Seattle Fire Department
Confidence Test Report
206-386-1448 Confidence Testing Officer
206--615-1068 (fax)
206-233-7219 Red Tag Hotline
STANDPIPE' SYSTEM
(One System per Report)
Certification Given
RED 1:1
YELLOW Ll
I WHITE 0
CONFIDENCE TEST z REPAIRS El
Occupancy Address: 23015 EDMONDS Occupancy Name: SEQUOYAH CONDOMINIUMS
WAY.EDMONDS
Building Owner: HOA Phone Number: SAME
Responsible Person: BRAD Phone Number: 4252752189
Building Owner Address: SAME
Date of Inspection: 10-19-9 Inspection Frequency/Type: Z 5 year
Testers Name
(Please Pr ' int): JIM FRY SFD Certification Number: SCP-F248
Number of Bldg. Stories 3 Location of FID Connection: BY WEST ENTRY
Primary Component: Standpipe System Make: NA
System Model:. NA
System Location: WEST STAIRS Identification Number:' BUILDING A
PROBLEMs FoUND: (If additional roorri is needed, please add a separate sheet)
NONE
.CokRECTIONs MADE: Dat6 Corrected: Corrected By:
(If additional room is needed, please add a separate sheet) SFD Certification Number: SCIP -
NONE
This certifies that this fire and life safety system has been properly inspected forieliability to cover the
Items listed in this report and is consistent with Seattle Fire Department Fire Code standards, and that
discrepancies are noted and have been reported to the building Owner/Manager for corrective action.
Signature of Tester: Phone# 2062415909
Testing Agency: A-1 FIRE EQUIPMENT
Mailing Address: 1002 NORTH CENTRAL, KENT
Building Representative (signature)
Page I of 4
The items on the checklists below shall be inspected and tested. This list does not constitute all of the
required inspecting and testing of the fire and life safety system. Refer to the Seattle Fire
Department
Fire Code for inspecting and testing requirements.
General
1 . Is there 300 GPM flow at roof through each riser? N/A
Yes
El
No El
2. All.fire department inlets and outlets equipped with approved plugs or caps (1/8
Yes
Z
No 0
inch pressure relief hole in.caps)?
3. Piping between fire department connection and check valve is currently hydro-
.
Yes
El
No E]
tested?
4. All control valves left in open position (except normally closed valves)?
Yes
Z
No El
5. Pumper connections are not obstructed?
Yes
Z
No D
6. Water flow switches operate properly? N/A Z
Yes
El
No El
7. Fire pump(s) start from roof flow? N/A El
Yes
El
No El
8. Was the Fire Department Connection (FDC) back flushed?
Yes
Z
No 0
9. Are there hose cabinets in the building?
Yes
El
No Z
10. Is the building sprinklered?
Yes
E-1
No Z
11. Standpipe Classification
12. Class I Standpipe?
Yes
Z
No El
13. Class 11 Standpipe?
Yes
El
No Z
14. Class III Standpipe?
Yes
El
No Z
15. Hose cabinet and/or sprinkler PRV testing form for each system? N/A
Yes
El
No El
16. Was debris found in the Fire Department Connection (FDC)?
Yes
El
No M
1.7. System gauges replaced every,�, years or calibrated?
Yes
El
No El
Class I
18. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours (Dry
Yes
Z
No El
Standpipe Only)
19. All outlet valves and hose threads checked and have 2 1/2" Cap w/l/8" hole?
Yes
Z
No El
20. Was 25 psi air test conducted?
Yes-
El
No Z
21. Standpipes have 12" wrench clearance?
Yes
Z
No 0
Class 11
22. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours:
Yes
Ej
No El
23. Are all hoses, valves and controlling nozzles in good condition?
Yes
[]
No El
24. Have flow tes ts been conducted at highest level for at least 30 seconds to make
Yes
Ej
No El
sure nozzle will work at pressure available (50 gpm at 35 psi minimum)?
25. Standpipe has 12" wrench clearance?
Yes
El
No El
26. Have controlling valves been tested to verify that pressure regulating valves
Yes
El
No El
operate properly (not to exceed 100 psi Tip pressure)?
Class III
27. Hydro -tested at 150 psi or 50 . psi greater than highest Operating pressure?
Yes
El
No El
28. Was 25 psi air test conducted?
Yes
El
No El
29. All outlet valves and hose threads.checked and have 2 1/2" Cap w/l/8" hole?
Yes
Ej
No 0
30. Flow tests conducted to verify operating pressure of press Regulating valves (not
Yes
No El
to exceed 175-psi flowing)?
Page 2 of 4
130,
SRI- 15QUIPMEl
N T.
INC
Seattle Fire Department
Confidence Test Report
206-386-1448 Confidence Testing Officer
206-61*5-1068 (fax)
206-233-7219 Red Tag Hotline
STANDPIPE SYSTEM
Certification 'Given
.(One System per Report)
RED El
I YELLOW 0
I'WHITE+ 2
CONFIDENCE TEST z REPAIRS 0
Occupancy Address: 23015 EDMONDS Occupancy Name: SEQUOYAH CONDOMINIUMS
WAY.EDMONDS
Building Owner: HOA Phone Number: SAME
Responsible Person: BRAD PhoneNumber: 425 275.2189
Building Owner Address: SAME
Date of Inspection: 10-19-9 Inspection Frequency/Type: Z 5 year
Testers Name
(Please Print): JIM FRY SFD Certification Number: SCP-F248
Number of Bldg. Stories 3 Location of FD Connection: BY EAST ENTRY
P�rimary Component:' Standpipe System Make: NA.
5yst6m Model: NA
Syst . em Location: EAST STAIRS Identification Number: + BUILDING A
PROBLEMs FoUND: (If additional room is needed, please add a separate sheet)
NONE
CORRECTIONSAADE: Date Corrected: Corrected By:
('If- - ala�-hional room is-n�eded, please add a separate sheet) SFD Certification Number: SCP -
NONE
This certifies that this fire and life safety system has been properly inspected for reliability to cover the
Items listed in this report and is consistent with Seattle Fire Department Fire Code s.tapdards, and that
discrepancies are noted and have been reported to the building Owner/Manager for corrective action.
Signature of Tester: Phone # . 206241 5909
Testing Agency: A-1 FIRE EQUIPMENT
Mailing Address: 1002 NORTH CENTRAL, KENT
Building Representative (signature)
Page I of 4
The items on the checklists below shall be inspected and tested. This list does not constitute all of the
required inspecting and testing of the fire and life safety system. Refer to the Seattle Fire Department
Fire Code for inspecting and testing requirements.
General
1 . Is there . 300 GPM flow at roof through each riser?, N/A Z
Yes
No [I,
2. All fire depart . ment inlets and outlets equipped with approved plugs or caps (1/8
Yes Z"
No 0
inch pressure relief hole in caps)?
3. Piping 'between fire department connection and check valve is currently hydro-
Yes El
No 0
tested?
4. All control valves left in open position (except normally closed valves)?
Yes Z
No El
5. Pumper connections are not obstructed?
Yes Z
NoE]
6. Water flow switches operate properly? N/A Z
Yes El
No D
7. Fire pump(s) start from roof flow? N/A 0
Yes El
NoEl
8. Was the Fire Department Connection (FDC) back flushed?
Yes Z
No El
9. Are there hose cabinets in the building?
Yes El
No 0
10. Is the building sprinklered?
Yes El
No Z
11. Standpipe Classification
12. Class I Standpipe?
Yes Z
No El
13. Class 11 Standpipe?
Yes El
No Z
14. Class III Standpipe?
Yes El
No Z.
15. Hose cabinet and/or sprinkler PRV t6stingform for each system? N/A. 0
Yes El
No El
16. Was'debris found in the Fire Department Connection (FDC)?
Yes El
NoS-
17. System gauges replaced eve ry. 5 years or calibrated?
'Yes El
No'
Class I
18. Hydro -tested 150 psi or 50 psi greater than bead pressure for 2 hours (Dry
Yes Z
No 0
Standpipe Only)
19. All outlet valves and hose threads checked and have 2 1/2" Cap w/l/8" hole?
Yes
No El
20. Was 25 psi air test conducted?
Yes
No Z
21. Standpipes have 12" wrench clearance?
Yes Z
No El
Class 11
22. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours:
Yes
No El
23. Are all hoses, valves and controlling nozzles in good condition?
Yes E]
No El
24. Have flow tests been conducted at highest level for at least 30 seconds to make
Yes E]
No El
sure nozzle will work at pressure available (50 gpm at 35 psi minimum)?
25. Standpipe has 12" wrench clearance?
Yes El
No El
26. Have controlling valves been tested to verify that pressure regulating valves
Yes E]
No El
operate properly (not to exceed 100 psi Tip pressure)?
Class III
27. Hydro -tested at 150 psi or 50 psi greater than highest Operating pressure?
Yes El
No El
28. Was 25 psi air test conducted?
Yes El
No 0
29. All outlet valves and hose threads checked and have 21/2" Cap w/l/8" hole?
Yes 0
NoEl
30. Flow tests conducted to verify operating pressure of press Regulating valves (not
Yes
No El
to exceed 175-psi flowing)?
r A
0 -�
lb 1-77 T
Seattle Fire Department
Confidence Test Report
206-386-1448 Confidence Testing Officer
20&61-5-1068 (fax)
206-233-7219 Red Tag Hotline
STANDPIPE SYSTEM
(One System per Report)
Certification'Given-
RED F.
YELLO W
W HITE Z
CONFIDENCE TEST z REPAIRS
Occupancy Address: 23015 EDMONDS Occupancy Name: SEQUOYAH CONDOMINIUMS
WAY.EDMONDS
Building Owner: HOA Phone Number: SAME
Responsible Person: BRAD Phone Number: 4252752189
Building Owner Address: SAME
Date of Inspection: 10-19-9 Inspection Frequency/Type: Z 5 year
Testers Name
(Please Print): JIM FRY SFD Certification Number: scp-F248
Number of Bldg. Stories 4 Location of FD Connection: BY NORTH ENTRY
Primary Component: Standpipe System Make: NA
1 System Model: NA
- System Location:7 NORTH STAIRS Identification Number: BUILDING B
PROBLEMS FOUND: (If additional room is needed, please.add a separate sheet)
NONE
CORRECTIONS MADE: Date Corrected: Corrected By:
Of, additional room is needed, please add a separate sheet) SFD Certification Number: SCP -
NONE
This certifies that this fire and life safety system has been properly inspected for reliability to cover the
Items listed in this report and is consistent with Seattle Fire Department Fire Code standards, and that
discrepancies are noted and have been reported to the building- Owner/Manager for corrective'action.,
'Sidnaiure of Tester: Pho.ne # 2062415909
-resting Agency� A-1 FIRE EQUIPIVII$NT
Mailing Address: 1002 NORTH CENTRAL, KENT
Building Representative (signature)
Page I of 4
The items on the checklists below shall be inspected and tested. This list does not constitute all of the
required inspecting and testing of the fire and life safety system. Refer to the Seattle Fire
Department
Fire Code for inspecting and testing requirements.
General
1 . Is there 300 GPM flow at roof through each riser? N/A
Yes
El
No El
2. All fire department inl . e ' t * s and outlets equipped with approved plugs or caps (1/8
Yes
Z
N o
inch pressure relief hole in caps)?
3. Piping between. fire department connection and check valve is currently hydro-
Yes
El
No El
tested?
4. All control valves left in open position (except normally closed valves)?
Yes
Z
No El
5. Pumper connections are not obstructed?
Yes
Z
No El
6. Water flow switches operate properly? N/A Z
Yes
El
No E
7. Fire pump(s) start from roof flow? N/A El
Yes
E]
No M
8. Was the Fire Department Connection (FDC) back flushed?
Yes
Z
No F1
9. Are there hose cabinets in the building?
Yes
El
No Z
10. Is the building sprinklered?
Yes
El
No Z
11. Standpipe Classification
T2. Class I Standpipe?
Yes
Z
No E]
13. Class 11 Standpipe?
Yes
E]
No Z
14. Class III Standpipe?
Yes
El
No Z
15. Hose cabinet and/or sprinkler PRV testing form for each system? N/A El
Yes
El
No EI
16. Was debris found in the Fire Department Connection (FDC)?
Yes
El
No Z
17...S'ystem gauges replaced every 6ye6rs or, calibrated?
Yes
El
No El
Class I
18. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours (Dry
Yes
Z
No El
Standpipe Only)
19. All outlet valves and hose threads checked and have 2 1/2" Cap w/l/8" hole?
Yes
Z
No El
20. Was 25 psi air test conducted?
Yes
El
No E
21. Standpipes have 12" wrench clearance?
Yes
E
No El
Class 11
22. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours:
Yes
F�
�No El
23. Are,all hoses, valves and controlling nozzles in good condition?
Yes
El
No El
24. Have flow tests been conducted at highest level for at least 30 se - con - ds to make
Yes
El
No El
sure nozzle will work at pressure available (50 gpm at 35 psi minimum)?
25. Standpipe has 12" wrench clearance?
Yes
El
No El
26. Have controlling valves been tested to verify that pressure regulating valves
Yes'[]
No EI
operate properly (not to exceed 100 psi Tip pressure)?
Class 111.
27. Hydro -tested at 150 psi or 50 psi greater than highest Operating pressure?
Yes
No El
28. Was 25 psi air test conducted?
Yes
R
No.E1
29. All outlet valves and hose threads checked and have 2 1/2" Cap w/l/8" hole?
Yes
El
No 0
30. Flow tests conducted to verify operating pressure of press Regulating valves (not
Yes
El
No E
to exceed 175-psi flowing)?
-1
Page 2 of 4
-J,
Seattle Fire Department
Confidence Test Report
206-386-1448 Confidence Testing Officer
206-615-1068 (fax)
206-233-7219 Red Tag Hotline
STANDPIPE SYSTEM
(One System per Report)
Certification Given
RED
YELLOW
WHITE
CONFIDENCE TEST z REPAIRS 0
Occupancy Address: 23015 EDMONDS Occupancy Name: SEQUOYAH CONDOMINIUMS
WAY.EDMONDS
Building Owner: HOA Phone Number: SAME
Responsible Person: BRAD Phone Number: 4252752189
Building Owner Address: SAME
Date of Inspection: 10-19-9 Inspection Frequency/Type: Z 5 year
Testers Name
(Please Print): JIM FRY SFID Certification Number: scp-F248
Number of Bldg. Stories 4 Location of FID Connection: BY SOUTH ENTRY
Phriiary Component: Standpipe System Make: NA
System Model: NA
System -Location: SOUTH STAIRS Identification Number-. BUILDING B
PROBLEms FOUND: (If additional room is needed, please add a separate sheet)
NONE
CORRECTIONS MADE:- Date -,Corrected: Corrected By:
(If additional room is needed, please add a separate sheet) SFD Certification Number: SCP -
NONE
This certifies that this fire and life safety system has been properly inspected for reliability' to Cover the
Items listed in this report and is consistent with Seattle Fire Department Fire Code standards, and that
discrepancies are noted and have been. reported to the building OWnOr/Manager for,corrective action.
Signature of Tester: Phone # 206241 59 09
Testing Agency: A-1 FIRE EQUIPMENT
Mailing Address: 1002 NORTH CENTRAL, KENT
Building Representative (signature)
Page I of 4
The items on the checklists below shall be inspected and tested. This list does not constitute all of the
required inspecting and testing of the fire and life safety system. Refer to the Seattle Fire
Department
Fire Code for inspecting and testing requirements.
General..
1 . Is there.300 GPM flow.at roof through each riser? N/A Z
Yes
El
No El
2. All fire department inlets and outlets equipped with approved plugs or caps (1/8
Yes
Z
No E]
inch pressure relief hole in caps)?
3. Piping between fire department connection and check valve is currently hydro-
Yes
El
No El
tested?
4. All control valves left in open position (except normally closed valves)?
Yes
Z
No E-1
5. Pumper connections are not obstructed?
Yes
0
No El
6. Water flow switches operate properly? N/A
Yes
El
No D
7. Fire pump(s) start from roof flow? N/A El
Yes
E]
No Ej
8. Was the Fire Department Connection (FDC) back flushed?
Yes
Z
No El
9. Are there hose cabinets in the building?
Yes
0
No Z
10. Is the building sprinklered?
Yes
El
No Z
11. Standpipe Classification
12. Class I Standpipe?
Yes
Z
No El
13. Class 11 Standpipe?
Yes
El
No Z
14. Class III Standpipe?
Yes
El
No N
15. Hose cabinet and/or sprinkler PRV testing form for each system? N/A 0
Yes
El
No El
16. Was debris found in the Fire Department Connection (FDC)?
Yes
No Z
—17. System g.auges replaced'every 5�-y6ars or calibrated?
Yes
El
No El
Class I
18. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours (Dry
Yes
Z
No El
Standpipe Only)
19.AII outlet valves and hose threads checked and have 2 Y2" Cap w/l/8" hole?
Yes
Z
No El
20. Was 25 psi air test conducted?
Yes
0
No
21. Standpipes have 12" wrench clearance?
Yes
Z
No El
class 11
22. Hydro -tested 150 psi 0�66'I5�i greater than head pressure f . or 2 . hours:
Yes
El
No El
23. Are all hoses, valves and controlling nozzles in good condition?
Yes
El
No El
24. Have flow. tests been -conducted at highest level for at least 30secondstomake
Yes
El
No E)
sure nozzle will work at pressure available (50 gpm at 35 psi minimum)?
25. Standpipe has 12" wrench clearance?
Yes
D
No El
26. Have controlling valves been tested to verify that pressure regulating valves
Yes
El
No El
operate properly (not to exceed 100 psi Tip pressure)?
Class III
27. Hydro -tested at 150 psi or 50 psi greater than highest Operating. pressure?
Yes
El
No [j
28. Was 25 psi air test conducted?
Yes
El
No El
29. All outlet valves and hose threads checked and have 2 1/2" Cap w/l/8" hole?'
Yes
El
No El
30. Flow tests conducted to verify operating pressure of press Regulating valves (not
Yes
El
No 0
to exceed 175-psi flowing)?
Page 2 of 4
0-�
t�Dl -� ,
Seattle Fire Department
Confidence Test Report
206-386-1448 Confidence Testing Officer
206-615-1068 (fax)
206-233-7219 Red Tag Hotline
-STAN-DPIPE'SYSTE'M'
(One System per Report)
Certification Given -
RED 1:1
YELLOW El
CONFIDENCE TEST z REPAIRS 0
Occupancy Address- 23015 EDMONDS Occupancy Name: SEQUOYAH CONDOMINIUMS
WAY.EDMONDS
Building Owner: HOA Phone Number: SAME
Responsible Person: BRAD Phone Number: 4252752189
Building Owner Address: SAME
Date of Inspection: 10-19-9 Inspection Frequency/Type: Z 5 year
Testers Name
(Please Print): JIM FRY SFD Certification Number: SCP-F248
Number of Bldg. Stories 4 Location of FID Connection: BY NORTH ENTRY
Primbi ry Component: Standpipe System Make: NA
System Model: NA
System Location: NORTH STAIRS Identification Number:: BUILDING C
--PROBLEMS FOUND: (If additional room is needed, please add a separate sheet)
NONE
CORRECTIONS MADE: Date Corrected: Corrected By:
(If additional room is needed, please add a separate sheet) SFD Certification Number: SCP -
NONE
This certifies that this fire and life safety system has been properly inspected for reliability to cover the
Items listed in this report and is consistent with Seattle Fire Department Fire Code standards, and that
discrepancies are noted and have been reported to the building Owner/Manager for Corrective action.,'
.Signature of Tester: Phone # .206 241 5909
Testing Agency: A-1 FIRE EQUIP ENT
Mailing Address: 1002 NORTH CENTRAL, KENT
Building Representative (signature)
Page I of 4
The items on the checklists below shall be inspected and tested. This list does not constitute all of the
required inspecting and testing of the fire and life safety system. Refer to the Seattle Fire
Department
Fire Code for inspecting and testing requirements.
General.
1 . Is there 300 GPM flow at roof through each riser? N/A Z
Yes
El
No E-]
2. All fire department inlet's and outlets equipped with approved plugs or caps (1/8
Yes
Z
No El
inch pressure relief hole in taps)?
3. Piping between fire department connection and check valve is currently hydro-
Yes
EI
No El
tested?
4. All control valves left in open position (except normally closed valves)?
Yes
Z
No El
5. Pumper connections are not obstructed?
Yes
Z
No El
6. Water flow switches operate properly? N/A Z
Yes
El
No El
7. Fire pump(s) start from roof flow? N/A 11
Yes
El
No El
8. Was the Fire Department Connection (FDC) back flushed?
Yes
Z
No D
9. Are there hose cabinets in the building?
Yes
El
No 0
10. Is the building sprinklered?
Yes
El
No Z
11. Standpipe Classification
12. Class I Standpipe?
Yes
Z
No El
13. Class 11 Standpipe?
Yes
M
No Z
14. Class III Standpipe?
Yes
El
No E
15. Hose cabinet and/or sprinkler PRV testing form for each system? N/A 0
Yes
EI
No El
16. Was debris found in the Fire Department Connection (FDC)?
Yes
EI
No Z
17. Systern gauges replaced every 5 years! or calibrated? J
Yes
0
No El
Class I
18. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours (Dry
Yes
Z
No El
Standpipe Only)
19. All outlet valves and hose threads checked and have 2 Y2" Cap w/l/8" hole?
Yes
Z
No El
20. Was 25 psi air test conducted?
Yes
EI
No Z
21. Standpipes have 12" wrench clearance?
Yes
E
No El
Class 11
22. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours:
Yes
M-
No EJ
23. Are.a.11 hoses, valves and controlling nozzles in good condition?
Yes
El
No El
24. Have flow tests been conducted at highest level for at least 30 seconds to make
Yes
El
No EI
sure nozzle will work at pressure available (50 gpm at 35 psi minimum)?
25. Standpipe has 12" wrench clearance?
Yes
El
No El
26. Have controlling valves been tested to verify that pressure regulating valves
Yes
El
No E-1
operate properly (not to exceed 100 psi Tip pressure)?
Class III
27. Hydro -tested at 150 psi or 50 psi greater than highest Operating pressure?
Yes
El
No El
28. Was 25 psi air test conducted?
Yes
El
*No El
29. All outlet valves and hose threads checked and have 2 1/2" Cap w/118" hole?
Yes
El
No El
30. Flow tests conducted to verify operating pressure of press Regulating valves (not
Yes
El
No El
to exceed 175-psi flowing)?
Pap 2 of 4
.... ......
0
Seattle Fire Department
Confidence Test Report
206-386-1448 Confidence Testing Officer
206-615-1068 (fax)
206-233-7219 Red Tag Hotline
STANDPIPE SYSTEM
Certific-a-fion Given
(One Sy�temper',Rbport)
RED
YELLOW
"WHITE
CONFIDENCE TEST I Z-1 REPAIRS E]
Occupancy Address: 23015 EDMONDS Occupancy Name: SEQUOYAH CONDOMINIUMS
WAY.EDMONDS
Building Owner: HOA Phone Number: SAME
Responsible Person: BRAD Phone Number: 4252752189
Building Owner Address: SAME
Date of Inspection: 10-19-9 Inspection Frequency/Type: Z 5 year
Testers Name
(Please Print): JIM FRY SFD Certification Number: scp-F248
.Number of Bldg. Stories 4 Location of FD Connection: BY SOUTH ENTRY
'Primary Component: Standpipe System Make: 'NA
-System Model: NA
System Locatipn;. SOUTH STAIRS Identification Number: *.'B-UIL-DING C
PROBLEMS FOUND: (If additional room.is needed, please add a separate sheet)
NONE
CORRECTIONS MADE: Date Corrected: Corrected By:
-(If additional room is needed, please add a separate sheet) SFD Certification Number: SCP -
NONE
'This� certifies -that this fire and life safety system 'has been properly inspected for reliability to cover the
Items listed in this report and is consistent with Seattle Fire Department Fire Code standards, and that
discrepancies- are- noted and have- been- reported to -the -building Owner/Manager for -corrective action.
Signature of Tester: Phone # 206241 5909
Testing Agency: A-1 FIRE'EQUIPMERT
Mailing Address: 1002 NORTH CENTRAL, KENT
Building Representative (signature)
Page I of 4
The items on the checklists below shall be inspected and tested. This list does not constitute all of the
required inspecting and testing of the fire and life safety system. Refer to the Seattle Fire
Department
Fire Code for inspecting and testing requirements.
General
1 . Is there 300 GPM flow at roof through each riser? N/A
Yes-
El
No El
2. All fire department inlets and outlets equipped with approved plugs or caps (1/8
Yes
0
No
inch pressure relief hole in caps)?
3. Piping between fire department connection and check valve is currently hydro-
Yes
El
No 0
tested?
4. All control valves left in open position (except normally closed valves)?
Yes
0
No El
5. Pumper connections are not obstructed?
Yes
0
No 0
6. Water flow switches operate properly? N/A
Yes
E]
No El
7. Fire pump(s) start from roof flow? N/A El
Yes
[:]
-No El
8. Was the Fire Department Connection (FDC) back flushed?
Yes
Z
No [I
9. Are there hose cabinets in the building?
Yes
El
No Z
10. Is the building sprinklered?
Yes
El
No Z
11. Standpipe Classification
12. Class I Standpipe?
Yes
Z
No El
13. Class 11 Standpipe?
Yes
El
No [E
14. Class III Standpipe?
Yes
Ej
No Z
15. Hose cabinet and/or sprinkler PRV testing form for each system? N/A 0
Yes
E]
No [I
16. Was debris found in the Fire Department Connection (FDC)?
Yes
El
No 0
17.-.System gauges replaced every 5 years or calibrated?.
Yes,
El
No El
Class 1
18. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours (Dry
Yes
Z
No El
Standpipe Only)
19. All outlet valves and hose threads checked and have 2 1/2" Cap w/1/8" hole?
Yes
Z
No El
20. Was 25 psi air test conducted?
Yes
El
No Z
21. Standpipes have 12" wrench clearance?
Yes
Z
No El
Class 11
22. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours:
Yes' 0
"No El
23. Are all hoses, valves and controlling nozzles in good condition?
Yes
El
No 0
24. Have flow tests been conducted at highest level for at least 30 seconds to make
Yes
E-1
No F�
sure nozzle will work at pressure available (50 gpm at 35 psi minimum)?
25.-Standpipe has 12" wrench clearance?
Yes
El
No El
26. Have controlling valves been tested to verify that pressure regulati I ng valves
Yes
El
No El
operate properly (not to exceed 100 psi Tip pressure)?
Class III
27. Hydro -tested at 150 psi or 50 psi greater than highest Operating pressure?
Yes
El
No El
28. Was 25'psi air test conducted?
Yes
El
No El
29. All outlet valves and hose threads checked and have 2 1/2" Cap *W/1/8" hole?
Yes
[]
No 0
30. Flow tests conducted to verify operating pressure of press Regulating valves (not
Yes
El
No El
to exceed 175-psi flowing)?
Page 2 of 4
'Seattle Fire Department
Confidence Test Report
206-386-1448 Confidence Testing Officer
206-615-1068 (fax)
206-233-7219 Red Tag Hotline
STAN DPIPESYSTEM'
(One System per Report)
Ci�rtification` Given
RED
YELLOW
WHITE
CONFIDENCE TEST T 07 REPAIRS7-11
Occupancy Address: 23015 EDMONDS Occupancy Name: SEQUOYAH CONDOM I INIUMS
WAY.EDMONDS
Building Owner: HOA Phone Number: SAME
Responsible Person: BRAD Phone Number: 425 275.2189
Building Owner Address: SAME
Date of Inspection: 10-19-9 Inspection Frequency/Type: Z 5 year
Testers Name
(Please Print): JIM FRY SFID Certification Number: scp-F248
Number of Bldg. Stories 4 Location of FID Connection: BY SOUTH ENTRY
Primary Component: Standp ipe System Make: NA
Syst e m Mode 1: NA
System Location: SOUTH STAIRS - Identification Number: BUILDING D
PROBLEIVIs FOUND: (If additional room is* needed, please add a separate sheet)
NONE
CORRECTIONS MADE: Date Corrected: Corrected By:
(If additional room is needed, please add a separate sheet) SFD Certification Number: SCP -
NONE
This certifies that this fire and life safety system has been properly inspected for reliability to cover the'
Items listed in this repprt.and is consistent with Seattle Fire Department Fire Code standards, and that
discrepancies are noted and have been reported to the building Owner/Manager.for corrective action.,
Signature of Tester: Phone # 206 241 5909-
Testing Agency: A-1 FIRE EQUIPIVIBNT
Mailing Address: 1002 NORTH CENTRAL, KENT
Building Representative (signature)
Page I of 4
11P OF
The items on the checklists below shall be inspected and tested. This list does not constitute all of the
required inspecting and'testing of the fire and, life safety system. Refer to the Seattle Fire
Department
Fire Code for inspecting and testing requirements.
Ge'ne- ral
1 . Is there 300 GPM flow at roof through each riser? N/A
Yes
No E]
2. All.fire department inlets and outlets equipped with approved plugs or caps (1/8
Yes
Z
No El
inch pressure relief hole in caps)?
3. Piping between fire department connection and check valve is currently hydro-
Yes
El
No El
tested?
4. All control valves left in open position (except normally closed valves)?
Yes
Z
No El
5. Pumper connections are not obstructed?
Yes
Z
No El
6. Water flow switches operate properly? N/A Z
Yes
El
No El
7. Fire pump(s) start from roof flow? N/A 0
Yes
[I
No El
8. Was the Fire Department Connection (FDC) back flushed?
Yes,
Z
No 0
9. Are there hose cabinets in the building?
Yes
El
No Z
10. Is the building sprinklered?
Yes
El
No Z
"11. Standpipe Classification
12. Class I Standpipe?
Yes
Z
No El
13. Class 11 Standpipe?
Yes
[I
No Z
14. Class III Standpipe?
Yes
El
No 0
15. Hose cabinet and/or sprinkler PRV testing form for each system? N/A 0
Yes
E]
No El
16. Was debris found in the Fire Department Connection (FDC)?
Yes
El
No Z
17.System:.g'auges'repladed.eVe'ry..�:5y' rs;orc librate ?
a
'Yes,
El
No El
Class I
18. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours (Dry
Yes
Z
No El
Standpipe Only)
19. All outlet valves and hose threads checked and have 2 Y2" Cap w/11/8" hole?
Yes
Z
No Ej
20. Was 25 psi air test conducted?
Yes
El
No Z
21. Stan dpipes have 12" wrench clearance?
Yes
Z
No El
Class 11
22. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours:
Yes
El
No El
23. Are all hoses, valves and controlling nozzles in good condition?
Yes
El
No El
24. Have flow tests been conducted at highest level for at least 30 seconds to make
Yes
El
No El
sure nozzle will work at pressure available (50 gpm at 35 psi minimunn)?
25. Standpipe has 12" wrench clearance?
Yes
El
No El
26. Have controlling valves been tested to verify that pressure regulating valves
Yes
El
No El
operate properly (not to exceed 100 psi Tip pressure)?
Class III
27. Hydro -tested at 150 psi or 50 psi greater than highest Operating pressure?
Yes
0
No.E]
28. Was 25 psi air test conducted?
Yes
[I
No 0
29. All outlet valves and hose threads checked and have 2 Y2" Cap w/11/8" hole?
Yes
[I
No 0
30. Flow tests conducted to verify operating pressure of press Regulating valves (not
Yes
[I
No El
to exceed 175-psi flowing)?
Page 2 of 4
Seattle Fire Department
Confidence Test Report
206-386-1448 Confidence Testing Officer
206-615-1068 (fax) . -
206-233-7219 Red Tag Hotline
STANPPIPESYSTEM -
(One System per Report)
Certification�,-Given
RED
YELLOW - E:1
I WHITE Z
CONFIDENCE TEST z -REPAIRS 1:1
Occupancy Address: 23015 EDMONDS Occupancy Name: SEQUOYAH CONDOMINIUMS
WAY.EDMONDS
Building Owner: HOA Phone Number: SAME
Responsible Person: BRAD Phone Number: 4252752189
Building Owner Address: SAME
Date of Inspection: 10-19-9 Inspection Frequency[Type: Z 5 year
.Testers Name
(Please Print): JIM FRY SFD Certification Number: SCP-F248
Number of Bldg. Stories 4 Location of FD Connection: BY NORTH ENTRY
Primary Component: Standpipe System Make: NA
..Systern Model: NA
System Location: NORTH STAIRS Identification Number: BUILDING D
PROBLEMS FOUND: (If additional room is needed, please add a separate sheet)
NONE
CORRECTIONS MADE: Date Corrected: Corrected By:
(if additional room is needed, please add a separate sheet) SFID Certification Number: SCP -
NONE
This certifies- that this fire and life safety system has been properly inspected for reliability to cover the
Items listed in this report and is consistent with Seattle Fire Department Fire Code standards, and that
discrepancies are noted and have been reported to the building Owner/Manager for corrective action.
-Signature of Tester: Phone # 206241 5909
Testing Agency: A-1 FIRE EQUIPMENT
Mailing Address: 1002 NORTH CENTRAL, KENT
Building Representative (signature)
Page I of 4
The items on the checklists below shall be inspected and tested. This list does not constitute all of the
required inspecting and testing of the fire and life safety system. Refer to the Seattle Fire Department
Fire Code for inspecting and testing requirements.
General
1 . Is there 300 GPM flow at roof through each riser? N/A
Yes
E]
No E]
2. All fire department inlets and outlets equipped with approved plugs or caps (1/8
Yes
No
inch pressure relief hole in caps)?
3. Piping between fire department connection and check valve is currently hydro-
Yes
EI
No El
tested?
4. All control valves left in open position (except normally closed valves)?
Yes
E
No [I
5. Pumper connections are not obstructed?
Yes
E
No El
6. Water flow switches operate properly? N/A
Yes
[I
No El
7. Fire pump(s) start from roof flow? N/A 11
Yes
El
No E]
8. Was the Fire Department Connection (FDC) back flushed?
Yes
E
No Ej
9. Are there hose cabinets in the building?
Yes
[]
No Z
10. Is the building sprinklered?
Yes
El
No Z
11. Standpipe Classification
12. Class I Standpipe?
Yes
Z
No
13. Class 11 Standpipe?
Yes
E]
No E
14. Class III Standpipe?
Yes
E]
No 0
15. Hose cabinet and/or sprinkler PRV testing form for each system? N/A
Yes
El
No EJ
16. Was debris found in the Fire Department Connection (FDC)?
Yes
0
No E
17. System gauges replaced every, 5 years or calibrated?
Yes
El
No El
Class 1
18. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours (Dry
Yes
E
No El
Standpipe Only)
19. All outlet valves and hose threads checked and have 2 Y2" Cap w/l/8" hole?
Yes
Z
No El
20. Was 25 psi air test conducted?
Yes
El
No N
21. Standpipes have 12" wrench clearance?
Yes
0
No El
Class 11
22. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours:
Yes
0
No El
23. Are all hoses, valves and controlling nozzles in good condition?
Yes
D
No El
24. Have flow tests been conducted at highest level for at least 30 seconds to make
Yes
El
No [I
sure nozzle will work at pressure available (50 gpm at 35 psi minimum)?
25. Standpipe has 12" wrench clearance?
Yes
0
No [I
26. Have controlling valves been tested to verify that pressure regulating valves
Yes
El
No El
operate properly (not to exceed 100 psi Tip pressure)?
Class II11'
27. Hydro -tested at 150 psi or 50 psi greater than highest Operating pressure?
Yes
EI
No El
28. Was 25 psi air test conducted?
Yes
El
No El
29. All outlet valves and hose threads checked and have 2 1/2" Cap w/l/8" hole?
Yes
0
No El
30. Flow tests conducted to verify operating pressure of press Regulating valves (not
Yes
El
No El
to exceed 175-psi flowing)?
Page 2 of 4
Seattle Fire Department
Confidence Test Report
- 206-386-1448 Confidence Testing Officer
206�615-11068 (fax)
206-233-7219 Red Tag Hotline
STANDPIPE SYS'T-E"M
(One System per Report)
Certification Given
RED E:1
I YELLOW 0
1 WHITE Z
___T7CONFIDENCE TEST REPAIRS70_
Occupancy Address: 23015 EDMONDS Occupancy Name: SEQUOYAH CONDOMINIUMS
WAY.EDMONDS
Building Owner: HOA Phone Number: SAME
Responsible Person: BRAD Phone Number: 4252752189
Building Owner Address: SAME
Date of Inspection: 10-19-9 Inspection Frequency/Type: 5 year
Testers Name
(Please Print): JIM FRY SFD Certification Number: scp-F248
Number of Bldg. Stories 4 Location of FD Connection: BY SOUTH ENTRY
Primary Component: Standpipe System Make: NA
§ystem Model: NA
System Location: SOUTH STAIRS ldentificdtior� Numb&r:, BUI[LDINd E
PROBLEms FOUND: (if additional room is needed, please add a separate -sheet)
NONE
CORRECTIONS MADE: Date Corrected: Corrected By:
(If additional room is needed, please add a separate sheet) SFD Certification Number: SCP -
NONE
This certifies that this fire and life safety system -has been properly inspected'for reliability to cover the-.
-Iterns listed in this report and is consistent with Seattle Fire Department Fire Code standards, and' that
discrepancies are noted and have been reported to the building Owner/Manager for corrective action.
Signature of Tester: Phone # 206241 5909
Testing Agency: A-1 FIRE EQUIPMAT
Mailing Address: 1002 NORTH CENTRAL, KENT
1 Building Representative (signature)
Page I of 4
The items on the checklists below shall be inspected and tested. This list does not constitute all of the
required inspecting and testing of the fire and life safety system. Refer to the Seattle Fire
Department
Fire Code for inspecting and testing requirements.
General
1 . Is there 300 GPM flow �at, roof through each riser? N/A
Yes
No
2. All fire depaftment inlets and -outlets * equipped with approved plugs or caps (1/8
Yes
2
No E-1
inch pressure relief hole in caps)?
3. Piping between fire department connection and check valve is currently hydro-
Yes
El
No D
tested?
4. All control valves left in open position (except normally closed valves)?
Yes
E
No 0
5. Pumper connections are not obstructed?
Yes
Z
No D
6. Water flow switches operate properly? N/A
Yes
[:1
No FI
7. Fire pump(s) start from roof flow? N/A EI
Yes
0
No El
8. Was the Fire Department Connection (FDC) back flushed?
Yes
E
No 0
9. Are there hose cabinets in the building?
Yes
El
No E
10. Is the building sprinklered?
Yes
El
No E
11. Standpipe Classification
12. Class I Standpipe?
Yes
E
No El
13. Class 11 Standpipe?
Yes
El
No Z
14. Class III Standpipe?
Yes
El
NO Z
15. Hose cabinet and/or sprinkler PRV testing form for each system? N/A 0
Yes
0*
No El
16. Was debris found in the Fire Department Connection (FDC)?
Yes
El
No 0
17. System gauges replaced',every &.years or calibrated?
Yes.
El
No El
Class 1
18. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours (Dry
Yes
E
No M
Standpipe Only)
19. All outlet valves and hose threads checked and have 2 1/2" Cap w/l/8" hole?
Yes
E
No
20. Was 25 psi air test conducted?
Yes
El
No
21. Standpipes have 12" wrench clearance?
Yes
E
No El
Class 11
22. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours:
Yes
El
No El
23. Are all hoses, valves and controlling nozzles in good condition?
Yes
Ej
No El
24. Have flow tests been conducted at highest level for at least 30 seconds to make
Yes
El
No El
sure nozzle will work at pressure available (50 gpm at 35 psi minimum)?
25. Standpipe has 12" wrench clearance?
Yes
El
No El
26. Have controlling valves been tested to verify that pressure regulating valves
Yes
El
No El
operate properly (not to exceed 100 psi Tip pressure)?
Class III
27. Hydro -tested at 150 psi or 50 psi greater than highest Operating pressure?
Yes
El
No El
28. Was 25 psi air test conducted?
Yes
E-1
No Ej
29. All outlet valves and hose threads checked and have 2 1/2" Cap w/l/8" hole?
Yes
El
No El
30. Flow tests conducted to verify operating pressure of press Regulating valves (not
Yes
El
No El
to exceed 175-psi flowing)?
Page 2 of 4
vtsj'--�
Seattle Fire Department
Confidence Test Report
206-386-1448 Confidence Testing Officer
206-615-1068 (fax)
206-233-7219 Red Tag Hotline
STAN DPIPE -SYSTEM,
(One System per Report)
Ce'rtification,Given
RED
YELLOW
WHITE
CONFIDENCE TEST z REPAIRS El
Occupancy Address: 23015 EDMONDS Occupancy Name: SEQUOYAH CONDOMINIUMS
WAY.EDMONDS
Building Owner: HOA Phone Number: SAME
Responsible Person: BRAD Phone Number: 4252752189
Building Owner Address: SAME
Date of Inspection: 10-19-9 Inspection Frequency/Type: Z 5 year
Testers Name
(Please Print): JIM FRY SFD Certification Number: SCP-F248
Number of Bldg. Stories 4 Location of FD Connection: BY NORTH ENTRY
Primary Component: Standpipe System Make: NA
System Model: NA
System Location: NORTH STAIRS Identification Number: BUILDING E
PROBLEMS FOUND: (If additional room is needed, please add a separate sheet)
NONE
CORRECTIONS MADE: Date Corrected: Corrected By:
(If additional room is needed, please add a separate sheet) SFD Certification Number: SCP -
NONE
This certifies that this fire and life safety system has been properly inspected for reliability to cover the
Items listed in this report and is consistent with Seattle Fire Department Fire Code standards, and that
disc - repancies ar I e noted and h I ay.e been reported to the building Owner/Manager for corrective action.
Signature of Tester: Phone # 206241 5909
testing Agency: A-1 FIRE EQUIPIVINT
Mailing Address: 1002 NORTH CENTRAL, KENT
Building Representative (signature)
Page I of 4
The items on the checklists below shall be inspected and tested. This list does not constitute all of the
required inspecting and testing of the fire and life safety system. Refer to the Seattle Fire Department
Fire Code for inspecting and testing requirements.
General
1 . Is there 300 GPM flow at roof through each riser? N/A
Yes
F�
No
2. All fire department inlets and -outlets equipped with approved plugs or caps (1 /8
Yes
0
No
inch pressure relief hole in caps)?
3. Piping between fire department connection and check valve is currently hydro -
Yes
0
N o El
tested?
4. All control valves left in open position (except normally closed valves)?
Yes
2
No F-1
5. Pumper connections are not obstructed?
Yes
Z
No
6. Water flow switches operate properly? N/A Z
Yes
F�
IN o
7. Fire pump(s) start from roof flow? N/A 0
Yes
El
No El
8. Was the Fire Department Connection (FDC) back flushed?
Yes
Z
No El
9. Are there hose cabinets in the building?
Yes
El
No Z
10. Is the building sprinklered?
Yes
El
No Z
11. Standpipe Classification
12. Class I Standpipe?
Yes
Z
No El
13. Class 11 Standpipe?
Yes
El
No Z
14. Class III Standpipe?
Yes
E]
No Z
15. Hose cabinet and/or sprinkler PRV testing form for each system? N/A El
Yes
0
No El
16. Was debris found in the Fire Department Connection (FDC)?
Yes
El
No 0
17. System; gauges replaced every 5 years or calibrated?
Yes
El
No El
Class I
18. Hydro -tested 150 psi or 50 psi greater than.head pressure for 2 hours (Dry
Yes
0
No El
Standpipe Only)
19. All outlet valves and hose threads checked and have 2 Y2" Cap w/l/8" hole?
Yes
0
No El
20. Was 25 psi air test conducted?
Yes
E]
No Z
21. Standpipes have 12" wrench clearance?
Yes
Z
No El
Class 11
22. Hydro -tested 150 psi or 50 psi greater than head pressure for 2 hours:
Yes
El
No 0
23. Are all hoses, valves and controlling nozzles in good condition?
Yes
El
No El
24. Have flow tests been conducted at highest level for at least 30 seconds to make
Yes
El
No El
sure nozzle will work at pressure available (50 gpm at 35 psi minimum)?
25. -Standpipe has 12" wrench clearance?
Yes
E]
No El
26. Have controlling valves been tested to verify that pressure regulating valves
Yes
E]
No El
operate properly (not to exceed 100 psi Tip pressure)?
Class I'll.
27. Hydro -tested at 150 psi or 50 psi greater than highest Operating pressure?
Yes
E1
No El
28. Was 25 psi air test conducted?
Yes
El
No F-1
29. All outlet valves and hose threads checked and have 2 1/2" Cap w/l/8" hole?
Yes
D
No El
30. Flow tests conducted to verify operating pressure of press Regulating valves (not
Yes
El
No El
to exceed 175-psi flowing)?
Page 2 of 4
WASHINGTON ALARM, INC.
1253 South Jackson Street
Seattle, WA 98144
Ph. (206) 328-1800 FAX (206) 328-6755
FOR THE CITY OF &A4h(Od<
Electrical Contractor's License No. WASHIAI282C3
SFD Examination Certificate No. UL Certificate No
FIRE ALARM SYSTEM CONFIDENCE TEST REPORT
CENTRAL STATION TRANSMITTER TEST REPORT
Central Station Account No.
Occupied as (major tenant)
Address - �_.; 0, 1 S—
n dos. btd
Zip Cd. '760;& Phone No.
Fire Department representative present ".41,1
No. of initiating circui No. of signaling circuits
Type of test Monthly Quarterly C3 Semi-Arinupi �S—Annual Accept
5� �e.,ftj I
Fire control panel manufacturer I Z, ffil c,'Vvk Model No. SS -7, 0
Central Station transmitter manufacturer Model No.
-7
Battery voltage volts Battery charger voltage -2— volts
Battery voltage under alarm load (with horns/bells sounding) — 7— q- Z- — volts
Transmitter tripped by which initiating circuit -5mOA-e!;
CENTRAL STATION
ji 1,4 FIRE CONTROL PANEL TRANSMITTER
Smoke detectors cleaned?
System operates on AC power
1;6 Yes
1:1
No
C]
NA
1:40 Yes
0
No
"Alarm Silence" results in tbl. sig.
Yes
0
No
NA
Ll
Yes
A
No
Loss of AC results in trouble signal
Yes
No
NA
Yes
No
System operates on battery
Yes
No
NA
Yes
No
All circuits checked for elec. supv.
Yes
No
NA
Yes
No
Test meets manufacturer's specs.
Yes
No
NA
Yes
No
All auxiliary equipment operates
Yes
No
NA
Key to fire control panel available
t90%
I+jr Yes
No
NA
Operating instructions posted
Yes
No
NA
Test record posted at control panel
Yes
No
NA
Yes
C3
No
Automatic time delay o general alarm
—
minutes
I
zy
Time initiated — tO
Time received by Central
Station
EQUIPMENT TESTED
4T) TY E OF EQUIPM ENT
NO. OF UNITS
TESTED
SATISFACTORY
YES NO NA
NO. OF UNITS
IN BUILDING
Bells,A-R�4 Chimes, Voice Alarms, Speakers, Water Gongs
3-7
1>0
:57
Visual Alarm Devices
X,
Trouble Indicators
Heat Detectors
Ile
Smoke Detectors
Smoke Beams
Sprinkler Waterflow Alarms
Sprinkler Supervisory Switches
Manual Pull Stations
Ventilation Controls Operate
Annunciators
Elevator Recall
Fire Dampers/Smoke Dampers
Phone jacks
;Vdiomatic Door - Release
Other
THIS IS TO CERTIFY THAT THIS FIRE ALARM SYSTEM/CENTRAL STATION TRANSMITTER HAS BEEN PROPERLY TESTED AND INSPECTED FOR
RELIABILITY TO COVER THE ITEMS LISTED IN THIS REPORT, IS CONSISTENT WITH FIRE ALARM MAINTENANCE STANDARDS/MANUFACTURER'S
REQUIREMENTS, AND ALL CORRECTIONS HAVE/HAVE NOT BEEN MADE.
Signature of Inspector Date .2 0
Signature of Owner s aepresentative
Problems Found
Corrections Made
Date Corrected By
WASHINGTON ALARM, INC.
J253 South Jackson Street
Seattle, WA 98144
Ph. (206) 328-1800 - FAX (206) 328-6755
FORTHECITYOF LOMDNDS
Electrical Contractor's License No. WASHIA1282C3
SFD Examination Certificate No.
UL Certificate No
FIRE ALARM SYSTEM CONFIDENCE TEST REPORT
CENTRAL STATION TRANSMITTER TEST REPORT
Central Station Account No. 4 OQ06-7 q
Occupied as (major tenant) St Q.;JC2 VA14 C-OW061 BID[$
Address - 2.2-0110 10fh ANce- i-) Zip Cd. (,Q Phone No. IJ 16
Fire Department representative present A
No. of initiating circuits -5 No. of signaling circuits
Type of test 0 Monthly 0 Quarterly Semi -Annual Annual Accept
Fire control panel manufacturer < nk V, wak Model No. S 1%210
e o
Central Station transmitter manufacturer Model No.
Battery voltage -2 volts Battery charger voltage 2- -7. volts
Battery voltage under alarm load (with homs/bells sounding) volts
Transmitter tripped by which initiating circuit Sma"_Ni Fulfs,
Smoke detectors cleaned? I&
System operates on AC power
"Alarm Silence" results in tbl. sig.
Loss of AC results in trouble signal
System operates on battery
All circuits checked for elec. supv.
Test meets manufacturer's specs.
All auxiliary equipment operates
Key to fire control panel available
Operating instructions posted
Test record posted at control panel
Automatic time delay of general alarm
Time initiated — / �!) -, 0,5-
CENTRAL STATION
FIRE CONTROL PANEL TRANSMITTER
Yes C3 No C] NA 0 Yes C3 No
Yes 0 No 1!�P NA C3 Yes 9 No
Yes
No
0
NA
V Yes
No
Yes
No
0
NA
Yes
No
Yes
No
1:1
NA
1_�" Yes
No
Yes
0
No
1:k
N A
ri%en .
1-fr- Y es
ID
No
Ck
Yes
ID
No
NA
UP
Yes
No
NA
Yes
No
NA
Yes
No
NA
Yes
No
minutes
Time received by Central Station 13: ep -s—
EQUIPMENT TESTED
46:) TYPE OF EQUIPMENT
NO. OF UNITS
TESTED
SATISFACTORY
YES NO NA
NO. OF UNITS
IN BUILDING
Bells, 114-6VI Chimes, Voice Alarms, Speakers, Water Gongs
77
Z7
Visual Alarm Devices
Trouble Indicators
Heat Detectors
Smoke Detectors
3,1
Smoke Beams
Sprinkler Waterflow Alarms
Sprinkler Supervisory Switches
Manual Pull Stations
Ventilation Controls Operate
Annunciators
Elevator Recall
Fire Dampers/Smoke Dampers
Phone Jacks
Automatic Door Release
Or -
Other
THIS IS TO CERTIFY THAT THIS FIRE ALARM SYSTEWCENTRAL STATION TRANSMITTER HAS BEEN PROPERLY TESTED AND INSPECTED FOR
RELIABILITY TO COVER THE ITEMS LISTED IN THIS REPORT, IS CONSISTENT WITH FIRE ALARM MAINTENANCE STANDARDS/MAI-JUFACTURER'S
REQUIREMENTS, AND ALL CORRECTIO14S HAVE/HAVE NOT BEEN MADE.
Signature of Inspec r 'e�� �ZN .4ZE Date 6gZ
Signature of Owne C's R rresentative
Problems Found
Corrections Made
Date Corrected By
WASHINGTON ALARM, INC. FORTHECITYOF
7253 South Jackson Street
Seattle, WA 98144
Ph. (206) 328-1800 FAX (206) 328-6755
Electrical Contractor's License No. WASHIA1282C3
SFD Examination Certificate No. UL Certificate No.
�Cr FIRE ALARM SYSTEM CONFIDENCE TEST REPORT
S CENTRAL STATION TRANSMITTER TEST REPORT
Central Station Account No.
Occupied as (major tenant) 5eqVID4'r, %n C-bo 49 0 S, Bid C-
Address — 2.1—A 10 !qo tm ket 1A I —Zip Cd. %b7_&9 Phone No. yJ /a
Fire Department representative present
No. of initiating circuits No. of signaling circuits 7)
Type of test C) Monthly Quarterly Semi -Annual Of Annual ID Accept
Fire control panel manufacturer �P_ r.-A Model No. SIB
'% %
Central Station transmitter manufacturer Model No.
Battery voltage 2-5 - I> -volts Battery charger voltage -27- 3 —volts
Battery voltage under alarm load (with horns/bells sounding) 2_q -& . volts
Transmitter tripped by which initiating circuit srno V=4 5, 11 t4eq+r.
Smoke detectors cleaned? AJ 1A
System operates on AC power
"Alarm Silence" results in tbl. sig.
Loss of AC results in trouble signal
System operates on battery
All circuits checked for elec. supv.
Test meets manufacturer's specs.
CENTRAL STATION
FIRE CONTROL PANEL
TRANSMITTER
Yes
ID
No
NA
Yes
No
Yes
No
NA
Yes
No
Yes
No
NA
Yes
No
Yes
No
NA
Yes
No
Yes
No
NA
Yes
No
Yes
No
NA
Yes
No
All auxiliary equipment operates
Yes
No
NA
Key to fire control panel available
Yes
No
NA
Operating instructions posted
Yes
No
NA
Test record posted at control panel
Yes
No
NA Yes
Automatic time delay of general alarm
minutes
91 : 10
Time initiated L —
Time received by Central Station
62
�D
EQUIPMENT TESTED
0 No
TYPE OF EQUIPMENT
NO. OF UNITS
TESTED
SATISFACTORY
YES NO NA
NO. OF UNITS
IN BUILDING
Bells, P�P;, Chimes, Voice Alarms, Speakers, Water Gongs
7-7
z- 7
Visu�l Alarm Devices
Trouble Indicators
Heat Detectors
2—
Smoke Detectors
2- P5
2!
Smoke Beams
Sprinkler Waterflow Alarms
Sprinkler Supervisory Switches
Manual Pull Stations
Ventilation Controls Operate
Annunciators
Elevator Recall
Fire Dampers/Smoke Dampers
Phone jacks
Automatic 13 or Release
Other
THIS IS TO CERTIFY THAT THIS FIRE ALARM SYSTEM/CENTRAL STATION TRANSMITTER HAS BEEN PROPERLY TESTED AND INSPECTED FOR
RELIABILITY TO COVER THE ITEMS LISTED IN THIS REPORT, IS CONSISTENT WITH FIRE ALARM MAINTENANCE STANDARDS/MANUFACTURER'S
REQUIREMENTS, AND ALL CORRECTIOIS HAVE/HAVE NOT B . EEN MADE.
Signature of Inspec 2ets4min ?'? Date i011o
- r_7 f
Signature of Ow7ne 's gRe esentative
Problems Found
Corrections Made
Date Corrected By
WASHINGTON ALARM, INC.
1253 South Jackson Street
Seattle, WA 98144
Ph. (206) 328-1800 FAX (206) 328-6755
FOR THE CITY OF aVNQW'6�5,
Electrical Contractor's License No. WASHIAI282C3
SFD Examination Certificate No. UL Certificate No
6 FIRE ALARM SYSTEM CONFIDENCE TEST REPORT
C!P CENTRAL STATION TRANSMITTER TEST REPORT
Central Station Account No.
Occupied as (major tenant) beq-aa)W IQ C- b r) (Z Q-5 V W W
Address Al,,,e 1A) Zip Cd. !200-?-� Phone No. ri JA
Fire Department representative present
No. of initiating circuits 0 No. of signaling circuits ly
Type of test El Monthly Cl Quarterly 1:1 Semi -Ann I Annual Accept
Fire control panel manufacturer 15; 1 e e1A k Model No. 5 93 1,70
Central Station transmitter manufacturer Model No.
Battery voltage Z,5-� 7— volts Battery charger voltage 2-7 - *3 volts
Battery voltage under alarm load (with horns/bells sounding) volts
Transmitter tripped by which initiating circuit ISM n vn2v- ft, eA yz Is
CENTRAL STATION
FIRE
CONTROL
PANEL
TRANSMITTER
Smoke detectors cleaned?
System operates on AC power
Yes
No
ID
NA
Yes
D No
"Alarm Silence" results in tbl. sig.
Yes
No
QQ
NA
Yes
No
Loss of AC results in trouble signal
�-W Yes
No
NA
Yes
No
System operates on battery
W Yes
No
NA
Yes
No
All circuits checked for elec. supv.
Y) Yes
No
NA
Yes
No
Test meets manufacturer's specs.
Yes
No
NA
Yes
No
All auxiliary equipment operates
Yes
No
NA
Key to fire control panel available
Yes
No
NA
Operating instructions posted
Yes
No
NA
Test record posted at control panel
Yes
No
NA
r
Yes
ID No
Automatic time delay of general alarm
minutes
Time initiated 13: 5-0
Time received by Central
Station
EQUIPMENT TESTED
TYPE OF EQUIPMENT
NO. OF UNITS
TESTED
SATISFACTORY
YES NO NA
NO. OF UNITS
IN BUILDING
Bells, Op Chimes, Voice Alarms, Speakers, Water Gongs
z
Visual -Alarm Devices
7
Trouble Indicators
Heat Detectors
cZ
Smoke Detectors
Smoke Beams
Sprinkler Waterflow Alarms
Sprinkler Supervisory Switches
Manual Pull Stations
Ventilation Controls Operate
Annunciators
Elevator Recall
Fire Dampers/Smoke Dampers
Phone jacks
Automatic Door Release
1 Other
THIS IS TO CERTIFY THAT THIS FIRE ALARM SYSTEWCENTRAL STATION TRANSMITTER HAS BEEN PROPERLY TESTED AND INSPECTED FOR
RELIABILITY TO COVER THE ITEMS LISTED IN THIS REPORT, IS CONSISTENT WITH FIRE ALARM MAINTENANCE STANDARDS/MANUFACTURER-S
REQUIREMENTS, AND ALL CORRECTIONS HAVE/HAVE NOT BEEN MADE.
Signature of Inspect r Date 17--e) 116
Signature of Owner VRr!se`=tafive
Problems Fc
Corrections Made
Date Corrected By
.WASHINGTON ALARM, INC. FORTHECITYOF
1253 South Jackson Street
Seattle, WA 98144
Ph. (206) 328-1800 * FAX (206) 328-6755
Electrical Contractor's License No. WASHIA1282C3
SFD Examination Certificate No. UL Certificate No.
FIRE ALARM SYSTEM CONFIDENCE TEST REPORT
CENTRAL STATION TRANSMITTER TEST REPORT
Central Station Account No. Vow) 677
Occupied as (major tenant) e-Q 1) 0 Y04 eo 4 d_6
Address 22=1 10 q [) A -(A, �kV-4E_ I IJ -Zip Cd. Q Phone No. - N
Fire Department representative present N f4
No. of initiating circuits No. of signaling circuits
Type of test Q Monthly Quarterly ID Semi-Axinual Annual C3 Accept
Fire control panel manufacturer 15,' 4- A)k 14 ,- I r, 1A Model No.
Central Station transmitter manufacturer Model No.
Battery voltage ?,-volts Battery charger voltage 2, volts
Battery voltage under alarm load (with horns/bells sounding) - Z41 S - volts
Transmitter tripped by which initiating circuit S O&D V-p- _e. 1, " o,&As 1 F 0 U S
CENTRAL STATION
Smoke detectors cleaned? t Ig
FIRE CONTROL
PANEL
TRANSMITTER
System operates on AC power
1* Yes
No
NA
Yes
0
No
"Alarm Silence" results in tbl. sig.
0 Yes
No
NA
Yes
YJ
No
Loss of AC results in trouble signal
14 Yes
No
NA
Yes
0
No
System operates on battery
Yes
No
NA
Yes
No
All circuits checked for elec. supv.
Yes
No
NA
Yes
No
Test meets manufacturer's specs.
Yes
No
NA
Yes
No
All auxiliary equipment operates -
0 Yes
C3
No
NA
Key to fire control panel available
lu Yes
No
NA
Operating instructions posted
1P Yes
No
NA
Test record posted at control panel
10 Yes
No
NA
Yes
No
Automatic time delay of general alarm
minutes
Time initiated / 0 . I/ ___ Time received
by Central Station
EQUIPMENT TESTED
TYPE OF EQUIPMENT
NO. OF UNITS
TESTED
SATISFACTORY
YES NO NA
NO. OF UNITS
IN BUILDING
Bells, &Z Chimes, Voice Alarms, Speakers, Water Gongs
-2 1
X
7-1
Visual Alarm Devices
Trouble Indicators
Heat Detectors
(0
Smoke Detectors
-7-4
Smoke Beams
Sprinkler Waterflow Alarms
Sprinkler Supervisory Switches
Manual Pull Stations
Ventilation Controls Operate
Annunciators
Y--
Elevator Recall
Fire Dampers/Smoke Dampers
Phone jacks
Automatic Door Release
Other
THIS IS TO CERTIFY THAT THIS FIRE ALARM SYSTEWCENTRAL STATION TRANSMITTER HAS BEEN PROPERLY TESTED AND INSPECTED FOR
RELIABILITY TO COVER THE ITEMS LISTED IN THIS REPORT, IS CONSISTENT WITH FIRE ALARM MAINTENANCE STANDARDS/MANIJFACTURER'S
REQUIREMENTS, AND ALL CORRECTIOPIS HAVE/HAVE NOT BEEN MA
'PE
Signature of Inspect Date !0 /,M /In
Signature of Owner(R7esentative
Problems F d
Corrections Made
Date Corrected By
Page 1 of I
Westfall, John
From: John J. Westfall Dwestfal I @fired istrictl org]
Sent: Thursday, April 22, 2010 3:24 PM
To: Westfall, John
Subject: FW: Security code for Sequoyah condos
From: Kelli Ewald [mailto:KEwald@snocom.org]
Sent: Thursday, April 22, 2010 12 ' :35 PM
To: Supervisors; John I Westfall
Subject: Security code for Sequoyah condos
Hi there, Sgt Cameron with Edmonds pd called today and wanted to update us with the security code for the
Sequoyah condos at 22910 90 AVE W. The code is *(STAR) 4250. The sergeant referred the'condo owner to
SNOPAC to update SCSO units as well.
Thankyou
Kelli Ewald
4/22/2010
Westfall, John
From: Smith, Mike
Sent: Wednesday, August 15, 2007 11:27 AM
To: Fire Dept Group
Subject: Numerous Issues jft
- M_W"
The fo)1ewjing---in-_for—m-a-t=- may be useful in an emergency response:
1) Tl(e Sequoyah Congpg§ formerly the Northwood access off of Edmonds way and 90th Ave W in the 22900 and 23000
block�-,��Oages of apartment to condo conversion. I would recommend you drive by/through the complex and
observe the dramatic changes- 25 trees have been removed, the limbs on the drive off of Edmonds Way will not tear the
tops of the rigs off, all the buildings have an offsite monitored automatic fire alarm with smokes and heats -remote
enunciator at the front door to the buildings with reset capabilities, each building will have its own FD LkBx, and the FDC's
to the standpipes in the stairwells are visible along with the yard hydrants. The contractor will be sending me an electronic
site plan for your viewing pleasure.
2) The Pt Edwards Condos are continuing at a good clip. Buildings 6 & 7 (41 and 31 Pine St) are going up fast. The two
500 gallon LPG tanks are back with the boiler for dry heat to the units during drywall work. The tanks are located on the
main drive just between the above two buildings. There are two new fire hydrants by these buildings and they are live. 24
hour security is still onsite.
3) The Gregory 505 5th Ave S has been approved for occupancy and is starting to fill up. FD LkBx is to the right of the
front door. Building features are automatic fire alarm/addressable/ with enunciator at front door with reset capabilities, an
intercom to the areas of refuge for stranded ADA people, sprinkled throughout with a dry system in the garage and wet
system in the retail and residential spaces. A combo for the garage gate for access will be added to the lockbox.
4) KUPC (Korean Church addition) 8505 240th St SW will be ready for occupancy soon. Building features include
automatic, monitored, addressable fire alarm with remote enunciator in lobby to include reset capabilities, sprinklered
throughout, voice evac in gym, FD LkBx's by the riser room SW corner and main entrance on the North side of building.
The basement is unfinished and will not be occupied at this time.
That's it for now. Call with questions.
Westfall, John
Frdrn: Tomberg, Thomas
Sent: Monday, September 25, 2006 4:45 PM
To: Westfall, John
Subject: FW: Construction at Northwood Apartments in Edmonds, WA
9-25-06
John. FYI. Thanks. TT
----- Original Message -----
From: Tomberg, Thomas
Sent: Monday, September 25, 2006 3:51 PM
To: Haakenson, Gary
Cc: Bowman, Duane; Carl, Linda
Subject: RE: Construction at Northwood Apartments in Edmonds, WA
9-25-06
We are doing what we can. Below are the minutes from the September 19 Staff Meeting re
Northwood Apartments.
11FM Westfall and has been working with Snohomish County Fire Marshalls Office Inspector
Gary Bontrager on the condo conversion at Northwood Apartments, 23015 Edmonds Way
(Esperance, Grid 055). Building A is the first of five multi -family buildings to undergo
residing, re -roofing, receive new windows and appliances. Dry standpipes and fire
extinguishers are the only fire protection equipment in the building. There are no
building alarm systems. many units remain occupied as remodeling continues. Unoccupied
units are supposed to be marked with an 11011 by the contractor."
Thanks. TT
----- Original Message -----
From: Haakenson, Gary
Sent: Monday, September 25, 2006 11:01 AM
To: 'Bridget Long'; savagemcl@yahoo.com
Cc: Tomberg, Thomas; Bowman, Duane; Carl, Linda
Subject: RE: Construction at Northwood Apartments in Edmonds, WA
Good morning Bridget, I'm sorry that you are having such a difficult time with your
situation. while your address may say "Edmonds", you are really not in Edmonds, you are in
Snohomish County or Esperance as many folks call it. we tried very hard last year to annex
the area into Edmonds but the voters in Esperance turned it town. You'll have to contact
Snohomish County with your concerns as we have no jurisdiction in your area. The Edmonds
Fire Department does serve you and please continue to call them for any aid calls or fire
concerns.
Sincerely,
Edmonds Mayor Gary Haakenson
----- Original Message -----
From: Bridget Long [mailto:keavyocleary@yahoo.com]
Sent: Saturday, September 23, 2006 7:01 PM
To: savagemcl@yahoo.com
Subject: Construction at Northwood Apartments in Edmonds, WA
Hello,
My name is Bridget Lombardo and I am a tenant at
Northwood Apartments at 23015 Edmonds Way, Edmonds,
Washington. I want to let you know what is happening
to our homes here.
1
In early July there were rumors that our apartments
were being sold to people that were intending to turn
the buildings into Condos. Those rumors were
confirmed by our management team a few days later. By
the end of July the sale was final and they began
'construction with little notice to the residents.
They began by tearing up the plant life and removing
siding. It is in our rental agreement that quiet
hours are between lOpm and 8am, the construction
typically began around 7:30am. The removal of siding
is very loud and for people that work nights, their
sleep was disrupted a great deal. This also caused
the bottom edge of our windows to separate from the
wall by approximately an inch and the owners refused
to fix them explaining that we will be getting new
windows shortly. We have not as of September 23,
2006. While the siding was being removed some tenants
moved out and the construction people began doing
asbestos removal from their apartments, while units in
the same building remained occupied. Their safety
precautions for this was to place plastic over the
doorways and wear haz-mat suits, but the construction
people cut slits in the plastic to gain entrance to
the unit and left them open and of course no haz-mat
suits were offered to tenants.
once a large cluster of units were vacant, they closed
off large sections of hallways with no notice at all
to remove the asbestos from the hallways cutting off
our immediate access to the main entrance, elevators
and emergency exits. (There were a few exits
available, but none with elevator access in a building populated mostly by seniors) once
the main entrances were available again the nearest emergency exits were systematically
closed off.
The removal of asbestos also requires industrial fans
to be on 24 hours a day in each unit for several days,
causing a great deal of noise and vibration in the
surrounding units. The construction has also had the
hallways closed off for plaster to be put on the walls
in the hallways (again with no notice) and the plaster
dust requires that the construction people wear
respirators, but none have been provided to the
tenants.
There are holes in the walls of the hallways exposing
wiring and insulation. The appliances from the vacant
units are lined up along the hallways, stacked in the
communal laundry rooms or heaped in the parking lot.
There has been no attempt to chain off the
refrigerator doors to prevent children from becoming
stuck in them. The tenants have also had to call the
fire department several times to have the dumpsters
removed from the fire lanes in front of our building.
As a result of these above situations and more, my
husband and I have both had severe respiratory and
skin disorders since the construction began as have
many of the tenants we have spoken to, one of which
has since died. People with Asthma have been rushed
to the emergency room due to the dust and asbestos
that are in the air.
People need to know that this is happening and that no
renter is safe from this fate. We had so little
warning to any of this and the owners only gave the
2
official notice of intent to convert the building into
condos on August 28, 2006 giving people until November
28 to be out of the building, but having tenants has
not stopped them from destroying our homes before we
have had a chance to leave, neither have they offered
any aid or compensation to tenants too old, weak or
poor to move themselves out.
Thank you for reading this. If you have any
questions, please feel free to call me at
206-713-5004.
-Bridget Lombardo
Do You Yahoo!?
Tired of spam? Yahoo! Mail has the best spam protection around
http://mail.yahoo.com
3
Westfall, John
From:
Westfall, John
Sent:
Wednesday, September 20, 2006 10:06 AM
To:
'Bontrager, Gary'; 'Tangen, Ron'
Cc:
Smith, Mike
Subject:
Northwood Apts
Thanks for the alert on this one fellows. I distributed the information to the crews and they are prepared to respond to the
construction conditions.
I am forwarding a request from the firefighters is can we assure that the suite numbering is in sequence by floor (#101,
201, 301, etc..) vs. the current way the buildings have been (#1 - #43). The latter makes it difficult to identify the most
direct route to the problem in emergencies.
Thank you,
John
425 771-0213
Message
Wesffall, John
Page I of I
From: Westfall, John
Sent: Thursday, September 14, 2006 4:37 PM
To: 'Bontrager, Gary'
Cc: Smith, Mike; Tomberg, Thomas
Subject: RE: Northwood Apartments
Thank you, Gary.
----- Original Message -----
From: Bontrager, Gary [mailto:Gbontrager@co.snohomish.wa.us]
Sent: Thursday, September 14, 2006 4:32 PM
To: Westfall, John; ssherman@flredistrictl.org
Cc: Mickiewicz, Mike
Subject: Northwood Apartments
Jeff agreed to the following conditions:
1. Restore all exit signs and emergency light as soon as possible.
2. Repair all lights in exit ways (stairs and hallways)
3. Replace any missing fire extinguishers
4. Limit fire doors being blocked open. Conduct a walk around inspection prior to the end of each shift to insure all
doors are closed.
5. Develop a fire plan if any of the exit ways are going to be block that effect tenant(s), to include having a fire
watch.
6. Mark all units not occupied. Doors painted with the universal sign of NO and the windows marked with a red
sign reading "Not occupied".
Follow-up surprise inspections will be conducted for the safety of the occupants.
Gary Bontrager, Fire Inspector
Office of the Snohomish County Fire Marshal
gbontrager,@co.snohomish.wa.us
(425) 388-3557, ext. 2231
9/14/2006
Westfalli John
From: Westfall, John
Sent: Thursday, September 14, 2006 9:35 AM
To: Chief Tomberg
Subject: Northwood Apts 23015 Edrn Way
Chief:
For your information I've been working with Gary Bontrager on some issues out of Edmonds jurisdiction but within
Esperance response area. I am involved because the life safety concerns there affect our firefighters, their safety and the
increased risk of response due to construction conditions. I believe we have the "A" building in a condition where they can
continue the work while occupied. This is the first of five building conversions from apartment to condominium.
I'm telling you in case Sno County or the GC voices any concerns.
John
Northwood Apts
B015 Edmonds W..
t'l kA ( t., /-AA J�t /tf C-
3 f35 F-4 9 9
'i
Wesffall, John
From: Westfall, John
Sent: Wednesday, September 13, 2006 4:07 PM
To: Fire Dept Group
Subject: Northwood Apts 23015 Edmonds Wy Bldg A Grid 055
Members:
Ref: Grid 055/FS20 Northwood Apts 23015 Edmonds Wy Bldg A
I've fielded concerns from a tenant regarding an apt -condo conversion project underway here. I've discussed my concerns
with the general contractor and I have calls into Sno County.
FYI Bldg A is a 3-story wood -framed 43 unit multi -family building with 26 units are occupied. No fire protection or detection
only dry standpipe. Scope of work includes residing, reroofing, changing windows and appliances.
You may receive a call this night regarding exiting concernslissues. The contractor has been on site until 2100 some
evenings. Please respond and take note of what you find. Contact Snohomish County Investigator and myself.
Thanks,
FM
,70 (O-C 5-)l (7- Z_ _13:-
q tl I for. O-e�N"- ""111 0a. C5,p
D
6 C "_4Ttc? I
L-/1 L (_
At C—
L—, 7b/- -r
I
Message
Wesffall, John
Page I of I
Subject: FW: Northwood Apartments 23015 Edmonds Way
Dry standpipe service due 10/2006
No fire alarm. FA required in existing IFC 907.3.1.7
No fire sprinkler. Not required.
Un block fire/smoke doors from corridors and seperating fire areas.
Repair or replace exit signs that are not illuminated and without backup.
Repair or replace lights in paths of egress.
Replace missing portable fire extinguishers.
24 occupied suites out of 41 units -exits and required separations must be in place.
Contractor identify Fire Prevention Program Superintendent per IFC Section 1408
Contractor provide 24 hour contact information on -site.
Contractor post permits.
----- Original Message -----
From: Steve Sherman [mailto:sSherman@firedistrictl.org]
Sent: Tuesday, September 12, 2006 4: 10 PM
To: Westfall, John
Subject: FW: Nortwood Apartments
For your info
From: Bontrager, Gary [mailto:Gbontrager@co.snohomish.wa.us]
Sent: Tuesday, September 12, 2006 10:28 AM
To: Steve Sherman
Subject: Nortwood Apartments
Per our telephone conversation:
Nothwood Apts
23015 Edmonds Way
Building A being remodeled into condo's. Building is occupied.
Gary Bontrager, Fire Inspector
Office of the Snohomish County Fire Marhshal
gbontrager@co.snohomish.wa.us
(425) 388-3557, ext. 2231
9/18/2006