Loading...
1215 OLYMPIC AVE (4)p4- CITY OF EDMONDS 121 5TH AVENUE NORTH - EDMONDS, WA 98020 PHONE: (425) 771-0220 - FAX: (425) 771-0221 STATUS: ISSUED 09/08/2017 Permit #: BLD20171218 Expiration Date: 03/08/2018 Project Address: 1215 OLYMPIC AVE, EDMONDS Parcel No: 00548900000102 FDMONDS ELEMENTARY GUARDIAN SECURITY SYSTEMS INC GUARDIAN SECURITY SYSTEMS INC C/O SCHOOL DIST 15 EDMONDS C/O FRANK CLOSE C/O FRANK CLOSE 20420 68TH AVENUE W 1743 1 ST AVE S 1743 1 ST AVE S L.YNNWOOD. WA 98036 SF.ATTLF, WA 98134 SEATTLE, WA 98134 (425)431-7000 (206)622-6545 (206)622-6545 LICENSF # GUARDSS233K5 EXP:09/30/2018 JOB 1 1 INSTALL AES RADIO MOMTOR IN THE FACP ROOM VALUATION: $0 PERMIT TYPE Commercial PERMIT GROUP 79 - Fire Alarm GRADING. N CYDS 0 TYPE- OF CONSTRUCTION RETAINING WALL ROCKERY: OCCUPANT GROUP. OCCUPANT LOAD FENCE ( 0 X 0 FT.) CODE OTHER: ------- OTHER DESC ZONE. NUMBER OF STORIES 0 VESTED DATE NUMBER OF DWELLING UNITS 0 LOT # BASEMENT 0 1 ST FLOOR 0 2ND FLOOR 0 IIRO130SLD AREA BASEMENT 0 1 ST FLOOR. 0 2ND FLOOR 0 3RD FLOOR 0 GARAGE. 0 DFCK 0 OTHER 0 13RD FLOOR 0 GARAGE 0 DECK 0 OTHER 0 BEDROOMS.0 BATHROOMS IBEDROOMS0 BATHROOMS:0 FRONTSEFRACK SIDESETBACK REQUIRED: PROPOSED: REQUIRED: PROPOSED IRFQ71RED PROPOSED. LIEIGHT ALLOWED.0 PROPOSED 0 JREQUIRFD PROPOSED 3FTBACK NOTES I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. 09108120,17 Date Released Date ATTENTION IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. CBC109/ IBC110/ IRCI 10. FIRE = APPLICANT = ASSESSOR = CITY STATUS: ISSUED i I i BLD20171218 • Final approval on a projector final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Checkthe job card for all required City inspections including final project approval and final occupancy inspections. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. • Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. • Sound/Noise originating fromtemporary construction sites as a result of construction activity are exempt from the noise limits ofECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all othertimes the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly fi•omtile issuance for this permit. Issuance ofthis pen -nit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. INSPECTIONS THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6) BUILDING 1. Go to: www.edmondswa.gov 12. Then: Senaces 3. Then: Permits/Development 4. Then: Online Permit Info 5: If you don't have one already, create a login (upper right hand comer) 6: Schedule your -ins -ection ENGINEERING (425) 771-0220 EXT._1_326_ Building Department Inspections are now scheduled online. If you FIRE (425) 775-7720 have difficulties, please call the Building Department front desk for PUBLIC WORKS (425) 771-0235 assistance during office hours. (425) 771-0220 RECYCLING (425) 275-4801 When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer morning or afternoon. 0 F-Fire Alarm System Acceptance 0 PROJECT: 26414-1 ESD/Edmonds Elementary 121E Olympic Avenue Edmonds, WA 98020 RECEIVED SEP 08 2011 DEVEI.C� OFTEDMONDS SERVICES R CT g'- IDzvi­7- 121 S EQUIPMENT: TWO WAY PRIVATE RADIO ALARM COMMUNICATOR CODE REFERENCE: NFPA 72, 2013ed I GUARDIAN SECURITY SYSTEMS 1743 Seattle, WA, 98134 P: 206.622.6545 BY: Sacha Lewis DATE: 8 Sept 2017/REV 0 FIRE ALARM COMMUNICATOR TABLE OF CONTENTS SECTION 1: PROJECT NARRATIVE, FUNCTIONS, SUPERVISION, SECONDARY POWER, GUARANTEE, CODE COMPLIANCE, EQUIPMENT LIST/BILL OF MATERIALS, BATTERY CALCULATION SECTION 2: PRODUCT DATA SHEETS AND ARCHITECT SPECIFICATIONS FIRE ALARM COMMUNICATOR SECTION 1 PROJECT NARRATIVE FUNCTIONS SUPERVISION SECONDARY POWER SUPPLY GUARANTEE CODE COMPLIANCE EQUIPMENT LIST/BILL OF MATERIALS BATTERY CALCULATION FIRE ALARM COMMUNICATOR PROJECT NARRATIVE: This is a Two -Way Private Radio Alarm System Communicator, manufactured by AES Intellinet, utilizing a network owned by Guardian Security for the purpose of fire alarm monitoring. FUNCTION: Activation of an alarm, supervisory (if applicable), or trouble condition from the main fire alarm control panel shall cause the following actions: A. Transmit activated condition to the Central Station. B. Initiate specific condition response, per protocols. These 'actions are a one-time action, until the fire alarm control panel initiates a separate additional condition. SUPERVISION: The system is electrically supervised. Trouble conditions shall illicit a trouble condition, sounding a distinct audible signal and an English display of the specific trouble on the main fire alarm control panel, or via local piezo alarm, including but not limited to: a single open or ground in a supervised circuit, shorted signal circuit, antenna or signal loss, low or shorted battery or loss of AC power. These signals will continue until the trouble is corrected. SECONDARY POWER SUPPLY: The system includes a supervised, automatically recharged sealed battery to provide 24 hours of standby and 5 minutes of alarm during a primary power outage, per NFPA. GUARANTEE: The AES System will be warranted for a period of one year (minimum, dependent on contract requirements) from the date of installation being completed and the system being successfully tested!by all authorities having jurisdiction. At the end of the guarantee period, we will offer to the customer either extended warranty contracts or provide on -going non -recurring service calls as needed. It is the customers' responsibility to ensure system maintenance and required testing is performed. FIRE ALARM COMMUNICATOR SYSTEM DEFINITIONS: AHJ: Authority Having Jurisdiction: An organization, office, or individual responsible for enforcing the requirements of a code or standard, or for approving equipment, materials, an installation or procedure. (NFPA72 — 3.2.2) GSS: Guardian Security Systems RAT: Radio Alarm Transmitter (NFPA72 — 26.6.3.3.2.1) RARSR: Radio Alarm Repeater Station Receiver (NFPA72 — 26.6.3.3.2.1) RASSR: Radio Alarm Supervising Station Receiver (NFPA72 — 26.6.3.3.2.1) Supervising Station: (aka Central Station) A facility that receives signals from protected premises fire alarm systems and at which personnel are in attendance at all times to respond to these signals. (NFPA72 — 3.3.194) System Unit: The active subassemblies at the supervising station used for signal receiving, processing, display, or recording of status change signals: a failure of one of these assemblies causes the loss of a number of alarm signals by that unit. (NFPA72 — 3.3.201) FIRE ALARM COMMUNICATOR NFPA72 (2013ed) 26.6.3.3.2 COMPLIANCE: 26.6.3.3.2.1— Independent Receivers The requirements of 26.6.3.3.2(o-c) for a radio alarm repeater station receiver (RARSR) shall be satisfied if the signals from each radio alarm transmitter (RAT) are received and supervised, in accordance with Chapter 26, by at least two independently powered, independently operating, and separately located RARSRs or radio alarm supervising station receivers (RASSRs), or by one of each. At least two separate paths shall be provided from a RAT to the ultimate RASSR. 26.6.3.3.2.1— GSS Satisfaction: Guardian utilizes RARSR's in the Bellingham office, located at 1501 Kentucky St, Bellingham, WA. Guardian Security is not required to provide staffing (per 8.5.3.5) because the following criteria is met: There are 2 RASAR units; both in secure locations within a UL listed area of the building. The RARSR's are powered from different power supplies within the building. The RARSR's both have independent antennas permanently affixed to the roof. The RARSR's are independently operating, and each have a unique subscriber ID. The RASAR to RARSR connection is via fixed IP link. Back up dedicated phone lines should the IP link fail Supervision at Central Station (1743 11t Ave S, Seattle, WA) for communication failure, via proprietary UL listed (as part of AES listing) software. 26.6.3.3.2.2 — Maximum Operating Time The end -to -end operating time parameters allowed for a two-way alarm system shall be as follows: Please see NFPA 72-2013 edition for further text. 26.6.3.3.2.2 — GSS Satisfaction: As part of UL listing on the RAT's, these criteria are met through the manufacturer. 26.6.3.3.2.3 — Supervision: Equipment shall be provided at the supervising station for the supervisory and control functions of the supervision or subsidiary station for the repeater station radio transmitting and receiving equipment. This shall be accomplished via a supervised circuit where the radio equipment is remotely located from the system unit. 26.6.3.3.2.3— GSS Satisfaction: As part of the UL listing of both the manufacturer, and Guardian Security's Central Station, this requirement has been tested and is in compliance. This compliance covers 26.6.3.3.2.3 A-D. FIRE ALARM COMMUNICATOR NFPA72 (2013ed) 26.6.3.3.2 COMPLIANCE (CON'T): 26.6.3.3.2.4—Transmission Channels: 26.6.3.3.2.4(a) The two-way RF transmission channel shall originate with a RAT at the protected premises and shall terminate at the RF receiving system of an RARSR or RASSR capable of receiving transmissions from such transmitting devices. 26.6.3.3.2.4(a) — GSS Satisfaction: This is accomplished within the proprietary software of the manufacturer. RAT's for the network GSS owns are only programmed to communicate with GSS owned RARSR, RASSR or other RAT's. These units ignore or do not acknowledge other RARSR, RASSR, RAT's of networks not by GSS. 26.6.3.3.2.4 — Transmission Channels: 26.6.3.3.2.4(b) A receiving network transmission channel shall terminate at an RARSR at one end and with either another RARSR or an RASSR at the other end. 26.6.3.3.2.4(b)— GSS Satisfaction: See 26.6.3.3.2.1 and 26.6.3.3.2.4 (a) 26.6.3.3.2.4 —Transmission Channels: 26.6.3.3.2.4(c) Operation of receiving network transmission channels shall conform to the requirements of this code whether channels are private facilities, .such as microwave, or leased facilities furnished by a communications utility company. 26.6.3.3.2.4(c)— GSS Satisfaction: This requirement is met through UL testing of Guardian Security's Central Station. FIRE ALARM COMMUNICATOR NFPA72 (2013ed) 26.6.3.3.2 COMPLIANCE (CON'T): 26.6.3.3.2.4—Transmission Channels: 26.6.3.3.2.4(d) If private signal transmission facilities are used, the equipment necessary to transmit signals shall also comply with the requirements for duplicate equipment or replacement of critical components as described in 26.6.4.2 26.6.3.3.2.4(d)— GSS Satisfaction: This requirement is met through UL testing of Guardian Security's Central Station. In addition, Guardian employs locally trained technicians, and has inventoried spare critical components on site. 26.6.313.2.4 —Transmission Channels: 26.6.3.3.2.4(e) The system shall provide information that indicates the quality of the received signal for each RARSR supervising each RAT in accordance with 26.6.3.3.2 and shall provide information at the supervising station when such signal quality falls below the minimum signal quality levels set forth in 26.6.3.3.2 26.6.3.3.2.4(e)— GSS Satisfaction: As set forth in UL Listed proprietary software by the manufacturer, RARSR's are supervised for quality. If the RARSR's fall below UL approved levels (via proprietary software), Central Station is notified via the proprietary software. 26.6.3.3.2.4 —Transmission Channels: 26.6.3.3.2.4(f) Each RAT shall be installed in such a manner so as to provide a signal quality over at least two independent two-way RF transmission channels, of the minimum quality level specified, that satisfies the performance requirements in 26.6.2.4 and 26.6.4. 26.6.3.3.2.4(f)— GSS Satisfaction: The requirements of referenced code 26.6.2.4 and 26.6.4are met via: Units demonstrate FCC compliance labeling All units in Seattle and Bellingham are installed to NFPA70 compliance. All antennas in Seattle and Bellingham utilize single point grounding for protection of the possibility of damage by lightning or static discharging. The requirements of referenced code 26.6.4 are met through UL testing of Guardian Security's Central Station. FIRE ALARM COMMUNICATOR NFPA72 (2013ed) 26.6.3.3.2 COMPLIANCE (CON'T): 26.6.3.3.2.4 —Transmission Channels: 26.6.3.3.2.4(f) 26.6.3.3.2.4(f)— GSS Satisfaction (Con't): The requirements of 26.6.3.3.2.4(f) additionally are met via pre -testing of RAT's are the future protected premises by GSS technicians to determine suitable locations of RAT and its respective antenna. GSS technicians before and after installation, as well as acceptance testing shall verify compliance by communicating with central station and obtaining the proper information. It should be noted that proprietary information is utilized to demonstrate compliance. Proprietary information is acceptable per manufacturers UL compliance. 26.6.1.3.2.5 — System Categories: Two-way radio alarm systems shall be divided into two categories on the basis of the following number of RASSRs present in the system. (1) A Type 6 System shall have one RASSR and at least two RARSRs. (2) A Type 7 system shall have more than one RASSR and at least two RARSRs. (3) Ina type 7 system, when more than one RARASR is out of service and, as a result, any RA Ts are no longer being supervised, the affected supervising station shall be notified. (4) In a Type 6 system, when any RARSR is out of service, a trouble signal shall be annunciated at the supervising station. 26.6.3.3.2.5— GSS Satisfaction: Guardian Security network is a Type 7 system. As such, the compliance of line item (3) notification is automatic, as part of the proprietary software of the manufacturer. Furthermore, procedures are initiated to troubleshoot and rectify any unexpected outages. 26.6.33.2.6 — Loading Capacities: 26.6.3.3.2.6(a) Allowable loading capacities shall be in accordance with Table 26.6.3.3.2.6(a) 26.6.3.3.2.6(a)—GSS Satisfaction: Compliance shall be checked prior to installation. As with other reporting formats (IE DACR Hunt Groups), Guardian Security Systems maintains own compliance. At request of AHJ, Guardian Security Systems can provide documentation of compliance. FIRE ALARM COMMUNICATOR NFPA72 (2013ed) 26.6.3.3.2 COMPLIANCE (CON'T): 26.6.3.3.2.6 — Loading Capacities: 26.6.3.3.2.6(b) If the signal receiving, processing, display and recording equipment is duplicated at the supervising station and a switchover is able to be accomplished in not more than 30 seconds with no loss of signals during 'this period, the capacity of a system unit shall be permitted to be unlimited. 26.6.3.3.2.6(b) — GSS Satisfaction: Guardian Security's Central Station operates with redundant systems, primary and back up functions that record and allow for processing of all signals in real time or queued. Should a failure of any system unit (any subassembly), the redundant unit switchover can be accomplished in less than 30 seconds, where any queued signals are recorded and/or acknowledged. NFPA72 Edition Cross Reference: NFPA72 2010 4 NFPA 72 2007 26.6.2.4 4 8.6.2.4 26.6.4' 4 8.6.5 26.6.3.3.2 4 8.6.3.5 26.6.3'.3.2.1 4 8.6.3.5.1 26.6.3.3.2.2 4 8.6.3.5.2 26.6.3.3.2.3 4 8.6.3.5.3 2 6.6.3:3.2.4(a) 4 8.6.3.5.4.1 26.6.3'3.2.4(b) 4 8.6.3.5.4.2 26.6.3.3.2.4(c) 4 8.6.3.5.4.3 26.6.3:3.2.4(d) 4 8.6.3.5.4.4 26.6.313.2.4(e) 4 8.6.3.5.4.5 26.6.3.3.2.4(f) 4 8.6.3.5.4.6 26.6.13.2.5 4 8.6.3.5.5 26.6.33.2.6(a) 4 8.6.3.5.6.1 26.6.3.3.2.6(b) 4 8.6.3.5.6.2 FIRE ALARM COMMUNICATOR EQUIPMENT LIST: An equipment list, or bill of materials shall be provided to the customer and be part of contract documents. BILL OF MATERIALS: Note: product data sheets may not be available for all parts, Bill of materials subject to field changes. QTY Product ID Product Description 1 7788 AES Fire Communicator 1 7794 AES Intellitap Module J BATTERY CALCULATION: Standby Alarm Standby Alarm Part Number Equipment Qty Each Each Total Total _ (amps) (amps) (amps) (amps) 7*788 Communicator 1 0.17500a 0.80000a 0.17500a 0.80000 7*794 Intelligent Reporting Module 1 0.00500a 0.32000a 0.00500a 0.32000 TOTAL DRAW 0.18000a 1.12000a STANDBY - (DRAW) X (24) HOURS 4.3200 ALARM = (DRAW) X 10 MINUTES (.17) 0.1904 TOTAL ALARM AND STANDBY 4.51amp/hrs TOTAL ALARM & STANDBY WITH 1.2 DERATING FACTOR SECTION 2 �— 5.41amp/hrs FIRE ALARM COMMUNICATOR EQUIPMENT DATA SHEETS ° ° [EalintelfiNet CORPORATION For Alarm Monitoring ° RF Subscriber Unit UL Fire, AA Burglary and NFPA-72 Compliant UL Listed UL Listed Central Station Remote Station 864 Ed, 9, 827, 1610, 365,681 CSFM NFPA RF Section 8.6.3.5 N Advanced !Tireless Alarm Monitoring The 7744/7788 smart subscriber unit links an alarm panel to an alarm monitoring central station. This 2-way transceiver and repeater in one is housed in a full size locking steel cabinet for superior performance. The 7744/7788 supports a wide range of inputs such as NO/NC/EOL and direct voltage. It automatically senses wire and antenna cuts, and monitors battery and AC power status. Advanced status reporting, self -diagnostics and a built-in power supply make the 7744/7788 the first choice for all wireless alarm communication needs. Full Data for Fire and Burglary Use with the optional Firetap for full fire data or the IntelliTap for full fire and burglary data. A�v{b'�Le'Con:fia�ur_a�tior . Av-ailable.-Options 7744 — 4 reversing polarity inputs plus 4 programmable EOL inputs 7788 — Programmable EOL inputs with 8 zones FireTap 7770 IntelliTap 7067 NEMA 4 Enclosure High Gain Antenna Additional Back Up Battery Available in Burglary Beige or Fire Red Options for Full Data for Fire and Burglary o Available in 7744 & 7788 Zone Configurations o Built-in Power Supply and Battery Charger o Local Annunciation Options on Board llsi}0 ., s.ui m NFPA Wireless mesh networking is an innovative technology adopted by many industries with applications that need to communicate data over a large geographic area with a high level of reliability at a low total cost of ownership. The advanced design and 2-way communications capability provides easy installation, expansion, and management when compared to alternative communication methods, both wired and wireless. RF Subscriber Unit Technical Specifications Radio Standard CSAA frequency ranges: 450-470 MHz and 130-174 MHz, VHF and UHF. Others available Standard Output Power 2 wafts (requires FCC license) Power Input 16.5 VAC, 40VA UL listed Class II transformer required Voltage 12 VDC nominal Current 175mA standby; 800mA transmit Alarm Signal Inputs • 4 individually programmable Zones: NO/NC/EOL, trouble restore • RS-232 • Reversing voltage (7744 only) 12 or 24 VDC Operating Temperature Range 00 to 50°C, 320 to 122°F Storage Temperature Range -100 to 60°C, 140 to 140OF . Relative Humidity Range 0-85% RHC non -condensing Back up Battery 12V, 7 AH Low Battery Reporting 22.5-minute test cycle AC Status Reports to central station after approximately 60 minutes without AC power, reports power restored after approximately 60 minutes of restored power. programmable from 60 to 180 minutes Antenna Cut (local reporting) Form `C' Contact 1 AMP Size 13.25"H x 8.5"W x 4.3"D 34cm x 21.5cm x 11 cm Weight 6.4 Ibs, 2.9 Kilograms (excluding battery) Colors Available in standard Burglary Beige or Fire Red Please specify when ordering Available Options • 7788 RF subscriber unit with 8 EOL inputs • 7744 RF subscriber unit with 4 EOL inputs and 4 reverse polarity inputs • 7770 - FireTap • 7067 - IntelliTap • NEMA 4 Enclosure Please specify when ordering AES-IntelliNet' is the industry leader in delivering high quality wireless mesh networks to the fire and security industry in commercial, corporate, government, and educational applications with its broad line of products and advanced network management tools. Users of AES-IntelliNet networks have gained significant rev- enue, communications, and cost advantages while meeting the high standards of reliability required for the fire and security industry. AES-IntelliNet alarm monitoring systems are deployed at hundreds of thousands of locations in over 130 countries. AES IntelfiNet CORPORATION For Alarm Monitoring For more information Call 800-AES-NETS (800-237-6387) AES Corporation 1 285 Newbury Street I Peabody, MA 01960 USA Tel. +1 978-535-7310 1 Fax +1 978-535-7313 1 Email info@aes-intellinet.com Available configurations • 7788, 8 EOL inputs • 7744, 4 EOL inputs w/4 reverse polarity inputs Copyright 2008 AES Corporation AES-IntelliNet is a registered trademark of AES Corporation Web www.aes-intellinet.com W 774417788/02/08 143:0 1 ••`AESe/ nt VetiAES=7794 IntelliPro Firdm CORPORATION For Alarm Monitoring Full Data Module Overview The AES-7794 IntelliPro FireT"' is an add -on module for AES subscribers that enables transmission of full alarm zone data from an alarm panel to a central station over an established AES-IntelliNet network. AES subscribers- • Fire10 can QQ�operate in applications with ort °F ttttltU `t` ® CYO' withoutphone line providing ?Y` gy+,�•,314 emulation of the phone line for the alarm panel communicator. IntelliPro Fire supports most popular alarm commu- nication protocols including Contact ID and " Pulse as well as Modem II and Modem III." Easy Installation IntelliPro Fire easily installs in the subscriber housing and is powered from the transceiver U` module, requiring no additional power connections. AES sub- scribers can be ordered with IntelliPro Fire installed. IntelliPro Fire is easy to program using the AES Handheld Programmer. Features • Commercial fire alarm applications - with or without phone lines • Transmits full alarm data from any Contact ID or Pulse format fire alarm panel • Supports a)panded event reporting from Bosch Modem II and Modem III alarm panels • Universal wireless alarm transmitter - works with most manufacturers' panels • Easy to install in AES subscriber • Easily programs using an AES Handheld Programmer • Option to monitor telephone lines Technical Specifications • Transmits full data to AES receiver using Contact ID or Pulse formats • Formats Supported: Contact ID, Pulse 3+1, Pulse 4+1, Pulse 4+2, Modem Ile", and Modem IIla2• 1/0 Connections • AES subscriber with power • Handheld/PC programming port • POTS incoming phone line • Phone output from alarm panel • Trouble output (form C relay) Size • 2.8 x 5.0 inches (7.1cm x 12.7cm) Power Requirements • 12 VDC nominal, primary and backup power provided by the AES RF Transceiver Unit How to Order Model 7794 IntelliPro Fire 7744F-ULP UL Fire Subscriber w/7794 (4 reversing polarity & 4 EOL inputs) 7788F-ULP UL Fire Subscriber w/7794 Wireless mesh networking is an innovative technology adopted by many industries with applications that need to communicate data over a large geographic area with a high level of reliability at a low total cost of ownership. 'The AES-7794 IntelliPro Fire converts Modem Ile and Modem IIla2 codes to Contact ID for transmis- The advanced design and 2-way commu- nications capability provides easy installa- sion over the IntelliNet network and supports those alarm panels listed in the table located at www.aes-intellinet.com/AES-IntelliNet_70941ntell!Pro.html. This table will be updated as additional tion, expansion, and management when panels are tested. compared to alternative communication methods, both wired and wireless. AES Corporation 1 285 Newbury Street I Peabody, MA 01960 USA Call 800-AES-NETS (800-237-6387) or +1 978-535-7310 1 Fax +1 978-535-7313 1 Copyright 2011 AES Corporation Email info@aes-intellinet.com AES-IntelliNet Is a registered trademark of AES Web www.aes-intellinet.com I Corporation 7794/11/03 SNOHOMISH CO. FIRE PREVENTION �_7 g Serving Brier, Edmignids, and 4­2425 Meridian Ave S'" INSPECTION REPORT Mountlake Terrace Everett, WA 98208 DEDMONDS [3 BRIER Phone (425) 551-1200 0 MOUNTLAKE TERRACE ❑ 0 UNINCORPORATED.FireDistrictl.org www.FireDistrictl.org Fax (425) 551-1272 , 01FREQUENCY STATION & SHIFT LOCATION: 1215 Olympic Avenue 98020 Annual 17-A BUSINESS NAME: Edmonds Elementary School PHONE 4256707374 SCHEDULED DATE DUE ►oNov'2015' MAILING UFIR 0 213 ADDRESS: 1215 Olympic Avenue, Edmonds, WA 98020 BUSINESS OWNER j : Haggen, Brent HOME PHONE: EMERGENCY-1: ESD # 15 HOME PHONE: 4256707000 Z" CURRE KEY ACCESS-2: HOME PHONE: CITY e YES NO EMAIL: BU ESS ❑ L ENSE PERSON CONTACTED: INITIAL INSPECTION DATE NAME OF INSPECTOR: w I IeU [ 2 �•�- FIRE SYSTEMS: FA 7/14 FE 3/14 FID Lk Box Date Last Serviced: .-711 s— -7/15� HAZARDS FOUND AND LOCATIONS COMMUNICATIONS VC 2 2 3 3 4 4 5 5 6 6 7 7 I AGREE TO CORRECT THE ABOVE VIOLATION(S) IN THE NEXT 30 DAYS X 1 st RE -INSPECTION 2nd RE -INSPECTION FINAL RE EXTENSION -INSPECTION VIOLATIONS DATE DUE: DATE DUE: GRANTED TO: DATE DUE: CITED: PERSON PERSON PERSON CONTACTED: CONTACTED: CONTACTED: INSPECTOR: INSPECTOR: INSPECTOR: 2 DATE: DATE: DATE: 3 VIOLATIONS VIOLATIONS.'-.-- PRE -CITATION CITATION ISSUED 5 LETTER SENT NUMBER: 4 CODE 5 2 6 2 6 DATE: SECTION: RETURN RECEIPT 3 7 3 7 RECEIVED 1 6 DISPOSITION: 4 4 8 7 LETTER NEEDED ❑ YES ❑ NO LETTER NEEDED 0 YES 0 NO 6 Serving Brier, Edmonds, and 12425 Meridian Ave S Mountlake Terrace Everett, WA 98208 Phone (425) 551-1200 www.FireDistrictl.org Fax (425) 551-1272 FIRE PREVENTION INSPECTION REPORT M EDMONDS ❑ BRIER ❑ MOUNTLAKE TERRACE ❑ UNINCORPORATED FREQUENCY STATION & SHIFT LOCATION: 1216 01w7mic; iAvariue 98020 Antival 97-D BUSINESS NAME: PHONE: �r SCHEDULED Edmunds ElcfncnlaN School 425E71-1737$ DATE DUE rViv 2014 MAILING UFIR'/J,3 ADDRESS: 1216 Dhlum;L Atimnuc, Edmonds. VVA 98020 BUSINESS OWNER: HOME PHONE: EMERGENCY-1: ESL) g 15 HOME PHONE: 42 CURRENT KEY ACCESS-2: HOME PHONE CITY �V/(�rES NO Pj rc \ e ✓` EMAIL: I,nN F IF,011"-MO(, VAI!r1kit 7.f60 �0l<_-711-`1q) BUSINESS ❑ ❑ LICENSE PERSON CONTACTED: INITIAL INSPECTION DATE �j � � ��---� � �) 1 •1 NAME OF INSPECTOR: 9HE :,•VS 8ENAG: FA 7167 FE 3 JV FD Lk, Raw I HAZARDS FOUND AND LOCATIONS / COMMUNICATIONS •I \ o L.�C't 1 144 2 3 4 L' 5 E' IPA 6 7 AA I AGREE ARECT THE ABOVE VIOLATION(S) IN THE NEXT 30 DAYS X 1sl RE -INSPECTION 2nd RE -INSPECTION EXTENSION FINAL RE -INSPECTION VIOLATIONS DA-E DUE: DATE DUE: GRANTEDTO: DATE DUE: CITED: PERSON I�A' CONTACTED: ' PERSON CONTACTED: PERSON 1 CONTACTED: INSPECTOR: INSPECTOR: INSPECTOR: 2 /, DA -E: 1- 1 U— 152 DATE: DATE: 3 VIOLATIONS VIOLATIONS PRE -CITATION CITATION ISSUED 4 1 ity 5 y` 1 5 LETTER SENT NUMBER: �. 2 1^�}.J�Z:157 2 6 DATE: CODE SECTION: 5 RETURN RECEIPT 6 3 7 3 7 RECEIVED - DISPOSITION: 7 4--- 8 4 18 DATE: LTfER NEEDED ❑ YES MNO LETTER NEEDED ❑ YES ❑ NO 8 FIRE DEPARTMENT COPY f Kevin Zweber From: Hagen, Brett E. (ED) [HagenB@edmonds.wednet.edu] Sent: Friday, March 20, 2015 11:50 AM To: Kevin Zweber Subject: RE: Fire Inspection Edmonds Elem Kevin, Thank you for the note. Our school building does not have an intrusion alarm. We do have a fire alarm panel inside our main school office. The panel is located on the north wall of the office as you enter the two front doors. It is painted black. The panel indicates with small lights locations in the school when alarms go off. If you need further information or would benefit for a school visit, please let me know and I can meet you when convenient. Brett Brett Hagen Principal, Edmonds Elementary School 1215 Olympic Avenue Edmonds, WA 98020 Phone: 425.431.7375 Office: 425.431.7374 Fax: 425.431.7372 Each Student Learning, Every Day! From: Kevin Zweber[mailto:kZweber@firedistrictl.org] Sent: Thursday, March 19, 2015 7:34 AM To: Hagen, Brett E. (ED) Subject: Fire Inspection Edmonds Elem Mr. Hagen, A fire inspection was conducted at Edmonds Elementary on 1/20/15 and no violations were noted. I am emailing because the Fire Crew that conducted the inspection could not locate the Fire Alarm inspection date. know the ESD is very good with life safety maintenance issues so this surprises me. I suspect based on the age of the school that your fire alarm may be tied to an intrusion alarm and because of this, would not require an annual inspection/certification. Could you please answer a few questions: Does the school have an intrusion alarm? Is the fire alarm panel Red? Thanks for your assistance, I would be happy to stop in and help with this issue if necessary. Thanks, 1 Kevin Zweber, CFI Captain/Deputy Fire Marshal Fire Prevention Services Snohomish County Fire District #1/ City of Edmonds Office 425-775-7720 APPLICATION FOR PERMIT FOR MATERIALS OR PROCESSES January 3, 2012 Please verify and correct the following information: Name of Company (DBA): ESD15 Edmonds Elementary School Edmonds Location : 1215 Olympic Avenue In conformity with the terms of the International Fire Code, application is hereby made to store, use places of Assembly Y -Occupant Load: Multi -purpose or maintain the following Room activity, storage or pro- cesses: c/o Edmonds School District #15 Mailing Address: 20420 68th Ave W Lynnwood, WA 98036 EFD UFIR #: (for office use) 2131210254 Your Signature Your Name (print) Your Title Please make corrections, attach $40 payable to the City of Edmonds and mail to: Fire Marshal Department of Fire Prevention 121-5th Avenue North Edmonds, WA 98020 FOR OFFICE USE ONLY Rec'd Z Check# 4* APPLICATION FOR PERMIT FOR MATERIALS OR PROCESSES March 7, 2011 Please verify and correct the following information: APR Ip.FAID EDMONDS FIRE DEPT. Wav- Name of Company; DBA ESD15 Edmonds Elementary School Edmonds Location 1215 Olympic Avenue In conformity with the terms of Places of Assembly - Occupant Load: Multi -purpose Room the International Fire Code, application is hereby made to store, use or maintain the following activity, storage or processes: Mailing Address: Edmonds School District #15 20420 68th Ave W Lynnwood WA 98036 EFD UFIR #: 213121000254 (for office use) Your Signature Your Name (print) Your Title r ��rL�Dr, 1'i-o:1, E►(.S Qr.a�o�i o..S Please make corrections, attach $40 payable to the City of Edmonds, and mail to: Fire Marshal Department of Fire Prevention 121-5th Avenue North Edmonds, WA 98020 CITY OF EDMONDS DEPARTMENT OF FIRE PREVENTION PERMIT January 1, 2011 213-121-000-254 December 31, 2011 Date of Issue UFIR Number Date of Expiration This PERMIT is issued to: I ESD15 Edmonds Elementary School located at: 11215 Olympic Avenue I Edmonds, WA To engage in the business, occupation or process of: And shall constitute permission to maintain, store, use or handle materials or to conduct process which produce conditions hazardous to life or property or to install equipment used in connection with such activities as follows: Places of Assembly - Occupant Load: Multi -purpose Room Allowed Occupant Load: Pursuant to the provisions of the International Fire Code, any violation of the Code may be grounds for the revocation of this PERMIT. This permit does not take the place of any license required by law and is not transferable. Any change in the use or occupancy of premises shall require a new permit. This Permit Must Be Posted At All Times in The Premises Identified Above City of Edmonds Community Development Code 19.25.020 Detection Logic Fire Protection Confidence Test Report DETECTION LOGIC 21312 300' Drive S.E. Suite 130 FIRE PROTECT/ON� fNC� ' ept Bothell WA. 98021 ' s 4"" Y 425-486-2600 FIRE ALARM SYSTEMS PCert (One System per Report) CONFIDENCE TEST ® REPAIRS ❑ Form Revised: 7/2/2007 ification Given RED ElYELLOW ElWHITE Occupancy Address: 1215 OLYMPIC AVE Occupancy Name: EDMONDS LYNNWOOD WA 98036 ELEMENTARY Building Owner: EDSD Responsible Person: GORDON CARSON Phone Number: Phone Number: Building Owner Address: 20420 68T" AVE WEST LYNNWOOD WA 98036 Date of Inspection: 815110 Inspection Type: Annual ® Quarterly ❑ (High Rise OM/) Testers Name: ins____ ADAM FELDMAN SFD Certification Number: SCP-F06437 n-:._a� Central station monitoring? Yes ® No El Monitoring company name: GUARDIAN SECURITY Control panel manufacturer: NOTIFIER Model Number: AFP-200 Problems Found:None BATTERY DURATION TEST: CHARGING UNDER STATIC BOOSTER POWER SUPPLY VOLTAGE LOAD VOLAGE This certifies that this fire and life safety system has been properly inspected for reliability to cover the Items listed in this report and is consistent with Fire Department Fire Code standards, and the discrepancies are noted and have been reported o the building Owner/Man er for corrective action. Signature of Tester: Phone #: 425-486-2600 Testing Agency: DETECTION LOGIC FIRE PROTECTION INC. Mailing Address: 21312 30TH DRIVE S.E. SUITE 103 BOTHELL, WA. 98021 Occupancy Address: 1215 OLYMPIC AVE Occupancy Name: EDMONDS LYNNWOOD WA 98036 ELEMENTARY Building Owner: EDSD Responsible Person: GORDON CARSON Phone Number: Phone Number: Building Owner Address: 20420 68T" AVE WEST LYNNWOOD WA 98036 Date of Inspection: 815110 Inspection Type: Annual ® Quarterly ❑ (High Rise OM/) Testers Name: ins____ ADAM FELDMAN SFD Certification Number: SCP-F06437 n-:._a� Central station monitoring? Yes ® No El Monitoring company name: GUARDIAN SECURITY Control panel manufacturer: NOTIFIER Model Number: AFP-200 Problems Found:None BATTERY DURATION TEST: CHARGING UNDER STATIC BOOSTER POWER SUPPLY VOLTAGE LOAD VOLAGE This certifies that this fire and life safety system has been properly inspected for reliability to cover the Items listed in this report and is consistent with Fire Department Fire Code standards, and the discrepancies are noted and have been reported o the building Owner/Man er for corrective action. Signature of Tester: Phone #: 425-486-2600 Testing Agency: DETECTION LOGIC FIRE PROTECTION INC. Mailing Address: 21312 30TH DRIVE S.E. SUITE 103 BOTHELL, WA. 98021 Problems Found:None BATTERY DURATION TEST: CHARGING UNDER STATIC BOOSTER POWER SUPPLY VOLTAGE LOAD VOLAGE This certifies that this fire and life safety system has been properly inspected for reliability to cover the Items listed in this report and is consistent with Fire Department Fire Code standards, and the discrepancies are noted and have been reported o the building Owner/Man er for corrective action. Signature of Tester: Phone #: 425-486-2600 Testing Agency: DETECTION LOGIC FIRE PROTECTION INC. Mailing Address: 21312 30TH DRIVE S.E. SUITE 103 BOTHELL, WA. 98021 Building Representative (signature): Occupancy Name: EDMONDS ELEMENTARY Date tested: 815110 The items on the checklists below shall be inspected and tested. This list does not constitute all of the required inspecting and testing of the fire and life safety system. Refer to the Fire Department Fire Code for inspecting and testing requirements. Alarm System Functionality Trouble signal with AC power off? N/A ❑ Yes ® No ❑ System operates properly on battery backup? N/A ❑ Yes ® No ❑ Battery voltage (no load) 26.1 volts (Main Fire Alarm panel) Battery voltage (full load) 26.2 volts (signals operating) Charge circuit voltage 26.9 volts System operates properly on standby power? N/A ® Yes ❑ No ❑ All signals operate on AC power? Yes ® No ❑ No. of initiating circuits POINT ID No. of signal circuits 8 Does alarm system .meet audibility standards? N/A ❑ Yes ® No ❑ All circuits checked for electrical supervision? N/A ❑ Yes ® No ❑ All auxiliary equipment operates (Elevators, fans, dampers)? NIA ® Yes ❑ No ❑ Ventilation controls operate? N/A ® Yes ❑ No ❑ Key to panel available? Yes ® No ❑ Operating instructions at panel? Yes ® No ❑ Trouble indicators function properly? Yes ® No ❑ Remote Annunciator Panels function properly? N/A ❑ Yes ® No ❑ Elevator Call Down functions properly? N/A ® Yes ❑ No ❑ Test record posted at panel? Yes ® No ❑ General alarm automatic time delay (minutes) N/A ❑ Other Devices (Specify) Yes ❑ No ❑ System Devices Total Number of Units in Building Total Number Units Tested Test Results Acceptable 1. Bell, Horn or Speaker Strobe 49 49 N/A ❑ Yes ® No ❑ 2. Audio Devices (Horn/Speakers) N/A ® Yes ❑ No ❑ 3. Visual Devices (Strobes) 13 13 N/A ❑ Yes ® No ❑ 4. Smoke Detectors 44 44 N/A ❑ Yes ® No ❑ 5. Heat Detectors 7 7 N/A ❑ Yes ® No ❑ 6. Manual Pull Stations ,? 2j' ,24 ?. N/A ❑ Yes ® No ❑ 7. Duct Detectors N/A ® Yes ❑ No ❑ 8. Sprinkler Flow Switches N/A ® Yes ❑ No ❑ 9. Sprinkler Supervisory Switches N/A ® Yes ❑ No ❑ 10. Automatic Door Unlocks N/A ® Yes ❑ No ❑ 11. Automatic Door Release N/A ® Yes ❑ No ❑ Communication Equipment Total Number Total Number Test Results of Units in Units Tested Acceptable Building 12. Phone Sets N/A ® Yes ❑ No ❑ 13. Phone Jacks N/A ® Yes 0 No ❑ Renamed Edmonds Elementary in 1990 o tv-6 (D x cn Ft 1-� JUL 2 8 200.5 DEVELOPMENT SERVICES CTR. C-!TY OF EMMOINDS S� I T-- o PUGET ORNE N.89'36'30"W. 405.00 I \ I I I \ II \ II I \ II ml \ II 3I I II b� o$110.00 W — I II I I I \ 3 \ ' to I \ I nb I I � ZI � I N.B9'34.287w. I — — N.89'34.28'W. 435.,0 — — — — — — — / \ � II to , I' \ II _,90.00 l i I N.�.l4.28"W ♦ li L �r.o. N ♦ �I � I / I I A+ ♦ - I / I p N�INUBL NNG C ��n ♦♦ I I C.B. ' �ER14TC /S ' Ali ♦ / �-- .. � -- - -,---- I I RECEIVED 10'JUL 2 8 2005------�----I -�== -_== === == ==—N- �'2 w. eoo>z6 = —= —==_=_ —7T i DEVELOPMENT SERVICES CTR. Ci i i OF EUMONDS ?LAN SCALE: 1".40-0• 1 6 O s U N L d W Vf O E Lu 1�- I SUPPLY UPPER LEVEL LOWER LEVEL BUS LOADIYG