22401 98TH AVE W.PDFlill 11111111
9703
22401 98TH AVE W
SOUTH FORK GEOSCIENCES, PLLC
PO Box 1275
NORTH BEND, WA 98045
(425) 831-2023
ANDREWeSFGEO.COM
VREET FILE
December 3, 2015
Project #15062
The Leren Company Inc. DEC 2 8 2015
PO Box 12863
Mill Creek, WA 98082 BUILDING DEpARWENT
GM of EDMONDS
Attention: Mr. Tom Leren
Subject: Additional Supplemental Information
Soil Assessment for Stormwater Infiltration/Low Impact Development
BMP Simplified Sizing
Proposed Addition — Strayer Residence
Parcel #00450701200007
2240198"' Avenue West, Edmonds, WA 98020
Mr. Leren:
The purpose of this letter is to provide some additional clarification with respect to our previous
work on the project, which was documented in the referenced letter (South Fork Geosciences,
August 11, 2015). It is our understanding that through the course of the project design, the
stormwater flow control measures for the proposed addition were changed from an infiltration
drywell to a "rain garden" type of facility. This proposed rain garden will be constructed
approximately 25 to 30 feet north of our previous soil exploration. Based on our phone
discussions and e-mail correspondence with Mr. Leren and Mr. Jeff Haynes, PE (CSP
Engineering), it is our understanding that City of Edmonds staff has requested additional soils
information for the new location.
Based on our previous site reconnaissance, we observed native Vashon lodgement till soils on
the subject property. Due to the relatively flat topography, and how the grades on the property
compared to adjacent properties and streets, we did not observe any signs of significant fill soils.
Based on these observations, the nearby location of our previous exploration, and in combination
with our knowledge of the regional geologic setting, it is our opinion that our previous work that
was documented in the referenced letter suitably characterizes the shallow subsurface soils with
respect to infiltration in the new rain garden location.
Though we mentioned this in our previous letter, the roof runoff currently generated by the site
discharges from downspouts directly onto the ground surface. This would be considered a
substandard stormwater best management practice by current standards, yet this has been
performing without observed problems or impacts since the home was constructed. It stands to
reason that similarly sized drainage areas routed to modern best management practices such as
rain gardens or infiltration facilities will function properly upon construction.
SOUTH FORK GEOSCIENCES, PO Box 1275, NORTH BEND, WA 98045,(425) 831-2023
Closure
We have enjoyed working with you on this project and are confident that the information provided in
this letter will aid in the design of your project. If there are any questions about this letter, please
feel free to contact us.
Sincerely,
Andrew L. Glandon, LEG, CPESC
Geologist / Owner
South Fork Geosciences, PLLC
References:
"Soil Assessment for Stormwater Infiltration/Low Impact Development, BN1P Simplified Sizing, Proposed Addition — Strayer
Residence, Parcel #00450701200007, 2240198' Avenue West, Edmonds, WA 98020", South Fork Geosciences, PLLC, August
11,2015
2
SOUTH FORK GEOSCIENCES, PO Box 1275, NORTH BEND, WA 98045,(425) 831-2023
a7t!�) t��- - 0 & 07
SOUTH FORK GEOSCIENCES, PLLC
PO Box 1275
NORTH BEND, WA 98045
(425) 831-2023
AGLANDON@COMCAST.NE'r
The Leren Company Inc.
PO Box 12863
Mill Creek, WA 98082
Attention: Mr. Tom Leren
August 11, 2015
Project #15062
L
�43
SEP 18 2015
BUILDYIN,G DEPARTMENT
aT DF EDMONDS
Subject: Soil Assessment for Stormwater Infiltration/Low Impact Development
BMP Simplified Sizing
Proposed Addition — Strayer Residence
Parcel #00450701200007
2240198' Avenue West, Edmonds, WA 98020
Mr. Leren:
The purpose of this letter is to summarize our assessment of the onsite soils for stormwater
infiltration. Based on our phone discussions and e-mail correspondence, it is our understanding
that the City of Edmonds uses the referenced document (#E72B) for Low Impact Development
Best Management Practices (LID BMP) facility sizing. Based on our review of this document,
the sizing for these facilities can be determined by using the USDA soil textural classification of
the receptor soil, in accordance with the long-term infiltration rates set forth in the 2005 DOE
Stormwater Management for Western Washington (2005 DOE Manual). The following sections
will briefly describe the property, the shallow subsurface conditions, and our conclusions with
respect to LID BMP sizing.
Site Description
The property was located at 22401 98h Avenue West in Edmonds, Washington. According to
the King County Assessor Records, the property was 8,400 square feet (0. 19 acres) in size.
There was an existing single family residence and garage on the property, with associated
landscaping and grading for the driveway and yard areas. The property was flat to very gently
sloping and we estimate that the total relief on the property was on the order of 3 feet. The
property was bordered by 224th Street SW to the north, 98th Avenue West to the west, and by
residential properties to the south and east.
1
SOUTH FORK GEOSCIENCES, PO Box 1275, NORTH BEND, WA 98045,(425) 831-2023
Subsurface Conditions
Subsurface conditions on the property were inferred from a visual reconnaissance of the property, a
review of the referenced geologic map (Minard, 1983), and one hand auger boring. The hand auger
boring was logged by the undersigned licensed engineering geologist. The location of the hand
auger boring is shown in the attached Site and Exploration Plan and the log are attached to this
report. Our interpretation of the near surface, native soils as Vashon lodgement till sediments is in
agreement with the referenced geologic map.
Stratigraphy
Vashon Lodgement Till
Based on our hand auger boring, our review of the referenced geologic map, and our knowledge of
the area, we interpret the near surface native soils on the subject property as Vashon lodgement till
sediments. Lodgement till sediments are a dense, poorly sorted mixture of clay, silt, sand, and
gravel that was deposited at the sole of the Vashon glacial ice. These sediments typically possess
high strength, low permeability, and low compressibility characteristics as a result of consolidation
from being overridden by several thousand feet of glacial ice. Vashon lodgement till sediments, due
to their glacially consolidated nature, are relatively dense in place and erosion resistant.
Hydrology
There was no groundwater seepage observed or signs of past high groundwater table such as
mottling or oxidation observed in the hand auger boring. Though groundwater conditions are
subject to change seasonally, based on the sediments observed and the geologic setting it is our
opinion that the likelihood of a static groundwater table at less than 8 feet below the ground
surface is extremely low.
USDA Soil Textural Classification
A sample of the soil from the depth interval from 2 to 2.5 feet was obtained from the hand auger
boring for laboratory testing. A sieve analysis with hydrometer was performed on the sample.
The results of this grain size analysis is attached to this report. After normalizing the
percentages for the material passing the #4 sieve (fine gravel/coarse sand threshold), the USDA
Soil Texture Triangle classification was determined to be "sandy loam", as shown in the USDA
Soil Textural Classification attachment.
LIB BMIP Sizing
As previously stated, we determined that the receptor soil is classified as a "sandy loam" using
the USDA Textural Classification. In Table 3.7 "Recommended Infiltration Rates
based on USDA Soil Textural Classification" in Volume III of the 2005 DOE Manual, the
Estimated Long -Term (Design) Infiltration Rate for a "sandy loam" is 0.25 inches per hour.
2
SOUTH FORK GEOSCIENCES, PO Box 1275, NORTH BEND, WA 98045,(425) 831-2023
Observations of Eidstinix Downspouts
During our site reconnaissance, we observed the gutter downspouts on the existing home. These
downspout pipes were routed directly to the ground surfacewithout any splash pad or dispersion -
type BMP in place. We did not observe signs of significant surface flow or erosion from these
downspout locations. Since the subject property is relatively flat and there are no signs of
significant surface flow or erosion associated with the existing downspouts, it is our opinion that
the roof runoff from the proposed addition could be dispersed using splash pads, as long as the
impervious surface drained per each new downspout is similarly sized to that of the existing
house. It is our opinion that this alternative would be functionally equivalent to drywells or
infiltration trenches and based on the historical performance of the exiting downspouts, it would
not adversely affect the subject or adjacent properties.
Closure
We have enjoyed working with you on this project and are confident that the information provided in
this letter will aid in the design of your project. If there are any questions about this letter, please
feel free to contact us.
Sincerely,
Andrew L. Glandon, LEG, CPESC
Geologist / Owner
South Fork Geosciences, PLLC
Attachments: Vicinity Map
Site and Exploration Plan
Hand Auger Boring Logs
Grain Size Analysis
USDA Soil Textural Classification
References:
"City of Edmonds Development Information, Low Impact Development (LID) Stormwater Best Management Practices (BMPs)
Simplified Sizing" #E72B
"Geologic Map of the Edmonds East and Part of the Edmonds West Quadrangles, Washington", Minard, James P., 1983, United
States Geological Survey, Miscellaneous Field Studies, Map MF-1541, Scale 1:24,000
. 3
SOUTH FORK GEOSCIENCES, PO Box 1275, NORTH BEND, WA 98045,(425) 831-2023
Not to Scale
f 4
Site
Pr
_q.
&IDIOM
Vicinity Map
Strayer Residence Addition, 22401 98 1h Avenue West, Edmonds, WA Project #15062
Site Plan
SCALE: ["=20.00'
0. 10' 20' 50' 40' 50'
Site Address
22401 q&TH AVE KEST
EDMON05, KA qb02O
Owner
Compost Soil Note
ALL OISTUR5ED SOILS 5KALL W
=
CAOMPOST AMENDED PER BW TS.15
Or THE STOR141LATER RANUAL.
ii,
60'
Cut and Fill
—
CJJT, 60 YOS.
FILL� 20 YDS. (APPRO>O
Height Calculations
A 102.15
IS 105.5
1045
1045
AVERAGe 105.D2'
MAX HEIew: 12bb2'
ACTUAL RIP615 KT. 125,152'
EASTINS MAIN FLOOR� 106.001
DP. AT SEIAER MR. IN ROAD
SET 0 100,00,
MELINDA 4 TIMOTHY STRAYER
22401 q&TH AVE NEST
EDMONDS, KA c15020 Filter Socks Slit Fence
FILTER SOCKS PER CITY OF SIL FENCES AS INDIOATED ON 51TE
Assessoes Parcel No. EDMONDS STANPARD DETAIL E1.5. PLAN PER CITY OF EDMONDS
00450`70Q�M STANDARD DETAIL EI.I.
Conventional SWM T
Stockpile
AS INDICATED ON SITE PLAN. F)CATIWr, GFV4rQ MH
Excess Material - Excavation
TO BE USED AROUND PERIMETER AND AS PILL.
Drainaue
NIEN IMPERVIOUS UNDER 2000 5F TO BE
HITH 5PLA5HELOCK5. AREA OVER 2000
TO BE INFILTRATED IN 4' VIA. x 60"
INFILTRATION PIT PER 5117E PLAN.
Erosion Control
EX15TINC, LANDSCAPE TO REMAIN. AREA OF
DISTURBANCE TO BE COVERED WITH 5TR.AA AND
SILT FENCE PERIMETER.
Lot Size
&400 50. FT.
Building Footprint
HOUSE (EXISTINS.) c04 50. FT.
NEH ADDITION 1245
TOTAL 50 1 F T. 22211
LOT COVERArDE 26.5%
F09N,
e and Exploration Plan
il Assessment for Stormwater Infiltration
aver Residence Addition
-J L- — — —
— — — — — — — -
—LAHNr
EASTINC7
"S— "S— "S w
RE4loENCE
Imnervious surface calca
Type
Area (sq. ft.)
1
Non -regulated
2§49
Exarnpl
jm�empt
2
'Replaced
754
3
New (P��1977)
1615
4
Total Regula6kimpe-1-d- Area
MidgatIon mqked If In alqmq� al
2369
5
Total area mIdg3A"xIstIng
storm.tr managementsystem.
2000
6
Regula��rea not yet m1fil d.
369
7
Ares,proposed to be mitigated by
)Zw'mpa ct Development Tech.
Z7
Area proposed to be mitigated by
echniques.
' NEK DRVEMY
'E" 'VE'1AY
5
'!Z
Emo Exi5T
X
5TOCKPIL
I
,-SILT
PENCE
... ....... .. . k
M.
3
�;OROI`05EV
ADDITION
Ali
10 'DIA
x 60" DEEP
- INFILTRATION
I PIT K/ CRUSHED
I ROCK
---- -- ----------
1 0.00 X15 11116 PATIO Tj BE REMOVED
SILT
111111-M
Strayer Residence Addition
Edmonds, WA
Date: 7-30-2015
Depth Number: HB-1
(it)
0 Sod/Topsoil (0-2")
Vashon Lodgement Till
loose to medium dense, dry, light brown silty
fine SAND with gravel (SM)
1 - roots present to 1.5ft
2 d Idense, dry to damp, light gray silty fine SAND
with gravel (SM)
Total Depth = 2-5ft
Refusal due to density
3 No groundwater seepage observed
No caving observed
Sample taken @ 2-2.5ft for grain size analysis
2
5
2
7
Hand Auger
Boring Log
IThe subsurface conditions shown on this field log represent our observations at the time and location of excavation, twdified by geologic intetpretation and
judgment, and where noted, by engineering analysis and laboratory testing. The conditions shown may not be representative of conditions at other tirms.
South Fork Geosciences will not be responsible for use or intetprelation by others of inforrnation presented on these logs.
Project # 15062
SouTH FoRK GEOSCIENCES
PO Box 1275
NORTH BEND, WA 98045
PHONE: (425) 831-2023
10C
9C
8C
70
Particle Size Distribution Report
d . ..e 0 0 0
d 6 6 S G co 0 C�
-It M- V a 8 �! ;! C,
U :11 * :2, 9
TEST RESULTS
Opening
Percent
Spec.*
Pass?
Size
Finer
(Percent)
(X=Fail)
2
100.0
1
82.0
3/4
78.0
3/8
67.0
#4
62.0
#10
56.0
#40
47.0
#60
40.0
#100
31.0
#200
22.8
#270
18.9
#325
17.3
0.0344 turn.
13.6
0.0222 nun.
11.8
0.0131 mm.
9.3
0.0094 mm.
8.0
0.0067 nun.
6.8
0.0048 mm*
5.6
0.0033 mm.
4.9
Material- Description
Lt. Grey silty sand with gravel
Afterberg Limits (ASTM D 4318)
PL= NP LL= NV PI= NV
Classification
USCS (D 2487)= SM AASHTO (M 145)= A- I -b
Coefficients
D,O: 01114117 D,5= 019.60079 D60 3:053146
D50 .61 5 D3 = .14 2 D IS: 0 82
D10= 0.0151 cu� 232.41 Cc= 0.37
Remarks
Equipment: 53, 66, 58, 141
Date Received: 7/30/2015 Date Tested: 8/5/2015
Tested By: J. Hoover
Checked By: Mike Blackwell
Title: Laboratory Manager
. (no specification provided)
Source of Sample: Strayer Residence #15063 Depth: 2'- 2.5' Date Sampled: 7/30/2015
Samale Numbdr: HB-I -
A.A.R. Client: So. Fork Geosciences
Testing Project: Misc. Lab
Laborato!y, Inc. Proig-d NP: 15-103 Figure -- 15-165
too
RLAAMAMAII
M
MWA
INX
I
ZWA 0
0, -00 10, '0 `b
4 Sande'7,
USDA Soil Textural Classification
Strayer kesidence Addition, 22401 98 th Avenue West, Edmonds, WA Project #15062
PLANNING DATA
SINGLE FAMILY RESIDENTIAL
:F[L:E:]
Name:
Date: tz, t(
Site Address:
Plan Check #:
Project Description:
Reduced Site Plan Provided: (YES /)10)
Zoning:
Map Page: --------- —".
Corner LoVJ5R NO)
Flag Lot: (YES /QEOD
Critical Areas Determination #:
El Study Required U4-141=
M—Waiver
SEPA Determination:
Exempt
Needed (for over 500 cubic yards of grading)
0 Fee 0 Checklist 0 APO List with notarized form
Required Setback5 ('10
St t:
Sid
Sid. -
Actual Setback5
Street:
S t7d e:
Detached Structures:
Rockeries:
Fences/Trellises:
El Bay Windows/ Projecting Modulation:
El Stairs/Deck:
Height
Datum Point: 4\
Datum Elevation:
Maximum Height Allowed:
Actual Height: ZJ7 -F
Other
Parking Required: 2-
Parking Provided: e.-I d.,,c -7-0
Lot Area: S t'Ll 0 C9
Maximum Lot Coverage: 35% Proposed: 7
Lot Coverage Calculations: I-ILI V /11S
ADU Created: (YES
Subdivision: k.JV,1-4"u-C, Vonles+e0fd AtY-
Legal Nonconforming Land Use Determination Issued: (YES / NO)
LLig 14 Comments
10
lo 3 .5- Z_57 -- t 2, V 0070 -Z a,4
CP-fqrLK1U re
/Gy.
Pla n Review By: A
&A
6*�
I ,
wte�)(Pv- //) �-Arrl-
Planning Data Form 04-11-06.doc
Site Plan
50ALE: I"=20.00'
01 101 20, 501 4o' 5o' bol
Site Address
22401 cWH AVE 1-*,E5T
EDMONDS, KA c15020
Owner
MELINDA 4 TIMOTHY STRAYER
22401 41bTH AVE NEST
EDMONDS, KA 11b02O
AssessoesParcel No.
00450-10120000-1
Stockpile
AS INDICATED ON SITE PLAN.
Excess Material - Excavation
TO BE USED AROUND PERIMETER AND AS FILL.
Drainage
PER CIVIL PLAN (BY OTHERS)
Erosion Control
EX15TIN6 LANDSCAPE TO REMAIN. AREA OF
DISTURBANCE TO BE COVERED NITH STRAIN AND
SILT FENCE PERIMETER.
Lot Size
5400 50. FT.
Building Footprint
HOUSE (r=X15TINC7 Wilt Icl:299 cl&4 50. FT.
NEN ADDITION 1245
TOTAL 50. FT. 222cl
LOT COVERA&E 26.5%
Compost Soil Note
ALL P15TUREWD SOILS SHALL 5E
COMPOST AMENDED FER 5MF T5.15
OF THE STORMKATER MANUAL.
Cut and Fill
CUT: bo Ylrm.
FILL: 20 YDS. (APPROX)
Height
Calculations
A
102.15
B
1055
0
1045
0
1045
AVERASE 10�.621
MAX �EIOW-- 126.62,
ACTUAL RIVC7E HT. 125,D2'
EXISTIN6 MAIN FLOOR: 106.00,
D.P. AT SE)AIER M.H. IN ROAD
SET a 100.00'
Filter Socks Silt Fence
FILTER SOCKS PER CITY OF SILT FENCES AS INDICATED ON SITE
EDMONDS STANDARD DETAIL EI.5. PLAN PER CITY OF EDMONDS
STANDARD DETAIL EI.I.
EX15TINO SENER M.H.
DATV POINT @ 100.00-
Appll�,nt sha� rep&/
0�' ftn�age hpnovz��Qn'iz-' U�v
r a
pr Ci,,,y StEg;�eF-
or occurt, durlig
0WHER/CONTFUCT0.9 IS RESPONSIBLE FOR
P � 0-Q! ON TR C-'- .4 PTI D P2,! � -16. r�- -��
224TH ST. S.H.
Zone J��-F Comer Fla& —
Setback Reauired Actual 4,- a10.-\
Front,v/vj -i-67-77g-
SidesF/� 2- 7-
Rear
Other
ENGNEF-RiNG DIVL90N
AIr ED AS NOTEQ
Date.J1926(0
0%44516 AvbO Sox Ct, F09-
fAW(pNtV6IkJ O6-S-1CQU 0111LIFAM-So.
ASPHALT DRIVE IN R.O.A.
(SEE CIVIL)
4---RAIN OARVEN
11 PER CIVIL
NCE
0*129
H III
E
e L-b 2D(�-060�
BUILDING DEPARTMENT
CITY OF EDMONDS
STORMWATER MANAGEMENT PLAN
"M
...........
GENERAL SPECIFICA71ONS
ALL MATERIALS, WORK, AND CONSTRUCTION WORKMANSHIP SHOWN ON THESE PLANS SHALL CONFORM TO THE APPROVED
STANDARD PLANS AND SPECIFICATIONS OF THE LOCAL GOVERNING AUTHORITY. EXCEPT WERE ADOPTED LOCAL STANDARDS
PROVIDE OTHERWISE, ALL MATERIALS, WORK, AND CONSTRUCTION WORKMANSHIP SHOWN ON THESE PLANS SHALL ALSO
CONFORM TO THE CURRENT EDITIONS OF THE FOLLOWING SPECIFICATIONS AND CODES, AND ALL OTHER APPLICABLE LOCAL
MUNICIPAL, STATE, AND FEDERAL CODES, RULES AND REGULATIONS.
-INTERNATIONAL BUILDING CODE
-WSDOT/APWA STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION
-WASHINGTON STATE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR WESTERN WASHINGTON
THE ABOVE REFERENCED DOCUMENTS SHALL BE CONSIDERED AS INCORPORATED INTO THIS PLAN SET BY REFERENCE. SELECTED
STANDARD DETAILS AND NOTES FROM THE ABOVE REFERENCED DOCUMENTS ARE ILLUSTRATED ON THESE PLANS TO FACILITATE
CONSTRUCTION OF THIS PROJECT HOWEVER NOT ALL OF THE INFORMATION REFERENCED ABOVE IS INCLUDED. THE CONTRACTOR
IS RESPONSIBLE FOR OBTAINING COPIES OF THE ABOVE REFERENCED DOCUMENTS AND COMPLYING WITH THE SPECIFICATIONS
AND STANDARD DETAILS IDENTIFIED THEREIN.
PERMITS
1. THE CON TRACTOR/DEVELOPER/OWNER SHALL BE SOLELY RESPONSIBLE FOR OBTAINING ALL NECESSARY LOCAL, STATE, AND
FEDERAL PERMITS NECESSARY FOR THE IMPLEMENTA71ON OF THE PROJECT ILLUSTRATED ON THESE PLANS.
AS -BUILT RECORDS
1. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOBSITE WHENEVER CONSTRUCTION IS IN PROGRESS.
2. DEVIATIONS FROM THESE PLANS MUST BE APPROVED BY THE ENGINEER OF RECORD AND THE LOCAL GOVERNING AUTHORITY.
3. THE CONTRACTOR SHALL RECORD ALL DEVIA71ONS FROM THESE PLANS ON A SET OF "AS -BUILT" DRAWINGS AND SHALL
SUMMARIZE ALL AS -BUILT CONDITIONS ON ONE SET OF REPRODUCIBLE DRAWINGS FOR SUBMITTAL TO THE APPROPRIATE
PERMITTING AGENCIES PRIOR TO PROJECT COMPLETION AND ACCEPTANCE.
SURVEY INFORMATION / EXISTING U71LITIES AND SITE FEATURES
1. LEGAL DESCRIPTION, VERTICAL DATUM, BASIS OF BEARING, BENCHMARKS & MONUMENT TIES ILLUSTRATED ON THESE PLANS
HAVE BEEN PROVIDED BY OTHERS OR OBTAINED FROM ONLINE, DESIGN, ANDIOR AS -BUILT RECORDS.
2. THE LOCATIONS OF EXISTING UTILITIES AND SITE FEATURES ILLUSTRATED ON THESE PLANS HAVE BEEN PROVIDED BY OTHERS
BY FIELD SURVEY OR OBTAINED FROM ONLINE, DESIGN, ANDIOR AS -BUILT RECORDS AND SHOULD THEREFORE BE CONSIDERED
APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE.
3. CSP ENGINEERING ASSUMES NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF INFORMATION ILLUSTRATED ON
THESE DRAWINGS WHICH HAS BEEN PROVIDED BY OTHERS OR OBTAINED FROM OTHER SOURCES.
4. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS
ILLUSTRATED ON THESE PLANS AND TO FURTHER DISCOVER AND PROTECT ANY OTHER UTILITIES NOT SHOWN HEREON WHICH
MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN.
5. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL CONDITIONS AND DIMENSIONS AT THE PROJECT SITE, INCLUDING THE
LOCATION, DEPTH, SIZE, TYPE, CONDITION, AND CONFIGURATION OF EXISTING UTILITIES AT CONNECTION OR CROSSING POINTS,
BEFORE TRENCHING FOR NEW UTILITIES, CONSTRUC71NG ANY SITE FEATURES, OR ORDERING ANY PRECASTIPREFABRICATED ITEMS
ASSOCIATED WITH THE IMPLEMENTATION OF THIS PROJECT.
6. THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE AND CSP ENGINEERING OF ANY DISCREPANCIES FOUND IN
THE FIELD WHICH MAY AFFECT THE IMPLEMENTATION OF THIS PROJECT.
7. CONTRACTOR SHALL PROTECT ALL UTILITIES DURING CONSTRUCTION AND SHALL CONTACT THE UNDERGROUND UTILITIES
LOCATION SERVICE (1-800-424-5555) AT LEAST TWO (2) BUSINESS DAYS PRIOR TO CONSTRUCTION.
SHOP DRAWINGS / REQUESTS FOR INFORMAT10N / FIELD REVISIONS
1. SHOP DRAWINGS FOR ALL PRECAST ANDIOR PREFABRICATED ITEMS, CAST -IN -PLACE DRAINAGE STRUCTURES, AND GENERIC
ITEMS (I.E. YARD DRAINS) SHALL BE SUBMITTED TO CSP ENGINEERING FOR REVIEW PRIOR TO FABRICATION, INSTALLATION,
ANDIOR DELIVERY TO THE SITE.
2. SHOP DRAWING SUBMITTALS, REQUESTS FOR INFORMATION OR CLARIFICA77ON OF DESIGN DOCUMENTS, AND PROPOSED FIELD
REVISIONS MUST BE SUBMITTED TO CSP ENGINEERING IN WRITING VIA FAX, EMAIL, OR U.S. POSTAL SERVICE. ALL
CORRESPONDENCE SHALL BE ROUTED THROUGH, REVIEWED AND COORDINATED BY THE ARCHITECT OF RECORD OR THE OWNER'S
SITE REPRESENTATIVE PRIOR SUBMISSION TO CSP ENGINEERING.
CUT / FILL / SITE STRIPPINGS / SOIL CONDITIONS
1. CUT, FILL, AND SITE STRIPPING QUANTITIES DELINEATED ON THESE PLANS WERE CALCULATED IN WHOLE OR IN PART UTILIZING
COMPUTER SOFTWARE COMPARING EXISTING GRADE CONTOURS TO FINISH GRADE CONTOURS AND CLEARING LIMITS ILLUSTRATED
ON THE PLANS AND DO NOT ACCOUNT FOR THE INSTALLATION OF UNDERGROUND UTILITIES OR STRUCTURES, SOIL SWELLING OR
SHRINKAGE, OR FOR UNSUITABLE MATERIAL WHICH MAY BE PRESENT ON THE SITE. CUT, FILL, AND SITE STRIPPING QUANTITIES
SHOULD BE CONSIDERED APPROXIMATE ONLY AND SHOULD NOT BE RELIED UPON FOR BIDDING PURPOSES.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR CALCULATING ANDIOR VERIFYING THE CUT, FILL AND SITE STRIPPING QUANTITIES
NECESSARY FOR THE IMPLEMENTA71ON OF THIS PROJECT. BOTH EXPORT AND IMPORT OF SOIL AND ROCK MATERIALS WILL BE
REQUIRED.
3. CONTRACTOR SHALL OBTAIN A COPY OF THE PROJECT GEOTECHNICAL REPORT (IF APPLICABLE) AND PERFORM ALL SITE
WORK IN STRICT COMPLIANCE WITH THE RECOMMENDATIONS CONTAINED THEREIN.
4. ANY DISTURBED, SOFT, OR LOOSE SOIL OR ORGANIC MATERIAL ENCOUNTERED DURING CONSTRUCTION SHALL BE EVALUATED
BY A GEOTECHNICAL ENGINEER TO PROVIDE REMOVAL ANDIOR REPLACEMENT RECOMMENDATIONS.
5. ALL Fit I SHALL BE PLACED ON SUITABLE NATIVE MATERIAL AS APPROVED BY GEOTECHNICAL ENGINEER WITH TOP 12"
COMPACTED TO A MINIMUM OF 95% RELATIVE COMPACTION.
6. FILL MATERIAL SHALL BE SUITABLE NATIVE MATERIAL APPROVED FOR USE BY A GEOTECHNICAL ENGINEER OR COMMON
GRAVEL BORROW (WSDOT 9-03.14) PLACED IN MAX 8" LIFTS AND COMPACTED TO 90% MAX DRY DENSITY (AASHTO T180) TO
WITHIN 2' OF FINISH SUBGRADE. TOP 2' OF FILL MATERIAL SHALL BE PLACED IN MAX 4" LIFTS AND COMPACTED TO 95% MAX
DRY DENSITY (AASHT0 T180).
SITE GRADING / EROSION CONTROL
1. AS A MINIMUM REQUIREMENT, ALL DISTURBED AREAS WITHIN RIGHT-OF-WAYS SHALL BE RETURNED TO THE EQUIVALENT OF
THEIR PRECONSTRUCTION COND17ION IN ACCORDANCE MTH APPROPRIATE REQUIREMENTS AND STANDARDS.
2. ALL DISTURBED SOIL AREAS SHALL BE SEEDED OR STABILIZED BY OTHER ACCEPTABLE METHODS FOR THE PREVENTION OF
ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. SEE EROSION CONTROL PLANS FOR SPECIFIC GRADING AND
EROSION CONTROL REQUIREMENTS.
3. THE CONTRACTOR SHALL KEEP OFF -SITE STREETS CLEAN AT ALL TIMES BY SWEEPING. WASHING OF STREETS WILL NOT BE
ALLOWED WITHOUT PRIOR APPROVAL.
4. SLOPE OF FINISHED GRADE SHALL BE CONSTANT BETWEEN SPOT ELEVATIONS SHOWN. TOPOGRAPHIC CONTOURS SHOULD BE
CONSIDERED APPROXIMATE ONLY AND SHOULD NOT BE RELIED UPON FOR FINAL SITE GRADING.
5. FINISHED GRADE OF LANDSCAPED AND OTHER PERVIOUS SURFACES SHALL SLOPE AWAY FROM BUILDINGS AT A MINIMUM OF
57. FOR A MINIMUM DISTANCE OF 10 FEET.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL INSTALL, MAINTAIN, AND REMOVE SHORING AND BRACING AS
NECESSARY TO PROTECT WORKERS, EXISTING BUILDINGS, STREETS, WALKWAYS, UTILITIES, OTHER EXIS77NG AND PROPOSED
IMPROVEMENTS AND EXCAVATIONS AGAINST LOSS OF GROUND OR CAVING EMBANKMENTS.
U711JTY CONNECTIONS / U71UTY INTERRUPTIONS
1. ALL WATERISEWERISTORMILITILITY CONNECTIONS, RELOCATIONS ANDIOR SERVICE INTERRUPTIONS SHALL BE ARRANGED FOR
AND COORDINATED IN ADVANCE WITH THE AFFECTED OWNERS AND APPROPRIATE GOVERNING AUTHORITIES INCLUDING THE FIRE
DEPARTMENT. CONNECTIONS TO EXISTING WA TERISEWERISTORMIUTILI TIES SHALL BE MADE ONLY WITH PRIOR WRITTEN APPROVAL
OF THE AUTHORITIES GOVERNING SAID UTILITIES.
2. EXISTING WATERISEWERISTORMIU71LI71ES WHICH ARE DAMAGED DUE TO CONSTRUCTION WORK SHALL BE REPAIRED AT
CONTRACTOR'S EXPENSE AND INSPECTED AND ACCEPTED BY THE LOCAL SITEIBUILDING INSPECTOR AND GOVERNING AUTHORITY
OF THE AFFECTED WATERISEWERISTORMILITILITY PRIOR TO BACKFILLING.
FINISH FLOOR ELEVATIONS
1. FINISH FLOOR ELEVATION (FFE) SHOWN ARE FOR GARAGE SLAB OF BUILDING. ELEVATIONS ARE APPROXIMATE AND ARE
INTENDED ONLY TO FACILITATE ROUGH GRADING OF SITE. ACTUAL FINAL DESIGN FINISH FLOOR ELEVATIONS SHALL BE
COORDINATED IN THE FIELD TO ACCOUNT FOR AS -BUILT CONDITIONS OF THE ROAD AND SITE WORK, FINAL BUILDING
CONFIGURATIONS, AND GARAGE LOCATION. UNLESS OTHERMSE NOTED, FINAL GARAGE FINISH FLOOR ELEVA71ONS SHALL BE SET
TO MAINTAIN POSITIVE DRAINAGE TOWARDS 'ME ACCESS ROAD.
CALL BEFORE YOU DIG 1-800-424-5555
SE 1/4, SECTION 25, TOWNSHIP 27 NORTH, RANGE 03 EAST, W.M.
REPLACE EXISTING GRAVEL/CONCRETE DRIVEWAY
WITH PERMEABLE CONCRETE PAVEMENT
WIMAX 2.0% SUBGRADE SLOPE (261 SF)
fNON-REGULATEDI
EXISTING SEWER M.H.
DATUM POINT @ 100.00'
EPLACE EXISTING ASPHALT DRIVEWAY (239 SF)
fREPLACED EXEMPTI
Ld
3:
Lj
00
M
SLOPE PAVEMENT TO VEST (TYP)
224TH ST. S.W.
STORMWATER MANAGEMENT PLAN
P=ff""!Mn' I SCALEI"=2
ill 0 f# i
\ CLEARING LIMITS
NEW ASPHALT PAVEMENT (333 SF)
PROFILE TO ACCOMODATE EXIS71NG SHEET
FLOW ADJACENT TO PAVEMENT EDGE
IREGULATEDI
NEW PERMEABLE CONCRETE PAVEMENT
WIMAX 2.07. SUBGRADE SLOPE (777 SF)
�R�EGULATE
3'xSx3' WASHED ROCK
DRYWELL FOR FOOTING DRAINS
4' PVC 2.00%
OVERFLOW
RAINGARDEN [I/Cl]
86 SF BOTTOM AREA
WIMINIMUM BTM ELEV
104.4 (VERIFY 1.0'
BELOW FE)
"`�414" PVC 2.007a
1 CD
CONNEC71ON POINT
FOR ROOF DOWNSPOUTS
NEW ROOF (1,439 SF)
,�v I EGULATED1
IN. �_ - _� 'A.T1
--- TEMP STOCKPILE
NEW PERMEABLE CONCRETE (4 SF)
IREGULATEDI I
ROOF DOWNSPOUT RISER PER ARCH PLANS
- SET INI ET 0.5' MIN ABOVE FFE (TYP)
I
S-1vt f-r-pt-v. -ro %a 11UfP-rAw'%V
c--p�AoripS 5,L4N0A?_v OwtAw
NOTES.
1. RAINGARDEN PLANTINGS SHALL BE AS RECOMMENDED BY A QUALIFIED NURSERY CONSISTING OF A MINIMUM OF 3
DIFFERENT SPECIES OF DEEP ROOTED, DENSE, DROUGHT TOLERANT SHRUBS ANDIOR HERBACEOUS PLANTS.
2. FLOOR OF RAINGARDEN SHOULD BE PLANTED WITH ZONE I TREES, SHRUBS AND GROUND COVER. SEE APPENDIX 3 -
"BIORETENTION PLANT LIST" IN THE LID TECHNICAL GUIDANCE MANUAL FOR PUGET SOUND (CURRENT EDITION).
3. SIDE SLOPES SHOULD BE PLANTED WITH ZONE I OR 2 GROUND COVERS.
4. BIORETENTION SOIL, COMPOS17ION AND pH LEVELS SHALL MEET THE STANDARDS SET FORTH IN THE LID TECHVICAL
GUIDANCE MANUAL FOR PUGET SOUND (CURRENT EDITION).
5. PLANTING SHALL CONSIST OF NATIVE SPECIES ABLE TO TOLERATE VARIABLE SOIL MOISTURE CONDITIONS, P%DING WATER
FLUCTUATIONS, AND VARIABLE SOIL MOISTURE CONTENT.
6. RAINGARDEN SHALL BE LINED WITH AT LEAST 12 INCHES OF BIORETENTION SOIL MIX COMPACT SUBSOILS MUST BE
SCARIFIED AT 4 INCHES BELOW THE AMENDED LAYER.
2"-4" QUARRY
SPALL SPILLWAY 2.0'
WIDE BY 0.3' DEEP
8 n DI DOMED DROP -IN GRATE
[HARCO 2013-002 OR EQUAL]
DOWNSPOUT INLET RISEP,
ACCEPTABLE TIGHTLINE
SDR 35 MATERIAL
SCH 40
N-12
F810 HANCOR
Appflwnt shal',4 repdrlfropfact� dl darriep to
Lfti4ties re?rontage tmprov "no nin In 0htj
rlgN-of-way per City standardn 5mt �s camod
or occurs durl-ing thn p=nq1ed prqjs-.t
RAINGARDEN MAINTENANCE.
1. THIS PROJECT INCORPORATES A STORMWATER MANAGEMENT FLOW
CONTROL BMP (BEST MANAGEMENT PRACTICE) CALLED A 'RAIN
GARDEN," WHICH WAS INSTALLED TO MITIGATE THE STORMWATER
QUANTITY AND QUALITY IMPACTS OF SOME OR ALL OF THE IMPERVIOUS
OR NON-NATIVE PERVIOUS SURFACES ON THE PROPERTY. RAIN
GARDENS, ALSO KNOWN AS "BIORETENTION," ARE VEGETATED CLOSED
DEPRESSIONS OR PONDS THAT RETAIN AND FILTER STORMWATER FROM
AN AREA OF IMPERVIOUS SURFACE OR NON-NATIVE PERVIOUS
SURFACE THE SOIL IN THE RAIN GARDEN HAS BEEN ENHANCED TO
ENCOURAGE AND SUPPORT VIGOROUS PLANT GROWTH THAT SERVES TO
FILTER THE WATER AND SUSTAIN INFILTRA71ON CAPACITY. DEPENDING
ON SOIL CONDITIONS, RAIN GARDENS MAY HAVE WATER IN THEM
THROUGHOUT THE WET SEASON AND MAY OVERFLOW DURING MAJOR
STORM EVENTS.
2. THE SIZE, PLACEMENT, AND DESIGN OF THE RAIN GARDEN AS
DEPICTED ON THIS PLAN MUST BE MAINTAINED BY THE HOMEOWNER
AND MAY NOT BE CHANGED WITHOUT WRITTEN APPROVAL FROM THE
CITY OF EDMONDS. PLANT MATERIALS MAY BE CHANGED TO SUIT
TASTES, BUT CHEMICAL FERTILIZERS AND PESTICIDES MUST NOT BE
USED. MULCH MAY BE ADDED AND ADDITIONAL COMPOST SHOULD BE
WORKED INTO THE SOIL OVER TIME
3. RAIN GARDENS MUST BE INSPECTED ANNUALLY FOR PHYSICAL
DEFECTS. AFTER MAJOR STORM EVENTS, THE SYSTEM SHOULD BE
CHECKED TO SEE THAT THE OVERFLOW SYSTEM IS WORKING PROPERLY.
IF EROSION CHANNELS OR BARE SPOTS ARE EVIDENT, THEY SHOULD
BE STABILIZED WITH SOIL, PLANT MATERIAL, MULCH, OR LANDSCAPE
ROCK. A SUPPLEMENTAL WATERING PROGRAM MAY BE NEEDED THE
FIRST YEAR TO ENSURE THE LONG-TERM SURVIVAL OF THE RAIN
GARDEN'S VEGETATION. VEGETATION SHOULD BE MAINTAINED AS
FOLLOWS.
A) REPLACE ALL DEAD VEGETATION AS SOON AS POSSIBLE,
B) REMOVE FALLEN LEAVES AND DEBRIS AS NEEDED;
C) REMOVE ALL NOXIOUS VEGETATION WHEN DISCOVERED;
D� MANUALLY WEED WITHOUT HERBICIDES OR PESTICIDES,
E DURING DROUGHT CONDITIONS, USE MULCH TO PREVENT EXCESS
SOLAR DAMAGE AND WATER LOSS.
TRAINGARDEN
SCALE 1 3'
0
12" BIORETENTION
SOIL MIX
I' ENVELOPE WASHED
DRAIN ROCK
-'-4" PVC INLET
x
8"x4" P VC TEE
W10PEN BOTTOM
FILTER FABRIC
ELEV 105.9
,mK FFE 105.4
VICINITY MAP
NTS
OWNER/APPLICANT
MELINDA & TIMOTHY STRAYER
22401 98TH AVE WEST
EDMONDS, WA 98020
CONTACT
CSP ENGINEERING INC PS
1037 NE 65TH ST #153
SEATTLE, WA 98115
TAX ACCOUNT NO
00450701200007
PROJECT DATA
PARCEL AREA: 0.19 ACRES
DISTURBED SITE AREA: 4,460 SF
NEWIREPLACED IMPERVIOUS SURFACE. Z605 SF
RAINGARDEN DESIGN
RAINGARDEN IS DESIGNED TO ACCOMMODATE 1,439 SF OF ROOF AREA AND 72 SF OF
UNMITIGATED NEW IMPERVIOUS SURFACE IN THE RIGHT OF WAY BASED ON AN
UNFACTORED INFILTRA71ON RATE OF 1.O'1HOUR (DESIGN LONG TERM RATE PER
GEOTECH REPORT IS 0.25"IHOUR WITH A 4.0 FACTOR OF SAFETY). A 5.7% SIZING
FACTOR WAS INTERPOLATED FROM HANDOUT #E72B TA13LE 5, 6" PONDING DEPTH.
RAINGARDEN SIZE 1,511 SF x 0.057 = 86 SF BOTTOM AREA.
ADDITIONAL PROJECT/SITE DEVELOPMENT INFORMATION
THIS STORMWATER MANAGEMENT PLAN ENCOMPASSES ONLY A PORTION OF THE
ENTIR&-SET OF PLANSIkEPORTS NECESSARY FOR IMPLEMENTATION OF TH6-PROJECT.
THE ARCHITECTURAL PLANS, RELATED REPORTS ANDIOR STUDIES CONTAIN ADDITIONAL
PROJECT INFORMATION ESSENTIAL TO THE PROPOSED IMPROVEMENTS AND SHALL BE
CONSIDERED AS INCORPORATED INTO THIS PLAN SET BY REFERENCE. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO OBTAIN ALL THE ABOVE REFERENCED INFORMATION
AND THE LOCAL PERMITTING AUTHOR17YS "APPROVED FOR CONSTRUCTION" VERSIONS
OF THESE PLANS FOR USE IN IMPLEMENTATION OF THIS PROJECT.
Line
Type
Area (square feet)
Non -Regulated
2.
Replaced
Exempt
Regulated
i I_;
' ' ' 1, 'S 0'
U
ARAGE & PAT101916
3.
4.
New (Post 1977) 4 4 4 4 4 4
Total Regulated Impervious
Mitigation required ifin excess of 000sf
19689
'29605_:
5.
6.
Total Area Mitigated by Existing Stormwater Management System(s)
Regulated Area Not Yet Mitigated
0
2,605,
7.
Area Proposed to be Mitigated by Low Impact Development Techniques
21605
8.
Area Proposed to be Mitigated through Conventional SWM Techniques
0
RZIT-0- YJAY CCNIS) 7FIXOT Ka'14 TERIPIT
AND 1N2'-PECTf0,N REQUIRED
3" DEPTH ASTM #57 4" DEPTH ACI
LEVELING COURSE 522 1-08 CONCRETE
77
MINIMUM 3" DEPTH 0.5n TO
UNIFORMLY GRADED CRUSHED
(ANGULAR) THOROUGHLY WASHED
STONE (ASTM #3)
PERMEABLE CONCRETE
IL N
PAVEMENT SECTION
NTS
0
APPROVED FOR CONSTRUCTION
rA
CITY ENGINEER DWIS16PJ 1JATLf
CITY OF EDMONDS
z
0
E
Uj
z
z
00
�
z
W
Q
a
Uj
LU
LL.
U.
00
WIWI
I
I
I
I
I
L
LU
W
C>
z
I
LU
�
�
�
�
3
az
CL
th,
A
at:
!Ali
L4
r= E
Ln
SO 08
Ln
00'.'D
04
ra
IS
%_
1A 04
'00
Oj
C
Z
Ln
rim
NO
Uj
z
@j
tA
M
k
* ?-Vf VjV- 'TO -5rrE 91APJ C-09- e9b%jeA) tdAft"L