120 3RD AVE N.PDF1111111111111114600I
120 3RD AVE N
1hc.1B913
CITY OF EDMONDS
121 5TH AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 • FAX (425) 771.0221
DEVELOPMENT SERVICES DEPARTMENT
Planning • Building • Engineering
November 9, 1999
Scott and Marcia Fleury
P.O. Box 6005
Edmonds, WA 98026
SUBJECT: Mixed Use Building Proposal at 120 Third Avenue North
Dear Mr. and Ms. Fleury,
BARBARA FAHEY
MAYOR
This letter is in response to plan concepts submitted to Ray Miller, Development Services
Director, on November 3, 1999. I reviewed the plans with the City Engineer, Jim
Walker, and have the following comments.
Scheme — proposes 19% slope to basement parking with a 20' wide ramp. The City
of Edmonds staff has typically required slopes accessing indoor parking garages to
conform to the street standards as set forth in ECDC 18.80.070. This code section
requires that access slopes not exceed 12% unless the City Engineer grants a waiver
to a maximum of 15%. The width for accessing more than four parking spaces in the
B and C zones is required to be a minimum of 24 feet. ECDC 18.80.010 requires 22
feet of paving plus curbs and gutters, or 24 feet from face -of -curb to face -of -curb.
Scheme — proposes 19% slope to basement parking with an 18' wide ramp. The
City of Edmonds staff has typically required slopes accessing indoor parking garages
to conform to the street standards as set forth in ECDC 18.80.070. This code section
requires that access slopes not exceed 12% unless the City Engineer grants a waiver
to a maximum of 15%. The width for accessing more than four parking spaces in the
B and C zones is required to be a minimum of 24 feet. ECDC 18.80.010 requires 22
feet of paving plus curbs and gutters, or 24 feet from face -of -curb to face -of -curb.
Scheme 3 — proposes 15% slope to basement parking with a 24' wide ramp.
However, the width is reduced to 21' adjacent to the proposed commercial units 101
and 102. The width for accessing more than four parking spaces in the B and C zones
is required to be a minimum of 24 feet. ECDC 18.80.010 requires 22 feet of paving
plus curbs and gutters, or 24 feet from face -of -curb to face -of -curb.
Scheme — proposes access directly off Third Avenue North. The ECDC 18.80.060
specifically eliminates this method. The City staff anticipates that the City Council
will soon be reviewing this section of the code, but the Council has other issues to
resolve before undertaking this review.
• Incorporated August 11, 1890 •
Sister City - Hekinan, Japan
Scott and Marcia Fleury
November 9, 1999
Page 2
It does not appear that the City could approve any of these concepts at this time. If you
have any questions, do not hesitate to contact me at (425) 775-7744.
Sincerely,
I. X----
ORDON C. HYDE
Development Services Engineer
GCH/cmc
c: Jim Walker, City Engineer
Ray Miller, Development Services Director
John Boileau; 5045 Baker Avenue NW; Seattle, WA 99107
\\CrrY2\SYS\ENGR\GORDY\FleuryI.DOC
CITY OF EDMONDS,
GARY HAAKENSON
MAYOR
121 5TH AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 • FAX (425) 771.0221
DEVELOPMENT SERVICES DEPARTMENT
jnc
Planning • Building • Engineering .1890 .
February 10, 2000
Scott and Marcia Fleury
P.O. Box 6005
Edmonds, WA 98026
Subject: Mixed use building proposal at''120 `?°3�d Ave W
Mr. and Ms. Fleury:
This letter is a response to your letter requesting a slope waiver for your parking
area access at the subject address. After reviewing you request with staff,. I
have made the following determination.
The City of Edmonds staff has consistently required slopes accessing indoor
parking garages to conform to the street standards as set forth in ECDC
18.80.070. This code section requires that access slopes not exceed 12%
unless the City Engineer grants a waiver to a maximum of 15%. Because you
are requesting a waiver in excess of the maximum, I am granting a waiver to
15%. As is the case with all staff decisions, you have the right of appeal. If you
wish to pursue an appeal, I recommend that you discuss the appeal procedure
With staff from the Planning Division.
The Traffic Engineer has been assigned to review parking lot standards for
internal parking lots but I do not expect that we will have any modifications to
propose to council for several months. If you have any questions do not hesitate
to contact me. at (425) 771-0220.
Sincerely,
James C. Walker, PE
City Engineer
Cc: Maryanne Zukowski, Traffic Engineer
Ray Miller, Development Services Director
fleury2_.doc
• Incorporated August 11, 1890 •
Sister City - Hekinan. Japan