Loading...
1520 MAIN ST.PDF11111111111111 14206 1520 MAIN ST 1-750 SEWAGE DISPOSAL PERMIT Septic Tank ...1..-......5J0 .............gals. CITY OF E D M O N D S No...C., ...... Disp. Field...-..525..............sq. ft. Department of xhlj" Kolm ngineering Other................................................. THOMAS I E. BELT--------------------------s hereby authorized to install/ repair sewage disposal system at 1520 Main Street ------•--------------------------------------------------------------------------------- .................------------------•-----------------------------......--------------------------------....----------.... Date issued on.......00tober 11� 1967 Permit expires one year from date of issue DO NOT COVER BEFORE APPROVED BY DESIGNER OR SANITARIAN I hereby certify this system was installed under my supervision and control and complies with all provisions of the City of Edmonds Resolutions. Signatureof Installer ............................................................................ Date------.......----------........... ApprovedDisapproved Date ...................•--......------------ ................ ...... By .................................................................................. Remarks: ------------------------------------------------------------------------------------------------ ------------------•-----------------------........-...-................-.-....---------------------------------- SANITARIANOR DESIGNER ................................................................................................ Date .......................................................... This permit shall be posted in a reasonably conspicuous place on the lob until inspection has been completed. Call for inspection by City of Edmonds --PR 6-1101 Ext. p2 CITY OF EDMONDS - SU ET FLE DEPARTMENT OF PUBLIC WORKS 250 Fifth Avenue North, Edmonds, Washington SEPTIC TANK INSTALLATION PLAN (Subnat in Triplicate) ADDRESS OF PROPERTY......./J.. .....l..I./..fC.`......�.:./..a..................... Lot No ....... ��........... Permit No 2../..1.......... ........... Address . f 2... /. ? �H.va.- �v>:. Phone.. )?8 4`7 Builder ....... ..... . - - ...... Address. ........ ............................:................ ...... Phone ...... ............. ----- ./ Designer f2Q/�IV/��/QIU-� '� SdCAddress-324/C/`/,�..� P�87//` / c� N� •,.1.... p Phone...... Installer... j.!//... ¢!V. /Z...----- .... -•---------. Address. 2.L4� �.... r . � �- ry k� A -1 9 P %Z 8 - O z 4- -- T. Phone ----------- •-- I hereby certify the accompanying drawing is an accurate representation of the system installed at the listed address. I also certify all recommendations and restrictions (concerning plumbing stub elevations, maintenance of grades fills surface drains, etc.) listed by me on my sewage disposal system permit application dated ................ 1Q.� .................. have been complied with. I Q Signature of Designer Date TO BE FILLED IN BY CITY ENGINEER ONLY Accepted..........�...�O- ........ Date .. .... ........ .................... NotAccepted Signature of ....................C_........................_D te.......... Sanitarian....f�%-............. ....------- ...........................•........ .7 - Remarks: .... .r...... ......... �'^' INSTRUCTIONS: Use the reverse side of this form for the drawing. Use a scale which will permit the greatest detail and still contain the entire site on one page. ATTENTION HOME OWNER: Your septic tank has limitations! It was designed and installed to care for an average -size family. Over- loading the septic tank or disturbance of the drain -field may seriously impair satisfactory operation. Points to remember: 1. Have your tank checked periodically to see if pumping is necessary (2%2-3 years). 2. Do not channel ground water, surface water, footing drains or downspouts into the tank or drainfield. 3. Do not excavate, fill, place a structure, driveway or. patio in, on, or over the drainfield. 4. Limit toilet fixture disposal to sanitary wastes and toilet tissue. 5. Detergents and bleaches used in normal household quantities will not harm the action of the septic tank and disposal field. CITY OF EDMONDS DEPARTMENT OF PUBLIC WORKS 250 Fifth Avenue North, Edmonds, Washington APPLICATION FOR A SEWAGE DISPOSAL SYSTEM PERMIT (Submit 3 Copies) Permit to be issued to: ------- 7-*jW_f. ........ �5 .... ........ ........ ... ........ For installation at: (street address) ............ /J:.o ........ . ...... ------------------------------------ ............................. Addition or Subdivision ...... 725,Z?, W.X-. ---- - ­4161- - A.� ---------------- Lot.-----?------ Block ..... — ------- Type of Building: New... 4... Existing.---........ Single family residence.-.. X . ................. ...... Number of bedrooms.. Other: (specify type or use ................................................ __ ------------------ .................................................................................. ............. Builder.------- ............. ............... _Address... .. Designer. *4-1VI'ehavol ----------Address... /44...... j ..... .. ...... 0 Soil Log Hole No. 1 ------- 4-r-7 ..................................................................................................... ........ ........... _ .............................................................................. Soil Log Hole No. 2 ........ d.-Il .... 75 ,;, V ... '7 {1414W ..................................... ...................................................................................................................... ................................................................................... Elevation of Water Table, if encountered. (Distance from ground surface) ........axle .............................................. Corrections to control surface water if needed.'._1104VT...- wkoloa ................................................................................ ...................................................................................................... ................................................. ­ ..................... .. 40 Specify if any removing or grading of topsoil in field area..."";4' 7 . ......... '4V ...... a1041014' ;�V_Aaliy ------ 'J a.-, ed al- -ee .................................... ....... .............. Percolation Test Hole No. I —Average Rate........ ...................... ..... (Fall in ininutes/inch-bottom 6" test hole) Test Hole No. 2—Average Rate ....... 7 ------_--------------- .................... (Fall in minutes/inch-bottom 6" test hole) Test Hole No. 3—Average Rate- .............. ........... .. ------ (Fall in minutes/inch-bottom 6" test hole) Average percolation rate on which to base drain field design ........ 911��All�A Date TakenVdl- 0-- .7. Septic tank requirements based on present rules and regulations: REBID, MIDDLETON & ASSOCIATES Septic Tank Size... '/�a° gallons. Consulting Engineers& Land Surveyors Amount of Square Feet Disposal NI -- - --- -- 324 Main St PR B-1171 EDMr6 W;"GTO Signature — Desig ...... ...... Date. ... ----- / ..... .. Disposal - ------ --- 5 .. _- DO NOT WRITE BELOW THIS LINE (To be completed by Issuing Agency) Permit issued (date) ......... !V111§7 .................... .............. Permit Number ----- �Z99 ................................. Remarks: ..........e . Subjct to City Inspection. Approved revised design. ....... ... ............................................................. .... ...................... ............ ........... ..... ................................... ri Reid, Middleton E Associates, Inc. 324 Main Street Edmonds, Washington 98020 Attention: Ken Reid Gentlemen: October 10, 1967 Re: Septic Drainfield Plan Lot 3, Tommv Park Add. #3 The subject plan has been disapproved for the following reasons: 1. Data shown on plan indicate that soil tests were not performed within proposed drainfield area. 2. Without plumbing stub elevation, we cannot determine to what depth the drainfield would be installed in existing grade. If this stub serves the basement area, then drainfield would be placed at too great of depth for placement in permeable soils. 3. Provide soil log data to a minimum depth of 36". If you have any questions on the foregoing, please contact me. Yours very truly, CITY OF EDMONDS RON WHALEY Assistant City Engineer RW/rf Z PLOT. PLAN AND DRAINFIELD DESIGN FOR:- THOMAS E. BELT, 912 TENTH AVE..'N., EDMONDS, WN. .. LOT 3,.ToMMY PARK ADDITION NO: 3, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 25 OF PLATS, ON PAGE 1I1, RECORDS OF SNOHOMISH COUNTY, WASHING'ON. SCALE:. 1 " 20 FEET _ PERCOLATION TESTS SOIL LOG DATA No. RATE L-1 7" TOPSOIL 20" SANDY LOAM 1 5:0 MIN/IN 22" SAND AND ROCKS J 2 7.0 MIN/IN ' 3 11.5 MIN/IN L-2 4" - TOPSOIL AVERAGE RATE 8.0 MIN/IN 31" SANDY LOAM HARDPAN 24-%0 - �?1' PROVIDE 447 SQUARE FEET OF DRAINFIELD'AREA LOT TO BE GRADED TO DRAIN AWAY FROM HOUSE. .• :'//( jf� --� - %>/_?i/G%Elm ': r.' F. OF 72& j/FN /i',/ sF02 f�-Zice'. r.G(// < ; - N 7,1 % y JOB No. 2911 .-fir, r �!: i� t_'•« ` _., `>•r �l��!iy �: -.. Z PLOT PLAN AND DRAINFIELD DESIGN FOR: THOMAS E. BELT, 912 TENTH AVE. N., EDMONDS, WN. LOT 3, TONMY PARK ADDITION NO. 3, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 25 OF PLATS, ON PAGE 111, RECORDS OF SNOHOMISH COUNTY, WASHINGTON. OCTOBER 9, 1967 SCALE: 1" 20 FEET �- iC i• �5 � - � i- ,T PERCOLATION TESTS SOIL LOG DATA NO. RATE L-1 7" TOPSOIL } 20" SANDY LOAM j�E✓RJJl�� �:�/-L��/i 1 5.0 MIN/IN 22" SAND AND ROCKS �.. p"f1%%.� E�. = -7• ( Q ® ` ? 2 7.0 141N/IN 3 11.5 MIN/IN L-2 4" TOPSOIL AVERAGE RATE 8.0 MIN/IN 31" SANDY LOAM •. HARDPAN 4 7.5 Sip � /U " l0�'✓Ji�!-t c T <�. t�/2� �r('� P•2 � -- - -- - - - -, � PROVIDE 447 SQUARE FEET OF GRAINFIELD AREA LOT TO BE GRADED TO DRAIN AWAY FROM HOUSE. i Q 7-17E/J6N 7-W 7,510 A - i T4A4' F02 A11411V ��'/Z. FitC T'�Ej'. Rk:9 10 4E 55 Z .,c C�� j6 ' u///,E T-00 r/%1- o T"P CT (A cc fS /o,44)) 7-111,� ,cc�,e ef�-7 - PE�SED /0/1O/-7 r.--AfSUMfD - � D A T V INN � 3a1i MAIN' TS�V' '%-PNOG, WAS' JOB NO. 2911 • - 2 Y0. L L RM v , r 7"�CT A (! CC Ef 5 PM40) • PLOT PLAN AND DRAINFIELD DESIGN FOR: THOMAS E. BELT, 912 TENTH AVE. N., EDMONDS, WN. i LOT 3, TOMMY PARK ADDITION NO. 3, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 25 OFIPLATS, ON PAGE 111, RECORDS OF SNOHOMISH COUNTY, WASHINGTON. 1 OCTOBER 9, 1967 SCALE: 1" 20 FEET I i - PERCOLATION TESTS SOIL LOG DATA No. RATE L-1 7" TOPSOIL I 20" SANDY LOAM 1' 5:0 MIN/IN 22" SAND AND ROCKS 7.0 MIN/IN 31 11.5 MIN/IN L-2 4" TOPSOIL AVERAGE RATE 8.0 MIN/IN 31" SANDY LOAM HARDPAN PROVIDE 447 SQUARE FEET OF DRAIN LOT TO 8E GRADED TO DRAIN AWAY F LATERALS OF EQUAL LENGTH (36" X 751 LONG) 0 Jos No. 2911