21401 72ND AVE W.PDFiiiiiiiiii lill
15664
21401 72ND AVE W
of EDAf
A
CITY OF EDMONDS
PHONE: (425) 77.1-0220 - FAX: (425) 771-0221
1215TH AVENUE NORTH -EDMONDS, WA 98020
Parcel No: 00580700002208
PROPERTY OWNER APPLICANT COII'I'AAC'I'*A
PREMIER ORTHb IC GROUP - EDMONDS FIRST WESTERN DEVELOPMENT SRVS. PENNON CONSTRUCTION CO INC
MEDICAL SCOTTSHANKS 5303 1 St Ave South Ste 100
8129 LAKE BALLINGER WAY 8129 LAKE BALLINGER WAY Seattle, WA 98108
EDMONDS, WA 98026 EDMONDS, WA 98026
(425) 329-0848 (425) 329-0848 (206) 418-0235
LICENSE#: PENNOCC013Q3 EXP:6/3/2012
.1110,13 DESCYIPTION
TENANT IMPROVEMENT FOR A MEDICAL CLINIC. WORK WILL INCLUDE EXAM ROOMS, BUSINESS AREAS, THREE
OPERATING ROOMS, MRI, PHYSICAL THERAPY, AND WAITING AREAS. MECHANICAL AND PLUMBING INCLUDED.
VALUATION: $748,821.44
PERMIT TYPE: Commercial
PERMIT GROUP: 71 - Tenant Improvement
GRADING: N CYDS: 0.
TYPE OF CONSTRUCTION: II-B
RETAINING WALL ROCKERY: N
OCCUPANT GROUP: B
OCCUPANT LOAD: 286
NA no
FENCE: N ( 0 X 0 Fr.)
CODE: 09 Am 0 sm I
OTHER: N -----OTHER DESC:
ZONE: CG 2
I NUMBER OF STORJES: 0
VESTED DATE
NUMBER OF DWELLING UNITS: 0
AREA
EXISTING AREA
BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0
PROPOSED
1 BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0
13RD FLOOR: 26146 GARAGE: 0 DECK: 0 OTHER: 0
13R.D FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0
FRONTSETBACK SIDE SETBACK REARSETBACK
REQUIRED: See Below PROPOSED: QUIRED: PROPOSED: �R�EUIRED: PROPOSED:
HEIGHT ALLOWED:0 PROPOSED:O REQUIRED: PROPOSED: ' I
SETBACK NOTES: Tenant improvement for interior changes only, so no change proposed to setbacks and height approved under BLD20110815.
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,'NO
PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF T14E STATE OF WASHINGTON RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18:27.
THIS AULICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HISIHER DEPUTY4NDNLL FEES ARE PAID.
I � # j , -ow V� I P '0
inature Print Name Date
Released By
— z I'/ _�
ATTENTION
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF
OCCUPANCY HAS BEEN GRANTED. UBC 109/ IBC 110/ IRC I 10.
ONLINE APPLICANT ASSESSOR OTHER
STATUS: ISSUED BLD20110816
CONDITIONS
• If visible from 72nd Ave. W,-the rooftop equipment shall be screened from view or painted to match the building in a color
approved by the Planning Division.
• Final Locations of illuminated exit signs & emergency lighting subject to field inspection by the Building Inspector and Fire
Marshal.
• Separate Permit Required For: Shell and Core permit 2011-0815. See separate permits listed under shell permit.
• Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of
the building or structure. Check thdjob card for all required City inspections including final project approval and final
occupancy inspections.
• Any request for altemate design, modification, variance or other administrative deviation (hereinafter "variance") from
adopted codes, ordinances or policies must be specifically requested.in writing and be called out and identified. Processing
fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable.
Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been
specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision
of city code or state law does not approve any items not to code specification.'
Pursuant to UPC 668 a pressure regulator valve (PRV) shall be installed near the water shutoff.
e Sound/Noise . originating from temporary construction sites as a result of construction activity are exempt from the noise limits
of ECC Chapter 5.30 only during the hours of 7:00am to 6:00prn on weekdays and 10:00arn and 6:00pm on Saturdays,
excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must
comply with the noise limits of Chapter 5.30, unless a variance has. been granted pursuant to ECC 5.30.120.
• Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold
harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of
whatever nature, arising directly or indirectly from the issuance for this pen -nit. Issuance of this permit shall not be deemed to
modify, waive or reduce any requirements of any City ordinance nor limit in any way the City s ability to enforce any
ordinance provision.
• Installation, use and maintenance of equipment and components shall be per manufacturer's specifications, installation
instructions, and applicable state codes. Provide manufacture's installation instructions on site for Building Inspector.
I INSPECTIONS
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE
PUBLIC DOMAIN (CURBS, SIDEWALKS. DRIVEWAYS. MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION.
PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6)
I BUILDING (425) 77.1-0220 EXT. 1333 1 ENGINEERING (425) 771-0220 EXT. 1326 1 FIRE (425) 775-7720 1
PUBLIC WORKS (425) 71-0235 PRE-TREATMENT (425) 672-5755 RECYCLING (425) 275-4801
When calling for an inspection please leave'the following information: Permit Number, Job Site Address, Type of Inspection
being requested, Contact Name and Phone Number, Date Prefereed, and whether you prefer morning or afternoon.
B-Plumb Ground Work
B-Plumb Rough In
• B-Gas Test/Pipe
• B-Mechanical Rough In
• B-Curb Attachments
• B-Duct Seal
0 B-Refrigeration Lines
B-Hydronics
B-Ceiling Grid
B-Fire Stopping
B-Framing
B-Sheetrock Nail
B-Plumbing Final
• B-Mechanical Final
• B-Building Final
• F-Fire Safety and Evacuation Plan
• F-Fire Final
P-Planning Final
DEPARTMENT OF BUILDINGS
Adkh� A1Il116.Akkj1kL
PER International Building Code Section
ji
nd
At: 21401 72 Ave W. Edmonds Building.Permit;#:' BLD20110815 & BLD20110816
Occupancy established by this Certificate: Dwelling Units: N/A
B/S 1/S-2
Construction: 11-B
Maximum1,,OccUi3a6t'1bbAd,
ker G 1004)
No. Stories: 3
Basement: No
4A ALLC ""'-'81A"�,ak0 a
Building Owner: Edmonds Medical Bidd'. ss5dd- I "OF Whe Vr- AM � F'e' 9 i.t L lb"'llinger Way, Edmonds, WA 98026
'y
THE Premier Orthopedic Group HAV-�16ELN�'INS�,OtCTEDIVAA'KN'rD'*;A��P�PgR.'�OWVED�eA�',�&CikP . ING WITH THE REQUIREMENTS.OF THE 2009
EDITION OF THE INTERNATIONAL BUII-DING6�6ii�g�rA-�ADOO�Et*D-"'B-Y--�.'T�,H..-.E'�C�';I:.�'T,��'Y.-'�,'F"-0'.R�.�f,'TH'.-F-,'-.G-ROIIP AND DIVISION OF OCCUPANCYAND THE USE
FOR WHICH THE PROPOSED OCCUPANCY IS de-ASSIF,11). -o
'MR
t , h
Issued this 4-dAV-0--filied r.42012
t I ,
7
CHIEF BUILDING OFFICIAL
BY:
This certificate shall be posted In a conspicuous public area and shall not be removed, mutilved or o red and shall be maintained In legible condition at all times. Any change of occupancy or use requires a building permit and a new
Certificate of Occupancy Issued by the City of Edmonds Building Official.
00,
(b rb (b (b (b (b (b d) (b 11) (b (b (b (b (b (b dNIi (h (h (b (h (b (h (h (b (b (h (h f1h 11) V th (b
dF
C
POLLAPM
cum% �
11
0
JAI
�O'
j4-C ZONING CG2
ale
'a Ic TACK IN
rplap. LSO . 4* PLUrj
Mil —F'"N '8848'25" W 'T' I
NW PARCEL Q
3400 GQ4rr (V*UD
ZCHN& ow
0
0
N88 44'1 5"W
1'4.45'
/Z
z V/
9040"
@moo
N 88'48'25" W
324.00'
304,00'
4'
20' PARCEL-FU'Br PARCEL 5
CON\?EYED FROM
JA.ICEW, TO PARCEL C
%, a.
0)
0)
+69'
NEW LOT
LINE
wo ixnmxxw 1PRE11O
Cum "r. STAND
Md" 00""
B.190M
VA.M
231.57' 55.15-
N 88*44'15" IN 251.57'
ELECTRICAL DIST.
EASEMENT A.F. NO.
2294928
q�
v V�3
ZONING CG2 AP ROVED BY LANNING
Comer
Zone—CGr _Nq Fla 6 1koirls JpQ,-
Setbacks Required Act I -";�r
Front
Sides Ato r-h-
_6=,
Rear 0z--v%94i 14
Q)REFERENCE SITE PLAN
Other 2�� N-Qo,r-oved Ltmd;�70
-- 6F%-fm000m-'M +
Heig060 0 w
ht ps:E:mA-
% R EF C E 9 V' E 0
CITY Go
SEP 26 20ii
DEVELOPMENITSERVICES CTR-
CITY-OF EDMONDS
01F EQ4f
Inspection. Comments
BLD20110816 71 - Tenant Improvement
Applied: 09/26/2011 Issued: 01/12/2012
Expires:
01/12/2013
Address: 21401 72ND AVE W, EDMONDS
INSPECTION P 0
1120 - B-'Plumb Ground iv-�ik- 02/13/2012
LAW- ER
PAR
Comment: Groundwork east trench gridlines 3-(10') past 6
1120 - B-Plumb Ground Work 02/15/2012
LAWLER
PAR
Comment: West trench GL 3-12'past 6
1120 - B-Plumb Ground Work 02/21/2012
LAWLER
PAR
Comment: DWV line 71 C to G
1120 -� B-Plumb Ground Work 02/24/2012
LAWLER
COM
Comment: Oil/Water separator
1120 - B-Plumb Ground Work 02/29/2012
LAWLER
PAR
Comment: Partial to sprinkler riser room
1120 - B-Plumb Ground Work 08/15/2012
LAWLER
CIVIP
Comment:
1124 - B-Refrigeration Line Test 11/08/2012
LAWLER
CIVIP
Comment:
1126 - B-Plumb Rough In 12/1312011
MCCONNELL
Com
Comment: Inspection includes floor drains with oil/water separator and connection
to sanitary sewer..
1126 - B-Plumb Rough In 07/1312012
LAWLER
PAR
Comment: Zone 1 and rooms 326,7,8
1126 - B-Plumb Rough In 07/26/2012
LAWLER
PAR
Comment: PT zone level 2 and 3
1126 - B-Plumb Rough In 08/13/2012
LAWLER
COM
Comment: All DWV and water for level III, except recovery and OR zone
1126 - B-Plumb Rough In 10/3V2012
LAWLER
CIVIP
Comment:
1128 - B-Gas Test/Pipe 08/23/2012
LAWLER
PAR
Comment:. Both gas and diesel lines
1128 - B-Gas Test/Pipe 08/29/2012
LAWLER
PAR
Comment: N.20 and 02 at 150 psi, vacuum at 60 psi
1128 - B-Gas Test/Pipe 08/30/2012
LAWLER
CIVIP
Comment: All med gas, vacuum, and air held test
1128 - B-Gas Test/Pipe 10/31/2012
LAWLER
CMP
Comment:
1130 - B-Me.chanical Rough In 06/29/2012
LAWLER
PAR
Comment: RTU 1 curb attachment per Drawing A-27033-5-1
12/7/2012 9:22:47 AM 121 5th Ave, Edmonds Washington - Phone: (425) 771-0220
Page 1 of 4
f RN §P"ERCY 1 '0 _N: -
1130 - B-Mechanical Rough In
10/31/2012
LAWLER
CIVIP
Comment:
1132 - B-Curb Attachments
10/31/2012
LAW LER
CIVIP
Comment:
1133 - B-Duct Seal
07/11/2012
LAWLER
PAR
Comment: -Zone 1 exam area
1133 - B-Duct Seal
08101/2012
LAWLER
PAR
Comment: OR area
1133 - B-Duct Seal
08/10/2012
LAWLER
PAR
Comment: Stair three duct insulation
1133 - B-Duct Seal
08/23/2012
LAWLER
PAR
Comment: OR HEPA ductwork
1133 - B-Duct Seal
10/31/2012
LAWLER
CIVIP
Comment:
1134 - B-Refrigeration Lines
08/14/2012
LAWLER
PAR
Comment: Split system at Second level server room
1134 - B-Refrigeration Lines
10/31/2012
LAWLER
CmP.
Comment:
1136 - B-Hydronics*
08/13/2012
LAWLER
PAR
Comment: Level 111, chiller I
1136 - B-Hydronics
10/31/2012
LAWLER
CIVIP
comment:
1138 - B-Ceiling Grid
09/04/2012
LAWLER
COR
Comment: Install perimeter wires at all walls, and slack
wires on electrical fixtures
11318 - B-Ceiling Grid
09/06/2012
LAWLER
COR
Comment: Perimeter wires to structure, not just drywall
1138 - B-Ceiling Grid
09/07/2012
LAWLER
PAR
Comment: Exam zone
1138 - B-Ceiling Grid
09/19/2012
LAWLER
PAR
Comment: PT, lobby, and Entry. Interior furring framing
at MRI room.
1138 - B-Ceiling Grid
09126/2012
LAWLER
PAR
Comment: Clerestory and stair 1
1138 - B-Ceiling Grid
09/28/2012
LAWLER
PAR
Comment: Stair one entry complete
1138 - B-Ceiling Grid
10/05/2012
LAWLER
COR
Comment: Missing perimeter wires multiple locations
1138 - B-Ceiling Grid
10/09/2012
LAWLER
PAR
Comment: All except third floor lobby and parking level
12/7/2012 9:22:47 AM 121 5th Ave, Edmonds Washington - Phone: (425) 771-022Q
Page 2 of 4
lN, S P F, 0—IN
1138 -.13-Ceiling Grid
10/30/2012
LAWLER
PAR
Comment: Third floor lobby 4x4 grid
1138 - B-Celling Grid
11/08/2012
LAWLER
PAR
Comment: parking strucure
1138 -* B-Ceiling Grid
11/16/2012
LAWLER
CIVIP
Comment: MRI
1141 - B-Fire Stopping
09/27/2012
LAWLER
PAR
Comment: Dropped off maintainable bond requirements. from Marie.
1141.- B-Fire Stopping
10/3i/2012
LAWLER
CIVIP
Comment:
1142 - B-Framing
07/09/2012
LAWLER
PAR
Comment: Dropped off approved fueling station plans. Generator SOG
approved pending special
inspectiom
1142 - B-Framing
07/16/2012
LAWLER
COR
Comment: 1.) fireblock stud cavities with rigid insulation
2.) install top of wall bracing at 8'oc intervals max spacing
1142 - B-Framing
07/19/2012
LAWLER
COR
Comment: Complete fire blocking with no air spaces
1142 - B-Framing
07/20/2012
LAWLER
PAR
Comment: Exam Zone
1142 - B-Framing
07/30/2012
LAWLER
PAR
Comment: PT/Iobby zone cover
1142 - B-Framing
08/2912012
LAWLER
PAR
Comment: One hour wall firestopping behind furred wall at GL31
1142 - B-Framing
10/31/2012
LAWLER
CIVIP
Comment:
1150 - B-Sheetrock Nail
07/24/2012
LAWLER
PAR
Comment: Exam rooms
1150 - B-Sheetrock Nail
07126/2012
LAWLER
PAR
Comment: completion of exam zone
1150 - B-Sheetrock Nail
08/15/2012
LAWLER
PAR
Comment: Lead shielding at X-ray room
.1150 - B-Sheetrock Nail
08/17/2012
LAWLER
PAR
Comment: Level* III ACC restroom area
1150 - B-Sheetrock Nail
09/18/2012
MILLERC
PAR .
Comment: Observed GWB attachment - Stair 1 - ok to cover tape mud - verified fuel station enclosure
construction
1150 - B-Sheetrock Nail
10/31/2012
LAWLER
CIVIP
Comment:
12/7/2012 9:22:47 AM 121 5th Ave, Edmonds Washington - Phone: (425) 771-0220 Page 3 of 4
0 . . 0
'7�sp:'gc
�IqWKIQIV Ali
1152 - B-Plumbing Final
11/08/2012
LAWLER
COR
Comment: 1.) Install RPBA at ice maker
2.) Complete sink installations
3.) Listing for solids trap
1162 - B-Plumbing Final
1.1/26/2012
LAWLER
CMP
Comment:
1156 - B-Mechanidal Final
11/14/2012
LAWLER
PAR
Comment: Just an observation
1156 - B-Mechanical Final
11/26/2012
LAWLER
CMP
Comment:
1158 - B-Building Final
12/0312012
LAWLER
COR
Comment: See correction notice
1158 - B-Building Final
12/04/2012
LAWLER
CMP
Comment:
1950 - F-Fire Safety and Evacuation Plan
12/03/2012
SMITHM
CMP
Comment: APPROVED
1985 - F-Fire Final
12/03/2012
SMITHM
CMP
Comment: APPROVED
2000 - P-Planning Final
12/03/2012
MACHUGA
CMP
Comment: All exterior improvements done under Permit No. BLD20110815.
No Planning inspection necessary for
the interior improvements under this permit.
Planning Division signs off 12/3/12.
12/7/2012 9:22:47 AM 121 5th Ave, Edmonds Washington - Phone: (425) 771-0220 . Page 4 of 4
f
4 of ED4 0 -P CITY OF . EDMONDS
121 5TH AVENUE NORTH - EDMONDS, WA 98020
PHONE: (425) 771-0220 - FAX: (425) 771-0221
4""':l So
Expiration Date: 4/9/2013
Parcel No: 00580700002208
PROPERTYOWNER APPLICANT CONTRACTOR
PREMIER ORTHOPEDIC GROUP - EDMONDS PATRIOT FIRE PROTECTION INC PATRIOT FIRE PROTECTINTNC
MEDICAL 2707 70Th Ave E 2707 70Th Ave E
PO BOX 27165 Tacoma, WA 98424 Tacoma, WA 98424
SEATTLE, INA 98125
(253) 926-2290 (253) 926-2290
LICENSE #: PATRIFP099CF EXP: 10/5/2012
JOB DESCRIPTION
NEW FIRE SPRINKLER SYSTEM.
VALUATION: $96,000.00
PERMIT TYPE: Commercial PERM IT GROUP 1 :30 - Fire Sprinkle, CtAj0'MMPL'ETFu
GRADING: N CYDS: 0
TYPE OF CONSTRUCTION:
RETAINING WALL ROCKERY: N
OCCUPANT GROUP:
OCCUPANT LOAD:
FENCE: N 0 X 0 Fr.)
CODE: 09
OTHER: N ---OTHER DESC:
IZONE:
NUMBER OF STORIES: 0
1 VESTED DATE:
INUMBER OF DWELLING UNITS: 0
LOT #:
EXISTING AREA
BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0
PROPOSED A14EA
��EMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0
13RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0
13RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0
FRONT SETBACK SIDE SETBACK REAR SETBACK
REQUIRED: PROPOSED: IREQUIR-ED: PROPOSED: �RE ULRED� PROPOSED:
HEIGHT ALLOWED:O PROPOSED:O I REQUIRED: PROPOSED:
SETBACK NOTES:
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO
PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18:27. -
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES AR.E PAID.
bvIi& aW� sWilviu fakrfo L4 I :-f I ) -2 �&)* 11-,-�;-102
Print Name
Released By
ATTENTION
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CER11FICATE OF
OCCUPANCY HAS BEEN GRANTED. UBC 109/ IBCI 10/ IRCI 10.
fligiiw
ONLINE APPLICANT ASSESSOR OTHER
STATUS: ISSUED BLD20120162
CONDITIONS
• Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of
the building or structure. Check the job card for all required City inspections including final project approval and final
occupancy inspections.
• Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from
adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing
fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable.
Approval of any plat or plan containing provi sions which do not comply with city code and for which a variance has not been
specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision
of city code or state law does not approve any items not to code specification.
Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits
of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays,
excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must
comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold
harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages,of
whatever nature, arising directly or,indirectly from the issuance for this permit. Issuance of this permit shall not be deemed to
modify, waive or reduce any requirements of any City ordinance nor limit in any way the City s ability to enforce any
ordinance provision.
I INSPECTIONS
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE
PUBLIC DOMAIN (CURBS. SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. .
PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6)
BUILDING (425) 771-0220 EXT. 1333 1 ENGINEERING (425) 771-0220 EXT. 1326 1 FIRE (425) 775-7720
PUBLIC WORKS (425).771-0235 PRE-TREATMENT (425) 672-5755 RECYCLING (425) 275-4801
When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection
being requested, Contact Name and Phone Number, Date Prefereed, and whether vou prefer mornine or afternoon.
• F-Fire Connection Installation
• F-Fire Sprinkler Acceptance
0 Inspection Comments
81-1320120162 30 - Fire Sprinkler.
Applied: 03/12/2012 Issued.: 04/69/2012
Address: 21401 72ND AVE W, EDMONDS
NSPEC'
NSPECTION
-DATE
1905 - F-Fire Connection Installation 07/16/2012 SMITHM
Comment: Valve Cluster, Pipe, Restraints, Thrust Blocks and Bedding Approved
1905 - F-Fire Connection Installation 07/19/2012 SMITHM
Comment: Hydro and Flush Approved
1930 - F-Fire Sprinkler Acceptance 07/16/2012 SMITHM
Comment: Hydro, Spacing, Bracing and Head location Approved
1930 - F-Fire Sprinkler Acceptance 12/03/2012 SMITHM
Comment: System Tested and Accepted
I
Expires: 04/09/2013
011 1
PAR
CMP
PAR
CMP
12/7/2012 9:20:13 AM 121 5th Ave, Edmonds Washington - Phone: (425) 771-0220 Page 1 of 1
of ED4f
CITY OF EDMONDS
PHONE: (425) 771-0220 - FAX: (425) 771-0221
121 5TH AVENUE NORTH - EDMONDS, WA 98020
STATUS: ISSUED 1/27/2012
Expiration Date:'7/27/2012
Parcel No: 00580700002208
PROPE&TV *WNER APPLICA71T C*N'I'&AC'VOR
PREmlER oRTHopEbic GROUP - EDMONDS PACIFIC FIRE AND -SECURITY INC PACIFIC FIRE AND SECURITY INC
MEDICAL BAKER, JON T BAKER, JON T
PO BOX 27165 828 Poplar I'l S 828 Poplar PI S
SEATTLE, WA 98125 Seattle, WA 98144 Seattle, WA 98144
(206) 957-0907 (206) 957-0907
LICENSE #: PACIFFS914MF EXP:7/l/2013
JOB DESCRIPTION
FIRE ALARM SYSTEM FOR NEW ORTHOPEDIC CLINIC.
VALUATION: $0.00
PERMIT TYPE: Commercial
PERMIT GROUP: 79 - Fire Alarm 21
GRADING: N CYDS: 0
TYPE OF CONSTRUCTION:
RETAINING WALL ROCKERY: N
OCCUPANT GROUP:
OCCUPANT LOAD:
FENCE: N ( 0 X 0 Fr.)
CODE: 09
OTHER: N ----OTHER DESC:
ZONE:
I NUMBER OF STORIES: 0
1 VESTED DATE:
I NUMBER OF -DWELLING UNITS: 0
LOT #:
EXISTING AREA
I BASEMENT: 0 1 T FLOOR: 0 2ND FLOOR: 0 ��BASEMENT:
PROPOSED AREA
0 1 ST FLOOR: 0 2ND FLOOR: 0
13RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0
13RD FLOOR: 0 —GARAGE. 0 DECK: 0 OTHER: 0
FRONTSETBACK SIDE SETBACK REAR SETBACK
REQUIRED: PROPOSED: ��KEQUIR.ED: PROPOSED: I REQUIRED: PROPOSED:
HEIGHT ALLOWED:O PROPOSED:O IREQUIRED: PROPOSED:
SETBACK NOTES:
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO
PERSON WILL BE EMPLOYED IN VIOLATION,OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18:27.
IS APPLICATION IS NOT XIPERmrr UNTIL SIGNED BY THE BUILDING OFFICIAL OR HISfHER DEPUTY ANLE�J, FEES ARE PAID,
t2Cftv1few11vtr.7'f e2-M / �_'— Z,'2--
Siboalluk j Print Name/ I Date Released By - Date
v . ATTENTION 0
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF
OCCUPANCY HAS BEEN GRANTED. UBC 109/ IBC 110/ IRC 110.
= ONLINE = APPLICANT = ASSESSOR FM OTHER
0
0
STATUS: ISSUED
BLD20110856
• Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of
the building or structure. Check thejob card for all required City inspections.including final project approval and final
occupancy inspections.
• Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from
adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing
fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable.
Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been
specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision
of city code or state law does not approve any items not to code specification.
Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from thenoise limits
of ECC Chapter 5.30 only during the hours of 7:00arn to 6:00prn on weekdays and 10:00am and 6:00prn on Saturdays,
excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must
comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold
harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of
whatever nature, arising directly or indirectly from the issuance for this permit. Issuance of this permit shall not be deemed to
modify, waive or reduce any requirements of any. City ordinance nor limit in any way the City s ability to enforce any
ordinance provision.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO 13E DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE
PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEESi ETC.) WILL REQUIRE SEPARATE PERMISSION.
PERMIT TIME,LIMIT: SEE ECDC 19.00.005(A)(6)
I BUILDING (425) 771-0220 EXT. 1333 1 ENGINEERING (425) 771-0220 EXT. 1326 1 FIRE (425) 775-7720 1
I PUBLIC WORKS (425) 771-0235 1 PRE-TREATMENT (425) 672-5755 1 RECYCLING (425) 275-4801
When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection
being reauested, Contact Name and Phone Number, Date Prefereed, and whether vou Prefer morning or afternoon.
0 F-Fire Alarm System Acceptance
0,F ED
Al
Inspection Comments
BLD20110856 79 - Fire Alarm
Appliedt 10/11/2011 Issued: 01/27/2012 Expires: 07/27/2012
Address: 21401 72ND AVE W, EDMONDS
..,DATE ECT R-
1935 F-Fire Alarm System Acceptance 12/03/2012 SMITHM CMP
Comment: APPROVED
0
12/7/2012 9:21:50 AM 121 5th Ave, Edmonds Washington - Phone: (425) 771-0220 Page 1 of 1
Of FD-4 0
CITY OF EDMONDS
121 5TH AVENUE NORTH - EDMONDS, WA 98020
/" 4C.011 PHONE: (425) 771-0220 - FAX: (425) 771-0221
. I zgz
Expiration Date:
Parcel No: 00580700002208
PE ATV *W 1 E R APPLICA1'11' COITRACTOR
EDMONDS MEDICAL BLDG. ASSOC. LLC DDG ARCHITECTS PENNON CONSTRUCTION CO INC
8129 LAKE BALLINGER WAY JIM WIEBEN 5303 1 St Ave South Ste 100
EDMONDS, WA 98026 16398 NE 85TH STREET Seattle, WA 98108
REDMOND, WA 98052
(425) 329-0848 (425) 289-5805 (206) 418-0235
LICENSE #: PENNOCC013Q3 EXP:6/3/2012
,JOB DESCRIPTION
3 STORY BUILDING CONTAINING OFFICES AND TWO FLOORS OF PARKING. SHELL AND CORE PERMIT - INCLUDES
CIVILS.
VALUATION: $7,534,799.56
PERMIT TYPE: Commercial
PERMIT GROUP: 45 - New Commercial
GRADING: N CYDS: 0
TYPE OF CONSTRUCTION: fl-B
RETAINING WALL ROCKERY: N
OCCUPANT GROUP: B/S- I /S-2
OCCUPANT LOAD: see TI
FENCE: N ( OXO Fr.)
CODE: 09
OTHER: N --- OTHER DESC:
ZONE: CG 2
I NUMBER OF STORIES: 3
VESTED DATE:
NUMBER OF �DWELLING �UNFrS: 0
�BA
LOT #:
1 haml N
7SEMENT: 0 1 ST FLOOR! 0 2ND FLOOR: 0 BASEMENT: 0 ISTFLOOR:27358 2ND FLOOR: 27358
IST L
13RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0
13RD FLOOR- 27358 GARAGE: 0 DECK: 0 OTHER: 0
FRONTSETBACK SIDE SETBACK REAR SETBACK
REQUIRED: W = 4' PROPOSED: 4' __+REQUIRED: N = 0' PROPOSED: 0' --F,�IRED: E = 0' . PROPOSED: 0720'
P
HEIGHT ALLOWED:75 PROPOSED:50.87 'EQUIRED: S = 0' PROPOSED: 0'
SETBACK NOTES: No more than 30 inches of eaves may project into 4' street setback.
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO
PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18:27.
IS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY -AND ALI..FEES ARE PAID.
t-1 %�- 1-u— " 12- /14 /2-ar-1 I . V//" 2 64 — /-Z/- &
Signature Print Name Date Released Br Dat6 "
ATTENTION
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF
OCCUPANCY HAS BEEN GRANTED. UBCI 09/ IBC 110/ IRC 110.
= ONLINE = APPLICANT = ASSESSOR
OTHER
? �' �Q��'b\�V
0
STATUS: ISSUED
BLD20110815
• New and existing buildings shall have approved address numbers, building numbers or approved building identification
placed in a position that is plainly visible from the street or road fronting the property. Address numbers shall be Arabic
numerals or alphabet letters. Numbers shall be legible from the public way, at least 6 inches high with a 3/4 inch min. stroke
width on a contrasting background.
• If visible from 72nd Ave. W, rooftop equipment shall be screened from view or painted to match the building in a color
approved by the Planning Division.
• Conditions of approval of the design review decision located in File No. PLN20110063 shall be met.
• Se parate Permit Required For: Tenant Improvements, Plumbing, MechanicaVHVAC, L&I Boiler (for air compressor), L&I
Electrical, Fire Connection Permit, Fire Sprinkler; Fire Alarm, Fire Protection Footprint.
0 REQUIRED SPECIAL INSPECTIONS FOR THIS PROJECT:
0 By the Geotech of Record-
0 1) Excavation, grading, & site preparation
0 2) Soi I bearing verification/ Auger cast piles
0 3) Placement of fill & compaction
0 4) Footing drain
0 5) Temporary Erosion Control
* 6) Final Erosion Control
7) General site monitoring
8) Final letter from geotechnical engineer of record
0 Structural:
0 1) Concrete
0 2) Bolting in concrete
0 3) Post Tension tendons
0 4) Structural Steel including High Strength Bolting and Welding
a 5) Seismic Attachments of mechanical and Electrical Components
0 6) 8 inch Hollow Planks
7) Exterior Cladding
8) Structural Observation by Engineer of Record
Obtain Electrical Permit from State Department of Labor & Industries. 425-290-1309
Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of
the building or structure. Check the job card for all required City inspections including final project approval and final
occupancy inspections.
Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from
adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing
fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable.
Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been
specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision
of city code or state law does not approve any items not to code specification.
Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits
of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays,
excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must
comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold
harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of
whatever nature, arising directly or indirectly from the issuance for this permit. Issuance of this permit shall not be deemed to
modify, waive or reduce any requirements of any City ordinance nor limit in any way the City s ability to enforce any
ordinance provision.
INSPECTIONS
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE
PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION.
PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6)
BUILDING (425) 771-0220 EXT. 1333 ENGINEERING (425) 771-0220 EXT. 1326 -FIRE (425) 775-7720
PUBLIC WORKS (425) 771-0235 PRE-TREATMENT (425) 672-5755 RECYCLING (425) 2,75-4801
When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection
— being requested, Contact Name and Phone Number, Date Prefereed, and whether you prefer morning or afternoon.
• B-Preconstruction meeting
• B-Setbacks
• B-Footings
• B-Foundation Wall
• B-Foundation Drainage
• B-Structural Slab
B-Exterior Wall Sheathing
B-Roof Sheathing
B-Exterior Cladding
B-Fire Stopping
B-Framing
B-Insulation/Energy
B-Sheetrock Nail
B-Building Final
F-Fire Safety and Evacuation Plan
F-Fire Final
P-Planning Final
Inspecti n Comments
0
BLD20110815 45 - New Commercial
Applied: 09/26/2011 Issued: 12/14/2011
Exp 1res:
12/1.4/2012
Address: 21401 72ND AVE W, EDMONDS
DATif
N'*S'""' Tie
PE
1000 E-Pre-Con 12/1,9/2011
MCCONNELL
CMP
Comment: J.Lambert also in attendance. Sign -in sheet noting all others is attached.
1001 - E-Erosion Control/Mobilization 12/22/2011
LAMBERTJ
PAR
Comment: w/J.Zulauf - TESC adequate at this time
1001 - E-Erosion Control/Mobilization. 02107/2012
ZULAUF
COM
Comment: tesc ok
1001,-,E-Erosion Control/Mobilization 11/26/2012
MCCONNELL
CMP
Comment: Project finaled.
1013 - E-Storm Tightline 02/07/2012
ZULAUF
COM
Comment: tightline from building to detention vault. Ok to bury
1013 - E-Storm Tightline 11/26/2012
MCCONNELL
CMP
Comment: Project final approved.
1015 E-Storm Detention System 02/07/2012
ZULAUF
COM
Comment: connection from west side of vault to control m/h, ok to b/f
1015 - E-Storm Detention System 11/26/2012
MCCONNELL
CMP
Comment: Approved for final. Mayes testing reports attached.
1017 - E-Footing Drain Connection
Comment:
1018 - E-011Mater Separator 02/24/2012 MCCONNELL CMP
Comment: Located in Parking garage. P.Lawler confirmed connection to sanitary sewer system. Pictures in
Engineering file.
1037 - E-Remote Reader Installation 09/25/2012 MCMURPHY COM
Comment: Need to install TRPL Sensus remote wall mounted meter on fire line. Drill hole on exterior wall for Wall
mount.
1037 - E-Remote Reader Installation 11/26/2012 MCMURPHY
-CMP
Comment: Approved.
1039 - E-RPBA with HotBox 09/25/2012 MCMURPHY
CIVIP
Comment: Backflow report received and okay.
1051 - E-Pavement Striping 11/26/2012 MCCONNELL
CMP
Comment: Approved.
1075 - E-Trash Enclosure 10/08/2012 MCCONNELL
CMP
Comment: Approved. Enclosure is within building, access from 72nd via alternate drive.
1076 - E-Cross Connection Final 09/25/2012 MCMURPHY
CMP
Comment: Received backfiow reports for fireline, domestic & irrigation systems - approved.
12/7/2012 9:24:45 AM 121 5th Ave, Edmonds Washington - Phone: (425) 771-0220
Page 1 of 5
-.L2
1077 - E-Engineering Final 09/25/2012
MCCONNELL
COM
Comment: Spoke with Jeff, they're not quite ready. He will call back
or email when they are.
1077 - E-Engineering Final 10/08/2012
MCCONNELL
Com
Comment: Need to stripe parking and install remote read on building for fire line meter.
1077 - E-Engineering Final 11/26/2012
MCCONNELL
CIVIP
Comment: Project approved for final.
1101 - B-Preconstruction meeting 12/19/2011
BJORBACK
PAR
Comment: At city hall with Jeff Still, Mac Sele, Scott Shanks, Jim Weiben, Todd Wirtz (Mayes Testing), E3RA
Geotech, Donnybrook Excavating.
City staff: PAt Lawler, Leif Bjorback, Jeanie McConnell, Jennifer
Lambert, Jen Machuga, Mike Smith
1101 - B-Preconstruction meeting 03/27/2012
LAWLER
CIVIP
Comment:
1106 - B-Setbacks 12/03/2012
LAWLER
CIVIP
Comment:
1108 - B-Footings 12/29/2011
LAWLER
PAR
Comment: Just setting up auger, will return tomorrow
1108 - B-Footings 12/30/2011
LAWLER
Com
Comment: Observed sample auger operation, inspected typical cage which conformed with approved plans.
1108 - B-Footings 02/06/2012
LAWLER
PAR
Comment: Gridline 1A-H, A 1-10 and isolated footings in between. Special inspector to verify clearances and
dewatering.
1108 - B-Footings 02/08/2012
LAWLER
Com
Comment: 6 line F-C, E&.D line 6-7.2
1108 - B-Footings 02/10/2012
LAWLER
Com
Comment: D-A on 9,A6.3-9, C&5,7,&8, B-7 (pile caps
1108 - B-Footings 02/16/2012
LAWLER
PAR
Comment: Grade beams at elevator pit
1108 - B-Footings 02/17/2012
LAWLER
CIVIP
Comment:
1110 - B-Foundation Wall 01/13/2012
LAWLER
PAR
Comment: detention facility
1110 - B-Foundation Wall 03102/2012
LAWLER
PAR
Comment: Type A SW grid H
Type Z1 & Z2 SW grid 1
North 1/2 columns
1110 - B-Foundation Wall 03/09/2012
LAWLER
PAR
Comment: Front Type A walls require (4#5 rebars at ends
1110 - B-Foundation Wall 03/1412012
MILLERC
PAR
Comment: SEE ATTACHMENT
1110 - BmFoundation Wall 03/1912012
LAWLER
PAR
Comment: Elevator shaft, sw no. 1, GL A 6.75 to 7.25
12/7/2012 9:24:45 AM 121 5th Ave, Edmonds Washington - Phone: (425) 771-0220
Page 2 of 5
,F,
NSPECT1647-
1110 - B-Fou ndation Wall
04/09/2012
LAWLER
PAR
Comment: See mini's
1110 - B-Fou ndation Wall
04/13/2012
LAWLER
PAR
Comment: North wall and south stair tower
1110 - B-Foundation Wall
04/19/2012
LAWLER
PAR
Comment: Second floor complete pending special inspection approval
1110 - B-Foundation Wall
05110/2012
LAWLER
PAR
Comment; Third floor Walls, see mini's
1110 - B-Foundation Wall
05/15/2012
LAWLER
PAR
Comment: Third floor see on site minis for locations
1110 - B-Fou ndation Wall
05/17/2012
LAWLER
PAR
Comment: Third floor tall walls complete
1110 - B-Fou ndation Wall
05/18/2012
LAWLER
PAR
Comment: CMU first lift un'der-ramp, elevator mechanical room
1110 - B-Foundation Wall
05/23/2012
LAWLER
PAR
Comment: CMU second floor first lift see mini's
1110 - B-Foundation Wall
06/04/2012
LAWLER
PAR
Comment: P-2 Gridline -2
1110 - B-Foundation Wall
06/11/2012
LAWLER
COM
Comment: P-2 car barriers grid lines G and 9
1110 - B-Foundation Wall
10/31/2012
LAWLER
CIVIP
Comment:
1114 - B-PT Slab
03/2912012
LAWLER
PAR
Comment: Grid 5'east of D to H 1-9
1114 - B-PT Slab
04/04/2012
LAWLER
PAR
Comment: Second floor.phase 11 pending special inspection
1114 - B-PT Slab
04/27/2012
LAWLER
COM
Comment: Third floor east deck
1114 - B-PT Slab
05/07/2012
LAWLER
CIVIP
Comment:
1120 - B-Structural Slab
01/11/2012
LAWLER
PAR
Comment: Detention vault SOG and vertical rebars
1120 - B-StrUctural Slab
01/30/2012
LAWLER
PAR
Comment: Detention vault hollow core planking
1120 - B-Structural Slab
02/22/2012
LAWLER
PAR
Comment: 8" and 12" SOG
1120 - B-Structural Slab
03/01/2012
LAWLER
PAR
Comment: all but MRI slab
12/7/2012 9:24:45 AM 121 5th Ave, Edmonds Washington - Phone:
(4125) 771-0220
Page 3 of 5
NNWE�UIOW
. . . . . . . . .
.
1120 - B-Structural Slab
06/27/2012
LAWLER
CIVIP
Comment: MRI okay after Mayes'approval
1124 - B-Exterior Gypsum Sheathing
06/19/2012
LAWLER
PAR
Comment: Grid lines.H,G,&9-G to F
1124 - B-Exterior Gypsum Sheathing
06/21/2012
LAWLER
PAR
Comment: Parapets complete
1124 - B-Exterior Gypsum Sheathing
07/03/2012
LAWLER
PAR
Comment: Penthouse mechanical room
1124 - B-Exterior Gypsum Sheathing
10/31/2012
LAWLER
CIVIP
Comment:
1132 B-Exterlor Wall Sheathing
10/31/2012
LAWLER
CIVIP
Comment:
1133 - B-Roof Sheathing
LAWLER
CIVIP
Comment:
1134 - B-Exterior Cladding
10/31/2012
LAWLER
CIVIP
Comment:
1141 - B-Fire Stopping
08/03/2012
LAWLER
COR
Comment: Failed (again)
1141 - B-Fire Stopping
08/08/2012
LAWLER
PAR
Comment: Slab edge spray applied firestopping material applied
1141 - B-Fire Stopping
08/10/2012
LAWLER
PAR
Comment: Slab edge approved subject to engineering judgement from Hllti
1141 -� B-Fire Stopping
08/13/2012
LAWLER
COR
Comment: Mineral not tightly packed
1141 - B-Fire Stopping
08/14/2012
LAWLER
PAR
Comment: Slab edge complete
1141 - B-Fire Stopping
10/31/2012
LAWLER
CIVIP
Comment:
1142 - B-Framing
06/14/2012
LAWLER
PAR
Comment: Pending RFI 3 Tek screws into 1/4" angle at parapet walls grid lines H and 9
1142 - B-Framing
06/19/2012
LAWLER
PAR
Comment: Grid lines 9 and H from E to 6
1142 - B-Framing
10/31/2012
LAWLER
CIVIP
Comment:
1146 - B-Insulation/Energy
08/01/2012
LAWLER
PAR
Comment: Exterior walls at PT zone
1146 - B-Insulation/Energy
10/31/2012
LAWLER
CIVIP
Comment:
12/7/2012 9:24:45 AM 121 5th Ave, Edmonds Washington - Phone:
(425) 771-0226.
Page 4 of 5
M
JBIA=C-1101
1150 - B-Sheetrock Nail 10/31/2012
LAWLER
CMP
Comment:
1158 -'B-Building Final 11/05/2012
LAWLER
PAR
Comment: Handrail dilemma discussion onsite
1158 - B-Building Final 12/03/2012
LAWLER
COR
Comment: Geotechnical final letter
1158 - B-Building Final 12/04/2012
LAWLER
CMP
Comment:
1905 - Fire Connection Partial 03/09/2012
WESTFALL
CMP
Comment: Inspected connection installation from bottom of riser approximately
10' UG towards
street. Installation
allowed for slab construction in sprinkler room.
1950 - F-Fire Safety and Evacuation Plan 12/03/2012
SMI THM
CMP -
Comment: APPROVED
1985 - F-Fire Final 12/0312012
SMITHM
CMP
Comment: APPROVED
2000 - P-Planning Final 11/28/2012
MACHUGA
CMP
Comment: Landscaping is consistent with approved plans. Landscape maintenance bond was
submitted on
11/27/12. Signed off on 11/28/12.
12/7/2Q1 219:24:45 AM 121 5th Ave, Edmonds Washington - Phone: (425) 771-0220 Page 5 of 5
-E. 1 0 ,
City of Edmonds
DEVELOPMENT SERVICES
COMMERCIAL & MULTI -FAMILY BUILDING
PERMIT APPLICATION
121 5h Avenue N, Edmonds, WA 98020
Phone 425.771.0220 It Fax 425.771.0221
PLEASE REFER TO THE COMMERCL4L & MULTI -FAMILY BUILD17VG CHECKLIST FOR SUBMITTAL REQUIREMENTS
PROJEC ADDRESS (Street, Suit # C State Zip):
-41ol ;7"q
Parcel #:
SubdivisioiijUt #:'
Project Valuation: $
APPLICANT:
Phone:
Fax:
Address (Street, City, State, Zip):
E-Mail Address:
PROPERTY OWNER:
Phone:
Address (Street, City, State, Zip):
E-M�il Address:
LENDING AGENCY:
Phone:
Fax:
Address (Street, City, State, Zip):
E-Mail Address:
CONTRACTOR:*
12L Ct
1+(i 01 r*
0
Phone:
2'5-3 - 'T 77-7 D
Fax:
I 2S3 017-2-- (a I S 0
Address (Street, City, State, Zip):
E-Mail Address
*Contractor must have a valid City ofEdmonds business license prior to
doing work in the City. Contact the City Clerk's. Office at 425.775.2525
W S ense #1AE ' Dat
=1 / _t
City Business Uicense #/Ex�. bate:
DETAIL SCOPE OF WORK:' —
PROPOSED NEW SQUARE FOOTAGE
FOR THIS PROJECT:
Basement: sq. ft.
Garage: —sq, ft,
1 " Floor: sq. ft.
Deck: sq. ft.
2 nd Floor: q. ft.
Other: sq. ft.
7�Floor: sq. ft.
Occupancy: Occupancy Load:
Retaining Wall: 0 Yes 0 No
1 Grading: _____,cyds.
I Type of Construction:
I declare underpenalty ofperjury laws that the information I have provided on thisformlapplication is true, correct and
complete-, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to
the City of J�dmonds.
Print Name: .4 — 0 Owner 0 Agent/Other (specify):
Signature: S-V101 I viol mbrC91 Date:
FOWE LABuilding New Folder 2010\DONE & x-ferred to LBuilding-New drive\Form E.doc Updated: 10/2011
Equipment Type
Appliance/Equipment Information (new and relocated)
Total #
Furnace
#
Gas #—Elec
#—Other:
BTUs: <100k— >100k—
Location
Air Handler/ACNAV
#
Gas #—Elec
#—Other:
CFM: <100k— >100k—
Location
Boiler/Compressor/
Heat Pump/Roof Top
Unit
.#
HP:
Gas #—Eled
<3,
#—Other:
_3-15,
BTUs: <1 00k, _I
15-30 Location
OOk-500k, 500k-lMil
Hydronic Heating
#
Gas #—Elec
—in-Floor,
—Wall Radiant, Boiler BTUs:
Location
Exhaust Fans (single
duct)
Location: #—Bath
#—Kitchen
#—Laundry # _Other:
Fireplace
Gas #—Elec
#—Other:—
Location
Other
Number of Outlets
Fixture/Appliance Type
AC Unit --------------- BTUs: Location:
Furnace --------------- BTUs: Location:
Water Heater -------- BTUs: Location:
Boiler ------------------ BTUs: Location:
Fireplace/Insert BTUs: Location:
Stove/Range/Oven:
Dryer
Outdoor BBQ:
Other:
TOTAL OUTLETS
PLUMBING FIXTURE COUNT
Number
Fixture Type
Number
Fixture Type
Water Closet (Toilet)
Refrigerator water Supply (for water/ice dispenser)'
Sink (kitchen, laundry, lavatory, bar, eye wash, etc.)
Water Service Line
Tub/Shower
Drinking Fountain
Dishwasher
Bidet/Urinal
Hose Bib
Pressure Reduction Valve/Pressure Regulator
Water Heater Tankless? Yes— No—
Backflow Prevention Device (e.g. RBPA, DMA, AVB)
Expansion Tank for Water Heater
Hydronic Heat in: Floor Wall
Floor Drain/Floor Sink
Other:
Clothes Washer
Other:
FORME L:\Building New Folder 2010\DONE & x-ferred to L-Building-New drive\Form E.doc Updated: 10/2011
011., ,-DAfo
C
�o
DEVELOPMENT SERVICES
COMMERCIAL & MULTI -FAMILY BUILDING CHECKLIST
121 5b Avenue N, Edmonds, WA 98020
Phone 425.771.0220 9 Fax 425.771.0221
City of Edmonds
PROJECT ADDRESS:
PRE -APPLICATION MEETING? 0 YES 0 NO If YES, Pre -application Number:
Plans shall be of sufficient clarity to indicate the location, nature, and extent of the work proposed, and conform to the provisions of
the adopted International Code8 and City Ordinances.
r) �0.
= V
W cc
SUBMITTAL REQUIREMENTS
The number indicates the number ofcopiesfor
submittal( ifapplicable). Check marks indicate
additional submittal requirement as applicable
c! 5
W
Z
Oil
0* *�
n
ci
co
Oil III ot
Application Form E
Site Plan
3
3
3
3
3
3 F/C
Reduced Site Plan (I I X 14 or 8 1/2x 11)
1
1
1
1
1
1 F/C
Architectural Construction Drawings
3
3
3
3
3
3
Structural Drawing and Calculations
3
3
3
3
WA State Energy Code NREC Calcs & Lightin 9
%/
Site Classification Worksheet
3
3
Site Development Plans/Civils
4
4
Engineering Report/Drainage Calculations
3
3
Landscape Plan
3
3
Right —of-Way Permit Application
1
1
Critical Areas Determination or Checklist
I
I
Geotechnical Report
3
3
Health District Approval Letter
%/
Manufacturer's Specifications/Cut Sheets
V/
Vol
3
Contracto r's City of Edmonds Business License
V/
V
V
Washington State Contractors License
V/
V,
V11
-v/
Plan Check Fee (due upon submittal)
V/
V
V/
V/
V
Traffic Impact Analysis
3
3
3
3
Survey
3
3
Special Inspection and Testing Agreement
V1,
V/
Envelope Plans and Documents/Condos
2
2
Bonds
1
1
V,
Architectural Design Approval
1
1
V/
Peer Review Fees
V
%/
Deferred Submittals
V/
Shop Drawings
V/
Street Use
• Handouts and Standard Details may be found on the City's webkte www.ci.edmonds.wa.us or can be obtamied at City Hall
during normal business hours.
• Plans/calculation/reports prepared by state licensed architects or professional engineers must be stamped and signed by the
design professional.
FORME LABuilding New Folder 2010\DONE & x-ferred to L-Building-New drive\Fonn E.doc Updated: 10/2011
10T
'ION, INC.
0
Fire Sprinklers Save Lives!
LETTER OF TRANSMITTAL
0
To: City of Edmonds Date: 3/9/2012
Job No. 11-1821
Project: Premier Orthopedics
Attn: Subject: Fire Sprinkler Drawings
2707 70TH Avenue East
Tacoma, WA 98424
TEL: (253) 926.2290
FAX: (253) 922.6150
We are sending:
xx PRINTS
ORIGINALS
xx CALCULATIONS
DISKS
EQUIP SUB.
Copies
Date
DESCRIPTION
3
3.9.12
Fire Sprinkler Plan for Permit
Comments:
Please return one set of shop drawings with your approval and/or comments.
If you have any questions, please contact me at 253-926-2290 or email me at mark. manning@patriotfire.com
Thanks
By: Mark Manning
HANFORD, WA OFFICE
TEL (509) 373.8895
FAX (509) 373.8919
Cc: Job File
VANCOUVER, WA OFFICE
TEL (360) 699."03
PORTLAND (503) 222.6001
FAX (360) 699.4485
PATRIFP099CF
A `EP!EL.1�
MAR 12 ?np
DEVELopMENT'SERVICE-s ,-TR
CITY OF E[)MolyDS
SPOKANE, WA OFFICE
TEL (509) 926.3428
FAX (509) 926.3708
Eagle Eye Consulting Engineers, P.S.
PO BOX 523
Olalla WA 98359
hoytjeter@centurytel.net
206 356-7790
Fax 206 316-2287
To: Patriot Fire Protection, Inc
2707 70'h Avenue East
Tacoma, WA 98424
Re: Premier Orthopedics Group Wednesday, March 28, 2012
2140172 nd Avenue West
Edmonds, WA
Plan Review Number # 20120162 EECE EDM 12-01
Task Oder Number 12-01
The above referenced project is in the process of plan review for compliance with
Edmonds ordinances and applicable codes (Fire Suppression only). The following
comments, deficiencies/corrections must be addressed prior to completion of plans review
and subsequent issuance of permits.
Provide revised plans and calculations along with a written response to each of the items
listed below to facilitate a shorter back -check time.
SCOPE OF REVIEW
The*scope of this review isfor Fire Suppression requirements of this project.
All features were checked only to the extent allowed by the submittals provided. All
portions of this project are assumed to meet or will meet other departmental requirements,
conditions and concems before permit approval.
Page 2 of 2
EECE# EDM12-01
Premier Orthopedics Group
BLD 2012-0162
FIRE SUPPRESSION COMMENTS
Sheet FP 1:
Riser Room Detail: Where the wet system passes through to the third floor, either
specify flexible couplings within one foot of both sides of the floor or provide an 8
inch sleeve. NFPA 13, 9.3.4
All other details of this plan submittal appear to be acceptable including products, head
location and calculations.
Additional corrections may be required following receipt of corrections and additional
information as requested.
Your plans are being reviewed concurrently with the Building Department, Fire
Department, Zoning Department and Public Works Engineering. Changes, clarifications
or additional corrections may be required subsequent to the Building Department plan
review when comments are received from the other concerned departments.
Should you have any inquiries regarding this letter, please contact Hoyt Jeter at (206) 356-
7790 between 8:00 a.m. and 5:00 p.m.
LO-A
Hoyt Jeter PE
President
01F E D 0 City of Edmond
un
REQUEST FOR PLAN REVIEW CONSULTANT SERVICES
BUILDING DIVISION
(425) 771-0220
Task Order No. j6%�? _4"�q Budget Line Number: 001.000.620.524.100.410
Project Name & Plan Check #
I
Consultant: EAGLE EYE ENGINEERS Consultant Contact Person: Hoyt Jeter Phone: 360-874-0562
Fax: 360-874-0591
City of Edmonds Requester: Leonard Yarberry, Building Official Phone: 425-771-0220 extn 1226
Reimbursable by Applicant:
F1 Yes, by
(Name, address, phone number of person/organization who will reimburse City)
No
DESCRIPTION OF TASK ASSIGNMENT
Review the enclosed plans, calculations and documents, for compliance with State and City adopted building codes
F]
Structural & Non -Structural Plan Review
Fire Sprinkler Plan Review
F_�
Structural Only Plan Review
Non -Structural Only Plan Review
Additional Instructions:
COMPENSATION
F-1 BASED ON CONSTRUCTION VALUATION per Professional Services Agreement
TIME AND MATERIALS per Professional Services Agreement. Compensation for these services will be on a Time
and Materials basis, not to exceed, $_4 i�AwLd without written authorization.
SCHEDULE The Consultant shall complete the services described above as follows:
In accordance with Standard Review Timelines per the Vrofessional Services Agreement
Completed I't review due to City b (see below for subsequent reviews)
Alternate review time as agreed upon in advance wiKthe City per the Professional Services Agreement (only to be used
when approved by the Building Official).
Completed review due to City by (see below for subsequent reviews)
All provisions of the Professional Services Agreement dated 10/26/2009 shall be in full force and effect for this Task Order.
APPROVED:
CITY OF EDMONDS, CONSULTANT
By: By:
LeonWrd Wrberry, Building Official Date Hoyt Jeter, President
RETURN ORIGINAL SIGNED TASK ORDER TO THE CITY
SCHEDULE OF SUBSEQUENT REVIEWS:
F1 2 nd REVIEW DUE TO CITY BY:
F1 3d REVIEW DUE TO CITY BY:
Date
In
L:\TEMP\DST's\Forms\Task Order Forms\Eagle Eye Engineers Task Order Form.doc
0 0
OV Er) -4
011.
CITY OF EDMONDS
PHONE: (425) 771-0220 - FAX: (425) 771-0221
121 5TH AVENUE NORTH - EDMONDS, WA 98020
Monday, March 12, 2012
This Application has been acceptedby the City of Edmonds for review. More information and changes may be
required during this process. The review target date is: Monday, April 02, 2012
Your City Contact is: MARIE HARRISON
Application Number: BLD20120162
Project Address: 21401 72ND AVE W, EDMONDS
PREMIER ORTHOPEDIC GROUP - EDMONDS
MEDICAL
PO BOX 27165
SEATTLE, WA 98125
Work Description:
NEW FIRE SPRINKLER SYSTEM
Outstanding Items at Time of Submittal:
PATRIOT FIRE PROTECTION INC
2707 70Th Ave E
Tacoma, WA 98424
(253) 926-2290
I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION THAT THE INFORMATION GIVEN IS CORRECT
AND THAT I AM THE PROPERTY OWNER, OR THE DULY AUTHORIZED AGENT OF THE PROPERTY OWNER TO SUBMIT
A BUILDING PERMIT APPLICATION TO THE CITY.
�A 1234 A A A IV\-- S� 11-r,41 AnNV-re-IM ?I
SIGNATURE (OWNER OR AGENT) I PRINT NAME DATE
To view up to date information aboutyour application please visit the City ofEdmonds Development Services
website at ht1p.11ww;v.cLedmonds.wa.us.
OV EJ11Af 0
loz
Fom )2-01
City of Edmonds*
REQUEST FOR PLAN REVIEW CONSULTANT SERVICES
BUILDING DIVISION
(425) 771-0220
Task Order No. -6-:91
Project Name & Plan Check #
Budget Line Number: 001.000.620.524.100.410
Consultant: EAGLE EYE ENGINEERS Consultant Contact Person: Hoy! Jeter — Phone: 360-874-0562
Fax: 360-874-0591
City of Edmonds Requester: Leonard Yarbe!1y, Building Official Phone: 425-771-0220 exm 1226
Reimbursable by Applicant:
7 Yes, by
(Name, address, phone number of person/organization who will reimburse City)
MPM
DESCRIPTION OF TASK ASSIGNMENT
Review the enclosed plans, calculations and documents, for compliance with State and City adopted building codes
F� Structural & Non -Structural Plan Review �R Fire Sprinkler Plan Review
F-1 Structural Only Plan Review E] Non -Structural Only Plan Review
Additional
COMPENSATION
El BASED ON CONSTRUCTION VALUATION per Professional Services Agreement
TIME AND MATERIALS per Professional Services Agreement. Compensation for these services will be on a Time
and Materials basis, not to exceed $ —4 '�-Pd without written authorization.
SCHEDULE The Consultant shall complete the services described above as follows:
In accordance with Standard Review Timelmes per the Vrofessional Services Agreement
Completed I` review due to City by (see below for subsequent reviews)
Alternate review time as agreed upon in advance wiKthe City per the Professional Services Agreement (only to be used
when approved by the Building Official).
0 Completed review due to City by (see below for subsequent reviews)
All provisions of the Professional Services Agreement dated 10/26/2009 shall be in full force and effect for this Task Order.
APPROVED:
CITY OF EDMONDS, CONSULTANT
By: ;;� �Z , /' 2--- By:_*--, 114- 7-
LeonWrd YUrberry, Building Official ' Date Hoyt Jeter, President Date
RETURN ORIGINAL SIGNED TASK ORDER TO THE CITY
SCHEDULE OF SUBSEQU NT REVIEWS:
2 d REVIEW DUE TO CITY BY:
3rd REVIEW DUE TO CITY BY:
L:\TEMP\DST's\Forms\Task Order Forms\Eagle Eye Engineers Task Order Form.doc
Eagle Eye Consulting Pngineers, P.S..
P.O. Box 523
Olalla, Washington 98359
(360) 874-0562
�11,lf
CLIENT:
Project Name:
Premier Orthopedics
Edmonds Building Department
121 5th Avenue North
E E C E Prooect Number
EDM 12-01
Edmonds, WA 98020
Ta�k Order No.
12-01
Client Reference Number:
BLD2012-0162
DATE: 3/28/12
For valuation calculation purposes the following classifications for construction type and building use were utilized
Number of stories = 2 CM
I CM
I
Occupancy (Use) Constr. Type
$ Per Square Foot
Gross Area
Building Valuation
X
$0.00
Main Floor
X
$0.00
Upper Floor
X
$0.00
X
$0.00
Garage
X
$0.00
X
$0.00
New Deck
$17.00 X
$0.00
X
X
$0.00
X
X
$0.00
Total:
$0.00
-STATED
-CALCULATED
-DISCREPANCY
IF MORE THAN 10%
VALUATION: 1
$0.001
$0.00
Total Project Valuation
$0.00
$0.00
#DIV/01
DFI:
$ 30.00
$ 30.00
BUILDING PERMIT FEE:
$30.00
$ 30.00
PLANCHECK FEE:
$25.50
$ 25.50
Eagle Eye Consulting Engineering Fees: Box Checked are Fees Used for This Project)
Notes
Eagle Eye Consulting Engineers
Fee (single farnilyf7l
$13.50
$13.50
Eagle Eye Consulting Enginee rsm
FEE (A and S):"
Eagle Eye Consulting Engineersm
FEE (A or S):"
Eagle Eye Consulting Engineersm
Hourly Fee at $85/hour:LXJHours
121
$1,020.00
Not to exceed 2500 dollars
OV ED&
A.
'Y' CITY OF EDMONDS
121 5TH AVENUE NORTH - EDMONDS, WA 98020
oislz PHONE: (425) 771-0220 - FAX: (425) 771-0221
Tuesday, October H, 2011
This Application has been accepted by the City of Edmonds for review. More information and changes may be
required during this process. The review target date is: Tuesday, October 25, 2011
Your City Contact is: MARIE HARRISON
Application Number: BLD20110856
Project Address: 21401 72ND AVE W, EDMONDS
PROPERTYOWN ER APPLICANT
PREMIER ORTHOPEDIC GROUP - EDMONDS PACIFIC FIRE AND SECURITY INC
MEDICAL BAKER, JON T
PO BOX 27165 828 Poplar PI S
SEATTLE, WA 98125 Seattle, WA 98144
(206) 957-09�7
Work Description:
FIRE ALARM SYSTEM FOR NEW ORTHOPEDIC CLINIC
Outstanding Items at Time of Submittal:
I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION THAT THE INFORMATION GIVEN IS CORRECT
AND 7AT I AM THE PROPERTY OWNER, OR THE DULY AUTHORIZED AGENT OF THE PROPERTY OWNER TO SUBMIT
Z7-----A BUILDING PERMIT APPLICATION TO THE CITY.
NAME
DATE SIGNED
To view up to date information about your application please visit the City of Edmonds Development Services
website at http.-1Avww.cLedmonds.wa.us.
OV. EI)Afo
C.) DEVELOPMENT SERVICES
COMMERCIAL & MULTI -FAMILY BUILDING
PERMIT APPLICATION
121 5h Avenue N, Edmonds, WA 98020
City of Edmonds Phone 425.771.02200 Fax 425.771.0221
PLEASE REFER TO THE COMMERCIAL & MULTI -FAMILY BUILDING CHECKLIST FOR SUBMITTAL REQUIREMENTS
PROJECT ADDRESS (Street Suite # City State, Zip): 9802�
el 6,/ -72_,-J -,k L
'01-y' . W -t) -,A-
Parcel #:
C qtOCOT62 -N-7
Subdivision/Lot #:
Project Valuation: $ Apn!!� M
APPLICANT: k
q��c
Phone:
20 6 �- 9 571 — 0 17 1
Fax:
Address LStreet, Cit State Zift 9� M1
172A A 0/;� '?/. ; W k
E-Mail Address:
I
PROPERTY OWNER:
�< V_ k� � 4-y- 0 rA" fz�(_
Phone: -Tax:
Address (Street, City, State, Zip). 97076
2! 146 1 -7 Z,;V Ayt W 6&hv"A, Lk-
E-Mail Address:
LENDING AGENCY:
Phone: - I
Fax:
Address (Street, City, State, Zip):
E-Mail Address:
CONTRACTOR:*
+11 c -( �- V.
Phone:
?,dj- 9-57-090'7
Fax:
1
Address (Street, City St t Zi ). 9V 1114
-9 2- %' 6' P a'A U-1 t)r *
w State License #/Exp. Date:
4)q C_ :r F F 9 1 14 M
*Contractor must have a valid City ofEdmonds business licknse prior to doing work in the
City. Contact the City Clerk's Office at 425.775.2525
City Busnjess Li #/E �ate:
DETAIL SCOPE OF WORK:
t-i 0
PROPOSED NEW SQUARE FOOTAGE
FOR THIS PROJECT:
Basement: sq. ft.
Garage:
6-3� O(J o sq, ft,
I" Floor: sq. ft.
Deck:
sq. ft.
2 d Floor: sq. ft.
Other:
sq. ft.
3'd Floor: 2- 6 6() sq. ft.
Occupancy: Occupancy Load:
Retaining Wall: 0 Yes 0 No
Grading: —cyds.
I Type of Construction:
I declare under penalty ofpeijury laws that the information I have provided on this formlapplication is true, correct and
complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to
the City of Edmonds.
Print Name: D Owner . 2, Agent/Other (specify):
Signature: Date:
FORM E CADocuments and Settings%jorbackWesktopTorm E.doc Updated: 10/2010
ov ED&
CITY OF EDMONDS
121 5TH AVENUE NORTH - EDMONDS, WA 98020
PHONE: (425) 771-0220 - FAX: (425) 771-0221
Monday, September 26, 2011
This Application has been accepted by the City of Edmonds for review. More information and changes may be
required during this process. The review target date is: Monday, November 07, 2011
Your City Contact is: MARIE HARRISON
Application Number: BLD20110816
Project Address: 21401 72ND AVE W, EDMONDS
EDMONDS MEDICAL BUILDING ASSOC., LLC FIRST WESTERN DEVELOPMENT SRVS.
8129 LAKE BALLINGER WAY '§COTTSHANKS
EDMONDS, WA 98026 8129 LAKE BALLINGER WAY
(425) 329-0848 EXT: EDMONDS, WA 98026
(425) 329-0848 EXT:
Work Description:
TENANT IMPROVEMENT FOR A MEDICAL CLINIC. WORK HILL INCLUDE EYAM ROOMS, BUSINESS
AREAS, THREE OPERATING ROOMS, MRI, PHYSICAL THERAPY, AND WAITING AREAS. MECHANICAL
AND PLUMBING INCLUDED.
Outstanding Items at Time of Submittal;
SNOHOMISH HEA TH DISTRICT APPRO VA L.
I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION THAT THE INFORMATION GIVEN IS CORRECT
AND THAT I AM THE PROPERTY OWNER, OR THE DULY AUTHORIZED AGENT OF THE PROPERTY OWNER TO SUBMIT
A BUILDING PERMIT APPLICATION TO THE CITY.
) PN�— 17 g-e:n IM, k-A
SIGNATURE (OWNER OR AGENT) PRINT NAME
To view up to date information about your application please visit the City of Edmonds Development Services
website at http.1Avww.c4edmonds.wa.us.
�1' r- - V
DEVELOPMENT SERVICES
ri-T, , Vol NEU,
COMMERCIAL & MULTI -FAMILY BUILDING
PERMIT APPLICATION
4, 1h
tst. 1 121 5 Avenue N, Edmonds, WA 98020
City of Edmonds Phone 425.771.0220 Ik Fax 425.771.0221
PLEASE REFER TO THE COMMERCIAL & MULTI -FAMILY BUILDING CHECKLIST FOR SUBMITTAL REQUIREMENTS
PROJECT ADDRESS (Street, Suite #, Ci!y State, Zip):
'&'Vsf "110%0^V1LWXCrr01Dt"1J0T,1vA 6Jfi0,1eo
Parcel #:
%.DT- C
Subdivision/Lot #:
Project Valuation: $
S How PLAq hm w w I Lbor - a
APPLICANT: SC -Off Stf#-NILS
Phone:
Fax:
Fl"M WP—Rrtiv% DIEU &"FCA 6 Or SE06VIC-25 ime-
419- 121 - 0949
142C.%2i _o1
Address (Street, City, State, Zip):
Am LAKE 4'a"Of W^ 4IA02L
leor
E-Mail Address:
&CM4041WAI rK
Phone: Fax:
4 IT' 32q - hS 4 A
hZr
__
PROPERTY OWNER:
Umairtlt r4opitAL, IlumnivaL L,4S64iAT11S , IL&
Address (Street, City, State, Zip): 16 1141 LJkKE 19ACA;1146" iWN-1
E-Mail Address:
SOM IA4 F-0-246HOS WA '1907-4
scm 00 ; w cL COM
�'TFax:
LENDING AGENCY:
Phone: —
Address (Street, City, State, Zip):
E-Mail Address:
CONTRACTOR:*
Phone:
Fax:
WING14 COOSNIL"Tph)
'26&- 4 16- 6 M
I
Address (Street, City, State, Zip): IS!603 191 J%%Jt"VV.
WA State License #/Exp. Date:
SU r% 160 P & EAOITJ62 , W,& 91 IN I of%
lFammoef'o I IQ%
City Business License #/Exp. Date:
*Contractor must have a valid City ofEdmonds business license prior to doing work in the
Ci�v. Contact the Citv Clerk's Office at 425.775.2525
14P _ 0 1 r
16 061131
DETAIL SCOPE OF WORK:76MANT % M&LOURE Ad 9 NTS
am THV_!n4 A &
F*tL A MEDUAL, CLA We. -
(119-1W&
I CLO IFI-00 ot be, MEW C.09,19 StICLA.
SUBMI!tTISO 06106RA SEPA6.940KTJ ?^C"42E),
BUIL.01 ?Ore
%M61LIe- W # U.� i va r, #..%) Of- I
EJAW 040 rft
VIA VS 14--&6 TH V 0^ IT I Na #PMAS
JLdo dJ M fLI
PROPOSED NEW SQUARE F
OTAGE FOR THIS PROJECT:
Basement: sq. ft.
Garage:
—sq, ft,
I" Floor: sq. ft.
Deck:
sq. ft.
2 d Floor: sq.
Other:
sq. ft.
3rd Floor: 21 - SS06- sq.
Occupancy:- Occupancy Load:
Retaining Wall: 0 Yes 0 No
-Grading: —cyd . I
Type of Construction:
I declare underpenalty ofperjury laws that the information I haveprovided on this formlapplication is true, correct and
complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to
the City of Edmonds.
Print Name: 0 Owner
0 Agent/Other (specify):
Signature: Date:
FORM E CADocuments and Settings\bjorback\Desktop\Forin E.doc Updated: 10/2010
Equipment Type
Appllance/Equlpment Information (new and relocated)
Total
Furnace
[Air
# Gas #�__Elec #—Other: BTUs: .0 OOk— >1 00k— Location
Handier/ACN"
# Gas # Elec # Other: CFM: <1 OOkX >1 M
004— Location
Bol ler/Com pressor/ i
Heat Pump/Roof Top
Unit
as # Elec # Other: BTIJ9: 100k, 100k.500k,,, .500k-IMII
J�:d — — — .
HP: ___�3-16, 15-30 Location R645 P
Hydronic Heating
# Gas #—Elec —In-Floor, __Wall Radiant, Boller BTU9j 4hK Location
Exhaust Fans (single
ducl)
Location: # -&Bath #-_LKItchen k--Laundry # other: 4
Fireplace
# Gas #—Elec #�-�Iher:_ Location
Other
Number of Outlets
Fixture/Appliance Type
AC Unit --------------
BTUs:12&K
Location: R" F
Furnace --------------
BTIJs:_
Location:
Water Heater -------
BTUs:12&9
Location: MMANICAL MOM
2-
Boiler -----------------
BTUS:-76
Location: ItOOTop MIEC
Fireplace/Insert
BTUS:—
Location:
C>
Stove/Range/Oven;
0
Dryer
0
Outdoor BBQ:
4 IOther:
TOTAL OUTLETS
-Number
Fixture Type
Number
Fixture Type
115
Water Closet (Toilet)
Reftigerator water Supply (for water/ke dispenser)
Sink (kitchen, laundry, lavatory, bar, eye wash, etc.)
Water Service Line
Tub/Shower
Drinking Fountain
Dishwasher
Bidet/Urinal
2
Hose Bib
Pressure Reduction Valve/Pressure Regulator
Water Heater Tankless? Yes— No—
Backnow Prevention Device (e.g. ROPA. DCDA, AVS)
Expansion Tank for Water Heater
Hydronic Heat in: Floor_ Wau
q
L
Floor Drain/Floor Sink
Other: %Cf MAKEN
I
Clothes Washer
Other: 0 1 L. WATgit WftItA.Top.
MS910" GAS%'.
V T L STS
CA OVT I- fal
I -)
EYEWASH
IQ
" UNJ —
Upuatou: JLVZUIV
LT DEVELOPMENT SERVICES
i�- COMMERCIAL & MULTI -FAMILY BUILDING CHECKLIST
Ilk' W—P 1215 1h Avenue N, Edmonds, WA 98020
I %9'� Phone 425.771.0220 2 Fax 425.771.0221
City of Edmonds
PROJECT ADDRESS: W 401 711-MOAVENUE WMT
vomowosswAr qbal(v
PRE -APPLICATION MEETING? 0 YES JKNO If YES, Pre -application Number:
Plans shall be of sufficient clarity to indicate the location, nature, and extent of the work proposed, and conform to the provisions of
the adopted International Codes and City Ordinances.
tv
F
v 90
EW
SUBMITTAL REQUIREMENTS
The number indicates the number of copiesfor
submittal( if applicable). Check marks indicate
additional submittal requirement as applicable
2P z
W
z
0-3
tv
n
AD
q1 021 oil
M M M
>
;,
j
0
tv
Application Form E
Site Plan
3
3
3
3
3
3
Reduced Site Plan (I I X 14 or 8 1/2 x 11)
1
1
1
jB
1
1
1
Architectural Construction Drawings
3
3
3
3
3
Structural Drawing and Calculations
3
1 3
3
3
11
WA State Energy Code NREC Calcs & Lighting
V/
V
V/
V/
Site Classification Worksheet
3
3
Site Development Plans
4
4
Landscape Plan
3
3
Right —of-Way Permit Application
I
I
Critical Areas Determination or Checklist
I
I
Geotechnical Report
3
3
Health District Approval Letter
Io/
Manufacturer's Specifications/Cut Sheets
V/
v/
V/
V/
3
Contractor's City of Edmonds Business License
V/
V
Io/
Washington State Contractors License
V/
V/
Plan Check Fee (due upon submittal)
v/
I/
Traffic Impact Analysis
3
3
3
3
Survey
3
3
Special Inspection and Testing Agreement
V
V/
-1/
-W/
Contractor's Acknowledgement Letter
V/
I/
Envelope Plans and Documents
2
2
Bonds
I
I
Architectural Design Approval
1
1
Peer Review Fees
Deferred Submittals
Shop Drawings
Street Use
• Handouts and Standard Details may be found on the City's website www.ci.edmonds.wa.us or can be obtained at City Hall
during normal business hours.
• Plans/calculation/reports prepared by state licensed architects or professional engineers must be stamped and signed by the
design professional.
FORM E CADocurnents and Settings%jorback0esktopTorm Edoc Updated: 10/2010
CITY OF EDMONDS DAVE EARLING
MAYOR
121 5th AVENUE NORTH & EDMONDS, WA 98020 * (425) 771-0220 - fax (425) 771-0221
www.edmondswa.gov
DEVELOPMENT SERVICES DEPARTMENT
41C. IB913
October 26, 2016
Berkley Regional Insurance Company
7015 1h Ave, Suite 3506
Seattle, WA 98104
Re: Maintenance Bond #0129322; for Edmonds Medical Building Associates,
LLC "Premier Orthopedics" * 2140172 "d Ave W, Edmonds, WA (Permit
BLD2011-0815)
Dear Sir or Madam:
The City of Edmonds hereby authorizes the release of $13,346.04 from the above
referenced Maintenance Bond. All interested City departments have approved the release
of said Bond.
Sincerely,
Kristin Johns
Senior Permit Coordinator
cc: Owner
File
Incorporated August 11, 1890
qictc,r (7itu - Hp.kinan, Janan
MAINTENANCE BOND RELEASE FORM
MEMO TO: PERMIT COORDINATOR, BUILDING DIVISION
FROM: C ENGINEERING DIVISION DATE
PLEZE-SIGN I t
PLANNING DIVISION DATE
PLEME SIGN
DATE SENT TO:JffAnle, 'NAC, (20Y)nO DUE BACK:- 'i�/31115�.ECEIVED:-
PERMIT# 5LD q01 I - bS 16 ADB#
DATE INSPECTED
PROJECT J�E�r))NADK�Q,'�> mep�C-P�11 PECoci,n-r�,!S
SITE ADDRSS- al4bi V-.,)
OWNERS C-1)1\k0$,JDe> Scorn- S�A"V<
OWNER ADDRESS
TYPE OF BOND TO BE RELEASED
AUCLiq
L-7 ) 0
BOND DATE POSTED a0 12 BOND EXPIRES i I 1-zz 1-7,01 L4
Please field inspect at your earliest convenience for the release of the subject bond. If there are
outstanding requirements, please note in the space provided. Failure to respond by the noted bond
expiration date constitutes Department approval and automatic release of the bond. It is each
Department's responsibility to contact the developer/owner when outstanding issue prevent the release
of the bond. Please copy the Permit Coordinator on all City correspondence sent regarding'thi s bond.
C �— BOND IS APPROVED FOR RELEASE
BOND IS NOT APPROVED - OUTST ANDING REQUIREMENTS NOTED
1 .
2.
3.
WORK TO BE COMPLETED WITHIN DAYS
COPY TO FILE SUSPENSE TO
COPY TO DEVELOPER CONTRACTOR
L:\TEMP\BUILDING\FORMS\Certificate 0ccupancy\bondre1.D0C7/17/2009
41-
OV
E D Af r--1 0
T
St. I
Date Bond Posted
Date Bond Expires_
Bond Number 0129322
City of Edmonds
121 5'h Avenue North - Edmonds - WA 98020 - (425) 771-0220 Fax (425) 771-0221
Website: %vw%v.ci.edn1onds.%Ya,us
DEVELOPMENT SERVICES DEPARTMENT
Planning - Building - Engineering
Ri&ht of W hPMVWMtS
MAINTENANCE BOND/BONDING COMPANY
Edmonds Building Permit No. BLD 20110815
Project Address 21401 72nd Ave W
Developer/Owner Edmonds Medical Buildinct Associatea - LLC
W Edmonds Medical Building
H
EREAS, ssociates, LLC hereinafter referred to as "the Principal",
has constructed And installed certain improvements in connection with a project known as
Premier Orthopedics on a site located at 21401 72 Ave W.
within the City of Edmonds, and
WHEREAS, in order to provide security for the obligation of the Principal to repair or replace
any improvement which proves defective within two (2) year(s) (not to exceed two years) from
acceptance of the improvement by the City of Edmonds herein referred to as "the City", and to
enable the City to release the performance bond provided in connection with said improvements,
this bond has been secured and is hereby submitted to the City.
NOW, THEREFORE, the undersigned Principal and Berkley Regional Insurance Compa y
a corporation authorized to transact surety business in the State of Washington, hereinafter
referred to as "the Surety", agree and bind themselves, their heirs, executors, administrators and
assigns, unto the City in the SUM Of$ 13,3465. 04-- , lawful money of the United States,
according to the following terms and conditions:
1) The Principal and Surety agree that in the event that any of the improvements installed by
the Principal or Surety pursuant to the above referenced plans, conditions and file fail to remain
free from defects in materials, workman -ship or installation or in the case of landscaping, fail to
survive for a period of two (2)year(s) from the date of acceptance of the installation by the City,
the Surety shall, upon demand of the City and the failure to cure the defect within a reasonable
time as determined and specified by the City, remit to the City within ten (10) days of receipt of
demand for remittance, the amount of this bond or such.lesser amount as may be specified in the
demand.
2) If the Principal fails to cure any defect within the time period requested by the City, its
employees and agents are hereby authorized to enter onto said property and perform said
work. This provision shall not be construed as creating an obligation on the part of the
City or its representatives.
3) In the event any lawsuit is instituted by the City of Edmonds, the Principal or the
Surety to enforce the terms of this bond or to determine the rights of any party hereunder,
the prevailing party in such litigation shall be entitled to recover from the losing party its
costs, including reasonable attorneys' fees, incurred as a result of such lawsuit.
L:\BuildingNew Folder 2010\Forms�BONDMainBonding.doc6/29/2011
0 0
City of Edmonds Maintenance Bond Bonding Company
Page Two
4) This bond shall remain in force and effect until the obligations secured hereby have been
fully performed and until released in writing by the City at the request of the Surety or the
Principal.
DATEDthiS 20th day of November 2012
'.,,Be,!.-k "Regional Insurance Company Edmonds Medical Building Associates, LLC
"Bond' ompany per wner rincipal
Develo
B� BY:
Scott Shanks, Member
Officer/Titljj�6xana Palacios, Attorney- in- Fact Print Name
—al iftl�' e. suite 3506 8129 Lake Ballinger Way, Ste. 104
F Av
-seaiti '-WA 98104 Edmonds, WA 98026
Mailmg'�Xdaress/Phone Mailing Address
0129322
Bond Number
425-329-084
Phone Number
BONDING COMPANY SURETY ACKNOWLEDGMENT
STATE OF WASHINGTON
ss.
COUNTY OF King
OnthiS 20th , day of November _,2012 , before me, the under-
signed, a Notary Public in and for the State of Washington, duly commissioned and sworn,
personally appeared Roxana Palacios tome knownto bethe Attorney- in- Fact
OfBerkley Regional InsuranceCompany, the corporation that executed the foregoing
instrument, and actmowledged the said instrument to be the free and voluntary act and deed of
said corporation, for the uses and purposes therein mentioned, and on oath stated that
she was authorized to execute said instrument and that
the seal affixed is the corporate seal of said corporation.
WITNESS my hand and official seal hereto affixed the day and year first above written.
Mary A. Dobbs
LP
'TARkW-
Ole
Pusory
By: �n� 4�.
NOTARY PUBLIC in and for the
State of Washington, residing at
Seattle
LABuilding New Folder 2010\Forms\BONDMainBonding.doc6/29/2011
0
E
City of Edmonds Maintenance Bond Bonding Company
Page Three
DEVELOPER/OWNER ACKNOWLEDGEMENT
STATE OF WASHINGTON
ss.
COUNTY OF<
On this 41�� , day of 00ep-M 6�clvl &:, I.L, before me, the under-
signed, a Notary Public in and for the State of Washington, duly commissioned and sworn,
personally appeared Scott Shanks to me known to be the member
Edmonds Medical Building
of Associates, LLC. . the general partnership that executed the foregoing
instrument, and acknowledged the said instrument to be the free and voluntary act and deed of
said partnership, for the uses and purposes therein mentioned, and on oath stated that
was authorized to execute said instrument.
WITNESS my hand and official seal hereto affixed the
0
%Cj E
C')
LAffididing New Folder 2010\Forms\BONDMainBonding.doc6/29/2011
No. 2801
POWER OF ATTORNEY
BERKLEY REGIONAL INSURANCE COMA
WILMINGTON, DELAWARE
NOTICE: The warning found elsewhere in this Power of Attorney affects the validity thereof Please review carefully.
KNOW ALL MEN BY THESE PRESENTS, that BERKLEY REGIONAL INSURANCE COMPANY (the "Company"), a
.2 corporation duly organized and existing under the laws of the State of Delaware, having its principal office in Urbandale, Iowa,
has made, constituted and appointed, and does by these presents make, constitute and appoint: Steven W. Palmer, Holly E. Hfers,
Mary A. Dobbs, Bonny Smith or Roxana Palacios ofKibble & Prentice Holding Company of Seattle, Washington
its true and lawful Attorney -in -Fact, to sip its name as surety only as delineated below and to execute, seal, acknowledge and
ti
deliver any and all bonds and undertakings, with the exception of Financial Guaranty Insurance, providing that no single obliga, on
shall exceed Thirty Million and 00/100 Dollars ($30,000,000.00), to the same extent.as if such bonds had been duly executed and
cn =
Z acknowledged by the regularly elected officers of the Company at its principal office in their own proper persons.
This Power of Attorney shall be construed and enforced in accordance with, and governed by, the laws of the State of Delaware,
> t8
without giving effect to the principles of conflicts of laws thereof. This Power of Attorney is granted pursuant to the following
>1 resolutions which were duly and validly adopted at a meeting of the Board of Directors of the Company held on August 21, 2000:
t� > "RESOLVED, that the proper officers of the Company are hereby authorized to execute powers of attorney authorizing and
Cc 2
qualifying the attorney -in -fact named therein to execute bonds, undertakings, recognizances, or other suretyship obligations on
0 =
0
behalf of the Company, and to affix the corporate seal of the Company to powers of attorney executed pursuant hereto; and
further
RESOLVED, that such power of attorney limits the acts of those named therein to the bonds, undertakings, recognizances, or
manner
other suretyship obligations specifically named therein, and they have no authority to bind the Company except in the
and to the extent therein stated; and further
RESOLVED, that such power of attorney revokes all previous powers issued on behalf of the attorney -in -fact named; and
further
0 RESOLVED, that the signature of any authorized officer and the seal of the Company may be affixed by facsimile to any power
c" of attorney or certification thereof authorizing the execution and delivery of any bond, undertaking, recognizance, or other
suretyship obligation of the Company; and such signature and seal when so used shall have the same force and effect as though
manually affixed. The Company may continue to use for the purposes herein stated the facsimile signature of any person or
persons who shall have been such officer or officers of the Company, notwithstanding the fact that they may have ceased to be
E- such at the time when such instruments shall be issued."
IN WITNESS WHEREOF, the Company has caused these presents to be signed and attested by its appropriate officers and its
0
0
= M corporate seal hereunto affixed this �,2-dav of 2008.
0
cl nal Insurance Company
Attest: Berkley V59
.6 (Seal) By By 2
�r� P'e
Ira &`Lederman Robert P. Cole
Senior Vice President
Senior Vice President & Secretary
t.�2 WARNING: THIS POWER INVALID IF NOT PRINTED ON BLUE "BERKLEY- SECURITY PAPER.
STATE OF CONNECTICUT)
N 0
ss:
COUNTY OF FAIRFIELD
CZ
Sworn to before me, a Notary Public in the State of Connecticut, this A-2 day of 2008, by Robert P. Cole and Ira S. Lederman
>1 who are sworn to me to be the Senior Vice President, and the Senior Vice President and Secretary, respectively, of Berkley Regional Insurance
Z cn
Company.
EILEEN KILLEEN
0 m NOTARY PUBLIC
U Notary Public, State of Connecticut
�E MY COMMISSION EXPIRES JUNE 30,2012
CERTIFICATE
1, the undersigned, Assistant Secretary of BERKLEY REGIONAL INSURANCE COMPANY, DO HEREBY CERTIFY that the foregoing is a
true, correct and complete copy of the original Power of Attorney; that said Power of Attorney has not been revoked or rescinded and that the
authority of the Attomey-in-Fact set forth therein, who executed the bond or undertaking to which this Power of Attorney is attached, is in full
force and effect as of this date.
Given under my hand and seal of the Company, this �2& day of
(Seal)
John F. B
.. . �*�- ' - - tA
9 0
Instructions for Inquiries and Notices Under the Bond Attached to This Power
Berkley Surety Group, LLC is the affiliated underwriting manager for the surety business of: Acadia Insurance
Company, Berkley Insurance Company, Berkley Regional Insurance Company, Carolina Casualty Insurance
Company, Union Standard Insurance Company, Continental Western Insurance Company, and Union
Insurance Company.
To verify the authenticity of the bond, please call (866) 768-3534 or email BSGInquiry@berkleysurety.com
Any written notices, inquiries, claims or demands to the surety on the bond to which this Rider is attached
should be directed to:
Berkley Surety Group, LLC
412 Mount Kemble Avenue
Suite 31ON
Morristown, NJ 0796q,\
Attention: Surety ' Claims Department
Or
email BSGClaim@berkleysurety.com
Please include with all notices the bond number and the name of the principal on the bond. Where a claim is
being asserted, please set forth generally the basis of the claim. In the case of a payment or performance bond,
please identify the project to which the bond pertains.
CITY OF EDMONDS
121 5th AVENUE NORTH - EDMONDS, WA 98020 (425) 771-0220 - fax (425) 771-0221
www.edmondswa.gov
DEVELOPMENT SERVICES DEPARTMENT
1'.7 C. I goo
November 20, 2015
Berkley Regional Insurance Company
7015 1h Ave, Suite 3506
Seattle, WA 98104
DAVE EARLING
MAYOR
Re: Maintenance Bond #0129323; for Edmonds Medical Building Associates,
LLC "Premier Orthopedics" @ 2t401 72 "d Ave W, Edmonds, WA (Permit
BLD2011-0815)
Dear Sir or Madam:
The City of Edmonds hereby authorizes the release of $4,200.00 from the above
referenced Maintenance Bond. All interested City departments have approved the release
of said Bond.
Sincerely,
eo Y�
Kristin Johns
Senior Permit Coordinator
cc: Owner
File
Incorporated August 11, 1890
Sister City - Hekinan, Japan
j: . , I
CITY OF EDMONDS
OV ED-Af CORRECTION NOTICE Scanned
C'4 1P ENGINEERING DIVISION
(425) 771-022.0
City Website: www.edmondswa.gov
DATE: September 25,2015 PERMIT NUMBER: - BLD20110815
Edmonds Medical Building
OWNER: Associates LLC SITE CONTACT: Scott Shanks
nd
ADDRESS: 2140172 Ave W.
TYPE OF INSPECTION: FINAL INSPECTION
F] WORK DESCRIBED BELOW HAS BEEN INSPECTED AND APPROVED
-APPROVED PLANS AND PERMIT JOB CARD MUST BE AVAILABLE TO INSPECTOR
ON SITE I
Z CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE
APPROVED AND/OR THE NEXT P14ASE OF WORK IS STARTED.
RECALL FOR INSPECTION
REINSPECTION FEE MUST BE PAID PRIOR TO NEXT INSPECTION REQUEST.
STOP WORK UNTIL AUTHORIZED TO CONTINUE BY CITY INSPECTOR
There are several locations along the frontage were there is cracking, chipping and settling of the
curb and gutter. All failed sections need to be removed and replaced.
1. Curb and gutter at the catch basin in the driveway of address 21431 72 d Ave W.
2. Gutter panel within south driveway entrance at site.
3. Curb to the north of south driveway entrance (street curb transitioning into private property).
4. All curb and gutter between the mail box and south driveway approach.
0
5. A 2' asphalt cut is required where curb and gutter is removed.
For inspection scheduling call 425-771-0220 x1326.
Page 2 of 2
MAINTENANCE BOND RELEASE FORM
MEMO TO: PERMIT COORDINATOR, BUILDING DIVISION
FROM: ENGINEERING DIVISION DATE
PLEASE SIGN
�LANNING DIVISION DAT
000'
DATE SENTIO. UE BACK:- '�'�J-31 RECEIVED:
PERMIT #. bXZ) 5-ADB# DATE INSPECTED
PROJECT tf;�W\ 0 VTDS M &D I ()� L, k) 6) -f�(- .
SITE ADDRSS- 2., 1 L�b -2� K��- P(Vf,:7' t'l.)—
OWNERS M C--,J) 1'C1\-L-,, 6W�,6� /
OWNER ADDRESS.00cl WPkA 10q
TYPE OF BOND TO BE RELEASED s 4 h
I 01L.-I —
BOND DATE POSTED 1-,76 - V2- BOND ENPIRES it zz 14
Please field inspect at your earliest convenience for the release of the subject bond. If there are
outstanding requirements, please note in the space provided. Failure to respond by the noted bond
expiration date constitutes Department approval and automatic release of the bond. It is each
Department's responsibility to contact the developer/owner when outstanding issue prevent the release
of the b7lease copy the Permit Coordinator on all City correspondence sent regarding this bond.
BOND IS APPROVED FOR RELEASE -:�&�e4 e-� PD I .
BOND IS NOT APPROVED - OUTSTANDING REQUIREMENTS NOTED
t
2.
3.
WORK TO BE COMPLETED WITHIN DAYS
COPY TO FILE SUSPENSE TO
COPY TO DEVELOPER CONTRACTOR
L:\TEMP\BUILDING\FORMS\Certificate 0ccupancy\bondre1.D0C7/17/2009
S�, t�%
ov EDAJ 0 Date Bond Posted
0 Date Bond Expires
Bond Number 0129323
City of Edmonds
1h
Edmonds - WA 98020 - (425) 771-0220 Fax (425) 771-0221
121 5 AvenueNorth
Website: %v%vw.ci.edmonds.%va.us
DEVELOPMENT SERVICES DEPARTMENT
11-W K)
st 19,9 Planning - Building - Engineering
. I og
MAINTENANCE BOND/BONDING COMPANY
Edmonds Building Permit No. -
Project Address 21401 72nd
BLD 2011081S
Ave W
Developer/Owner Edmonds medical Building Associates. LLC
Edmonds Medical Building
W
HEREAS, Associates, LLC hereinafter referred to as "the Principal",
has constructed and installed certain improvements in connection with a project known as
Premier Orthopedics — on a site located at 2 14 0 1 7 2 Ave W.
within the City of Edmonds, and
WHEREAS, in order to provide security for the obligation of the Principal to repair or replace
any improvement which proves defective within two (2) year(s) (not to exceed two years) from
acceptance of the improvement by the City of Edmonds herein referred to as "the City", and to
enable the City to release the performance bond provided in connection with said improvements,
this bond has been secured and is hereby submitted to the City.
NOW, THEREFORE, the undersigned Principal and i3erkley Regional Insurance Compa y
a corporation authorized to transact surety business in the State of Washington, hereinafter
referred to as "the Surety", agree and bind themselves, their heirs, executors, administrators and
assigns, unto the City in the SUM Of$ 4,200. 00-- _, lawful money of the United States,
according to the following terms and conditions:
1) The Principal and Surety agree that in the event that any of the improvements installed by
the Principal or Surety pursuant to the above referenced plans, conditions and file fail to remain
free from defects in materials, workmanship or installation or in the case of landscaping, fail to
survive for a period of two (2)year(s) from the date of acceptance of the installation by the City,
the Surety shall, upon demand of the City and the failure to cure the defect within a reasonable
time as determined and specified by the City, remit to the City within ten (10) days of receipt of
demand for remittance, the amount of this bond or such lesser amount as may be specified in the
demand.
2) If the Principal fails to cure any defect within the time period requested by the City, its
employees and agents are hereby authorized to enter onto said property and perform said
work. This provision shall not be construed as creating an obligation on the part of the
City or its representatives.
3) In the event any lawsuit is instituted by the City of Edmonds, the Principal or the
Surety to enforce the terms of this bond or to determine the rights of any party hereunder,
the prevailing party in such litigation shall be entitled to recover from the losing party its
costs, including reasonable attorneys' fees, incurred as a result of such lawsuit.
LABuilding New Folder 2010\Forms\BONDMainBonding.doc6/29/2011
4 1
`Z4
City of Edmonds Maintenance Bond Bonding Company
Page Two
4) This bond shall remain in force and effect until the obligations secured hereby have been
fully performed and until released in writing by the City at the request of the Surety or the
Principal.
DATEDthiS 20th day of November 5 2012
Berkley Regional Insurance Company
'Boind1w"Company
Officer/Thie Roxana Palacios, Attorney -in -Fact
�01'Fitth_.Ave., Suite 3506
-.qeattle.'
Mail-ing. Address/Phone
'0129323
Bond Number
Edmonds Medical Buildinq Associates, LLC
Develop wner/i' rincipal
PrintNamesc"tt shanks, Member
8129 Lake Ballinger Way, Ste. 104
Edmonds, WA 98026
Mailing Address
425-329-0848
Phone Number
BONDING COMPANY SURETY ACKNOWLEDGMENT
STATE OF WASHINGTON
ss.
COUNTY OF King
OnthiS 20th , day of November _,2012 , before me, the under-
signed, a Notary Public in and for the State of Washington, duly commissioned and sworn
personally appeared Roxana Palacios Jorne known to be the. Attorney -in- Fact —
OfBerklev Regional Insurance Compan the corporation that executed the foregoing
instrument, and acknowledged the said instrument to be the free and voluntary act and deed of
said corporation, for the uses and purposes therein mentioned, and on oath stated that
she was authorized to execute said instrument and that
the seal affixed is the corporate seal of said corporation.
WITNESS my hand and official seat hereto affixed the day and year first above written.
Mary A. Dobbs
B y of- oe�
!A�- 0 NOTARY PUBLIC in and for the
State of Washington, residing at
k N
Seattle
PUBL%G j
5
,99F W
LABuilding New Folder 20 10\Forms\BONDMainBonding.doc6/29/2011
0
City of Edmonds Maintenance Bond Bonding Company
Page Three
DEVELOPER/OWNER ACKNOWLEDGEMENT
STATE OF WASHINGTON )
) ss.
COUNTY OU )
On this day of �06e before me, the under-
signed, a Notary Public in and for the State of Washington, duly commissioned and sworn,
personally appeared Scott Shanks to me known to be the member
Edmonds Medical Building
of Associates, LLQ. � the general partnership that executed the foregoing
instrument, and acknowledged the said instrument to be the free and voluntary act and deed of
said partnership, for the uses and purposes therein mentioned, and on oath stated that
he.
was authorized to
WITNESS my hand and official seal hereto affixed the day and
said instrument.
400,12"N %_ ISU "Its
BY: �j
01 Z NOT _PbBfffd' in
t
A.V
.r'$ "�; P
go le o ashington, r
0
Aug%-\
Nib
72-31 -R;ee
ON
LABuilding New Folder 2010\Forms\BONDMainBonding.doc6/29/2011
No. 2801
POWER OF ATTORNEY
BERKLEY REGIONAL INSURANCE COMA
WILMINGTON, DELAWARE
NOTICE: The warning found elsewhere in this Power of Attorney affects the validity thereof. Please review carefully.
RANCE COMPANY, (the "Company"), a
KNOW ALL MEN BY THESE PRESENTS, that BERKLEY REGIONAL INSU
v corporation duly organized and existing under the laws of the State of Delaware, having its principal office in Urbandale, Iowa,
�a
has made, constituted and appointed, and does by these presents make, constitute and appoint: Steven W. Palmer, Holly E. [fifers,
Mary A. Dobbs, Bonny Smith or Roxana Palacios of Kibble & Prentice Holding Company of Seattle, Washington
its true and lawful Attorney -in -Fact, to sign its name as surety only as delineated below and to execute, seal, acknowledge and
deliver any and all bonds and undertakin 9, with the exception of Financial Guaranty Insurance, providing that no single obl gation
.9
shall exceed Thirty Million and 00/100 Dollars ($30,000,000.00), to the same extent as if such bonds had been duly executed and
-2 Z acknowledged by the regularly elected officers of the Company at its principal office in their own proper persons.
This Power of Attorney shall be construed and enforced in accordance with, and governed by, the laws'of the State of Delaware,
> wing
;3 without giving effect to the principles of conflicts of laws thereof. This Power of Attorney is granted pursuant to the follo
resolutions which were duly and validly adopted at a meeting of the Board of Directors of the Company held on August 21, 2000:
E
> "RESOLVED, that the proper officers of the Company are hereby authorized to execute powers of attorney authorizing and
qualifying the attomey-in-fact named therein to execute bonds, undertakings, recognizances, or other suretyship obligations on
behalf of the Company, and to affix the corporate seal of the Company to powers of attorney executed pursuant hereto; and
further
0
RESOLVED, that such power of attorney limits the acts of those named therein to the bonds, undertakings, recognizances, or
other suretyship obligations specifically named therein, and they have no authority to bind the Company except in the manner
and to the extent therein stated; and further
RESOLVED, that such power of attorney revokes all previous powers issued on behalf of the attorney -in -fact named; and
ftirther
RESOLVED, that the signature of any authorized officer and the seal of the Company may be affixed by facsimile to any power
of attorney or certification thereof authorizing the execution and delivery of any bond, undertaking, recognizance, or other
suretyship obligation of the Company; and such signature and seal when so used shall have the same force and effect as though
manually affixed. The Company may continue to use for the purposes herein stated the facsimile signature of any person or
E
= persons who shall have been such officer or officers of the Company, notwithstanding the fact that they may have ceased to be
U C:L�
E such at the time when such instruments shall be issued."
ff and its
IN WITNESS WHEREOF, the Company has caused these presents to be signed and attested by its appropriate o icers
0
0 '.
r. bb corporate seal hereunto affixed this )41-dav of P��� 2008.
0
Attest: Berkley V01 nal Insurance Company
0 �6 (Seal) By By
0 Ira.&'Lederman Robert P. Cole
t 0 Senior Vice President & Secretary Senior Vice President
Z �0 -
E
RITY PAPER.
WARNING: THIS POWER INVALID IF NOT PRINTED ON BLUE "BERKLEY" SECU
STATE OF CONNECTICUT)'
N 0
ss:
COUNTY OF FAIRFIELD
Sworn to before me, a Notary Public in the State of Connecticut, this 1,2 day of 2008, by Robert P. Cole and Ira S. Lederman
>=' CQn who are sworn to me to be the Senior Vice President, and the Senior Vice President and Secretary, respectively, of Berkley Regional Insurance
Company.
EILEEN KILLEEN
NOTARY PUBLZC
Notary Public, State of Connecticut
MY COMMISSION EXPIRES JUNE 30,2012
t
CERTIFICATE
I, the undersigned, Assistant Secretary of BERKLEY REGIONAL INSURANCE COMPANY, DO HEREBY CERTIFY that the foregoing is a
true, correct and complete copy of the original Power of Attorney; that said Power of Attorney has not been revoked or rescinded and that the
authority of the Attomey-in-Fact set forth therein, who executed the bond or undertaking to which this Power of Attorney is attached, is in full
force and effect as of this date. '20� :;;�Q— I
Given under my hand and seal of the Company, this - day of
(Seal) J . An F. B 79
Instructions for Inquiries and Notices Under the Bond Attached to- This Power
Berkley Surety Group, LLC is the affiliated underwriting manager for the surety business of: Acadia Insurance
Company, Berkley Insurance Company, Berkley Regional Insurance Company, Carolina Casualty Insurance
Company, Union Standard Insurance Company, Continental Western Insurance Company, and Union
Insurance Company.
To verify the authenticity of the bond, please call (866) 768-3534 or email BSGInquiry@berkleysurety.com
Any written notices, inquiries, claims or demands to the surety on the bond to which this Rider is attached
should be directed to:
Berkley Surety Group, LLC
412 Mount Kemble Avenue
Suite 31ON
Morristown, NJ 07960
Attention: Surety Claims Department
Or
email BSGClaim@berkleysurety.com
Please include with all notices the bond number and the name of the principal on the bond. Where a claim is
being asserted, please set forth generally the basis of the claim. In the case of a payment or performance bond,
please identify the project to which the bond pertains.
Thornquist, Linda
From: McConnell, Jeanie
Sent: Tuesday, September 29, 2015 10:10 AM
To: Thornquist, Linda
Cc: Johns, Kristin; Rivera, Chris
Subject: Premier Ortho - Edmonds Medical - 72nd Ave W RE: Maintenance Bond Releases
FYI — this was inspected last week and corrections were sent out. Permit Trax has been updated with the latest info and
this is back in the applicants court right now.
Thanks!
Jeanie
From: Thornquist, Linda
Sent: Tuesday, September 22, 2015 2:54 PM
To: Machuga, Jen; McConnell, Jeanie; Zulauf, JoAnne
Cc: Johns, Kristin
Subject: Maintenance Bond Releases
BUILDING PERMIT PERMITM BLD2011081 5
PROP OWNER: EDMONDS MEDICAL BLDG. ASSOC. LLC STATUS: FINAL
ADDRESS: 21401 72ND AVE W, EDMONDS
Tyler from First Western is looking for the Bond Release on this project. He knows that Planning went out there and
had some issues. He said he talked to Jenn and he had "reasons" as to why they couldn't do it ... ? He apparently is
waiting on answers from us. (Tyler 425-329-0848 or TYLER@FWDSINC.COM) Engineering ... Have you inspected? if not,
can you asap? Thank you, Linda
Linda Thornquist
Senior Permit Coordinator
City of Edmonds 425-771-022o ext. 1336
Our hours arefi-om 8am to 4--30Pm Monday, Tuesday, Thursday and Friday.
0 UR PERMIT CO UNTER IS CLOSED ALL DA Y ON WEDNESDAYS!
<< OLE Object: Picture (Device Independent Bitmap) >>
Letter of Transmittal Washington State Department Of
April 20, 2012 RECEIVED 44eHealth
APR2 0 2012 Construction Review Services
3 10 Israel Rd. SE
DEVELOPMENT SERVICES Tumwater, WA 98501
COUNTER
Project Info:
CRS# 60237493
Kruger Orthopaedics
NFPA 101, 2000 Version ASC
Relocation of ASC
Key People:
Assigned DOH
Steve Pennington
Reviewer:
steve.pennington@doh.wa.gov
Facility
Kruger Clinic Orthopaedics, PLLC
Administrator:
Marilyn Degan
21600 Highway 99 Ste 130
Edmonds, WA 98026
(425) 774-2637 x.
judy@krugerortho.com
Architect
Architectural Werks Inc
Engineer:
Janet Monda
12020 113'h Ave NE, Ste 2 10
Kirkland, WA 98034
(425) 823-2244 x.
janet@awerks.com
Consultant:
Pennon Construction Company Inc
Mac Sele
5303 1" Ave S Ste 100
Seattle, WA 98108
(206) 418-0235 x.
macs@pennonconstruction.com
Contact:
SME Inc of Seattle
Dallas Anderson PE
828 Poplar PI S
Seattle, WA 98144
(206) 788-3829 x.
dallasa@smeincofseattle.com
Copies To:
Local AHJ: City of Edmonds
Architect / Engineer: Architectural Werks Inc
Consultant: Pennon Construction Company Inc
Consultant: Bellevue Mechanical Inc
Contact: SME Inc of Seattle
El Contact: N/A
Z CRS File
PO Box 47852
Olympia, Washington 98504-7852
www.doh.wa.gov/crs
tel. 360-236-2944
fax. 360-236-2901
Project 21401 72nd Ave W
location: Edmonds, WA 98026
Suite 3A
Local Permit #:
Facility Contact: Same As Administrator
KI
Local AHJ: City of Edmonds
Leif Biorback
121 5th Ave N
Edmonds, WA 98020-3146
(425)771-0220 x.
Bjorback@ci.edmonds.wa.us
Consultant: Bellevue Mechanical Inc
Larry Boyer
1331 120' Ave NE
Bellevue, WA 98005
(425) 679-5931 x.
larry.boyer@bellevuemechanical.com
Contact: N/A
X.
El DOH Child Birth Center Licensing
F-1 DOH Office of Accommodations & Res. Care Survey
DOH Office of Investigations & Inspections
DSHS, Div. Of Alcohol & Substance Abuse
DSHS, Aging & Adult Services Admin.
L&I, Bill Eckroth, Electrical Section
L&I. John Harvey, Factory Assembled Structures
Page 1 of 16 Plan Review Comments for Project #60237493
t-acnity vata uertiticate:
Facility Name: Kruger Orthopaedics
Site Address: 21401 72nd Ave W
Edmonds, WA 98026
Estimated Date of Occupancy: 12/2012
Licensee UBI#: 601850391
Critical Access Facility: 0 Yes E No
Occupancy B
Construction
2-B
Applicable Code: 2000 NFPA 101
Group:
Type:
�n
Number of Current:
N/A
Added:
Removed: Total:
Beds:
Automatic Fire Sprinkler System: N Yes
El No
Type 13
Automatic Fire Alarm System:
N Yes
E] No
Compartmentation req'd:
NYes
F-JNo
Smoke Control System Provided: F-I Yes NNo
P�4
Special Delayed Egress Control:
0 Yes
NNo
Location:
Certificate of Need Required:
F] Yes
E]No
CON Approval Granted: El Yes [—]No
CON Number:
Number of units: Private occupancy: Two person occupancy:
Based on size of rooms used for sleeping Residents
U Z
0 Based on size of common rooms Residents
Maximum allowable licensable beds:
Z *4
Qualifies for Assisted Living Funding Program F-I Yes E]No Number of qualifying units:
U
Cn -<
This facility will be using general anethesia.
0
Z
The data above is based on the information presented to CRS. Any change in the facility or facility program that
causes the above information to be incorrect is subject to review by CRS. Approval for construction is not
approval for licensure. A copy of the facility data certiflcate will be sent to the licensing agency.
Page 2 of 16 Plan Review Comments for Project #60237493
Project Status:
- Authorized to Begin Construction -
The construction documents have been reviewed per Chapter 246-330 WAC Ambulatory surgery facilities
and found acceptable. The stamped approved copy of the documents shall be kept and available for the
licensing staff on site. Please note the following:
Any changes/deviations (incl. change orders or addenda) from the approved documents must be
submitted to the Department for review and approval. Please include your CRS number on all
communications to Construction Review Services.
You must notify the department when construction is complete, either by the included notification of
construction complete (pink card) or by completing the form on the CRS website. Additional
instructions may be printed on the pink card.
When we receive notification, we will notify DOH Office of Health Care Survey that you have
completed the review process and are ready for licensing.
Ambulatory surgery facility licensing regulations do not allow use of the completed project area until
the Office of Health Care Survey has been notified by CRS that the project has been completed.
The local building official is responsible for building construction permitting and occupancy.
Final licensing approval may be subject to a site inspection by DOH Office of Health Care Survey to
verify compliance with Ambulatory surgery facility licensing regulations.
If you have any questions please feel free to contact Construction Review Services. You can monitor project
status and fill out our online survey at www.doh.wa.gov/crs.
PROJECT CLOSE-OUT REQUIREMENTS You must notify the department when construction is
complete by completing the following steps:
Verify that you have resolved all of the comments on this form and have submitted any revisions
Complete the Online Notification of Construction Completed at:
http://static.doh.wa.gov/hsaa/fsl/CRS/i)ink card.htm
Email or fax the assigned reviewer (see page 1) a copy of the approval from the local building
department (final permit approval or certificate of occupancy); and
Email or fax the assigned reviewer a floor plan showing the scope of work.
You will be recommended to Licensing, when you have completed these items.
You can monitor project status at www.doh.wa.gov/crs.
Page 3 of 16 Plan Review Comments for Project #60237493
Technical Assistance (TA) Comments
U
TA _ July I 11h 2011
Attendees:
Steve Pennington (steve.penninatonAdoh.wa.goy) - Department of Health
Marilyn Degan - Premier Orthopedics
Janet Monda — Architectural Werks
Mac Sele — Pennon Construction
Design and Construction team
The preceding are preliminary comments provided as information and for use preparing the
construction documents. These preliminary comments may be revised during subsequent
submissions/conferences. Additional preliminary comments may be made during subsequent
submissions.
Items Received: Sketch
TI Contact Certificate of Need at (360) 236-2955 to confirm what actions are needed with the
relocation of your Ambulatory Surgery facility.
LIFE SAFETY:
T2 The main entry stair is a communicating space that the life safety code will look at more
restrictively and will require a separation of the floors environmentally with a smoke barrier
separation on the third floor in a fully sprinklered building. The doors on the third floor leading
into the vestibule will need relites in order for the public to ascertain whether there is a risk in
using this exit way in the event of a fire.
T3 The wall separating the ASF from the clinic will need to be a fire partition as noted in the
Washington state amendments to the International building codes in Chapter 422.
T4 The wall around the medical gas storage/manifold room on the Is' floor level of the parking garage
will be required to have a one hour fire barrier surrounding it.
T5 The number 5 gauss line will have to be contained within the MRI area, so that it does not affect
ASF patients or the public using the exit access corridors.
T6 Doors must swing in the path of egress where there are 50 or more occupants using the allowance
of 100 square feet per person.
Page 4 of 16 Plan Review Comments for Project #60237493
U
Architectural:
T7 Drugs must be stored in a secured location, including refrigerated medications.
T8 Patient toilets rooms must have doors that prevent entrapment.
T9 Rooms that a clean or dirty with required pressure relationships should be provided with door
closers to ensure that the pressure relationship is always maintained.
TIO Public corridors are required to be a minimum of 5 feet wide except where stretchers are moved
and then an 8 foot wide corridor is required.
T11 A washable drop ceiling is permitted in the surgery corridor as long as it is clipped or gaskets or
uses a ceiling tile that is a minimum of one pound in weight per square foot and sits flat in the
ceiling grid.
T12 Clearances for the PACU stations are 5 feet between gurneys and 4 feet off of a wall.
T13 Patient restrooms supporting the PACU would need a means for disposing of fluid waste, a spray
wand would be acceptable.
T14 A clinical flush sink is required for the decontamination room.
T15 The soiled utility room could be used as a soiled holding space for the Neptune unit docking
station, soiled linen storage and infectious waste storage.
T16 The billing office being open to the corridor is of a concern if they have any substantial amount of
fuel load from files above that of a normal hazard level for a business occupancy.
Mechanical:
T17 A level one medical gas system is required, with a duplex vacuum pump and redundant oxygen
supplied from a fully piped manifold gas system.
T18 Only two vacuum outlets per operating room will be required to be piped in, as the Neptune unit
will satisfy the requirement of the third vacuum outlet.
T19 A medical gas zone valve is required outside of each operating room and one for the recovery
room is also required outside of the outlets environment.
Page 5 of 16 Plan Review Comments for Project #60237493
U
T20 Inferred controls for the scrub sink and faucet is acceptable as long as the faucet is a gooseneck.
Handle controls for hand -washing can be either wing handles or single lever.
T21 A hot water re -circulating loop must be provided for the domestic hot water.
T22 A fully ducted supply and return air system is required for the ASF.
T23 Insulation of ducting should be exterior mounted to allow cleaning of ducting.
T24 Low wall returns on the opposite walls and as far apart as possible shall be installed in the
operating rooms. Laminar, non aspirating diffusers shall be used on the supply air.
T25 Air exchanges in the operating rooms shall not exceed 20 ACH. Any amount over the 20 ACH
would need to be reviewed and supported by an ICRA, studies and consistent with
recommendations from ASHRAE, CDC, NIH.
T26 Back flow protection for the building and any equipment connected to the domestic water system
will be required.
Electrical:
T27 An emergency power generator system shall be provided meeting NFPA 110 and NFPA 99.
T28 Security of the generator and fuel tank shall be provided.
T29 A remote generator enunciator shall be provided at a nurse station where it can be monitored
during business hours.
T30 The branches of emergency power shall be provided, consisting of the Life safety branch, critical
power branch and an equipment branch. The associate devices shall be placed on those branches as
permitted by code.
T31 All outlets shall be hospital grade.
T32 Medical gas area alarms shall be provided for the PACU and the operating rooms.
T33 Lighting in the operating rooms shall have lens and gaskets.
T34 All patient bed locations shall be served from two sources of power.
Page 6 of 16 Plan Review Comments for Project #60237493
0
U
T35 Provide exit signs that clearly delineate the required exit pathways.
T36 Provide exit access pathway lighting.
T37 Surgery suites will need a code blue emergency call button.
Intake conference 11/15/11:
T38 How will the generator be fueled when there is no access within the property of the owner?
WAC 246-330-510
T39 How are the .5 guass lines for the MR1 contained away from public areas?
T40 Structural engineering buy off on overhead booms for lights or service must be provided.
T41 Freeze protection in exterior stair must be provide for wet sprinkler systems per NFPA 13
T42 Revise life safety plan to show travel distances to the two require exit stairs that meet NFPA 10 1.
T43 Smoke venting for anesthetizing locations to be provided per NFPA 99 Chapter 5.
T45 The life safety branch of the emergency power system shall provide power to exit sign, exit access
pathway lighting and services required to be on the life safety branch per NFPA 99 Chapter 3-4.
Page 7 of 16 Plan Review Comments for Project #60237493
Kruger Otthopaedics
NFPA 101, 2000 Version ASC
Relocation of ASC
Plan Review Comments:
>
LI
>
<
E
0 0
U Z
General:
I [E) Two complete plans and specifications for the fire alarm system installation or
modification shall be submitted for review and approval prior to system installation.
The department reserves the right to defer plan review and inspections to the local
authority having jurisdiction (AHJ). Plans and specifications shall include, but not be
limited to, a floor plan; location of all alarm -initiating and alarm -signaling devices;
alarm -control and trouble -signaling equipment; annunciation; power connection; battery
calculations; conductor type and sizes; voltage drop calculations; name, address, and
phone number of the agency receiving off -premises transmission of alarm; and the
manufacturer, model numbers, and listing information for all equipment, devices, and
materials. Incomplete plans and specifications will be returned without review. Plans
and specifications may be submitted separately from construction documents during the
construction of the project. For small renovation projects in which devices are only to be
relocated or very few devices are to be added, provide two plans that shows the
relocation of devices which may be submitted for review in lieu of the above
requirements. This information can be included on the electrical or architectural plans.
Verify with Department staff to determine if the scope of your project meets this criteria.
Section 907. 1, International Fire Code
Approved 1/30/11 — based on a pull stations also being located at stairwell # 2 door
on level 3 and a pull station being located at the front entry door to the ASF per red
lined drawings FA1.3
2 IHI i Two sets of sprinkler system working plans shall be submitted for review and approval
before any equipment is installed or remodeled. The department reserves the right to
defer plan review and inspections to the local authority having jurisdiction (AHJ).
Deviation from approved plans will require permission. Plans and specifications,
including hydraulic calculations, that are incomplete or are not stamped by a Washington
State Licensed Fire SDrinkler Contractor. will be returned without review. Plans and
specifications may be submitted separately from construction documents during the
construction of the project. For small renovation projects in which heads are only to be
relocated, a plan that shows the relocation of devices can be submitted for review in lieu
of the above requirements. Section 903. 1, International Fire Code
(A)Note: Sprinkler heads in the operating rooms are required to be the clean room
concealed type to meet the monolithic ceiling finish requirements of the 2006 FGI.
Page 8 of 16 Plan Review Comments for Project # 60237493
Kruger Orthopedics
NFPA 101, 2000 Version ASC
Relocation of ASC
Approved 11/5/11 — Based on cut sheets provided that meet the above requirement.
(B)Provide fire sprinkler protection in the stairwells to meet the minimum of one at the
top of the stair shaft and under the first landing above the bottom of shaft per NFPA 13
5-13.3 (reference sheet 4 of 4 of Patriots drawing)
Approved 11/5/11 — Based on cut sheets provided and response that the heads will
be provided.
Contact the Certificate of need program with the Department of Health at (360) 236-2955
to process the change of location for your Licensed Ambulatory surgery facility.
Response: Judy Wood has contacted DOH staffper SP recommendation. It was
suggested to re -contact and begin in 2 months.
4 El Provide in the functional program per 2006 FGI 1.2-2.1 the following:
(a)What types of procedure will be performed at the new site.
(b)Where are medications stored and secured. This would also include securing of
refrigerated medications.
(c)ls the ice machine conveniently located for emergency use for patient in
hypothermia?
(d)How/ where are laundry services provided?
Approved 1/30/11 — based on comment response and updated functional program.
El How will continued access be provided to the emergency power generator for fuel
re -supply with no direct access from on -the -property is provided? WAC246-330-510
(reference sheet A-101)
Approved 1/30/11 — based on response that a fuel fill line will be added where the
fuel truck can fill the generator tank from the front of the building.
6 El Provide steel bollard protection from vehicle damage to the generator and fuel tank from
the neighboring parking lots per International Fire Code 3404.4.6
Locate these bollards no less than four feet on center per lFC Section 312.
Approved 1/30/11 — based on drawings that show the bollards installed.
7 El Provide an exterior door or access next to the storage room on the east wall of the first
floor to provide easy access to the generator for maintenance and testing purposes per
NFPA 110 Chapter 6. (reference sheet A-111 grid line H2/3)
Page 9 of 16 Plan Review Comments for Project # 60237493
Kruger Orthopaedics
NFPA 101, 2000 Version ASC
Relocation of ASC
Approved 1/30/11 — based on a new door out of the storage room that accesses the
generator.
8 El Provide a detail for the concrete service pad and seismic restraint for the emergency
power generator and how clear service access will be provided per the manufacturer
around the unit. WAC 246-330-505 (reference sheet C2)
Approved 1/30/11 — based on drawings section that shows the concrete pad and
seismic notes for anchoring.
9 0 1 Note: On fire rated doors that are designated to have door protection, the maximum
I
height of a non -listed applied panel is 16 inches above the bottom of door per NFPA 80
2-4.5 unless the door comes as an approved assembly with the door protection. Revise
specifications per the above. (reference note # 7 on sheet A9. 1)
Approved 11/5/11 — Based on comment response and modification of the door
schedule to meet the above requirement on fire rated doors.
10 21 Provide door closers on the following doors to maintain the required pressure
relationships per Table 2.1-2 of the 2006 FGI:
A307A, A313A, A313A, A315A, A302A, A325A, A324A and A324A
(reference sheet A2. 1,A9.1 &A9. I B)
Approved 1/30/11 — based on sheets AMB that added the door closers.
I I El Provide verification that the .5 gauss line for the MRI is contained away from public
areas per 2006 FGI 2.1-5.5.5.8 (2) in the Lobby/Latte area. (reference sheet A2.4)
Approved 11/5/11 — Based on sheet A2.6 dated 11/30/11 that shows the .5 gauss lined
contained.
i
12 El ii Provide a structural engineered sign off on the support systems for the surgical lighting
system per WAC 246-330-505 (reference sheet A6.3 section # 11)
i Approved 1115111 — Based on sheet S8.02 that provides an engineered support
i
system.
13 IK Provide details showing how the vertical and horizontal joints in the hygienic wall
covering wainscot in the operating rooms will be joined to fon-n a monolithic finish per
2006FG13.7-5.2.2.4(3) (reference sheet A9.2 and A6.1)
Not Approved 1/3 0/11 — The vertical weld joint is acceptable, but the "J" mold top start
edge trim is not acceptable, as it does not form a good seal against the wall protection. A
Page 10 of 16 Plan Review Comments for Project # 60237493
Kruger Orthopedics
NFPA 101, 2000 Version ASC
Relocation of ASC
solid surface trim piece or just a caulked top of wall protection to the wall is acceptable.
Provide alternate top trim detail.
Approved 4/2/12 — Based on modified note on sheet A9.2
14 El Provide a stamped and signed plumbing drawing by the engineer of record
per WAC 246-330-505
Approved 1/30/11 — based on signed plumbing drawings received.
Life Safety:
15 El Provide a 45 minute rated fire door to the medical gas storage room that is one hour rated
per NFPA 10 1 Chapter 8.2.3.2.3.1 (2) (reference sheet A- 119 and A- I 11)
I Approved 1/30/11 — based on comment response that added the door rating.
16 FxI Provide a two hour fire barrier with a 90 minute rated fire door around the elevator
equipment room per the International Building Code Section 3006.4
(reference sheet A- I 11)
Approved 1/30/11 — based on drawing that shows the 2 hour rating.
17 El Provide a one hour fire barrier around the Electrical service room on the first floor and a
second exit meeting NFPA 70 f Article 110.26 (C) (2) for rooms with over 1200 amps of
service and equipment over 6 feet wide.
Approved 1/30/11 — based on the one hour rating being provided and no second
door being required as they are providing twice the work area per the exception.
18 a] Provide an updated life safety plan for the 3d floor showing the two required exits per
NFPA 10 1 Chapter 20 separate from the atrium exit that has been separated by a one
hour smoke barrier. WAC 246-330-505
Approved 11/5/11 — Based on comment response that made the two exit stair
enclosures # 2 and #3 the two required exits for the ASF.
19 El Change the swing of door # A3 3 1 B to swing in the path of travel to access the second
NFPA exit stair # 3 per NFPA 10 1 Chapter 7.2.1.4.2
Approved 11/5/11 — Based on comment response and sheet A2.1 that changed the
door swing in the path of egress.
Page I I of 16 Plan Review Comments for Project # 60237493
Kruger Orthopaedics
NFPA 101, 2000 Version ASC
Relocation of ASC
20 El Verify or provide the rating of the 3d floor door and wall assembly that door # 300A is
part of to form a smoke barrier to provide the communicating space separation per
NFPA 10 1 Chapter 8.2.5.5
Approved 11/5/11 — Based on comment response that these doors are in a one hour
rated fire/smoke barrier wall.
21 El I Boiler room/mechanical room on roof that has direct access into stair well # 3, which
cannot have direct access to that stairwell per NFPA 10 1 Chapter 7.1.3.2.1 (d) and the
International building code Section 1022.3
Approved 1/30/11 — based on the door being eliminated from the stair well.
Mechanical:
22 El Modify the following pressure relationships per Table 2.1-2 of the 2006 FGJ:
(A)Room A324 sub sterile is required to be positive.
Approved 1/30/11 — based on this room being adjusted to a positive pressure
relationship, but less positive than the operating rooms.
23 N � How is smoke venting provided for anesthetizing locations per NFPA 99 Chapter 5-4.1.2
Approved 1/30/11 — based on comment response of sequencing.
24 El I How is humidity addressed for the operating rooms? WAC 246-330-505
Not Approved 1/30/11 — DOH will not require built in humidity, but CRS does need to
know what the policy and procedure is, if the humidity is out of the acceptable standard
ranges and how the facility would know if there were out of range.
Response: A humidity sensor will be added to each operating room. The humidity levels
will be monitored by the building management system and sound an alarm if humidity is
outside the acceptable standard range of 30%-60%0. If the alarms sounds, schedule
surgeries will be canceled or delayed unit an acceptable humidity level is reached.
Approved 4/2/12 — Based on comment response above.
25 El I How are pressure relationship maintained during off hours and weekends?
I WAC 246-320-505
Approved 1/30/11 — based on the AHU's running 24/7 per comment response.
Page 12 of 16 Plan Review Comments for Project # 60237493
Kruger Orthopedics
NFPA 101, 2000 Version ASC
Relocation of ASC
26 El I Provide the locations and rating for the pre and final filters for the ambulatory surgery
I facility meeting Table 3. 1 -1 of the 2006 FGL
(Found the Hepa filters in the supply diffusers of the operating rooms, but could not find
the filtering for the rest of the unit.
Approved 1/30/11 — based on sheet MO.02 and notes #12&13 on heat recovery
schedule.
Electrical:
27 El Provide a shared medical gas alarm for the operating rooms located in the same corridor
per NFPA 99 Chapter 4-3.1.2.2 (c) (reference elevations on sheet A7.2)
The recovery area is required to have one of its own.
Approved 1/30/11 — based on sheet E2.3B that added the area alarm panel.
2 8 El Provide sprinkler freeze protection in stair wells # 2 & #3 per NFPA 13 5-14.3.3
(reference sheet M2.01)
Approved 1/30/11 — based on a dry sprinkler head being used in the stairwells.
29 IE 1 Provide a physical separation between the normal power distribution and the emergency
distribution transfer switches on the first floor electrical room to prevent essential power
interruption by a failure in the normal distribution per NFPA 70 Article 517.35 (C)
(note this could be a hard wall partition of the room into two areas)
Approved 1/30/11 — based on wing walls being provided to form a separation.
30 El Recommend that the ice machine in room # A304 be placed on the critical branch of
emergency power as it will supply the ice for patients in hypothermic; shock and without
power the ice would not be dispensed from the machine.
Approved 1/30/11 — based on both the freezer and ice machine being provided with
critical emergency power.
31 El Atrium door hold open circuits NL 1 -3 need to drop out on fire alarm as this is a rated fire
i barrier. Are these hold open devices on a relay with the fire alarm? WAC246-330-505
(reference sheet E2.3A)
Approved 1/30/11 — based on comment response that the hold opens are controlled
by the fire alarm control panel that drops them upon building alarm.
Page 13 of 16 Plan Review Comments for Project # 60237493
16
Kruger Orthopedics
NFPA 10 1, 2000 Version ASC
Relocation of ASC
3 2 21 1 Provide two sources of outlet power in operating rooms # A320, # A319 and # A318 per
NFPA 70 article 517.19(A) that requires both normal and emergency power.
(reference sheet E2.3B)
Approved 1/30/11 — based on sheet E2.3B that added the normal power sources in
addition to the critical power.
3 3 Provide manual pull stations at the entrance to star well # 2 & #3 and at the exit/entrance
to the ASF per 1999 NFPA 72 2-8.2.2 and 2006 FGI 3.7-6.4.1 (reference sheet FAI.3)
Approved 1/30/11 — based on comment response and red lined FA drawing.
3 4 IHI Provide a ground wire that is the same size of the conductor in anesthetizing locations
per NFPA 99 Chapter 3-3.2.1.2 (5)(b)
Approved 1/30/11 — based on sheet E2.3B typical that shows the ground wire size.
35 El I What is the run time on the emergency power generator at full load with the fuel supply
allowance provided? WAC 246-330-505
Approved 1/30/11 — based on comment response that a 12 hour run time will be
provided.
Plumbing:
36 ON The faucet for the following hand washing stations must be a gooseneck with either wrist
blades or single lever controls per 2006 FGI 1.6-2.1.3. 1:
);;Taucet for sink # P2A convert to gooseneck device
Approved 1/30/11 — based on cut sheet received and comment response that the
faucet type above will be provided.
37 IE Provide a bed pan spray wand on any two of the recovery room patient toilets to facilitate
disposal of fluid waste in the recover area per 2006 FGI 3.7-2.5.6 (2)
Approved 1/30/11 — based on sheet P05 and comment response that added the bed
pan washers to two patient restrooms.
38 Provide reduced pressure back flow devices to each sterilizer, the instrument washer and
I for the Neptune docking bay hot and cold water connections
I per 2006 FGI 3.1-7.1.2.3 (3)(a) (reference sheet P05)
Not Approved 1/30/11 — Provide cut sheets on the Neptune docking station that verifies
Page 14 of 16 Plan Review Comments for Project # 60237493
4
Kruger Orthopaedics
NFPA 101, 2000 Version ASC
Relocation of ASC
that it has no water connections. Typical ones submitted all had water connections in
order to flush out the Neptune mobile unit.
Response: A hot water hose bibb connection through a reducedpressure backflow
prei,enter has been added to sen,e the Neptune docking station, see reWsed sheet PO.5
Approved 4/2/12 — Based on comment response above.
39 El I Provide a service isolation valve on the oxygen, Vacuum, nitrous oxide medical gas lines
on the horizontal branch lines as they come off of the vertical riser on the third floor per
NFPA 99 Chapter 4-3.1.2.3 (e) (reference sheet P05)
Recommend that the compressed air branch line also receive a service isolation valve.
Approved 1/30/11 — based on comment response and sheet P05 that added the
isolation valves.
40
The zone valve for the medical gas outlets in the recovery area cannot be located in the
same environment as the outlets per NFPA 99 Chapter 4-3.1.2.3 (d). But there is no other
location to locate it behind a door/wall where it is accessible in the egress route.
I Recommend that the location for the zone valve remain, but that a cross corridor door be
i added west of the ante room to form a separate environment.
Not Approved 1/3 0/11 — The zone valve needs to be environmentally separated from the
outlets, so that a fire fighter or staff does not have to go into the area of fire involvement
by oxygen fed fire to shut the gas off.
Provide alternate location.
Approved 4/2/12 — Based on zone valve being relocated into ante room # 332.
41 191 1 Note: The third required vacuum outlet is credited to the use of the Neptune units in
each of the operating rooms.
42 Provide a detail showing the air gap to the drain for the ice machine drain hose of a
minimum I" per International plumbing code Chapter 801.2
Approved 1/30/11 — based on sheet P06 that shows the air gap.
43 El Provide a one line drawing off all the medical gas manifold systems showing source
I valves, check valves, relief valve, and redundancy switch over device, gauges, master
alarm switch etc meet NFPA 99 Chapter 4-3 and figure 4-3.1.1.6 of the 1999 version.
Not Approved 1/3 0/11 — Provide the source valve location, check valves from tanks and
relief valve piping routing from them.
Page 15 of 16 Plan Review Comments for Project # 60237493
Kruger Orthopedics
NFPA 101, 2000 Version ASC
Relocation of ASC
Approved 4/2/12 — Based on modified section four of sheet P06 which shows the
devices.
44 El Specifications on sheet P 10 part 4.14 A speaks to using dental surgical vacuum. This
system is not a level 3 dental system and must meet all the requirements of a level I
medical gas system per NFPA 99 Chapter 4-3.
Approved 1/30/11 — based on sheet PIO update showing a level 1 system.
Compliance with the comments above provided by the Department of Health, Construction Review Services are necessaryfor thisfacility to meet
the requirements of the applicable licensing regulationsfound in the Washington State Administrative Code and associated references. These
comments do not relieve thefacilityfrom the responsibility to meet the requirements of any other applicable federal, state or local regulations.
In the event of conflicts between otherjurisdictions and these written comments, the most stringent shall apply.
Page 16 of 16 Plan Review Comments for Project # 60237493
I*
SNOHOMISH
HEALTH DISTRICT
WWW.SNOHD.ORG
November 21, 2012
Judy Wood
Practice Manager
Premier Orthopedic Group
21401 72 Id Ave W
Edmonds, WA 98026
Environmental Health Division
Subject: Proposed Premier Orthopedic Group, 21401 72 nd Ave W, Edmonds
Dear Ms. Wood:
A10 V 2 7 2012
DEVELOPMENT SERVICES
COUNTER
Your plans have been received; however the plans cannot be approved as submitted. The following
information is needed prior to further plan review.
1.- - A copy of an NSF listing with the manufacturer Vita--wmix was -included -with the -equipment -cut ---
sheets. However, no specific blender or model number was included. The model number for the
proposed Vita -mix blender must be submitted.
2. Only one refrigerator is included in the proposed cart plans and cut sheets. Is. any backup
refrigeration proposed? If so, where will the backup refrigeration be located? If backup refrigeration
is proposed, the manufacturer names and model numbers for the refrigeration must be submitted.
3. No finish schedule (final surfaces for floors, walls, ceilings, counter, and cabinets) was submitted for
the cart, three -compartment sink, mop sink, and dry storage areas. The finish schedule for these
areas must be submitted.
4. The plans submitted for the three -compartment sink/handwash sink and mop sink areas are not
legible. A larger scale floor plan must be submitted. The scale of the drawing must be no smaller
than % inch equals 1 foot, drawn to scale, showing the location of all equipment, plumbing fixtures
and the like. Please note that plans may be submitted in an unsecured PDF format. Cut sheets and
all other information may also be submitted in a PDF format.
Please note that prior to operating permit issuance and approval to open the new facility, after the
Health District plan review process is completed and construction is finished, the Health District permit
application process must be completed and a preoperational inspection must be conducted.
Please contact me if you have any questions. My office number is 425.339.5250 and my email address
is.rhoPPa(cD_snohd.or,q.
Since�,
r
5 R
obert A. Hopp
E viro
nvironmental ;ealth Specialist
Food Establishment Plan Review
"W 20 In 17,
cc: City of Edmonds Building Department
Brent French, IRS, Environmental Health Specialist
3020 Rucker Avenue, Suite 104 N Everett, WA 98201-3900 m tel: 425.339.5250 0 fax: 425.339.5254
9802 29h Ave. W #B1 02
Everett WA 98204
425-356-3372
425-356-3374 fax
_*M'
December 5, 2012
El 1041
Mr. Scott Shanks
First Western Development Services, Inc.
8129 Lake Ballinger Way, Suite 104
Edmonds, Washington 98026
Subject: Geotechnical Engineering Final Evaluation
Edmonds Medical Office BuildingYPremier Orthopedic
2140172 "d Ave West
Edmonds, Washington
Dear Mr. Shanks:
E3RA is pleased to submit this letter documenting the completion of the retaining wall constructed on
the north property thie at 21401 72d Avenue West in. Edmonds, Washington. The undersigned is the
design'engineer for the wall system and prepared the wall designs the project. As a result of this role,
we :also Rmctioned -as .-the Special Inspector. in accordance -with our -responsibilities -as Special
Inspector, we evaluated pile foundation construction, excavation stability for jackshafts and vaults,
backfill placement and compaction, drainage installation, and temporary and pen-nanent.erosion control
measures.
We conducted periodic visits during the construction of the project. During our visits, we observed and
documented the following:
Augercast Pilc� — We were onsite on a full time basis to monitor the installation of the augercast piles
which support the building. The piles were installed in accordance with the recommendations of our
ge otedhnical report for the project and the approved structural engineering plans.
Jackshaft Installation — E3RA monitored the installation of the elevator jackshafts for the project. The
jackshafts were installed in accordance with the plans and do not adversely affect the support
characteristics of the pile foundation system.
Soil Compactio — Fill was placed and compacted around the vaults in accordance with the project
specifications. Fill materials were approved and compaction monitored for fill materials placed in
association with curbs, gutters and utility installations in 72 "d Avenue West, as well as selected
locations on the site. Compaction was also checked for slab -on -grade and generator pad construction
and tests indicated that the project specifications were met
Subsurface Drainage Pipe — Perimeter drainage was installed in accordance with the project plans.
Erosion Control-Tempora - TESC was completed in accordance with current Best Management
Pracitces.for construction sites.
Erosion Control-Penrianent — All permanent erosion *control measures were in place at the time of the
final engineering inspection by the undersigned.
Page 2 December 5, 2012
Based on our observations, it is our opinion that the project has been constructed in general accordance
with the approved plans, the geotechnical report prepared by our firm dated July 5, 2011 and industry
practice for similar work.
We appreciate the opportunity to be of service on this project. If you have any questions regarding this
repoil or any aspects of the project, please feel free to contact our office.
Sincerely, TA
E3RA, Inc.
Dean M. White, P.E. 2773
-Engineer
Principal
I
ene : VultYPIOUMPOI TF1--)U lz--:5—fz-
I
/") C. I so�)
CITY OF EDMONDS
121 5th AVENUE NORTH * EDMONDS, WA 98020 (425) 771-0220 FAX'(425) 771-0221
www.edmondswa.gov
DEVELOPMENT SERVICES DEPARTMENT
December 7, 2012
Whidbey Island Bank
Nils Bajczuk, VP
19510 58h Ave W
Lynnwood, WA 98036
Re: Performance Frozen Fund Account #7000100565, Edmonds Medical
Building Associates, LLC at 2140172 nd Ave W, Edmonds WA
Dear Sir or Madam:
DAVE EARLING
MAYOR
The City of Edmonds hereby authorizes the release $88,973.60 from the above referenced
Performance Bond. The performance bond has been replaced with a maintenance bond
which must be held in place for a period of two years, until written City approval has
been sent authorizing release. All interested City departments have appro ved the release
of the Performance Bond.
Sincerely,
Marie Harrison
Senior Permit Coordinator
Cc: Applicant
File
L/Temp/DST's/MasterLeuers[ReleasePerformance02/01
Inqorporated August 11, 1890
Sister City - Hekinan, Japan
r, V 4 /- a
OV 4b 0:8-
0
Date Expires
Account Number
(J A T City of Edmonds
121 5"' Avenue North - Edmonds WA 98020 - (425) 771-0220 Fax (425) 771-0221
Website: ww%v ci.ednionds.\vams
I — — — __ DEVELOPMENT SERVICES DEPARTMENT
��_ C\
sc)�) Planning - Building - Engineering
PERFORMANCE FROZEN FUND
Edmonds Building Permit No. BLD20110815
Project Address 21401 72ND AVE W EDMONDS WA 98029
Owner/Deveioper FoMnNnS MFnTr8i BUTI-DING ASSOXI-ATES, LLG
With reference to the above identified project, this will certify that this Banking Institution has
a frozen fund account/savings account (or loan) for the above -referenced developer/owner for the
project so identified. In consideration of the permitted development of the property this institution
hereby agrees that it will freeze the sums of money for the indicated site improvements pending written
authorization for release of said funds by the City of Edmonds in the amount of
$ 88,973.60
The total sum indicated will be withheld by this Banking Institution from any disbursements of
any kind until written authorization has been received by the institution from the City of Edmonds to
release the sum of money indicated by the written authorization from the City.
The design, location, materials and other specifications for the indicated site improvements are
those required by the City of Edmonds and appear in the above -referenced Edmonds building permit
file and are in compliance with the Edmonds Community Development Code of said City.
In the event the owner/developer fails to complete the indicated improvements within
six X*Xk�(months, (not to exceed 24 months) the City of Edmonds may demand,
and the institution shall make� payment to the City of said funds so that the improvements can be
installed or completed immediately to City standards. The institution shall not be liable to the owner
for any disbursement of said funds to the City of Edmonds.
It is hereby specifically agreed by and between the parties hereto that in the event that any legal
action must be taken to enforce the provisions of this agreement or to collect said frozen fund, that the
prevailing party shall be entitled to collect its cost and reasonable attorneys' fees as a part of the
reasonable costs of securing the obligation hereunder. In the event of settlement or resolution of these
issues, prior to the filing of any suit, the actual costs incurred by the City, including reasonable
attorneys' fees, shall be considered a pail of the obligation hereunder secured. Said costs and
reasonable legal fees shall be recoverable by the prevailing party, not only from the proceeds of this
frozen fund account, but also over and above said body as a part of any recovery in any judicial
proceeding, in addition to recovery of the funds.
LAB U i I d i ng N ew Fo I d e r 2 0 1 Worm s�13 ON DPer forma nce Frozen. doc6/29/2 0 11
0 %
City of Edmonds Performance Frozen Fund Account
Page Two
WHIDBEY ISLAND BANK
Finan tion
OffleeK itle
�ILS BAJCZUK, V.P
19510 58TH AVE W
LYNNWOOD WA 98036
Mailing Address
7000100565
Account Number
EDMONDS MEDICAL BUILDING ASSOCIATES, LLC
Owner/Developer/Principal
L
PrintName C SCOTT SHANKS, MANAGER
8129 LAKE BALLINGER WAY
EDMONDS WA 98026
Mailing Address
(425) 329-0848
Telephone Number
FINANCIAL INSTITUTION ACKNOWLEDGEMENT
STATE OF WASHINGTON)
) ss
COUNTY OE566rfilsh)
On this
day of b?CfMbP(' —, Poll 3 before me, the
undersigned, a Notary Public in and for the State of Washington, duly commissioned and swom,
personally appeared N1,16 &-)C-ZL)1C- tomeknowntobethe Vice Anj"'qn�
of W byA -f6[cJ6aj0k _, the corporation that executed the foregoing instrument, and
acknowledged the said instrument to be the free and voluntary act and deed of said corporation, for the
uses and purposes therein mentioned, and on oath stated that h r- -was
authorized to execute said instrument and that the seal affixed is the corporate seal of said corporation.
WITNESS my hand and official seal hereto affixed the day and year first above written.
LLIONDA S. STINNETT
OT
NOTARY PUBLIC
S T T�
TATE OF WASHINGTON
C C M
OMiMiSSION EXPIRES
24. 2015
4,OA ZLJ�
NOTARY PUBLIC in and for the
State of Washington, residing at
L Iio r) waod
LABuilding New Folder 2010\Forms\BONDPerformanceFrozen.doc6/29/2011
0
City of Edmonds Performance Frozen Fund Account
Page Three
DEVELOPER/OWNER ACKNOWLEDGEMENT
STATE OF WASHINGTON
ss.
COUNTY 0
On this day of before me, the under -signed,
a Notary Public in and for the State of Washington, duly commissioned and sworn, personally appeared
torneknowntobethe A '-n Ar-1 e%-.p -0 fc!�"
"hi �,-,Arp ]4ff=-. LIA2, the general partnership that �Jed' the foregoing instrument, and
acknowledged the said instrument to be the free and voluntary act and deed of said partnership, for the
uses and purposes therein mentioned, and on oath stated that
Lwas authorized to execute said instrument.
WITNESS my hand and official seal hereto affixed the day
NANCI LEE BUSBY
NOTARY PUBLIC
STATE OF WASHINGTON
COMMISSION EXPIRES
DECEMBER 31. 2011
year
JaIC in`tnM br'the State of
residing #t I
LABuilding New Folder 2010\Forrns\BONDPerformanceFrozen.doc6/29/2011
0
I]
L
OLYMPIAN PRECAST INC.
wwwolyprecast.com
19150 UNION HILL ROAD TEL (425) 86& 1922 POST OFFICE BOX 539
REDMOND, WA 99053 FAX: (425) 8611-1400 REDMOND, WA 98073-0539
Pr,"RiZ4�— 6WUPMt'6
044-tr - pre
t O'V" _
QUALITY CONTROL PROGRAM
Revised 1122107
MAR 23 2012
DEVELOPMENT SERVICES
COUNTER
Our Quality Control function is to make sure that the product conforms to specification and to
prevent deviations from correct procedures during the production process. The quality Control
Department is supervised by Donald Frazier. . Mr. -Frazier has been employed in the
precast/prestressed concrete industry since 1970 and has been a Quality Control Supervisor
since 1980. The Quality Control Department reports to the vice President, Kevin C. Jewell.
On a typical day our routine involves: Checking all molds for correct configuration and
dimensions against approved shop drawings. Insure that adequate provisions are providedfor
hardware placement in products and all other miscellaneous items such as reglets, inserts,
electrical boxes and block -outs. We also assure that molds are properly restrained so as not to
let product exceed tolerances. If mold passes our inspection it is then O.K.'d with a green tag
(enclosure #1) to let production crew know that they can proceed. In times of low prodUCtion
when only one (1) quality control inspector is checking molds, the green tag is deletted and mold
inspection results are relayed verbally to crew leadman. After passing mold inspection the
product number is checked off the daily production sheet (enclosure #2).
After the casting crew has set up the mold with the rebar and all embeds in place, the mold is
again checked for correct placement Of reinforcing and embeds.
Each individual product is checked after removal from mold for correct configuration and
dimension. Each piece is marked with a panel number, Olympian Precast ob number and
casting date on an unexposed surface. Occasionally, there are products which have all
exposed surfaces. In that event, the product is marked by a tag. As a double check, for
multiple inspectors, we also circle the panel number on our Daily Production Sheet after it is
checked.
Any discrepancies found are noted on daily production reports and followed up with a red tag
(enclosure #1) attached to product and memos (enclosure #3) distributed throughout the plant,
to appropriate parties. After the discrepancy is corrected, the supervisor inspects the correction
and if satisfactory, also initials the memo and files the initialed memo.
Testing carried.out on a daily basis includes concrete testing of cylinders, slump, and air content
reported on a daily running log (enclosure #4). For Cem-Lite production (GFRC), slump, glass
content and a V-0" square sample boa ' rd is made daily for each job in production. We make 4"
x 8" cylinders for backing concrete, 4" cubes for small aggregate facing mixes, and cut 2" x 12"
strips out of a sample board for Cem-Lite flexural strengths. Each different type of produict has
its own reporting sheet (enclosures #5 and #6). Test results not meeting specification are
reported to the vice President and Superintendent.
Concrete Batching Mixes are reported in half sack batch mixes (enclosure #7) for the batch
plant operator. The operator. keeps inventory of his daily batch usage (enclosure #8).
Each individual piece of hardware used either in our product or by the erection crew is given a
piece number and a drawing made on an 8 1/2" x 11 " card (enclosure #9) for shop fabrication.
Jigs are then made in our shop as needed -and Quality Control does an overall check of
material. Stud welding is checked at the beginning of each operation by the Leadman assigned
to the weld shop. Special note: Any hardware devices with moveable components must be
pre-set in the formwork and securely tied to prevent movement of those moveable components.
Forms (enclosure #10) are kept in the Weld shop until completed and then transferred to Quality
Control Files.
Frames for ' GFRC panels are fabricated and checked for configuration and dimensions and
correct welds the same as all products cast.
Our plant's main source of sand and aggregate is from Manufacturers Minerals and Cadman
Gravel. Many other specialty aggregates are available and brought into the plant in bulk or
sacked depending on quantity. Sieve analysis is many times provided by the supplier or done
here at eh plant and recorded in each job file that eh aggregate is used for (enclosure #11 and
#12).
OLYMPIAN PRECAST, INC.
EQUIPMENT
Quality Control Area -Include:
0 Office in main production area
9 Testing laboratory
0 Sample cast space on Mixer Deck
& Storage Room
0 Sample Curing Room
a Cem-Lite Testing Room
Other Equipment:
0 Forney 400,000 lb. Capacity concrete testing machine.
0 M.T.S. Tensile Tetting Machine with 1,100 lb. Load cell capacity and recorder.
a All necessary small hand tools
0 5,000 lb. Capacity dynamometer.
a 6 x 12 steel cylinder molds.
0 4 x 8 steel cylinder molds
0 Capping compound melting pot.
9 4" cube molds and 2" cube molds.
50 lb. Capacity dial scale
1,500 gram scale.
"Press-ur-Meter" air entrainment tester.
Slump cone.
a Temperature recorders.
0 Access to all ASTM, ACI, AWS and PCI reference literatu
re.
71
OLYMPIAN PRECAST, INC.
PRODUCTS
Precast Concrete; Including Spandrels, Wall Panels, Columns, Beams, Lintels and Floor
Slabs, etc.
Glass Fiber Reinforced Concrete: - GFRC are products manufactur ed using a
cementlaggregate slurry, reinforced throughout with alkali resistant glass fibers. .
Stone Faced Panels: - Attached to a steel stud frame with our patented Oly mipian (Donaft)
connection.
MATERIALS
Water
Cement
Aggregates & Sands
Rebar
Lightweight Aggregate
Advacast 530
Micro Air
Fritz 5
Fiberglass
Polymer
Steel Studs
Miscellaneous Iron
Galvanized
Stainless Steel
Nelson Studs
Weld Wire Fabric
Prestressing Strand
Steel Tubing
High Strength Bolts
ASTM
C-94
C-1 50
C-33
A-615
C-330
C-260
C-260
C-494
C-754
A-36
A-1 53
A-564
A-20,A-1 08,A-370
A-1 56
A-416
A-513 or A-500
A-325
COMMENTS
Potable well at plant site
Type I and Type III
Usually 718" and smaller
Usually #8 and smaller
Expanded Shale fines through
Super Plasticizer
Air Entrainment
Super Plasticizer
Alkali Resistant Glass Fiber
Curing Aid (GFRC)
Framing for GFRC Products
Angles and Plates used for bldg. connections
Ang les and Plates used for bldg. connections
Angles and Plates used for bldg. connections
0lLLubuNL
"Job No P.O. No.
REJECTED
Part No.
Part'Name: C�
0 No. of Pieces:- -
Reason.-
-Disposition -
Inspector: - Date:
OLYMPIAN PRE -CAST, INC. -
2
10
r77'.'
Production For:
Page I of 2
Bjorback, Leif
From: Bjorback, Leif
Sent: Friday, March 23, 2012 11:52 AM
To: 'Jim'
Cc: macs@pennonconstruction.com; Joe Sullivan; jeffs@pennonconstruction.com; Scott Shanks; Chuck
Morris; Lawler, Patrick
Subject: RE: Premier Ortho - OPI Quality Control
Hi Jim,
Thank you for the QC information from Olympic. No further documentation is needed li-y the city
for testing of the panels. As we discussed, however, the installation of the panels will still require
special inspection. I
Regards,
Le�f -3jdi-tvwk,
Assistant Building Official
'City of Edmonds
(425) 771-0220
----- Original Message -----
From: Jim [mailto:jimw@ddgarchitects.com]
Sent: Thursday, March 22, 2012 4:43 PM
To: 13jorback, Leif
Cc: macs@pennonconstruction.com; Joe Sullivan; jeffs@ pen nonconstruction.com�@ Scott Shanks; Chuck
Morris
Subject: FW: Premier Ortho - OPI Quality Control
Hi Leif,
I am following up on our phone conversation this afternoon. -Here is the QC information form
Olympian Precast substa'ntiating the material testing that they conduct. Do you want to see copies of
the concrete strength testing? Let me know if you still have questions.
Jim Wieben
From: Clarke Jewell [mailto:ClarkeJ@olyprecast.com]
Sent: Thursday, March 22, 2012 4:06 PM
To: Jim
Cc: macs@pennonconstruction.com
Subject: Premier Ortho - OPI Quality Control
Jim, following up on your question this afternoon.
I have attached Olympian's quality control program. All three organizations that Olympian is plant
certified have strict requirements that Olympian abides by to provide our own in house testing by
qualified personnel. The City of Seattle certification allows Olympian to conduct our own testing
without the need for special inspection on each individual project.
3/23/2012
Page 2 of 2
Please attached link below describing the APA Plant Certification program in more detail:
htt�://www.archprecast.org/plantcertification.htm
If you have any questions regarding the APA certification program please feel free to contact the APA Executive
Director @
Fred McGee
6710 Winkler Rd, Suite 8 Fort Myers, FL-33k9
Phone: 239-454-6989
Email:info@archprecast.org
Let me know if you have any additional questions.
Clarke Jewell
Project Manager/ Estimator
Olympian Precast, Inc.
APA Plant Certified
www.olyprecast.com
T: 425-868-1922
3/23/2012
INC
*Z-O cel
MEMO
DATE: February 15, 2012
TO: JIM WIEBEN, SCOTT SHANKS
FROM: Chuck.Morris
RE: Concrete breaks for piles # 722 and 723
As you know we have gotten some inconsistent and low concrete breaks for the piles noted
above. The pile capacity is typically not governed by the concrete strength. The governing
factures are typically the soil pile interface, both end bearing and side shear. This is the case
for the piles on this project. I have re -run the pile as a concrete colun-m with the concrete
strength as the governing element for the capacity of the pile. I find that with the concrete
strength of t'c= 3000psi the conerete.column will provide a greater capacity than the pile
design. Therefore the average concrete strength of f c= 3390 psi is acceptable.
Structural Engineers *
' 80 Nickerson St.
Suite 302
Seattle, WA
98109
(206)285-4512(V)
(1200) 285-0018(F)
Page I of 2
113jorback, Leif
From: Mac Sele [macs@pennonconstruction.com]
Sent: Wednesday, February 15, 2012 5:34 PM
To: Bjorback, Leif
Cc: Scott Shanks; Jeff Still; Joe Sullivan
Subject: Premier Orthopedic - Special Inspections Low Breaks at Piles 722 and 723
Follow Up Flag: Follow up
Flag Status: Flagged
Leif,
Attached is a memo from our structural engineer in response to the low concrete break reports
associated with piles 722 and 723. Please review for your records. Please let us know if you have any
questions or concerns. Thanks,
Mac Sele, LEEDOAP
Pennon Construction Company, Inc.
5303 First Avenue South, Suite 100
Seattle, WA 98108
206.418.0235 ext. 103
206.510.3575 cell
206.418.0237 fax
www.pennonconstruction.com
This message may contain confidentiaL andlor priviLeged information. If you ore not the addressee or
authorized to receive this for the addressee, you must not use, copy, discLose, or take any action based
on this message or any information herein. If you hove received this message in error, p�eose advise the
sender immediateLy by repLy e-moiL and deLete this message.. Thank you for your cooperation.
From: Jill Rouse [maiIto:JRouse@MAYESTESTING.com]
Sent: Wednesday, February 15, 2012 3:03 PM
To: Chuck Morris; City of Edmonds; Jeff Still; Jim Weiben; Mac Sele; Scott Shanks; Todd Wirtz
Subje(t: L11583 Premier Orthopedic Group Building - Inspection Report 2/9/12
Good afternoon -
Please find attached for your records our inspection report(s) for the Ll 1583 Premier
Orthopedic Group Building project.
Thanks,
Jill Rouse
Account Coordinator
f rouse((Dmayestesting-com
MAYES TESTING ENGINEERS, INC.
20225 Cedar Valley Road
Suite 110
Lynnwood, WA 98036
p 425 742 9360
f 425 745 1737
www.mayestesting.com
3/1/2012
- ?_A -)I)
;2- /-1-0 / 7
7A
110,
PREMIER ORTHO PRE -CON - 12/19/2011 'Zoil—
NAME
PHONE EMAIL
4 f
T e, 4,
--39c, —5-1 fD
Cd�,
SCL2 ol
772,o
d2
AA
LA.)
_q?_S--77S_-
2,6(,- - -?55 - -?3
ej �ev-h Iv,, c c
11#1
t x )
MkA_��
1-740-TT
-5.�JANYJ-�7
'D,�__c,,,,\ wc-) v-�-
Mosc-
tiz
afe:�d
4-7j-. -m.ovzo
nituoneU E
edja=Yt uld .4
MAO o ci edkmdc.
wd, af
Rjw,&,L-
ctew
Is
I
�9-
Letter of Transmittal
January 30, 2012
RECEIVEI)
JAN 30 2012
DEVELOPMENT SERVICE,'
COUNTER I
Project Info:
4 Washington State Department Of
iHealth
Construction Review Services
3 10 Israel Rd. SE
Tumwater, WA 98501
PO Box 47852
Olympia, Washington 98504-7852
www.doh.wa.gov/crs
tel. 360-236-2944
fax. 360-236-2901
CRS# 60237493
Project
21401 72nd Ave W
Kruger Orthopaedics
location:
Edmonds, WA 98026
NFPA 101, 2000 Version ASC
Suite 3A
Relocation of ASC
Local Permit #:
Key People:
Assigned DOH Steve Pennington
Reviewer: steve.pennington@doh.wa.gov
Facility Kruger Clinic Orthopaedics, PLLC
Facility Contact:
Same As Administrator
Administrator: Marilyn Degan
21600 Highway 99 Ste 130
Edmonds, WA 98026
(425) 774-2637 x.
X.
judy@krugerortho.com
Architect Architectural Werks Inc
Local AHJ:
City of Edmonds
Engineer: Janet Monda
Leif Biorback
12020 113'h Ave NE, Ste 2 10
Kirkland, WA 98034
(425) 823-2244 x.
(425)771-0220 x.
janet@awerks.com
Bjorback@ci.edmonds.wa.us
Consultant: Pennon Construction Company Inc
Consultant:
Bellevue Mechanical Inc
Mac Sele
Larry Boyer
5303 1" Ave S Ste 100
1331 120t' Ave NE
Seattle, WA 98108
Bellevue, WA 98005
(206) 418-0235 x.
(425) 679-5931 x.
macs@pennonconstruction.com
larry.boyer@bellevuemechanical.com
Contact: SME Inc of Seattle
Contact:
N/A
Dallas Anderson PE
828 Poplar PI S
Seattle, WA 98144
(206) 788-3829 x.
X.
dallasa@smeincofseattle.com
Copies To:
Local AHJ: City of Edmonds
0
DOH Child Birth Center Licensing
Architect / Engineer: Architectural Werks. Inc
DOH Office of Accommodations & Res. Care Survey
Z
Consultant: Pennon Construction Company Inc
DOH Office of Investigations & Inspections
9
Consultant: Bellevue Mechanical Inc
E]
DSHS, Div. Of Alcohol & Substance Abuse
Z
Contact: SME Inc of Seattle
El
E
DSHS, Aging & Adult Services Admin.
L&I, Bill Eckroth, Electrical Section
F�
Contact: N/A
El
L&I, John Harvey, Factory Assembled Structures
E
CRS File
Page I of 15 Plan Review Comments for Project #60237493
0
0
Data Certificate:
Facility Name: Kruger Orthopaedics
Site Address: 21401 72nd Ave W
Edmonds, WA 98026
Estimated Date of Occupancy: 12/2012
Licensee UBI#: 601850391
Critical Access Facility: E] Yes E No
Occupancy B
Construction
2-B
Applicable Code: 2000 NFPA 101
Group:
Type:
rA
r04
Number of Current:
N/A
Added:
Removed: Total:
Beds:
Automatic Fire Sprinkler System: Z Yes
No
Type 13
Automatic Fire Alarm System:
E Yes
F� No
U
ot
Compartmentation req'd:
ZYes
E]No
Smoke Control System Provided: [I Yes ZNo
Wo
04
Special Delayed Egress Control:
El Yes
��No
Location:
Certificate of Need Required:
0 Yes
E]No
CON Approval Granted: 0 Yes ONo
CON Number:
Number of units: Private occupancy: Two person occupancy:
Based on size of rooms used for sleeping Residents
0
Based on size of common rooms Residents
Maximum allowable licensable beds:
Qualifies for Assisted Living Funding Program 0 Yes ONo Number of qualifying units:
This facility will be using general anethesia.
The data above is based on the information presented to CRS. Any change in the facility or facility program that
causes the above information to be incorrect is subject to review by CRS. Approval for construction is not
approval for licensure. A copy of the facility data certificate will be sent to the licensing agency.
Page 2 of 15 Plan Review Comments for Project #60237493
0 0
Project Status:
- Authorized to Begin Construction —
- Comments Not Approved —
This project is not approved for use or licensure. The construction documents have been reviewed and
construction can begin, subject to construction permittingfrom the local building official.
This project will not be approved until the comments labeled as "not approved" have been resolved by
providing a written response to each of the comments. When referencing drawings or attached materials,
provide sheet or page #, revision # and date as applicable. Additional comments may follow based on design
team response and site inspections may be required to verify compliance.
Please note the following:
The stamped "Authorization to Begin Construction" drawings will be delivered to the Facility
Administrator. These shall be kept available on site for inspection during construction and post
occupancy survey.
• Any changes/deviations (incl. change orders or addenda) from the approved documents must be
submitted to the Department for review and approval.
• Beginning construction prior to resolving the attached comments will constitute facility
acknowledgement that you are proceeding at your own risk.
• Please include your CRS number on all communications to Construction Review Services.
PROJECT CLOSE-OUT REQUIREMENTS You must notify the department when construction is
complete by completing the following steps:
v,' Verify that you have resolved all of the comments on this form and have submitted any revisions
V Complete the Online Notification of Construction Completed at:
http://static.doh.wa.2ov/hs(ia/fst/CRS/pink eard.htm
Email or fax the assigned reviewer (see page 1) a copy of the approval from the local building
department (final permit approval or certificate of occupancy); and
-/ Email or fax the assigned reviewer a floor plan showing the scope of work.
You will be recommended to Licensim, when you have completed these items.
You can monitor project status at www.doh.wa.jpov/crs-
Page 3 of 15 Plan Review Comments for Project #60237493
Technical Assistance (TA) Comments
U
TA —July I 1", 2011
Attendees:
Steve Pennington (steve.pennington@doh.wa.gov) - Department of Health
Marilyn Degan - Premier Orthopedics
Janet Monda — Architectural Werks
Mae Sele — Pennon Construction
Design and Construction team
The preceding are preliminary comments provided as information and for use preparing the
construction documents. These preliminary comments may be revised during subsequent
submissions/conferences. Additional preliminary comments may be made during subsequent
submissions.
Items Received: Sketch
TI Contact Certificate of Need at (360) 236-2955 to confirm what actions are needed with the
relocation of your Ambulatory Surgery facility.
LIFE SAFETY:
T2 The main entry stair is a communicating space that the life safety code will look at more
restrictively and will require a separation of the floors environmentally with a smoke barrier
separation on the third floor in a fully sprinklered building. The doors on the third floor leading
into the vestibule will need relytes in order for the public to ascertain whether there is an risk in
using this exit way in the event of a fire.
T3 The wall separating the ASF from the clinic will need to be a fire partition as noted in the
Washington state amendments to the International building codes in Chapter 422.
T4 The wall around the medical gas storage/manifold room on the I st floor level of the parking garage
will be required to have a one hour fire barrier surrounding it.
T5 The number 5 gauss line will have to be contained within the MRI area, so that it does not affect
ASF patients or the public using the exit access corridors.
T6 Doors must swing in the path of egress where there are 50 or more occupants using the allowance
of 100 square feet per person.
Page 4 of 15 Plan Review Comments for Project #60237493
Architectural:
T7 Drugs must be stored in a secured location, including refrigerated medications.
T8 Patient toilets rooms must have doors that prevent entrapment.
T9 Rooms that a clean or dirty with required pressure relationships should be provided with door
closers to ensure that the pressure relationship is always maintained.
T10 Public corridors are required to be a minimum of 5 feet wide except where stretchers are moved
and then an 8 foot wide corridor is required.
TlI A washable drop ceiling is permitted in the surgery corridor as long as it is clipped or gaskets or
uses a ceiling tile that is a minimum of one pound in weight per square foot and sits flat in the
ceiling grid.
T12 Clearances for the PACU stations are 5 feet between gurneys and 4 feet off of a wall.
T13 Patient restrooms supporting the PACU would need a means for disposing of fluid waste, a spray
wand would be acceptable.
T14 A clinical flush sink is required for the decontamination room.
T15 The soiled utility room could be used as a soiled holding space for the Neptune unit docking
station, soiled linen storage and infectious waste storage.
T16 The billing office being open to the corridor is of a concern if they have any substantial amount of
fuel load from files above that of a normal hazard level for a business occupancy.
Mechanical:
T17 A level one medical gas system is required, with a duplex vacuum pump and redundant oxygen
supplied from a fully piped manifold gas systems.
T18 Only two vacuum outlets per operating room will be required to be piped in, as the Neptune unit
will satisfy the requirement of the third vacuum outlet.
T19 A medical gas zone valve is required outside of each operating room and one for the recovery
room is also required outside of the outlets environment.
Page 5 of 15 Plan Review Comments for Project #60237493
0
0
0
U
T20 Inferred controls for the scrub sink and faucet is acceptable as long as the faucet is a gooseneck.
Handle controls for hand -washing can be either wing handles or single lever.
T21 A hot water re -circulating loop must be provided for the domestic hot water.
T22 A fully ducted supply and return air system is required for the ASF.
T23 Insulation of ducting should be exterior mounted to allow cleaning of ducting.
T24 Low wall returns on the opposite walls and as far apart as possible shall be installed in the
operating rooms. Larninar, non aspirating diffusers shall be used on the supply air.
T25 Air exchanges in the operating rooms shall not exceed 20 ACH. Any amount over the 20 ACH
would need to be reviewed and supported by an ICRA, studies and consistent with
recommendations from ASHRAE, CDC, NIH.
T26 Back flow protection for the building and any equipment connected to the domestic water system
will be required.
Electrical:
T27 An emergency power generator systems shall be provided meeting NFPA I 10 and NFPA 99.
T28 Security of the generator and fuel tank shall be provided.
T29 A remote generator enunciator shall be provided at a nurse station where it can be monitored
during business hours.
T30 The branches of emergency power shall be provided, consisting of the Life safety branch, critical
power branch and a equipment branch. The associate devices shall be placed on those branches as
permitted by code.
T31 All outlets shall be hospital grade.
T32 Medical gas area alarms shall be provided for the PACU and the operating rooms.
T33 Lighting in the operating rooms shall have lens and gaskets.
T34 All patient bed locations shall be served from two sources of power.
Page 6 of 15 Plan Review Connnents for Project #60237493
0
0
0
U
T35 Provide exit signs that clearly delineate the required exit pathways.
T36 Provide exit access pathway lighting.
T37 Surgery suites will need a code blue emergency call button.
Intake conference 11/15/11:
T38 How will the generator be fueled when there is no access within the property of the owner?
WAC 246-330-510
T39 How are the .5 guass lines for the MRI contained away from public area's.
T40 Structural engineering buy off on overhead booms for lights or service must be provided.
T41 Freeze protection in exterior stair must be provide for wet sprinkler systems per NFPA 13
T42 Revise life safety plan to show travel distances to the two require exit stairs that meet NFPA 10 1.
T43 Smoke venting for anesthetizing locations to be provided per NFPA 99 Chapter 5.
T45 The life safety branch of the emergency power system shall provide power to exit sign, exit access
pathway lighting and services required to be on the life safety branch per NFPA 99 Chapter 3-4.
Page 7 of 15 Plan Review Comments for Project #60237493
Krug�r Orthopaedics 0
NFPA 101, 2000 Version ASC
Relocation of ASC
Plan Review Comments:
>
i Z
FE%
General:
Two complete plans and specifications for the fire alarm system installation or
modification shall be submitted for review and approval prior to system installation.
The department reserves the right to defer plan review and inspections to the local
authority having jurisdiction (AHJ). Plans and specifications shall include, but not be
limited to, a floor plan; location of all alarm -initiating and alarm -signaling devices;
alarm -control and trouble -signaling equipment; annunciation; power connection; battery
calculations; conductor type and sizes; voltage drop calculations; name, address, and
phone number of the agency receiving off -premises transmission of alann; and the
manufacturer, model numbers, and listing information for all equipment, devices, and
materials. InconlDlete Dlans and Mecifications will be returned without review. Plans
and specifications may be submitted separately from construction documents during the
construction of the project. For small renovation projects in which devices are only to be
relocated or very few devices are to be added, provide two plans that shows the
relocation of devices which may be submitted for review in lieu of the above
requirements. This information can be included on the electrical or architectural plans.
Verify with Department staff to determine if the scope of your project meets this criteria.
Section 907.1, International Fire Code
Approved 1/30/11 — based on a pull stations also being located at stairwell # 2 door
on level 3 and a pull station being located at the front entry door to the ASF per red
lined drawings FAI.3
2 IF] 1 Two sets of sprinkler system working plans shall be submitted for review and approval
before any equipment is installed or remodeled. The department reserves the right to
defer plan review and inspections to the local authority having jurisdiction (AHJ).
Deviation from approved plans will require permission. Plans and specifications,
including hydraulic calculations, that are incomplete or are not stamped by a Washingto
State Licensed Fire S-Prinkler Contractor, will be returned without review. Plans and
specifications may be submitted separately from construction documents during the
construction of the project. For small renovation projects in which heads are only to be
relocated, a plan that shows the relocation of devices can be submitted for review in lieu
of the above requirements. Section 903. 1, International Fire Code
(A)Note: Sprinkler heads in the operating rooms are required to be the clean room
concealed type to meet the monolithic ceiling finish requirements of the 2006 FGL
Page 8 of 15 Plan Review Comments for Project # 60237493
Krug�r Orthopaedics
NFPA 101, 2000 Version ASC
Relocation of ASC
3
Approved 11/5/11 — Based on cut sheets provided that meet the above requirement.
(B)Provide fire sprinkler protection in the stairwells to meet the minimum of one at the
top of the stair shaft and under the first landing above the bottom of shaft per NFPA 13
5-13.3 (reference sheet 4 of 4 of Patriots drawing)
Approved 11/5/11 — Based on cut sheets provided and response that the heads will
be provided.
Contact the Certificate of need program with the Department of Health at (360) 236-2955
to process the change of location for your Licensed Ambulatory surgery facility.
Response: Judy Wood has contacted DOH staffper SP recommendation. It was
suggested to re -contact and begin in 2 months.
4 IZ Provide in the functional program per 2006 FGI 1.2-2.1 the following:
(a)What types of procedure will be performed at the new site.
(b)Where are medications stored and secured. This would also include securing of
refrigerated medications.
(c)Is the ice machine conveniently located for emergency use for patient in
hypothermia?
(d)How/ where are laundry services provided?
Approved 1/30/11 — based on comment response and updated functional program.
5 El How will continued access be provided to the emergency power generator for fuel
re -supply with no direct access from on -the -property is provided? WAC246-330-510
(reference sheet A-101)
6 El
Approved 1/30/11 — based on response that a fuel fill line will be added where the
fuel truck can fill the generator tank from the front of the building.
Provide steel bollard protection from vehicle damage to the generator and fuel tank from
the neighboring parking lots per International Fire Code 3404.4.6
Locate these bollards no less than four feet on center per lFC Section 312.
Approved 1/30/11 — based on drawings that show the bollards installed.
7 El Provide an exterior door or access next to the storage room on the east wall of the first
floor to provide easy access to the generator for maintenance and testing purposes per
NFPA I 10 Chapter 6. (reference sheet A- I 11 grid line H2/3)
Page 9 of 15 Plan Review Comments for Project # 60237493
Kruger Orthopaedics
NFPA 101, 2000 Version ASC
Relocation of ASC
El
MEN "M
10 IHI
I I El
12 El
13
Approved 1/30/11 — based on a new door out of the storage room that accesses the
generator.
Provide a detail for the concrete service pad and seismic restraint for the emergency
power generator and how clear service access will be provided per the manufacturer
around the unit. WAC 246-330-505 (reference sheet C2)
Approved 1/30/11 — based on drawings section that shows the concrete pad and
seismic notes for anchoring.
Note: On fire rated doors that are designated to have door protection, the maximum
height of an non -listed applied panel is 16 inches above the bottom of door
per NFPA 80 2-4.5 unless the door comes as an approved assembly with the door
protection. Revise specifications per the above. (reference note # 7 on sheet A9. 1)
Approved 11/5/11 — Based on comment response and modification of the door
schedule to meet the above requirement on fire rated doors.
Provide door closers on the following doors to maintain the required pressure
relationships per Table 2.1-2 of the 2006 FGL
A307A, A313A, A313A, A315A, A302A, A325A, A324A and A324A
(reference sheet A2. 1,A9.1 &A9. 1 B)
Approved 1/30/11 — based on sheets AMB that added the door closers.
Provide verification that the .5 gauss line for the MRI is contained away from public
areas per 2006 FGI 2.1-5.5.5.8 (2) in the Lobby/Latte area. (reference sheet A2.4)
Approved 11/5/11 — Based on sheet A2.6 dated 11/30/11 that shows the .5 gauss lined
contained.
Provide a structural engineered sign off on the support systems for the surgical lighting
system per WAC 246-330-505 (reference sheet A6.3 section# 11)
Approved 11/5/11 — Based on sheet S8.02 that provides an engineered support
system.
El Provide details showing how the vertical and horizontal joints in the hygienic wall
covering wainscot in the operating rooms will be joined to form a monolithic finish per
2006FG13.7-5.2.2.4(3) (reference sheet A9.2 and A6.1)
Page 10 of 15 Plan Review Comments for Project # 60237493
0
Krugqr Orthopaedics
NFPA 101, 2000 Version ASC
Relocation of ASC
0
Not Approved 1/30/11 — The vertical weld joint is acceptable, but the "J" mold top
start edge trim is not acceptable, as it does not form a good seal against the wall
protection. A solid surface trim piece or just a caulked top of wall protection to the
wall is acceptable. Provide alternate top trim detail.
14 LL<J I Provide a stamped and signed plumbing drawing by the engineer of record
per WAC 246-330-505
i Approved 1/30/11 — based on signed plumbing drawings received.
Life Safety:
15 ON Provide a 45 minute rated fire door to the medical gas storage room that is one hour rated
per NFPA 101 Chapter 8.2.3.2.3.1 (2) (reference sheet A-119 and A-111)
Approved 1/30/11 — based on comment response that added the door rating.
16 El Provide a two hour fire barrier with a 90 minute rated fire door around the elevator
1 equipment room per the International Building Code Section 3006.4
(reference sheet A-1 11)
Approved 1/30/11 — based on drawing that shows the 2 hour rating.
17 El Provide a one hour fire barrier around the Electrical service room on the first floor and a
second exit meeting NFPA 70 f Article 110.26 (C) (2) for rooms with over 1200 amps of
service and equipment over 6 feet wide.
Approved 1/30/11 — based on the one hour rating being provided and no second
door being required as they are providing twice the work area per the exception.
18 El Provide an updated life safety plan for the 3rd floor showing the two required exits per
NFPA 10 1 Chapter 20 separate from the atrium exit that has been separated by a one
hour smoke barrier. WAC 246-330-505
Approved 1115111 — Based on comment response that made the two exit stair
enclosures # 2 and #3 the two required exits for the ASF.
19 21 Change the swing of door # A3 3 1 B to swing in the path of travel to access the second
NFPA exit stair # 3 per NFPA 10 1 Chapter 7.2.1.4.2
Approved 1115111 — Based on comment response and sheet A2.1 that changed the
door swing in the path of egress.
Page 11 of 15 Plan Review Comments for Project # 60237493
Krugqr Orthopaedics
NFPA 101, 2000 Version ASC
Relocation of ASC
0 0
2 0 El Verify or provide the rating of the 3d floor door and wall assembly that door # 300A is
part of to form a smoke barrier to provide the communicating space separation per
NFPA 10 1 Chapter 8.2.5.5
Approved 1115111 — Based on comment response that these doors are in a one hour
I rated fire/smoke barrier wall.
21 Boiler room/mechanical room on roof that has direct access into stair well # 3, which
cannot have direct access to that stairwell per NFPA 10 1 Chapter 7.1.3.2. 1 (d) and the
International building code Section 1022.3
Approved 1/30/11 — based on the door being eliminated from the stair well.
Mechanical:
22 El Modify the following pressure relationships per Table 2.1-2 of the 2006 FGL
(A)Room A324 sub sterile is required to be positive.
Approved 1/30/11 — based on this room being adjusted to a positive pressure
relationship, but less positive than the operating rooms.
23 How is smoke venting provided for anesthetizing locations per NFPA 99 Chapter 5-4.1.2
Approved 1/30/11 — based on comment response of sequencing.
24 El How is humidity addressed for the operating rooms? WAC 246-330-505
Not Approved 1/30/11 — DOH will not require built in humidity, but CRS does need
to know what the policy and procedure is, if the humidity is out of the acceptable
standard ranges and how the facility would know if there were out of range.
25 El How are pressure relationship maintained during off hours and weekends?
WAC 246-320-505
Approved 1/30/11 — based on the AHU's running 24/7 per comment response.
26 El Provide the locations and rating for the pre and final filters for the ambulatory surgery
I facility meeting Table 3. 1 -1 of the 2006 FGL
(Found the Hepa filters in the supply diffusers of the operating rooms, but could not find
the filtering for the rest of the unit.
Approved 1/30/11 — based on sheet MO.02 and notes #12&13 on heat recovery
schedule.
Page 12 of 15 Plan Review Comments for Project # 60237493
Kpgqr Orthopaedics
NFPA 101, 2000 Version ASC
Relocation of ASC
Electrical:
27 El Provide a shared medical gas alarm for the operating rooms located in the same corridor
per NFPA 99 Chapter 4-3.1.2.2 (c) (reference elevations on sheet A7.2)
The recovery area is required to have one of its own.
Approved 1/30/11 — based on sheet E23B that added the area alarm panel.
28 El Provide sprinkler freeze protection in stair wells # 2 & #3 per NFPA 13 5-14.3.3
(reference sheet M2.01)
Approved 1/30/11 — based on a dry sprinkler head being used in the stairwells.
29 El i Provide a physical separation between the normal power distribution and the emergency
distribution transfer switches on the first floor electrical room to prevent essential power
interruption by a failure in the normal distribution per NFPA 70 Article 517.35 (C)
(note this could be a hard wall partition of the room into two areas)
Approved 1/30/11 — based on wing walls being provided to form a separation.
3 0 IHI Recommend that the ice machine in room # A304 be placed on the critical branch of
emergency power as it will supply the ice for patients in hypothermic shock and without
power the ice would not be dispensed from the machine.
Approved 1/30/11 — based on both the freezer and ice machine being provided with
critical emergency power.
31 El Atrium door hold open circuits NL 1 -3 need to drop out on fire alarm as this is a rated fire
barrier. Are these hold open devices on a relay with the fire alarm? WAC246-330-505
(reference sheet E2.3A)
Approved 1/30/11 — based on comment response that the hold opens are controlled
by the fire alarm control panel that drops them upon building alarm.
32 21 Provide two sources of outlet power in operating rooms # A320, # A319 and # A318 per
NFPA 70 article 517.19(A) that requires both normal and emergency power.
(reference sheet E2.3B)
Approved 1/30/11 — based on sheet E23B that added the normal power sources in
addition to the critical power.
3 3 IHI Provide manual pull stations at the entrance to star well # 2 & #3 and at the exit/entrance
to the ASF per 1999 NFPA 72 2-8.2.2 and 2006 FGI 3.7-6.4.1 (reference sheet FAI.3)
Page 13 of 15 Plan Review Comments for Project # 60237493
' ger Orthopaedics
N p
f 101, 2000 Version ASC
Relocation of ASC
Approved 1/30/11 — based on comment response and red lined FA drawing.
3 4 IXI Provide a ground wire that is the same size of the conductor in anesthetizing locations
per NFPA 99 Chapter 3-3.2.1.2 (5)(b)
Approved 1/30/11 — based on sheet E23B typical that shows the ground wire size.
35 El What is the run time on the emergency power generator at full load with the fuel supply
allowance provided? WAC 246-330-505
Approved 1/30/11 — based on comment response that a 12 hour run time will be
provided.
Plumbing:
36 El The faucet for the following hand washing stations must be a gooseneck with either wrist
blades or single lever controls per 2006 FGI 1.6-2.1.3. 1:
>Faucet for sink # P2A convert to gooseneck device
Approved 1/30/11 — based on cut sheet received and comment response that the
faucet type above will be provided.
37 El I Provide a bed pan spray wand on any two of the recovery room patient toilets to facilitate
i disposal of fluid waste in the recover area per 2006 FGI 3.7-2.5.6 (2)
Approved 1/30/11 — based on sheet P05 and comment response that added the bed
pan washers to two patient restrooms.
38 El Provide reduced pressure back flow devices to each sterilizer, the instrument washer and
for the Neptune docking bay hot and cold water connections
per 2006 FGI 3.1-7.1.2.3 (3)(a) (reference sheet P05)
Not Approved 1/30/11 — Provide cut sheets on the Neptune docking station that
verifies that it has no water connections. Typical ones submitted an had water
connections in order to flush out the Neptune mobile unit.
39 El Provide a service isolation valve on the oxygen, Vacuum, nitrous oxide medical gas lines
on the horizontal branch lines as they come off of the vertical riser on the third floor per
NFPA 99 Chapter 4-3.1.2.3 (e) (reference sheet P05)
Recommend that the compressed air branch line also receive a service isolation valve.
Approved 1/30/11 — based on comment response and sheet P05 that added the
isolation valves.
Page 14 of 15 Plan Review Comments for Project # 60237493
K�g�r Orthopaedics
NFPA 101, 2000 Version ASC
Relocation of ASC
40 El The zone valve for the medical gas outlets in the recovery area cannot be located in the
same environment as the outlets per NFPA 99 Chapter 4-3.1.2.3 (d). But there is no other
location to locate it behind a door/wall where it is accessible in the egress route.
I Recommend that the location for the zone valve remain, but that a cross corridor door be
I
I added west of the ante room to form a separate environment.
41 El
Not Approved 1/30/11 — The zone valve needs to be environmentally separated from
the outlets, so that a fire fighter or staff do not have to go into the area of fire
involvement by an oxygen fed fire to shut the gas off.
Provide alternate location.
Note: The third required vacuum outlet is credited to the use of the Neptune units in
each of the operating rooms.
42 El Provide a detail showing the air gap to the drain for the ice machine drain hose of a
minimum I" per International plumbing code Chapter 801.2
Approved 1/30/11 — based on sheet P06 that shows the air gap.
43 1 El Provide a one line drawing off all the medical gas manifold systems showing source
valves, check valves, relief valve, and redundancy switch over device, gauges, master
alarm switch etc meet NFPA 99 Chapter 4-3 and figure 4-3.1.1.6 of the 1999 version.
Not Approved 1/30/11 — Provide the source valve location, check valves from tanks
and relief valve piping routing from them.
i
44 El Specifications on sheet P 10 part 4.14 A speaks to using dental surgical vacuum. This
system is not a level 3 dental system and must meet all the requirements of a level I
medical gas system per NFPA 99 Chapter 4-3.
Approved 1/30/11 — based on sheet P10 update showing a level 1 system.
Compliance with the comments above provided by the Department ofHealth, Construction Review Services, are necessaryfor thisfacility to meet
the requirements of the applicable licensing regulationsfound in the Washington State Administrative Code and associated references. These
comments do not relieve thefacilityfrom the responsibility to meet the requirements of any other applicablefederal, state or local regulations.
In the event of conflicts between otherjurisdictions and these written comments, the most stringent shall apply.
Page 15 of 15 Plan Review Comments for Project # 60237493
r� �1�
OOLWT� "0
PF-T�
Ljj F
TOM
� WAL
17�
I
A
TNIJJO�
I-ST I FTL.-
7.1k I
LJ
k---7
u
Ln
Im7mll.-
127-
-- -- --------- ------- --------- -------
2
FAM OF FOtPADATI
r
<
��ll -PlIFE-F �L'
(��Y SET5ACK PARTIAL FLAN
I E..NMTR��A
6- --k.
N 58-43 '2 W 324 00'
APPR
FAFRI.CEL +;7�
- - "2:,
APPFLNEV AS NOTED
PARCEL 5 BY E;p
Tr-1 FARCEL C
0-:N i
.1 Wl�g 10 tAV*Ab CIVIL fLOWS
Tbr- vw**eFiw. 74��f
EWI� T
1,0N 10T
. it
PARimB Wo FLt(m 4
E PAR =:7
--,f F E S
-ION
PARKING SPACES PROPOSED.. 1
m-wo BARRIER
PAE.M.GSPAU&
BARRIER FFU
01 Zo,,
Sid..
2
Od-
7'
4..
4.. 1
QST W c""J"
A
22 r."- , J,
BENCWMAF�
M LO LOC�TED N A� �-OF-iilAy
P� EL - 35..Sl - ;-Ta
A�E� �E,
E�O� �.l.
SE C�ER OF E��
OF
IS�
L=
5W COWER OF HE B51h
TO- f 4 - AVE� �E Om 14 - 3�
C
EW:LDW, 1.15�
35.2, �J,
I1-15T� TO
E�-
Q Ail
,ANhp, (7�51TEFLAN
NORTH
NEW
FAFRCEL- c
34.042 5QJFT (NEW
ZONJW- CG2
L
r-i
:
1 1
L-J
�OT W --O.�&R
,R
c
< C
c
LL
C
U a
w
C
w LL
Q-
LL
a
a
SITI
F
A-
ol
City of Edmonds Wastewater.Pretreatment Program
2002 "d Ave S., Edmonds, WA 98020
Office: (425) 672-5755 Mobile: (206) 595-3117
Plan Review Comments
Plan Check#: BLD20110815 Date: December 14, 20-11
Project Name/ Address: Edmonds Medical Bldg. Assoc., LLQ, 21401 72nd Ave W., Edmonds
Contact Person/Fax or Email: Wieben, Jim/ jimw(&ddgarchitects.com
Reviewer: Jon Lein Division: Wastewater Treatment Plant / Pretreatment
The subject application has been reviewed but cannot be completed until the following
items have been addressed/completed. Please submit 3 sets of revised drawings to a
Development Services Permit Coordinator, if required, or a written response to the review
comments to the Development Services Permit Coordinator and the Pretreatment
Reviewer.
Jim Wieben and Scott Shanks,
Thank you for responding to the Pretreatment Plan Review Comments dated October 10, 2011.
Your response for hazardous materials disposal and your response for the laundry facility (items
number 3 and #4 in your response) are good. The only clarification I request is a MSDS and/or a
narrative for the Styker Neptune 2 waste management station.
Here is the current Ecology guidance on pharmaceuticals. It has not been revised or finalized
since 2008. The clinic should have their reverse distributorship information available for each
manufacturer or distributor and keep their inventory reports for 5 years just like they do with
their hazwastes.
http://www.ecy.wa.gov/pubs/``0704024.pd
3. Thank you for the information for the temporary drop-off locations. This is the info I have for
Snohomish County for �ersonal med disposal and drop-off.
http://www.snohd.org/Shd MS/Documents/UnwantedMedicinePharmaceuticalsDisposal.pd
4. What I need from you is: In writing that The Edmonds Medical Bldg. Assoc., LLC agrees to follow
the Washington State Department of Ecology Interim Enforcement Policy — Pharmaceutical
Waste in Healthcare and the completed policy when it is updated.
I understand that this may be burdensome and time consuming. However, if we as a people are going to
continue to enjoy safe receiving waters and safe water tables for our drinking water, we must follow
policies that support that goal.
Please call me Monday — Thursday for questions or assistance.
Jon Lein, City of Edmonds Pretreatment Technician
425-672-5755 office
206-595-3117 cell
9 Page I of I
113jorback, Leif
From:
Bjorback, Leif
Sent:
Tuesday, December 13, 2011 2:12 PIVI
To:
'Scott@fwdsinc.com'
Cc:
Yarberry, Leonard
Subject:
Premier Orthopedic
HI Scott,
Thank you for your response to my previous comments. We are down to a couple of minor
issues remaining for me to complete my review. One of the issues involves replacement of a full
sheet. Please find the attached review comments for that issue. The other issue is my previous
item #10, having to do with the outside air provided in the Reception area by the HVAC system.
From what I can tell, your design team was not using the state amended Table 403.3 of the
International Mechanical Code, which would give widely differing values for air volumes. We at
the building department are not sure why the state -amended table uses such large values for
Reception rooms in particular, so we are checking with our sources to see if the numbers in the
table are indeed valid. We would like for this issue to not hold up issuance of the permit, so we
will deal with it less formally and resolve it outside of the review process. I will inform you when
we arrive at something that makes more sense. Feel free to contact me if you have questions.
Regards,
La�f -3j6-t-6ack
Assistant Building Official
City of Edmonds
(425) 771-0220
12/13/2011
0,� E D,,�, City of Edmonds
PLAN REVIEW COMMENTS
BUILDING DIVISION
PS (425) 771-0220
, '.
DATE: December 13, 2011
TO: Scott Shanks
First Western Development Services, Inc.
Ernail: Scott gcfwdsinc.com
FROM: Leif Bjorback, Assistant Building Official
RE: Plan Check: 2011-0816
Project: Premier Orthopedic TI Review #2
Project Address: 21401 72 nd Ave W
During review of the plans for the above noted project, it was found that the following information,
clarifications or changes are needed. Please provide written responses as to where the changes can
be found on the plans, and submit revised plans/documents to Marie Harrison, Senior Permit
Coordinator. Thank you.
1. Previous #12. Provide einergencj, lighting on the 2 "dflool. level. See sheet E3. 2. IBC 1006.3
Your response indicates that changes have been made to the plans, however sheet E3.2 was
not among the sheets resubmitted. This sheet would be the likely place to show the revised
infori-nation. Please resubmit the revised sheet E3.2.
All other corrections have been addressed.
II
TECTURAL
WERKSIN, C
1202D 11M AVE NE
SUrrE 210
KEUCLAND, WA 98034-GM
RE: Plan Check: 2011-0816
Project: Premier Orthopedic TI
Project Address: 21401 72'd Ave. W.
Date: November 16, 201-1
NOV 1 P 26 o
BUILDING DEPP,,P0w+.ko
OITY OF FWAo,,,�rjs
During review of the plans for the above noted project, it was found that the following information,
clarifications -or changes are needed.'. Please provide written responses as to w here the changes can be
found on the plans, and submit revised plans/documents to Marie Harrison', Senior Permit
Coordinator. Thank -you.
1. Please provide acopy of the Washington State DOH Plan, review letter.
Response:'This project is currently under review by the Department of Health.
We will forward their comments to you when we- receive them.
Provide fire stopping specifications and details for through penetrations of firerated
assemblies greater than one hour, or list as a deferre& submittal.
Response: We have included details 24/A6.1 and25/A6.2 for rated penetrations.
The north wall of the elevator hoistway looks to be considered the boundary of the atrium.
.The opening through this wall at the third floor must be protected by a 45 minute fire rated
door. IBC 404.6and Table 715.4
Response: Elevator#1 can be entered from both the north and south sides. We
have added a 45-minute rated door on the north side to continue the I -hour wall
rating around elevator#l. A magnetic hold -open for the door,will be provided.
OI/The window at MRI - Room 375 does not match the plans for the building shell. This window
must be 10 feet'away from the adjacent atrium windows. 18C'l 022.6
Response: The MRI Room window has been moved 10 feet away from the
atrium windows. See DDG/Plan Check: 2011-6�15 permit resubmittal drawings.
V/3� Please indicate on the plans that all fire doors will be self closing or automatic closing.' IBC
715.4.8
Response: The self closing fire doors are 300A, 306A, A30313, A30413, A317A,
A331 B, and A333A. See hardware schedule on sheet A9.1 B for closing devices.
Stairs #2 and 3 will be covered, on DDG/Plan Check: 2011-0815 permit drawings.
ue Please" indicate that all fire doorswill be smoke gasketed. IBC 71.5.4.3. 1'
Response: Fire doors are 300A� 306A, A30313, A30413, A317A, A33113, and
A333A h ' ave smoke gaskets. See hardware schedule on sheet A9.113. Stairs #2
and 3 will be covered on DDG/Plan Check: 2011-0815 permit drawings.
V*< The door to the med gas room must be rated for at least 45 minutes. IBC Table 715.4
Response: This door is a 45 minute door. See DDG/Plan Check:'2011-0815
permit resubmittal drawings.
8�/Indicate that the med gas system will be installed according to UPC chapter 13 and inspected
by a third party as per UPC section 1328�
Response: All medical gas systems will be installed according to UPC Chapter 13
and inspected by a third party as per UPC Section 1328.
Provide trap primers at restrooms with floor drains. UPC 1007.0
Response: All floor drains will have trap primers per UPC 1007.0�
10. It appears the outside air calculated for Waiting Room 306 is insufficient. Using the square
�O footage of 950 provided on sheet MO.01, and IMC Equation 4-1,-my calculations show a
minimum requirement of 1911 cfin for that room. Please show new calculations for the room.
Response: Waiting Room 306 is classified as a Reception Area in 2009 IMC Table
403.3. The ventilation requirements are 5 cfm/person (30 ppl/1000 A2), and 0.06
cfm/ft2. The area of the 'waiting room is 950 fti. The calculation is 30-ppl-x 5,
cfm/person + 0.06 cfm/ft2 x 950 ft2 = 207 cfm. Incorporating an -air distribution
effectiveness of 0.8 (Table 403.3.1.2), the total required ventilation air for Waiting
Room 306 is 207 cfm / 0.8 = 259 cfm- as shown on MO.01.
vl�l - Provide a. sm oke, damper at the air transfer opening through the smoke partition at the level -2
lobby. See sheet M2.02 IBC 711.7
Response: A. smoke damper has been added to the air transfer opening, at Level-2
Lobby.
No - 12. Provide emergency I ' ighting on the 2 nd floor level. See s eet E3.2. BC 1006.3
4;; )fixtures matching first
Response: Emergency fighting now shown as using ix
7, VO4- floor.
Vd
v4J. Clarify the emergency lighting on the 3rd floor'level.'The symbols used on sheet E3.3 don't
seem to match those in the key. IBC 1006.3
Response: The key is generic. The lower left of the key shows emergency fixtures,
upper left is non -emergency. Typically emergency fixtures are shown half shaded
or with an "X" *suffix on the tag. Corridors have fixtures D2X, FlX, R5X, D5X
etc. that all have integral emergency battery ballasts.
Sheets included in Permit Resubmittal:
AO.1, AO.2, AO.3, A2.1, A2.2, , A2.3, A2.4, A2.5, A2.6, AM, A3.2, A4.1
A6.1, A6.2, A6.3, A6.4, AM, A7.29 'A7.3, A7.4, A7.5, A7.6, A7.7, A7.8,
A7..9, A7.11, A7.12, A8.2, A9.1, A9.111
M2.02, M2.03, M2.04
E23A, E3.3, E3.4
FAO.l, FA1.3
TECTURAL
WERKSINC
I IMAVENE
' SUM 210
KMKLANDWA98034-69rI9
RE: , . Plan Check: 2011-0816
Project: Premier Orthopedic TI
Project Address: 2140172 nd Ave. W.
Date' November 16, 2011
RESUN§.
NOV 1 g 2011
IVDS
During review of the plans for, the above noted project, it was found that the following information,
clarifications or changes are needed. Please provide written responses as to where the changes can be
found on the plans, and submit revised plans/documents to Marie Harrison, Senior Permit
Coordinator. Thank you.
1. Please provide,a copy of the Washington State DOH Plan review letter.
Response: This project is currently under review by the Department of Health.,,
We will forward their comments to you when we receive them.
2. Provide fire stopping specifications and details for through penetrations'of fire rated
9
assemblies greater than one hour, or list as a deferred submittal.
. Response: We have included details 24/A6.1 and 25/A6.2 for rated penetrations.
3. The north wall of the elevator hoistway looks to be considered the boundary of the atrium.
The opening through this wall at the third floor must be protected by a 45 minute fire rated
door. IBC 404.6 and Table 715.4
Response: Elevator#I can be entered from both'the north and south sides. We
have added 6 45-minute rated door on the -north side to continue the 1 -hour wall
rating around elevator#1. A magnetic hold -open for the door will be provided.
4. The window at MRI Room 375 does not match the plans for the building shell. This window,
must be lO feet away from the adjacent atriummindows. IBC 1022.6
Response: The IVIRI Room window has been moved 10 feet away from the
atrium.windows. See DDG/Plan Check: .201.1-0815 permit resubmittal drawings.
5. Please indicate on the plans that all fire doors will be self closing or automatic closing. IBC
715.4.8'
Response: The self closing fire doors are 300A, 306A, A30313, A30413, A317A,
A331 B, and A333A. See hardware schedule on sheet A9.1 B for closing devices.
Stairs #2 and 3 will be covered on DDG/Plan Check:. 2011-0815 permit drawings.
6. Please indicate that ail fire doors wil , I bes'moke gasketed. IBC 715.4.3. F
Response: Fire. doors are 300A, 306A, A30313, A30413, A317A, A331 B, and
A333A have smoke gaskets. See hardware schedule on sheet A9.113. Stairs #2
and 3 will be covered on DDG/Plan Check: 201.1-0815 permit. drawings.
7. The door to the med gas room must be rated for at least 45 minutes. IBC Table 715.4
Response: This door is a 45 minute door..See.DDG/Plan Check: 2011-0815
permit resubmittal drawings.
8. Indicate that the med gas system will be installed according to UPC chapter 13 and, inspected
by a third party as per UPC section 1328.
Response: All medical gassystems will be installed according to UPC Chapter 13
and inspected by a. third party as per UPC Section 1328.
9. Provide trap primers at restrooms with floor drains. UPC 1007.0
Response: All floor drains will have trap primers per UPC 1007.0.
10.- It appears the outside air calculated for Waiting Room 306 is insufficient. Using the square
footage of 950 provided on sheet MO.01, and IMC Equation 4-4- ' 'my calculations show a
minimum requirement of 1911 cfm for that room. Please show new calculations for the room.
Response: Waiting Room 306 is classified as a Reception Area in 2009 IMC Table
403.3. The ventilation requirements are 5 cfm/person (30 ppl/1000 ft2), and 0.06
cfm/62. The are ' a of the waiting room is 950 ft2. The calculation is 30 ppl x 5
cfm/person + 0.06 cfm/ft2 x 950 ft2 = 207 cfm. Incorporating an air distribution
effectiveness of 0.8 (fable 403.3.1.2), the total required ventilation air for Waiting
Room 306 is 207 cfm / 0.8 = 259 chn, as shown on MO.01.
11. Provide a smoke damper it the air transfer opening through the smoke partition at the level 2
lobby. See sheet M2.02 IBC 711.7
Response: A smoke damper has been added to the air transfer opening atLevel-2
Lobby.
12. Provide emergency lighting on the 2 d flo' or level ' See sheet E3.2. IBC 1006.3
Response: Emergency lighting now shown as -using N14X fixtures matching first
-floor.
13. Clarify the emergency lighting on the 3rd floor level. The symbols used on sheet E3.3 don't
seem to match those in the key. IBC 1006.3
Response: The key is generic. The lower left of the key shows emergency fixtures,
upper le ft is non-emer . gency. Typically emergency fixtures are shown half shaded'
or with, an "X" suffix on the tag. Corridors have fixtures D2X, FIX, R5X, D5X
etc. that all have integral emergency battery ballasts.
Sheets included in Permit Resubmittal:
AO.1, AO.2, AO.�, A2.1, A2.2, A2.3, A2.4, A2.5, A2.6, AM, A3.2, A4.1.
A6.1, A6.2, A6.3, A6.4, A7.1, A7.2, A7.3, A7.4, A7.5, A7.6, A7.7, A7.8,
A7.9,. A7.11, A7.12, A8.2, A9.1, A9.1B
M2.02, M2.03, M2.04
E2.3A, E3.3, E3.4
FAO.1, FA1.3
TECTURAL
WERKSINC
120n 123th AVE NE
Sul I E 210
KMKL4,NQWANffi"% 9
RE: Plan Check: 2011-0816
Proj ect: Premier Orthopedic TI
Project Address: 21401 72 nd Ave. W.'
Subject: Bld 2011-08 15 Premier T1. 21401 72 nd Ave. W.
Attn: John Westfall, Fire Marshal
Date November 16,2011
18 2011
RUILDINs DEp.4nrWE
01TV OF FDMOiVDSHT
The Fire Department provides the followin'g comments and'corrections in accordance with the 20,09
International Fire Code and Edmonds Community Develop'ment Code Title 19:
1. AO.1 Deferred Submittals:
a. Halon or clean agent suppression systems for DATA STORAGE requires a permit.
Response: Halon will not be provided on this project.
b. Add Fire Protection Footprint (below),
Response: This Deferred Submittal will be submitted later.
c. Add tenant Fire Safety Plan (LSC 20.7.2.2)
- Response: This Deferred Submittal will be submitted later
2. AO. 2
a. General Notes #1: add "NFPA 101 LIFE SAFETY CODE"A edition
Response: This note has,been added, referencing edition 2000, as required by
Washington State Department of Health.
b. Floor plan legend: callout AMBULATORY HEALTHCARE area for tenant. -
Response: This note has been added..
3. AO.2 & A9.1 Exit access must be provided and maintained from all areas. Door schedule
indicates security locks into ASC areas; e.g. door A317A. Corridor and egress doors must be
free to operate in path of egress without special'knowled e or effort. IFC 1014
9 9
Response: Door-A317 is locked from Corridor#328 side, but has no lock on the OR
Corridor#A317 side. Corridor#328 ends at Stair#2, allowing- unrestricted access from
both areas.
Doors-A330A and 306A have panic hardware in the direction of travel.
4. AO.2 Area for OUTPATIENT TREATMENT is.10,684 s.f. If this is.AHC area (in excess of 10,000
s.f. per IBC 422.3):
Response: The Ambulatory Health Care area is 9,050s.f.."Outpatient Treatment"
refers to clinical spaces as well as the ambulatory surgery area.
a.. call out existing 1 hr wall as "smoke barrier" required to provide two smoke compartments
(I BC 422.3)
Response: Since the, AHC area is less than I 0,000s.f. smoke compartments are not
required.
b. specify, and show calculations for REFUGE AREA (IBC 422.4)
Response: Not required.
c. provide independent egress from each smoke compartment without passing through
adjacent tenant spaces (I BC 422.5),
Response: Not required.
5. A21.1 Is one hour fire wall across floor plan intended to be smoke barrier for AHC purposes?
Response: A one -hour fire barrier is required by DOH.
6. A2.5 It appears Elev #1 gives no opening, through 1 hr fire wall to Corridor A303?
Response: Elevator#1 can be entered from both the north and south sid ' es. We have
added a 45-minute rated door on the north side to. continue the 1-hour wall rating
around elevator#l. A magnetic hold -open for the door will be provided..
7. Does tenant intend to install halon or clean agent suppression systems for 2 nd floor DATA
STORAGE space?
Response: Halon will not be provided.
8.. .1s'floor medical gas room is not rated and assumed to be designed,, protected,, and exhausted,,.
as a one -hour interior room (IFC 3006.2.2).
Response: The Medical Gas. Room is one -hour rated and exhausted as shown on
resubmitted drawings from DDG/Plan Check: 2011-0815. See Sheet A-1 11.
9. Information for tenant: Medical gas room storage requires annual �eneWable operational fire'
permit over 504 ft3 quantity. No other action required.
10. Medical gas maximum allowable'qpantity for storage'and piped use of oxidizer gases is 3000 ft3
given sprinkler allowance IFC 2703.1. Callout medical gas system piping capacity and storage
volume to not exceed this limit.
Response: This note -will be added to drawings P03 and pO5.
11. MRI installation may impact 800 MHz emergency responder radio coverage. Acceptable radio
signal strength is required in 95 percent for each,floor @ -95 dBm into,, and -100 dBm out of the
building. Indicate or specify how this Will be accomplished with regard to operating MRI (IFC
510).
Response: The Siemens magnet operates at 64MHz, well outside of the 80OHz
spectrum mentioned below. The RF shield provides ' both 100db attenuation both
from outside EMI sources and from the.magnets gradient coils, internal to the RF
shielded enclosure operating at 64MHz. You will not have any concern re I lated to.
the issue below.
12. A2. 1, A2.3 & A9. 1: Doors 300A, A331 B, A306A appear to impede business flow in closed
position. Call out ' automatic closing fire doors, installed per IBC 715.4.8.2.,
Response: Door300A is held open with magnetic hold-openg.
DoorA331 B is used. by staff or patients accompanied by staff and is intended to be
closed.
Door#306A connects the Clinic Waiting and the ASC Reception and is intended to.
be closed.
0
OUTDOOR AIR CALCULATOR
Vbz= RpPz+ RaAz
2009 Imc PrZ.,&-t, P14-111
Room/ Area/ RTU #
oT
4&�Kf"t +o Lveu�41:m, 4.ilove,
E
City of Edmonds,
PLAN REVIEW COMMENTS
BUILDING DIVISION
(425) 771-0220
S1.
DATE: November 7, 2011
TO: Scott Shanks
First Western Development Services, Inc.
Email: Scott(cDfwdsinc.com
FROM: Leif Bjorback, Assistant Building Official
RE: Plan Check: 2011-0816
Project: Premier Orthopedic TI
Project Address: 21401 72'd Ave W
During review of the plans for the above noted project, it was found that the following information,
clarifications or changes are needed. Please provide written responses as to where the changes can
be found on the plans, and submit revised plans/documents to Marie Harrison, Senior Permit
Coordinator. Thank you.
I . Please provide a copy of the Washington State DOH plan review letter.
2. Provide fire stopping specifications and details for through penetrations of fire rated
assemblies greater than one hour, or list as a deferred submittal.
3. The north wall of the elevator hoistway looks to be considered the boundary of the atrium.
The opening through this wall at the third floor must be protected by a 45 minute fire rated
door. 113C 404.6 and Table 715.4
4. The window at MRI Room 375 does not match the plans for the building shell. This window
must be 10 feet away from the adjacent atrium windows. IBC 1022.6
5. Please indicate on the plans that all fire doors will be self closing or automatic closing. IBC
715.4.8
6. Please indicate that all fire doors will be smoke gasketed. IBC 715.4.3.1
7. The door to the med gas room must be rated for at least 45 minutes. IBC Table 715.4
8. Indicate that the med gas system will be installed according to UPC chapter 13 and inspected
by a third party as per UPC section 1328.
9. Provide trap primers at restrooms with floor drains. UPC 1007.0
10. It appears the Outside air calculated for Waiting Room 306 is insufficient. Using the square
footage of 950 provided on sheet MO.01, and IMC Equation 4-1, my calculations show a
minimum requirement of 1911 cfm for that room. Please show new calculations for the
room.
11. Provide a smoke damper at the air transfer opening through the smoke partition at the level 2
lobby. See sheet M2.02. IBC 711.7
12. Provide emergency lighting on the 2 nd floor level. See sheet E3.2. IBC 1006.3
13. Clarify the emergency lighting on the 3 rd floor level. The symbols used on sheet E3.3 don't
seem to match those in the key. JBC 1006.3
Page I of I
Bjorback, Leif
From: 13jorback, Leif
Sent: Monday, November 07, 2011 3:18 PM
To: 'Scott@fwdsinc.com'
Subject: Premier Orthopedic TI
Hi Scott, please see the attached building division plan review comments for your project. Feel
free to call with any questions.
Regards,
Le,�f Bjcn-ba,,--�
Assistant Building Official
City of Edmonds
(425) 771-0220
11/7/2011
MEMORANDUM
Date: November 13, 2011
To: Scott Shanks scott(a)fwdsinc.com
From: John Westfall, Fire Marshal 'westfallC@firedistrictl org
Subject: Bid 2011-0815 Premier TI 21401 72 nd Ave W
The Fire Department provides the following comments and corrections in accordance with the 2009
International Fire Code and Edmonds Community Development Code Title 19:
1. AO.1 Deferred Submittals:
a. Halon or clean agent suppression systems for DATA STORAGE requires a permit.
b. Add Fire Protection Footprint (below)
c. Add tenant Fire Safety Plan (LSC 20.7.2.2)
2. AO. 2
a. General Notes #1: add "NFPA 101 LIFE SAFETY CODE" & edition
b. Floor plan legend: callout AMBULATORY HEALTHCARE area for tenant.
3. AO.2 & A9.1 Exit access must be provided and maintained from all areas. Door schedule
indicates security locks into ASC areas; e.g. door Al 17A. Corridor and egress doors must be
free to operate in path of egress without special knowledge or effort. IFC 1014
4. AO.2 Area for OUTPATIENT TREATMENT is 10,684 s.f. If this is AHC area (in excess of 10,000
s.f. per IBC 422.3):
a. call out existing 1 hr wall as "smoke barrier" required to provide two smoke compartments
(I BC 422.3)
b. specify, and show calculations for REFUGE AREA (IBC 422.4), and
c. provide independent egress from each smoke compartment without passing through
adjacent tenant spaces (IBC 422.5)
5. A2.1 Is one hour fire wall across floor plan intended to be smoke barrier for AHC purposes?
6. A2.5 It appears Elev #1 gives no opening through 1 hr fire wall to Corridor A303?
7. Does tenant intend to install halon or clean agent suppression systems for 2 nd floor DATA
STORAGE space?
8. 1st floor medical gas room is not rated and assumed to be designed, protected, and exhausted
as a one -hour interior room (IFC 3006.2.2).
City of Edmonds �b Office of Fire Marshal
0
9. Information for tenant: Medical gas room storage requires annual renewable operational fire
permit over 504 ft3 quantity. No other action required.
10. Medical gas maximum allowable quantity for storage and piped use of oxidizer gases is 3000 ft3
given sprinkler allowance IFC 2703.1. Callout medical gas system piping capacity and storage
volume to not exceed this limit.
11. MRI installation may impact 800 MHz emergency responder radio coverage. Acceptable radio
signal strength is required in 95 percent for each floor @ -95 dBm into, and -100 dBm out of the
building. Indicate or specify how this will be accomplished with regard to operating MRI (IFC
510).
12. A2. 1, A2.3 & A9. 1: Doors 300A, A331 B, A306A appear to impede business flow in closed
position. Call out automatic closing fire doors, installed per IBC 715.4.8.2.
Attachment: Fire Protection Footprint
Edmonds Plaza
1500 Main Street
Occupancies: R1 . A3, 8, M
Type of Construction: VI -hour
2 stories with basement
Total Building Area: 32,456 of
1997 UBC, UMC, UFC, UPC, WSEC, VIAQ, State Barrier Free Code
Fire Apparatus Access: Paved West. South and East sides
Active Fire Pro faction
Fire sprinkler system (specify UBC Std. 9-1 or 9-3) T V
Fire sprinkler control panel location
Fire Deparlment connections
Fire alarm system W/ smoke detection and manual pulls Retail Retaill
Fire alarm control panel location
Illuminated exit signs IAI NJ
Emergency fighting wl battery back-up REM
HVAC automatic shutdown
Kitchen Type I hood and suppression system
Fire Extinguishers R-mumn
Passive Fire Protection
Smoke control system
Escape windows from sleeping rooms
1 -hour rated corridor/exit passageway
Attic draft stops
Elevator smoke door
Structural Protection
Exterior load -bearing walls
Interior load -bearing walls
Exterior non -bearing walls
Structural frame
Permanent partitions
Shaft enclosures
Floor -calling
Roof -coiling
Exterior openings
Stair enclosure
Roof material class
= 1-hour
= 1-hour
= 1 -hour
= 1-hour
= 1-hour
= 1-hour
= 1-hour
= 11-hour
= NIA due to location on property
= 1 -hour
= Type B
— — 00
FIRST FLOOR
N
rre IN
�Xl
LEGEND
I hOur Coiiidof Irith self.
closing. ruled dooni.,atod
g azing. file/smok. damp— it
I'
ducl penetrations
— — — — — -
I hour at.d ..If assembly
2 hour Area Separatim Wall
Wth rated door. ard glazing
A
Required exit tO the exterior
of the building
Area Of EvRCUatiOn AssIs4ince
Fire DOPOrtment C—ectlon
20 min. ratod, self-oosing dwr
G)
60 min. rated. self -closing doof
Q
90 min. raled, self -closing di-
0,
Sample Fire
Protection
Footprint
Date Prepared
Last Updated
2
0
is
- .1. t. t:81 _� 1-61 LLC.
ABOSSEIN NOIN RINC,
�V x
L
..Mtchnnieal� HlectncJ Fire Protcction,- 04v- LEHU_�C8M
November 18'h, 2011
Ms. Jeanie McConnell
City of Edmonds
Engineering Division
121 5h Ave. N.
Edmonds, WA. 98020
Ref.: Premier Orthopedics
Dear Ms. McConnell,
Please find below our response to your Plan Review Comments dated 11/16/2011.
aim
P02:
1. Type I catch basin requirement - Catch Basin are not required to be used as individual garage
drains by code. We are providing floor drains that are selected for the type of use and then
piped through a sand/oil interceptor. This design is per the 2009 UPC and does not require
revision.
2. Backwater valve in lieu of 2" vent — A 2" vent is required by code. A backwater valve cannot.
be used instead of a vent and is not required by code. No change is required here.
1. Storm retention vault note — Note has been revised as requested.
2. Detention vault manholes locations — The location and requirements of the storm drain
detention vault manholes is be provided by the civil engineer.
3. Line typos for garage drainage and sanitary sewer pipes — The garage drain line types have
been revised to read GD (Garage Drainage).
4. Location of backwater valve — A backwater valve is not required by code.
Oil[Water separator drainage — The oil/water separator is not the only drain in the garage. It
is one of the drains in the garage. The other drains are a floor drain type -of drain and then
piped through the oil/water separator. No revisions are required here.
Main Office: 2100 112th Ave NE, Suite 201, B.Hrue, TA 98004 Phone: 426-462-9441 / Fa= 426-462-9461
260 Petaluma Blvd N., Suite A, Petaluma, CA, 94962
829 2nd stred, Suite 2, mulilteo, vA 98275
728 Broadway, Suite 2B, Tacoma, VA 98402
www.aboosain.com
JA21107MConnspondenceTermit Response Fng Div.DOC Page I of 2
P03:
1. D5 drains — The D5 drains shown here serve level I parking slab. These drawings are
configured to industry'standards. No revision required.
2. Oil/Water interceptor not shown on correct plan — The plans are set up per industry standard.
No revisions required.
PO4:
1. D5 drain locations — The plans are set up per industry standard. No revisions required.
I hope this information resolves your concerns. Please contact me at 425462-9441 if there are any
,..d,ditiona[quqstlpns.,,
Sincerel
yl
Dennis Grovenburg
Mechanical Department
DG/kh
Page 2 of 2
Message
& Page I of I
McConnell, Jeanie
From: McConnell, Jeanie
Sent: Wednesday, November 16,20112:48 PM
To: 'Scott Shanks'
Cc: 'jimw@ddgarchitects.com'; Harrison, Marie
Subject: Premier Ortho, bld20110816 (TI) - Engineering Comments
Scott,
Please find attached comments from the Engineering Division in review of the TI permit for Premier
Orthopedic.
Regards,
Jeanie
3EANIE McCONNELL I Engineering Program Manager I mcconnellOcLedmonds.wa.us
Public Works Department I Engineering Division 1 121 5th Ave N I Edmonds, WA 98020
City of Edmonds I www.edmondswa.go I Tel: 425.771.0220 1 Fax: 425.771.0221
11/16/2011
of E DV 0 CITY OF EDMONDS
PLAN REVIEW COMMENTS
(425) 771-0220
ENGINEERING DIVISION
City Website: www.edmondswa.go
DATE: November 16, 2011
TO: Scott Shanks
scott@fwdsinc.com
FROM: Jeanie McConnell, Engineering Program Manager
RE: Application #: bld20110816
Project: Premier Orthopedic Group — Tenant Improvement
Project Address: 2140172 "d Ave W
During review of the above noted application, it was found that the following information,
corrections, or clarifications are needed. Please submit three (3) sets of revised plans/documents
with a written response to each of the items below to Marie Harrison.
City of Edmonds handouts, standard details and development code can be referenced on the City
website.
NOTE: Shell & Core, Civils were reviewed under separate permit - 01d20110815.
AO.3 — REFERENCE SITE PLAN
1. Please remove notes regarding frontage improvements (painting curb, dimensions of parking
and service entry).
2. Please add a note that references the civil construction plans for engineering requirements.
P01 — LEGEND, SCHEDULES & GENERAL NOTES
I . D5 in the plumbing fixture connection schedule indicates a garage drain. Typically basins
installed within parking garages are Type I basins. Please confirm the size of basin to be
installed.
2. Detail 1. 1 shows a 2" vent on the 4" waste outlet pipe. In lieu of the vent installation of a
backwater valve seems appropriate. This would prevent any sewer backup from entering the
parking garage through this structure.
P02 — FOUNDATION PLAN — WASTE AND VENT
1. The note at the storm detention vault states "storm water detention vault by other. Field verify
exact location". Please revise this note to state "see civil construction drawings for detention
vault details".
bld20llO8l6-Premier—Ortho-TI-El.doc Page I of 2
2. Please show the location of the access manholes in the detention vault so it is clear these surface
structures are part of the storm drainage system.
3. Revise line types to differentiate between the sanitary waste lines and the other lines that will
connect to the oil/water separator and then the sewer system.
4. Please show location of backwater valve on the outlet side of the oil/water separator should you
choose to install one.
5. The oil/water separator is the only drainage basin that has been shown on this plan sheet. There
are other locations throughout the garage where it appears as though catch basins should
be/could be installed ... please clarify and add basins where necessary.
P03 — LEVEL 1 FLOOR PLAN — WASTE AND VENT
1. Please clarify that the D5 drains shown on this plan sheet will be accessed at the 2 nd floor
parking slab.
2. The oil/water separator is shown on this plan sheet, but it is not at the level of the waste lines
that are shown. Please grey out/dash line type.
PO4 — LEVEL 2 FLOOR PLAN — WASTE AND VENT
D5 drains are shown, but are not at the same level as the waste lines that are shown. Please grey
out/dash line type.
Please contact me at 425-771-0220 or by e-mail at mcconnell(i�cixdmonds.wa.us if you have
specific questions regarding these plan corrections.
M20110816-Premier—Ortho-TI-E I.doc Page 2 of 2
ABOSSEIN ENGINEERING, ac
Mechanical - Electricali- Fire Protection -Civil -LEED—CEM,
November 18", 2011 NOV 2 12011
WILDING DEPARTMENT
CXTY OF EDMONDS
Mr. Leif Bjorback
City of Edmonds
Building Division
121 5th Ave. N.
Edmonds, WA. 98020
Ref.: Premier Orthopedics, Plan Check #: 2011-0816
Dear Mr. Biorback,
I have reviewed your comments #: 8 & 9 on the above referenced project and have the following
response:
Comment #: 8 Medical gas system installation requirements — A note has been added to sheets P03 and
P05 requiring medical gas system to be installed per Chapter 13 of the UPC.
Comment #: 9 There is a note on the Plumbing Fixture Schedule that requires trap primers for floor
drains. See note #: 2.
I hope this information resolves your concerns. Please contact me at 425-462-9441 if there are any
additional questions.
Sincerely,,
Dennis Grovenburg
Mechanical Department
DG/kh
Main Office: 21oo n2th Ave NE, Suite 201, Bellevue, WA 98004 Phone: 425462-9441 / Pax: 425-462-9451
260 Petaluma Blvd N., SuiteA, Petaluma, CA 94962
829 2.a Street, Suite 2, M.66o, TA 98275
728 Broadway, Suite 2B, Tacoma, WA 98402
www.abonsain.com
JA21107MCon-espondenceTermit Response Bldg. Div.130C Page I of 1
Mr. Leif Bjorback
City of Edmonds
Building Division
121 5th Ave. N.
Edmonds, WA. 98020
Ref.: . Premier Orthopedics, Plan Check #: 2011-0816
Dear Mr. Biorback,
I have reviewed your comments #: 8 & 9 on the above referenced project and have the following
response:
Comment #: 8 Medical gas system installation requirements — A note has been added to sheets P03 and
P05 requiring medical gas system to be installed per Chapter 13 of the UPC.
Comment #: 9 There is a note on the Plumbing Fixture Schedule that requires trap primers for floor
drains. See note #: 2.
I hope this information resolves your concerns. Please contact me at 425-462-9441 if there are any
additional question's.
DG/kh
Main Of6e: 2ioo n2th Ave NE, Suite 201, Bellevue, WA 98004 Phone: 425-462-9441 / Pax: 425-462-9451
260 Petaluma Blvd N., Suite A, Petaluma, Ck 94962
829 2nd Street, Suite 2, Multilteor WA 98275
728 Broadway, Suite 2B, Tacoma, WA 98402
www.atoosein.com
J:\211075\Coffespondence\Permit Response Bldg. Div.130C
Page I of 1
SSEIN EN' INE5RIWI
jjil�.A, 0 LLC
Ivi
November 18'hl, 2011
Ms. Jeanie McConnell
City of Edmonds
Engineering Division
1215" Ave. N.
Edmonds, WA. 98020
Ref.: Premier Orthopedics
Dear Ms. McConnell,
Please find below our response to your Plan Review Comments dated 11/ 16/2011.
POI
P02:
1. Type I catch basin requirement - Catch Basin are not required to be used as individual garage
drains by code. We are providing floor drains that,are selected for the type of use and then
piped. through a sand/oil interceptor. This design is per the 2009 UPC and does not require
revision. ,
2. Backwater valve in lieu of 2" vent — A 2" vent is required by code. A backwater valve cannot
be used instead of a vent and is not required by code. No change is required here.
1. Storm retention vault note — Note has been revised as requested.
2. Detention vault manholes locations — The location and requirements of the storm drain
detention vault manholes is be provided by the civil engineer,
3. Line typos for garage drainage and sanitary sewer pipes — The garage drain line types have
been revised to read GD (Garage Drainage).
4. Location of backwater valve — A backwater valve is not required by code.
5. Oil/Water separator drainage — The oil/water separator is'not the only drain in the garage. It
is one of the drains in the garage. The other drains are a floor drain type of drain and then
piped through the oil/water-separator. No revisions are required here.
Main Offike: 21oo n2th A,,e NE, Suit. 201, Bell.., TA 98004 Phone: 426-462-9441 / F= 426-462-9461
260 Petaluma Blva N., Suite A, Petaluma, Qk 94962
829 2na Street, Suite 2, Mulilteo,WA 98276
728 Broadway, Suite 2B, Tacoma, VA 98402
www.aboosein.com
3A211075\CoMI'pondence\Pcrmit Response Fng Div.DOC Page I of 2
P03:
1. D5 drains — The D5 drains shown here serve level I parking slab. These drawings are
configured to industry standards. No revision required.
2. Oil/Water interceptor not shown on correct plan — The plans are set up per industry standard.
No rev.isions required.
PO4:
1. D5 drain, locations —The plans are setup per industry standard. No revisions requited.
I hope this information resolves your concerns. Please contact me at 425-4.62-9441 if there are any
40oitional,que ons�,
" Sti- .
Dennis Grovenburg
Mechanical Department
DG/kh
Page 2 of 2
MEMORANDUM
Date: November 27, 2011
To: Scott Shanks scott4,ftdsinc.com
From: John Westfall, Fire Marshal
Subject: Bid 2011-0815 Premier T1 21401 72 "d Ave W SECOND
The Fire Department provides the following comments and corrections in accordance with the 2009
International Fire Code and Edmonds Community Development Code Title 19:
Previous corrections and comments accepted from Fire memo dtd 11/13/11
1. Emergency generator correction moved from building shell permit: Provide specifications on
emergency generator, including fuel type & capacity.
City of Edmonds Sb Office of Fire Marshal
0 0
Westfall, John
From: Westfall, John
Sent: Sunday, November 27, 2011 1:07 PM
To: 'scott@fwdsinc.com'
Cc: Harrison, Marie; Mike Smith - Fire District 1
Subject: BLD2011-0816 Premier TI 21401 72 W SECOND.doc
Scott:
Fire Dept correction moved from shell permit.
Thank you,
--ts,
BLD2011-0816
Premier TI 21401 ...
John I Westfall
Fire Marshal
Fire Prevention Services
425-771-0213 Desk
425-775-7721 Fax
425-231-3644 Mobile
ma
Westfall, John
From: Westfall, John
Sent: Sunday, November 13, 2011 12:26 PM
To: 'scott@fwdsinc.com'
Cc: Bjorback, Leif; Mike Smith - Fire District 1
Subject: BLD2011-0816 Premier TI 21401 72 W.doc
Scott:
Attached are comments for Premier TI in Edmonds.
BLD2011-0816
Premier TI 21,401 ...
John I Westfall
Fire Marshal
Fire Prevention Services
425-771-0213 Desk
425-775-7721 Fax
425-231-3644 Mobile
FJ-
DE TIT" T
0
Machuga,Jen
From: Machuga,Jen
Sent: Thursday, November 10, 20112:37 PM
To: 'jimw@ddgarchitects.com'
Cc: 'Scott Shanks'
Subject: Plan Review Comments for Premier Orthopedic Group (BLD20110815 and BLD20110816)
Hi Jim,'
The Planning Division's comments on the building permit applications for the Premier Orthopedic Group building and
tenant improvement (BLD20110815 and BLD20110816) are attached. I am also attaching the design review comments
referenced in my letter. Please feel free to contact me if you have any questions.
Sincerely,
Jen
rovwlio-
11-0815 and ADB-11-63 Request
1-0816 Review 1.p.. for Addition...
Jennifer Machuga, Associate Planner
City of Edmonds, Planning Division
121 - 5th Avenue North
Edmonds, WA 98020
(425) 771-0220 ext. 1224
Machuga@ci.edmonds.wa.us
0 0
CITY OF EDMONDS - 1215'h AVENUE NORTH - EDMONDS, WA 98020
PHONE: 425.771.0220 - FAx: 425.771.0221 - WEB: www.ci.edmonds.wa.us
DEVELOPMENT SERVICES DEPARTMENT: PLANNING - ENGINEERING - BUILDING
November 10, 2011
Mr. Jim Wieben
DDG Architects
Email: j imw@ddgarchitects.com
RE: PLAN REVIEW COMMENTS FOR PLAN CHECKS BLD20110815 & BLD20110816
PREMIER ORTHOPEDIC GROUP, LOCATED AT 21401 — 72ND AVE. W
Dear Mr. Wieben:
I have reviewed the above building permit applications for the Planning Division, and it was found
that the following information, corrections, or clarifications will need to be addressed before review
can continue:
1. Height Calculations: Please respond to the following items regarding the height calculations:
a. Change the style of the height rectangle as shown on the site plan (A-101) in order to avoid
confusion with the other line styles utilized for the building outlines. A dashed or dotted
line utilized for the height rectangle would be easier to distinguish from the other line styles
utilized for the building.
b. Correct the location of the height rectangle to reflect the definition of height contained
within ECDC 21.40.030 which states, "average level shall be deten-nined by averaging
elevations of the downward projections of the four comers of the smallest rectangle which
will enclose all of the building, excluding a maximum of 30 inches of eaves. If a comer
falls off the site, its elevation shall be the average elevation of the two points projected
downward where the two sides of the rectangle cross the property line." As such, the
height rectangle needs to be revised to show where the southeastern comer of the height
rectangle falls off site. Additionally, the elevation of the southeastern comer of the height
rectangle must be based on the average of the two points where the rectangle crosses the
property lines.
c. Update the average grade and maximum allowed height based on the revised elevation of
the southeastern comer of the height rectangle as discussed above. When updating the
height calculations, note that the elevations of the average grade and maximum allowed
height cannot be rounded up.
d. The elevation of the proposed building height was provided on the plans, but please also
include the elevation of the highest point of the mechanical equipment.
2. Setbacks: The CG2 zone requires a minimum four -foot street setback. Although the plans
indicate that the face of the main entrance to the building will be a minimum of four feet from
the western property line, several of the plan sheets (including A-101, A-1 16, A-130, and
A-301) indicate that the gold decorative strip on the wall of windows as well as the building
overhang, particularly over the main entrance, project into the minimum required four -foot
setback area. Unfortunately, there are no exceptions in the General Commercial site
development standards for any portions of the structure to project into the four -foot street
setback. Additionally, the PUD vault located at the northwestern comer of the site cannot be
located within the street setback unless it is less than three feet in height. Please revise the .
plans to indicate that all portions of the structure as well as the PUD vault will comply with the
minimum required four -foot street setback.
0
3. Mechanical Eguipment: Documentation has been provided as part of the associated design
review application showing that the mechanical equipment is not anticipated to be visible from
street view. Please note that the permit will be conditioned such that if the mechanical
equipment is visible from street view, it will need to be painted to match the building or
otherwise screened in a manner acceptable to the Planning Division.
4. Desin Review: Design review for the subject proposal is being conducted concurrently with
the building permit applications under File No. PLN20110063. Comments regarding the
design review application were sent to Scott Shanks and Dale Pinney on November 9, 2011
(see enclosed). Please note that following response to these items and following design review
approval, the building permit application plans, including the landscaping plan, may need to be
revised to reflect the plans approved through the design review process as well as any
conditions of design review approval.
5. Landscaping Estimate: Several comments related to the landscape plan were included in the
enclosed letter regarding the design review application. Once the requested changes have been
made to the landscape plan, please provide a cost estimate for all labor and materials for
installation of the landscaping. This estimate will be utilized for calculation of the required
landscape maintenance bond. The maintenance bond itself, however, does not need to be
submitted until the landscaping has been installed. The maintenance bond will be requested at
the time of the Planning Division's inspection of the project.
All submittals should be made to a Development Services Permit Coordinator, Monday through
Friday, between 8:00 am and 4:30 pm. If you have any questions, feel free to contact me at (425)
771-0220, ext. 1224.
Sincerely,
Development Services Department - Planning Division
I;gap
��Fp' 1,
Jen Machuga
Associate Planner
Enclosure: Letter Regarding File No. PLN20110063 dated November 9, 2011
Cc: Scott Shanks via email to scott@fwdsinc.com
1")C. J'BoQ3
CITY OF EDMONDS
121 5th AVENUE NbRTH - EDMONDS, WA 98020 - (425) 771-0220 - FAX (425) 771-0221
Website: Wwwdedmondsmai.us
DEVELOPMENT SERVICES DEPARTMENT
November9,2011
Mr. Scott Shanks and Mr. Dale Pinney
First Western Development Services
8129 Lake Ballinger Way, Suite 104
Edmonds, WA 98026
Subject: Request for Additional Information for Your Land Use Application
For Design Review of the Premier Orthopedic Building at 2140172 nd Ave. W
File No. PLN20110063
MIKE COOPER
MAYOR
Dear Mr. Shanks and Mr. Pinney:
S taff has reviewed your resubmittal materials for your design review application for the proposed Premier
Orthopedic building located at 2140172 nd Avenue West. Thank you for revising your plans to address most of
our concerns related to the design of the building. There are just a few items remaining that need to be
addressed before design review can be completed. Please respond to the following items at your earliest
convenience so that staff s review of your application can continue:
I . Windows: It was noted that the windows near the center of the eastern fagade were made shorter by
placing a narrow concrete panel at the base of these windows. It appears that these windows. are
located within the "prov. bullpen" room. Is there a reason why these windows are smaller causing an
interruption in the solid row of windows along the third floor? If not, it would look more uniform for
all of these windows along the third floor to be of the same height.
2. PUD Vault: An electrical vault is shown at the northwestern comer of the site. Please note that the
vault may not be located within the minimum required -four foot street setback from the western
propertyline if the vault exceeds three feet in height. Is this the only possible location for the vault?
Would it be possible to put the.vault underground or to move it to a less visible location? If the '
northwest comer is the only possible location for the vault, could it be moved a few feet further to the
east so that it is as far back from the western property line dspossible in order to provide enough
space for screening vegetation?
3. Setbacks: The site plan (sheet A-1 01) indicates that the main entrance to the building will be 4.04 feet
from the western property line, but this plan shows the gold decorative strip on the northern side of the
p
wall of windows as well as the building overhang at the main entrance projecting into the minimum
required 4-foot street setback- Unfortunately, there are no exceptions'in the CG site development
standards for any portions of the structure to project ' into the 4-foot street setback. This can be added
as a condition of design review approval; however, please note that the plans for the building permit
application will need to be revised so that all portions of the structure will comply with the 4-foot.
street setback. Additionally, the PUD vault discussed above will also need to be shown to comply
with the street setback requirements.
4. Parapet: It was noted that the parapet on the northern side of the building is taller t ' han the parapets on
the other sides of the building, creating a step in the parapets at the northeastern and northwestern
comers of the building. Is there a particular reason that the tops of the parapets do not line up in these
locations? Would it be possible to raise or lower the heights of the parapets so that they line up at all
comers of the building?
Incorporated August 11, 1890
Sister City - Hekinan, Japan
0 0
6.
7.
Parking Garage Screenin: During our meeting on September 206, it was indicated that you would
look into the feasibility of providing a low screening wall on the first floor of the parking garage.
Screening of parking is necessary pursuant to ECDC 16.60.030.A.2.b. It is understood that there are
minimum opening requirements for ventilation of the parking garage since this is proposed to be an
open parking garage. However, based on the Building Division's calculations, it appears that there is
more than enough opening area for the first floor of the garage. As such, a screen similar in style to
the guardrail on the second floor of the parking garage could be utilized to assist with screening the
cars on the first floor of the parking garage. Although the landscaping will assist in partially screening
cars on the first floor of the garage, a more permanent method for screening the cars is desired. This
is partially due to the fact that typically grasses must be cut back significantly or even cut to the
ground during the winter, and even if they are not cut back, they will be more sparse in the winter.
This would greatly reduce any screening provided by the landscaping and causes the need for more
permanent screening of the cars. Of particular concern are the western and southern building fagades,
which can be seen from 72'd Ave. W. Please revise the plans to include a low screening wall (a
minimum of 3.5 feet tall) on at least the western and southern fagades of the first floor of the parking
garage similar in style to that on the second floor of the garage. In addition to helping bring the
proposal into compliance with ECDC 16.60.030.A.2.b, this will also bring the proposal into
compliance with the landscaping requirements of ECDC 20.13.030.C.3.c by utilizing a combination of
opaque "fences" and shrubs to produce a visual barrier of at least 3.5 feet in height to screen the
parking area.
Lightina: Staff s letter sent on September 19, 2011 requested additional information related to
proposed lighting. It does not appear, however, that this item was responded to with your resubmittal.
Please indicate the style and materials of any proposed exterior lighting fixtures.
Sianagge: The elevation views that were part of your resubmittal indicate future signage. Please note
t . hat signage will be reviewed for code compliance at the time of submittal of a sign permit application.
However, I wanted to refer you to our sip code requirements of ECDC 20.60 and to bring a few
items related to the signage indicated on the design review plans to your attention at this time. ECDC
20.60.025.A limits the maximum number of permanent signs to three per site, or three per physically
enclosed business space on commercial sites with multiple business tenants. This code section also
limits the total maximum permanent sign area for the site to one square foot per lineal foot of the .
building frontage along 72nd Ave.V. Additionally, it should be noted that a freestanding sign located
within the four -foot street setback cannot exceed three feet in height. These comments regarding
signage do not ne ' ed to be responded to at this time, but please note that they will need to be addressed
as well as any additional applicable sign code requirements of ECDC 20.60 upon submittal of a sign
permit application.
Landscgpin : Note that the following landscaping comments are based on the landscape plan
submitted on October 12, 2011. Although landscaping is shown on the elevation views, it does not
entirely match what is indicated on the landscape plan. Landscaping is not required to be shown on
the elevation views, so any changes being made to the landscape plan do not need to be reflected on
the elevation views. Please respond to the following regarding the landscape plan:
a. Within the plant schedule, update the minimum sizes at installation as follows in order to reflect
the requirements of ECDC 20.13.01 5.B: Japanese maple should be minimum of 8 feet in height;
arborvitae should be a minimum of 6 feet in height; photinia and vibumum should both be a
minimum of 18 inches in height.
b. The cross -hatching near the southeastern comer of the site surrounding the existing trees to be
retained is not indicated in the plant schedule. Please indicate what this cross -hatching represents.
c. If it is not possible to put the PUD vault underground or to move it to a less prominent location
(see related comment above), please revise the landscape plan to indicate sufficient screening of
the vault from view from the north, west, and south. It is suggested that the vault be moved to
further the east (it must be a minimum of four feet from the western property line if over three feet
in height) in order to provide sufficient space for screening landscaping. Instead of screening it
Page 2 of 3
0 0
with grasses, it is suggested that the vault be screened with taller evergreen shrubs that will grow
to be higher than the height of the vault itself.
d. The landscape plan indicates six fastigiate white pine trees along the western side of the site.
Although this species starts out as a columnar tree, as it ages, it can mature at up to 60 feet tall
and 15 to 20 feet wide. This is of concern on the western side of the site where there is only
approximately 10 feet between the building and the western property line, which could cause the
need for major pruning or even removal of these trees in the future. It is suggested that you
consider a smaller evergreen that is more suitably sized for the western side of the site, such as a
columnar Norway spruce (Picea abies cupressina), which grows to approximately 3 )0 to 40 feet in
height and 8 to 10 feet in width.
e. Landscaping along all four sides of the site is required to comply with the Type III landscaping
requirements. Please describe how each side of the site is in compliance with the Type In
requirements of ECDC 20.13.03O.C.
f. During our meeting on September 20'h, it was suggested that a combination of a taller species,
such as arborvitae, be utilized in combination with a smaller shrub along the northern side of the
property in order to he ' Ip break up the northern fagade and to achieve Type IH landscaping.
Would it be possible to establish arborvitae or another taller species at a minimum of 30 foot
intervals along the northern side of the site adjacent to the walkway?
g. It is suggested that evergreen shrubs, such as the compact strawberry tree or Fraser's photinia that
are utilized on the eastern side of the site, be established amongst the grasses on the western and
southern sides of the site in order to add some height to the landscaping adjacent to.the open bays
of the parking garage and to provide denser, year-round vegetation in these areas of the site.
li. Please provide written acknowledgement from the property owner that they understand that if the
existing trees that are proposed to be retained near the southeastern comer. of the site and/or the
existing trees that are to be transplanted near the southern side of the site do not survive during the
construction project, a landscape plan revision may be ]required and new trees may be necessary
near these locations.
9. Engineering Di Vision Review: It should be noted that the Engineering Division has approved the
subject design review application and issued the attached memo on November 8, 2011. Any
remaining comments from the Engineering Division, including comments on the proposed civil plans,
will be provided during their review of the associated building pen -nit applications.
Please note that your application will be placed on hold until a response is received regarding the above items.
Pursuant to ECDC Section 20.02.003.1), you must submit the above infon-nation within 90 days. Thus, your
application will expire if the requested information is not received by February 7, 2012.
If you have any questions, please do nothesitate to contact me at (425) 771-0220, extension 1224.
Sincerely;
Development Services Department - Planning Div ision
Jen Machuga
Associate'Planner
Enclosure: Memorandum from Jeanie McConnell dated November 8, 2011
Cc: File No. PLN20110063
Page 3 of 3
0
E
Date:
To:
From:
Subject:
MEMORANDUM
November 8; 2011
Jen Machuga, Planner
Jeanie McConnell, Engineering Program Manager
PLN20110063
21401-72nd Ave W — Kruger Orthopedic Clinic
Engineering has reviewed and approved the subject design review application with the
following comments noted to be noted in the staff report.
1) Compliance with Engineering codes and construction standards will be reviewed with the
building permit application for development of the site.
2) Approval of the design review phase of the project does not constitute approval of the
improvements as shown on the submitted plans.
3) Applicant is encouraged, wherever feasible, to incorporate pervious pavements, rain
gardens and/or other low impact development techniques into the project design.
Thank you.
City of Edmonds
( - Message 0 Page I of I
McConnell, Jeanie
From: McConnell, Jeanie
Sent: Tuesday, December 06, 2011 3:45 PM
To: 'Scott Shanks'
Subject: Premier Ortho - TI
Scott,
Please find attached plan review comments from the Engineering Division in review of the TI for Premier
Ortho.
Regards,
Jeanie
JEANIE McCONNELL I Engineering Program Manager I mcconnelloci.edmonds.wa.us
Public Works Department I Engineering Division 1 121 5th Ave N I Edmonds, WA 98020
City of Edmonds I www.edmondswa.gov I Tel: 425.771.0220 1 Fax: 425.771.0221
12/6/2011
ii 9 0
oi� ED 40 CITY OF EDMONDS
A
PLAN REVIEW COMMENTS
ENGINEERING DIVISION
-0220
199() (425)771
City Website: www.edmondswa. go
DATE: December 6, 2011
TO: Scott Shanks
scott@fwdsinc.com
FROM: Jeanie McConnell, Engineering Program Manager
RE: Application #: bld20110816
Project: Premier Orthopedic Group — Tenant Improvement
Project Address: 2140172 "d Ave W
During review of the above noted application, it was found that the following information,
corrections, or clarifications are needed. Please submit three (3) sets of revised plans/documents
with a written response to each of the items below to Marie Harrison.
City of Edmonds handouts, standard details and development code can be referenced on the City
website.
NOTE: Shell & Core, Civils were reviewed under separate permit - 01d20110815.
Review I — November 16, 2011
Review 2 — December 6, 2011
AO.3 — REFERENCE SITE PLAN
1. ok
2. ok
P01 — LEGEND, SCHEDULES & GENERAL NOTES
I . ok
2. 12/6/2011 — Thank you for adding the vent piping to the plans. You are correct that the
backwater valve is not required, however, in this location installation would be
appropriate and beneficial to the owner. Please confirm that the owner does not desire a
backwater valve.
11/16/11 comment - Detail 1. 1 shows a 2" vent on the 4" waste outlet pipe. In lieu of the vent
installation of a backwater valve seems appropriate. This would prevent any sewer backup from
entering the parking garage through this structure.
bld20llO8l6-Premier—Ortho-TI-E2.doc Page I of 2
P02 — FOUNDATION PLAN — WASTE AND VENT
I . A
2. A
3. A
4. 12/6/2011 — If a backwater valve is installed per comment 2 above, please show on the
plans.
I 1/ 16/11 comment - Please show location of backwater valve on the outlet side of the oil/water
separator should you choose to install one.
5. 12/6/2011 — Please show all floor drain locations. Will they be D5 drains? If so, please
indicate as such on the plans.
I 1/ 16/11 comment - The oil/water separator is the only drainage basin that has been shown on
this plan sheet. There are other locations throughout the garage where it appears as though catch
basins should be/could be installed ... please clarify and add basins where necessary.
P03 — LEVEL 1 FLOOR PLAN — WASTE AND VENT
1. A
2. 12/6/2011 — For clarification a note has been added to the plan.
I 1/ 16/11 comment - The oil/water separator is shown on this plan sheet, but it is not at the level
of the waste lines that are shown. Please grey out/dash line type.
PO4 — LEVEL 2 FLOOR PLAN — WASTE AND VENT
1. A
Please contact me at 425-771-0220 or by e-mail at mcconnell(&,ci.edmonds.wa.us if you have
specific questions regarding these plan corrections.
bld20llO8l6-Premier—Ortho-TI-E2.doc Page 2 of 2
Landscape Bid for Premier Orthopedic Grou D20110815) Page I of I
Machuga,Jen
From:
Jim Uimw@ddgarchitects.com]
Sent:
Monday, December 12, 2011 11:23 AM
To:
Machuga,Jen
Cc:
Scott Shanks
Subject: RE: Landscape Bid for Premier Orthopedic Group (BLD20110815)
Jen,
I have attached the Contractor's landscape bid. Let me know if it has enough information to establish
the Bond amount.
Jim Wieben
From: Machuga, Jen [mailto: Mach uga@ci.edmonds.wa. us]
Sent: Friday, December 09, 20114:57 PM
To: jimw@ddgarchitects.com
Cc: Scott Shanks
Subject: Landscape Bid for Premier Orthopedic Group (BLD20110815)
Hi Jim,
I see the letter from Pennon in your resubmittal for the Premier Orthopedic building permit application
regarding the value of the landscaping and irrigation scopes of work for the project, but I'm wondering if
you've happened to get a landscape bid yet. I said in my previous comments that the bid wouldn't be
necessary until the time of our final Planning inspection for purposes of calculating the maintenance bond,
but I completely forgot that I need the bid amount for calculating our landscaping inspection fee.
If you happen to have a bid or if you could easily obtain one, would you mind emailing it to me? If it's not
possible, let me know, and I'll see what we can do (it definitely won't be something that will hold up the
issuance of your permit).
Thanks, and sorry for my mistake on this!
Jen
Jennifer Machuga, Associate Planner
City of Edmonds, Planning Division
121 - 5th Avenue North
Edmonds, WA 98020
(425) 771-0220 ext. 1224
Machuga(&ci.edmonds.wa.us
12/12/2011
P.0 Box 1683
Woodinville, WA 98072
Phone (425)487-0077
. Fax (425)481-9384
Pictqresquel,and.corq
Date:. 11-29-11
Job Name — Premier Orthopedic Group
General Contractor Pennon Construction
Bid Item Landscave + Irrigation
Section(s) (32000)
Bid By Matt King
PER PLANS AND SPECS: Pages
Includes
Plants.
Landscaping $22,100,
8' Tre ' e st * akes. Im"gation. $4,500
Tree Wrap. Total $26,600
0" 5-way import topsoil. Plus Sales Tax
T'Mediurn Fine Bark Mulch.
Weed fabric to newly. planted areas.
Rototill.
Fertilizer
Maintlain'landscape until final acceptanc e.
Digging and re -planting of 5 Sweetgum trees is budgeted at $600. -No guaranitee that 100% of these will survive.
Pruning of existing trees that overhang property% as noted in Plant notes."in work package #7 budgeted at $400;,
Alternates & Assumptions
4" caliper Sweetgum replaced at $400 per tree. (_P0 C
2 year Irrigation Maintenance $450
NO'LANDSCAPE PLANTE - RS OR MATERIAL IN BID. None seen.
Exclu'sion: s Exclusions
Site grading Maintenance after final acceptance
Fences Waterproofing
Concrete
Water Meter
Drain, Power to Irrigation Controller
Pgc�
- END OF BID PROPOSAL -
ANY QUESTIONS OR CLARIFICATIONS CONTACT MATT KING
CELL (206)714-4593
OFFICE (425)487-0077,
EMAIL - matt@pi C-turesiqueiarid.corn
THANK YOU FOR THE OPPORTUNITY!
C_'. to, JQL'.
OPP
-fS *,-- 1% 4 64 w6,,c1%*-wcx- P44 -i I?
C,41P V 1?011
le6i �VIAIG,0'
UP
IS 70 *q 6,tc( per
Site Improvement Bond Quantity Worksheet Web date: 12/02/2008
La King County
Department of Development & Environmental Services
900 Oakesdale Avenue Southwest
Renton, Washington 98057-5212 For alternate formats, call 206-296-6600.
206-296-6600 TTY 206-296-7217
Project Name: Premier orthopedic Group Date: 12/02/11
Location: 21401 72nd Ave W., Edmonds, WA 98020 ProjectNo.: bld#2011-0815
0 Activity No.: 1sa job #5311
Clearing greater than or equal to 5,000 board feet of timber?
yes x no
If yes,
Forest Practice Permit Number:
(RCW 76.09)
Note: All prices include labor, equipment, materials, overhead and
profit. Prices are from RS Means data adjusted for the Seattle area
or from local sources if not included in the RS Means database.
1&kftftfW UST
1� 4*1 -0 IT-7, (0 q - S-Z)
Page 1 of 9 14 4/0 1z a T #to
*1
AtAxw
�O
li-wks-sbq.xls
RECEIVED
DEC - 7 20.11
DEVELOPMENT SUMCES CTr,
CITY OF EDMONDS
Unit prices updated: 02/12/02
Version: 11/26/2008
Report Date: 12/02/2008
0
0
Site Improvement Bond Quantity Worksheet Web date: 12/02/2008
Reference #
Unit'
Price
Unit
Quantity
#of
Applications
Cost
EROSIQN/SEDIMENT CONTROL
Number
Backfill & compaction -embankment
ESC-1
$ 5.62
CY
Check dams, 4" minus rock
ESC-2
SWDM 5.4.6.3
$ 67.51
Each
Crushed surfacing 1 1/4" minus
ESC-3
WSDOT 9-03.9(3)
$ 85.45
CY
Ditching
ESC-4
$ 8.08
CY
Excavation -bulk
ESC-6
$ 1.50
CY
Fence, silt
ESC-6
SWIDM 5.4.3.1
$ 1.38
LF
720
994
Fence, Temporary (NGPE)
ESC-7
$ 1.38
LF
Hydroseeding
ESC-8
SWIDM 5.4.2.4
$ 0.59
SY
Jute Mesh
ESC-9
SWI)M 5.4.2.2
$ 1.45
SY
Mulch, by hand, straw, 3" deep
ESC-1 0
SWIDM 5.4.2.1
$ 2.01
SY
Mulch, by machine, straw, 2" deep
ESC-1 I
SWI)M 5.4.2.1
$ 0.53
SY
Piping, temporary, CPP, 6"
ESC-1 2
$ 10.70
LF
Piping, temporary, CPP, 8"
ESC-1 3
$ 16.10
LF
Piping, temporary, CPP, 12"
ESC-14
$ 20.70
LF
Plastic covering, 6mm thick, sandbagged
ESC-15
SWIDM 5.4.2.3
$ 2.30
SY
Rip Rap, machine placed; slopes
ESC-16
WSIDOT 9-13.1(2)
$ 39.08
CY
Rock Construction Entrance, 50'xl5'xl'
ESC-1 7
SWIDM 5.4.4.1
$ 1,464.34
Each
1
1,464
Rock Construction Entrance, 100'xl5'xl'
ESC-18
SWIDM 5.4.4.1
$ 2,928.68
Each
Sediment pond riser assembly
ESC-19
SWIDM 5.4.5.2
$ 1,949.38
Each
Sediment trap, 5' high berm
ESC-20
SWDM 5.4.5.1
$ 17.91
LF
Sed. trap, 5'high, riprapped spillway berm section
ESC-21
SWIDM 5.4.5.1
$ 68.54
LF
Seeding, by hand
Sodding, 1" deep, level ground
ESC-22
SWDM 5.4.2.4
$ 0.51
SY
ESC-23
SWDM 5.4.2.5
$ 6.03
SY
Sodding, 1" deep, sloped ground
ESC-24
SWDM 5.4.2.5
$ 7.45
SY
TESC Supervisor
ESC-25
$ 74.75
HR
8
599
Water truck, dust control
ESC-26
SWDM 5.4.7
$ 97.75
HR
2
200
WRITE'-4N-ITEMS.'****- (S66 6692 9
check dams
50.00
Each
9
450
sediment trap
I
113�
-1&0
r interceptor ditch
2
lf
210-
420
Page 2 of 9
li-wks-sbq.xls
ESC SUBTOTAL:
30% CONTINGENCY & MOBILIZATION:
ESC TOTAL:
COLUMN:
$ 4,A?l� - ta'�71 —
$ 1,A-T3 -
$ 6 —24-T-
A
Unit prices updated: 02/12/02
Version: 11/26/2008
Report Date: 12/02/2008
1�1
Site Improvement Bond Quantity Worksheet
Web date: 12/02/2008
Right -of -Way
,-Future Public
Rmd,improvemen ti
Drainage Facilities
Private
Improvements
Quantity Completed
(Bond Reduction)*
Quant.
��Iete]
Cost
UnitiPrice.
Unit
0 . uant. Cost
Q e u . ant.
Cost
uant.T G
Q ost
GENERAL ITEMS
No.
Backfill & Compaction- embankment
GI-1
$ 5.62
CY
Backfill & Compaction- trench
GI-2
$ 8.53
CY
Clear/Remove Brush, by hand
G1-3
$ 0.36
SY
Clearing/Grubbing/Tree Removal
G1-4
$ 8,876.16
Acre
Excavation - bulk
GI-51
$ 1.50
CY
Excavation - Trench
G1-6
$ 4.06
CY
Fencing, cedar, 6'high
G1-7
$ 18.55
LF
Fencing, chain link, vinyl coated, 6' hig
G1-8
$ 13.44
LF
Fencing, chain link, gate, vinyl coated,
Gi - 9
$ 1,271.81
Each
Fencing, split rail, 3' high
G1 - 10
$ 12.12
LF
Fill & compact - common barrow
GI - 111
$ 22.57
CY
Fill & compact - gravel base
Gi - 12
$ 25.48
CY
Fill & compact - screened topsoil
G1 - 13
$ 37.85
CY
Gabion, 12"deep, stone filled mesh
Gi - 14
$ 54.31
SY
Gabion, 18" deep, stone filled mesh
Gi - 15
$ 74.85
SY
Gabion, 36" deep, stone filled mesh
G1 - 16
$ 132.48
SY
Grading, fine, by hand
GI - 171
$ 2.02
SY
Grading, fine, with grader
G1 - 18
$ 0.95
sy
204
194
Monuments, Slong
GI - 19
$ 135.13
Each
Sensitive Areas Sign
G1 - 20
$ 2.88
Each
Sodding, 1 " deep, sloped ground
G1 - 21
$ 7.46
SY
Surveying, line & grade
GI - 22
$ 788.26
Day
Surveying, lot location/lines
G1 - 231
$ 1,556.64
Acre
Traffic control crew ( 2 flaggers
G1 - 24
$ 85.18
FIR
40
3,407
Trail, 4" chipped wood
G1 - 25
$ 7.59
SY
Trail, 4" crushed cinder
G1 - 26
$ 8.33
SY
Trail, 4" top course
GI - 27
$ 8.19
SY
Wall, retaining, concrete
GI - 28
$ 44.161
SF
I
lWall, rockery
IGI - 291
$ 9.491
SF
I
Page 3 of 9
*KCC 27A authorizes only one bond reduction.
li-wks-sbq.xis
SUBTOTAL
3,601
Unit prices updated: 02/12/02
Version: 11/26/08
Report Date: 12/02/2008
0
Site Improvement Bond Quantity Worksheet
Web date: 12/02/2008
Existing
Rlgh�of-wiy
Future Public
a
Ro dArnproverents
&: drilriag'e Fa Cillitles.
Private
mprovernents'
',Bond Reduction*
ouaht.
ornplet'
cost
allhi#P.-H-66W
W Unft
_106-5W-*Ff-"�� --Vc6sV�- -
Qua,h*t.- ;—Cosf
Q U 7arit 7 cost
AC Grinding, 4'wide machine < 1 000sy
RI-1
$ 28.00
SY
AC Grinding, 4'wide machine 1000-200
RI - 2
$ 15.00
SY
AC Grinding, 4'wide machine > 2000sy
RI-3
$ 7.00
'SY
AC Removal/Disposal/Repair
RI-4
$ 67.50
SY
4,.22-51
Barricade, type I
Rl - 5.
$ 30.03
LF
Barricade, type Ill ( Permanent
RI-61
$ 45.05
LF
Curb & Gutter, rolled
RI-7
$ 17.00
LF
Curb & Gutter, vertical
RI-8
$ 12.50
LF
285
.3, bb.3
Curb and Gutter, demolition and diEE22�
I Rl - 9
$ 18.00
LF
C;
5,130
Curb, extruded asphalt
Rl - 10
$ 5.50
LF
Curb, extruded concrete
Rl - 11
$ 7.00
LF
Sawcut, asphalt, 3" depth
Rl - 121
$ 1.85
LF
Sawcut, concrete, per V depth
RI - 13
$ 1.69
LF
5
8
Sealant, asphalt
RI - 14
$ 1.25
LF
Shoulder, AC, ( see AC road unit price
RI - 15
$ -
SY
Shoulder, gravel, 4" thick
Rl - 16
$ 15.00
SY
Sidewalk, 4" thick
RI - 17
$ 35.00
SY
Sidewalk, 4" thick, dernolition and dispo!
RI - 181
$ 29.50
SY
Sidewalk, 5" thick
Rl - 19
$ 38.50
SY
1
W F,3Try 9�
10
Sidewalk, 5" thick, demolition and dispo
R1 - 20
$ 37.50
SY
Sign, handicap
RI - 21
$ 85.28
Each
Striping, per stall
RI - 22
$ 5.82
Each
Striping, thermoplastic, ( for crosswalk )
Rl - 23
$ 2.38
SF
IStriping, 4" reflectorized line
JR1 - 241
$ 0.25
1 LF
Page 4 of 9
*KCC 27A authorizes only one bond reduction.
li-wks-sbq.xis
SUBTOTAL 3, �2
111gaz ;F0-
Unit prices updated: 02/12/02
Version: 11/26/08
Report Date: 12/02/2008
0
F—
L'I
Site Improvement Bond Quantity Worksheet
Web date: 12/02/2008
tx1iting
Right-of4ay,
Future Public
Roa d'Impr6vements
&Drainane Facilities
Private
Improvements
Bond Reduction*
Quant.
Compleiel
Cost
n
U it,Price
Unit
Qu6nt.�,.� Cost
�:Ouarit.'; Cost
Qdant. co St
W(JX6V6URFAC1NdZ - :5 base '54t p,c'o'u q),. For!'G�,KCRS(6�5",F46�k=5!�b�tq�,'
For KCRS'93, (additional 2.5" base) ad
RS - 1
$ 3.60
SY
AC Overlay, 1.5" AC
RS - 2
$ 11.25
SY
AC Overlay, 2" AC
RS - 3
$ 15.00
SY
AC Road, 2", 4" rock, First 2500 SY
RS - 4
$ 21.00
Sy
AC Road, 2", 4" rock, Qty. over 2500SY
RS - 5
$ 19.00
SY
AC Road, 3", 4" rock, First 2500 SY
RS - 6
$ 23.30
SY
AC Road, 3", 4" rock, Qty. over 2500 SN
RS - 7
$ 21.00
SY
AC Road, 5", First 2500 SY
RS - 8
$ 27.60
SY
AC Road, 5", Qty. Over 2500 SY
RS - 9
$ 25.00
SY
AC Road, 6", First 2500 SY
RS - 1 C
$ 33.10
SY
AC Road, 6", Qty. Over 2500 SY
RS - 11
$ 30.00
SY
Asphalt Treated Base; 4" thick
RS - 1
$ 20.00
SY
Gravel Road, 4" rock, First 2500 SY
RS - 1
$ 15.00
SY
Gravel Road, 4" rock, Qty. over 2500 S)RS
- 1
8.50
SY
PCC Road, 5", no base, over 2500 SY
RS - 1
$ 27.00
SY
PCC Road, 6", no base, over 2500 SY
RS - 1
$ 25.50
SY
Thickened Edge
RS - 1A
$ 8.60
1 LF
Page 5 of 9
*KCC 27A authorizes only one bond reduction.
li-wks-sbq.xls
SUBTOTAL
1,323
Unit prices updated: 02/12/02
Version: 11/26/08
Report Date: 12/02/2008
0
Site Improvement Bond Quantity Worksheet
Web date: 12/02/2008
Existing
,Riqlht�of4ay
�'Future Public
Road Improvements
& Drainage Facilities
Private
Improvements
Bond.Reduction*
Quant.
Complet
e,� Cost
unit Price
Unit
,Cost
n:-
-Qua t� ,, �, :''Cost"-,
0 Cost,
gRAINA:G�t"(CPP orrugated Pla'stic Pipe; NI ae
C 2 or Equiv I For Culvert pric6ij:A ra a of 4'cover was assumed. -Ass me perfo ad PVC is same price as solid pipe.
Access Road, R/D
D - 1
$ 21.00
SY
Bollards - fixed
D-2
$ 240.74.
Each
Bollards - removable
D - 3
$ 452.34
Each
* (CBs include frame and lid)
CB Type I
D-4
$ 1,257.64
Each
3
3,773
22A 11V,
ia
CB Type IL
D - 5
$ 1,433.59
Each
CB Type 11, 48" diameter
D-6
$ 2,033.57
Each
3,000
for additional depth over 4'
D-7
$ 436.52
FT
CB Type 11, 54" diameter
D-8
$ 2,192.54
Each
for additional depth over 4'
D-9
$ 486.53
FT
I
CB Type 11, 60" diameter
D-10
$ 2,351.52
Each
for additional depth over 4'
D-11
$ 536.54
FT
CB Type 11, 72" diameter
D - 12
$ 3,212.64
Each
for additional depth over 4'
D - 13
$ 692.21
FT
Through -curb Inlet Framework (Add)
D - 14
$ 366.09
Each
Cleanout, PVC, 4"
D - 151
$ 130.55
Each
Cleanout, PVC, 6"
D - 16
$ 174.90
Each
Cleanout, PVC, 8"
D - 17
$ 224.19
Each
Culvert, PVC, 4"
D - 18
$ 8.64
LF
Culvert, PVC, 6"
D - 19
$ 12.60
LF
384
4,610
Culvert, PVC, 8"
D - 20
$ 13.33
LF
61
813
Culvert, PVC, 12"
D - 211
$ 21.77
LF
JAS
V&
Culvert, CMP, 8"
D - 22
$ 17.25
LF
Culvert, CMP, 12"
D - 23
$ 26.45
LF
Culvert, CMP, 15"
D - 24
$ 32.73
LF
Culvert, CMP, 18"
D-25
$ 37.74
LF
Culvert, CMP, 24"
D - 26
$ 53.33
LF
Culvert, CMP, 30"
D - 271
$ 71.45
LF
Culvert, CMP, 36"
D - 28
$ 112.11
LF
Culvert, CMP, 48"
D - 29
$ 140.83
LF
Culvert, CMP, 60"
D - 30
$ 235.45
LF
Culvert, CMP, 72"
D - 31
$ 302.581
LF I
Page 6 of 9
*KCC 27A authorizes only one bond reduction.
li-wks-sbq.xls
SUBTOTAL
4W.1-1
9
Unit prices updated: 02/12/02
Version: 11/26/08
Report Date: 12/02/2008
0
Site Improvement Bond Quantity Worksheet
Web date: 12/0212008
DRAINAGE'CONTINUED.
Existing
Right-of-way
Future Public
Road Irriprovernents
& Drainage Facilities
Private
Improvements
Bond Reduction*
QuanL
Completei
cost:
Unit Price',,',,'
",',Unit
�Quiht.
Cost,,
Quant�.
cost
Quant.
Cost
Culvert, Concrete, 8"
D - 321
$ 21.02
LF
Culvert, Concrete, 12"
D - 331
$ 30.05
LF
Culvert, Concrete, 15"
D - 34
$ 37.34
LF
Culvert, Concrete, 18"
D - 35
$ 44.51
LF
Culvert, Concrete, 24"
D - 36
$ 61.07
LF
Culvert, Concrete, 30"
D - 37
$ 104.18
LF
Culvert, Concrete, 36"
D - 38
$ 137.63
LF
Culvert, Concrete, 42"
D - 391
$ 158.42
LF
Culvert, Concrete, 48"
D - 40
$ 175.94
LF
Culvert, CPP, 6"
D - 41
$ 10.70
LF
Culvert, CPP, 8"
D - 42
$ 16.10
LF
WW4,412P,—tr—�
2 6
4. 2949
1! F
Culvert, CPP, 15"
D - 44
$ 23.00
LF
Culvert, CPP, 18"
D - 451
$ 27.60
LF
Culvert, CPP, 24"
0-46
$ 36.80
LF
Culvert, CPP, 30".
D - 47
$ 48.30
LF
Culvert, CPP, 36"
D - 48
$ 55.20
LF
Ditching
D - 49
$ 8.08
CY
Flow Dispersal Trench (1,436 base+)
D - 50
$ 25.99
LF
French Drain (3'depth)
D - 511
$ 22.60
LF
Geotextile, laid in trench, polypro�ylene
D - 52
$ 2.40
SY
Infiltration pond testing
D - 53
$ 74.75
HR
Mid -tank Access Riser, 48" dia, 6'deep
0-54
$ 1,605.40
Each
Pond Overflow Spillway
D - 55
$ 14.01
SY
Restrictor/Oil Separator, 12" ( 8
D - 56
$ 1,045.19
Each
Restrictor/Oil Separator, 15"
D - 571
$ 1,095.56
Each
Restrictor/Oil Separator, 18"
D - 58
$ 1,146.16
Each
Riprap, placed
D - 59
$ 39.08
CY
jEach
Tank End Reducer (36" diameter)
D - 60
$ 1,000.50
Trash Rack, 12"
D - 61
$ 211.97
Each
Trash Rack, 15'
D - 62
$ 237.27
Each
Trash Rack, 18"
1 D - 631
$ 268.89
Each
Trash Rack, 21"
1 D - 641
$ 306.841
Each
Page 7 of 9
*KCC 27A authorizes only one bond reduction.
li-wks-sbq.xis
2,
SUBTOTAL
1,200
Unit prices updated: 02/12/02
Version: 11/26/08
Report Date: 12102/2008
0
Site Improvement Bond Quantity Worksheet
Web date: 12/02/2008
Existing
Right-of-way
'Future Public
Road Improvements
& Drainrge Facilities
Private
improvements
Bond Reduction*
Quant.
lComplet
cost
Unit Price
Unit
_j
Pride
Quant. Cost
Quant. Cost
PARKING LOT SURFACING
No.
2" AC. 2" top course rock & 4" borrow
PL - 1
$ 21.00
SY
2" AC, 1.5" top course & 2.5" base cou
PL - 2
$ 28.00
SY
4" select borrow
PL - 3
$ 4.55
SY
1.5" top course rock & 2.5" base course
PL-4
$ 11.41
SY
UTILITY $)CiLkES,&�8TREET','�LIOH.,'TiNG- mpanied,6francihiseUtilit I !s Cost . Stet I ement
Mtypble-relbdatonoos mustbe,ac&
Utility Pole(s) Relocation
UP-1
Lump Sum
Street Light Poles w/Luminaires
I UP-21
I Each
I
I
WkjttJ44T-tMg.��
(Such as detentiontwater quality vaults.
No.
vauit
WI - 1
Each
3 744tt
30, OC
0
ADA RAMP
WI - 2
SY
1 EA
900
FIRE LINE
VVI - 3
CY
LS
2750
SIDE SEWER
VM - 4
LF
LS
1200
STRIPING/PAINT
W - 51
FT
LS
S 0
WI - 6
WI - 7
WI - 8
WI - 9
W-10
SUBTOTAL
SUBTOTAL (SUM ALL PAGES):
30% CONTINGENCY & MOBILIZATION:
GRANDTOTA :
COLUMN:
-1W.0c -
Page 8 of 9
*KCC 27A authorizes only one bond reduction.
li-wks-sbq.xis
5,370
!�, 5 5 446-6.41
5
,4-, �O 2
B
-MIMA41
C
30,000
3,9�,7 3 -A[ 106.04
Itil 5q - 19
�� 01M.83
D E
Unit prices updated: 02/12/02
Version: 11/26/08
Report Date: 12/02/2008
Site Improvement Bond Quantity Worksheet Web date: 12/02/2008
Original bond computations prepared by:
Name: Jerry OConnell Date: 12/02/11
PE Registration Number: 34989 Tel.#:- 425-775-1591
Firm Name: LSA Enctineerincr 1sa # 5311
Address: 19217 36th ave w, #106, Lynnwood, WA 98036 Project No:
ROAD IMPROVEMENTS & DRAINAGE FACILITIES FINANCIAL GUARANTEE REQUIREMENTS
Stabilization/Erosion Sediment Control (ESC)
Existing Right -of -Way Improvements
Future Public Road Improvements & Drainage F
Private Improvements
Calculated Quantity Completed
Total Right -of Way and/or Site Restoration Bond*/**
(First $7,500 of bond* shall be cash.
Performance Bond* Amount (A+B+C+D) = TOTAL
Reduced Performance Bond* Total ***
Maintenance/Defect Bond* Total.
PERFORMANCE BOND*
AMOUNT
(A)
$
6,340
(B)
$
54,802
(C)
$
(D)
$
40,673
(A+B)
$
61,142
(T)
$
101,815
Minimum bond* amount is $1000
BOND*AMOUNT
REQUIRED AT RECORDING OR
TEMPORARY OCCUPANCY ...
(E) $
x 0.30 $
(T-E) $
Use larger of Tx3O% or (I -E.
OR
0 NAME OF PERSON PREPARING BOND* REDUCTION: Date:
PUBLIC ROAD & DRAINAGE
MAINTENANCE/DEFECT BOND*
(B+C) x 54, 8 02x. 2 5
0.25 = $ 1-; 7()l -
NOTE: The word "bond" as used in this document means any financial guarantee acceptable to King County.
NOTE: KCC 27A authorizes right of way and site restoration bonds to be combined when both are required.
The restoration requirement shall include the total cost for all TESC as a minimum, not a maximum. In addition, corrective work, both on- and off -site needs to be included.
Quantities shall reflect worse case scenarios not just minimum requirements. For example, if a salmonid stream may be damaged, some estimated costs for restoration
needs to be reflected in this amount. The 30% contingency and mobilizaiion costs are computed in this quantity.
NOTE: Per KCC 27A, total bond amounts remaining after reduction shall not be less than 30% of the original amount (T) or as revised by major design changes.
SURETY BOND RIDER NOTE: If a bond rider is used, minimum additional performance bond shall be I(C+D)-E
REQUIRED BOND* AMOUNTS ARE SUBJECT TO REVIEW AND MODIFICATION BY ODES
Page 9 of 9 Unit prices updated: 02/12/02
Check out the DDES Web site at.wwwkingcounty-goylloermits Version: 11/26/08
li-wks-sbq.xls Report Date: 12/02/2008
Lovell-Sauerland and Associates, Inc. Phone: 425-775-1591
19217 - 361h Avenue West, Suite 106
LM N E LSAEngineering.com
Lynnwood, Washington 98036
Memorandum File No: 5311
Date: December 07, 2011
To: Jeanie McConnell, City of Edmonds
From: Jerry OConnell
Subject: Premier Orthopedic Group BLD# 2011-0815-Resonse letter to
review comments I
The following list summarizes our response to the City's review comments dated December 5,
2011 for the above referenced project.
GENERAL RECEIVED
1. Revised cost estimate to add items.
DEC - 7 2011
SHEET C1 — SITE PLAN DMWwENT sEFMCES CTR-
20. Provided separate tap & meter for irrigation cl-rY OF EDMONDS
25. Showed valves on cl & c4
31. Revised landscaping at curb ramp
SHEET C4-frontage plan
4. Revised to add striping & curb painting notes.
SHEET C8 — TRAFFIC CONTROL PLAN
1. Left note as is ...... owner to obtain bldg permit prior to tcp approval.
I have enclosed 3 sets of the revised plans and cost estimate for your next review. Please let
me know if I can provide anything else to help expedite your review.
Best Regards,
Jerry Conne
531 1trn-3RD-response.docx
Page I of I
McConnell, Jeanie
From:
McConnell, Jeanie
Sent:
Tuesday, December 06, 2011 9:15 AM
To:
'Jerry O'Connell'
Cc: 'jimw@ddgarchitects.com'; Harrison, Marie
Subject: Premier Ortho - engineering review
12/6/2011
0 9
CITY OF EDMONDS
PLAN REVIEW COMMENTS
ENGINEERING DIVISION
(425) 771-0220
CityWebsite: www.edmondswa.go
DATE: December 5, 2011
TO: Jerry O'Connell
JerryO@Isaengineering.com
FROM: Jeanie McConnell, Engineering Program Manager
RE: Application #: bld20110815
Project: Premier Orthopedic Group — Shell & Core, Civil Improvements
Project Address: 2140172 nd Ave W
During review of the above noted application, it was found that the following information,
corrections, or clarifications are needed. Please submit three (3) sets of revised plans/documents
with a written response to each of the items below to Marie Harrison.
City of Edmonds handouts, standard details and development code can be referenced on the City
website.
Review I —November 16, 2011
Review 2 — December 5,2011
GENERAL
12/5/11 — Thank you for providing a cost estimate for the project. Please revise the
estimate to include new curb ramp with truncated domes, installation of the fire line and
associated valves, sewer tap on City main and striping within the right-of-way.
I 1/ 16/11 comment - Please provide an itemized engineers cost estimate, including units and unit
prices, for both on -site and off -site (right-of-way) improvements, including traffic control. The
City prefers use of the King County Site Improvement Bond Quantity Worksheet.
o A bond is required to be placed for all right-of-way improvements. The amount of the bond
will be based on 120% of the City approved estimate for all right-of-way improvements.
The City will infonn you of the appropriate bond amount after review of the cost estimate.
Bond forms can be obtained from Marie Harrison, Permit Coordinator — 425-771-0220 or
Harrison@ci.edmonds.wa.us
o Inspection fees for this project will be calculated at 2.2% of the 120% City approved
estimate for all improvements.
2. ok
3. ok
4. ok
5. ok
bid2011O8l5-Premier—Ortho-E2.doc Page I of 4
0
0
STORM DRAINAGE REPORT
OK
A-101 — SITE PLAN
1. A
2. A
3. A
A-111 — FIRST FLOOR PLAN
1. A
2. A
3. A
L-1.0 — LANDSCAPE PLAN
1. A
2. A
3. A
SHEET C1 — SITE DEVELOPMENT, DRAINAGE AND UTILITY PLAN
4. A
5. A
6. A
7. A
8. A
9. A
10. A
11. A
12. A
13. A
14. A
15. A
16. A
17. A
18. A
19. A
100 2/5/2011 — If the applicant chooses, the irrigation system could be tapped off the backside
of the water meter on private property, but a meter could not be provided. A separate tap
off the City water main would be required to provide a separate meter. Please revise plans
accordingly.
I 1/ 16/11 comment - Plans indicate a separate water meter and tap off the domestic feed for the
irrigation system. If the preference is to have the irrigation system billed separately from the
domestic water then a separate tap off the main will be required. Please note, sewer charges are
based off of domestic water consumption, so having a separate irrigation meter could reduce the
sewer charges for the site. The City doesn't offer a deduct method for this.
21. A
bld2011O8l5-Premier—Ortho-E2.doc Page 2 of 4
0 0
22. ok
23. ok
24. ok
65WJ12/5/2011 - Sheet C4, Frontage Improvement Plan, now includes the requirement for in
line valves on the main line and references the appropriate standard detail. Please revise
sheets C1 and C4 to show the valves in plan view.
11/16/11 comment - The City will not permit a wet tap for the 6" fire line connection to the City
main. Two in -line valves shall be installed on the City water main to either side of the 6" fire
line connection. Please reference and incorporate city standard detail E7.18. 1. Please also add
parts call outs to the plans for size of valves, fittings, etc.
26. ok
27. ok
28. ok
29. ok
30. ok
09-1-1 12/5/2011 - Thank you for aligning the new curb ramp with the sidewalk. Please revise
plans to show a landscape buffer along the west edge of the sidewalk versus concrete. The
small section that appears to be an extension of the private walkway should also be revised
to be landscaping.
I 1/ 16/11 comment - The new curb ramp on the south end of the proj ect should stay in alignment
with sidewalk to the north. Please reference and incorporate WSDOT standard detail F-40.16-
01 for single direction curb ramps. This detail also shows the landscape buffer.
32. ok
33. ok
34. ok
35. ok
SHEET C2 - GRADING AND EROSION CONTROL (SWPPP) PLAN
1. ok
2. ok
3. ok
SHEET C3 - ROAD SECTION AND PROFILE
1. ok
2. ok
3. ok
SHEET C4 - FRONTAGE IMPROVEMENT PLAN (previously notes and details)
1. ok
2. ok
3. ok
JAL,Please revise plans to include restoration (re -striping) of existing painted center line in area of
trench patches, relocation of bus sign, and yellow curbing to indicate no parking as needed. At a
minimum, the curb shall be painted yellow 5' to either side of the driveway approach.
bld2011O8l5-Premier—Ortho-E2.doc Page 3 of 4
0 0
Additional distance may be required for sight distance purposes. The curb should also be
painted yellow in the area of the bus stop.
Please note, there have been previous discussions on how to designate the area in front of the
trash enclosure access. The curb could be painted yellow to indicate no parking or a sign could
be installed to limit the parking to delivery vehicles for example. If a sign is desired, please
submit your preferred sign verbiage to the City Traffic Engineer for approval.
SHEET C5 — NOTES AND DETAILS
1. ok
2. ok
SHEET I of I — TRAFFIC CONTROL PLAN
12/5/2011 — A note was added to the plans stating "the contractor shall submit a separate
specific traffic control plan for each construction phase. Plans shall be submitted and
approved by the City prior to starting construction on each phase."
Typically, the building permit for a project is not issued until we have received a complete
traffic control plan. Reviewing and approving the TCP's at this phase eliminates delays
during construction. Please confirm that it is your desire is to obtain a building permit ahead
of submitting the required TCP's.
I I / 16/11 comments -
I . Please provide separate traffic control plans for the various phases of construction to address
utility tie-in's, frontage improvements, concrete pours on site, materials delivery, etc.
2. Where lane shifts are proposed, please show the full spectrum of 72 nd Ave W to ensure 10-foot
minimum lane widths will be maintained.
3. Placement of cones, spacing, taper, etc. shall be included.
4. Sidewalk closure signage shall be provided as appropriate.
5. Coordination with Community Transit will be required for temp or permanent bus stop
relocation.
6. Parking and sidewalk closures in excess of 72-hours shall be approved by the City and
disruption fees will apply. Please clearly state your intent and provide a request in writing for
such closure.
Please contact me at 425-771-0220 or by e-mail at mcconnell(iDci.edmonds.wa.us if you have
specific questions regarding these plan corrections.
bld20llO8l5-Premier—Ortho-E2.doc Page 4 of 4
7T�
Page I of 1
McConnell, Jeanie
From: Jerry O'Connell [JerryO@Isaengineering.com]
Sent: Friday, December 02, 2011 10:01 AM
To: McConnell, Jeanie
Cc: Scott Shanks
Subject: premier orthpedic group bld#2011-0815
Jeanie,
Here is the completed bond form for your review.
Jerry O'Connell
LSA Engineering
Alderwood Business Campus
19217 36th Ave. W., #106- Bldg. 5
Lynnwood, WA 98036
phone: (425) 775-1591
email:
12/5/2011
0 0
Lovell-Sauerland and Associates, Inc. Phone: 425-775-1591
19217 - 361h Avenue West, Suite 106
LSAEngineering.com
Lynnwood, Washington 98036
Memorandum
File No: 5311
Date: November 21, 2011
To: Jeanie McConnell, City of Edmonds
From: Jerry OConnell
Subject: Premier Orthopedic Group BLD# 2011-0815-Resonse
letter to
review comments
The following list summarizes our response to the City's review comments dated November 16,
2011 for the above referenced project.
GENERAL
RESUB
1. Applicant to provide cost estimate.
2. Added construction sequence (c2)
NOV 2 12011
3. Added detail page callouts
4. Applicant is/has coordinated with CT.
BUILDING DEPARTMENT
CITY OF EDMONDS
5. Added testing note #6 to construction notes(cl)
STORM DRAINAGE REPORT
1. Revised calculations causing a revision to the vault. Revised plans/calculations/report
accordingly.
2. See vault detail C3 — per structural design, the vault will be incorporated into the garage
floor, thus should have sufficient ballast to overcome buoyancy effects.
3. Revised footers
SHEET C1 — SITE PLAN
4. Revised the plan set to include a larger scale frontage plan(c4) and separate items for
clarity.
5. Added demolition sheet (c9)
6. Added purveyor data
7. Added to construction notes see #7-cl.
8. Revised sheet index
9. Added cb data.
10. Revised pipe to 12"
11. Added note see c4
12. Revised cb#3 callout
13. Added construction note #9 — cl
531 1trn-response-to-2nd.docx
0
14. Added cb#5 data(cl)
15. Added footing drain connections(cl)
16. Revised roof drain connection (cl)
17. Called out wye (c4)
18. Showed cleanout (c4)
19. Added inverts (c4)
20. Revised water layout (c4)
21. Added construction note #10 (c4)
22. Added rpba (c4)
23. Added detail #e7.6-1 (c7)
24. Revised wm locations (c4)
25. Added detail (c7) and callout (c4)
26. Added construction note #11 (c4)
27. Added callout(c4) & detail (c7)
28. Added frontage plans (c4) & (c9)
29. Applicant wants driveway as is.
30. Added callout(c4)
31. Revised ramp(c4) added detail (c5)
32. Added callout (c4)
33. Added callout (c4)
34. Added callout (c4)
35. Revised callout (cl)
SHEET C2-GRADING & SWPPP
1. Moved tesc notes to c2
2. Revised legend
3. Added storage/material area
SHEET C3-ROAD SECTION & PROFILE
1. Revised to 12" pipe.
2. Revised cb#3 callout
3. Revised section a -a.
SHEET C4-NOTES & DETAILS
1. Revised general note #26
2. Added solid lid callout
3. Deleted removable plug.
531 ltrn-response-to-2nd.docx
0
SHEET C5-NOTES & DETAILS(new sht 6)
1. Revised detail to omit truncated domes
2. Replaced detail with wsdot detail(c5)
NEW SHEET C8 — TRAFFIC CONTROL PLAN
1 . Added note for contractor to provide pahsed plans
2. Added wsdot traffic control plan(tcp)
3. Added wsdot tcp
4. Added sidewalk closure signs
5. Added CT callout
6. Revised tcp not #9
I have enclosed 3 sets of the revised plans and drainage report for your next review. Please let
me know if I can provide you with anything else to help expedite your review.
Best Regards,
Je 4OConnell
531 1trn-response-to-2nd.docx
0 0
November 18, 2011
City of Edmonds
Steve Fisher, City of Edmonds Public Works
121 5h Avenue North
Edmonds, WA 98020
RE: Response to Plan Review Comments, dated 11-4-11
Plan Check # 2011-0815- Shell and Core, Solid Waste Collection Area
Dear Steve,
This response letter is accompanying copies of the revised Shell and Core permit drawings submitted for the Premier
Orthopedics Office Building to be located at 2140172 d Ave. W, Edmonds, WA. Based on the plan check comments
noted above, corrections have been made to the drawings originally submitted. All changes to the documents since the
original submittal to the City of Edmonds have been clouded including additional information not associated with City
comment letters. The responses to your comments are indicated on the drawings as follows:
General
A-1 11, First Floor plan has been modified to show dimensions of the Garbage / Recycle
Room, and the distance from the curb to the building has also been added to the plan. The
general location of the compactor unit has been added to the floor plan. The door size is 13%
2" wide x 10'-0" tall. Additional door information is found on Sheet A- 119. The wall
construction is of concrete block, is described in detail on Sheet A-1 15.
End of Solid Waste Comments Response
Please call me @ 206-571-5612 if you have any questions regarding the above responses.
Sincerely'
Jim Wieben, DDG Architects
RESUB
NOV 18 2011
WILDING DEPAMMEN-t
OM OF EDMONDS
16398 NE 851h St Suite 101 Redmond, WA 98052 Tel: (425) 285-9992
0 9
November 16, 2011
Donahou Design Group
City of Edmonds
Jeanie McConnell, Engineering Program Manager
121 5h Avenue North
Edmonds, WA 98020
RE: Response to Plan Review Comments, dated 11-16-11
Plan Check # 2011-0815- Shell and Core, Civil Improvements
Dear Jeanie,
This response letter is accompanying copies of the revised Shell and Core permit drawings submitted for the Premier
Orthopedics Office Building to be located at 21401 72 nd Ave. W, Edmonds, WA. Based on the plan check comments
noted above, corrections have been made to the drawings originally submitted. All changes to the documents since the
original submittal to the City of Edmonds have been clouded including additional information not associated with City
comment letters. The non -civil engineering responses to your comments are indicated on the drawings as follows:
A-101 — Site Plan
The Site Plan has been updated to illustrate the current frontage improvements along 72 d
Ave. West.
2. The notes relating to the frontage improvements along 72 nd Ave. W. have been deleted or
modified to direct the reader to the Civil Documentation for information regarding the
frontage improvements..
3. A note has been added to the drawing directing the reader to the Civil drawings for detailed
information relating to the Civil Engineering Documentation.
A-1 11 — First Floor Plan
The First Floor Plan has been updated to illustrate the current frontage improvements.
2. Detail 2, Sheet a- 102 has been modified to illustrate work outside of the public ROW.
3.
Detail 5, Sheet A- 102 has been modified to illustrate work outside of the public ROW.
RESUB
L-1.0 — Landscape Plan
NOV 17 2011
I . The Landscape drawing has been updated to show the irrigation meter DCVA. BUILDING DEpAfj'TMENT
2. The Requested note has been added to Sheet L 1.0 01-ry OF IjDMONDS
The irrigation system design will be restricted to private property and is noted on Sheet L 1.0.
16398 NE 85 1h St Suite 101 Redmond, WA 98052 Tel: (425) 285-9992
0 0
End of Non -Civil Engineering Comments Response
Please call me @ 206-571-5612 if you have any questions regarding the above responses.
Sincerely,
W ie
ieben, DDG Architects
November 16, 2011
Donahou Design Group
City of Edmonds
John Westfall, Fire Marshal
121 5h Avenue North
Edmonds, WA 98020
RE: Response to Plan Review Comments, dated 11-09-11
Plan Check # 2011-0815 Premier Orthopedic Shell
Dear John,
This response letter is accompanying copies of the revised building permit drawings submitted for the Premier
Orthopedics Office Building to be located at 21401 72d Ave. W, Edmonds, WA. Based on the plan check comments
noted above, corrections have been made to the drawings originally submitted. All changes to the documents since the
original submittal to the City of Edmonds have been clouded including additional information not associated with City
comment letters. The responses to your comments are indicated on the drawings as follows:
G-001 General Notes:
a. Note number I has been modified.
b. Note number 18 has been modified.
C. Note number 25 has been modified.
d. Note number 28 regarding the authorization for obtaining a Knox Box has been added to the
general notes.
Sheet G-001 Deferred Submittals:
The fire protection permit and the Fire Protection Footprint have been added to the list of
Deferred Submittals. The reference to the grease hood has been removed..
Sheet A-201 Comments:
3. A note has been added to the west elevation of the building identifying the specific
requirements of the addressing signage. A proposed location for the signage is identified on
the elevation, to be confirmed at a later date by the fire Marshal. RESUB
Sheet CS Comments NOV 17 2011
The compass headings for north have been added to the plans. BUILDING DEPARTMENT
OITY OF EDMONDS
The Exit travel distances have been identified with a directional arrow.
The gate in the vicinity of the NE comer has been removed. It was intended to act as a
removable vehicle barrier.
16398 NE 85 th St Suite 101 Redmond, WA 98052 Tel: (425) 285-9992
Sheet A-101 Comments
The tentative generator information is attached to this letter.
Sheet A-111 and A-112 Comments
The portable fire extinguisher locations have been added to all plan sheets.
Sheet A-111 and A117 Comments
The Door Schedule found on Sheet Al 19 has been updated to reference a Hollow Metal door
and eliminate the extraneous remarks callouts.
Sheet A-1 11 Comments
The requested note regarding the minimum temperature in the Fire Sprinkler Room has been
added.
Sheet A-111 Comments
The storage space will be used for the temporary storage of medical records. The area of the
storage was included in the S- I storage area noted on Sheet G-001.
Sheet A-1 11 and Al 19 Comments
The doors 105 and 106 are found on the Door Schedule on Sheet A-1 19. The doors located
on the third floor are a part of the Tenant Improvement scope of work and were not repeated.
Please reference the Tenant Improvement Door Schedule for information regarding those
doors.
Sheet A-112 Comments
The room use has been identified as medical records storage.
Sheet A-117 Comments
The stair barrier is to be located at the Third floor landing to prevent accidental exiting to the
roof level.
Sheet A-119 Comments
The door is a standard hollow metal door and frame. The erroneous callouts in the remarks
column have been erased.
Sheet A-119 Comments
The overhead door is type E.
Sheet A-201 Comments
2
Signage a* barrier has been added to inform the pu*f the 10'-0" height restriction on
vehicles entering the building. A second sign and barrier will be installed at the bottom of the
ramp to alert drivers that the second floor has a maximum clear height of T-O".
End of Non -Structural Comments Response
Please call me @ 206-571-5612 if you have any questions regarding the above responses.
Sincerely,),.
Jim Wieben, DDG Architects
4
I IVT
'ILI 616E
EI
I 'IE
ba.�,.-
LEM .1. 15 M M.
'SEE wu
-
mi%k 0. j pvwii
c
c
11-LI DII-1 10
r,"!"M
rt-t
J\s
F1.11 .0,
NJ
IS22
E-(RGEICI MIJ
v
Ic. .1 FE. I[
"I' 'r.,
I - .1 IWIE
"I IE.0
c
I r" , .,
Ile .,I 1E.-
%0. ID! 11 1111
K e LIILE
It. t
WON
cz3
a
IE
SEE .11
sic TIN c
T-1
TZ
11:11 lt�'
It
T-NE W.
7
va
Pa
P-, \L
—= = mi
TABULATION
NEI oll K.GHI
IE- NEI :w D., .1.01
Isl(Ell 1.10.11.1
la.51 182, 11M,
ull—cowt- 4VW
.1$511 N
KcEss
m wo
MD ------
�nt—uE
8 B B.
HHH
..8 Ei H.
nt
121112 1�051LIUI ��OUI�l ING (STEEL) WIMILIFFLE
F 3 S N 7AFOP555 W/MUrE-rLtR
PU 15JAC405845
It'. - ME
TABULATION
NEI oll K.GHI
IE- NEI :w D., .1.01
Isl(Ell 1.10.11.1
la.51 182, 11M,
ull—cowt- 4VW
.1$511 N
KcEss
m wo
MD ------
�nt—uE
8 B B.
HHH
..8 Ei H.
nt
121112 1�051LIUI ��OUI�l ING (STEEL) WIMILIFFLE
F 3 S N 7AFOP555 W/MUrE-rLtR
PU 15JAC405845
It'. - ME
is
November 16, 2011
City of Edmonds
Leif Bjorback, Assistant Building Official
121 5h Avenue North
Edmonds, WA 98020
RE: Response to Plan Review Comments, dated 10-28-11
Plan Check # 2011-0815
Dear Leif,
Donahou Design Group
This response letter is accompanying copies of the revised building permit drawings submitted for the Premier
Orthopedics Office Building to be located at 21401 72d Ave. W, Edmonds, WA. Based on the plan check comments
noted above, corrections have been made to the drawings originally submitted. All changes to the documents since the
original submittal to the City of Edmonds have been clouded including additional information not associated with City
comment letters. The non-structural responses to your comments are indicated on the drawings as follows:
General Comments
The completed Exterior Envelope Summary forms are attached to this letter.
2. The executed Special Inspections agreement for soils and structural inspections will be
submitted when the Contract has been signed with testing organization. The Special
Inspection form has been added to the list of deferred submittals found on Sheet G-001.
3. Reference details 16 and 17, Sheet A502 for UL rated penetration fire stopping.
Sheet G-001 Comments -7 9
0L_ ILC
Reference Sheet G-00 I and find added General Note No. 27.
Sheet CS Comments
v5� Reference Sheet CS. The line representing the area we have defined as an atrium was
omitted, making the note confusing. The line has been added to the resubmitted documents
and represents the limits of the atrium enclosure.
Sheet A-1 11 Comments
The plan detail callout has been corrected on drawings A-111, A-112 and A-1 13 to read
Details I and 2, Sheet A-1 18.
1,<_ The section references were not used and have been deleted. RESUB
NOV 17 2011
BUILDING DEPARTMENT
OITY OF EDMONDS
16398 NE 85" St Suite 101 Redmond, WA 98052 Tel: (425) 285-9992
8. The parkin*ulation has been updated completely. Teandicap parking count is now
/isted as
1-111 s 6 stalls on the First Floor. Reference the corrected Project Data, Sheet G-001 and
Parking TabI6.
Sheet A-116 Comments
All detail references to Sheet A-504 have been revised to reference the correct detail and sheet
number.
t4K� All detail references to Sheet A-403 have been revised to reference the correct detail and sheet
number.
_4<__ The stair plans and sections found on Sheet A-1 16 have been revised. Among the revisions is
to use a Z!a������ystem for Stair No. 1. The design and detailing of
the stair guardrail and handrail system has been included as a deferred submittal on Sheet G-
001. The plans and section found on Al 16 have been modified to illustrate a 12 inch handrail
extension where the handrail is not continuous. Continuous handrails have been modified to
maintain a continuation of the handrail height between flights of stairs.
vlff— Door No. A303B has been added to the Tenant Improvement documentation. The added door
carries a carries a UL 60 minute rating and will use magnetic hold -opens which will release
"Me opening to trie ele ator hoistway when deactivated by the fire alarm
the door to protect
system. I have indicated the door location on Sheet A-1 13 and A -I 16 with a note directing
you to the Tenant Improvement Documentation.
114� The unspecified opening into the elevator hoistway has been deleted and a CMU enclosure
has been added at Grids A and5 to hold lab samples until they are picked up by a courier.
See the revised drawings A-1 11 and A-1 16.
14. We are seeking to use the exception to IBC 404.5 for smoke control. We interpreted the
design of the atrium to be that of a three story space, but with connection to only two floors
due to the construction of an aluminum and glass smoke partition meeting the requirements of
113C 711.
VA The interior walls adjacent to the "limits of atrium" illustrated on Sheet CS represent the
atrium enclosure, with all walls with at least a I hour assembly rating. The openings in the
atrium enclosure are all protected per table 715.4. The ratings of the specified doors are
found in the Tenant Improvement Permit application documents.
We interpreted the IBC Commentary relative to 404.6 to justify not providing smoke doors at.
the elevator doors in the atrium. We realized we did need to have protection for the opening
on the north wall of elevator(V The tenant improvement plans had planned to provide a rated
enclosure / room at that locati tn but they have decided to provide a rated door at that location
instead. ;s� 1 �
The building is fully sprinklered and served by a monitored fire alarm system. The interior
finishes found in the atrium are Level A and B. The building is equipped with stand-by power
and the exit travel distance is less than the 200 foot limit.
Sheet A-117 Comments
Z,,P� Reference Detail 9, Sheet A-1 17 for the corrected detail callout.
Reference Detail 9, Sheet A -I 17, the incorrect reference to SBC has been revised to read IBC.
47. Reference Building Section C, Sheet A -I 17 and find the added signage regarding the use of
the stair in case of a fire.
Sheet A-118 Comments
,4, �8 Reference Stair Plans I and 2, Sheet A -I 18 and note the revised handrail configuration.
Handrails not continuous from one run of stairs to another within the flight of stairs have been
revised to comply with 10 12.6 and provide a 12 inch extension beyond the last riser.
Sheet A-119 Comments
_Vf9. See Sheet Al 19 for the revised and code compliant SHGC values for the window glazing.
j,_20�.Sece Sheet A -I 19, Door Schedule for the revised verbiage stenciled to the face of the door
reading, "This Door To Remain Unlocked While the Space is Occupied."
Sheet A-130 Comments A - I
Reference the wall types on Sheet A- 115 and A- 130 where the new wall typ N42 D
as been
I _,
created and to Grid I on the plan where the wall type has been added.
A L-7
Sheet A-401 Comments
V'<2.--- The drawing has been updated so that the Wall Sections properly reference details found
elsewhere in the documents.
Sheet A-4022 Comments
1,1'3. The drawing has been updated so that the Wall sections properly reference details found
ewhere in the documents.
4. Reference Wall Sections on Sheets A-401 and A-402 and find the added rigid insulation at the
edge of slab on the third floor of the building. Due to a lack of slab insulation at the north
wall of the building, the Exterior Energy Summary documentation is based on a component
analysis.
End of Non -Structural Comments Response
Please call me @ 206-571-5612 if you have any questions regarding the above responses.
Sincerely,
i Wieben, DDG Architects
. Wiel
OV ED& City of Edmonds
Al
PLAN REVIEW COMMENTS
BUILDING DIVISION
(425) 771-0220
�St. Is"
79
DATE: October,.-26, 2011
TO: Jim Wieben
DDG Architects
Jimw Rc
,,ddgarchitects.com
FROM: Leif 13jorback, Assistant Building Official
RE: Plan Check: 2011-0815
Project: Premier Orthopedic Shell
Project Address: 21401 72'd Ave W
During review of the plans for the above noted project, it was found that the following information,
clarifications or changes are needed. Please provide written responses as to where the changes can
be found on the plans, and submit revised plans/documents to Marie Harrison, Senior Pen -nit
Coordinator. Please cloud or otherwise highlight changes made to the plans whether they are made
in response to this review or those initiated by the owner/design team. Thank you.
The following review comments are non-structural only. Please also respond to the attached
structural review comments from Eagle Eye Consulting.
General
vl 1. Please complete and submit the Exterior Envelope Summary form for the project. This form
may be found on www.neec.net/energy-codes.
Please complete and submit the attached Special Inspection Agreement forms. There is one
each for soils and structural.
3. Provide fire stopping specifications and details for through penetrations of fire rated
assemblies greater than one hour, or list as a deferred submittal.
Sheet G-001
4. Indicate on the plans that a separate permit will be required for demolishing the existing
dumpster enclosure and storage building at the east property line.
Sheet CS
5. It is not clear the extent of what is depicted by the notes "Limits of Atrium." Please clarify.
Sheet A- I 11
6. The detail callouts for stairwells 2 and 3 are not correct. They should refer to sheet A-1 18,
not A- 117. This also occurs on sheets A- 112 and A- 113.
7. Please fill in the references for the detail and section callouts in two locations where "View
Number/Sheet Number" is called out.
0
8. The Accessible Parking table indicates 10 accessible stalls on the first level. Only 6 are
shown on this level. Please clarify.
Sheet A -I 16
9. Please correct the callouts with references to sheet A-504, which is not included in the plan
set; or provide the missing page.
10. Please correct the callout with reference to sheet A-403, which is not included in the plan
set; or provide the missing page.
11. On the stair plans and sections, show top and bottom handrail extensions per E3C 1012.6 at
all stair runs, typical.
12. The north wall of the elevator hoistway looks to be considered the boundary of the atrium.
The opening through this wall at the third floor must be protected by a fire rated door. E3C
404.6 and Table 715.4
13. What is the opening in the north wall of the of the elevator hoistway at level I? Show how
this will be protected to maintain the rating of the atrium wall.
14. Within the atrium, there is connection between all three floor levels as there are no rated
doors in front of the elevators. Is it the intent of the designer to limit the connection to only
two stories in order to avoid requirements for smoke control as per EBC 404.5? Due to the
complexity of the design and related code requirements, please provide a narrative
explaining the rationale of the design of the atrium and associated elements as they relate to
the building code.
Sheet A-1 17
15. Please correct the callout on Detail 9 that references A-404, which is not included in the plan
set; or provide the missing page.
16. The note on Detail 9 indicates the stair treads to comply with requirements of "SBC." Please
change this to "EBC."
17. At the elevator call stations, install a pictorial sign that reads "IN FIRE EMERGENCY, DO
NOT USE ELEVATOR. USE EXIT STAIRS." IIBC 3002.3
Sheet A-1 18
18. On the stair plans and sections, show top and bottom handrail extensions per EBC 1012.6 at
all stair runs, typical.
Sheet A-1 19
19. The window schedule shows the SHGC as 0.45, while the Envelope Summary form shows
0.40, which is the maximum allowed SHGC unless projection factors are provided and
calculations perfonned. WSEC Table 13-1
20. Under Remarks, please change the verbiage of the door sign to read "...unlocked while
space is occupied." 113C 1008.1.9.3
Sheet A-130
2 1. On north wall at roof, where a parapet is required, the parapet must be at least 3 0 inches
above the roof level, and have at least a one hour fire rating. Wall type 'K' which is called
out is not fire rated. IBC 705.11
Sheet A-401
22. Several detail callouts are incomplete.
Sheet A-402
Page 2 of 3
0 0
23. Detail callouts are incomplete.
24. Show R-10 slab perimeter insulation at the heated spaces as per WSEC Table 13-1 and as
indicated on the Envelope Summary.
Page 3 of 3
Eagle Eye Consulting Engineers, P.S.
PO Box 523
01alla, WA 98359
hoytjeter@centurytel.net
206 356-7790
Fax 206 316- 2287
To: CT Engineering
180 Nickerson St. Suite 302
Seattle, WA
Re: Premier Orthopedics
2140172 d Ave West
Edmonds, WA 98026
Plan Review #BLD 2011-0815
Plan review number 01
Task Number 11-05
EECE # EDM 11-05
The above referenced project is in the process of plan review for compliance with
Edmonds ordinances and applicable codes. The following comments,
deficiencies/corrections must be addressed prior to completion of plans review and
subsequent issuance of permits.
Provide revised plans and calculations along with a written response to each of the items
listed below to facilitate a shorter back -check time.
SCOPE OF REVIEW
The scope of this review is for the Structural requirements of this project.
All features were checked only to the extent allowed by the submittals provided. All
portions of this project are assumed to meet or will meet other departmental requirements,
conditions and concerns before permit approval.
Page 2 of 9
Plan Review Number 01
EECE#: EDM 11-05
Premier Orthopedics
2011-0815
STRUCTURAL COMMENTS
General
Please correct the table of contents to reflect the organization of the analysis
submitted. The analysis submitted has the sheets different than the layout of the
table of contents and it was not clear where items required to be designed were
done. Please modify accordingly.
2. All that was in the analysis submitted for the PT slab was the output and not the
input. Please resubmit the complete input and output for the PT slab analysis in
order to complete the review.
3. The design submitted appears not to account for the live load of the lobbies of
100 psf but used a live load of 40 psf. Please clarify upon response. ASCE table
4-1
4. The geotechnical report did not have recommendations for the coefficient of
friction and passive earth pressure as noted in the general note s. Please have the
geotechnical engineer justify the use of a coefficient of friction of .4 and passive
earth pressure of 225 PCIF used in the analysis.
5. The analysis for the vault lid appears not to address any live load for the design
(Sheet M I). Please clarify upon the response.
6. The design analysis sheet M5 is for a concrete beam but it is not clear which
concrete beam this is for. Please clarify upon the response. Please provide a key
for the analysis to cross reference to the drawings.
7. Please add the Wobble coefficient (K) and Curvature coefficient (up) on the
drawings. ACI 18.6.2.3
8. Please specify the stressing sequence on the drawings. ACI 18.13.5.3
9. Engineer of Record (EOR), please provide an analysis for the stud rail used for
this project. ESR 2494
10. Please list that the stud rails shall be a special inspection item. ESR 2494
Sheet A- 111
11. Architect of Record (AOR), please provide sheet A-403
Sheet S 1.0 Structural Notes
Page 3 of 9
Plan Review Number 01
EECE#: EDM 11-05
Premier Orthopedics
2011-0815
12. Please list the Dycore planks used for the vault lid under deferred submittal. The
8" hollow core planks are noted to be designed by other. All that was submitted
in the analysis was a sheet pulled out of Concrete Technology Corporation
catalog but the Dycore panel design shall be submitted as shop drawings as
required per 107.3.4.2
Sheet S 1.0 1 Structural Notes
No comment for this sheet at this time.
Sheet S1.02 Concrete Details
No comments for this sheet at this time.
Sheet S2.00 Pile Plan Foundations Plan
13. EOR, the PC2 along grid 8 has the column not centered on the pile cap. Please
provide an analysis for the pile cap with moment induced by the eccentricity
based off center of mass.
14. EOR, please clarify if there is a steel post bearing on the slab west of grid E on
grid line 8.
15. 1 was unable to find in the analysis the pile cap design shown on this sheet.
Please clarify upon the response.
16. EOR, please modify the foundation notes to show where the sheet SXX and
detail X is located in order to complete the review.
17. EOR, please provide information for the 8" bridge slab noted west of grid A
between grids 3 and 4:
Sheet S2.01 Vault Plans and Sections
18. Sections 17: The design analysis submitted states dowels shall be #5 at. 24" O/C
but the details state #4 at 24" O/C. Please clarify why the analysis states larger
diameter bars dowels size than noted on the drawings.
19. Details 1: EOR, please provide an analysis for the wall pier. I was unable to find
this in the submitted analysis. Based off the drawings, it appears this would be
classified as a column based of horizontal length to thickness is less than 2.5. If
this is the case, the ties are required to go full height for column requirement of
ACI. IBC 1908.1.4
0 0
Page 4 of 9
Plan Review Number 01
EECE#: EDM 11-05
Premier Orthopedics
2011-0815
20. Sections 16 and 17: EOR, please clarify where the vertical reinforcement for the
vault wall is specified. The horizontal is called out and the dowels but I was
unable to determine the typical vertical steel shown in order to check capacity.
Please clarify upon the response.
2 1. EOR, the lobby area shall be designed for a live load of 100 psf but based off
the submitted analysis the live load used was 40 psf.
Sheet S2.02 LI Slab Reinforcement
22. Please add section cuts to show which sections shall be used where. Nothing is
called out at this time.
23. The design output requires #6 top bars at the perimeter but the drawings do not
reflect this. Please modify accordingly. For example, grid lines D and I state
15#6 top but this is not reflected on the drawings.
24. The design analysis output states 20 #6 bats top each way at column locations
C3 between grid I and 2 and grid B. However, the drawing states 18 #6 bars.
Please submit an analysis to justify the smaller amount of steel than required by
analysis.
25. The design analysis plan states 20 #6 bars top required each way at grid 2 G but
the drawings state 18. Please submit an analysis for the smaller amount of
reinforcement bars specified than required by analysis.
26. The design analysis at the stair framing wall state 20 #6 but the drawings do not
reflect this. Please clarify upon the response.
27. Grid 4G requires 24 #6 but the drawings state 20 #6. Please modify accordingly
or justify smaller amount of steel provide than the output shows.
28. The design analysis output shows additional bottom reinforcement required but
the drawings do not reflect this. All that is noted is #6 B at 18" O/C with the
additional bottom noted as shown in output. Please clarify upon the response.
Sheet S2.1 I L2 PT Slab Plan (This level could not be completely checked based off the
analysis submitted)
29. EOR, all that was in the analysis was the output for this level. Please submit the
input data in order to complete the review of level two.
Page 5 of 9
Plan Review Number 01
EECE#: EDM 11-05
Premier Orthopedics
2011-0815
30. EOR, the output was unreadable in order to check the CGS and the number of
banded and distributive tendons shown on this sheet. Please submit this upon
the response.
3 1. EOR, it appears, based off places where I am able to read analysis, that there are
less banded tendons than required by the analysis submitted. For example, 20
strands are required along grid line B but the drawings state 17 to be used. There
are other locations so please resubmit an analysis and modify drawings
accordingly.
32. EOR, the slab thickness varies and it appears the minimum average pre -stress of
125 psi is not met based off the information submitted. Please clarify upon the
response. ACI 18.12.4
33. EOR, the analysis submitted states 26 strands along grid C South of grid 7 but
the drawings state 17. Please clarify upon the response.
34. A minimum of 2 tendons shall pass though each direction at the columns but the
drawings do not reflect this. Please modify accordingly or show how ACI
18.12.7 is met. ACI 18.12.6
35. Please clarify the tendon profile at the opening in the slab for the distributive
directions. The tendons are required to be distributive around the opening and it
is not clear how this will be done based off the submitted documents
36. Along grid line B between grid 5 and grid 6 states 22 tendons but analysis
output states 24 strands required. Please clarify upon response.
37. Please add section cuts to show which sections shall be used where. Nothing is
called out at this time.
Sheet S2.12 L2 Mild Reinforcement Plan
38. EOR, please specify the reinforcement at the comer shown on this sheet.
39. EOR, please add the mild steel requirements around the perimeter and opening
in the middle. Mild steel is required at these locations.
40. Please add section cuts to show which sections shall be used where. Nothing is
called out at this time.
Sheet S2.13 Ramp Plans and Sections
Page 6 of 9
Plan Review Number 01
EECE#: EDM 11-05
Premier Orthopedics
2011-0815
4 1. Detail 10: EOR: please provide an analysis for the connection of the ramp
connection to the PT slab.
42. The ramp reinforcement plan has detail 7/S2.13 but there is not a detail 7 on this
sheet. Please clarify upon the response.
43. Section 3: EOR, please provide an analysis for the concrete dowel in to full
height wall to support the design loads.
Sheet S2.21 L3 PT Slab Plan
44. 1 was unable to read the analysis output for this level. Please resubmit this in
order complete the PT tendon profile.
Sheet S2.22 L3 Mild Reinforcement Plan
45. 1 was unable to read the analysis output for this level. Please resubmit this in
order complete the PT tendon profile.
Sheet S3.00 U Column Plan
No comment for this sheet at this time.
Sheet S4.00 Roof Framing Plan
46. EOR, please clarify where the uplift plan is located in the set as noted under
roof framing notes item 4.
47. EOR, please complete the references noted X/S8.Ox noted between grid 5 and
grid 6 and between grid E and D.
48. EOR, please complete the references noted X/S8.Ox noted between grid 6 and
grid 7 and between grid B and A I.
49. EOR, please complete the references noted X/S8.Ox noted between grid 5 and
grid 6 and between grid B and Al.
50. EOR, please complet e the references noted X/S8.Ox noted between grid 8 and
grid 9.
5 1. EOR, please complete the chiller weight for chiller number I and 2 between
grid D and E. There was not mechanical plan to check this.
52. EOR, please specify the angle frames supports at the mechanical units.
Page 7 of 9
Plan Review Number 01
EECE#: EDM 11-05
Premier Orthopedics
2011-0815
53. EOR, please complete the required RTU unit weights noted as XXX# on the
roof plan.
Sheet S4.01 High Roof Framing Plan
54. EOR, please clarify where the uplift plan is located as noted under roof framing
notes 4.
55. EOR, please provide analysis for the high roof framing. I was unable to find this
in the submitted packages in order to complete the review.
56. EOR, details 20/S801 shows a tube steel column but this tube steel column size
is not noted on the drawings. This also is not specified on the foundations sheet.
Please provide the size and analysis for the column supporting the CIOXI 5.3.
57. EOR, there appears to be no support for the 1-1/2 22 gage B deck. There is a
noted C8 frame at MRI Re : 18/S8.01 but this does not show how this is
supported. Please clarify upon the response in order to complete the review.
58. EOR, please complete the reference cuts noted as X/S8.X in order to complete
the review.
59. EOR, please submit a lateral analysis for the high roof framing. This was not in
the submitted analysis or I was unable to find where this was clearly noted.
60. EOR, please provide an analysis for the out of plane forces for the concrete wall
shown on this sheet. This should include the connections to the wall.
6 1. EOR, there appears not to be any LH joists on this sheet but there is a diagram
that states special loading for LH joist. Please clarify where the LH joist are
located.
Sheet S6.00 Concrete Details
62. Detail 16: This detail has a reference 17/S6.0 but there is not a detail 17 on this
sheet. Please clarify upon the response. I assumed the section should state 19
since this states concrete header but please verify.
Sheet S6.01 Concrete Details
63. 20 Concrete shear wall: Base off the horizontal length to thickness, the jamb
appears to be classified as a column and not wall pier. For example, columns are
required to have closed ties but the elevations do not specify closed ties. Please
modify accordingly and submit an analysis to justify reinforcement or submit an
F-�
L
Page 8 of 9
Plan Review Number 01
EECE4: EDM 11-05
Premier Orthopedics
2011-0815
analysis in compliance. with. wall piers. Note, if classified as wall piers, transfer
reinforcement shall not exceed 6". IBC 1908.1.3
64. Wall sections 10: EOR, please complete the reference noted as X/S noted at the
roof level.
Sheet S6.02 Concrete Details
65. Section 9: EOR, please provide an analysis and specify the required connections
of the Precast element to the edge beam.
66. Sections 9: EOR, please provide an analysis for the edge beam shown on this
sheet.
Sheet S7.00 PT Details
No comment for this sheet at this time.
Sheet S7.01 PT Details
No comment for this sheet at this time.
Sheet S7.02 PT Details
67. EOR, please provide an analysis for each of stud rails details on this sheet.
Sheet S8.0 Steel Details
68. Detail 12: EOR, please clarify where this detail is to be used on the plan in order
to check the connections. I could not find where this was specified.
69. Section 3: EOR, please provide an analysis for the connection of the concrete
wall panel to the structure.
70. EOR, please list the concrete panels as a deferred submittal. This was not in the
analysis nor were any of these panels detailed on the drawings. Also, these were
not list under shop drawings on sheet S 1. 00.
Sheet S8.01 Steel Details
7 1. Section 8: EOR, please provide an analysis for the 400S 162-3 3 mil flat at 48"
O/C to support the design loads.
Page 9 of 9
Plan Review Number 01
EECE#: EDM 11-05
Premier Orthopedics
2011-0815
72. Sections 8: EOR, please provide a torsion analysis for the W 12 beams due to the
loads induced at the bottom flange.
Additional corrections may be required following receipt of corrections and
additional information as requested.
Your plans are being reviewed concurrently with the Building Department, Fire
Department, Zoning Department and Public Works Engineering. Changes,
clarifications or additional corrections may be required subsequent to the Building
Department plan review when comments are received from the other concerned
departments.
Should you have any inquiries regarding this letter, please contact Hoyt Jeter at
(206) 356-7790 between 8:00 a.m. and 5:00 p.m.
UM
Hoyt Jeter, P.E.
President
0 Page I of I
Bjorlback, Leif
From: 13jorback, Leif
Sent: Friday, October 28, 2011 4:07 PM
To: 'Jimw@ddgarchitects.com'
Subject: Premier Orthopedic Clinic
Hi Jim, please find the attached building division comments for your project. Feel free to contact
me if you have any questions.
Regards,
Leif -Bjoi-b-cw�
Assistant Building Official
City of Edmonds
(425) 771-0220
10/28/2011
November 16, 2011
Donahou Design Group
City of Edmonds
Jen Machuga, Associate Plannerr
121 5h Avenue North
Edmonds, WA 98020
RE: Response to Planning Review Comments, dated 11-10-11
Plan Check # BLD 2011 - 0815
Dear Jen,
This response letter is accompanying copies of the revised permit submittal drawings submitted for the Premier
Orthopedics Office Building to be located at 21401 72"d Ave. W, Edmonds, WA. Based on the documents noted
above, corrections have been made to the drawings previously submitted. Changes to the documents since the previous
submittal to the City of Edmonds have been clouded, including additions not associated with comments letters. The
responses to your comments are indicated on the drawings as follows:
1. Height Calculations
a. The height rectangle has been graphically modified to be more easily identified on the site
plan drawing.
b. The height calculation has been modified to reflect an average of the grade elevations at the
two points where the height triangle crosses the south and east property lines. See the revised
height calculation on Sheet A- 10 1 and Sheet G-00 1.
C. Reference the revised height calculations on Sheet A 10 1 and G-00 1.
d. Reference Sheet A201 for the height of the tallest mechanical equipment based on the current
mechanical engineering. See also the revised height calculations on Sheets G-001 and A-101.
2. Setbacks
Reference Sheet A 10 1 for an added plan detail indicating the building setbacks from 72 d
Avenue W. Compliance with City of Edmonds Design Standards Section 21.90.020 is
referenced with regards to the encroachment of the building eave into the 4 foot setback.
Since the Code allows an encroachment of up to 30 inches and our encroachment is less than
10 inches, no changes to the building design have been made.
3. Mechanical Equipment
The Owner understands that the when issued, the Permit will carry a condition regarding
potential remedies to correct the objectionable visibility of the roof top mechanig,4
equipment, if such a condition exists upon completion of the project. RESUB
NOV 17 2011
BUILDING DEPARTMENT
OITY OF EDMONDS
16398 NE 85" St Suite 101 Redmond, WA 98052 Tel: (425) 285-9992
4. Design Review
A concurrent resubmittal of the Design Review documentation for File No. PLN20110063 is
occurring with the resubmittal of this response to the Planning Department comments. An
additional resubmittal will be made, should additional corrections be required as a result of
the concurrent review.
5. Landscaping Estimate
A landscape and irrigation cost estimate has been provided by Pennon Construction to be used
in establishing the Landscaping Maintenance Bond amount.
End of Planning Comments Response
Please call me @ 206-571-5612 if you have any questions regarding the above responses.
Sincerely,
Jim Wieben, DDG Architects
P E N N 0 N
CONSTRUCTION COMPANY. INC.
November 17, 2011
Jim Weiben
Donahou Design Group Architects, LLC
16398 NE 85h Street
Redmond, WA 98052
Re: Landscaping & Irrigation Budget Value
Premier Orthopedics — 21401 72 nd Avenue West; Edmonds, WA
Dear Jim;
In accordance with the request to provide the value of the Landscaping and Irrigation scopes of work for the
Premier Orthopedics project, please review the below table.
Landscape Budget $10,789.. 00
Irrigation Budget $6,165.00
Please review these estimated budgets for your use.
Thank you,
PENNON CONSTRUCTION CO., INC.
41A—���
Mac Sele
NOV 17 2011
BUILDING DEPARTMENT
GENERAL CONTRACTORS OITY OF SOMONDS
5303 1" AVENUE SOUTH, SUITE 100
S 1: ATT 1. E. WA 9 8 10 8
2o6--i 18-0235 FAX 2o6-4 18-0237
0 f E D) A,
0 CITY OF EDMONDS
0+
PLAN REVIEW COMMENTS
ENGINEERING DIVISION
(425) 771-0220
City Website: www.edmondswa.go
DATE: November 16, 2011
TO: Jim Wieben
jimw@ddgarchitects.com
FROM: Jeanie McConnell, Engineering Program Manager
RE: Application #: bld20110815
Project: Premier Orthopedic Group - Shell & Core, Civil Improvements
nd
Project Address: 2140172 Ave W
During review of the above noted application, it was found that the following information,
corrections, or clarifications are needed. Please submit three (3) sets of revised plans/documents
with a written response to each of the items below to Marie Harrison.
City of Edmonds handouts, standard details and development code can be referenced on the City
website.
GENERAL
04 --(g Please provide an itemized engineers cost estimat * e, including units and unit prices, for b oth on -
site and off -site (right-of-way) improvements, including traffic control. The City prefers use of
the King County Site Improvement Bond Quantity Worksheet.
o A bond is required to be placed for all right-of-way improvements. The amount of the bond
will be based on 120% of the City approved estimate for all right-of-way improvements.
The City will inform you of the appropriate bon ' d amount after review of the cost estimate.
Bond forms can be obtained from Marie Harrison, Permit Coordinator - 425-771-0220 or
Harrison(o),ci.edmonds.wa.us
o Inspection fees for this project will be calculated at 2.2% of the 120% City approved
estimate for all improvements.
OV—Provide a Construction Sequence within the plan set similar to the example provided on our
website: http://www.edmoiidswa.gov/services/Teniiits-developmeiit/handouts-
foi-ms/enginecring-standards.btniI
Where standard details are referenced throughout the plans, please also reference the civil plan
sheet number in which it is located.
In past discussions with Community Transit, the City Traffic Engineer had beeninformed that
the bus stop in front of the subject development will be removed. The timing of this is unclear
and we ask that you please coordinate directly with CT. It may not be necessary to add a
concrete b s pad at this locati9n, etc
#fFQW tc (MS ��
W20110815-Premier-Ortho-E Ldoc Page] of6
64/Compaction test reports will be required for'all utility trenches within the City right-of-way.
Subgrade shall be compacted to 95% and copies of test reports provided to the City prior to
paving. Please add notes to the plans reflecting such.
STORM DRAINAGE REPORT
The following comments are provid6e-d �by'jerry Shuster, Stormwater Engineer Program Manager, in
11,
review of the Final Engineerin Report (Drainage Calculations) dated September 2011 and
, g,
041 prepared by Robert Long ofLSA. Specific questions regarding these comments should be directed
to Jerry by email at sbuster(cDci.edmonds.Wa.us or by phone at 425.771.0220.
1 . Page E-3 — Th6 outlet structure is modeled as a notched rectangular weir with a notch height of
zero. Chna g t flat weir (no notch).
2. Page 6 the Geotechnical Report, Appendix H, recommends the vault be designed to withstand
buoy t forces associated with groundwater levels that rise to within 2 feet of the surface. Such
u
ca. u ations are not included. Please provide.
3. /eginning on page A- 1, change page footer from O'Reilly Auto Parts to Premier Orthopedic
1
G roup I
roup and please correct the address as well.
A-101 — SITE PLAN
&4V,,Site plan should be revised to show conditions of site post construction. Frontage
improvements will include a 4-foot wide landscape buffer between the street and the 5-foot
wide sidewalk.
01— Please remove notes pertaining to construction of frontage improvements (painting curb,
dimensions of parking and service entry and curb removal).
Please add a note that references the civil construction plans for engineering requirements.
A-111 — FIRST FLOOR PLAN
I . The property frontage along 72 d Ave W is shown on this plan, but is not accurate with the
proliosed design. Please revise as required to accurately show sidewalk and landscape strip.
2. Detail 2 on Sheet A-102 is referenced along sections of the city sidewalk. Please revise this plan
sheet so that requirements for construction of right-of-way improvements are not shown and the
civil construction plans are referenced instead.
3. Detail 5 is referenced as a typical detail for construction of curb. Vertical curb can be installed
on private plan, but plans shall clearly indicate this.
L-1.0 — LANDSCAPE PLAN
Please show location of irrigation ' meter and required DCVA.
Add a note to the plans stating: A separate irrigation permit must be obtained from the 6ty
Public Works Department. Prior to final acceptance provide the City Cross -Connection Control
Specialist with a copy of the backflow test report. Test reports can be faxed to 425.744.6057 or
e-mailed to mcmujpby(a_)ci.edmonds.wa.us Backflow testing will be required on an annual basis
thereafter.
Please note that the irrigation system shall be located entirely on private property.
bid2011O8l5-Premier—Ortho-El.doc Page 2 of 6
0 0
SHEET C1 — SITE DEVELOPMENT, DRAINAGE AND UTILITY PLAN
Please move the drainage and utility information to a separate sheet. It is really difficult to see
some of the improvements -along the frontage with thi's much information on one plan sheet.
For clarity, existing features that are "to be removed" could be shown on the grading and
erosion control plan.
Add Utility Purveyor information to the site development plan.
Ot_4n the NOTES section, please add:
a. A separate right-of-way construction permit is required for all work within the City
right-of-way. A ROW permit application with contractors signature shall be provided to
th
the City, Please note, an application was given to Jeff Still of Pennon on November 14
Please revise the Sheet Index to include the Traffic Control Plan.
0--l'At each catch basin, callout all inlets/outlets and specify diameter of pipe.
JV.,The storm main extension proposed in 72 nd Ave W at the south end of the project shall be 12".
Please revise plans accordingly.
0%"At the south end of the project, please revise plans to note removal of the existing catch basin
AND the storm run that tees into the storm main running east/west. The note should indicate
removal of the storm line is required unless otherwise directed by the City inspector. With this
note, field changes could be made to address feasibility -issues once the actual location of the
storm line is known.
OJ2. Revise CB#3 to state the CB is to be installed in the flow line at the east/west crossing (not at
the pipe tee location).
60"t the north end of the project at the existing CB in 72 nd Ave, plans indicate "remove CB and
plug pipe". Please include additional notes that state the pipe can be plugged and abandoned in
place IF the existing storm crossing is TV'd prior to abandoning the basin and after the electric,
gas and cable borings are complete. If the construction sequence cannot happen in this order
Al. then the pipe shall be removed and plugged at the main.
Please clarify what the CB#5 area drain is in the trash access drive. Is it a concrete basin? Is it
driveway rated? Additional info/detail would be great.
Olt does not appear as though footing drains and their connection to the storm system is shown on
the plans. Please note that footing drains shall bypass the detention system. Please revise plans
accordingly.
L/tv it appears as though the roof drain tightline near the SW comer of the building could be
configured such that the runs of pipe fro ' in the north and south could connect directly into CB
#1. This change could allow for better maintenance of the system and cleaner construction.
OW-rhe 6" sewer lateral connection to the City main shall be with a wye instead of a tee. This is
due in part to the proximity of this connection to the dead end of the main.
� 6" cleanout with 12" locking Cl lamphole cover shall be located at the property line.
Locating the cleanout on the private property side, in the landscaping, would be acceptable.
The cleanout on the exterior of the building could be eliminated if the owner would like to rely
on an interior building cleanout instead.
�'ease note the invert elevation of the sewer pipe at the building and at the main.
Plans indicate a separate water meter and tap off the domestic feed for the irrigation system. If
pr f r c is to v
the e e en e ha e the irrigation system billed separately from the domestic water then a
separate tap off the main will be required. Please note, sewer charges are based off of domestic
water consumption, so having a separate irrigation meter could reduce the sewer charges for the
site. The City doesn't offer a deduct method for this.
0 .
foidd io W ~0
W20110815-Premier—Ortho-E Ldoc Page 3 of6
kFor water services 2" and less, the City will perform the tap on the main. The contractor will be
responsible for trenching, backfill and restoration so coordination of this work is critical. 'Please
add notes to the plans to reflect this. Public Works Water Division phone number is
425.771.0235.
___�.22. On the domestic water service, immediately after the meter on private property, an RPBA in
i&� hotbox shall be installed. Please reference and incorporate into the plan set standard detail
A 1\
E7.1 1.
64,Please also reference and incorporate standard detail E7.6.1 for the 2" water meter & box.
*/The water meters shall be located within the City right-of-way. The water meters could be
V located within the 4-foot wide landscape strip between the sidewalk and the street with the
backflow assemblies on private property. Please revise plans accordingly.
(gThe City will not permit a wet tap for the 6" fire line connection to the City main. Two in -line
valves shall be installed on the City water main to either side of the 6" fire line connection.
Please reference and incorporate city standard detail E7.18.1. Please also add parts call outs to
the plans for size of valves, fittings, etc.
The City has specific policy and procedures to be followed for water outages. Please add notes
that require coordination with the City six weeks in advance of shut down. The contractor will
be required to notify businesses of shut down 4 weeks in advance. Policy and sample water shut
off notice can be found on the City website at: http://www.edmondswa.gov/services/�erinits-
development[handouts-forms/enizineering-standards.btrnI
Standard detail E7.19 is referenced on the plans and should be followed for the installation of
the PIV and FDC, however, the connection at the water main should be per standard detail
E7.18. I. Please incorporate detail E7.19 into the plan set and include additional notes as
required.
Please add frontage improvement notes to the plans to provide direction on removal of existing
sidewalk, curb & gutter and replacement with new to City standard details - E2.8 and E2.13.
The standard details are referenced sheet C3, so maybe revising the note "see typical road
section on sheet CY to include something about frontage improvements would address this.
00-Please confirm that construction of the main driveway approach to City standards, versus
WSDOT standards, is the preference of the owner. It would be the preference of the City to
have the approach constructed to WSDOT standards and the sidewalk held at a constant grade
throughout the property frontage.
0A_ t the curb & gutter connection on the north end of the project, please also note that
coordination with City inspector ahead of setting forms is necessary as design field adjustments
may be required.
33. The new curb ramp on the south end of the project should stay in alignment with sidewalk to the
�J ,,Iy north. Please reference and incorporate WSDOT standard detail F-40.16-01 for single direction
V curb ramps. This detail also shows the landscape buffer.
NXurb & gutter shall be removed and replaced in area of stonn main extension on the south end
of the project. If this can be done without damaging the existing sidewalk then sidewalk
replacement will not be required. If the sidewalk is damaged or if conditions are such that
pouring a new curb against the sidewalk isn't feasible, then sections of sidewalk may need to be
replaced.
lUdditional pavement patch will be required due to storm work, curb and gutter replacement and
installation of the curb ramp. Please add notes to the plans reflecting this.
$#-Removal of the curb ramp on the south side of the driveway (McDonalds entrance) and
replacement to meet ADA standards -makes sense at this time. The curb and gutter will need to
W20110815-Premier—Ortho-E Ldoc Page 4 of 6
I
be removed and replaced due to the storm installation and the entrance to this driveway will
need to be repaved and possibly graded some due to the installation of the curb ramp on the
north side of the drive. If the ramp is damaged during construction then replacement to ADA
standards will be required anyways. Please consider incorporating this change into the plan set.
64,On the east side of the building there is a note that indicates removal of existing curbing and
pavement. Please reference Site Plan A- 10 1 and Landscape Plan L- 1.0 for restoration
requirements.
SHEET C2 — GRADING AND EROSION CONTROL (SWPPP) PLAN
Ob Please move TESC general.notes from sheet C4 to this sheet.
The SWPPP Legend provides reference to BMP #'s that I don't recognize. Please reference
City standard details.
&-"lease indicate on this'plan sheet where materials and equipment will be staged during
construction.
SHEET C3 — ROAD SECTION AND PROFILE
Please revise the 72 nd Avenue Profile to show 12" PVC storm pipe being installed in the right-
of-way. It appears as though achieving 2-feet of cover over the pipe will not be an issue,
however if it is determined that pipe cover will be less than 2-feet then ductile iron pipe will be
required.
Please revise note for CB#3 to state the new CB will be installed in the flow line to intersect the
existing east/west crossing versus. at pipe tee location.
Revise Frontage Improvement Section A -A to show asphalt depth as match existing with a
minimum depth of 2". In areas of trench work or where the subgrade is to be rebuilt, detail E2.3
as shown on sheet C5, shall be followed.
lilwfAlc I" I K�
SHEET C4 — NOTES AND DETAMS CA is KM -9X
Please revise General Note #26 to also state that the City has specific policy and iO rels #o
be followed for water outages. Coordination with the City is required six weeks in advance of
shut down. The contractor will be required to notify businesses of shut down 4 weeks in
ty website at:
advance. Policy and sample water shut off notice can be found on the Ci
hltp://w�vw.edmondswa.gov/services/Termits-development/handouts-forms/engineeriniz� Ajew
standards.html
Note in the Detention Vault Section Detail that access manholes shall have solid lids. 4#t
Restrictortatch Basin #1 Detail indicates installation of a removable plug. A removable plug
should not be provided unless a shear gate with lift handle will be installed. If there is another
reason for the removable plug, please provide a response indicating such.
SHEET C5 — NOTES AND DETAILS
Oy. Detail E2.27.2 — Multi-family/Commercial Entrance - If the decision is made to not construct
this style of entrance, please remove it from the plan set. If this style of entrance is constructed,
please note that truncated domes will not be required.
W20110815-Premier—Ortho-E Ldoc Page 5 of 6
6PDetail E'2.15 — Curb Ramp Type 2 — Please replace this curb ramp with WSDOT standard detail
F-40.16-01. Please note, truncated domes will be required at this location.
,-SHEET 1 of 1 — TRAFFIC CONTROL PLAN
I . Please provide separate traffic control plans for the various phases of construction to address
utility tie-in's, frontage improvements, concrete pours on site, materials delivery, etc.
2. Where lane shifts are proposed, please show the full spectrum of 72 nd Ave W to ensure I 0-foot
minimum lane widths will be maintained.
3. Placement of cones, spacing, taper, etc. shall be included.
4. Sidewalk closure signage shall be provided as appropriate.
5. Coordination with Community Transit will be required for temp or permanent bus stop
relocation.
6. Parking and sidewalk closures in excess of 72-hours shall be app roved by the City and
disruption fees will apply. Please clearly state your intent and provide a request in writing for
such closure.
�q
Please contact me at 425-771-0220 or by e-mail at mcconnell(a-),ci.edmonds.wa.us if you have
specific questions regarding these plan corrections.
M20110815-Premier—Ortho-E Ldoc Page 6 of 6
Message Page I of 2
McConnell, Jeanie
From: McConnell, Jeanie
Sent: Wednesday, November 16, 20112:28 PM
To: 'jimw@ddgarchitects.com'
Cc: 'Scott Shanks'; Harrison, Marie
Subject: Premier Ortho, bld20110815 - Engineering Comments
Jim,
Please find attached plan review comments from the Engineering Division in review of the Shell
& Core and Civil plans for Premier Orthopedic.
Please let me know if you have any questions.
Regards,
Jeanie
JEANIE McCONNELL I Engineering Program Manager I mcconnellfti.edmonds.wa.us
Public Works Department I Engineering Division 1 121 5th Ave N I Edmonds, WA 98020
City of Edmonds I www.edmondswa.gov I Tel: 42S.771.0220 I Fax: 425.771.0221
----- Original Message -----
From: Harrison, Marie
Sent: Wednesday, November 16, 20112:00 PM
To: McConnell, Jeanie
Subject: FW: Premier Orotho, blc120110815
Hi Jeanie: Would you please see to it that Jim Wieben gets an emailed copy of your
comments? Thanks much.
Marie
From: Jim [mailto:jimw@ddgarchitects.com]
Sent: Wednesday, November 16, 2011 1:27 PM
To: Harrison, Marie
Cc: Scott Shanks; joed@ddgarchitects.com
Subject: RE: Premier Orotho, bld20110815
Hi Marie,
I will be bringing in the response letter for the architectural, and structural. I believe the Tenant
Improvement information will be coming in also, again with its own response letter. I anticipate
11/16/2011
Message Page 2 of 2
0
that we will be there to make the resubmittal at 2:30pm tomorrow afternoon. We will also be
resubmitting the ARB review documents with a separate response letter for that application process.
Is there a way to make sure that we are sent (email) the engineering comments as soon as they are
ready? I would like to know that there are no cross -over comments that I need to include in my
architectural resubmittal. Thanks for the help and let me know if you are already committed at 2:30
tomorrow.
Jim Wieben
From: Harrison, Marie [mailto:Harrison@ci.edmonds.wa.usI
Sent: Wednesday, November 16, 2011 12:16 PM
To: JIMW@DDGARCHrTECTS.COM
Subject: Premier Orotho, bld20110815
Hello Jim: Linda Thomquist told me you are anxious to resubmit for Premier Ortho. I spoke with Jeanie
McConnell in our engineering department and she should have comments completed today. I am okay
with you resubmitting the architectural and structural in advance. I would like to try and get them shipped
to the consultant prior to the holidays. Please be sure to submit a response letter along with the affected
sheets. Please let me know if you have any questions.
Sincerely,
Marie Harrison, CPT I Senior Permit Coordinator
City of Edmonds
121 5th Avenue N Edmonds WA 98020
9 425.771.0220 ext. 1389
APlease consider the environment before printing this e-mail
11/16/2011
OV E D'v
CITY OF EDMONDS
PLAN REVIEW COMMENTS
ENGINEERING DIVISION
St. ISP (425) 771-0220
City Website: www.edmondswa.go
DATE: November 16, 2011
TO: Jim Wieben
jimw@ddgarchitects.com
FROM: Jeanie McConnell, Engineering Program Manager
RE: Application #: bld20110815
Project: Premier Orthopedic Group — Shell & Core, Civil Improvements
Project Address: 2140172 "d Ave W
During review of the above noted application, it was found that the following information,
corrections, or clarifications are needed. Please submit three (3) sets of revised plans/documents
with a written response to each of the items below to Marie Harrison.
City of Edmonds handouts, standard details and development code can be referenced on the City
website.
GENERAL
Please provide an itemized engineers cost estimate, including units and unit prices, for both on -
site and off -site (right-of-way) improvements, including traffic control. The City prefers use of
the King County Site Improvement Bond Quantity Worksheet.
o A bond is required to be placed for all right-of-way improvements. The amount of the bond
will be based on 120% of the City approved estimate for all right-of-way improvements.
The City will inform you of the appropriate bond amount after review of the cost estimate.
Bond forms can be obtained from Marie Harrison, Permit Coordinator — 425-771-0220 or
Harrison@ci.edmonds.wa.us
o Inspection fees for this project will be calculated at 2.2% of the 120% City approved
estimate for all improvements.
2. Provide a Construction Sequence within the plan set similar to the example provided on our
website: http://www.edmondswa.gov/services/permits-development/handouts-
forms/engineering-standards.htmI
3. Where standard details are referenced throughout the plans, please also reference the civil plan
sheet number in which it is located.
4. In past discussions with Community Transit, the City Traffic Engineer had been informed that
the bus stop in front of the subject development will be removed. The timing of this is unclear
and we ask that you please coordinate directly with CT. It may not be necessary to add a
concrete bus pad at this location, etc.
bid2011O8l5-Premier—Ortho-El.doc Page I of 6
5. Compaction test reports will be required for all utility trenches within the City right-of-way.
Subgrade shall be compacted to 95% and copies of test reports provided to the City prior to
paving. Please add notes to the plans reflecting such.
STORM DRAINAGE REPORT
The following comments are provided by Jerry Shuster, Stormwater Engineer Program Manager, in
review of the Final Engineering Report (Drainage Calculations) dated September 2011 and prepared
by Robert Long of LSA. Specific questions regarding these comments should be directed to Jerry
by email at shuster@ci.edmonds.wa.us or by phone at 425.771.0220.
I . Page E-3 — The outlet structure is modeled as a notched rectangular weir with a notch height of
zero. Change to a flat weir (no notch).
2. Page 6 of the Geotechnical Report, Appendix H, recommends the vault be designed to withstand
buoyant forces associated with groundwater levels that rise to within 2 feet of the surface. Such
calculations are not included. Please provide.
3. Beginning on page A- 1, change page footer from O'Reilly Auto Parts to Premier Orthopedic
Group and please correct the address as well.
A-101 — SITE PLAN
1 . Site plan should be revised to show conditions of site post construction. Frontage improvements
will include a 4-foot wide landscape buffer between the street and the 5-foot wide sidewalk.
2. Please remove notes pertaining to construction of frontage improvements (painting curb,
dimensions of parking and service entry and curb removal).
3. Please add a note that references the civil construction plans for engineering requirements.
A-111 — FIRST FLOOR PLAN
I . The property frontage along 72 "d Ave W is shown on this plan, but is not accurate with the
proposed design. Please revise as required to accurately show sidewalk and landscape strip.
2. Detail 2 on Sheet A-102 is referenced along sections of the city sidewalk. Please revise this plan
sheet so that requirements for construction of right-of-way improvements are not shown and the
civil construction plans are referenced instead.
3. Detail 5 is referenced as a typical detail for construction of curb. Vertical curb can be installed
on private plan, but plans shall clearly indicate this.
L-1.0 — LANDSCAPE PLAN
I . Please show location of irrigation meter and required DCVA.
2. Add a note to the plans stating: A separate irrigation permit must be obtained from the City
Public Works Department. Prior to final acceptance provide the City Cross -Connection Control
Specialist with a copy of the backflow test report. Test reports can be faxed to 425.744.6057 or
e-mailed to mcmulphykci.edmonds.wa.us Backflow testing will be required on an annual basis
thereafter.
3. Please note that the irrigation system shall be located entirely on private property.
W20110815-Premier—Ortho-E Ldoc Page 2 of 6
SHEET C1 — SITE DEVELOPMENT, DRAINAGE AND UTILITY PLAN
4. Please move the drainage and utility information to a separate sheet. It is really difficult to see
some of the improvements along the frontage with this much information on one plan sheet.
5. For clarity, existing features that are "to be removed" could be shown on the grading and erosion
control plan.
6. Add Utility Purveyor information to the site development plan.
7. In the NOTES section, please add:
a. A separate right-of-way construction permit is required for all work within the City right-
of-way. A ROW permit application with contractors signature shall be provided to the
th
City. Please note, an application was given to Jeff Still of Pennon on November 14
8. Please revise the Sheet Index to include the Traffic Control Plan.
9. At each catch basin, callout all inlets/outlets and specify diameter of pipe.
10. The storm main extension proposed in 72 d Ave W at the south end of the project shall be 12".
Please revise plans accordingly.
11. At the south end of the project, please revise plans to note removal of the existing catch basin
AND the storm run that tees into the storm main running east/west. The note should indicate
removal of the storm line is required unless otherwise directed by the City inspector. With this
note, field changes could be made to address feasibility issues once the actual location of the
storm line is known.
12. Revise CB#3 to state the CB is to be installed in the flow line at the east/west crossing (not at
the pipe tee location).
13. At the north end of the project at the existing CB in 72 nd Ave, plans indicate "remove CB and
plug pipe". Please include additional notes that state the pipe can be plugged and abandoned in
place IF the existing storm crossing is TV'd prior to abandoning the basin and after the electric,
gas and cable borings are complete. If the construction sequence cannot happen in this order
then the pipe shall be removed and plugged at the main.
14. Please clarify what the CB#5 area drain is in the trash access drive. Is it a concrete basin? Is it
driveway rated? Additional info/detail would be great.
15. It does not appear as though footing drains and their connection to the storm system is shown on
the plans. Please note that footing drains shall bypass the detention system. Please revise plans
accordingly.
16. It appears as though the roof drain tightline near the SW comer of the building could be
configured such that the runs of pipe from the north and south could connect directly into CB
#1. This change could allow for better maintenance of the system and cleaner construction.
17. The 6" sewer lateral connection to the City main shall be with a Wye instead of a tee. This is
due in part to the proximity of this connection to the dead end of the main.
18. A 6" cleanout with 12" locking CI lamphole cover shall be located at the property line. Locating
the cleanout on the private property side, in the landscaping, would be acceptable. The cleanout
on the exterior of the building could be eliminated if the owner would like to rely on an interior
building cleanout instead.
19. Please note the invert elevation of the sewer pipe at the building and at the main.
20. Plans indicate a separate water meter and tap off the domestic feed for the irrigation system. If
the preference is to have the irrigation system billed separately from the domestic water then a
separate tap off the main will be required. Please note, sewer charges are based off of domestic
water consumption, so having a separate irrigation meter could reduce the sewer charges for the
site. The City doesn't offer a deduct method for this.
M20110815-Premier—Ortho-E Ldoc
Page 3 of 6
I
0 0
21. For water services 2" and less, the City will perform the tap on the main. The contractor will be
responsible for trenching, backfill and restoration so coordination of this work is critical. Please
add notes to the plans to reflect this. Public Works Water Division phone number is
425.771.0235.
22. On the domestic water service, immediately after the meter on private property, an RPBA in
hotbox shall be installed. Please reference and incorporate into the plan set standard detail
E7.1 1.
23. Please also reference and incorporate standard detail E7.6.1 for the 2" water meter & box.
24. The water meters shall be located within the City right-of-way. The water meters could be
located within the 4-foot wide landscape strip between the sidewalk and the street with the
backflow assemblies on private property. Please revise plans accordingly.
25. The City will not permit a wet tap for the 6" fire line connection to the City main. Two in -line
valves shall be installed on the City water main to either side of the 6" fire line connection.
Please reference and incorporate city standard detail E7.18. 1. Please also add parts call outs to
the plans for size of valves, fittings, etc.
26. The City has specific policy and procedures to be followed for water outages. Please add notes
that require coordination with the City six weeks in advance of shut down. The contractor will
be required to notify businesses of shut down 4 weeks in advance. Policy and sample water shut
off notice can be found on the City website at: http://www.edmondswa.gov/services/i)ennits-
development/handouts-forms/engineering-standards.htmI
27. Standard detail E7.19 is referenced on the plans and should be followed for the installation of
the PIV and FDC, however, the connection at the water main should be per standard detail
E7.18.1. Please incorporate detail E7.19 into the plan set and include additional notes as
required.
28. Please add frontage improvement notes to the plans to provide direction on removal of existing
sidewalk, curb & gutter and replacement with new to City standard details — E2.8 and E2.13.
The standard details are referenced sheet C3, so maybe revising the note "see typical road
section on sheet CY' to include something about frontage improvements would address this.
29. Please confirm that construction of the main driveway approach to City standards, versus
WSDOT standards, is the preference of the owner. It would be the preference of the City to
have the approach constructed to WSDOT standards and the sidewalk held at a constant grade
throughout the property frontage.
30. At the curb & gutter connection on the north end of the project, please also note that
coordination with City inspector ahead of setting forms is necessary as design field adjustments
may be required.
3 1. The new curb ramp on the south end of the project should stay in alignment with sidewalk to the
north. Please reference and incorporate WSDOT standard detail F-40.16-01 for single direction
curb ramps. This detail also shows the landscape buffer.
32. Curb & gutter shall be removed and replaced in area of storm main extension on the south end
of the project. If this can be done without damaging the existing sidewalk then sidewalk
replacement will not be required. If the sidewalk is damaged or if conditions are such that
pouring a new curb against the sidewalk isn't feasible, then sections of sidewalk may need to be
replaced.
33. Additional pavement patch will be required due to storm work, curb and gutter replacement and
installation of the curb ramp. Please add notes to the plans reflecting this.
34. Removal of the curb ramp on the south side of the driveway (McDonalds entrance) and
replacement to meet ADA standards makes sense at this time. The curb and gutter will need to
bld2011O8l5-Premier—Ortho-El.doc Page 4 of 6
be removed and replaced due to the storm installation and the entrance to this driveway will
need to be repaved and possibly graded some due to the installation of the curb ramp on the
north side of the drive. If the ramp is damaged during construction then replacement to ADA
standards will be required anyways. Please consider incorporating this change into the plan set.
35. On the east side of the building there is a note that indicates removal of existing curbing and
pavement. Please reference Site Plan A- 10 1 and Landscape Plan L- 1.0 for restoration
requirements.
SHEET C2 — GRADING AND EROSION CONTROL (SWPPP) PLAN
1. Please move TESC general notes from sheet C4 to this sheet.
2. The SWPPP Legend provides reference to BMP Ws that I don't recognize. Please reference City
standard details.
3. Please indicate on this plan sheet where materials and equipment will be staged during
construction.
SHEET C3 — ROAD SECTION AND PROFILE
I . Please revise the 72 d Avenue Profile to show 12" PVC storm pipe being installed in the right-
of-way. It appears as though achieving 2-feet of cover over the pipe will not be an issue,
however if it is determined that pipe cover will be less than 2-feet then ductile iron pipe will be
required.
2. Please revise note for CB#3 to state the new CB will be installed in the flow line to intersect the
existing east/west crossing versus at pipe tee location.
3. Revise Frontage Improvement Section A -A to show asphalt depth as match existing with a
minimum depth of 2". In areas of trench work or where the subgrade is to be rebuilt, detail E2.3
as shown on sheet C5, shall be followed.
SHEET C4 — NOTES AND DETAILS
1 . Please revise General Note #26 to also state that the City has specific policy and procedures to
be followed for water outages. Coordination with the City is required six weeks in advance of
shut down. The contractor will be required to notify businesses of shut down 4 weeks in
advance. Policy and sample water shut off notice can be found on the City website at:
http://www.edmondswa.gov/ser-vices/�)ermits-development/handouts-forms/engineering-
standards.html
2. Note in the Detention Vault Section Detail that access manholes shall have solid lids.
3. Restrictor/Catch Basin #1 Detail indicates installation of a removable plug. A removable plug
should not be provided unless a shear gate with lift handle will be installed. If there is another
reason for the removable plug, please provide a response indicating such.
SHEET C5 — NOTES AND DETAILS
1. Detail E2.27.2 — Multi-family/Commercial Entrance - If the decision is made to not construct
this style of entrance, please remove it from the plan set. If this style of entrance is constructed,
please note that truncated domes will not be required.
W20110815-Premier—Ortho-E Ldoc
Page 5 of 6
0
2. Detail E2.15 — Curb Ramp Type 2 — Please replace this curb ramp with WSDOT standard detail
F-40.16-01. Please note, truncated domes will be required at this location.
SHEET I of 1 — TRAFFIC CONTROL PLAN
I . Please provide separate traffic control plans for the various phases of construction to address
utility tie-in's, frontage improvements, concrete pours on site, materials delivery, etc.
2. Where lane shifts are proposed, please show the full spectrum of 72"d Ave W to ensure 10-foot
minimum lane widths will be maintained.
3. Placement of cones, spacing, taper, etc. shall be included.
4. Sidewalk closure signage shall be provided as appropriate.
5. Coordination with Community Transit will be required for temp or permanent bus stop
relocation.
6. Parking and sidewalk closures in excess of 72-hours shall be approved by the City and
disruption fees will apply. Please clearly state your intent and provide a request in writing for
such closure.
Please contact me at 425-771-0220 or by e-mail at mcconnell(d),ci.edmonds.wa.us if you have
specific questions regarding these plan corrections.
W20110815-Premier—Ortho-E Ldoc Page 6 of 6
Machuga,Jen
From: Machuga,Jen
Sent: Thursday, November 10, 2011 2:37 PM
To: 'jimw@ddgarchitects.com'
Cc: 'Scott Shanks'
Subject: Plan Review Comments for Premier Orthopedic Group (BLD20110815 and BLD20110816)
Hi Jim,
The Planning Di vision's comments on the building permit applications for the Premier Orthopedic Group building and
tenant improvement (BLD20110815 and BLD20110816) are attached. I am also attaching the design review comments
referenced in my letter. Please feel free to contact me if you have any questions.
Sincerely,
Jen
11-0815 and ADB-11-63 Request
1-0816 Review I.p., for Addition...
Jennifer Machuga, Associate Planner
City of Edmonds, Planning Division
121 - 5th Avenue North
Edmonds, WA 98020
(425) 771-0220 ext. 1224
Machuga@ci.edmonds.wa.us
0 0
CITY OF EDMONDS - 1215'h AVENUE NORTH - EDMONDS, WA 98020
PHONE: 425.771.0220 - FAx: 42.5.771.0221 - WEB: www.ci.edmonds.wa.us
DEVELOPMENT SERVICES DEPARTMENT: PLANNING - ENGINEER1NG - BUILDING
November 10, 2011
Mr. Jim Wieben
DDG Architects
Email: j imw@ddgarchitects.com
RE: PLAN REVIEW COMMENTS FOR PLAN CHECKS BLD20110815 & BLD20110816
PREMIER ORTHOPEDIC GROUP, LOCATED AT 21401 — 72 ND AVE. W
Dear Mr. Wieben:
I have reviewed the above building permit applications for the Planning Division, and it was found
that the following information, corrections, or clarifications will need to be addressed before review
can continue:
1. Height Calculations: Please respond to the following items regarding the height calculations:
a. Change the style of the height rectangle as shown on the site plan (A-101) in order to avoid
confusion with the other line styles utilized for the building outlines. A dashed or dotted
line utilized for the height rectangle would be easier to distinguish from the other line styles
utilized for the building.
b. Correct the location of the height rectangle to reflect the definition of height contained
within ECDC 21.40.030 which states, "average level shall be determined by averaging
elevations of the downward projections of the four comers of the smallest rectangle which
will enclose all of the building, excluding a maximum of 30 inches of eaves. If a comer
falls off the site, its elevation shall be the average elevation of the two points projected
downward where the two sides of the rectangle cross the property line." As such, the
height rectangle needs to be revised to show where the southeastern comer of the height
rectangle falls off site. Additionally, the elevation of the southeastern comer of the height
rectangle must be based on the average of the two points where the rectangle crosses the
property lines.
c. Update the average grade and maximum allowed height based on the revised elevation of
the southeastern comer of the height rectangle as discussed above. When updating the
height calculations, note that the elevations of the average grade and maximum allowed
height cannot be rounded up.
d. The elevation of the proposed building height was provided on the plans, but please also
include the elevation of the highest point of the mechanical equipment.
2. Setbacks: The CG2 zone requires a minimum four -foot street setback. Although the plans
indicate that the face of the main entrance to the building will be a minimum of four feet from
the western property line, several of the plan sheets (including A- 10 1, A- 116, A- 13 0, and
A-301) indicate that the gold decorative strip on the wall of windows as well as the building
overhang, particularly over the main entrance, project into the minimum required four -foot
setback area. Unfortunately, there are no exceptions in the General Commercial site
development standards for any portions of the structure to project into the four -foot street
setback. Additionally, the PUD vault located at the northwestern comer of the site cannot be
located within the street setback unless it is less than three feet in height. Please revise the .
plans to indicate that all portions of the structure as well as the PUD vault will comply with the
minimum required four -foot street setback.
0
3. Mechanical Equipmen : Documentation has been provided as part of the associated design
review application showing that the mechanical equipment is not anticipated to be visible from
street view. Please note that the permit will be conditioned such that if the mechanical
equipment is visible from street view, it will need to be painted to match the building or
otherwise screened in a manner acceptable to the Planning Division.
4. Design Review: Design review for the subject proposal is being conducted concurrently with
the building permit applications under File No. PLN20110063. Comments regarding the
design review application were sent to Scott Shanks and Dale Pinney on November 9, 2011
(see enclosed). Please note that following response to these items and following design review
approval, the building permit application plans, including the landscaping plan, may need to be
revised to reflect the plans approved through the design review process as well as any
conditions of design review approval.
Landscaping Estimate: Several comments related to the landscape plan were included in the
enclosed letter regarding the design review application. Once the requested changes have been
made to the landscape plan, please provide a cost estimate for all labor and materials for
installation of the landscaping. This estimate will be utilized for calculation of the required
landscape maintenance bond. The maintenance bond itself, however, does not need to be
submitted until the landscaping has been installed. The maintenance bond will be requested at.
the time of the Planning Division's inspection of the project.
All submittals should be made to a Development Services Permit Coordinator, Monday through
Friday, between 8:00 am and 4:30 pm. If you have any questions, feel free to contact me at (425)
771-0220, ext. 1224.
Sincerely,
Development Services Department - Planning Division
MI-100 �01!19
Jen Machuga
Associate Planner
Enclosure: Letter Regarding File No. PLN20110063 dated November 9, 2011
Cc: Scott Shanks via email to scott@fwdsinc.com
/'r) C. I sc)�)
November 9, 2011
CITY OF EDMONDS
121 5th AVENUE NORTH - EDMONDS, WA 98020 - (425) 771-0220 - FAX (425) 771-0221
Websile: vmwdedmondsmg.us
DEVELOPMENT SERVICES DEPARTMENT
Mr. Scott Shanks and Mr. Dale Pinney
First Western Development Services
8129 Lake Ballinger Way, Suite 104
Edmonds, WA 98026
Subject: Request for Additional Information for Your Land Use Application d
For Design Review of the Premier Orthopedic Building at 21401 72n Ave. W
File No. PLN20110063
Dear Mr. Shanks and.Mr. Pinney:
MIKE COOPER
MAYOR
Staff has reviewed your resubmittal materials for your design review application for the proposed Premier
Orthopedic building located at 21401 72 d Avenue West. Thank you for revising your plans to address most of
our concerns related to the design of the building. There are just a few items remaining that need to be
addressed before design review can be completed. Please respond to the following items at your earliest
convenience so that staff s review of your application can continue:
1 . Windows: It was noted that the windows near the center of the eastern fagade were made shorter by
placing a narrow concrete panel at the base of these windows. It appears that these windows. are
located within the "prov. bullpen" room. Is there a reason why these windows are smaller causing an
interruption in the solid row of windows along the third floor? If not, it would look more uniform for
all of these windows along the third floor to be of the same height.
2. PUD Vault: An electrical vault is shown at the northwestern corner of the site. Please note.that the
vault may not be located within the minimum required -four foot street setback from the western
property line if the vault exceeds three feet in height. Is this the only possible location for the vault?
Would it be possible to put the,vault underground or to move it to a less visible location? If the '
northwest comer is the only possible location for the vault, could it be moved a few feet further to the
east so that it is as far back from the western property line aspossible in order to provide enough
space for screening vegetation?
3. Setbacks: The site plan (sbeet A-] 01) indicates that the main entrance to the building will be 4.04 feet
from the western property line, but this plan shows the gold decorative strip on the northern side of the
p
wall of Windows as well 8 the building overhang at the main entrance projecting into the minimum
required 4-foot street setback. Unfortunately, there are no exceptions in the CG site development
standards for any portions of the structure to project into the 4-foot street setback. This can be added
as a. condition of design review approval; however, please note that the plans for the building permit
application,will need to be revised so that all portions of the structure will comply with the 4-foot.
street setback. Additionally, the PUD vault discussed above will also Deed to be shown to comply
with the street setback requirements.
4. P"a et: It was notedthat the parapet on the northern side of the building is taller than the parapets on
the other sides, of the building, creating a step in the parapets at the northeastern and northwestern
comers of the building. Is there a particular reason that the tops of the parapets do not line up in these
locations? Would it be possible to raise or lower the heights of the parapets so that they line up at all
comers of the building?
Incorporated August 11, 1890
Sister City - Hekinan, Japan
0
5. Parkina Garage Screenin : During our meeting on September 20'h, it Was indicated that you would
look into the feasibility of providing a low screening wall on the first floor of the parking garage.
Screening of parking is necessary pursuant to ECDC 16.60.030.A.2.b. It is understood that there are
minimum opening requirements for ventilation of the parking garage since this is proposed to be an
open parking garage. However, based on the Building Division's calculations, it appears that there is
more than enough opening area for the first floor of the garage. As such, a screen similar in style to
the guardrail on the second floor of the parking garage could be utilized to assist with screening the
cars on the first floor of the parking garage. Although the landscaping will assist in partially screening
cars on the first floor of the garage, a more permanent method for screening the cars is desired. This
is partially due to the fact that typically grasses must be cut back significantly or even cut to the
ground during the winter, and even if they are not cut back, they will be more sparse in the winter.
This would greatly reduce any screening provided by the landscaping and causes the need for more
permanent screening of the cars. Of particular concern are the western and southern building fagades,
which can be seen from 72nd Ave. W. Please revise the plans to include a low screening wall (a
minimum of 3.5 feet tall) on at least the western and southern fagades of the first floor of the parking
garage similar in style to that on the second floor of the garage. In addition to helping bring the
proposal into compliance with ECDC 16.60.030.A.2.b, this will also bring the proposal into
compliance with the landscaping requirements of ECDC 20.13.030.C.3.c by utilizing a combination of
opaque "fences" and shrubs to produce a visual barrier of at least 3.5 feet in height to screen the
parking area.
6. Lighting-: Staff s letter sent on September 19, 2011 requested additional information related to
proposed lighting. It does not appear, however, that this item was responded to with your resubmittal.
Please indicate the style and materials of any proposed exterior lighting fixtures.
7. Simap-e: The elevation views that were part of your resubmittal indicate future signage. Please note
that signage will be reviewed for code compliance at the time of submittal of a sign permit application.
However, I wanted to refer you to our sign code requirements of ECDC 20.60 and to bring a few
items related to the signage indicated on the design review plans to your attention at this time. ECDC
20.60.025.A limits the maximum number of permanent signs to three per site, or three per physically
enclosed business space on commercial sites with multiple business tenants. This code section also
limits the total maximum permanent sign area for the site to one square foot per lineal foot of the .
building frontage along 72 nd Ave. W. Additionally, it should be noted that a freestanding sign located
within the four -foot street setback cannot exceed three feet in height. These comments regarding
signage do not need to be responded to at this time, but please note that they will need to be addressed
as well as any additional applicable sign code requirements of ECDC 20.60 upon submittal of a sign
permit application.
8. Landscaping: Note that the following landscaping comments are based on the landscape plan
submitted on October 12, 2011. Although landscaping is shown on the elevation views, it does not
entirely match what is indicated on the landscape plan. Landscaping is not required to be shown on
the elevation views, so any changes being made to the landscape plan do not need to be reflected on
the elevation views. Please respond to the following regarding the landscape plan:
a. Within the plant schedule, update the minimum sizes at installation as follows in order to reflect
the requirements of ECDC 20.13.015.B: Japanese maple should be minimum of 8 feet in height;
arborvitae should be a minimum of 6 feet in height; photinia and vibumum should both be a
minimum of 18 inches in height.
b. The cross -hatching near the southeastern comer of the site surrounding the existing trees to be
retained is not indicated in the plant schedule. Please indicate what this cross -hatching represents.
c. If it is not possible to put the PUD vault underground or to move it to a less prominent location
(see related comment above), please revise the landscape plan to indicate sufficient screening of
the vault from view from the north, west, and south. It is suggested that the vault be moved to
further the east (it must be a minimum of four feet from the western property line if over three feet
in height) in order to provide sufficient space for screening landscaping. Instead of screening it
Page 2 of 3
1. 0
with grasses, it is suggested that the vault be screened with taller evergreen shrubs that will grow
to be higher than the height of the vault itself.
d. The landscape plan indicates six fastigiate white pine trees along the western side of the site.
Although this species starts out as a columnar tree, as it ages,.it can mature at up to 60 feet tall
and 15 to 20 feet wide. This is of concern on the western side of the site where there is only
approximately 10 feet between the building and the western property line, which could cause the
need for major pruning or even removal of these trees in the future. It is suggested that you
consider a smaller evergreen that is more suitably sized for the western side of the site, such as a
columnar Norway spruce (Picea abies cupressina), which grows to approximately 30 to 40 feet in
height and 8 to 10 feet in width.
e. Landscaping along all four sides of the site is required to comply with the Type III landscaping
requirements. Please describe how each side of the site is in compliance with the Type III
requirements of ECDC 20.13.03O.C.
f. During our meeting on September 20'h, it was suggested that a combination of a taller species,
such as arborvitae, be utilized in combination with a smaller shrub along the northern side of the
property in order to he ' 1p break up the northern fa�ade and to achieve Type III landscaping.
Would it be possible to establish arborvitae or another taller species at a minimum of 30 foot
intervals along the northern side of the site adjacent to the walkway?
g. It is suggested that evergreen shrubs, such as the compact strawberry tree or Fraser's photinia that
are utilized on the eastern side of the site, be established amongst the grasses on the western and
southern sides of the site in order to add some height to the landscaping adjacent to the open bays
of the parking garage and to provide denser, year-round vegetation in these areas of the site.
h. Please provide written acknowledgement from the property owner that they understand that if the
existing trees that are proposed to be retained near the southeastern corner. of the site and/or the
existing trees that are to be transplanted near the southern side of the site do not survive during the
construction project, a landscape plan revision may berequired and new trees may be necessary
near these locations.
9. Enp-ineerinp- Division Review: It should be noted that the Engineering Division has approved the
subject design review application and issued the attached memo on November 8, 2011. Any
remaining comments from the Engineering Division, including comments on the proposed civil plans,
will be provided during their review of the associated building permit applications.
Please note that your application will be placed on hold until a response is received regarding the above items,
Pursuant to ECDC Section 20.02.003.13, you must submit the above information within 90 days. Thus, your
application will expire if the requested information is not received by February 7, 2012.
If you have any questions, please do not hesitate to contact me at (425) 771-0220, extension 1224.
Sincerely;
Development Services Department - Planning Division
Jen Machuga
Associate'Planner
Enclosure: Memorandum from Jeanie McConnell dated November 8, 2011
Cc: File No. PLN20110063
Page 3 qf 3
MEMORANDUM
Date: November 8, 2011
To: Jen Machuga, Planner
From: Jeanie McConnell, Engineering Program Manager
Subject: PLN20110063
21401-72 nd Ave W — Kruger Orthopedic Clinic
Engineering has reviewed and approved the subject design review application with the
following comments noted to be noted in the staff report.
1) Compliance with Engineering codes and construction standards will be reviewed with the
building permit application for development of the site.
2) Approval of the desip review phase of the project does not constitute approval of the
improvements as shown on the submitted plans.
3) Applicant is encouraged, wherever feasible, to incorporate pervious pavements, rain
gardens and/or other low impact development techniques into the project design.
Thank you.
City of Edmonds
Ir F
`MEMORANDUM
Date: November 9, 2011
To: Jim Wieben, DDG Architects
From: John Westfall, Fire Marshal
Subject: Bid 2011-0815 Premier Orthopedic Shell 21401 72 nd Ave W
The Fire Department provides the following comments and corrections in accordance with the 2009
International Fire Code and Edmonds Community Development Code Title 19:
G-001 General Notes:
a. #1: add "...and NFPA 101"
b. #18 & A-101: Are UG storage tanks identified on -site that will require decommissioning?
c. #25: IFC Chapter 14 is reference for construction, demolition and equipment
serviceability.
d. #27: Add: Provide Snohomish County FD#1 Knox box. Coordinate with Fire Department
for authorization form and instructions to obtain and install lockbox outside the sprinkler
room on your site. 425.775.7720
2. G-001 Deferred Submittals:
a. Add Fire Connection Permit (may be part of civil plans)
b. Add Fire Protection Footprint (below)
c. Delete Grease Hood
3. G-001 or A-201: Add note: New buildings shall have approved address numbers, building
numbers or approved building identification placed in a position that is plainly legible and visible
from the street or road fronting the property. These numbers shall contrast with their installed
background. Address numbers shall be Arabic numerals or alphabet letters. Building numbers
shall be a minimum of 6 inches high with a minimum stroke width of Y2 inch and proportionate to
building size.
4. CS Code Summary:
a. Provide compass north this sheet.
b. Clarify start and finish points and paths for EXIT TRAVEL DISTANCEs.
c. What is NE corner swing gate opening function on first floor?
5. A-101: Provide specifications on emergency generator; fuel type & capacity. Callout setback
distances from generator to property line and to building.
6. A-1 11 & A-1 12: callout portable fire extinguisher locations. (G-001 GENERAL NOTE #8)
City of Edmonds Sb Office of Fire Marshal
7. A-1 11 & A-1 17 Door 110 for medical gas is not rated and assumed to be designed and
exhausted as a one -hour interior room (IFC 3006.2.2).
8. A-1 11: Add note for FIRE SPRINKLER ROOM: "Space temperature no less than 40 degrees F."
9. A-1 11 What STORAGE anticipated for under ramp? Is this calculated in S-1 storage area?
10. A-1 11 & Al 19: Callout interior doors for stairwells #2 and #3 (same as 204 & 206?).
11. A-1 12: Callout room use at NW corner.
12. A-1 17: Callout where EXIT STAIR BARRIER GATEs (detail 2) will be installed.
13. A-1 19 OVERHEAD SECTIONAL DOOR type s/b "E" vs. "D"?
14. A-1 19 Recalculate door type and remarks for door 107 at exterior sprinkler riser room.
15. A-201 Provide vertical clearance signs for west and east (gate) vehicle entries.
Attachment: Fire Protection Footprint
Edmonds Plaza
1500 Main Street
Occupancl a: R1, A3, 8, M
0
Typo of Construction: V 1-hour
2 stories w:th basement
Total Build ng Area: 32,456 at
1997 UBC, UMC, UFC, UPC, WSEC. VIAQ, State Barrier Free Code
Fire Apparatus Access: Paved West, South and East sides
Active Fire Protection
Fire sprinkler system (specify USC Std. 9-1 or 9.3) 1
Fire sprinkler control panel location
Fire Department connections
Fire alarm system w/ smoke detection and manual pulls
Fire alarm control panel location
Illuminated exit signs
Emergency lighting w/ battery back-up P.
HVAC automatic shutdown
Kitchen Type I hood and suppression system
Fire Extinguishers 0.1
Passive Fire Protection
Smoke control system
Escape windows from sleeping rooms
I -hour rated corridor/exit passageway
Attic draft stops
Elevator smoke door
Structural Protection
Exterior load-boarling walls
= 1 -hour
Interior load -bearing walls
- 1 -hour
I Exterior non -bearing walls
- 1 -hour
Structural frame
- 1-hour
Permanent partitions
- 1 -hour
Shaft enc ures
1 -hour
FIoorZl:n039
1-hour
Roof -col ng
11-hour
Exterior openings
NIA due to location on property
Stair enclosure
1-hour
Roof material class
Type B
cc: Assistant Building Official Leif Bjorback
Dwelling Unit
Dwelling Unit
Dwelling Unit
Retail
nA (A).
A
Reatiturani
A
Ele�.
Lobb,
Ele,
Office
office
()it=
LEGEND
1 hour Corridor with sell-
dw no rated doc,,s, mted
Dwelling Unit
glaz:ng: Oralsmake dompm at
— — — — — -
duct ponetralloris
I hour rated wall assembly
Dwelling Unit
2 hoxw Area Separation Wag
With led doors and glazing
Retputred exit to the exterior
or the building
Dwelling Unit
Area of Evacuation Assistance
ro ronent Corinection
20 min. rated, seff-closN door
ago
6D rrdn. rated. self -dosing door
go min. rated. 3elf-closing door
D.welling Unit
Dwelling Unit
Dwelling Unit
Dwelling Unit
Dwelling Unit
— N
FIRST FLOOR
OT E D 40
Sample Fire
Protection
Footprint
Date Prepared
Last Updated
2
6 0
City of Edmonds Wastewater Pretreatment Program
2002 d Ave S., Edmonds, WA 98620
Office: (425) 672-5755 Mobile: (206) 595-3117
Plan Review Comments
Plan Check #: BLD20110815 Date: Oct. 10, 2011
Project Name/ Address: Edmonds Medical Bldjz. Assoc., LLC, 2140172 d Ave W., Edmonds
Contact Person/Fax or Email: Wieben, Jim/ jimw@ddizarchitects.com
Reviewer: Jon Lein Division: Wastewater Treatment Plant / Pretreatment
The subject application has been reviewed but cannot be completed until the following
items have been addressed/completed. Please submit'3 sets of revised drawings to a
Development Services Permit Coordinator, if required, or a written response to the review
comments to the Development Services Permit Coordinator and the Pretreatment
Reviewer.
1 . In reviewing the civil plans, I did not see an oil/water separator included that served the
parking levels. I am thinking that since the elevations are critical for the oil/water
separator design, they should be included in the civil plans. Generally, any parking
garage that has drains and/or hose bibs at the parking levels will require an approved
oil/water separator. The Edmonds Building Department will make the final
determination for the oil/water separator.
2. Please explain how the clinic will properly dispose of pharmaceuticals, pain killers, and
anesthesia products when expired and also residual waste products from clinic
procedures.
3. Please include disposal meihods for all hazardous materials not listed above such as
sterilizers, disinfectants, human blood and tissue, syringes, and all other chemicals and
supplies that will be used at the clinic.
4. 1 noticed a laundry facility on the clinic floor. Please include a brief description of the
laundry operations that include an estimate of loads per week, detergents, bleaches,
conditioners, and all other additives for the laundry load. .
The reply for this review could be somewhat burdensome, but its purpose is to prevent the
introduction of products/chemicals into the sanitary sewer that could be harmful to the
wastewater treatment plant biology, the receiving waters (by pass -through of hazardous material
and pharmaceuticals through the wastewater treatment plant), and for City workers performing
maintenance in the collection system. Thank you for your assistance.
Please call me Monday -Thursday for questions and assistance.
Jon Lein
City of Edmonds Pretreatment Technician
425-672-5755
206-595-3117 cell
OV EDV 0 City of Edmond
REQUEST FOR PLAN REVIEW CONSULTANT SERVICES
BUILDING DIVISION
(425) 771-0220
Task Order No. Budget Line Number: 001.000.620.524.100.410
Project Name & Plan Check # OZJ�5-
Consultant: EAGLE EYE ENGINEERS Consultant Contact Person: Hoyt Jeter Phone: 360-874-0562
Fax: 360-874-0591
City of Edmonds Requester: Leonard Yarbegy, Building Official Phone: 425-771-0220 extri 1226
Reimbursable by Applicant:
El Yes, by
(Name, address, phone number of person/organization who will reimburse City)
39, No
DESCRIPTION OF TASK ASSIGNMENT
Review the enclosed plans, calculations and documents, for compliance with State and City adopted building codes
F� Structural & Non -Structural Plan Review F-1 Fire Sprinkler Plan Review
;K Structural Only Plan Review El Non -Structural Only Plan Review
Additional Instructions:
COMPENSATION
BASED ON CONSTRUCTION VALUATION per Professional Services Agreement
F� TIME AND MATERIALS per Professional Services Agreement. Compensation for these services will be on a Time
and Materials basis, not to exceed $ without written authorization.
SCHEDULE The Consultant shall complete the services described above as follows:
1�4 In accordance with Standard Review Timelines per t�e Prcpssional Services Agreement
Completed 1" review due to City b jz� 11W)l (see below for subsequent reviews)
1. -
F-I Alternate review time as agreed upon in advance with Ze City per the Professional Services Agreement (only to be used
when approved by the Building Official).
0 Completed review due to City by (see below for subsequent reviews)
All provisions of the Professional Services Agreement dated 10/26/2009 shall be in full force and effect for this Task Order.
APPROVED:
CITY OTFMO�. S CONSULTANT
By: By -
Leonard Yarb—eA% Build7ing"O�al Date Hoyt Jeter, President Date
RETURN ORIGINAL SIGNED TASK ORDER TO THE CITY
SCHEDULE OF SUBSEQUENT REVIEWS:
2 nd REVIEW DUE TO CITY BY:
3rd REVIEW DUE TO CITY BY:
L:\TEMP\DST's\Forms\Task Order Forms\Eagle Eye Engineers Task Order Form.doc
0
City of Edmonds
Plan Review Corrections
Plan Check # �J J 2,n, 1/ 08 /,T— Date �C 10 —,57— IZ
Project Name/Address
Z-
Contact Person/Address 2-V ff-0.1 - 712=� L-J
Department: Building Engineering Planning Fire Public Works
Reviewer
DO
Submit 2 sets of revised plans/documents to the Permit Coordinator.
Corrections may be,made by red lining plans/documents on rile with the City.
DATEFAXED (Attach fax. transmittal) PAGE —OF
OV ED&
CITY OF EDMONDS
121 5TH AVENUE NORTH - EDMONDS, WA 98020
PHONE: (425) 771-0220 - FAX: (425) 771-0221
Monday, September 26, 2011
This Application has been accepted by the City of Edmonds for review. More information and changes may be
required during this process. The review target date is: Monday, November 07, 2011
Your City Contact is: MARIE HARRISON
Application Number: BLD20110815
Project Address: 21401 72ND AVE W, EDMONDS
EDMONDS MEDICAL BUILDING ASSOC., LLC DDG ARCHITECTS
8129 LAKE BALLINGER WAY JIM WIEBEN
EDMONDS, WA 98026 16398 NE 85TH STREET
(425) 329-0848 EXT: REDMOND, WA 98052
(425) 289-5805 EXT:
Work Description:
3 STORY BUILDING CONTAINING OFFICES AND TWO FLOORS OF PARKING. SHELLANDCORE
PERMIT
Outstanding Items at Time of Submittal:
CIVIL DRAWINGS
I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION THAT THE INFORMATION GIVEN IS CORRECT
AND THAT I A . THE PROPERTY OWNER, OR THE DULY AUTHORIZED AGENT OF THE PROPERTY OWNER TO SUBMIT
A BUILDING PERMIT APPLICA71ON TO THE CITY.
OR AGENT) PRINT NAME
(0
TE SH
To view up to date information about your application please visit the City of Edmonds Development Services
website at http.1Avww.c4edmonds.wa.us.
of EDAf 0
un DEVELOPMENT SERVICES
COMMERCIAL & MULTI -FAMILY BUILDING
PERMIT APPLICATION
121 5h Avenue N, Edmonds, WA 98020
City of Edmonds Phone 425.771.0220 It Fax 425.771.0221
PLEASE REFER TO THE COMMERCIAL & MUL TI-FAMIL Y B UILDING CHECKLIST FOR SUBM17TAL REQ UIREMENTS
PROJECT ADDRESS (Street, Suite #, City State, Zip):
I ( 4-o 1 '79- IJ D 4xi a W Lnpm ai, )tz�
Parcel #:
-
Subdivision/Lot #:
io7'c,
Project Valuation: $
APPLICANT:
017& ��/ , -,J;H
Phone: CXT-
4 2-5 - �W -15t'P_'0'5
Fax:
Address (Street, City State Zip):
3-7 pep�_Wp,
WA q8052.
E-Mail Address
cazz��
PROPERTY OWNER:
6t6 Cj:f, L.,'
5 - , L_
Phone:
0
425-1241- i 42)
ax:
FF�
Address (Street, City, State, Zip):
0 12.9 L^YZ- e-�"
I
E-Mail Address:
-*e-qr (F, e'cm
LENDING AGENCY:
Phone:
Fax:
Address (Street, City, State, Zip):
E-Mail Address:
C
,RNTRACTOR--
re2-itivo &sx7/
Phone:
e2d c- - 4- 1 e) -
Fax:
Address (Street, City, State, Zip): 5 3-0'3
E-Mail Address IC167AIAIrcc
43 <Z2--3.
*Contractor must have a valid City ofEdmonds business license prior to
doing work in the City. Contact the City Clerk's Office at 425.775.2525
s- W/E
WA State Licen e - xp. Dat
City Business License #/Exp. Date:
Al A
DETAIL SCOPE OF WORK:
_rkk) 42r rN944Wt,_1 I
Irk
7J r
_TP F_> 95Z10 CS er
f? LP& - A1QEA T f kM q- f HES
r+ tjoW �qp (W_Lk�, P.5 A"54� A41s-
13tFilob
PROPOSED NEW SOUARE F
OTAGE FOR THIS PROJECT:
Basement: A/A sq. ft.
Garage: AIA -sq, ft,
I' Floor: Z -�Ei6 sq*. ft.
Deck: sq. ft.
2 n' Floor: 22, 3 e6 sq. ft.
Other: sq. ft.
77—Floor: 21, -3 sA sq.
Occupancy: F75�-Z Occupancy Load: �2,�� 1
Retaining Wall: 0 Yes ><No
Grading: cyds.
I Type of Construction: 11-15
I declare underpenalty ofperjuiy laws that the information Ihaveprovided on thisfornVapplication is true, correct and
complete, andthatIam theproperty owner or duly authorized agent of theproperty owner to submit apermit application to
the City of Edmonds.
PrintName: "J'kMVr='. 0 Owner KAgent/Other (specify): AACAfteZl
Signaturec Date:
FORME LABuilding New Folder 2010\DONE & x-ferred to L-Building-New drive\Form E.doc Updated: 10/2010
17�
Equipment Type
Appliance/Equipment Information (new and relocated)
Total #
Furnace
#—Gas
#—Elec
#—Other:
BTUs: <100k >100k—
Location
Air Handier/ACIVAV
#—Gas
#—Elec
#—Other:
CFM: <1 OOk— >1 OOk—
Location
Boiier/Compressor/
Heat Pump/Roof Top
Unit
#
HP:
Gas #
—<3,
Elec #
_3-15,
Other: BTUs: <100k,
16-30 Location
100k-500k, 500k-IMil
Hydronic Heating
#—Gas
#—Elec
—in-Floor,
—Wall Radiant, Boiler BTUs:
Location
Exhaust Fans (single
duct)
Location: #
Bath #
Kitchen # Laundry # _Other:
Fireplace
#
Gas #—Elec
#—Other:
Location
Other
Number of Outlets
Fixture/Appliance Type
AC Unit — - — — ------- BTUs: Location:
Furnace --------------- BTUs: Location:
Water Heater -------- BTUs: Location:
Boiler ------------------ BTUs: Location:
Firep!ace/Insert BTUs:— Location:
Stove/Range/Oven:
Dryer
Outdoor BBQ:
Other:
TOTAL OUTLETS
PLUMBING FIXTURE COUNT
Number
Fixture Type
Number
Fixture Type
Water Closet (Toilet)
Refrigerator water supply (for water/ice dispenser)
Sink (kitchen, laundry, lavatory, bar, eye wash, etc.)
Water Service Line
Tub/Shower
Drinking Fountain
Dishwasher
Bidet/Urinal
Hose Bib
Pressure Reduction Valve/Pressure Regulator
Water Heater Tankless? Yes— No—
Backflow Prevention Device (eg. RBPA, DCDA, AVB)
Expansion Tank for Water Heater
Hydronic Heat in: Floor Wall
Floor Drain/Floor Sink
Other
Clothes Washer
Other:
FORME L:\Buil ding New Folder 201 O\DONE & x-ferred to L-Building-New drive\Fonn E. doc Updated: 10/2010
Al OV ED 0
DEVELOPMENT SERVICES
COMMERCIAL & MULTI -FAMILY BUILDING CHECKLIST
121 5h Avenue N, Edmonds, WA 98020
Phone 425.771.0220 It Fax 425.771.0221
City of Edmonds
PROJECT ADDRESS:
PRE -APPLICATION MEETING? 0 YES 0 NO If YES, Pre -application Number:
Plans shall be of sufficient clarity to indicate the location, nature, and extent of the work proposed, and conform to the provisions of
the adopted International Codes and City Ordinances.
r) >
SUBMITTAL REQUIREMENTS
The number indicates the number of copiesfor
submittal(if applicable). Check marks indicate
additional submittal requirement as applicable
ko 2
ft
CL
'A
CD
:z
n
=r
L�
*A *A
0
v,,"
Application Form E
I
I
I
I
I
I
Site Plan
3
3
3
3
3
3
Reduced Site Plan (I I X 14 or 8 1/2 x 11)
1
1
1
1
1
1
Architectural Construction Drawings
3
3
3
3
3
3
Structural Drawing and Calculations
3
3
3
1 3
WA State Energy Code NREC Calcs & Lighting
V/
V/
V/
V/
Site Classification Worksheet
3
3
Site Development Plans
4
4
v"
Landscape Plan
3
3
Right —o Way Permit Application
I
I
I
Critical Areas Determination or Checklist
I
I
I
V'
Geotechnical Report
3
3
Health District Approval Letter
V
I/
Manufacturer's Specifications/Cut Sheets
3
Contractor's City of Edmonds Business License
V/
V/
V/
V/
V/
V/
Washington State Contractors License
V
V
V
V/
V
V/
Plan Check Fee (due upon submittal)
V/
V
V/
V11
V/
Traffic Impact Analysis
3
3
3
3
Survey
3
3
Special Inspection and Testing Agreement
V/
V/
V/
V/
Contractor's Acknowledgement Letter
V/
V/
Envelope Plans and Documents
2
2
Bonds
I
I
V/
Architectural Design Approval
I
I
Peer Review Fees
V/
V/
Deferred Submittals
V/
V/
Shop Drawings
V/
Street Use
V/
Handouts and Standard Details may be found on the City's website www.ci.edmonds.wa.us or can be obtained at City Hall
during normal business hours.
Plans/calculation/reports prepared by state licensed architects or professional engineers must be stamped and signed by the
design professional.
FORN4E LABuilding New Folder 2010\130NE & x-ferred to L-Building-New drive\Form E.doc Updated: 10/2010
ov. tO 410
A%1�49011i&6
P DEVELOPMENT SERVICES
COMMERCIAL & MULTI -FAMILY BUILDING
PERMIT APPLICATION
q" � vp.., 121 5h Avenue N, Edmonds, WA 98020
St. I S9
City of Edmonds Phone 425.771.0220 It Fax 425.771.0221
PLEASE REFER TO THE COMMERCIAL & MULTI -FAMILY BUILDING CHECKLIST FOR SUBMITTAL REQUIREMENTS
PROJECT ADDRESS (Street, Suite # City State, Zip):
'Z 1 1401 _IShP 4jS W - 613nVAM
Parcel #:
Subdivision/Lot #:
Pjpject Valuation: $
llr>500, 000
APPLICANT:
Phone:
Fax:
Address (Street, City, S te Zip):
mo2-je M
2L4Fhone:
E-Mail Address-
jlm��JAJ
PROPERTY OWNER:
mepe4u, B u)& Asfd--.
u
�_ 426 - 3 1-1
Fax:
Address (Street, City, State, Zip):
44LE 3AW"Z0 !!!ti MMOAD6
E-Mail ddress:
-A
W S n e, Com
LENDING AGENCY:
Phone:
Fax:
Address (Street, City, State, Zip):
E-Mail Address:
CONTRACTOR:*
re)jW0*)
Phone:
00r0_44&
Fax:
Address (Street, City, State, Zip):
WA State License #/Exp. Date:
*Comractor must have a valid City ofEdmonds business'license prior to doing work in the
City. Contact the City Clerk's Office at 425.775.2525
City Business License #/Exp. Date:
DETAIL SCOPE OF WORK:
Avv) oiiwit�k 4AI-51M 151��
aVIM, 4 45"rler4m
BOLL, ft4lu 4v&z,
.)39AfAJAY_-&
I
PROPOSED NEW SQUARE FOOTAGE
FOR THIS PROJECT:
Basement: sq. ft.
Garage: sq, ft,
V Floor: sq. ft.
Deck: -sq. ft.
2 d Floor: sq. ft.
Other: sq. ft.
3'd Floor: sq. ft.
Occupancy: Occupancy Load:
Retaining Wall: 0 Yes 40
Grading: _____cyds.
I Type of Constructi7on- 7W
I declare underpenalty ofperjury laws that the information I have provided on this jormlapplication is true, correct and
complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to
the City of Edmonds.
Print Name: _Ij 0 Owner t/Other (specify):
Signature: _< \ Date: I ;/I I
M
FORM E CADocurnents and Settings%jorback�DesktopTonn Edoc Updated: 10/2010
0
0
STATEMENT OF PLAN REVIEW SERVICES AGREEMENT
ACKNOWLEDGEMENT OF REQUIRED
DISCRETIONARY APPROVALS
13 o�) 4,eM, am the owner/agent for the owner, for a
building permit to construction improvements upon real property located at:
-72,00 ANM W W-T- r-=D�Ds W.4
in Edmonds, Washington. I acknowledge that, pursuant to terms of this agreement, the Building Permit
Application I have submitted will be accepted for review by the City concurrently with the review of any
necessary discretionary project permits or approvals required by the provisions of the Edmonds
Community Development Code. I also acknowledge that the City shall not accept an application for
building permit that is not complete as determined by the minimum submittal requirements published by
the City which I have read and understand.- In signing this form, I acknowledge that I have submitted all
necessary documentation in order to make a complete application for a building permit. The City
determined that the discretionary application(s) for this project were deemed complete on _ (date).
I acknowledge that any plan review fees paid in connection with this application are solely for the
expenses and costs associated with review the plans as I have submitted thern, and do not entitle me to
any right or claim to the issuance of a building permit. In consideration for the consolidated review of the
building permit application concurrently with any required discretionary. project permits or approvals, I
hereby acknowledge and agree to be bound by. terms and conditions of this agreement as, set for herein.
1. The required discretionary project permits or approvals for this project currently include, but are not
limited to the following:
Architectural design .......... Hearingdate: PA. A&,!�X,,
A —
F] Subdivision or short subdivision ................................... Hearing date:
F1 Planned residential development ................................... Hearing date:
Conditional use permit ................................................... Hearing date:
nV
ariance ......................................................................... . Hearing date:
F] Critical areas determination or variance request ............. Hearing date:
[] Other (specify) Hearing date-.
I further understand that additional discretionary project permits or approvals may be determined
during the course of discretionary project review which may affect plan review timelines and plan
review fees paid for this building permit application.
2. Any building permit issued and approved for this project will be subject to any conditions or
restrictions imposed pursuant to the review and approval of any required discretionary project permits
or approvals. Such conditions or restrictions may require that the building plans I have submitted be
modified or amended to be consistent with such conditions or restrictions. I understand that additional
plan review fees will be required in the event that modifications or amendments to the plans
submitted are required by conditions or restrictions imposed pursuant to a final decision to issue or
grant any required discretionary project permits or approvals. In the event that modifications or
amendments are required, the owner shall be solely responsible for any and all costs which result
therefrom, including, but not limited to, additional full plan review fees. When additional plan review
fees are required, the fees shall be paid in full prior to, the commencement of additional plan review
by the City.
3. No building permit will be approved or issued until such time as a final decision for all required
discretionary project permits or approvals have been. issued or granted, including the expiration of all
appeal periods. A decision to issue or approve any required discretionary project permit or approval
shall not be considered final until the limitations period for any appeal has expired or until all
administrative and Superior Court appeals have been resolved. In the event that an appeal of a
discretionary project permit or approval results in new or additional conditions or restrictions which
require modifications or amendments to the building plans, such conditions and restrictions shall be
treated as if originally imposed in the issuance or granting of the discretionary permit or approval.
However, new full -plan review fees shall be required.
4. The building pen -nit application shall expire 180 days after the building permit submittal regardless of
whether a final decision, including'expiration of appeal periods, for all discretionary project permits
or approvals have been issued or granted. I understand that I may request a building permit
application extension for an additional 180 days, in writing, if filed before the expiration of the
original application. The City may grant only one extension. In the event that the building permit
application expires prior to a final decision on the issuance or approval of all required discretionary
permits or approvals; or if not request for an extension is submitted in writing prior the expiration of
the original application, then the appli cation shall expire and'a new applicati on and new full -plan
review fees will be required.
5. In the event that any application for a required discretionary project permit or approval is withdrawn,
or if such permit or approval is denied either by the City or upon appeal, no portion of any plan
review fee shall be refunded by the City.
6. In the event that the building permit applicant initiates or requests amendments or modifications to
the building plans after plan review by an applicable City Department is complete, new full -plan
review fees will be required and shall be required to be paidin full prior to the commencement of
additional plan review by the City.
I certify that I have read and understand the terms and provisions of this agreement for plan review
services and agree to be bound by such.
Owner/Agent of Owne?-�-._ Date: OV41 2.01)
Development Services Permit Coordinator
statement of plan review sery agree.doc 2
01.17.2001
FJL
Of 0
1P CITY OF EDMONDS
pool, 121 5" Avenue North - Edmonds, WA 98020
Phone: 425.771.0220 - Fax: 425.771.0221 - Web: www.ci.edmonds.wa.us
DEVELOPMENT SERVICES DEPARTMENT: PLANNING DIVISION
Pre -Application Meeting
Meeting Date:
June 9, 2011 at 1:30pm
Review By:
Jeri Machuga, Planning Division
Site Address:
21401-72 nd Avenue West
Zone:
General Commercial (CG2)
Project Description:
Proposal for a new medical office building, with the first two floors comprised of parking
d the third floor comprised of approximately 26,000 square feet of medical office space. _J
Zoning
The current zoning of the subject property is General Commercial, CG2. Properties within the CG2 zone are subject
to the requirements of Edmonds Community Development Code (ECDC) Chapter 16.60.
Proposed Use
The proposal is for a new medical office building, which is an allowed use within the CG2 zone.
Development Standards
Setbacks: Per ECDC 16.60.020, the CG2 zone requires the following property line setbacks:
Street setback 4 feet from the western property line (the street setback area shall be fully landscaped)
Side setbacks 0 feet (none required since subject property is not adjacent to a residential zone)
Rear setback 0 feet (none required since subject property is not adjacent to a residential zone)
HdgbLt: The maximum allowed height of structures within the CG2 zone is 75 feet; however, due to the site's
location within the high rise node overlay of the Comprehensive Plan, there is no height limit. Design review for
projects not exceeding the 75-foot height limit is administrative; however, projects exceeding the height limit
require design review by the Architectural Design Board (ADB). It appears that the proposed building will be well
below 75 feet in height, so staff's comments are based on this assumption. Since going above the 75-foot height
limit triggers design review by the ADB, height calculations will need to be provided on the building permit plans.
Refer to ECDC 21.40.030 for the definition of height and explanation of how it is calculated.
Parking Requirements
The minimum on -site parking requirement for medical offices is one parking space per 200 square feet pursuant to
ECDC 17.50.020.B.4. Upon preliminary revi ect plans, it appears that not enough parking spaces are
being provided -to comply with this requirement. Thus, the plans will need to be revised and it will need to be shown
during building permit application review that the proposal complieswith the on -site parking requirements.
Environmental Regulations
Critical Area Determination: A critical areas checklist and associated review fee ($155) must be submitted in order
for staff to conduct a critical areas determination for the site. This must be completed prior to or concurrently with
permit review. If it is found that the site contains or is adjacent to any critical areas as defined in ECDC 23.40
through 23.90, a critical areas study may be required during permit review in order to determine compliance with all
applicable critical areas regulations.
Page I of 3
SEPA Review: SEPA review is required because the project includes over 4,000 square feet of commercial space
and over 20 parking stalls. SEPA review will be conducted concurrently with design review or building permit
application review. Typically, if an application for design review is made prior to the building permit application,
SEPA review will be conducted at the time of the design review application. For SEPA review, a completed
environmental checklist, adjacent property owner's list, and $485 fee must be submitted.
Design Review
"District -Based" design review is required. Refer to ECDC 20. 10 and 20.12 for procedures and criteria. Since the
proposal appears to be below the 75-foot height limit, design review will be an administrative Type I decision. It is
recommended that design review be conducted prior to submittal for the building permit application so that any
changes that must be made to the building design in order to comply with applicable design regulations do not result
in the need to update detailed architectural drawings. Alternatively, the applicant may submit for design review
concurrently with the building permit application with the understanding that any changes that must be made to the
building design could result in major changes to the plans submitted for the building permit application. The fee for
administrative "District -Based" design review for projects that also trigger SEPA review is $570. If an application
for design review is submitted prior to the building permit application, an additional $15 city surcharge is necessary,
and a Land Use Application form must also be submitted. During design review, the proposal will be reviewed for
compliance with the applicable design standards of ECDC 16.60.030 and the Comprehensive Plan.
Comprehensive Plan
The Comprehensive Plan -designation for the site is "Highway 99 Corridor," and the site is also located within the
"Hi -Rise Node." Refer to the general urban design objectives contained within pages 92 through 100 of the
Comprehensive Plan for additional information on design objectives applicable to the project.
Landscaping Requirements
Refer to ECDC 20.13 for landscaping types and requirements. Additionally, the design standards within ECDC
16.60.030 address landscaping requirements as well. It should be noted that Type IV landscaping a minimum of
four feet in width and continuous in length (aside from access points to the building) is required within the street
setback on the western side of the site, and Type III landscaping a minimum of three feet in width and continuous in
length is required wherever the building does not go completely up to the property line. .
Signage
Refer to ECDC 20.60 for the city's sign code requirements.
Changes to the Edmonds Community Development Code
The City is currently in the process of updating portions of the Edmonds Community Development Code. Please
note that the comments and fees provided above and during the pre -application meeting are based on current code
requirements. The applicant is responsible for ensuring compliance with the codes and fees that are applicable at the
time of submittal.
Required Permits and Approvalsfrom Other Jurisdictions
It should be noted that the applicant is responsible fo r obtaining all required permits and approvals from any
applicable federal, state, or local jurisdictions.
Code References
All Edmonds Community Development Code (ECDC) references made in, these comments can be viewed via the
"QuickLinks" link on the City's website at www.ci.edmonds.wa.us.
Page 2 of 3
Attachments lEnclosures
• Summary of Commercial Site Development Standards (#P77b)
• Land Use Application Form
• Critical Areas Cbecklist (#P20)
• SEPA Environmental Cbecklist (#P71)
• Instructions on How to Compile an Adjacent Property Owner List (#P2)
• District -Based Design Review (#P6)
Page 3 of 3
ov
0
City of Edmonds
PRIE-APPLICATION COMMENTS
BUILDING DIVISION
DATE June 9, 2011
STAFF: Leif Bjorback, Assistant Building Official
RE: Project: Medical Office Building
A preliminary review. was done with the pre -application materials provided and we have the
following comments.
1) Codes in effect at the time of this meeting:
a) 2009 International Building Code (including Accessibility) with State Amendments
b) 2009 International Mechanical Code (including International Fuel Gas Code) with State
Amendments
c) 2009 International Fire Code with State Amendments
d) 2009 Uniform Plumbing Code with State Amendments
e) 2009 Washington State Energy Code (WAC 51-11)
0 Edmonds Community Development Code
2) Basic Design Loads specific to Edmonds
a) Snow load 25 psf — nonreducible
b) Seismic design category D
c) Wind speed 85 mph, 3 sec gust
d) Wind exposure most likely B for this location
3) List all deferred submittals on the cover sheet of the plans. The City prefers that me'chanical
and plumbing plans be included with and issued with the main building permit to help avoid
any construction delays, however they can be deferred. Other commonly deferred items are fire
sprinkler, fire alarm, signs, side sewer, water meter, State electrical, State elevator, shop
drawings, etc. 1
4) -Plans must be stamped by a State licensed Architect or Professional Engineer, including
structural plans and calculations.
5) A soils report is required for this project. See Handout B 18.
6) A separate Shoring Plan, stamped and signed by a Washington State Licensed Engineer, shall
be submitted for property line cuts in excess of three (3) feet in height or when required by the
Engineering Geologist/Geotdchnical Engineer who prepared the soils report. Shoring is subject
to outside peer review by a City consultant at full cost to the applicant. See Handout B 18 for
more information.
7) Provide allowable area calculations on the plans. Include justification for allowable area and
height increases according to the type of construction. IBC 503, 504 and 506.
Building Division Pre -application Conunents I
8) Clearly show on the plans how this building is designed per EBC 508 for separated uses, non -
separated uses, incidental accessory occupancies, etc. If separated uses will be used, mixed -use
ratio calculations are required.
9) Provide occupant load calculations for each floor and the total building.
10) An automatic sprinkler system is required for the building. See Fire Marshal's comments for
fire alarm and automatic sprinkler system requirements.
11) Provide details of fire rated walls, floor -ceilings, and projections on the plans, including the
complete listed and tested fire rated assemblies and cross-reference where they apply on the
plans.
12) Common path of egress travel within the various occupancy group spaces shall be regulated by
E3C 1014.3.
13) The building.and site must be barrier free accessible including the main entrance, restrooms,
maneuvering distances, parking, pedestrian access from the public street, mailboxes, trash
enclosure, etc. Provide details showing compliance. E3C chapter 11
14) Accessible parking stalls shall be provided per E3C 1106. At least one stall shall be van
accessible, with a minimum 16 foot width, including access aisle. Note that the minimum
ceiling height, for vehicle access to accessible parking is 98 inches. Columns (including
finished materials) cannot encroach within the required widths/lengths of the parking stalls.
15) Provide Non -Residential Energy Code compliance forms for envelope, mechanical, interior
and exterior lighting and metering. These forms are available on line at
http://www.neec.net/documents.
16) Ventilation of the commercial spaces must be provided either mechanically ��r with natural
ventilation using building openings (windows and doors) in accordance with the E3C and
IMC.
a) Natural ventilation: Provide in each room or area at the rate 4% of the floor area. Show
the calculations on the plans. OR
b) Mechanical ventilation: Provide outdoor air at the rates specified in IMC Table 403.3
(based on the occupant load established in #9 above) to each room or area. The system
must be balanced (supply and retum/exhaust). Provide mechanical plans and calculations
showing compliance. Provide manufacturer's specs for the mechanical units to be
installed.
17) Show all mechanical shaft locations on the plans. Commonly, issues arise with the garage
exhaust and elevator equipment room ventilation. Parking garage. ventilation (supply and
exhaust) shall be designed per E3C 406 and WC 404. Show location of supply air inlet(s) and
garage exhaust outlet (outlet location must meet WAC 51-52 501.2)
18) Contact Steve Fisher, Recycling Coordinator, at 425-771-0235 regarding dumpster enclosure
location and size.
19) Contact Linda McMurphy, Cross -connection Control Specialist, at 425-771-0235 regarding
premise isolation requirements to protect the public water system.