22901 106TH AVE W (3).PDF1111111111
383
22901 106TH AVE W
� I
I
I
I
I
I
11
I
I
I
I
I
ce-40 15- —0 q q6
Edmonds School District No. 15
Sherwood, Elementary School
Traffic and Pedestrian Safety Improvements
Drainage eport
May 2015 1 Building Permit
AK "
A
Engineers
STREET FILE
RESUB
JUN 0 4 2015
BUILDI G DEPARTMENT
C17.� OF EDMONDS
R7 APPLICABI E
WATER CODE,
I
Drainage Report
May 2015
Prepared for:
Edmonds School District No. 15
20420 68th Avenue West
Lynnwood, WA 98036-7400
Prepared by:
KPFF Consulting Engineers
1601 Fifth Avenue, Suite 1600
Seattle, WA 98101
(206) 622-5822
KPFF Job No. 114407
C, I
Ke%
0
WVVIO:
4'
This report is prepared in accordance with Exhibit A: City of Edmonds Stormwater Code Supplement to
Edmonds Community Development Code Chapter 18.30.
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
Table of Contents
1 . Introduction .............................................................................................................................. 1
2. Existing Drainage ..................................................................................................................... 2
3.12roposed Drainage .................................................................................................................. 3
4. Applicable Minimum Requirements ........................................................................................ 4
MINIMUM REQUIREMENT 1 - Preparation of a Stormwater Site Plan ........... * ... *'*'*'*'* ........... * 4
MINIMUM REQUIREMENT 2 - Construction Stormwater Pollution Prevention Plan ................ 4
MINIMUM REQUIREMENT 3 - Source Control of Pollution ...................................................... 5
MINIMUM REQUIREMENT 4 - Preservation of Natural Drainage Systems and Outfalls ......... 5
MINIMUM REQUIREMENT 5 - On -site Stormwater Management ............................................ 5
MINIMUM REQUIREMENT 6 - Runoff Treatment ..................................................................... 5
MINIMUM REQUIREMENT 7 - Flow Control ............................................................................. 7
MINIMUM REQUIREMENT 8 - Wetland Protection .................................................................. 9
MINIMUM REQUIREMENT 9 - Operation and Maintenance .................................................... 9
MINIMUM REQUIREMENT 10 - Off -site Analysis ..................................................................... 9
MINIMUM REQUIREMENT 11 - Financial Liability ................................................................. 10
5.Conveyance System Analysis and Design .......................................................................... 10
6-Temporary Erosion and Sedimen tation Control (TESC) .................................................... 11
List of Figures
Figure1-1: Vicinity Map .................................................................................................................... 1
List of Tables
Table 1-1:
Disturbed Areas Summary ............................................................................................. 2
Table 3-1:
Table4-1:
Area of Sub -Basins (Proposed) .................................................................................... 3
Proposed PGIS .............................................................................................................. 6
Table 4-2:
Proposed Impervious Surface ...................................................... .........
Table 4-3:
Rain Garden Design Summary ................. I ..................................................................... 7
Table 4-4:
Flow Control Compliance ............................................................................................... 8
Sherwood Elementary Traffic and Pedestrian Safety Improvements- Edmonds School District No. 15
I
IAppendices
Appendix A —
Disturbed Areas Summary Map
Appendix B —
Existing and Proposed Site Conditions Maps
Appendix C —
Existing and Proposed Drainage Basins Maps
Appendix D —
City of Edmonds Storm Drain GIS Map
Appendix E —
City of Edmonds Project Classification Worksheet
Appendix F —
Civil Design Plans
Appendix G —
Geotechnical Engineering Memorandum
Appendix H —
MGS�Iood Reports: Rain Gardens
Appendix I —
MGSFIood Reports: Infiltration Basins
Appendix J
MGSFIood Model Snapshots
Appendix K
Conveyance Calculations
Appendix L
Rain Garden and Infiltration Basin Maintenance Standards
Appendix M
Settlement Tank Sizing Calculations
I
I
I
I
I
I
I
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
1 V
1. Introduction
The Edmonds School District (ESD) Traffic and Pedestrian Safety Improvements project is located at
Sherwood Elementary School at 22901 106th Avenue West in Edmonds, WA. The site is bounded by 106th
Avenue West to the west, 228th Street Southwest to the north, a forested slope to the east, and residential
homes to the south.
Q%q I
;. . .
I DW" 91
Edmonds
wit. s'
wwwst
s
E
Woodway
I A
2121h S1 sw
216th&SW 21 W
218%hSISW . 218thS15W
2201h St SW,
, ig . __ `/ i
Figure 1-1: Vicinity Map
R141 I
23fth 31 SW
2.d3 St SW
""'s'sw ..... . sw
Esperance
N\
23MSISW
MM & SW
S, sw
Mapk Ln 1E.
S, 5 W
2.m 6, sw
24214 S1 SW
2"th St SW
703ro sl
AY�WG
k Zomh 6� N SG
"'"'d'h'
S'
. 441
8111 Ad
1851h St
The overall project goal is to improve traffic and pedestrian safety at Sherwood Elementary School. Work
includes reorganization of parking and pick- u p/drop-off zones to improve efficiencies and red.uce pedestrian,
vehicle, and bus conflicts. As part of site reorganization, the project will construct new and replaced pavement
for traffic and pedestrian improvements. Landscape areas adjacent to parking and drive lanes will be re-
graded to accommodate expansion of paved areas. A new stormwater system will collect and convey runoff
from improved areas to two rain gardens for water quality treatment and on -site infiltration. Disturbed project
area is approximately 0.99 acres. Table 1-1: Disturbed Areas Summary outlines the proposed vs. existing
impervious surface within the disturbed area. Refer to Disturbed Areas Summary Map in Appendix A for
additional information.
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
Table 1-1: Disturbed Areas Summary
Surface Condition
PGIS'
Existing (acres)
0.41
Proposed (acres)
0.51
Change (acres)
0.10
NPG IS2
0.03
0.16
0.13
Pervious Area (Landscape)
0.55
0.32
(0.23)
Total
0.99
0.99
N/A
1: PGIS = New + Replaced Pollution Generating Impervious Surface
2: NPGIS = New + Replaced Non -Pollution Generating Impervious Surface
Since the project is in a creek basin and is considered a Small Site (less than one acre disturbed area) per the
Edmonds Stormwater Supplement, the project is required to comply with Edmonds -specific flow control
requirements. Compliance with flow control duration requirements of the SWMMWW is not required.
Additional information is provided herein.
2. Existing Drainage
Currently, the site consists of paved driveway and parking areas, sidewalks, fencing and gates, playground
areas, landscaping, and a playfield. The site generally slopes from the southeast to the northwest at grades
varying from 2 to 3 percent, with approximately 8 feet of relief across the site. Refer to the Existing Site
Conditions map (Bl) in Appendix B.
While the project is only disturbing 0.99 acres, there are existing site areas upstream and outside these
limits that are tributary to the site from a drainage perspective. As such, the "project site" has been defined as
an area encompassing 1.77 acres to adequately account for these upstream drainage areas. The existing
project site can generally be broken into three sub -basins, as shown in the Existing Drainage Basins map (Cl)
in Appendix C. A description of each sub -basin is provided as follows:
Existing Sub -Basin A encompasses 0.45 acres and is approximately 64 percent impervious. Stormwater is
collected by four catch basins that connect to the 1 8-inch concrete storm line running south to north
across the site.
Existing Sub -Basin B encompasses 0.99 acres and is approximately 91 percent impervious. Stormwater
flows to a bio-swale running south to north on the west,of the site. The bio-swale drains to a detention
pipe at the northwest corner of the site. The Drainage Report for previous development of the site (1995)
indicates that 1.37 acres flows to the existing bioswales and detention in this sub -basin. The 0.99 acres
indicated in this report only represents that portion of area within the limits of work fo r this project.
Existing Sub -Basin C encompasses 0.33 acres and is approximately 0 percent impervious. Stormwater
sheet flows across the playfield to a swale and infiltration trench at the western edge of the grassed area.
Excess flows from the swale are collected by a catch basin that connects to the 18-inch concrete storm
line at the northwest corner of the site. The northernmost portion of this basin sheet flows to off -site areas.
Stormwater runoff from the 18-inch storm line and the detention vault discharges to a 24-inch public storm
main. The storm main runs west along 228th Street Southwest and outfalls to Deer Creek. Refer to Appendix
D: City of Edmonds Storm Drain GIS Map.
KPFF Consulting Engineers
2
I
3. Proposed Drainage
As mentioned in Section 2: Existing Drainage, the project is disturbing 0.99 acres (see Table 1 -1); however,
there are existing site areas upstream and outside these limits that are tributary to the site. As such, the
project site" has been defined as an area encompassing 1.77 acres to adequately account for these upstream
drainage areas.
The proposed site will slightly modify the three existing sub -basins and add one new sub -basin, as shown in
the Proposed Drainage Basins map (C2) in Appendix C. A summary of proposed surface conditions for each
sub -basin is provided in Table 3-1.
Table 3-1: Area of Sub -Basins (Proposed)
Surface
Condition
New + Replaced
Impervious
A
B
I
C
I ?
D
I
Grand
Totals
PGIS
0.12 AC
0.10 AC
0.00 AC
0.29 AC
0.51 AC
Non-PGIS
0.05 AC
0.09 AC
0.00 AC
0.02 AC
0.16 AC
Subtotal
0.17 AC
0.19 AC
0.00 AC
0.31 AC
0.67 AC
Existing Impervious
(Not Disturbed)
PGIS
0.10 AC
0.51 AC
0.00 AC
0.02 AC
0.63 AC
Non-PGIS
0.04 AC
0.08 AC
0.00 AC
0.00 AC
0.12 AC
Subtotal
0.14 AC
0.59 AC
0.00 AC
0.02 AC
0.75 AC
Impervious Area
Subtotal
0.31 AC
0.78 AC
0.00 AC
0.33 AC
1.42 AC
Landscape Area
0.18 AC
0.04 AC
0.06 AC
0.07 AC
0.35 AC
GRAND TOTAL
0.49 AC
0.82 AC
0.06 AC
0.40 AC
1.77 AC
A description of the modifications to each drainage basin is provided as follows:
Proposed Sub -Basin A is 0.49 acres and approximately 63 percent impervious. Proposed development
will construct new asphalt pavement for parking and drive lanes, close an existing driveway on 106th
Avenue West with a new sidewalk, construct a concrete pedestrian island, re -grade the hillside adjacent to
106th Avenue West, and construct a new ADA ramp and stairs. One catch basin will be disconnected and
removed from the storm system. An additional catch basin will remain and continue to collect a portion of
flows from the upland impervious area. Remaining flows from Sub -Basin A will flow to two new catch
basins. These catch basins direct flow away from the existing 18-inch storm line to a new 8-inch storm
pipe that conveys stormwater to Rain Garden No. 1 at the southwest corner of the playfield. The rain
garden will provide treatment and flow control as described in Section 4: Applicable Minimum
Requirements'. Excess flows from the rain garden will discharge to the existing 18-inch storm main and be
conveyed to the existing City of Edmonds drainage infrastructure off -site.
Sherwood Elementary Traffic and Pedestrian Safety Improvements- Edmonds School District No. 15
Proposed Sub -Basin B is 0.82 acres and approximately 95 percent impervious. Proposed development will
provide new parking striping, reconfigure curb alignment for the bus turnaround, and construct a concrete
pedestrian island. Stormwater in Sub -Basin B will continue to flow to the existing bio-swale and detention
pipe along the north edge of the existing drive aisle.
Proposed Sub -Basin C is 0.06 acres and approximately 0 percent impervious. Proposed development will
relocate the existing swale and infiltration trench to the east of the new asphalt bus lane. No modifications
to the design of the existing system are proposed. A new yard drain will be located on the storm line to
the north of the site to collect excess flows from the swale. The storm line connects to the 18-inch storm
main downstream.
Proposed Sub -Basin D is 0.40 acres and approximately 87 percent impervious. Proposed development in
Sub -Basin D will construct new asphalt pavement to connect the existing north parking area and drive
lanes to the improved pick-up/drop-off zone at the southeast of the site. An asphalt bus lane and new
driveway on 228th Street Southwest will also be constructed in Sub -Basin D. Stormwater from these new
drive lanes will be collected by three new catch basins and conveyed by storm pipe to a rain garden at the
northwest corner of the site. The rain garden will provide treatment and flow control as described in
Section 4: Applicable Minimum Requirements. Excess flows from the rain garden will discharge to an
existing catch basin at the northwest corner of the site. Records drawings indicate that this catch basin
connects to the 18-inch storm main with a tee connection. Edmonds School District will be responsible for
maintaining this connection.
4. Applicable Minimum Requirements
Abcording to the Project Classification Worksheet from the Edmonds Stormwater Supplement (see Appendix
E) the site falls into the "Small Site Project" category because it includes less than 1 acre of land -disturbing
activity Refer to the Disturbed Area Summary Map in Appendix A and the information in Table 1 -1: Disturbed
Areas Summary for a summary of disturbed areas within the project site.
The following outlines the project approach to the applicable minimum requirements from the City of Edmonds
Stormwater Supplement (ESS).
MINIMUM REQUIREMENT 1 - PREPARATION OF A STORMWATER SITE PLAN
A stormwater site plan (C3.01: Grading and Drainage Plan) accompanies this report. Three copies have
been submitted for City of Edmonds review and a reduced -scale copy has been included in Appendix F: Civil
Design Plans for reference. This plan shows all locations of stormwater elements, as required by the
Edmonds Stormwater Supplement. Two rain gardens are implemented as a Low Impact Development (LID)
technique and provide treatment and flow control; see discussion in minimum requirement 5, 6 and 7 for more
information.
MINIMUM REQUIREMENT 2 - CONSTRUCTION STORMWATER POLLUTION
PREVENTION PLAN
A stormwater pollution prevention plan (C1.01: Temporary Erosion and Sedimentation Control Plan)
accompanies this report. Three copies have been submitted for City of Edmonds review and a reduced -scale
copy has been included in Appendix F: Civil Design Plans for reference. This plan shows the minimum
KPFF Consulting Engineers
4
U]
requirements for preventing erosion and discharge of sediments and other pollutants into receiving waters
during construction. Filter fabric fence will be used on the downhill side of all disturbed areas. Catch basin
protection will be provided for all catch basins subject to receiving sediment -laden flows. A temporary
drainage swale with sand bag check dams will be provided along the western edge of the sports field to direct
flows to a sump with pump. Captured flows will be pumped to a settling tank prior to discharging to the public
storm system. Note that since the site is disturbing less than 1 acre, compliance with the Department of
Ecology National Pollution Discharge Elimination System (NPDES) permit is not required.
Additional information for this element is provided in Section 6: Temporary Erosion and Sedimentation Control.
MINIMUM REQUIREMENT 3 - SOURCE CONTROL OF POLLUTION
The proposed site does not have any specific sources of pollution such as fuel tanks, chemical storage, or
vehicle maintenance yards. No specific source control Best Management Practices (BMPs) or spill prevention
plans are proposed.
MINIMUM REQUIREMENT 4 - PRESERVATION OF NATURAL DRAINAGE
SYSTEMS AND OUTFALLS
As determined by the topography of the project site, the proposed outfall is the same as the existing outfall.
The existing ouff all will be maintained. All stormwater runoff from the site will be routed to the 24-inch public
storm main in 228th Street Southwest, the current ouff all.
MINIMUM REQUIREMENT 5 - ON -SITE STORMWATER MANAGEMENT
Two rain gardens are selected to provide water quality treatment for this project. Infiltration basins will be
located below each rain garden to provide flow control compliance for the site. A geotechnical memorandum
summarizing a study of onsite soil conditions and infiltration rates is provided in Appendix G. The rain
gardens are designed in accordance with the LID Manual Section 6.1. See Minimum Requirements 6 and 7
for more information.
As required, BMP T5.13 Post -Construction Soil Quality and Depth will be used in all,landscape areas to reduce
runoff. A minimum of 8 inches of compost -amended soil will be placed in all landscape strips and islands.
MINIMUM REQUIREMENT 6 - RUNOFF TREATMENT
The project will develop 21,340 square feet (0.51 acres) of new plus replaced pollution generating impervious
surface (PGIS) (see Table 1 -1). This exceeds the threshold requirement of 5,000 square feet in the Edmonds
Stormwater Supplement; therefore, runoff treatment is provided for all proposed PGIS.
The project is located in Deer Creek Drainage Basin, which is considered a fish -bearing stream. Therefore,
enhanced water quality treatment must be provided for this project. Per Table 4-3 of the Edmonds Stormwater
Supplement, rain gardens are an ' approved method for providing enhanced treatment. Two rain gardens are
proposed to meet enhanced treatment requirements for the site.
Rain Garden No. 1 is located at the southwest corner of the playfield and receives flows from Proposed Basin A.
Rain Garden No. 2 is located at the northwest corner of the site and receives flows from Proposed Basin D.
Locations of the rain gardens and contributing drainage basins are shown in the Proposed Drainage Basins
map (C2) in Appendix C.
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
5
Runoff from new and replaced PGIS in Proposed Basin B is not captured by the two rain gardens, but instead
continues to flow to the bio-swale at the west of the site. Existing PGIS areas that contribute stormwater flows
to Proposed Basin A and Proposed Basin D provide an equivalent area of treatment in exchange for new and
replaced PGIS areas not captured by the two rain gardens. A summary of contributing PGIS areas to each
rain garden is provided in Table 4-1.
Table 4-1: Proposed PGIS
1: Existing PGIS contributing to Rain Garden No. 1 consists of 0.10 acres of existing PGIS from Sub -Basin A (see table 3-1) and an
additional 0.03 acres of existing PGIS outside the site area.
The proposed area of PGIS contributing to the two rain gardens is 0.56 acres. This area exceeds the 0.51
acres of new and replaced PGIS in developed conditions (see Table 1 -1); therefore, enhanced water quality
treatment is provided for this project.
Per the Stormwater Management Manual for Western Washington (SWMMWW) Volume 5 Section 4.1,
treatment facilities must be sized for combined runoff from both PGIS and non-PGIS areas if flows mix prior to
entering a treatment facility. Therefore, rain gardens for this project are sized to treat combined flows from
both PGIS and non-PGIS areas. A summary of contributing impervious areas (PGIS + non-PGIS) used to size
rain gardens is provided in Table 4-2.
Table 4-2: Proposed Impervious Surface
1: Existing impervious surface contributing to Rain Garden No. 1 consists of 0.14 acres of existing PGIS from Sub -Basin A (see table 3-1)
and an additional 0.03 acres of existing PGIS outside the site area.
Rain gardens have been designed in accordance with Section 6.1 of the LID Manual for Puget Sound. Per the
Stormwater Management Manual for Western Washington (SWMMWW) Volume 5 Section 4.1, water quality
treatment facilities must be sized to treat 91 percent of the 24-hour runoff volume, as computed by an
approved continuous runoff model. MGSFlood was used to size the rain gardens with a 15-minute timestep.
The dataset used was the Washington State Department of Transportation (WSDOT) Puget Sound 36 time
series. A summary of design characteristics for the, rain gardens is provided in Table 4-3.
KPFF Consulting Engineers
6
11
I I Table 4-3: Rain Garden Design Summary
Surface Condition
Contributing Impervious Area
Rain Garden No. 1
0.34 AC
Rain Garden No. 2
0.33 AC
Bottom Area'
17.4' x 287 (500 SF)
20' x 25' (500 SF)
Side Slopes
3H:1V
3H:1V
Storage Depth
6-inches
6-inches
Rain Garden Soil Depth
18-inches
18-inches
Rain Garden Soil Infiltration Rate 2
1.5 inches/hour
1.5 inches/hour
Rain Garden Soil Mix
BS M3
BSM3
Total Runoff Treated
93.82%
94.16%
1: Actual dimensions of bottom areas are irregular as shown on the stormwater plans. A best estimate of equivalent length and width
were determined for modeling purposes in MGSFIood.
2: Rain Garden Soil Infiltration Rate is based on a recommended value of 6 in/hr and correction factor of 4 per the LID Manual Section 6.1.
3: Per LID Manual Section 6.1
Stormwater filtered through the rain garden soil is designed to continue to infiltration basins below the rain
gardens for flow control. Flows exceeding the treatment capacity of the rain garden are designed to bypass
treatment through an overflow riser (Type 1 Catch Basin) and continue to the infiltration basin for flow control.
MGSFlood modeling of the rain garden design is described herein. Design details and treatment compliance
statistics for both rain gardens are provided in the IVIGSFIood reports in Appendix H. IVIGSFIood snapshots for
the water quality treatment model are included in Appendix J to accompany the model description.
The designed infiltration of treated flows from the rain garden to the infiltration basin is modeled in
IVIGSFIood with an underdrain that directs all treated flows from the rain garden cell to the infiltration
cell. In the model, the rain garden cell is linked to the downstream infiltration cell to model treated
flows moving from the rain garden facility via the underdrain to the downstream infiltration basin. The
model shows 0% infiltration for the rain garden cells to "native soil", indicating that 100% of treated
waters pass through the underdrain in the model to the downstream infiltration basin. Therefore, the
model properly accounts for all treated waters passing from the rain garden facility to the infiltration
basin as desi6ned.
The designed overflow of untreated flows from the rain garden to the infiltration basin is modeled in
IVIGSFIood with an overflow strycture (Type 1 Catch Basin) that directs all untreated flows from the
rain garden cell to the infiltration cell. In the model, the rain garden cell is linked to the downstream
infiltration cell to model untreated flows moving from the rain garden facility to the downstream
infiltration basin via the overflow structure. Therefore, the model properly accounts for all untreated
waters passing from the rain garden facility to the infiltration basin as designed.
MINIMUM REQUIREMENT 7 - FLOW CONTROL
The project will provide flow control for 29,185 square feet (0.67 acres) of new plus replaced impervious
surface (see Table 3-1). This exceeds the threshold requirement of 2,000 square feet in the Edmonds
Stormwater Supplement; therefore, flow control has been provided for the project.
I
Sherwood Elementary Traffic and Pedestrian Safety Improvements —.Edmonds School District No. 15
1 7
Since the project is in a creek basin and is considered a Small Site per the Edmonds Stormwater Supplement,
the project is required to comply with Edmonds -specific flow control requirements. Compliance with flow
control duration requirements of the SWMMWW is not required.
The project will utilize infiltration basins below the rain gardens to meet Edmonds -specific flow control
requirements for infiltrating facilities. A geotechnical investigation was preformed to determine on -site
infiltration rates and soil characteristics of native subgrade below the infiltration basins. The results of the
investigation are provided in the Geotechnical Memo in Appendix G. The method of determining on -site
infiltration rates complies with appendix C of the Edmonds Stormwater Supplement. The infiltration rate used
for design of the infiltration basins is 1 inch per hour.
Infiltration Basins Nos. 1 and 2 are located below Rain Gardens Nos. 1 and 2, respectively.
Runoff from new and replaced impervious surface in Basin B is not captured by the infiltration basins, but
instead continues to flow to the bio-swale and detention tank at the west of the site. Existing impervious areas
that contribute stormwater flows to Proposed Basin A and Proposed Basin D provide an equivalent area for
flow control in exchange for impervious surfaces not captured by infiltration basins. A summary of contributing
areas to the infiltration basins is provided in Table 4-2.
The proposed impervious area contributing to the infiltration basins is 0.67 acres. This matches the 0.67 acres
of new and replaced impervious surface in developed conditions (see Table 3-1); therefore, flow control is
provided for the project.
The infiltration basins are designed in accordance with section 3.3.10 of the SWMMWW Volume 3. Depth of
gravel is 2.5 ft in each basin below the bottom of the rain garden soil. The porosity of the gravel is assumed to
be 40%, and no slope is assumed at the bottom of the basins. 6-inch diameter perforated pipe connects to the
rain garden overflow structure to distribute stormwater evenly throughout the infiltration basin. A layer of 3/4
inch washed sandy gravel (City of Seattle Mineral Aggregate Type 26) will be placed between the rain garden
soil and gravel to prevent sediments from entering the gravel basin. Gravel below the 3/4 inch sandy gravel
layer will be 1-1/2 inch washed gravel. An overflow pipe for flows.exceeding the capacity of the infiltration
basins is located such that the invert of the pipe is at the top of the infiltration basin. Flows exceeding the
capacity of the infiltration basins are discharged to the existing 18-inch storm main.
The infiltration basins are sized according to Edmonds -specific flow control requirements for infiltration facilities
as listed in Table 5-3 of the Edmonds Stormwater Supplement. Because the project exceeds 5,000 square feet
of new plus replaced impervious surface, the infiltration basins must meet flow control requirements for 2-year,
1 0-year, and 1 00-year flows. MGSFlood was used to size infiltration basins with a 1 -hour timestep (refer to
the MGSFlood calculations in Appendix 1). A summary of compliance with flow control requirements is
provided in Table 4-4
Table 4-4: Flow Control Compliance
KPFF Consulting Engineers
8
I
I
MGSFlood modeling of the rain garden design is described herein. Design details and flow control compliance
statistics for both infiltration basins are provided in the MGSFIood Reports in Appendix 1. MGSFIood
snapshots for the flow control model are included in Appendix J to accompany the model description.
The infiltration basins are designed to receive stormwater from the rain garden through infiltration from
the bottom of the rain garden layer (treated flows) and through the overflow structure (untreated flows).
This is modeled in MGSFlood by linking the upstream rain garden cell to the downstream infiltration
cell. Treated flows from the rain garden cell in the model are collected by the underdrain and
untreated flows in the model are collected by the overflow structure. The link in the model directs
flows from the underdrain and overflow structure in the model to the infiltration cell. Therefore, the
model properly accounts for all waters passing from the rain garden facility to the infiltration basin as
designed.
The infiltration basins are designed to discharge flows in excess of infiltration capacity by means of a
storm drain pipe with the invert at the top of the infiltration basin layer. The point of compliance in the
model is set at the ouff low of the infiltration trench, which properly accounts for all flows in excess of
infiltration that are leaving the system through the outflow. The model report (Appendix 1) indicates the
2-yr, 1 0-yr, and 1 00-yr flows that leave the system. Table 4-4 demonstrates compliance with
Edmonds -specific flow control requirements.
MINIMUM REQUIREMENT 8 - WETLAND PROTECTION
There are no wetlands on the proposed site. No wetland protection is proposed.
MINIMUM REQUIREMENT 9 - OPERATION AND MAINTENANCE
Rain gardens shall be maintained in accordance with section 6.2.4 of the LID Manual for Puget Sound.
Infiltration basins shall be maintained in accordance with section 3.3.10 of the SWMMWW Volume 3. See
Appendix L for rain garden and infiltration basin BMP operations and maintenance standards.
MINIMUM REQUIREMENT 10 - OFF -SITE ANALYSIS
Existing runoff fr om site is routed to the 24-inch public storm main in 228th Street Southwest, leaving the site
to the west. In the proposed site, all runoff will be directed to the same discharge point. Stormwater will
continue to flow east and outfall to Deer Creek. See the Edmonds Storm Drain GIS Map in Appendix D for
location of the storm main and outfalls.
Conveyance System Capacity
Stormwater leaves the site via the 24-inch concrete storm main in 228th Street Southwest and flows to
Deer Creek. No known conveyance problems exist in this drainage network and no area is added to the
existing drainage basin as a result of this project. Due to the introduction of the infiltration basins, runoff
directed to the storm main in 228th Street Southwest is reduced. Therefore, no impacts are expected on
the existing conveyance system.
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
9
Localized Flooding
Localized flooding is not anticipated as a result of this project. There are no low spots created or altered in
this project. Furthermore, the bottoms of the infiltration basins are below the existing grade, with infiltrative
soils to ensure water will infiltrate deep into the subgrade.
Wetlands Impacts
There are no wetlands within the vicinity of the project. No impacts are expected.
Upland Erosion Impacts
There are no steep slopes in the vicinity of the project and no land cover changes are occurring. No
impacts are expected.
Stream Channel Erosion
As noted above, no tributary area is added to the conveyance system, proposed infiltration basins will
reduce runoff leaving the site, and flow durations for the project site are matched to the Edmonds -specific
requirements for 2-year, 1 0-year, and 1 00-year peak flows. The site discharges to the public storm drain
system and eventually Deer Creek; however, lower peak discharges are expected throughout the
downstream system and Deer Creek. Therefore, no stream channel erosion is expected.
Surface Runoff
Surface runoff enters the site from the east and exits on the west. It is currently captured in a series of
catch basins, routed to the existing public storm main in 228th Street Southwest and discharged to the
west. This configuration is maintained throughout the project. No impacts are expected.
MINIMUM REQUIREMENT 11 - FINANCIAL LIABILITY
A performance bond shall be posted by Edmonds School District as a financial guarantee for required
stormwater BMPs related to construction stormwater pollution prevention as required for commercial projects.
5. Conveyance System Analysis and Design
The proposed stormwater conveyance system consists of a series of catch basins which direct water to the
rain gardens and infiltration basins. Following treatment and flow control, runoff is directed to the 18-inch storm
pipe running south to north on -site and leaves the site through the 24-inch storm main in 228th Street Southwest.
Conveyance pipes used upstream and downstream of rain gardens are sized to convey the 1 00-year peak'
flow using the Rational Method, as detailed in the WSDOT Hydraulics Manual. A time of concentration of 5
minutes was used for the calculation. To compute rainfall intensity, m and n values were interpolated halfway
between Everett and Seattle. The computed 1 00-year rainfall intensity is 3.8 inches per hour. The capacity
calculations ignore any retention of flows provided by rain gardens and infiltration basins. At a minimum, 8-
inch HDPE pipe at 0.5 percent is used to convey flows from Proposed Basin A and Proposed Basin D. The
pipe has a full flow capacity of 1.25 cubic feet per second (cfs). This is greater than the -100-year peak flow of
1.23 cfs for the system contributing to Rain Garden No. 1, and 1.21 cfs for the system contributing to Rain
Garden No. 2. Refer to Appendix K for conveyance calculations of storm systems in Proposed Sub -Basin A
and Proposed Sub -Basin D.
KPFF Consulting Engineers
10
An existing 12-inch iron pipe at 0.5 percent conveys runoff from the proposed bus pick- up/d rop-off area in
Proposed Sub -Basin B to the bio-swale at the west of the site. Proposed surface conditions in Proposed Sub -
Basin B are not expected to increase peak flows to this pipe.
The existing swale and infiltration trench at the western edge of the playfield is being relocated and replaced
in -kind, per reorganization of the site. The replaced system will match infiltration trench size and 6-inch slotted
pipe.
6. Temporary Erosion and Sedimentation Control (TESC)
Construction stormwater best management practices (BMPs) will be implemented to prevent sediment -laden
water from leaving the site and entering the existing drainage system. These BMPs include typical cover
practices, inlet protection, and sediment barriers, as required.
Additionally, stormwater from those sub -basins that are not currently impervious (sub -basin C from the Existing
Drainage Basins map in Appendix B) will be conveyed to the low point of the basin and collected, via sump
and pump, before discharging to a settling tank. Settling tank has been sized for the 2-year peak flow per local
requirements. Minimum settling tank size shall be 8,800 gallons and shall have a minimum 2-foot storage
depth. Refer to Appendix M for a copy of the sizing calculation s for the settling tank. Note that the tank was sized
using a King County spreadsheet which meets the minimum requirements for the City of Edmonds.
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
11
U
Appendix A
Disturbed Areas Summary Map
I
I
I
I
I
I
I
I
I
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
1 Appendix A
NOTES
1. THIS PLAN SHOWS ESTIMATED DISTURBED
AREAS WITHIN THE PROJECT SITE ACCORDING
TO THE DEFINITION OF "LAND DISTURBING
ACTIVITY" IN THE DEPARTMENT OF
ECOLOGY'S STORMWATER MANAGEMENT
MANUAL FOR WESTERN WASHINGTON.
LEGEND
PROPERTY LINE
ROADWAY CENTERLINE
APPROXIMATE SITE
0
0 30 60 120
6ii�� , i—m�
1 inch = 60 feet
DRAWN BY DESIGNED BY
AJS AJS
CHECKED APPROVED BY call 811
two business days
1:
TJE TJE you Ig
DATE before you ndig
05/19/2015
J 0 B No. :114407 S C A L E:
AS SHOWN
106TH AWE W,
-� -1 -M) \
PROPERTY LINE
ESD SHERWOOD ELEMENTARY SCHOOL SHEET
DISTURBED AREA SUMMARY A_
I
Appendix B
Existing and -Proposed Site Condition Maps
I
I
11
.1
I
I
I
I
I
I
I
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
1 Appendix B
NOTES
1. APPROXIMATE SITE LINE INCLUDES DISTURBED
AREAS PLUS THOSE AREAS NOT -DISTURBED
BUT TRIBUTARY TO THE STORM DRAINAGE
SYSTEM..
2. REFER TO APPENDIX C FOR MAPS SHOWING
. DRAINAGE BASIN INFORMATION
LEGEND
PROPERTY LINE.
ROADWAY CENTERLINE
- — — — — - APPROXIMATE SITE (SEE NOTE 1)
j
"who,
14hr
0 30 60 120
1 inch 60 feet
DRAWN BY DESIGNED BY
AJS AJS
CHECKED BY APPROVED BY Call 811
IDdays
two business days
TJE TJE you g
befotire you dig
DATE
05 5
JOB No. :114407 S C A L E:
AS SHOWN
106TH W
L NDSCAPE
&qL Ali
ASPHALT
PARKING
ASPHALT
PARKIING
x
CM
t -f -n ) \
PROPERTY LINE
EXISTING STORMWATER
OUTFALLTO 228TH
W-A
DSCAPE
APPRQXIMATE SITE (SEE
f%
ESID SHERWOOD ELEMENTARY SCHOOL
EXISTING SITE CGISIDITIONS
SD
�-1!4 H
A*�
w"
SHEET
B1
NOTES
1. APPROXIMATE SITE LINE INCLUDES DISTURBED
AREAS PLUS THOSE AREAS NOT —DISTURBED
BUT TRIBUTARY TO THE STORM DRAINAGE
SYSTEM.
2. REFER TO APPENDIX C FOR MAPS SHOWING
DRAINAGE BASIN INFORMATION
.LEGEND
r,
71
0
0 30 60
120
1 inch
60 feet
=Now
DRAWN BY
DESIGNED BY
AJS AJS
Call 81
CHECKED BY
APPROVED BY
TJE
TJE
business days
--two
befo
DATE
05/l..9/201
5
S
C A L E:
JOB
No. :114407
AS SHOWN
9
106TH AE. W
Ln
LA
0
7�
PROPERTY LINE
--ji
RELOCATED —
STORAGE SHED
EXISTING STORMWATER
OUTFALL TO 228TH
n4wr
RAIN GARDEI
(BASIN D)
APPROXIMATE
P
�E NOTE 1)
ESD SHERWOOD ELEMENTARY SCHOOL
PROPOSED SITE CONDIT,'IONS
I
NO 2
SD
M-13
X
SHEET
B2
Appendix C
Existing and Proposed Drainage Basins Maps
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
Appendix C
DRAWN BY DESIGNED BY
AJS — — AJS Call 811
CHECKED BY APPROVED BY
TJE TJE two business days
14 befo
DATE
05/19/2015
JOB No. :114407 S C A L E:
AS SHOWN
%IL- DATE I V" before you dig I SHEET
05/19/2015 ESD SHERWOOD ELEMENTARY SCHOOL
JOB No. :114407 S C A L E: PROPOSED DRAINAGE BASINS C2
AS SHOWN Niff I I
Appendix D
City of Edmonds Storm Drain GIS Map
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
Appendix D
4 L14 (k
7 X&I 7-72-A.L..,L
4
7� 5-
A
AW. 10
IR
d
0-
A-
4f Awl
0k;
(50
4, -
6
1:3,321
138.39 276.8 Feet
This map is a user generated static output from an Internet mapping site and is for
reference only. Data layers that appear on this ma P may or may not be accurate,
S-1984-Web-Mercator�-Auxiliary-Sphere current, or otherwise reliable.
ity of Edmonds THIS MAP IS NOT TO BE USED FOR DESIGN OR CONSTRUCTION
r
Aetl' -
Lynn�od
4nds
M
(Woodw-'�--i.
e
Legend
0
Storm Catch Basins
*
Storm Manholes
*
Detention Facilities
0
Culvert
0
Facility Feature
—
Storm Une
—
Ditch and Creek
Facility Unes
i—i
Administrative Boundaries
Notes
Appendix E
City of Edmonds Project Classification Worksheet
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
Appendix E
APRL2010
k LVA 19, 0 1-.4".1 M Z IT, AT/M I z ztkk P, :W
Figure 2-1: Project Classification
Does the project involve I - Yes
acre or more of land -
disturbing activity?
I No
Yes
Is the project part of a larger
common plan ofdevelopment
or sale where the total
disturbed area for the entire
plan will total I -acre or more
I of land -disturbing activity?
I No
Does the Project involve one or more of the
following:
2,000 square feet or more of new impervious
surface, replaced impervious surface or new
plus replaced impervious surface?
OR
7,000 square feet of land -disturbing activity?
OR
50 cubic yards or more of either grading, fill,
or excavation as defined in Chapter 18.40.000
ECDC?
No
Minor Site Project:
Read Chapter 3 and see
Chapter 6 for requirements
Large Site Project:
Read Chapter 3 and see
Chapter 4 for
requirements
Does the project create or add 5,000 square feet of
new impervious surface, replaced impervious surface
or new plus replaced impervious surface?
OR
Yes Convert % acre or more of native vegetation to lawn
10 or landscaped area
OR
Tlirough a combination of creating effective
impervious surface and convertedpervious
surfaces, causes an increase of 0. 1 cubic feet per
second in the 100-year flow frequency from a
threshold discharge area as estimated using an
approved model?
No I Yes
Category 1 Small Site Project:
Read Chapter 3 and see Chapter 5
for requirements
1 Assumes the project in question meets applicability requirements of ECDC18.30.030.
Category 2 Small Site Project:
Read Chapter 3 and see Chapter
5 for requirements
011 10804140000edmondsstmmwatersilpolemelrtfinaldoc 2.0 CLASSIFYING PROJECTS 5
I
Appendix F
Civil Design Plans
I
71,
I
F-7 I
I I
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
1 Appendix F
FA
E5
TH
:--- 7_1T ---------
APPROXMATE LIMITS
OF WORK (TYP) I
2 CATCH B �OT��MTION
c7.Di PER COZ�_ E1.3 (TYP
- - - - - - - - - - - - -
TEMPORARY EROSION AND SEDIMENT CONTROL NOTES
7�i
PER_CIE�§T6 E1.3 (TYP)
t j 14__� I 1� I
=LLL 1 PR U1
U1
"77 777,
-TANK (APPROXIMATELY
FILTER F
IT 10 FIELD
DOE ANkADJUST THE
I
SZE I
'S Of- THE TANK AND
�._SFTTLEAGIIME AS-KEED
'��TER FABRIC FENCE PER �
E1.1 (TYP)
G
Cowl Cm
, 1—ti—rF ffi
CE
T TO LOCATE
OTEC TRATION
qnON
A
r1a
2**�CATCH BASIN PROTECTION IN,
= PER COE STID E1.3 (TYP)
C701
APIP�ROMA -1
r INFILTRAMON AREA TE]M=ZIN GEM OF WORK (TYP)
ALL CONSTRUCTION SWA CTI /2
'S. SEE NOTE FIELD LOCATE
LEGEND:
m
NI MOBILE 55 GALLON 0" WITH RJMP.
t (TYP) L COLLECT SlORM WAIR�MD PUMP T( 4
CE @C102 SEDIMENT T L CONTRA To- C11 * 02
CT, I
CONTRACTOR TO FIEUD�OCATE SELE PUMP AND F ELDUZiIE
CITY OF EDMONDS RECOMMENDED CONSTRUCTION SEQUENCE NOTES
1. SCHEDULE A PRE -CONSTRUCTION MEETING WITH CITY ENGINEERING DIVISION AT 425-771-0220, EKT. 1326.
Z REVIEW TESC NOTES.
3. CALL FOR UTILITY LOCATES.
4. LOCATE INFILTRATION BASINS AND INSTALL CONSTRUCTION FENCE AROUND.
5. INSTALL ESC MEASURES AND MAINTAIN DUST CONTROL
6. HAVE EIROSON CONTROL MEASURES INSPECTED BY CITY OF EDMONDS CITY ENGINEERING INSPECTOR. (ALL
TEMPORARY SEDIMENTATION AND EROSION CONTROL MEASURES MUST BE IN PLACE AND INSPEC7ED PRIOR
TO ANY CONSTRUCTION OR SITE aZARING, EROSION AND SEDIMENTATION CONTROL PRACTICES AND/OR
DEVICES SHALL BE MAINTAINED UNTIL PERMANENT VEGETATION IS ESTABLISHED.)
7. ROUGH GRADE STE AS REQUIRED TO INSTALL DRAINAGE FEATUIRIM
& DEMOLISH EASTING STRUCTURES.
9. CUM, GRUB & ROUGH GRADE REMAINDER OF STE. REVEGETATE DISTURBED AREAS NOT SUBJECT TO
ADDITIONAL SMACE DISTURBANCE IMMEDIATELY AFTER ROUGH GRADING. (OTHER DPOSED AREAS SHALL
BE STABILIZED PER EROSION CONTROL NOTES BELOW)
10. INSTALL UTILITIES AND 07M SITE IMPROVEMENTS.
11. STABILIZE AND REVEGETATE ENTIRE SITE. DISILMED SOILS SHALL BE COMPOST AMENDED PER CHAPTER 5
OF THE D.O.E. STORMWATER MANAGEMENT MANUAL FOR WESTERN WASHINGTON.
12. ESTABLISH LANDSCAPING AND PERMANENT VEGETATION. EROSION CONTROL FEATURES CAN BE REMOVED
UPON FINAL SITE STABILIZATION AND APPROVAL BY CITY INSPECTOR.
— - - — PROPERTY LINE FUTURE INFILTRATION AREA SEE NOTE 8
— — — — APPROAMATE LIMITS OF WORK
0 N FILTER FABRIC FENCE
TEMPORARY CHAIN LINK CONSTRUCTION FENCE
CATCH BASIN PROTECTION
TEMPORARY DRAINAGE SWALE FLOW LINE
SAND BAG CHECK DAM
0 MOBILE 55 GALLON DRUM WITH PUMP
TEMPORARY SEDIMENT TANK 0 10 20 40
I kmh - 20 fee
DRAWN BY DESIGNED By A APPROVED FOR CONSTRUCTION L)NIONDS SHERWOOD ELEMENTARY SCHOOL TUFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS SHEET
KWIP/TY AJS
CHECKED BY APPROVED BY Call 811
tww*=&p q)ff CITY OF EDMONDS EDMONDS, WASHINGTON
TJE TJE Le bd- you 09 WA 99101 DATE'
OA_ff Z06AMSIZZ
05/27/2015 -.kPfF- 4rM ey.6 TESC PLAN ci .01
S C A L E: I
mul aTY ENGWROG DMON SKC L
NO. DATE BY CHD. APPR. REMSION J 0 B No. :114407 AS SHOWN DISTRICTi FOR PERMIT
1. TESC FACILITIES SHALL BE INSPECTED DAILY BY THE
CONTRACTOR AND MAINTAINED AS NECESSARY OR AS
DIRECTED BY THE CITY INSPECTOR TO ENSURE CONTINUED
AND PROPER FUNCTIONING. CONTRACTOR SHALL SPOT CHECK
TESC FACILITIES TO ENSURE SEDIMENT AND POLLUTED RUNOFF
WILL NOT LEAVE THE WORK AREA.
Z CATCH BASINS ADJACENT TO THE PROJECT SITE SHALL BE
INSPECTED DAILY BY THE CONTRACTOR. RUNOFF LEAVING THE
SITE DURING CONSTRUCTION, INCLUDING WATER CARRIED BY
THE TRUCK TIRES, SHALL BE CLEAN. CONTRACTOR SHALL
CLEM CATCH BASINS AND IMPLEMENT DITRA SEDIMENTATION
CONTROLS IF NECESSARY AND AS DIRECTED BY THE CITY
INSPECTOR AND THE OWNER.
3. SITE INSPECTIONS SHALL BE CONDUCTED BY A CERTIFIED
EROSION AND SEDIMENT CONTROL LEAD (CESCL) WHO SHALL
BE PRESENT ON SITE OR ON -CALL AT ALL TIMES.
4. CONTRACTOR SHALL PROVIDE CONSTRUCTION FENCING AS
REQUIRED FOR SAFETY AND AS DIRECTED BY THE INSPECTOR.
FENCING SiALL BE PLACED IN A MANNER THAT ALLOWS FULL
USE OF ENSTING ADJACENT FAaUTIES. IN THE EVENT THAT
ACCESS TO THOSE FACULTIES CANNOT BE MAINTAINED.
CONTRACTOR SHALL PROVIDE ONE WEEKS WRYTTEN NOTICE TO
THE SCHOOL DISTRICT PROJECT MANAGER
5. CONTRACTOR SHALL PREVENT ON-STE EROSION BY
STABILIZING ALL SOILS, INCLUDING STOCK PILES THAT ARE
TEMPORARILY DG�OSED.
6. NO SEDIMENT SHALL HE TRACI(ED ONTO PAVED SURFACES.
SEDIMENT SHALL BE REMOVED FROM TRUCKS AND EQUIPMENT
PRIOR TO LEAVING THE STE. IN THE EVENT OF FAILURE OF
THE TESC SYSTEM RESULTING IN SEOM94T BEING TRACKED
ONTO PAVED SURFACES. THE CONTRACTOR SHALL
IMMEDIATELY IMPLEMENT MEASURES TO CORRECT THE
SITUATION.
7. CONTRACTOR %IALL PREPARE AND SMT A DETAILED
CONSTRUCTION SEQUENCE PRIOR TO COMMENCING WORK. CITY
OF EDMONDS RECOMMENDED CONSTRUCTION SEGUENCE NOTES
ARE PROVIDED ON THIS SHEET.
8. INFILTRATION AREAS SHALL BE FULLY PROTECTED FROM ALL
DUETE]RIOUS MATERIALS (SEDIMENT, CONSTRUCTION DEBRIS,
STOCKPILF, ETC) AND FROM ANY CONSTRUCTION TRAFFIC
DURING ALL CONSTRUCTION ACTIVITY. PRIOR TO COMMENCING
WORK FIELD -LOCATE INFILTRATION FACILITIES (SEE C3.01) AND
ERECT CONSTRUCTION FENCE SJRROUND(NQ ANY
UNAUTHORIZED ACTIVITY WITHIN INFILTRATION BASINS
RESULTING IN REDUCED INFILTRATION CAPACITY AS
DETERMINED BY THE OWNER SHALL BE FULLY REPAIRED AT
CONTRACTOR E)MSE.
9. SEE SHEET C7.01 FOR CITY OF EDMONDS STANDARD DETAILS
" 0 MIN.,
RACE DONMREAM CHECK DAM SO
12�-O MAX. TWISTED SELVAGE
THAT TOP OF DAM IS APPROXIMATELY
LEVEL
F TOP AND BOTTOM
- - - - - - - - - -
WITH THE LOWEST GROUND
ELEVATION OF UPSTREAM CHECK DAM.
/
11
1 1 F I WIR V v v w IV, w Irl IV, W, IV,
51 *1
te
I SM A, w w w w ,, w A V ww
1 w W W �19 sW 414;,VWW
MIMI #
............ W
4V-W-4, - - - - - - - - - - - - - - -- - - - - -
2 BAGS HIGH
W W
ON FILTER FABRIC
;f*
PROMDE SOLID COVER
FOUNDATION
6'-0
x
F"
�-60*t
TOP OF DRUM SHALL BE
6* MIN. ABOVE GRADE
W-4, RUNOFF TH 771
LEVEL BOTTOM OF A PROPER' Y
F INSTALLED SAND BAG BARRIER SEDIMENT
DISCHARGE
hm
1. CHAIN UNK FABRIC TO BE MIN. 11 GAUGE, GALVANIZED. NO RUSTED OR
EXCESSIVELY MALFORMED FABRIC.
Z FENCE BASES SHALL BE OF SUFFICIENT WEIGHT AND/OR SPREAD TO
ADEQUATELY SUPPORT EACH PANEL
3. PANEL —TO —PANEL CONNECTIONS SHALL BE MADE AT A MIN. TWO
LOCATIONS PER CONNECTION UNLESS OTHERWISE APPROVED.
4. PROMDE CONSTRUCTION WARNING SIGNAGE 50'O.C. ALONG FENCING
INSTALLATION.
TEMPORARY CHAINLINK FENCE DETAIL
NTS
MAINTENANCE STANDARDS,
1. DAMAGE RESULTING FROM RUNOFF OR CONSTRUCTION ACTIVITY SHALL BE
REPAIRED IMMEDIATELY.
2. IF THE FACILITIES 00 NOT REGULARLY RETAIN STORM RUNOFF. THE
CAPACITY AND/OR FREQUENCY OF THE DKES/SINALES SHALL BE INCREASED.
TEMPORARY 'DRAINAGE SWALE
NTS @
PROPER PLACEMENT OF SAND BAG
BARRIER IN A DRAINAGE WAY
$CONTRACTOR SHALL MAINTAIN AND REPLACE CITY INSPECTION REQUIRED ON ALL
SANG BAGS TO INSURE PROPER EROSION EROSION CONTROL METHODS BEFORE
CONTROL IOTHER WORK CAN BEGIN.
SAND BAG CHECK DAM
FILTRATION SYSTEMS DETAIL
NTS
NQIL
PUMPS SHALL BE SUBMERSIBLE, AND HAVE A MINIMUM
CAPACITY OF 0.22 CFS (98 GPM�
MOBILE 55 GALLON NTS DRUM WITH PUMP @
i
DRAWN BY DESGNED BY 4 EDIME)NIM SHERWOOD ELEMENTARY SCHOOL TRAMC AND PEDESTRIAN SAFETY IMPROVEMENTS SHEET
KWP/TY A's Scau APPROVED FOR CONSTRUCTION E
CHEO(ED BY 811 CITY OF EDMONDS DMONDS, WASHINGTON
APPROVED BY ft- I dup 1601 Rh �-, Suk. l6w
TJE TJE bd- you dg r r WA 11 11
ATE 20&622-%M DAIL
D TESC DETAILS
05/27/2015 C E: or. C1.02
CITY ENCRUMG R�ffffi SCH(I)L
NO. DATE BY CHO. APPR. REVISION JOB No. :11W7 AS SHOWN DISTRICT FOR PENN
Big
— IAW
W� mr x r
14 � � F�c
EM"
rq
-,, Z
.Q.
I
A
I.F..
a.
ARX3
m m TTACN
F� TO
MMFM�.M—NX
MTU F
-T
T
u
'R=3
x r m
ACT��R � NAINTA N AND �A=
STRAV TD IN- P-A EAMION �TAM.
Tl
V=
CTHE� CAN
C11,01"E
ST—�D DCT.�
'a
7/24/01 1' NT. r-
FILTER FABRIC FENCE
NTS
UT� W.
AT A� T�
mm U� TO NXNT— mm�
[lFlfl �_I�
R�.,o_
�RD D-
on --m
SHEET
PLAN
MAAwN
A�
o' To, a,
SA'N WT
cm
T SH— K.'—
om AND wTTEA .,a
7. SA�Ml RUQ*—PANTA—M
..'C;rrY.,0ED
�—DA,RD DET.L
M ;4;7
7_Z �n �AT$
CATCH BASIN PROTECTION CONCRETE SIDEWALK
NTS NTS \lty
PLAN
MAAwN
A�
o' To, a,
SA'N WT
cm
T SH— K.'—
om AND wTTEA .,a
7. SA�Ml RUQ*—PANTA—M
..'C;rrY.,0ED
�—DA,RD DET.L
M ;4;7
7_Z �n �AT$
CATCH BASIN PROTECTION CONCRETE SIDEWALK
NTS NTS \lty
1. DN Fal" ll� M11111
SOPARAMY
c" ol�`C`ANZ
To �l
W`�.
'Ir r NT
I A
A
4
TAM.
PA
PA—Ml
DETAIL A
A
4
IETAIL I
1EA 1
-4
A.
1. E TO Nt .0 MAX
.1or —S cm
I "PANSON =.m K �, 10
AND Mmmy =NTS �y 5 �.
4 UPANSON �Nn W—AW 11r . 11W
PAU� = I
U ..T �A
a SPA.,0 PT, QXAA M.N.
�— K � AND NEPT .-T
FDA 12 W�&
. — SO"". PMAM IN
MiWNAY A� SHAU K 5' -A 2' M
AT
A
AN.
AN. —
XR— _1� .-M.
77ED77,77.
I _A- PA —1 A
�TMN
NTM 0 QAAP% ON RT, THE D0 My K
c.': 1:.T.,. -y. N''
STM RD DETAL
STANDARD DE TAIL
I MIMI
CURB RAMP TYPE 4
D UlUl
T.
VERTICAL
CURB r5
CURB RAMP
TYPE 4 r6*��
NIS
11tv
NTS
SECTION E-I
"77
VIEW B-2
A Y,
Roo
T---
DETAIL A
—.7
DETAIL B —M —:gz—.jg%%m =anw -
T= AN
TO PATTEAN AS THE PAT—
T. TNE AN.
PAT— A
T. _A_
WTAX A.
L.c.-f-T—Y.
STANDARD DETAIL
RAMP DETAIL FOR TYPE 3 AND TYPE 4 RA1109
OM� 0= SN— K AD 3' IN MONT
m
ACP PA�
o
EXTRUDED CURB
NTS
AND wTTD`
ATDWWA�
�20_
a'
12
TYPE 2
A
_p
TE—ANS.
.0N.NT
G —NOT PMAM AS
IWWCrD H A,mc wA0 wox%"
wAs = w wN. —.w
P`
�ON A -A
-_v -IV
E 10
T.x
.T,
ST_D�Ro D��L
1�
7/2 NTS
RAMP DETAIL FOR TYPE 4 DRIVEWAY
NTS NTS
DRAVIN BY ULSIGNED BY 'as I APPROVED FOR CONSTRUCTION
KWP/TY A —
@ Z 2 an ,S, I
OiEa(ED BY APPROVED BY _ , dip 0mom 160J5thAm.Skel600 CITY OF EDMONDS
TJE DATE TJE [Iob*Myoudg �L. WA 93 m DATE*
206,622-SM
05/27/2015 —.kpff— 4rM4
S C A L E: lipff CITY ENGIXEDMG DIVIsION SC140y.
REMSION J 0 B No6 :114407 AS SHOWN —1 D ISTR Ic
SHERWOOD ELEMENTARY SCHOO L TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS
EDMONDS, WASHINGTON
CITY 'OF EDMONDS DETAILS
C7.01
t
6 LF 4* SO UNDER SIDEWAI K
(TYP OF 6 SPACED 20.0' O.C.)
EX SDCB f02
ADJJST FRAME AND GRADE
MM=285.50
(E-283.57
PEDESTRIAN ISLAND GRADING
CL
V02 i MW" M-= WALL I I Z;� '\ -
PER COE SM EBtZ 171!
IWO-+ -1
LIF " SO or
4%1/
-z
No�
#D4
=2 89
=27 64 M-
F, 4*
EX 12r' W - -
E 279.17 88 LF
SD- :
EX $')E-276.1 SD SIJOfl� 0
Ir I T SO SLC
00
I L
Er IE-28Z28 �277.88 SWALE AND
17+82.57.141.3 A I
F3 W/ BEEHIVE GRAIE 18+67.69, 134." RT INFIL*AIM'
STORMM RAIN YD02 TRENCH (TYP
SDCO 39 LF 01 CUTLET RIM=281-5k RM=280.i7 SEE NOTE 15
IE=280.20 so 00. E=281., ir :E=279.58�, IE=279J7
6' E=278.58
W/ SOLID
SDCB L030
RIM=2
IE= 281.63
v
A
3:1 STA 15+81 257'71'/ T J L
I
C7.0
RELOCATE FIRE HYDRAN AL-) -TC-2U5O--
ASSEMBLY PER ODE 1.
SEE NOTE 17
BC- - - - - - - - - - - - -
500 SF BDTT�!�
AREA
RN=281.70
[E=279.39±
FIELD LOCATE ON
EN SD
END SIDEWALK AN
MATCH EX GRADE
' L-
2+00
Ln
U,
rn
ri
IMYP)
2751.183
"W' 12ELBS RT
w'
RIM=277�&888
IE=277.88
LINE
106TH AVENUE
EX TEE CONNECT11
TO EX 18' SID TO
REMAIN
LF 8* SO 0 0.5%
STA �0+37.97, 128.91' RT'
ID
lagFIELD
76. EX SD
PEDESTRIAN ISLAND GRADING
SCALE:- I'= 10'
GRADING AND DRAINAGE NOTES LEGEND:
1. SEE SHEET 00.02 FOR ADD11IONAL NOTES. 6. CONTRACTOR SHALL RAJSE. LOWER ALL EXISTING UTILITY 10. REFER TO COE STD E4.Z DETAIL I ON SHEET C7.OZ FOR 15, SWALE AND INFILTRATION ON EAST SIDE OF ACCESS ROAD -281 - EXISTING CONTOUR LINE 0 FUZE HYDRANT ASSEMBLY (3/C7.02)
STRUCTURE RIMS/GRATES TO FINISHED GRADE UNLESS TYPICAL STORM DRAIN TRENCH SECTION. IS A REPLACE-4N-KIND OF THE EXISTING SYSTEM. THIS
Z SEE SHEET CO.01 FOR MASTER SITE PLAN AND OVERALL NOTED OTHERWISE. FACILITY PROVIDES STORMWATER MITIGATION FOR THE -281 - PROPOSED CONTOUR LINE N GATE VALVE
SITE CONTROL LAYOUT. 11. ALL STORM DRAIN CATCH BASINS SHALL BE TYPE I CATCH EXISTING PLAY FIELD TO THE EAST.
7. STORM DRAIN STRUCTURES SHALL BE PLACED SO THAT BASINS PER DETAIL 4 ON SHEET C3.02. sD-- STORM ORAJN LINE --I TEE
3. INSTALL A 90-DEGREE DOWNTURN ELBOW AT THE OUTLET RIMS/GRATES ARE PARALLEL TO FINISHED GRADES. 16. ALL LOCATIONS OF STORM DRAIN AND UTILITY STRUCTURES
PIPE FOR OIL CONTROL IN ALL CATCH BASINS, WITH THE 11 SEE SECTION A ON SHEET C&O3 FOR TYPICAL RAIN ARE TO CENTER OF THE STRUCTURIE. m YARD DRAIN
EXCEPTION OF THOSE LOCATED IN RAIN GARDENS. & ALL NEW PAVEMENT SHALL MEET AND MATCH EXISTING GARDEN DETAIL 17. RELOCATED FIRE HYDRANT SHALL BE INSTALLED AS A a TYPE I CATCH BASIN (7/C3.02)
WADES.
4. VERIFY ALL EXISTING UTILITY LOCATIONS AND DEPTHS PRJOR I& INFILTRATION AREAS SHALL BE FULLY PROTECTED FROM CUT -IN M THE EXISTING WATER MAIN.
TO BEGINNING CONSTRUCTION. INSTALL POLYETHYLENE 9. FIELD VERIFY SOIL CHARACTERISTICS.BELOW RAIN GARDENS ALL DELETERIOUS MATERIALS (SEDIMENT, CONSTRUCTION go- FLOW DIRECTION
PLASTIC FOAM AT UTILITY CROSSINGS IF CLEARANCE IS DURING EXCAVATION AS DESCRIBED IN THE GEOTECHNICAL DEBRIS. STOO(PHJF, ETC) AND FROM ANY CONSTRUCTION I& NOTE TO REVIEWE]t SEE SHEET C3.02 FOR IMPERVIOUS
ag LESS THAN 6 INCHES. MEMO. UNDISTURBED SOIL SUBGRADE SHOULD BE OBSERVED TRAFFIC DURING ALL CONSTRUCTION ACTIVITY. COORDINATE SURFACE SUMMARY TAME =Xx SPOT ELEVATION
BY A QUALIFIED GEOTECHNICAL ENGINEER PRIOR TO WITH NOTE 8 ON SHEET C1.01.
5. VERIFY ALL EXISTING GRADES PRIOR TO CONSTRUCTION CONSTRUCTION. IF SOIL SUBMADE IS COMPACTED DURING I& IMPERVIOUS SURFACE AREA CHART PER CITY OF EDMONDS STORM BRAIN CLEANOUT (SDCO) (5/C3.01,
ACTIVITIES. CONTRACTOR SHALL NOTIFY ENGINEER OF ANY CONSTRUCTION OR IS NOT CONSISTENT WITH THE PROPOSED 14. CENTER BLOO( WALL BETWEEN ADA RAMP AND PARIONG HANDOUT E72 PROVIDED IN DETAIL 7/C3.02. THIS
DISCREPANCIES IN EXISTING GRADE ELEVATIONS. DESIGN, EXCAVATE UNSUITABLE SOILS AND REPLACE WITH LOT. WALL SHALL BE 20' LONG (MIN� 30' HIGH (MAX� INFORMATION IS PROVIDED FOR POUT PURPOSES ONLY . ...................... . RIDGE LINE 0 10 20 40
AND IS NOT TO HE RELIED UPON FOR BIDDING OR
SELECT FILL MATERIAL AS DESCRIBED IN THE AND 50SF FACE. I k.�h - 2D W
GEOTECHNICAL MEMO. CONSTRUCTION PURPOSES. - - - - - - - SAWCUT
DRAYM BY DESIGNED BY SHEET
KWP/TY AJS APPROVED FOR CONSTRUCTfll ONL's SHERWOOD ELEMENTARY SCHOOL TRAFFId AND PEDESTRIAN SAFETY IMPROVEMENTS
call elf CITY OF EDMONDS EDMONDS, WASHINGTON
CHECKED BY APPROVED BY wo k*m dip rr lwimh�m'suk.16W
TJE TJE betm you 4 .11,�A=.
[a 0 DATE*
A I L L L 3
05/27/2015 42"4 GRADING, DRAINAGE, AND UTILITY PLAN
-.kpff- C3.01
am CITY ENGDEMG MON -SCHICOL
1 0 a No. :1144-07 FOR PERWT
NO. DATE BY CHD. APPR. ji REVISION AS SHOWN DISTRICT
0 E=4
Mi
rri
ul
m
m
4 . DRAN PIPE
C21CRETE CURB
PER RAN (TYP)
. 7\ 1 "1* 1/' . .
CONCRETE SIDEWALK J
PER PLAN
WRE ESH REINFORCEMENET 6x6 -
ME
W4.OxW4.O (4 GAUGE), 1/2-MINIMUM
COVER
:2
PLAN DUMMY JOINT
DUMMY JOINT WITH
3/16'xi-1/2' JOINT
MATERIAL (TYP)
NOTES:
1. PIPE ENDS SHALL BE FILISH WITH
FACE OF CUREL
Z Firr. INYERIS SHAU MAU wrw
6. L GUTTER LINE OR TOP OF PAVEMENT.
(TYP) I WIRE MESH SIHAUL OONFORM TO
WSDOT SID SPEC 9-07.7
SECTION A
-STORM DRAIN UNDER SIDEWALK DETAIL /�i
NTS 1\ �('
/—THREADED 01AN-OUT
4' OR 6' PER PLAN
45* BEND PERFORATED DRAIN PIPE
P p
ER PLAN
PLUG
PLAN INVERT
ELEVATION
\-WYE
STORM DRAIN CLEANOUT
NTS
FRAME. VANED GRATE AND
12* 6* CONOIETE VERTICAL an SOLID LID
PER COE SM E2.10
0
SEED TOPSOIL
'I I POR*
4' F 40 1 1 WITH FIELD MI
W R B 1E CAF TOPSOIL f, 4", 6% 12'
El PIF GEOTEXTILE TO (I ORA"' CURB DROP SIALL BE FLUSH WTH OR 24"RISER
.3H I"-
(1) #3 BAR EADi HOOP
CURB FLOW LINE TO PERMIT DRAINAGE
INTID RAIN GARDEN
z
NOTQiED CURB
4" SLOTTED DRAIN
PIPE, LEVEL ASPHALT DRIVE LANE QUARRY SPALL SPLA% PAD
GRAVEL BACKFILL FROM CURB TO BOTTOM OF
FOR DRAINS RAIN GARDEN (12' WIDTH,
!*'ALL
CURB TO
FG (I
DE'��4' DEPTH)
#3 BAR EACH CORNER
T, 72
OONCIRETE VERTICAL CMURB
PER COE SID E2.10
NOTES;-
UNOOMPACTEO RAIN GARDEN
DETAIL REFERENCED FROM RECORD DRAWINGS OF PLAYFIELD SOIL
RENOVATION (2000). REPLACE SWALE AND INFILTRATION TRENDi
IN -KIND WITH DOSTING SYSTEM AT LOCATIONS INDICATED ON PLAN. #3 BAR EACH SIDE YPICAL KNOCKOUT
W/2* MIN. WALL THICXNESS
03 BAR EACH WAY
SWALE AND INFILTRATION TRENCH NOTCHED CURB AND SPLASH PAD TYPE 1 CATCH BASIN
NTS NTS NTS
Z PIPE SHALL BE PER PROJECT SPEICIFICATIONS.
SECTION 0-
IMPERVIOUS SURFACE SUMMARY
TYPE
AREA
NON-RECULATED
3Z670 SF (0.75 AC) EX611NG IMPERVIOUS NOT DISTUR!BED
EXEMPT I
I REGULATED
REPLACED ±E�
0 SF
1
114,470 SF (0.33 AC)
(POST 1977)
1 +
114,715 SF (0.34 A(')
TOTAL REGULATED IMPERVIOUS AREA1
(MITIGATION REQUIIED IF IN EXCESS OF 2000 SF)
1 29,815 SIF (0.67 AC])
TOTAL AREA MITIGATED BY EX SFORWWATER MANAGEMENT SYSTEMS
0 SF (0 AC)
REGULATED AREA NOT YET MITIGATED
29,815 SF (OL67 AC)
AREA PROPOSIED TO BE MITIGATED BY UD TEICHNIQUES
29,315 SF (0.67 AC)
'AREA PROI TO BE MITIGATED BY CONVENTIONAL SWM TEICHNIQUES
0 SF (O-AC)
1. THIS TABLE IS INTENDED TO IDENTIFY THE EASTING (UNDWJRBED) AND PROPOSED
(NEW+REPLACED) IMPERVIOUS SURFACE AREAS FOR THE SITE. AS REQUIRED BY
CITY OF EDMONDS HANDOUT JE7Z
I AREAS IN THIS TABLE ARE ESTIMATED FROM THE DMT OF SITE IMPROVEMENTS
SHOWN ON SHEET C3.01.
3. AREAS ARE APPROXIMATE AND ARE SHOW FOR PERMITTING KNOSES ONLY.
IMPERVIOUS SURFACE SUMMARY CHART
NTS
DRAWN BY DESIGNED HT EI)NIONW SHEET
KWP/TY u A APPROVED FOR CONSTRUCTION SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS
is call 81f UTY OF EDMONDS EDMONDS, WASHINGTON
GHECKED BY W" BY two bm*m dip IC01 Rh �-, Sk. 1E00
TJE TJE rr �k..98101
Flubdonoyoudg 0 um,
I I -.kp.- C3.02
05/27/2015 4r� GRADING AND DRAINAGE DETAILS
— Wt.-
S C A IT CITY DIGNE13MG DMON SCH(OL
NO. DATE B Y CHO, APPR. REVISION J 0 B No. :11.4407 AS SHOWN DISTRICT FOR PERMIT
STORM DRAIN OUTLET PROTECTION
NTS
f
9
E
(3) SDC)0
S"'M 11 RAIN —
Ou T
%02
PRoTEjnoEN
L
BOTTOM
ELEVATION
281.08
2&1
BOTTOM
OF SLOPE
(3) 25 LF 6- DIA
SLOTTED STORM PIPE
0 O.OX 7.5' ON
TOP OF SLOPE
CENTER
RAIN GARDEN #01
SCALE- 1'=10' �, a9i
RAIN GARDEN —
PLANTING PER
LANDSCAPE PLANS
PAVEMENT OR --\
LANDSCAPE %WFACE
P)
PER PLAN (TYP)
,p) 18 if 6' DIA TOP OF SLOPE
PERF"TED
BOTTOM OF
00. 7.55' SLOPE
F F --I
6,
PROTE ON
25.0'
BOTTOM ELEVATION
276.00
(3) SDOO J NOTCHED CURB L -3 . 1
AND 91" PAD�u
RAIN GARDEN #02
SCALL- 1,=10,
TYPE I CATCH BASIN W/ SQUARE
BEEHIVE DRAINAGE GRATE (BEYOND)
PER PLAN' I
PFR PLAN
3' MULCH
6' WATER LEVEL FLAT BOTTOM S12E
AND ELEVAT16N
PER PLAN
PIPE INLET LOCATION
PER PLAN
3
18' RAIN GARDEN
GRAVEL BACKFILL
SOIL MIX
FOR DRAINS
............ ...
1-1/2- WASHED
INVERT OF OUTLET PIPE AT
BOTTOM ELEVATION OF RAIN
GRAVEL
GARDEN SOIL
4
6* CIA SLOTTED STORM DRAIN
"--WRAP WALLS IN WOVEN
GE0TE)MLE FABIaC
� I
UNCOMPACTED NATIVE
SUBGRADE
GRADING ENLARGEMENT TYPICAL RAIN GARDEN SECTION
SCAtf:- 1'=10' N TS �0.0)1
DRAWN BY DESIGNED BY ON111 SHEET
KWP/TY AJS Call 81 f APPROVED FOR CONSTRUC ON SHERWOOD ELEMENTARY SCH06L TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS
CHECICED BY APPROVED BY Rh A— �fte IRM CITY OF EDMONDS EDMONDS, WASHINGTON
TJE TJE *=MP3, 5.1., WA 98101 DATE'
DA-ff GRADING AND DRAINAGE ENLARGEMENTS
05/27/2015 C3.03
S C A lq)ff CITY ING141MG DMON SCHODL AND DETAILS
NO. DATE By CHD. APPR. RE\ASION 1 0 9 Nm :114407 AS SHOWN I Dis*rR icT FOR PERMrT
305
�00
295
290
285
280
305
300
295
290
285
280
275
305
300
295
290
285
280
30+00 30+50 31+00 31+50
50+00
REVISION
TYPICAL GRADING SECTION
SCALE- R I"=1O` V. 1"=5' ". �01
305
300
295
290
285
280
275
5D+50 51+00 51+50
TYPICAL GRADING SECTION
SCALE. H: 1*=10' V. 1'=5'
NOTE:
SECTIONS ARE TYPICAL AND INTENDED TO DIRECT
GEN]ERAL GRADING INTENT. EXACT CONDITIONS MAY VARY
IN-nELD.
RAWIN BY ULNGNLD UT EID114UNILIS SHEET
KWPI-rY AJS APPROVED FOR CONSTRUC'nON SHERWOOD ELEMENTARY SCHOOL TRWIC AND PEDESTRIAN SAFETY IMPROVEMENTS
HEou By AppRovED BT Call 811 CITY OF EDMONDS EDMONDS, WASHINGTON
to W*m dip uh A—, s, e 16m
TJE TJE bd*-M Fu d4ig s�ul.,WANIM
DATE MAW= DATE
05/27/2015 —.kW— C3.04
JOB No. :1144-07 S C A L. E: 1cpff aTY ENGREMC 1XVISON SCH(DL SECTIONS
AS SHOWN FOR PERMrr
MA)MM TREN%—
PAY WIDTH
(SEE TABLE 11
SEE STANDARD DETAIL E2.3
Q
BANK RU GRAVEL FOR
TRENCH akCKFILL
(1-1/4- MINUS) CSBC
PER COE MO
9-03.19 ORDSURABLE
EXCAVATED MATER
AS APPROVED CITY
ENGINEER (SEE NOTE
2 BELOW)
DING MATERIAL
(5/8' MINUS)
CRU ED PER
K
COE MOD
9-03 1 SA2
r a
(SEE NOTE 2
BELOW)
TABLE 1: MAX. TRENCH PATCH PAY WIDTHI
NOTE
1. IANIMUM Wl OF TRENCH AT TOP PIPE
TRENCH DEPTH MAX PAY WIDTH
36' FOR PIPE UP TO AND INCLUDING
1: 4' 40:
4 to' 60
12 - NOMIRAL DIAMETER
1. D PLUS I B* FOR PIPE LARGER THAN 12
10' 20' 72'
N�MINAL DIAMETER
—
2 REFER TO CITY OF EDMONDS MODIFICATIONS TO
DIVISION 9 OF WSDOT STANDARD
S�ECIFICATIONS. FOR MATERIAL GRADATION AND
ADDITIONAL INFORMATION.
3. TRENCH BACKFILL SHALL MEET A MINIMUM COMPACTON OF 95% DENSITY PER ASTM D 1557.
STANDARD DETAIL
I
D
TYPICAL TRENCH SECTION
090
..
-.- I— — r, -
TYPICAL TRENCH SECTION
I NTS
TYPE 'A'
ER DETAIL
2-
\2' CLASS V ACP
(TACI COIC. SURFACE 4* -518' MINUS CSTC
2' MIN SAW CUT 2-- 5/8' MINUS CSTC
NOTE:
PA MENT COMPACTION- 91% RICE DENSITY
SUBCRADE AND TOP COURSE COMPACTION - 95% (ASTM1557)
CITY INSPEITION REQUIR D ON ALL EROSION CONTRDL
MEASURES BEFORE W RK CAN BEGIN.
CURB/GUTTER FDRMS AND SUBGRAIE MSPECTION REQUIRED
PRIOR TO POURING AND BEFORE APPLYING ACP
�c- 4T.I.Y.
STANDARD DETAIL
ASPHALT WALKWAY
ASPHALT WALKWAY
NTS
PFUVATIELY OWNED BLOCK WALLS SHAI I NOT BE CONSTRUCTED IN CrrY RLO.W.
OR OVER PUBLIC EASEMENTS
'A -- � — — " �- I
Ir—
MODULAR BLOCK WALL
./,/- I— - r, - —
ED DIMENSIONING / NOTES
-MSM. 4/2/07- SCALED IMMU605 AND TEXT DOWN TO CORRECT SQ!E
MODULAR BLOCK WALL
NTS
1. FORM—AU.—UNEAN(IO—E
�y STA�
A"D OummoY
MANSII)N �75 SHALL AW 1/2' 11lr
—T
7.
FOR 72
—S—S—NO,—Outli.
SUAGRADE 03,p�
—97Y.
`-Q-F -E Q M -0 N
---4 STANDARD DETAIL
eut
CURB AND GUTTER
NTS @)
"I"Itt—AMIMIOI
irxIxzi oF
FL-
4- M V MAX
IP
v.RAITC
OD'O' TOP
eI3tAFl DA
Jul
x ILI— TA()N D— m AN
NTITF�q,
L ��A.I, I&AA
!WALZle77*#%TlTWl LOOWC PVl!oj'XlW
IIA NINT� U�Lie%�
H,�jn CtNINIT
S��
& gL4HD)M NDItE AN3)
4 I —Di NIRT ill-L FADE THE —T ON —VAT FOR
— U� � � M,
LA—
IAE H,1,MNTS — . — — — � �Y NIIIAIE
P— TO K �11 I- PAVI— IF L- M OF
TAI
STANDARD DE ? L
YDRANT ASSEMBLY
4—= RIRE H� fj
FIRE HYDRANT ASSEMBLY
NTS 9)
F I —
195
0
om
F. o
0
Q.
t5
;*1
9
ed
-
E
STANDARD DETAIL
AUMUN PEIMPRIJUll KUMRKL
PEDESTRIAN HANDRAIL
NTS
DRAVIIN BY DESIGNED BY
..S J.A4 N
KWP/TY AJS APPROVED FOR CONSTRUCTION SHERWOOD ELEMENTARY SCHOOL TRAMC AND PEDESTRIAN SAFETY IMPROVEMENTS SHEET
CHECKED BY APPROVED BY Call 81 CITY OF EDMONDS EDMONDS, WASHINGTON
TJE TJE rr 1601 Sth A—, Suite MOD
Seattle.%%" GO
DATE =Pl md �9 JL JL 14 UTE
05/27/2015 —.kpff— 4rNM, CITY OF EDMONDS DETAILS C7.02
— S C A I E' CITY ENGREMC DIVISON SC[4(DL I
NO. DATE APPR. RE\ASION JOB No. :114407 AS SHOWN DISTR lC-fI FOR PERMIT
I
Appendix G
Geotechnical Engineering Memorandum
I
I
I
I
I
� I
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
� I Appendix G
I
Golder
As
saloates
TECHNICAL MEMORANDUM
Date: April 15, 2015 Project No.: 1526711
To: Thaddeus Egging Company: KPFF
Alex Sundell
From: Deb Ladd, PE, LHg
James G. Johnson, LEG
cc:
RE: SHERWOOD ELEMENTARY SCHOOL — INFILTRATION EVALUATION
This memorandum provides technical information to support infiltration design for proposed stormwater
management options related to traffic improvement options at Sherwood Elementary School in Edmonds,
Ih
Washington. Sherwood Elementary School is located southeast of the intersection of 228 Street SW and
60t' Avenue W in south Edmonds. Golder Associates Inc. (Golder) services were provided to KPFF,
'working for the Edmond School District (District).
1.0 PROJECT UNDERSTANDING
Current project plans include new.impervious surfaces related to expanded parking areas and a new
entrance drive from the north part of the school at 228t' Street SW. Stormwater infiltration facilities are
planned near the northwest part of the site and along the west edge of the playfield. These infiltration
features are shown in Figure 1, south of test pit GTP-03 and near test pit GTP-04. The infiltration facilities
have subgrades approximately 5 feet (ft) below current grades and include 1 Y2 ft of rain garden soil over
2 1/2 ft of gravel.
2.0 SURFACE AND SUB8URFAdE CON D*ITIONS
Golder's observations during site visits and investigations are summarized in this section along with results
from laboratory testing of soil samples.
2.1 Site Surfacci-ObserVatl,ont
A site visit was conducted on March 25, 2015 for a brief reconnaissance and exploration planning; we
completed a second visit on March 30, 2015 to complete test pit excavations. Native soils were observed
in small exposures on the slopes on the east side of the school. These soils consisted of layered sand with
variable silt content estimated to range from less than 5 percent to about 15 percent. No seepage was
observed from the slope. Geological mapping (Minard 1983) shows the school as underlain by Vashon-
age advance outwash, that typically consists of sand and gravel with variable silt.
041415dll Sherwood Infiltralion Rate TM.Docx
Golder Associates Inc.
18300 NE Union Hill Road, Suite 200
Redmond, WA 98052 USA
Tel: (425) 883-0777 Fax: (425) 882-5498 www.golder.com
Golder Associates: Operations In Africa, Asia, Australasia, Europe, North America and South America
r,nlelor rnlripr A%�nriwpr nnrl thp ('A ninhA rl��inn wp IrAel�mnrkc nf (' —War A�nriwac r.nmnrA11^n
Thaddeus Egging April 15, 2015
KPFF 2 1526711
During both site visits in March, Golder observed that there were no areas of standing water on the site,
except for very small puddles where foot traffic was heavy. The playfield area was very well drained and
there was no evidence of rutting or saturated soil subgrade. The District's maintenance personnel reported
that they do not have any problems with drainage at the school. In addition, there was no standing water
observed in stormwater ditches / swales along public roadways around and close to the school.
21 TerA Pits
Golder completed five test pits near the planned infiltration facilities on March 30, 2015. During the test
pits, we documented soil and groundwater conditions and acquired select soils samples for laboratory soil
testing. The test pits, identified as GTP-01 through GTP-05, were excavated with a rubber -tired backhoe
provided by the Edmonds School District at the approximate locations shown in Figure 1. Exploration logs
are provided in Attachment A. Golder's explorations were completed under full time observation of a
geotechnical engineer / hydrogeologist. The test pits were excavated to depths between 4.5 to 8.3 feet
below ground surface (bgs).
During the explorations, soil samples were classified in the field. Pertinent information, including sample
depths, stratigraphy, soil consistency, and groundwater occurrence was recorded in the exploration logs.
The stratigraphic contacts indicated on the exploration logs represent the approximate boundaries between
soil types; actual transitions might be more gradual. The soil and groundwater conditions depicted are only
for the specific dates and locations reported and are not necessarily representative of other locations and
times.
2.3, Laboratory Te.sting
Geotechnical laboratory tests for grain size distribution and moisture content were conducted on select
representative samples to characterize engineering and index properties of the soils. A summary of test
results is provided in Table 2.1. All laboratory testing results are presented in Attachment B.
041415dll_Shen�ood Infiltration Rate TM.DoCx
ciatts
Thaddeus Egging April 15, 2015
KIPFF 3 1526711
Table 2.11: Laboratory Testing Summary
Exploration
usc�i
Moisture
Fines
Sand'
Gravel
Dio
Dro
D90
Location and
Observed
6ritent
.(0/.)?
N3
(�/.)4
(mm)
(mm)
(mm)
sample
Soil Unit
M
Dq�pth
.,GTIP�-011
S�m
-4.0 ft
Fill
17.0
17.5. .1
79.3
3.2
0.01
.0.36
0.85
jSTP-01
SIP-SIVI
5.0 ft,
Native
9.3
9.5
79.3
1 1.�
0.08
0.43
6
GTP-02
SP-SM
0.5 - 3.0 ft
Fill
7.6
6.1
61.8
1 32.1
0.13
1.98
11
'GTP-02
SP-SM
�5.0 - 6.0 ft,
Native
8;_0
6.9
82.4
10.7
0.10
6;39
6
OTP-04
SP7SIVI
2.0.- 3. 0 ft
Fill
1 Q.4
10.9
75.3
13.8
0.07
0.46
8
6TP-04
Sm
7.5 - 8.0 ft
Native
17.3
16.4
73.1
10.5
0.04
0A1
5
GTP-05
SRSIVI
1.0 - 2.0 ft
Fill 1
12.0
11.2
72.7
16.1
0.065 1
0.52 1
10
GTP-05
SP-SM
3.0 - 3.5, ft
Fill
9.'6
10.1 1
70.9 1
1 9.Q
0.075
0-55
1"
Notes:
I . See Attachment A for information on USCS soil type.
2. Fines content is portion less than the U.S. No. 200 sieve, by weight
3. Sand is the portion of material pass the U.S. No. 4 sieve and retained on the U.S. No. 200 sieve
4. Gravel and larger sized is the portion of material retained on the U.S. No. 4 sieve
5. DIO extrapolated from sieve analysis where greater than 10% fines
2.4 Subsurface -Conditions
Observed subsurface soil conditions included a thin layer of 'topsoil' with sod, underlain by a variable
thickness of fill and native glacial outwash, deposits.
Topsoil: A thin layer of loose silty sand with organics and sod was observed in all test pits. The topsoil
was observed to range from about 0.5 to 1.0 feet thick.
Fill: Fill was observed in all test pits to depths of between 3.5 and 4.0 feet bgs. The fill was generally
similar to the native soil in the test pits and the native soil cut slopes that were observed on the east side
of the school. The fill typically consisted of a fine to coarse or fine to medium sand with some silt and
variable gravel. Typical USCS classification was an SP-SIVI, reflecting greater than 5 percent to less than
12 percent fines. Some of the fill observed was cleaner (less silt) or dirtier (more silt) than an SP-SIVI
classification.
Native Glacial Soil: Interpreted native glacial soil was observed at all test pit locations. The observed native
soil typically included a siltier upper soil horizon that appeared to be the partially stripped topsoil horizon
from pre -development grades. Th is soil horizon was underlain b y a fine to coarse or fine to medium sand
&,iaol4er
Thaddeus Egging April 15, 2015
KPFF 1526711
with some silt and variable gravel (e.g., SP-SM), similar to soils that were observed in the fill layer. At
GTP-04, silt layers were observed in the native soils, but these layers were not present at other test pits
and are interpreted to be discontinuous.
1.5 6bserved Groundwater Conditions
Seepage from a perched layer was observed at one test pit, GTP-01, in a clean sand on top of the native
old topsoil horizon. The seepage was low and interpreted to likely be associated with a nearby closed drain
system. The soils beneath the native topsoil horizon were moist, not saturated. Seepage was not observed
in any other test pits. There will likely be fluctuations in quantities of seepage depending on the season,
amount of precipitation, surface water runoff, and other factors.
To estimate groundwater levels near the planned infiltration facilities, Golder researched the Washington
Department of Ecology's online well log database. At a domestic well, about !/4mile west (and downhill) of
the school on North Deer Drive, groundwater was reported at 20 feet bgs. From this information, we
interpret groundwater at the infiltration facilities is at least 20 feet below the ground surface.
3.0 INFILTRATION
This section of the report provides conclusions about the suitability of subsurface conditions for stormwater
management related to the planned site development. Based on our subsurface explorations, infiltration
approaches are suitable for stormwater management for future land development. Key findings:
• Subsurface conditions are relatively uniform across the areas explored, with most soils
-providing moderate infiltration potential. Lower permeability soil layers could be present,
but they are expected to be discontinuous so that infiltration will still occur.
• Test pits closest to the planned infiltration facilities (GTP-01, GTP-02, and GTP-03) showed
suitable soils for infiltration.
• Groundwater is estimated to be greater than 20 feet below the base of a potential infiltration
facility
3.1 Infiltration besigfn
Subsurface conditions at explorations in key locations were evaluated to identify soil and groundwater
conditions for potential infiltration. Golder evaluated infiltration rates based on the USDA Soil Textural
Classification procedure on Table 3.7 and the ASTM Gradation Testing procedures provided on Table 3.8
in Ecology 2005. The USDA procedure is the same as in Edmonds' Stormwater Code Supplement
(Edmonds 2010). Golder also evaluated infiltration rates using the "Soil Grain Size Analysis Method", page
3-79, Ecology 2012. Table 3-1 presents long-term design infiltration rates based on the Ecology 2005
Edmonds 2010 approaches.
041415cill—Sherwood Infiltration Rate TM.Docx
WAssociates
Thaddeus Egging
KPFF 5
Table 3-1: Long -Term Design Infiltration Rates - 2005 Ecology Methods
April 15, 2015
1526711
Long Term
Long Term
4
Design Rate
Exploration
Fines
DIO
Design Rate
Location and
Sample:Depth
USCSi
USDA
(0/0 2'
(mm)
Using USDA
ASTM
Gradation
Textural
Textural
Testing
Class
Class (in/hr)
(in/hr)
6f P-01
SM
Loamy
4.0 ft
Fill
Sand
17.5
0.015
0.5 .
<0 .8
GTP�-O!
SP-Sm
5.0 ft
Native
Sand
9.5
0.08
1 2
1.0
GTR-N
SP7SM
0.5 - 3.0 ft
Fill
Sand
6.1
0.13-
Z
2.0
GTP-012
-SP-SM
5.0 - 6.0 ft
Native
Sand
6,.9
010
2
2.o
GTP-64
SP-SM
Loamy
2.0 - 3.0 ft
Fill
Sand
10.9
0.07 5
0.5
1.0
GTP-04
SM
Loamy
7.5 - 8.0 ft
Native
Sand
16.4
.0.04 5 1
0.5
<0:8
GTP-05
SP-SM
Loamy
1.0 - 2.0 ft
Fill
Sand
11.2
0;0655
0.5
0.8
GTP-05
SP-SM
3.0 - 3.5 ft
Fill
Sand
10.1 1
0.075
2.
1.0 1
Notes:
'USCS = Unified Soil Classification System
2Fines content is portion less than the U.S. No. 200 sieve, by weight
31-ong-term design infiltration rate based on USDA textural class as provided in Table 3-7, Ecology 2005 and Table
C-11, Edmonds 2010
41-ong-term design infiltration rate based on D10 size from laboratory testing as provided in Table 3-8, Ecology 2005
5D 10 extrapolated from sieve analysis
mm millimeter
in/hr inches per hour
Table 3-2 below presents calculated saturated hydraulic conductivity (Ksat) and long-term design infiltration
rates based on sieve analyses from tested soils based on the procedure in Ecology 2012. The long-term
design infiltration rates are based on a total correction factor, CFT of 0.15. This correction factor (higher
factor of safety) is based on guidance in Ecology 2012 and is based on the assumption that some of the
deeper soils are likely glacially overconsolidated.
I
n.11A11,,111 Ah�11 P.t. ThA rW.�
A111-MA
- I
if "r. G014er
%WAsgodates
Thaddeus Egging April 15, 2015
KPFF 6 1526711
Table 3-2: Long -Term Design Infiltration Rates - 2012 Ecology Method
Long
Ekploration
'Uscsi
Fines
D10
D6o
Dqo
Ksat
Term
L6tat�qn and
Obs'6 rve'd
(0�6)1
(mm)
(mm)
(mm)
(in/fir)
Design
�amplle Depth
Soil Unit
Rate3
(in/hr).
GTP-61
sm
4.0.ft-
Fill
17.5
0.6 1 14
b,136
0.85
17.0
2.6
GTP�0111'
sp-w
5.0 ft
Native
9.5
0.08
.0.43
6
29.1.
4.4
GTP-'02
SP-SM
0.5 - 3.0 ft
'Fill
6.1
0.13
1-98
11
38.'8
5.18
GTP-02
SP-sm
.5.0 - 6,0 ft
Rative
6.9
0.10
0.39
6
36.0
5.4
GTP-04
sp-sm
3.0 ft
Fill
10.9
0.071
0,46
8
24.2
16
6TP.'-'04
sm
7.5-- 8.0 ft
Native
16.4
0.04 4
0;A1
5.
18.1
2.7
GTP'-05
sp�sm
1.0 - 2.0 ft
Fill
11-21 _L
Q.A65 4
0.152.
IQ
22.4
�A
GTP'05
SP-8m,
3.0 - �., ft
Fill
10.1
[ 0.075
0:55
10
3.7
Nptes:
1UStS = Unified Soil Classification System
21Fines content is portion less than the U.S. No. 200 sieve, by weight
31-ong-term design infiltration rate based on fines %, D1 0, D60, and D90 size from laboratory testing as provided on
page 3-79, Ecology 2012
IDIO extrapolated from sieve analysis
mm millimeter
in/hr inches per hour
Based on the results of testing and the observed soil stratigraphy, Golder recommends using a long-term
design infiltration rate of I in/hr.
3.2 Othe.r.1hfi1t.ebi_t1bn C- onsideratio-n's
Ecology's manuals for stormwater facility design also include site suitability criteria (SSC) that need to be
evaluated for infiltration suitability. Applicable SSC are summarized below.
0 SSC-1 - Setback Criteria. Stormwater facilities must be at least 100 ft from drinking water
wells, septic tanks, and drainfields. All planned facilities are greater than 100 ft from these
features.
• SSS-2 - Groundwater Protection Areas. There are no specific groundwater protection
areas underlying the infiltration facilities.
• SSC-4 - Soil Physical and Chemical Suitability for Treatment. Based on site observations
and laboratory testing, the soils are considered suitable for stormwater treatment, if
needed.
Gol&r.
041415dll SherwDod InfiltrOtion Rale TM.00cx Aies
,Thaddeus Egging April 15, 2015
KPFF 7 1526711
0 SSC-5 — Depth to Bedroc_k Water Table, or Impermeable Laver. Based on a domestic well
log near the facility, the water table is estimated to be present at 20 feet or deeper beneath
the infiltration facilities. Low permeability soil was observed at the base of one test pit and
may be present beneath the infiltration facility at depths greater than 8.3 ft, the limit of test
pit observations. Based on the depth limits of the test pits, infiltration facilities with planned
subgrades deeper than about 5 ft below current grades may require additional
investigation-
3.3 Construction
Infiltration facilities can be adversely affected by sediment -laden water routed to the facility during
construction. Poor erosion and sediment control practices during construction has the potential to
permanently lower infiltration rates. Accordingly, the planned infiltration features should not be used for
stormwater control during construction, In addition, Golder recommends that the stormwater facility
subgrades not be excavated until these features are ready to be fully constructed.
The undisturbed soil subgrade should be observed by the geotechnical engineer (or their representative)
prior to construction of the stormwater facilities. The geotechnical engineer should asses if subgrade
conditions are consistent with the proposed design, Because overcompaction of subgrade soils can reduce
infiltration capacity, heavy equipment should not operate within a stormwater feature.
For the assumed design infiltration rates, subgrade conditions should include at least 3 feet of suitable
infiltration soil beneath the facility subgrade or a select fill soil. Based on the explorations at the site, low
permeability soils could be present in discontinuous layers or lenses at planned facilities. These soils, if
encountered at facility subgrades, will require removal and replacement. Accordingly, Golder recommends
that a small pit be dug to about 3 ft below the infiltration facility subgrade at the time of construction to
determine if low permeability layers or lenses are present.
If existing subgrade soils are removed to improve infiltration, the soils should be replaced with select fill
containing 7 percent or less material passing the US No. 200 sieve by weight.
4.0 SUMMARY AND CLOSURE.
Observations during late March 2015 showed the ground surfaces to be well drained, indicating generally
suitable soils for infiltration. Soils (fill and native soils) observed in test pits are generally suitable for
infiltration, but there is some variability. To address the observed soil variability, a conservative estimate
of infiltration rate has been used for design. In addition, this memorandum recommends that observations
should be completed during construction to allow for replacement of soils that do not have the infiltration
capacity assumed for the design.
Golder
Thaddeus Egging April 15, 2015
KPFF 1526711
We trust this memorandum meets your needs. Please contact the undersigned if you have additional
questions,
�Deborah Ladd, PE, LHg
Senior Project Engineer
Attachments or Enclosures�
Figure 1 Site Plan
Attachment A Test Pit Logs
Attachment 6 Laboratory Testing Results
DL/JGJ/km
)a_� i Y-O�
James G. Johnson, LEG
Principal
0414 1 5dI I —Sherwood Infiltration Rate TM.Docx
Gol&r
kssodittes.
Thaddeus Egging April 15, 2015
KPFF 9 1526711
5.0 REFERENCES
Department of Ecology (Ecology). 2005. Stormwater Management Manual for Western Washington.
Prepared by the Washington State Department of Ecology Water Quality Program. February.
Ecology. 2012. Stormwater Management Manual for Western Washington. Prepared by the Washington
State Department of Ecology Water Quality Program. August.
City of Edmonds (Edmonds) 2010. Exhibit A, Stormwater Code Supplement to Edmonds Community
Development Code Chapter 18.30. April.
Minard, James P. 1983. Geologic Map of the Edmonds East and Part of the Edmonds West Quadrangles,
Washington. United States Geological Survey. Miscellaneous Field Studies Map MF-1 54 1.
041415dli Sherwood infiltration Rate TM.Docx
Q
I a [till all
F FkSh,:v.',oWt—Ant%p_PR0ZZCT�%l 52,17 1 1—i�finmi.onS[,YJ,',NOIO:—P.RODUCTIO 'PJNDD�l 5267 1 1000_0101J�dd
%
- - - - - - ;
106TH AVE. W
inn
r
OW ml
NGTP-05
44 P�-
all
ti;
GTP-02
4p
'7 4-f
T'
..... ..... OLL, r 9 GTP-04
rw". f
ev
ur'
aL'.r %L
-T 4 m
m
;74
T
pv 54 % j �T..l
(9A, M094t
two", ry
A 04A
MIND m
r. ,-% uh
--- 8 -
?j
41
4t�
IPI lw"�
L
4$�
SOURCE: SITE SURVEY KPFF MARCH 2015
CLIENT
KPFF
CO NSULTANT
W GoMer
Assodates
yyyy-FAII-1-Do 2015-04-15
PRE��-\RED A.PARKIN
DESIGN
REVIEW
NOT TO SCALE
LEGEND
-$� GTP-03 APPROXIMATE LOCATION OF GOLOER TEST PITS
PROJECT
SHERWOOD ELEMENTARY SCHOOL INFILTRATION EVALUATION
TITLE
SITE PLAN
PROJECT.No.
1526711
��PPROVEQ
60
ATTACHMENT A
TEST PIT LOGS
a3
La
zi
W
0
(VGolder LOG OF TEST PIT GTP-01
�Associates
Temp 60 *F Weather sunny, cool Engineer D. Ladd Operator Rick
Equipment Case rubber -tired backhoe Contractor ESD Date 3-30-2015
Elevation 0.0 ft Datum NA Job 1526711
Location West side playfield
0
0.0 2.5 5.0 7.5 10.0
-0.0
.5
Bc
7.5
10.0
A
B
C
E
ft
ttom of Test Pit at 6.0
A 0.0 - 1.0 ft: (SM to SP-SM), fine to medium SILTY SAND
to fine to medium SAND some silt, some
gravel; red -brown; rooted zone 4 inches; moist,
loose to compact (FILL)
B 1.0 - 3.0 ft: (SP to SP-SM), fine to medium SAND to fine
to medium SAND some silt, some gravel; tan to
gray in layers; moist, loose to compact (FILL)
C 3.0 - 3.8 ft: (SP), fine to medium SAND some coarse
sand; gray; moist to wet, compact (FILL)
D 3.8 - 4.5 ft: (SM), fine to medium SILTY SAND, some
gravel; brown; trace old roots; moist, loose to
compact (OLD TOPSOIL)
E 4.5 - 6.0 ft: (SP to SP-SM), fine to medium SAND to fine
to medium SAND some silt, some gravel;
red -brown to tan; moist, compact (NATIVE
SOIL)
0
SAMPLES
NO.
DEPTH
(ft)
% MOISTURE
S-1
4.0
17
S-2
5.0
9.3
SUMMARY OF LABORATORY TESTS'
SAMPLE % GRAVEL % SAND % FINES
DEPTH (ft)
4 3.2 79.3 17.5
5 11.2 79.3 9.5
SPECIAL NOTES:
Very minor seepage at 3.5 ft bgs
6�0'
Golder LOG OF TEST PIT GTP-02
ociates
Temp 60 'F Weather sunny, cool Engineer D. Ladd Operator Rick
Equipment Case rubber- Fire—d'6—ackhoe Contractor ESD Date-3-30-2015
Elevation 0.0 ft Datum NA Job 152671.1
Location NW end playfield main infiltration
1 r____ I T--] 0
0 —,1
0.0 2.5 5.0 7.5
10.0
SAMPLES
—0.0
A
NO. DEPTH % MOISTURE
B
S-1 0.5 7.6
S-2 5;0 8
—2,1
C
L
—5.0
E
7.5
Bottom of T st Pit at 7.5 ft
LITHOLOGIC DESCRIPTIONS AND EXCAVATION NOTES
SUMMARY OF LABORATORY TESTS
A 0.0 - 0.5 ft: (SM), fine to medium SILTY SAND, some
gravel- brown- with roots / sod-, moist, loose to
compact (FIE)
ONEL
% SAN��
FINES
0.5
32 1
61.8
6.1
B 0.5 - 3.5 ft: (SP, SP-SM, to SM), fine to medium SAND,
5
10.7
82.4
-
fine to medium SAND some silt, to fine to
medium SILTY SAND, some gravel; tan to gray
in layers� moist, loose to compact (FILL)
C 3.5 - 4.0 ft.- (SM), fine to medium SILTY SAND, some
gravel; red -brown; moist, loose to compact
(NATIVE SOIL)
D 4.0 - 4.5 ft: (SP-SM), fine to medium SAND some silt,
some gravel; brown; moist, compact (NATIVE
SOIL)
SPECIAL NOTES:
No seepage
E 4.5 - 7.5 ft� (SP-SM), fine to medium SAND soern silt,
some gravel, some coarse sand; gray; moist,
compact (NATIVE SOIL)
tw'Golder' LOG OF TEST PIT GTP-03
Temp 60 * F Weather sunny,cool Engineer D. Ladd Operator Rick
Equipment Case rubber -tired backhoe Contractor ESD Date 3-30-2015
Elevation 0.0 ft Datum NA Job 1526711
Location West side playfield
0 11 111 0
0.0 2.5 5.0 7.5 .0
-U.V
7.5
0.0
A
B
T-C _F_
ttom of Test Pit at 4.5
ft
A 0.0 - 0.8 ft: (SM), fine to medium SILTY SAND, some
gravel; brown; with roots / sod; moist, loose to
compact (FILL)
B 0.8 - 4.0 ft: (SP, SP-SM, to SM), fine to medium SAND,
fine to medium SAND some silt, to fine to
medium SILTY SAND, some gravel-, variably
tan to gray; moist to near wet at 4 ft, loose to
compact (FILL)
C 4.0 - 4.5 ft: (SM), fine to medium SILTY SAND, some
gravel; red -brown; moist, loose to compact
(NATIVE SOIL)
NO. I DEPTH % MOISTURE
AM6
C
(FGolder LOG OF TEST PIT GTP-04
Associates
Temp 60 *F Weather -sunny, cool_ Engineer D. Ladd Operator Rick
Equipment Case rubber -tired backhoe Contractor ESD Date-3,30-2015
Elevation 0.0 ft Datum NA Job 1526711
Location NW end pla�Aield main infiltration
0
0.0
-0.0
2.5
-5.0
-7.5
Bottom
.-10.0
0
2.5 5.0 7.5
-i-T---�
10.0
A
SAMPLES
NO.
DEPTH
(ft)
% MOISTURE
S-1
2.0
10.4
S-2
7.5
17.3
C
D
E
I
-
F'
ft
of Test Pit at 8.0
LITHOLOGIC DESCRIPTIONS AND EXCAVATION NOTES
SUMMARY.OF LABORATORY TESTS
A 0.0 - 0.5 ft.- (SM), fine to medium SILTY SAND, some
gravel- brown; with roots / sod,- moist, loose to
compact (FILL)
B 0,5 - 4.0 ft: (SP-SM, to SM), fine to medium SAND some
silt, to fine to medium SILTY SAND, some
gravel- tan to gray -brown; moist, loose to
compact (FILL)
C 4.0 - 6.0 ft: (SP-SM), fine to medium SAND some silt,
some gravel; brown; moist, compact (NATIVE
SOIL)
D 6.0 - 6.5 ft: (ML), sandy clayey SILT,- layer not
continuous; light tan-, moist, very stiff (NATIVE
SOIL)
E 6.5 - 7.5 ft: (SP-SM), fine to medium SAND some silt,
some gravel, occasional boulders; brown. -
moist, compact (NATIVE SOIL)
F 7.5 - 8.3 ft: (ML), sandy SILT; decayed root pieces- dark
red -brown: moist, compact (NATIVE S61L)
LE
jDEPqTH(ffl
('
%GRAVEL
%SAND
WFINES
2
7.5
13.8
75.4
10.5
73.0
16.4
SPECIAL NOTES:
No seepage
� Golder LOG OF TEST PIT GTP-05
Assodates
Temp 60 OF Weather sunny, cool Engineer D. Ladd Operator Rick
Equipment Case rubber -tired backhoe Contractor ESD Date 3-30-2015
Elevation 0.0 ft Datum NA Job 1526711
Location On Berm near W drive
0 1 1 1 1 1 1 1 1 1 -TT—F-1-1 - I I 1 1 1 —7- 0
0.0 2.5 5.0 7.5 J. 0
-0.0
A
-2.5
B
C
-5-§ottom
of Test Pit at 3.5
-7.5
-10.0
LITHOLOGIC DESCRIPTIONS AND EXCAVATION NOTES
A 0.0 - 0.5 ft: (SM to SP-SM), fine to medium SILTY SAND
to fine, to medium SAND some sily, some
gravel; brown; with roots / sod; moist, loose to
compact (FILL)
B 0.8 - 4.0 ft: (SP-SM, to SM), fine to medium SAND some
silt, to fine to medium SILTY SAND, some
gravel; red -brown; moist to near wet at 4 ft,
loose to compact (POSSIBLE FILL)
C 4.0 - 4.5 ft: (SP-SM), fine to medium SAND some silt,
some gravel; gray -brown; moist to near wet at
4 ft, loose to compact (NATIVE SOIL)
I
I [
SAMPLES
NO. DEPTH % MOISTURE
(ft)
S-1 1.0 12
S-2 3.0 9.6
SUMMARY OF LABORATORY TESTS
SAMPLE
DEP`rH (ft)
% GRAVEL
% SAND
% FINES
1
16.1
72.7
11.2
3
19.0
70.9
10.1
SPECIAL NOTES:
No seepage
0
ATTACHMENT B
LABORATORY TESTING RESULTS
ZI
P1526711
PARTICLE SIZE DISTRIBUTION
ASTM D421, D422,1)4318
PROJECT NAME: Sherwood Elementary
SAMPLE JD: GTP-01 S-1 Depth: 4 ft
TYPE:
oil
I
N
I
11111
NO
E11111
1111
llilimillill
11
1000
I[.. .
100
10
1 0.1
Particle size in millimeters
0.01 0.001
COBBLES
co.m
Fine
C-.c M.M. Fin,
S'llo'clay
GRAVEL
SAND
FINES
F-1
12.0-
Particle Size Particle Size
(vnm) % Passing Classification Percentage
304.8 100.0
Moisture Content
La
d)
D
E
M
Z
(13
U)
'2
Cobbles
0.0
6.0"
154.2
100.0
3.0"
75
100.0
2.5"
63.5
100,0
Coarse Giavel
0.0,
1.01,
50
100 , 0
1.51,
37�5
100.0
1.0"
25
100.0
0,75"
19
100.0
0.375"
9.5
100.0
Fine Gravel
3.2
04
4.75
96.8
#10
2.00
94.1
Coarse Sand
2.7
420
0.85
89.1
Medium Sand
24.5
#40
0.43
69.7
#60
0.25
37.6
Fipe Sand
.52.2
#100
0.15
21.5
4200
0.075
17.5 1
Fiacs ' 17.5
D.= 0.36 D30-- 0.20 Dl()= #N/A
C, - D6011) 10 - #NfA #N/A
cc - D30-'2/(D 10*060) #N/A #N/A
DESCRIPTION: Silty F-C SAND
trace fime gravel
USCS: Sm I
TECH TPM
DATE 3/31/15
CHECK TCM
REVIEW DL
V31/15
PARTICLE SIZE DISTRIBUTION
ASTrvl ))421, D422, D4318
PROJECT NAME: Sherwood Elementary
SAMPLE ID: GTP-01 S-2
TYPE:
Depth: 5 ft
P1526711 I
milli
0
1
IN
I
I
I
HE
1111111111
IN
Nil!
120
E
Z
Z
14
GRAVEL
Particle Size Particle Size
12.0"
304.8
100.0
Cobbles
0.0
6.0*
154.2
100.0
3.0"
75
100.0
2.5"
63.5
100.0
Coarse Graei
0.0
2.0"
50 1
)00.0
1.51,
37.5
00.0
1.01,
25
100.0
0.75"
19
100.0
0,375"
9.5
91.8
Fine Gi,a�el
11.2
#4
4�75
88.8
410
2.00
84.4
Coa)sc Sand
4.4
#20
0.85
78.2
Medium Sand
24.7
440
0.43
59.7
#60
0.25
3L8
Fine $and
50.2
#100
0.15
1955'
4200
0.075
Fines 9.5
DGO= 0.43 D�0= 0.24 D10= 0.08
ICu - D60/D10 5.4
Cc - D30'21(010*D60) 1.6
DESCRIPTION: F-C, SAND
soinc fime gravel, sonie silt
13SCS: SP-Sm I
FINES
Moisture Content
TECH TPM
DATE 3/31/15
CHECK TC?V!
tEVIEW l)L
PARTICLE SIZE DISTRIBUTION
ASTM D42), D422,1)4318
PROJECT NAME: Sherwood Elementary
SAMPLE ID: GTJP-02 S-1
TYPE:
Depth: 0.5 ft-3.0 ft
P1 5267111
12" 3' 2' 1- 3/4- 18" #4 910 #20 #40 #60 #100 #200
100
11-
1 N,
90
80'
% 70
P
60
a
50
40
n
30
20
10
0
1000 100 10 1 0.1 0.01 0,001
Particle size in millimeters
coa,se Fine
COBBLES GRAVEL
Cwnc
Med- Fine
SAND
silt.'My
FfNES
12.0"
Particle Size
jmm)
304.8
Pailicle Size
% Passing Classification Percentage
100.0
moisture Content
E
:3
Z
r
U)
Cobbles
0.0
6.0"
154.2
100.0
3.0"
75
100.0
2.5"
63.5
100.0
Coarse Gravel
11.6
2.0"
50
100.0
-1.5"
37.5
10000
1.01,
25
100.0
0.75"
i9
88.4
0.375'
9.5
77.2
Fine Gi 3vel
20.5
#4
4.75
67.9
#10
2.00
60.1
Coarse, Sand
7.8
#20
0.85
52.4
Mcclition Sand
1 21.5
0.43
38.6
-#40
#60
0.25
21.5
Fine Sand
32.5
1 #100
1 0.15
1 1 1 *0
#200
1 0.075
6.1
Fines 6.1
D,= 1.98-----F-D,,= 0.33 01,= 0,13
Cu D601D 10 15.2 6
Cc D30'2/(DtO*D60) - 0.4
DESCRIPTION: Gravelly F-C SAND
soine silt
TECH TPM
oscs: SP-SM DATE 3/31/15
CHECK TCW,
REVIEW OL
V31/15 PI 526711
PARTICLE SIZE DISTRIBUTION
ASTM D421, 0422, D4318
PROJECT NAME: Sherwood Elementary
SAMPLE ID: GTP-02 S-2 Depth: -5.0 I't -6.0 ft
TYPE.
IN
11
11
1
IN
IN
1111
11
01
1111111
1
11
11
IN
11
IN
111111101
11
1
IN
0
1
1111
ON
III
coal -se I Hite C.�rsc Klediurn I Fine SiliorClay
COBBLES � GRA\ EL SAND I FINES
E
Z
Z
'a
c:
Q
U)
Parricle Size Panicle Size
-I p ....... CI-ifi,-..
12.0"
304.8
100.0
Cobbles
0.0
6.0"
154.2
J00.0
3.01,
75
100.0
2.5"
6M
100.0
Coarse Gra,,el
5.4
2.0"
50
IOU
1.51,
37,5
100,10
1.01,
25
100.0
0,75"
19
94.6
0,375"
9.5
92.0
Fine Gravel
5.3
#4
4.75
89.3
410
2.00
86.7
Coarse Sand
2.6
#2 0
0.85
82J
Medium Sand
22.2
#40
0.43
64.5
#60
0.25
34.0
Fine Sand
57.6
4100
0.15
15.0
9200
0,075
6.9
Fines 6.9
060= 0.39 D30= 0.22 D,,,= 0.10
Cu-D60/D1()= 4.0 6
Cc = D30^2/(I)I0'D60) 1.3 1
DESCRIPTION: F-C SAND
sorne fine gravel, sornee silt
USCS: Sp-Sm
MCISJUTC Conient
TECH
TPM
DATE
3/31/15
CHECK
Tcm
REVIEW
DL_
1/15 P1526711
PARTICLE SIZE DISTRIBUTION
ASTM D421,1)422, D4318
PROJECT NAME: Sherwood Elementary
SAMPLE ID: GTP-04 S-1 Depth: 2.0 ft-3.0 ft
TYPE:
12- 3* 2' 1" 314" 3/8' #4 #10 #20 #40 #60 #100 #200
100
NJ
90
80
% 70
P
60
50
I A
I
I
I
40
n
9
30
20
10
0
1000 100 10 1 0.1 0.01 0.001
Particle size in millimeters
COBBLES
CO- FiW
C oarse
1Adi- Fin,
Silt 0, Clay
GRAVEL SAND
FINES
F� 12.0"
Particle Size
(MM)
304.8
Particle Size
% Passing Classification PeTCCFn3gC
)G0.0
Moisture Content
120
E
Z
'a
r
4
'2
to
0
Cobbles
0.0
6.0"
154.2
100.0
3.0"
75
100.0
2.5"
63.5
100.0
Coarse Gravel
0.0
2.0"
50
100.0
1.51.
37.5
100.0
1.011
25
100.0
0.75"
19
100.0
0.375"
9�5
91.5
rine (iravel
13.8
4
#4
4.75
86.2
410
2.00
79.8
Coarse Sand
6.4
g#
#20
0.85
72.8
Medium Sand
1 21A
#40
0.43
58.4
060
0,25
35.1
Fine Sand
1 47.5
9100
0.15
18.4
,*200
0.075
10.9
Fines 10.9
D60= 0.46 D,,= 0.21 D10= #NIA
Cu = D60/D 10 #NIA IN/A
Cc - D30'21(D 10*D60) #N/A #N/A
DESCRIPTION: Gravelly F-C. SAND
Some silt
USCS: Sp-Sm
TECH TPM
DATE 3/31/15
CHECK TCIM
REVIEW DL
1/15 P 1526711
PARTICLE SIZE DISTRIBUTION
ASTNI D421, 13422,04318
PROJECT NAME: Sherwood Elementary
SAMPLE ID: GTP-04 S-4 Depth: 7.5 ft-8.0 ft
TYPE:
M11I
N
Hill
I
Mill
ON
Mil
I
MIDI
I
I
I
INS
IN
I
I
I
I
I
0
11111111111
11
11
Ill
H
1
11
Mill
11
li
Hill
III
IINI
COBBLES
E
d)
.0
c-
:5
Z
N
nr
c:
M
F15
SAND
i
Particle Size Particle Size
h-1 P-in', Percern-e
12.0"
304.8
100.0
Cobbles
0.0
6,0"
1542
100.0
3.0"
75
100.0
2.5"
63.5
100.0
Coarse CiTaVel 1
0.0
1.011
50
100.0
1.5"
37.5
100.0
1,011
25
100.0
0.75"
19
100.0
0 375"
9�5
96.5
Fine Gravel
10-1
#4
4.75
89.5
#10
2,00
8Z.5
Coarse $and
6.9
Q0
0.95
75. 2
Medium Sand
21.0
#40
0.43
61,6
#60
0.25
40.7
1
Fine Sand
45.1
0100
0,15
1 24.8
4
1200
1 0.075
16.4
Fine-, 16.4
DGO= 0.41 D30= 0-18 D,,= #N/A
Cu = D60/D 10 #N/A 1111A
Cc= D30^21(010*D60) PN/A _#N/A
I)ESCRIPTIO.N: Silty F-C SAND
soine fine gravel
USCS: Sm I
R
moisture Content
' CH TPM
Tr
DATE 3'311!1
CH ECK rcm
REVIEW DL
3/31/15 PI 526711
PARTICLE SIZE DISTRIBUTION
ASTM 0421, D422, D4318
PROJECT NAME: Sherwood Elementary
SAMPLE 0: GTP-05 S-1 Depth: 1.0 ft-2.0 ft
TYPE:
12" 3* 2" 1. T4' 3/8' #4 010 #40 #60 #10D #200
100
90
80
70
%
P 60
a
S 50
S
40
n
30
20
10
0
1000 100 10 1 0�1 0.01 0.001
Particle size in millimeters
COBBLES
Coarse I Fine
Coj=
Modium I rw
s'llo'cipy
GRAVEL
SAND
FMIES
12.0"
Panicle Size
(run))
304.8
Particle Size
% Passing Classification Percentage
100.0
Moisture Content
E
Z
M
N
. 05
C/)
Cobbles
0.0
6.0"
154.2
100.0
3.01,
75
100.0
2.5"
63.5
100.0
Coarse chavel
0.0
2.0"
50
100.0
1.51,
37.5
100.0
1.0"
25
100.0
0.75"
19
100.0
0.375"
9.5
89.0
Fine Gravel
16.1
#4
1 4.75
83.9
#10
2�00
77.4
Coarse Sand
6.5
#20
0.85
70.6
Medium Sand
1 21.8
#40
0.43
55,5
#60
0.25
32.7
Fine Sand
44.3
#100
OE:57
18.0
0.075 1
11.2
rines 11.2
F D,= 0.52 D30= 0.23 D,,= #N/A
Cu - D60fD10 #NIA #N,,A
Cc = D30�211(1310-D60) IINIA #N,:A
DESCRIPTION: Gravelly F-C SAND
some silt
USCS; SP-Sm
TECH TPM
DATE 31-11/15
CHECK TCM,
REVIEW DL
V31/15 P1 526711
PARTICLE SIZE DISTRIBUTION
ASTM D421, 0422, D4318
PROJECT NAME: Sherwood Elementary
SAMPLE ID: GTP-05 S-2 Depth: 3.0 ft-3.5 ft
TYPE:
0 1111111 11
oil 111
11
ll11111 1 11
mill
IN
11
I
111
1
loll
Ll
43
.0
E
D
Z
U
L
W
Fi- coarse
VEL SAND
I'micle Size Parliclesize
I- P-i- p-l",
12.0"
304.8
100.0
Cobbles
0.0
6.0"
154.2
10010
3.01,
75
100.0
2.5"
.63.5
100.0
Coalse Gravel
0.0
2.0"
50
100.0
1.51,
37.5
100.0
1,01,
- 25
100.0
0.75"
19
100.0
0,375"
9.5
87.8
FincOravel
19.0
#4
4.75
8J.0
110
2.00
75.7
Coarse Sand
5.3
#20
0.85
"
7 - 0
Medium Sand
213
940
0.43
5 4.4
ft60
0.25
30.5
Fine Sand
44.3
IF100
1 0.15
16.2
1 #200
10.075
10.1
Fines 10.1
060= 0.55-� D30= 0.25 D,a= #N/A
IC1,-D60fDI0- #NIA #N/A
Cc = D3()"1,'(DI0*D60) NNIA #N,A
DESCRIPTION: Gravelly F-C SAND
Some silt
USCS: SI'-Sm
Silt or cl
FINES
Moisture Content
TECH
DATE
CHECE
REVIEW
1 33 1115
I
I
I
I
LI
I
11
Appendix H
MGSFIood Reports: Rain Gardens
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
Appendix H
I
MGS FLOOD
PROJECT REPORT
Program Version: MGSFIood 4.34
Program License Number: 200410007
Run Date: 05/07/2015 4:48 PM
Input File Name: Rain Garden 1 - Water Quality.f1d
Project Name: ESD Sherwood
Analysis Title: Rain Garden - Small Site
Comments: Water Quality (1 5-min Timestep): This model demonstrates water quality
compliance of the rain garden, assuming 1.5 ft of bioretention soil infiltrating at a rate of 1.5 in/hr after
reduction factors.
PRECIPITATION INPUT
Computational Time Step (Minutes): 15
Extended Precipitation Timeseries Selected
Climatic Region Number: 2
Full Period of Record Available used for Routing
Precipitation Station 95003605 Puget West 36 in-5min 10/01/1939-10/01/2097
Evaporation Station 951036 Puget West 36 in MAP
Evaporation Scale Factor 0.750
HSPF Parameter Region Number: 1
HSPF Parameter Region Name : USGS Default
Default HSPF Parameters Used (Not Modified by User)
WATERSHED DEFINITION
---------------------- SCENARIO: PREDEVELOPED
Number of Subbasins: 1
---------- Subbasin : Landscape ----------
------- Area(Acres) ----
Till Forest
0.000
Till Pasture
0.000
Till Grass
0.000
Outwash Forest
0.000
Outwash Pasture
0.000
Outwash Grass
0.340
W etland
0.000
Green Roof
0.000
User 2
0.000
Impervious
0.000
----------------------------------------------
Subbasin Total 0.340
---------------------- SCENARIO: POSTDEVELOPED
Number of Subbasins: 1
---------- Subbasin: Pavement ----------
------- Area(Acres)
Till Forest
0.000
Till Pasture
0.000
Till Grass
0.000
Outwash Forest
0.000
Outwash Pasture
0.000
Outwash Grass
0.000
Wetland
0.000
Green Roof
0.000
User 2
0.000
Impervious
0.340
Subbasin Total 0.340
LINK DATA
---------------------- SCENARIO: PREDEVELOPED
Number of Links: 0
LINK DATA
---------------------- SCENARIO: POSTDEVELOPED
Number of Links: 2
------------------------------------------
Link Name: Rain Garden
Link Type: Bioretention Facility
Downstream Link Name: Infiltration Trench
Base Elevation (ft)
100.00
Riser Crest Elevation (ft)
100.50
Storage Depth (ft)
0.50
Bottom Length (ft)
28.7
Bottom Width (ft)
17.4
Side Slopes (ft/ft) L1= 3.00 L2=3.00 W1=3.00 W2=3.00
Bottom Area (sq-ft)
499.
Area at Riser Crest El (sq-ft)
647.
(acres)
0.015
Volume at Riser Crest (cu-ft)
585.
(ac-ft)
0.013
Infiltration on Bottom and Sideslopes Selected
Soil Properties
Biosoil Thickness (ft)
1.50
Biosoil Saturated Hydraulic Conductivity (in/hr)
1.50
Biosoil Porosity (Percent)
40.00
Maximum Elevation of Bioretention Soil : 100.50
Native Soil Hydraulic Conductivity (in/hr)
0.00
Underdrain Present
Orifice NOT Present in Under Drain
Riser Geometry
Riser Structure Type Rectangular
Riser Length (ft) 2.16
Riser Width (ft) :1.83
Common Length (ft) 3.330
Riser Crest Elevation 100.50 ft
Hydraulic Structure Geometry
Number of Devices: 0
Link Name: Infiltration Trench
Link Type: Infiltration Trench
Downstream Link: None
Trench Type
Trench Length (ft)
Trench Width (ft)
Trench Depth (ft)
Trench Bottom Elev (ft)
Trench Rockfill Porosity (%)
Constant Infiltration Option Used
Infiltration Rate (in/hr): 1.00
Trench at Toe of Embankment
36.00
26.30
2.50
96.00
40.00
**********************FLOOD FREQUENCY AND DURATION STATISTICS*******************
---------------------- SCENARIO: PREDEVELOPED
Number of Subbasins: 1
Number of Links: 0
------------------- -- SCENARIO: POSTDEVELOPED
Number of Subbasins: 1
Number of Links: 2
***********Groundwater Recharge Summary
Recharge is computed as input to Perind Groundwater Plus Infiltration in Structures
Total Predeveloped Recharge During Simulation
Model Element Recharge Amount (ac-ft)
Subbasin: Landscape 97.974
Total: 97.974
Total Post Developed Recharge During Simulation
Model Element Recharge Amount (ac-ft)
-----------------------------------------------------------------------------------------------
Subbasin: Pavement 0.000
Link: Rain Garden 0.000
Link: Infiltration Trench Not Computed
Total: 0.000
Total Predevelopment Recharge is Greater than Post Developed
Average Recharge Per Year, (Number of Years= 158)
Predeveloped: 0.620 ac-ft/year, Post Developed: 0.000 ac-ft/year
***********Water Quality Facility Data
----- — - — ----------- SCENARIO: PREDEVELOPED
Number of Links: 0
---------------------- SCENARIO: POSTDEVELOPED
Number of Links: 2
Link: Rain Garden
Infiltration/Filtration Statistics --------------------
Total Runoff Volume (ac-ft): 137.97
Total Runoff Infiltrated (ac-ft): 0.00, 0.00%
Total Runoff Filtered (ac-ft): 129.44, 93.82%
***********Compliiance Point Results
Scenario Predeveloped Compliance Subbasin: Landscape
Scenario Postcleveloped Compliance Link: Rain Garden
Point of Compliance Flow Frequency Data
Recurrence Interval Computed Using Gringorten Plotting Position
Predevelopment Runoff Postclevelopment Runoff
Tr (Years) Discharge (cfs) Tr (Years) Discharge (cfs)
----------------------------------------------------------------------------------------------------
2-Year 3.249E-04 2-Year 0.111
5-Year 3.139E-03 5-Year 0.150
1 0-Year 1.041 E-02 1 0-Year 0.172
25-Year 2.261 E-02 25-Year 0.194
50-Year 3.396E-02 50-Year 0.230
1 00-Year 5.261 E-02 1 00-Year 0.299
200-Year 6.020E-02 200-Year 0.323
RAIN GARDEN 1
EXCEEDS THE
REQUIREMENT OF
91 % TOTAL 24-HOUR
RUNOFFVOLUME
TREATED OF PGIS
SURFACES
I
I.. Record too Short to Comp'ute Peak Discharge for These Recurrence Intervals
I
I
I
I
I
I
MGS FLOOD
PROJECT REPORT
Program Version: MGSFIood 4.34
Program License Number: 200410007
Run Date: 05/07/2015 4:57 PM
Input File Name: Rain Garden 2 - Water Quality.fld
Project Name: ESD Sherwood
Analysis Title: Rain Garden - Small Site
Comments: Water Quality (1 5-min Timestep): This model shows compliance of rain garden
with water quality requirements. This assumes 1.5 ft of bioretention soil draining at 1.5 in/hr after
reduction factors.
PRECIPITATION INPUT
Computational Time Step (Minutes): 15
Extended Precipitation Timeseries Selected
Climatic Region Number: 2
Full Period of Record Available used for Routing
Precipitation Station 95003605 Puget West 36 in-5min 10/01 A 939-10/01/2097
Evaporation Station 951036 Puget West 36 in MAP
Evaporation Scale Factor 0.750
HSPF Parameter Region Number: 1
HSPF Parameter Region Name USGS Default
Default HSPF Parameters Used (Not Modified by User)
WATERSHED DEFINITION
---------------------- SCENARIO: PREDEVELOPED
Number of Subbasins: 1
---------- Subbasin : Landscape ------
------- Area(Acres)
Till Forest
0.000
Till Pasture
0.000
Till Grass
0.000
Outwash Forest
0.000
Outwash Pasture
0.000
Outwash Grass
0.330
Wetland
0.000
Green Roof
0.000
User2
0.000
Impervious
0.000
I
-----------------------------------------------
Subbasin Total 0.330
------- --------- ---- SCENARIO: POSTIDEVELOPED
Number of Subbasins: 1
---------- Subbasin: Pavement ----------
------- Area(Acres) --------
Till Forest
0.000
Till Pasture
0.000
Till Grass
0.000
Outwash Forest
0.000
Outwash Pasture
0.000
Outwash Grass
0.000
Wetland
0.000
Green Roof
0.000
User 2
0.000
Impervious
0.330
Subbasin Total 0.330
LINK DATA
---------------------- SCENARIO: PREDEVELOPED
Number of Links: 0
LINK DATA
---------------------- SCENARIO: POSTDEVELOPED
Number of Links: 2
Link Name: Rain Garden
Link Type: Bioretention Facility
Downstream Link Name: Infiltration Trench
Base Elevation (ft)
100.00
Riser Crest Elevation (ft)
100.50
Storage Depth (ft)
0.50
Bottom Length (ft)
25.0
Bottom Width (ft)
20.0
Side Slopes (ft/ft) Ll= 3.00 L2=3.00 W1=3.00 W2=3.00
Bottom Area (sq-ft)
500.
Area at Riser Crest El (sq-ft)
644.
(acres)
0.015
Volume at Riser Crest (cu-ft)
585.
(ac-ft)
0.013
Infiltration on Bottom and Sideslopes Selected
Soil Properties
17,
Biosoil Thickness (ft) 1.50
Biosoil Saturated Hydraulic Conductivity (in/hr) 1.50
Biosoil Porosity (Percent) 40.00
Maximum Elevation of Bioretention Soil : 100.50
Native Soil Hydraulic Conductivity (in/hr) 0.00
Underdrain Present
Orifice NOT Present in Under Drain
Riser Geometry
Riser Structure Type Rectangular
Riser Length (ft) 2.17
Riser Width (ft) 1.83
Common Length (ft) 3.330
Riser Crest Elevation 100.50 ft
Hydraulic Structure Geometry
Number of Devices: 0
------------------------------------------
Link Name: Infiltration Trench
Link Type: Infiltration Trench
Downstream Link: None
Trench Type
Trench at Toe of Embankment
Trench Length (ft)
31.00
Trench Width (ft)
27.00
Trench Depth (ft)
2.50
Trench Bottom Elev (ft)
96.00
Trench Rockfill Porosity
40.00
Constant Infiltration Option Used
Infiltration Rate (in/hr): 1.00
**********************FLOOD FREQUENCY AND DURATION STATISTICS*******************
---------------------- SCENARIO: PREDEVELOPED
Number of Subbasins: 1
Number of Links: 0
---------------------- SCENARIO: POSTI)EVELOPED
Number of Subbasins: 1
Number of Links: 2
"'"Groundwater Recharge Summary
Recharge is computed as input to Perind Groundwater Plus Infiltration in Structures
Total Predeveloped Recharge During Simulation
Model Element Recharge Amount (ac-ft)
Subbasin: Landscape 95.093
I
Total: 95.093
Total Post Developed Recharge During Simulation
Model Element Recharge Amount (ac-ft)
------------------------------------------------------- 7 ---------------------------------------
Subbasin: Pavement 0.000
Link: Rain Garden 0.000
Link: Infiltration Trench Not Computed,
Total: 0.000
Total Predevelopment Recharge is Greater than Post Developed
Average Recharge Per Year, (Number of Years= 158)
Predeveloped: 0.602 ac-ft/year, Post Developed: 0.000 ac-ft/year
Water Quality Facility Data
---- -- SCENARIO: PREDEVELOPED
Number of Links: 0
--------- - ----------- SCENARIO: POSTI)EVELOPED
Number of Links: 2
Link: Rain Garden
Infiltration/Filtration Statistics --------------------
Total Runoff Volume (ac-ft): 133.96
Total Runoff Infiltrated (ac-ft): 0.00, 0.00%
Total Runoff Filtered (ac-ft): 126.14, 94.16%
P&r—cenf Tfe—ate—d-(Iiifiltr—afe-d:�Filter—edY/T6t-al-V615-m—e.
***********Compl1iance Point Results
Scenario Predeveloped Compliance Subbasin: Landscape
Scenario Postcleveloped Compliance Link: Rain Garden
*** Point of Compliance Flow Frequency Data ***
Recurrence Interval Computed Using Gringorten Plotting Position
Predevelopment Runoff
Postclevelopment Runoff
Tr (Years) Discharge (cfs)
---------------------------------------------------------------------------------------------------
Tr (Years) Discharge (cfs)
2-Year 3.153E-04
2-Year 0.108
5-Year 3.046E-03
5-Year 0.146
1 0-Year 1.01 OE-02
1 0-Year 0.167
25-Year 2.194E-02
25-Year 0.188
50-Year 3.296E-02
50-Year 0.224
1 00-Year 5.106E-02
1 00-Year 0.285
200-Year 5.843E-02
200-Year 0.312
RAIN GARDEN 2
EXCEEDS THE
REQUIREMENT OF
91 % TOTAL 24-HOU R
RUNOFFVOLUME
TREATED OF PGIS
SURFACES
** Record too Short to Compute Peak Discharge for These Recurrence Intervals
0
Z12
I
Appendix I
MGSFlood Reports: Infiltration Basins
I
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
1 - Appendix I
11
MGS FLOOD
PROJECT REPORT
Program Version: MGSFIood 4.34
Program License Number: 200410007
Run Date: 05/07/2015 4:53 PM
Input File Name: Rain Garden 1 - Flow Control.fld
Project Name: ESD Sherwood
Analysis Title: Rain Garden, - Small Site
Comments: Flow Control (1 -hr Timestep): This model shows Edmonds Specific Flow Control
compliance for a Small Project Site for the infiltration basin below the rain garden. Assumes 1 in/hr
native, i nf i I rate. PRECIPITATION INP . UT
Computational Time Step (Minutes): 60
Extended Precipitation Timeseries Selected
Climatic Region Number: 2
Full Period of Record Available used for Routing
Precipitation Station 95003605 Puget West 36 in-5min 10/01 /1939-10/01/2097
Evaporation Station 951036 Puget West 36 in MAP
Evaporation Scale Factor 0.750
HSPF Parameter Region Number: 1
HSPF Parameter Region Name USGS Default
Default HSPF Parameters Used (Not Modified by User)
WATERSHED DEFINITION-***********************
----------------- — --- SCENARIO: PREDEVELOPED
Number of Subbasins: 1
--------- Subbasin : Landscape ------
-
------- Area(Acres)
Till Forest
0.000
Till Pasture
o.00b
Till Grass
0.000
Outwash Forest
0.000
Outwash Pasture
0.000
Outwash Grass
0.340
Wetland
0.000
Green Roof
0.000
User 2
0.000
Impervious
0.000
----------------------------------------------
Subbasin Total 0.340
------------ -------- SCENARIO: POSTIDEVELOPED
Number of Subbasins: 1
---------- Subbasin: Pavement ----------
------- Area(Acres) --------
Till Forest
0.000
Till Pasture
0.000
Till Grass
0.000
Outwash Forest
0.000
Outwash Pasture
0.000
Outwash Grass
0.000
Wetland
0.000
Green Roof
0.000
User2
0.000
Impervious
0.340
Subbasin Total 0.340
LINK DATA
---------------------- SCENARIO: PREDEVELOPED
Number of Links: 0
LINK DATA
---------------------- SCENARIO: POSTDEVELOPED
Number of Links: 2
..........................................
Link Name: Rain Garden
Link Type: Bioretention Facility
Downstream Link Name --Infiltration Trench
Base Elevation (ft)
100.00
Riser Crest Elevation (ft)
100.50
Storage Depth (ft)
0.50
Bottom Length (ft)
28.7
Bottom Width (ft)
17.4
Side Slopes (ft/ft) Ll = 3.00 L2=3.00 W1=3.00 W2=3.00
Bottom Area (sq-ft)
499.
Area at Riser Crest El (sq-ft)
647.
(acres)
0.015
Volume at Riser Crest (cu-ft)
585.
(ac-ft)
0.013
Infiltration on Bottom and,8ideslopes Selected
Soil Properties
I
Biosoil Thickness (ft)
1.50
Biosoil Saturated Hydraulic Conductivity (in/hr)
1.50
Biosoil Porosity (Percent)
40.00
Maximum Elevation of Bioretention Soil : 100.50
Native Soil Hydraulic Conductivity (in/hr)
0.00
Underdrain Present
Orifice NOT Present in Under Drain
Riser Geometry
Riser Structure Type Rectangular
Riser Length (ft) 2.16
Riser Width (ft) 1.83
Common Length (ft) 3.330
Riser Crest Elevation 100.50 ft
Hydraulic Structure Geometry
Number of Devices: 0
Link Name: Infiltration Trench
LinkType: Infiltration Trench
Downstream Link: None
Trench Type
Trench at Toe of Embankment
Trench Length (ft)
36.00
Trench Width (ft)
26.30
Trench Depth (ft)
2.50
Trench Bottom Elev (ft)
Trench Rockfill Porosity
96.00
40.00
Constant Infiltration Option Used
Infiltration Rate (in/hr): 1.00
**********************FLOOD FREQUENCY AND DURATION STATISTICS*******************
---------------------- SCENARIO: PREDEVELOPED
Number of Subbasins: 1
Number of Links: 0
---------------------- SCENARIO: POSTDEVELO'PED
Number of Subbasins: 1
Number of Links: 2
*—*--Groundwater Recharge Summary
Recharge is computed as input to PerInd Groundwater Plus Infiltration in Structures
Total Predeveloped Recharge During Simulation
Model Element Recharge Amount (ac-ft)
-----------------------------------------------------------------------------------------------
Subbasin: Landscape 98.181
I
Total:
98.181
Total Post Developed Recharge During Simulation
Model Element . Recharge Amount (ac-ft)
----------------------------------------------------------------------------------
Subbasin: Pavement 0.000
Link: Rain Garden Not Computed
Link: Infiltration Trench 136.166
Total:
136.166
Total Predevelopment Recharge is Less than Post Developed
Average Recharge Per Year, (Number of Years= 158)
Predeveloped: 0.621 ac-ft/year, Post Developed: 0.862 ac-ftlyear
***********Water Quality Facility Data
---------------------- SCENARIO: PREDEVELOPED
Number of Links: 0
------------------ — -- SCENARIO: POSTDEVELOPED
Number of Links: 2
Link: Infiltration Trench
Infiltration/Filtration Statistics --------------------
Total Runoff Volume (ac-ft): 137.32
Total Runoff Infiltrated (ac-ft): 136.17, 99.16%
Total Runoff Filtered (ac-ft): 0.00, 0.00%
Percent Treated (Infiltrated+Filtered)/Total Volume: 99.16%
***********Compliance Point Results
Scenario Predeveloped Compliance Subbasin: Landscape
Scenario Postcleveloped Compliance Link: Infiltration Trench
*** Point of Compliance Flow Frequency Data ***
Recurrence Interval Computed Using Gringorten Plotting Position
Predevelopment Runoff
Tr (Years) Discharge (cfs)
-------------------------------------------
2-Year
4.523E-04
5-Year
2.944E-03
1 0-Year
1.036E-02
25-Year
1.697E-02
50-Year
2.545E-02
1 00-Year
5.206E-02
200-Year
5.864E-02
Postclevelopment Runoff
Tr (Years) Discharge (cfs)
-------------------------------------------------------------------
(2:Ye—a�r�
(8-.5-1-6E--06
5-Year
4.61 OE-02
(1-0--y
25-Year
(7:745E--02
0.104
FLOWS DO NOT
50-Year
0.116
EXCEED THE
(1 00--Ye—a-r::=
F-071 21
EDMONDS-SPECIFIC
200-Year
FLOW CONTROL
REQUIREMENTS
I
I". Record too Short to Compute Peak Discharge for These Recurrence Intervals
I
I
I
I
� I
� I
I
I
� I
� I
MGS FLOOD
PROJECT REPORT
Program Version: MGSFIood 4.34
Program License Number: 200410007
Run Date: 05/07/2015 4:59 PM
Input File Name: Rain Garden 2 - Flow Control.fld
Project Name: ESD Sherwood
Analysis Title: Rain Garden - Small Site
Comments: Flow Control (1 -h r Timestep): This model shows Edmonds Specific Flow Control
compliance for a Small Project Site for the infiltration basin below the rain garden. Assumes 1 in/hr
native infil rate.
PRECIPITATION INPUT
Computational Time Step (Minutes): 60
Extended Precipitation Timeseries Selected
Climatic Region Number: 2
Full Period of Record Available used for Routing
Precipitation Station 95003605 Puget West 36 in-5min 10/01 /1939-10/01/2097
Evaporation Station 951036 Puget West 36 in MAP
Evaporation Scale Factor 0.750
HSPF Parameter Region Number: 1
HSPF Parameter Region Name : USGS Default
Default HSPF Parameters Used (Not Modified by User)
WATERSHED DEFINITION
---------------------- SCENARIO: PREDEVELOPED
Number of Subbasins: 1
---------- Subbasin : Landscape ----------
------- Area(Acres) --------
Till Forest
0.000
Till Pasture
0.000
Till Grass
0.000
Outwash Forest
0.000
Outwash Pasture
0.000
Outwash Grass
0.330
Wetland
0.000
Green Roof
0.000
User 2
0.000
Impervious
0.000
----------------------------------------------
Subbasin Total 0.330
----- ---..--..—..SCENARIO: POSTI)EVELOPED
Number of Subbasins: 1
---------- Subbasin: Pavement -------
------- Area(Acres)
Till Forest
0.000
Till Pasture
0.000
Till Grass
0.000
Outwash Forest
0.000
Outwash Pasture
0.000
Outwash Grass
0.000
Wetland
0.000
Green Roof
0.000
User 2
0.000
Impervious
0.330
Subbasin Total 0.330
LINK DATA
---------------------- SCENARIO: PREDEVELOPED
Number of Links: 0
LINK DATA
---------------------- SCENARIO: POSTDEVELOPED
Number of Links: 2
----------------------------------------
Link Name: Rain Garden
Link Type: Bioretention Facility
Downstream Link Name: Infiltration Trench
Base Elevation (ft)
100.00
Riser Crest Elevation (ft)
100.50
Storage Depth (ft)
0.50
Bottom Length (ft)
25.0
Bottom Width (ft)
20.0
Side Slopes (ft/ft) Ll = 3.00 L2=3.00 Wl=-3.00 W2=3.00
Bottom Area (sq-ft)
500.
Area at Riser Crest El (sq-ft)
644.
(acres)
0.015
Volume at Riser Crest (cu-ft)
585.
(ac-ft)
0.013
Infiltration on Bottom and Sideslopes Selected
Soil Properties
Biosoil Thickness (ft) 1.50
Biosoil Saturated Hydraulic Conductivity (in/hr) 1.50
Biosoil Porosity (Percent) 40.00
Maximum Elevation of Bioretention Soil : 100.50
Native Soil Hydraulic Conductivity (in/hr) 0.00
Underdrain Present
Orifice NOT Present in Under Drain
Riser Geometry
Riser Structure Type Rectangular
Riser Length (ft) 2.17
Riser Width (ft) 1.83
Common Length (ft) 3.330
Riser Crest Elevation 100.50 ft
Hydraulic Structure Geometry
Number of Devices: 0
Link Name: Infiltration Trench
Link Type: Infiltration Trench
Downstream Link: None
Trench Type
Trench at Toe of Embankment
Trench Length (ft)
31.00
Trench Width (ft)
27.00
Trench Depth (ft)
2.50
Trench Bottom Elev (ft)
96.00
Trench Rockfill Porosity
40.00
Constant Infiltration Option Used
Infiltration Rate (in/hr): 1.00
**********************FLOOD FREQUENCY AND DURATION STATISTICS*******************
---------------------- SCENARIO: PREDEVELOPED
Number of Subbasins: 1
Number of Links: 0
---------------------- SCENARIO: POSTI)EVELOPED
Number of Subbasins: 1
Number of Links: 2
""'Groundwater Recharge Summary
Recharge is computed as input to PerInd Groundwater Plus Infiltration in Structures
Total Predeveloped Recharge During Simulation
Model Element Recharge Amount (ac-ft)
-----------------------------------------------------------------------------------------------
Subbasin: Landscape 95.294
I
I
Total:
95.294
Total Post Developed Recharge During Simulation
Model Element Recharge Amount (ac-ft)
--------------------------------------------------------------------------------------
Subbasin: Pavement 0.000
Link: Rain Garden Not Computed
Link: Infiltration Trench 131.736
Total:
131.736
Total Predevelopment Recharge is Less than Post Developed
Average Recharge Per Year, (Number of Years= 158)
Predeveloped: 0.603 ac-ft/year, Post Developed: 0.834 ac-ftlyear
***********Water Quality Facility Data
----- — --------- ---- SCENARIO: PREDEVELOPED
Number of Links: 0
------ - - - ----------- SCENARIO: POSTDEVELOPED
Number of Links: 2
Link: Infiltration Trench
Infiltration/Filtration Statistics --------------------
Total Runoff Volume (ac-ft): 133.42
Total Runoff Infiltrated (ac-ft): 131.74, 98.74%
Total Runoff Filtered (ac-ft): 0.00, 0.00%
Percent Treated (Infiltrated+Filtered)/Total Volume: 98.74%
***********Compliance Point Results
Scenario Predeveloped Compliance Subbasin: Landscape
Scenario PostdeVeloped Compliance Link: Infiltration Trench
*** Point of Compliance Flow Frequency Data ***
Recurrence Interval Computed Using Gringorten Plotting Position
Predevelopment Runoff
Postdevelopment Runoff
Tr (Years)
----------------------------------------------------------------------------------------------------------------------
Discharge (cfs)
Tr (Years) Discharge (cfs)
2-Year
4.390E-04
(2--y
(9-.503E--06
5-Year
2.858E-03
5-Year
6.501 E-02
1 0-Year
1.006E-02
-G-Y:
(1 e:a:r=:=
- -1-5E-0
(8.2 -
N\\\\EDMONDS-SPECIFIC
25-Year
1.647E-02
25-Year
0.106
50-Year
2.470E-02
50-Year
0.117
F
FLOWS DO NOT
1 00-Year
5.053E-02
(1-00:Y
F—O-.1'21
E
EXCEED THE
200-Year
5.691 E-02
200-Year
0.126
FLOW CONTROL
REQUIREMENTS
** Record too Short to Compute Peak Discharge for These Recurrence Intervals
� I
L
17
L
Appendix J
MGSFlood Model Snapshots
� I
I
� I
I
E
I
� I
I
F,
11
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
1 . Appendix J
ESD SHERWOOD ELEMENTARY - DRAINAGE REPORT
TRAFFIC AND PEDESTRIAN SAFETY APPENDIX J
IMPROVEMENTS
MGS FLOOD - RAIN GARDEN MODELING
I r ]L
Copy ; Print...
image I i
-Objects
PAVEMENT CELL LINKED TO....... GARDEN
S ubbasin CELL. THIS ACCOUNTS FOR ALL FLOWS
M)O- copy BEING DIRECTED TO THE RAIN GARDEN
CELL FOR TREATMENT.
S tructure III
Open Channel POINT OF COMPLIANCE SET
AT RAIN GARDEN CELL FOR
Infilt Trench WATER QUALITY MODELING
User Rating R ain Garden
S plitter
CAVFS
Filter Strip
Bioretention
Infiltration Trend
Porous
W Pavement RAIN GARDEN CELL LINKED TO
INFILTRATION CELL. THIS ACCOUNTS FOR
L FLOWS (BOTH TREATED AND
UNTREATED) MOVING FROM THE RAIN
GARDEN CELL TO THE INFILTRATION CELL
Figure 1 — Model Layout
1] L
I
I
I
Geometry Outlet Structure(s)/Underdrain
Structure Name
Max Elevation Prec,ip[Evap
of Bi&�Sbil Sfi6ws"risw outlet structure"
jaftimative': "verticial o'fifice'and over4lown)
Opp
MEMEW MEMEME EMEMEM
INNE
.. .......
. . . .. .. . . . . .
Underdrain with Opbonal Office
U)
Bioretention . �z C:
(tf Underdrain is not indbidecL t�en
soil Floor .0
El . evation* infiltrated ffmistuie is lost fmm systern)
-Geomet
zi Z2
Z3 Z4
Side Slopes [ZHAV) 3-oo oo
F-- J, F--j--]
3.00
F--__j
I
Bottom Length, L (it) F____28.7J0
Bottom Width, W [it)
Maximum Elevation of Bioietention Soil (it)
Biotetention Floor Elevation (it)
BioFetention Soil Thickness (ft)
F --- -1 -5-61
Bioietention Soil Porosity (2)
40.00
Bioietention Soil Infiltration Rate (in/hi)
1___1.5001
j
Native Soil Infiltration Rate (in/hF)
0.000
ry infiltration on Bottom and Sideslopes
0 Infiltration on Bottom Only
0—k Cancel
Figure 2 — Rain Garden Geometry
IN
NATIVE SOIL
INFILTRATION RATE
IS SET AT 0 IN/HR
TO ENSURE THAT
ALL TR EATED
FLOWS ARE
ACCOUNTED FOR
IN THE LINK THAT
DIRECTS FLOWS
FROM THE RAIN
GARDEN CELL TO
THE INFILTRATION
CELL.
G eometry
Outlet Structute(s)/Underdiain
E nable Structure Type Control El. [ft) Diameter (in) Orientation
L_j rov Horizontal
(7) Vertical
E nable Structure Type Control El. (ft) Diameter (in) Orientation
r 7 FT —1—mulai Orifice rt-1 Horizontal
r) Vertical
Optional Overflow Structure
Structure Type Crest El. (ft) Length (ft) Width (ft) Common L (ft) Riser Top Open
aflow Riser 100.50IF-1 6 F-1.831 G) Y e s
k. — . 0 No
-UndeidFain Data
—OVERFLOW RISER WITH TYPE 1 CB
P-0i Include UndeFdFain DIMENSIONS INCLUDED IN THE
MODEL. ALL UNTREATED FLOWS (IN
Include Orifice in UndeFdFain
EXCESS OF RAIN GARDEN
U deFdFain Orifice Control Elevation (It) CAPACITY) ARE MODELED AS
U deFdjain Orifice Diameter (inches) MOVING FROM THE RAIN GARDEN
CELL TO THE DOWNSTREAM
Note: If underdrain is not included, then water infiltrates at th, INFILTRATION CELL THROUGH THE
native soil saturated hydraulic conductivity. LINK IN FIGURE 1.
UNDERDRAIN INCLUDED IN THE
MODEL. WITH A NATIVE SOIL
INFILTRATION RATE OF 0 IN/HR FOR
THE RAIN GARDEN CELL, ALL
TREATED FLOWS FROM THE RAIN
GARDEN CELL ARE DIRECTED TO THE
DOWNSTREAM INFILTRATION CELL
THROUGH THE LINK IN FIGURE 1.
I
Figure 3 — Rain Garden Outlet Structure and Underdrain
--a
234-MM-ter QT371 020.at MRM MGTF, �U!1111111111111
e' * r- - u- a- * iii D, - a- ' i * a*":: Flow Splitter Calculator
.................................. . ................
Compute Water Quality Treatment Volume for Link
Computed Basic Wet Pond Volume, 91 % E xceedance (cu-ft):
Computed Large Wet Pond Volume (Phosphorous Control), 1. 5'B asic Volume (cu-ft): Mot Computed
Time to Infiltrate 91 % Treatment Volume, (Applies to Infiltration Facilities) Not Computed]
Compute Infiltration/Filtration Statistics
Total Runoff Volume 137.97 ac-fl Percent Treated
(Infiltrated+Filtered)/Tota
Total Runoff Infiltrated 0.00 ac-ft,0.00*q
Total Runoff Filtered 129.44 ac-ft 93.82
Lj Compute 2-yr Discharge Rate for Link Outflow (cis) Not omputed
qCOMPUTED WATER QUALITY ge for /Uilnflow
OnTREATMENT STATISTICS OF THE RAIN
offGARDEN CELL (RAIN GARDEN 1
MODEL USED IN THIS FIGURE)
C Lose j
Figure 4 — Rain Garden Water Quality Data
ESD SHERWOOD ELEMENTARY -
TRAFFIC AND PEDESTRIAN SAFETY
IMPROVEMENTS
DRAINAGE REPORT
APPENDIX J
MGS FLOOD - INFILTRATION BASIN MODELING
7,
Objects
* Subbasin
-0. Copy
Structure
Open Channel
Pavement
Infilt Trench
User Rating
Splitter
CAVFS
Filter Strip
Biotetention
Porous
= Pavement
RAIN GARDEN CELL LINKED TO
INFILTRATION CELL. THIS ACCOUNTS FOR
ALL FLOWS (BOTH TREATED AND
UNTREATED) MOVING FROM THE RAIN
GARDEN CELL TO THE INFILTRATION CELL
Copy 11 Print...
Image
PAVEMENT CELL LINKED TO RAIN GARDEN
CELL. THIS ACCOUNTS FOR ALL FLOWS
BEING DIRECTED TO THE RAIN GARDEN
CELL FOR TREATMENT.
POINT OF COMPLIANCE SET
AT INFILTRATION CELL FOR
7—WATER QUALITY MODELING
Figure 1 — Model Layout
Infiltration 'trench Definition (Post): Infiltration Trench
Trench Geometry I Optimization Data
Standard Infiltration I rench Structure Name
(View Looking Dcwnstream) I Infiltration Trench
Road
Z
Trench liGravel Filled
Depth -2
lIc- > Trench
Depth to Width
Water Table
r Trench Located on Embankment Sides[Qpe
ro Trench Located Beneath Ditch
r- Trench Geometry
Trench Sideslope Left (ZHAV) 0.20
T rench S ideslope R ight (ZH: 1 V) 0.20
Ditch Bedslope (ft/ft) F 0 000
Ditch Mannings n Roughness 0.024
------------
Trench Bottom Elev at Downstream End (ft) 96.00
Trench Length (ft) 36.0
Trench Depth [ft) 2.50
Trench Width (ft) 26.30
Rock Fill Porosity % Noll Voids/T ot Vol) 40T
Infiltration Optiion--------,
r Massmann Infiltration r- Constant Infiltration
11 1 OIL UF1 FIPUt
Hydraulic Conductivity (in/hr) G.C10
D epth to Water T able B eneath T rench (ft) 1 Oil, C1
170
F,
Effective Infiltration Rate at 0 Depth (in/hr) 5.400
Constant I nfiltFation Input
Constant Infiltration Rate (in/hr) — — —
1 00
Ok
Figure 2 — Infiltration Basin Geometry
Q
M
La
ii
L:3
Appendix K
Conveyance Calculations
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
Appendix K
Site Conveyance Calculation ESID Sherwood
4/17/2015
Calculation By: Alex Sundell
k-PC
25 YR FLOW DESIGN
Location Discharge
Pipe Design
IP ipe .1-10W
Pipe
g
Engineers Pervious Impervious Drainage Add'I Total Flow
Diameter Velocity
Capacity
Pipe Manning's
Drainage Basin Area (ac) Area (ac) Area (A) Ci CP I (in/hr) Runoff cfs inflow cfs cfs
It Pipe Slope ft/s
cfs Check
Length ft Mat'i Type
Proposed Basin A 0.180 0.310 0.490 0.900 0.250 3.800 1.231 0 1.231
0.67 .0.5% 3.5S
1.25 OK
24 HDPE 0.0090
Proposed Basin D 1 0.050 0.340 0.390 0.900 0.250 3.800 1.210 0 1.210
0.671 0.5% 3.55
1.25 CK
27
Velocity Calculated as (1.486/n)x[(D/4 )213]XV(S)
Pipe Capacity is calculated as: VnD 2 A
Runoff flows calculated with the Rational Method per WSDOT Hydraulics Manual
Tc-1=5 minutes (i=3.8 in/hr) Calculated per WSDOT Hydraulics Manual
Interpolated 100-yr m and n values from Figure 2-5.4A between Everett and Seattle
m 9.46
n 0.5657
Reference: SWMMWW, WSDOT Hydraulics Manual
I
Appendix L
Rain Garden and Infiltration Basin Maintenance Standards
I
I
I
11
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
1 Appendix L
For more detailed information on maintenance, see Volume V, Section 4.6
— Maintenance Standards for Drainage Facilities.
Verification of Performance
During the first 1-2 years of operation verification testing (specified in
SSC-9) is strongly recommended, along with a maintenance program that
results in achieving expected performance levels. Operating and
maintaining ground water monitoring wells (specified in Section 3.3.7 -
Site Suitability Criteria) is also strongly encouraged.
3.3.10 Infiltration Basins
This section covers design and maintenance criteria specific for infiltration
basins. (See schematic in Figure 3.25)
Description:
infiltration basins are earthen impoundments used for the collection,
temporary storage and infiltration of incoming stormwater runoff.
Design Criteria Speciftcfor Basins
Access should be provided for vehicles to easily maintain the forebay
(presettling basin) area and not disturb vegetation, or resuspend
sediment any more than is absolutely necessary.
The slope of the basin bottom should not exceed 3% in any direction.
A minimum of one foot of freeboard is recommended when
establishing the design ponded water depth. Freeboard is measured
from the rim of the infiltration facility to the maximum ponding level
or from the rim down to the overflow point if overflow or a spillway is
included.
Treatment infiltration basins must have sufficient vegetation
established on the basin floor and side slopes to prevent erosion and
sloughing and to provide additional pollutant removal. Erosion
protection of inflow points to the basin must also be provided (e.g.,
riprap, flow spreaders, energy dissipators (See Chapter 4)). Select
suitable vegetative materials for the basin floor and side slopes to be
stabilized. Refer to Chapter 0 for recommended vegetation.
Lining material — Basins can be open or covered with a 6 to 12-inch
layer of filter material such as coarse sand, or a suitable filter fabric to
help prevent the buildup of impervious deposits on the soil surface. A
nonwoven geotextile should be selected that will function sufficiently
without plugging (see geotextile specifications in Appendix V-C of
Volume V). The filter layer can be replaced or cleaned when/if it
becomes clogged.
February 2005 Volume I// — Hydrologic Analysis and Flow Control BMPs 3-97
I
Vegetation — The embankment, emergency spillways, spoil and
borrow areas, and other disturbed areas should be stabilized and
planted, preferably with grass, in accordance with Stormwater Site
Plan (See Minimum Requirement #1 of Volume 1). Without healthy
vegetation the surface soil pores would quickly plug.
Maintenance Criteria for Basins
Maintain basin floor and side slopes to promote dense turf with
extensive root growth. This enhances infiltration, prevents erosion and
consequent sedimentation of the basin floor, and prevents invasive
weed growth. Bare spots are to be immediately stabilized and
revegetated.
Vegetation growth should not be allowed to exceed 18 inches in
height. Mow the slopes periodically and check for clogging, and
erosion.
Seed mixtures should be the same as those recommended in Table 3.2.
The use of slow -growing, stoloniferous grasses will permit long
intervals between mowing. Mowing twice a year is generally
satisfactory. Fertilizers should be applied only as necessary and in
limited amounts to avoid contributing to ground water pollution.
Consult the local extension agency for appropriate fertilizer types,
including slow release fertilizers, and application rates.
3.3.11 Infiltration Trenches
This section covers design, construction, and maintenance criteria specific
for infiltration trenches.
Description:
Infiltration trenches are generally at least 24 inches wide, and are
backfilled with a coarse stone aggregate, allowing for temporary storage
of stormwater runoff in the voids of the aggregate material. Stored runoff
then gradually infiltrates into the surrounding soil. The surface of the
trench can be covered with grating and/or consist of stone, gabion, sand,
or a grassed covered area with a surface inlet. Perforated rigid pipe of at
least 8-inch diameter can also be used to distribute the storinwater in a
stone trench.
See Figures 3.30 for schematic of an infiltration trench. See Figures 3.3 1,
3.32, 3.33, 3.34, and 3.35 for examples of trench designs.
3-98 Volume Hydrologic Analysis and Flow Control BMPs February 2005
Appendix M
Settling Tank Sizing Calculations
Sherwood Elementary Traffic and Pedestrian Safety Improvements— Edmonds School District No. 15
1 Appendix M
ESD Sherwood - 2-Year Stormwater Peak Flow Pre -Construction
(117nfpj"tt,)�111111111111111111111111 I — . I
(numbers calculated by spreadsheet)
SBUH method for calculating runoff for a 10-year, 24 hr, T 1A t rm
Rainfall depth for 24 hr storm 11. flinches Per SWMMWW Appendix 111-A
Tc �.;A, I I III lutus dt= 5 minutes
CN value pervious
pervious area
DEMON*
SiM111111IM'
S= 1.2486
acres 0.2S= 0.2497
CN value for impervious
Impervious area
i4�9
S= 0.2041
acres 0.2S= 0.0408
IOMOMIJ
i otal Area
Peak Flow Rate
Minimum Hydraulic Retention Time
Minimum Sediment Tank Volume Required
Note: Design based upon Technical Memc
u.33 acres 14314.6 ST
0.22 cfs 97.81gpm
90.0 min
8,806 Igallons Peak Flow gpm x 90 min
VVAA t>hGjU,)0:,�,-k Lke((LAa-,+O-,k/V
-7 o
w—
?
7— Ap
U-44c.
Aj
;YJ
oil
IN 177
AA*-Ooar W/
-- MInin
go
f
.Ott
V XW SOO e im.
Alt
Ar,
Y,vo
t-7
Zo e,
Se acks R
ront1V/VJ . . . . . .
- �Ttt ZZp
ides-5/C -
Rear iAAR 26 202 wxv wpewoJ5 4f3--,,�
Other 15' REET FILE DEVELOPMENT SERVICES
Height —7 ST COUNTER
2— 9� D I D6�N AV-e,
AUG 2 5 2000
DETERMINATION OF NONSIGNIFICANCE PLAM�WG DEPY-
Edmonds School District No. 15
Sherwood Field Improvement Project
DESCRIPTION OF PROPOSAL: The Sherwood Field Improvement project consists of
two phases. Phase 1 to occur this year involves construction of a 5-foot wide asphalt
path around the perimeter of the existing grass playfield, drainage facilities, and
enlarging the existing play equipment area. Phase 2 of the project, to occur in 2001,
involves renovation the grass playfield.
PROPONENT: Edmonds School District No. 15.
LOCATION OF PROPOSAL: Sherwood Elementary School, 22901 106 th Avenue,
West, Edmonds, Washington 98020
LEAD AGENCY: Edmonds School District No. 15.
The lead agency for this proposal has determined that it does not have a probable
significant adverse impact on the environment. An environmental impact statement
(EIS) is not required under RCW 43.21 C.030(2)(c). This decision was made after
review of an environmental checklist and other information on file with the lead agency.
This information is available to the public on request.
This DNS is issued under WAC 197-11-340�2). The lead agency will not act on this
proposal for 14 days from the date below. Comments must be submitted to the
Responsible Official, Edmonds School District, 20420 68th Avenue West, Lynnwood,
Washington 98036-7400 by August 14, 2000.
RESPONSIBLE OFFICIAL: Bret M. Carlstad
POSITION/TITLE: Director Planning and Property Management
PHONE: (425) 670-7334
ADDRESS: Edmonds School District No. 15, 20420 68th Avenue West, Lynnwood,
Washington 98036-7400.
DATE: August 24, 2000
PUBLISHED: August 24, 2000
There is no agency appeal.
SIGNATUR������,,-
1 -4-
EDMONDS SCHOOL DISTRICT
ENVIRONMENTAL CHECKLIST FORM
Applicant: Edmonds School District #15
Attn: Bret M. Carlstad
Planning and Property Management
20420 68th Avenue West
Lynnwood, WA 98036-7400
Project: Sherwood Elementary Field Improvement
4
EDMONDS SCHOOL DISTRICT
Environmental Checklist Form
A. BACKGROUND
1. Name of proposed project, if applicable:
Sherwood Elementary Field Improvement
2. Name of applicant
Edmonds School District No. 15
3. Address and phone number of applicant and contact person:
Owner:
Edmonds School District No. 15
20420 68th Avenue West
Lynnwood, WA 98036-7400
Phone: (206) 670-7334
Bret Carlstad - SEPA Official
4. Date checklist prepared:
July 10, 2000
5. Agency requesting checklist:
Edmonds School District - Lead agency for SEPA review.
6. Proposed timing or Schedule (including phasing, if applicable):
Phase 1 of the project is proposed to begin construction this summer to be completed fall
2000.
7. Do you have any plans for future additions, expansion, or further activity related to
or connected with this proposal? If yes, explain.
Yes, Phase 2 of the project will consist of renovating the existing grass playfield. This
work is planned for next summer (2001).
8. List any environmental information you know about that has been prepared, or will
be prepared, directly related to this proposal.
None
9. Do you know whether applications are pending for governmental approvals of other
proposals directly affecting the property covered by your proposal? If yes, explain.
No
10. List any government approvals or permits that will be needed for your proposal, if
known.
A grading permit is required by the City of Edmonds in order to construct the proposed
project.
11. Give brief, complete description of your proposal, including the proposed uses and
the size of the project and site. There are several questions later in this checklist that
ask you to describe certain aspects of your proposal. You do not need to repeat
those answers on this page.
Phase I of the Sherwood project involves the construction of a 5-foot wide asphalt path
around the perimeter of the existing field; drainage facilities; and enlarging the existing
play equipment area. Phase 2 of the project involves renovating the existing grass
playfield.
12. Location of the proposal. Give sufficient information for a person to understand the
precise location of your proposed project, including a street address, if any, and
section, township, and range, if known. If a proposal would occur over a range of
area, provide the range or boundaries of the site(s). Provide a legal description, site
plan, vicinity map, and topographic map, if reasonably available. While you should
submit any plans required by the agency, you are not required to duplicate maps or
detailed plans submitted with any permit applications related to this checklist.
Sherwood Elementary is located at 22901 106'hAve. West in Edmonds. The existing
field where the proposed project will take place is located at the north end of the property
and is bordered by 106" Ave. to the west and 228t' Street to the north.
See attached legal description and site map.
EDMONDS SCHOOL DISTRICT NO. 15
Sherwood Elementary School
Legal Description
Area 8
Tracts 6, 7 and 8, Richmond Beach Garden Tracts, according to the plat
thereof recorded in Volume 8 of Plats, on page 54, records of Snohomish
County, Washington.
Containing 13. 62+ acres.
106th Avenue West
co
m
m
r+
(A
0
c
r+
:r
m
0
r+
m
x
::r
cr
V46 04
- - - - - — - - - - - - - — -
ST. Ivor 0 E 7j St
2
io Ij
&o4 1*
�VGME Exhibit 2
IMAM Jfm r% a,,,
51 6
PLAT
12ti `1 -4
Wit! 178.:,
0141
NO.
1345 17
.10145 ---
It,
'kp
A 4'.
7o
Go
to, ADD.
. . . . . . . . . . . .
Ic R11 H ND*.BEACH -Z
0
.6'
2
>
2 .
16 p <
Bq
LLJ
46
31
19 10
GA 'TRACTS
0411
(40
18
T fa F
7 0
3 4
(4%
�2 4 5' 6 - a r ' . : I 1 :..17 . . "': 0
41' SPA3 &P. 27;.;7Z� .. '.' �i 1--,.. 1: 11 '; - '�" ... —
V
S. R .0 D-
4- r
Its
t5as 1 115 - I .- ! * Il.r. -; , ". .. Ij
.91111 law
JBjo 4 75 '-� 'p . I '. - ' ; .
14; o� is 7
15 4 12 11 3)
TR
3!C(12 1- L
Nil S us III . (1) 6o
ST. s w '3607 . IM5Q
ItIcs 5441
6o 121152 E -WRI 14o
NO
0
In, 6
hp
2
76
2Z .7
10 10 ejl?oo
L ul
6
-11. 4 Ir 61118 1. Z L o o
zj-j '4
15
4 oo
It)
12. Q, 0
m RD.
2 14
? 2'2 23 24 26 o
2 . I � .'I'*
9361 .2-815
-9 (5-75) 001 2.005
(I )slul (2)
I w
z
lb 17 0
-UL -1 ml e oo4 N CID 436 41- -"CUL. E
3 T_J� ISLAS- 'lo-, 12541
-014- lGo-
10
4 PIP,' J INE W. 7
— . . . . . . it
p -51 3, � 14
so C\I 236TH L. Ws Do t m�l
Ld r 54. -1 5s.1) 17.21 11.1-L 4 so '4 12
21,sslp ;;t: 14$.
k -die
11"2z
1111 U)
4 11 15 'do E N 3 —6-0
3-015 9 5<
2 LLJ 014
Oil? >14 >
J -
-, jv--'
L-n
30/6 -j 42 -
- I �'? , . a.
0 r, < . - 15'
j-" -we —,Fo—oz 3 ir
3.og 3.004 4 10 � its
joid z 2 ILL
59 cn 0
c
C" a
S'W' r1i
A M IKYII<
TO BE COMPLETED BY APPLICANT
B. ENVIRONMENTAL ELEMENTS
1. EARTH
a. General description of the site (underline one): Flat, rolling, hilly, steep slopes,
mountainous, other.
b. What is the steepest slope on the site (approximate percent slope)?
The school site is generally flat. Along the eastern boundary of the site, there are
steep, sand bank slopes approaching approximately 70 degrees. The proposed work
will not disturb the eastern portions of the site.
c. What general types of soils are found on the site (for example, clay, sand, gravel, peat,
and muck)? If you know the classification of agricultural soils, specify them and note
any prime farmland.
The Alderwood-Urban land unit consists of approximately 60 percent gravelly sand
loam and about 25 percent urban land. The Alderwood soil is formed in glacial till,
is moderately deep over a hardpan, and is moderately well drained. Permeability of
the Alderwood soil is moderately rapid above the hardpan and very slow through it.
Runoff is slow and the hazard of water erosion is slight. Typically, this soil has a
gravelly-sandy-loarn surface layer 7 inches thick. The subsoil is very gravelly -sandy -
loam 28 inches thick. The substratum is weakly cemented to 60 inches.
The Urban land soil classification consists of areas that are covered by streets,
buildings, parking lots, and other structures that obscure or alter the soils so that
identification is not possible.
McKenna gravelly silt loam, 0-8 percent slopes, is a moderately deep, poorly drained
soil found in depressional areas and drainage ways on till plains. Permeability of this
soil is slow. Runoff is slow and the hazard of erosion is slight.
d. Are there surface indications or history of unstable soils in the immediate vicinity? If
so, describe.
A small amount of soil erosion has occurred at the base of the steep slope but it does
not impact the stability of the slope and is not in the area where the proposed work
will take place.
e. Describe the purpose, type, and approximate quantities of any filling or grading
proposed. Indicate source of fill.
Approximately 500 C.Y. of soil will be moved on -site in conjunction with the
construction of the asphalt walking -path. The soil that will be removed would be
redistributed to low places on the field and along the northern perimeter of the site.
f. Could erosion occur as a result of clearing, construction, or use? If so, generally
describe.
Erosion is unlikely to occur because of the small amount of grading and the
porous/granular soils found on site.
g. About what percent of the site will be covered with impervious surfaces after project
construction (for example, asphalt or buildings)?
Approximately 21 percent of the site will be covered with impervious surfaces after
project construction. At this time, approximately 20 percent of the site is covered with
impervious surface. The asphalt path will be 7,080 square feet of paving, and brick
paver area totals approximately 1,000 square feet.
h. Proposed measures to reduce or control erosion, or other impacts to the earth, if any:
Erosion control measures will be implemented during the construction process in
accordance with an erosion control plan approved by the City of Edmonds
Engineering Department.
2. AIR
a. What types of emissions to the air would result from the proposal (i.e., dust,
automobile, odors, industrial wood smoke) during construction and when the project is
completed? If any, generally describe and give approximate quantities if known.
A small amount of dust may be in the air during the construction of the asphalt path
but will be contained within the boundaries of the subject property if -it does occur.
b. Are there any off -site sources of emissions or odor that may affect your proposal? If
so, generally describe.
I me
c. Proposed measures to reduce or control emissions or other impacts to air, if any:
None proposed.
3. WATER
a. Surface Water
1) Is there any surface water body on or in the immediate vicinity of the site (including
year-round and seasonal streams, saltwater, lakes, ponds, and wetlands)? If yes,
describe type and provide names. If appropriate, state what stream or river it flows
into.
None
2) Will the project require any work over, in or adjacent to (within 200 feet) the
described waters? If yes, please describe and attach available plans.
Ime
3) Estimate the amount of fill and dredge material that would be placed in or removed
from surface water or wetlands and indicate the area of the site that would be
affected. Indicate the source of fill material.
N/A
4) Will the proposal require surface water withdrawals or diversions? Give general
description, purpose, and approximate quantities if known.
No
5) Does the proposal lie within a 100-year floodplain? If so, note location on the site
plan.
No
6) Does the proposal involve any discharges of waste materials to surface waters? If so,
describe the type of waste and anticipated volume of discharge.
No
b. Ground
1) Will ground water be withdrawn, or will water be discharged to ground water? Give
general description, purpose, and approximate quantities if known.
No
2) Describe waste material that will be discharged into the ground from septic tanks or
other sources, if any (for example: Domestic sewage; industrial, containing the
following chemicals ... ; agricultural; etc.). Describe the general size of the system,
the number of such systems, the number of houses to be served (if applicable), or the
number of animals or humans the system(s) are expected to serve.
None
c. Water Runoff (including storm water)
1) Describe the source of runoff (including storm water) and method of collection and
disposal, if any (include quantities, if known). Where will this water flow? Will this
water flow into other waters? If so, describe.
The majority of the storm water runoff from the asphalt path will infiltrate into the
ground. The excess that flows during periods of heavy rain will flow over land in a
S.E. to N.W. direction across the grass field and eventually will collect in an
infiltration trench along the west end of the field. The goal of the proposed design is
to avoid any storm water from entering the city's pipe system.
2) Could waste materials enter ground or surface waters? If so, generally describe.
iffle
d. Proposed measures to reduce or control surface, ground, and runoff water impacts, if
any:
The majority of the storm water runoff from the asphalt path will infiltrate into the
ground. The excess that flows during periods of heavy rain will flow over land in a
S.E. to N.W. direction across the grass field and eventually will collect in an
infiltration trench along the west end of the field. The goal of the proposed design is
to avoid any storm water from entering the city's pipe system.
4. PLANTS
a. Check or underline types of vegetation found on the site:
deciduous tree: alder, maple, aspen, other
evergreen tree: fir, cedar, pine, other
shrubs
grass
pasture
crop or grain
wet soil plants: cattail, buttercup, bulrush, skunk cabbage, other
water plants: water lily, eelgrass, milfoil, other
other types of vegetation
b. What kind and amount of vegetation will be removed or altered?
A small amount of the existing grass play area play area will be removed in order to
construct the proposed asphalt path.
c. List threatened or endangered species known to be on or near the site, if any:
None
d. Proposed landscaping, use of native plants, or other measures to preserve or enhance
vegetation on the site, if any:
None
5. ANIMALS
a. Underline any birds and animals which have been observed on or near the site or are
known to be on or near the site:
Birds: hawk, heron, eagle, songbirds, other
Mammals: deer, bear, elk, beaver, other
Fish: bass, salmon, trout, herring, shellfish, other
b. List any threatened or endangered species known to be on or near the site.
None
c. Is the site part of a migration route? If so, explain.
No
d. Proposed measures to preserve or enhance wildlife, if any:
None
6. ENERGY AND NATURAL RESOURCES
a. What kinds of energy (electric, natural gas, oil, wood stove, solar) will be used to meet
the completed project's energy needs? Describe whether it will be used for heating,
manufacturing, etc.
The proposed project are improvements to the outdoor recreational facilities at the
Sherwood Elementary School. Gasoline will be consumed to continue to mow the
turf.
b. Would your project affect the potential use of solar energy by adjacent properties? If
so, generally describe.
No
c. What kinds of energy conservation features are included in the plans of this proposal?
List of other proposed measures to reduce or control energy impacts, if any:
None
7. ENVIRONMENTAL HEALTH
a. Are there any environmental health hazards, including exposure to toxic chemicals,
risk of fire and explosion, spill, or hazardous waste, that could occur as a result of this
proposal? If so, describe.
No
1) Describe special emergency services that might be required.
None anticipated.
2) Proposed measures to reduce or control environmental health hazards, if any:
N/A
b. Noise
1) What types of noise exist in the area which may affect your project (for example:
traffic, equipment, operation, aircraft, other?
None
2) What types and levels of noise would be created by or associated with the project on a
short-term or a long- term basis (for example: traffic, construction, operation, other)?
Indicate what hours noise would come from the site.
Short-term impacts associated with construction noise may occur during the construction
period. The City of Edmonds allows construction activity to occur between 7am - lopm
on weekdays and 10am - 6prn on weekends and holidays.
3) Proposed measures to reduce or control noise impacts, if any:
None
8. LAND AND SHORELINE USE
a. What is the current use of the site and adjacent properties?
Sherwood Elementary School has existed on this site since 1967. Single-family
residences are located to the north, west, east, and south.
A
b. Has the site been used for agriculture? If so, describe.
I WC
c. Describe any structures on the site.
The subject property features 3 separate buildings with classrooms, connected by a
covered walkway and a gymnasium. In addition there is a covered basketball area. A
short section of 12' high fence will separate the play equipment and the field area.
d. Will any structures be demolished? If so, what?
No
e. What is the current zoning classification of the site?
The current zoning of this site is Public Use.
f. What is the current comprehensive plan designation of the site?
Public Facility
g. If applicable, what is the current shoreline master program designation of the site?
N/A
h. Has any part of the site been classified as an "environmentally sensitive" area? If so,
specify.
No
i. Approximately how many people would reside or work in the completed project?
No change in student or staff population would occur as a result of this project
j. Approximately how many people would the completed project displace?
None
k. Proposed measures to avoid or reduce displacement impacts, if any:
N/A
f
1. Proposed measures to ensure the proposal is compatible with existing and projected
land uses and plans, if any:
The proposed project does not change the existing land uses on the subject property.
9. HOUSING
a. Approximately how many units would be provided, if any?
None
b. Approximately how many units, if any, would be eliminated? Indicate whether high,
middle, or low-income housing.
None
c. Proposed measures to reduce or control housing impacts, if any:
N/A
10. AESTHETICS
a. What is the tallest height of any proposed structure(s), not including antennas; what is
the principal exterior building material(s) proposed?
A 12' high fence will be located along the field from the play area to separate the field
from the play equipment.
b. What views in the immediate vicinity would be altered or obstructed?
None
c. Proposed measures to reduce or control aesthetic impacts, if any:
N/A
11. LIGHT AND GLARE
a. What type of light or glare will the proposal produce? What time of day would it
mainly occur?
None
b. Could light or glare from the finished project be a safety hazard or interfere with views?
IM
c. What existing off -site sources of light or glare may affect your proposal?
None
d. Proposed measures to reduce or control light and glare impacts, if any:
Iffral
12. RECREATION
a. What designated and informal recreational opportunities are in the immediate vicinity?
The Sherwood school site represents one of the only designed recreational areas in the
neighborhood. Additional recreational opportunities in the area include Former
Woodway High School, 23200 100" Ave. West, located southeast of the site; and old
Woodway Elementary School, 23700 104th Ave. West, located south of the site.
b. Would the proposed project displace any existing recreational uses? If so, describe.
No
c. Proposed measures to reduce or control impacts on recreation, including opportunities
to be provided by the project or applicant, if any:
No
13. HISTORIC AND CULTURAL PRESERVATION
a. Are there any places or objects listed on, or proposed for, national, state, or local
preservation registers known to be on or next to the site? If so, generally describe.
we
b. Generally describe any landmarks or evidence of historic, archaeological, scientific, or
cultural importance known to be on or next to the site?
None
c. Proposed measures to reduce or control impacts, if any:
N/A
14. TRANSPORTATION
a. Identify public streets and highways serving the site, and describe proposed access to
the existing street system. Show on site plans, if any.
The subject property is bordered by 106' Ave. West on the west and 228 1h Street SW
to the north. There would be no change to the existing access to the site as a result of
the proposed project.
b. Is site currently served by public transit? If not, what is the approximate distance to
the nearest transit stop?
The site is not served by public transit. The nearest transit stop is located at Edmonds
Way and 226' St. Southwest.
c. How may parking spaces would the completed project have? How many would the
project eliminate?
Approximately 75 parking spaces are located on the subject property. There will be
no additional parking provided or spaces removed in conjunction with the project.
d. Will the proposal require any new roads or streets, or improvements to existing roads
or streets, not including driveways? If so, generally describe (indicate whether public
or private).
No
e. Will the project use (or occur in the immediate vicinity of) water, rail, or air
transportation? If so, generally describe.
to
f. How many vehicular trips per day would be generated by the completed project? If
known, indicate when peak volumes would occur.
There are no additional vehicular trips associated with the field improvements.
g. Proposed measures to reduce or control transportation impacts, if any:
N/A
15. PUBLIC SERVICES
a. Would the project result in an increased need for public services (for example: fire
protection, police protection, health care, schools, other)? If so, generally describe:
I we
b. Proposed measures to reduce or control direct impacts on public services, if any.
N/A
16. UTILITIES
a. Underline utilities currently available at the site:
Electricily, natural gas, water, refuse service, telephone, sanitary sewer, septic system, other.
b. Describe the utilities that are proposed for the project, the utility providing the
service, and the general construction activities on the site or in the immediate vicinity
which might be needed.
None
C. SIGNATURE
The above answers are true and complete to the best of my knowledge. I understand that the
lead agency is relying on them to make its decision.
Signature:
Br
,;�K. Carlstad, Director
Edmonds School District No. 15
Datesubmitted: &-2-1'-C)O
EDMONDS
EDMONDS SCHOOL DISTRICT CAPITAL
PROJECTS
20420 - 68th Avenue West OFFICE
Is Lynnwood, Washington 98036-7400
SCHQ)L (206) 670-7166 FAX (206) 670-7171
D I S T R I C T
Includes Brier, Edmonds, Lynnwood, Mountlake Terrace, and Woodway
September 1, 1995
Paul Mar
City of Edmonds
250 - 5th Ave. N.
Edmonds, WA 98020
Attention:
Subject:
Regarding
Dear Mr. Mar,
Paul Mar
Maplewood, Sherwood and Westgate Elementary Schools
State Agency & Insurance Information
V S I'V
IR - C
SEP
Edmonds School District No. 15 is a public school district; considered a State Municipal
Corporation per RCW 39.50.010 (3).
The District's property and liability coverage is through Puget Sound Schools Risk Management
Pool with a limit of $10 million per occurrence. A certificate showing proof of this coverage is
available at your request.
Please contact me if you have any questions. Thank you for your time.
Sin erelly,
I
teve Hoyt
Capital Projects Administrator
cc: Steve Matsudaira, Mahlurn & Nordfors
Trevor Hart, Edmonds School District
enclosure
deb\sma11wks\bidpk3a\agency1t
OUR MISSION e
To ADVOCATE for all students by PROVIDING a learning environment which EMPOWERS students, staff and the community to MAXD4LZE their
personal, creative and academid potential in order to BECOME lifelong learners and responsible world citizens.
EDMONDS
EDIVIONDS SCHOOL DISTRICT CAPITAL
PROJECTS
20420 - 68th Avenue West OFECE
Lynnwood, Washington 98036-7400
SCH(OL (206) 670-7166 FAX (206) 670-7171
D I S T R I C T
Includes Brier, Edmonds, Lynnwood, Mountlake Terrace, and Woodway
August 31, 1995 Rr..CEIVED
SEP -
Paul Mar SE-R,,110ES
,�C)t,",p,ijN1,TY
City of Edmonds 01 or:
_-CTO8
250 - 5th Ave. N.
Edmonds, WA 98020
Attention: Paul Mar
Subject: Maplewood, Sherwood and Westgate Elementary Schools
Regarding: Performance Bonds
Dear Mr. Mar,
On behalf of the Capital Projects Office of the Edmonds School District, I am requesting relief of the
Performance Bond requirements for the improvements to the above mentioned schools. The work
includes improvements to public right of ways, parking, and vehicular access and is in the best interest of
the District to complete in a timely manner. The Edmonds School District is a public agency and
requires the contractor to obtain performance and payment bonds prior to beginning work.
In addition, it is my understanding that Senate Bill 5858 prohibits a city from securing a performance
bond as a permit requirement on a construction project. According to Senate Bill 5858, a construction
project includes "street alteration, pedestrian or vehicular access alteration, or other amenities ...
associated with the project". I have included a copy of this bill for your review. Please review this
information in relation to our request for exemption from the performance bond requirements.
Please contact me after you have read this information. Thank you for your time.
Sincerely,
ReborjaMR!!d�
670-7172
cc: Steve Matsudaira, Mahlum & Nordfors
Laurie Pfaff, SvR Design Company
Trevor Hart, Edmonds School District
enclosure
deb\sma11wks\bidpk3&\perfbd1t
*OUR MISSION*
To ADVOCATE for all students by PROVIDING a leaming environment which EMPOWERS students, staff and the community to MAXD4[ZE their
personal, creative and academic potential in order to BECOME lifelong learners and responsible world citizens.
CERTIFICATION OF ENROLLMENT
SUBSTITUTE SENATE BILL 5858
Chapter 439, Laws of 1993
.53rd Legislature
1993 Regular Session
NO SECURITY REQUIRED FOR ISSUANCE OF BUILDING PERMIT
TO GOVERNMENT UNIT
EFFECTIVE DATE: 7/25/93
Passed by the Senate April 18,
1993
YEAS 42 NAYS 0
. JOEL PRITCHARD
President of the Senate
Passed by the House April 12,
1993
YEAS 93 NAYS 2
BRIAN EBERSOLE
Speaker of the
House of Representatives
Approved'May 15, 1993
CERTIFICATE
I. Marty Brown, Secretary of
the Senate of the State of
Washington, do hereby certify
that the . aftached is -
SUBSTITUTE SENATE BILL 5858 as
passed by the Senate and the
House of Representatives on
the dates hereon set forth.
MARTY BROWN
Secretary
FILED
May 15, 1993.- 1:54 p.m.
MIKE LOWRY
Governor of the State
Washington
of
SUBSTITUTE SE14ATE BILL 5858
AS AMENDED BY THE HOUSE
Secretary of State
State of Washington
Passed Legislature - 1993 Regular Session
State of Washington 53rd Legislature 1993 Regular Session
By Senate Committee on Government Operations (originally sponsored by
Senator Cantu)
Read first time 03/03/93.
AN AC . T Relating to permits for local government units, building
2 construction projects; adding a new section to chapter 35.21 RCW;
3 adding a new section to chapter 35A.21 RCW; and adding a new section
4 to chapter 36.32 RCW.
5 BE IT ENACTED BY THE LEGISLATURE OF THE STATEOF WASHINGTON:
6 NEW SECTION., Sec. 1. A new section is added to chapter 35.21
7 RCW to read as follows: - it of local
8 A city or town may not require any state agency or un
.9 g overnment to secure the performance of a permit requirement with a
10 surety bond or other financial security device, including cash or
11 assigned account, as a condition of issuing a permit to that unit of.
12 local government for a building construction project.
13 As used in this section, "building construction project',
14 includes, in addition to its usual meaning, associated landscaping,
15 street alteration, pedestrian or vehicular access alteration, or
16 other amenities or alterations necessarily associated with the
17 proj ect.
P. 1
SSB 5858.SL
1 NEW SECTION. Sec. 2. A new section is added to chapter 35A.21
2 RCW to read as follows:
3 A. code city may
not require any state agency or unit
of local
4 government to secure
the performance of a permit requirement with a
5 surety bond or other
financial security device, including
cash or
6 assigned account, as
a condition of issuing a permit to that
unit of
7 local government for
a building construction project.
8 As used in this
section, "building ..construction
project"
9 includes, in addition to its usual meaning, associated landscaping,
10 street alteration, pedestrian or vehicular access alteration, or
11 other amenities or alterations necessarily associated with the
12 project.
13. NEW SECTION. Sec. 3. A new section is added to chapter 36.32
14 RCW.to read as follows-:
15 A county legislative authority may not require any state agency
16 or unit of local government to secure the performance of a permit
17 requirement with a surety bond or other financial security device,'
18 including cash or assigned account, as a condition of issuing a
19 permit to that unit of local government for a building construction
20 project.
21 As used in this section, "building construction project"
22� includes, in addition to its usual meaning, associated landscaping,
23 street alteration, pedesttian or vehicular access alteration, or
24 other amenities or alterations necessarily associated with the
25 project.
890 - I C) 9
CITY OF EDMONDS LAURA M. HALL
250 - 5TH AVE. N. - EDMONDS, WA 98020 - (206) 771-0220 - FAX (206) 771-0221 MAYOR
COMMUNITY SERVICES DEPARTMENT
Public Works e Planning e Parks and Recreation @ Engineering
September 1, 1995
Debora Reddy
Edmonds School District #15
20420 68th Ave. W.
Lynnwood WA 98036-7400
Dear Debora:
I am writing to respond to your request for relief of the performance bond
requirements for the construction projects at Maplewood, Sherwood, and
Westgate Elementary Schools.
Upon discussion with our staff and legal counsel, based on the letter dated
September 1 st we received via fax from Mr. Steve HoA the City considers this
letter sufficient evidence to satisfy the City's performance bond requirement..
The City therefore deems that you have satisfied this condition towards
obtaining your building permit for the above noted projects. Please call if you
have questions. '
Sincerely,
Paul Mar
Director
cc-
/�cott Snyder, City Attorney
Jeannine Graf, Building Official
Gordy Hyde, Engineering Coordinator
You therefore have satisfied
0 Incorporated August 11, 1890 0
Sister Cities- International — Hekinan, Japan
City of Edmonds
Critical Area Notice of Decision
Applicant:
670(ro"Jj J.
Property Owner:
S��Pwo-cp
Critical Area File
0C) -7,8
Permit Number:
201-2--- 0
Site Location:
10(9 a, f4j".e.
Parcel Number:
0 o 00006o c)
Project Description:
KConditional Waiver. No critical area report is required for the proj * ect described above.
I . Y�- There will be no alteration of a -Critical Area or its required buffer.
The proposal is an �Ilowed activity pursuant to ECDC 23.40.220, 23.50.220, and/or
23.80.040.
The proposal is exempt pursuant to ECDC 23.40.230.
F� Erosion Hazard. Project is within erosion hazard area. Applicant must prepare an erosion and
sediment control plan in compliance with ECDC 18.30.
F� Critical Area Report Required. The proposed project is within a critical area and/or a critical area
buffer and a critical area report is required. A critical area report has been submitted and evaluated
for compliance with the following criteria pursuant to ECDC 23.40.160:
I The proposal minimizes the impact on critical areas in accordance with ECDC 23.40-.120,
Mitigation sequencing;
2. The proposal does not pose an unreasonable threat to the public health, safety, or welfare
on or off the development proposal site;
3. The proposal is consistent with the general purposes of this title and the public interest;
4. Any alterations permitted to the critical area are mitigated in accordancewith ECDC
23.40. 110, Mitigation requirements.
5. The proposal protects the critical area functions and values consistent with the best
available science and results in no net loss of critical ftinctions and values; and
6. The proposal is consistent with other applicable regulations and standards.
F� Unfavorable Critical Area Decision. The proposed project is not exempt or does not adequately
mitigate its impacts on critical areas and/or does not comply with the criteria in ECDC 23.40.160 and
the provisions of the City of Edmonds critical area regulations. See attached findings of
noncompliance. IM
19 Favorable Critical Area Decision. The proposed project as described above and as shown on the
attached site plan meets or is exempt from the criteria in' ECDC 23.40.160, Review Criteria, and
complies with the applicable provisions of the City of Edmonds critical area regulations. Any
subsequent changes to the proposal shall void this decision pending re -review of the proposal.
Fj Conditions. Criti cal Area specific condition(s) have been applied to the permit number referenced
above. See referenced permit number for specific condition(s).
�4- C tcq ( �A 10)m C616w7v�
Reviewei Signature /
it 6—
Date
Appeals: Any decision to approve, condition, or deny a development proposal or other activity based on the
requirements of critical area regulations may be appealed according to, and as part of, the appeal procedure, if any,
for the permit or approval involved.
Revised 12/16/2010
0,
I(L
CA FILE NO.
Critical Areas Checklist
Site Information (Wds/topography/hydri)log�/vegetation)
1. Site Addressfl-ocatiow 22901 106th Avenue Mest, Edmonds
2. Property Tax Account Number 5546-000-006-0004
3. Approximate Site Size (acres or square feet): 13.6 acres
4. Is this site currently developed? --!-yes; — no_
If yes; how is site developed?_.��wo�OdE 1�ementa �rS�choo�l( bu i I t i n 1967)
5. Describe the geoetal site topography. Check all that apply.
Tlat: 1= than 5-feet elevation change over entire site.
Rolling: slopes on site generally less than 15% (a vertical rise of 10-feet over a
horizontal distance of 66-feet).
slopes presenton she of worethan 15%andleath=30% (aveiticalrise,
of 10-feet over a horbontal distaum of 33 to M4bet).
SteW, grades of9reater don 30% present on site (a vertical rise of 10-feet over a
horWoutal &stance of lea than 334bet).
Odair V* ease
6. Sift Contains 2rCU Of YCW-MW staldi Water. �jo Approx. Depth:
7. She Contains 'UM ofseasmol standitig water. Aj 0 Approx- Depdc
What sats*S) of die yew?
600wo of a water course.
9. Site contaks atek or an ava wbere water flows across die gmunds surface?. Flows am yew -
round? -TO Flows am seasonal? (Whatimeofycul
10.. Site is ptinwily: 6vested 'Meadow ;shrubs Mixid
urban landscapid QawnAuubs etc)
11. Obvious wedand is present on she:
..... i--��Cftystdruse F
Siteii7AneV
marpw zoalype(sr.
Imp
or ck., Jd�vmdsnd pt an zitg4k.,
.1. 01.
0
tk§6widaA04k=Wtaxth zubsU� hadsli& baned
J
a"em"
V k
%;
9 9
City of Edmonds
Critical Areas,- -CheckliSt -
Ile Critical Areas Checklist contained,4011 mit it to the
this fOnn is to be filled Out by any person City-- ql* will
".Mview the cheddistinake-a precursory site
preparing a Development Permit visk'and make'a dcWnnination of the
Applicatio�. for the City of Ednxxws subsequent stePs necessary to complete a
to histher submittal of
development perinft applicatim.
permit to the City.
With a Aped copy of this &rm, the
Ile purpose of the Checklist is to enable applicant shiould also, submit a!�� amp
City staff to determine whcdmr=y or plot plan for indivau—al lots of dr.
potential Critical Ams are or any be with enough detail that City staff can Ifind,
present on the subiect propedy. Ime and identify the SuMjed parcd(s) hi
infonnation needed to complete the additiot4 the appoeWshall ' -
bidude
Chadmist should be ew9y available fiam otber pertinent Wamoon (er, dte
Observations of the site or data available at plat4 topography maN etc.),orstu4m In
City Hall (Critical Ams kmentoem, aWs'. -00
or soil sumar). qjUnction -,Ath thk C6� to,iisft,
Staff in con4fiethM their 1prerunhu"
asussinent.of the sfte�.
An applicant. or Nsnwqx
mug fill out -die checklist, Againddate
I have completed die attached Cdfical Ana Cheddist and MW dal-
1511c� - the 1� 4 . .. * =Swm pwAded are.,
Ito ..my kwMedge.(fill vA die qVM
pnte�dluiii� below).
Owner I Applicant-
fW*pt Representative:
W 4
-Bret M. Carlstad
20420 68th Avenue W 2042'0 68th Avenue
West
&red Addn=
fted Ad&=
Lynnwood, WA' 98036-7400 6170-7000 Lynnwood, WA 98036-7400 6 Aft i , 3
W
City. state. ZIP Phone
Phone"
Date
DatW
M
City of Edmonds
Critical Areas Determination
Applicant.: Bret Carlstad Determination #: CA-95-78
Edmonds School bistrict
Project Name: Permit Number:
Site Location: �22901 106th Avenue West Property Tax Acct 5546-000-006-0
P I reject Description
t
non -project specific
A site inspection of the property has revealed a lot developed with an elementary school. The
western portion of the lot is nearly flat while an area at the eastern edge of the property slopes up
steeply to the east. The steep bank on the east side appears to slope upward at a rate greater than
40%.
Based on the above findings, it is.determined that there is potentially a steep slope critical area on
or adjacent to the site. A Critical Areas Study is required to delineate the boundaries of this
potential critical areas, the buffers and setbacks. For the steep slopes, a licensed surveyor must
create a topographic map of the site which indicates' all areas which slope 40% or more and have
a vertical gain of 20 feet or more within the 40% slopes. The map must also show the location of
the steep slope buffers and setbacks. The surveyor must also create legal descriptions for the
critical areas and the buffers. The critical area study must be created through a three party
contract between the applicant, the City and the consultant
I
If the property owner wishes to apply for a specific development permit which they feel would
not impact the Critical Areas located on the site, they may submit their proposal to the Planning
Department for review. If the Planning Department finds that the proposed development permit
will not adversely impact a Critical Areas or its buffers, a conditional waiver may be issued on a
project by project basis.
John Bissell
Name (-Si n5aure
July 13. 1995
Date
1�p
City of Edmonds
Critical Area Notice of Decision
Applicant:
,d,�to
C 5- - (�)
, Ild 5
Property Owner:
Critical Area File
C(ek (9� S70 -7
Permit Number:
Site Location:
Z-2-cl()( 106* aue.
4
Parcel Number:
I (Do 0 00 6oc;-
Project Descriptio . n:
ot VV CA 0V -Uk-C 4- _Cj-n .6
�Zrlconditional Waiver. No critical area report is required for the project described above.
I . KL.There will be no alteration of a -Critical Area or its required buffer.
The proposal is an illowed activity pursuant to ECDC 23.40.220, 23.50.220, and/or
23.80.040.
The proposal is exempt pursuant to ECDC 23.40.230.
F Erosion Hazard. Project is within erosion hazard area. Applicant must prepare an erosion and
sediment control plan in compliance with ECDC 18.30.
F Critical Area Report Required'. The proposed project is within a critical area and/or a critical area
buffer and a critical area report is required. A critical area report has been submitted and evaluated
for compliance with the following criteria pursuant to ECDC 23.40.160:
I The proposal minimizes the impact on critical areas in accordance with ECDC 23.40-.120,
Mitigation sequencing;
2. The proposal does not pose an unreasonable threat to the public health, safety, or welfare
on or off the development proposal site;
3. The proposal is consistent with the general purposes of this title and the public interest;
4. Any alterations permitted to the critical area are mitigated in accordancewith ECDC
23.40. 110, Mitigation requirements.
5. The proposal protects the critical area functions and values consistent with the best
available science and results in no net loss of critical functions and values; and
6. The proposal is consistent with other applicable regulations and standards.
Fj Unfavorable Critical Area Decision. The proposed project is not exempt or does not adequately
mitigate its impacts on critical areas and/or does not comply with the criteria in ECDC 23.40.160 and
the provisions of the City of Edmonds critical area regulations. See attached findings of
noncompliance.
0-Favorable Critical Area Decision. The proposed project as described above and as shown on the
attached site plan meets or is exempt from the criteria ih ECDC 23.40.160, Review Criteria, and
complies with the applicable provisions of the City of Edmonds critical area regulations. Any
subsequent changes to the proposal shall void this decision pending re -review of the proposal.
F1 Conditions. Criti cal Area specific condition(s) have been applied to the permit number referenced
above. See referenced permit number for specific condition(s).
A, C&
Reviewer I
Signature/
Date
Appeals: Any decision to approve, condition, or deny a development proposal or other activity based on the
requirements of critical area regulations may be appealed according to, and as part of, the appeal procedure, if any,
for the permit or approval involved.
Revised 12/16/2010
CITY OF EDMONDS
CONSTRUCTION PERMIT APPLICATION
OWNER NAME/NAME OF BUSINESS
ir
W MAILING ADDRESS
z
0
CITY ZIP ONE
r<,A,v� iv
NAME
r
/V
ADDRESS
cr
CITY ZIP TELEPHONE
I INAME
—:t
*�� (. 1(:-_,,7110 V 'a "; oe,�;r
cr ADDRESS
0
U -?,
z
z CITY
ZIP/
TELEPHONE
0
7,
STATE LICENSE NUMBER
EXPIRATION DATE
CHECKED BY
/Y 4.
(-. / 4 1
1--) 1�,// -� �,)� ��_ sr ) � I o 0
bk 6—
Z, I LEGAL DESCRIPTION OF PROPERTY - INCLUDE ALL EASEVEN1fS
PROPERTY TAX ACCOUNT PARCEL NO.
NEW
RESIDENTIAL
PLUMBING / MECH
ADDITION
COMMERCIAL
o COMPLIANCE OR
CHANGE OF USE
REMODEL
APARTMENT
SIGN
REPAIR
GRADING CYDS
FENCE
X
( — — FT)
DEMOLISH
TANK OTHER
GARAGE
CARPORT
RETAINING WALL
E] 'R'ENE'WAL 414-
Z
0
ROCKERY
P: (TYPE OF USE, BUSINESS
OR ACTIVITY) EXPLAIN:
U
V)
w NUMBER
0
NUMBER OF
CRITICAL
M OF
DWELLING
AREAS
o STORIES
UNITS
NUMBER
DESCRIBE WORK TO BE DONE
HEAT SOURCE GLAZING % LOT SLOPE %
PLAN CHECK NO: NESTED DATE
I I -;,; -) - I
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO
BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC
:i DOMAIN (CURBS,SIDEWALKS, DRIVEWAYS, MARQUEES,ETC.) WILL REQUIRE
SEPARATE PERMISSION.
W PERMIT APPLICATION: 180 DAYS
I PERMIT LIMIT: I YEAR - PROVIDED WORK IS STARTED WITHIN 180 DAYS
in
'APPLICANT, ON BEHALF OF HIS OR HER SPOUSE, HEIRS, ASSIGNS AND SUCCESORS
_j
2 IN INTEREST. AGREES TO INDEMNIFY, DEFEND AND HOLD HARMLESS THE CITY OF
Cc EDMONDS, WASHINGTON, ITS OFFICIALS, EMPLOYEES, AND AGENTS FROM ANY AND
x ALL CLAIMS FOR DAMAGES OF WHATEVER NATURE, ARISING DIRECTLY OR INDIRECTLY
a FROM THE ISSUANCE OF THIS PERMIT. ISSUANCE OF THIS PERMIT SHALL NOT BE
_j
0 DEEMEDTO MODIFY, WAIVE OR REDUCEANY REQUIREMENTOF ANY CITY ORDINANCE
-1 NOR LIMIT IN ANYWAY THE CITY'S ABILITY TO ENFORCE ANY ORDINANCE PROVISION. -
I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION; THAT THE INFORMATION
GIVEN IS CORRECTAND T I — T --
PERMIT EXPIRES
USE PERMIT
ZONE NUMBER 99dqa;9
JOB SUITE/APT#
ADDRESS
LEGAL DESCRIPTION CHECK SUBDIVISION NO. LID NO.
PUBLIC RIGHT OF WAY PER OFFICIAL STREET MAP
EXISTING — REQUIRED DEDICATION
PROPOSED
METER SIZE I LINE SIZE I NO. OF FIXTURES
REMARKS
ENGINEERING MEMO DATED
TESCP Approved
0
AW Permit Required
0
Street Use Permit Req-d
0
Inspection Required
0
sidewalk Required
0
PRV REQUIRED
YES 0 NO 0
z
Fr
z
z
a
z
W
REVIEWED BY
FIRE MEMO DATED C REVIEWED BY
I cc
pw�ljc (6A*CT1;D 91 .
I VARIANCE OR CU I / ADB# SHORE7E It
SEPA REVIEW SIGN AREA HEIGHT
COMPLETE I EXEMPT ALLOWED , PROPOSED ALLOWED , PROPOSED
EXP
LOT COVERAGE REQUIRED SETBACKS (FT.) PROPOSED SETBACKS (FT.)
ALLOWED PROPOSED FRONT SIDE REAR FRONT L/R SIDE REAR
z
z
LOT AREA PLANNING REVIEW BY DATE _1
1 101
CHECKEDBY ITYr- OF CONSTRUCTION CODE OCCUPANT
:::�j
/ ", GROUP
SPECIAL INSPECTOR] AREA OCCUPA)Tr
REQUIRED 0 YE LOAD
REMARKS
PROG RESS INSPECTIONS PER UBC 108
FINAL INSPECTION REQUIRED
IVALUATION FEE
PLAN CHECK FEE
BUILDING
PLUMBING
MECHANICAL
GRADING/FILL
STATE SURCHARGE
STORM DRAINAGE FEES
ENG. INSPECTION FEE
PLAN CHECK DEPOSIT
TOTAL AMOUNT DUE
, — I — DULY AUTHORIZED AGENT OF
THE OWNER. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUC. APPLICATION APPROVAL
TION: AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED CALL This application is not a permit until signed by the
Building Official or his/her Deputy: and Fees are paid, and
IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO FOR INSPECTION receipt is acknowledged in space provided.
WORKMEN'S COMPENSAT40N INSURANCE AND RCW 18.27.
'ISF6�N�ARE,(O :k4
5�01`1 DATE SIGNED OFFIC I NA�
DATE
7NI4
(425)
771-0220
YA?1;
1'�E '
RELEA D BY 0 E
ATTENTION
tl
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL
A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFI-
CATE OF OCCUPANCY HAS BEEN GRANTED. UBC SECTION 109 ORIGINAL - FILE YELLOW - INSPECTOR
5/98 PINK - OWNER GOLD - ASSESSOR
a)
'i
City of Edmonds STREET FILE
Critical Area Notice of Decision
Applicant:
Property Owner:
6dM--*'NJ.S SJMCO� cKs*r-w
Critical Area File #:
Permit Number:
BL-!Dl
Site Location:
Parcel Number:
21901 10C." Ave -Ad
1
1 005SY6000000aw
Project Description:
Now
% - 11.3
Conditional Waiver. No critical area report is required for the project described above.
I . There will be no alteration of a Critical Area or its required buffer. - ',!, 0as;de- cX-
4%e- (V-*%f%Ir^&�rI'% r"-.-eJ
2. The proposal is an allowed activity pursuant to ECDC 23.40.220, 23.50.220, and/or
23.80.040.
3. The proposal is exempt pursuant to ECDC 23.40.230. Arc%-.
Erosion Hazard. Project is within erosion hazard area. Applicant must prepare an erosion and
sediment control plan in compliance with ECDC 18.30. *0 �'%Spex-* J;--
Critical Area Report Required. The proposed project is witEin A critical arsea and/or a critical area
buffer and a, critical area report is required. A critical area report has been submitted and evaluated
for compliance with the following criteria pursuant to ECDC 23.40.160:
I The proposal minimizes the impact on critical areas in. accordance with ECDC 23.40.120,
Mitigation sequencing;
2. The proposal does not pose an unreasonable threat to the public health, safety, or welfare
on or off the development proposal site;
3. The proposal is consistent with the general purposes of this title and the public interest;
4. Any alterations permitted to the critical area are mitigated in accordance with ECDC
23.40.110, Mitigation requirements.
5. The proposal protects the critical area functions and values consistent with the best
available science and results in no net loss of critical functions and values; and
6. The proposal is consistent with other applicable regulations and standards.
Unfavorable Critical Area Decision. The proposed project is not exempt or does not adequately
mitigate its impacts on critical areas and/or does not comply with the criteria in ECDC 23.40.160 and
the provisions of the City of Edmonds critical area regulations. See attached findings of
noncompliance.
Favorable Critical Area Decision. The proposed project as described aboveand as shown on the
attached site plan meets or is exempt from the criteria in ECDC 23.40.160, Review Criteria, and
complies With the applicable provisions of the City of Edmonds critical area regulations. Any
subsequent changes to the proposal shall void this decision pending re -review of the proposal.
Conditions. Critical Area specific condition(s) have been applied to the permit number referenced
above. See referenced permit number for specific condition(s).
Reviewer ,, �ignatuPe��� Date"
Appeals: Any decision to approve, condition, or deny a development proposal or other activity based on the
requirements of critical area regulations may be appealed according to, and as part of, the appeal procedure, if any,
for the permit or approval involved.
Revised 1211612010
lb.
EX D
0 A ME
EXISTIN TOIL mi
9-T VIL DI r
HEIGHT _CALCUON A,, G-�
LATI
OF.
EXISTING GRA 287 .0' AT ALL FOUR CORNERS
PROPOSED GRADE: 2870' AT ALL FOUR CORNERS
FIN FLR ELEV 288 0'
f.,�A MmilaOlvIttivi HEIGHT OF
BUIUDIN:GABOVE GRADE : 13' =3-1/4'
MAX ALLOWED HEIGHT: 25' (3w)
PORTABLES AFl- =FACTORY BMT AND
LABELED WITH L83 APPROVAL
P E jM
ORTAME OCCUPANT LOAD Is 47
NE
FOR EACH CLASSROOM' ONE EXIT IS
i EACH _
REQUIRED FROM EACH __M.
106TH A W
A......
Lj
--EXISTING SEWFRUN
E
T=
A "=LL
w. ....... ......
;j
-7
/%
T
X
771
..............
F_
7 1
7
PROJECT DATA
I
—T WL
22901 106TH AVE W
EDMONDS, WA 98020
OWNER:
EDMONDS SCHOOL DISTRICT
CAPITOL PROJECTS OFF1 CE
CONTACT. MATT FINCH 425-431 7167
20420 68th AVE W
LYNNWOOD, WA 98036
ARCH17CT:
BASSETTI ARCHITECTS
I
CONTACT. STEVE ZANG 206-340-9500
SCOPE OF WORK
WORK UNDER THIS CONTRACT INCLUDES. BUT IS
NOT LIMITED TO INSTALLATION OF ONE PORTABLE
CLASSROOM INCLUDING MECH AND ELECT. Apb f7le.(,
JURISDICTION
CITY OF EDMONDS
SEWER AND WATER-
CITY OF EDMONDS
FIRE
SNOHOMISH COUNTY
TAX/ PARCEL f
00554000006006
ZONING
RS-8
LOT AREA
13.64 ACRES
EXISTING
CONSTRUCTION TYPE
BUILDING AREA
V_B
8.522 SOFT
OCCUPANCY.
E
PROPOSED
CONSTRUCTION TYPE
V—B
OCCUPANCY
E
BUILDING AREA
925 SOFT
CODE
2012 IBC
SPRINKLERS
NO, PEP ISC 903.2.3
TOILETS
PER IBC 2902 3.2 EXISTlN.G FACILITIES
ATE
ARE LOr _D WIIHIN tUU
PORTABLE HEIGHT IS MAX 14' ABOVE GRADE
UBC 2012 ALLOWABLE AREA=9.500 + 2.375 FOR
TWO SIDES OPEN — 11,875 SOFT TOTAL ALLOWABLE
AREA 8.522 . 925 — 9,447 SOFT PROVIDED.
DRAWING INDEX
ADA SITE PLAN
C2.0 CIVIL SITE PLAN
A2 FLOOR PLAN AND ELEVATIONS
AE2 SECTION
A2.3 FOUNDATION PLAN
A2 .4 FRAMING PLANS
A2.5 RAMP SYSTEM
A2.6 HVAC FLOOR PLAN AND SECTION
El 0 ELECTRICAL SITE PLAN
By IpLAW246
lv"
VIGNTY-MAP
LEGAL DESCRIPTION cn
TRACTS 6.7 AND 8 RICHMOND BEACH GARDEN TRACTS >
w
ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 8 OF
PLATS, ON PAGE 54, RECORDS OF SNOHOMISH COUNTY,
WASHINGTON
LLI
0
ENGINECR-NG DIVISIO14
AM
�IT!���LAN
LLI
13-
blSt Ptefffl
71 CkfA S"K Sh Soo
Se.ft.Wa9*vwn98Io4
T (M6) UO 95DO F (M) 340 9519
CrA ENGINEER
AHBL
TIMM=
CTRIM ENGINEER
GIS ENGWEERS
A
APPROIED
SH ER W 0 0 D
ELEMENTARY
SCHOOL
RELOCATABLE
CLASSROOMS
r0liTy COPY
JOB NO: 1493T00
ISSUE DATE: 615115
RESUB
MAY 0 12015
SITE
- ----- -----PLAN
An 4
F;V
1L
ADAPTOR SKIRT
4811
........ .... ....
GEOTEXTILE
FABRIC
RETRIEVAL STRAP
3611
OVERFLOW (TO
BYPASS PEAK
STORM VOLUMES)
2411
EXISTING
CATCH BASIN
SEDIMENT ACCUMULATION
NOTE:
1. FILTERS SHALL BE INSPECTED AFTER EACH STORM EVENT AND
CLEANED OR REPLACED WHEN 1/3 FULL.
2. PROVIDE CATCH BASIN SEDIMENT PROTECTION WITH
STREAIVIGUARD BASIN INSERT #3003, FROM FOSS
ENVIRONMENTAL 7440 W. MARGINAL WAY S. SEATTLE, WA
98108-4141 PHONE: 1-800-909-3677
NOT TO SCALE
Know what's below.
Call before you dig.
40�1
L
Line Type Area (square feet)
1. Non -Regulated
IL
NOT TO SCALE (PER DOE SWMMWn)
GRAPHIC SCALE
0 5 10 20
1" = 10 FEET
L
1=11 lzlz *3
INLET SEDIMENT
PROTECTION
EXISTING TREE
TO BE DEMOLISHED
44
,
1 ALL NOTES FROM THE CITY OF EDMONDS STANDARD PLANS SHALL APPLY TO THIS PROJECT.
2. CONSTRUCTION EQUIPMENT, STOCKPILES OR STRUCTURES SHALL NOT BLOCK EXISTING FIRE LANES. KEEP THE FIRE LANE CLEAR IN
CASE OF EMERGENCIES, AND VERIFY THE FIRE LANE LIMITS PRIOR TO CONSTRUCTION1
3. VERIFY ALL UTILITY LOCATIONS AND DEPTHS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE OWNER AND ENGINEER
OF ANY UTILITIES NOT SHOWN ON THE PLANS WITHIN OR ADJACENT TO THE LIMITS OF'NORK PRIOR TO CONSTRUCTION.
4. ALL SURFACE AND BELOW GRADE IMPROVEMENTS WITHIN THE LIMIT OF WORK SHALL BE PROTECTED UNLESS OTHERWISE NOTED.
5. ANY DAMAGE TO IMPROVEMENTS INTENDED TO REMAIN ARE TO BE FULLY REPAIRED CONTRACTOR'S EXPENSE.
6. REFER TO ELECTRICAL SITE PLAN TRENCHING DETAILS FOR WORK TO INSTALL ELECTRICAL CONDUIT & VAULTS.
7. SUBMIT MATERIAL SUBMITTALS FOR TESC, EARTHWORK, STORM DRAINAGE, AND SURFACING IN ACCORDANCE WITH ARCHITECT'S
SUBMITTAL PROCEDURES.
PORTAB"LE CLASSROOM F00"'LACEMEN'T 'NOTES:
1. VERIFY PORTABLE LOCATION PER THE ARCHITECTURAL PLAN. PRIOR TO THE ARRIVAL�OF PORTABLE CLASSROOMS, STAKE (OR
OTHERWISE PHYSICALLY LOCATE) ALL CORNERS OF EACH PORTABLE PER THE ARCHITECTURAL PLAN. THE ARCHITECT WILL VISUALLY
REVIEW THE LOCATION OF THE PORTABLES. NOTIFY THE ARCHITECT A MINIMUM OF 24 HOURS PRIOR TO PLACEMENT TO ALLOW FOR
VISUAL REVIEW.
2. SEE ELECTRICAL PLANS FOR TRENCHING & ELECTRICAL REQUIREMENTS.
PRESERVE EXISTING STORM DRAIN.
PRESERVE EXISTING POWER.
PLACE PORTABLE AND ASSOCIATED LANDINGS, STAIRS, AND RAMP ON
EXISTING ASPHALT.
PROVIDE SPLASHBLOCK AT DOWNSPOUT PER DETAIL THIS SHEET.
DEMOLISH EXISTING ABANDONED DRINKING FOUNTAIN.
X
Y
J�
7 1 - - - - - -
CL:
W
A IR
a -
'A
a-
N 0
D
j RA D NE
D
i t
R N I P 1 i�\ T E
L 1
I \1 �j �1
UU1 N
L
It
2
L-L
0%
2
P 0 W F-E R\
It
BINFT
B U A
RN 2 8 �;xb` C!
F
R A
81,
0 W'
QD
0 NC
A
-1 W/o c
p
------- ---- -------
4
k
IL-4-1
ENGINEERING DIVISION
P ROV D A NOTEP
ate:414-5
Lij
C/)
75
W
LU
a-
71 Columbia Street, Suite 500
Seattle, Washington 98104
T (206) 340 9500 F (206) 340 9519
CIVIL ENGINEER
AHBL
1200 Sixth Ave, Suite 1620
Seattle, WA 98101
T (206) 267 2425
ELECTRICAL ENGINEER
HARGIS ENGINEERS
1201 Third Ave N, Suite 600
Seattle, WA 98101
T (206) 436 0457
T A C 0 M A - SEATTLE - SPOKANE - TRI-CITIES
1200 6th Avenue, Suite 1620 Seaftle,WA98101
206.267.2425TEL 206.267.2429FAX wwahbl.comWEB
REVISIONS DATE
C>-5, 0 ,
EDMONDS SCHOOL DISTRICT #15
SHERWOOD
ELEMENTARY
SCHOOL
JOB NO: 14937.00
ISSUE DATE: 03/09/15
CIVIL SITE
=0'al, Li I
`C*2EG
2�zlol 1) 1 1 D olk Avs� W
BL.D'ZO15— 03-7L�
HEIGHT CALCULATION n-a _k "&I
0e;1--ti Cfc- Z�tsv
EXISTING GRADE: 287.0' AT ALL FOUR CORNERS
PROPOSED GRADE: 287.0' AT ALL FOUR CORNERS
FIN FLR ELEV 288.0
M#�� HEIGHT OF
BUILDING ABOVE GRADE: 13' 3-1/4 S 00 - 2-14j
MAX ALLOWED HEIGHT: 25' ( 3x-11)
PORTABLES ARE FACTORY BUILT AND
LABELED WITH L&I APPROVAL
PORTABLE OCCUPANT LOAD IS 47
FOR EACH CLASSROOM. ONE EXIT IS
REQUIRED FROM EACH CLASSROOM.
SITE PLAN 0 10, 20'
I M OEM
SCALE: 1"=20'-O" SITE PLAN.dwgM c
PROJECT DATA
PROJECT SHERWOOD ELEMENTARY SCHOOL
22901 106TH AVE W
EDMONDS, WA 98020
OAER: EDMONDS SCHOOL DISTRICT
CAPITOL PROJECTS OFFICE
CONTACT; MATT FINCH 425-4,31 7167
20420 68th AVE W
LYNNWOOD, WA 98036
ARCHITECT: BASSETTI ARCHITECTS
CONTACT; STEVE ZANG 206-340-9500
SCOPE OF kRK: WORK UNDER THIS CONTRACT INCLUDES BUTIS
NOT LIMITED TO INSTALLATION OF ONE PORTABLE
CLASSROOM INCLUDING MECH AND ELECT. AmD Vit-5 AtowtM,
JURISDICTION: CITY OF EDMONDS
SEWER AND WATER: CITY OF EDMONDS
FIRE: SNOHOMISH COUNTY
TAX/ PARCEL # 00554000006006
ZONING: RS-8
Coe's
LOT AREA: 13.64 ACRES
V NO
VII
(j
eX
EXISTING
ip't. - .
CONSTRUCTION TYPE: V—B
ro
BUILDING AREA: 8,522 SQFT
X
OCCUPXNCY: E
PROPOSED
CIO
CONSTRUCTION TYPE: V—B
OCCUPANCY: E
BUILDING AREA: 925 SQFT
CODE: 2012 IBC
SPRINKLERS: NO, PER IBC 903.2.3
TOILETS: PER IBC 2902.3.2 EXISTING FACILITIES
ARE. LOCATED WITHIN 500
PORTABLE HEIGHT IS MAX 14' ABOVE GRADE
UBC 2012 ALLOWABLE AREA=9,500 + 2,375 FOR'
TWO SIDES OPEN = 11,875 SQFT TOTAL ALLOWABLE
AREA. 8,522 + 925 = 9,447 SQFT PROVIDED.
I UMM I �M
AO.1
SITE PLAN
C2.0
CIVIL SITE PLAN
A2.1
FLOOR PLAN AND. ELEVATIONS
A2.2
SECTION
A2.3
FOUNDATION -PLAN
A2.4
FRAMING PLANS
A 2. 5)
RAMP SYSTEM
A2.6
HVAC FLOOR PLAN AND SECTION
E1.0 ELECTRICAL SITE PLAN
41( vo%ml�
Ts
UJI
LEGAL DESCRIPTION U)
>
TRACTS 6,7 AND 8 RICHMOND BEACH GARDEN.TRACTS UJI
ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 8 OF
PLATS, ON PAGE 54, RECORDS OF SNOHOMISH COUNTY,
WASHINGTON
LU
ENGINEERING
APE) E A N
'0
Date.Zg
40' 75
r7l\ N
UJI
71 Columbia Street, Suite 500
Seattle, Washington 98104
T (206) 340 9500 F (206) 340 9519
CIVIL ENGINEER
AHBL
1200 Sixth Ave, Suite 1620
Seattle, WA 98101
T (206) 267 2425
ELECTRICAL ENGINEER
HARGIS ENGINEERS
1201 Third Ave N, Suite 600
Seattle, WA 98101
T (206) 436 0457
7101 � REGSTERED
ARCH TECT
RCHARYL HLO
'ATE CF MSH
A
A
A
A
A
A
REVISIONS DATE
EDMONDS SCHOOL DISTRICT #15
SHERWOOD
ELEMENTAR Y
SCHOOL
.RELOCATABLE
CLASSROORKWANS
REET FILE
JOB NO: 14937.00
ISSUE DATE: 5/5/15
RESUB
MAY 0 12015
BUILDING DEPAR,:7MENT
ci-ry OF EDMONDS
SITE..
PLAN
Zone
Satbacks
L, F Ci
IWI
Front (N/w
Sides(10)
Rea.-
AO.1
F
LEGEND:
L
�/ Ai
N\1
L
10
7
10
C6
11�b
All
i 0
10
j\
N�
0�1
ADAPTOR SKIRT
48"
GEOTEXTILE
FABRIC
Sj 0 N S Z`
POV
"A'
�j E
F
X
0 . . . . . .
4
1D
IE= 281.70±
CONNECT PVC PIPE TO\
EXISTING CO�CRETE
4 PIPE WITH FE
,�RNCO
RETRIEVAL STRAP
36
OVERFLOW (TO
BYPASS PEAK
STORM VOLUMES)
2411
EXISTING
CATCH BASIN
SEDIMENT ACCUMULATION
NOTE:
1 . FILTERS SHALL BE INSPECTED AFTER EACH STORM EVENT AND
CLEANED OR REPLACED WHEN 1/3 FULL.
2. PROVIDE CATCH BASIN SEDIMENT PROTECTION WITH
STREAMGUARD BASIN INSERT #3003, FROM FOSS
ENVIRONMENTAL 7440 W. MARGINAL WAY S. SEATTLE, WA
98108-4141 PHONE: 1-800-909-3677
NOTTO SCALE
MIN
0 ta"'I
ROOF DOWNSPOUT PER BUILDING
MANUFACTURER'S DETAILS
PROVIDE REDUCER BUSHING SO DOWNSPOUT FITS
SNUGLY TO ROOF DRAIN.
CLEANOUT WITHIN FINISHED
2'OF BUILDING
GRADE 211 MIN. -
6" MIN.
6" PVC SDR 35
TYP.
12" MINIMUM
PROVIDE FITTINGS AS
REQUIRED
B'NDONE
1 1 �1\1 (' ',A/
W1 - I I q �j V, 1� A-\ T E R
DPINK.
'IN
U N A
NOT TO SCALE
SAWCUT
PAVEMENT
EXISTING
ASPHALTIC
SURFACING
I i IV; ui,�.
N
_G
SUBGRADE
COMPACTED TO 95%
NOT TO SCALE
PORTABLE PER
MANUFACTURER
NOTES:
1. COORDINATE DOWNSPOUT LOCATIONS WITH
BUILDING CONTRACTOR. NO OFFSETS ALLOWED.
2. PROVIDE CLEANOUT AT ALL DOWNSPOUT
CONNECTIONS. SEE BUILDING MANUFACTURE'S
PLANS FOR LOCATION AND NUMBER OF
DOWNSPOUTS.
POWER
rl
�BINE
/1 11
9
I I 1! 1 5 1
IE= 81.43±
CONNECTPVC PET
EXISTING CO RETE i
PIPE WITH FERNCO
DS
2
7
I �LT
A
L
2�11 -
T
3" MIN. OR MATCH EXISTING
IF GREATER, HMA CLASS Y2"
WSDOT SPEC 5-04.2.
6" OR MATCH EXISTING IF GREATER,
CRUSHED SURFACING TOP COURSE,
WSDOT SPEC.. 9-03.9(3).
HOT TAR SEAL
JOINT TYPICAL
TACK COAT VERTICAL
EDGES OF EXISTING
PAVEMENT
DRILL AND TAP (SPLITTING
THE SEAM) SET MADE BOL'
DOWN WITH 3/8" SS ALLEN-
HEAD BOLTS - 2 PLACES
1/8" RAISE - 1/2"
WIDE BORDER
M-M-02M
INLET SEDIMENT
PROTECTION
STORM LINE
CLEANOUT
DOWNSPOUT
ASPHALT PATCH
1. ALL NOTES FROM THE CITY OF EDMONDS STANDARD PLANS SHALL APPLY TO THIS PROJECT.
2. CONSTRUCTION EQUIPMENT, STOCKPILES OR STRUCTURES SHALL NOT BLOCK EXISTING FIRE LANES. KEEP THE FIRE LANE CLEAR IN
CASE OF EMERGENCIES, AND VERIFY THE FIRE LANE LIMITS PRIOR TO CONSTRUCTION.
3. VERIFY ALL UTILITY LOCATIONS AND DEPTHS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE OWNER AND ENGINEER
OF ANY UTILITIES NOT SHOWN ON THE PLANS WITHIN OR ADJACENT TO THE LIMITS OF WORK PRIOR TO CONSTRUCTION.
4. ALL SURFACE AND BELOW GRADE IMPROVEMENTS WITHIN THE LIMIT OF WORK SHALL BE PROTECTED UNLESS OTHERWISE NOTED.
5. ANY DAMAGE TO IMPROVEMENTS INTENDED TO REMAIN ARE TO BE FULLY REPAIRED AT CONTRACTORS EXPENSE.
6. REFER TO ELECTRICAL SITE PLAN TRENCHING DETAILS FOR WORK TO INSTALL ELECTRICAL CONDUIT & VAULTS.
7. SUBMIT MATERIAL SUBMITTALS FOR TESC, EARTHWORK, STORM DRAINAGE, AND SURFACING IN ACCORDANCE WITH ARCHITECTS
SUBMITTAL PROCEDURES.
8. PLUGGING EXISTING PIPE: WHERE SHOWN ON THE PLANS, EXISTING PIPES SHALL BE PLUGGED FOR A DISTANCE OF 2 TIMES THE
DIAMETER WITH COMMERCIAL CONCRETE. C
ARE�, SHALL BE USED IN PLACING THE CONCRETE IN THE PIPE TO SEE THAT THE OPENING OF
COMPLETELY FILLED AND THOROUGHLY PLUGGED.
THE PIPE IS
9. ABANDON IN PLACE EXISTING PIPE: WHERE PIPES ARE TO BE ABANDONED IN PLACE, PLUG OPEN ENDS OF ABANDONED UNDERGROUND
PIPING, PER ABOVE, AND FILL ABANDONED PIPE WITH CDF.
PORTABLE CLASSmOOM PLACEMENT NOTES:
1. VERIFY PORTABLE LOCATION PER THE ARCHITECTURAL PLAN. PRIOR TO THE ARRIVAL OF PORTABLE CLASSROOMS, STAKE (OR
OTHERWISE PHYSICALLY LOCATE) ALL CORNERS� OF EACH PORTABLE PER THE ARCHITECTURAL PLAN. THE ARCHITECT WILL VISUALLY
REVIEW THE LOCATION OF THE PORTABLES. NOTIFY THE ARCHITECT A MINIMUM OF 24 HOURS PRIOR TO PLACEMENT TO ALLOW FOR
VISUAL REVIEW.
D - D
2. SEE ELECTRICAL PLANS FOR TRENCHING & ELECTRICAL REQUIREMENTS.
KEYNOTES:
PRESERVE EXISTING STORM DRAIN.
PRESERVE EXISTING POWER.
PLACE PORTABLE AND ASSOCIATED LANDINGS, STAIRS, AND RAMP ON EXISTING
ASPHALT.
7
CAP AND ABANDON STORM LINE IN PLACE PER GENERAL NOTES 8 AND 9.
31
PROVIDE NEAT SAW CUT AND REMOVE EXISTING ASPHALT. REPLACE ASPHALT PER
FP, <S
REPLACE LANDSCAPE TO EXISTING CONDITION.
(D
SEE ELECTRICAL PLANS FOR TRENCHING DETAILS.
PRESERVE EXISTING WATER.
ALL STORM PIPE TO BE 6" PVC AND INSTALLED AT A MINIMUM SLOPE OF 0.5%.
REMOVE DEBRIS FROM ASPHALT SURFACING AND PROVIDE 3" DEEP SWALE 1 FOOT
WEST OF THE EDGE OF ASPHALT TO COLLECT RUNOFF FROM ASPHALT.
CONTRACTOR TO PROVIDE TV INSPECTION OF EXISTING LINE FROM BUILDING TO
8 MAINLINE CONNECTION. SUBMIT DOCUMENTATION FOR ALL APPROXIMATE INVERT
ELEVATIONS, AND STUB OUT CONNECTION LOCATIONS.
SEE ARCHITECTURAL PLAN FOR RELOCATION OF BIKE RACK.
PRESERVE AND PROTECT EXISTING TABLES.
RIGID FLEXIBLE go-
(D.I., CONC.) (CPEP, CMP, PVC) PRESERVE AND PROTECT EXISTING GREEN HOUSE.
SUBGRADE ELEVATION
DETECTABLE WARNING TAPE
TRENCH BACKFILL FOR ONSITE UTILITIES 12" BELOW FINISH GRADE
SHALL BE IMPORTED STRUCTURAL FILL.
PIPE AS NOTES:
WITHIN RIGHT-OF-WAY TRENCH BACKFILL SPECIFIED ON 1. BACKFILL MATERIAL SHALL NOT HAVE
SHALL BE CRUSHED SURFACING TOP PLANS PARTICLE SIZE GREATER THAN V WITHIN
COURSE, WSDOT 9-03.9(3) 95% COMPACTION,_ 6" OF THE PIPE OR THE CONTRACTORHAS
6" MAXIMUM LIFTS.
THE OPTION TO USE GRAVEL BACKFILL
PIPE ZONE BEDDING.
2. PROVIDE DETECTABLE LOCATION TAPE
CONTINUOUSLY INSCRIBED WITH
DESCRIPTION OF UTILITY WITH METAL
Ci
X CORE AND COLORED (GREEN FOR STORM,
LQ
RED FOR ELECTRICAL AND ORANGE FOR
4"MIN. PHONE)
11 E�i I 1EIT-11 '.1117111 GRAVEL BACKFILL FOR
PIPE ZONE BEDDING
I.D. + PER WSDOT 9-03.12(3),
95% COMPACTION
TK`k ENC H rE $`A C K F I L L Alk, M' D E D D 1 G
3 NOT TO SCALE C�,VNER/CONTRACTOR 1S RESPONSIBL�
C
FOR EROSION CONTROL AND DAMAGE m Rr-D
NOTES:
1. PIPE MATERIAL PER PLAN. APPMOVED ASNOTEG
LETTERING 2. PIPE DIAMETER PER PLAN. MENGI �PING
3. ABS TO PVC USE PVC ADAPTOR OR FERNCO WITH STAINLESS
"STORM" = STORM DRAIN
"SEWER" = SEWER DRAIN STEEL CLAMPS OR APPROVED EQUAL.
4. PVC TO CAST IRON OR CONCRETE USE FERNCO NTH Date:
STAINLESS STEEL CLAMPS OR APPROVED EQUAL. APPROVED
5. CLEANOUT PIPE AND FITTINGS SHALL BE PVC FOR SEWER, FIRE DEPARTMENT
WITH GASKET FITTINGS, NO GLUE JOINTS ALLOWED. jA4]2i�9\40W
5jkjzrft4E:-
1011
911
5/8
F
4"
711 ------
3/411:1
-8-3/4
- 15"
CAST IRON RING AND LOCKING COVER
OL I
EAN UT
5 NOT TO SCALE
3000 psi CLASS C 21-011-1
CONCRETE (TYP)
4.
4-3/4"
12" 0
FIBRE JOINT
PACKING
'(1/8) 11 L
45
BEND
PROVIDE
WATER TIGHT
PLUG
Line.
Type
Area (square feet)
Non -Regulated
........ . . .
. ........ ..... ..... . .
.. ..... . ..
. . . . . ..... ....... .
Exempt
Regulated
2.
Replaced
� "�,t � : - .'';"�,�pl
0
_io
�n - ;, �
3.
New (Post 1977)
i +
ig
1, zz I
Total Regulated Impervious Area
4.
Mirigation required if bi excess of 2000sf
5.
Total Area Mitigated by Existing Stormwater Management Systeni(s)
0
6.
Regulated Area Not: Yet Mitigated
0
7.
Area Proposed to be Mitigated by Low Impact Development Techniques
0
8.
Area Proposed to be Mitigated through Conventional SWM Techniques
0
Ljj
U)
F_
Uj
71 Columbia Street, Suite 500
Seattle, Washington 98104
T (206) 340 9500 F (206) 340 9519
CIVIL ENGINEER
AHBL
1200 Sixth Ave, Suite 1620
Seattle, WA 98101
T (206) 267 2425
ELECTRICAL ENGINEER
HARGIS ENGINEERS
1201 Third Ave N, Suite 600
Seattle, WA 98101
T (206) 436 0457
ARCH ITECTS S'FANAIP
EDMONDS SCHOOL DISTRICT #15
SHERWOOD
E L E IRVI E N T A R \T/
SCHOOL
RELOCATABLE
CLASSROOMS
22901 106TH AVENUE W
EDMONDS, WA 98020
JOB NO: 15970.00
ISSUE DATE: 2/19/2016
CIVILSITE
PLAN
14AR 17 201119-
Lj -
CT11.
C1.0
PORTABLE; V-B NS CONSTRUCTION
IBC 2015 ALLOWED AREA 9,500 SF
OPEN ON TWO SIDES = 9,500 X 1.23 = 11,685
10,370 SF PROVIDED
I = (F/P-.25) W/30
P=418
F=203
W=30
0,
---------------------
SITE PLAN
GENERAL NOTES
1 PORTABLE CONSTRUCTION TO BE PER APPROVED SHOP DRAWINGS BY
MANUFACTURER AND MAY DIFFER FROM BID DOCUMENTS.
2. PORTABLES ARE FACTORY BUILT AND LABELED WITH L&I APPROVAL.
3. PORTABLE OCCUPANT LOAD IS q ( MAXIMUM FOR EACH CLASSROOM. ONE
EXIT ISREQUIRED FROM EACH CLASSROOM.
4. EDMONDS ZONING ALLOWS: ROOF EAVE PROJECTIONS LESS THAN 2'AND
DECKS LESS THAN THIGH TO PROJECT INTO SETBACKS.
HEIGHT CALCULATION
EXISTING GRADE:
PROPOSED GRADE:
FIN FLR ELEV
MAXIMUM HEIGHT OF
BUILDING ABOVE GRADE:
MAX ALLOWED HEIGHT:
287.0'AT ALL FOUR CORNERS
287.0'AT ALL FOUR CORNERS
288.0'
13'3-1/4"
25'
U
n
0 10, 20' 40'
SITE PLAN.dwg I M MM
V I "*Qoff�
PROJECT SHERWOOD ELEMENTARY SCHOOL
22901 106TH AVE W
EDMONDS, WA 98020
OWNER: EDMONDS SCHOOL DISTRICT
CAPITOL PROJECTS OFFICE
20420 68th AVE W.
LYNNWOOD, WA 98036
ARCHITECT:
SCOPE OF WORK:
JURISDICTION:
SEWER AND WATER:
FIRE:
TAX/ PARCEL #'
ZONING:
LOT AREA:
CONSTRUCTION TYPE:
BASSETTI ARCHITECTS
CONTACT STEVE ZANG, 206-340-9500
WORK UNDER THIS CONTRACT INCLUDES, BUT IS NOT
LIMITED TO INSTALLATION OF TWO PORTABLE
CLASSROOMS INCLUDING. MECHANICAL AND ELECTRICAL.
CITY OF EDMONDS
CITY OF EDMONDS
SNOHOMISH COUNTY
00554000006006
RS-8
13.64 ACRES
9--i
OCCUPANCY: E
PROPOSED
CONSTRUCTION TYPE:
OCCUPANCY:
BUILDING AREA:
CODE:
SPRINKLERS:
V-13
E
1,848 SF
2012 IBC
NO, PER IBC 903.2.3
PORTABLE HEIGHT IS MAX 14'ABOVE GRADE
VICINITY MAP
DIn A
rXMWIN"'G INDEX-
i AO.1 SITE PLAN 5&t a?
'PeT - t
C1.0 CIVIL SITE PLAN
��j Ot the
scope ea
tvs cy� -
A2.1 FLOOR PLANS 'aer Va, e
��Tc 'j Z01 t tll
j 10
A2.2 FOUNDATION PLAN
A3.1 ELEVATIONS vev sv'Y
t"o Coll,
0'r eQ
A3.2 SECTION c�
A5.1 DETAILS ac" ti�e31'
ixwa� 0"'�0�6 ,
A5.2 RAMP SYSTEM
M2.1 HVAC FLOOR PLAN & SECTIONS
EO.1 ELECTRICAL LEGEND AND ABBREVIATIONS
E1.0 ELECTRICAL SITE PLAN
E3.0 PORTABLE POWER AND SYSTEMS PLANS
E4.0 SYSTEMS DETAILS
E4.1 SYSTEMS DETAILS
E4.2 SYSTEMS DETAILS
E5.0 ONE LINE DIAGRAM AND PANEL SCHEDULES
L_
APPRO 1)
FIR DEPAKFNIEN'r
LEGAL DESCRIPTION
TRACTS 6,7 AND 8 RICHMOND BEACH GARDEN TRACTS ACCORDING
TO THE PLAT THEREOF RECORDED IN VOLUME 8 OF PLATS, ON PAGE
54, RECORDS OF SNOHOMISH COUNTY, WASHINGTON
x(p
All.
Zone Comer / Flag
&LbLc_ks R Wred
Front \d/A/
Sides.s/9-
Near-
Other ---------
APPMOVEDAS NOTED
BY ��IN� E R I N G
Date:
sz'e'
F_
Uj
75
Orf
Uj
a-
71 Columbia Street, Suite 500
Seattle, Washington 98104
T (206) 340 9500 F (206) 340 9519
CIVIL ENGINEER
AHBL
1200 Sixth Ave, Suite 1620
Seattle, WA 98101
T (206) 267 2425
ELECTRICAL ENGINEER
HARGIS ENGINEERS
1201 Third Ave N, Suite 600
Seattle, WA 98101
T (206) 436 0457
A
A
A
A
A
A
REVISIONS DATE
EDMONDS SCHOOL DISTRICT #15
SHERWOOD
ELEMENTARY
I
SCHOOL
RELOCATABLE
CLASSROOMS
22901 106TH AVENUE W
I EDMONDS, WA 98020
JOB NO: 15970.00
ISSUE DATE: 2/19/2016
SITE
PLAN
I-4AR, 17 2 j"i3i
SCALE: I"=20'-O"
�r
PROJECT DIRECTORY
COMPANVROLE
ADDRESS
PHONE
CONTACT/EMAIL
EDMONDS SCHOOL DISTRICT
20420 68TH AVE W
(425) 431-7161
NICK CHOU
— OWNER
LYNNWOOD, WA 98036
choun@edmonds.wednet.edu
KPFF CONSULTING ENGINEERS
1601 5TH AVE
(206) 622-5822
THADDEUS EGGING
— PRIME CONSULTANT
SUITE 1600
thaddeus.egging@kpff.com
— CIVIL ENGINEER
SEATTLE, WA 98101
1
SHEET INDEX
SHT NO DWG TITLE
GO.01
COVER SHEET
GO.02
j
LEGEND, ABBREVIATIONS, AND GENERAL NOTES
SVO.01
SURVEY
SVO.02
SURVEY
SVO.03
SURVEY
SVO.04
SURVEY
CO.01
MASTER SITE PLAN
CO.02
FIRE APPARATUS AND SHUTTLE ACCESS PLAN
C1.01
TESC PLAN
C1.02
TESC DETAILS
C2.01
DEMOL111ON PLAN
C3.01
GRADING, DRAINAGE, AND UTILITY PLAN
C3.02
GRADING AND DRAINAGE DETAILS
C3.03
GRADING AND DRAINAGE ENLARGEMENTS AND DETAILS
C3.04
SECTIONS
C4.01
PAVING PLAN
C4.02
PAVING DETAILS
C4.03
PAVING DETAILS
C4.104
ADDITIVE ALTERNATIVE —GRIND AND OVERLAY
C4.05
ADDITIVE ALTERNAlIVE—GRIND AND OVERLAY DETAILS
C5.01
STRIPING AND SIGNIAGE PLAN
C5.02
STRIPING AND SIGNAGE DETAILS
C6.01
HORIZONTAL CONTROL TABLES
C7.01
CITY OF EDMONDS DETAILS
C7.02
CITY OF EDMONDS DETAILS
L1.01
LANDSCAPE PLAN
L1.02
LANDSCAPE DETAILS
L2.01
IRRIGA11ON PLAN
IL1.01
ILLUMINATION PLAN
I UTILITY PURVEYORS I
ELECTRICITY- SNOHOMISH COUNTY PUD 877-783-1000
WATER: OLYMPIC VIEW WATER SERVICE 425-771-0220
STORM DRAIN: CITY OF EDMONDS 425-771-0220
SANITARY SEWER: OLYMPIC MEW SEWER SERVICE 425-771-0220
GAS: PUGET SOUND ENERGY 888-225-5773
RIGHT-OF-WAY WORK
LENGTH OF WORK IN RIGHT—OF—WAY
127 LF
NUMBER OF DAYS TO COMPLETE RIGHT—OF—WAY WORK
TBD
AN11CIPATED RIGHT—OF—WAY START DATE
1 JULY 2015*
AN11CIPATED RIGHT—OF—WAY FINISH DATE
30 AUG 2015*
ROW WORK WILI OCCUR WITHIN THIS TIMEFRAME, EXACT LENGTH OF WORK
IS TO BE DETERMINED. IT IS AN11CIPATED TO BE MUCH SHORTER (15
DAYS±)
APPROXIMATE EARTHWORK QUANTITIES
TYPE
VOLUME (CY)
EXCAVATION (EXPORT)
870
FILL (IMPORT)
NOTE: EARTHWORK VOLUMES ARE APPROXIMATE AND SHOWN FOR PERMITTING
PURPOSES ONLY. THESE ESTIMATES SHALL NOTE BE USED FOR BIDDING
PURPOSES
TREE REMOVAL AND REPLACEMENT
DESCRIPTION
NUMBER
COMMENTS
TREES TO BE REMOVED
9 TOTAL
REMOVED FOR CONSTRUCTION
SIGNIFICANT TREES
9 TOTAL
.REPLACED TREES 13�
TOTAL
AREA OF DISTURBANCE SUMMARY
TYPE
IMPERVIOUS (SF)
PERVIOUS (SF)
TOTALS (SF)
EXISTING SITE
19,714
23,537
43,251
DEVELOPED SITE
29,886
13,365
43,251
.ADDED AREA
10,172
(10,172)
NOTES:
1. THESE AREAS ONLY REPRESENT AREAS DISTURBED BY CONSTRUCTION
ACTIVITIES. UNDISTURBED AREAS WITHIN THE APPROXIMATE LIMITS OF
WORK ARE NOT INCLUDED.
2. PAVEMENT AREAS ARE APPROXIMATE AND SHOWN FOR PERMITTING
PURPOSES ONLY. THESE ES11MATES SHALL NOT BE USED FOR BIDDING
PURPOSES.
wMamm
'***A PnMnMn'q
SHERWOOD ELEMENTARY
PROJECT LOCATION
�Uli
_j
STREET SW
A
APPROXIMATE LIM ITS OF WORK
229TH PLACE SW
�Lu PROPERTY BOUNDRY
X
map L
c
L
231ST STREET SW----------
JCK ROUTE
NORTH
LOCATION MAP AND TRUCK ROUTE (]F-�
SCALE: 1 1,000'
DRAWN BY DESIGNED BY
KWP/TY AJS re
0 Call 81
CHECKED BY APPROVED BY
0 two business days 1601 5th Avenue, Suite 1600
TJE TJE before yo Seattle, WA 98101
DAfE 206.622.5822
05/27/2015 S C A L E: lq3ff www.kpff.com
REVISION JOE No. :114407 AS SHOWN
�3s
APPROV D
F1 E EPA
(V7
PARKING S * PACES.REUD
PARKING SPACES PROPOSto 44"
BARRIER FREE PARKING SPACES
Mg ----------- mr,
DATE: 7
`BLDG. OFFICIAL
PFERMOT INURRBaR
,4k (2CW-4z Th t7,0'04 19Q2MI-r feV--
nz4mc- CaTw4L Pw* 00(7, 113r,
't "fUiz "So _C0 DJzA1tJA6701 9ZPbXT 1Z4ft-T-0F'-W" 10e�ZWT
PRWPAF4F_b eq 14PFV I Z�+-reo MA'q 20IS- NORTH
Ob VICINITY MAP STREET FILE
tain Electrical Permit from
State Labor & Industries SCALE: 1" = 100'
EDMONDS
APPROVED FOR CONSTRUCTIONS SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS
CITY OF EDMONDS EDMONDS, WASHINGTON
DATE:
27 BY4!:�
IST
'10KAL
SCHGDL
DISTRICT
COVER SHEET
RESUM
juN o 12015
Q DEPARTMEN'r
WAILIOVINON EDMONDS
a
r19 aL�_
A I Nnf
Ob-Ai 0-011 LI-O?-'
SHEET
GO. 0 1
FOR PERMIT
CD
CD
w
V)
Q)
cn
E
ID
bi
_0
0
0
a)
V)
C,
0')
m
'q-
T
Uj
CD
(D
CD
C.)
E U=i
0 =
cn
LO
E3 E
CIJ
ABBREVIATIONS LEGEND (EXISTING) LEGEND (PROPOSED)
EXISTING PROPOSED - - - - - - SURVEYED TOP OFSLOPE C� FIRE HYDRANT (ELEVATION OF FLANGE) PROPERTY LINE EXTRUDED CURB PER COE STD E2.7
ASPH ASPHALT @ AT
C CALCULATED ADD ADDITIVE - - - - - - SURVEYED TOE OF SLOPE E0 WATER METER APPROXIMATE LIMIT OF WORK VER11CAL CURB PER COE STD E2.10
CONC - CONCRETE APPROX APPROXIMATE
D/W DRIVEWAY BC BOTTOM OF CURB --------------------------------------------- TOP OF DITCH WATER VAULT M H N FILTER FABRIC FENCE CURB WHEEL STOP
ELEV ELEVATION BLDG BUILDING
E/M ELECTRIC METER BM BENCH MARK CENTERLINE OF DITCH 14 IRRIGATION VALVE TEMPORARY CHAIN LINK CONSTRUCTION FENCE - - - - - - - - SAWCUT LINE
EXC EXTRUDED CURB BW BOTTOM OF WALL
F/H FIRE HYDRANT DRAINAGE FLOW LINE 6�
GVL GRAVEL CB CATCH BASIN UTILITY POLE W/LUMINAIRE (WOOD) CATCH BASIN PROTECTION CHAIN LINK FENCE
LOC LOCATE/LOCATION CFS CUBIC FEET PER SECOND BUILDING 0 UTILITY POLE (WOOD) TEMPORARY DRAINAGE SWALE FLOW LINE HANDRAIL
LP LIGHT POLE CL CENTER LINE
M/B MAILBOX CLR CLEAR - - - - - - - - - - - - ROOF LINE GUY ANCHOR SAND BAG CHECK DAM CURB RAMP TYPE
M MEASURED co CLEAN OUT x FENCE
OS OIL SEPARATOR COE CITY OF EDMONDS /'O\/ PARKING/AREA LIGHT (METAL) MOBILE 55 GALLON DRUM NTH PUMP ....................
..........................................
...............
P PLAT .......................... : 7. *.,.*.* 7
..........................
CONC CONCRETE & & ...... .. ASPHALT PAVEMENT
EDGE OF ASPHALT
PA. PARCEL NUMBER CY CUBIC YARD YARD LIGHT TEMPORARY SEDIMENT TANK
P/A PLANTER AREA/STRIP S ss- SANITARY SEWER 4
4
P/B PLANTER BOX (RAISED) DI DUCTILE IRON R ELECTRIC JUNCTION BOX CONCRETE SIDEWALK PER COE STD E2.13
RCG ROLLED CURB AND GUTTER DIA DIAMETER SD SD- STORM DRAIN
RET RETAINING DOE DEPARTMENT OF ECOLOGY M ELECTRIC METER FUTURE INFILTRA11ON AREA
W_ LAND CAPE AREAS
RRT RAILROAD TIE DS DOWNSPOUT W_ WATER
TFMR TRANSFORMER DIP DUCTILE IRON PIPE IM ELECTRIC SERVICE (OUTLET) ff DEMOLISH UTILITY LINE
TYP TYPICAL E EAST/EASTING G- G GAS Fil COMMUNICATIONS BOX (PROVIDER NOTED) FIRE HYDRANT ASSEMBLY
UGC UNDERGROUND COMMUNICATIONS EL/ELEV ELEVATION _0HP-0HP- x X DEMOLISH CHAINLINK FENCE GATE VALVE
UGP UNDERGROUND POWER OVERHEAD POWER GAS VALVE - - - - - - - - - -
UP UTILITY POLE EX/EXIST EXISTING SAWCUT LINE
VCB VERTICAL CURB FD FOOTING DRAIN _0HPT-0HPT- OVERHEAD POWER & COMMUNICA11ONS TEE
VCG VERTICAL CURB & GUTTER FT FOOT/FEET F21 GAS METER DEMOLISH CURB
W/V WATER VALVE GPM GALLONS PER MINUTE OHT- OHT- OVERHEAD COMMUNICATIONS UTILITY (UNKNOWN TYPE/PROVIDER) ........................... DEMOLISH PAINT STRIPE 4" SOLID PAINTED STRIPE
CLF CHAIN LINK FENCE IE INVERT El EVATION d- d- UNDERGROUND POWER Z-� ADA PARKING SIGN
HBF HORIZONTAL BOARD FENCE LF LINEAR FOOT 0 BOLLARD
VBF VERTICAL BOARD FENCE MAX MAXIMUM T T UNDERGROUND COMMUNICATIONS ?,q DEMOLISH TREE ADA PARKING SYMBOL
HRF HORIZONTAL RAIL FENCE 0-- FLAG POLE
A ALDER MIN MINIMUM CENTERLINE RIGHT-OF-WAY X DEMOLISH CATCH BASIN/ AREA DRAIN TRAFFIC DIRECTIONAL ARROW
B BIRCH N NORTH/NORTHING SIGN SALVAGE SIGN AND LIGHT POLE
C CEDAR N.T.S. NOT TO SCALE PUBLIC LAND SURVEY SYSTEM SUBDIVISION LINE STOP BAR
CLST SMALL TRUNK CLUSTER 0C ON CENTER m MAIL BOX 0 DEMOLISH BOLLARD/POST
CNF CONFIER (UNDETERMINED SPECIES) PERF PERFORATED ADJACENT BOUNDARY LINE ':...�7 7. �7. 7:': CROSSWALK BAR
DEC DECIDUOUS (UNDETERMINED SPECIES) TEST PIT DEMOLISH ASPHALT
P.O.C. POINT OF CONNECTION
F FIR BRUSH LINE
HDG HEDGE S SOUTH WETLAND FLAG NO PARKING" STRIPING
MULTIPLE LIKE TRUNK DIAMETERS SDCB STORM DRAIN CATCH BASIN KEYSTONE/BLOCK WALL (UNLESS NOTED) _MN DEMOLISH CONCRETE SIDEWALK -281 - EXISTING CONTOUR LINE
MULTIPLE DIFFERENT TRUNK DIAMETERS SD STORM DRAIN STORM DRAIN MANHOLE
#x#"
B/O BUSES ONLY SDCO STORM DRAIN CLEANOUT STORM DRAIN CATCH BASIN MCC? ROCKERY 7 7 7 7) _281- PROPOSED CONTOUR LINE
D/E DEAD END SF SQUARE FOOT .......... DEMOLISH PLAYGROUND AND PLAY STRUCTURES
STORM DRAIN CATCH BASIN W/SbLID LID
DECIDUOUS TREE W/DRIPLINE TO SCALE STORM DRAIN LINE
SIMILAR
E/O EXIT ONLY Sim
D/N DO NOT ENTER SHT SHEET
0 AREA DRAIN (LG=LARGE 18"-24" DIA, SM=1.0' SQ) DEMOLISH CROSSWALK MARKINGS
HC HANDICAP SS SANITARY SEWER YARD DRAIN
L/T LEFT TURN ONLY STD STANDARD STORM DRAIN CLEAN OUT CONIFEROUS TREE W/DRIPLINE TO SCALE
N/P NO PARKING TESC TEMPORARY EROSION AND SEDIMENT CONTROL ..... . . . . . . m TYPE 1 CATCH BASIN
. . . DEMOLISH LANDSCAPE
PED PEDESTRIAN TC TOP OF CURB PLENUM (PER REF#) 00 TREE IDENTIFICATION NUMBER PER ARBOR I
P/D PRIVATE DRIVE TW TOP OF WALL IST REPORT (REF. 11) 111111110- FLOW DIRECTION
S/N STREET NAMES TYP TYPICAL SANITARY SEWER MANHOLE 1�w' DEMOLISH STRUCTURE SPOT ELEVATION
R/T RIGHT TURN ONLY W/ WITH WATER VALVE wv xxx.XX
W WEST/WATER STORM DRAIN CLEANOUT (SDCO)
WSDOT WASHINGTON STATE DEPARTMENT OF TRANSPORTA11ON
YD YARD DRAIN ........................ RIDGE LINE
CITY OF EDMONDS GENERAL NOTES
1. ALL MATERIALS AND WORK SHOWN ON THESE PLANS SHALL 6. ELEVATIONS SHOWN ARE IN FEET. SEE SURVEY FOR BENCHMARK 11. CONTRACTOR SHALL OBTAIN A COPY OF THE GEOTECHNICAL 18. ALL ROOF DRAINS, PERIMETER FOUNDA-flON DRAINS, CATCH BASINS 25. THIS PROJECT IS NOT A BALANCED EARTHWORK PROJECT. BOTH 32. EXISTING U11LITY LINES IN SERVICE MICH ARE DAMAGED DUE TO
CONFORM TO THE CITY OF EDMONDS STANDARD PLANS AND INFORMATION. REPORT (WHERE APPLICABLE) AND SHALL THOROUGHLY FAMILIARIZE AND OTHER EXTERNAL DRAINS SHALL BE CONNECTED TO THE EXPORT AND IMPORT OF SOIL AND ROCK MATERIALS ARE REQUIRED. CONSTRUCTION WORK SHALL BE REPAIRED AT CONTRACTOR'S
DETAILS, THE FOLLOWING SPECIFICATIONS AND CODES, AND ALL 7. THE LOCA11ONS OF EXISTING UTILITIES AND SITE FEATURES SHOWN HIMSELF WITH THE CONTENTS THEREOF. ALL SITE WORK SHALL BE STORM DRAINAGE SYSTEM, UNLESS NOTED OTHERWISE. 26. SLOPE OF FINISHED GRADE SHALL BE CONSTANT BETWEEN FINISHED EXPENSE AND INSPECTED AND ACCEPTED BY CITY OF EDMONDS
OTHER APPLICABLE LOCAL MUNICIPAL, STATE, AND FEDERAL CODES, HEREON HAVE BEEN FURNISHED BY OTHERS BY FIELD SURVEY OR PERFORMED IN STRICT COMPLIANCE WITH THE RECOMMENDA11ONS 19. ALL FOOTING DRAINS SERVING BUILDINGS, WALLS, ROCKERIES, ETC. CONTOURS OR SPOT ELEVATIONS SHOWN. AND OWNER'S REPRESENTATIVE PRIOR TO BACKFILLING.
RULES AND REGULATIONS: OBTAINED FROM AVAILABLE RECORDS AND SHOULD THEREFORE BE OF THIS REPORT. SHALL CONNECT TO THE DRAINAGE SYSTEM DOWNSTREAM OF THE 27. FINISHED GRADE SHALL SLOPE AWAY FROM BUILDING WALLS AT 33. NEW U11LITY LOCATIONS ARE GENERALLY SHOWN BY DIMENSION,
- CURRENT INTERNATIONAL BUILDING CODE (IBC) CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. 12. STRUCTURAL FILL MATERIAL AND PLACEMENT SHALL CONFORM TO SITE STORMWATER DETEN11ON SYSTEM.
- 2014 WSDOT/APWA STANDARD SPECIFICATIONS
FOR ROAD, BRIDGE AND MUNICIPAL
CONSTRUCTION
- WASHINGTON STATE DEPARTMENT OF ECOLOGY
STORMWATER MANAGEMENT MANUAL FOR THE
PUGET SOUND BASIN (CURRENT EDITION)
2. STANDARD PLAN AND TYPE NUMBERS INDICATED ON THESE
DRAWINGS REFER TO CITY OF EDMONDS STANDARD DETAILS,
UNLESS NOTED OTHERWISE.
3. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOBSITE
WHENEVER CONSTRUCTION IS IN PROGRESS.
4. DEVIA11ONS FROM THESE PLANS MUST BE APPROVED BY THE
ENGINEER OF RECORD AND THE LOCAL GOVERNING AUTHORITY.
5. CONTRACTOR SHALL RECORD ALL APPROVED DEVIATIONS FROM
THESE PLANS ON A SET OF "AS -BUILT" DRAWINGS AND SHALL
SUMMARIZE ALL ASBUILT CONDITIONS ON ONE SET OF
REPRODUCIBLE DRAWINGS FOR SUBMITTAL TO THE OWNER PRIOR
PROJECT COMPLETION AND ACCEPTANCE. A SET OF AS-9U)LT
DRAWINGS SHALL BE SUBMITTED TO THE CITY OF EDMONDS PRIOR
TO FINAL APPROVAL OF THE BUILDING OCCUPANCY/FINAL PROJECT
APPROVAL.
IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO THE RECOMMENDATIONS OF THE PROJECT GEOTECHNICAL REPORT.
INDEPENDENTLY VERIFY THE ACCURACY OF ALL U11LITY LOCATIONS
SHOWN AND TO FURTHER DISCOVER AND PROTECT ANY OTHER
UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE
IMPLEMENTATION OF THIS PLAN. CONTRACTOR SHALL VERIFY
LOCATION, DEPTH, SIZE, TYPE AND COND11ION OF EXISTING UTILITY
LINES AT CONNEC11ON OR CROSSING POINTS BEFORE TRENCHING
FOR NEW UTILITIES. ENGINEER ASSUMES NO RESPONSIBILITY FOR
THE COMPLETENESS OR ACCURACY OF THE EXISTING UTILITIES AND
SITE FEATURES PRESENTED ON THESE DRAWINGS. ENGINEER SHALL
BE N011FIED IMMEDIATELY OF CONFLICTS THAT ARISE.
8. CONTRACTOR SHALL LOCATE AND PROTECT ALL U11LITIES DURING
CONSTRUCTION AND SHALL CONTACT THE UNDERGROUND UTILITIES
LOCATION SERVICE (1-800-4-24-5555) AT LEAST 48 HOURS PRIOR
TO CONSTRUCTION.
9. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT
THE PROJECT SITE BEFORE STARTING WORK AND SHALL N01IFY
OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES.
13. SUBGRADE SOILS IN ALL AREAS WHERE RAIN GARDENS,
INFILTRA11ON OR PERVIOUS PAVEMENT IS TO BE PLACED SHALL BE
DELINEATED AND PROTECTED AT ALL 11MES FROM COMPACTIVE
ACTIVITIES (i.e. HEAVY EQUIPMENT, STOCKPILING).
14. MANHOLES, CATCH BASINS, UTILITIES AND PAVEMENT SHALL BEAR
ON MEDIUM DENSE TO VERY DENSE NATIVE SOIL OR COMPACTED
STRUCTURAL FILL. IF SOIL IS DISTURBED, SOFT, LOOSE, WET OR IF
ORGANIC MATERIAL IS PRESENT AT SUBGRADE ELEVATION, REMOVE
AND REPLACE WITH COMPACTED STRUCTURAL FILL PER
GEOTECHNICAL REPORT.
15. SEE SURVEY ANB AR6HITE6TURAI: DRAWINGS FOR DIMENSIONS AND
LOCATIONS OF BUILDINGS, LANDSCAPED AREAS AND OTHER
PROPOSED OR EXISTING SITE FEATURES.
16. SEE ARGIIIT-EePdRAL DRAWINGS FOR PERIMETER FOUNDATION
DRAINS. FOUNDA11ON DRAINS SHALL BE INDEPENDENT OF OTHER
SITE DRAIN LINES AND SHALL BE TIGHTLINED TO THE STORM DRAIN
qY'RTFM M4FRF imnirATFr) ON THF PI ANq
10. PIPE LLNGJN,� WHERE SHOWN ARE APPROXIMAIL ANU MAY CHANGL
DUE TO FIELD CONDITIONS. 17.
ALL REQUIRED STORMWATER FACILITIES MUST BE CONSTRUCTED AND
IN OPERATION PRIOR TO INSTALLA11ON OF ANY PAVEMENT UNLESS
OTHERWISE APPROVED BY THE ENGINEER.
MINIMUM 07o tiLLIFt I UK A MINIMUM DISTANCE OF 10 FEET. WHERE NO DIMENSIONS ARE INDICATED, LOCATIONS MAY BE SCALED
20. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED 28. CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL INSTALL AND FROM DRAWINGS. FIELD ADJUSTMENTS SHALL BE APPROVED BY
FOR INSTALLATION OF ALL SITE IMPROVEMENTS INDICATED ON MAINTAIN SHORING AND BRACING AS NECESSARY TO PROTECT OWNER'S REPRESENTATIVE AND CITY.
THESE DRAWINGS. WORKERS, EXISTING BUILDINGS, STREETS, WALKWAYS, UTILITIES AND 34. FIELD STAKE ALL UTILITY STUBS AT THE PROPERTY LINE.
21. A SEPARATE IRRIGATION PERMIT MUST BE OBTAINED FROM THE OTHER EXISTING AND PROPOSED IMPROVEMENTS AND EXCAVATIONS 35. TRENCH BACKFILL OF UTILITIES LOCATED WITHIN THE CITY
CITY PUBLIC WORKS DEPARTMENT. PRIOR TO FINAL CONSTRUCTION AGAINST LOSS OF GROUND OR CAVING EMBANKMENTS. RIGHT-OF-WAY SHALL BE COMPACTED TO 95%. COMPAC11ON TEST
ACCEPTANCE, PROVIDE TO THE CITY WATER QUALITY TECHNICIAN, A CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR REMOVAL OF REPORTS SHALL BE PROVIDED TO THE CITY PRIOR TO PAVING.
COPY OF THE BACKFLOW TEST REPORT. TEST REPORTS CAN EE SHORING AND BRACING, AS REQUIRED.
FAXED TO 425-744-6057 OR EMAILED TO 29. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY AND 36. WHERE NEW PIPE CLEARS AN EXISTING OR NEW UTILITY BY 6" OR
LINDA.MCMURPHY@EDMONDSWA.GOV. BACKFLOW TESTING SHALL BE FOLLOW CITY PROCEDURES FOR ALL WATER SERVICE LESS, PLACE POLYETHYLENE PLASTIC FOAM AS A CUSHION
COMPLETED BY THE OWNER ANNUALLY THEREAFTER. INTERRUPTIONS, HYDRANT SHUTOFFS, STREET CLOSURES OR OTHER BETWEEN THE UTILITIES.
22. AS A MINIMUM REQUIREMENT, ALL DISTURBED AREAS ON AND OFF
SITE SHALL BE RETURNED TO THE EQUIVALENT OF THEIR
PRECONSTRUCTION COND11ION IN ACCORDANCE NTH APPROPRIATE
REQUIREMENTS AND STANDARDS.
23. ALL DISTURBED SOIL AREAS SHALL BE COMPOST AMENDED AND
SEEDED OR STABILIZED BY OTHER ACCEPTABLE METHODS FOR THE
PREVENTION OF ONSITEEROSION AFTER THE COMPLETION OF
CONSTRUCTION. SEE EROSION CONTROL PLANS FOR SPECIFIC
GRADING AND EROSION CONTROL REQUIREMENTS.
24. THE CONTRACTOR SHALL KEEP OFF -SITE STREETS CLEAN AT ALL
TIMES BY SWEEPING. WASHING OF THESE STREETS WILL NOT BE
ALLOWED WITHOUT PRIOR APPROVAL.
ACCESS RESTRICTIONS. CONTRACTOR SHALL NOT RELOCATE OR
37.
SEE MECHANICAL DRAWINGS
(WHERE APPLICABLE) FOR
ELIMINATE ANY HYDRANTS WITHOUT FIRST OBTAINING WRITTEN
CONTINUATION OF SITE UTILITIES WITHIN THE BUILDING.
APPROVAL FROM THE. FIRE MARSHAL.
30. COORDINATE AND ARRANGE FOR ALL UTILITY CONNECTIONS, UTILITY
38.
SEE ELECTRICAL DRAWINGS
(WHERE APPLICABLE) FOR EXTERIOR
ELECTRICAL WORK.
RELOCATIONS AND/OR SERVICE INTERRUPTIONS NTH THE AFFECTED
OWNERS AND APPROPRIATE UTILITY COMPANIES. CONNECTIONS To
39.
SEE LANDSCAPE DRAWINGS
(WHERE APPLICABLE) FOR SITE
EXISTING UTILITIES SHALL BE MADE ONLY NTH ADVANCE WRITTEN
IRRIGATION SYSTEM.
APPROVAL OF THE AUTHORITIES GOVERNING SAID UTILITIES.
AO
PIP17 kAA-MPIAI AKIr) CIPKIAPE'
CHOL11
31. ALL U11UTIES SHALL BE PLACED UNDERGROUND.
I IMLa WILL BE PRO DED 10
CITY ENGINEERING DIVISION FOR APPROVAL PRIOR TO INSTALLATION.
DRAWN BY DESIGNED BY .13 S i EDMONDI SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS SHEET
KWP/TY AJS v WA APPROVED FOR CONSTRUCTION
CHECKED BY APPROVED BY Call 811 CITY OF EDMONDS EDMONDS, WASHINGTON
0 two business ]days 1601 5th Av
C1 �in� enue, Suite 1600
TJE TJE Ig
DATE Fgbefore y:oudig Seattle, WA 98101 DATE: 31w gwIf- RESUB
206.622.5822
05/27/2015 lqjff www.kpff.com 76 JUN 0 12015 GO.02
S C A L E: IST B LEGEND, ABBREVIATIONS, AND GENERAL NOTES
10 MY E01NEERING DIASION SCH(OL BUILDING DEPARTMWr
DATE BY CHD. APPR. REVISION JOB No. :114407 AS SHOWN DISTRICT CITY OF EDMONDS FOR PERMIT
LEGEND
GO
L'i
C/)
C—)
(in
-0
0
0
(D
C/)
r-)
(J)
CD
m
4-
LLj
E
0
00
--t-
Q6
F-
I
I 1111'L dF Es, L112i 3 A AqL�
NW CORNER SEC. 36-27N-3E
2000 COUNTY CON1RO1.j =4
VASHINCION COORDINATE SYSTEM NORTH 20NE NAD 119821/91
PER WASHINGTON GEODETIC SUM DATABASE 0# 218M
It 29=13M
E- 12MM947
V1. =53 FM 2.50 BRASS DOME DW ij
Uj
HU FOR POSITION W/011IMED T IN A CONC. MONUMENT cl
c\j
GRID & GROUND COORDINATE DOYM :KS IN MONUMIW CASE c"j
HELD AT 71E NORTH LINE W (M SEC. 36-27N-3E CD
I-D
AND FOR CENMINE 1067H AVE W. PER PLAT SEE REF.1 2: cD
AND MONUMW LINE FOR ZM ST. SW PER PLAT SEE REF.7
1316.06 C (1315.80 P)
658.16 M (657.90 P) 4/4
"I I 228TH STREET SW
I
L
N88*36'06"'W
229TH PLACE SW
�2 MIND STONE Mmmw;;—\
C-4 Tm CHISEUED
LL:
LLJ DOW :H.O` IN MONIAMIT CASE
0.07V x MOrS OF CAIAIIAIED
POSITION PER REF2
N88'33'44"W 660.68 REF1(659.80 P)
MONUMIENT POSMON PER 1U.2
(NOT Vm THIS sum"
0. 13 11,�' 113 - 3_� I "I",
2:4:1�3;P4111 i� 41�1
I L
1,188*33'44"W N8 '53`22"W
�L 8 3
231ST STREET SW
L
\_f= BR= T N88-39'31"W 6J9.28 REF.5 (659.84 P)
= If MOM MOMA931T
DO0 JAr N MONUMENT CASE CAIAIII.ATED MONUMENT POSITION PER .7-�
HELD AS ALIGNMENT FOR 1061H AVE. Sff (NOT VMED THIS MW
DRAWN BY DESIGNED BY
xxxx xxxx
royn Call 811
CHECKED BY APPROVED BY o@ two business days
TJE xxxx * before you dig
DATE
04/15/2015
C =HD APPR. REVISION J 0 B No. - 114407 AS '_�:)'HOWN
N 0. DATE B Y
--------------
_SS_
- SD—
_w_
_G —
—OHP
_0HPT—
_0HT—
_p_
T
MONUMENI` NOT /—NORTH QR 0=0 SEC. 36-01—M
SEARCHED FOR SNOHOMISH COUNTY SUM CONITROIJ SC33
CMDAA7ED POSITION WASHINGTON COORDIINATE SYSTEM N" ZONE
PER PIAT REFA NAD 1983M PER WAS94M GEODETIC
/ SURVEY DATABASE ID# ZW
21 N: MM0574
73'_6 I- 1XIMM
HOD FM BEAMG
GO COORDINATE
(NOT VWED THIS sumwy)
------ -----------
1601 5th Avenue, Suite 1600
Seattle, WA 98101
206.622.5822
1Tff www.kpff.com
SURVE (ED TOP OF SLOPE
SURVE'iED TOE OF SLOPE
TOP OF DITCH
CEIITEPLIHE OF DITCH
DRAIIIAGE FLOW LIHE
BIJILDI( IG
ROOF LINE
FEI10E
EDGE OF ASPHALT
SAHITARY SEWER
STORM OF AIH
WATER
GAS
OVERHEAD POWER
OVERHEAD POWER &I COMMUHICATIO16
OVERHEAD C(__jIAMI_II,IICATIOHS
UIIDEPGROUHD POWER
UHDERCPOUI\ID COMMUNICATIONS
CEHTEPLIHE RIGHT—OF—WAY
PUBLIC LAND _--UPVE( SYSTEM SSUBEGISIO11 LINE
ADJACEHT BCJUI,IDAPI' LIIIE
BRUSH LINE
BASIS OF BE4RINGS
H?816'44"W ALOIIG THE HOPTH LIIIE OF THE HOPTHWEST 1/1.
SECTIC)f 1 56, TOWI 1,--,HIP 27 11 , FAI 1(--,E -1 E W M,
I JAD 198_3� 91 WAc�Hll IGTOI I COOPDI1 IATE �. i"TEM I IOPTH _OHE
HORIZONTAL DATUM
WASHINGTON STATE COORDIHATE S(STEM, 110PTH __11_111E
HAD 19108.'91
VER TICA L DA TUM
HAVE) 83
BENCHMARK
SIIOHOMI'1H COUHTi (0IITPOL POI1IT# '__.C__)4 �ALSO KHOW11 AS
21=CAD# VERTICAL CONTROL P01114
FOUHD IIIVEPTED IIAIL III COHCPETE MO1IUI,1EiIT DOW(] ±0.3' IN
MOIIUMEIIT CASE AT THE 3 WA( 111TEPSECT1011 OF 103TH AVE
W AIJD 11 DEEP DR.
ELEVATC)11=252_5_`�
4-13-15
14711 NE 29th Place Suite 101
Bellevue, Washington 98007
DESI G N 425.885.7877 Fox 425.885.7963
ENGINEERING - PLANNING -SURVEYING
Q
STORM DRAIN MANHOLE
'STORM DRAIN CATCH BASIN
STORM DRAIN CATCH BASIN W/SOLID LID
0
AREA DRAIN (LG=LARGE 18"-24" DIA, SM=1.0' SO)
STORM DRAIN CLEAN OUT
PLEHUM (PER REF#)
SANITARY SEWER MANHOLE
N
WATER VALVE
C�
FIRE HYDRANT (ELEVATION OF FLANGE)
M
WATER METER
WATER VAULT
IRRIGATIOH VALVE
,09
UTILITY POLE W/LUMINAIRE (WOOD)
UTILITY POLE (WOOD)
GUY ANCHOR
PARKING/AREA LIGHT (METAL)
YARD LIGHT
B
ELECTRIC JUNCTION BOX
ELECTRIC METER
ELECTRIC SERVICE (OUTLET)
COMMUNICATIONS BOX (PROVIDER HOTED)
GASVALVE
GAS METER
UTILITY (UNKHOWN TYPERROVIDER)
0
BOLLARD
0-
FLAGPOLE
SIGH
MAIL BOX
TEST PIT
+
WETLAIID FLAG
KEYSTOHE/BLOCK WALL (UNLESS NOTED)
ROCKERY
DECIDUOUS TREE W/DPIPLIHE TO SCALE
COHIFEROUS TREE W/DRIPLINE TO SCALE
TREE ID71HTIFICATICH NUMBER PER ARBORIST REPORT (REF. 11)
REFERENCES
ASPH
ASPHALT
C
CALCULATED
CONC
CONCRETE
D/W
DRIVEWAY
ELEV
ELEVATION
E/M
ELECTRIC METER
EXC
EXTRUDED CURB
F/H
FIRE HYDRANT
GVL
GRAVEL
LOC
LOCATE/LOCATION
LP
LIGHT POLE
M/B
MAILBOX
M
MEASURED
OS
OIL SEPARATOR
P
PLAT
P. N.
PARCEL NUMBER
P/A
PLANTER AREA/STRIP
P/B
PLANTER BOX (RAISED)
RCG
ROLLED CURB AND GUTTER
RET
RETAINING
RRT
RAILROAD TIE
TFMR
TRANSFORMER
TYR
TYPICAL
UGC
UNDERGROUND COMMUNICATIONS
UGP
UNDERGROUND POWER
UP
UTILITY POLE
VCB
VERTICAL CURB
VCG
VERTICAL CURB & GUTTER
W/V
WATER VALVE
FENCING
CLF
CHAIN LINK FENCE
HBF
HORIZONTAL BOARD FENCE
VBF
VERTICAL BOARD FEI,ICE
HRF
HORIZONTAL RAIL FEHCE
TREES
A
ALDER
B
BIRCH
C
CEDAR
CLST
SMALL TRUNK CLUSTER
CHF
CONFIER (UNDETERMIHED SPECIES)
DEC
DECIDUOUS (UNDETERMINED SPECIES)
F
FIR
HOG
HEDGE
#"/#"
MULTIPLE DIFFERENT TRUNK DIAMETERS
#x#"
MULTIPLE LIKE TRUHK DIAMETERS
SIGNS
B/O
BUSES ONLY
D/E
DEAD END
D //N
DO NOT ENTER
E /0
EXIT ONLY
HC
HANDICAP
L/T
LEFT TURN ONLY
14 /P
NO PARKING
RED
PEDESTRIAN
P/D
PRIVATE DRIVE
S/N
STREET NAMES
R/T
RIGHT TURN ONLY
&
NOTE REFERENCE (SEE PAGE I OF 4)
I. PLAT OF FICHMOHD BEACH GARDEN TRACTS, RECORDED IN VOLUME 8 OF PLATS, PAGE 54, RECORDED UI,IDER AF11 IJ5906,
FE(_OPDS OF '11011C4,111SH COUIIT'f, WASHIHGTON.
HOLIDA) HILL, PE(-,C)PDED III VOLUME 15 OF FLATS, PACE 49, RECORDED UNDER AFN 1135315, RECORDS OF SHOHOMISH
COUNTY, WA'-jH1IIGT0I,I.
W STGATE MANOR, RECORDED IN VOLUME 23 OF PLATS, PACE 86, RECORDED UHDEP AFN 1684299, RECORDS OF
E,
SHOHOMISH CO(J[JT),, WASHIFIGTO11.
4, MAFIL'dIIIE ADDiFIOII, RECORDED III VOLUME 24 OF PLATS, RACE 114, RECORDED UNDER AFt�j 1814421, RECORDS OF
.)II0HOMI*3H COUHTY, WASH114GTOH.
5. SHERWOOD ESTATES, RECORDED III VOLUME 31 OF PLATS, PAGE 90, RECORDED UNDER AFN 2147238, RECORDS OF
SNOHOMISH COUI]T(, WASHIIJGTOH.
6. WESTGATE ESTATE�, RECORDED 111 VOLUME 20 OF PLATS, PAGE 121, RECORDED UNDER AFN 1513657, RECORDS OF
5,110HOMISH COUNTf, WASH 111 GTON.
7. RECORD OF SUPVE( FOR PAYMOIAD ROCIISTEAD DATED DECEMBER 3, 2001, RECORDED UNDER AFN 200112045003, RECORDS
OF SHOHOMISH COUHTY, WASH 111 GTON.
.0, DIVISIOII 110— OF WESTGATE PAPI�, RECORDED TI VOLUME 13 OF PLATS, PAGES 40-41, RECORDED UHDER AFN 966230,
RECORDS OF SHCHOMISH COUNTY, WASHII\IGTOH.
9� SHERWOOD ELEMEHTARf SCHOOL EDMONDS SCHOOL DISTRICT 110. 15 CIVIL ENGINEERII,IG PLAN SHEET NO. MIO, PREPARED
BY REID, MIDDLETON AND ASSOCIATES UNDER JOB NO. 66-6 FOR ROBERT A. BEZZO — ARCHITECT, DATED NOVEMBER 7,
1966.
10. CITY OF EDMONDS GIS STORm WATER DATA ACCESSED VIA THE INTERNET.
11� WASHIIAGTOII GEODETIC SURVEY, SURVEY DATA WAREHOUSE FOR SNOHOMISH COUNTY SURVEY CONTROL.
LEGAL DESCRIPTION
TRACTS 6, 7 AHD 8, RICHMOND BEACH GARDEN TRACTS, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 8 OF PLATS,
ON PAGE 54, RECORDS OF SNOHOMISH COUNTY, WASHINGTON.
NOTES
1. ALL TITLE I I'l FORM ATION SHOWN 014 THIS MAP HAS BEEN TAKEN FROM PUBLIC RECORD. 110 TITLE POLICY WAS
COMMISSIOIIED FOR THIS PROJECT THEREFORE CORE DESIGH, INC. QUALIFIES THE MAP'S ACCURACY AND COMPLETENESS TO
THAT EXTEIIT.
2 THIS SURVE) PEPPES'EIITS VISIBLE PHYSICAL IMPROVEMENT CONDITIONS EXISTING Oil NOVEMBER 3, 2014. ALL SURVEY
COHTPOL INDICATED AS "FOUND" WAS RECOVERED FOR THIS PROJECT IN OCTOBER, 2014.
PPOPERT ( AREA = 593,598 5± SQUARE FEET (13,6271 ± ACRES).
4. ALL DISTAHCES APE IN FEET.
5 THIS IS A FIELD TRAVERSE SURVEY. A SOKKIA FIVE SECOND COMBINED ELECTRONIC TOTAL STATION WAS USED TO
MEASURE THE AI,IGULAR AIID DISTAHCE RELATIONSHIPS BETWEEN THE COI,,ITROLLII,IG MONUMENTATION AS SHOWN. CLOSURE
RATIOS OF THE TRAVERSE MET OR EXCEEDED THOSE SPECIFIED IN WAC 332-130-090 ALL MEASURING INSTRUMENTS AND
EQUIPMENT ARE MAIIITAIHED IN ADJUSTMENT ACCORDING TO MANUFACTURER'S SPECIFICATIONS.
6. UTILITIES OTHER THAN THOSE SHOWN MAY EXIST 011 THIS SITE. ONLY THOSE UTILITIES WITH EVIDENCE OF THEIR
IIISTALLATION VISIBLE AT GROUND SURFACE ARE SHOW11 HEREON. UNDERGROUND UTILITY LOCATIONS SHOWI\I APE
APPROXIMATE ONLY. UNDERGROUND CONNECTIONS ARE SHOWN AS STRAIGHT LINES BETWEEN SURFACE UTILITY LOCATIONS
BUT MAY COFITAIN BENDS OR CURVES NOT SHOWN. SOME UNDERGROUND LOCATIONS SHOWN HEREON MAY HAVE BEEH
TAKIE11 FROM PUBLIC RECORDS. CORE DESIGN ASSUMES NO LIABILITY FOR THE ACCURACY OF PUBLIC RECORDS.
EDMONDS
ELEMEkITARY 1_)CH00L TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS
EDIVIONDS, WASHINGTON
SCHODL
DISTRICT
SURVE \11
RESUM
JUN 0 12015
BUILDING DEPARTMENT
017Y OF EDMONDS
SHEET
(7�vo 1 (_ I
IJ I_ 0 k )
FOR PERMIT
C!
C)
.Sh
0)
0)
(V
LLI
-0
0
0
-3:::
V)
(n
C)
C�l
LJ
13)
FE
E
L2
LO
3 E
C14
DRAWN BY DESIGNED BY
xxxx xxxx
0 Call 811
CHECKED BY APPROVED BY o two business days
TJE xxxx before you dig
DATE
04/15/2015
REVISION JOB No. :114407 AS SHOWN
1601 5th Avenue, Suite 1600
Seattle, WA 98101
206.622.5822
1q)ff . www.kpff.com
14711 NE 2M Place Sulte 101
Bellevue, Washington 98W7
425.W5.7877 Fax 42&W&703
EN GINEERING - PLANNING -SUR VEY
P.N. 27032500306200
/-MONUMENT NOT
SEARCHED FOR
CALCULATED POS111ON
PER PLAT REF.1
3
P.N. 00610700100200
-d 0.
0 \� 0
2 .
N. 00610700100200 10\1
? o" xv
,�GOo' ?qGbb?-bo
0�'5q6- �04
1
4 '0C, Ibb
00610700100403 40� gbl
v oj&
C'ov\x g@-"'
I
I 1 05 r
1610700100403 40\A '04
C
EDM SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS
IN &F, EDMONDS, WASHINGTON
SCHGDL
DISTRICT
SURVEY
RESUB
JUN 0 12015
BUILDING DEPARTMENT
CITY OF EDMONDS
4-13-15
SHEET
411:14 � 4:14 J] I I i
C�
.21
u3
E
Q,
Uj
-a
0
0
c�
C)
w
FE
DRAWN BY DESIGNED BY
E xxxx xxxx Call 811
CHECKED BY APPROVED BY C
two business days
TJE xxxx
E:before you dig
CD
I --, DATE
g
C>
04 15/2015
S C A L E:
J 0 B
NO. DATE BY CHID. APPR. REVISION No. :114407 AS SHOWN
>< I i I I I
1601 5th Avenue, Suite 1600
Seattle, WA 98101
206.622.5822
1cpff www.kpff.com
P.N. 00610700100403
0 0� 6'o
99
5
P.N. 00610700100500
ol
C)r?,.
G ro
D-
C'4 6
to
P.N. 00610700100600
LU
a
C14
P
to
p
CD
4
P.N. 00610700100703
o
r
SY06
1
P.N. 00610700100903
4-13-15
1� r0ro
'055,
CO 119
401 gt\
SCALE: 1 30
0 30 so
I
N111111111M mommonloommm
EDMONDI SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS
,&91ft m=b, mm) EMN 4A744 MV 00M Dinpa Cho" 4M a &M EDMONDS, WASHINGTON
SURVEY
RESUM
JUN 0 12015
BUILDING DEPARTMENT
r,ITY OF EDMONDS
SHEET
is A44a�
LO
I
C�
-R
cn
I
Qf
.21
co
IV
E
-2
0
cy)
E
V
LO
LO
r.0
LO
E M-1-1
REVISION
. i" N X i
DRAWN BY DESIGNED BY
xxxx xxxx Call 811
CHECKED BY APPROVED BY C
tw'o business days
t
TJE xxxx [:before you dig
D ATE
04/15/2015
JOB No. :114407 AS SHOWN
1601 5th Avenue, Suite 1600
Seattle, WA 98101
206.622.5822
www.kpff.com
1cp'ff
EDMONDS
4
P.N. 00610700100703
(fi 0
5\Ac;?-,
1 '0-5 ,ro
'00A W
�0 5.1
P.N. 00610700100903
r
- — — — —__j—
4-13-15
\"-CALCULATED MONUMENT POS111ON PER REF.7 SCALE: 1 30'
(NOT VISITED THIS SURVEY) 0 .30 60.
SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS
EDMONDS, WASHINGTON
RESUS
SURVEY jUN c 12015
P'U'L 4G DEPARTMENT
,,ffl" OF EDMONDS
SHEET
FOR PERMIT
Ci-
V)
CD
C
Cn
M
C-)
co
C)
LjJ
_0
0
0
C,
M
CY)
�3
E; <-D
LLJ
W
LLJ
CIO
E X
LLJ
0 =
00
E
Lz
(D
><
PROJECT CONTROL POINT #3
FOUND INVERTED NAIL IN CONC. MONUMENT DOWN
±0.8' IN MONUMENT CASE NW CORNER SEC.
36-27N-3E SNOHOMISH COUNTY CONTROL# SC34
WASHINGTON COORDINATE SYSTEM NORTH ZONE NAI
1983/91 PER WASHINGTON GEODE11C SURVEY
DATABASE ID# 21881
N: 292836.7771
E: 1260878.947
V: 258.526
HELD FOR POS11ION GRID & GROUND COORDINATE
__1 — —
M
C,
PROJECT CONTROL POINT #2
M
FOUND 2.5" BRASS DO E DISK W/CHISELED "X" IN A
M
9.9 0.03' LT 0�_
STA 09+9 �0 CONC. MONUMENT DO ±0.3' IN MONUMENT CASE
I 'I A �� ��
FOUND BRAS TACK IN CONCRETE MCNUMENT -E
HELD AT THE NORTH LINE NW QTR SEC. 36-27N-3E
CD DOWN ±1.4' 1 MONUMENT CASE 0.03'W x
OE I -M AND FOR CENTERLINE 196TH AVE. W. PER PLAT SEEI
CALCULATED INTERSECTION PER M -P
0.04'S OF TH I I I I I REF 1 AND MONUMFNT INF FnP 99RT14 U (ZW PP
REF.2 & REF.5 PLAT SEE REF.7
N = 292820.84
PARENT DRIVE LANE/ AND 7— E = 1261536.91 0
I
DROP-OFF AT CURB
F
Ct ASLAND��ONE WAY C>
13+00 14+00 15+OD 16+00 17+00 18+00
11+00 12+00 1 — i 19+M 20+00
-4— Z+00
106TH AVE. W.
ct CZ Ci
C /7 77-\\\/
7,.- - 7777-7
7,
PARENT PARKING
1 PARENT ACCESS DRIVE
CONSTRUCTION BASELINE -a- /*
AND PARKING, TWO
06TH AVENUE CENTERLINE
RIGHT -ONLY AND LEFT -ONLY N, %
ONE-WAY LANES 1.0c
TURN LANES AT EGRESS TO RAIN GARDEN #02 1
X
'02 02 PROJECT CONTROL POINT #1
I PROPERTY LINE 196TH AVE, ONE WAY
co
CALCULATED INTERSECTION Od
'D 0 n CIO
106TH AVENUE WEST AND
231ST STREET SW I
I F_
N 291686.06
............
1�; co L I
...........
E 1261514.89 ..........
M
. . . . . . . . . .
t - -
- - - - - - - - - - -
El
=-7
SHERWOOD
ELEMENTARY
. . . . . . . . . . . . . . . ADA, STAFF AND BUS
PARENT DRIVE LANE
AND
DROP-OFF AT EXISTING
ACCESS DRIVE, TWO WAY
?
'�'�RAIN GARDEN #01
CURB, ONE WAY
............. APPROXIMATE LIMIT OF
YZZZZZZZZZZZZZ/l L BUS -ONLY DRIVE LOOP
PROPERTY LINE (TYP)
AND DROP-OFF, ONE WAY WORK (TYP)
SHUTTLE VAN DRIVE LOOP
L INSIDE TURN RADIUS NOTES:
OF 20.0' (TYP)
1. REFER TO SHEET GO.02 FOR GENERAL NOTES.
F A
5' PEDESTRIAN WALKWAY 2. CONSTRUCTION BASELINE IS THE CENTERLINE OF 106TH 1.0c
15 ADA AND DAYCARE
FROM STAFF PARKING
FIRE APPARATUS ACCESS
SHUTTLE VAN DRIVE Loop, AVENUE AND IS DEFINED AS A LINE BEARING N01006'38"E
AND PASSING THROUGH PROJECT CONTROL POINT #1 AND
ONE WAY
LANE (TYP) PROJECT CONTROL POINT #2.
ADA AND SHUTTLE DROP STAFF -ONLY PARKING,
3. PRIOR TO CONSTRUCTION ACTIVITY, CONTRACTOR SHALL FIELD
TWO WAY
OFF AT 8' ODE ISLAND LOCATE THE PROJECT CONTROL POINTS AND IMMEDIATELY
FF_ SHUTTLE VAN DRIVE LOOP REPORT AND DISCREPANCIES TO THE ENGINEER.
OUTSIDE TURN RADIUS OF
4. FIRE APPARATUS ACCESS LANES PROVIDE 25.0' MIN INTERIOR
L
31.0' (TYP)
L J ...... L-1 L-1 RADIUS AND 45.0' MIN EXTERIOR RADIUS FOR TURNING.
PROJECT DESCRIPTION:
CONCRETE RAMP FOR FIRE
THE OVERALL PROJECT GOAL IS TO IMPROVE TRAFFIC AND APPARATUS ACCESS
PEDESTRIAN SAFETY AT SHERWOOD ELEMENTARY SCHOOL. WORK
INCLUDES REORGANIZATION OF PARKING AND PICK-UP/DROP-OFF
ZONES TO IMPROVE EFFICIENCIES AND REDUCE PEDESTRIAN,
VEHICLE, AND BUS CONFLICTS. AS PART OF SITE REORGANIZATION,
THE PROJECT WILL CONSTRUCT NEW AND REPLACED PAVEMENT
77
.02
FOR TRAFFIC AND PEDESTRIAN IMPROVEMENTS. LANDSCAPE AREAS
ADJACENT TO PARKING AND DRIVE LANES WILL BE RE -GRADED TO 268' STORAGE SHED,
ACCOMMODATE EXPANSION OF PAVED AREAS. A NEW STORMWATER SEE SHEET C4.02
SYSTEM WILL COLLECT AND CONVEY RUNOFF FROM IMPROVED "Nothing in this pemit approval process shall be
AREAS TO TWO RAIN GARDENS FOR WATER QUALITY TREATMENT �n��r!�� as allowing or permitting the P0 5pec glu,�wlphvt
AND ON -SITE INFILTRATION.
e of any currently existing ulega4
nonco oTin orur ermitted building, structure
sit4 dit g
ion Ili
g
or is outside the scope of the
germit application, regardless of whether such
uilding, structure or condition is shown on the
site plan or drawing. Such building, structure or
condition may be the subject of a separate
enforcement action."
NMOW'221
106TH AVE. W.
'0
co
co
105TH AVE. W.
_I_7T T
____1 __�_L
20 40 80
1 inch = 40 feet
DRAWN BY DESIGNED BY 9 J Z, EDMONDS SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS SHEET
KWP/TY AJS APPROVED FOR CONSTRUCTION
0 r03 WA
CHECKED BY APPROVED BY Call 811 CITY OF EDMONDS EDMONDS, WASHINGTON
0 two business days 1601 5th Avenue, Suite 1600
TJE TJE before you dig Seattle, WA 98101 DATE: RESUB
DATE 206.622.5822 t MAL, L71 :U/J-
05/27/2015 www.kpff.com 42 4 ............ OVERALL SITE PLAN JUN 0 1 2015 C0601
S C A L E: I!, IST PA ENT
JOB No. :114407 ONAL CITY ENGINEERING DIMS10 i�9 'k RN
NO. DATE BY CHID. APPR. REVISION AS SHOWN N SCHGDL VIED 4ONDS
I 1 .1 1.11,11,111,111,11, 1 DISTRICT FOR PERMIT
Z5 't
U)
Ld
m
C0
(D
fzn
LLJ
-0
0
0
V)
Cn
CD
CD
"L
7
CD
Uj
4
Cl-
r_j
Li
1<
CL
E
0
00
U-)
E
<D
_=3 -
-, X
Cni
Ig
PARENT DRIVE LANE,
.02
AND DROP-OFF.,Z6NE,
F
-ONE-WAY-
12+00 13+00 14+00 15+00 16+00 17+00 18+OD MOD
21+00
10
190 11+0D 19+00
- — --------- f__ +_ i -k— I — — i
106TH AVE. W.
7�7
25' INSIDE RADIUS
-3 PARENT PARKING
PARENT ACCE AT FIRE LANE (TYP) ....
25' INSIDE RADIUS
25' INSIDE RADIUS
AT 171DE' 1 AKIE* TVD ANI) PARKINr.
4
AT FIRE LANE (TYP)
25' OUTSIDE RADIUS -WAY LANES
I'0C '0
ONE
AT FIRE LANE (TYP)
RAIN GARDEN #02
0
NOTES
1. REFER TO SHEET GO.02 FOR GENERAL NOTES.
2. FIRE APPARATUS ACCESS PATHWAY IS 20' MIN WIDTH AND 13' 6" MIN HEIGHT
AT ALL LOCATIONS.
3. FIRE APPARATUS ACCESS LANES PROVIDE 25.0' MIN INTERIOR RADIUS AND
45.0' MIN EXTERIOR RADIUS FOR TURNING.
4. AT THE ADA AND SHUTTLE PICK-UP/DROP-OFF ISLAND IN THE EAST LOT
THERE IS A 20' MINIMUM INSIDE TURNING RADIUS.
ADA AND SHUTTLE TURNING MOVEMENT
C: m
NOO'5f22'E
106TH AVE. W
____1 __j__
0 20 40 80
1 inch = 40 feet
DRAWN BY DESIGNED BY �3 S J 'p EDMONDS SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS SHEET
KWP/TY AJS 0 13 WA APPROVED FOR CONSTRUCTION
CHECKED BY APPROVED BY Call 811 CITY OF EDMONDS EDMONDS, WASHINGTON
0 two business days 1601 5th Avenue, Suite 1600
TJE TJE before you dig Seattle, WA 98101 RESUB
DATE 206.622.5822 DATE:
05/27/2015 lq* www.kpff.com 4 6 is JUN 0 12015 COoO2
PC
S C A L E: �"2� IST BY. FIRE APPARATUS AND SHUTTLE ACCESS PLAN BUILDING DEPARTMENT
JOB No. :114407 IONAL % SCHODL Cirf OF EDMONDS
NO. DATE BY CHD. APPR. REVISION AS SHOWN I DISTRICT FOR PERMIT
_r
41 IZ15; tAN4F' fifWdl&t� 6
iu_ sq -rim mpr.
-3
CITY OF EDMONDS RECOMMENDED CONSTRUCTION SEQUENCE NOTES
1.
SCHEDULE A PRE -CONSTRUCTION MEETING WITH CITY ENGINEERING DIVISION AT 425-771-0220, EXT. 1326.
2.
REVIEW TESC NOTES.
3.
CALL FOR UTILITY LOCATES.
4.
LOCATE INFILTRATION BASINS AND INSTALL CONSTRUCTION FENCE AROUND.
5.
INSTALL ESC MEASURES AND MAINTAIN DUST CONTROL.
6.
HAVE EROSION CONTROL MEASURES INSPECTED BY CITY OF EDMONDS CITY ENGINEERING INSPECTOR. (ALL
C)
TEMPORARY SEDIMENTATION AND EROSION CONTROL MEASURES MUST BE IN PLACE AND INSPECTED PRIOR
TO ANY CONSTRUCTION OR SITE CLEARING. EROSION AND SEDIMENTATION CONTROL PRACTICES AND/OR
m
DEVICES SHALL BE MAINTAINED UNTIL PERMANENT VEGETATION IS ESTABLISHED.)
7.
ROUGH GRADE SITE AS REQUIRED TO INSTALL DRAINAGE FEATURES.
8.
DEMOLISH EXISTING STRUCTURES.
Ln
:3=
rn
m
9.
CLEAR, GRUB & ROUGH GRADE REMAINDER OF SITE. REVEGETATE DISTURBED AREAS NOT SUBJECT TO
ADD111ONAL SURFACE DISTURBANCE IMMEDIATELY AFTER ROUGH GRADING. (OTHER EXPOSED AREAS SHALL
BE STABILIZED PER EROSION CONTROL NOTES BELOW)
10.
INSTALL UTILITIES AND OTHER SITE IMPROVEMENTS.
11.
STABILIZE AND REVEGETATE EN11RE SITE. DISTURBED SOILS SHALL BE COMPOST AMENDED PER CHAPTER 5
OF THE D.O.E. STORMWATER MANAGEMENT MANUAL FOR WESTERN WASHINGTON.
12.
ESTABLISH LANDSCAPING AND PERMANENT VEGETATION. EROSION CONTROL FEATURES CAN BE REMOVED
UPON FINAL SITE STABILIZATION AND APPROVAL. BY CITY INSPECTOR.
TEMPORARY EROSION AND SEDIMENT CONTROL
NOTES
LEGEND:
1. TESC FACILITIES SHALL BE INSPECTED DAILY BY THE
PROPERTY LINE
CONTRACTOR AND MAINTAINED AS NECESSARY OR AS 4.
CONTRACTOR SHALL PROVIDE CONSTRUCTION FENCING AS
7. CONTRACTOR SHALL PREPARE AND SUBMIT A DETAILED
FUTURE INFILTRATION AREA, SEE NOTE 8
DIRECTED BY THE CITY INSPECTOR TO ENSURE CON11NUED
REQUIRED FOR SAFETY AND AS DIRECTED BY THE INSPECTOR.
CONSTRUCTION SEQUENCE PRIOR TO COMMENCING WORK. CITY
c= m= c=
APPROXIMATE LIMITS OF WORK
AND PROPER FUNCTIONING. CONTRACTOR SHALL SPOT CHECK
FENCING SHALL BE PLACED IN A MANNER THAT ALLOWS FULL
OF EDMONDS RECOMMENDED CONSTRUC11ON SEQUENCE NOTES
TESC FACILITIES TO ENSURE SEDIMENT AND POLLUTED RUNOFF
USE OF EXISTING ADJACENT FACILITIES. IN THE EVENT THAT
ARE PROVIDED ON THIS SHEET.
X X X
FILTER FABRIC FENCE
WILL NOT LEAVE THE WORK AREA.
ACCESS TO THOSE FACULTIES CANNOT BE MAINTAINED,
CONTRACTOR SHALL PROVIDE ONE WEEKS WRITTEN N0110E TO
8. INFILTRATION AREAS SHALL BE FULLY PROTECTED FROM ALL
TEMPORARY CHAIN LINK CONSTRUCTION FENCE
2. CATCH BASINS ADJACENT TO THE PROJECT SITE SHALL BE
THE SCHOOL DISTRICT PROJECT MANAGER.
DELETERIOUS MATERIALS (SEDIMENT, CONSTRUCTION DEBRIS,
INSPECTED DAILY BY THE CONTRACTOR. RUNOFF LEAVING THE
STOCKPILE, ETC) AND FROM ANY CONSTRUCTION TRAFFIC
CATCH BASIN PROTECTION
SITE DURING CONSTRUCTION, INCLUDING WATER CARRIED BY 5.
CONTRACTOR SHALL PREVENT ON -SITE EROSION BY
DURING ALL CONSTRUCTION ACTIVITY. PRIOR TO COMMENCING
THE TRUCK TIRES, SHALL BE CLEAN. CONTRACTOR SHALL
STABILIZING ALL SOILS, INCLUDING STOCK PILES THAT ARE
WORK FIELD -LOCATE INFILTRATION FACILITIES (SEE C3.01) AND
TEMPORARY DRAINAGE SWALE FLOW LINE
CLEAN CATCH BASINS AND IMPLEMENT EXTRA SEDIMENTATION
TEMPORARILY EXPOSED.
ERECT CONSTRUCTION FENCE SURROUNDING. ANY
CONTROLS IF NECESSARY AND AS DIRECTED BY THE CITY
UNAUTHORIZED ACTIVITY WITHIN INFILTRATION BASINS
SAND BAG CHECK DAM
INSPECTOR AND THE OWNER. 6.
NO SEDIMENT SHALL BE TRACKED ONTO PAVED SURFACES.
RESULTING IN REDUCED INFILTRATION CAPACITY AS
SEDIMENT SHALL BE REMOVED FROM TRUCKS AND EQUIPMENT
DETERMINED BY THE OWNER SHALL BE FUH Y REPAIRED AT
0
MOBILE 55 GALLON DRUM NTH PUMP
3. SITE INSPECTIONS SHALL BE CONDUCTED BY A CERTIFIED
PRIOR TO LEAVING THE SITE. IN THE EVENT OF FAILURE OF
CONTRACTOR EXPENSE.
EROSION AND SEDIMENT CONTROL LEAD (CESCL) NO SHALL
THE TESC SYSTEM RESULTING IN SEDIMENT BEING TRACKED
TEMPORARY SEDIMENT TANK
BE PRESENT ON SITE OR ON -CALL AT ALL TIMES.
ONTO PAVED SURFACES, THE CONTRACTOR SHALL
9. SEE SHEET C7.01 FOR CITY OF EDMONDS STANDARD DETAILS.
0 10 20 40
6mmmmomw
IMMEDIATELY IMPLEMENT MEASURES TO CORRECT THE
1 inch = 20 feet
SITUATION.
EDMON SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS SHEET
EDMONDS, WASHINGTON
RF.sum
TESC PLAN JUN o 1- 2015 Cl '001
G DEPAR'tMENT
SCHGDL au"Ll""OF EDMONDS
DISTRICT ov FOR PERMIT
8'-0 MIN.,
1,)I-o KAAY nacrrn cm k1Ar%r
NOTES
1. CHAIN LINK FABRIC TO BE MIN. 11 GAUGE, GALVANIZED. NO RUSTED OR
EXCESSIVELY MALFORMED FABRIC.
2. FENCE BASES SHALL BE OF SUFFICIENT WEIGHT AND/OR SPREAD TO
ADEQUATELY SUPPORT EACH PANEL.
3. PANEL —TO —PANEL CONNECTIONS SHALL BE MADE AT A MIN. TWO
LOCATIONS PER CONNECTION UNLESS OTHERWISE APPROVED.
4. PROVIDE CONSTRUCTION WARNING SIGNAGE 50'O.C. ALONG FENCING
INSTALLATION.
TEMPORARY CHAINLINK FENCE DETAIL
NTS
F—
cli
c�
E 1 3
Of
LU
V)
U3
(1)
fm
C)
LLJ
0
W
V)
cn
0)
T
C)
LLJ
cr)
><
Ln
3 E
c'4
(L>
C1.01
C14
2' MIN.
LEVEL BOTTOM
�F:�d I 1:��i I M I 1�1 11.
I I 1�1 I I - I -
SWALE SPACING DEPENDS
ON SLOPE GRADIENT
2:1 MAX. SLOPE
MAINTENANCE STANDARDS:
1. DAMAGE RESULTING FROM RUNOFF OR CONSTRUCTION ACTIVITY SHALL BE
REPAIRED IMMEDIATELY.
2. IF THE FACILITIES DO NOT REGULARLY RETAIN STORM RUNOFF, THE
CAPACITY AND/OR FREQUENCY OF THE DIKES/SWALES SHAH BE INCREASED.
TEMPORARY DRAINAGE SWALE
NTS
DRAWN BY DESIGNED BY
KWP/TY AIS Call 811
CHECKED BY APPROVED BY -two business days
TJE TJE
J[8 before you dig
DATE
05/27/2015
S C A L E:
REVISION JOB No. :114407 AS SHOWN
2
C1.01
1601 5th Avenue, Suite 1600
Seattle, WA 98101
206.622.5822
1cpff www.kpff.com
n1 A nr n^111k le"Mf- A I A ni r% A k A �
LY
N.
CROSS SECTION OF A PROPERLY
INSTALLED SAND BAG BARRIER
t'AKIM MAf%e% At' r%r-^Illnr-r%
PROPER PLACEMENT OF SAND BAG
BARRIER IN A DRAINAGE WAY
*CONTRACTOR SHALL MAINTAIN AND REPLACE
SANG BAGS TO INSURE PROPER EROSION
CONTROL.
�3 S
'10NAL it A%vl
FOR
HIGH
FABRIC
%110N
CITY INSPEC11ON REQUIRED ON ALL
EROSION CONTROL METHODS BEFORE
OTHER WORK CAN BEGIN.
SAND BAG CHECK DAM
FILTRATION SYSTEMS DETAIL
NTS
OVED FOR CONSTRUCTION
CITY OF EDMONDS
DATE:
BY -
CITY ENGINEERING DIVISION
3
C1.01
PROVIDE SOLID COVER
RUNOFF NTH
SEDIMENT
PROVIDE 6" MIN. CLEAN
CRUSHED SURFACING
TOP COURSE
FILTERED RUNOFF
NOTE:
PUMPS SHALL BE SUBMERSIBLE, AND HAVE A MINIMUM
CAPACITY OF 0.22 CFS (98 GPM).
TOP OF DRUM SHALL BE
6" MIN. ABOVE GRADE
DISCHARGE
55 GALLON DRUM NTH
2" DIA. WEEP HOLES
WRAP NTH ALTER FABRIC
WIRE TIES
SUMP PUMP AND MOTOR
CONCRETE BLOCKS
MOBILE 55 GALLON DRUM WITH PUMP
NTS
4
C1.01
SHEET
C1.02
; X 1* 11 � 4 N it I I i
S
U
DEMOLISH PAINT
STRIPING (TYP)
... ...........
62 P)
_SS SS S SS
SS' S
6� 10,
...... DEMOU _T T S SS SS SS
....... SH A PHAL SS
6TH A W. ...... VE ...... PROPERTY LINE(TYP
CL C� ....... 106TH AVE W
. . . . . . . . . . . . . ...
. ... ......... ............
/h A /h
- �L w
DEMOLITION NOTES
09,01=100
MINIM
- - - - loom
am -
pr -------
DEMOLISH CONCRETE
SIDEWALK (TYP) too
DEMOLISH ASPHALT
(TYP)
DEMOLISH CROSSWALK r
MARKINGS (TYP) P. rd" FA,
(�)SAWCUT LINE (TYP) ME
IZ
M= C= N ME! C= Cr
REMOVE ADA SIGN,
----------
----- - --- -
REMO :'LAY
(TYP) S7
AND
GROUND
SECURELY STO E,,"�
E
t "001SH tr1RUD SS SS SS
-ED PLAY STRUCTUR -DTN� I IKICT A
A DDOIDE
TION,
FOR REINSTALLA
C B (TYP)
SEE SHEET C4.01
EMOUSH PAINT(�)
m
STRIPING (TYP)
DEMOLISH DE RB
PROTECT EX LIGHT
POLE POWER
CABINET AND
I�N L A d IRRIGATION
d-
MID) CONTROL BOXES
SAWCUT LINE
(TYP)
N
. . . . . . . . . . . . . .
.. . . . . . . . . ..... .
RELOC I HYDRANT
DEMOLISH CHAINI-0
LA FENCE(TYP)
ASSEM SF��HEET
DEMO SH VERTICAL
C4.01
1 MOVE LIGHT CURB (TYP)
3 RE
SD
DEMOLISH ASPHALT
DEMOLISH 3RASH PAVEMENT
On=
ENCLOSURE EENa
AND BOLLARDS
cm m=
15 REMOVE DUMPqT�S- DEMOLISH 1
�AN WOOD -RAMP STORAGE SHED MOLISH CONCRETE RAMP
11
(TYP)
_GS_
I.
KLrLK IU Z)NtLI UU.U/ rUK UtNtKAL NUItZ).
11.
CONTRACTOR SHALL OBTAIN AND PAY FOR NECESSARY
U5.
DEMOLISH STORAGE SHED, REMOVE DUMPSTER AND WOOD
7.
PROVIDE CONSTRUC11ON FENCING, SIGNAGE, AND BARRIERS TO
PERMITS TO EXECUTE DEMOLITION.
RAMP AND TURN OVER TO DISTRICT FOR FUTURE RELOCATION.
2.
ALL SITE FEATURES SHALL REMAIN AND BE PROTECTED IN
PREVENT UNAUTHORIZED ACCESS INTO DEMOLITION AREA. SEE
PLACE UNLESS NOTED OTHERWISE.
TESC PLAN (SHEET C1.01) FOR APPROXIMATE FENCE
@
ALL WHEEL STOPS AND SIGNAGE WITHIN THE LIMITS OF WORK
CUT AND CAP EX SD LINE AT CATCH BASIN PRIOR TO
LOCATION. CONTRACTOR TO FIELD ADJUST AS NECESSARY
(EXCEPT IN THE PUBLIC RIGHT—OF—WAY) SHALL BE FULLY
REMOVAL.
3.
ALL FEATURES TO REMAIN SHALL BE REPLACED AT THE
BASED ON SITE SPECIFIC CONDITIONS.
REMOVED AND LEGALLY DISPOSED OF OFF —SITE. THESE
CONTRACTOR'S EXPENSE IF DAMAGED DURING DEMOLITION OR
FEATURES MAY BE STORED FOR POSSIBLE REUSE AT
CUT AND CAP EX SD LINE AND GROUT PIPE PENETRATION
CONSTRUCTION ACTIVITIES.
8.
KEEP DUST TO A MINIMUM BY SPRINKLING THE SITE NTH
CONTRACTOR'S OPTION.
WATER--nGHT. PROTECT EX CATCH BASIN IN PLACE.
WATER UNTIL SURFACE IS WET OR AS DIRECTED BY THE
4.
WALK THE SITE WITH OWNER PRIOR TO CONSTRUCTION TO
OWNER.
@
CAREFULLY REMOVE LIGHT POLE (AND ATTACHMENTS) FROM
REMOVE TWO BASKETBALL POLES (NOT SHOWN ON SURVEY)
VERIFY LIMITS OF SITE DISTURBANCE AND EXISTING FEATURES,
POLE BASE AND SECURELY STORE FOR REUSE. DEMOLISH
AND TURN OVER TO DISTRICT FOR FUTURE REUSE.
UTILITIES, AND STRUCTURE TO BE PROTECTED.
9.
IMMEDIATELY REMOVE ALL DEMOLITION DEBRIS FALLING
POLE BASE, CUT AND CAP EXISTING CONDUIT/CABLING, AND
MAKE VERTICAL SAWCUTS BETWEEN ALL EXISTING PAVEMENT
OUTSIDE THE LIMIT OF WORK.
PREPARE FOR EXTENSION PER IL1.01.
TO REMAIN AND THE PORTION TO BE REMOVED. PROTECT IN
10.
DISPOSE OF EXCESS DEMOLITION MATERIAL OFF —SITE IN A
TREES TO BE REMOVED SHALL BE FULLY REMOVED AND
PLACE PAVEMENT OUTSIDE SAWCUT LINE.
SAFE AND LEGAL MANNER AT NO EXPENSE TO THE OWNER.
LEGALLY DISPOSED OF OFF —SITE. STUMPS SHALL BE REMOVED
ALL PAVEMENT MARKINGS WITHIN THE LIMITS OF WORK SHALL
TO 3 FEET BELOW FINISHED GRADE ELEVATION AND
BE FULLY REMOVED THROUGH EITHER GRINDING OR BEAD
BACKFILLED NTH STRUCTURAL FILL.
BLASTING.
DRAWN BY DESIGNED BY
KWP/TY AJS
0 WA
CHECKED BY AP OVED BY Call 81
0 - 1, _1 - two business days 1601 5th Avenue, Suite 1600
TJE TJE before you dig Seattle, WA 98101 CA
DATE 206.622.5822
05/27/2015 www.kpff.com 4 64
S C A L E: IST
NO. DATE BY tCHD. I APPR. I REVISION JOB No. :114407 AS SHOWN IONAL %
APPROVED FOR CONSTRUCTION
CITY OF EDMONDS
DATE:
BY. / . ............ 0`�'&YM p Jj
`�?Y ENGINEERING DIVISION ' I
C")
m
m
LEGEND:
PROPERTY LINE 0 DEMOLISH BOLLARD/POST
M=
APPROXIMATE LIMITS OF WORK
DEMOLISH ASPHALT
ff DEMOLISH UTILITY LINE
DEMOLISH CONCRETE SIDEWALK
X x DEMOLISH CHAINLINK FENCE �7m
77 7 7 7 7)
— — — — — — — — — — SAWCUT LINE DEMOLISH PLAYGROUND AND PLAY STRUCTURES
DEMOLISH CURB
........................... DEMOLISH PAINT STRIPE DEMOLISH CROSSWALK MARKINGS
DEMOLISH TREE
DEMOLISH LANDSCAPE
DEMOLISH CATCH BASIN/ AREA DRAIN 0 10 20 40
DEMOLISH STRUCTURE Immmmommil
SALVAGE SIGN AND LIGHT POLE 1 1 inch = 20 feet
EDMONDI SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS
In EDMONDS, WASHINGTON
SCHODL
DISTRICT
DEMOLITION PLAN
JUN 0 12015
BUILDING DEPARTMENT
CITY OF EDMONDS
SHEET
C2e0l
FOR PERMIT
S!
Lp /y\ EM G 20
0
B to 70
EXIS B w
M_f��DJU� se B ERIDE ED
A T ME RATE M DI ;J;� --i - RADI
RI -285.50 1// MODULAR BLCK ALL
16t0o P 1 00 1 +00 20+00
PER COE.STD E8 It �7kR t, .3 21 0
C7.02 i �_
16+ W 3.0
.1.2
2 (1319.9 M, 131 .62 P) SEE
EA Z)W
ADJUS FRA
S S SS SS SS _SS ss- S S 4�. S ss-- Zl� S 4\7F 21 tO
SS S ss- SS SS SO S SS
6TH A PR�OPERTY LINE 106TH AVENUE Y N\
- - - - - - - CD CD CD LEE
U
King 1 !P:F fil QHPT &
__T_ " : -
TI HPT T
-OHPT
HO
EX TEE CONNEC11ON
on, TO EX 18" SD TO
11MM REMAIN
WWA
IIIIIIIIIIIIINA
Owy................ I .. Ra
1 m awil
WA
MA
A dw
---- ------- vy7-
I! TC 281& 1 1 --- - -------
III / I � �Ll::' D'
5. i4 TC 284.40� '3 _WAIN� DEN #01('002�
85.14(EX) I BC 5. 6(EX V 14��Cll 15+00
I I 9C 283.90 EX SLOTTEFFO.Of,--- 500 SF B Om �0.03� (-+- I I
,A i ____ . -- - f - AREA SS SS SS
't2 R SS SS
(IS 3. 1,448. 9 61
U) A .
cis YD#01
S Ep SDCB 0 W/ SOLID LID
RIM= 3.30 RIM=281.70
FE
ZE _��3 IE=281.63 IE=279.39± 4 -,- '7' rT-
m FIELD LOCATE ON
0 EX SD
177
I P-1 -
01
ol 8�1
d
d -JL-
d
d 00 *E
C-)
,4u 8.3 4A
96 Ly 00 C 00
e9
.......... TV CN
e� -0 m
TC :2
EX
_j & > RIM�'86.58
U/
1p C% Cn
- - - - - - - - - - - - - - - - - - s A m
11 - - --- I z879 m
3, STA 15+83.7 1 25 1' T IR? . - - I - I SD
RELOCATE A E H R N 286.7 E
.7.0 ;,,O_- ---TC-284,50-
ASSEMBLY P R E STD .1.
BC 284.00(EX)
SEE NOTE 1
284.60
- - - - - - - - - - - 0 lip.
10(EX) I "p C,
r=
CD PEDESTRIAN ISLAND GRADING
C� SCALE: 1 10' C3.01
N-)
GRADING AND DRAINAGE NOTES LEGEND:
Cn �,
W C-D
5�-E� 281 EXISTING CONTOUR LINE
CD 1. SEE SHEET GO.02 FOR ADDITIONAL NOTES. 6. CONTRACTOR SHALL RAISE, LOWER ALL EXISTING UTILITY 10. REFER TO COE STD E4.2, DETAIL 1 ON SHEET C7.02, FOR 15. SWALE AND INFILTRATION ON EAST SIDE OF ACCESS ROAD 4( FIRE HYDRANT ASSEMBLY (3/C7.02)
Uj TYPICAL STORM DRAIN TRENCH SECTION. IS A REPLACE -IN -KIND OF THE EXISTING SYSTEM. THIS
STRUCTURE RIMS/GRATES TO FINISHED GRADE UNLESS
2. SEE SHEET CO.01 FOR MASTER SITE PLAN AND OVERALL NOTED OTHERWISE. FACILITY PROVIDES STORMWATER MITIGATION FOR THE 281 PROPOSED CONTOUR LINE 04 GATE VALVE
CD
Uj SITE CONTROL LAYOUT. 11. ALL STORM DRAIN CATCH BASINS SHALL BE TYPE 1 CATCH EXISTING PLAY FIELD TO THE EAST. -
=: -SD- STORM DRAIN LINE
7. STORM DRAIN STRUCTURES SHALL BE PLACED SO THAT BASINS PER DETAIL 4 ON SHEET C3.02. TEE
>< 16. ALL LOCATIONS OF STORM DRAIN AND UTILITY STRUCTURES
3. INSTALL A 90-DEGREE DOWNTURN ELBOW AT THE OUTLET RIMS/GRATES ARE PARALLEL TO FINISHED GRADES.
Cn
V) PIPE FOR OIL CONTROL IN ALL CATCH BASINS, NTH THE 12. SEE SECTION A ON SHEET C3.03 FOR TYPICAL RAIN ARE TO CENTER OF THE STRUCTURE. m YARD DRAIN
bi EXCEP11ON OF THOSE LOCATED IN RAIN GARDENS. 8. ALL NEW PAVEMENT SHALL MEET AND MATCH EXISTING GARDEN DETAIL.
C:1 =
Cn 17. FELOCATED FIRE HYDRANT SHALL BE INSTALLED AS A mm TYPE 1 CATCH BASIN (7/C3.02)
>< GRADES.
4. VERIFY ALL EXISTING UTILITY LOCATIONS AND DEPTHS PRIOR 13. INFILTRATION AREAS SHALL BE FULLY PROTECTED FROM CUT -IN TO THE EXISTING WATER MAIN.
m M loo- FLOW DIRECTION
TO BEGINNING CONSTRUCTION. INSTALL POLYETHYLENE 9. FIELD VERIFY SOIL CHARACTERISTICS BELOW RAIN GARDENS ALL DELETERIOUS MATERIALS (SEDIMENT, CONSTRUCTION
(.0
N-) PLASTIC FOAM AT UTILITY CROSSINGS IF CLEARANCE IS DURING EXCAVATION AS DESCRIBED IN THE GEOTECHNICAL DEBRIS, STOCKPILE, ETC) AND FROM ANY CONSTRUCT10N 18. NOTE TO REVIEWER: SEE SHEET C3.02 FOR IMPERVIOUS
XXX.XX
LESS THAN 6 INCHES. MEMO. UNDISTURBED SOIL SUBGRADE SHOULD BE OBSERVED TRAFFIC DURING ALL CONSTRUCTION ACTIVITY. COORDINATE SURFACE SUMMARY TABLE. SPOT ELEVATION
BY A QUALIFIED GEOTECHNICAL ENGINEER PRIOR TO WITH NOTE 8 ON SHEET C1.01.
19. IIAPERVIOUS SURFACE AREA CHART PER CITY OF EDMONDS 0
5. VERIFY ALL EXIS11NG GRADES PRIOR TO CONSTRUCTION CONSTRUCTION. IF SOIL SUBGRADE IS COMPACTED DURING STORM DRAIN CLEANOUT (SDCO) (5/C3.02)
CONSTRUCTION OR IS NOT CONSISTENT NTH THE PROPOSED 14. CENTER BLOCK WALL BETWEEN ADA RAMP AND PARKING
ACTNTIES. CONTRACTOR SHALL NOTIFY ENGINEER OF ANY HANDOUT E72 PROVIDED IN DETAIL 7/C3.02. THIS
Uj
........................
V) DISCREPANCIES IN EXISTING GRADE ELEVATIONS. DESIGN, EXCAVATE UNSUITABLE SOILS AND REPLACE WITH LOT. WALL SHALL BE 20' LONG (MIN), 30" HIGH (MAX), 114FORMAIION IS PROVIDED FOR PERMIT PURPOSES ONLY RIDGE LINE 0 10 20 40
L- I i
SELECT FILL MATERIAL AS DESCRIBED IN THE AND 50SF FACE. AND IS NOT TO BE RELIED UPON FOR BIDDING OR -
1 inch 20 feet
GEOTECHNICAL MEMO. CONSTRUCTION PURPOSES. SAWCUT
ck�
V)
I
DRAWN BY DESIGNED BY
Lr) KWP/TY AJS
13 WA
Call 8
E Uj CHECKED BY APPROVED BY
0 = two business days 1601 5th Avenue, Suite 1600
TJE TJE before you dig Seattle, WA 98101
DATE 206.622.5822
LO www.kpff.com
E; E 05/27/2015 76
A.
S C A L E: IST
3 ORAL
DATE BY CHID. APPR. JOB No. :114407 AS SHOWN
REVISION
S!
EDMONDI SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY' IMPROVEMENTS SHEET
EDMONDS, WASHINGTON
jqESUS
GRADING, DRAINAGE, AND UTILITY PLAN jUNI 0 1 2015 C101
SCHODL 0 DEPARWENT
OF F
DISTRICT L)MONDS FOR PERMIT
><
W4L -To Dj2ft4kdjrC_ W09T
1#9164' ft-S-0 1061AW4f IAW 04
15)(j&jjAj& SVSICA4.
CONCRETE CUR[
PER PLAN (TYP
CONCRETE SIDEWALK
PER PLAN
W4
COVER
WIRE MESH REINFORCEMENET 6x6
.OxW4.0 (4 GAUGE), 1/2-MINIMU�
I
c I C � Tom��
Uj
Co
C-) C_�
CL
<
:: _j
$ �11 0-
I R
LO
24"
PLANUVIVIV, vviff
DUMMY JOINT WITH
3/16"xl-1/2" JOINT
MATERIAL (TYP)
NOTES:
1. PIPE ENDS SHALL BE FLUSH WITH
FACE OF CURB.
2. PIPE INVERTS SHALL MATCH CURB
GUTTER LINE OR TOP OF PAVEMENT.
12 6"
- -
(TYP) 3. WIRE MESH SHALL CONFORM TO
WSDOT STD SPEC 9-07.7
SECTION A
STORM DRAIN UNDER SIDEWALK DETAIL
C)
m
450 BEND
PLUG
PLAN INVERT
ELEVATION
0 0.0,
0 0
NTS C3.01
THREADED CLEAN -OUT
4" OR 6" PER PLAN
WYE
110-010,
.0.
STORM DRAIN CLEANOUT
NTS
PERFORATED DRAIN PIPE
PER PLAN
5
C3.01
ME
OBSERVATION PORT
4" PVC SCH. 40 PIPE
W/REMOVABLE CAP AT
END OF PERF. PIPE
A
2.84'
SEED TOPSOIL
WITH FIELD MIX
TOPSOIL
GEOTEXTILE SLOPE TO Q DRAIN
_1V:3H MAX.
4" SLOTTED DRAIN
PIPE, LEVEL
GRAVEL BACKFILL
FOR DRAINS
NOTES:.
DETAIL REFERENCED FROM RECORD DRAWINGS OF PLAYFIELD
RENOVATION (2000). REPLACE SWALE AND INFILTRATION TRENCH
IN -KIND WITH EXISTING SYSTEM AT LOCA11ONS INDICATED ON PLAN.
SWALE AND INFILTRATION TRENCH
NTS
6' MIN.
'w
PC
PLAN
C*-A
2
C3.01
12"
6" CONCRETE VERTICAL CURB
PER COE STD E2.1 0
t
4-.
-4.
Af.
/Z1
.
Al
CURB DROP SHALL BE FWSH NTH
CURB FLOW LINE TO PERMIT DRAINAGE
INTO RAIN GARDEN
NOTCHED CURB
ASPHALT DRIVE LANE QUARRY SPALL SPLASH PAD
FROM CURB TO BOTTOM OF
RAIN GARDEN (12- WIDTH,
4- DEPTH)
1 0-000.
.00 1000.
0
"0.
* C,
0
1
I
3 7
CONCRETE VERTICAL CURB-J
PER COE STD E2.1 0
UNCOMPACTED RAIN GARDEN
SOIL
2. PIPE SHALL BE PER PROJECT SPECIFICATIONS.
NOTCHED CURB AND SPLASH PAD
STORM DRAIN OUTLET PROTECTION
NTS
-6
C3.03
NTS
SECTION B-B
3
C3.03
(1) #3 BAR EACH HOOF
#3 BAR EACH CORNEI
#3 BAR EACH SIDE
FRAME, VANED GRATE AND
SOLID LID
2 4", 6", 12"
)---OR 24" RISER
1ICAL KNOCKOUT
2" MIN. WALL THICKNESS
lr%., WAR EACH WAY
TYPE 1 CATCH BASIN r4_'��
NTS
C3.01
IMPERVIOUS SURFACE SUMMARY
NON -REGULATED
32,670 SF (0.75 AC) EXIS_�ffl IMPERVIOUS NOT DISTURBED
EXEMPT
REGULATED
REPLACED
0 SF
14,470 SF (0.33 AC)
NEW (POST 1977)
-> -> -> ->
+
14,715 SF (0.34
TOTAL REGULATED IMPERVIOUS AREA
(MITIGATION REQUIRED IF IN EXCESS OF 2000 SF)
.,2 W5 SF (0.67 AC)
Iss-sp 1
TOTAL AREA MITIGATED BY EX STORMWATER MANAGEMENT SYSTEMS
0 SF (0 AC)
REGULATED AREA NOT YET MITIGATED
:��SF (0.67 AC)
AREA PROPOSED TO BE MITIGATED BY LID TECHNIQUES
1
1 (0.67 AC)
AREA PROPOSED TO BE MITIGATED BY CONVENTIONAL SWM TECHNIQUES1
-
"0' SF (0 AC)
NOTES:.
1. THIS TABLE IS INTENDED TO IDENTIFY THE EXISTING (UNDISTURBED) AND PROPOSED
(NEW+REPLACED) IMPERVIOUS SURFACE AREAS FOR THE SITE, AS REQUIRED BY
CITY OF EDMONDS HANDOUT #E72.
2. AREAS IN THIS TABLE ARE ESTIMATED FROM THE EXTENT OF SITE IMPROVEMENTS
SHOWN ON SHEET C3.01.
3. AREAS ARE APPROXIMATE AND ARE SHOWN FOR PERMITTING PURPOSES ONLY.
IMPERVIOUS SURFACE SUMMARY CHART r7-
NTS C3.01
DRAM BY DESIGNED BY 13 S j EDMONDS SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS SHEET
KWP/TY AJS 61 APPROVED FOR CONSTRUCTION
CHECKED BY APPROVED BY 0 call 811 13 CITY OF EDMONDS EDMONDS, WASHINGTON
0 two business days 1601 Sth Avenue, Suite 1600
TJE TJE before yo Seattle, WA 98101 DATE: =ZUN
DATE 206.622.5822 JUN 0 12015
05/27/2015 www.kpff.com 42 4 By- GRADING AND DRAINAGE DETAILS BUILDING DEPARTIMENT C3*02
S C A L E: IST 01'n OF EDMONDS
REVISION JOB No. :114407 AS SHOWN SCH(OL
DATE BY CHD. APPR. I 11DISTRICT FOR PERMIT
Uj
C.)
fn
E
W
><
co
cm
C..)
X
G -4-
-,I- C14
'-t
c"
Im
0')
cf)
Uj
x
zz
c'
Uf
E Uj
cn- =
C) cn
cli
LO b3
LZ
GRADING ENLARGEMENT
3koMLL; I = IV
1 —
C3.01
"b
( 6 STORM DRAIN
3.02 OUTLET
PROTECTION
p
SD —SD
......... . .
I-
to
r5
(3) SDCO �0.02/
11*�
28.7
BOTTOM
OF SLOPE
TOP OF SLOPE -
00
CN
BOTTOM
ELEVATION
281.08
i5—CF 6"' D I A
SLOTTED STORM PIPE
@ 0.07o, 7.5' ON
CENTER
I ki wo Ell Oki 111 lk .01"
SCALE: 1"=10'
RAIN GARDEN —
PLANTING PER
LANDSCAPE PLANS
PAVEMENT OR
LANDSCAPE SURFACE
PER PLAN (TYP)
3/4" WASHED -
SANDY GRAVEL
1-1/2" WASHED
GRAVEL
UNCOMPACTED NATIVE
SUBGRADE
2
C3.01
4`I I ' "
3) 18 LF 6 DIA
)ERFORATED STORM PIPE
@ 0 7.5',,.\6N CENTER
r FF
ITORM DRAIN
OUTLET
PROTECTION
ma
m
1:rm
-LIZTOP OF SLOPE
BOTTOM OF
SLOPE
-
25.0' . I )
BOTTOM ELEVATION
276.00
r5-'*� (3) SDCO NOTCHED CURB
Is , �-1 2 AND SPLASH PAD� �.02
RAIN GARDEN
SCALE: 1"=10'
TYPE 1 CATCH BASIN W/ SQUARE
BEEHIVE DRAINAGE GRATE (BEYOND)
PER PLAN
nim ni AM
0 UIA Z)LU I I W Z) I UKM UKAIN
PIPE PER PLAN
ITrIUAL KAIN UAKAN �)LUIIUN ( A
E3.01
NTS
rIT01
18" RAIN GARDEN
SOIL MIX
INVERT OF OUTLET PIPE AT
BOTTOM ELEVATION OF RAIN
GARDEN SOIL
WRAP WALLS IN WOVEN
GEOTEXTILE FABRIC
DRAWN BY DESIGNED BY S j EDMONDI SHEET
KWP/TY AJS J, SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS
0 Call 811 WA APPROVED FOR CONSTRUCTION
,CHECKED BY APPROVED BY 0 CITY OF EDMONDS EDMONDS, WASHINGTON
jg,- two business days 1601 5th Avenue, Suite 1600
jj r in
TJ TJE before you dig Seattle, WA 98101
DATE 206.622.5822 DATE: RESUB
05/27/2015 www.kpff.com 4 GRADING AND DRAINAGE ENLARGEMENTS JUN 18 2015 C3.03
S C A L E: lq3ff IT BY: — Tlg���nZd - BUIL
ON LITY ENWEERINg DFASION SCHML AND DETAILS TDy1N0QFDEEDP M NT
NO. JOB No. :114407 MAORT
ND!
DATE BY CHID. APPR. REVISION AS SHOWN cl
I 1 11 D I ST R I CT FOR PERMIT
9
C)
I
Of
LU
2�
U)
(D
LLJ
0
V)
r')
V)
CD
C-D
w
LLJ
Cf)
LLJ
E
0
CD
><
Ln
3 E
C,4
C)
-7-5*1r+516.63, 41.06' RT
16+00 PARKING LOT CONTROL POINT 17+00 18+00
SLL NOIUi 12 660.16 IREF.3 (660.23 M)
[�V�(1319.9 =,�V2
1319.95 REF2 STA 16+32.49, 13.25' �T AND 13.
r 9 B
6TH A AND GUTTER PERCOE
Y69 C7 0
tZ.0_ANU_A3r_l1ALL_WA1 K-RA T .. .. .. .. ..
P
COE:VZE2.12 (MATCH EX cTA 17+07.4 :13.02' RT/1,
END CURB AND GUTTER AND
'7
AS LT -WALKWAY_ (MATCH
�X r8
RAMP PAVING ENLARGEMENT
�C4.02�
LANDSCAPE AREAS (TYP)
S1W t6F47.89, 8M RT
< ..... .......
. . . . . . . . . . ..... END PEDESTRIAN HANDRAIL
/ "X ' / 7 '- 7 7 7 7 7
/_5 VERTICAL CURB PER
7-J
!A
C) A
"M - 2F - M2.
C)
C5 x
. . . . . . . . . . . . . . . . . . . -------------- . . . . . . .
-H
----------
4 -
4
A4
U I
C C4
4 STA 17+50.1 73.87' RT.
---BD VER11CAI CURB
VEftCAt----"
ASPHALT PAVING
T�P-E-RDOW
C5)-
CURB WING A" 1: 1
.777.
CIZ
-------------
A, I
IN
PROPERTY LINE (TYP)
47W, P9.3
0
299:95--C-
'A
STA 19+69.92, V.8
END VERTICALAURB
(MATCH EX)//
FATCH EX
T
4 SAWCUI
21+00
1
106TH AVENUE
CD
//1 hy
STA 21+16.90, 88.92' RT -
TAPER DOWN VER11CAL CURB
WING AT 1: 12 (MATCH EX
ASPHALT CHANNEL)
8 _�DRIVEWAY PER COE
�STD E2.27
-01
STA 20+80.39, 125.82' RT
TAPER UP VERTICAL CURB
AT 1: 1
A A�d . .. / . . 11 . I . . . --- �_-' . /.'. * / . ... */ '. */ '.' */ '' */ " */ ' * I/ ' / " -/ , , '/ , / ..' I- I
�C7.01/COE STD E2.10 (TYP) STA 16+7383 107.56 RT ..... .
............. .. . 1 VER11CAL CURB
A
VER11CAL CUROCONTROL PONT
CEMENT CONCRETE lop-, . -7
SEE NOTE 14
SIDEW
TAPER DOWN VER11CAL
STA 20+68.39, 125.82' RT
K'3 7-7 ALK
ALK PER COE
STA 17+50.00, 143.27' RT STA 18+91.39, 101.60' RT
A 116+95.
\C7'01� STD E2.13 CURB AT1:1
VERTICAL CURB CONTROL POINT
PER COE STD E2.13
VERTICAL CURB CONTROL POI STA 21+16.65
i 75, RT- 140.91' RT
STA 17+93.37, 107.34' RT
STA 15+96.75, 107.56' RT VERTICAL WOOD CHIPS PER VER11CAL CURB CONTROL POINT STA 18+81.56, 102.17' RT
KO'4 END VER11CAL CURB
BEGIN VERTICAL CURB PER CONTROL POINT LANDSCAPE PLANS. ASPHALT PAVING TAPER DOWN VER11CAL CURB WING AT
VERTICAL CURB CONTROL POINT (TYP)
STA 17+83.55, 107.90' RT
A
2
X
VERTICAL CURB CONTROL POINT
COE STD E2.10 (MATCH EX) \C4.02/ 1: 12 (MATCH EX ASPHALT CHANNEL)
+ .97, 1
-nr 65.82' RT
STA 15+80.48, 168.87' RT - 6" VERTIUAL CU B
r1f-^L1 %1rn'nf%A ^i inn nrn ADNIKIn rKin i/pp -Ai mpp WATr� ry)
_j
OLVIN Vr_R11%j/iL WREJ FLR rr Ur1k1%%jV11Lj -------
- - - - -------------------- ----
PRO
LANDSCAPEISLAND 3TA 17+07.96 152 76
COE STD E2.10 (MATCH EX) -41 R STA 17+34.31, 157.06' RT
6 - 14+00
PER COE STD E2.1 0 15+00
CO* REINSTALL PLAY GROUND 106TH A,
VEfidL CGR NTRE L
(TYP) NUE
NT___ EQUIPMENT, SEE DETAIL 2 ON N01'06'38"E
D NZLAND_WmG SHEET C4.03 FOR FOUNDATION
PE ESTR
STA 16+94.559
C4.01 A STA 17+08.08, 165.81' RT LANDSCAPE (TYP) A31PHALT PAVING
N� INFORMATION.
178.38' RT BEGIN VER11CAL CURB PER
CEMENT CONCRET15 SI EWALK PER END EXTRUDED COE STD E2.10 (MATCH EX)
COE STD E213 Fo! � HUTTLE AND
CURB 2' WIDE DETECTABLE?e7".'N
ADA PICK-UP/DRd/. ]:PPJ- FF
WARNING SURFACE C7.01�
0 CUR FLUSH WITH
RT /*
�,,�STA 14+81. 06' RT X
�C4.03� SU !OUN
G
rT� ffy/,
G R"A
F ,,,,%R0G LOT 0 OL
EXTRUDED CURB PER FU
P0
R8 COE STD E2.7 �C7.01�
X
C
25.0' 'w t 150; 65.0'
r
STA 15+70.14, 237.90' RT
BEGIN VERTICAL CURB PER
COE STD E2.1 0 (MATCH EX)
VERTI&L''66-RB CONTROL POINT
STA 16+33.05, 2
VERTICAL CURB (
' RT
OL POINT
rKtUAbl WHttL Z)lUr 'f.m' 00
(TYP OF 11) C4.02/ BEGIN VE L CU
PER COE STD E2.1 0
31M 10-rJ4.JJ, 4't4.J/ Al kMAIUH LA)
SAWCUT (TYP)
PARKING LOT CONTROL OINT
STA 16+07.30, 248.00' RT
END PEDESTRIAN HANDRAIL e'00_4�
ASPHALT PA NU I YF - - - - - - - M
C4.02
L - -Ij . . . . . .
6" VERTICAL CURB AROUND I V RTICAL C
LANDSCAPEISLAND PER
E.".'J" C:)E[7 E2.1 TYP R1
6
A 1. �-- . i, COE STD E2.1 0
A
q n'
4�
'X
'0z
m
m
c)
00
C)
4
SEE
NOTES
12 AND
13
N.)
f
M
C)
(j)
Co F-
C,
CD M
4- z
)
CA
p
!
mcj)
"J CA
0.0 STA 16+07.30, 151.67' RT
000
0 BEGIN PEDESTRIAN ANDRAIL le'4
PER COE STD E8.8. �C7.02/
oe R3
--- -------------------
1.5' EDE DETECTABLE 7
!?0 WARNING SURFACE
C7.01
fTYP OF 3) L
'CEYENT CONC TE
STA 16+94.55, 271.89' RT
STA 16+64.55, 28 .39' RT 3 BEGIN EXTRUDED CURB PER I P 4 TA 5+09.
EGIN PEDE-STRIA�
COE STD E2.7 ru
CONCRETE RAMP 4.02 7.02 PEDESTRIAN ISLAND PAVING
CENTERED ON DR AISLE MR POE STD E8 1- T_ ';(A I P 1 1 o'
1
C4.01
PAVING NOTES
LEGEND:
1.
SEE SHEET GO.02 FOR GENERAL NOTES.
9.
SEE SHEET IL1.01 FOR LIGHT LOCATIONS.
PROPERTY LINE
................ ............
............
... =.*.,.,.,.,.,.*.,.*.*.*::.*.*.,=.*.'.*.*.'.'.=......:.
.........................
ASPHALT PAVEMENT (4/C4.02)
2.
SEE SHEET CO.01 FOR MASTER SITE PLAN AND OVERALL SITE CONTROL
10.
SEE SHEET C7.01 FOR COE STD DETAILS.
APPROXIMATE LIMIT OF CONSTRUCTION
LAYOUT.
A
CONCRETE SIDEWALK (3/C7.01)
11.
LOCATION OF PLAY GROUND EQUIPMENT IS AT CENTER OF STRUCTURE.
EXTRUDED CURB (4/C7.01)
3.
SEE SHEET 1-1.01 FOR LANDSCAPE PLANTINGS AREAS.
12.
A SEPARATE RIGHT-OF-WAY CONSTRUCTION PERMIT IS REQUIRED FOR ALL
VER11CAL CURB (5/C7.01)
LANDSCAPE AREAS (SEE LANDSCAPE PLANS)
4.
SEE SHEET C5.01 FOR HORIZONTAL CONTROL TABLES.
WORK WITHIN THE CITY RIGHT-OF-WAY.
5.
ALL STATIONS AND DIMENSIONS ARE TO BOTTOM FACE OF CURB UNLESS
13.
CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL PLAN FOR ALL WORK
CURB WHEEL STOP (2/C4.02)
OTHERWISE NOTED.
WITHIN THE RIGHT-OF-WAY TO THE CITY OF EDMONDS PRIOR TO
- - - - - - -
- SAWCUT LINE
CONSTRUCTION.
6.
ALL CURB LINES ARE PARALI EL OR PERPENDICULAR TO THE CONSTRUCTION
CHAIN LINK FENCE
BASELINE UNLESS NOTED OTHERWISE.
14.
CURB DROP IS INTENDED FOR MAINTENANCE ACCESS TO FIELD. PROVIDE
SMOOTH TRANSITION FROM TOP OF CURB TO LAWN FOR THE EXTENT OF THE
HANDRAIL
7.
ALL CURB RADII ARE 3.0' UNLESS OTHERWISE NOTED.
CURB DROP. COORDINATE CURB DROP WITH INSTALLA11ON OF CHAIN LINK
GATE PER SHEET L1.01 AND DETAIL 2 SHEET 1-1.02.
CURB RAMP TYPE
0 10 20 40
8.
SEE SHEET C5.01 FOR STRIPING PLAN.
I inch = 20 feet
pow- To AOW41.1 mAl 'ptow 101z
-r16p_. 4ff, ftjWSri a.5ffiW1 aV Mf 4010iV S/AlFi5r,
DRAWN BY DESIGNED BY EDMONDS SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS SHEET
KWP/TY AJS A APPROVED FOR CONSTRUCTION
ie WA
5) ' V
Call 811 V;e CITY OF EDMONDS EDMONDS, WASHINGTON
CHECKED BY APPROVED BY 0 two business days My"
1601 5th Avenue, Suite 1600 Um
TJE TJE before you dig Seattle, WA 98101 DATE: lult 4411z' RES
DATE 206.622.5822 4 JUN 0 1. 2015
05/27/2015 1 www.kpff.com 42 64 Byr�ffl& PAVING PUN C4*01
S C A L E: IST llundz BUILDING DEPAVII14EWI
NO. DATE BY CHD. APPR. REVISION JOB No. :114407 AS SHOWN IONAL el I Y LNGINFERING DI ION SCHODL 01-ry OF F-DM,,ND6
. . . . . ............. .... 13 1 S T R I C T. FOR PERMIT
CN
cn
4=1
<
E
lu
w
-0
a
0
cn
cn
(n
,!: ED
Tz:
uj
cn
r"i I
En
E w
>1<
ON GRADE
EXIS11NG
FENCE
1/2' DIA SCREW ANCHOR,
(1) EA CORNER
EXISTING
PLAY GROUND-----,
20'x8' STORAGE SHED
-CENTERED ON SLAB
STORAGE SHED
CENTERED ON
SLAB
6" CLR
ALL AROUND
6" CONCRETE SLAB
ON GRADE NTH
SECTION A -A #4 0 12- OC EACH WAY
CENTERED IN SLAB
NOTES:
1. CONCRETE SHALL BE CLASS 3-3000 PSI.
2. LOCATION OF SLAB AND STORAGE SHED IS AT CENTER OF STRUCTURE.
STORAGE SHED ENLARGEMENT
NTS
RAMP LANDING 5
SEE NOTE 3
1/2" EXPANSION CURB RAMP CURB
JOINT (TYP) MAX
CURB RAMP CURB Q Q 00000
�)OOOOOOO
0000000(
1) r) r) n n n n n
DETECTABLE
WARNING
SURFACE :z
RAMP LANDING,
SEE NOTE 3
PLAN
CO.01
CURB RAMP CURB 1 V. 12H SLOPE (MAX) GRADE BREAK (TYP)
CONCRETE SIDEWALK
TOP OF PAVEMENT
_ _ _ _ =�_f /I i.
CURB RAMP
DETECTABLE WARNING SURFACE
SECTION A -A
NOTES:
1 . SEE COE STD E2.16 (DETAIL 6/C7.01) FOR GENERAL CURB RAMP NOTES.
2. SEE COE STD E2.23 (DETAIL 7/C7.01) FOR DETECTABLE WARNING SURFACE DETAILS.
3. RAMP LANDINGS SHALL BE 2.0% MAX IN ANY DIRECTION.
4. SEE SHEETS C3.01 AND C3.03 FOR RAMP GRADING INFORMATION.
MODIFIED CURB RAMPS R1.R8-,R9 t/ �5
NO. DATE BY CHD. APPR.
NTS
REVISION
C4.01
- - - - -- - - - - - - - - - - - - - - - -
'00 #3 BARS (2)
p
1.0' 1.0' 2.0 2" CLEAR (TYP.)
ELEVATION
61
9-- MAX.
6" MIN. PLAN
PRECAST CURB BUMPER
5"
2 1/2
2 1/2 RECESS BAR 1"
AND PLACE
ATTACH NTH NON -SHRINK
#3 B RS (2) #6 BAR (2) GROUT AROUND
co BAR TO FILL
10" MAX. RECESS.
8" MIN.
ATTACHMENT DETAIL
NOTES
1. THE NON -SHRINK GROUT USED TO ATTACH THE PRECAST CURB SHALL CONSIST OF 3:1
SAND AND CEMENT. GROUT TO A DEPTH OF 1" FROM THE TOP OF THE BUMPER.
2. LOCATIONS FOR WEEPHOLES, AND V-SLOTS SHALL BE IDENTIFIED ON THE DELIVERY
ORDER DRAWINGS.
3. CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS.
RAMP LANDING,
SEE NOTE 3
VERTICAL CURB
A7
DETECTABLE WARNING
SURFACE
PRECAST WHEEL STOP
NTS
CURB RAMP CURB
1" RADIUS
PLAN
CURB RAMP CURB
RAMP LANDING
VERTICAL CURB 15-0" (MIN) LANDIN 1V*.12H SLOPE (MAX)
CURB RAMP
SECTION A -A
RAMP LANDING,
SEE NOTE 3
1/2' EXPANSION
JOINT (TYP)
CONCRETE SIDEWALK
GRADE BREAK (TYP)
NOTES:
1. SEE COE STD E2.16 (DETAIL 6/C7.01) FOR GENERAL CURB RAMP NOTES.
2. SEE COE STD E2.23 (DETAIL 7/C7.01) FOR DETECTABLE WARNING SURFACE DETAILS.
3. RAMP LANDINGS SHALL BE 2.0% MAX IN ANY DIRECTION.
4. SEE SHEETS C3.01 AND C3.03 FOR RAMP GRADING INFORMATION.
MODIFIED CURB RAMP R7
1 "ABOVE -
PAVEMENT
91
< '110-10
NOTES:
1. CONCRETE SHALL BE CLASS 3 - 3000 PSI.
2. DRIVEWAY SHALL HAVE A FULL DEPTH EXPANSION JOINT NEAR
THE CENTERLINE OF DRIVEWAY.
3. DRIVEWAY APRON SHALL BE A MINIMUM OF 6" THICK AND
SHALL BE PLACED ON 2" OF 5/8" CSTC AND COMPACTED
GRADE.
4. DRIVEWAY SHALL HAVE A MAXIMUM SLOPE OF 1:12.
5. ALL CHANGES IN LEVEL ACROSS JOINTS SHALL BE FLUSH WITH
A MAXIMUM DIFFERENCE IN ELEVATION OF )f6 INCH.
m
C)
uj
C.)
-cc
u_ m Y2"EXPANSION
JOINT
VERTICAL CURB PER
COE STD E2.1 0
)�"EXPANSION ASPHALT PAVEMENT
VER11CAL CURB PER JOINT
COE STD E2.1 0 SECTION A -A
CONCRETE RAMP
1/2" RADIUS
6"
I
;
)M , _4,�.
VARIES FROM
4
6" TO 0"
2" MIN CRUSHED
SURFACING
TOP COURSE
APPROVED FOR CONSTRUCTION
CITY OF EDMONDS
DATE:
BY:
CITY'ENGINEERING DIVISIOV-
NTS
1 RADIUS
CONCRETE
CURB RAMP
VARIES
/ SEE PLAN
/V,
-
4
4-
1/2' PREMOLDED
JOINT FILLER
3
C4.01
7
COMPACTED
SUBGRADE
ASPHALT PAVING
NTS
17+00
- - - - - - - -
STEEL PIPE 3.0'1 r<
tZHANDRAIL (TYP)
�; F Of
6.0'
(TY6
i- -i
24.0
C*4
RAMP LANDING,
SEE SHEET C5.03
FOR GRADING
ov
INFORMA11ON
0 0 o 1
STA 16+59.20,
64.17' RT
TAPER DOWN
VER11CAL CURB R7
AT 1: 1 STA 16+64.98, 65.77' RT
TAPER UP VERTICAL CURB AT 1: 1
0" VERTICAL
CURB FLUSH WITH
PAVEMENT
RAM P PAVING ENLARGEMENT
NTS C4.021
1 =10'
CONCRETE
STAIRWAY,
7 EQUAL R \C4.03/
ISES
DMOND11
M ME= I SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS
EDMONDS, WASHINGTON
R E, 8 U B
JUN 18 2015
PAVING DETAILS
;CH(0)L BUILDING DEPARTMENT
OITY OF EDMONDS
'I STR I CT
SHEET
C 4.0 2 1
C1111
C�
co
_r3
0
0
V)
V)
C>
'd-
T 8
CD
LU
LLj
E
><
U--j 45
E; E
CN
(U
C)
NOTES:
1. STEPS IN FLIGHT MUST HAVE UNIFORM TREAD RUNS AND UNIFORM RISER
HEIGHTS NTH TOI FRANCE OF ±3/8
2. TREADS SHALL BE 11"MIN, 12"MAX. RISERS SHALL BE 5"MIN, 7"MAX.
3. REINFORCING STEEL SHALL BE ASTM A615 GR 60.
4. CONCRETE CLASS CL3000.
5. LANDINGS SHALL BE 0.5MIN, ADJACENT RAMP LANDING MAY BE PART OF
LANDING IF SLOPE CRITERIA AND SETBACKS FROM HANDRAILS ARE MET.
6. TREAD SURFACE SHALL HAVE GROOVES AT THE NOSE FOR TRACTION.
7. REMOVE BOTTOM RAIL FROM STEEL PIPE HANDRAIL FOR STAIRWAY
SECTIONS.
CON11NUATION
OF HANDRAIL
(PER PLAN)
1/2- EXPANSION JOINT
RAMP
LANDING STAIRWAY
12"MINI I
MI
12"
r3'��STEEL PIPE -
�C4.03/HANDRAIL,
SEE NOTE 7
Mrp 1;'—n"Tn 7'—q"MAy'
STA RWAY DETAIL
A
J
GRADE LINE
#4 TYP @ O'_1 f0c
#4 6141 @ 2$—O"OC
GRADE POINT
RAMP
6"
6 it
STAIRWAY LANDING
MIN
6'-0"
MIN
1 $—of)
-
5-0
7'—O"MAX
- A A
6"
6
CONTINUATION
00
06
OF HANDRAIL
(PER PLAN)
C)
1 I —on
MIN _ 16.0�_ 061
5%
0.5% 00
—
5%
(MIN)
(MIN)
(MIN)
—d
c:)
Y29"R
co
EXPANSION
JOINT
#4 BARS @ 0 oc
iQ7
GRADE
POINT
#4 6'-6" @ 2'—O"OC
SEE DETAIL A
4"
SIDE VIEW
6.0",
MOUND FOR
41..
. 4
SEE DETAIL B
2Y;STD STEEL PIPE --------
1
DRAINAGE
GRADE LINE -- -
#4 TYP @ 0 —11"
OC
(TYP)
16 GA GALV STEEL
#4 6f-61' @ 21-0" Oc
SLEEVE
06 #4 REINFORCING
#4 REINFORCING
00
.4 1d.A .
U BAR AT EACH
POST
U BAR AT EACH POST
d
SEE DETAIL FOR
STEEL
SEE DETAIL E
4.0'
HANDRAIL
NON —SHRINK GROUT
NON —SHRINK GROUT
4Y; SLEEVE
DETAIL
A
DETAIL B
CONCRETE STAIRWAY
NTS
2"0 EXTRA STRONG STEEL PIPE POSTS
(1"0
C4.02
U-)
TOP OF GRIPPING RAIL
CW WIDTH AS SPECIFIED
0.5% (MIN)
-------- Z' 4
<
COMPACTED SUBGRADE
it —of)
SECTION A -A
1. RAILING SHALL BE HOT DIP GALVANIZED AFTER FABRICATION
2. ALL POSTS SHALL BE PLUMB AND RAILS PARALLEL TO THE GROUND
3. PIPE MATERIAL SHALL CONFORM TO ASTM A 53
4. REINFORCING STEEL ASTM A 615 GR 60
5. IF THE CONCRETE WALK SLOPE IS 5% OR GREATER A GRIPPING HANDRAIL IS REQUIRED
6. PIPE DIAMETERS SHOWN ARE "NOMINAL" DIAMETERS AS GIVEN IN AMERICAN INS11TUTE
OF STEEL CONSTRUCTION MANUAL
STEEL PIPE HANDRAIL
NTS
3
C4.02
DRAWN BY DESIGNED BY
KWP/TY AJS
0 Call 81
CHECKED BY APPROVED BY
0 two busin 1601 5th Avenue, Suite 1600
ess days
TJE TJE before yo Seattle, WA 98101
DATE 206.622.5822
www.kpff.com
05/27/2015 lq*
S C A L E:
J 0 B No. :114407
NO. DATE BY CHID. APPR. REVISION AS SHOWN
a ; "ku h \0
�s�&4
io� , -
2"0 STD SEEL PIPE
POST OR
� 2-0 EXTRA STRONG
STEEL PIPE POST
RIPPING HANDRAIL (1-0
ID STEEL PIPE) SEE
)TE 5
1) STEEL PIPE
413 DETAIL B,
2"0 STD STEEL PIPE
IOST OR
� 2 of 0 EXTRA STRONG
')TEEL PIPE POST
GRIPPING HANDRAIL (1 it 0
STD STEEL PIPE) SEE NOTE 5
0
D
TEEL PIPE
SECTION B—B
2 0 STD STEEL PIPE POST OR
2"0 EXTRA STRONG STEEL PIPE POST
GRIPPING HANDRAIL
(1-OSTD STEEL PIPE) SEE NOTE 5
c DETAcIL C
2"0 STD STEEL PIPE
POST OR
2"0 EXTRA STRONG
19 -
-----."`SEEL PIPE POST
nm r�r
SECTION C—C GRIPPING HANDRAIL
-0 STD STEEL PIPE)
(1
SEE NOTE 5
_O"
3
0-1
DETAIL D
TtNn nr C11 A n A -r
WOOD CHIPS PER
\NDSCAPE PLAN
4.5'xlO' CONCRETE
SLAB WITH #5@12'
O.C. EACH WAY
CENTERED IN SLAB
PLAY FOUIPMENT FOUNDATION DETAIL
1/2' RADIUS (TYP)
CONCRETE SIDEWALK
PER PLAN
4
2" MIN CRUSHED
SURFACING TOP
COURSE
NTS
UNCOMPACTED
SUBGRADE
2
C4.01
3/8" PREMOLDED
JOINT FILLER (TYP)
ASPHALT PAVING PER PLAN
0" CONCRETE FLUSH CURB
NTS
_0�
E E
4
C4.01
SHEET
C4oO3
fml�_
0-
C�
,I-
C-3
.21
a)
(D
51
Cn
CD
0
Q)
CD
CD
Lj
NO
C4
Cl-
m
Cl-
co
I
fl�
w
Cn
CD
r:,:
LO
E
_:.3
LL.j
LLJ
V)
LLJ
U
=3
MR11
7 / 7 7 7 77 7 777777-7-/7/7Z
BASE BID
SAWCUT LINE
(TYP)
ADD—ALT #1:
SAWCUT LINE (TYP)
— — — — — — — — — — — — — — — — — — — —
r
L— — — --- —
PAVING NOTES
1. SEE SHEET C4.01 FOR PAVING NOTES.
Eli �11;��' -?'-I I" �Nll I Y11/1
LEGENP:
PROPERTY LINE
— — — — — — — — BASE BID SAWCUT LINE
---------- ADD—ALT #1: SAWCUT LINE
ADD—ALT #1: GRIND AND ASPHALT OVERLAY
............
00
00
co
cli
0%
_r�
41
;:0
m
m
Cn
CD
N3
co
M
mCD
'N
C%
PQ
(7)
CA
M
p
,&Raft.. 1 -en4-- Allamm.— mww�
0 10 20 40
momma.-
1 inch = 20 feet
DRAM BY DESIGNED BY S j TION EDMONDS SHEET
K WP /Ty AJS APPROVED FOR CONSTRILIC SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS
0 Call 81 WA C,
CHECKED BY APPROVED BY 0 two business days 1601 5th Avenue, Suite 1600 CITY OF EDMONDS EDMONDS, WASHINGTON
TJE TJE before you dig Seattle, WA 98101
DATE 206.622.5822 DATE: =Suw
www.kpff.com ItAs
05/27/2015 1Tff '?Z', 64 BY. Is ADDITIVE ALTERNATIVE -GRIND AND OVERLAY 0"I C4e04
S C A L E: V GIST.- 0m_V1
a OEM' DS
JOB No. :114407 ORAL CITY ENGINEERING DIVISION SCHODL auto' I! �ItIOF 600
NO. DATE BY CHID. APPR. REVISION AS SHOWN wm DISTRICT FOR PERMIT
F-
Ui
Cf)
a)
LLJ
C:)
C,
CY)
T
LLJ
u)
=3
0
LLJ
E
o W
><
LO
E
0-
4 -7
18+00
479t, R9.3
20+00
1
21+00
1
16+00
1
1[95 REF.2 (1319.94 M, 131�.62 P)
H AVE. W. STA 16+36.13, 71.56' RT-
END MI T STRIPE lz�.
&
�7
- -\\-379.957
I--
Uj TYPICAL 900 PARKING STALL
�C5.02j
16
STALLS CD
C->
@ 85A 6.51 '(TYP) STOP BAR
- - - - - - - - - - - - - - - - - - - - - -
b
d
- - - - - - -CS,
b
6
. . . . . ............
S9
TRAFFIC ARROW CENTER ON�: 1�4
STA 16+64.69, 97.56' RT
DRIVE AISLE (TYP OF 4)
-,oEND PAINT STRIPE
/I
- - - - - - - - - - --
5 CR fSWALK
B RS
0)PEDESTRIAN SYM
2(TYP OF 3)
ir-n n-1
EXTEND 4" SOLID WHITE FOG LINE
STRIPING (MATCH EXIgnNG)
11L //1 &
5' CROSSWALK BARS
BEGIN PAINT STRIPE
(MATCH CURB CONTROL POINT)
77':
BEGIN PAINT STRIPE
(MATCH CURB PC)
END PAINTED CURB AND
FIRE LANE STRIPING
rf -P-31
. ....... ..... .. . . ...............
- Nk 11
660.16 REF.3 (6EO.23 M)
ND
& & //z ZzL
PROPERTY LINE (TYP)
/h //z //1 &
299.95 C
TRAFFIC ARROW CENTER ON r2*'�
�C5.02�
DRIVE AISLE (TYP OF 4)
FILL IN AREA BETVEEN STALLS
NTH "NO PARKING' STRIPING 1
00
7 STALLS
9 STALLS @ 8.5x
z STALLS ii--85xi
cli ---7
B. 1A
/-IP5
6
::;!11::1'A�BEGIN PAINTED CURB TYPICAL 60*
AND FIRE LANE STRIPING, PARKING STALL �C5.02/
SEE NOTE 10
STA 17+05.58, 142.02' RT
BEGIN CENTER PAINT STRIP
STA 17+07.96, 152.76' RT
END PAINT STRIPE, MATCH CENTER OF ---- - ---------------
- - -- - ----------------
PAINT STRIPE TO FACE OF CURB
14+00 PROPERTY
5' CROSSWALK BARS BEGIN PAINTED CURB
�C5.02� AND FIRE LANE STRIPI
SEE NOTE 10
r.
TRAFFIC ARROW
CENTER ON DRIVE
AISLE (TYP OF 6)
,"'(TYP) 15+00
N01'06'38"E 131
STOP BAR 106
P7 ADA PARKING 8
ENLARGEMENT C5.02
S2
--'NS 14+40.00, STA 15+06.19, 8.5 5
35 1 T 71.56' RT
BkE N EN LANE BEGIN PAINT
P NOTE 11 STRIPE
M
TRAFFIC Ag, W
CENTER ON DRIVE
AISLE (TYP OF 2)
17111L LANL SIRIPING <
TRAFFIC4ROW STA 14+64.22, 78.30' RT
CENTER ON DRIVE 7 - - - - - - - - - C) -PAINT-STRIPE-GONTROL MINT
AISLE (TYP OF 4)
END BROKEN LANE STRIPE
7;`BEGIN;�SW PAIN S'
M 'JH CURB TANGENT
- - - - - - - - - - - - - - - - - - - - OF
RS
- - - - - - - - - - - 8' 1CR SWA
L R- F STA 16+36.05, 62.79' RT C5.
CENTER "ONE W Y" PAINT, SEE
STOP BAR (rfP OF 2)
NOTE 12
STRIPING AND SIGNAGE NOTEIS:
1. SEE SHEET GO.02 FOR GENERAL NOTES. 10. ALL CURBING ADJACENT TO FIRE LANES SHALL BE PAINTED YELLOW, UNLESS
OTHERWISE NOTED. YEH OW PERIMETER STRIPING SHALL BE PLACED 12 INCHES
2. SEE SHEET CO.01 FOR MASTER SITE PLAN AND OVERALL SITE CONTROL FROM ALL PAINTED CURBING. PERIMETER STRIPING SHALL BE SOLID, 4 INCHES
LAYOUT. WIDE, AND MARKED WITH THE WORDS 'FIRE LANE - NO PARKING" AT
INTERVALS NOT EXCEEDING 100 FEET. WORDS SHALL BE 12 INCHES HIGH AND
3. SEE SHEET C6.01 FOR HORIZONTAL CONTROL TABLES. AOO 4t(14 YELLOW IN COLOR. MATCH EXISTING PERIMETER STRIPING AND CURB PAINTING
AT TRANSITIONS.
4. ALL STRIPING IS PARALLEL. OR PERPENDICULAR TO THE PROJECT BASELINE
UNLESS OTHERWISE NOTED. 11. BROKEN LANE PAINT STRIPE SHALL BE 4" WIDE 10' LONG STRIPES PAINTED
5. ALL STATIONING AND DIMENSIONING ARE TO, CENTER OF STRIPING, UNLESS WHITE, SPACED AT 5' INTERVALS.
OTHERWISE NOTED. 12. "ONE WAY" PAINT LETTERING SHALL CONFORM TO MUTCD STANDARDS.
6. ALL STRIPING RADII ARE 3.0 FEET, UNLESS OTHERWISE NOTED.
7. ALL DIMENSIONS MARKED WITH AN ASTERISK (*) ARE FOR REFERENCE ONLY.
8. ALL STRIPING SHALL BE 4" SOLID MITE PAINT UNLESS OTHERWISE NOTED.
9. SEE SHEET C4.01 FOR PAVING PLAN.
00
V)
C6
25.0' 8.0' 1 15.0 18.0 24.0'
5.0'
I N11 r - - - - - - - - - -
TRAFFIC ARROW
CENTER ON DRIVE
AISLE (TYP OF 3)
END PAINTED CURB AND
VA 19+69.86, 65.1/y T
END PAINT S/TR/IPE
"NO PARKIN
STRIPING
PROPERTY LINE
4" SOLID PAINTED STRIPE
SIGN
Qk, ADA PARKING SYMBOL (8/C5.02)
TRAFFIC DIRECTIONAL ARROW (2/C5.02)
ammmmm STOP BAR (4/C5.02)
CROSSWALK BAR (1/C5.02)
"NO PARKING" STRIPING (5/C5.02)
I I Cl)
1 06TH AVENUE I
CD
0z
m
m
Ln
STA 21+01.58, 114.83' RT
END PAINT STRIPE
S5
Z4, 00
m z:
mC)
STOP BAR S6
C5.02�
Cli m
z:
ICA
Amftmm.
0 10 20 40
1 inch = 20 feet
DRAWN BY DESIGNED BY EDMONDI SHEET
AJS 41
KWP TY S j APPROVED FOR CONSTRUCTION SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS
0 Call 811 rj WA CITY OF EDMONDS EDMONDS, WASHINGTON
CHECKED BY APPROVED BY 0 two business days 1601 5th Avenue, Suite 1600
TJE TJE before you dig Seattle, WA 98101 DATE:
206.622.5822 � R"e- Swim
DATE WWW.kpff.com 64 1 C5901
05/27/2015 IST BY. STRIPING AND SIGNAGE PLAN
S C A L E: IONAL " % Afqwta
IONAL tKIREERING DIM, log SCHUDL
NO. DATE BY CHID. APPR. REVISION J 0 B No. :114407 AS SHOWN I DISTRICT FOR PERMIT
12"
(TYP)
C)
�21
C:, a-
LO ED
5 6
(TYP)
TRAVEL LANE
6
12"
(TYP)
10" ELLIPSE
"B" AXIS
V-6" ELLIPSE
"A" AXIS
CROSSWALK
WHITE THERMOPLASTIC
TORCHDOWN BARS
CONFORMING TO
MUTCD STANDARDS (TYP)
NOTE:
1 CROSSWALK CENTERLINE SHALL BE
PERPENDICULAR TO TRAVEL LANE CENTERLINE.
CROSSWALK BARS
NTS
.0.
4!' SOLID WHITE
PAINT STRIPE (TYP)
TYPICAL NO TARKING STRIPING
SCALE: NTS
TYPICAL 60-DEGREE PARKING STALL
SCALE: NTS
C5.01
5
C5.01
CENTER POINT
OF ELLIPSES
8 $—on
3 $—off 29-8"
8"
r
_O"
2
2'-411
ELLIPSE "B" 3'-8"
A LLIPSE "A
AXIS
NOTE:
1 . MARKINGS SHALL BE CENTERED IN TRAVEL LANE.
2. MITE THERMOPLASTIC TORCHDOWN ARROWS
SHALL CONFORM TO MUTCD STANDARDS (TYP)
TRAFFIC ARROWS
PAINT STRIPE OR
4" SOLID MITE PAINT FACE OF CURB (PER
STRIPE (PER PLAN) PLAN)
6
C5.01
-
(PER WSDOT STD PLAN M-24.40-01)
NTS
18.5'
WHITE THERMOPLAS11C
TORCHDOWN ARROW
:2C-4
ELLIPSE "A" SYMBOL & LANE
911311 CENTERLINE
ELLIPSE
SYMBOL AND
TRAVEL LANE
ILI'r
WHITE TRAFFIC P1
TYPICAL 90-DEGREE PARKING STALL
SCALE: NTS
2
C5.01
STAIL C
WHITE THERMOPLASTIC
TORCHDOWN ARROW
CONFORMS TO MUTCD
STANDARDS (TYP)
.............
. . . . . . . . . . .
. . .. ... . ,jX
.
1
7
3'-0
NOTE:
1 . GRID IS 4" SQUARE.
PEDESTRIAN SYMBOL
NTS
C14
12"
RMV0
MKING
SIGN FOR VAN PARKING--/
STALLS MUST CONTAIN
THE WORDING "VAN Ui
ACCESSIBLE" MUTCD
STANDARD R7-8A
SLOPE TO
NO
SIGN MUST CONFORM
TO MUTCD STANDARD
R7-8
METAL SIGN: BOLT
TO PIPE COLUMN
W/ U—BRACKETS
SIGN MUST CONTAIN
ARROW TO THOSE
SPACES THAT ARE
SHARED
2" SCHEDULE 40
GALV. PIPE
THREADED ONE
END
DRAIN
I/ . _. -
7\77 %
2'-2" SCHEDULE 40 _cD
:2�
GALV. PIPE (EXTENSION) c-j :m
THREADED ONE END
4" WELDING STUDS 12" DIA.
WELDED TO CONCRETE FOOTING.
ADA PARKING SYMBOL EXTENSION ADA PARKING
7
C5.01
DRAWN BY DESIGNED BY
KWP/TY AJS
CHECKED BY APPROVED BY 0 Call 811
0 -two business days 1601 5th Avenue, Suite 1600
TJE TJE before you dig Seattle, WA98101
DATE 206.622.5822
05/27/2015 www.kpff.com
S C A L E:
NO. DATE BY CHID. APPR. J 0 B No. :1144
L, REVISION AS SHOWN
GN
VAN ACCESSIBI F
4" SOLID MITE ADA PARKING SIGN ADA PARKING SIGN
PAINT STRIPE (TYP OF 2)
GRAVEL PATH, —
PER PLAN =u — C, — 7 � I
0 0 o I C) C) 0 0 0 1 C) o , C) G Q 0 0 o 0 0 0 0 -U-)
0 Z) 0 �Z) 0 �Z) 0 �Z) 0 �Z) 0 �Z) 0 Z) 0 �Z) 0 �Z) 0 0
VERTICAL CURB PER
COE STD E2.1 0 EQ EQ
fc 't.
8.5' 8.5' 5. 0'
ADA PARKING SYMBOL --/ -I-
(TYP OF 3) (Typ)
ADA PARKING ENLARGEMENT
SCALE: NTS
-8
C5.01
METAL SIGN: BRACE PER
WSDOT STANDARD PLAN
G-50.1 0-01
SIDEWALK OR LANDSC/
PER PLAN
2 FT WIDE MITE
THERMOPLAS11C
TORCHDOWN STOP BAR
4" WHITE PAINT STRIPE
(PER PLAN)
-STOP BAR SHALL MATCH
EDGE OF PAINT STRIPE
WHERE APPLICABLE
STOP BAR SHALL MATCH
FACE OF CURB WHERE
APPLICABLE
CURB PER PLAN
NOTES:
1 - STOP BARS SHALL CONFORM TO MUTCD
STANDARDS.
2. STOP BARS SHALL BE PROPORTIONAL TO THE
LANE OF 'RAVEL.
TYPICAL STOP BAR DETAIL
SCALE: NTS
rFNTFP qlrKI nN Pn(ZT
4 TABLE ON SHEET C6.01
3 )TS NTH MULTIPLE SIGNS
-4
C5.01
I TABLE ON SHEET C6.01 FOR
PE AND LETTERING
SQUARE 12 GAUGE
UBE
1'0 CONCRETE.
SLOPE TOP TO DRAIN IN LANDSCAPE AREAS.
HOLD TOP BELOW PAVEMENT AT SIDEWALKS.
SIGN POST DETAIL
SCALE: NTS
EDMONDS
S j APPROVED FOR CONSTRUCTION SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS
c�j WA CITY OF EDMONDS EDMONDS, WASHINGTON
DATE...imL �m M/.r RESU13
>4 6 - w '', ; JUN 0 12015
IST_ BY. 4 ............................. r111111 STRIPING AND SIGNAGE DETAILS
40NAL 1*_L�ENGINERING DIMSION SCH(DL BUILDING DEPARTMENT
__ DISTRICT clTy OF EDMONDS
9
C5.01
SHEET
C5*02
FOR PERMIT
c -3
Ui
GO
r-
CD
t-
cn
m
T
C3- r
F4 U)
n �3
(D E
CN
cu
�2 f-,
L�j
C:�
r-
CZ)
0
0
10
LLJ
_0
0
cn
C:)
a)
T
0 CD
CD
CD
E
ca cn
Ln
3 E
EZ
C= 0
FILTER FABRIC -
SECURED TO 2" X 2"
14 GA. WIRE FABRIC
EQUAL
2* X 2" WOOD OR
EQUIVALENT
81- 12,
PLACE 3/4-1.5- WASHED GRAVEL IN
THE TRENCH AND ON BOTH SIDES OF
FILTER FABRIC FENCE ON THE SURFACE.
RATE
U
( CD
ZO
j
cu
CONTRACTOR/ DE V ELOPER SHALL MAINTAIN AND REPLACE
STRAW BALES TO INSURE PROPER EROSION CONTROL.
FILTER FABRIC MATERIAL IN
CONTINOUS ROLLS. USE STAPLES
OR WIRE RINGS TO ATTACH
FABRIC TO WIRE,
WIRE MESH SUPPORT F
TO SUPPORT FILTER F
-BURY BOTTOM OF FILTER
MATERIAL 8' TO 12'
6' MAX.
2' X 2' WOOD POSTS OR
EQUIVALENT
CITY INSPECTION REQUIRED ON ALL
EROSION CONTROL METHODS BEFORE
OTHER WORK CAN BEGIN,
CITY.:,OF- "EDMONDS
REVISIONS STANDARD DETAIL
AVHK'UVEIJ BY 171 L
FLTER FAMIC FM FILTRATIONSIVOIS
1890 DATE SCALE DWG NO.
-199 7/24/01 NTS E1.1
FILTER FABRIC FENCE
NTS
4
ILTER SOCK WITH
OVER FLOW HOLES
.4
4
THIS APPLICATION SHALL BE MAINTAINED
AT ALL TIMES DURING CONSTRUCTION
PERIOD,
SEDIMENT SHALL BE REMOVED ON A
REGULAR BASIS TO MAINTAIN FILTRATION
EFFECTIVENESS,
CITY INSPECTION REQUIRED ON ALL EROSION CONTROL
MEASURES BEFORE WORK CAN BEGIN,
:-0 MONDS
CITY 0
REVISIONS STANDARD DETAIL
AFf-t<IjVL1J I L
D. GEBERT� 10102t
D. GEBERT 05/19/05 THMMY=ffTWFORCATMU%S
0 0 0
1,99 -1990 D. GEBERT 05/05/06 DATE SCALE DWG NO-E1.3
1/0,/J�, 7/24/01 NTS
R. ENGLISF 11/017/1 1 1
CATCH BASIN PROTECTION
NTS
2_
C1.01
CITY INSPECTION REQUIRED ON FORM
WORK PRIOR TO POUR
EXPANSION JOINT
10' DUMMY JOINT
4 .. t .
.'4 A d4
.'4
A 4 4 " , . . . q. . * - . ..
'd . '4.:
4
4
A
A4 4' -A
'A 4.;
A..
4 ''4
�A A A' 4:
4
4 A 4-
4. . A
A 4
.d
10' O.C. 5' O.0 2' MIN.
SAW CUT ACP A MIN.
OF 2' FROM EDGE OF
PLAN GUTTER.
FULL DEPTH 1/2" EXPANSION
JOINT MATERIAL
2%
A
A . 4
A
4
=m
A A
4
- -
4'.
-. 4A.
A
Da W-11 1�_
_A
.
,�COMPACTED
UNDISTURBED EARTH OR
NATIVE MATERIAL
SEC11ON
2' MIN.
UNLESS OTHERWISE SPECIFIED
SAW CUT
BY ENGINEER
2"- 5/8" MINUS CSTC
N 0 T E:
1. CONCRETE SHALL BE CLASS 3- 300OPSI
2. CONCRETE SHALL BE BROOM FINISHED
3. SIDEWALK THICKNESS SHALL BE 5-1/2".
4. SIDEWALK THICKNESS AT DRIVEWAYS SHALL BE 6" THICK.
5. CURB AND GUTTER SHALL BE POURED SEPARATELY FROM SIDEWALK
6. CONCRETE SHALL BE SPRAYED WITH CLEAR CURING COMPOUND
OR SHALL BE COVERED AND KEPT MOIST FOR 72 HOURS.
7. SAW CUT AND REMOVE ACP PAVEMENT A MIN. OF 2' FROM GUTTER
FACE TO INSURE ADEQUATE COMPACTION OF ACP AND GUTTER
SUBGRAIDE
CITY.:OF-
"EDMONDS
REVISIONS
AFHHUVED BY _DA I E
ffGEBERT
STANDARD DETAIL
D.
4/27/05
CONCRIETE SIDEWALK
Est. 1890
D, GEBERT
G B
04/2/07
DATE 7/24/01
SCALE
1 NTS
DWG NO. E2.13
CONCRETE SIDEWALK
NTS
3 -
C4.01
101,
2-1 2
5"
1- /2" R
7,
PLACE SCORE MARKS EVERY 10'
1" MAX.
SLOPE, 4
-4
4
4
DRIVEWAY WING OR CURB RAMP SLOPE
CONCRETE CURB SHALL BE NO LESS THAN 3" IN HEIGHT
CONSTRUCT OUT OF ACP PAVEMENT
m
NOTE: NOT TO BE USED IN R.O.W. EXCEPT
TO REPAIR EXISTING EXTRUDED CURBING.
0
-EXTEND PAVEMENT 1.3' FROM THE FACE
CURB IF NECESSARY TO SUPPORT
ACP PAVEMENT EXTRU DED CURB
�CE 6" COMPACTED
K5 " CSTC BELOW ACP
8"
TrNSION
CITY.: -OF' "EDMONDS
REVISIONS
APPHUVEB By ijAiL STANDARD DETAIL
D. GEBERT 06/29/05
CONC. EXTRUDED CURB
DATE SCALE DWG NO.
,Est. 1B913 7/24/01 NTS E2.7
EXTRUDED CURB
NTS
4 -
C4.01
CITY INSP CTIDN REQUIRED DN FDRM VDRK PRICR TEI PDUR. DETECTABLE WARNING PATTERNS
DETECTABLE RNING PATTERN AREA ACCESSIBLE RAMP SHALL BE PLIURED SEPARATELY (TRUNCATED DO S)
SHALL BE YELLOW. FRDM CURB AND GUTTER.
A
13 RAMP 1/2, RAMP SHALL 13E FLUSH 6' MINIMUM CONCRETE CURB AND GUTTER
CIJ V47H GUTTER LINE 6-1 OR 16" VERTICAL CURB (TO MATCH
ENRON
RUNCATED DO S)
EXISTING CURBING) SHALL EXTEND
PE
/2" X 4" EXPANSION JOINT MATERIAL ;;j I _� �_ I - I TO END OF RADIUS.
:. -.1 - ' 55'
A MIN. MAX. 1-1/l/ ./4' 1 , I CODE EXTRUDED CURB SHALL START
A 1 5/8' 2 3/8' 0, CONCRETE CURB AND G T -9V/ COMPACTED SUBGRADE. ADD CRUSHED AT END OF RADIUS
B 5/8' 1 1/2' SEE DETAIL E-PS ROCK BASE AS REOUIRED
4.. AN C 7/16' 3/4' FZ V NOMINAL DIMENSIONS > (NEW CONSTRUCTIDN () RADIUS VARIES TRANS11ION SLOPE SHALL
SIDEWALK ZD C D 7/8' 1 7/16' 0 1/2- FULL DEPTH EXPANSION JOINT MATERIAL TYPE 2 CURB RAMP BE 1: 12 (TYP) TYPE 2 CURB RAMP
SECTION B-1 5' LONG RAMP MIN.
cl TRACTION GRID PATTERN 5' LONG RAMP MIN.
-4 TACTILE WARNING TEXTURING (SEE DETAIL E-2.15)
DETECTABLE WARNING PATTERNS 0
4 b* 71 (TRUNCATED DOMES) (SEE DETAIL E-2.15) CL
PAVEMENT DETAIL A 0
o
ELEVATION o0oc .0.
< SIDEWALK oo.o -.0.
NEW CURB AND GUTTER 3.5' oo.
-6-5) - A <- gg.
IT MAIN/R V WIDE TACTILE STRIP ITIP) o-.
DETAIL B INSTALL 1/2' EXPANSION L AM ALL LOCAT113NS
... .... TERIAL (TYPICAL) SI
0 (T IAL)
CSTC
< 4 ECL
LLL
LLL \PLACE 1' WIDE TACTILE A <-
LLL VIEW B-2
_LL 1' BEHIND START OF RAMP
LL
LL
�o L BE YELLOW, PLACE FULL DEPTH EXPANSION JOINT
0 < L w 'AMP 1/2' BETWEEN C/G AND HIGH TRAFFIC LOAD GUTTFR,
IF WING AND C/G ARE NOT POURED AS ONE UNIT
574, CURB/GUTTER AND WING FOR HIGH TRAFFIC
LOAD GUTTER MAY BE POURED AS ONE UNIT.
SAW CUT AS REQUIRED A B ACP ACP FULL DEPTH EXPANSION JOINTS SHALL BE PLACED
IF WIDTH OF OPENING EXCEEDS 15'.
101, REMOVE AND REPLACE ol MIN. MAX. 1 2
Do NOMINAL DIMENSIONS
CURB AND GUTTER A 1 3/8' 2 3/8' PLAN
I 1`7+�; TRACTION GRID 0
rri-T-r-r-r-r-i SEE DETAIL B R 5/8, 1 1/2' ID C
I - ' ZV -1 TRACTION GRID PATTERN
NOTES: 5/8" MINUS CSTC C 7/16' 3/4' cl) TACTILE WARNING TEXTURING SECTION A -A
1. FORMS SHALL BE TRUE TO LINE AND GRADE EXIST SIDEWALK D 7/8' 1 7/16' D_
AND SECURELY STAKED. SAW CUT AS REQUIRED 1' TACTILE WARNING STRIP (TYP.) SEE DETAIL A DETAIL A
2. EXPANSION JOINTS SHALL BE PLACED ADJACENT ELEVATION
TO CATCH BASINS.
3. EXPANSION JOINTS SHALL BE EVERY 10 FEET DETAIL B CITY INSPECTIL7N REOL)IRED L7N FEIRM WORK PRI17R TD POUR,
AND DUMMY JOINTS EVERY 5 FEET. ACCESSIBLE RAMP 3HALL BE POURED SEPARATELY
4. EXPANSION JOINTS SHALL HAVE 1/2" TO 5/8" WIDE NOTE, NOTEi FROM CURB AND GETTER. CONCRETE SHALL BE CLASS 3- 300OPSI
PREMOLDED JOINT FILLER.
5. CONCRETE SHALL BE CLASS 3- 300OPSI. 1. AT LOCATIONS WHERE NEW RAMPS ABUT EXISTING CURB, GUTTERS, PLANTER STRIPS, AND SIDEWALKS, NOTE: CITY ENGINEER SHALL DETERMINE APPLICABLE 00000.00.o600000.00
6. FINISH SHALL BE LIGHT BROOM. CONSTRUCT NEW RAMPS TO MATCH ADJACENT SURFACES. 1. DETECTABLE WARNING PATTERNS SHALL BE YELLOW IN COLOR, SET AND SECURED IN CONCRETE, AND SHALL MEET COMMERCIAL TYPE ENTRANCE BASED ON LOCATION & OTHER oo.0 0�6506 0
7. CURB SHALL BE SPRAYED WITH CLEAR CURING 2. ALL CONCRETE SURFACES SHALL HAVE A LIGHT BROOM FINISH. THE DIMENSIONS AND SPACING SHOWN. SITE CONDITIONS.
COMPOUND OR SHALL BE COVERED AND KEPT MOIST 2. TACTILE WARNING TEXTURING SHALL BE DONE WITH AN EXPANDING METAL GRATE PLACED AND REMOVED FROM WET
FOR 72 HOURS. 3, CONCRETE SHALL BE SPRAYED WITH A CLEAR CURING COMPOUND OR SHALL BE COVERED AND KEPT MOIST CONCRETE TO LEAVE A DIAMOND PATTERN AS SHOWN, THE LONG AXIS OF THE DIAMOND PATTERN SHALL BE
8. ALL SIDEWALKS POURED BEHIND CURB IN FOR 72 HOURS. PERPENDICULAR TO THE CURB, GROOVES SHALL BE 1/8' DEEP AND 1/4' WIDE
DRIVEWAY AREAS SHALL BE 6" THICK OVER 2" OF
CSTC WITH SUBGRADE COMPACTED TO 95% MAXIMUM 4. DETECTABLE WARNING PATTERNS (TRUNCATED DOMES) SHALL BE REQUIRED ON ALL PUBLIC STREETS WITH A 3. ALL CONCRETE SURFACES SHALL HAVE A LIGHT BROOM FINISH.
DENSITY. CURB RETURN,AND PRIVATE STREETS SERVING FIVE OR MORE LOTS. TRACTION GRID (DIAMONDS) TO BE USED 4, DETECTABLE WARNING PATTERNS (TRUNCATED DOMES) SHALL BE REQUIRED ON ALL PUBLIC STREETS WITH A CURB
AS INDICATED RETURN AND PRIVATE STREETS SERVING FIVE OR MORE LOTS. TRACTION GRID (DIAMONDS) TO BE USED AS INDICATED, CURB AND CUTTER SHALL BE POURED
THIS TYPE OF CURB SHALL ONLY BE. USED To 5' FOR NON -INTERSECTION CURB RAMPS ON PRIVATE PROPERTY, THE STANDARD DIAMOND PATTERN MAY BE SEPARATELY FROM THE SIDEWALK. ASPHAL T SURFACE
USED AS INDICATED IN DETAIL A. 5. FOR NON -INTERSECTION CURB RAMPS ON PRIVATE PROPERTY, THE STANDARD DIAMOND PATTERN MAY BE USED AS CITY INSPEC77ON REQUIRED ON FORM WORK
REPLACE EXISTING VERTICAL CURBING INDICATED IN DETAIL A. PRIOR TO POUR.
T N. 'D CITY-:-OF-EDMONDS
-.C.1-TY -0-F-.
CITY
REVISIONS REVISIONS REVISIONS
AFFHUVLD BY BAIE STANDARD DETAIL APPROVED BY DATE STANDARD DETAIL APPROVED BY DATE STANDARD DETAIL REVISIONS STANDARD DETAIL
AFFHUVEJJ BY 11AIE
D. GEBERT 4/27/05 CONC. VERTICAL CURMI D. GEBERT 10/6/03 CURB RAMP TYPE 4 D. GEBERT 03/24/05 RAMP DETAIL FOR TYPE 3 AND TYPE 4 RAMPS A GEDERT 10/6/03 MULTI-FAMILYI COMMERCIAL HIGH TRAFMC LOAD DRIVEWAY ACCESS
D. GEBERT 5/18/06 D. GEBERT 06/27/05 DATE 01 SCALE DWG NO. 18 D. GEBERT 06/27/05 DATE CALE DWG NO. D, GEBERT 04/2/07 (WITH APHALT DRIVEWAY APPROACH) DWG
Est. 189Q DATE 7/24/01 SCALE NT WG NO. F-2.10 1890-19130 D. GEBERT 04/2/07 7/24/ NTS E2.117 9 -1 9cjI3 D. GEBERT 04/2/07 7/24/01 NTS E2.23 Est. 189Q DATE 7/24/01 NTS NO. E2.27
MIMES= I m 1
06/27/05- REVISED NOTESj REMOVED TRACTION GRID GRAPHIC
06/27/2005 DELETED GRAPHIC REFERENCING TRACTION GRIDSj UPDATED NOTE 4 8/17/06, ADDED TEXT FOR CLARITY
8/17/06, ADDED TEXT FOR CLARITY, ADDED TWO DETAILS
VERTICAL CURB CURB RAMP TYPE 4 RAMP DETAIL FOR TYPE 4 rT� DRIVEWAY
NTS NTS NTS C4.01 NTS C4.01
� - �01 � - �01
DRAWN BY DESIGNED BY EDMONDS SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS SHEET
KWP/TY AJS 0 Call 811 rjy WA APPROVED FOR CONSTRUCTION
CHECKED BY APPROVED BY q two business days 1601 Sth Avenue, Suite 1600 CITY OF EDMONDS EDMONDS, WASHINGTON
TJE TJE before you dig Seattle, WA 98101 DATE RESUM
DATE 206.622.5822 :
05/27/2015 www.kpff.com 4 4 JUN 0 12015 C7*01
.a�IS 01
S C A L E: BY. CITY OF EDMONDS DETAILS
LaTY (ENCANIFERING DIAS OF
AL SCHWL 61IJILDING DEPAR1VANT
NO. DATE BY j CHID. I APPR. I REVISION JOB No. :114407 AS SHOWN I I DISTRICT oily _t)MONUS FOR PERMIT
3RI:
C:)
C�
U)
E
Q)
Uj
_r3
0
U0
C=)
E fffi:
0 =
co cn
Ln
E; F-
c"4
=3
-, ><
MAXIMUM TRENCH
PAY WIDTH
(SEE TABLE BELOW)
4,%
ME
2C
F
R000
AI
-
8" MIN 8' MIN
SEE NOTE 1
NOTE:
1. MAXIMUM WIDTH OF TRENCH AT TOP PIPE
36" FOR PIPE UP TO AND INCLUDING
12" NOMINAL DIAMETER
1
I.D. PLUS 18" FOR PIPE LARGER THAN 12'
3EE STANDARD DETAIL E2.3
BANK RUN GRAVEL FOR
TRENCH BACKFILL
(1-1/4" MINUS) CSBC
PER COE MOD
9-03.19 OR SUITABLE
EXCAVATED MATERIAL
AS APPROVED BY CITY
ENGINEER (SEE NOTE
2 BELOW)
BEDDING MATERIAL
(5/8" MINUS)
CRUSHED PER
COE MOD
9-03.16.A.2
(SEE NOTE 2
BELOW)
TABLE 1: MAX. TRENCH PATCH PAY WIDTH
TRENCH
DEPTH
MAX PAY WIDTH
1' -
4'
40"
4' -
10'
60"
10' -
20'
72"
NOMINAL DIAMETER
2. REFER TO CITY OF EDMONDS MODIFICATIONS TO DIVISION 9 OF WSDOT STANDARD
SPECIFICATIONS. FOR MATERIAL GRADATION AND ADDITIONAL INFORMATION.
3. TRENCH BACKFILL SHALL MEET A MINIMUM COMPACTON OF 95% DENSITY PER ASTM D 1557.
E D
--Ty.
-0
REVISIONS
APPROVED BY DATE STANDARD DETAIL
D. GEBERT 07/28/05 TYPICAL TRENCH SECTION
D.GEBE T 04/02/07
DATE 7/24/01 SCALE NTS DWG NO. E4.2
R. ENGLISH 10/04/11 1 __ 1
TYPICAL TRENCH SECTION
STANDARD TYPE "A"
CURB/GUTTER DETAIL
(E2.8)
2' MIN SAW CUT
NTS
\2" CLASS "B" ACP
TACK CONC. SURFACE 4" -5/8" MINUS CSTC
2"- 5/8" MINUS CSTC
NOTE:
PAVEMENT COMPACTION- 91% RICE DENSITY
SUBGRADE AND TOP COURSE COMPACTION - 95% (ASTM1557)
CITY INSPECTION REQUIRED ON ALL EROSION CONTROL
MEASURES BEFORE WORK CAN BEGIN,
CURB/GUTTER FORMS AND SUBGRADE INSPECTION REQUIRED
PRIOR TO POURING AND BEFORE APPLYING ACP
CITY -E-. D: M.
REVISIONS
APPROVED BY DATE STANDARD DETAIL
D. GEBERT 4/27/05 ASPHALT WALKWAY
D. GEBERT 04/2/07 DATE 7/24/01 SCALE NTS DWG NO. E2.12
Est. 1890
ASPHALT WALKWAY
NTS
REVISION
C3.01
5-
C4.01
I
IL
MOUNT HYDRANT PLUMB
PROVIDE 3' MINIMUM CLEARANCE
AROUND HYDRANT
BACKFILL BEHIND WALL WITH
1'-0" MIN WIDTH OF CLEAN,
2H: I V &fAX
WELL DRAINING GRANULAR
DOUBLE SIDED OWE RAISED PAVEMENT
FILL PER MANUFACTURER'S
6' BEHIND BACK OF
MARKERS
RECOMMENDATIONS
4,,,
-MIN,
SIDEWALK
I
4' STORZ ADAPTER
6" TOPSOIL OR
GRAVEL OVER GEOTEXTILE
� m E E W
w ALIGN VALVE BOX EARS PARALLEL WTH TEE WITH FLANGED
x X N N EC
C 0
< THE WATER LINE IT SERVES CONNECTION FOR
BLOCK CAP GROUTED IN PLACE
Hy 1) R AN
HYDRANT VALVE:
z
cu L:
FILL IN VOIDS W/ 1/2- TO 3/4
4' MIN 6' MAX -
z w w
MINUS CRUSHED ROCK OR PER
MANUFACTURER'S RECOMMENDATIONS
3' x 3' x 3.5' THICK
;> f=1
13 <
2H. I V &IAX
CONCRETE PAD
, cq O�
4 < U)
ISH GRADE
1 GRADE
AROUND HYDRANT
,-FIN
m
w
1 CY 1-1/2' WASHED
,-CAST
ADJUSTAB LE
IRON ADJUSTABLE
ROCK . 1' MIN ABOVE
FL x MJ 6' R.W.
VAL X
GEOTEXTIL
w
DRAIN HOLES AND
GATE VALVE
FILTER FAB
ROAD SURFACE/
X �: �-
0
AROUND HYDRANT TO
REST INED JOINTS
10 MIL PLASTIC
z
:2 Ld
NE
BOTTOM OF DITCH LINE. -
MEGA UG OR EQUA
BETWEEN BLOCK &
B
S
COVER TOP AND SIDES
FROM I YDRANT T
TE
EE
WITH MIRAFI 16ON OR
SHY
-
APPROVED EQUAL.
THRUST
STAKE
BLOCK
z
2' MIN CLEARANCE
+
BETWEEN BLOCKING
MIN 6" DIA PERF RIGID
DRAIN PIPE CENTERED
HORIZ.. IN BEDDING. SLOPE THIS DISTANC
C
TO DRA N AND ONNECT TO NOT BE LESS THAN
STORM DRAIN SYSTEM. LOWER WALL HEIGHT NDISTURBED NATIVE SOIL
UTS.
PROVIDE CLEANO WITHOUT A PERMIT OR COMPACTED GRANULAR
BASE. AS REQUIRED
AND A DESIGN BY A
LICENSED ENGINEER.
PRIVATELY OWNED BLOCK WALLS SHALL NOT BE CONSTRUCTED IN CITY R.O.W.
OR OVER PUBLIC EASEMENTS
IF WALL ABUTS A PRIVATE DRIVE OR DRIVEWAY,
B
[A 2' SHY DISTANCE SHALL BE MAINTAINED BETW N
T ::
W LL
THE WALL FACE AND EDGE OF ROAD SURFACE
NOTES:
1. MODULAR BLOCK WALLS WITH GEOGRID REINFORCING SHALL BE DESIGNED AND STAMPED BY A STATE LICENSED
PROFESSIONAL ENGINEER, IF HEIGHT EXCEEDS 4'..
2. MODULAR BLOCK WALLS OVER 4"-0" IN HEIGHT AND/OR LOCATED IN A CRITICAL AREA, OR MEADOWDALE EARTH
SUBSIDENCE LANDSLIDE HAZATRD AREA, REQUIRE A BUILDING PERMIT AND MUST BE DESIGNED AND STAMPED BY A
STATE LICENSED PROFESSIONAL ENGINEER.
3. MODULAR BLOCK WALLS OVER 3'-0" IN HEIGHT MEASURED FROM ORIGINAL GRADE ARE NOT ALLOWED WITHIN
BUILDING SETBACK AREAS.
Y
-C 17
REVISIONS STANDARD D ETAI L
APPROVED BY DATE.
D. GEBERT 4/27/05 - MODULAR BLOCK WALL
D. GEBE 9/9/05 - DATE [SCALE DWG NO.
789 C30 ERT 4/2/07 4/1/03 NTS E8.12
1 1! - - - - ____ - I �
09/09/2005: ADDED PROVISIONS 707'�TIERED WALLS; CLARIFIED DIMENSIONING / NOTES
REVISED: 4/2/07- SCALED DIMENSIONS AND TEXT DOWN TO CORRECT SIZE
--MODULAR BLOCK WALL 1(
NTS
CITY INSPECTION REQUIRED ON FORM
WORK PRIOR TO POUR
5-1/2"
1" R
1" BATTER
4 . 4 .
I "R
0.05 FT/F
4
4
. . 4
4'-
4
4
4.
4'<
4
18" STANDARD
24" ARTERIAL
NOTES:
1. FORMS SHALL BE TRUE TO LINE AND GRADE
AND SECURELY STAKED.
2. EXPANSION JOINTS SHALL BE PLACED ADJACENT
TO CATCH BASINS.
3. EXPANSION JOINTS SHALL BE EVERY 10 FEET
AND DUMMY (CONSTRUCTION) JOINTS EVERY 5 FEET.
4. EXPANSION JOINTS SHALL HAVE 1/2" TO 5/8" WIDE
PREMOLDED JOINT FILLER.
5. CONCRETE SHALL BE CLASS 3- 30OOPSI.
6. FINISH SHALL BE LIGHT BROOM.
7. CURB SHALL BE SPRAYED WITH CLEAR CURING
COMPOUND OR SHALL BE COVERED AND KEPT MOIST
FOR 72 HOURS.
8. ALL SIDEWALKS POURED BEHIND CURB IN
DRIVEWAY AREAS SHALL BE 6" THICK OVER 2" OF
CSTC WITH SUBGRADE COMPACTED TO 95% MAXIMUM
DENSITY.
6"
5/8" MINUS CSTC
-TY
C.-I
REVISIONS
APPROVED BY DATE STANDARD DETAIL
D. GEBERT 4/27/05
STANDARD TYPE "A" CURB/GUTTER DETAIL
D, GE13ERT 4/2/07
DATE 7/24/01 SCALE NTS DWG NO. E2.8
Es . 0
DRAWN BY DESIGNED BY
KWP/TY AJS
CHECKED BY APPROVED 8)
TJE TJE
DATE
05/27/2015
JOB No. :114407
CURB AND GUTTER
NTS
2-
C3.01
6-
C4.01
WA
Call 811' 4
two business days 1601 5th Avenue, Suite 1600
before you dig Seattle, WA 98101
206.622.5822
www.kpff.com
27
-1P
IST
S C A L E:
IONAL
AS SHOWN
FLANGED AND BOLTS
UNDISTURBED EARTH CONNECTION
1 'xj X,
12'xl2'x4'
CONC. BLK.
HYDRANT CONNECTION PIPE TO
1x4'
BE DUCTILE IRON CLASS 52, ANY 12'x12
INTERMEDIATE JOINTS TO BE CONC, BILK,
.-fHRU�T
RESTRAINED BLOCK
NrITFS:
1. HYDRANTS AND ALL MATERIALS TO BE IN ACCORDANCE WITH CITY OF EDMONDS
APPROVED MATERIAL MODIFICATIONS LISTINGS.
2. CONSTRUCT 3� 3C X 3.5' THICKLICONCRETE PAD AROUND HYDRANT PIPE.
X
HYDRANTS SE IN ONCRETE REQ IRES AN EXPANSION STRIP AROUND HYDRANT BARREL. IN ADDITION,
THE INSTALLATION OF THE HYDRANT ON PRIVATE PROPERTY SHALL EQUAL OR EXCEED STANDARDS
SET FORTH FOR THE INSTALLATION OF PUBLIC FIRE HYDRANTS IN THE CITY OF EDMONDS.
3. ALL HYDRANTS SHALL HAVE A 6A BASE TRAFFIC MODEL PROVIDED WITH (2) 2-1/2' HOSE NOZZLES AND
(1) 4-1/2' NST PUMPER NOZZLE ITH 4' SYDRZ QUICK COUPLING ADAPTER,
4. PUMPER PORT SHALL FACE THE STREET OR ROADWAY FOR FIRE ENGINE ACCESS,
5. THREE FOOT MINIMUM LEVEL CLEARANCE SHALL BE MAINTAINED AROUND HYDRANT
WHEN PLACING LANDSCAPING.
6. FIRE HYDRANTS SHALL BE PAINTED SAFETY YELLOW BRAND, KELLY MOORE (1700-63 SUNBURST YELLOW)
7. RAISED PAVEMENT MARKER TO BE PLACED 4' FROM PAVEMENT C/L OR PAINTED LINE ON HYDRANT SIDE OF ROAD,
'D
-N
c .-Ty
REVISIONS
APPROVED BY DATE STANDARD DETAIL
D. GEBERT 6/16/03 FIRE HYDRANT ASSEMBLY
D. GEBERT 4/2/07 - DATE
Est. 1890 7/24/01 SCALE NTS DWG NO. E7.1
R. ENGLISH 10/04/11
FIRE HYDRANT ASSEMBLY
APPROVED FOR CONSTRUCTION
CITY OF EDMONDS
DATE:
BY-
4� �EN_G1N,4,,Nuny,,WoN
4--Cvfy
NTS
3-
C3.01
<
m
_j V)
< U)
_j 0
Or-- < 0
Ljj CL
>
Z LA
(n
§i�
(Q Z
00
U)
a- 0
U) t7j LL_
0
V) 0
< (3
C5
Z.
Ljj 0
V)
-Do
_J00
z
Ld
U) V)
(n
_j Ld
:;Fc _j Ld
c"I Off (n m
0
06
0
N
0
V)
_j
V) 0
_j
V)
1--
LL_
0
Uju)
0
0
z_j
E2
z
fn <
Ljj Z
2,0
_j
_j W
w
_10�1
< m
m
V)<C,4
(n _j
_j
0
<
L'j
'z
L'm
L<,
wo
w
V)
0
_j :r
< Ln
LEO Li �;
wo�- :2 Lt-
- _j W
_j :c
.9� <
-TY.
C.1
REVISIONS
APPROVED BY DATE STANDARD D ETAI L
ALUMINUM PEDESTRIAN HANDRAIL
1890-1990 DATE 7/24/01 SCALE NTS DWG NO. E8.8.1
PEDESTRIAN HANDRAIL
NTS
EDMOND11
SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS
in ILM
EDMONDS, WASHINGTON
SCHML
DISTRICT
RESUB
CITY OF EDMONDS DETAILS JUN 0 12015
BUILDING DEPARrMENT
CiTY OF EDMONDS
4
C4.01
SHEET
C7.02
I
E�
61-,
, "38'E 1319,95 REF.2 (1,319.94 N!, 131ku P) M.) K
'33,
, ' "ic
106'H-1 AVE. 10/. 1\1) 1;13 1") PROPERTY LINE (TYP)
CD 106TH AVENUE,,-,,
. . .............. ....... . ....... ....... ... .. .. ......... ..... . .............
- --------- A
x — ---------- - - ----------- 7
v7 x
X X
4e,
A
X
0I
.0
.0
)o
EXISTING VEGETATION Xt GETA11ON T
.. ..... ... .....
�S,
V
X
UJI J,
LLJ
M
---------- ------- 1:73
M
V------ ---------
=F 01
V SEVEN (7) EX. DOUGLAS
V FIR TREES TO BE REMOVED
EX 3" CALIPER DFrin
�k
!A,-
4. -0
.:a . 4-
:4- .01
4,
00,
4L A
+
F
F
X
x
RP
STATE OF
IWA S 14 1 N G,r o u
G T E R E
L6N AR I
RT rr,111*12. INC(, 1312.
1 1309
0
13
1% .0
2' F.
TYPE V DS,
992 S.F.L'�
7A
Q 00000
0000000
0 00000
000001
TH ENGINEEREE
9" DEP
CHIPS OVER 'NON
:21KILTER FABRICv�/CHIP;
To llopu
17PE v LANDSCAPE
296 S.F.
C2
-n
944"
A
EX. 3" CALIPER DECID.
TREE TO B REM D +
+
+ + t + + +
TREE BE EMO E V ANDS PE
4
V, Y
6 S.
-TYPE V LANDSCAPE
+ +
*
N
7
I
249 S.F.
E V ANDS PE
+
6
A6 F6.
TYP V L NDSC PE
.4,
'd - --A
5P WID14KSTiIAN ACCESS
t2o
111 tiMAIN LINN rLNUL
02
8' WIDE DOUBLE SWING
4, %
A:j 0 11.02
CF) 1. CHAIN LINK GATE---
7, -n F . ..............
j
-�x
;0I
0
-e
W �Iri - - - !,; e . .
Ipqlll
-011
Oil
0
*4r 10'I
- TO
'GATE'
'7
00,
+ + +
+ +
FLUS
+ + + + + +
+ + 4 +1 + +
56
E.9RB
+ + + + +
32'
+ + 4 + + + +
+ + 4 + + +
+
+ +
CONNECT NEW FENCE
TO EXISTING FENC�
O� CHAIN LINK FENCE
CREATE 5' WIDE
OPENINGS IN
EXISTING FENCE TO
ALLOW ADA ACCESS
TO FIELD
TYPE V LANDSCAPE
239 S. F.
CHAIN LINK FENCE Kl�
\L1.02/
CHAIN LINK GATE
\L1.02/
III
0
0
211-011
\Ll.UZ/
"I
NOTES:
1. PARKING AREA: CITY OF EDMONDS TYPE V LANDSCAPE PER
CHAPTER 20.13 LANDSCAPE REQUIREMENTS.
2. SEE SHEET L1.02 FOR PLANTING DETAILS.
3. SEE SHEET L2.01 FOR IRRIGATION LAYOUT PLAN.
PLANTSCHEDULE NOTE: SEE SHEET 1-1.02 FOR PLANTING DETAILS
Trees
QMQD Name.
WWORM
WM
Toe
I Uadu
lComments
Tschonoskii Crabapple
Malus7schonoskil"
2" ca 1,
'13
1 B&B
I asshown
Ispecimenform
Shrubs
cmmon.Name
Ldh—N-3-ft
size
Quant
Tylat-
SO
Comments
Otto Luyken Dwarf Cherry Laurel
Prunus laurocerasus 40tto Luyken'
I gal.
244
container
asshown
Ribes sanguineum
Red-floweringcurrent
1 gal.
30
container
36"o.c.
Rain Garden Zone 3
Symphoricarpos albus
Snowberry
1r gal.
45
container
36" o.c.
Rain Garden Zone 2
G Itheria shallon
Isaial
1 gal,
35
container
1 36" o.c.
lRain Garden Zone 3
HATCH SYMBOLS Grasses
Ir V V V
RAIN GARDEN ZONE 1 1++++++++
A A A A
RAIN GARDEN ZONE 2
RAIN GARDEN ZONE 3
Bromus carinatus
California Brcmetush
2" plug
190
2"plug
12" ax,
Rain Garden Zone 3
Festuca ovina'glauca'
Idaho Blue Fescue
4" pot
190
container
12" ci.c.
Rain Garden Zone 3
Festuca idahoensis
Idaho Fescue
4" pot
190
container
12" o.c.
Rain Garden Zone 3
Juncus effusus
Common Rusb
2" plug
290
2'"plug
12" o.c.
Rain Garden Zone 1
Juncus ensifolius
Daggerleaf Rush
2" plug
290
2" plug
12 O.C.
Rain Garden Zone 1
Juncus tenuis
Slender Rush
2" plug
600
2" plug
12 o.c.
Rain Garden Zones I & 2
Scirpus acutus;
Hardstern Bulrush
2" plug
290
2" plug
12" o.c.
Rain Garden Zone I
Hydroseed
X.
commian Nam
LaunAam
SM 1-9110111
1 I= I
512aaffll
lComments
Northwest Lawn MiX
N/A
N/A
I
9,914 s.f.
hydroseed
I
Seeding rate: 6
I lbs/1000 s.f,
160% Perennial Ryegrass, 20% Hard
I Fescue, 20% Kentucky Bluegrass
DRAWN BY DESIGNED BY
DAD DAD Call 811
CHECKED BY APPROVED BY two business days 1601 Sth Avenue, Suite 1600
DAD IGJ before you dig Seattle, WA 98101
DATE 206.622.5822
05/12/2015 S www.kpff.com
REVISION J 0 B No. :114407 AS SHOWN
N E S
105 SOUTH MAIN STREET
SUITE 300
SEATTLE, WASHINGTON
USA 98104
RELOCATEBACKSTOP Ell�l
LEGEND:
------------------
15+00 PROPERTY LINE
106TH ENUE
APPROXIMATE LIMIT OF CONSTRUC11ON
. ... .... - ......... . . .. . .. .................. EXTRUDED
CURB PER COE STI) E2.7
VERTICAL CURB PER COE STI) E2.10
-X
VEL P+ (TYP)
4" SOLID PAINTED STRIPE
-z -
X.
CURB WHEEL STOP
SAWCUT LINE
r
X�
CHAIN LINK FENCE
ADA PARKING SIGN
C/)
ADA PARKING SYMBOL
"N
MEOW=
TRAFFIC DIRECTIONAL ARROW
I
I t STOP BAR
CROSSWALKBAR
ir R1
A mba.—. J
CURB RAMP TYPE
EE
,.0 1 10 20 40
....................
.........................
1 inch = 20 feet ASPHALT PAVEMENT
........... ...............
CONCRETE. SIDEWALK PER COE STI) E2.13
SOUTH WEST ENTRANCE
SCALE: 1" 20' "NO PARKING" AREA
APPROVED FOR CONSTRUC11C
CITY OF EDMONDS
DATE:
EDMONDS[ qzLirowninin 1711 rkIrMTADV CPUnni TDArI711% AKin DrnrCTDIAKI CArrTV 1kJDDrwnArkITC qHFFT
ARCHITECTS
LANDSCAPE ARCHITECTS
PLANNERS
TEL 206.624.5702
FAX 206.624.5923
WWW.JONESANDJONES.COM SCH(0)L
DISTRICT
APPROVED AS NOTED
Date:,
-* 94+ItJ
EDMONDS, WASHINGTON
JUN 18 2015 Ll e0l
LANDSCAPE PLAN 13UILDING DEPARTMENT
CITY OF EDMONDS
BID DOCUMENTS
STATE OF
IWASHINGTOO
TREE PLANTING
IVY
;�3 1 -
I 1 110-
VEGETATION PROTECTION
wr m sm
0 w2vl� Mum
SHRUB PLANTING
DRAWN BY DESIGNED BY
DAD DAD
CHECKED BY APPROVED 8)
DAD
IGJ
DATE
05/12/2015
REVISION J 0 B No. :114407
TYPE 4
CHAIN LINK FENCE
PULL POST
TENSION WRE---,,
FABRIC FAN
Tffl
STRETCHER BAR
MIR)
WIRE
BOTTOM TENSION
HOG RINGS
SPACED @
24- MAX (TYP)
TENSION CABLE
TENSION
CABLES
GATE POST �TYP
3 1/2 0
(NOM, SCH 40)
WIDTHS VARIES
8'-0" AND 24'-0"
TIE WIRES (TYP)
SPACED
0 14" MAX
TRUSS ROD
(TYP)
MATCH FENCE
SELVAGE(TYP) TOP HINGE
180" SWING (TYP)
�//"v U
Y
BOTTOM HINGE
TCH FENCE
180- SWING (TYP)
7
CHAIN LINK FENCE FABRIC SELVAGE (TYP)
105 SOUTH MAIN STREET
SUITE 300
SEATTLE, WASHINGTON
USA 98104
12" ROUN
4A' kJAV
NOTES:
1 . ALL CONCRETE POST BASES SHALL BE 10" MINIMUM DIAMETER.
2. ALONG THE TOP AND BOTTOM, USING HOG RINGS, FASTEN THE
CHAIN LINK FENCE FABRIC TO THE TENSION WIRE AND TENSION
CABLE WITHIN THE LIMITS OF THE FIRST FULL FABRIC WEAVE.
3. DETAILS ARE ILLUSTRATIVE AND SHALL NOT LIMIT HARDWARE
DESIGN OR POST SELECTION OF ANY PARTICULAR FENCE TYPE.
ARCHITECTS
LANDSCAPE ARCHITECTS
PLANNERS
TEL 206.624.5702
FAX 206.624.5923
WWW.JONESANDJONES.COM
10, 0" (TYP.)
TENSION CABI F
TENSION
CABLES
HOG RINGS
SPACED @
24 MAX (TYP)
TYPE 4
CHAIN LINK FENCE
PULL POST
TENSION WIRE
48" HIGH CHAIN LINK GAT
PULLPOST
POS"r
FABRIC BAND
SPACED 15" MA
METHOD OF FASTENING
STRETCHER BAR TO POST
(SHOWN FOR ROUND POST)
48" HIGH CHAIN LINK FENCING
JAX
4CE
3 T
APPROVED FOR CONSTRUCTI
CITY OF EDMONDS
DATE:
BY.
EDMONDI SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS
EDMONDS, WASHINGTON
SCH(0)L
D I ST R I C T
RESUB
JUN 18 2015
LANDSCAPE DETAILS
BUILDING DEPARTMENT
CITY OF EDMONDS
SHEET
Ll e02
2m
. . . . . . . . . J J . .
of
or 'F
dr
7-7, / - J* - . o . ./ I. -/ �X- -X
61
'o
4,
A
01
IF
L/ '00,
01.
-�X
ZX A
oo,
4
dr
40, .
8 x. -�X- +
+ + + + + + + + + + +
.33 !A 8 8 10 . . . . . . .
Id
A" . . . . . . .
8 . . . . . . .
8 10 . . . . . .
8 . . . . . . . 0
+
X. -X + +
+ . . .
1-2
12 A
A A:4
3/4W
A
A
3
2d A
'A K! j
A A
4, 8 3
Kos
'w
8
;I A-
1v 0
42
'j,
A
10 0
j
A CUT AND SPHALT::
D TO INSTALL NEW VALVE + + + +
+ + +
2 PIPE, AND SLEEVES. + + + + +
A
+ + +
+ + + + + +
+
Y2 + . . . . . .
. . . . . . . + SEE SHEETS C1 AND C2 FOR RELOCATING
V" + . . . . . . EXISTING FIELD SPRINKLER HEADS,
+ + + + + + + + + + + + + + + THIS AREA.
2') + . . . . . . .
A
+
4. 41. 46 4.
'o
'. - �� n�4��
CONNECT TO MAIN LINE AT EXISTING VALVE. USE SPARE (RED)
WIRE IN EXISTING BOX TO CONNECT NEW VALVE TO SYSTEM. IF THIS SPARE
IS NON -WORKING, INSTALL TUCOR HYBRID 3D UNIT AND DECODER,
PER THE ADD. ALT.
7111 IRRIGATION SCHEDULE
... ............. ...........
0
T �1.
0
M
C-D a-
U5 ,
W —
M
5
TURF POP UP HEAD.
5-1 En
is J..
M
z
1/2" MARLEX STREET ELL. —
BARB ELL X MIPT.
A)
204
1/2" MARLEX
en
STRE ELL.
U.1
C= U)
W
E
C.)
E PVC TEE (SXSXT)
OR ELL.
LATERAL LINE.
C-)
>1
(n
E
I
> <
co E
NO.
DATE
4 4
a
4" - I
TO CURB OR
WALK.
1/2" POLYETHYLENE FLEXIBLE
TUBING, LENGTH AS REQUIRED.
ME
a)
11
4=
0 JUMBO VALVE BOX
n2 FINISH GRADE
REMOTE CONTROL VALVE
MODEL PER PLAN
WATERPROOF CONNECTORS (2)
18-24" COILED WIRE
SCH 80 T.O.E. NIPPLE
SCH 80 NIPPLE
MAIN LINE PIPE & FITTINGS
3/4" MINUS WASHED GRAVEL
PVC SLIP UNIONS
BRONZE GATE VALVE
REMOTE CONTROL VALVE WITH S.O.V.
328403.13-03 NTS 328406.13-08
DRAWN BY DESIGNED BY
KWP/TY AJS
Call 811
two business days
before you dig
.1601 Sth Avenue, SL1i1Q1 1600
Sea, tie, �A)A 99101
c�
2 0 6. 6 2 2. 5'Q�2 "I
CHECKED BY -APPROVED BY
TJE TJE
DATE
05/12/2015
S C A L E:
AS SHOWN
J 0 B No. :114407
BY
CHID.
APPR.
REVISION
NOTES:
1 THIS IS AN EXTENSION OF THE EXISTING IRRIGATION SYSTEM.
THERE IS AN UN —USED RED WIRE IN THE EXISTING VALVE BOX
JUST EAST OF THE NEW DRIVEWAY. TEST AND VERIFY ITS
SUITABILITY FOR USE WITH THE NEW CONTROL VALVE. IF IT IS
NOT SUITABLE, INFORM THE OWNER'S REPRESENTATIVE
IMMEDIATELY. INSTALL THE TUCOR 3D HYBRID UNIT PER THE
ADD. ALT.
2. SYSTEM DESIGN ASSUMES A MINIMUM STATIC PRESSURE OF 50
PSI AND A 2" POINT OF CONNECTION. VERIFY IN FIELD.
3. PLAN IS DIAGRAMMATIC ONLY. ADJUST EQUIPMENT LAYOUT
AND NOZZLES SO AS TO AVOID OVER SPRAY ONTO BUILDINGS,
PAVED SURFACES, AND DIFFERING HYDROZONES, WHILE
MAINTAINING 100% (HEAD —TO —HEAD) COVERAGE.
4. VERIFY ALL DIMENSIONS AND SITE CONDITIONS IN FIELD.
VALVE SCHEDULE
NUMBER MODEL SIZE TYPE PSI PSI(cD-POC GPM PRECIP
1 Rain Bird EFB-CP-R T--10 ShrubSpray 38.39 36.65 1.55 in/h
Unknown Existing Valve ill 5.00 0.00 Unknown
SYMBOL
MANUFACTURER/MODEUDESCRIPTION
1l, 0 0
Rain Bird 1806-SAM 5 Series MPR
0 H F
Shrub Spray 6.0" Pop -Up Sprinkler with Co -Molded Wiper Seal.
1/2" NPT Female Threaded Inlet. With Seal-A-Matic Check
Valve.
0 0 0 0
Rain Bird 1806-SAM 8 Series MPR
0 T H F
Shrub Spray 6.0" Pop -Up Sprinkler with Co -Molded Wiper Seal.
1/2" NPT Female Threaded Inlet. With Seal-A-Matic Check
Valve.
0 DOG
Rain Bird 1806-SAM 10 Series MPR
0 T H F
Shrub Spray 6.0" Pop -Up Sprinkler with Co -Molded Wiper Seal.
1/2" NPT Female Threaded Inlet. With Seal-A-Matic Check
Valve.
0 e00(D
Rain Bird 1806-SAM 12 Series MIPR
0 T H TQ F
Shrub Spray 6.0" Pop -Up Sprinkler with Co -Molded Wiper Seal.
1/2" NPT Female Threaded Inlet. With Seal-A-Matic Check
Valve.
08HE-VAN Q12 12HE-VAN
1 OHE-VAN (L5) 15HE-VAN
Rain Bird 1806-SAM ADJ
Shrub Spray 6.0" Pop -Up Sprinkler with Co -Molded Wiper Seal.
1/2" NIPT Female Threaded Inlet. With Seal-A-Matic Check
Valve.
SYMBOL
MIANUFACTURER/MODEUDESCRIPTION
Existing Valve
Brass valve in plastic box, in pavement.
K\
\JIF
Rain Bird EFB-CP-R
1", 1-1/4", 1-1/2", 2" Brass Remote Control Valve, Contamination
Proof w/Self-Flushing Filter Screen. Globe Configuration.
Quick -Coupling Valve -Existing
V.
Gate Valve -Existing
Pressure Reducing Valve -Existing
Febco 805Y-Existing 1"
Existing Double Check Valve Assembly, 2"
MC
Controller --Existing
Rain Bird ESP-24 in steel enclosure.
Tucor Hybrid 31D
Additive Alternative. 2-wire decoder accessory for any
controller. Allows installation of addtional control valves without
installing addtional wire back to the controller.
Irrigation Lateral Line: PVC Schedule 40
PVC Schedule 40 irrigation pipe.
Irrigation Mainline: Existing Main Line
Presumed location. 2" PVC (size assumed).
0 10 20 40
1 inch = 20 feet
am* W"M flow Pipe Sleeve: PVC Schedule 40 APPROVED FOR CONSTRL
volve callout CITY OF EDMONDS
Valve Number
Volvo now DATE -
Valve Size BY.-_
EDMONDS. i cprownrin 1171 rkJC*MTADV 4Z(Wr)AI TOA17rl(' Amn Prn1:lZTP1AM IZA971:TY IMPP0V1:M17WTq SHEET
EDMONDS, WASHINGTON
SCHML
D1 S T R I C T
RESUB L2o01
IRRIGATION PLAN JUN 18 2015
BUILDING DEPARTMENT
CITY OF EDMONDS BID DOCUMENTS
m
LLJ
(n
0
C-)
E
Z E
cn
M
K:)n
cn
0-
E
-2
co 0
0
(D
E
C:)
0
E
.
c:,
p
SP_ I
LL.j
E
CL
00
q- V)
> I <
U-) as
3 E
C'4
Do
C,4
(D
X
G- - x
— ------- 4— 16
7—L-j"
-4
1
--77. 77 j,—.-
1 2
lip
F2
C)
T,
5
�3 4
2 3
p
LUMINAIRE POLE SCHEDULE
LUMINAIRE
LOCATION — BASELINE
MOUNTING
WATTAGE
CIRCUIT
COMMENT
POLE NO.
106TH AVE W
HEIGHT
STA 14+90.6,
39 FT
139
1
BACK—TO—BACK
1
8 6.5' RT
39 FT
139
FIXTURE
STA 16+11.2,
39 FT
139
1
BACK—TO—BACK
2
119.8' RT
39 FT
139
FIXTURE
3
STA 15 + 9 7.6,
30 Ft
139
1
272.7' RT
4
EXISTING
EXISTING
139
1
REPLACE FIXTURE
ON EXISTING POLE
5
STA 17+14.9,
39 Ft
139
1
73. 1' RT
6
STA 18+22.4,
30 Ft
139
1
138.7' RT
7
STA 18+33.4,
30 Ft
139
1
5 5.6' RT
8
STA 19+54.0,
30 Ft
139
I
1
131.0' RT
9
EXISTING
EXISTING
139
1
REPLACE FIXTURE
ON EXISTING POLE
10
STA 20+63.5,
30 Ft
139
I
i I
130.8' RT
I
SEC36 T27N R3E W.M.
V
-G
47
00 I-Q& T1H -------
17
21; AVE 18+00 BASELINE
6T�
H AVE W
",19+00
20+oo
777=7-7
777
3-
=77
d
9 7
4 5
+
17
12
A
41M.
71 4�
,2
SD ---
9 31
SID
zi�
al�u-
4
JI
SD
2 10
CONSTRUCTION NOTES
(D INSTALL CREE XSP SERIES I-ED BACK-TO-BACK LUMINAIRES (BXSP-C-HT-3ME-F-40K-UL-SV-R) WITH
PHOTOCELL ON PT-2(180) MOUNTING BRACKET AT 39FT MOUNTING HEIGHT, ON ROUND STEEL COOPER
LIGHTING POLE (RTS9D39S) OR APPROVED EQUAL, ON FOUNDATION PER WSDOT STANDARD PLAN
J-28.30.
INSTALL CREE XSP SERIES LED LUMINAIRE (BXSP-C-H'1--3ME-F-40K-UL-SV-R) WITH PHOTOCELL ON
XA-TMDA8 MOUNTING BRACKET AT 3OFT MOUNTING HEIGHT, ON ROUND STEEL COOPER LIGHTING POLE
(RTS8A30S) OR APPROVED EQUAL, ON FOUNDATION PER WSDOT STANDARD PLAN J-28.30.
REMOVE EXISTING FIXTURE FROM EXISTING LUMINAIRE ARM. INSTALL CREE XSP SERIES LED LUMINAIRE
(BXSP-C-HT-3ME-F-40K-UL-SV-R) WITH PHOTOCELL ON XA-TMDA8 MOUNTING BRACKET AT EXISTING
MOUNTING HEIGHT.
INSTALL CREE XSP SERIES LED LUMINAIRE (BXSP-C-HT-4-ME-F-40K-UL-SV-R) WITH PHOTOCELL WITH
XA-TMDA8 MOUNTING BRACKET AT 39FT MOUNTING HEIGHT, ON ROUND STEEL COOPER LIGHTING POLE
(RTS9D39S) OR APPROVED EQUAL, ON FOUNDATION PER WSDOT STANDARD PLAN J-28.30.
CONNECT TO EXISTING SERVICE POINT TO REMAIN. INTERCEPT EXISTING CONDUIT INTO BUILDING AND
POWER SUPPLY WITH NEW CONDUIT IN AREA OF PROPOSED IMPROVEMENTS. TERMINATE NEW
CONDUCTORS ON EXISTING PANEL IN BUILDING. I -
INTERCEPT EXISTING CONDUIT AT FOUNDATION BASE WITH NEW CONDUIT AND RUN NEW CONDUCTORS TO
NEW FIXTURE ON EXISTING POLE.
f�W C,6XCrd4 oa&�, &-�kjc- , 5&� 4�-� U)-'�POT
WIRING SCHEDULE
N 0
21d
RACEWAY CONDUIT SIZE*
CONDUCTOR
COMMENTS
1
2" SCH 80
2—#8
2
EXISTING
EXISTING
*ALL NEW CONDUIT SHALL BE PVC AND SHALL CONTAIN A NO. 8 GROUND
WIRE, UNLESS OTHERWISE NOTED.
q
q\-r
GENERAL NOTES
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CITY OF EDMONDS
-1:i iv
STANDARD DETAILS, AND THE WASHINGTON STATE DEPARTMENT OF
TRANSPORTATION (WSDOT) STANDARDS AND SPECIFICATIONS.
2. LUMINAIRE LOCATIONS SHALL FOLLOW WSDOT STANDARD PLAN J-28.26-01 AND
SHALL BE APPROVED BY THE ENGINEER PRIOR TO FOUNDATION EXCAVATION.
77T
\2.
3. CONTRACTOR SHALL VERIFY UTILITY LOCATIONS AT POLE FOUNDATIONS PRIOR TO
SUBMITTING MATERIALS. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE
CITY FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE.
4. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED
IN THE FIELD BY THE CONTRACTOR PRIOR TO CONSTRUCTION WORK.
I i4l 5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE
CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS PRIOR
TO COMMENCING WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY
If AGENCIES THROUGHOUT THE PROJECT.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING
UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND
THE CITY IMMEDIATELY UPON DAMAGE AND BE RESPONSIBLE FOR REPLACING ANY
DAMAGED EQUIPMENT TO THE SATISFACTION OF THE AFFECTED UTILITY COMPANY
AND/OR THE CITY.
7. TYPE 1 AND 2 JUNCTION BOXES SHALL BE INSTALLED PER WSDOT STANDARD
PLAN J-40.10-02. JUNCTION BOXES SHALL BE LOCATED WITHIN 5FT OF
LUMINAIRE POLES WHEN FEASIBLE AND SHALL HAVE "NON—SKID" LIDS WHEN
PLACED IN THE SIDEWALK.
8. NEW ILLUMINATION EQUIPMENT COLORS TO MATCH EXISTING ILLUMINATION
EQUIPMENT TO REMAIN.
LEGEND
00
c\j SYMBOL DESCRIPTION
c\j
R/W LINE
PROPOSED LUMINAIRE
AND POLE
PROPOSED LUMINAIRE
ON EXISTING POLE
CONSTRUCTION NOTE
A# WIRE NOTE
LUMINAIRE POLE NUMBER
CONDUIT
-bpi"
TYPE 1 JUNCTION BOX
TYPE 2 JUNCTION BOX
SERVICE CABINET BREAKER SCHEDULE
CIRCUIT
BREAKER
CONTACTOR
LOAD
VOLTAGE
DIRECTORY
SIZE
SIZE
ILLUMINATION
20A (EX.)
EX.
1,668W
240V
CIRCUIT 1
APPROVED FOR CONSTRUCTION
CITY OF EDMONDS
DATE:
BY:
CALL 48 HOURS
BEFORE YOU DIG
1-800-424-5555
DRAWN BY DESIGNED BY V IE EDMONDI SHERWOOD ELEMENTARY SCHOOL TRAFFIC AND PEDESTRIAN SAFETY IMPROVEMENTS SHEET
Jzp Jzp .. S -,o%up V=
CHECKED BY APPROVED BY Call 811 vanspogm EDMONDS, WASHINGTON
RWP RWP two business days C-1) WHAT TRANSPORTATION CAN BE.
DATE before you dig RESUM IL1 .01
05/28/2015 6 11730 11 8TH AVENUE NE, SUITE 600 (TEL) 425 821-3665 JUN 0 1. 2015
S C A L E: L KIRKLAND, WASHINGTON 98034 (FAX) 425 825-8434 ILLUMINATION P LAN BUILDING DEPARTMENT
JOB No. :114407 SCH(M CIV OF EDMONDS
N 0. DATE E3Y CHD. APPR. REVISION AS SHOWN DISTRICT FOR PERMIT
EDGE OF
TRAVELED WAY
10.0' MIN.
;HOULDER 3.9 MIN.
HAND HOLE
FIXED B I ASE VARIES (1.6 MAX)
NOT STEEPER
THAN 2H:1V
STEEL LIGHT
STANDARD
F U I
70UNDATIONI.-
SECTION VIEW
CASE I
POSTED SPEED LIMIT LESS THAN 35 MPH
VARIES WITH
OFFSET DISTANCE 3 ' 0'
3.0' MIN. MIN.
EDGEOF HAND HOLE
SHOULDER -Z_ I.H�I'VSLOPE
OR TTER
SLIP BASE SLOPE ROUNDING
NOT STEEPER THAN 4H:1V
10HAVSLOPE
OR FLATTER
FILL MATERIAL
STEEL LIGHT
STANDARD
FOUNDATION ?
SEC71ON VIEW
CASE K
ROADWAYS WITH 10H:1V
OR FLATTER SIDE SLOPES
EDGE OF SHOULDE
I FACE OF CUS
NOTES
VARIES - DEPENDS 1. See Standard Plan J-28.30 for foundation details
ON JURISDICTION
(SEE CONTRACT) and construction methods.
2See Standard Plan J-28 50 for Dole base and
hand hole details.
NOT STEEPER
THAN 2HAV
SECTIONVIEW
CASE J
POSTED SPEED LIMIT LESS THAN 35 MPH
FIXED BASE
STEEL LIGHT
STANDARD47:
FOUNDATION
SECTION VIEW
CASE L
PARKING LOTS
J Iq i 7 20115
ul
My OF EWX�JIJ3
HAND HOLE
PAVEMEN T
W N
LU
, S
OY WA
Jill,
NN
00 f�, 25335
HIE
01 STEt C3
x/
0 AL
STEEL LIGHT STANDARD
PLACEMENT
MISCELLANEOUS
STANDARD PLAN J-28.26-01
SHEET: I OF 1 SHEET
APPROVED FOR PUBLICATION
Pasco Bakodch N 12-02-08
D-GN ENGLN� mm
50 W-hi.gt- Sm. D.p.�nl d T—p�fl.fl-
GROUNDING CONDUCTOR - NOWINSULATED
#4 AWG STRANDED COPPER - PROVIDE
3' - 0- MIN. SLACK (ROUTE CONDUCTOR
TO LUMINAIRE GROUNDING STUD)
3"[1N) DIAM. x 314* (IN)
I GROUTWELL(TYP.)
'Tel
ANCHOI BOLT (TYP.)
SEE TABLE
HEAVY HEX
NUT (TYPj
�Iz. — Z
ANCHORBOLT-
SEE TABLE
CONDUIT COUPLING - INSTALL
FLUSH WITH TOP OF BARRIER
(DO NOT GLUE PVC STUBOUT)
SEE FIXED BASE FOR DETAILS NOT SHOWN
PARTIAL ELEVATION VIEW
SLIP BASE
ISOMETRIC VIEW
ANCHOR BOLT ASSEMBLY
(SLIP BASE SHOWN)
ANCHOR BOLT TABLE
ROUND WASHER SIZE TO
MATCH ANCHOR BOLT
(TYP.) - SEE TABLE
RAP TEMPLATE
SEMBLY(TYP.)-
E DETAIL
ANCHOR BOLT (TYP.) -
SEE TABLE
(D - 1/16"(IN)) DIAM.
HOLE (TYP.) -
SEETABLE
1/4' (IN) STEEL BAR (NP.) -
r (IN) WIDE x V- 3" LONG
LUMINAIRE
MAST
ARM
ANCHORBOL
iElGHT(FT)
ARM
LENGTH
DIAMETER (IN
(HI)
TYPE
"D'
(FT)
2V TO 50'
SINGLE
V To 1w
1.
20'TO 50'
DOUBLE
TTO S'
1.
2T TO 45'
DOUBLE
10'TO 16'
1.
46-To5o,
F DOUBLE
1VTO16-
1118-
314- (IN) CHANIFER (TYP.)
#7REINFORCING
STEEL BAR
#4 REINFORCING
STEEL HOOP
1 - (IN) DIAM. CONDUIT - CAP EACH
END - PROVIDE ADDITIONAL CON-
DUIT FOR COMMUNICATION OR
SIGNAL CABLE WHERE SHOWN
IN THE CONTRACT
EXTEND THE CONDUIT 6' (IN) MIN.
BEYOND THE FOUNDATION OR THE
CONTROI I ED-DENSITY BACKFILL
#4 HOOP (TYP.)
CLAMP CONDUCTOR To STEEL
REINFORCING BAR WITH LISTED
CONNECTOR SUITABLE FOR
USE EMBEDDED IN CONCRETE
CONCRETE CLASS 4000P
#7 (TYP.)
1, . 1"Cryp.)
TOP VIEW
STRAP TEMPLATE ASSEMBLY
TOP VIEW
FIXED BASE
I I . � I I
rt-.-tt
44
11
EIGHT #7 BARS,
EVENLY SPACED
CENTER THE CONDUIT
IN THE FOUNDATION
V- 3* DIAM. BOLT
MIRCLE (TYP.)
3/4' (IN)
CHAMFER (TYP.)
0
09
go
8
a.
W
11 U q
@ -d
IL IL U)
0 0 W
0 0 to
U W Z
M M W
W
>
ic
W
2 1/2" CUR
SEE SUP BASE FOR DETAILS NOT SHOWN
ELEVATION VIEW
FIXED BASE
NOTES
1. See Standard Plan J-28AO for Luminaire Pole base mounting details.
2. The Strap Templates shall be held in place by nuts, 6" (in) from the top of the foundation
and 3' (in) from the bottom of the anchor bolts. Eighteen heavy duty hex nuts and six
r?und washers are required for a slip base assembly. Eighteen heavy duty hex nuts and
six plate washers are required for a fixed base assembly.
3. Use Steel Light Standard Foundation Type A on level ground or slopes not ekeeding
4H : IV. Use Type B for slopes steeper than 4H : IV, but not exceeding 2H : IV.
Slopes steeper than 2H , IV shall require a special design.
4. These foundations are designed for a minimum of 2000 PSF (TYPE A) or 1500 PSF
(TYPE B) allowable lateral bearing pressure for the soil. A special foundation shall be
required for soil with allowable lateral bearing pressure lower than 1500 PSF.
5. The Luminaire Pole height shall, not exceed 50' (ft) (HI).
6. Slip bases shall not be installed on 50'(ft) (H1) poles with Double Mast Arms, nor on
poles weighing more than 1000 lbs.
7. Slip bases are required on poles installed inside the Design Clear Zone, and on poles
installed behind traffic barrier that are within the traffic barrier defection zone.
8. Foundations constructed within Media Filter Drains shall be increased in depth by
the depth of the Media Filter Drain.
9. Exposed portions of the foundation shall be formed to create a Class 2 surface finish.
All forming shall be removed upon completion of foundation construction.
10. For excavation, concrete placement, and backfill options, see METHOD I and
METHOD 2 on Sheet 2 of 2.
11. The anchor bolts *hall be high -strength steel, manufactured from ASTM F1554 Grade
105, with heavy hex nuts and hardened washers. Galvanize the anchor bolts according
to ASTM F2329.
12. The foundation shall be grounded in accordance with the requirements of
Standard Specification B-20.3(4).
13. See Standard Plans C-8b and C-85.14 for steel light standards on traffic barrier.
0
i 0 - uk.
0
2S470
SLIP BASE x — .
Zeldenrust, Richard
lun 1112014 111:11 ANI
X
STEEL LIGHT STANDAR
FOUNDATION TYPES A & B
STANDARD PLAN J-28.30-03
FIXED BASE SHEET I OF 2 SHEETS
-iOprPOLT LAYOUT APPROVED FOR PUBLICATION
pCt
12
ha 1110141:33 I'M
,7 ?nlq
;JUN
- L
D E V E LO P M-E! N F CR i _�� I :'; i i t" i
CITY OF ED%1i01$1D3
EDGE OF
EDGE OF
SHOULDER
LUMINAIRE POLE
SHOULDER
<
POLE BASE
POLE BASE
SLOPE ROUNDING
EMBANKMENT
WIDENING
UNDISTURBEDSOIL
;11z� UNDISTURBED SOIL
03
(TYP
(TYP-)
SLOPE 2H: 1V (MAX.)
(TYP-)
W tu
OR FLATTER
LIGHT STANDARD
Luita
METAL FORM FOR LIGHT
FOUNDATION
CONCRETE CLASS 4000P
STANDARD FOUNDATION
UUNUKtiECLASS 4000P
X
IN
QMW
UNDISTURBED SOIL
1 -0.
T-O'DIAM.
P.)
(CASEA SHOWN)
METHOD-1
NO SUBSURFACE FORM
This option is used only when the existing soil in the hole Vill
remain standing and the cement concrete can be placed with-
out causing the soil to collapse. Concrete shall be cast directly
against undisturbed soil.
Auger the hole for the foundation. Use a paper or cardboard form
to achieve a smooth finish on the final exposed cement concrete.
Support the form as necessary to remain plumb.
See Standard Plans J-28.24 and J-28.26 for maximum heights
of exposed foundation when no embankment widening is to be
installed.
Place the concrete foundation.
After concrete has cured, remove the paper or cardboard
form portion.
Construct the embankment widening (if required).
NOTE
These foundation Construction Methods
are applicable to all Steel Light Standard
Placement Cases. See Standard Plans
J-28.22, J-28.24, and J-28.26.
LUMINAIREPOLE
6,SLOPE ROUNDING
EMBANKMENT
WIDENING
SLOPE 2H: 1V (MAX.)
OR FLATTER
TEMPORARY SLOPE OR
SHORE AS REQUIRED (TYP.)
OVER -EXCAVATED AREA SHALL BE BACKFILLED
WITH CONTROLLED -DENSITY FILL (CDF), OR WITH
COMPACTED BORROW IN ACCORDANCE WITH
STANDARD SPECIFICATION B-20.3(2)
LIMITS OF STRUCTURE
EXCAVATION
UNDISTURSEDSOIL
(CASE A SHOWN)
METHOD 2
METAL (SUBSURFACE) FORM REQUIRED
When the existing soil will not retain a vertical face, over -excavate
the foundation area and Install a 36" (in) diameter corrugated metal
(pipe) form. The corrugated metal form shall not extend more than
5" (in) +/- V (in) below any portion of the foundation that will remain
exposed upon final grading. Continue forming to full height using a
paper or cardboard form to achieve a smooth finish on final exposed
cement concrete. Support the form as necessary to remain plumb.
See Standard Plans J-28.24 and J-28.26 for maximurn heights
of exposed foundation when no embankment widening Is to be
installed.
Place the concrete foundation.
After concrete has cured, remove the paper or cardboard
form portion.
Backfill with controlled -density fill or compacted borrow in acco—
ance with Standard Specification 8-20.3(2).
Construct the embankment widening (if required)..
CONSTRUCTION METHODS
IJUN i 7 2015
-f �7!�N -
D'2-IELOF'i,,�EN: I -- 0-;ii I,; E3, C Rt
C11Y OF EO,�'4'011'-M
nV. VAAS1j,' 1
'&A
254?0
AL
Zeldenrust. Richurd
.4"/
Jun 10 2014 10:38 ANI
STEEL LIGHT STANDARD
FOUNDATION TYPES A & B
STANDARD PLAN J-28.30-03
SHEET20F2SHEETS
APPROVED FOR PUBLICATION
W lich, 11 ..
1.�71 1' 14 1:.1.1 IN
—M W�
VT,'p W.,higf.. StW. D paA.W.fT..g.�i-