Loading...
21940 HWY 99 STE DSNOHOMtSH CO. 1'�'k --j FIRE PREVENTION Serving Brier, EurnonaY,'and 12425 Meridian Ave S D INSPECTION REPORT. 0 EDMONDS Mountlake Terrace Everett, WA 98208 0 BRIER Phone (425) 551-1200 0 MOUNTLAKE TERRACE UNINCORPORATED w4w.FireDistrictLorg Fax (425) 551-1272 FREQUENCY STATION& SHIFT LOCATION: 21940 Highway 99 Suite D 98026 Annual 20-C I Panda Express BUSINESS NAME: 6263728203 PHONE: SCHEDULED Aug 2017 DATE DUE MAILING LIFIR ADDRESS: 1683 Walnut Grove Ave, Rosemead, CA 91770 Pelagio, Daniel BUSINESS OWNER: HOME PHONE:LI-Z.5 1)to�'7 - Wong, Sulong EMERGENCY-1: HOME PHONE: 'CURRENT KEY ACCESS-2: 20 HOME PHONE: YES NO CITY BUSINESS F] EMAIL: LICENSE PERSON CONTACTED: 1-04-0A INITIAL INSPECTION DATE NAME OF INSPECTOR: i2-P�r" -'r, iADV--. I-- ', —7 -2-7 , 1-7 FIRE SYSTEMS: FE UL300 0 '0 7.1c �Isql) CITY OF EDMONDS 121 5TH A NENUE NORTH - EDMONDS, WA 98020 PHONE: (425) 771-0220 - FAX: (425) 771-0221 STATUS: ISSUED 11/15/2016 Pertwt#: BLD20161405 i BUILDING PERMIT I Expiration Date: 05/15/2017 Project Address: 21940 HIGHWAY 99 #D, EDMONDS Parcel No: 00580700004007 PANDA EXPRESS SANDERM N11 FIRE PROTECTION INC SANDERSON FIRE PROTECTION INC C/O X PROPERTIES LLC MGP C/O STEPHEN SPAHR CIO STEPHEN SPAHR 21840 HIGHWAY 99 #D 1101 SE 3RD AVE 1101 SE3RD AVE EDMONDS, WA 98026 PORTLAND, OR 97214 PORTLAND, OR 97214 (503) 889-3110 (503) 889-3 110 LICENSE # SANDEFP845DN EXP-03/15/2018 FIRE SUPPRESSION SYSTEM FOR TYPE I HOOD VALUATION: $0.00 PERMIT TYPE- Commercial PERMIT GROUP 80 - Fire Suppression GRADTNGr. N CYDS: 0 TYPE OF CONSTRUCTION: RETAINING WALL ROCKERY: OCCUPANT GROUP: OCCUPANT LOAD FENCE. 0 X 0 FT.) CODE. 2015 JOTHER: ------- OTHER DESC: IZONE: INUMBER OF STORIES 0 1 VESTED DATE: INUMBER OF DWELLING UNITS: 0 ILOT V rXISTINGAREA BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 PROPOSED ARLA IBASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 13 RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER- 0 13RD FLOOR: 0 GARAGE- 0 DECK- 0 OT HER 0 IBEDROOMS. 0 BATHROOMS: 0 IBEDROOMS: 0 BATHROOMS: 0 FRONT SETBACK SIDESE"FBACK REAR S LTBACK REQUIRED: PROPOSED- —7R—EQUIRED- PROPOSED- JREQUIRED- PROPOSED - HEIGHT ALLOWED.0 PROPOSED.0 IREQUIRED: PROPOSED: SETBACKNOTES: I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:2T �IS APPLICATION IS NOT A hEMIT UNTIL SIGNED BY THE -,BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. P- 9 Aignature Print Name Date Released By bate ATTENTION ITIS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL ORA CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBCI 09/ IBCI 10/ IRCI 10. APPLICANT ONLINE ASSESSOR OTHER STATUS: ISSUED BLD20161405 CONDITIONS • Final approval on a projector final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check the job card for all required City inspections including final project approval and final occupancy inspections. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. SoundNoise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00arn to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites /activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the issuance for this permit. Issuance ofthis permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. I INS PEMIONS THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT. SEE ECDC 19.00.005(A)(6) I PUBLIC WORKS (425) 771-0235 1 PR&TREATMENT (425) 672-5755 1 i�CL�JNG (425) 2754 01 1 When calling for an inspection please leaw the folio-Aing information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Prefereed, and mbether you prefer morning or afternoon. . F-Fire Suppression SystemAccept. SgP OCT 2 12016 DEVELC)PME14T SERVICES CTIR. CITY OF EDMONDS CITY OF EDMONDS BUILDING DEPARTMENT WORK ADDRFSS L OWNIF�-I, APPROVE ' i) 1),V! F- BLDG. PERN111- NUMBER V> \ - D Lz�-� � APPROVED FIRE DEPARTMENT SECTION IX -APPENDIX UL EX. 3470 ULQ GEY,747 F0,qQ �-1 10-1-OZ fiffy..5 S�STEM SELECTION GUIDE Note: System options do not cover all conceivable variations. They are listed here as a general guideline to show the most common type arrangemeh . t for multiple systems, Based on certain system designs utilizing manifolding, non-manifolding, 3-tank systems, etc., other tank/cartridge combinations can be designed. The combinations below are based on 11 flow, 3.0 gallon tanks and 5 flow, 1.5 gallon tanks. More competitive designs may be available by utilizing 12 flow and 6 flow systems when appropriate. T6tal Tank Type of I Carbon Dioxide Nitrogen Flow No.* Quantity System 1[ype of HardAare Cartr4dge,Required Cartridge Required 1-5 1 Single 1.5 Gal. Reg. Release 101-10 (423439) LT-20-R (42 . 3429) 6-11 1 Single 3.0 Gal. Reg. Release 101-20 (423441) LT-30-R (423435) 12-16 2 Double 1.5 Gal. Reg. Release 101-30 (423443) Double (423493) 3.0 Gil. Additional Tank 17-22 2 Double 3.0 Gal. Reg. Release 101-30 (423443)" Double (423493) 3.0 Gal. Additional Tank 23-33 3 Multiple 3.0 Gal. Reg. Release 101-20 (423441) LT-30-R (423435) 3.0 Gal. Reg. Actuator 101-30 (423443) ... LT-A-101-30 (423491) 3.0 Gal. Additional Tank 23-27 3 Multiple 11.5 Gal. Reg. Release 101-10 (423439) LT-20-R (423429) (Optional) 3.0 Gal. Reg. Actuator 101-30 (423443) ... LT-A-101-30 (423491) 3.0 Gal. Additional Tank 28-33 3 Multiple 3.0 Gal. Reg. Release N/A Double (423493) (Optional) (2) 3.0 Gal. Additional Tanks 34-38 4 Multiple 1.5 Gal. Reg. Release 101-10 (423439) LT-20-R (423435) 3.0 Gal. Reg. Actuator N/A LT-A-.101-30 (423491) Double 3.0 Gal. Tank Box 84-38 4 Multiple 1.5 Gal. Reg. Release 11011-31) l4ZJ44J) (Optional) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 101-30 (423443)... 3.0 Gal. Additional Tank 39-44 4 Multiple 3.0 Gal. Reg. Release 101-20 (423441) 3.0 gal. Reg. Actuator N/A Double 3.0 Gal. Tank Box 39-44 4 Multiple 3.0 Gal. Reg. Release 101-30 (423443)" (Optional) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 101-30 (423443)... 3.0 Gal. Additional Tank 45-49 5 Multiple 1.5 Gal. Reg. Release 101-30 (423443) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator N/A Double 3.0 Gal. Tank Box 45-49 5 Multiple 1.5 Gal. Reg. Release 101-10 (423439) ... (Optional) 3.0 Gal. Reg. Actuator 101-30 (423443) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 101-30 (423443) ... 3.0 Gal. Additional Tank Based on s flow numbers for a 1.5 gal. system and 11 flow numbers for a 3.0 gal. system. tanks are manifolded, only a 'double tank' nitrogen cartridge (Part No. 423493) can be used. :f , tanks are manlfolded. either an LT-A-101-30 nitrogen cartridge (Part No. 423491) or a double tank cartridge (Part No. 42349.3) can be used. Double (423493) LT-A-101-30 (423491) LT-30-R (423435) LT-A-101-30 (423491) Double (423493) LT-A-101-30 (423491) Double (423493) LT-A-101-30 (423491) LT-20-R (423429) LT-A-101-30 (4�3491) LT-A-101-30 (423491) 1"Uut-ml Cu R-102 RESTAURANT The ANSUL AUTOMAN Regulated Mechanical Release Assembly '3.0 gallon — Pa : rt No. 79�90 or 1.5 — Part No. 79291) con- FIRE SUPPRE I N gallon ains the regulated release mechanism, agent tank, expellant ANSUL gas iose tor agent tank hookup, and enclosure knockouts to facilitate SYSTEM nstalling actuation piping; expellant piping; detection system; and additional equipment. This regulated release assembly is used in (Standard UL 300 Listed) ;ingle, double, and multiple -tank systems and must be mounted to a rigid surface. The release mechanism can be used to intercon- iect both the actuation and expellant gas lines as required Nozzle Identification Chart )er system design. The fegulator is designed to allow a constant Nozzle Nozzle NOZZIb, 'low of gas into the tank at 110 psi (759 kPa) when the system is Nozzle Jy Part No. Stampin ELO" actuated. I W Nozzle 419336 1W n single, double, and multiple -tank systems, the provided expel - IWSS Nozzle 417333 1W ant gas hose connects the agent tank to the bottom outlet of the -egulator. In double and multiple -tank system configurations, the 1 IN Nozzle 419335 IN )ack outlet of the regulator is used as an expellant gas feed for 1 1 NSS Nozzle .417332 IN )ne additional tank-dnclosure or tank -bracket hookup. The enclo- 1/2N Nozzle 4`19334 1/2N 1/2 3ure contains the requi�dd knockouts to facilitate this connection. 3 J a pressure switch is to' be allached to the regulator, additional fit- 3N Nozzle 419338 3N Jngs are required. 2W Nozzle 419337 2W 2 The tank is mounted within the enclosure. The tank contains an 2WH Nozzle 78078 2WH 2 3daptor/tube assembly with a burst disc union. The burst disc ielps prevent siphoning of the agent up the pipe due to significant temperature fluctuations In the area where the tank is located. The 230' Nozzle 419339 230 2 tank is rhild steel and, under normal conditions, requires hydrosta- 245 Nozzle 419340 245 2 tic testing every twelve years. 2 The agent tank is shipped uncharged and must be filled with only 260 Nozzle 419341 260 2 ANSULEX Low pH Liquid Fire Suppressant during installation. 290 Nozzle 419342 290 The detection and additional equipment required per system 2120 Nozzle 419343 2120 2 design are connected to the release mechanism. The enclosure 1 F Nozzle 419333 IF 1 contains knockouts to facilitate detection and additional hookups. The system bad be actuated automatically or manually. Automatic actuation occurs when a fusible link within the detection system separates in a fire � condition. Manual actuation of the system occurs when personnel pull on the remote manual pull station pull ring., Total Tank Type of Nitrogen Carbon Dioxide Flow No.* Quantity System Jype of Ha;dware Cddridge Required Cartridge Reouired 1-5 1 Single 1.5 Gal. Reg. Release LT-20-R (7032) 101-10 (15850) 6-11 1 Single 3.0 Gal. Reg. Release LT-30-R (5373) 101-20 (17492) 12-16 2 Double 1.5 Gal. Reg. Release Double (73022) 101-30 (15851) 3.0 Gal. Additional Tank 17-22 .2 Double 3.0 Gal. Reg. Release Double (73022) 101-30 (15851)-- 3.0 Gal. Additional Tank 23-27 3 Multiple 1.5 Gal. Reg. Release LT-2(Y-R (7032) 101-10 (15850) 3.0 Gal. Reg. Actuator LT-A-101-30,(29187) 101-30 (15851)-" 3.0 Gal. Additional Tank ELECTRICAL SWITCHES The electrical switches are intended for use with electric gas - _1 WHC14 hr� valves alarms, coniactors, lights, contractor supplied electric power shut-off devices and other electrical devices that are.�I- C—AHAOSI, Fnio CTny5 0M. designed to shut off or turn on When the system Is actual d. 50MI ft(R SHUTS OFF Switches Eire available in kits: One Switch Kit, Part No. 4231378,1!'1 Two Switch Kit, Part No. 423879, Three Switch Kit, Part No.�1�'; fot,06�L Covar--r5) UNW-P-ROO-D 'S4UT-0VF- 423880, and Four Switch Kit, Part No. 42313811. Each switch has a set of single-oole, double -throw contacts rated at 21 amp, 1 HP, 125, 250, 277 VAt or 2 HP, 250, 277 VAC. Mounting hardware Is provided with each kit. cok4mol , N.C. 01 EXTINGUISHING AGENT ANSULEX Low pH Liquid Fire Suppressant (1.5 gaII6 n' — Part No. 79694 or 3.0 gallon — Part No. 79372) is a potassiur-h:based soi6 - tion designed for fast knock -down and suppression� of greas t related fires. The agent is shipped in plastic containe'r� which p�.o- vide one complete tank charge. Agent storage life e�pectancy! i , s twelve years. The distributor must record the batch nu'mbers and date of shipment receipt to be filed with each installati'on record.: SECTION IV — SYSTEM�DESIGN UL EX. 3470 ULC CEx747 Page 4-31 3-1-04 ' REV. t 11 Nozzle Application Chart (Continued) Minimum Maximum Hazard Nozzle Nozzle Haza�d . Dimensions Quantity Wood Fueled Char -Broiler Longest Side — 30 In. (76 cm) 1 14 — 40 in. Area — 720 sq. in. (36 — 102 cm) (4645 sq. cm) Upright Broiler Length — 32.5 in. (82.5 cm) 2 Width — 30 in. (76 cm) Salamander Length — 32.5 in. (82.5 cm) 2 — Broiler Width — 30 in. (76 cm) Wok 14 In. — 30 in. (36 — 76 cm) 1 35 — 45 in. Diameter (89 — 114 cm) 3.75 — 8.0 in. (9.5 — 20 cm) Deep 11 in. — 24 in. (28 — 61 cm) 30 — 40 in. Diameter (76 — 102 cm) 3.0 — 6.0 in. (8 — 15.2 cm) Deep Nozzle Tip Nozzle Part No. Stamping — Flow No. 419338 3N 419334 1/2N 419334 1/2N 419341 260 419335/417332 1 N/I NSS SECTION IV SYSttM DESIGN UL EX.. 3470 ULC 0EX747 Page 4-30 REV. 3 10-1-02 No7ile Applifiation Chart (Continued) Minimum Nozzle 1-ip Hazard Maximum Hazard Nozzle Nozzle Nozzle Stamping — Dimensions Quantoty Heights Part No. Flow No. Griddle Longest Side (High Proximity) 1 30 — 50 in. 419341 260 48 In. (122 cm) (76 — 127 cm) Area — 1440 sq. In. (perimeter (9290 sq. cm) located) Longest Side (High Proximity) 1 30 — 50 in. 419342 290 30 in. (76 cm) (76 — 127 cm) Area — 720 sq. in. (center located) (4645 sq. cm) Longest Side (High Proximity) 1 35 — 40 in. 419335/417332 1 N/1 NSS 36 in. (91 cm) (89 — 102 cm) Area — 1080 sq. In. (perimeter located) (6968 sq. cm) Longest Side 1 20 — 30 in. 419342 290 (Medium Proximity) (51 — 76 cm) 48 in. (122 cm) (perimeter Area — 1440 sq. in. located) (9290 sq. cm) Longest Side (Low Proximity) 1 10 — 20 in. 419343 2120 48 in. (122 cm) (25 — 51 cm) Area — 1440 sq. In. (perimeter (9290 sq. cm) located) Chain Broiler* Longest Side — 34 In. (86 cm) 2 10 — 26 In. 419336/417333 1W/1WSS (Overhead Protection) Area — 1088 sq. In. (25 — 66 cm) (7019 sq. cm) Chain Broiler Length — 43 in. (109 cm) 2 1 —3 in. 419335/417332 1 N/1 NSS (Horizontal Protection) Width — 31 in. (79 cm) (3 — 8 cm) Gas -Radiant Ch ar-Broller Longest Side — 36 in. (91 cm) 1 15 — 40 in. 419335/417332 1 N/1 NSS Area — 864 sq. in. (38 — 102 cm) (5574 sq. cm) Electric ChEir-Brbiler Longest Side — 34 In. (86 cm) 1 20 — 50 in. 419335/417332 1 N/I NSS Area — 680 sq. in. (51 — 127 cm) (4388 sq. cm) Lava -Rock Broiler Longest Side — 24 ln..(61 cm) 1 18 — 35 In. 419335/417332 1 N/1 NSS Area — 312 sq. in. (46 — 89 cm) (2013 sq. cm) Natural Charcoal Broiler Longest Side — 24 in. (61 cm) 1 18 — 40 in. 419335/417332 1 N/1 NSS Area — 288 sq. In. (46 — 102 cm) (1858 sq. cm) Lava -Flock or Natural Longest Side — 30 in. (76 cm) 14 — 40 in. 419338 3N Charcoal Chdr-Broiler Area — 720 sq. in. (36 — 102 cm) (4645 sq. cm) Minimum chain broiler exhaust opening — 12 In. x 12 In. (31 cm x 31 cm), and not less than 60% of Internal broiler size. SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEX747 Page 4-29 4.1-06 REV 5 Nozzle Application Chart (Continued) Minimum Nozzle 1p Maximum Hazard Nozzle Nozzle Nozzle Stamping — No. Hazard Dimensions - Quantity Heights P . art No. Flow Fryer (Non -Split Maximum Size Vat Only)* (with drip board) 21 in. (53 cm) x 14 in. (36 cm) (Fry Pot must not exceed 15 in. x 14 in. (38 cm x 36 cm)) High Proximity 27 — 47 in. 419339 230 Medium Proximity 20 — 27 in. 09340 245 Maximum Size (with drip board) 25 3/8 in. (64.4 cm) x 19 1/2 in. (49.5 cm) (Fry pot side must not exceed 19 1/2 in. (49.5 cm) x 19 in. (48.2 cm) High Proximity 21 — 34 in. 419338 3N Low Proximity 13 — 16 in. 419342 290 Maximum Size (with drip board) 18 In. (45.7 cm) x 27 3/4 in. (70.5 cm) High Proximity 25 — 35 In. 419338 3N (64-89 cm) Fryer (Split or Maximum Size N6n-SpIIt Vat) (with drip board) 14 in. (36 cm) x 21 In. (53 cm) 13 — 16 in. 419342 290 Low Proximity (33 — 41 cm) Fryer (Split or Maximum Size Non -Split Vat) (with drip board) 14 1/2 in. (37 cm) x 26 1/2 In. (67 cm) 16 — 27 in. 419342 290 Medium Proximity (41 — 69 cm) Range Longest Side 30 — 40 in. 419335 1 N 32 in. (81 cm) (76 — 102 cm) Area — 384 sq. In. (2477 sq. cm) Longest Side 40 — 48 in. 419333 1 F 28 in. (71 cm) (102 — 122 cm) Area — 336 sq - in. (With Backshelf) (2168 sq. cm) Longest Side (High Proximity) 40 — 50 in. 419340 �457:-. 28 in. (71 cm) (102 — 127 cm) Area — 672 sq. In. (4335 sq. cm) Longest Side (Medium Proximity) 30 — 40 in. 419341 260 32 In. (81 cm) (76 — 102 cr�) Area — 768 sq. in. (4955 sq. cm) Longest Side (Low Proximity) 2 15 — 20 in. 419342 290 36 in. (91 cm) (38 — 51 cm) Area — 1008 sq. in. (6503 sq. cm) For multiple nozzle protection of single Ityers, see detailed Information on Pages 4-7 through 4-11. SECTION�W­, SYSTtM DIESIGN I UL EX. 34*: ' ULC CEx!47 Page 4-28 REV. 6 1 4�1-06 i . Nozzle Ap*pllb�tlon Chart The following bfiart has been developed to assl§t In calculating the quantity and type of nozzle required to protect each duct, plenum, or appliance. N0710E This'. dhart Is for general reference only. See complete details for each typo of hazard. Minimum Maximum Hazard Nozzle Hazard, Dimensions Quantity Duct or Transition Length — Unlimited (Single Nozzle) Perimeter — 50 In. (127 cm) Diameter — 16 In. (40.6 cm) Duct or Tra.hsi flon Length — Unliml ted (Single Noizlb)' Perimeter — 100 In. (254 cm) Diameter — 31 7/8 In. (61 cm) Duct or Transition Length — Unlimited 2 (Dual Nozzle) Perimeter — 150 In. (381 cm) Diameter — 48 in. (122 cm) Electrostatic Pr6cipitator Individual Cell 1 (At Base of Duct) Plenurn Length — 1 Oft. (3.1 m) (HorizoIntal Protection) Plendr-h Length — 6 ft. (1.8 m) (Horizontal Protection) Width — 4 ft. (1.2 m) Plenum Length — 4 ft. (1.2 m) (Vertical Protection) Width — 4 ft. (1.2 m) Fryer (Split or Maximum Size Non -Split Vat) (without drip board) 14 In. (36 cm) x 15 In. (38 cm) Low Proximity Fryer.(Spiii or Maximum Size Non-Solit Vat) (without drip board) 14 1/2 In. (37 cm) x 14 In. (36 cm) Medium Proximity Fryee,(Split or Maximum Size Non -Split Vat)* (without drip board) 16 In. (38 cm) x 14 In. (36 cm) High Proximity Medium Proximity Fryer (Non�-Split Vat Only) Maximum Size (without drip board) 19 1/2 In. (49.5 cm) x 19 In. (48.2 cm) High Proximity Low Proximity Maximum Size (without drip board) 18 In. (45.7 cm) x 18 In. (45.7 cm) High Proximity Nozzle Tip Nozzle Nozzle Stamping Heights Part No. Flgyv No. 430912 1W 419337 2W 419337 2W 419334 1/2N 419335 1 N 430192 1W 419336 1W 419336 1W 13 — 16 in. 419342 290 (33 — 41 cm) 16 — 21 In. 419342 290 (41 — 69 cm) 27 — 47 in. 419339 230 20 — 27 In. 419340 245 21 — 34 In. 419338 3N 13 — 16 In. 419342 290 25 — 35 In. 419338 3N (64-89 cm) * For multiple nozzle Orolectlon 61 tingle fryers, -see detalled Information on Pages 4-12 through 4-14 Fire System Parts List Job # 2655269 -. Panda Express 2757 - Edmonds WA (S4- Location: EDMONDS, WA 16-D4626) Fire System #1 Ansul R102 ANSUL-3.0/3.0/3.0-WC Tag: . InstalledNall Mount Left Hood #1 Hoods Covered: Hood # 1 Hood # 2 Gas Valve(s):Mechanical 2.000" Supplied by Captive Aire Systems Ship with Hood Supplied by Ship QtyltemCAS # Vendor# Description Dist CAS Units Insti-oose 4 36 PE -HT PE -HT PULLEY ELBOW - High Temp Pulley Elbow, 0 4 EACH --------- -�E- --------- Compression Type 13 PE- Ei F�6 L_L_�Y :;W r; -------- EB61�i - C f� 1� P u Iley E ii�c;�'_ �it _�c_r`ew'7 1_0 --- CH ---------- -------------------------------------------------------------------------- Type ANSUL Part #415670 1 34 RPS-A RPS-A — REMOTE PULL STATION - Red composite (without wire ---------------------- 0 1 EACH ---- --- rope) 434618 (Old Macola #06-4835) 7 _�66FL �W6_�66FL 1- ---- --- --------- --- FGS�KE LINK-- Y66jj6 F, _�-102`and 'PIRANHA, -Part--- _0__' 7 - EACH ------- Number 439232 3 - ------- _i6.ANS-360FL ---- ---------- ANS-360FL --- -------- --------------- -- -- --------- -- FUSIBLE - LIN K - 360deg F, - R-1 - 02 - and PIRAN - HA ------- _. 0 ­ 3 __ EACH -------- --- 10 --------------------------------------------------------------------------------- 28 S-DET S-DET — DETECTOR - Series (Scissor Linkage) ---------------------- 0 10 EACH _ii. ---- NEW#435547/435548 (OLD#417369/434480) ------------- 5 QF6� -1 ii -1/2 ---------- -------- PULLEY SEAL - 1/2" Hood Seal (UL) 0 5 EACH 15 ------- 6i�i doik_ SEKC - i/8" ( uc� ------------ 0 15 - EACH -------- .- 5 - ------ i6. 418569 -------- ---- �i3572 ------ — ---------------- ------------ ----------------- N - OZZLE ADAPTOR Swivel Nozzle - Adaptor (Replaces 0 5 - . EACH -------- ------- CAS Part # 418569)AO001274 4 24419341 439i44 W6iiCg - 260 Nozzle, Appliance (Replaces ANSUL 0 4 EACH ----- ---------------------------------------------------------------------- Part# 419352, CAS Part# 419341) A0001 271 — ---------------------- 3 19339 439842 NOZZLE - 230 Nozzle, Appliance (Replaces ANSUL 0 3 EACH ----- ------------------------------------------------------------------------------- Part# 419350, CAS Part# 419339) A0001 269 6 1'6 419335 439838 NOZZLE - 1 N Nozzle, Plenum/Applianoe (Replaces — ---------------------- 0 6 EACH ----- ------------------------------------------------------------------------------- ANSUL Part# 419346, CAS Part# 419335) A0001265 2 13419337 439840 NOZZLE - 2W Nozzle, Duct (Replaces ANSUL Part# — ---------------------- 0 2 EACH ----- ------------------------------------------------------------------------------- 419348, CAS Part# 419337) A0001 267 2 12 HOSE 79007 HOSE - Rubber Hose — ---------------------- 0 2 EACH ----- 1 ------------------------------------------------------------------------------- 11 MICRO-SDA MICRO-SDA MICROSWITCH KIT- Includes 2 switcvhes and Mounting 0 1 EACH Hardware. Single Dual Electric Switch, One Standard ----- ------------------------------------------------------------------------------- Switch, One Alarm Duty Switch 437155 ----------------------- 1 10 TLINK TLINK LINK - Test Link (1 test link) 1 0 EACH ------------------------------------------------------------------------------------- 1 9 DT-CART 73022 Double Tank Nitrogen Cartridge : — ---------------------- 1 0 EACH ­�__­66_i ---------- 5 0 ii ----------- 372 W ----- -------- 6 EK� 1_4 --- ------------------- nsulex Low PH Wet Chemical Agent, 3 Gallon 3 0 EACH (UL)79372 3- Wd-b 6� Wi--6 E_ M �E66EKfg --- Ec�'W�g - -------------------------- ii D R - Ansul Regulated Mechanical 0 1 EACH Release/Bracket Assembly (79493), OEM, R-1 02, ------- Cartridge Detection Included - - ------------ - — ---------------------- 1 -3 ------------------------- fi� W (#11 - 3.0 Gallon S Tank (for use with Automan i) 9 0 3 EACH ------------------------------------------------------------------------ Release, Actuator, or SS Enclosure (UUULC)) 15 0 LCAP-CBMETALCAP-CBBLOWOFF CAP - Metal — ---------------------- 0 15 EACH ----------- 1 ii --------- 0 43- 733 Z _ig -------- - 733 W _Ky _4� - ------------------------------- lwz�yl_ �li dEMBLY - Air Cylinder and Tubing — ---------------------- 0 1 EACH ----------------------------------- for Mechanical - Gas -Valves (Ansul) ------------------- — ------------------ * wL_ 9.102- 5 Q�-L� U L-300 Job Napkeo Panda Express 2757 - Ednot. s WA - 2655269 Bv S'yst'em rl..- ANSUL-3.0/3.0/34-WC Hood * I IL6W Lang x 48' Wide x 24' High Riser # I S el 12' x 6' Hood # I Me -to[ Biow-Off Cas irctuded. Hood # 2 111 6.001 Lr? x Wide x 24' High Riser # I Streo 12' x 6' Hood * 2 Metat Blow -Off Caps included. 0 Kz::7 K::::) �� 735 FIRE COPY NOTES 9)15 1* SwKje- I ga's CA 4,0 - FIELD PIPE DROPS AS SHOWN - SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS - RELOCATE NOZZLES IT FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - MAXIMUM 9 ELBOWS IN SUPPLY LINE, MINIMUM 72 INCHES OF AGENT LINE FR13M TANK TO FIRST NOZZLE. IF APPLICABLE, PRE -PIPED CHARBROILER DR13PS ARE SHIPPED LOOSE. FACTORY PIPING EXTENDS A MAXIMUM OF 6' ABOVE THE TOP OF THE HOOD, APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. TIHIS FIRE SYSTEM CM%041ES WITH U.L. 300 REQUIREMENTS v w 4--1 _J 5 it 11 i - I . ' - - a . f.a. a b v -4 OCT 2 12016 DEVEWPMENT SERVICES CTR. CIlY OF EDMONDS r