERVICE An ISO 9001 ComDan Specifications areprovided for information only,and are not intended to be used for installation purposes and are believed to be accurate. However no responsibility is assumed by Fire Control Instruments for their use. Specifications subject to change without notice. a 2003 All Rights Reserved 9020-0560Ner.1.0 Page 1 of 2 A Honeywell Company FIRE CONTROL INSTRUMENTS K042 Building Intelligent Networks wwwfirecontrolinstruments.com REMOTE ANNUNCIATOR + F ------- I — +-----------i I I I I Listed Compatible I CONTROL 3 V2 3 2 PANEL I l I I I I I I I I I I I I ------------------------------------------ I OPTIONAL RETURN LOOP ------------------------------------------------------- SPECIFICATIONS Size:2. l" (5.1 cm) high x 4.1" (10.4 cm) diameter installed in B501 base,6.1 " (15.5 cm) diameter installed inADB-FL base. Shipping weight: 4.8 oz. (137 g). Operating temperature range: ATD-L2,4TD-RL2: —20°C to 38°C (-4°F to 100°F);ATD-HL2: —20°C to 66°C (-4°F to 150°F). Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. Relative humidity: 10% — 93% noncondensing. Thermal ratings: fixed -temperature setpoint 135°F (57°C), rate -of -rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C). ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak. Standby current (max. avg.): 200 pA @ 24VDC (without communication);300 pA @ 24VDC (one communication every 5 seconds with LED enabled). LED current (max.): 6.5 mA @ 24VDC ("ON ").Voltage range: 15 - 32 volts DC peak. BASESAVAILABLE ADB-FL 6.1 " (15.5 cm) diameter. B501: 4.1 " (10.4 cm) diameter. B501BHorB50IBHT. Sounder base assembly (B501 BHT produces aTemporal Pattern). Includes B501 base. B224RB Relay Base: Screw terminals: up to 14AWG (2.0 mm2).Relay type: Form-C.Rating. 2.OA @ 30VDC resistive; 0.3A @ I I OVDC inductive; LOA @ 30VDC inductive. Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm). B524BI Isolator Base: Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm). Maximum: 25 devices between isolator bases. Specifications are provided for information only, and are not intended to be used for installation purposes and are believed to be accurate. However. no responsibility is assumed by Eire Control Instruments for their use. Specifications subject to change without notice. 02003AII Rights Reserved FIRE CONTROL INSTRUMENTS 16 Southwest Par k,Westwood,MA02090 USA • Tel:781-471-3000 • Fax:781-471-3099 • www.firecontrolinstruments.com A Honeywell Company 9020-0560NER.I.0 / Page 2of2 Gamewell FIRE CONTROL INS INSTRUMENT by Honeywell Description The Gamewell-FCI Velociti® Series, addressable output relay control module (AOM-2RF) allows an Gamewell-FCI analog addressable fire alarm control to switch discrete relay contacts by code command. The relay provides two (2), isolated sets of Form-C contacts which transfer simul- taneously. Circuit connections to the relay contacts are not supervised by the module. The Velociti® Series use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The AOM-2RF Module is designed for installation in the signaling line circuit of any Gamewell-FCI analog address- able fire control panel. The module contains a panel con- trolled LED. The AOM-2RF is designed to mount in a 4" square junction box 2 1/8" deep. Relay Contact Ratings Current Rating Maximum Voltage Load Description Application 3A 30 VDC Resistive Non -Coded 2A 30 VDC Resistive Coded 0.9A 110 VDC Resistive Non -Coded 0.5A 125 VAC Resistive Non -Coded 0.5A 30 VDC Inductive (UR=5ms) Coded 1A 30 VDC Inductive (UR=2ms) Coded 0.5A 125 VAC Inductive (PF=.35) Non -Coded 0.7A 75 VAC Inductive Non -Coded Velociti® Series is a registered trademark of Honeywell Intemational Inc. velocitio Series A8111=21F Addressable Output Relay ACM-2RF Features Control Module • Two (2) sets of Form "C" contacts • Visual rotary, decimal switch addressing (01-159) • Bicolor LEDs flash green whenever the sensor is addressed, and light steady red on alarm' • Compact size allows easy installation Note: Only the red LED is operative in panels that do not operate in Velociti® mode. Specifications Supervisory current: Alarm current: Operating temperature Relative humidity: Dimensions .000375 amps. .0065 amps. 32° to 120' F (0' to 49° C) 10 to 93% relative humidity (non -condensing) 4 1 /2" H x 4" W x 1 1 /4" (11.4 x 10.2 x 3.2 cm) Ordering Information Model Description AOM-2RF Addressable output relay control module An ISO 9001-2000 Company SIGNAUNG t UL FM MEA LISTED APPROVED Approved S1949 3023594 227-03-E Vol. 07300-0694:178 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. \ ©2011 Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0625 Rev. D1 page 1 of 1 SpectrAlert Advance119110 AID I PPoM' Selectable Output Notification Appliances by Honeywell General SpectrAlert Advance selectable -output horns, strobes and horn/strobes are rich with features guaranteed to cut installa- tion times and maximize profits. The SpectrAlert Advance series of notification appliances is designed to simplify your installations, with features such as: plug-in designs, instant feedback messages to ensure correct installation of individual devices, and eleven field -selectable candela settings for wall and ceiling strobes and horn/strobes. More specifically, when installing Advance products, first attach a universal mounting plate to a four -inch square, four - inch octagon, or double -gang junction box. The two -wire mounting plate attaches to a single -gang junction box. Then, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe, or horn/strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the prod- uct's pins into the mounting plate's terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. SpectrAlert Advance products allow you to choose: • 12 or 24 volts. • At 24 volts, 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, or 185 candela by way of rear -mounted slide switch and front viewing window. • Horn tones and volume by way of rotary switch. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two -wire and four -wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between —40°F and 151°F (-40°C and 66°C) in wet or dry applications. Models available: • Indoor wall -mount: horn, strobe, 2-wire horn/strobe, 4-wire horn/strobe. • Indoor ceiling -mount: strobe, 2-wire horn/strobe, 4-wire horn/strobe. • Outdoor wall -mount: horn, strobe, 2-wire horn/strobe, 4- wire horn/strobe. • Outdoor ceiling -mount: strobe, 2-wire horn/strobe, 4-wire horn/strobe. Features • Plug-in design. • Same mounting plate for wall- and ceiling -mount units. • Shorting spring on mounting plate for continuity check before installation. • Captive mounting screw. • Tamper -resistance capability. • Field -selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. • Automatic selection of 12 or 24 volt operation at 15 and 15/ 75 candela. • Outdoor wall and ceiling products. • Outdoor products rated from —40°F and 151°F (-40°C and 66•C). 7087phol.jpg Indoor Ceiling Horn/Strobe 7087pho3.jpg p ' pl p ;0 Indoor Wall Horn/Strobe 7087pho5.jpg Indoor Wall Horn 7087pho2 jpg Outdoor Ceiling Strobe 7087pho41pg Indoor Ceiling Strobe Outdoor Wall Strobe • Minimal intrusion into the backbox. • Horn rated at 88+ dbA at 16 volts. • Rotary switch for tone selection. • Three horn volume settings. • Electrically compatible with existing SpectrAlert products. Engineering Specifications SpectrAlert Advance horns, strobes, and horn/strobes shall mount to a standard 4.0" x 4.0" x 1.5" (10.16 x 10.16 x 3.81 cm) backbox, 4.0" (10.16 cm) octagonal backbox, or a double - gang backbox. Two -wire products shall also mount to a single - gang 2.0" x 4.0" x 1.875" (5.08 x 10.16 x 4.763 cm) backbox. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit7l' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and 120•F (0•C and 49°C) from a CS-2539 • 09/01/06 — Page 1 of 4 regulated DC, or full -wave -rectified, unfiltered power supply. Strobes and horn/strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. STROBE The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appli- ances, flashing at 1 Hz over the strobe's entire operating volt- age range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. HORN/STROBE COMBINATION The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a Temporal 3 pattern and a Non - Temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn/ strobe models shall operate on a coded or non -coded power supply. OUTDOOR PRODUCTS SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between —40°F and 151°F (-40°C and 66°C). The products shall be listed for use with a System Sensor outdoor/weather- proof backbox with half -inch and three -fourths -inch conduit entries. SYNCHRONIZATION MODULE The module shall be a System Sensor Sync -Circuit listed to UL 464 and shall be approved for fire protective ser- vice. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at Temporal 3. Also, while operating the strobes, the Strobe ❑urrent Dra❑❑ ❑❑ ❑ a[i❑u❑ ®A ❑❑ S❑ Candela 8-17.6V 16-33V DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15175 142 148 77 81 30 NA N/A 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Page 2 of 4 — CS-2539 • 09101106 module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 4.688" x 4.688" x 2.125" (11.906 x 11.906 x 5.398 cm) backbox. The module shall also control two Style Y (class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multi- ple zones. Daisy -chaining two or more synchronization mod- ules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Operating Specifications Standard operating temperature: 32°F to 120°F (0°C to 49°C). K Series operating temperature: —40oF and 151 °F (-40oC and 66°C). Humidity range: 10% to 93% non -condensing (indoor prod- ucts). Strobe flash rate: 1 flash per second. Nominal voltage: regulated 12 VDC/FWR or regulated 24 VDC/FWR. NOTE: Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. Operating voltage range: 8 V to 17.5 V (12 V nominal); or 16 V to 33 V (24 V nominal). NOTE: P, S, PC, and SC products will operate at 12 V nominal only for 15 cd and 15175 cd. Input terminal wire gauge: 12 to 18 AWG (3.31 to 0.821 mmz). Ceiling -mount dimensions (including lens): 6.8" diameter x 2.5" deep (17.3 cm diameter x 6.4 cm deep). Wall -mount dimensions (including lens): 5.6" H x 4.7" W x 2.5" D (14.2 cm H x 11.9 cm W x 6.4 cm D). Horn dimensions: 5.6" H x 4.7" W x 1.3" D (14.2 cm H x 11.9 cmWx3.3cmD). Agenc❑❑istings and Approvals The listings and approvals below apply to SpectrAlert Advance Selectable Output Notification Devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing sta- tus. • UL Listed: file ❑orn ❑urrent Dra❑❑ ❑❑ ❑ aCi❑u❑ mA [I El S❑ Sound Pattern dB 8-17.5V 16-33V DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non -temporal High 57 56 69 75 Non -temporal Medium 42 50 60 69 Non -temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 ❑orn and Dom/Strobe ❑otar❑S❑itc❑Setting❑ ❑orn and Dom/Strobe Output EdUA❑ Setting Repetition Rate dB Level 1 Temporal horn High 2 Temporal horn Medium 3 Temporal horn Low 4 Normal horn High 5 Normal horn Medium 6 Normal horn Low 7' Externally coded High 8' Externally coded Medium 9' Externally coded Low *NOTE: Settings 7, 8, and 9 are not available on 2-wire horn/strobe. Switch Position Sound Pattern dB 8-17.5V 16-33V DC FWR DC FWR 1 Temporal High 78 78 84 84 2 Temporal Medium 74 74 80 80 3 Temporal Low 71 73 76 76 4 Non -temporal High 82 82 88 88 5 Non -temporal Medium 78 78 85 85 6 Non -temporal Low 75 75 81 81 7' Coded High 82 82 88 88 8* Coded Medium 78 78 85 85 9* Coded Low 75 75 81 81 *NOTE: Settings 7, 8, and 9 are not available on 2-wire horn/strobe. ®o® ire ❑orn/Strobe[STANDARD Candela Range (15 — 115 cd), UL Maximum Current Draw (mA RMS) Input, Sound Pattern, dB Level 8-17.5V 16-33V 15 15/75 15 15/75 30 75 95 110 115 DC Input, Temporal, High 137 147 79 90 107 176 194 212 218 DC Input, Temporal, Medium 132 144 69 80 97 157 182 201 210 DC Input, Temporal, Low 132 143 66 77 93 154 179 198 207 DC Input, Non -temporal, High 141 152 91 100 116 176 201 221 229 DC Input, Non -temporal, Medium 133 145 75 85 102 163 187 207 216 DC Input, Non -temporal, Low 131 144 68 79 96 156 182 201 210 FWR Input, Temporal, High 136 155 88 97 112 168 190 210 218 FWR Input, Temporal, Medium 129 152 78 88 103 160 184 202 206 FWR Input, Temporal, Low 129 151 76 86 101 160 184 194 201 FWR Input, Non -temporal, High 142 161 103 112 126 181 203 221 229 FWR Input, Non -temporal, Medium 134 155 85 95 110 166 189 208 216 FWR Input, Non -temporal, Low 132 154 80 1 90 1 105 161 184 1 202 211 Two -Wire Horn/Strobe, HIGH Candela Range (135 — 185 cd), UL Maximum Current Draw (mA RMS) DC Input 16-33V FWR Input 16-33V 136 150 177 185 135 150 177 185 DC, Temporal, High 245 259 290 297 FWR, Temporal, High 215 231 258 265 DC, Temporal, Medium 235 253 288 297 FWR, Temporal, Medium 209 224 250 258 DC, Temporal, Low 232 251 282 292 1 FWR, Temporal, Low 207 221 248 256 DC, Non -temporal, High 255 270 303 309 FWR, Non -temporal, High 233 248 275 281 DC, Non -temporal, Medium 242 259 293 299 FWR, Non -temporal, Medium 219 232 262 267 DC, Non -temporal, Low 238 254 291 295 FWR, Non -temporal, Low 214 229 256 262 CS-2539 • 09/01/06 — Page 3 of 4 Ordering InCdrmation ❑ odel De❑Crl-ptCon ❑ odel DeEUrFptFon WALL HORN/STROBES CEILING HORN/STROBES PER 2-wire hornoltroCe, Ctandard Ed, redo PCCR 2-wire hornlIItroCe, Ctandard Cd, redo PER❑ 2-wire hornEltroCe, high Cd, redo PCCR❑ 2-wire hornMtroCe, high Cd, redo PER❑ 2-wire horn(EtroCe, Ctandard Ed, red, outdoor❑ PCCR❑ 2-wire hornEltroCe, Ctandard Cd, red, outdoorD PCR❑❑ 2-wire horn[EtroCe, high Ed, red, outdoorD PCERD❑ 2-wire hornCltroCe, high Cd, red, outdoorD PCW 2-wire horn[EtroCe, Ctandard Cd, white[] PCCW 2-wire hornlatroCe, Ctandard Ed, white❑ PCW❑ 2-wire horn[]ItroCe, high Ed, white❑ PCCW❑ 2-wire hornEltroCe, high Ed, white❑ PER 4-wire horn(UtroCe, Ctandard Cd, redo PCCR 4-wire hornEltroCe, Ctandard Ed, redo PCR❑ 4-wire homoltroCe, high Ed, redo PCCR❑ 4-wire hornOltroCe, high Cd, redo PCR❑ 4-wire horn[L[troCe, Ctandard Cd, red, outdoora PCCR❑ 4-wire homOltroCe, Ctandard Ed, red, outdoor❑ PERD❑ 4-wire hornEtroCe, high Ed, red, outdoor❑ PCEROD 4-wire hornmtrooe, high Cd, red, outdooro PCW 4-wire horn(EtroCe, Ctandard Cd, white❑ PCCW 4-wire hornaItroCe, Ctandard Cd, white❑ PCW❑ 4-wire hornoitrooe, high Cd, white❑ PCCW❑ 4-wire hornmtroCe, high Ed, white❑ WALL STROBES CEILING STROBES SR GtroCe, Ctandard Ed, redo SCR CtroCe, Ctandard Ed, redo SRO CtroCe, high Ed, redo SCR❑ CtroCe, high Cd, redo SRO CtroCe, Ctandard Cd, red, outdoor? SCR❑ CtroCe, Ctandard Ed, red, outdoor? SR❑O GtroCe, high Ed, red, outdoorD SCROD GtroCe, high Ed, red, outdoorD SW GtroCe, Ctandard Cd, white❑ SCW CtroCe, Ctandard Ed, white❑ SW❑ CtroCe, high Ed, white❑ SCW❑ CtroCe, high Cd, white❑ ACCESSORIES HORNS BBSUD DaCC>=o❑EElrt, wall, redo red❑ BBSW® EanOoocEirt, wall, white❑ toRtHorn, n, red, outdoorD BBSC® DaC❑=o❑ECirt, Ceiling, red❑ n, white❑ BBSCW® DaOODo❑=lrt, Ceiling, white❑ NOTE: "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. 6.8" dia. 7087diml ti- S1nCIC1r,Cult0 iOa trademarD, and OaDe0ellD, SpeRrDlertCl, and Sate❑ SenCorO are regiCtered trademarmoCHoneCwell Intemational InED 02006 DDHoneCwell International In=ll rightOreCerCedOOnauthoriCed uce oCthiOdoCument iOCtriEboprohiCftedO ❑❑M❑W❑LL-FCI 12 ClintonCille Road, North[ord, CT 06472 - ❑honeC1203E484-7161 - FO❑CI203C484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. 02006Gamewell-FCI. All rights reserved. ❑❑ El. Ca❑e❑elICID .E0E Cage 4 oC4 ❑ CC-2539 E09101106 194.' i ?6* A• s W.'3v11V C. Lynnu %A J, W& V*036 U.SA- ;4331771-11 Cr. Fax (423) T ! 1-4422 s_ Occupancy Name: Building Owner: Owner Agent: Date of Inspection: Testers Name: Certification Given" \/ RED YELLOW WHIT CONFIDENCE TEST ' REPAIRS / FIRE ALARM SYSTEMS (One System per Report) Senytic Conde Occupancy Address: 1130 5th Ave S, Edmonds ,:Cj1Vj1c A�5{SCiPCiOn ��t Aj>Flrtxn�trl C.h Phone Number.• 425-77 1-5541 JeTy rrcundliCli Phone Number: 425-771-554 i Wr433P-014 Inspection Type• Annual Ken Day Monitoring: N n FACP Manufacturer: FC1 # of initiating CircUite: 4 SFD Certification Number: Phone #: N/A Model #: "W0 A of Signal Circuits: '2 Quarterly SCI's- 062Z Account #: \'/A Location: $asvmcnt Elvctrival Notes: ALARM SYSTEM FUNCTIONALITY Yes No NIA All notification circuits operational? All circuits checked for electrical supervision? x All auxiliary equipment operates (elevators, fans, dampers)? X Key to panel avoidable? x Operating instructlene at panel? Trouble indicators function properly? Test record posted at panel? Signals received at central station? Operator *—yjc' _ Problems Found: Corrections Made: Date Corrected: Corrected By: SFD Certification # This certifies that this fire and life safety system has been roperly inspected for reliability to cover the Items Ilst In this and is canals with Seattle Fire Department Fire Code standards, and th dis repan-ci 8 are no and have been reported to the building Owner/Manager for r ct action. Signature of Tester: Phone Signature of Owner: SYSTEM DEVICES MODEL # TOTAL TESTED SATISFACTORY? Yes No NIA Horn/Strobes Mi,Tone ) Strobe Only Horn Only 1 ' Speaker/Strobes Speaker Only -)c Sounder Base Bens l SQe [[ v 6. 4! 6 :B Manual Pulls -Ki4j4r-10ti() ' T Photo Smoke Detectors -ba- a' Ion Smoke Detectors Combination SmokelHeat 135° Rate of Rise Heat 2000 Rate of Rise Heat 135' Fixed Temp Heat 2006 Fixed Tamp Heat Duct Smoke Detectors Detector Remote indicators x Remote Annunciators i Elevator Recall Output Fan Pressurization Door Holders Door Unlock Curtains/Roll-down Doors Fire Fighter Phones Main FACP Trouble with AC off? a No Batxenj backup operational? s No Battery voltage (no load) .2%,lvoltc Battery voltage (full load) volts Charge circuit voltage a2l-2 volts Battery Size Pane) Type.. Trouble w ith AC ofF7 No Battery backup operational? a No Battery voltage (no load) "7 volts Battery voltage (full load) VCRs Charge circuit voltage _� volts Battery Size Panel Type: Trouble with AC off? Yes No Battery backup operational? Yes No Battery voltage (no load) volts Battery voltage (full load) volts Charge circuit voltage volts Battery Size Panel T e: Trouble with AC off' Yes No Battery backup cperatlonai? Yes No Battery voltage (no load) volts Battery voltage (full load) volts Charge circuit voltage volts Battery Size FIRE PREVENTION JJJ d / Sel'1'lllg B7'lel; EC�IiIOliCI's, uilCli 12425 MeridianAve S INSPECTION REPORT:, SNOHOMISH CO. FIRE �• Mountlake Terrace � Everett, ' W9 98208 •, ❑ EDMOBRIER S • ❑BRIER DIST kirl FireDistrictL Phone (425) 551-1200 ❑ MOUNTLAKE TERRACE ❑ UNINCORPORATED i ����11� oig Fax (�?S) SSl -1 ?72 FREQUENCY STATION & SHIFT LOCATION: 11.30.5th Avenue S MD20 Annual 87-A BUSINESS NAME: SCaVUC CitndnS PHONE: SCHEDULED Nov 2013 DATE DUE r MAILING UFIR 427 ADDRESS: 1130 ,r�lh Awrjuc S, I«drn6r t, vVA W020 BUSINESS OWNER: b-hir»l, Jean � � HOME PHONE: � EMERGENCY-1: HOME PHONE: CURRENT KEY ACCESS-2: HOME PHONE: CITY YES NO % EMAIL: IV!A BUSINESS ❑ LICENSE PERSON CONTACTED: LA INITIAL INSPECTION DATE j NAME OF INSPECTOR:. FIDE SYSTEMS; Fit 1113 FE 6j f'2' =s i_.!� dux HAZARDS FOUND AND LOCATIONS / CO MUNI`CAyTION un 2 2 3 _.--_ _._... ..//// 3 4 4 5 6 5 6 7 7 I AGREE TO CORRECT THE ABOVE VIOLATION(S) IN THE NEXT 30 DAYS X 1st RE -INSPECTION DATE DUE: 2nd RE -INSPECTION DATE DUE: EXTENSION GRANTEDTO: FINAL RE -INSPECTION DATE DUE: VIOLATIONS CITED: PERSON CONTACTED: PERSON CONTACTED: INSPECTOR: PERSON CONTACTED: INSPECTOR: INSPECTOR: 2 DATE: DATE: DATE: 3 VIOLATIONS 1 5 VIOLATIONS 1 5 PRE -CITATION LETTER SENT CITATION ISSUED NUMBER: 4 2 6 2 6 DATE: CODE SECTION: 5 3 7 3 7 k RETURN RECEIPT RECEIVED 6 4 8 4 8 DATE: DISPOSITION: LETTER NEEDED ❑ YES ❑ NO LETTER NEEDED ❑ YES ❑ NO 8 FIRE DEPARTMENT COPY John J. Westfall From: Bjorback, Leif [Leif.Bjorback@edmondswa.gov] Sent: Tuesday, September 03, 2013 1:32 PM To: John J. Westfall Subject: RE: BLD2013-0603 Seavue Condominiums 1130 5th Ave S John, please review: Mr. Freundlich, We have received your request to remove (6) area separation doors within your condominium building at 1130 5th Ave. South. In response to your request, Fire Marshal John Westfall and I have performed considerable research that included review of original permit drawings and other archive documents, review of "as -built" drawings under the current building permit, a site visit, plus numerous conversations with Mr. Jay Grant, who is a resident of the building as well as the applicant for the current permit. It is evident that the fire -resistive construction that was designed into the original building is significantly lacking in its presence as well as effectiveness. The construction of the area separation walls appear to be building code deficient in several aspects: a. The associated doors are improperly positioned in the corridors and do not stack one above the other from floor level to floor level, as required by the building code. b. The door frames are labeled as 20-minute as opposed to the required 90-minute fire rating. c. Some of the doors are well out of alignment within their frames, presenting gaps between the door and frame. d. The walls themselves do not appear to be continuous within the concealed wall and ceiling framing. e. The lowest floor level does not contain of any fire doors across the corridor. By building code definition, area separation walls are to be continuous from the foundation to the roof, including roof parapets that do not exist. Your proposed plan to mitigate these deficiencies through the alterations under the current permit and the installation of a new fire alarm system throughout the building will significantly improve the level of safety of the building and its occupants. Comments regarding the alarm system from Fire Marshal Westfall are as follows: IFC 104.8 Modifications and IFC 104.9 Alternative materials and methods. The level of coverage required for this fire alarm system exceeds that, required by IFC 4603.6.6 for existing R-2 (multifamily) buildings. The level of coverage exceeds that required upon building design and acceptance. The level of coverage will substantially improve the performance and purpose over the existing fire alarm, providing location information to responding fire department resources. The level of coverage will instill confidence in the new system to provide early warning of fire incidents to the occupants. LEVEL OF COVERAGE FOR FIRE ALARM: Provide automatic and manual fire alarm system throughout the building. Install new addressable FACP and annunciators at East and North main entries. Provide new smoke detectors in corridors, common living areas, at FACP, and for door holders installed in accordance with IBC Chapter 7 and NFPA 80. Provide accessible notification in common areas. Provide and/or evaluate existing heat detection in garages and storage units. Addressing of devices is essential to improved coverage. Establish and maintain off -site monitoring for fire alarm system. In light of the apparent deficient nature of the current construction, and your desire to improve the overall safety of the building while operating on a limited budget, your request is hereby approved. From: John Westfall Sent: Monday, September 02, 2013 1:34 PM To: Bjorback, Leif Subject: BLD2013-0603 Seavue Condominiums 1130 5th Ave S Leif: The proposal/requirements below for the work being proposed will provide an improvement to the existing building and system. I recommend that we approve the work under the conditions that improve the building fire alarm system by level of coverage below. IFC 104.8 Modifications and IFC 104.9 Alternative materials and methods. The level of coverage required for this fire alarm system exceeds that required by IFC 4603.6.6 for existing R-2 buildings. The level of coverage exceeds that required upon building design and acceptance. The level of coverage will .substantially improve the performance and purpose over the existing fire alarm, providing location information to responding fire department resources. The level of coverage will instill confidence in the new system to provide early warning of fire incidents to the occupants. LEVEL OF COVERAGE FOR FIRE ALARM: Provide automatic and manual fire alarm system throughout the building. Install new addressable FACP and annunciators at East and North main entries. Provide new smoke detectors in corridors, common living areas, at FACP, and for door holders installed in accordance with IBC Chapter 7 and NFPA 80. Provide accessible notification in common areas. Provide and/or evaluate existing heat detection in garages and storage units. Addressing of devices is essential to improved coverage. Establish and maintain off -site monitoring for fire alarm system. John J. Westfall Fire Marshal Fire Prevention Services 425-771-0213 Desk 425-775-7721 Fax 425-231-3644 Mobile �+ro�wac,�ti co IRE D 1N is-?M T John J. Westfall From: John J. Westfall Sent: Monday, September 02, 2013 1:34 PM To: 'Bjorback, Leif Subject: BLD2013-0603 Seavue Condominiums 1130 5th Ave S Leif: The proposal/requirements below for the work being proposed will provide an improvement to the existing building and system. I recommend that we approve the work under the conditions that improve the building fire alarm system by level of coverage below. IFC 104.8 Modifications and IFC 104.9 Alternative materials and methods. The level of coverage required for this fire alarm system exceeds that required by IFC 4603.6.6 for existing R-2 buildings. The level of coverage exceeds that required upon building design and acceptance. The level of coverage will substantially improve the performance and purpose over the existing fire alarm, providing location information to responding fire department resources. The level of coverage will instill confidence in the new system to provide early warning of fire incidents to the occupants. LEVEL OF COVERAGE FOR FIRE ALARM: Provide automatic and manual fire alarm system throughout the building. Install new addressable FACP and annunciators at East and North main entries. Provide new smoke detectors in corridors, common living areas, at FACP, and for door holders installed in accordance with IBC Chapter 7 and NFPA 80. Provide accessible notification in common areas. Provide and/or evaluate existing heat detection in garages and storage units. Addressing of devices is essential to improved coverage. Establish and maintain off -site monitoring for fire alarm system. 7ohn 3. Westfall Fire Marshal Fire Prevention Services 425-771-0213 Desk 425-775-7721 Fax 425-231-3644 Mobile SxanonNSU ca i! f John J. Westfall From: John J. Westfall Sent: Monday, September 02, 2013 1:29 PM To: 'Bjorback, Leif Cc: Kevin Zweber Subject: BLD2013-0603 Seavue Condominiums 1130 5th Ave S Leif: Regarding current compliance status of Seavue Condos: BACKGROUND FROM FD FILE: 18 unit, type V-1hr multi -residential dwelling constructed in 1979. Designed in 3 multiple -story "towers" within allowable area (7900 s.f. each tower) for 1976 UBC and provided with area separation walls (ASW). Approvals for driveway slope from Edmonds Fire Chief 2/29/1980. The design provides interior corridors serving units and two stair enclosures providing egress. Memoranda on file indicate a problem with certificate of occupancy due to insufficient evidence of proper construction of ASWs. Fire sprinklers were required, however, Board of Appeals (BA) determination was made on that decision. Limited documentation can be found in Building for the BA determination, except that for 1979 UBC, the allowable area was recalculated to where only a single ASW was then required. No fire sprinklers were required. Automatic fire (& smoke) alarm system installed providing detection to interior corridors at each level and common areas plus notification throughout dwellings. By March 171982, City of Edmonds passed ordinance requiring new and existing upgrades to "automatic, manual" fire alarm systems. The enforcement effort also called to evaluation other life safety features of the existing buildings, including emergency lighting, dwelling smoke alarms and verification and testing of all dwelling entry assemblies (corridors). This effort appears to have included improvements made to a (limited) manual and automatic detection system to a automatic system throughout corridors for this building. Records show all improvements had been completed by 11/24/1982. An Ademco Model #868 fire alarm control panel (FRCP) was initially installed at construction. In March 1988, problems with existing FACP caused replacement of FACP panel board, with Fire Department acceptance. The years following indicate that multiple water leakage issued may have degraded some initiating devices installed, particularly a heat detector over FACP in 1995. Various initiating devices were replaced for this and other reasons. Inspectors found FACP "trouble" on routine inspection in November 1996. By 1997, a new FACP Firelite MS-44126. Service report in January 1997 indicates 25 horns, 13 smoke, 14 heat detectors and 4 pull stations on system. Since 1997 to date, alarm system has required minimal service replacement problems to initiating devices and batteries. The most recent report on file performed 3/26/12. On -site inspection by myself and Building Official (BO) Bjorback identifies aged devices and installation shortfalls in coverage by current standards. FROM BUILDING FILES: TCO 6/27/1980. Building repairs due to automobile crash against building, prompted Building Department to pursue final certificate. Notes of improperly constructed ASW. Apparent completed repairs due to CO 10/31/1985 FROM ORIGINAL PLANS: Manual fire alarm was required (review corrections added) with rate of rise heat detectors in parking garages and storage rooms per 1976 UFC. The upgrade to full automatic coverage in corridors may have been part of BA decision or a community life safety initiative implemented by EFD in 1982. CURRENT: Building plans accepted under 2009 IBC. Maintenance issues and concerns plus ventilation and accessibility improvements have come to owner consideration for improvement to City. ASW installation shows deficiencies in the corridor doors where incomplete separation are been identified. For accessibility and ventilation concerns, as well as an aging tenant population, two mid -interior corridor doorways are proposed to be removed. 2009 IBC allows the additional allowable area by removal of corridor doors, however, fire sprinkler installation is assumed as a protective overlay upon this increase. 20 minute smoke- and draft -assemblies to stairways are being upgraded to 90 minute FR assemblies, as originally required, but not installed, and tested to close and latch completely. Settling has occurred over the 34 year old structure. Additionally, stairway doors from interior corridors are proposed on hold -opens by new fire alarm system (IBC Chapter 7 and NFPA 80). Future plans will replace elevator that will also require fire alarm interface. The HOA/applicant has been forthcoming with the issues and is motivated by building safety and interested in correcting the building deficiencies while improving some problem functional issues there. DISCUSSION: Building was accepted by City in 1985 and CO issued. The population of Homeowner's Association is aging and few, if any, original owners remain. The effectiveness of the ASW as constructed/accepted, and as eroded by age and settling over 34 years, has come into question by BO. For instance, corridor doors at the ASWs do not align and there are no parapets. Shortfalls in the fire alarm system to existing standards are proposed to be upgraded, that could allow tie in to future upgrade efforts like elevator. New technology addressable FACP and upgraded components would assure that early warning and detection can improve the occupant notification, and improve the effective fire department response to this building. Complete coverage throughout the living and storage spaces will improve the automatic system and provide confidence that impairments to coverage meets standards. Owners are of fixed income and this discussion includes consideration that HOA could do nothing to improve any of their building life safety features, including those the City may have accepted under original CO. IFC 104.8 Modifications and IFC 104.9 Alternative materials and methods. The level of coverage required for this fire alarm system exceeds that required by IFC 4603.6.6 for existing R-2 buildings. The level of coverage exceeds that required upon building design and acceptance. The level of coverage will substantially improve the performance and purpose over the existing fire alarm, providing location information to responding fire department resources. The level of coverage will instill confidence in the new system to provide early warning of fire incidents to the occupants. LEVEL OF COVERAGE FOR FIRE ALARM: Provide automatic and manual fire alarm system throughout the building. Install new addressable FACP and annunciators at West and North main entries. Provide new smoke detectors in corridors, common living areas, at FACP, and for door holders installed in accordance with IBC Chapter 7 and NFPA 80. Provide accessible notification in common areas. Provide and/or evaluate existing heat detection in garages and storage units. Addressing of devices is essential to improved coverage. Establish and maintain off -site monitoring for fire alarm system. John J. Westfall Fire Marshal Fire Prevention Services 425-771-0213 Desk 425-775-7721 Fax 425-231-3644 Mobile _` , Iwonow-911 co DI�TRICT #13"ECEIVED Seavue Condominium Seavue. Association of Apartment Owners A Washington State Non-profit Organization 1130 5t' Avenue South #B1 Edmonds, WA 98020 August 21, 2013 Leif Bjorback City of Edmonds Building Official Development Services Department 121 5"' Avenue N. Edmonds, WA 98020 Re; Fire Door Revision Request Permit # 20130603 r 12013 +)EVEI.ORi19ENT SERVICE COUNTER The Seavue Condominium requested a revision. of the approved plans that itcludes the removal of two separation fire doors on the three residential floors within the envelope. This request was made based on a number of factors of which we would like to articulate. We consider the safety of our residents and guests to be paramount in our overall objective. We are trying to resolve issues based on the current condition of a 1979 building by mitigating the fire prevention risk in the most appropriate manner though it may not fall within standard compliance of IBC 2009 edition requirements. 'However requirements can be meet though objectives based on consideration of IBC 2009 edition, Section 104.11 as an alternative construction method and should amply satisfy and comply with the intent of the provisions of the code. We found the building to be lacking in many areas that seemed compliant in fire safety. Specifically some of the issues include: the two internal hallway separation doors on each residential floor vary in placement and do not stack upon one another in order to offer a compliant stack barrier. In addition the fire separation doors are required to be in alignment with the unit's fire separation barrier, which they are not. There is no provision to mitigate this in the entire corridor area with the exception of the furthest west end where some additional separation was added. The revised drawing shows the actual separation door placement, which cannot be clearly .seen by observation. Measurement of the doors clearly shows the imperfection as indicated on the residential floors. We have offered supporting data as provided in Section 104.11.1 relating to our research inspection. Not only are the separation doors placed improperly, we found there was no type of fire block where the fire doors where built. Supporting evidence of this are pictured in the attached Exhibit "A" offering a view of one of the doors on the third residential floor. This shows how far off some of the doors are from the where the fire door should have been located. In addition inspection of all the .fire doors throughout the envelope, which includes those at the stairwells in addition to the internal separation doors, do have compliant 90 minute rated doors, but all the jams are 20 minute fire rated negating the barrier itself. Because of these deficiencies, as outlined, we have alternatively offered solutions that mitigate the risks and provides for a higher safety solution and remedies fire prevention offering real protection. The solutions are provided in the revision plans as identified on permit revision #3 dated July 26, 2013. On page A-1.1, we call for installation of a replacement fire alarm system. This would replace the existing fire alarm control panel (FACP) with a state of the art analog addressable FACP and new power supply. The installation includes new detection devices in common areas to provide complete automatic and manual detection; replaces existing bells in common areas with ADA compliant synchronized horn strobes; provides magnetic door holders, which were previously approved in the current permit, on corridor / stairwell doors with specifications as outlined on page A-2.1 of the revision, and prewires the elevator machine room for planned future elevator panel upgrade. The system will also allow for offsite monitoring with a U.L. Listed monitoring device that is not currently in place. All exit signs will be replaced and new LED emergency lighting are to be installed. Each of the two stairwells on each of the residential floors and the one basement entry which provide for the envelope will have new 90-minute medal fire rated frames and doors installed. At the front east entrances we are relocating the current fire door from its current position 1' west to avoid conflict with the fire extinguisher cabinet and to allow for the opening of the door not to interfere with the flow path of the staircase. This is detailed in the architectural drawings on page A-2.2, A-2.3, and A-2.4. Please let me know if you have any questions. Respectfully submitted, Jerry Freundlich, President Jerome Freundlich 1130 5t' Ave. S #304 Edmonds, WA 98020 E: president@seav'ue.org T: 425.771.5541 ,��� x•'a C q '� f .. .f S� u . �:: T .7 S 3jb � x6 =.� t �„ � ��t .fir tE �c� �F P r�, y'�f rGt � r � S ,� ;.,j f'�ti jl i^f �. r -rlP � � �' "� �i �aYoh.�ir;�lrl 6' � 1,.�'1 � . ]Eti Y ) .�. � . `t �^ - • � +� �''r s.. ,. 1 _ „y Yk %:� l� � .., �� - - .. , ;�: _ „J,; u ,;.� . i4 � 14 frt .. e.; •- 4 � fl� -, � � _ � � f 7 { rr� �x�� ' : 1i h ��', 3 �'T � » CITY OF E®MONDS HARVE H. HARRISON MAYOR CIVIC CENTER • EDMONDS. WASHINGTON 98020 (206) 775-2525 COMMUNITY DEVELOPMENT DEPARTMENT June 4, 1982 Mr. Bob Brokaw 501. Colby Everett, WA 98201 18 UNIT CONDOMINIUM @ 1130 5TH AVENUE S. PERMIT #780360 Per your request, I have recalculated the basic allowable area for the apartment building at the above address. The 1979 edition of the Uniform Building Code increased the basic, allowable area for this type of building to a maximum of 20,400 square feet in this case. However, the actual area for this building is approximately 29,000 square feet.. Therefore, one area separation wall would still be required by the 1979 Uniform Building Code. In answer to your question, there is no substitution of fire alarms permitted by the Uniform Building Code for the area separation. Please contact the Building Division within 10 days regarding your intentions. -" AO-NAe Harold Reeves Building Official HR/cn i QQ G, APR 2 0 1982 s f �s �-c, �n � T h•�C d cc •r . �o�' �. tJ,'pG, 4 i i4-s .Z oti. � !. � � : Yr �•-f cam.,. ,�,rs,, �� �/0 4 .� 44 (2 We `OtY'c ocJ�Ilrz /iv . Rio Ie4i/ /o c � tells ,- c 401;lrrel /*.r "17 5��� 5 o s�6� Ally s ��•�� �-r� p _ ��s�,�;��� do .27, ��-re 4cc'/ �' � c ��► lor.r-xe C4-VA f see-`` r' �9 le,/e y�a seG ►' weo., :� 711'e-el" e CC f� CITYOF E®f1 ONDS HARVE H. HARRISON 1� MAYOR CIVIC CENTER • EDMONDS. WASHINGTON 98020 (206) 775-2525 COMMUNITY DEVELOPMENT DEPARTMENT November 25, 1981 Mr. Bob Brokaw 501 Colby Everett, WA 98201 18 UNIT CONDOMINIUM @ 1130 5TH AVENUE S, PERMIT #780360 As a result of a site inspection on Monday, November 9, 1981, it had been determined that the two-hour area separation walls, as required by UBC Chapter 5, are: not in place. This is a life safety hazard and must be corrected as soon as possible. After a discussion with a representative from ICBO it was determined that the option of sprinkling along both sides of the fire wall locations would serve as comparable protection. However, this or any other resolution of the problem must be acceptable to the City's Board of Appeals. Enclosed is an application for the Board of Appeals. Please complete and return to the Building Division within 10 days. If there are any questions or you desire assistance in filling out the application, please contact this office. Harold Reeves Reeves Building Official HR/cn enclosure cc: City Attorney Fri r,�eMaLr�s!ha�l CITY OF EDMONDS CIVIC CENTER • EDMONDS. WASHINGTON 98020 (206) 775-2525 COMMUNITY DEVELOPMENT DEPARTMENT October 23, 1981 Seavue Condominium Homeowner's Association c/o Mr. Bob Vrooman, Jr. 1130 5th Avenue S. Edmonds, WA 98020 � 4l -o t ,:i� --�-1 HARVE H. HARRISON YOR RECEIVED 3CT •2 61981 EDMONDS FIRE DEPL 18 UNIT CONDOMINIUM @ 1130 5TH AVENUE S.; PERMIT #780360 The Building Division is unable to find evidence that the two-hour area separation walls are installed as required by UBC Chapter 5 at, the above address. Our records indicate that the required wallboard inspection was not called for prior to taping and finishing of the walls. The absence_ of the area separation walls would constitute a life safety hazard. The walls must be in place and inspected prior to issuance of a Certificate of Occupancy for the building. Also these building code items must be completed prior to final approval: 1. Provide positive drainage in crawl space -- no standing water permitted. 2. Remove all form material and wood scraps from crawl space. 3. Provide nuts for anchor bolts in -crawl space area. 4. Catch Basin in west driveway vicinity (4th Avenue S.) to have intake pipe chipped back and catch basin grouted. Use or occupancy of the building without issuance of a Certificate of Occupancy from this office is a violation of UBC 307. Please contact the Building Division within 10 days regarding your intentions in this. matter. Harold Reeves Building Official HR/cn cc: Edmonds City Attorney Edmonds Fire Marshal certified- TO- r'_)M&1r�riV-� Fri Community Devei. CIT" OF EDMONDS 250 - 5th North EDMONDS, WASHINGTON 98020 DEPARTMENT: �= 1, arm- ��` MY �4 i�y� r.+.Sv�• N 40P.+t�t 444 :4 4K ,I,;'�mwrvnx>• k � r�n4V ( 4 �4lY.K'• ��t 4�.V1 ifM4'. Y.x�Vh':45V.4xlVhY XVix45iylf.5ty }�Whi(A lV X�XNf(.4'HI.YMV.•XXNttftXXtX.lYth'INlh'Jl�`II(tl(ftl Certification Given RED YELLOW I WHITE CONFIDENCE TEST J REPAIRS FIRE ALARM SYSTEMS (One System per Report) 0cj�TrF=> Occupancy Name: Scavuc Condo Occupancy Address: 1130 58i Ave S, Edmonds , Building Owner: scavuc [tondo Phone Number: 425-771-5541 Owner Agent: Jeny Freun►iii& Phone Number: 425-771-5541 Date of inspection: 03/2Q7012 Inspection Type: %/ Annual Quarterly Testers Name: Kon Day SFD Certification Number: SCP- D-06223 Monitoring: N/A Phone #: N/A Account #: N/A FACP Manufacturer: Firc tiw Model #: MS-44128 Location: Bassi wA Bl"Ariud # of Initiating Circuits: 4 # of Signal Circuits: 2 Notes: ALARM SYSTEM FUNCTIONALITY yes No NIA All notification circuits operational? X All circuits chocked for electrical supervision? All auxiliary equipment operates (elevators, fans, dampers)? x Key to panel avalla610 Operating Instructions at panel? X Troupe indicators function properly? Test record posted at panel? Signals received at central station? Operator # Problems Found: Corrections Made: Corrected By: A Date Corrected: 2 / Z SFD Certification This certifies that this fire and life safety system has been properly inspected for reliability to cover the items listed in this report and is consistent with Seattle Fire Department Fire Code standards, and that discrepancies are noted and have been reported to the building Owner/Manager for corrective action,_--, Signature of Tester: Phone #: a,0 r0 35-6 Y40 Signature of Owner. w SYSTEM DEVICES MODEL # TOTAL TESTED SATISFACTORY? Yes No N/A Ham/Strobes Mirtunc 17 t Strobe Only Ham Only Speaker/Strobes Speaker Only Sounder Base Bells Ademcn [lVn-&12 fs Manual Pulls Ki"e MS6 5 5� Photo Stnake Detectors System Sen%nr 21 W 13 Ion Smoke Detectors Combination SmokeMeat 135" Rate of Rise Heat Ki&ul; S-15-C 15 ' 20V Rate of Rise Heat 135' Fixed Temp Heat 2000 Fixed Temp Heat Duct Smoke Detectors Detector Remote Indicators Remote Annunciators I Elevator Recall Output Fan Pressurization Door Holders Door Unlock Curtains/Roll-down Doors Fire Fighter Phones IV Main FACP Trouble with AC off? Y No Battery backup operational? No Battery voltage (no load) 11.7 volts Battery voltage (full load) 13?- volts Charge circuit voltage s volts Battery Size -7A",, Panel Type: d Trouble with AC off? Yes No Battaq backup aparatlona17 Yes No Battery voltage (no load) Vohs Battery voltage (full load) volts Charge circuit voltage Vohs Battery Size Panel Type: Trouble with AC off? Yes No Battery backup operational? Yes No Battery voltage (no load) voles Battery voltage (full load) volts Charge circuit voltage Vohs Battery Size Panel T Trouble with AC off? Yes No Battery backup operational? Yes No Battery voltage (no load) volts Battery voltage (hull load) volts Charge circuit voltage volts Battery Size i.�i�77S>SS;,u Fre:"*�23)•77Sw•c::2 Occupant yName: Building Owner: Owner Agent: Date of Inspection: Testers Name: Monitoring: N'.A s:avut Condo Certification Given INED WHITE I CONFIDENCE `BEST >/ REPAIRS FIRE ALARM SYSTEMS (One System per Report) Occupancy Address: 1130 sth Ave s: Edrraah .s Phone Number 42'i-7`1-3i1 hriy r cuntjhch Phone Number: 42f-7?1-5541 g ay};??rll3 Inspection Type: V Annual Quarterly Fun Day SFO Certification Number: Cp-�°2- FACP Manufacturer. Fire rue # of Initiating Circuits: # Phone #: 11A Account #: N/A Model #: MS-4412R Location: Bsswi-Mr EIccrricril # oaf Signal Circuits: Notes: �_-- ALARM SYSTEM FUNCTIONALITY Yes No NIA All notification Circuits operational? 1 All circuits checked for electrical supervision? All auxiliary equipment operates (elevators, fans, ttarrrpers)? 1/ � Koyto panel availably? 9pe-ta.tit10 instYLACtions at panal? -- � rTr—fluhla indicators funetror-t propvrly'3 t V Test rec#td posted at panel? Signals raceivad at central station? Operator # Problems Father: ��tjt Corrected By: Corrections !Made: Date Corrected: SFD Certification t �Vo0Q This certifies that this fire and life safety system has been properly inspected for reliability to cover the items listed in this report and is consistent with Seattle Fire Department Fire Code standards, and that discrepancies are noted and have been reported to the building Owner/Manager for corr$ctive Signature of `ester:, Signature of 0-wher: Phone #: ,Ag4 4�p� SYSTEMDEVICES MODEL # TOTAL TESTES ,SATISFACTORY? � Yes No NIA HarnlStraba: _ Strobo Only l��itil+ii_ �? 1-7 Horn Only SpeakerlWabes Speaker Only Sounder Base Bells 1'F1?-6-12 ManualPullls Kiddie NIS5 Photo Smoke DcUr i E _1r.1— �� hLctyl lcrnwf 21 (10 11 Im Smoke Detectors Combinatlon SmoketHeat 135" Rate of Rise Heat Kiddic S-1 i-c 15 20W Rate of Prise Heat ✓ 135' Fixed Temp Heat 20T Fred Tamp Heat Duct Smoke Detectors f Detector Remove Indicators Remote Annunciators Elevator Recall Output Fan pressurization 1/ Door Holders f Door Unlock OurtainalRoll-down Doors Firc Flghtcy Phones _� ✓� Main FRCP Trouble with AC off? Y s No Y No Battery backup operational? Battery voltage (no load) volts 8attory voltaga (full load) volts Charge e1PCUlt voltage volts Battery Size nM 7�_d Pane! Type: Trouble with AC off? Yes No Battery backup operational? Yes No Battery voltage !no load) volts Battery voltage {foil load) volts Charge circuit voltage volts Battery Size Pane Type: Trouble with AC off? Yes No Battery backup operational? Yes No Battery voltage (no load) volts Battery voltage {full load) volts Charge Circuit voltage volts Battery Siz® Paned Type: Trouble with AC off? Yes No Battery backup operational? Yes No Battery voltage (no load) volts Battery voltage (full Ioad) volts Charge circuit voltage volts Battery Size MAIN 19023 3e Ave W, Suite E, Lylmwocd, WA 98036 U.S-A. (42S) 771.116d Fxc (425) 771-4422 3SAikt;;:d: a;ei..... Occupancy Name: Building Owner: Owner Agent: Certification Given RED YELLOW I WHITE CONFIDENCE TEST I ✓ FIRE ALARM SYSTEMS (One System per Report) REPAIRS Sutvuc Condo Occupancy Address: 113o 5t11 Ave s. Edmonds SLavue Condo Phone Number: 425-771-5541 Jerry Freuniilich Phone Number: 425-771-5541 Date of Inspection: WNW ! Inspection Type: %/ Annual Quarterly Testers Name: %nny Ifincs SFD Certification Number: SCP. N -o"l(a Monitoring: A% Phone #: N�A- Account M N(IP, FACP Manufacturer: Firc Lite Model #: W-441211 Location:6,se-,.-,1, tL� # of Initiating Circuits: 4 # of Signal Circuits: 2 Notes: ALARM SYSTEM FUNCTIONALITY Yes No NIA All notification circuits operational? All circuits checked for electrical supervision? All auxiliary equipment operates (elevators, fans, dampers)? Key to panel available? V'*' Operating instructions at panel? V Trouble indicators function properly? V'- Test record posted at panel? Signals received at central station? Operator # �L Problems Found: No«ass 303, too, too Corrections Made: Date Corrected: Corrected By: SFD Certification M This certifies that this fire and life safety system has been properly Inspected for reliability to cover the items listed in this report and is consistent with Seattle Fire Department Fire Code standards, and that discrepancies are noted and have been reported to the building Owner/Manager for dive 501on. Signature of Tester: Phone #: 2d6 '3sG -`�` °S Signature of Owner: SYSTEM DEVICES MODEL # TOTAL TESTED SATISFACTORY? Yes No NIA HomlStrobes Mirtonc 17 Strobe Only Ham Only Speaker/Strobes Speaker Only Sounder Base Bells Ademco (Wri-& 12 ti 6 Manual Pulls Kiddie MS6 5 S Photo Smoke Detectors Syxtcm Seer 21 W 13 Ion Smoke Detectors Combination SmokeMeat 135• Rate of Rise Heat KiWt; S-iS-C 15 20V Rate of Rise Heat 1350 Fixed Temp Heat 20V Fixed Temp Heat Duct Smoke Detectors Detector Remote Indicators Remote Annunciators I Elevator Recall Output Fan Pressurization Door Holders Door Unlock Curtains/RolWown Doors Fire Fighter Phones Main FACP Trouble with AC off? No Battery backup operational? Yps No Battery voltage (no load) i3.W volts Battery voltage (full load) I1• ('0 votes Charge circuit voltage , ! volts Battery Size n-1/ 11 A Panel Type: Trouble with AC off? Yes No Battery backup operational? Yes No Battery voltage (no load) volts Battery voltage (full load) volts Charge circuit voltage Vohs Battery Size Panel Type: Trouble with AC off? Yet No Battery backup operational? Yes No Battery voltage (no load) volts Battery voltage (full load) volts Charge circuit voltage volts Battery Size PanelType: Trouble with AC off? Yes No Battery backup operational? Yes No Battery voltage (no load) volts Battery voltage (full load) volts Charge circuit voltage volts Battery Size :............. A. V JJ`:t ".;I •Y• a J L"ti•N':l rLLii•. V:i • X Certification Given RED YELLOW WHITE CONFIDENCE TEST I J 19023 360'Aoe W, Suite E, Lyttavood, WA 99036 U.S.A. L REPAIRS J (42.S)771.1166 Fax(425)771-4422 jyy�)L.+:: A LKL v?_ a FIRE ALARM SYSTEMS (One System per Report) Occupancy Name: Scavuu Condo Occupancy Address, IM 501 Ave S, Edmo►Ws � Building Owner: 5#-avac Condo Owner Agent: Jean Lehlon Date of Inspection: 03r1612010 Testers Name: �� ej t,- ' VV . s Monitoring: �//.k FACP Manufacturer Firc 1i1i # of Initiating Circuits: 4 Phone Number: (425) 778-9M9 Phone Number: (425) 778-9899 Inspection Type: / Annual Quarterly SFD Certification Number: SCP-N-o1lci Phone #: KJ•% Model #: MS-44 t 2B # of Signal Circuits:? Account #: !u/A Location: Uso ka-., - Notes• ALARM SYSTEM FUNCTIONALITY Yes No N/A All notification circuits operational? All circuits chocked for electrical supervision? All auxiliary equipment operates (elevators, fans, dampers)? Key to panel available? V/ Operating instructions at panel? Trouble indicators function properly? Test record posted at panel? Signals received at central station? Operator 1 Problems Found: WC, v. Corrected By: Corrections Made: Date Corrected: SFD Certification #: This certifies that this fire and life safety system has been properly inspected for reliability I to cover the items listed in this report and is consistent with Seattle Fire Department Fire Code standards, and that discrep cies are noted and have been reported to the building Owner/Manager for rmuective - Signature of Tester:L/Phone #: Lot- --3 �;6-K6D5 Signature of Owne SYSTEM DEVICES MODEL # TOTAL TESTED SATISFACTORY? Yes No N/A Horn/Strobes Strobe Only Horn Only NXc- Speaker/Strobes Speaker only Sounder Base Bells Adetnen (JFn-&12 6 Manual Pulls Kiddie M56 5 a Photo Smoke Detectors System Sen or 21(H) 13 CIS Ion Smoke Detectors Combination SmokeMeat 1350 Rate of Rise Heat KU14; 5-15-C 15 2000 Rate of Rise Heat 135° Fixed Temp Heat 20V Fixed Temp Heat Duct Smoke Detectors Detector Remote Indicators Remote Annunciators . e> C> ✓ Elevator Recall Output Fan Pressurization Door Holders Door Unlock Curtains/Roll-down Doors Fire Fighter Phones Main FACP Trouble with AC off? No Battery backup operational? kaja No Battery voltage (no load) Is • 8 volts Battery voltage (full load) i 3, volts Charge circuit voltage Q—I volts Battery Size (2v 7.%i% Panel Type: Trouble with AC off? Yes No Battery backup operational? Yes No Battery voltage (no load) volts Battery voltage (full load) volts Charge circuit voltage volts Battery Size PanelType: Trouble with AC off? Yes No Battery backup operational? Yes No Battery voltage (no load) volts Battery voltage (full load) volts Charge circuit voltage volts Battery Size PanelType: Trouble with AC off? Yes No Battery backup operational? Yes No Battery voltage (no load) volts Battery voltage (full load) volts Charge circuit voltage volts Battery Size REPORTED BY_ 1-8e4KA0AJ& r Y7S OF SUBJECT ADDRESS: CONCERNS/ / HAZARDS: L oc4-c6o X 67 - 3 FOLLOW-UP: SIGNED 0 zJ PA4-wc,((- X61 . wrh C44 jkvv,01�5 9&0-F A-rc, E—SS &9 56CL-"-� I 6&,�r SIGNED City of Edmonds * Office of Fire Prevention CITY OF EDMONDS CIVIC CENTER • EDMONDS, WA 98020 • (206) 771-0215 . FAX (206) 771-0208 FIRE DEPARTMENT 890_19y Pj LC � I Mr. John Lettengarver Seavue Condominiums 1130 5th Ave S. #303 Edmonds, WA 98020 Dear Mr. Lettengarver: June 30, 1995 LAURA M. HALL MAYOR The Fire Department has received a copy of your annual fire alarm test from Northwest Communications & Alarm. There was a problem discovered in the heat detector in the fire alarm panel room. Apparently water had managed to enter the detection device and damage it. Although the detector was replaced, a water leakage problem could damage the new device. A situation involving excessive heat or fire in this area could spread before being discovered, if the heat detector was faulty. Please investigate the situation to assure that no further water problems will cause another heat detector failure. Call me at #771-0215 if I may be of service. Thank you for your assistance in keeping Edmonds safe! Sincerely, John J. Westfall . Senior Inspector • Incorporated August 11, 1890 • Sister Cities International — Hekinan, Japan Northwest Communications & Alarm, Inc. 21DO -196th St. S.W. • Suite 1131114, Bldg. D P.O. Box 6277 Lynnwood, Washington 98036 800 962-2220 • 206 775A456 9 206 623-4362 FIRE ALARM INSPECTION (PAGE 1) // FAX 206 7764897 DATE: 6 AMS ACCT: N BLDG NAME: S FA Vy c A'pTS _OCCUPIED AS: ADDRESS: / CN S'ry"A... S CITY: C DM(3W >S ZIP: 9 u 022 BILLING ADDRESS: CITY: ZIP: INSPECTED BY: _L_�/e- _ TITLE: TYPE OF TEST: MONTHLY [ ] QUARTERLY [ ] SEMI-ANNUAL [ ] ANNUAL [yj FIRE DEPT. OFFICIAL CONTACTED: &iIk- - CONTROL PANEL MANUFACTURER ' E ►^> U MODEL NO. 'R 6 ?i NO. OF INITIATING CURCUITS: �I NO. OF SIGNAL CIRCUITS 2- BATTERY VOLTAGE VOLTS CHARGE CIRCUIT 10`2 (e VOLTS BATTERY VOLTAGE UNDER FULL LOAD) 3,Z � VOLTS (SIGNALS OPERATING) TROUBLE SIGNAL WITH AC POWER OFF: ALL SIGNALS OPERATE ON AC POWER: YES t, NO N/A YES t,-' NO ALL SIGNALS OPERATE ON STAND—BY POWER: YES L--� NO N/A ALL CIRCUITS CHECKED FOR ELECTRICAL SUPERVISION: YES L. NO N/A CONTROL PANEL CHECKS MADE PER MANUFACTURERS' INSTRUCTIONS: YES NO N/A ALL AUXILLARY EQUIPMENT OPERATES: (ELEVATORS, FANS, DAMPERS) YES NO N/A CENTRAL STATION OR REMOTE CONNECTION: YES NO N/A AUTOMATIC TIME DELAY OF GENERAL ALARM MINUTES. NONE INSTALLED KEY TO PANEL AVAILABLE? YES NO OPERATING INSTRUCTIONS AT PANEL? YES ' ✓/ NO TEST RECORD POSTED AT PANEL? YES NO N/A Northwest Communications & Alarm, Inc. FIRE ALARM INSPECTION (PAGE 2) 2100.196th St. S.W. • Suite 1131114, Bldg- L) P.O. Box 6277 Lynnwood, Washington 98036 800 962-2220 • 206 77&4456 • 206 623-4362 FAX 206 776-4897 RLDG NAME: Sc'A � 11�. -'TS ADDRESS: 1"30 -5 AVc S" FDr'owr>S THIS IS TO CERTIFY THAT THIS FOR RELIABILITY TO COVER THE WITH FIRE ALARM MAINTENANCE A. SIGNATURE OF OWN OR REPRESENATIVE, B. SIGNATURE OF FIREV ALARM REPRESENTATIVE C. NAME OF TESTING FIRM D. MAILING ADDRESS E. PHONE NUMBER: F. WA CONTRACTOR LIC. #: PROBLEMS FOUND: f2i- per' FIRE ALARM SYSTEM HA5 i zza rnvKjvaL% & +..•,_ ----- ITEMS LISTED I�HCORECTIONS HAVECONSISTENT MADE. STANDARDS, AND DATE STATE LICENSE # LOVOk-1.110 99 NORTHWEST COMMUNICATIONS ALARM, INC. P.O. BOX 6277 LYNNWOOD, WA 98036 (206) 775-4456 1 CORRECTIONS NWCOMAI11ODL A to KM 4 ^- 67k) Qo6V iDo Sty.- -- --- - - ---- ---- _ _ ./ . _L'o N_ 1, � �?'S A� /3 _V S S -�•J C� S_ _ in/_ _ �� �,�, �- o-- - - y�'� -�& - ,) S / v &. _ - S7-0aA4'E svGiagsi-;!�-b -r#jr- sNE col- ,7w cT - - TNT T_ - —E -- epn� iJ ��rz ,S -- -✓`� T =�NTjv !i�'�- - - WASHINGTON BURGLAR ALARM & SIGNAL CO. (Washington Equipment Co., Inc.) 2400 - 4th Avenue Seattle, Washington 98121 206-622-6041 December 28, 1982 SNOCOM P.O. Box 2243 Lynnwood, Wa. •iM DECEIVED JAN , 1982 IEDMONDS FIRE DEPT. 61� C� Gentlemen: Please be advised that the following Fire alarm syptem will no longer be maintained by our company. L 51 atn Seaview Apartments m 9 Wes o Effective 12-28-82 Thank -You Gail M. Beckwith RECEIVED DEC 3 0 1982 UL Listed and FM Approved Central Station 4 Apartment Name 3 1 IS # of Stories of Units per Bldg. ALARMS Yes No Re uired? ✓ Installed? Audible throughout? EMERGENCY LIGHTING Required? ✓ Installed? SMOICE DETECTORS Installed? r/ A _ 17 Address U.F.I.R. # SELF -CLOSING DOORS Yes No Required? ✓ Installed? EXIT SIGNS Required? ✓ Installed? HALLWAY LIGHTING Required? / v Installed? �ssOG l�'e4 : gp�p �i'oow►a.:� UVo��i� (0 2`{ — `l �70 �-- me, '00a d I q - � /l�Ge, r. .cay� ,, t,c,c L . — Rex— 0, r �� 2.y $2, 2� � 1 r3,•6 vR,opai.Qk,,4 -1~ho4 dodws 41.4. ►ibJ6 Stir etostuct#,),-1-r►0+ -I-hg rl�c�s.r. sys��w• w ��� �� P�,e o�� ;Ns�-Q.,��-��u ��1. -1-h o J• OckNQAC-4 V is brag/ sC51jewA LOL -�6 tYlbSk . Ro f_cl le _ • G1 A t +` &'" w i 11 �a . s E+ -T-p kpL% J P-•ye arn, N t-o Qv ee*,/Q* +v b ov s w ud ace 3 +nr ►A� Op, 3 . N • co r4cs \A �Sue-et `�, � 5c� .g�+�w�, l S l ►� a w.�cl P+v R�-1 �..5 i- w � `� �- �-�. � \ F� CITY OF E D M O N D S HARVE H. HARRISON MAYOR CIVIC CENTER - EDMONDS, WASHINGTON 98020 - (206) 775.2525 FIRE DEPARTMENT January 18, 1983 Attention -Robert S. Vrooman Association President Sea Vue Condominiums 1130-5th Avenue South Edmonds, WA 98020 Dear Mr. Vrooman, SUBJECT: FIRE AND LIFE SAFETY CODE On January 17, 1983 the Edmonds Fire Department conducted an inspection of your manual fire alarm system and emergency light- ing system. The components of both systems were found. to be in compliance at the time of inspection, except for one emergency light unit. The Edmonds Fire Department commends you and the other owners for your efforts to provide a greater measure of life safety util- izing early detection and warning systems. If we may be of any assistance, please contact this office by calling 775-2525 between the hours of 8 a.m. and 5 p.m., Monday through Friday. Sincerely, Gary . McComas Fire Marshal GLM:PK:be ALARM AUDIBILITY TEST S,E-A . oyz- f OA)oj. Apartment Con ominum Address 192-7-0/9 -Oy7 U.F.I.R. Date Apartment Owner Adress ),6,6W T Ux O0adLl ,J e Er t£ Person Contacted Persons Conducting Test Location(s) of Decibal Recordings) 36� 3�S ALARM PANEL: Yes No Functions properly ' _ Battery Back-up Batteries Functional Ambient Decibals Decibals during Alarm Test 6y 63 ALARM ACTIVATED BY: Smoke Detector Location Pull stations VERIFICATION OF COMPLIANCE FOPST # 423-018-007 RECEIVED [v O V 1 1982 EDMONDS FIRE DEPT., This form must be completed and returned to the Edmonds Fire Department within thirty days. 1. Smoke detector installed ..............Yes ✓ No 2. Self -closures installed...............Yes ✓ No 3 . - Fire -rating on doors : a. 20 minute label..................Yes No z b. 1 3/4" solid core................Yes / No p t on_ o Name ) GO 'S &� Address Z S'U zw Aut orize Signature Phone Number. We wish to thank you for your time and attention in completing this form. s� CITY OF EDMONDS CIVIC CENTER • EDMONDS, WASHINGTON 98020 • (206) 775.2525 CITY ATTORNEY November 10, 1982 Mr. Robert S. Vrooman Association President Sea Vue Condominiums 1130 5th Ave. S. Edmonds, WA 98020 HARVE H. HARRISON MAYOR RECE_1 VE►3 NOV 1 u .EDMONDS FIRE DEPT. Re: 'Fire Code Violations Dear Mr. Vrooman: The Edmonds Fire Department has contacted you on several occasions concerning violations of the Uniform Fire Code at the Seavue Condominium, 1130-5th Ave. So., Edmonds, WA 98020. This matter has been brought to my attention because your buildings are still not in compliance with this law in the following respects: Emergency lighting has been installed but is inadequate, the alarm system has not been up -graded to an acceptable level, and eight unit doors have not had self -closing devices installed. I am sure that I don't need to elaborate upon the need for compliance with the.Uniform Fire Code. It is a matter of insuring the safety of the occupants of your building. The City of Edmonds is charged with the duty of protecting its citizens from fire hazards and cannot ignore non-compliance with its fire code. Failure to comply with the Uniform Fire Code of the City of Edmonds is a misdemeanor, punishable by up to $500 and/or ninety days in jail. Furthermore, each day that a violation exists constitutes a separate violation subject to these penalties. If within ten days of the date of this letter you have not corrected this violation of the fire code and notified the Edmonds Fire Marshall of your compliance, I will have no choice but to file a criminal citation in South District Court to seek redress of this situation. The City has no desire to bring such charges, however, I am sure you will agree that the City cannot expect others to comply with its ordinances unless it insists upon your compliance as well. Mr. Robert S. Vrooman November 10, 1982 Page 2 By copy of this letter I am requesting that the Fire Marshall notify my office if this situation has not been corrected by the tenth day from the date of this letter. Very truly yours, OFFICE OF THE CITY ATTORNEY Mark A. Eames MAE/mjr cc Gary McComas, Fire Marshall CITY OF EDMONDS CIVIC CENTER • EDMONDS, WASHINGTON 98020 • (206) 775-2525 FIRE DEPARTMENT 11 " TO: Mark Eames Attorney SUBJECT: SEAVUE CONDOMINIUM, 1 FnMONDS. WA 98020 AS WE DISCUSSED FOR YOUR INFO. AS YOU REQUESTED FOR YOUR APPROVAL REMARKS: FIRE CODE VIOLATIONS FOR YOUR FILE HARVE H. HARRISON MAYOR TAKE APPROP. ACTION XXX NOTE AND RETURN OTHER Items not currently in compliance: 1. Emergency lighting has been installed but is inadequate. 2. The alarm system has not been up -graded to an acceptable level. 3. Eight unit doors have not had self -closing devices installed. Most of our correspondence has been with Bob Vrooman. Gary L IcComas - Fire Marshal 3/791v CITY OF E D M O N D S HARVE H. HARRISON MAYOR CIVIC CENTER - EDMONDS, WASHINGTON 98020 - (206) 775-2525 FIRE DEPARTMENT October 14, 1982 Attention -Bob Vrooman Sea Vue Condominium 1130-5th Avenue South Edmonds, WA 98020 Dear Mr. Vrooman, Enclosed is a "Verification of Compliance" form. We are re- questing that you complete and return this form. The completed form will be a signed document stating that all units in your building comply with the City of Edmonds Fire and Life Safety Code regarding the three items listed. We are sending this letter rather than inconvenience all of the residents of your building to an inspection. If we may be of any assistance, please contact this office by calling 775-2525 between the hours of 8 a.m. and 5 p.m., Monday through Friday. Sincerely, Gary L. McComas Fire Marshal GLM:be VERIFICATION OF COMPLIANCE FOPST # 423-018-007 This form must be completed and returned to the Edmonds Fire Department within thirty days. 1. Smoke detector installed..............Yes No 2. Self -closures installed...............Yes No 3. Fire rating on doors: a. 20 minute label..................Yes No b. 1 3/4" solid core................Yes No pt on.o Name Address Authorized Signature phone Number. We wish to thank you for your time and attention in completing this form. CITY OF E D M O N D S HARVE H. HARRISON MAYOR CIVIC CENTER • EDMONDS, WASHINGTON 98020 • (206) 775-2525 FIRE DEPARTMENT September 22, 1982 Attention -Robert Vrooman Association President 1130-5th Avenue South Edmonds, WA 98020 Dear Mr. Vrooman, SUBJECT: REVISION IN THE FIRE AND LIFE SAFETY CODE On March 17, 1982 a letter was sent informing you of a revision to the City of Edmonds Code that.pertains to Fire and Life Safety. The amended Community Development Code, Section 19.75.000, provides a specific date.of compliance. Ordinance #2290 states, "Fire alarm systems (automatic, manual) required by this section shall be installed in all buildings specified by the Uniform Fire Code, whether exist- ing or new, by July 1, 1982. We sincerely appreciate the work that has been done on the emergency lighting system. But it has been six months since the original letter of notification that a revision in the Community Development Code had taken place, and the alarm system cannot be overlooked. An inspection will be scheduled on or about October 21, 1982 to determine compliance with the aforementioned require- ments. If, at that time, there is no significant progress, there will be no choice but to refer this matter to the city attorney. If we may be of any assistance, please contact this office by calling 775-2525 between the hours of 8 a.m. and 5 p.m., Monday through Friday. Sincerely, Gar McComas Fire arshal GLM:be CITY OF E D M O N D S HARVE H. HARRISON MAYOR CIVIC CENTER • EDMONDS, WASHINGTON 98020 • (206) 775.2525 FIRE DEPARTMENT August 19, 1982 Attention -Robert S. Vrooman Association President Sea Vue Condominium 1130-5th Avenue South Edmonds, 14A 98020 Dear Mr. Vrooman, On March 17, 1982 you were sent a letter advising the Association of a revision in the Fire and Life Safety Code. On April 12, 1982 the alarm system was tested and failed to met minimum requirements. Would you please advise this office, in writing, as to the progress in updating the system? If we maybe of any assistance, please contact this office by calling 775-2525 between the hours of 8 a.m. and 5 p.m., Monday through Friday. Sincerely, `1. ' gxeA.07 Gary �? McComas Fire Marshal GLM:be 1019 F"ooul� ..aa.t ,a�ay�ae.r�, C/ CITY OF E D M O N D S HARVE H. HARRISON MAYOR CIVIC CENTER • EDMONDS, WASHINGTON 98020 • (206) 775.2525 FIRE DEPARTMENT March 17, 1982 Attention - Robert S. Vrooman Association President Sea Vue Condonimium 1130 - 5th Avenue South Edmonds, WA 98020 Dear Mr. Vrooman, SUBJECT: REVISION IN THE FIRE AND LIFE SAFETY CODE Due to recent changes in the new Edmonds Community Development Code and Life Safety Code,. the Fire Marshal's Office will be enforcing the following requirement(s). 1. Provide emergency lighting for means of egress. The Fire Department will schedule an appointment when we will test the fire alarm sounding devices to determine if they meet the audibility requirements. Please make arrangements to meet with a representative of the Fire Marshal's Office for further explanation of the change(s) required. If we have not heard from you within 30 days, a representative from the Fire Marshal's Office will be out to reinspect for compliance. If we may be of any assistance, please contact this office by calling 775-2525 between the hours of 8 a.m. and 5 p.m., Monday through Friday. Yours for a safer community through fire prevention, . �1�-LL°awzo-o Gary McComas Fire Marshal CITY OF E D M O N D S HARVE H. HARRISON CIVIC CENTER • EDMONDS. WASHINGTON 98020 • (206) 775-2525 MAYOR FIRE DEPARTMENT REVISIONS IN FIRE AND LIFE SAFETY CODES APT . / CONDO NAME : �MiV uL C - FILE CODE: �-3'� 8 007 ADDRESS: 1130 56—k Age e. S A530C, c-ey wo — GaN - <(Q 71 OWNER/MANAGER: Rr.V►Qrk s. vroorv,mh l/3a S, 5 PHONE REVISIONS: Cl AA nAl, �. PERSON CONTACTED: INSPECTED BY: DATE: 3-- ( SZ REINSPECTIO'N- n DATE TENATIVE : ACTUAL: 6 7JDet�/�a6 oA) 1s6N7'5f,H. S'YSTEr'l;cQZ 9AcK. aj e-.2k•82 1 PAGE I OF MS:1v10/79 ALARM AUDIBILITY TEST Ovkj. o WL ( rn ( m Apartment Con ominum 1 -k -�C) !:� --bI-A j� . S Address cK��5 - -0C)7 U.F.I.R. k 41— /a-- 9 Z_ Date Apartment Owner Adress Qo�o 0,znn 1AA o h) & cps LLisoAJ. D/sE�J Person Contacted 'Person(s) Condtfcting Test Location(s) of Decibal Recording(s) uQ �+ 05z04 Ambient Decibals 5a d�o r�. Decibals during Alarm Test 60 j 6p. ---------------------------------- ALARM PANEL: ALARM ACTIVATED BY: Yes No Functions properly ✓ Smoke Detector Pull stationsl� Battery Back-up Locationoo )L�N�� Batteries Functional Comments: ��`�S Co�1ci ►.�o� b� ��ra�Cc� i� Ur.���O 'R�..L. \ cS�' SAS 2�z �El��t WcClz • ��i I �C t��� � (� - �,oa� � ►:� uJ P S i �J � � s Vt� i -� A ►.� � ?Q;o 9 '�_o _� �5 -� 11� `�, a u1j d s CITY OF EDIVIONDS CIVIC CENTER • EDMONDS. WASHINGTON 98020 (206) 775-2525 COMMUNITY DEVELOPMENT DEPARTMENT November 25, 1981 Mr. Bob Brokaw 501 Colby Everett, WA 98201 HARVE H. HARRISON MAYOR 18 UNIT CONDOMINIUM @ 1130 5TH AVENUE S; PERMIT #780360 As a result of a site inspection on Monday, November 9, 1981, it had been determined that the two-hour area separation walls, as required by UBC Chapter 5, are: not in place. This is a life safety hazard and must be corrected as soon as possible. After a discussion with a representative from ICBO it was determined that the.option of sprinkling along both sides of the fire wall locations would serve as comparable protection. However, this or any other resolution of the problem must be acceptable to the City's Board of Appeals. Enclosed is an application for the Board of Appeals. Please complete and return to the Building Division within 10 days. If there are any questions or you desire assistance in filling out the application, please contact this office. Harold Reeves Building Official HR/cn enclosure cc: City Attorney Fire Marshal CITY OF EDM N®S CIVIC CENTER • EDMONDS. WASHINGTON 98020 (206) 775-2525 COMMUNITY DEVELOPMENT DEPARTMENT October 23, 1981 Seavue Condominium Homeowner's Association c/o Mr. Bob Vrooman, Jr. 1130 5th Avenue S. Edmonds, WA 98020 HARVE H. HARRISON YOR RECEIVED )CT •2 61981 EDMONDS FIRE DEPTH 18 UNIT CONDOMINIUM @ 1130 5TH AVENUE S.; PERMIT #780360 The Building Division is unable to find evidence that the two -.hour area separation walls are installed as required by UBC Chapter 5 at, the above address. Our records indicate that the required wallboard inspection was not called for prior to taping and finishing of the walls. The absence_ of the area separation walls would constitute a life safety hazard. The walls must be in place and inspected prior to issuance of a Certificate of Occupancy for the building. Also these building code items must be completed prior to final approval: 1. Provide positive drainage in crawl space -- no standing water permitted. 2. Remove all form material and wood scraps from crawl space. 3. Provide nuts for anchor bolts in -crawl space area. 4. Catch Basin in west driveway vicinity (4th Avenue S.) to have intake pipe chipped back and catch basin grouted. Use or occupancy of the building without issuance of a Certificate of Occupancy from this office is a violation of UBC 307. Please contact the Building Division within 10 days regarding your intentions in this matter. Harold Reeves Building Official HR/cn cc: Edmonds City Attorney Edmonds Fire Marshal certified 4'3-Ole - 007 CITY OF E®IVI®N®S HARVE H. HARRISON CIVIC CENTER • EDMONDS. WASHINGTON 98020 (205) 775-2525 MAYOR FIRE DEPARTMENT January 16, 1979 Robert E. Young Young, Rutledge & Associates 1110 North 175th, Suite 201 Seattle, Washington 98133 RE: 18 UNIT CONDOMINIUM FOR MESSERS, 1130 - 5TH SOUTH, EDMONDS Dear Mr. Young: On January 16, 1979, the Fire Prevention Bureau reviewed plans submitted by you for the above mentioned condominium. Listed below are the Fire Department requirements for your situation: 1. Provide one additional fire extinguisher. 2. Provide one smoke detector in each storage unit. Any overlooked hazardous condition and/or violation of the fire regulations does not imply approval of such -condition or vio- lation. For further information, please contact this office at 775-2525, extension 247. Sincerely, Jack F. Cooper Fire Chief Gary . McComas Fire Marshal GLM/ amm