Loading...
20909 PIONEER WAY.PDFiiiiiiiiiiiiii 12822 20909 PIONEER WAY TAX ACCOUNT/PARCEL NUMBER: e A10 7 BUILDING PERMIT (NEW STRUCTURE): COVENANTS (RECORDED) FOR: CRITICALAREAS:, —DETERMINATION: E]Conditional Waiver ZKtudyRequired OWaiver DISCRETIONARY PERMIT #'S:— 14 i�� —,ZN", DRAINAGE PLAN DATED: — PARKING AGREEMENTS DA: EASEMENT(S) RECORDED F1 PERMITS (OTHER): PLANNING DATA CHECKLIST DATED: 4 SCALED PLOT PLAN DATED: SEWER LID FEE $: SHORT PLAT FILE:---\ SIDE SEWER AS BUILT DATED: SIDE SEWER PERMIT(S) #: GEOTECH REPORT DATED: L STREET USE / ENCROACHMENT PERMIT #:. FOR: WATER METER TAP CARD DATED: LOT: LID #: BLOCK: LATEMP\DST's\Forms\Street File Checklist.doc ci , ty of Edmonds PERMIT NO: PtRMIT EXF RES �)Azlz) Q'Irnr QXW117111 PVIDX41T 0 9 4- LID # Address of Construction: Property Tax Account Parcel No. 0 1 0 0 S� 0 C) Attach copies of all access and -utility easements Verified and Approved b 0 2 q4Z Ck/\ Owner and/or Contractor: — , zf- (jo- N ' . A 110C,14 I I Z L (i Building Permit Kd"&41_& Contractor License #: . - 9) V_ Single Family Multi -Family (No. of Units Commercial (No. of Units F� Public Invasion into City *Right -of Way: 0 Yes No *RW Con strUction Permit Cross other.* '� Private P roperty: FlYes IZNo **Attach legal description and copy of recorded easement. Owner/Contracto'r no dgement, s4atement: Owner or contfactor s gaa=And ack ' wle By signing for this permit I certify that I have read the City's'public handout entitled ide Sewer Specifications, and shall comply with all City requirements outlined therein. �1-2--2-A - 0(4 Date W CALL DIAL -A -DIG (1-800-421.q�,5555) BEFORE ANY EXCAVATION W 9 FOR INSPECTION CALL 425-771-0220 extensiodl __Q_kW_ 24 HOUR NOTICE REOUIRED FOR ALL INSPECTION REOUESTS .... .. FOR OFFICE USE ONLY Permit Fee $A0 Repair Fee $ Issued By: Trunk Charge $ Date Issued: Assessment Fee $ ReceiptNo:A9. City Permit Surcharge Fee A5.00 Total Fees Paid �_-7 75 NOTE: IF JOB SITE IS NOT. READY FOR INSPECTION WHEN INSPECTOR ARRIVES A $45 RE -INSPECTION FEE WILL BE CHARGED. Job Site Ready YES - NO —Date: Initial: Partiallnspection.-JkEge�-MM2�fd 0 11MVIA11d C-r -4 Date&�d_clnitial: Partial Inspection: Date: Initial: FINAL INOtCTION APPROVED: Date: 'Initial: As�built to Street File: t� PERMIT MUST BE POSTED ON. JOB SITE t- White Copy: File Greep Copy: Inspector Buff Copy: Applicant L;temp;bldg;forms;sspennitjlg4/00 E.D* 0 7' 6'- 9. 0 0 0 co) 0 K 0 0 m X 0 � 2-) 0 M 0 z m - -u M c m 0 z r— 0 m m 0 0 z 0 0 -n ;u 0 0 T Z M M ;u 2.5' CITY OF EDMONDS SIDE SEWER AS- BUILT ADDRESS: PERMIT 20909 PIONEER WAY NO: 9949 CONTRACTOR: HOMEOWNER: SCALE: BRANDEL CUST. HOMES ANNA THATCHER I NTS ATE INSPECTED INSPECTED BY: DATE DRAWN: DRAWN BY: 9/20/051J. McCONNELLI 7/27/06 1 J. BRONDER 120909� 10, 77P"ET WALL 4- (;/Q (tv 2' DEEP LAMPHOLE IN DWY 22' BEND 6' y 4.5- DEEP W/ G.I. LAMPHOLE UOVER (;/0 (g) P/L W/ G.I. LAMPHOLE U NOVER PIONEER WAY 0 E.D *, CITY OF EDMONDS SIDE SEWER AS- BUILT 0 A D D R E Z. HOMEOWNER 20909 PIONEER WAY _BRANDEL CUSTOM HOMES 'CALE CONTRACTOR NTS DATE DRAWN PERMIT at 1890 03/24/2005 BY SIBREL 03/30/2005 NO. 9949 A (n N cn cn 0 0 z 0 z —0 0 r- m 7' 0 m u M 0 -4. a cl, 7' rn X > z m 0 X ILI 01--i 2.5' 4' --T 0 c: 0 0 0 T -n X 0-0 ;u m m X z -< m Eq* F EDMONDS SIDE SEWER AS CITY 0 0 ADDRESS HOMEOWNER 20909 PIONEER WAY -BRANDEL CUSTOM HOMES CONTRACTOR SCALE DATE DRAWN 10/27/05 BY SIBREL NTS PERMIT NO. 9949 m 4' 1.5 'm PIONEER WAY CITY OF EDMONDS WATERLINE AS -BUILT ADDRESS HOMEOWNER - 20909 PIONEER WAY _BRANDEL CUSTOM HOMES CONTRACTOR SCALE NTS DATE DRAM PERMJT 03/25/2005 BY SIBREL NO. 2004-1078- /2- In, tu Op CITY ffyl)MONDS WA-rER AS -BUILT a,17, , _.�_ — zo 29 ADDRESS U/ Z9 9 I I too" %4a4��/ .NUMB�R HOMEOWNER t JD- CONTRACTOR' DATE _-72 DRAWN BY �L41 44_9�whl' Earth ConsLdtants, Inc UGeo(echraical Fhglieer' C'Mmias & 01%i�m"Irdl samfis4s Caistftclm TeSM9 & 1CB0 / WAHO 111'S)q'.1WA1 senices 1805 136th Place N. E., Suite 201: B ellevue, WA 98005 Bellevue (425) 643-3780 - Toll Free (888) 739-6670 FAX (425) 746-0860 DAILY. FIELD REPORT Project Job Location )"6-� T14 General Contractor "'P'04E)e L Grading Contractor General Contractor's /'SFH7- Grading Foreman Field Rep. Job No. Page of Report No. Q-MM, 160 7.;-- 'Z Time On Site Time Off Site Date Day of Week �_'/ Y, 3'�' /-/,— /— / "� � Travel -rime Miles Weather /1 C, VS—, I Permit No. Hrs. Charged Visitors Client/Owner itendent Received Unchecked By Checked By Date Are approved Plans/Permits on -site 0 Yes No If No, contact the building department or e xplain below: Project No. Permit No. &, 1?E lul Er-1 ILE& WA L cAl <./ 7-;E 7!:--, /-DAC/ld- 14— 7-�C57— /:­c,7zA1r, C:.,,- /6�7-,f, c_,r 4c.:'7_5 wrrI4 A (<op sHc-wED TPTII-i 7e-- EE ,-K- Nolv- LA//7N �S7-4NL 21-70-0 ?��SF 94Te,1,:11w A:55 LC(io.E_�r,6�6 RECEIVED AN 212005 DEVELOPMENT SERVICES CTR. CITY OF EDMONDS COPY'fo: CONTINUED ON NEXT PAGiE ALL EXPOSED SURFACES TO BE COVERED WITHIN 2 DAYS OWNER/CONTRACTOR IS RESPONSIBLE FOR EFOSION ND DAMA` 10' UTI L I 7r EA51EHMENT MAINTAIN PLAT INSTALLED EROSION CONTROL 3 ADDRE55 Ib (��' - L -CAL E f 5 ; DE5CRIPTION. 0 , �60 51TE AREA: XXXX PIONEER k4Ar LOT 15, MADR.ONA COVE 5,566 5GUARE FEET Z ON I N r--;,: - PLANNED UNIT DEVELOPMENT HEIC�HT CAL(:-,ULATION (BA5ED FROM EX15TINr-., 6,FZZADE) A= 555' 4v D= 555' I425/4= 55-7.00' AVERA&E EX15T]Nc�i, C�RADE= 35'7.00' AC,TUAL BUILDIN6, HEI6.,HT= 552.24' MAXIMUM BUILDIN(� HEI0HT (25') +. 7' FROM VARIANCE #\/-05-104= 502.70' 5UF;Z\/E'rCF;Z TO PROVIDE E3F-Nr-HMAi-Z< M05T APROPRIATE FOR HEIC�HT \/ERIFI(:-,ATION) I PERVIOU5 AREA5 ,4PAZOY, 6v RE51DENr-E V41 1602 SOUARE FEET 12 9'/"'T"' /�<-r/) r-\1RD PORCHES N 89*56'23"LE e r-(Un 0,() 51 re. '1 '0 4-r serro'o , OF tar fowtv J30 ACCEPTABLE TIGHTLIIJETIO 0 12 5 10 15 w J301 356 MATERIAL NAL<NAYS ,APPROVED AS NOTED 9URI IF:91 IF SDR 35 TOTAL BY EN921NEERIqG LOT la I ==:q H 40 556 5OUARE FEET 120 50UARE FEET 100 5OUARE FEET 2,435 SOUARE FEET _.5EE (�ENERAL NOTEI5 5r-ALE. LOT r-C\/EF;ZAr-7E 12 ( LOT C I OVERA&E 15 BA5ED UPON 5596 OF ENTIRE --Fg"'HANCOR PLANNED UNIT DEVELOPMENT) (,w� 1662 SOUARE FEET OF PFZOP05ED LOT COVERA&E /,Vol&*-r65 me-,�&,V-r (INr-LUDE5 5TF;ZUr-TUFP-E, r-OVEREO PORr-HE5, F->Er-r-5 OVER 50 E)n-)Tt-v6 6a4ve- WATER & SEWER INSPECTIONS REQ'D. CALL 425-771-0220 EXT. 1326 APPROVED BY PLANNING ,21 4c- Zone �— 8 _ Comenj FlagLi_ Setbacks Required Actual .2 Front —10, Sides ---s Rear lot Other 11a, L4 �)a- Heig1q 5 ---e 0 6 T4 (e- 0,V 4-/ felt FOOTING DRAINS NOT TO BE TIED INTO - DETENTION SYSTEM RE�tEIVED C 9--tpy DEC - 6 2004 "IT17 ky el �/- L-$"- PERMIT COUNTER cg&�� fwap;R�? a�� Mad rd A 1- 6� C6 V PLANNING DATA 0 ff j , R NAME: 1)rq-,dk( CL,5T�---, -DATE: t I It 70 PLAN CHK#: 0 SITE ADDRESS: ?-Oqoq p�-'d-Ace'- PROJECT DESCRIPTION: REDUCED SITE PLAN PROVIDED?: 0 / No e MAP PAGE: CORNER LOT: FLAG LOT: ZONING: CRITICAL AIREAS DETERMINATION M. 7q 1AStudvReauired:6/mkTJ f0-Qa-171.1P-0d,-M, LJWaiver LJConditional Waiver SEPA DETERMINATION: fAOA15 r�5vfd 3/IY.4� L3 Fee 13 Checklist L3APO list w/ notaried form L3 (Needed for 500 cubic yards of grading, Shoreline Area- site within 200 ft. of Puget Sound or Lake Ballinger) U Exempt SETBACKS: Required Setbacks: Street:__K_LLeft Side: Right Side: Rear: Actual Setbacks: Street: - Left Side: Right Side: Rear: Street map checked for additional setback required? (Yes I No Q DETACHED STRUCTURES: q L3 ROCKERIES: L3FENCEsrr.RELLISES: - K61\e L3 BAY WINDOWS / PROJECTING MODULATION: 0 Vk L3 STAIRS I DECKS: 0 K PARKING: Required: I Actual: LOT AREA: 5W k)6 0�- (-Ovtl.�e � CA t/?fk PC,- 5a BUILDING HEIGHT: Datum Point: 40 1e e/ VrtV Datum Elevation: =Lrot Maximum Allowed: Actual Height: &301- A.D.U.CREATED?: N /Yes) V- 0.3 -(0Y SUBDIVISION: PRO - Oo-L - (7 LEGAL NONCONFORMING LAND USE DETERMINATION ISSUED: OTHER:— V a&L.') o. 7" tv'(4k-1 overOL�e Plan Review Bir NewBPPIamingDataFomLD0C - Pi 0 oEDICAT4bN KNOW Of MEN FIX.11,11ESE IPRESENTS THAT WE. THE UNDERSIGNED OWNER IN FEE SIMPLE AND MORMAMES OF.7HE LAND Mf=�;LA .... C ZDj DO HEREBY ECLAIIE THIS PLAT AND E.I.AIE E STREETS AND EASEMENTS OR ATEWR PUBLIC ----PR;)TF-'l':EFIjUl�fiQ.ENlS .0 AAID IGVi tN THIS PLAT THE USE THEREOF FOR ANY AND ALL PUBLIC 1 PURPO ALSO THE III T"VIA E ALL NECESSARY SLOPES FOR CUTS OR FILLS UPON IEr E THE 'CR-AND TRACTS SHOWN HE $ON. IN THE REASONABLE GRADING OF ALL STREETS SrWN HEREON. ALSC6THE RIGHT 0 ACCESS OVER THE LOTS AND TRACTS TO THE � LITY EASEMENTS AT %NY TME FOI THE STATED PURPOSES. PHOENIX DEOI�4;MENT.JNC.. IN DEDICATING THIS PLAT OF MADRONA COW. HAS DESIGNATED TRACT! 'AS COMMON.OPEN SPACE AND CRITICAL AREA PRO"IEC-14 ljQ95 AND 993 A D. RACTS 9986MD 999 AS CCIAMON OPEN SPACE AND RE REATION TRACTS AND TRACT 996 HE TH t:�A LANDSCAPE BUFFER FOR ME USE AND BENEFIT OF E RESIDENTS OF MAORO14A COVE. THESE TVA�'TS' SO DIES R�GIN,%;EM EDgE .rSpj W I�ATIED HEREBY FOR THE USE OF THE GENERAL PURL' ',* T 'E THE �A "A COVE HOMEOWNER'S ASSOCIATION, AS 4NOUMALY IR E DECLARATION OF.COVENANTS. CONDMONS AND RESTRICTIONS FORC=lf?%WnI:WABLE HERETO AND RECgFDM UNDER AUDITOR'S FILE NO. —, RECORDS aNOHOMISH COUNTY, WASH!NGTON. WHICH DqL44ENTS ARE HEREBY INC.ORRORA�ED MD DE A PART OF NIS PLAT THIS PLAT , IS SUB4-J TO THE.Dt(;-ARAM0N!OF GO N TS CON ITIONS -0 RESTRICTIONS FOR MADRONA COW. APPLICABLE HERETO AP40 REC�qE. U�DER AUlITOR'l FILE NO OHOMISH CWN".-W F�SHINGTON. C R'S C= WHi0H DOCUMENI ARE EjElY INCORqXTE`D D, 'NE,4.�A:�T. NIS IN WNESS WHERE�F, WE HERERT �ft; OUR HANOVAND '"S 'NIS NY OF 2DO4. ;T,.*J(Z,. A WASH PORATION. PHOENIX DEVELOPMEN Ell. ITS: �iaiw igor v I c.V- —Ph ESI A�r-' ASIA EUROPE AMERICAS BANK MADRONA COVE SECTION 19, T.27N., R.4E., W.M. CITY OF EDMONDS SNOHOMISH COUNTY, WASHINGTON APPROVAL$ EXAM;" IS /0 r#'DAY OF I'f'#AC'y 2004. EOMCINO�r CITY ENGINEER EXAMINED AND APPROVED NIS lb"�I` DAY OF 2 004. IDOMSW4:1�1�� OWS PCANNING DIRECTOR OA- EXAMINED NO APPROVED THIS /V DAY OF 04421'fW Z�,dtm�:� 2004. MAYA. CITY Y ONIONDS ATTEST. CITY CLERK HOLD HARMLESS AGREEMENT OWNERS AND ALL PERSONS HAVING ANY PRESENT OR SUSSEOIJEMT OWNERSHIP INTEREST IN THESi LANDS. AND THE SUCCESSORS AND ASSIGNS OF OWNERS OR OMER PARTIES HAVING MY SAID INTEREST. HEREBY AGREE THAT THE CITY OF EDMONDS SHALL BE HELD HARMLESS IN ALL RESPECTS MOM ANY AND A CLAIMS FOR DAMAGES FOR INJUNCTIVE RELIEF WHICH WAY BE OCCASIONED NOW OR IN THE FUTURE TO ADJACENT LAND OR IMPROVEMENTS By REASON OF THE CONSTRUCTION. OPERATION AND MAINTENANCE Or THE DRAINAGE SYSTEM. AND HEREBY WAIVE AND RELEASE THE CITY OF EOUONOS FOR My ACT AND ALL CLAIMS r08 DAMAGES, EXCLUDING DAMAGE CAUSED SOLELY BY AN ACT OR OMISV� OF SAID CITY, AND INJUNCTVVE RELIEF WHIOH THC OWNERS. OR THEM SUCCESSORS OR ASSIGNS, MAY THEMSELVES HAVE NOW OR IN THE FUTURE BY REASON Or THE CONSTRUCTION. MAINTENMCE AND OPERATION OF SAD DRAINAGE SYSTEM. %RESTRICTIONS %% -"I. NO LINES OR WIRES FOR THE TRANSMISSION Of ELECTRIC CURRENT OR FOR TELEPHONE BY USE CATV. FIR OR POLICE SIGNALS OR FOR ONE PURPOSES. SHALL BE PLACED OR EUE ITS PER41TTED TO PLACED UPON AN' L T OUTSIDE THE BUILDING THER ON UNLESS THE SAME SH ALL BE UNDERGROUND OR IN CONDUIT ATTACHED TO THE BUILDING. 2. COND MONS Of APPROVAL MUST BE MET AND CAN BE rcuNo IN THE FINAL APPROVAL ACKNOWLEDGMENTS FOR THE SUBDIVISION LOCATED IN FILES P-2002-172 AND PRO 2002-171. STATE Or WASHINGTON) 3. THE SETBACKS SHO ON THE PLAT MAP ARE VESTED UNDER THIS PRO/rO AL PLA T A Al NO BUILDINGS WILL BE ALLOWED IN THE INDICATED SETBACK AREAS WITHOLIR" V., '4. ) SS. BEING APPROVED. THE BUILDING SETBACKS ARE AS FOLLOWS: COUNTY Or SNOHOMISH ) FRO T YARD ; 10 FEET THAT I KNOW OR SATSFACTORY EVIDENCE THAT WEAR YARD (EXTERIOR) 15 FEET :SCER7FY THE PERS N -0 APPEARED BEFORE ME. AND SAID PERSON -XNOrLEDGED THAJ-ITE6-1— NEAR YARD INTERIOR) 10 FEET Sl GNED , NIS INSTRUMENT. 0. OATH STA TEO NA T WA?. ZED' TO EXECUTE -SIDE YARD (EXTERIOR) 7. FEET ' THE INSTRUMENT AND ACKNOWLEDGED IT AS THE OF PHOENIX DEVELOPMENT. INC., A WASHINGTON CORPORATION - 13'-NE MEt AND ART 7"0' FEET �""GE ' I VOLU F THE USES G N.. N TART ACT OF SU04 PARTY OR AND PURPOSES Eltl..E E TS IT AP-C'MONS FOR L. AND OR WHICHEVER 10-ADJACENT INSTRUMENT. TEEIR E SLOPE. ST _..IT A 0 TECHNICAL REPORT WHICH CONFIRMS REDUCING i ��-tNT _ FEEGTE TO A MINIMUM OF 10 FEET BASED UPON E E 4� DATED: &bII" ZA, 2ad* Et�CFRGM WffAFIV PUBLJO % TRACTS 99j,"D 997 SHALL REMAIN IN A SUBSTANMALLY NATURAL STATE, NO CLEARING. WrATIN CW WAOMMMM . ........... GRADIN,.F NO. DUMPING OR BUILDING CONSTRUCTION OF ANY KIND SHALL OCCUR: (SIGN) KAPM4 A WOOD EXCEJ%l� FOR SPECIFIED TRALS. FENCES. RECREATION EOUIPMENT AND AMENITIES APPROVED CITY OF EDMONDS. (PRINT) My App*~4 tq*'- APIAL 1& 2008 !�.THE 0 . No st &A-N, ON SUCH AS CUTTING, TRIMMING, GRUBBING. OR OTHER P.,SIMMOOD" THE TREES. PLANTINGS AN SHRUBBERY OR THEIR 'C NOTARY PUBL IN AND FOR THE STATE OF 'AM5;A; ROOT STR3�,TURE. SHALL.00CUR WITHOUT THE OTY'S WRITTEN PRIOR CONSENT: WASHINGTON. RESIDING AT —JUMMA&— MY APPOINTMENT EXPIR S ..,."VPT E RaENCY REVOVL TO PRESERVE LIFE OR PROPERTY OCCASIONED By E - OR ---U-M ON OF TH E TREES - ONLY TREE DETERMINED TO BE j.ORTST AR % A.�A�Dqll joy ANV4_CERTIFlE. E ELIGIBLE FOR MODIFICATION STATE OF6fA"#qfA-nM ) COUNTY OF k IWO- ) )SS. CERTIFY THAT I KNOW OR SATSFACTORY EVIDENCE THAT KAIZ&A TjAlt0rmff,4eg- S THE PERSON WHO A�EAREO O,%FORE ME. TANOT SAID PERSON ACKNOWLEDGED THAT SIGNED THIS INSTRUMENT. STATED HA F ON 1�,�&la"09FED TO EXECUTE THE INSTRUMENT AND ACKNOWLEDGED IT AS THE OF ASIA EUROPE AMERICAS BANK, TO BE THE FREE AND VOLU-TA Y ACT OF SUCH PARTY FOR THE USES AND PURPOSES MENTIONED IN THE INSTRUMENT. DATED: FsexAacv -74,acoq (SIGN) (PRIN NOTARY PUBLIC IN AND F WA —.1.14. RESIDING AT S My APPOINTMENT EXPIRES A�ER �007 fMER Cy PRO SION PROVIDED. MEE REMOVAL SHALL REQUIRE ENT%OF . TIVE M �S OF A SIZE.��VRMING TO ECDC 20.12015. LAND-11URVEYCrA, Ct�TIFICAiE N*K&RE81 CERTIFY MAT THIS,SPELCTOOF I-9MAfD J� E* IS BASED UPON AN ACTUAL N Fjqjj�DV SUPIVEY AND M40MSION OP 27 NORTH. RANGE 4 EAST. W.M.. E Gj� RiFIRIEND SSY STATE. STATUTES; I THAT- E DISTANCES. COURSE$ AND ANGLES ARE SH T lIeON C CTL ; THA TIOE MONUMENTS SHALL BE SET AND LOT AND 8L GOR ER SWrBE STAKEDICORRECTLY ON THE GROUND AS CONSTRUCTION Is MLAELTEDIAIIHAT I HAVE FUk?A COMPLIED WITH THE PROVISIONS OF THE STATE AND S TU TIES AND. f�fl MONS GOVERNING PLATMNO. — -------------- T.. REX FEGRASVREYPR SSIONAL LAND SURWYOR CERTITT!;�a DATE IXN,ID, �I- 8 rl?k �t r ) � /6/ EASEMENT PROVISIONS 4ft AN EASEMENT IS HEREBY RESERVED FOR AND GRANTED TO ALL UTILITIES SERVING SUBJECT PLAT -AND THEIR RESPECTIVE SUCCESSORS AND ASSIGNS, THE EXTERIOR 1 0 FEET PARALLEL " A D ADJOINING THE STREET MONTAGE OF ALL LOM TRACTS AND COMMON AREAS, AS SHOW HEREON IN WHICH TO INSTALL LAY. CONSTRUCT. RENEW, OPERATE AND MAINTAIN UNDERGROUND CONDIJIM CABLES. PIPE. AND "RES WITH NECESSARY FACILITIES AND OTHER EOUIPMENT FOR THE PURPOSE OF SERVING NIS SUBDIVISION AND OTHER PROPERTY WN ELECTRIC, TELEPHONE. GAS. TELEVISION CABLE AND OTHER UTILITY SERVIC S TOGETHER WIN THE RIGHT TO ENTER UPON THE LOTS. TRACTS AND COMMON AREAS AT ALL TIMES FOR THE PURPOSES HEREIN STATED. DRAINAGE EASEMENTS DESIGNATED ON THE PLAT ARE HEREBY RESERVED FOR AND GRANTED TO THE CITY OF EDMONDS. EXCEPT THOSE DESIGNATED ON THE PLAT AS PRIVATE EASEMENTS. TOGETHER WITH THE RIGHT OF INGRESS AND EGRESS AND THE RIGHT To EXCAVATE. CONSTRUCT. OPERATE. MAINTAIN, REPAIR MD/OR REBUILD AN ENCLOSED OR OPEN CHANNEL STORM WATER CONVEYMCE SYSTEM AND/OR OTHER DRAINAGE FACILITIES. UNDER. UPON OR THROUGH THE DRAINAGE EASEMENT, AN EASEMENT IS HEREBY RESERVED FOR AND GRANTED TO THE CITY OF EDMONDS OVER, ACROSS ' THROUGH AND UPON THE NORTHWESTERLY 12 FEET OF LOT 5 AND THE SOUTHEASTERLY 8 FEET OF LOT 6. AS SHOWN HEREON. FOR THE OPERAMON AND MAINTENANCE OF UTILITIES; TOGE ER WIN THE RIGHT OF INGRESS AND EGRESS FOR THE STATED PURPOSES. AN EASEMENT IS HEREBY RESERVED FOR AND GRANTED TO THE OTY OF EDMONDS OVER. ACROSS. THROUGH A D UPON LOTS & 9. 10. TRACT 995 AND TRACT 998. AS SHOW HEREON. FOR THE OPERATION AND MAINTENANCE OF A STORM SEWER PIPELINE AND APPURTENANCES; TOGE R WITH THE RIGHT OF INGRESS AND EGRESS FOR THE STATED PURPOSES. AN EASEMENT IS HEREBY RESERVED AND GRANTED TO THE MADRONA COVE HOMEOWNERS ASSOC AMON FOR PEDESTRIAN INGRESS AND EGRESS OVER AND ACROSS THE SOUTH 5 FEET OF LOT 9 AND THE NORTH 5 FEET OF LOT 10. TOGETHER WPH THE RIGHT OF NGR SS AND EGRESS FOR THE MAINTENANCE OF ANY SUCH FACILITIES LOCATED WITHIN THE EASEMENT RIGHT OF WAY. THE PRIVATE DRAINAGE EASEMENT UNDER AND UPON LOTS 6, 7, 8 AND 9, AS SHOWN HEREON, IS HEREBY RESERVED FOR AND GRANTED TO THE OWNERS OF LOTS 6. 7. 8 AND 9 FOR THE PURPOSE OF OPERATING. MAINTAINING AND RECONSTRUCIIING STORM WATER FACILITIES; TOGETHER WITH THE RIGHT OF INGRESS AND EGRESS FOR SUCH PURPOSES MAINTENANCE OF ANY FACTUTIES LOCATED UPON OR VAN THE EASEMENT RIGHT OF WAY HEREIN CONVEYED SHALL BE BORNE JOINTLY AND EOLIALLY BY THE OWNERS OF SAID LOTS S. 7. 8 AND 9. THE PRIVATE MANAGE EASEMENT UNDER AND UPON LOTS 10. 11 AND 12. AS SHOWN HEREON. Is HEREBY RESERVED FOR AND GRANTED TO THE OWNERS OF LOTS 10, 11 AND 12 FOR THE PURPOSE OF OPERATING. MAINTAINING AND RECONSTRUCTING STORM WATER FACILITIES, TOGETHER WITH THE RIGHT OF INGR SS AND EGRESS FOR SUCH PURPOSES. MAINTENANCE OF ANY FACILITIES LOCATED U PON OR WITH THE EASEMENT RIGHT Of WAY HEREIN CONVEYED SHALL BE BORNE JCINTLY AND EOUALLY BY THE OWNERS OF SAID LOTS 40. 11 AND 12. THE PRIVATE ORMNAGE EASEMENT UNDER AND UPON LOTS 19. 20. AND 21. AS SHOW HEREON. IS HEREBY RESERVED FOR AND GRANTED TO THE OWNERS OF LOTS to. to. 2D, 21 AND 2Z FOR THE PURPOSE OF OPERATING, MAINTANING AND RECONSTRUCTING STORM WATER FACILITIES; TOGETHER WN THE RIGHT OF INGRESS AND EGRESS FOR SUCH PURPOSES. MAINTENANCE Or ANY FACILITIES LOCATED UPON OR NN THE EASEMENT RIGHT OF WAY HEREIN CONVEYED SHALL BE BORNE JOINTLY AND EOUAL.Y By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�RVED FOR AND GRANTED TO THE OWNERS OF LOTS 2 1 AND 22 FOR THE PURPOSE OF Sr OPERATING. MAINTAINING AND RECONSTRUCTING SANITARY SIDE SEWER FACILITIES: TOGETHER W TH THE RIGHT OF INGRESS AND EGRESS FOR SUCH PURPOSES. MAINTENANCE OF THE FACUTIES LOCATED UPO OR WNW THE EASEMENT RIGHT OF WAY HEREIN CONVEYED SHALL BE BORNE JOINTLY AND COUALLY By THE OWNERS OF SAW LOTS 21 AND 22, AUDITOR'S CERTIFICATE FILED FOR RECORD AT THIE,�EOUES;,g� PHOENIX DEVELOPMENT, INC. NIS Ay 0 2004 . ----ill=�.I.LITES PAST��.j MG RECORDED 5I.VeA01a;� VOLUME6- Ef=— OF PLATS. PAGES AFN ORDS CORDS OF a Y.. �7 _YSH COUNTY. WASHINGTON. I", Wow ITOR. SNOHOMISH COUNTY DEPUTY COUNTY AkeTCAff AFN a,2azzm&S-my ALTERATION OF A PORTION OF LOTS I AND 2, BLOCK 5. ALDERWOO MANOR NO. -9 (VOLUME 10, PAGE 0) IN SEI/4, SWI/4, SECTION 10, T.27N., R.4E., W.M. LOVELL-SAUERLANO & ASSOCIATES, INC. 19400 33RD AVENUE W., SUITE 200 LYNNWOOD, WASHINGTON 9803a 425.775.la0l LSA FILE NO. 4486 SHEET I OF 6 MADRONA COVE SECTION 19, T.27N., R.4E., W.M. CITY OF EDMONDS SNOHOMISH COUNTY, WASHINGTON LEGAL C48CFtIPTIONS LEGAL DESCRIPTIONS (continued) TITLE ENCUMBRANCES % PARCEL. ll� % PARCEL III: THE FIR PMTY IS SUBJECT TO THE TERMS AND CONDITIONS OF THAT CERTAIN OEASEmENr. . "SLOPE RECORDED UNDER AUDITOR'S FILE NO. 2035737. % % . .... ..... ,,,A; PCRFI�l' LOT 1. �OCK 1, .1DERWOOD A. NO. 1. IN VOL WE ACCORDINGe THE Aj,�HEF�EW U 10. OF THAT PORTION Or THE SOUTH 150 FEET OF LOT 2. BLOCK 5. ALDEPWOOD,NWANOR NO. 9. ACCORDING TO THE PLAT THEREOF, THE PROPERTY 15 SUBJECT TO THE TERMS AND CONDITIONS OF THAT CERTAIN OR OAZDED PLATS.e. COUNTY. WASHINGTON. 6. WE�L DESC21 As FOLLOWS: RECORDED VOLUME 10. OF PUTS. PACE 5. RECORDS OF SNOHOMISH COUNTY. WASHINGTOH. LYING EAST OF PARCEL C OF SLOPE EASEMENT-, RECORDED UNDER AUDITOR'S FILE NO. 2036738. SHORT PLAY 850923033 AND WEST OF COUNTY ROAD SURVEY I2D4; THE FOLLOWING IDESCRIBED PARCELS: THE PROPERTY IS SUBJECT TO THE TERMS AND CONDITIONS OF THAT CERTAIN -SLOPE FILE NO. 2036739. SECINHING AT iW i;;ksEcrmN OF �bUN LINE OF SAO LOT I WITH WESTEr4V'8OUNDAAr OF ODUNTY:ROAD SURVEY No. 1204; EXCEPT EASEUENr, RECORDED UNDER AUDITOR'S ALCNO?OUN LINE (n LOT I FOR 524.06 FEET TO -TM REOF; F BE NWINC AT A PONT ON THE VXSTERLY LINE OF COUNTY ROAD SURVEY NO. WN CH IS 150 FEET NORTH OF. MEASURED AT THE PROPERTY IS SUBJECT TO THE TERMS AND CONDITIONS OF THAT CERTAIN -UTILITY EASEMENT' (STORM SEWER), RECORDED UNDER AUDITORS FILE NO. 51204 RIGHT ANGLE TO THE'SOUTH LINE OF LOT Z IN BLOCK 5 OF 2063005. NO-14LONG WEST UNE-OF LOT I FOR 252 - 15 FEET TO RA COUNTY GAO AILDERWOOD MANOR NO. 9: THENCE SOUTHERLY ALONG THE WESTERLY LINE OF SAID COUNTY ROAD OF THAT CERTAIN 25O.-FEET SOUTH OF 5aUTHFRLY BOUNDARY OF SQRW , Md. 120�: .1. . A . . .. THENO'SOUN 65-26'3j-. EAST 2.IV25 FEET; FOR 75 FEET: THENCE WEST PARALLEL TO THE SOUTH LINE OF SAO LOT 2 FOR 300 THE PROPERTY IS SUBJECT To THE TERMS AND CONDITIONS -UTIUTY EASEMENT' (SANITARY SEWER). RECORDED UNDER AUDITOR'S FILE NO. 2070799. THENCE SOUTH 19-14-57- EA;rVOR 60 FEET TO A POINT ON A LINE PARALLEL TO AN TOO FEFJ NORTH OF SOUTH LINE OF SAO LOT 1; FEET; THENCE NORTHERLY PARALLEL TO SAID COUNTY ROAD FOR 75 FEET TO THE PROPERTY IS SUBJECT TO THE TERMS AND CONDITIONS OF THAT CERTAIN .Q- THENCE. EAS1. ALONG. -SAID PARALLEL LINE FOR 259 FEET TO lTCRlYjWNDARY OF COUNTY RO No, 1 2C - A POINT 150 FEET NORTH OF THE SOUTH LINE OF SAID LOT 2: TH CE EAST " FEET TO THE POINT OF BEGINNIN . -UTUTY EASEMENr (SANITARY AND/OR STORM SEWER). RECORDED UNDER AUDIToR*s FTLE NO. 2070559. THENCE S JTHERLY ACONG SAID WlESlFZ=ARY 07-SAJO COUNTY ROAD FOR 1 06.14 nTT TO POINI'OF SECINNINF, 'OF SAO BEGINNING AT THE INTERSECTION OF SOUTH LINE LOT 2 WITH THE WESTERLY LINE OF THE COUNTY ROAD (SURVEY NO. 1206); THE PROPERTY IS SUBJECT TO THE TERMS AND CONDITIONS OF THAT CERTAIN PARCEL e: . .... ... THENCE NORM 69'51'23' WEST ALONG SOUTHERLY LINE Of SAID LOT U 21 TILITY EASEMENT" (SANITARY SEWER). RECORDED UNDER AUDITOR'S FILE NO. 11570. ALL THAT PORTIA OF LOT i BLOCV. S.'ILM: 'AN 'WZ;.' I"* *&i FOR 300 FEET-. THENCE AT RIGHT ANGLES NORTH 75 FEET. ACCORDING TO To. TOE PLAT NtRf6f. RECOROE 7 PLAM PAGE 6. '%ECORDS OF SNOHOMISH CqPhlry.' A�HINGTO". T, SOUTH SS'51'23' EAST TO WIESTERLY LINE OF SAID COUNTY RGEANCE DESCRIBED AS FOLLOWS: THENCE SOUTHEASTERLY ALONG SAID WESTERLY LINE TO THE TRUE POINT OF BEGINNING, TO AND BEGINNING AT THE INTE�R&Wt% OF t.WRf';ARAU 100 A THE THE OF SNOHOMISH, STATE OF WASHINGTON. AR I& WESTERLY FEET NORTH OF THE SOUTH ?W OF 0) LOT I. BOUNDARY OF THE COUNTY ROAD, SURVEY NQ,-1204: OF SAID THENCE WEST PARALLEL TO THE SOUTH.0 LOT 101,�Sg SITUATE IN COUNTY FEET; �V .1 THENCE NORTH w3e3r WEST FOR 30 FEET; THENCE NORTH 701 r5a' EAST FOb 237.22 FEET WESTERLY .70'THE ,JIM Y TH NDAR OF COUNTY ROAD, SURVEY NO. 12016 FIND �Iplz ENCE SOUTHERLY ALONG SAID WESTERLY ARY OF COU AD 0 OR 71.24 FEET TO THE POINT OF BEGINNIM PARCEL 0 ALL THAT PORTION OF LOT 2. BLOCK 5. R ANOR NO. V* 4.E EI'rACCORDING TO ME PUT THEREOF. N REC=E PUTS, PACE 1. REC DS OF SNONOWLSH ClUNTY. WASU1116C. % LYING WZ OF A LINE 150 FEET NORTH OF ANIN PAPALLQ- TO THE SOUTHOL E THEREOF AND WESTERLY OF COUNTY-51D NO. Q 4. .!I UNDER SURVEY. TREASURER'S CERTIFICATE EXCEPT NAT PORTION CONVEYED TO CHARLES AND PATRICE WLEE. HUSBAND AND NFL By OCED RECORDED UNDER AUDITOR'S.61LE NO. 20D402.1002Y .. ......... 1 HEREBY CERTIFY THAT ALL STATE AND COUNTY TAXES HERETOFORE LEVIED AGAINST THE PROPERTY DESCRIBED HEREIN. ACCORDING TO THE BOOKS AND RECORDS OF MY OMCE. HAVE BEEN FULLY PAID AND DISCHARGED, INCLUDING a0*4 TAXES PARCEL 0.. 140..." 3 -11 - THAT PORTION OF LOT 2. BLOCK 5. ALDCRWOGG MANOR ACCOR INC TO THE PLAT THEREOF. RECORDED IN VOLUME I Cf. OF PLATS, PAGE 6. RECORDS OF SNOHOMISH COUNTY, WASHINCTCN. I % % E06 L -vtAJ;, ., 01 SNOHOMISH COUNTY TREASURER DEPUTY SNOHOMISH COUNTY TREASURER DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE WESTERLY LINE Or COUNTY ROAD % IN ACCUkUANCE WITH RCW j,,.ua­ SURVEY NO. 1204 WHICH IS 150 FEET NORTH OF, MEASURED AT RI ANGLES TO THE SOUTH LINE OF LOT 2. IN BLOCK 5 OF 7 % AN PERSON RECORDING A FLAT AF, A RWDOD MANOR NO. 9; IGH .0. % MAY 31st MUST PAY ADVANCE TAXES 4, THENCE SOUTHERLY ALONG THE WESTERLY LINE OF SAO COUNTY ROAD % FOR 75 FEET; 1% FOY % R TTTF NFYT YF I R. IL Je �,g -b 0 THENCE WEST PARALLEL TO THE SOUTH LINE OF SAID LOT 2 FOR 300 F T: EE TH CE NORTHERLY PARALLEL TO SAID COUNTY ROAD FOR 75 FEET TO .0 ........ < Up --ok" A PONT 150 FEET NORTH OF SOUTH LINE OF SAID LOT 2: THENCE EAST 300 FEET TO THE POINT OF BEGINNING. ....... 8 E PARCEL E: ISH ALL THAT PORTION OF LOT 2. BLOCK 3. AUDERWOOD MANOR NO. 9. ACCORDING TO THE PLAT THEREOF. RECORDED IN VOLUME 10. OF PLATS, PACE 6. RECORDS OF SNOHOMISH COUNTY, WASHINGTON. I DESCRIBED AS FOLLOW& .. % BEGIN ING AT THE INTERSECTION Or SOUTH LINE OF SAID LOT 2 WIN THE WESTERLY LINE OF THE COUNTY ROAD (SURVEY NO. 1204); % THW"CE NORTH 89'31 '23* WEST ALONG SOUTHERLY UNE OF SAID LOT FOR 300 FEET; NENCE AT RIGHT ANGLES NORTH 75 FEET. % THENCE SOUTH aq,5V2Y EAST TO WESTERLY UNE Of SAO COUNTY .0 ROAD; THENCE SOUTHEASTERLY ALONG SAID WESTERLY UNE TO THE TRUE POINT OF BEGINNING. AFN ALTERATION OF A PORTION OF LOTS I AND 2. BLOCK ALDERWOOD MANOR NO. 9 :, (VOLUM 10. PAGE 0) IN SE11/4, SWI/4, SECTION 10, T.27N., R.4E., W.M. LOVELL-GAVERLAND & ASSOCIATES, INC. 111111400 33RD AVENUE W., SUITE 200 LYNNWOOD. WASHINGTON 98038 42a.776.1501 LOA FILE NO. 4486 SHEET 2 OF 6 -1 0 P-� EX. J:.dR-A SS DISK W1 -P 1�&NG.:'N ED 'f.COR -1 S 89'�2'17- E �P)' S 89-2400 f.C1204) — S asplor E _. 13111-60'M0204) ... ...... EX*. 4'W 4�ldt;;CRETE I MON UANI TIM TH ' -5/' ORA, NTH 11 -CMIN I VISITED -11 _03...% EX. 3 - BRASS DISK "TH 'X* IN CASING 'ASITED ; 4-11 _ 03 2 I . . ...... (P) IL Ci a. C, .4 .7 4 . .... . I ; - P- 4 % \9,2 N SM'38t a - a V . I 213."M) zi3.aV(TP4) A 4 60. TPA T m m'r P A R KI A DEL 0 1%1 v 0 L 21, ..p G. 70) --lD . : . 4 4 .'t;. 4- X 4- Coy'�iiTE MONUMENT V?W 1-5/8* 7M BRASS DISR WITH EX, 4C:LX:4T NCNCR MONU T. �FIE BRASS CAP NTH . X' IN CA NG VISITED ; 4-11-03 MADRONA COVE SECTION 19, T.27N., R.41E., W.M. CITY OF EDMONDS SNOHOMISH COUNTY, WASHINGTON r. (u) (� (I 2D4) b-60'53'54' b-69'58'00' R-575.01' R-573.69' L-701 43' L-700.56' T-�':sr T-401.45' "011 A 6 11, 0 C Y, I V 0 , 'A 0., t A PARCEL 9 "ES 'ME ESTABLISHED PARILLM T. THE CAST LINE OF TOMMY PARK ADD. _E� 891t�27- W L N— No. 4 AT DISTANCE 4,35' FROM 24 - - MONU14E T AT THE MORN END 250.00�(600ESC) OF PIONEER WAY AS PRESCRIBED By PLAT OF SEAWOOD. PARCEL A 9 ��LLJNE.5-C'D !!�- NTTH N 59'55'27* W 11 (M.1204) 6,69'32*ocr ui R-573. :D L.....121* I z 2 ' T.398.231 OD SOUTH QUARTER OF SECTION 19 EX. 4' X 4' CONCRETE MONUMENT NTH 2* BRASS CAP VATH 'X7 IN C SING MSITED : —1-03 4"(P4 L-23.54� '1<1W, 212th STREET S.W. ji U) Q 4 EX. 4' X 4' CONCRETE I T'— R-545.01 5 MONU ENT WTH 2" BRASS CAP WITH 'X' N M a. IN CA MSITED`�, 4-11-03 'C' c Cli EX. 3' BRASS DISK 'X' NTH IN CASL40 VISITED : 4-11-03 LIN T CLAIE PE CAR M DEED RECORDED UNDER 0 PARCEL C 0 - r.OUNDARl A.F. NO. 200402100231 SEE DETAIL BELOW 13 N W*E s .. \ SCALE : I'-IOV "4,,� N MV3 E-287;0(4�EOVERALL S ST_ 251 A) PARCEL 0 0' 20'40'60'50'IW 150' 20WOr ".. ..' 4j�" G 4-%J!S; _71 I �,OO D RCEL F PARCEL E EAST 295.11' \41 "0 V,- ") t 'o SEE ABOVE RIGHT FOR CONTINUATION % \k '�Q .--CEGENR.'*' 41 (P) -.lf?ERS TO COURSE OR DISTANCE MOM PLAT OF 11 AUDERWOOD MANOR NO. 9 (VOL. 10. P$A� 4.35'- o;lf 61 Ns 0,19,10-W 64) REFERS TO COURSE OR DISTANCE. mbu sNowomisH 4' R 4* CONCRETE .83- COUNTY ROAD SURVEY NO. i2p4wbATED IULY,.1?3O EX, X MONUMENT NTH 1 -5/0' 41.92' is 136.23' (V4) REFERS TO COURSE OR DISTANCE FROM PLAT OP TOMMY BRASS DISK WITH 'X* IN CA NG4_11_0 leAl N 89'56'23* E-217.04' OW ALL EAST-2113.22' (SEA) PARK ADO. NO. 4 QVW- 27. PG. 70) VISITED 3 / (SEA) - REFERS TO CqUIM OR DISTA POIt PLAT OF / BOUNDARY LINE SEAWO�.�V� 47, PGS. PER OUIT CLAIM DEED REC DED UNDER (DESC) - REFERS TO COURSE OR MOM jfOAL DESCROMON A.,. NO. 2..", (M) - OASURED OR �ALCC�ATED COURSE (jDISTANCE FA THIS PLAT BASIS OF BEARINGS THE CENTERUNE OF BOWDOIN WAY PER PLAT OF ALDERWOOD MANOR NO. 9 AS MONUMENTED STATISTICS EOUIPMENT; UETZ SET 4 ELECTRONIC TOTAL STATION METHOD: FIELD TRAVERSE ACCURACY. CONFORMS TO WAG 332-130-090 MONUMENTS VISITED: APRIL 11, 2003 AFN 0700 31 ALTERATION OF A PORTION OF LOTS I AND 2, BLOCK 6. ALDERWOOD MANOR NO. 0 (VOLUME 10. PAGE 0) IN SEI/4, SWI/4, SECTION 10, T.27N., R.4E., W.M. LOVELL-SAUERLAND & ASSOCIATES, INC. 19400 33RD AVENUE W.. SUITE 200 LYNNWOOD, WASHINGTON 98038 425.776.1591 LSA FILE NO. 448e SHEET 3 OF 5 0 0 MADRONA COVE SECTION 19, T.27N., F1.4E., W.M. LEGEND CITY OF EDMONDS EX..011014 PIN WITH 0. SET 15' X 2C PON PIN WITH PLAS71C CAP NO'D 221169 /-.VkP NO'D 9891 SNOHOMISH COUNTY, WASHINGTON 0 . SET 4"X 4' CONCRETE MONUMENT WITH 1-5/5' BRASS DISK STAMPED *22969' WITH AN '.' IN CASINO AS I IV ad CON51RUCTION 15 COMPLETED A, 45'. ('Ir Car . COMMON DRIVEWAY CASEMENT COESDE - CITY 01 EDMONDS STORM DRAINAGE EASEMENT L �71�.ix. I T. N COE - CITY OF EDMONDS SANITARY SEWER EASEMENT NAIL EDGE Of CON GOIEISSDI .1 OF EDMONDS SANITARY AND/OR STORM '0' Aff, W*E T IN ILS 5.01, . .. ... 34' SEWER EASEMENT 4 PRDE . PRIVATE DRAINAGE EASEMENT A-39:45-4- COESDE 'VO"t1�'C"L 137.22' TC! 66 LK EASEMENT A!4NO. 2063M %,,5VAV - E (DESC) 235 54. V�� P - PUBLIC SIDEWA N 7V'156 c E C., % SCALE :31*-5V PRMVJE - PRIVATE WALK AT EASEMENT FOR MADRONA COVE TRACT 995 s 1�175622!56* E Lni: . . ........ HOME ERS ASSOCIATION . . . . 3, L�A , , . N \ X\ HOME C."'VAL / 'G IE_ - .:� ..... ­". -t SSE . PRIVATE SANITARY SEWER EASEMENT " * . 3sF- 6 CpE 8 '.. 0! 10`20'30'40*50' 75, tt, ,, �4�; y POE - PUBLJC DRAINAGE EASEMENT OPEN SPACE t .0 R-190 ILL 0 -N52.i3 N5215*58*W T-26.9 22.52' B�CKK sd BSBL BUILDING SETBACK LINE (SEE RESTIRCTIONS. ITEM 4. :L b.43*5a*59* 9 6-30-09*25' 1 1 18.5- COE%e... L-13.112* PAGE 2) A.F. 1,0.21)707.1. 7,028 SF By 4.Z., Ul ci (P) REFERS TO COURSE OR D! TAHOE FROM PLAT OF a ALDERWOOD MANOR NO. 9 (VOL 10. Pr. 6) CITY OF EDMONDS (1204) RCFERS TO COURSE OR DISTANCE FROM SNONOMISH z TWACT 9%* 17.48' -,o -;5.554 s.r. I I :-,k T SLOPE ­.E.l A.I. J COUNTY ROAD SURVEY NO. 12D4 DATED JULY. 19M CRITICAL -aEq 1. a NO. 2036737, 2036738 OPEN SPACE I "Qx: It 4 0 AND 2036739 .&- (TP4) REFERS TO COURSE OR DISTANCE FROM PLAT OF TOMMY t 3,548 S.I. 89'56'2Y' p, '0' t; v 0 -,10' U11LITY--_.r 5 PARK ADD. NO. 4 (VOL 27. PG. 70) 1 ...... 79.7k .... �4' IQ * !.I ! i I L-46.2Y 76 S.F. &.5811,3r &F, (TYPICAL), (SEA) REFERS TO COURSE OR DISTANCE FROM PLAT OF SEAWOOD (VOL 47, PGS. 5-6) -ST ....... ` 10' POE .......... t'I' j ...... 80.52 (DESC) REFERS TO COURSE OR DISTANCE FROM LEGAL 4L -10' PRDE 149� ......... 97.35' - L.15.60' LOTS ia-22% &.11-51-44 DESCRIPTION TV_VFFDE_FC5f 1 '55-04-1 OTS 13 - 22 r- 1% 4;� . ? , 1.4012 A. NO' b . ' 4 L 0 T 4 ji-roy 20 1'. FOR COTS ....... 1AST.. L-21.3" 27. 3 .5 vrod� 18 1"2 ............ 61 ............. EAST ............. e 4.02,1 �.F. NOTE I, CR-410.00' 2L2 0 arw'2a' E, �,J ....... .... 116.70- ALIL LOT CORNERS WILL BE MARRED WITH IS'X 24' L-0.79' ........ .... I. V) R.N PINS .11. PLASTIC CAPS NO-D. 22969. 3 S. Uj" �29;2'51- *.'e 2, 79 S.F. 6,,t52 S.F. T-20 55' 3 TR. 996' AS CONSTRUCTION IS COMPLETED ­111 .% 9 EA ENT UJ F LANDSCAPE 19 - ) .81 6,2 - g \t; FOIR ADDITIONAL EASEMENT DETAILS SEE SHEET 5 I OR (TYPICAL) :6 a TER C�' or FOR a COTS 8_ _J E ....... EAST—- ..... 134.48 22 L �.� .. ... I CL .......... . EAST--- .97 ... .... ........ ....... log TRACT 998 .. ....... . SBLCTYPICAL)­� . ;5 16,957 S.F. 30 TR.ACT 9f6.DATA A '.1 _T 5.5500 S.F. . I 7�/� i . I .. OPEN SPACE/ C11 2 -4 REC. AjkEW' % % 6,420 S.F. F. 4.869 S F. Ii 9 1 N 0516 7. C 114-31.�2"�-4 0 7 3 a ... Ing, A 2 :1. 11.27 4, aG.a, -E.Sf 10 N 59'56'23' E-2157.D4' OVERAiL c E -293.22*:(SEA) AST 2i.5 BOUNDARY LINE 'd'lp % EA ST 62. PER QUIT CLAIM DEED % "I tv 11: DED UNDER 70.25' - \ �q, RO .1; .2 "1% A.F.014 . 200402100231 T EX. JR& PIN WITH 'D �AP NO�D 17 ...... L .oT .oT oT L 0 1 fR-68,50' t 15 d S. "), 1. .. . .0 N as.- W -3. 59AWOOD: ".p '! ' - (VOL 47. PG 17 4.7 TRACT 999 77 SF 1. 3 S.F.: . .............. 7*454 S.F % 16 OPEN SPACEL&, RECREATION AREA\ 1b lb 1b. % __1 Be- jzb�+ 1-60,00-f --- 2S.45!--___t T 0 [AiT - ZT6.117 - 6 FT. WOW ',.a TY OF EOMON S SANITARY FENCE 0,3 .1 SeWE .4 R EASEMENT A.F. NO. 2070845 Ib A 20701148 CITY OF EDMONDS SA.1 ARY + 0 SEKR EASEMENT A.F. NO. 2070632 A v7QQfQ3/ZSg FN Mo N T c L A I W­-C 0 N DO M I N I U M ALTERATION OF A PORTION OF LOTS I AND 2 0.", %tD 10 0 8 0 0 2 BLOCK 5, ALDERWOOD MANOR NO. 9 A.F. N . 200 (VOLUME 10, PAGE 0) STATISTICS BASIS OF BEARINGS EOUIPMENT: UETZ SET A ELECTRONIC TOTAL STATION TH CENTERLINE OF BOWDOIN WAY PER IN SEI/4, SWI/4, SECTION 19, T.27N., R.4E., W.M. PLAT OF ALD WOOD MANOR NO. 9 AS I .. % METHOD! FIELD TRAVERSE UONUMENTEO`R LOVELL-SAUERLAND & ASSOCIATES, INC. ACCURACY. CONFORMS TO WAG 332-130-090 0 19400 33RD AVENUE W., SUITE 200 MONUMENTS VSITED: APRIL 11. 2003 LYNNWOOD, WASHINGTON 9a038 425.775.1G91 % LSA FILE NO. 4486 SHEET 4 OF 5 0 A N MADRONA COVE LEqEAD 18' X W IRM-O"N' T� PLASTIC CAP .0`0 22969 SECTION 19, T.27N., R.4E., W.M. w*E CITY OF EDMONDS SNOHOMISH COUNTY, WASHINGTON SCALE: 45' 60, ,,,�'EX ' IRON PIN WTH CAP NO'D 17672 N ai-41- EX IRON PIN MTN CAP.NO'D 4561 'C '" 0" IRON Pl W 'MTN CAP Ii.-D 1.1 'v J'. Zip E IRON PIN MTN CAP NO'D 17672 S"id21*31* E 156,71' AND S 23M'29* W 0.50' MOM MW PROPERTY CORNER 6 FT. WOOD FE NCE 0 4 FT,'C.. 2 LINK CN GNO.FfNCE 0.3' NE OF LINE cl� -.,AIN OF CHAIN P % ��j O.,'� NENCE ON LINE t W OF CORNER s 7 ANGLE PONT OF FENCE OX E. LIq 111EM"EN 0" % 10 RIVATE (Tw'CAL.) 1. .. DR INAGE 7eF2"SG'*S'-- EASEMENT L -�R . ACT qq� '9.2; 4, FOR LOTS 5-9 ICY PRIVATE % DRAINAGE 0 FASE ENT ..'? % OR LOTS 6-9 8 7 L_ ' ' 9 TRACT 997 AM, ;s I 'Is 10' BuILaNG C.'s, .57 SETBACK LINE SLOPE FROM TOP 0 0 4 10' PRIVATE % 1. a l' WALKWAY EAST. .* L EASEMENT EAST EASEMENT TO BENEF' tOTS 6. 7. 8 AND 9 SCALE : 1'-30' 0' 13, 30' I I It vil 9 \8 PRIVATE ­� — EASEMENT M BENEFIT LOTS to. 11 AND 12 10 '%, Q1. \ \ � 'I, s FT. WOOD ------- FENCE 6 2o' Pmc I I * ; I . L-13.!2 . 0 \ 3,%95' — % — — — — — — — — - I _Z:�� 9.8 UTIuTY 6-43U 5 AST L — — --- +-I ------------- 2; 20' %4k % ABOVE FOR to, UTWTy DIE. EASEMENT PRIVATE EASEMENT (TYPICAL) DRAINAGE ...... EASEMENT I D" A IN THIS AREA U R 10 10' PUBLIC EA I F 0 DRAINAGE i LOTS 2 AH? EASEMENT 21 - _J EA I LOTS 111,- 21 — — — — — — — — — — 20 DRAINAGE E�'ZIIBFOR LOTS 10-12 ASE ENT TRACT"098 (TYPICAL) LINE TABLE FOR BSBL LINE LENGTH BEARING 10' UTILITY LI S94 L2 11.51' 4,3-20-11: E L3 N — S ! 4" L4 L5 m3a Lf 1. 7Z 11 705*2526'5449-' WW EASEMENT R::,:UR:S�rL T A F R S 1O.A. -BIL AND, NORTH BOUNDARY BUILDING SETBACK LINE LOT 9 DETAILS EASEMENT x I?Y.PRIVATE WALKWAY EASEMENT, 5 5 W EACH SIDE OF COMMON PROPERTY LINE OF LOTS 9 AND 10 w L) I AFN CL ALTERATION OF A PORTION OF LOTS I AND 2. BLOCK 5, ALDERWOOD MANOR NO. 0 (VOLUME 10, PAGE 8) Ell IN SEI/4, SWI/4, SECTION 19, T.27N., R.4E.. W.M. LOVELL-SAUERLAND & ASSOCIATES, INC. 19400 33RD AVENUE W., SUITE 200 LYNNWOOD, WASHINGTON 98036 425.775.1501 LOA FILE NO. 4486 SHEET 6 OF 6 -C . 1 sc)c3 E CITY OF EDMONDS 121 5TH AVENUE NORTH - Edmonds, WA 98020 - (425) 771-0220 - FAX (425) 771-0221 HEARING EXAMINER FINDINGS, CONCLUSIONS AND DECISION OF THE HEARING EXAMINER CITY OF EDMONDS GARY HAAKENSON Pit- MAYOR cz;t , :'." De'r NOW 3 '14 APPLICANT: Phoenix Development Inc. (See Exhibit 1, Attachment 2) CASE NO.: V-03-104 LOCATION: The variance is for the construction of a house on lot 18 of the Madrona Cove Subdivision (PRD-2002-171 / P-2002-172) (See Exhibit 1, Attachments I and 2) APPLICATION: The Edmonds Comm" unity Development Code 16.20.03 0 identifies the maximum height for a residence within the RS-8 zone as 25 feet. ECDC 21.40.030 requires that height be measured from the average grade as measured from undisturbed soil. The original request was to exceed this by 10.07' in order to construct a house with a maximum height of 35.07' above average original grade (see Exhibit 1, Attachments 3-5). The latest revised request is to exceed the height requirement by 0.7' (see Exhibit 24). REVIEW PROCESS: Hearing Examiner conducts a public hearing and makes the final decision. MAJOR ISSUES: a. Compliance with Edmonds Community Development Code (ECDC) Section 16.20.030 SINGLE-FAMILY RESIDENTIAL - Site Development Standards. b. Compliance with ECDC Chapter 20.85 VARIANCES. SUMMARY OF RECOMMENDATION AND DECISION: Staff Recommendation: Approve Hearing Examiner Decision: Approve Incorporated August 11, 1890 Sister City - Hekinan, Japan Oaring Examiner Decision Case No. V-03-104 Page 2 PUBLIC HEARING: After reviewing the official file, which included the Planning Division Staff Advisory Report, and after visiting the site, the Hearing Examiner conducted a joint public hearing on the subject request and fifteen other variance requests on the approved Madrona Cove PRD. The hearing on the application was opened at 9:30 a.m., October 2, 2003, in the City Hall, Edmonds, Washington, and at the end of that hearing, it was determined that the tape recorder was not working properly, so there was no official record of the hearing. The hearing was therefore continued to 7:00 p.m. October 15, 2003. The hearing was reopened at 7:15 p.m. on October 15, 2003, in the City Hall, but it was announced at the beginning of the hearing that the applicant had requested that the hearing be continued to October 29, 2003. The Examiner allowed those present to offer comments and at 7:47 p.m. continued the hearing to 7:00 p.m., October 29, 2003. The hearing was reopened at 7: 10 p.m., October 29, 2003 in the City Council Chambers and at 9:43 p.m., the hearing was continued to 7:00 p.m. November 19, 2003. The hearing was reopened at 7:08 p.m., November 19, 2003 in the City Council Chambers and was closed at 8:35 p.m. By the end of the November 19, 2003 hearing, the applicant had withdrawn nine of the variance requests and had modified the other seven. At the request of the Examiner, the Applicant agreed to allow additional time for the preparation of the Examiner's reports. Participants at the public hearing and the exhibits offered and entered are listed in this report. A verbatim recording of the hearing is available in the Planning Division. HEARING COMMENTS: The following persons offered comments at the public hearing. From the City: Steve Bullock, Senior Planner Star Campbell, Planner From the Applicant: Jim Egge Bob Vick From the Community: Matt Douglas Don Kreiman Eric Dickerson Troy Stafford John McLain David Moore Rich Demeroutis Mary Jo Sakoi Ray Martin Finis Tupper Roger Hertrich CORRESPONDENCE: The following members of the general public submitted correspondence and/or other materials into the file. Pauline & Charles DeWarne, Exhibit 2 0 Desmond Call, Exhibit 3 Sandra Nichols, Exhibit 4 Matthew & Tracie Douglas, Exhibits 5, 18, & 19 Dr. Ronald Manger, Exhibit 6 Marilyn & Ross Conley, Exhibit 7 David Thorpe & Laura Mason, Exhibit 8 Karen Biermanski, Exhibit 9 Don Kreiman, Exhibits 20A, 20B & 20C SUMMARY OF CONCERNS & RESPONSES: learing Examiner Decision Case No. V-03-104 Page 3 Following is a summary of concerns expressed by members of the general public and responses from the Applicant and from Staff. The following summary addresses all of the variances requested because a joint hearing was held to consider all of the requested variances. Concerns: • The additional heights would spoil the looks of the neighborhood and would set a precedent for other builders in Edmonds. • Since Madrona Cove is an approved PRD, the developer is precluded from asking for a height variance according to ECDC 20.35. • Approval of the Madrona Cove PRD was a legislative decision by the Edmonds City Council and this request should be sent back to the City Council for final decision. • It is difficult to envision how a developer could not have been aware of the need for variances at the time the PRD case was presented to the City Council. The applicant did not ask for a variance during the PRD process, yet knew variances would be needed before the PRD was approved. The PRD may not have been approved if the City Council knew this many variances would be necessary. The existing houses in the area are built to code and residents in the area expect the new development to fit in with the existing houses. The approval of the variances and resulting increase of height and house size will make Madrona Cove inconsistent with the surrounding community. • It would be a grant of special privilege if this developer were granted variances when one of the existing neighbors was denied a one -foot height variance. • The topography of Madrona Cove is the same if not less severe that the topography found in the rest of the neighborhood. The existing homes had to be built with retaining walls and dug down to meet the height requirements. The new development should have to meet the same criteria that the existing neighborhood had to meet. Profit or extra expense to develop a property may not be used to gain approval of a variance. 0 No other house in the area is over 25'. in height. These homes will be higher than that. learing Examiner Decision Case No. V-03-104 Page 4 9 The height envisioned by the applicant is out of character with normal single-family development envisioned by the Comprehensive Plan. * Approval of the variance will not be consistent with the purpose of the zoning and the zone district in which the property is located. 0 Views of properties in the vicinity would be harmed. 0 The duplex on Pioneer Way, which was referred to by the applicant, is not near this development and should not be referred to further. * There should only be four houses built on Pioneer Way instead of five. Then all of the garages could be on grade. 0 Adjustments could be made to the roof pitches and then no variances would be necessary. 0 The developer would save thousands of dollars if he gets the variances. 0 There should not be any need for variances in a PRD. * Only lot #6 looks like it needs a variance. 0 Three different proposals have been submitted for the variance requests. The developer has made a good faith effort by the final revision, but the variances would still set a precedent. 0 1 t o I 1/2story buildings may be appropriate on this property. 0 Why not dig a little deeper or modify the roofs a little more? Responses from the Applicant: • The applicant could have done a straight plat or attached homes, but chose to do a detached project with preservation of significant open space. • Trees will be left in the native growth protection area near Main and the other open space areas will be left undisturbed, except where the utility pipes are to be installed. A future trail will be installed over that. • At the beginning of the PRD process conceptual plans were submitted. Grading plans were then prepared and have been reviewed by staff. At this stage of the process each lot is looked at. • The applicant has tried to preserve the landform. and has tried to eliminate the need for as many variance requests as possible. • The variance requests for Lots 1, 3, 4, 8, 15, 16, 19, 20, and 21 have been withdrawn. • The houses on Lots 2 & 5 have lowered building pads and lower roof pitches. • The house on Lot 6 is complicated by how the average grade is measured. The old driveway cut is shown on the plans and is part of the calculation. The house is to be kept up near the end of the cul-de-sac. 0 0 Lot 7 has a lower roof pitch. * Lot 9 is similar to Lot 6. &nng Examiner Decision Case No. V-03-104 Page 5 • The house on Lot 18 is moved back on the lot and the roof pitch is reduced. • The house on Lot 22 is cut into the hill. • No other variances approved in the City were used as a precedent in this request. • Rockeries on Lots 6 & 9 would impact the neighbors to the north more than what is being proposed. • If the building pads are lowered any further, the lots will not drain properly and water will pond at the foundations. Response by Staff: After the PRD process is complete then someone can request a variance on a case -by -case basis. There is nothing in the code that says you can't request a variance after a PRD is approved. 0 The old driveway on Lot 6 is not being used as basis for variance approval. Staff believes the requests comply with the variance criteria and that they should be approved. GENERALBACKGROUND: In May of 2003, the City Council approved the 22-lot Formal Plat and Planned Residential Development known as Madrona Cove. This approval established areas of the site to be protected as native growth areas, public open space areas, connection of and with City bikeway and walkway elements, a specific lot layout and a specific look for the homes to be constructed in this development. Five different house plans were approved to be used throughout the site. The applicant also submitted a preliminary grading plan during the Plat and PRD process that was reviewed and generally approved for compliance with the City's policies related to grading as stated in the Comprehensive Plan. However it was not a final approval of the grading plan or plat construction documents. As the applicant started to work on the final grading and construction documents it became apparent to them that some of the house designs approved through the PRD process were going to require variances for height. This was because of the amount of grading required to bring in the road and provide reasonable access to the individual lots and the design of the individual house plans. At that point, the applicant sat down with staff to discuss the possibilities. Staff's direction to them was to first design the grade of the road to follow the existing contour of the land as closely as possible. Second, andjust as importantly, they would have to make sure that road grade would require minimal grading of the individual lots to provide reasonable access to those lots from the road for the approved house designs. If the applicant could demonstrate these things, they might be able to meet the variance criteria as stated in ECDC 20.85. Oaring Examiner Decision Case No. V-03-104 Page 6 The applicant took this direction and continued to work on the grading plan for the project as well as selecting the specific house plan for each lot that would most closely comply with the City's regulations and policies for height and minimizing grading. After working through their plans a number of times, the applicant has confirmed with staff that the proposed road grading complies with the Comprehensive Plan policies encouraging retention of existing topography and minimizing cut and fill excavation work. Staff also confirmed that the grading proposed for the individual lots appears to be the minimum amount of grading needed for each lot to have a slightly elevated building pad in relation to the road. The resultant grading will resolve any drainage and access issues on the site. With this understanding, the applicant first requested height variances for 16 of the lots. Lots 1-9 are located on the east and north sides of the upper access road. The addition of fill on those lots to provide reasonable vehicular access from the proposed road along with the house designs approved by the Hearing Examiner and the City Council drove the initial need for the variance request on these lots. Lots 15, 16 and 18-22 of the approved plat and PRD have the most significant grades of all the lots in the development. In an effort to minimize the excavation needed on these lots the applicant has selected a house design that has a smaller footprint and steps up the hillside. However, the three-story plan with the approved elevation design necessitates the variance request. During the hearing process, a number of neighbors expressed concerns and opposition to the multiple variance requests in the proposed development. As a result, the applicant has reworked a number of the house plans and has withdrawn nine of the variance requests and has substantially reduced the variance amounts on the remaining seven -variance requests. Following is a review of the variance request for Lot 18. Specific proposal for V-2003-104, Lot 18-height variance request of 0.7': Lot 18 is the first lot on the right as you enter the lower portion of the development from Pioneer Way. The grading of the new road along with the specific house plan selected for this site has resulted in a variance request of 0.7 feet. FINDINGS OF FACT AND CONCLUSIONS: A. SITE DESCRIPTION 1. Site Development And Zoning: a) Facts: (1) Size: The lot size is approximately 5,200 square feet. See Exhibit 1, Attachment 2. (2) Land Use: The subject property is part of a 22 lot PRD that has received preliminary approval. The applicants are currently in the process of creating the final plans for the construction of the plat improvements including grading and installation of the road and utilities on the site. earing Examiner Decision Case No. V-03-104 Page 7 (3) Zonin : The subject property is located within the planned residential development of Madrona Cove (PRD-2002-171 / P-2002-172). The underlying zone is RS-8. See Exhibit 1, Attachments I and 2. (4) Terrain: The lot slopes up substantially from the front of the lot to the rear (west to east) with the steepest grade near the rear of the lot. Refer to Exhibit 1, Attachment 2 for the original topography and Exhibit 1, Attachment 3 for the grading plan that is currently under review in association the City's review of the final plat. 2. Neighboring Development And Zoning: a) Fact: The property to the west across Pioneer Way and the property directly to the east are within the Madrona Cove PRD and are designated open spaces. The property to the north is also within the Madrona Cove PRD and will ultimately be developed with a single-family residence. The property to the south is zoned Single -Family (RS- 8) and is developed with a single-family residence. Refer to Exhibit 1, Attachment 1). b) Conclusion:. The proposed development of single-family residences is consistent with the surrounding zoning and development. B. COMPLIANCE WITH THE COMPREHENSIVE PLAN The Comprehensive Plan has the following stated goals and policies for Residential Development and development within areas of sensitive soils and topography which appear to apply to this project. Residential Development B. Goal. High quality residential development, which is appropriate to the diverse lifestyle of Edmonds residents, should be maintained and promoted. The options available to the City to influence the quality of housing for all citizens should be approached realistically in -balancing economic and aesthetic consideration, in accordance with the following policies: B. 1. Encourage those building custom homes to design and construct homes with architectural lines, which enable them to harmonize with the surroundings, adding to the community identity and desirability. B-3 Minimize encroachment on view of existing homes by new construction or additions to existing structures. B.4. Support retention and rehabilitation of older housing within Edmonds whenever it is economically feasible. B.5. Protect residential areas from incompatible land uses through the careful control of other types of development and expansion based upon the following principles: Oaring Examiner Decision Case No. V-03-104 Page 8 B.5.c Sable property values must not be threatened by view, traffic or land use encroachments. B.5.d. Private property must be protected from adverse environmental impacts of development including noise, drainage, traffic, slides, etc. BA Require that new residential development be compatible with the natural constraints of slopes, soils, geology, vegetation and drainage. C. Goal. A broad range of housing types and densities should be encouraged in order that a choice of housing will be available to all Edmonds residents, in accordance with the following policies: C. I Planned Residential Development. Consider planned residential development solutions for residential subdivisions. C. La Consider single-family homes in a PRD configuration where significant benefits for owner and area can be demonstrated (trees, view, open space, etc.). Soils and Topography B. Goal. Future development in areas of steep slope and potentially hazardous soil conditions should be based on site development which preserves the natural site characteristics in accordance with the following policies: B.2. Streets and access ways should be designed to conform to the natural topography reduce runoff and minimize grading of the hillside. C. Goal. Development on steep slopes or hazardous soil conditions should preserve the natural features of the site, in accordance with the following policies: C. 1. Grading and Filling. C.I.a. Grading, filling, and tree cutting shall be restricted to building pads, driveways, access ways and other impervious surfaces. C.I.b. Grading shall not jeopardize the stability of any slope, or of an adjacent property- C. I.c. Only minimal amounts of cut and fill on hillsides exceeding 15% slope should be permitted so that the natural topography can be preserved. Fill shall not be used to create a yard on steeply sloped property. C. I.d. Filt-and excavated dirt shall not be pushed down the slope. C-2. Building Construction. C.2.a. Buildings on slopes of 15% or greater shall be designed to cause minimum disruption to the natural topography. Oaring Examiner Decision Case No. V-03-104 Page 9 C.2.a. Retaining walls are discouraged on steep slopes. If they are used they should be small and should not support construction of improvements, which do not conform to the topography. C.2.a. Water detention devices shall be used to maintain the velocity of runoff at predevelopment levels. C.3. Erosion Control. C.3.a. Temporary measures shall be taken to reduce erosion during construction. C.3.b. Natural vegetation should be preserved wherever possible to reduce erosion and stabilize slopes, particularly on the downhill property line. C.3.c. Slopes should be stabilized with deep-rooted vegetation and mulch, or other materials to prevent erosion and siltation of drainage ways. 1. Comprehensive Plan Analysis a) Facts and Conclusions: (1) Staff worked with the applicant to ensure that the roadway was designed to conform to the existing natural topography. (2) As established with the approval of the PRD, the homes proposed to be built in the Madrona Cove PRD demonstrate compliance with the Comprehensive Plan policies as they relate to Residential Development and Soils and Topography. (3) The proposed Variance will not allow development that encroaches onto any adjacent property's view or privacy. (4) The proposed Variance complies with the policies of the Comprehensive Plan as they relate to Residential Development and Soils and Topography. C. STATE ENVIRONMENTAL POLICY ACT (SEPA) 1. Fact: The proposed variance does not require SEPA review. 2. Conclusion: The applicant and the City have complied with SEPA regulations. D. EDMONDS COMMUNITY DEVELOPMENT CODE (ECDC) COMPLIANCE 1. Zoning Standards a) Facts: (1) Though the site was developed as part of a PRD, the height limit for the underlying zone applies. The site development standards established by ECDC 16.20.030 establishes a maximum height of 25 feet from the average original grade. Refer to the definition of height in ECDC 21.40.030. (2) The applicant may request a variance from the maximum 25 feet via the variance process as described in ECDC 20.85. earing Examiner Decision Case No. V-03-104 Page 10 b) Conclusion: The applicant is requesting a height variance of 0.7 foot as described in Exhibit 24. 2. Compliance with the Variance Criteria ECDC Chapter 20.85 (Variances) states an applicant may request a variance from the standards of this Chapter pursuant to the procedures set forth in ECDC Chapter 20.85. Chapter 20.85 of the ECDC also sets forth the mechanism whereby a provision of the Code may be varied on a case -by -case basis if the application demonstrates compliance with stated criteria. a) Facts: (1) ECDC Section 20.85.010 establishes the decisional criteria with which a variance request must comply in order to be granted by the Hearing Examiner. These criteria include: a special circumstance must exist; no special privilege is granted; the proposal is consistent with the Comprehensive Plan and the Zoning Code; the proposal will not be detrimental and is the minimum necessary. (2) The applicant has addressed each of these criteria in Exhibit 24, Attachment A. A site plan and an elevation view have been included as Exhibit 24, Attachments B and C. Height calculations show the average existing grade, the 25' maximum height limit from original grade, and the actual height of the proposed house. (3) The PRD approval authorizes the use of five different home designs for the development. Specific plans were not required to be used on specific lots. (4) In an effort to make sure the variance request was the minimum necessary, the applicant has selected a floor plan from the approved plans that minimizes the request as well as addresses the specific needs of each property for vehicular and pedestrian access. (5) The selected house design for this lot, reviewed and approved through the review of a PRD, is a "garage under" design that has two floors in addition to a below grade garage. This house style has a smaller footprint than the other houses approved for Madrona Cove. The smaller footprint means that less grading is necessary in placing the house on the lot. In order to provide enough square footage in the home, though, the house needs to be taller. (6) The applicant states that, as measured from the building pad to the top of the house, the total height of the house will be 30.5'. Refer to the elevation drawing (see Exhibit 24, Attachment 5). As measured from average existing grade, the height of the proposed house is 26.75', which requires a 1.75' variance. (7) The relationship of the finished floor elevations of the house to the finished grade elevations is detailed on the elevation view (Exhibit 24, Attachment 5). The level of the entrance into the garage from the front of the house is significantly lower than the finished grade level at the rear of the house, which is roughly equivalent to the floor level of the second story of the home. 0 earing Examiner Decision Case No. V-03-104 Page I I (8) Another way to explain this is that it is a house that has direct, at grade access to the garage from the front and direct, at grade access to the second level from the rear, which is the main living floor. This design aspect, which follows the existing topography, also helps to minimize grading on the lot. (9) Lot 18 backs up to a steep hillside with a variety of mature vegetation that has been designated as open space. The lot slopes up substantially from the front of the lot to the rear (west to east) with the steepest grade near the rear of the lot. . b) Conclusions: Examiner's Responses to the Variance Criteria (1) Special Circumstances The Madrona Cove PRD site was developed in response to it's varied topography and mature vegetation. The layout of the lots was created so that the lots are on the flattest portions of the site and significant portions of the site can be retained with existing mature vegetation. Existing grade on the subject lot rises abruptly from the back of the- driveway at an average grade of 18% across the building pad envelope. This is one of five "valley" lots at the end of Pioneer Way. The back of the lot is a transition area from a critical area steep slope, which is being preserved as permanent open space / NGPA within the approved PRD. In order for the home to fit this unique topography, the lot must be either substantially cut at the extreme rear with a high rockery at the rear lot line, or alternatively the home will be "stair -step" graded into the hillside. The latter method will have the least amount of grading on the rear portion of the lot and the adjacent steep slope area. (2) Special Privilege The variance will allow for the construction of a residence that is consistent with the house designs approved through the PRD process. These approve designs are consistent with the Single Family Design Criteria found in ECDC 20.35, which ensure that homes consistent with the aesthetic values of this community and neighborhood are built. No additional views or other benefits are being permitted by the approval of this height variance. (3) Zoning Code The zoning code allows for single-family residential development. The proposed residence is consistent with single-family development. In addition, the variance will allow a house that is consistent with the design of the houses reviewed and approved. through the Madrona Cove PRD process. (4) Comprehensive Plan See section B of this report for how the proposed variance complies with the goals and policies of the Comprehensive Plan. Wing Examiner Decision Case No. V-03-104 Page 12 (5) Not Detrimental No views will be blocked or privacy invaded from the proposed development onto existing development by the approval of the proposed height variance. The proposed variance is not detrimental or injurious to any adjacent property owners. (6) Minimum Required A variance of 0.7' is the minimum necessary to accommodate a three-story (garage underibasement structure) on the subject lot and provide proper drainage. (Refer to Exhibit 24, Attachments A - Q. The applicant has demonstrated that the requested variance is the minimum necessary. DECISION: Based upon the foregoing findings and conclusions, the request for a 0.7' height variance is approved. Entered this 22nd day of December 2003 pursuant to the authority granted the Hearings Examiner under Chapter 20. 100 of the Community Development Code of the City of Edmonds. 70'_' 01 lt_� Ron McConnell, FAI�P Hearing Examiner RECONSIDERATION AND APPEAL: The following is a summary of the deadlines and procedures for filing reconsideration and appeal. Any person wishing to file or respond to a recommendation or appeal should contact the Planning Department for further procedural information. REQUEST FOR RECONSIDERATION: Section 20.100.010.G allows for the Hearing Examiner to reconsider his decision or recommendation if a written request is filed within ten (10) working days of the date of the initial decision by any person who attends the public hearing and signs the attendance register and/or presents testimony or by any person holding an ownership interest in a tract of land which is the subject of such decision or recommendation. The reconsideration request must cite specific references to the findings and/or the criteria contained in the ordinances governing the type of application being reviewed. *aring Examiner Decision Case No. V-03-104 Page 13 APPF.Al.q- Section 20.105.020.A & B describe how appeals of a Hearing Examiner decision or recommendation shall be made. The appeal shall be made in writing, and shall include the decision being appealed along with the name of the project and the date of the decision, the name of the individual or group appealing the decision, their interest in the matter, and reasons why the appellant believes the decision to be wrong. The appeal must be filed with the Community Development Director within ten (10) working days after the date of the decision being appealed. TIME LIMITS FOR RECONSIDERATION AND APPEAL: The time limits for Reconsideration and Appeals run concurrently. If a request for reconsideration is filed before the time limit for filing an appeal has expired, the time clock for filing an appeal is stopped until a decision on the reconsideration request is completed. Once the Hearing Examiner has issued his decision on the reconsideration request, the time clock for filing an appeal continues from the point it was stopped. For example, if a reconsideration request is filed on day 5 of the appeal period, an individual would have 9 more days in which to file an appeal after the Hearing Examiner issues his decision on the reconsideration request. LAPSE OF APPROVAL: Section 20.05.020.0 states 'Unless the owner obtains a building permit, or if no building is required, substantially commences the use allowed within one year from the date of approval, the conditional use permit shall expire and be null and void, unless the owner files an application for an extension of the time before the expiration date.' NOTICE TO COUNTY ASSESSOR: The property owner may as a result of the decision rendered by the Hearing Examiner request a change in the valuation of the property by the Snohomish County Assessors Office. EXHIBITS: The following exhibits were offered and entered into the record. I . Planning Division Advisory Report, dated 9/25/03 2. Letter from Pauline & Charles DeWarne, dated 9/27/03 3. Letter from Desmond Call, dated 9/27/03 4. Letter from Sandra Nichols, dated 9/29/03 5. Email from Matthew & Tracie Douglas, dated 10/1/03 6. Email from Dr. Ronald Manger, dated 10/1/03 7. Email from Marilyn & Ross Conley, dated 10/1/03 8. Letter from David Thorpe & Laura Mason, dated 10/1/03 9. Letter from Karen Biermanski, dated 10/29/03 10. Letter from Phoenix Development, dated 10/20/03, with attached amendment to the variance request Oaring Examiner Decision Case No. V-03-104 11. Staff Memorandum, dated 10/29/03 12. Update Table showing revised variance requests 13. Madrona Cove Comparative Matrix for Variance Requests 14. Four photos of Pioneer Way & Shell Valley Rd. duplexes 15. Grading Plan 16. Site Plan (oversized) 17. Four photos showing existing edge conditions 18. Photo collage of homes on Pioneer Way 19. Letter from Matthew Douglas, dated 10/29/03, with attachment 20A. Arguments re: variance criteria submitted by Don Kreiman 20B. Arguments re: PRD submitted by Don Kreiman 20C. Statements of Fact submitted by Don Kreiman 21. Staff Memorandum, dated 11/14/03 22. Update Table showing 11/13/03 revisions to the variance requests. 23. Site Plan showing withdrawn requests 24. Revised requests for Lots 18 & 22 from Robert McBride, dated 11/14/03 25. Madrona Cove Variance Request Table 26. Elevations of homes to be constructed on Lots 15, 16, & 18 - 22 PARTIES OF RECORD: Robert McBride Phoenix Development Inc. PO Box 3167 Lynnwood, WA 98046 Pauline & Charles DeWarne 20829 Hillcrest P1. Edmonds, WA 98026-6914 Sandra Nichols 2150886 1h Ave. W Edmonds, WA 98026 Dr. Ronald Manger 21026 Pioneer Way Edmonds, WA 98026 David Thorpe &Laura Mason 21127 Shell Valley Road Edmonds, WA 98026 Don Kreiman 2400695 th Place W Edmonds, WA 98020 Dr. and Mrs. Suchert 54012 1h Ave. N. Edmonds, WA 98020 Desmond Call 8732 2091h pl. SW Edmonds, WA 98026-6911 Matthew & Tracie Douglas 21021 Pioneer Way Edmonds, WA 98026 Marilyn & Ross Conley 21116 Pioneer Way Edmonds, WA 98026 Karen Biermanski 8129 Frederick Place Edmonds, WA 98026 Eric Dickerson 21020 Pioneer Way Edmonds, WA 98026 Page 14 Wing Examiner Decision Case No. V-03-104 Page 15 Troy Stafford John McLain 8602 Main St. 21109 Pioneer Edmonds, WA 98026 Edmonds, WA 98026 David Moore Rich Demeroutis 8608 Main St. 921 Pine St. Edmonds, WA 98026 Edmonds, WA 98026 Jim Egge Bob Vick 10807 25" St. SE Phoenix Development, Inc. Everett, WA 98205 PO Box 3167 Lynnwood, WA 98046 Mary Jo Sakoi Ray Martin 21005 Pioneer Way 18704 94'h West Edmonds, WA 98026 Edmonds, WA 980026 Finis Tupper Roger Hertrich 711 Daley 1020 Puget Drive Edmonds, WA 98020 Edmonds, WA 98020 Planning Division City d9EdmQndS.,,, Development Services. Department Planning Division: Phone: 425.771-0220 The Critical Areas Checklist contained on this form is to be filled out by any person preparing a Development Permit Application for the City of Edmonds prior to his/her submittal of the application to the City. 7lie purpose of the Checklist is to enable City staff to determine whether any potential Critical Areas are, or may be, present on the subject property. The information needed to complete the Checklist should be easily available. from observations of the site or data available at City Hall (Critical areas iriv-9I-oQes1-,E WpV,- Qr soil ,.Surveys). I AUG 2 3 2012 A property owner, or his/her authorized representative, must- fill out the checklist.sign and date it, and submit it tcothe City. The City will review the checklist, Make a Pr6c 'site visit and maki'a determina . tion: of the .subsequent steps necessary to complete a development permit a0plication. Please submit a vicinity map, along with the signe4 copy of this form to assist City. staff in finding and locating the specific piece of property described on this form. In addition, the applicant shall include other pertinent information (e.g. site plan, topography map, etc.) or studies in 6onJunction with this -.-Checklist to assistant staff in co mnletin . a , t heir nmli�mi assessment of the she f, t h M. L; L U N 4 " th The undersigned applicant, and his/ber/its heirs, and assigns, in consideration on the processing of the application agrees to release, indemnify, defend and hold the City of Edmonds harmless from any and all damages, including reasonable attorney's fees, arising from any action or infraction based in whole or part upon false, misleading, inaccurate or incomplete information furnished by,the applicant, his/her/its agents or employees. Ilomy signature, I cer*. that ithe information and exhibits herewith submitted are true and correct to the best of my wledge and that I am authorized to file this appli a *on con ;he behalf of the owner as listed below. SIGNATURE OF APPLICANVAGENTLm-ya 1001t VXnatYDATE 11-Hlog Property Owner's Authorization By my signature, I cer* that I have authorized the above ApPlicant/Agent to apply for the subject land use application, and. grant my permission for the public officials and the staff of the City of Edmonds to enter the subject property for the purposes of inspection and posting attendant to this application. Owner/Appfteant:. Name cN be 7 Street Address mA. qWCHU Cityl State . zip Appli.cant-Represen.tative.- aunt Name Street Address city State zip Telephone: filhad ss (optional): J0YtAfia\f)dQQikbQpaa. Email Address (optional): I Lon Critical Areas Checklistdoc/3.191001 PA File No: x- &-itical Areas'!CChec'klisto Site Infomation (soils/topo-graphy/hydrology/ vegetation),. 1. Site Address/ Locati.on: P3,n-1.9- 2. Property Tax Account Number: bI 66 001:��.. 01 09=1� CG Approximate S�i� Size (acres Pr%square fiaet):, 3. 4. Is d-ds site currentIv developed? yes; Ao. If yes, how is site developed?'�--MA di o'l-, ­4 5. Describe the general, site topog raphy. Check all, that apply. Flat- less than 5-feet elevation change over. entire site. Rolling- slopes on site generally less than 15% (a vertical rise of 10-feet over a horizontal distance of 66-feet). Hilly: slopes present on site of more ffm 15% and less am 30% a vertical rise. of 10-feet over a horizontal distance of 33 to 66-feet). Steep: grades of greater thart 30% present on site (a vertical rise of 10-feet over a horizontal distance of less than 33-feet). Other (please describe): 6. Site contains areas of year-round standing water: Approx. Depth: 7. Site contains areasiof seasonai standing water. Approx. Depth: What season(s) of the year?. 8. Site is in the floodway floodplain of a water course. round? 9. Site contains a creek or an area where water flows across. the. grounds surface? Flowsare y Flows are seasonal? Mhat time of year?. 10. Site is primarily: forested X meadow shrubs., X mixed urban landscaped (lawnAmbs etc) 11. Obvious wetland is present on site: W A-F Z 7M ,p _d w: hPIP .4 K C' chfical I#Ote t- I im. Y: ''tL-d. ide"nde"hifid ir .7 _7', Site i�v rt ithih d' q 5 MONA A W . MV M criticaj Areas checklisLdoc/3-19-Mi f City of Edmonds Critical Areas Determination Applicant: Phoenix Development Inc Determination #: CA-02-174. Site Location: 8526 Main St (5.23 acres) Property Tax Acct 3736 005 0 Project Description: I Non -Project Specific Determination: Study Required: During review and inspection of the subject site, it was found that the sife appears to contain and/or is adjacent to a number of critical areas, induding.possible wetland soils and vegetation pursuant to Chapter 20. 1 5B of the Edmonds Community Development Code (ECDC). Based on these findings, prior to submission of any development permit, you will be required satisfy the requirements of ECDC 20.15B by completing the following: Wetland: My site *investigation has shown that the site contains wetlands.oils and vegetation that are possibly part of a stream. Based on the above findings, a Critical Areas Study is required to determine the hydrology of the area and to delineate the approximate boundaries of any stream and/or -wetland and identify its buffers. The required qualified critical areas consultant needed to perform the study shall be a specialist in wetland biology and/or streams with a minimum of two years' field experience with streams in the Pacific Northwest. All critical areas studies shall be Performed as three Party agreements with the city selecting the consultant and the property owner or applicant paying the fees. The qualified critical areas consultant shall perform the following: I i Classify the stream/wetiand. 2. Physically mark the top of the bank of the stream and/or wetland. 3. Map the stream/wetland location. (see ECDC 20.15B). The land surveyor licensed by the State of Washington shall perform the following: 1. Determine the building setback from the buffer (required setback is'15 feet).' 2. Create a map showing the streamotwetland, the buffer and the' building setback. 4V If the results of the Critical Areas Study determine that the lot may not be developed, the applicant may apply for a Reasonable Use Exception and Variance pursuant to ECDC 20.15B.170A and 20-15B.049CA. A / I Name Signature Date L 3736-005-001-01 74 Phoenix Dev. ST "'-115/lF/2'003 GEOTECHNICAL ENGINEERING STUDY PEPPERWOOD RESIDENTIAL DEVELOPMENT 8526 MAIN STREET EDMONDS, WASHINGTON E-10075 May 14, 2002 PREPARED FOR PHOENIX DEVELOPMENT, INC. ya- - 7 Raymond A. Coglas, P.E. Project Manager Earth Consultants, Inc. 1805 - 136th Place Northeast, Suite 201 Bellevue, Washington 98005 (206) 643-3780 Toll Free 1-888-739-6670 "7 ,Z)HR-EET FLE IMPORTANT INFORMATION ABOUT YOUR GEOTECHNICAL ENGINEERING REPORT More construction problernsare caused by site subsur- face conditions than any other factor. As troublesome as subsurface problems can be. their frequency and extent have been lessened considerably in recent years, due in large measure to programs and publications of ASFE/ The Association of Engineering Firms Practicing in the Geosciences. The following suggestions and observations are offered to help you reduce the geotechnical-related delays, cost -overruns and other costly headaches that can occur during a construction project. A GEOTECHNICAL ENGINEERING REPORT IS BASED -ON A UNIOUE SET OF PROJECT -SPECIFIC FACTORS A geotechnical engineering reportis based on a subsur- face exploration plan designed to incorporate a unique set of project -specific factors. These typically include: the general nature of the structure involved, its size and configuration: the location of the structure on the -site and its orientation; physical concomitants such as access roads, parking lots, and underground utilities, and the level of additional risk which the client assumed by virtue of limitations imposed upon 'the exploratory program. To help avoid costly problems, consult the geotechnical engineer to determine how any factors which change subsequent to the date of the report may affect its recommendations. Unless your consulting geotechnical engineer indicates otherwise, your geotechnical engineering report should not be used: • When the nature of the proposed structure is changed, for example, if an office building will be erected instead of a parking garage. of if a refriger- ated warehouse will be built instead of an unre- frigerated one; • When the size or configuration of the proposed structure is altered; • When the location or orientation of the proposed structure is modified; • when there is a change of ownership, or -for application to an adjacent site. Geotechnical engineers cannot accept responsibility for problems which may develop if they a4 not consulted after factors consid- ered in their report's development have changed. MOST GEOTECHNICAL "FINDINGS" ARE PROFESSIONAL ESTIMATES Site exploration identifies actual subsurface conditions only at those points where samples are taken. when they are taken. Data derived through sampling an ' d sub- sequent laboratory testing are extrapolated by geo- technical engineers who then render an opinion about overall subsurface.conditions. -their likely reaction to proposed construction activity, and appropriate founda- tion design. Even under optimal circumstances actual conditions may differ from those infe ' rred to exist, because no geotechnical engineer, no matter how qualified, and no subsurface exploration program, no matter how comprehensive, can reveal what is hidden by earth, rock and time. The actual interface between mate- rials may be far more gradual or abrupt than a report indicates- Actual conditions in areas not sampled may differ from predictions. Nothing can be done to prevent the unanticipated, but steps can be taken to help minimize their impact. For this reason, most experienced owners retain their geotechnical consultants through.the construction stage, to iden- tify variances, conduct additional tests which may be needed, and to recommend solutions to -problems encountered on site. SUBSURFACE CONDITIONS CAN CHANGE Subsurface conditions may be modified by constantly - changing natural forces. Because a geotechnical engi- neering report is based on conditions which existed at the time of subsurface exploration, construction decisions should not be based on a geotechnical engineering report whose adequacy may have been affected by time. Speak with the geo- technical consultancto learn if additional tests are advisable before construction starts. Construction operations at or adjacent to the site and natural events such as floods, earthquakes or ground- water fluctuations may also affect subsurface conditions and, thus, the continuing adequacy of a geotechnical report. The geotechnical engineer should be kept apprised of any such events, and should be consulted to determine if additional tests are necessary GEOTECH N ICA L SERVICES ARE PERFORMED FOR SPECIFIC PURPOSES AND PERSONS Geotechnical engineers' reports are prepared to meet the specific needs of specific individuals. A report pre- pared for a consulting civil engineer may not be ade- quate for a construction contractor, or even some other consulting civil,engineer Unless indicated otherwise, this report was prepared expressly for the client involved and expressly for purposes indicated by the client. Use by any other persons for any purpose, or by the client for a different purpose, may result in problems. No indi- vidual other than the client should apply this report for its intended purpose without first conferring with the geotechnical engineer.. No person should apply this report for any purpose o I ther than that originally contemplated without first conferring with the geotechnical engineer. Earth Consultants Inc. Geofechnical Engineers. Goologists & Environmenial Scientists May 14, 2002 E-10075 Phoenix Development, Inc. P.O. Box 3167 Lynnwood, Washington 98046-0958 0 Attention: Ms. Loree Quade Dear Ms. Quade: W We are pleased to submit our report titled "Geotechnical Engineering Study, Pepperwood, Residential Development, 8526 Main Street, Edmonds, Washington." This study presents the results of our field - exploration and. geotechnical engineering analyses for the proposed residential development. Our scope of services for producing this study were outlined in our proposal PR-10075, dated March 1, 2002. Based on the results of our study, development of the site as planned is feasible from a geotechnical standpoint. Medium dense to very dense glacial till was observed at the test pit locations. Fill and yard waste materials.were observed along the top of the existing slope areas along the upper half of the site at several of the test pit locations. The fill soils were observed to depths of approximately four to five feet. Based on the subsurface conditions observed at the test pit locations, it is our opinion the proposdd single family residences can be supported on conventional spread and continuous footings bearing on the competent glacial till native soils, or on structural fill soils used to modify existing site grades. The existing slope areas throughout the middle of the site appear stable. Due..to.the dense condition of the native ' glacial till soils, the existing slope areas should not be adversely impacted by the proposed construction. In our opinion, the buffer requirements for building construction adjacent to steep slope areas can be reduced. Recommendations for setbacks and other geotechnical recommendations are presented in this geotechnical engineering study. 1805 - 136th Place N.E., Suite 201, Bellevue. Washington 98005 Bellevue (425) 643-3780 FAX (425) 746-0860 Toll Free (888).739-6670 Phoenix Development May 14, 2002 E-1 0075 We appreciate the opportunity to provide our services during the design phase of the project. If you have questions about the content of this geotechnical engineering study, or if we can be of further assistance, please call. Sincerely, EA CONSULTANTS, INC. E Project Manager RAqme Earth consultants, Inc. --1 TABLE OF CONTENTS E-10075 PAGE INTRODUCTION.................................................................................................... 1 General........................................................................................................... 1 ProigctDescription ............................................................................................. 1 SITECONDITIONS ................................................................................................. 2 Surface.................................................................................... I ........................ 2 SteepSlope Evaluation ...................................................................................... 3 Subsurface................................................................................. 3 Groundwater....................................................................................... 4 LaboratoryTesting ............................................................................................ 4 DISCUSSION AND RECOMMENDATIONS ................................................................ 4 General............................................... ............................................................ 4 Site Preparation and General Earthwork .............................................................. 6 SteepSlope Buffer ............................................................................................ 7 Foundations..................................................................................................... 8 Permanent Retaining and Foundation Walls ........................................................... 9 Seismic Desian Considerations ...... ; .................................................................... 10 Slab -on -Grade Floors ........................................................................................ 11 SiteDrainage ......................................................... \ .......................................... 11 Excavationsand Slopes .................................................................................... 1 Utility Trench Backfill ........................................................................................ 12 Rockeries...................................................................................................... 13 PavementAreas ...................................................................................... ) ......... 14 LIMITATIONS...................... I ................................................................................. 14 AdditionalServices ........................................................................................... 15 Earth Consultants, Inc. TABLE OF CONTENTS E-10075 ILLUSTRATIONS Plate 1 Vicinity Map Plate 2 Test Pit Location Plan Plate 3 Typical Footing Subdrain Detail Plate 4 Typical Utility Trench Fill APPENDICES Appendix A Field Exploration Plate Al Legend Plates A2 through Al 2 Test Pit Logs Appendix B Laboratory Test Results Plate 131 Grain Size Analyses Earth Consultants, Inc. GEOTECHNICAL ENGINEERING STUDY . PEPPERWOOD RESIDEN11AL DEVELOPMENT 8526 MAIN STREET EDMONDS, WASHINGTON E-10075 This report presents geotechnical recommendations for the proposed Pepperwood Residential Development to be located at 8526 Main Street, Edmonds, Washington. The general location of the site is shown on the Vicinity Map, Plate 1. The approximate iocations of the test pits and the approximate limits of the property are illustrated on the Test Pit Location Plan, Plate 2. Our scope of services included a subsurface exploration to characterize soil conditions at the site, and preparation of this report with geotechnical recommendations for the proposed site development. We understand development of the site will consist of a 22-lot subdivision and construction of a storm water detention vault. New access roadways will be,constructed throughout the property, and will connect to Main Street on the upper east half of the property and Pioneer Way along the lower west portion of the property. At the time this geotechnical engineering study was prepared, a final grading plan had not been completed. However, we anticipate that cuts and fills will be necessary to establish the building lot and roadway grades. Construction of a storm water detention vault is proposed for the lower west portion of the site, along the new access roadway that will connect to Pioneer Way. Cuts for the detention vault will probably be in the range of twelve (12) to sixteen (16) feet. Cuts along the toe of the existing steep slopes will likely be necessary to establish roadway grades for the new access roadway that will connect to Pioneer Way. The use of rockeries may be necessary to transition grades in landscaping areas and to provide permanent erosion control along cuts. Reinforced rockeries may also be utilized along the back of the building lots located at- the top of the slope areas. Preliminary design information indicates that the alignment of the reinforced fill r6ckery may be located on the existing slopes. Earth Consultants, Inc. GEOTECHNICAL ENGINEERNG STUDY Phoenix Development, Inc. E-10075 May 14, 2002 Page 2 An existing rockery along Main Street will be maintained and incorporated into the final development., The existing rockery is up to approximately ten (10) feet -to twelve (12) feet in height and was likely constructed during widening and improvements to Main Street. An assessment of the existing rockery is provided in the Ro6keries section of this report. The use of relatively lightly loaded wood frame construction is anticipated for the proposed single family residences. We estimate wall loads will be in the range of one to two kips per lineal foot, and column loads in the range. of ten (10) to twenty (20) kips. If the above design criteria are incorrect or change, ECI should be notified and allowed to review the recommendations contained in this report. In any case, ECI should be retained to perform a general review of the final design. SITE CONDITIONS Surftce r The approximate property limits and site topography are illustrated on the Test Pit Location Plan (Plate 2). The majority of the site is undeveloped and heavily vegetated, with the exception of s.everal rental homes located along Main Street. The topography is partitioned into two halves, with a slope area approximately bisecting the site in a north - south direction. The slopes descend to the west at grades of approximately 30 percent to 40 percent. The overall height 6 f -the slope ranges from approximately forty (40) to fifty (50) feet. Based on the site survey prepared by Group Four Inc., the steep slope areas within the planned development are limited to the north end of the property adjacent to Building Lot 9. The upper east half of the property is relatively flat, with gently sloping areas that descend to the east. An existing rockery and steep driveway area are located at the northeast cor.ner of the site. As previously discussed, the existing rockery will be incorporated into the new development, and the driveway areas will likely be filled to create a level- building lot area. The maximum height of the existing rockery is' approximately ten (110) to twelve (112) feet. The lower west portion of the development area is located at the toe of the existing slope that approximately bisects the property in a north -south direction. The immediate toe area of the site is relatively flat, and is located along an existing utility easement -corridor that connects to Main Street on the north and Pioneer Way on the south. On the extreme west side of the property, west of the utility easement, there is an area of ascending steep slopes. Development is not planned in this area. Earth Consultants, Inc. I I 't I . -'1) GEOTECHNICAL ENGINEEPJNG STUDY Phoenix Development, Inc. E-1 0075 May 14, 2002 Page 3 Steep Slope Evaluation At the time our field exploration was performed (March 2002), the steep slope areas of the site were observed for signs of instability or severe erosion. based on our observations, the steep slope areas appear stable. There were no indications of shallow or deep seated slide activity. The slope areas are generally heavily. vegetated with mature Douglas Fir, and there were no indications of severe erosion due to surface water runoff. Based on our observations, it appears the slopes are stable. Subsurface Eleven test pits were excavated throughout the site. The test pits were exc , avated to depths of approximately five to eight feet, where very dense glacial till soil conditions were encountered. Please refer to the test pit logs, Plates A2 through Al2, for a description of the conditions encountered at the test pit locations. The soils encountered at the test pit locations consisted of medium dense to very dense silty sand with gravel (Unified Soil Classification SM). Sand deposits were occasionally observed throughout the glacial till deposit. The depth of the topsoil layer varied, and typically ranged between two inches to twelve (12) inches. The geologic map of the area identifies the silty sand with gravel deposit as glacial till. The upper three to four feet of the soil deposit generally consisted of weathered glacial till. The weathered till was in a medium dense condition, and was characterized by brown to dark brown coloring. Dense to very dense unweathered glacial' till was encountered below the weathered glacial till layer. The unweathered glacial till was generally characterized by a gray to dark gray coloring. Fill was observed at test pit locations TP-4 and TP-5. The fill consisted of loose silty sand soils, and extended to depths of four to five feet. Yard waste piles were also observed along the top of the steep slope area in the vicinity of Test Pits TP-4 and TP-5. At the time the test pit exploration was performed (March 2002), the upper deposit of weathered glacial till was generally in, a wet condition. Laboratory testing indicates moisture contents of approximately 13 to 16 percent, or greater for the weathered glacial till. The lower deposit of unweathered glacial till was in a moist to wet condition, and had moisture contents generally in the range of approximately 8 percent'to 10 percent. Earth Consultants, Inc GEOTECHNICAL ENGINEEFUNG STUDY Phoenix Development, Inc. E-10075 May- 14, 2002 Page 4 Groundwater Groundv%oter seepage was not observed at the time of our exploration (March 2002). The presence of light to moderate groundv%eter seepage, however, should be expected in deep excavations. Based on the conditions observed at the time of our field exploration, we do not anticipate groundv%ater seepage will adversely impact the earthwork. Groundwater seepage levels and the rate of seepage are not static; fluctuations in the level and rates can be expected depending on the season, amount of rainfall, surface water runoff, and other factors. Generally, the level and rate of seepage is higher in the wetter winter months (typical ly,October through May). Laboratory Testing The results of laboratory tests performed on specific samples are provided in Appendix B, or at the appropriate sample depth on the test pit logs. It is important to note that these test results may not accurately represent the overall in -situ soil conditions. Our geotechnical recommendations are based on our interpretation of these test results. ECI cannot be responsible for the interpretation of these data by others. DISCUSSION AND RECOMMENDATIONS General Based on the subsurface conditions observed at the test pit locations, development of the site is feasible from a geotechnical standpoint. The proposed single family residences can be supported on conventional spread and continuous footings bearing on the medium dense to dense glacial till soils observed at the test pit locations. The building foundations can also be supported on structural fill soils that are used to modify the existing site grades. The medium dense to dense glacial till soil suitable for support of foundations was generally observed at a depth of approximately two feet below the native ground surface elevation. Earth Consultants, Inc. GEOTECHNICAL ENGINEENNG STUDY Phoenix Development, Inc. E-10075 May 14, 2002 Page 5 Due to the dense condition of the glacial till soils and the stable condition of the steep slope area, a minimum steep slope buffer of ten (10) feet from the top and toe of the steep slope areas can be considered for the proposed single-family residences. As previously discussed, the site survey prepared by Group Four, Inc. indicates that the steep slope areas within the planned development area are limited to the north end of the site, adjacent to Building Lot 9. In our opinion, reinforced fill rockeries can be successfully constructed on the existing steep slope, provided an engineered rockery design is completed. Steep slope buffer and foundation recomme ndations are provided in the Steep Slope Buffer and Foundations sections of this report. Preliminary rockery design recommend ations'are provided in the Rockedes section of this report. In our opinion, the majority of the existing rockery located along Main Street can be utilized and incorporated into the new development. Several of the existing rocks along the upper row of the rockery, however, will need to be replaced due to severe weathering. ECI will work with the contractor to identify the rocks that need to be replaced. With regard to the existing driveway areas that will likely be filled and brought up to the level of the existing rockery, the use of a geogrid reinforced fill will be necessary where the fill heights exceed approximately four feet. An engineered rockery design will also be needed for the proposed fill areas along the alignment of the existing Main Street rockery. In our opinion,.constr uction of the proposed storm water detention vault is feasible from a geotechnical standpoint. Medium dense todense glacial till soil will likely be encountered in the excavation for the storm water detention vault. Based on the conditions observed at the test pit locations, groundv%ate'r seepage may be encountered in the excavation for the storm water detention vault. However, in our opinion, groundv%ater seepage will likely not adversely impact the stability of the detention vault excavation. Recommendations for temporary excavations are provided in the Excavations and Slopes section of this report.. Cuts will be performed for the proposed access roadway that will connect to Pioneer Way. These cuts may encroach into the toe of the existing steep slope areas on the west s.ide of the property. Due to the dense glacial till soil conditions observed at the site, it is our opinion the roadway cuts will not compromise the stability of the slopes. We anticipate the roadway cuts will not exceed, six feet along the toe of the steep slopes. In our opinion, construction of a rockery along the planned roadway cuts can be considered. Earth Consultants, Inc. GEOTECHNICAL ENGINEEFJNG STUDY Phoenix Development, Inc. May 14, 2002 E-1 0075 Page 6 This geotechnical engineering study has been prepared for the exclusive use of Phoenix Development,. Inc. and their representatives. This study was prepared for specific application to this project only and.in a manner consistent with that level of care and skill ordinarily exercised by other members of the profession currently practicing under similar conditions in this area. No other warranty, expressed or, implied, is made. We recommend that this geotechnical engineering study, in its entirety, be included in the project contract documents for the information of the contractor. Site Preparation and General Earthwork The proposed development areas of the site should be stripped and cleared of existing surface vegetation, topsoil, existing structures, and other deleterious materials. Existing utility pipes that will be abandoned should be plugged or removed. Based on the conditions observed at the test pit locations, the thickness of the topsoil layer ranges between approximately two (2) inches to twelve (12) inches. The thickness of the topsoil layer will vary throughoutthe site. The ground surface where structural fill, or foundations. are to be placed should be observed by a representative of ECI. An ECI representative should also observe the excavation for the proposed storm water detention vault and roadway cuts. Existing fill soil and organic debris that is encountered in the building and vault foundation excavations should be overexcavated. Due to the relatively high fines content of the native soils, moisture sensitivity, of the soils will be moderate to high. Building and pavement subgrade areas that are exposed to extended periods of precipitation will likely become unstable. If the subgrade soil in the proposed foundation and pavement areas becomes saturated and unstable, overexcavation of the unstable soil and replacement with structural fill may be necessary. In our opinion, the majority of the native soils can be considered for use as structural fill, provided the soil is placed during dry weather conditions, and provided the moisture content of the soil is at or near the'optimum moisture content at the time of placement. At the time of the subsurface exploration (March, 2002) the upper deposit of weathered glacial till was generally in a wet condition. Laboratory testing indicates moisture contents of 13 percent or greater for the weathered glacial till. The lower deposit of unweathered glacial till was generally in a moist to wet condition, and had moisture contents of approximately 10 percent. ECI will work with the contractor to assess the suitability. of the on -site soils for use as structural fill. Earth Consultants, Inc. GEOTECHNICAL ENGINEEFUNG STUDY Phoenix Development, Inc. E-10075 May 14, 2002 Page 7 Imported soil intended for use as structural fill should consist of a fairly well graded granular soil with a moisture content that is at or near the optimum moisture content, and having a maximum aggregate size of four inches. During wet weather conditions, imported fill should consist of a fairly well graded granular material having a maximum size of four inches and no more than 5 percent fines passing the No. 200 sieve based on, the minus 3/4-inch fraction. Structural fill is defined as compacted fill placed under foundations, roadways, slabs, pavements, or other load -bearing areas. Structural fill under slabs and footings should be placed in horizontal lifts not exceeding twelve (12) inches in loose thickness and compacted to a minimum of 90 percent of its laboratory maximum dry density. The maximum dry density should be determined in accordance with ASTM Test Designation D-1 557-91 (Modified Proctor). The fill materials should be placed at or near the optimum moisture content. Fill under pavements and walks should also be placed in horizontal lifts and compacted to 90 percent of the maximum dry density except for the top twelve (12) inches, which should be compacted to 95 percent of the maximum dry density. If a structural fill berm is necessary to construct the storm water detention pond, the fill should be compacted to at least 95 percent of the maximum dry density. Steep Slope Buffer In our opinion, due to the dense condition of the glacial till soils observed at the site, and the stable condition of the existing slope areas, a minimum ten (10) foot buffer from the top and toe of the steep slope areas can be considered for the proposed single-family' residences. The City of Edmonds Development Standards. for Geologically Hazardous Areas are found under Title 20 (Chapter 20.15B). The Development Standards allow the required buffer distance to be reduced from fifty (50) feet to ten (110), feet, provided a geotechnical report can demonstrate that no adverse impacts to the slope or surrounding developments, will result. In our opinion, reducing the buffer distance to ten (10) feet will not adversely impact the stability of the steep slope areas. The observed stability of the existing slope and the presence of dense glacial till soils is the primary basis for this recommendation. Earth Consultants, Inc. GEOTECHNICAL ENGINEERING STUDY Phoenix Development, Inc. E-10075 May 14, 2002 Page 8 In our opinion, grading and the placement of fill on the slope will not adversely impact the stability of the slope. We understand fill placement along the backside of the upper building lots adjacent to the slope areas may be necessary to establish relatively level backyard areas. Reinforced fill rockeries can be used to transition the grade between the fill and the slope. In our opinion, due to the dense glacial till soil conditions, fill and rockery placement on the slope will not adversely impact the stability of the slope. As previously discussed, an engineered reinforced rockery design should be completed for 'the proposed fill and rockery areas. Foundations In our opinion, the proposed single family residences can be supported on conventional spread and continuous footings bearing on the medium dense to dense glacial till soil observed at the test pit locations. Where necessary, the proposed building foundations can also be supported on structural fill that is used to modify the existing site grades. Foundations should not be supported on the existing fill soils. The medium dense to dense glacial till soils suitable for support of foundations was generally observed at a depth of approximately two. feet below the native ground surface elevation. For foundations bearing on the medium dense to dense glacial till soil or structural fill, an allowable soil bearing capacity of two thousand five hundred (2,500) pounds per square foot (psf) can be used. This allowable soil bearing capacity has a facto r-of-safety in excess of 3.0 against shear failure, provided the foundations are placed on competent native soils or structural fill. A one-third increase in the above. allowable soil bearing capacity can be assumed for short-term wind and seismic loading conditions. Continuous and individual spread footings should have minimum widths of eighteen (18) and twenty- four (24) inches, respectively. If loose or unstable soil conditions are encountered at the footing subgrade elevation, the soil should be overexcavated, and replaced with structural fill. The width of the overexcavation should extend a minimum of six inches beyond each edge of the foundation. Exterior foundations elements should be placed at a minimum ' depth of eighteen (18) inches below final exterior grade. Interior spread foundations can be placed at a minimum depth of twelve 0 2) inches below the top of slab, except in unheated areas, where interior foundation elements should be founded at a� minimum depth of eighteen (18) inches. Earth Consultants. Inc. GEOTECHNICAL ENGINEERING STUDY Phoenix Development, Inc. E-10075 May 14, 2002, Page 9 Provided the foundations are placed in accordanc e with the recommendations contained in this report, -we estimate total settlement of approximately one inch and differential settlement of approximately one half inch. Most of the anticipated settlements should occur during construction as dead loads are applied. Lateral loads can be resisted by friction between the base of the foundation and the supportrig soil, and by passive soil pressure acting on the face of the buried portion of the foundation. Resistance to lateral loads from passive earth pressures can be calculated using an equivalent fluid with a unit weight of three hundred fifty (350) pounds per cubic foot (pcf). To achieve adequate passive resistance, the foundations must be backfilled with structural fill. As an alternative, the foundations can be poured neat against the undisturbed native soil. For frictional capacity, *a coefficient of 0.40 can be used for foundations bearing on competent native soils or structural fill. These lateral resistance values are allowable values; a facto r-of-safety of 1.5 has been included. Footing excavations should be observed by a representative of ECI prior to placing the formwork and repar. ECI should also observe areas where overex.cavation is required to remove loose or unstable soils. Permanent Retaining and Foundation Walls Retaining'and foundation walls should be. designed to resist lateral earth pressures from the retained soils, and any surcharge I oading. Walls that are unrestrained and free to move at the top can be designed using an equivalent fluid with a unit weight of thirty-five (35) pcf. The earth pressure imparted on restrained walls should be calculated using an equivalent fluid with a unit weight of fifty (50) pcf. The above equivalent fluid values assume surcharges due to traffic, adjacent foundations, construction loads, or any other loadings will not apply. If surcharges are to apply, they should be added to the above design lateral, pressures. For traffic surcharge loading, a uniform pressure of seventy (70) psf should be applied in a rectangular distribution along the height of the retaining wall. If sloping backfill conditions are present behind the walls, ECI should review the slope configurations and provide modified equivalent fluid values, as necessary. Earth Consultants, Inc. GEOTECHNICAL ENGINEERING STUDY Phoenix Development, Inc. E-10075 May 14, 2002 Page 10 Retaining and foundation walls should be provided with a four inch diameter perforated drainpipe and backfilled with a free -draining granular soil with less than 5 percent fines (percent passing the No. 200 sieve based on the minus % inch fraction). The zone of free -draining granular soil should extend along the entire height of the wall, and a distance of at least eighteen (18) inches behind the wall. A surface seal consisting of a less permeable silty sand soil can be placed along the upper one foot of the wall backfill, if desired. The remainder of the backfill behind the zone of free draining soil should consist of a suitable granular structural fill. Seismic Design Considerations The Puget Sound region is classified as Zone 3 by the Uniform Building Code (UBC). The largest earthquakes in the Puget Sound region have been subcrustal (intraplate) events, ranging in depth from fifty (50) to seventy (70) kilometers. Such deep events have exhibited no surface faulting. Weaver and Shedlock (1989) researched the probable or known source areas for the crustal, intraplate, and subduction zone earthquakes in the Washington and Oregon area. Crustal and intraplate earthquakes are the only events in Washington and Oregon in which there is a historical record. Shallow crustal earthquakes occur within the North American Plate, and typically do not exceed focal depths of approximately 20 kilometers. Intraplate earthquakes occur in the subducting Juan de ,Fuca plate, and typically occur below depths'of 40 kilometers. The recent February 28,, 2001 earthquake that was focused just north of Olympia, Washington. was an intraplate earthquake, and had a magnitude Of ML =6.8. The subduction zone earthquake, in which there is no historical record in the Washington and Oregon area, would have its source along the interface between the North American Plate and the subducting Juan de Fuca Plate. Magnitude 8+ earthquakes are thought to be possible along this interface, and would occur at depths of approximately 50 to 60 kilometers (Weaver and Shedlock, 1989). The UBC Earthquake regulations have established a series of soil profile types that are used as a basis -for seismic design of structures. Based on the encountered soil conditions, it is our opinion that soil type Sc from Table 16-J of the 1997 UBC should be used for design. Liquefaction is a phenomenon in which soils lose all shear strength for short periods of time during an earthquake. The effects of liquefaction may be large total and/or differential settlement for structures with foundations founded in the liquefying. soils. Groundshaking of sufficient duration results in the loss of grain -to -grain contact and rapid increase in pore water pressure, causing the soil to behave as a fluid for short periods of time. Earth ConstAtants, Inc. GEOTECHNICAL ENGINEEFING STUDY Phoenix Development, Inc. E-10075' May 14, 2002 Page 11 To have potential for liquefaction, a soil must be cohesionless with a grain size distribution of a specified range (generally sands and silt); it must be loose to medium - dense; it must be below the groundvQter table; and it must be subject to sufficient magnitude and duration of groundshaking. Based on the soil and groundv%eter conditions observed at the site, it is our opinion that the site has a low susceptibility to liquefaction. The dense condition of the native soils is the primary basis for this conclusion. Slab -on -Grade Floors Slab -on -grade floors can be supporled on competent native soils or structural fill. Loose or unstable subgrade soils should be stabilized prior to construction of the slab. The use of a geo textile and crushed rock can be considered for stabilizing the subgrade soils, if necessary. A four -inch capillary break consisting of a free draining poorly graded sand or gravel with less than 5 percent fines (percent passing the No. 200 sieve, based on the minus 3/4-inch fraction) should be placed below the slab. In areas where slab moisture is undesirable, a vapor barrier such as a 6-mil plastic membrane can be placed beneath the free draining sand or gravel. The subgrade soils in slab -on -grade areas of the site should be observed by a representative of ECI prior to placing the capillary break material. Site Draingge During construction, surface water runoff must not be allowed to stand in construction areas. IrIterceptor trenches should be established, as necessary, along the perimeter of the building site before it enters the construction. area. During construction, loose surfaces should be compacted to reduce the potential for moisture infiltration into the soils. Finish grades around the buildin gs must be sloped such that surface water is directed away from the buildings. Perimeter footing drains should be installed around the perimeter foundations to intercept groundv%eter seepage. A typical perimeter footing drain detail is illustrated on Plate 3. Under no circumstances should roof downspout drain lines be connected to the footing or foundation wall drain systems. All roof downspouts must be separately tightlined to the site storm water system. Earth Consultants, Inc. GEOTECHNICAL ENGINEEFJNG STUDY Phoenix Development, Inc. E-10075 May 14, 2002 Page 12 Excavations and Slopes The following informatio n is provided solely as a service to our client. Under no circumstances should this information be interpreted to mean that ECI is assuming responsibility for construction site safety or the contractor's activities; such responsibility is not being implied and should not be inferred. In no case should excavation slopes be greater than the limits specified in local, state, and Federal safety regulations. - Based on the information obtained from our field exploration, the upper deposit of weathered glacial till that extends to a depth of approximately four feet below existing site grades would be classified as Type C soils by OSHA. The existing fill observed at the site would also be classified as Type C soil. Temporary cuts in Type C soils should be sloped at an inclination no steeper than 1.51-11 V (Horizontal: Vertical), respectively. The unweathered glacial till observed below a depth of approximately four feet would be classified as Type A and Type B 'Soils by OSHA. Temporary slopes constructed in Type A and Type B soils should be inclined no steeper than 0.75H: 1 V and 1 H: 1 V, respectively. ECI should observe the excavations to assess soil and groundv%eter conditions, and to verify the OSHA soil type. Permanent cut and fill slopes should be inclined no steeper than 2H: 1 V. Cut slopes should be observed by ECI during excavation to verify that conditions are as anticipated. Supplementary recommendations can then be developed, if needed, to improve stability, including flattening of slopes or installation of surface or subsurface drains. In any case, water should not be allowed to flow uncontrolled over the top of slopes. Permanently exposed slopes should be seeded with an appropriate species of vegetation to reduce erosion and improve stability of the surficial layer of soil. Utilily Trench Backfill Based on the soil conditions encountered at the time of our exploration, the native soils should. provide adequate support for utilities. If remedial measures are necessary to provide adequate support for utilities, the unsuitable soils can be overexcavated and replaced with a rock ballast and pipe bedding material such as pea gravel. The presence of groundv%eter seepage should be expected in the deeper utility trench excavations and the proposed detention vault excavation. Earth Consultants. Inc. GEOTECHNICAL ENGINEEFUNG STUDY Phoenix Development, Inc. E-1 0075 May 14, 2002 Page 13 in our opinion, the native soils can be considered for'use as backfill for the utility trenches. At the time of the subsurface exploration (February, 2002) the upper deposit of weathered glacial till was generally in a wet condition, with moisture contents in excess of 16 percent. The lower deposit of unweathered glacial till was generally in a moist to wet condition, and had moisture contents of approximately, 10 percent. ECI will work with the contractor to assess the suitability of the on -site soils for use as utility trench backfill. As previously mentioned, the soil should be placed during dry weather conditions, and the moisture content of the soil should be, at or near its optimum moisture content at the time of placement. Utility trench backfill is a primary concern in reducing the potential for settlement in pavement areas. It is important that the utilities be adequately supporied in the bedding material. The material should be hand tamped to ensure support is provided around the haunches of these structures. Fill should be carefully placed and tamped to about twelve 0 2) inches above the crown of the pipe before heavy compaction equipment is brought into use. The remainder of the backf ill should be placed in lifts having a loose thickness of less than twelve (12) inches. A typical trench backfill section and compaction requirements for load supporting and non -load supporting areas is presented on Plate 4. Rockeries We understand the existing rockery located along Main Street at the northeast portion of the site will be incorporaled into the new development. The rockery is approximately 180 feet in length, and ranges between four (4) feet to twelve (112) feet in height. We estimate the rockery has been in place for appro)dmately twenty-five years. Two existing driveways that ramp up through the alignment of the rockery face will be filled as part of the proposed development to establish a level building lot area. Construction of new reinforced fill rocke'ries is currently being considered for purposes of retaining the new fill. As discussed previously, an engineered rockery design will need to be completed for the reinforced fill rockeries proposed for the site. Based on our observations, the majority of the existing rockery has experienced minor to moderate weathering. The minor to moderate weathering was primarily observed along the lower rows of the rockery. In our opinion, these rocks are still structurally sound and will not have to be replaced. Several of the upper rocks have experienced severe weathering, and should be replaced. These rocks are located primarily along the higher portions of the rockery. ECI will work with the contractor in identifying rocks that should be replaced. Earth Consultants, Inc. GEOTIECHNICAL ENGINEEFUNG STUDY Phoenix Development, Inc. E-10075 May 14, 2002 Page 14 Pavement Areas The adequacy of site pavements is related in part to the condition of the underlying subgrade. To provide a properly prepared subgrade for pavements, the subgrade should be in a firm and unyielding condition when subjected to proofrollin'g with a loaded dump, truck: Structural fill in pavement, areas should be prepared as described in the Site Preparation , and General Earthwork section of this report. This means the pavement subgrade should be compacted to at least 95 percent of the maximum dry density. It is possible that some localized areas of soft, wet or unstable subgrade may exist after the pavement subgrade is prepared. Overexcavation and a greater thickness of structural fill or crushed rock may be needed to stabilize these localized areas. A biaxial geogrid such as Tensar BX-1 200 can be considered for use below the crushed rock where bridging of unstable subgrade is necessary. Assuming a properly prepared subgrade, the following pavement section for lightly -loaded areas can be used: Two inches of asphalt concrete (AC) over four inches of crushed rock base (CRB) material, or 0 Two inches of AC over three inches of asphalt treated base (ATB) material. Heavier truck -traffic areas will requiee thicker pavement sections depending upon site usage, pavement life, and site traffic. If necessary, ECI can provide pavement design recommendations for truck traffic areas. Asphalt concrete (AC), asphalt treated base (ATB), and crushed rock base (CRB) materials should conform to WSDOT specifications. All rock bases should be compacted to at least 95 percent of the maximum dry density. LIMITATIONS Our recommendations and conclusions are based on the site materials observed, 'Selective laboratory testing and engineering analys6s, the design information provided. to us, and our experience and engineering judgement. The conclusions and recommendations are professional opinions derived in a manner consistent with that level of care and skill ordinarily exercised by other members of the profession currently practicing under similar conditions in this area.- No warranty is expressed or implied. Earth Constiltants, Inc. Non -Load Supporting Floor Slab or Areas Roadway. Areas Backfill Bedding LEGEND: Varies I Foot Minimum Varies Varies Asphalt or Concrete Pavement or Concrete Floor Slab I o o I Base Material or Base Rock 1. 0. . . Backfill; Compacted On -Site -Soil or Imported Select Fill Material as Described in the Site Preparation of the General Earthwork Section of the Attached Report Text. Minimum Percentage of Maximum Laboratory Dry Density as Determined by ASTM Test Method D 15*57-91 (Modified Proctor), Unless Otherwise Specified in the Attached Report Text. Bedding Material; Material Type Depends on Type of Pipe and Laying Conditions. Bedding Should Conform to the Manufacturers Recommendations for the Type of Pipe Selected. TYPICAL UTILITY TRENCH FILL Earth Consultants Inc. Pepperwood Edmonds, Washington. Prol. NO. 100775 Drwn. GLS Date Apr. 2002 Checked RAC Date 4/12/02 Plate 4 APPENDIX A FIELD EXPLORATION E-10075 Our field exploration was performed on March 28, 2002. Subsurface conditions at the site were explored by observing a total of eleven test pit excavations. The test pits were excavated by a subcontractor of Phoenix Development, Inc. The approximate test pit locations were determined from existing landmarks presented on available plans. The locations of the test pits should be considered accurate only to the degree implied by the method used. These approximate test pit locations are shown on the Test Pit Location Plan, Plate 2. 1 The field exploration was -continuously monitored by a geologist from our office, who classified the soils encountered and maintained a log of each test pit, obtained representative samples, measured groundv%eter levels, and observed pertinent site features. All samples were visually classified in accordance with the Unified Soil Classification System that is presented on Plate Al, Legend. Logs of the test pits are presented in Appendix A, Plates A2 through Al2. The final logs represent our interpretations of the field logs and the results of the laboratory tests of field samples. The stratification lines on the I ogs represent the approximate boundaries between soil types. In actuality, the transitions may be more gradual. Earth Consultants, Inc. GRAPH LETTER MAJOR DIVISIONS iSYMBOL SYMBOL TYPICAL DESCRIPTION P C3 C3 ( GW Well -Graded Gravels, Gravel -Sand Gravel �4.�OAOA gW Mixtures, Little Or No Fines And Clean Gravels 41111111k q& Poorly -Graded Gravels, Gravel - Gravelly (little or no fines) Coarse Soils 7"-g-p— Sand Mixtures, Little Or No Fines Grained GM Silty Gravels, Gravel - Sand - Soils More Than 50% Coarse Gravels With Mae g M Silt Mixtures Vraction Fines (appreciable G �gc Clayey Gravels. Gravel - Sand - Retained On amount of tines) - No. 4 Sieve V �� Clay Mixtures Sand Sw Well -Graded Sands, Gravblly And Clean Sand SW Sands, Little Or No Fines More Than Sandy Soils I little or no fines) SP Poo ly-Graded Sands, Gravelly 50% Material SP Sands, Little Or No Fines Larger Than More Than SM No. 200 Sieve 50% Coarse Sands With SM Silty Sands. Sand - Sift Mixtures Size Fraction Fines (appreciable aw SC SC Clayey Sands, Sand -Clay Mixtures Passing No. 4 Sieve amount of fines) . Inorganic Silts & Very Fine Sands, Rock Flotr,Silty- MI Clayey,Fine Sands; Clayey Silts w/ Slight P lasticity Fine Silts Liquid Limit L Inorganic Clays Of Low To Medium Plasticity, Grained And Less Than 50 Cl Gravelly Clays. Sandy Clays, Silty Clays, Lean Soils Clays Organic Silts And Organic Silty Clays Of Low, Plasticity MH Inorganic Silts. Micaceous Or Diatomaceous Fire .More Than Mh Sand Or Silty Soils 50% Material Smaller Tfan Silts Liquid Limit And Inorganic Clays Of High No. 200 Sieve Greater Than, 50 Clays _�H —�c h Plasticity, Fat Clays Size 7Z Z Z Z OH Organic Clays Of Medium To'High R Oh Plasticity, Organic Silts L1_1_' LI-1k, A1.1-j P Peat, Humus, Swamp Soils Highly Organic SoiI6 Pt With High Organic Contents Topsoil 4 *11 41 Humus And'Duff Layer Fill Hi$,hly Variable Constituents The discussion in the text of this report is necessary for a proper understanding of the nature of the material presented in the attached logs. DUAL SYMBOLS are used to indicate bordedine soll claseffication. , C TORVANE READING, tsf 2' O.D. SPLIT SPOON SAMPLER qu PENETROMETER READING, tsf W MOISTURE, % dry weight 24' I.D. RING OR SHELBY TUBE.SAMIPLER P SAMPLER PUSHED SAMPLE NOT RECOVERED WATER OBSERVATION WELL pcf DRY DENSITY, lbs. per cubic ft. LL� LIQUID LIMIT, % sZ DEPTH OF ENCOUNTERED GROUNDWATER P1 PLASTIC INDEX DURING EXCAVATION 7 SUBSEQUENT GROUNDWATER LEVEL W/ DATE Earth Consultants Inc. LEGEND Proj. No. 100751 Date Apr. 2002 1 Plate Al Test Pit Log Project Name: Pepperwood Sheet of 1 1 1 Job No. 10075 Logged by: � KCS Date: 3/28/02 Test Pit No.: TP-1 Excavation Contactor UniversalLand Ground Surface Elevation: 420'. Wes: General Notes W M .2 -5 �Q E Cn CL E (0 -1.0 E (0 Surfaoe. Conditions: Depth of Topsoil & Sod 4": grass 13.3 16.4 15.4 14.5 2 3 4 5 6 7 SM Brown silty SAND with gravel, loose, moist -30% fines ML Gray sandy SILT, medium dense, moist SM -mottlinq at 5 Gray silfy SAND, medium dense to dense, moist Test pit terminated at 7.5 feet below e)dsbng grade. No groundwater encountered during excavation. NOTES: Elevations estimated by a Topographic Site Plan provided by the Client Survey by Group Four Inc. dated 1/6/99. Earth Consultants Inc. Test Pit Log Pepperwood Edmonds, Washington Proj. No. 10075 Dwn. GLS Date Apri12002 checked KCS Date 4/10/02 Plate A2 Subsurface condiltions depicted represent our observations at the time and location of this exploratory hole, modffied by engineering tests, analysis and judgment They are not necessarily representative of other times and locations. We cannot accept responwbility for the use or interpretation by others of __#_q - 44'i. I- Tesf Pit Log Project Name: Pepperwood Sheet or 1 1 1 Job No. 10075 Logged by- 1 KCS Date: 3/28/02 Test Pit No.: TP-2 Excavation Contactor. Universal Land Ground Surface ELm�ation: 424' Notes: General Notes W (0/11) 2 'r- rL E E! >' CL 0- G_ E , a U) 0) 0 , , M rn E =) >' CO Surface Conditions: Depth of Topsoil & Sod 19': ferns 11.9 ........ 2 3 4 5 6 7 SM Brown silty SAND with gravel, loose, moist -roots may e)dend to 3' mottling at 4' SM Brown silty SAND, dense, moist -15% fines Test pit terminated at 7.0 feet below eAsting grade. No groundwater encountered during e)cavation. Eafth Consultants Inc. Test Pit Log Pepperwood Edmonds, Washington Pr4 No. 10075 'T_Z� GLS Date April 2002 checked KCS Date 4/10102 Piate A3 --WMUrtaoe OMMons depKIed represent our observ"-ns at the Ume and location of this wploratory hole, modiffied by engineering tests, analysis and judgment They are not necessarily representative of other times and loications. We cannot accept responsibility forthe use or interpretation by others of Test Pit Log Project Name: PeppenNood Sheet of Job No. 10075 Logged by- 1 KCS Date. 3/28/02 Pit No.: TP-3 Excavation Contactor Universal Land Ground Surface Elevation: 416' Notes: General Notes W M) 0 -6 8 cL E 120 >, T CL E M U) -6 '0 E >' (n Surface Conditions: Depth of Topsoil & Sod 2": trees and fems 10.6 7.1 ........ T'. 2 3 4 5 6 SM Brown silty SAND with gravel, loose, moist -wiffi some organics roots -mottling and iron o)dde staining at 3' SM Gray silty SAND with gravel, dense, moist Test pit terminated at 6.0 feet below e)dsbng grade. No groundwater encountered during e)cavation. Earth Consultants Inc. & FXM"Ul�ftral -',Ckv4L%% Test Pit Log Pepperwood Edmonds, Washington Prq. No. 10075 Dwn. GLS Date April 2002 Che&ed KCS Date 4/10102 Plate A4 Stmufface corMons depicted represent our observations at the time and location of this e)pbratory hole, modified by engineering tests, analysis and Luc�g=- ITZw:�tn=rily representative of other tknes and.bcations. We cannot accept responsibility for the use or interpretation by others of Test 'Pit Log "ect Nanie: Pepperwood -T Sheet of 1 1 Job No. 10075 Logged by: KCS Date: 3/28/02 Test Pit No.: TP-4 Excavation Contactor- Universal Land Ground Surfaoe Elevation: 404' Notes: General Notes w (0/0) .2 -6 �r- .0 OF E 6 2 CL E CO -6 �O E >' Surface Conditions: Depth of Topsoil & Sod 4": brush debris 11.2 7.7 16.9 -.0 2 3 4 5 6 7 8 SM Brown silty SAND with gravel, loose, moist — SP-SM Brown poorly graded SAND with silt and gravel, medium dense, moist, 5% fines SM Gray silty SAND with gravel, dense, moist to wet Test pit terminated at 8.0 feet below e)dsbng grade. No groundwater encountered during excavation. Fx-wh Consultants Inc. & Rrmnlnnx�ral Test Pit Log Pepperwood Edmonds, Washington Prq- NO. 10075 Dwn. GLS Date April 2002 ched(ed KCS [�e 4/10/02 Plate A5 �Suosurtaoe conortions; oepictea represent our observations at the Urne and location of this exploiattory hole, modified by engineering tests, analysis and f .�grnent-�� are not neoessarily representative of other tirnes and locations. We cannot acoept responsibility for the use or interpretation by others of ,fw —4�4 — thi. L-- TestPit Log 0 6 W t Prciect Nam: Pepperwood -T Sheet of I Job No. 10075 Logged by-. KCS Date. 3/28/02 Test Pit No.: TP-5 Excavation Contactor: Universal Land Ground Surface Elevation: 395' Notes: General Notes W M 0 :E �O CL E T >1 CL E Q Zno (n -6 , -. -0 rn E Surface Conditions: Depth of Topsoil & Sod 2": grass 10.8 10.8 TUAITI 2 3 4 6 7 SM Brown silty SAND with gravel, loose, moist SM Brown silty SAND with gravel, occasional cobbles, medium dense, moist -mottling at 7' SM Gray silty SAND with gravel, dense, moist (Weathered Till) Test pit terminated at 7.5 feet below eAsting grade. No groundwater encountered during e)cavation. FA-WhConsultants Inc. Test Pit Log Pepperwood Edmonds, Washington Prci- No. 10075 Dwn. GLS Date April'20 02 ched(ed KCS Date 4/10102 Plate A6 ZWOSuffam cw=ons dq'xaeO represent our observations at the time and location of this exploratory hole, modified by engineering tests, analysis and Vc,ont 1��wUtr=rily representative of other times and locations. We cannot accept responsibil4 for the use or interpretation by others of t Pit Log Project: Name: Pepperwood Sheet Of 1 1 Job No. 10075 Logged by: 1 KCS Date: 3/28/02 Test Pit No.: TP-6 Excavation Contactoc Universal Land Ground Surface Elevation: 395' Notes. General Notes W 2- E, CL u- E CO CO 0.0 in E Z) >� CO Surface Conditions: Depth of Topsoil & Sod 2": grass T. -,Of 4 2 3 4 5 SM Brown silty SAND with gravel, medium dense, moist -some mottling at 3'- 4' SP-SM Brown poorly graded SAND with silt medium dense, moist SM Gray silty SAND with gravel, dense, moist Test pit terminated at 5.5 feet below e)dsbng grade. No groundwater encountered during e)cavation. Fx-Mh Consultants Inc. Test Pit Log Pepperwood Edmonds, Washington Prui..No. 10075 Dwn- GLS Date Apri12002 checked KCS I Date 4/10/02 Plate A7 Subsurfacie conditions depicted represent our observations at the time and localikin of this e):p1oratory hole, modified by engineering tests, analysis and judgment They are not necessarily representative of other times and locations. We cannot accept responsibility for the use or interpretation by others of �OM—A — 4hi. t— Test Pit Log Project Nam: heet Pepperwood 71 1 -lob No. T LoMed by-, Date: Test Pit No.: 10075 KCS 3128102 TP-7 Excavation Contactor Ground Surface Elevation: Universal Land 408' Notes: 1! -6 Surface Conditions: Depth of Topsoil & Sod'7': grass General Notes W cL E 12 >- CL E M n E >' CO CO SM Brown silty SAND with gravel, loose, moist SP Brown poorly graded SAND with gravel, dense, moist 2 5-9 lv� Or 4 SM Gray silty SAND with gravel, dense, moist Test pit terminated at 5.5 feet below e)dsbng grade. No groundwater encountered during e)cavation. Test Pit Log Earth Consultants Inc. Pepperwood Edmonds, Washington 7Prq- No. 10075 Dwn. GLS Date Apri12002 amcked KCS Date 4/10/02 A8 ,�uusurTaoe corKnuons aep4aeo represent our onservations at the time and location of this wooratory hoie, modified by engineering tes;ts, anaWm and jtj!Lu�t 1�2 arLnot necessarily representative of other times and locations. We cannot accept responsibility for the use or interpretation by others of 44,i. I— GEOTECHNICAL ENGINEEFUNG STUDY Phoenix Development, Inc. E-10075 May 14, 2002 Page 15 The recommendations submitted in this report are based upon the data obtained from the test pits. Soil and ground%,Qter conditions between exploration sites may vary from those encountered. The nature and extent of variations between our exploratory locations may not become evident until construction. If variations do appear, ECI should be requested to reevaluate the recommendations of this report and allowed to modifyor verify our. recommendations in writing prior to proceeding With the construction. Additional Services We recommend that ECI be retained to perform a general review of the final design and specifications to verify that the earthwork and foundation recommendations have been properly interpreted and implemented in the design and in the construction specifications. We also recommend that ECI be retained to provide geotechnical services during construction. This is to observe compliance with the design concepts, specifications or recommendations and to allow design changes in. the event subsurface conditions differ from those anticipated prior to the start of construction. We do not accept responsibility for the performance of the foundati ' on or earthwork unless we are retained to review the construction drawings and specifications, and to provide construction observation and testing. Earth Consultants, Inc. A FOUS , T rk G LODY Llf VY -i ST T R A. RRAUEM SIEW 13 All A .0 '24 L I uL ST, 'W' �4 L Liz a;j OWMI 4— Z mitt - ELU�' WSo L 4 X J­ _ ST ­7 ST'F &DAR UY uY. �WCE d- ST W —.5u j'. I 214tH _2 115r '09 7 21 law IOU YlUt. 00A xt 3.. < ST 218TH ST FIR 7. 30 P::� I"W'SI 22( TH". ST WWI qt ZN—TWIL MST et Pt, 00 g .91 ST Reference: Puget Sound Area Snohomish County / Map 454 By Thomas Brothers Maps Dated 2002 NOTE: This plate may contain areas of color. ECI cannot be responsible for any subsequent misinterpretation of the information resulting from black & white reproductions of this plate. noEarth Consultants, Inc. Geotechnical Engineers, C--ologists & Environmental Scientists Vicinity Map Pepperwood Edmonds, Washington Drwn. GLS Date April 2002 Proj. No. 10075 Checked RAC Date 4112/02 Plate 1 !_1 LEGEND 390 J 10 I v I" 7. TP-1—ml —Approximate Location of ECI Test Pit, Proj. No. E-10075, Mar. 2002 Subject Site Existing Building 6 Lot Number NOTE: This plate may contain areas of color. ECI cannot be responsible for any subsequent misinterpretation of the information resulting from black & white reproductions of this plate. 420 Approximate Scale 77= 0 50 100 200ft. Earth Consultants, Inc. Geoted"cal Engmeers. Geologists & Environmental Scie-ViSts Test Pit Location Plan Pepperwood Edmonds, Washington Drwn. GLS Date April 2002 Proj. No. 10075 checked RAC Date 4112J02 Plate 2 Slope To Drain 6 inch min. 7 7, 00 CL 18 inch min. 4 inch min. Diameter, 0 Perforated Pipe Wrapped in Drainage Fabric 2 inch min. 2 inch min. 4 inch max. 12 inch min. SCHEMATIC ONLY - NOT TO SCALE NOT A CONSTRUCTION DRAWING LEGEND Surface seal; native soil or other low permeability material. Fine aggregate for Portland Cement Concrete; Section 9-03.1(2) of the WSDOT Specifications. Drain pipe; perforated or slotted rigid PVC pipe laid with perforations or slots facing down; tight jointed; with a positive gradient. Do not use flexible corrugated plastic pipe. Do not tie building downspout drains into footing lines. Wrap with Miraft 140 Filter Fabric or equivalent TYPICAL FOOTING SUBDRAIN DETAIL Earth Consultants Inc. Pepperwood Ce"od"cal Enorooem C&01D� & En%4r0mvWM1 Sck"IMS Edmonds, Washington Proj. No. 10075 [D-rwn. GLS Date Apr. 2002 Checked RAc [Date '4/12/02 Plate 3 TesrPit Log Project Name: Pepperwood 1 Sheet of 1 1 Job No. 10075 Logged by: KCS Date: 3/28/02- Test Pit No.: TP-8 Excavation Contactor: Universal Land Ground Surface Elevation: 416! Notes: General Notes w M -6 -0 CL 12 E (n A! El CL E Ca Z5 E Cn Surface Conditions: Depth of Topsoil & Sod 2": grass 21-2 11.3 2 3 4 Sm Brown silty SAND with gravel, loose to medium dense, moist sm. Gray silty SAND with gravel, dense, moist Test pit terminated at 4.5 feet below e)dsbng grade. No groundwater encountered during e)cavation. Eafth Consultants'Inc. Test Pit Log Pepperwood Edmonds, Washington Proi. No. 10075 Dwn. GLS Date Apri12002 checked KC S Date 4/10/02 Plate A9 butisurtaos conditions depicted represent our observations at the time and location of this e)pbratory hole, modified by engineering tests, analysis and ITa are not necessarily representative of other times and locations. We cannot accept responsibitity for the use or interpretation by others of Test Pit Log Project Name: Pepperwood Sheet of 1 1 1 Job No. 10075 Logged by- KCS Date: 3/28/02 Test Pit No.: TP-9 Excavation Contactor: Universal Land Ground Surface Bevation: 354' Notes: 'General Notes W (OM .2 -6 r- -0 '00- E R CL u- E (n CO 0 co E CO Surface Conditions: Depth of Topsoil & Sod 6': trees and blackberries 10.8 12.6 ... xxq.: 2 3 4 5 6 7 SM Brown silty SAND, loose to medium dense, moist SP-SM Grades to gray poorly graded SAND with silt medium dense, moist -becomes with gravel at 5' Test pit terminated at 7.0 feet below e)dsbng grade. No groundwater encountered during e)cavation. Earth Consultants Inc. Qtmeduik-dl - Fngftwr.� Q-ob�_ & FiMrmirj".Ikk-ntIsM Test Pit Log Pepperwood Edmonds, Washingto6 No. 10075 Dwn. GLS Date April 2002. KCS Date 4/10/02 Plate Al 0 Subsurface cmditions depicted neoessa=nt our observations at the time and location of this exploratory hole, modified by engineefing tests, anaVis and jn�. 'Tey are not i r, representative of other tirnes and locations. We cannot accept responsibility for the use or interpretation by others of Tei&it Log �Q' Project Narne- Pepperwood Sheet of 1 1 1 Job No. 10075 Logged by- KCS Date: 3/28/02 Test Oft No.: TP-10 Emuwation Contactor: Universal Land Ground Surface Elevation: 359' Notes: General Notes W M CL E CL & E co o E Surf" Conditions: Depth of Topsoil & Sod 12": ferns and trees 8.5 ... 2 3 4 5 SM Brown silty SAND with gravel, loose, moist SM Gray silty SAND with gravel, medium dense, moist -becomes dense at 5' Test pit terminated at 6.0 feet below e)dsting grade. No groundwater encountered during exravation. Eal-th Consultants Inc. Test Pit Log Pepperwood Edmonds, Washington Proi. No- 10075 Dwn- GLS Date April2002 checked KCS Date 4/10/02 subsurface conditions depicted represent our observations at the time and location of this exlftatory hole, fftcxffmd by engineering tests, analysis and judgrnent They are not necessarily representative of other firries and locations. We cannot accept responsibility for the use or interpretation by others of .�4-4 - fm. L-- it Log Proiect Narne. Pepperwood Sheet of I 1 1 JobNo. 10075 LoWed by:- KCS Ekde: 3/28/02 Test Pit No.: TP-1 1 Excavation Contactor Universal Land Ground Surface Elevation: 356' Notes: General Notes W -6 .0 E >' S VL CL 4, E C) M -6 0 n co E Surface conditions: Depth of Topsoil & Sod 12"Jerns, trees, blackberries 13.4 7-7 -4.4 A 2 3 4 5 6 SM Brown silty SAND with gravel, loose, moist SP -SM Brown poorly graded SAND with silt medium dense, moist SM Gray silty SAND with gravel, dense, moist Test pit terminated at 7.5 feet below e)dsting grade. No groundwater encountered during exr-avation. Earth Consultants Inc. Test Pit Log Pepperwood Edmonds, Washington Proj. No. 10075 Dwn. GLS Date Apri12002 Fchecked KCS Date 4/10/02 Tpue All 2 Subsurface conditions depicted represent our observations at the time and location of this exploratory hole, modified by engineedrq tests, analysis and am not necessarily repwmAaM of other firries and locations, We cannot accept responsibility for the use or interpretation by others of APPENDIX B LABORATORY TESTING RESULTS E-10075 Earth Constiltants, Inc. 6 Copies Reviewed By: Scott D. Dinkelman, CEG Associate Engineering Geologist DISTRIBUTION E-1.0075 Phoenix Development, Inc. P.O. Box 3167 Lynnwood, Washington 98046-0958 Attention: Ms. Loree Quade Earth ConstAtants, Inc. DATE RECEIVED PERMIT EXPIRES CITY OF EDMONDS USE PERMIT NUMBER CONSTRUCTION PERMIT APPLICATION JOB SUITE/APT# ADDRESS 19 C t.V, W OWNER NAME/NAME OF BtAINESS -6�cahj&l �1� MAILING ADDRESS T N ME/SUBDIVISION NO. FWO- 01 — 17t LOT NO. LD NO. L�D FEE $ ;tct 0 SQ PUBLIC RIGHT OF WAY PER OFFICIAL STREET MAP TIES P ad RW cr:1IP1r`.'V1 �.I'ad ZIP TELEPHONE I EXISTING — PROPOSED street Use Permit Req'd inspection Required REQUIRED DEDICATION alff FT Sidewalk Required Undergr=x1l Wiring req Ired .,NAME METER SIZE,, LINE I SIZE NO. OF FIXTURES �o PRV REQUIRED/ 13 13 r4k*-S 114, 1 'd, I YES NO X ADDRESS ltiE zo "s;b REMARKd OWNER/CONTRACTOR RESPONSIBLE FOR EROSION CONTROL/DRAINAGE z CITY aj&-cv&q� : n, uj I ZIP TELEPHONE -gm f6i.�41 i.AA-- PA1A1A.,r.'V2 grhe-411A&T I%-41V1r._,1 A— ::411 1M L IF NAME 'CB4 L# ENGINEERING REVIEWED BY j, I I'll. DATE CC 0 ADDRESS 9:� D BY FIRE REVIEWE DATE us CITY Z, PA TELEPHONEqts :747?.�- 0 rL STATE LICENSE NUMBER EXPIRATION �DATE'L ­VARIANCE.ORCLI'L�1.1� V-o3 - floq SHORELINE ORADR#; I - 110YES INSPECTION RE%0 ANO 1$ BOND POSTED — SEPA REVIEW COMPLETE EXEMPT SIGN AREA ALLOWED PROPOSED, HEIGHT -,ALLOW5p PROPO ;j PROPERTY TAX ACCOUNT'PARCEI:,!40. x 00-7 a .3/0 q NEW RESIDENTIAL PLUMBING - MECH, LOT COVERAGE ALLOWED REQUIRED SETBACKS (Ff� 'IFIlEAR `P60POSED SET ACKS (FT.) - a COtIMPLIANCE OR PR9,POSED 1`1`10tp� SIDE FRO .VT,,, 4R SIDE RE: Ez ADDITION COMMERCIAL CHANGE OF USE OK !q to', 19, z REMODEL MULTIFAMILY SIGN PARKING PIrE . R 'D D LOT AREA .11 77 a FENCE REPAIR CYDS FT) REMARKS* V-0� DEMOLISH TANK E] OTH I GARAGE RETAINING WALL FIRE SPRINKLER 13 , ROCKERY. E3; FIRE ALARM OF USE. BUSINESS OR ACTFVrM,E,XPLAIN:' cc TYP OVWTRUCTION,� 60 OCCUPANI GROUP P '73 NUMBER NUMBER.OF CRITICAL F-- 0 OF STORIES DWELLING UNITS AREAS NUMBER SPECIAL INS ON JAREA... REQUIRED OCCUPANT LOAD DESCRIBE WORK TO BE DONE S REMARKS z Lf PROGRESS INSPEC71ONS PER U BC 108 ISCI 091 IRCI 09 Fl NAL IN SPECI %1j' ST7 R� W /q V IF 1C, py— I LA S3 #0 VALUATION A 4 z Fbu Nb 5� $ L_C>W,z_y- I OLI io-'� Description t,,QE E Description FEE Wr Ct CV_1_ a�; cz:i, N?1�11V , OINI. Plan (�heF� 11 k State Surcharge HEAr SOURCE' GLAZING % f 0 � r . - - LOT/ % Al Buildin P City Surcharge jjPE 14 a ,&rM,t Z6_ PLAN CHECK NO- VESTED DAlt -0 4 ,Plumbi'n§ Base Fee z: aC2 THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK To Mechanical 1: IIE BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN Grading 71,� (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMITAPPLICATION: Engr. Review ISO DAYS PERMIT LIMIT I YEAR - PROVIDED WORK IS STARTED WITHIN 160 DAYS Engr. Inspection SEE BACK OF PINK PERMIT FOR MORE INFORMATION *APPLICAW ON BEHALF OF HIS OR HER SPOUSE, HEIRS, ASSIGNS AND SUCCESORS Fire Review Plan Chk. Deposit IN INTEREST, AGREES TO INDEMNIFY, DEFEND AND HOLD HARMLESS THE CITY OF EDMONDS, WASHINGTON, ITS OFFICIALS, EMPLOYEES, AND AGENTS FROM ANY AND Fire Inspection Receipt # ALL CLAIMS FOR DAMAGES OF WHATEVER NATURE, ARISING DIRECTLY OR INDIRECTLY FROM THE ISSUANCE OF THIS PERMIT. ISSUANCE OF THIS PERMIT SHALL NOT BE DEEMED TO MODIFY; WAIVE OR REDUCE ANY REQUIREMENT OF ANY CITY ORDINANCE Landscapelnsp. Total Amt. Due 0 NOR LIMIT IN ANY WAY THE C17YS ABILITY TO ENFORCE ANY ORDINANCE PROVISION., Recording Fee i Receipt # I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION; THAT THE INFORMATION GIVEN IS CORRECT, AND THAT I AM THE OWNER, OR THE DULY AUTHORIZED AGENT OF APPLICATION APPROVAL THE OWNER. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUC- TION; AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED CALL This application Is not a permit unit I signed by the IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO FOR INSPECTION Building Official or his/her Deputy: and Fees are paid, and receipt Is acknowledged in space provided. WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. DATE SIGNED (425) �o FI S SIGNA RE DATE EaWk LCR,1_4 �10 771-0220 -e - R ABED B DAtE ATTMT-IbN Off 1333 IT IS UNLAWFULTO USE OR OCCUPYA BUILDING OR STRUCTURE UNTILAFINAL INSPECTION HAS BEEN MADE AND APPROVAL ORA CERTIFICATE OF OCCU- PANCY HAS BEEN GRANTED. UBC109/IBC110/IRC110. ORIGINAL - FILE YEIIC OR 09/03 r%r%Mt%t% 11-111 A r%r% %fd%l I A r%r-- 02 A 1.r1lL40% A PINK -OWNER GOLD -ASSESSOR to— rag;,, V_ j7-w- 06 W�W AW C A' f'7 jSAjW-AM- f.. 11 !, I I \ zr 4M�C4, mf 'Nv­j-,­,,j,,­_ N., 145' If Ira ZV ZSOV,67 R_V.7 j14 I;r 5�7,w f Z ss IW ar jq aor C)7? -v -wofWMER 02\ culrow NX� "IvINV. Ip .- 4E A"A"C' 41, kh ffX`, A A WALL- f4, T 04( .00, 4,9Cl2 V lal AA. 7 BY5 SF N rrj 0 X Cc tz Aill N I mt 7-M .14 A2 AV 41 44, 0. IEKS' 4' n. AA_ iR \401 /717 ft 90 P�R OAD 05 tz I I 113, . — 7; — '20 BLI TILI T 2/ ILI 9 5' ACCE8S SEM L ------- L E'M5W ON I v 4015 dF7 MW A' I I jL' __ "I crw,^ s 09 DWY -eD=- JON V --EAS�_MENT�LOT! L 155 STCWA( Mw� 8&9 14 111 t j96 fe ;4 A r j, -SF L — v 5.402 4 1 20 ri I I --- q I_OSSVW�� AMU 53 s ----I v 4w-a90-6V4f_ ....... j4,,ob9 SF LI 5'-UV/rAflr 4� 1& BSBL /jp M� P/ 'D VlY _U 4' 19/ 79 C)?? ovvz 5 SIE NT 00 SF 7 1703 1 5- \42�\ 37 L-4 SCAPE 1 5 49'SrCWAI 9,941N,4ar L FFER > I Z 00 _/ P(// 3 tF p, /7� u -7 00 OP6ZEd 111�tld!Ml_ 17 1p, 101RIVI, Ye /FR Az,/ / / ex v 6,429 SF 6,858 SF\ J00 00' �R FV*AU E� PAS 45' T4 SEA 0/00,0 N :7 7'� 141 00Z. 47 )00 OVARZCS & P4M ?r5.699 sk, lZjF 00-7480-000-WS-oo PARCa es wy MY7 lwzj v N 117�j4Z4.? sw AS I)pep y 'IF--74 -cap S 48\S J-r4f .95 1lq CMIC N, oll INZ 77, R-M 4,043 SF 4,77-r SF WATER &SEWER INSPECTIONS REQ'D. CAU 42.5-771-02..20 EXT. 1326 MAINTAI I N PLAT INSTALLED EROSION CONTROL. Al.L EXPOSED SURFACES BE COVERED WITHIN 2 C . j5jft()vTl0A/ j�fAVWZSV (0AY-4/1 64,TWAJt6' I o,i,f f OWNERICONTRACTOR IS RESPON CON!T-"n FOR EROSION AND DAIi A5 0 10' UTI L I TY EA5EMENT 51 z r F;FVcor A7 $Vr'r04ll OF (-O-r 0. 13 "., ca fyov 67 .1 P15.43' lb(N bpOe LE(�AL SITE AREA: 7 ) ZONINC7: 0 XXXX PIONEER NAY LOT 15, MADRONA COVE 5,566 SOUARE FEET PLANNED UNIT OEVELOPMENT HE16,HT CALCULATION (BASE0 FROM EXISTINO ORAOE) A= 353' E3= 560' C= 560, 0) = 555, 88.89 0# 7 oo qAfZ05 -TO N 89056'23" E $6'r-(Un OA) 51-Ce, ACCEPTABLE TIGHTLINE fowc,v -3&0 1 MATERIAL APPROVED AS NOTED 012 5 10 15 20 50 VA56y �')fp SDR 35 QF-:l �__] �__=l Z��n BY ENGIPERING u _j SCH-40 a 2MIA"i 1� N - 12 - --------- L07 I e) F81 0 HANCOR Vate: CAVOI ENEERAL NOTEE-5 5EE r--.,E= Zone tas Comer t,' Fla_gj e �tbacks �uimd Actual Front Sides Rear Other Height q3, p,, Sr -,ALE-: ["=20' - —FOOTING DRAINS NOT TO BE TIED INTO P45Heo Lfovtr DETENTION SYSTEM /&&CATC5 We$&A/T emvv6 6a4v6 REcE:IVEED $M��T'FILE . DEC - 6 2004 LANNING PERMIT COUNTER (;2/, 142&/4= 55-7-00' AVER_A(�E EXISTIN(� C-RADE= 55-7x:::)O' ACTUAL BUILDIN(� HEI(:3HT= E352.24' MAXIMUM BUILDIN6, HEIr:-,,HT (25') 7' FROM VARIANCE #V-05-104= 552.70' SURVE'l"OR TO PROVIDE BENGHMARK MOST APROPRIATE FOR HEIC5,HT NVERIFICATION) IMPERVIOUS AREAS f;-,-'E!511:;)ENr,E �^V 1662 5aUARE FEET C-,VF;Z0 PORCHES 1:;>f:P_IVENA'T'5 556 5OUARE FEET PATIO 120 501JARE FEET NALKNA"r5, 100 5aUARE FEET TOTAL 2,455 5OUARE FEET LOT C_,OVERAC-_,E (.LOT COVERA66E IS EASED UPON 55%' OF ENTIRE PLAt�NED UNIT DEVELOPMENT) 1662 5OUARE FEET OF PROP05EI:;) LOT COVERAOE (INCLUDES e)TfPUr-,TUfP-E, COVERED PORCHES, I:;>Er--,<S OVER 50", 05&'e 967T,4(& 01V 4-/ FefZ &-k-r6a(012- Sr,411ew-4 MAI aTREE! FILE', RE:CEIVEr) QkC - 6 2004 PE�MIT COUNTER 0 0.