19233 83RD PL W.PDF11111111 lill 7767 19233 83RD PL W 890 - 199 - STREET FILE CITY OF EDMONDS 250 - 5TH AVE. N. - EDMONDS, WA 98020 - (206) 771-0220 - FAX (206) 771-0221 COMMUNITY SERVICES DEPARTMENT Public Works e Planning * Parks and Recreation * Engineering September 2, 1993 Mr. Ervin Stitz 19233 - 83rd Pl. W. Edmonds, WA 98026 Dear Mr. Stitz: LAURA M. HALL MAYOR City crews, have identified an obstruction created by trees in front of your residence obstructing easy access to the existing fire hydrant. There is approximately 1' from the trees.to the hydrant and this is too close to the hydrant and the trees need to be relocated or removed Per City Development Code,, 19.75.165; Section D & G (see attached), please remove this obstruction within 30 days and notify this department at 771-0234, extension 349, as soon as this has been completed. If we do not hear from you in this time, the City will remove this obstruction and bill the homeowner for time and disposa'l. Sincerely, zla-&L Ron Holland Water/Sewer Supervisor RH/l k cc: John Westfall, �ire Department Scott Highland, Water.Section Enclosure STITZ/TXTWATER * Incorporated August 11, 1890 0 Sister Cities International — Hekinarf. JAnan 19.75.165 water mains in the public right -of, -way of said streets or highways that are substandard as to size or material according to applicable City standards shall be replaced with ductile iron water mains conforming to applicable City standards and plans. 19.75.165 HYDRANT SPECIFICATIONS A. Flush Type Hydrant. The installation of flush type hydrants (hydrants entirely below grade)*is prohibited. B. Outlets. Fire hydrants shall have two two and one�half inch hose outlets and one four and one-half inch pumper outlet. All outlets ports ' shall have national standard thread, and valve openings no less than five inches in diameter. Fire hydrants shall meet the American Water Works Association, Standard No. C-502. C. Installation, Fittings and Valves. Fire hydrants shall be installed to meet sound engineering practices and to the approval of the Public Works Department, who shall also approve the selection and use of all pipe fittings and valves. There shall be a.foot valve'installed between the service main and the hydrant sufficient to permit the repair and replacement of the hydrant without disruption of water service. The foot valve shall be installed to Public Works Department standards. The location of all such valves installed shall be properly and accurately marked on as -built plans or drawings with generally acceptable engineering detail, two copies of which shall be furnished to the Public Works Department. Valves shall be furnished with a standard valve box. D. Street Grade and Hydrant Clearance. Hydrants shall stand plumb, be setto e.stablished street grade with the lowest outlet of the hydrant at least 18 inches above the street grade and ' at least 36 inches of clear area around the hydrant for cle * arance of I hydrant wrench'on both outlets and on the control valve. The pumper port shall face the street, as determined by the Fire Chief. E. Hydrant Protection. Where needed for hydrant protection from damage, the Fire -Chief may require hydrants to be protected by two or more posts, eight inches in diameter by five feet long, made either of reinforced concrete or steel. F. Existing Hydrants. If there presently exists fire hydrants which do not conform -to these requirements, when replaced they shall be replaced with hydrants which conform. G4. Surrounding Vegetation....,...No person shall plant any, vegetation,. .:,erect. or. -,perform any action which results in.the obstructi:oni.',of a fire hydrant.for a -:distance 2 19 (09/30'/89) 19.75.175 of fifty feet along the immediate route of approach. The owner -occupant of any area in which a hydrant is located shall be responsible for removing weed and tree growth from around the hydrant for a distance of not less- than five feet. The purpose of this sectio-n- is to maintain clear approach and visual area around the hydrant. H. Installation and Approval. The installation of the fire hydrants and mains may be accomplished by . contract or Public Works Department employees. All installations are to be approved by the City Engineer. I. Testinq and Flushinq. Following the installation of fire hydrants, all. pipes-,- valves and hydrants shall be pressure tested, purified, flushed and sampled to meet the requirements of the American Water Works Association, Standards No. C-502. 19.75-175 SMOKE DETECTORS IN MULTI -FAMILY RESIDENTIAL BUILDINGS A. All multi -family residential buildings, whether existing or new, containing three or more units, including but not limited to, apartment buildings, condominiums, hotels and motels, whether or not such buildings have kitchen facilities, shall have smoke detection and fire alarm systems installed which comply with Section 212-10 Washington Administrative Code, and, when applicable, Section 14.104(e) of the 1988 Edition of the Uniform Fire Code, previously adopted by this chapter. 'Installation of such devices shall in all respects comply with the provisions of the Uniform Building Codd as adopted. - B. Sounding devices shall be installed on each floor*of each multi -family residential building so that they are audible in all common areas of the building. Sounding devices must be audible in each room of every dwelling unit and at least one such device shall be installed in each unit unless an acceptable alternative is approved by the Fire Chief. To be audible within the meaning of this section, the required sound level, when measured in each room of any dwelling unit or in every portion of a common area, shall be at 15 decibels above the ambient noise level and in no event less than 60 decibels. C. These requirements shall be, and are, a separate enactment and are a direct exercise of the City's governmental police powers enacted to.protect the lives and -safety of its citizens and also to protect property against fire. As such, these provisions are free standing and are not amendments of the Uniform Fire or Building Code, provided however, that no. (09/30/89) 220 NOTICE: -N owa rra ntyOT The -information'shown on the attached map(s) was compiled for use by the City of Edmonds,, its Employees and Consultants. Th,e city of �Edm.onds does not . warrant the accuracy of anything set for.th on these map(�_). Any person or entity -requesting a copy should conduct an independent -ation shown on inquiry regarding the 'nform -t-Fe -map(s), including, but not Hm'ted to, th-e loc'ation of any sewer stub shown. Such sewer stubs may or may* not exist and may or may not exist at the location shown. Neither the r-ity of Edmonds nor its k_1 emp-1-o-yee-s o-r offikce,rs -shal-1 be Ha-b-l-e for the information given on this map(s), nor for ation provided based any one represent upon . said map(s). .1 APPLICATION for TheCl7yofT-.dmonds SEDE SEWER PERMIT NEW CONSTRUCTION C] REPAIRS F-1 OWNER... ...... z ... ) ... / .............................. ADDRESS .... ............................ n & Lyufq PUW EASEMENT No . .......................................... CONTRACTOR ----- ....................................................... PERMIT No.1 LEGAL DESCRIPTION: LOT No . ............... ...................... NAME OF ADDITION ................ ................................... 4 Al, 6 & Approved: A-PpROVED MAY 9 1�51 DATE� .............................................. CITY OVEDMONDS CIVIC CENT ,E&��W-_ATER-SEWE R DEPARTMENT SIDE SEWER'PERMIT Call PRaspect 6-1107 when work is ready for Inspection. (No Inspec- tions Saturday, Sunday or holidays.) N2 2217 ADDRESS .................... Richard A. Dickson ........................................................................................................... ..................................... .OWNER ...... .............................. 83rd Place Ro Allen ....................................... WtbkTRACTOR ......... y .... I ..................... Permission is granted .......... ........... ....... 19 ... 6 7 for .......... ..... I .............. days to REPAIR or CONNECT a side sewer with City Sewers In accordance %ilth application oil file and governing ordinances. ATTENTION IS CALLED TO THE FOLLOWING: NOTE No. 1—Tbe owners of the property may obtain a permit to construct sewer inside property line. A licensed Side Sewer Contractor must be employed to construct side sewer in street area. Do not cover any portion of sewer before It has been inspected. NOTE No. 2—ObtaJn full Information regarding Ordinance 11.16.030 and R . egulations governing side sewers when you get permit. NOTE No. 3—Top of side sewer must have at least 30 Inches coverage at property line and 12 Inches inside property line; minimum grade of 2%. No bends In grade sharper than % will be permitted. NOTE No. 4—Trenches In street must be water settled and surface of street restored to original condition. Contractors shall be responsible for failure due to improper work which may develop within one year of completion. NOTE No. 5—It Is unlawful to alter or do any other work than Is provided for in the permit, or to do any work on the main sewer or Its appur- tenances except to Insert the pipe into the wye.