Loading...
22619 95TH PL W.PDFiiiiii iiiiii 9368 22619 95TH PL W ADDRESS: TAX ACCOUNT/PARCEL NUMBER: 4d 54'�/g " 0 ZeO BUILDING PERMIT (NEW STRUCTURE): COVENANTS (RECORDED) FOR: CRITICAL AREAS:, 1�9',57-5(p DETERMINATION: [] Conditional Waiver tudy Required F _] Waiver DISCRETIONARY PERMIT DRAINAGE PLAN DATED: PARKING AGREEMENTS DATED: EASEMENT(S) RECORDED FOR: PERMITS (OTHER): PLANNING DATA CHECKLIST DATED: SCALED PLOT PLAN DATED: SEWER LID FEE $: SHORT PLAT FILE: LOT: SIDE SEWER AS BUILT DATED: SIDE SEWER PERMIT(S) #: GEOTECH REPORT DATED: STREET USE / ENCROACHMENT PERMIT #: WATER METER TAP CARD DATED: OTHER: LID #: BLOCK: LATEMP\DS'Ps\Forms\Street File Checklist.doc #P20 CA File NO: 06 -!�o .Critical Areas Checklist Site Information (soils/ topography/ hydrology/ vegetation) 1. Site Address/ Location: or2lif Property Tax Account Number: 6 2. 3. Approximate Site Size (acres or square feet): TAM Z'ff 4 A 6 E. 1w %Wjq.M- 4. Is this site currently developed? yes; _ no.. irth If yes; how is site developed? Wtl 5. �1- 7. W. -v� * Describe the general site topography. Check, h-1 - Flat less than 5-feet elevation change over entire site. Rolling- slopes on site generally less than 15% (a vertical rise of 10-feet over a horizontal distance of 66-feet). Hilly: slopes present on site of more than 15% and less than 30% (a vertical rise of 10-feet over a horizontal distance of 33 to 66-feet). Steep: grades of greater than 30% present on site (a vertical rise of 10-feet over a horizontal distance of less than 33-feet). Other (please describe): Site contains areas of year-round standing water: Approx. Depth: Site contains areas of seasonal standing water: Approx. Depth: . , What season(s) of the year? 8. Site is in the floodway floodplain of a water course. 9. Site contains a creek or an area where water flows across the grounds surface? Flows are year-round? Flows are seasonal? - (What time of year? 10. Site is primarily: forested meadow shrubs mixed urban landscaped (lawn, shrubs etc) 11. Obvious wetland is present on site: For City Staff Use 6nly (I =o4 1. Plan Check Number, if applicable? 2. Site is Zoned? PIS -91 3. SCS mapped soil type(s)? U - A (otr 4. Is. Critical Areas inventory or C.A. map indicates Critical Area on site? Site within designated earth subsidence landslide hazard area? DETERMINATION STUDY REQUIRED Reviewed by, �-110 5 /os7 WAIVER I J-�l - S-4L I KL C>r" L",L- 4VIIIN r 1-4 > IP4 1. t' #P20 City of Edmonds Development Services Department Planning Division Phone: 425.771.0220 Fax: 425.771.0221 The Critical Areas Checklist be filled out by Permi't A The pWs�e of R#IW g' of I J&JJ#1faff to det�p, ti OMticaTAreas are, or s su u je ec ct may J t property. ne information neededl 1b 'complete the Checklist should be easily available fi-o ni observations of the site or data available at City Hall (Critical areas inventories, maps, or soil surveys)- RECE IVED APR 1. 9 2005 Date Received: q-lq- a,5 City Receipt#: . .2(0 R�o Cf Critical Areas File #;->-�00-5 —QZ!� Critical Areas Checklist Fee:----$135.00 Date Mailed to Applicant:,L -T — / -7—c2001 1PP property owner, or his/her authorized representative, filli;ut the checklist, sign and date it, and submit it C . The City will review the checklist.make a &Pwsory site visit and make a determination of the subsequent steps necessary to complete a development permit application. Please submit a vicinity map, along with the signed copy of this form to assist City staff in finding and locating the specific piece of property described on this form.. In addition, the applicant shall include other pertinent information (e.g. site plan, topography map, etc.) or studies in conjunction with this Checklist to assistant staff in completing their prelinuinary assessment of the site. VLHMI I UOUNT ngl. The undersigned applicant� an s/her/its heirs, and assigns,:in consideration on the processing of the application agrees to release, indemnify, defend and hold the City.of Edmonds harmless from ainy and all dama es, including reasonable 9 attorney's fees, arising from any action or infraction based in whole or part upon false,' misleading, inaccurate or incomplete information famished by the applicant, his/her/its agents or employees. By, my signature, I cer* that the information and exhibits herewith submitted are true and correct to the best of my knowledge and that I am authorized to file this mpliqation on the behalf of the owner as listed below. SIGNATURE OF APPLICANTIAGENT LJ kV V 11 XI+M 111VI, DATE Property Owner's Authorization � J By my signature, I cer* that I have authohied the above Applicant/Agent to apply for the subject land use application, and grant my permission for the public officials and the staff of the City of Edmonds to enter the subject property for the purposes of inspection and posting attendant to this application. SIGNATURE OF OWNER - Owner/AppHcant: V4 9V 111 Name Street Address EPWRKI WA I �0?-o city Stite Zip Telephone: Y2-5-- Email address (optional): DATE Y-/q- 6t;- Applicant Representative: Name Street Address GMJf-bE .1 WA city State zip Telephone: Xt,- Email Address (optional):W&Awfli�Emwam W 0 0 CITY OF EDMONDS CRITICAL AREAS RECONNAISSANCE REPORT Site Location: 22619 — 95 th Place W. Tax Acet. Number: 00 5443 000 07 700 Determination: Study Required Determination #: CA-05-56 Applicant: Amy Frerker Owner: Michael & Carol Clark Case Design & Project Management CRITICAL AREAS RECONNAISSANCE REPORT: STUDY REQUIRED (CA-05-56) During review and inspection of the subject site, it was found that the site may contain critical areas, including Geologically Hazardous areas, pursuant to Chapter 23.40 of the Edmonds Community Development Code (ECDC). GENERAL CRITICAL AREAS REPORT REQUIREMENTS Critical Areas Reports identify, classify and delineate any areas on or adjacent to the subject property that may qualify as critical areas. They also assess these areas and identify any potential impacts resulting from your specific development proposal. If a specific development proposal results in an alteration to a critical area the critical areas report will also contain a mitigation plan. You have the option of completing the portion of the study that classifies and delineates the critical areas and waiting until you have a specific development proposal to complete the study. You may also choose submit the entire study with your specific development application. Please review the minimum report requirements for all types of Critical Areas which are listed in ECDC 23.40.090.D. There are additional report requirements for different types of critical areas (see below). Note that it is important for the report to be prepared by a qualified professional as defined in the ordinance. There are options on how to complete a critical areas study and an approved list of consultants that you may choose from. You may contact the Planning Division for more information. General Mitigation Requirements for all Critical Areas are discussed in ECDC 23.40.110 through 23.40.140. STUDY REQUIREMENT — LANDSLIDE HAZARD AREA It appears that this property contains or is adjacent to a Landslide Hazard Area. • A Landslide Hazard Area is any area with a slope of forty percent (40%) or steeper and with a vertical relief of ten (10) or more feet (except areas composed of consolidated bedrock). • Landslide Hazard Areas are further defined and illustrated in ECDC 23.80.020.B. • In addition to the general requirements for Critical Areas reports referenced above, specific Critical Area report requirements for Landslide Hazard Areas are provided in ECDC 23.80.050. DEVELOPMENT PROPOSALS ASSOCIATED WITH LANDSLIDE HAZARD AREAS Development is restricted within a Landslide Hazard Area and its buffer. • Projects that will intrude into these areas will require a report by a licensed Geotechnical Engineer. • The criteria that are applied depend on the amount that the buffer is reduced. The buffer can b It to a minimum of ten (11 e red 0) feet (with an additional 15' building setback per ECDC 23.40.280) if a report is prepared that meets the standards listed in ECDC 23.80.050). The alteration must also meet the requirements listed ECDC 23.80.060. In addition, proposals to reduce the buffer to less than ten (10) feet must comply with the design standards listed in ECDC 23.80.070.A.3. ALLOWED ACTIVITIES Certain activities are allowed in or near critical area buffers as specified in ECDC 23.40.20. If you have any questions about whether your proposed development qualifies as an allowed activity, please contact a Planner for more information. EXEMPT DEVELOPMENT PROPOSALS Certain development proposals may be exempt from Critical Areas Requirements (ECDC 23.40.230). If you think that a specific development proposal may be exempt, contact a Planner for more information. Name !, 2005 Date NOTE: Cited sections of the Edmonds Community Development Code (ECDC) can be found on the City of Edmonds website at www.ci.edmonds.wa.us. P) (X. AND DRAINAGF BY ENGINEERING--- gul I Im IL In, Jim- m0m-1 EXST. iMIRC61N GRADE OCtKIERY EXST. CONIC. A - CM rrA-%�.Y vq f AEWAr 2140 5TOWS��o -(AWE �77 . !!- ELEVi +lm:2� SOUTH PROP, LINE 181'-4-3/4" ;OT_FT- a CAT11 lASIl ON WEST SIDE 01 IOAD USED FOR DATUM POINT J* 74'-5)t ELEVt 1(my-o" WWI 9 EXISTING TWO I'TORY RESIDENCE 080 SF (IST FLOOR) 1,1082 SF IND FLOOR) RLEVe 991-41 24 I -opt LOT COVERAGE: IMPERVIOUS SURFACE CALCS. HEIGHT CALCS: 1966 SO, FT, (13.3%) EXISTING BUILDING ROOF OUTLINE: 1080 sf. (Const. 1974) A=1071-91, LOT AREA. EXISTING DRIVEWAY: 1790 St. (Const, 1974) B = 100'-0' 147810 $0. FT. EXISTING WALKWAY: 60 sf. (Const 1974) C=99-8" PROPOSED ADDITION: 498 Sf, PROPOSED CONC. SLAB: 225 sf, TOTAL EMSTING: 2930 of, TOTAL PROPOSED: 722 sf. TOTAL EX, + PROPOSED: 3652 sf, D=105'11" 21) -3 It 452-312 � I 1 DO' Lo AM A%.sh ul ATUL L I;R C%4 ELM 99141 TO MNNECT TO EX19T. 61'-9 '$ ACCEPTABLE TIGHTLINE MATERIAL RE:CEIVEED SQ R 35 SCH 40 APR 1 9 2005 N-12 OR M, PERMIT COUNTER NORTH P L'8� N APRIL-12,2005 CLARK RESIDENCE - ADDITION SCALE: 1 " = 20' AVE GMDE=103'-4" 22619 95TH PL, W. EDMONDS, WA 98020 ACTUAL= 118'-8 1/2" ` '% N MMIMUM=1031-41 + 251-01, =128'4" APPLI " T COPY le zqt6. S-4 GRESUB MAY 19 .2005 BUILDING DEPARTMENT C-M OF EDMONDS March 16, 2005 T9 GAU1 GROUP Project 1343-01 Geotechnical Consulting Tony Case Case Design and Project Management 3903 E. James Street Seattle, WA 98122 Subject: Geotechnical Reconnaissance Clark Residence 22619 - 95th Place W Edmonds, WA 98020 Dear Tony: On May 9, 2005, a geotechnical engineer from The Galli Group visited the above referenced site to evaluate the existing foundation and soil conditions. 'Me site is located on the East side of 95th Place W. at the toe of a slope that ascends to the North at an inclination of about 80 percent for a total vertical distance of about 20 feet before flattening out again- The purpose of our site visit was to evaluate the influence on the existing slope from constructing an addition on the southeastern end of the existing residence. As shown architectural site plan, proposed addition will be situated about 20 horizontal feet away from the toe of the steep slope. Geologic and Soil Conditions The existing house is situated on the south -facing slope of a draw that traverses a north -south trending ridge. Geologic maps of the area indicate that the site is likely underlain by glacial till and Advance Outwash (Geologic Map ofthe Edmonds East andpart ofthe Edmonds West Quadrangles, Washington, James P. Minard, 1983). Glacial till generally consists of unsorted mixtures of silt, clay, sand and gravel, "smeared" over the topography in front of the advancing glacier thousands of years ago. It was subsequently compacted by tons of ice. Glacial till tends to appear very dense, and can stand unsupported in near -vertical relief. When disturbed by moisture and traffic it can become unworkable. Advance outwash generally consists of glaciofluvial deposits of pebbly gravel and sand deposited in front of the glacier and then overridden by the advancing ice. The risk of erosion is greater in the granular advance outwash deposits than in the glacial till deposit. Advance 67R North 201 Lane, Seattle, Washington 98133 o Phone.(206) 546-8901 - Fax (206) 542-7625 Clark Residence — 22619 — 95 1h Place W. May 11, 2005 outwash generally appears stable when undisturbed and can stand in slopes approaching 100 percent if groundwater or surface water runoff is not present. We walked the property and noticed evidence of sandy gravel in shallow excavations for the fence, as well as where soil was exposed on the slope. Sand and gravel was also evident in open trenches being excavated on 95h Place. The observed soil appears more similar to advance outwash than glacial till, indicating that the site is likely situated near or below . the contact between the glacial till and the advance outwash. We did not observe any indications of slope movement on the site. Mature Douglas Fir trees dotted the slope and no evidence of surficial. erosion was evident. Surficial runoff is not directed toward the top of the slope from the property north of the site. No evidence of groundwater seepage was observed during our site visit. The existing basement wall and timber wall appeared to be functioning without distress. We observed no evidence of foundation settlement or cracking during our visit. Conclusions and Recommendations Based upon our geotechnical reconnaissance, the existing slope appears stable in its current condition. The proposed site improvements will not adversely impact the slope or slope system. Planned excavations consist of shallow excavations for spread footings. These will not adversely affect the existing slope or neighboring properties. The proposed addition will be situated about ten feet from the toe of a small portion of the slope (inclined at about 30 percent) and about 30 feet from the toe of the steep slope (inclined at about 80 percent as shown in attached site plan). This is sufficient to avoid risk to the current slope stability. We recommend restricting excavation on the steep slope and within 10 feet of the toe of the steep slope except for repair of fencing and similar minor soil disturbance. rom points of Site soils are subject to severe erosion potential if left unprotected, particularly f concentrated discharge, or side slopes from open excavations. We recommend covering stockpiled soil with plastic sheeting during inclement weather, and revegetating the exposed soils once construction is complete. A silt fence should be erected on the downhill side of the disturbed soil areas to prevent migration of sediment off site. Limitations and Additional Services The above recommendations are based upon observations of surficial. soil conditions encountered in our research and limited site reconnaissance.. If conditions are encountered during construction that vary significantly from those anticipated we should be advised so that we can revise our recommendations if necessary. This report is not intended as a warranty of the subsurface conditions. The above work was performed in general conformance with the state of practice for geotechnical engineering within the state of Washington within the limited scope of work for this project. 13521UTO 2 of 3 The Galli GrouP th Clark Residence — 22619 — 95 Place W. May 11, 2005 Please do not hesitate to call if you have questions regarding this report. Sincerely, 2 T ALL x I . 7" ! Z ( Paul L. Stoltenberg, P.E. Project Geotechnical Engineer Attached: Figure 1: Vicinity MaP Figure 2: Portion of Site Plan (reduced scale) (-05-- 11.152hrrot 3 of 3 The Galli Group 0 Clark Residence: 22619 W 95th P1, Edmonds, 98020, Page & Grid 474 HI CLARK RESIDENCE 1-15UKr- I It/A" Olt --------- Sides 7.5 1, '1-, \ � \1 "I Rear t \Date: Q NORTH PROP. LINE 181'-4-3/4' 0 —q -41= 4WD 07'-W 10' Lu EX. WAW 4VV�-- ELEV: 1001-W JLLJ vi-4— :3 EXISTING TWO RY RESIDENCE 1c.3 fA �MtrAfY �4� 1080 SF (IST FLOOFQ I z !% 1082 SF 04D FLOOR) IN T.66EWAV- E . 4r ELEV: 9W-W /IQ QMNE )T. -4-3/4" SOUTH PROP LINE 181' +1 4r L -- — — — — — — — — 24 —of$ TT- EX CATCH BASIN ON WEST SIDE 01 ROAD USED FOR DATUM POINT 74P-5)f SS LOT COVERAGE: IMPERVIOUS SURFACE CALCS. 1966 SQ.FT. (13.3%) EXISTING BUILDING ROOF OUTLINE: 1080 sf. (Const. 1974) LOT AREA. EXISTING DRIVEWAY: 1790 sf. (Const. 1974) 147810 SQ.FT. EXISTING WALKWAY: 60 sf. (Const. 1974) PROPOSED ADDITION: 498 sf. PROPOSED CONC. SLAB: 225 sf. TOTAL E)aSTING: 2930 sf. TOTAL PROPOSED: 722 sf. TOTAL Ek + PROPOSED: 3652 of. APPROVED AS NOTEU BY ENGIYERING ALL EXPOS 21 P-3ft ELEVi 1051.11" EXST. StfiIRSFON Z�RADE r> -EXST. —!�O(�KERY PROPOSED CONIC. VJ--1z7- %SLAB ELM 99%4'— ---7# WATPaf- L Wf� ELEV; 991-8" EXST. FENCE Zone-- Corner Flag_ TO Setback Required Actual kvQ Fnxt 2-5- .39, - 0 L0 0 �n C-3 C) 0 m CD CD M K. 451-3ft L 61'-9 of ACCEPTABLE TIGHTLAE APPROVED BY PLANNING MATERIAL MR 35 SCH 40 v HEIGHT CA=: N-12 A=107-9' F810 HMCOR NORTH B=100'-O" C=W-8" PLOT PLAN APRIL 12,2005 D=105'11" CLARK RESIDENCE - ADDITION SCALE: 1 u = 20' AVEGRADE=103!4' 22619 95TH PL. W. EDMONDS, WA 98020 ACTUAL=118'-81/2' MAXIMUM= 1034' + 25'-0" = 1294" STREET FILE 978M ST RE flesue PIR 19 2005 WIL01to t)epww-a-v dv OF aii*De Dv �W�Elmtr--) 0VW,WWYAY.lM4tC—V4) MOPOSED COK. SLA8. M 4 TO &�—t TO MWFOSMMil. TOTAU, MM�.-Zd. AppFOED By GENERAL NOTES 1.) .0 .1 =K,: ZI DESIGN LOADS: PROJECT INFORMATION: clp� Sim Lo* W7 SE&X DE" ITEI m REV. 5 �04:�2:20 05 8 2005 FLOOR AREAS �MT� ­9 =' " ==— V�SE�� im. — WOM WROORAWTUt mv SXTOT� TOT. —9 p.) HEIGHT CALCULATIONS: SCOPE OF WORK: m7m �T021QS`TVWr0ly 7 711. 4VEPL�EGRAMKX�. — 11— LEGAL DESCRIPTION: To— —m.$EcT"u.wmTuu LOT COVERAGE CALCS.- Lot— 1410 SF 3/1' - --------------- — — — — — — — — — — 1 0, - — — — . . . . . . . . . . . - — — — — — sin 10' u .. . ... .... .... Z VICINITY MAP: (9 "STM Mo E�XE g J, IMSF 00FLOOM ;z .O;ow Tm'� ADDrION a — EX CATCH BASIN ON WEST SIDE OF ROAD USED FOR DATUM POINT ogwoRogm /v cl INDEX: —w I IR— A 0 GEN NOTES,SITEPLAN, GALDESCRIPTION 1 LE Al I E)L 1ST&2ND FLOOR PLANS A21 FIRST AND SECOND FLOOR PI ANS A22 ROOF PLAN A31 BUILDING ELEVATIONS A32 BUILDING SECTIONS & WALL SECTION S21 FOUNDATION & 2ND FLOOR FRAMING PLANS A1.0 S22 ROOF FRAMING PLAN S2 3 STRUCTURAL DETAILS S2.4 STRUCTURAL DETAILS Page 1 of L, ME& Zulauf, JoAnne From: CADD casedesign [caddcasedesign@msn.com] RESUB Sent: Thursday, May 19, 2005 3:00 PM To: zulauf@ci.edrnonds.wa.us APR 19 200"! Subject: Case Design: Clark Residence -Topographic Revisions to Sheet A1.0 BUILDING DEPARTMENT cM OF EDMONDS Dear Ms. Zulauf, I've attached a PDF of the revised sheet A1.0. The changes that were made to this sheet were, just to the topographic contour lines running around the North side of the house. The noted elevations and elevation calculations were correct. I hope this information is enough to go on. Thank you for your help in getting this resolved. If you have any questions you can email me back here, or call me at 206-328-2520. Sincerely, -Tim Rahn Case Design 11 5/19/2005 0 0 PLANNING DATA NAME: Mirhafl & Carol r-larW_ DATE: ryl oAA '6 r of , 7�-o o &3 SITEADDRESS: 7.4�(Vlq 61 1VI Fla(e; Wt6l PLANCHK#: 05-li�j PROJECT DESCRIPTION: 9,1QVjiAr0.6TDry addi�ivn ID micitin!a 111ID-A' '51PP, Unctgd.e,�, m9laumrvit, of- &eCj!=) REDUCED SITE PLAN PROVIDED?: & N jo MAP PAGE: 10 CORNER LOT: FLAG LOT: (YYes �No ZONING:- P-.5 s -CRITICAL AREAS DETERMINATIONM 'P005- 0015(o 0 Study Required: A arld 91 f 016 "djtarj�, OLYCa, Ll Waiver (Ylt�ecj Ietj'C'Y -f-meyi &C.0'TeGV% 5,u itik, 6rhy Am-, 31itwoq Ll Conditional Waiver SEPA DETERMINATION: 6)(4r, VA ?4- U Fee U Checklist Ll APO list w/ notarized form L3 (Needed for 500 cubic yards of grading, Shoreline Area- site within 200 ft. of Puget Sound or Lake Ballinger) 0 Exempt( 11 (,Y40) SETBACKS: Required Setbacks: Street: 2 W Left Side: -4.5 Right Side: Rear: Actual Setbacks: -tv a4dVil Street: cl!9' Left Side: TV Right Side: Rear: (0 Street map checked for additional setback required? es-) No DNA) L3 DETACHED STRUCTURES: n0l3t 9,Y10Wn `-., n o mt r cA tA ROCKERIES: R.%1*6,tino re_taMfV1 5 WOLIJ 5VIO W Yj FENCES/TRELLISES: 4VU911VIS fC*-jrP, S �jc)Wvj BAY WINDOWS/ PROJECTING MODULATION: 6V)0WV) 0Y) 51+r, P STAIRS/DECKS: VXC91hV15 VY1 5V-41.61'C 9V10WV1) dc0l- -shown PARKING: Required: I- Actual: 1, ( meets S��loa cld-s ) LOT AREA: I 4-+e 10 4' ot a �Ycd: T-1, 0 " A I g I , 5 9 to Cl T� LOT COVERAGE = ICJ43 Calculations: I ol (9 (.p 115. 5 Y- i Y t V% LD�fc�*IIC -3 (0-04 4994'4-1092,4' BUILDING HEIGHT: 4-Aj&tjn5 CA+th 10401VI 01A W-CSt -A CZ TC4-a Datum Point: tp (&k of "a A Datum Elevation: + I Iq Maximum Allowed: 1-61 W2191 411) Actual Height(J-11-9 180") 15' 4.5 A.D.U. CREATED?& Yes - SUBDIVISION: ?Mf. GYr_tr+ 1511,- 000 Q- 010 TF- (93- LEGAL NONCONFORMING LAND USE DETERMINATION ISSUED: ()Le—s@ OTHER: Plan Review By: aA6�&Z U NewBPPlanningDataForrn. DOC IUM01 Ovv 219001 1 21900 906 21910 21911 =21-1�1M 21915 21830 < 1141 21900 1 0 21821 21823 900 2191,6 902 904 21920 21919 9630 21912 21909 21902 2190912190ii 9415 9413 2 '-' 21 g905, 2 '9'5 2 8 30 21.0. 2 '.02 2 21925 �947 L.O 7 9417 9407 T 22004 22004 22005 22004 22005 22006 22011 .14 !D 9304 '2 220G4� 22014 22015 22014 22"5 22014 _j — — 22014 IL (L 22017 1201 22017 22024 M 22017 22022 2014 22010 22016 t2 t; 22022 1221 M 22027 22030 22 29 220 22020 1223 22034 L11 27 22028 -- 22032 22039 22102 22104 22103 22042 o o 0 22106 7.-9 2204d32 22108 — 22115 22112 22109 22109 22110 2.2114 22044 NOSTSW 22124 22,16 — 8-52 22122 22121 22M 22122 21, 22050 22052 22053 22051 22124 Westgate — — 22MS 22203 22128 22129 22129 22130 221: f 22007 lementa 1237 ry 22210 22 14 22205 22206 22205 22205 22204� 2221 9601 22206 22009 22214 1251 22221 22225 22224 22218 22221 22219 — 22215 22216 222 22220 22218 22208 22209 22223 — 22220 22229 22223 22228 22227 222 1259 22229 22226 22228 22222 301 22224 22221 22220 2300 2230 223"03 22304 22305 22302 22226 22301 22304 22301 22: 2314 22311111 :--]7 223014 22306 22310 22311 22308 22307 22314 3: 22' r2231 0 3: i 22311 tu — — W w > 22311 > 232. 3* L" LwU �j 22315 > 0 22314 IL < 22315 22314 < _3 1 223171 22320 22317 IL x I I 22326 fz ,C) 9717 22320 cli 2323 9601 -21 -17 R 1� F 22318 224TH ST SW I 22407 > < 99ia 9902 9820 9808 401 �2 �22 22408 22407 22406 11 22405 417 22415 — 1224211 22416 _ 4 JE - 22414 22415 22414 1". 40 4 0 423 22422 22421 22405 22] 22408 22408 22423 22425 22424 — 22422 22421 22422 — 2 4 1 241 413 22423 — — 22428 22427 22428 22413 22412 22413 22416 22413 22416 22 22427 22 2 22431 22432 — 2 2 4 2 2242 439 42 22413 �J� 22430 [-5.3 22SU 22421 22420 22421 22420 22421 22420 22420 4"45 9855 9845 22504 22SO9 — Edmonds -- 22429 -- 22606 -- 22507 22506 22507 22506 22_- 5 0 2250 1"9 9924 05 9835 22506 22515 Presbyterian 22511 22510 22511 5 - 22510 - 22511 �;T2f2l 0 11 _5 2251 �57] 9w 9825 22522 22521 Church 22515 — 22514 ?2515 515 r2.251 — 22514 4 10 _52 2252 'k, 22*526 — — 22515 225161! .516 9 22531 22600 22519 22518 9 22516 22517 22518 2253 2603 4P 9807 22606 226 226TH PL SW 22605 22605 - 22604 - 22604 226,05 226( - ON9 0 9909 22615 22608 22808 22609 22608 .6 9816 22618 -- — 9916 2.2618 226217--3 22612 22613 22612 2.2613 22612 1 226; 1 22615 9908 J!!701� 9715 22628 22629 22620 22619 3. 22620 22619 221G4 9827 22710 7TH S&V 9713 22710 w > < 22711 22 06 -j 0- 22705 22708 3: -j 22706 IL — 3: w 7.1 9821 9724 9709 22718 0 Cr 22705 22 06 — I sw 22712 W > 22717 22719 (D 22715 22 2e 9820 — < 9706 x 9705 22727 9513 22721 9509 J 9826 22714 22731 9702 9701 22726 9505 22723 92031 22805 2280 22805 22803 22815 22811 22809 NDS WAY 22815 228 PL SW 22804 WestgatQ 1. 22810 X 22SG6\ Chapely 221 22808 9 #P20 0 1P. 167 - City of Edmonds Development Services Department Planning Division Phone: 425.771.0220 Fax: 425.771.0221 The Critical Areas Checklist be filled out by any Permit AbnlisaM am The pNMjig�eoif aff to t , d t ' k r de' rn Ms�u j e c�t I itoicaRe"asa e, or may property. The information ne&le*d complete the 'Checklist should be easily available from observations of the site or data available at City Hall (Critical areas invefitories, maps, or soil surveys)- 'RECEIVED' APR I � 9 2005 DateReceived: q-N-W) City Receipt #: a(0 gl� Cf Critical Areas File Critical Areas Checklist Fee: $135.00 Date Mailed to Applicant,,_�- 1-7-c�001 W property owner, or. his/her authorized representative, fill out the. checklist,. sign and date it, and submit it e City. The City will review the checklist,.make a awwry site visit, and make a determination of the subsequent steps necessary to complete a development permit application. Please submit a vicinity map, along with the signed copy of this form to assist City staff ;in finding and locating the specific piece of property described on this form. In addition, the "applicant. shall include other pertinent information (e.g. site plan, topography map, etc.) or studies in conjunction with this Checklist to assistant staff --ftf bdiiCpldtiiig—ttidii�-preliminary assessment of the site. The undersigned appli6an�'idi(Tliis/herfits heirs, and assigns, 'in consideration on the processing of the application agrees to release, indernnify, defend and hold the City.of Edmonds harmle s*s from any and all damages, including r easonable attorney's fees, arising from any action or infraction based in whole or part upon false,* misleading,' inaccurate or incomplete information furnished*by the applicant, his/her/its agents or employees. By. my signature, I certih( that the information and exhibits herewith submitted are true and correct to the best of my knowledge and that I am authorized to file this li ation on the behalf of the owner as listed below. SIGNATURE OF APPLICANTIAGENT —DATE— Property Owner9s Authorization By my signature, I cer* that. I ba autho ed the above Applicant/Agent to apply. for. the subject land use application, and grant my permission for the public officials and the staff of the City of Edmonds to enter the subject property forthe purposes of inspection and posting attendant to this application. SIGNATURE Of OWNER - Owner/Appficantt WAVI Name. Street Address EDWRMI WA Itozo city Stite zip DATE Applicant Representative:. &Y H tv: W 4,A\,KF1rZ / Name Street Address Gf �ATf WA city State Zip Telephone: Y2-5-- 4 -73 Telephone: )_C526 Email address (optional): #P20 CAFileNo- Critical Areas Checklist Site Information (soils/ topography/ hydrology/vegetation) 1.. Site Address/ Location: vuell orgif ry N 2. Property Tax Account Number: 6 0 ff 22 F 3. Approximate Site Size (acres or square feet)- L ---a + ##Al� , " T 7. 4: Is this site currently developed? X yes; no. b".4, _J70, If yes; how is site developed? that apply- 5. Describe the general site topography. Check all Flat less than 5-feet elevation change over entire site. Rolling: slopes on site generally less than .15% (a vertical rise. of .10-feet over a hdkzontal distance of 66-feet). Hilly: slopes present on site, of more than 15% and less than 30%. (a vertical rise of 10-feet over. a. horizontal distance of 33 to 66-feet). Steep: grades of greater than 30% present on site (a vertical rise of 10-feet over a horizontal distance of less than 33-feet). Other (please describe): 6. Site� contains areas of year-round standing water: Approx.. Depth. 7... Site contains areas of seasonal standing water: ;Approx. Depth:. What season(s) of ihe year? 8. Site is in the floodw�y floodplain 'a water course.. 9. Site contains -a creek or an area where water flows across the grounds surface? Flows are year-round? Flow's are seasonal? (What time of �year7 10. Site is, primarily: forested meadow ;shrubs mixed urban landscaped (lawn, shrubs etc) 11. Obvious wetlafid is pies�nt on site: 1 0=4 For City Staff Use Only 1. Plan Check Number, if,4ppficable?. 2. Site is Zoned? PIS -, 21 3. SCS mapped soil type(s)? U A (otr woo- - Lk m &.A S C.&I j Critical Areas inventory -or C.A. map indicates Critical Area. on site?. No 5. Site within designated earth subsidence landslide hazard area? No DETERMINATION STUDY REQUIRED WAIVER Reviewed 57 CITY OF EDMONDS CRITICAL AREAS- RECONNAISSANCE REPORT Site Location: 22619 — 95 th Place W. Tax Acct. Number: 00 5443 000 07 700 .Determination: Study Required Determination #: CA-05-56 Applicant: Amy Frerker Owner: Michael & Carol Clark Case Design & Project Management CRITICAL AREAS RECONNAISSANCE REPORT: STUDYREQUIRED (CA-05-56) During review and inspection of the subject site, it was found that the site may contain critical areas, including Geologically Hazardous areas, pursuant to Chapter 23.40 of the Edmonds Community Development Code (ECDC). a GENERAL CRITICAL AREAS REPORT REQUIREMENTS Critical Areas Reports identify, classify and delineate any areas on or adjacent to the subject property that may qualify as critical areas. They also assess these areas and identify any potential impacts resulting from your specific development proposal. If a specific development proposal results in an alteration to a critical area the critical areas report will also contain a mitigation plan. You have the option of completing the portion of the study that classifies and delineates the critical areas and waiting until you have a specific development proposal to complete the study. You may also choose submit the entire study with your specific development application. Please review the minimum report requirements for all types of Critical Areas which are listed in ECDC 23.40.090.D. There are additional report requirements for different types of critical areas (see below). Note that it is important for the report to be prepared by a qualified professional as defined in the ordinance. There are options on how to complete a critical areas study and an approved list of consultants that you may choose from. You may contact the Planning Division for more information. General Mitigation Requirements for all Critical Areas are discussed in ECDC 23.40.110 through 23.40.140. STUDY REQUIREMENT — LANDSLIDE HAZARD AREA It appears that this property contains or is adjacent to a Landslide Hazard Area. • A Landslide Hazard Area is any area with a slope of forty percent (40%) or steeper and with a vertical relief of ten (10) or more feet (except areas composed of consolidated bedrock). • Landslide Hazard Areas are further defined and illustrated in ECDC 23.80.020.13. • In addition to the general requirements for Critical Areas reports referenced above, specific Critical Area report requirements for Landslide Hazard Areas are provided in ECDC 23.80.050. DEVELOPMENT PROPOSALS ASSOCIATED WITH LANDSLIDE HAZARD AREAS Development is restricted within a Landslide Hazard Area and its buffer. • Projects that will intrude into these areas will require a report by a licensed Geotechnical Engineer. • The criteria that are applied depend on the amount that the buffer is -reduced. • The buffer can be reduced to a minimum of ten (10) feet (with an additional 15' building setback per ECDC 23.40.280) if a report is prepared that meets the standards listed in ECDC 23.80.050). The alteration must also meet the requirements listed ECDC 23.80.060. • In addition, proposals to reduce the buffer to less than ten (10) feet must comply with the design standards listed in ECDC 23.80.070.A.3. ALLOWED ACTIVITIES Certain activities are allowed in or near critical area buffers as specified in ECDC 23.40.20. If you have any questions about whether your proposed development qualifies as an allowed activity, please contact a Planner for more information. EXEMPT DEVELOPMENT PROPOSALS Certain development proposals may be exempt from Critical Areas Requirements (ECDC 23.40.230). If you think that a specific development proposal may be exempt, contact a Planner for more information. ruwell Name ure Date NOTE: Cited sections of the Edmonds Community Development Code (ECDC) can be found on the City of Edmonds website at www.ci.edmonds.wa.us. 2 NOTE: IF DRAWING SHEET IS NOT 24* X 36" THEN DRAVANG IS NOT TO SCALE. 25 0-0" yq IMPERVIOUS SURFACE CALCS. GENERAL NOTES: EXISTING BUILDING ROOF OUTLINE: 1080 sf. (Const. 1974) 1.) MECHANICAL AND PLUMBING SYSTEMS ARE TO BE BUILDER DESIGNED. VERIFY MECHANICAL SUPPLY AND RMRN LOCATIONS WITH ARCHITECT. EXISTING DRIVEWAY: 1790 sf. (Const. 1974) 2.) ELECTRICAL PERMITS ARE BY:lLECTRICAL CONTRACTOR. MECHANICAL PERMITS EXISTING WALKWAY: 60 sf. (Const. 1974) ARE BY MECHANICAL CONTRACTOR. . PROPOSED ADDITION: 498 sf. 3.) CONTRACTOR SHALL BE RESPONSIBLF'FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL APPLICABLE LAS, CODES, ORDINANCES, AND REGULATIONS. PROPOSED CONC. SLAB: 225 st 4.) ALL WORK AFFECTING NEW AND OWNG UTILITY SERVICE TO THE BUILDING OTAL EXISTING: 2930 sf. SHALL BE COORDINATED WITH THE UTIUIY,. PROPERTY OWNER AND THE CRY OF EDMONDS TOTAL PROPOSED: 722 sf. 5.) DO NOT SCALE DIMENSIONS FROM DRAWINGS. USE CALCULATED DIMENSIONS TOTAL Ek + PROPOSED: 3652 sf. ONLY. NOTIFY THE ARCHITECT IMMEDIA7ELY-. IF CONFLJdTS EXIST. 6.) CONTRACTOR SHALL VISIT JOB SITE,- AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS BEFORE PROCEEDING WITH THE WORK. DISCREPANCIES, IF ANY, ARE TO BE REFERRED TO THE ARCHITECT FOR DIRECTION PRIOR TO PROCEEDING WITH RELATED WORK. 7.) VERIFY ALL ROUGH -IN DIMENSIONS FOR EQUIPMENT FIXTURES AND OTHER ITEMS. PROVIDE ALL BUCK -OUTS, BLOCKING, BACKING AND JACKS REQUIRED FOR INSTALLATION. 8.) VERIFY LOCATIONS OF ALL EXISTING UTILITIES: CAP, MARK, AND PROTECT AS NECESSARY TO COMPLErE THE WORK. 9.) THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REVIEW OF MECHANICAL AND ELECTRICAL DESIGNS AND FOR CGORDINATIING WITH MECHANICAL AND ELECTRICAL CONTRACTORS BEYOND THAT DESCRIBED IN THE ARCHITECTURAL DOCUMENTS. 10.) THE CONTRACTOR SHALL CONSUL7 DRAWINGS AND OTHER DOCUMENTS OF ALL TRADES FOR ALL OPENINGS REQUIRED FOR THE CONSTRUCTION AND INSTALLATION OF DUCTS, PIPES, CONDUITS, EQUIPMENT, FIXTURES, AND CABINETS, AND SHALL VERIFY SIZE AND LOCATION. 11.) PROVIDE CLOSURE, MEEnNG THE R EQUIREMENTS OF GOVERNING FIRE AUTHORITIES, BETWEEN ALL FIRE RATED FLOORS, SHAFTS AND BUILDING PARTITIONS, AND ANY PENETRATING DUCTS, PIPES, CONDUIT, MECHANICAL, ELECTRICAL. AND OTHER ITEMS. 12.) ALL CONTRACTOR INSTALLED ITEMS7SHALL BE SUPPLIED WITH MECHANICAL AND ELECTRICAL SERVICES AS NECESSARY TO PROVIDE FOR THE FULL OPERATION OF THE ITEMS INSTALLED. DESIGN LOADS: GROUND SNOW LOAD: 25 PSF WIND SPEED: 85 mph SEISMIC DESIGN CATEGORY: D2 FLOOR AREAS: EXISTING FIRST FLOOR: 1080 SF EXISTING SECOND FLOOR: 10132 SF SUBTOTAL: 2162 SF FIRST FLOOR ADDITION: 392 SF SECOND FLOOR ADDITION: 498 SF SUBTOTAL: 890 SF TOTAL: 3052 SF, HEIGHT CALCULATIONS: GRADE POINTS AT BLDG RECTANGLE: A: 10T-9" B: 100'-0" C: 99'-80 D: 106-11" AVERAGE GRADE POINT: 103'41. ACTUAL BUILDING HEIGHT: 118A'1/2' MAXIMUM BUILDING HEIGHT: 103'4'+ 26-0" 1264' 9%0 vMer He LOT AREA: 14810 SF BLDG FOOTPRINT: 1966 SF 18 V-4,,�/4" e- CALCULATION: 1966 SF / 14810 SF 13.3% NORTH PROP. LINE 181'-4-3/411 LOT SLOPE: 20% %T� .................... AM TOTAL GRADING: 11 c.y. (NO GRADING PLAN REQUIRED, PER 0 #B61) Lu C4 SITE 0 L". lor_r ELEV- 1 OV-11�'� E --ELEV_l"-9-7 I L PROJECT INFORMATION: PROJECT LOCATION: 22619 95TH PL W. EDMONDS, WA 98020 OWNER: MICHAEL & CAROL CLARK TAX ASSESSOR'S f: 00544300006700 JURISDICTION: CITY OF EDMONDS, SNOHOMISH COUNTY CONSTRUCTION TYPE: V-B ZONING: RS-8 ARCHITECT: CASE DESIGN & PROJECT MANAGEMENT ATTN.: TONY CASE 3903 EAST JAMES STREET SEATTLE, WA 98122 (206) 328-2520 SCOPE OF WORK: 890 SF TWO STORY ADDITION TO 2162 SF TWO-STORY RESIDENCE. WORK INCLUDES REPLACEMENT OF SECOND STORY DECK LEGAL DESCRIPTION: PINE CREST BLK 000 D-00-TR 67 NEIGHBORHOOD - 1605000 TOWNSHIP 27, RANGE 03, SECTION 25, QUARTER SE Zone . , Comer Flag ge_tbacks Reguired Actual Front Sides Rear EXST. ROCKERY \cq DENOTES BUILDING RECTANGLE FOR HEIGHT 0 uj CALCULATIONS PER CITY OF EDMONDS LA_ PROPOSED CON��l C. I Al2 LOT COVERAGE CALCS.: To PO A 2 0 EU IW-W NOM cz 744-- VICINITY MAP: 10 EXISTING TWO 8fbRyRESIDENCE A OV A?FK04. WATION Or C" Effl ks -NqT LL_ C PF R NOT M SCALE 0 108'0 SF (I ST FLOOR) C E GH IN _A5ANwAL5D 1 0 U3 /1911 Y ENGINEERING 1082 SF (2ND FLOOR) aL, R 5 W5 4 uj Z I X10 12 RECEIVED w F8 H ; 0 Date: �3 fla Z G%wy!5f WfK PR OS ST AD ITI APR 1 9 2005 EXST. DRIV VATR fr. 392 (1 FL C4 PERMIT COUNTER E%_ wrNly ND 00 INDEX: ELEV: 9W4' ELEV-z 19 Al QMER&i) - .0 GEN. NOTES, SITE PLAN, LEGAL DESCRIPTION 'j-0 MNNFCIT To FxpsT. Sye;,,r. Bjo__� I A2.1 FIRST AND SECOND FLOOR PLANS C I ^ I r STS 23'-11 3/4 21'-3 1/4- 61'-9" >Tcl ST 1-cl I - L A9 9 Pnn P1 AN -7 A SOUTH PROP. LINE 1811-4-3/4" 45'-3" OWNERICONTRWCO�TOR IS RESPONSIBLE FOR ALL EXPOSED SURFACES TO ONTROL AND DRAINAGE +100lg EROSION Cf, BE COVERED WITHIN 2 DAYS EX. CATCH BASIN ON WEST SIDE OF ROAD USED FOR DATUM POINT' eTOM ��Wff,, PM%PW K64f 0 W SITE PLAN SCALE: 1/8'= V-0" ! hl N IN All BUILDING ELEVATIONS A3.2 BUILDING SECTIONS &WALL SECTION S2.1 FOUNDATION & 2ND FLOOR FRAMING PLANS S2.2 ROOF FRAMING PLAN 4517 A REGISTERM REV: 04-12-2005 4.4 0 C111 u cd 7 z a) Cj cq 0 0 -.4 "cl clq 00 c., c) r- kn a) 9z M g N rn cd 00 C; (u 44 6 N Z cd 0 en 7� c! C,� -0 cl c) �'c 4D rn 01� 0 C) C) cd I M u� cq cq ffll il; --TD -T L C) P,e9�)q `7S'—� PL CjaAr--, M-F, --. M 2-, � T ii Qf� j 2 , 119 00,474