Loading...
18804 SOUNDVIEW PL.PDFiiiiiiiiii lill 14437 18804 SOUNDVIEW PL 0 , A . 6 ADDRESS: TAX ACCOUNT/PARCEL NUMIBER: BUILDING PERMIT (NEW STRUCTURE): COVENANTS (RECORDED) CRITICAL AREAS: DETERMINATION: El Conditional Waiver 0 Study Required [] Waiver DISCRETIONARY PERMIT #'S: -54 DRAINAGE PLAN DATED: n2L95 PARKING AGREEMENTS DATED: EASEMENT(S) RECORDED PERMITS PLANNING DATA CHECKLIST DATED: SCALED PLOT PLAN DATED: SEWER LID FEE LID #: SHORT PLAT FILE: LOT: BLOCK: SIDE SEWER AS BUILT DATED: SIDE SEWER PERMIT(S) #: GEOTECH REPORT DATED: STREET USE / ENCROACHMENT PERMIT #: FOR: WATER METER TAP CARD DATED: LATEMP\DSTs\Forms\Street File Checklist.doc CAT" BA,51X: &1)5 * I S-30 (o IL TKr%NCW LWNGTH WSUAL) 4P MUNCH COV4M' -7 0 ............................. . ...... _n&iUWK CVE'L TRZNC-H 4PEKF PIP97L rAP TEE W/ 4'Lo% LF-Gs SYSTEM CROSS—SECTION MIRAff I 500X /-., c7 i / r-- i = L --r' LA-YEC� � COVER 3/4*— 1'/2" WASWED G;:ZAV E I 4 01AM FS;ZF P TRENCH CROSS—SECTION SWANDARD DRAINAGE PLAN INFILTRATION SYSTEM PAGE I OF 2 for location I00D!5 50UMOVIEW A, p I a n by phone 776-7459 date- �QAM85 DESIGN DATA Trench Perc LF per Imperm Trench Number Rate 1000 sq.ft. Area Req. NOTES 1. Call Engineering Divisi on (771-3202) . for prebackfill and final inspections. 2. Responsibility for operation and maintenance of drainage systems on private property is the responsibility of the property owner(s). Preventive maintenance consists of preventing soil and other materials from entering trench during construction as well as after construction. Catch basins should be cleaned of floating material and sediment at regular intervals (at least CITY OF EDMONDS May 21, 1985 File No. 02-85-059 Reid, Middleton & Associates, Inc. Engineers* Surveyors* Planners STORM WATER RETENTION CALCULATIONS FOR MR. & MRS. DONAID ROBERTSON on Lot B of Don Robertson Short Plat Ptn. Gov't Lot 3, Sec. 13, T.27N., R.3E.,W.M. EDMONDS, WASHINGTON Based on data provided to this office by Mr. Robertson and conversations with Jerry Hauth, City of Edmonds Hydraulics Engineer, the following calculations and design are for the sizing of a retention, percolation, trench system for the proposed gravel driveway on the above mentioned parcel: Percolation Data: 1.5 min/in is assumed for parcel and is based on the percolation tests located adjacent to the proposed residence. Assumed Design Rate of 2 min./in. Gravel Driveway: Surface area Approx. 3576 sq.ft. @ 0.7 runoff coefficient. Ultimately the drive is assumed to be paved. Infiltration Trench Design: Table 1 (Drainage System Standards City of Edmonds) 2 min/in Perc Rate requires 18 l.f. of trench/ 1000 sq.ft. of impervious surface therefore 3.576 ( 18 ) = 64.4 l.f. required Install 70 l.f. 4" Perf. P.V.C. or ADS in a 21 x 21 x 701 long washed gravel infiltration trench. Depth to the bottom of the trench 36". See attached plan and details for installation location and standards--. The following calculations are for the design of the infiltration trench adjacent to the proposed residence, carport, storage shed and AC Paved driveway: Note: existing storage shed has been included into these calculations. Storage Shed 800 sq.ft., Carport - 200 sq.ft., Residence - 1920 sq.ft. A.C. Paving 1000 sq.ft. Total 3920 sq.ft. Percolation Data: 1.25 min/in verified by city staff Table I requires 14 l.f. per 1000 sq.ft. impervious therfore 3.92 x 14 = 54.88 l.f. required Install 55 l.f. 4" perf. P.V.C. or ADS in 21 x 21 x 55' long washed gravel trench. See site development plan for location of proposed trench. Typical section per city of Edmonds standard plan for infiltration trench. 121 5th Avenue North, Suite 200, Edmonds, Washington 98020 (206) 775-3434 A _17 .' p-, f AZ,4A1 K ,-n va --,o/ UW'rICF_A'rSV PAn-X Z LAYFJZ'5 5' 6C7_10A.1 I Z4' WATER LEVEL OPEN 0 0 f 7-e,w... cA - A .,r N. 40 VF.AJMFIgW pIpp, OR ---QZIAL IVz' MIUUl5 WA-WMV PUWFISLP &KokVaL 10ae-al Al 7 DISHED CAST IRON GFU —REMOVABLE END CAP NEOPRENE GASKET D,eA1,VA6,z-1ee;r' P4AV /gG,-*Z_ axeiw-1 'wy t!5'0Aol.0,-V,0,5 lAoo', L6"CONCRETE BOTTOM TO BE POURED .44 IM 01 Ar-C REID. MIDDLETON & ASSOCIATES. INC. ENGINEERS SURVEYORS * PLANNERS Edmonds, Wash;ngfon 98020 DEt�_ DATE FILE NO. -8, - ofi 6e ir DR. rc ir.o. I H.14�W , $: SCALE 206/77S-3434 sHawr / oF DATE: M" 'j'10 TO: Building Division Planning Department FROIM: Engineering Division Publ ic Works Department SUBJECT: /f/.0 � '/-T After review of the subject Building Permit application, vie have the following col—I'ments Connection to City water system required. 2 Connection to City sanitary sewer system req0red. 3. RI ght-o F-way peraii t requi red for any work on Ci ty property 4. Driveway slope not to exceed 14cf. S. Back,.-iater valve required if-do,,-instairs plumbing is belo,.-i elevation oF upstream man�iol-e. 6. Water and sewer lines to be separated by 10 foot minimum. a I cr :z a I LJ 0 CITY OF EOMONOS civ< c4ftj1A 10400�04. boax SINGLE FAMILY IIULTIPLE COHM(qCIAL ENGINEERING & P R 0 JE.CT C H E C K PU'13LIC WORK8 R E V I E W LI-S-T - - PROJECT AAAE CONTACT NA11C & TELEPHONE NUMBER ADDRESS ACCESS SLOPE AND VEHICLE ACCESS VWKA61 PLA.N STRH T f I L I LEr-41. DESCRIPTION V[RIFICAJION QUII.CLAIMIL)CDICATIONS CASEMENT - PUOLIC/PRIYATf CALCULATE SEWER COMICTIOH If NO LID I SIR (11 PAVING REQUIRED CURB AHO GUn CR REQUIRED SIDEWALK REQUIRED CUM CUT [OR DRIVEWAY REQUIRED /I R'U'7-of-Wlky CONSTRUCTION PERMIT REQUIRED BOND REQL-IR(O [OR PUBLIC IKPROVEMEIIIS STREET NAME SI GA REQUIRED OTHER SIGmIjjC REQUIRED CXI',Tlti(- WATCR ),.Atli S12[ W)IIR MAIN REQUIRED S(RyICf LINE R(QUIPED 11YOkAlil SHE 11157ING HYDRART RfJUIRED PER FIRE Coot I 1-jo/ S-3-, (A.DOITIONAL COMMENTS m ag SIZE CROSS C(INNECTIO11 INSPECTION WATER lifTER CHARr E UIRED REVIEV BY ---------------- DATE 4 (AXITIOlai. cotKNTs o" v SANITARY SEWR OWING IIUPBER FILE XU118[R w SIDE SEWER AVAILAZILITY -------------- 3: -- SANITAJIY SEWER COIIIECTIOIJ FEE REQUIkED co OPEN DIICH 1XIST111r% >- P.EQUIRLD IX (ULVERI RIWIRED SIZE CAUH BASIN REQUIRED INDICATED M SITE PLAN SMOULDIR DWILAGI )VINIAIN COLLECTION ON SHALE OPEN RUtoff 3LI P(QUIR(D i t INDICATED O.N S17C PLAN c ITID 0 SOIL OND GAU TER FIELD CHECKED 0 PIVI(V By xtw=7= PAT f (ADDITIOUL COWNTS CK SAC C(A I ar . . .......... cw to -AN -To q.K 4 IL :-� E-A-'-r 'N. . A,--, wM4' 1517-* 1 vp"f I WIq 9NLLf -T� T A'a x LUTib UNS u E .30 IDDI tv" A-6 la&O Jl -,TJ4 194.14,5 A "VE�. vi 0 0