17710 66TH PL W.PDFiiiiiiiiiiii
5229
17710 66TH PL W
Pilchuck Contractors, Incg
Job # 107020298
May 9, 2005
Sheet 1 of 1 Rob Ing is
av3HV
avou
av3Hv
MOM
OVOU
NOT
TO
SCALE
b
(N
ALLOW ACCESS
TO DRIVEWAYS
4
QQ
-j
%0
Notes:
1. All signs and spacing to conform
to the MLITCD and City of Edmon6s
Traffic Control specs. 4
2. Channelizing devices are 28",;,
traffic cones.
3. All signs are 48" x 48" B/O unless
otherwise specified.
4. Alert affected residents.
5. Work to take place between 9 a.m.
And 4 p.m.
6. Work area will be 60' N of C/L of
66 P1 W & 151 W of C/L of 66 PI W.
WORK
AREA
3'x 5'
U ROAD
04 AHUD
ROAD
HU
4AD SHORT CUL DE SAC
USE MAXIMUM SPACE
ROAD AVAILABLE FOR SIGNS
WORK
AHEAD
172nd St SW �Dpnnvl:D AS"��'—Tr-r)
BY ENGINEERING
4-
Date:
CHANNELIZATION MACE SPACING
MPH
TAPER
ITANGENT
50/70
40
80
35/45
30 �±60(03
LEGEND
28" TRAFFIC CC
WORK AREA
TRAFFIC FLOW
WORK VEHICLE
SIGN LOCATIOIS
I ZDAW I '. I - I
SCALE: 0 - 50'
PROPOSED 2" MPE—IP MAIN
N CA
2" X 90 MPE ELL
— , N. _'W CA
10
PROPOSED 2" MPE-IP MAIN
15'WCA
3:
i
FUSE TIE—IN
59-N. 15-W CA
0
z az
in LO
EX. 5/8" 54'N 4
4
T Ln
17 ST SW
EX. 2" MPE IP 12'S
— 112'W
07008018-00 -Tl-6-7020098-04
070080
50'
R/W
CROSS SECTION A -A
PROPOSED 2* GAS MAIN
15'W CA
NOT TO SCALE
40- R/W
20' 20'
15' 15'
PAVING PAVING
EX. WATER
,P ��
1P
PROPOSED 2" MPE-IP MAIN
---'E CA
2" MPE CAP
__'N. ----'E CA
60'
iR/W
C14
XQ
0
Z
STANDARD GAS CONSTRUCTION NOTES:
I. FIELD LOCATE ALL UNDERGROUND UTILITIES. EXCAVATOR TO CALL mONE-CALLO TWO WORKING DAYS PRIOR TO
TO CONSTRUCTION19 IN WESTERN WASHINGTON CALL: 1-800-424-5555. IN KITTITAS COUNTY CALL: 1-800-553-4344
2. NOTIFY APPROPRIATE PERMITTING AGENCY PRIOR TO JOB START (SEE PERMIT REQUIRMENTS I.
3- ALL CONSTRUCTION IS TO CONFORM TO PSE GAS OPERATING STANDARDS AND GAS FIELD PROCEDURES.
4- EROSION AND SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE 0150-3200 TECHNIQUES FOR TEMPORARY
EROSION AND SEDIMENT CONTROL AND ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
S. NOTIFY PROPERTY OWNERS ADJACENT TO PROPOSED CONSTRUCTION ACTIVITIES A MINIMUM OF TWO WORKING DAYS
PRIOR TO BEGINNING CONSTRUCTION. USE ISI TO DISTRIBUTE FLYERS IF JOB IS LARGE, OTHERWISE HAND
DELIVER FLYERS BE SURE TO INCLUDE THE LIST OF FREQUENTLY ASKED QUESTIONS AND INFORMATION ABOUT
THE OPPORTUNITY TO PURCHASE AN EXCESS FLOW VALVE WHEN THEIR SERVICE IS INSTALLED OR REPLACED
PER GAS OPERATING STANDARD 2550.1600. ALLOW ADEQUATE TIME FOR CUSTOMER DECISION AND RESPONSE.
6. ANY CHANGE IN ROUTE. PIPE SIZE/TYPEs TIE-IN METHOD OR ADDITIONAL MAIN FOOTAGE MUST BE APPROVED BY
THE APPROPRIATE PSE ENGINEER OR PSE REPRESENTATIVE.
7. COMPLETE OPIPE CONDITION REPORVON ALL METAL IC PSE FACILITIES. CHECK BOX ON REPORTFOR WIRE
BOX (TEST LEAD) INSTALLATION.
8. PIPELINE MARKERS AND WARNING SIGNS SHALL BE INSTALLED AND RECORDED BY THE CONTRACTOR PER PSE GAS
OPERATING STANDARD 2525-2500.
9. INSTALL MAIN VALVES OUT OF TRAFFIC WHERE POSSIBLE. VALVE MARKERS SHALL BE INSTALLED AND RECORDED BY
THE CONTRACTOR PER PSE GAS OPERATING STANDARD 2525-2600 FOR ALL HP VALVES IF THE LOCATION IS
NOT READILY ACCESSIBLE, AND FOR ALL VALVES WHERE PERSISTANT SNOWFALL MAY OBSCURE THE VALVE BOX.
10. TO PREVENT ACCIDENTAL OVERPRESSURE OF ADJOINING SYSTEMS, NO TWO MAINS SHALL BE CONNECTED EXCEPT AS
SHOWN ON THIS DESIGN UNLESS APPROVED BY APPROPRIATE PSE ENGINEER OR PSE REPRESENTATIVE.
11. SYSTEM MAOP DENOTED BY:JSYSTEM MAOP - IS- PSIG
12- GAUGE AND MONITOR USE OF ALL STOPPERS TO ENSURE ADEQUATE FEED.
13- RESTORE ALL DRIVEWAYS SUBJECT TO OPEN CUT TO ORIGINAL OR BETTER CONDITION.
14. PURGE POINTS AND PRESSURE TAPS TO BE INSTALLED PER PSE GAS OPERATING STANDARDS 2525-3300, AND 2525.1200.
15- MAINS AND SERVICES SHALL BE TESTED AND PURGED PER PSE GAS OPERATING STANDARDS 2525.3300 AND 2525-3400.
16. IF METALLIC PIPE IS INVOLVED, COORDINATE INSTALLATION WITH CP TECH.
N/A ------------------- PHONE ------ M8 -------
17- NOTE ALL ACTUAL FOOTAGE, LOCATION AND MATERIAL CHANGES ONITHE AS -BUILT IN RED. DENOTES
FOOTAGE BETWEEN FITTINGS.
FITTER (Check Box if Complete)
• WORK AREA LEFT IN CLEANISAFE CCNDITION. El
• COMPLETE ALL PIPE TABLES AND GAS PRESSURE STAMP. El
• FIELD CHANGES RED -LINED ON AS-BIJILTS. El
• MATERIAL VERIFIED AND CHANGES NCTED ON PAPERWORK. El
• ALL VALVE AND TIE-IN LOCA77ONS NOTED ON AS -BUILT. 171
• NOTE BFGINNING OF MAIN, EOM,& LINE OF MAIN LOCATIONS. El
• SHOW ROPE LOCA77ONS & CUL-DE-SXC RADIUS El
Fitter's Signature
Company DATE
GAS MAIN INSTALLATION/RETIREMENT
TypeNVork
pipe
size
Type
Estimated
Length
Actual
Length
Manufacturer
INSTALL
Z.
MPE
250'
114
i
I
GAS
MAIN PRESSURE & TESTING
TYPE TEST
PRESSURE
TESTED BY
DATE ON
TIME ON
DATE OFF
TIME OFF
TYPE TEST
PRESSURE
TESTED BY
DATE ON
TIME ON
DATE OFF
TIME OFF
[Design Press 60
ISYS MAOP 45
PROJECT PHASE
NOTIF#
ORDER#
V)
SAP Superior
Service/Meter
Service/Meter
Service/Meter
Service/Meter
Ind. Service
Ind. MSA
Dis. Reg./FT
HP Svc/MSA
Relocate
Retirement
X192772772
107023536
X192773356
106151561
X192792639
X192714391
Contractor. CONSTRUCTION COST CODES:
051-103-1 1 1 1
Project Manager Contact Information:
KIM GRAY
CELL: 425-290-2678
klm.grayapse-oom
WORK SITE
Owner / Developer Contact Info
MICHAEL MCCARTHY
17710 66 PL W.
EDMONDS, WA 98026
A . TTN: MICHAEL MCCARTHY 425-745-4766 office
CALL (800) 424-55551
2 BUSINESS DAYS BEFORE YOU DIG
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF FACILITIES
F c
4
�0
rn
tn
Cn
Cf
Permit No:
City of fdaidnds,"
RIGHT-OF-WAY CONSTRU CTION PERMIT Issue D��:_
A. Address or Vicinity of Construction:..... t -7!7�7 10
B. Type of Wc -C tt")
)rk (be specific)- x
�z C, M 3 0 9 AJ 1� VQ LA-04- EA I --(A S At C11
C. Contractor: 1(" Y A i AQ 11--`\ �_Q Y I T 'N
U� L)
-Mailing Address:_17),4)an � S �0 Ar A
State License #: 2� LC Lr 151 Y11
City Business License. #:
D. Bt4ilding Permit # (if applicable):
'Kim �Av
Contact:�
9
Phonex2c)(o-q, R-4aal
Liability Insurance: Bond:$
SiVe"L-S--e-w'e'I-PX.P�P�Pap',�ica-9f�:
E. F� Commercial F] Subdivision "El City Project [-I EUC (PUD, VERIZON, PSE, COMCAST, OVWSD)
F� Miilti-Fan-ffly [�[�Single Family F-1 Other
INSPECTOR:
F. EkVEMENT CUT: El YES F� NO G. SIZE OF CUT x
CONCRETE CUT: El YES F1 NO
G. El Mail Approved Permit Call for Pickup
APPLICANT TO READ AND SIGN
INDEMNITY. Applicant understands by hislher signature to this application helshe holds the City of Edmonds harmless from
injuries, damages or claims of any kind or description'whatsoever, foreseen or unforeseen, that may be made against the City of
Edmonds or any, of its departments or employees, including but not limited to the defense of any legal proceedings including defense
costs and attorneyfees by reason ofgranting this permit.
THE CONTRACTOR IS RESPONSIBLE FOR WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FOLLOWING THE FINAL
INSPE CTION AND ACCEPTANCE OF THE WORK ESTIMATED RESTORATION FEES WILL BE HELD UNTIL THE FINAL STREET PATCH IS
COMPLETED BY CITY FORCES, AT WHICH T1MEA DEBITOR CREDIT WILL BEPROCESSED FORISSUANCE TO THEAPPLICANT.
Traffic control and public. safety shall be in accordance with City regulations as required by the City Engineer. Every
flagger must be. trained as required by (WAC) 296-155-305 and- must have certification verifying completion 'of the
required training in their possession.
Restoration is to be in accordance with City codes. All street -cut tr
rch work shall be patched with asphalt or City -
approved material prior to the end of the workday - NO EXCEPTIONS.-,
Three sets of construction drawings of proposed work are required with the permit application.
CALL DIAL -A -DIG (1-86,9742.,4,75,555),,P�,,WO"lp, BE.GINNING WORK
I HAVE READ THE ABOVE STATEMENTS AND UNDERSTAND THE PERMIT REQUIREMENTS AND ACKNOWLEDGE
THA T I MUST MAKE THE PINK COPY OF THE PERMIT A VAILABLE ON SITE A T ALL TIMES FOR INSPECTIONS
Signature: gJ Date:
1W =:I, z AA k,
(Contractor or Agent)
USEONLV.�!
0 C V
`R,ight,-�of*,�a
'Approved by: y
Ti'me Authorized:. Void After AJI Disruption Fee/Fun&l 14.*..
VAt
Special Conditions: &A-4 n*spectio_fi,'F'ee:
T ty 40
ota ee. Z-3
eceip't No'. 4
i ��.Iss - ued by
4i;�, -E I r . A AAI-
- he_&
Mal
n.
REQUIRED INSPECTIONS:
,PO IAJ
Call 425-771-0220, Ext. 1326for a 24-hour voic c inspection request line.
FINAL APPROVAL OF PERMITTED. WORK: DATE:
��Clor's Sign,
CADocuments and SettingsTurtisNy Documents\Fomis\Engnrng\ROWpemit_.doc
Re�ised 10/01/03