Loading...
234 2ND AVE N.PDFIIIIIIIIIIII 4789 234 2ND AVE N ADDRESS: �,rlcl AVO-7, BUILDING PERMIT (NEW STRUCTURE): COVENANTS (RECORDED) FOR: CRITICAL AREAS: —DETERMINATION: E] Conditional Waiver F 00aiver ]Study Required XW DISCRETIONARY PERMIT #'S: DRAINAGE PLAN DATED: 12,1)j,4 lob , -Dyu-tarme-) &n1w-e jz PARKING AGREEMENTS DATED: EASEMENT(S) RECORDED FOR: PLANNING DATA CHECKLIST DATED: SCALED PLOT PLAN DATED: SEWER LID FEE $: LID #: SHORT PLAT FILE: LOT: BLOCK: SIDE SEWER AS BUILT DATED: SIDE SEWER PERMIT(S) #: SOILS REPORT DA STREET USE / ENCROACHMENT PERMIT #: WATER METER TAP CARD DATED: OTHER: Ct y/ L RA Af5 - I LATEMP\DSrs\Forms\Street File Checklist.doc City of Edmonds Permit No:(9/ 'RIGHT-OF-WAY CONSTRUCTION PERMIT Issue Date: lo A. Address or Vicinity of Construction: A ;,,'4+ ALI— I-IWF-- IV B. Type of Work (be specific): I MSrALLtd7o� 6C' UII,UTIJE�51 WAA41ftlEAt VNE C. Contractor: Mailing Address: 7 .21, .) 7 State License #:- D. Building Permit #(if applicable) > Contact: - Phone: Liability Insurance: Bond: $ Side Sewer Permit # (if applicable): E. F-1 Commercial Subdivision City Project F� EUC (PUD, GTE,PSE, CHAMBERS, OVWD) Multi -Family Single Family F-1 Other INSPECTOR- IAS66WA� F. PANiEMENT: ES NO G. SIZE OF CUT x H. Charp: $ CONCRETE CUT: ES F� No �yy APPLICANT TO READ AND SIGN IDEMNITY. Applicant understands by hislher signature to this application helshe holds the City of Edmonds harmlessftom �injuries, damages or claims � of any kind or description whatsoever, foreseen or u f rese en, that may be made against the City, of EdTonds or any -of iis departm�ents or employees, including but,hot limited"to the"defense of any legal proceedings including defense costs and �attorneyfqes by reason ofgranting this permit. THE CONTRA CTOR IS RESPONSIBLE FOR. WORKMANSHIP. AND MA TERIALS FOR A PERIOD OF ONE YEAR FOLLOWING THE FINAL INSPECTION AND ACCEPTANCE OF THE WORK. ESTIMATED RESTORATION FEES WILL BE HELD UNTIL THE.FINAL STREET PATCH IS COMPLETED BY CITY FORCES, AT WHICH TIME A DEBIT OR CREDIT WILL BE PROCESSED FOR ISSUANCE TO THE APPLICANT. Traffic control and public safety shall be in accordance with City regulations as required by the'City Engineer. Every flagger must be trained as required by (WAC) 296-155-jO5 and must have certification verifying completion of the required training in their possession. Restoration is to be in accordance with City, codes. All street -cut trench work shall be patched with asphalt or City - approved material prior to the ' end of the workday - NO EX.CEPTIONS. 4 Three sets of construction drawings of proposed work are required with the permit application. IHAVEREAD THE ABOVE STATEMENTS AND UNDERSTAND THE PERMIT REQUIREMENTS AND,ACKNOWLEDGE, THATIMUSTMAKE THE PINK COPY OF�THE PERMIT AVAILABLE ONSITEATALL TIMES FOR INSPECTIONS Signature:— Date:,? 6 '(Contractor or Agent) CALL DIAL -A -DIG (1-800-424-5555) PRIOR TO BEGINNING WORK FOR CITY USE ONLY Approvedby:z/wt,�e, Righ�-of-way Fee-&) + ,Time �Authoriied:'Void-After6&6r-->,03tiwir- Disiuption Fee/Fund,111: ',Special Conditions: Restorati F 911, ee: p6z;_;634?12��Q ell. 7' Urt Irrs: C4ui L.3 Total Fee:. 145. R,6ceiptNo': V ku zros Issued by:, y UPON COMPLETION OF PERMITTED WORKAN ENGINEERING FINAL INSPECTION IS REQUIRED PER CHAPTER 18.00 OF THE EDMONDS COMMUNITY'D, EVELOPMENT CODE. FINAL APPROVAL OF PERMITTED WORK. INSPECTOR'S SIGNATURE -DATE: For inspection requirements see Engineering Information*.Handout. MNO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE 150 IN5TALL III NEW :211 C13 Lu �S)l > Lu INTEK5ECTION OF DKIVEWAY & CENTERLINE OF RIGHT -OF- Edmonds WAY 1.4 ho a4r, A YJ d4 rj4- I W frrc EXIOTING HOU5E TO 15E KEMOVEO — — — — — — — — — — — \\--- NEW �\RIPLEX 92.50 FT Hl(-,H OD,EPY ,EXIIJI�C2 qll)E;W�LK %1\1' 2 (b �,3 120.00, Street 4 00-' 1.1.50" (:S 5 < T. 6FT CEDAP', FENCED FNCL05UP,4 EXISTING CONDOMINIUM �= \j < DRAINAG Lu < p"Zil DATUM KIM -13#3 50.20 PARKIN APPROVED By PLANNING & PLOT PLAN SCALE: 1"=20' uj co < X 0- LLJ < RECEIVED DEC 1 4 2000 DEVELOPMENT SESVICES CTR. CITY OF EDMONDS HEIGHT CALCULATION5 A 52.88 [3 56.21' c 6.60, P 52.34' 54.51'=- AVEKAGE GRADE EX15TING TOFO FKOFO5EI) TOFO Dennis M. Bruce, RE. m.S.C.E., M.B.A. Geotechnical/ Civil Engineer December 12, 2000 RECEIVED City of Edmonds DEC- 14 2000 c/o Michel Construction, Inc. 7907 - 212th Street S.W. #102 DEVELOPMENT SERVICES CTR. CITY OF EDMONDS Edmonds, Washington 98026 C)/<- Subject:. Detailed Drainage Report Proposed 3-Unit Condominium at 234 Second Ave. N. -Referen.ces - Drainage desi I. gn plan, certified December 12, 2000 ly - Santa Barbara Unit Hydrograph calculations (attached) Criteria: Total site area equals 0. 1652 acres (7,200 square feet). Existing conditions are assumed to be fixed grass or meadow. The existing impervious surface is e cludid per City of Edmonds stipulations. Storm detention required is the 10 year and 100 year undeveloped match, t-*'- based on City of Edmonds Drainage Code, Section 18.30.060 (1)(c). Assume Type "C" soils (typically such as Alderwood or Tokul G.S.L., Hydrologic Group "C"). Assume C(n) initial to b e ,81 for grass or pasture. Assume C(n) final to be .85 for landscaped areas and .98 for roof top. L-1 = 138'at a slope of -0.0454 T(c) = 13.34 minutes P (2-year) = 1.5 inch per hour P (10-year) = 2.1 inches per hour �10 P (1 00-year) = 3.2 inches per hour 3,0 Proposed impervious area = 5,340 square feet, or 0. 122 acres Proposed pervious area =. 1,860 square feet, or 0.042 acres SOILS - FOUNDATIONS - SITE DEVELOPMENT - INSPECTION - DRAINAGE - DESIGN& PERMIT - LEGAL P.O. Box 55502 - Shoreline, Washington 98155 - (206) 546-9217 - FAX 546-8442 Re: Michel Construction, Drainage Report, 234 Second Ave. N., Edmonds Page two . The runoff from the proposed three -unit project is estimated by the SBUH method. The reduction in release rate from the developed to the undeveloped case is accomplished using a simple two orifice configuration per plan. Q (allowed) 0 (developed) Q, (pipe release) 2-year n/a n/a n/a 1 0-year 0.016 cfs 0.060 cfs 0.016 cfs 1 00-year 0.045 cfs 0.098 cfs 0.044 cfs Design conclusions based on SBUH site model: 36" diameter pipe outlet invert will be at Elevation 47.5'.- Total detention for the project is required to be 318 cubic feet (stored in 50 lineal feet of 36" CMP or equivalent). - The restrictor shall be set in a conventional 54" size restrictor manhole. The 54" manholes, in series, will hold a total of 48.6 cubic feet of storm water. The remaining detention shall be handled in a single 36" diameter culvert, PVC or CMP. The length of the run of pipe shall be 43 lineal feet. Orifice No. 1 is 0.66 inches in diameter at Elevation 45.0 feet, (with the outlet elevation as described above). - Orifice No. 2 diameter is 1.03" at Elevation 49.4'. The 6" riser overflow elevation will be at Elevation 50.2. The riser will release the Q (100 developed flow), and more, before reaching Elevation 50.2 (or less than 0.1 foot above the riserin the event of a clogging problem with the restrictor). Concluslons Total project storage volume of 318 cubic feet is achieved via underground detention pipe system. Re: Michel Construction, Drainage Report, 234 Second Ave. N., Edmonds Page three The designed drainage plan has effectively incorporated the SBUH design release rates for. the project. - The City of Edmonds drainage requirements have been met. The project runoff enters the downstream storm system at CB No. 7, on Second Avenue North, and flows southerly to Manhole No. 7-13 (at the intersection of Second and Bell Streets). The flow thereafter turns westerly to Brackett's Landing North Park (B.L.N.P.), and subsequently into Puget Sound. If there are any questionsi do not hesitate to call. WA ta 171 *eel PIRES UMI 9 0& 11 DMB:vIb Dennis M. B ruce, P.E. Geotechnical / Drainage Engineer Dennis M. Bruce, P.E. DEPC 14 2000 C C Geotec"' "'bMiZagineer M.S.C.E., M.B.A. 0 M 1(2 j4 e L #JS 7- BASIN ID: B002 SBUH METHODOLOGY TOTAL AREA ....... RAiNPALL TYPIS ...... PRECIPITATION .... : ,TIME INTERVAL ...... CP BASIN SUMMARY .R34 NAME: undeveloped 2-year ------------- % 0.16 Acres BASEFLOWS#- .TYPEIA j..50 inches ARSA.-:. 1.0.00-min CN. - - TC....#:. 0.00 cfs PERV .0. 16 Acre$ 81.00 13.34 min ABSTRACTION COEFF: 0.20 TCReaLch - Sheet L: 138.00 ns:0-150()_p2yr: 1.50 9:0.0454 pEAK RATE. 0,00 cfe VOL:. 0.00 AC it TIME: 490 min BASIN ID: B010 SBUH METHODOLOGY TOTAL AREA ....... RAINFALL TYPE ..... PRECIPITATION .... : TIME INTERVAL .... : .NAME: undeveloped 10-year 0.16 Acres. BASEFLOWS: . 0.00 C fs TYP81A I PERV 2.10 inches AREA..: 0.16 Acres lo.00 min CN....: 81.00 TC.... : 13-.34 min ABSTRACTION COEFF: 0.20 - yr; 1.50 s:0.0454. TcReach - Sheet L.- 138.00 ns:0.1500 jp2 PEAK RATE; 0.02 CfS VOL: 0.01 Ac _ ft TIME: 480 min BASIN ID: B100 SBUH METHODOLOGY TOTAL�AREA ....... RAINFALL TYPE .... PRECIPITATION....: Tjj413 INT13RVAL. . - - - NAME: Undeveloped 100-.year o.iG Acres TYPEIA 3.20 inches 10. 00 MiLl BASEFLOWS: AREA.. ; CN....; TC.... : 0. 00 cf a PERV 0.16 Acres 81.00 13.34 Min ARSTSUACTION COEFF 0.20 L: 138.00 ns:0.1500 p2yr: 1.60 s:u.u4b4 Sheut _ ft TIME: 480 min PEAK RATE: 0.04.cfs VOL: 0.02 Ac BASIN ID: D002 SBUR METHODOLOGY TOTAL AREA ....... RAINFALL TYPE....-: PRECIPITATION .... : TIME INTERVAL .... : NAME: Developed 2-year 0.16 Acres TYPRIA 1.50 inches jo. 00 min BASEFLOWS: TC. - - i: 0.00 cgs PERV 0.04 Acres 86.00 6.30 min IMP - 0.00 Acres O.QO o. oo tnin ABSTRACTION COEFF: 0.20 TcReach Sheet . L: 138.00 ns:0.2400 p2yr: 1.50.s:0.0454 0.04 Cfs. VOL: 0.01 Ac-ft TIM: 480 min pEAX RATE IMP 0.00 Acres 0.00 o.00 min IMP 0.00 Acres 0.00 � 0.00 min IMP 0.12 Acres 98.00 6. 3 0 min SOILS . FOUNDATIONS - SITE DEVELOPMENT - INSPECTION - DRAINAGE - DESIGN & PERMIT - LEGAL P.O. Box 55502 - Shoreline, Washington 98155 - (206) 546-9217 - FAX 546-8442 4 Dennis M. Bruce,. RE. Geotechnical / Civil - Engineer lwll.&C�;E., M.B,.;A- ............. BASIN SUMMARY BASIN ID: D010 NAME: Developed 10-year SBUH METHODOLOGY TOTAL AREA 6 0.16 Acres- BASEFLOWS: 0.00 CfS. RAINFALL TYPE..-: TYPE1A PERV IMP PRECIPITATION .... : 2.10 inches AREA..: 0.04 Acres 0.12 Acres TImE INTERVAL .... : 10'.00 min CN.... TC....: 86.00 6.30 min 98.00 6.30 min ABSTRACTION COEFF, TcReach -�iSheet 0.20 L:. 138.00 ns:0.2400 p2yr: i-50 B:0.0454 PEAK RATE: o.o6 cfs -VOL: 0.02 AC-ft TIME: 480min BASIN 1D: D100 SBUK METHODOLOGY TOTAL AREA ....... RAINFALL TYPE....: PRECIPITATION....: T1149 INTERVAL.... : NAME: Developed 100-year 0.16 Acres TYPE1A 3.20 inches 10. 00 min BASEFLOWS: AREA., . : CN.... : TC. - ... , 0.00 cfs PERV 0*04 Acres 86:00 6.30 min ABSTRACTION COEFF: 0.20 TcReach -' Sheet L- 138.00 nB:0.2400 p2yr: 1.50 S:0.0454 PEAK RATE: 0.10 CfB VOL: 0.04 Ac-ft TIME: 480 min a a HYDROGRAPH SUMMARY PEAK TIME VOLUME HYD RUNOFF OF OF Contrib MUM RATE PEAK HYDRO Area cfs min. cf\AcFt Acres 1 0.005 490 189 cf 0.16 2 0.016 480 401 Of 0.16 3 0.045 480 880 cf 0.16 4 0.039 480 642 cf 0.16 5 0.060 480 911 cf 0.16 6 .0.098 480 1594 cf 0.16 7 0.014 690 880 cf 0.16 ,a 0.016. 620 971 cf 0.16 9 0.044 520 1594 cf 0.16 imp. 0.12 Acres 98.00 6.30 min SOILS . FOUNDATIONS - SITE DEVELOPMENT INSPECTION - DRAINAGE - DESIGN & PERMIT - LEGAL P.O. Box 55502 - Shoreline, Washington 98155 - (206) 546-921T - FAX 54643442 Dennis M. Bruce,. RE. M.S.C.E., M.B.A. Geotechnical/ Civil- Engineer.. STAGE STORAG TABLE UNDERGROUND PIPE ID No. P01A Dencription: Ifill 9q0valent Pipe Diameter: 3.00 ft. Length: 50.00 ft, slope... 0.0050 ft/ft upstr: dnatr: STAGE ( ---- STORAGE- STAGE ( ---- STORAGE ---- > STAGE < ---- STORAGE ---- > STAGE ---- STORAGI--..>. (f 0 --- ef--- --Ac-pt- (ft) ---ef --- -- AC -Ft. (f 0 --Ac-pt- (ft) -.AC-Ft- 41.50 0,0000 0.0000 48.40 72,794 0.0011 49.30 202.81 0.0047 50-20 322.02 .0,0074- 47.60 0.7230 0.0000 48.50 86.112 '0.0020 49,40 217.59 0.0050 50.30 331.75 0.0076 47.70 4.0476 0,0001 48.60 99.896 0.0023 49.50 232.17 0.0053 50.40 340.09 0.0078, 41.60 9.0393 0.0002 48-70 114.06 0.0026 49.60 246.49 0.0057 50.50 346.10 .010080 47.90 17.310 0,0004 48-80 128.52 0.0030 49.70 260.48 0.0060 $0.60 35i.45 0.0081 48.00 26.393 0.0006 40.90 143.21 0.0033 49.80 274.04 0.0063 50-70 151-31 0.0081 48.10 36.688 0,0008 49.00 158-05 0.0036 49.90 287.09 0.0066 50.80 353.43 0.0081 48.20 47..960 0,0011 49.10 172.98 0,0040 50.00 299.52 0.0069 50,90, 353.43 0.,0081 48.30 60,039 0.0014 49.20 187.92 0.0043 50.10 311.22 0.0071 STAGE DISCHARGE TABLE ----------- MULTIPLE ORIFICE ID No. R01A Description: 10-year outlet Outlet Elev:- .47.50 Elev: 45.00 ft orifice Diameter: 0.6606 in. Elev: 49.40 ft Orifice 2.Diameter: 1.0313 in. STAGE (-DISCHARGE --- > STAGE <--DISCURGE-) STAGE <--DISCHARGE --- STAGE 0-DISCHARGI --- (ft) --.Cfo -- ------- (ft) ... cfs -- ------- (ft) ... cft -- ------- (ft) --- ell .. ....... '41 50 0,0000 48.30 0,0106 49.10 0.0150 49.90 0.0382 48.40 0.0112 49.20 0.0154 50.00 0.0411 47.60 0.0037 48.50 0.0118 49.30 0.0159 50.10 0.0432 47.70 0.003 49.40 0.0163 50.20 0.0453 47.80 0.0065 48-60 0.0124 41.90 0,0075 (8.70 0,0130 49.50 0.0259 $0.30 0.0472 46,00 0.0084 48-80 0.0135 49.60 0.0301 50.40 0.0490 48.10 0,0092 40.90 0.0140 49.70 0.0334 50.50 0.0508 48.20 0.0099 49.00 0.0145 49.80 0,0362 SOILS FOUNDATIONS - SITE DEVELOPMENT - INSPECTION - DRAINAGE , DESIG N a PERMIT LEGAL P.O. Box 55502 - S horeline, Washington 98155 - (206) 546-9217 - FAX 546-8442 Dennis M. Bruce,. P.E. Geotechnical /Civil Engineer M.S.C.E., M.B.A. ZZ STAGE DISCHARGE TA33LE RISER DISCHARGE 1. ID No R02A Description: 611 Riser Riser Diameter (in): 6.00 elev: 50.20 ft weir Coefficient ... : 9.739 height: 50.60 ft Orif Coefficient ... : 3.1782 increm: 0.1.0 ft STAGE STAGE (--DISCBkRGE --- > STAGE (--DISCHARGR --- ) STAGE (--DISCHARGE --- (ft . ) ... cis-. ...... Aft) ... Cts .... ....... (10. ..-Cis ... ....... (it) ---CIS ---------- =%ZC=Zt= C :Z=z z =Z za Ila 2 A 2 an ona a 21A lk a a on a a a a am San a as a a VV Vzow a a or. rz==z=== ==Z a an Ada as a a as a am a a a V quo 50.20 0.0000 50.30 . 0.2990 50.50 0.5179 50.60 0.5980. 50.20 0.0000 50.40 0,4228 0.5980 STAGE DISCIiARGE TABLE COMBINATION DISCHARGE ID No. R03A Description: Orif ice Plus Riser Structure: R01A Structure: Structure: 902A structure: St3:Ucture: STAGE c.-DISCHARGE --- STAGE <--DISCHARGE --- > STAGE <--DISCURGE --- STAGE (..DISCHARGE---) fit) --- cis -- ------- (f 0 -..cis -- ------- ift) ---Cfr --- ------- ift) ---cis -- ------- *as As A: zX:==== === a 2 anal to an pang Naga==:: ====Zzzz2ftftz add 0VV2z:=::=:=:X2 &nuns Sam an 47.50 0,0000 48.30 0.0106 49.10 0.0150 49.90 0,0388 47.60 0.0037 46.40 0.0112 49.20 0.0154 50-00 0.0411 47.70 0,0053, 48.50 0.0118 49.30 0.0159 50.10 0,0432 47.80 0-000 48.60 0.0124 49.40 0.0163 50.20 . 0.0453 47.90 0.0075 48.70 0,0130 49.50 0.02S9 50.30 0.1462 48.00 0,0084' 48.80 0.0135 49.60 0.0301 50.40 0.4719 48.10 0.0092 48.90 0.0140 49.70 0.0334 50.50 0,5607 48.20 0.0099 49.00 0.0145 49,80 0.0362 50.60 0.6505 SOILS . FOUNDATIONS - SITE DEVELOPMENT - INSPECTION - DRAINAGE - DESIGN A PERMIT - LEGAL p.0. Box 55502 - Shoreline, Washington 98155 - (206) 546-9217 -' FAX 546-8442 Dennis M. Bruce,. P.E. v S) Geotechnical I Givil Engineer M.S.C.E., M.B.Ae - IN L VEL POOL TABLE SUMMARY XATCH INFLOW -$TO. -DIS- OBAV) STORAGE -;-Jd- <-STAGb A VOL'[d) ------- DESCRIPTION ......... ids) (C =a* ISBN W706611 49.31 8 '207.22 ef 10-year ...................... .0,02 0-06 POlA Ra'A 0.04 0,10 Polk Roll so -it 9 _11 100ayear ..................... . .1 Lf 3 LF-,) (41 4 3 01. (TT suj�mary a, 1asln Des, Cr ::::j:j1nd1v1dU01 Inawl, U-2-I notion Drainage Basin InTOFFTIatlon D -site Area n A 0. 1,15 Typp.Rf StOra a .0 I Im ra e Volume App iximate StO 3`18 AlderwooO­ soil types fpe GSL P ro-developed.lcunau 1406 . In- I 0 year 16 100 year hinn Iminbff Rate WAS COO 17405 70NAL r'EXPIRES 1 SOILS FOUNDATIONS - SITE DEVELOPMENT - INSPECTION. - DRAINAGE ' DESIGN a PERMIT - LEGAL P.O. Box 55502 - Shoreline, Washington 98155 - (206) 546-9217 - FAX 546-W2 Dennis M. Bruce, RE. M.S.C.E., M.B.A. Geotechnical/ Civil Engineer February 1, 2001 Michel Construction, Inc. Tly 7907 - 212th Street S.W. #102 UVP Edmonds, Washington 98026 Subject: Geotechnical Evaluation and Foundation Recommendations Proposed New Three -Unit 234 Second Avenue North, Edmonds This engineering report presents the results of a geotechnical evaluation of the property at 234 Second Avenue North, Edmonds, Washington. This evaluation was required due to owner / developer concerns, as well as City of Edmonds requirements. Vicinity map Site plan Site photographs 1421"itel-ftelli N-PA T"71 L-I'm t - T F The property at 234 Second Avenue North currently contains a single family residence. The residence reveals no evidence of any geotechnical distress: No settlements, no shifting, no foundation cracking, nor any erosional degradation were observed. The overall lot is essentially flat to gently sloping (slopes westerly towards Second Avenue North). The property outside the footprint of the existing house contains established lawn with occasional shrubbery. It is understood that project developer, Michel Construction, Inc., intends to demolish the existing single family residence, and construct a' new three -unit condominium project (see site plan). EVALUATION: In order to augment the existing site geotechnical information, soil test holes were h.and-.dug by this engineer on January 30, 2001 . . A total of seven (7) test holes SOILS - FOUNDATIONS - SITE DEVELOPMENT - INSPECTION - DRAINAGE - DESIGN & PERMIT - LEGAL P.O. Box 55502 - Shoreline, Washington 98155 - (206) 546-9217 FAX 546-8442 Michel Construction, 234 Second Avenue North Pagetwo were dug in the vicinity of the proposed building foundations. All seven test holes revealed similar subgrade conditions, namely: 0" to 611 Lawn, roots, and organic silt 6" to approx. 14" Light brown to reddish -brown sandy loam, grading to silty sand 14" to approx. 34" Increasingly dense sands with occasional (bottom of test holes) gravels No water was encountered in any of the seven test holes. All test hole walls remained vertical and stable. No sloughing or caving occurred. Kel ZI[qX1,1141*1 Z_&-JFA_J_=14P1Ti L!LM_1 Based on the findings of this investigation, and experience with similar sites in the area, the property at 234 Second Avenue North, Edmonds, Washington, is geotechnically approved for the proposed Michel Construction new three -unit condominium project, subject to the following: Standard reinforced continuous and spread footings. Allowable bearing pressure: 2,000 p.s.f. Equivalent fluid pressure of 35 p.c.f. is recommended for any retaining wall design provided drainage zone is inspected and verified by this engineer. For retaining wall design, use friction factor of 0.55 and passive pressure of 350 p.c.f. Geotechnical inspection by this engineer grior to any foundation concrete placement. The proposed structure can be supported on conventional continuous and spread footings bearing on undisturbed native soils or on structural fill placed above native soils. See the later sub -section entitled General Earthwork and Structural Fffill for structural fill placement and compaction recommendations. Continuous and individual spread footings should have minimum widths of eighteen (18) and twenty- four (24) inches, respectively, and should be bottomed at least eighteen (18) inches below the lower adjacent finish ground surface. Depending on the final site grades, some overexcavation may be required below footings to expose competent native soils. Unless lean concrete is used to fill 0 . 0 Michel Construction, 234 Second Avenue North Page three the over excavated hole, the width of the overexcavation at the bottom must be at least as wide as the sum of two times the depth of the overexcavation and the footing width. For example, an overexcavation extending two feet below the bottom of a three400t wide footing must be at least seven feet wide at the base of the excavation. Footings constructed according to the above recommendations may be designed for an allowable soil bearing pressure of three thousand (3,000) pounds per square foot (p.s.f.). A one-third increase in this design bearing pressure may be used when considering short-term wind or seismic loads. For the above design criteria, it is anticipated that total post -construction settlement of footings founded on competent, native soils (or on structural fill up to five (5) feet in thickness) will be about one-half inch, with differential settlements on the order of one -quarter inch. . Lateral loads due to wind or seismic forces may be resisted by friction between the foundations and the bearing soils, or by passive earth pressure acting on the vertical, embedded portions of the foundations. For the latter condition, the foundations must either be poured directly against undisturbed soil or the backfill placed around the outside of the foundation must be level structural fill. We, recommend the following design values be used for the foundation's resistance to lateral loading: Coefficient of Friction Passive Earth Pressure Where: 0.55 350 p.c.f. (1) p.c.f. is pounds per cubic foot. (2) Passive earth pressure is computed using the equivalent fluid density. We recommend that a safety factor of at least 1.5 be, used for designof the foundation's resistance to lateral loading. Slab -on -grade floors may be supported on undisturbed, competent native soils or on structural fill. The slabs may be supported on the existing soils provided these soils can be recompacted prior to placement of the free -draining sand or gravel underneath the slab. This sand and gravel layer should be a minimum of four (4) inches thick. We also recommend using a vapor barrier such as 6-mil. plastic membrane beneath the slab with minimum overlaps of 12 inches for sealing purposes. Michel Construction, 234 Second Avenue North Page four PERMANENT FOUNDATION AND RETAINING WALLS: Retaining walls backfilled on one side only should be designed to resist lateral earth pressures imposed by the soils retained by these structures. The following recommended design parameters are for walls less than twelve (12) feet in height which restrain level backfill: Active Earth Pressure* Passive Earth Pressure Coefficient of Friction Soil Unit Weight Where: 1R0qrGr11kV1._1, 35 p.c.f. 350 p.c.f. 0.55 125 p.c.f. (1) p.c.f. is pounds per cubic foot (2) Active and passive earth pressures are computed using equivalent fluid densities. For restrained walls which cannot deflect at least 0.002 times the wall height, a uniform lateral pressure of one hundred (100 p.s'.f. should be added to the active equivalent fluid pressure).: The values given above are to be used for design of permanent foundation and retaining walls only. An appropriate safety factor should be applied when designing the walls. We recommend using a safety factor of at least 1.5 for overturning and sliding. The above design values do not include the effects of any hydrostatic pressures behind the walls and assume that no surcharge slopes or loads will bef placed above the walls. If these conditions exist, then those pressures should be added to the above lateral pressures. Also, if sloping backfill is desired behind the walls, then we will need to be given the wall dimensions and slope of the backfill in order to provide the appropriate design earth pressures. Heavy construction equipment should not be operated behind -retaining and foundation walls within a distance equal to the height of the wall, unless the walls are designed for the additional lateral pressures resulting from the equipment. Placement and compaction of retaining wall backfill should be accomplished with hand -operated equipment. Michel Construction, 234 Second Avenue North Page five Retaining Wall Backfill Backfill placed within eighteen (18) inches of any retaining or foundation walls should be free -draining structural fill containing no organics. This backfill should contain no more than five (5) percent silt or clay particles and have no particles greater than four (4) inches in diameter. The percentage of particles passing the No. 4 sieve should be between twenty-five (25) and seventy (70) percent. Due to their high silt content, if the native soils are used as backfill, a drainage composite, such as Mirafi and Enkadrain, should be placed against the retaining walls. The drainage composites should be hydraulically connected to the foundation drain system. the purpose of these backf ill requirements is to assure that the design criteria for the retaining wall as not exceeded because of a build-up of hydrostatic pressure behind the wall. The subsection entitled General Earthwork and Structural Fill contains recommendations regarding placement and compaction of structural fill behind retaining and foundation walls. In no case should excavation slopes be greater than the limits specified in local, state and national government safety regulations. Temporary cuts up to a height of four (4) feet deep in unsaturated soils may be vertical. For temporary cuts having a height greater than four (4) feet, the cut should have an inclination no steeper than 1:1 (Horizontal:Vertical) from the top of the slope to the bottom of the excavation. Under specIf Ic recommendations by the geotechnical engineer, excavation cuts may be modified for site conditions. All permanent cuts into native soils should be inclined no steeper than 2:1 (H:V). Fill slopes should not exceed 1:1 (H:V). It is important to note that sands do cave suddenly, and without warning. The contractors should be made aware of this potential hazard. Water should not be allowed to flow uncontrolled over the top of any temporary or permanent slope. All permanently exposed slopes should be seeded with an appropriate species of vegetation to reduce erosion and improve stability of the surficial layer of soil. IA.; V 11 � Y-1441161031" A Footing drains are recommended at the base of all footings and retaining walls. These drains should be surrounded by at least six (6) inches of one -inch -minus washed rock wrapped in non -woven geotextile filter fabric (Mirafi 140N, Supac 4NP, or similar material). At the highest point, the perforated pipe invert should be at least as 0 0 Michel Construction, 234 Second Avenue North Page six low as the bottom of the footing and it should be sloped for drainage. All roof and surface water drains must be kept separate from the foundation drain system. No groundwater was observed in any of the seven test holes during the field work. Seepage into the planned excavation is possible, and likely if excavation occurs during winter months, and if encountered should be drained away from the site by use of drainage ditches, perforated pipe, French drains, or by pumping from sumps interconnected by shallow connector trenches at the bottom of the excavation. The excavation and site should be graded so that surface water is directed off * the site and away from the tops of slopes. Water should not be allowed to stand in any area where foundations, slabs, or pavements are to be constructed. Any exposed slopes to be covered with plastic to minimize erosion. Final site grading in areas adjacent to buildings should be sloped at least two (2) percent away from the building, except where the area adjacent to the building is paved. The proposed building and pavement areas should be stripped and cleared of all surface vegetation, all organic matter, and other deleterious material. The stripped or removed materials should not be mixed with any materials to be used as structural fill. Structural fill is defined as any fill placed under the building, behind permanent retainingor foundation walls, or in other areas where the underlying soils needs to support loads. This engineer should observe site conditions during and after excavation prior to placement of any structural fill. All structural fill should be placed in horizontal lifts with a moisture content at or near the optimum moisture content. The optimum moisture content is that moisture content which results in the greatest compacted dry density. The moisture content of fill soils is very important and must be closely controlled during the filling and compaction process. . The allowable thickness of the fill lift will depend on the material type, compaction equipment, and the number of passes made to compact the lift. In no case should the lifts exceed twelve (12) inches in loose thickness. The following table presents recommended relative compaction for structural fill: 0 Michel Construction, 234 Second Avenue North Page seven RKOM-t z 0 1=6 #M1111:04 =H- I Beneath footings, slabs or walkways Behind retaining walls Beneath pavements I In MITI-,", 1 zmum- W91*1 I 11 Pv� - 0 1 Mau 95% 90% 95% for upper 12 inches of subgrade, 90% below that level Where: Minimum relative compaction is the ratio, expressed in percentages, of the compacted dry density to the maximum dry density, as determined in. accordance with ASTM-Test Designation D-1557-78 (Modified Proctor). Use of On -Site Solis If grading activities take place during wet weather, or when the silty, on -site soils are wet, site preparation costs may be higher because of delays due to rains and the potential need to import granular fill. The on -site soils are generally silty and thus are moisture sensitive. Grading operations will be difficult when the moisture content of these soils exceeds the optimum moisture content. Moisture sensitive soils will also be susceptible to excessive softening and "pumping" from construction equipment traffic when the moisture content is greater than the optimum moisture content. Ideally, structural fill which is to be placed in wet weather should consist of a granular soil having no more than five (5) percent silt or clay particles. The percentage of particles passing the No. 200 sieve should be measured from that portion of the soil passing the three -quarter -inch sieve. The use of "some" on -site soils for fill material may be acceRtable if the upper organic materials is segregated and moisture contents are monitored by engineering inspection. No drainage problems were evident with the existing residence at 234 Second Avenue North. Surface runoff flows generally westerly into the existing City of 0 0 Michel Construction, 234 Second Avenue North Page eight Edmonds street storm system in Second Avenue North. The existing residence contains a gutter and downspout system that also flows into the existing storm system. The proposed new three -unit condominium will comply with City of Edmonds drainage requirements and this engineer's detailed drainage calculations and drainage plan (see drainage plan). All foundation concrete (footings, stem walls, slabs, any retaining walls, etc.) shall have a minimum cement content of 5-1/2 sacks per cubic yard of concrete mix. The recommendations of this report are only valid When key geotechnical aspects are inspected by this engineer during construction: • Soil cuts • Foundation subgrade verification • Retaining wall, or rockery placement • Any fill placement • Subsurface drainage installation The proposed new three -unit condominium project at 234 Second Avenue North, Edmonds, is geotechnically viable when constructed in accordance with the recommendations herein, compliance with City of Edmonds approved plans and requirements, and key geotechnical inspection during construction. The plans and specifications for the new Michel Construction, Inc., three -unit condominium project at 234 Second Avenue North, Edmonds, Washington, have been reviewed by this engineer and conform to the recommendations of the analysis and report and, provided that those conditions and recommendations are satisfied during the construction and use, and inspected and verified by this engineer, the area disturbed by construction will be stabilized and remain stable and will not increase the potential for soil movement, and the risk of damage to the proposed development and from the development to adjacent properties from soil instability will be minimal. Michel Construction, 234 Second Avenue North Page nine' CLOSURE: The findings and recommendations of this report were,prepared in accordance with generally accepted professional engineering principles and practice. No other warranty, either express or implied, is made. The conclusions are based on the results of the field exploration and interpolation of subsurface 6onditions. between explored. locations. If conditions are encountered during construction that appear to be different than those described in this report, this engineer should be notified'to observe the situation and review and verify or modify the recommendations. If there are any questions, do not hesitate to call. EXPIRES 12/23/ DMB:vIb Dennis M. Bruce, P.E. Geotechnical / Civil Engineer 001L0 KEPOPT TEOT -HOLEO 50 30 INDICATE5 50IL5 TE5T �HOLE Edmonds. Street 20.00' CB # 1 TYPE 1 RIM: 51 60\ INV: 47 56 G7�5 q IV - m NO CL05E IN CUR13 CUT EXI511�G lIPE atio L6 OUG.H. MAIN EX13 RNO L HOU5E 7'0 5E 9EMOVEO 4 2 5 ;3 NEW 7_�IPL EX cc) 201 M CE55 C) 3'HIGH y k5N 120. 00' 3 UNIT MULTI -FAMILY BLDG. MICHEL CONSTRUCTION, INC. LOCATION: 234 2nd Ave N EDMONDS, WA 98020 E5C3 LL :.996 Dc 3: Lu 16.00, '5AWCUT N1"=20"I 2 Jh d Erosion and Sedimentation Control (ESC) Checklist I Will work entail, Yes No a Grading Permit? X a Clearing Permit? > 500 lineal feet of trench excavation? work in a Critical area? If all answers to 1 are no, ESC plan not required. Otherwise continue below. 2 A) Separate Plan depicting ESC devices B) Limits of disturbed area C) Perimeter control, protection of adjacent areas D) Existing & Proposed Contours E) Location of construction entrance and detail F) Identify Drainage features, streams, wetlands,seeps, swales, etc G) Show cut & fill slopes, indicating top/bottom of slope/catch lines H) Conveyance System 1) Locate drainage pipes, ditches, swales, cut-off trenches 2) Temporary Pipe Inverts, or minimum slope & cover 3) Grades, dimensions, location, flow direction for ditches/swales 4) Bypass details for off -site runoff 5) Locations and outlets for Dewatering systems J) Provide ESC notes 1) Stabilization of exposed areas (verbatim by code) 2) Other measures as needed to limit sediment impacts 3) Inspection & Maintenance of ESC devices & CBs 4) Seeding, mulching, matting requirements 5) Stockpiling location & protection 6) Street sweeping 7) Construction access 8) Vehicle cleaning to prevent tracking 9) Du st Control 10) dtl�e r K) Construction Sequence 1) Preconstruction Meeting 2) Call for Utility Locations 3) Review ESC notes 4) Flag Clearing Limits 5) Installation of ESC devices 6) CB protection 7) Grading Activities 8) Reference stabilization of exposed area requirements 9) Utility Activities 10) Removal of ESC devices only after Stabilization 11) Other L) Other 3 Land disturbing activities greater than 1 acre? Complete Incomplete Comments X X X X Show Existing & Proposed Contours X Not applicable, Not applicable Not applicable Not applicable 1 Not applicable Not applicable Not applicable X X X X X X X X X Not necessary Yes No X E� If all answer is no, end of checklist. Otherwise continue below. Sediment Trapping 1) Sized per DOE or King County SWM manual 2) Berm Width and Slope inside & outside slopes 3) Storage info., depth, length, width 4) Conveyance to Trapping Facility 5) Typical Section View 6) Typ. details of gravel cone, standpipe, filtering devices 7) Detail control/restrictor device location & details 8) Mulch and/or cover of berms and slopes 9) Rock check dams, spacing, sections 10) Stabilization techniques 11) Other Not necessary Site is stabilized Comments ou CA FILE NO. 'q Atical Areas Checklist* -------------------------------------------------------------- Site Information (soil s/topography/hydrology/ve getation) 1. Site Address/Location: . cP-,3 41 j5P '% 6( 1�v c— 41- 2. Property Tax Account Number:— jqq21_ 0or _00,7 0,0 3. Approximate Site Size (acres or square feet): 4. Is this site currently developed? yes;_no. If yes; how is site developed? FIC" 5. Describe the general site topography. Check all that apply. Flat: less than 5-feet elevation change over entire'site. Rolling: slopes on site generally less than 15% (a vertical rise of 1 0-feet over a horizontal distance of 66-feet). Hilly: slopes present on site of more than 15% and less than 30% ( a vertical rise of I 0-feet over a horizontal distance of 33 to 66-feet). Steep: grades of greater than 3 0% present on site (a vertical rise of I 0-feet over a horizontal distance of less than 33-feet). Other (please describe): 6. Site contains areas of year-round standing water: /Vo Approx. Depth: 7. Site contains areas of seasonal standing water: Approx. Depth: What season(s) of the year? 8. Site is in the floodway M0 floodplain of a water course. 9. Site contains a creek or an area where water flows across the grounds surface? Flows are year- round? - /Vo — Flows are seasonal? - (What time of year? 10. Site is primarily: forested ; meadow ;shrubs mixed urban landscaped (lawn,shrubs etc), 11. Obvious wetland is present on site: A/0 ... ... ... ... .... . t on d oil �4pk- A ---VN0 V nd'.'i p­ �6 t nt,on,s .ypf a..e f�ic ti: t -rft�o­..41. y oi., A."pip '�ges i i� .4 ij: A.rias:" Yentor sit+. it in% es+Zrip;�.. d hAza 4 W. e w M 'd "d e arth �ubsided6c: andsli e rd: + i? ally.t. p�4�yt - ig 40 '=_Ch1LdK PW IWOM 0 City of Edmonds Critical Areas File IJA� Critical Areas Checiffst Fee: $45.00 Date Received by Dev. Serv..Dept�a �i(D �-� City Receipt No:-- LS(o2'7, Date Mailed to Applicant: CRITICAL AREAS CHECK LIST The Critical Areas Checklist contained on this form is to be filled out by any person preparing a Development Permit Application for the City of Edmonds prior to his/her submittal. of a development permit to the City. The purpose of the Checklist is to enable City staff to determine whether any potential Critical.Areas are. or may be, present on the subject property. The . information needed to complete the Checklist should be easily available from observations of the site or data available at City Hall (Critical Areas inventories, maps, or soil surveys). An applicant, or his/her representative, must fill out the checklist, sign and date it, and submit it to the City. The City will review the checklist, make a precursory site visit, and make a deterrnination of the subsequent steps necessary to complete a develo'pment permit application. Please submit a vicinity map along with the signed copy of this form to assist City staff in finding and locating the specific piece of property described on this form. In addition, the applicant shall include other pertinent infor mation (e.g... site plan, topography map, etc.) or studies in conjunction with this Checklist to assist staff in completing their preliminary assessment of the site I have completed the attached Critical Areas Checklist and attest that the answers provided are factual, to the best of my knowledge (fill out the appropriate column below). Owner/Applicant: 49kI / / " C' 1 e K7 4-f �- Name -7,�o 7 Street Address city State Zip - )76 Telephone Signature ,�)' Date Applicant Representative: Name Street Address City State Telephone Signature Date Zip czecepdon�anakacl.doc (over) DA Zone C N.E. 1/4, SEC. 23 T27N.9 R.3 E.W.M. 252 731 '728 . 73D 71 P. 0, PER 62 20 4 r.5r. 9 16 j 3-3. 132 10 623 6)4 NO 6/1 zz 611 08 607 too . .1. 00 to) 602 605 40 SCALF IN, F64ET 96 10 613 5-47 tn 90 31 602 SNRR 5 05 5,4 1 :: 50 A. 610 53 6 721. 0 C4 ap 9 2 709� 9 puarr 5OUND cz& 31 z u /us. 4 5/0 :, ; 4— os SOUND VIEW -60) L4 61,q 4 > Iq 11 PTS. AIS 0, Ail D11 ILE 07 432 U a CIE 41( 420 4 3,j In t4 76 NO \9 -,DA-LEY 0 civic >/ vo SPRAGUE 9/ "Fie, 0 5T rwy .9 cpv ip Ap< ry CL GAAND STAN 1 4-300 00, 4;p /cb -E R7 118 A 19A UK MAIN j12 f4 LCT -? PARA? 01 14F I,. I Ln CENT-" com') Aq 0 7 cm Ln Ln DA ST. OLD qu WASTE U0 nj 203 tv MILL ej IN Ic 261 209 TOWN CIF fm I Ito pi4,qv r Lqmcaoi 21C 3 16 to I� 222 2' 228 ril- 3 224 2 IN, 1 224 �22 53 �2-5? 229 MAPLE Edmonds Street b tion Too (S dftp) a, dt to I I '111.—F e deanau7l (r duo) 4_j ech 3OU PIWID 0 L2r Ir CITY OF EDMONDS SIDE SEWER AS -BUILT ADDRESS 234-2ncl Ave N, PERMIT NUMBER 9404 HOMEOWNER CONTRACTOR MicheLL Construction DATE 4-11-2001 DRAWN I Jim Roberts BY 7777-77-77,77 ,1,7 C. I S 9�, 0.� PERMIT NO: 9404 City of Edmonds PERMIT EXPIRES_�2 SIDE SEWER PERMIT . : -/_ 7 - I AAltirave f%,rrf%netnu-t;f%n- rjjj4_ 1�-C_COWD 6PAAONZ51,11) 4 Property Tax Account Parcel No. 001+ 'a4+005 00-7 25) Attach copies of all access and utility easements 17,44 Verified and Approved b Owner and/or Contractor: Contractor License 14 �4 a C,-r 0 C., ID 5:7�j Building Permit#: er,� El' -Single Family VMulti-Family (No. of Units 1,7 Fj Commercial (No. of Units F] Public A�L, le"e Invasion into City *Right -of Way: El Yes VNo *RW Construction Permit Cross other "Private Property: El Yes No "Attach legal, description and copy of recorded easement. Owner or contractor signature and acknowledgement statement: By signing for this permit I certify that I have read the City's public handout entitled Oide Sewer Specificatio . ns, and shall comply with all City requirements outlined therein. ,q Xpq Ll Date ,It" 2 CALL DIAL -A -DIG (1-800-43,,r.-5555) BEFORE ANY EXCAVATION 9 W FOR INSPECTION C L 425-771-0220 extension 320-V 132�kv 24 HOUR NOTICE REQUIRED FOR ALL INSPECTION REOUESTS ......... .............. FOR OFFICE USE ONLY Permit Fee $ _j Repair Fee $_AJIA Issued By: Trunk Charge $ Date Issued: Receipt No: Assessment Fee $ 2" City Permit Surcharge Fee $5.00 Total Fees Paid $ zo NOTE: IF JOB SITE IS NOT READY FOR INSPECTION WHEN INSPECTOR ARRIVES A $45;RE-INSPECTION FEE WILL BE CHARGED., Job Site Ready YES NO Date: Initial: Partial Inspection: Date: Initial: Pa rtial Inspection: ---Date: Initial: I FINAL INSPECTION APPROVED: Date: Initial: As -built to Street File: 1,� PERMIT MUST B E POSTED ON JOB SITE 1� White Copy: File Green Copy: Inspector Buff Copy: Applicant L;temp;bldgform�;sspermitjlk4/00 130 z C"4 IN5TALL I I NEW :�;j C[3 Lu LU OG) C) INTER5ECTION OF PKIVEWA�j & CENTERLINE OF KIGHT-OF- Edm WAY I onds Street IEXI511�G qII)E --patio- 3'HIGH . . .. . .. . . . . .. . . .. . . EX15TIN c- HOU5E rO 1100, 5E REMOVEO 2 X +00 IN I L6 NEW �\IZIPLEX 92.50 F7 C�l 20:1 MAX HANDICAP ACCE55 Q -W �LK AL (3) 0 + + arms =�� poll 3 1 HIGH 120.00, -ZOCKEPY 6FT CEI)AP FENCED ENCL05UP, EXISTING CONDOMINIUM I �= ZI < DRAINAGE. DATUM KIM -[3#3 50.20' PARKIN APPROVED BY PLANNING 6. -& PLOT PLAN M/1-0/cc) N Lu < cf) 5;� In Lu < RECIEIVED DEC 14 2000 DEVELOPMENT SERVICES CTR. CITY OF EDMONDS HEIGHT CALCULATION5 A 52.bb' 5 56.21' Al c 6.60, 1p 54.51'= AVERAGE GKAPE EX15TING TOFO ri?npnc�m -rnpn VIA . 1 6 EDMONDS ST CITY OF EDMONDS WATERLINE AS -BUILT ADDRESS: PERMIT Q), 234 2ND AVE N NO. XXXXXXXX CONTRACTOR: HOMEOWNERi SCALE1 xxxxxx xxxxx NTS DATE INSPECTED: INSPECTED BY1 DATE DRAWN: DRAWN BY: 00-00-00 1 xx 1 06-29-07 J. TRIEU ,V Ap- Z � e-1 RETURN ADDRESS: City of Edmonds, City Clerk 1215 1h Avenue North Edmonds, WA 98020 CONFORMED COPY 200103130471 03/13/2001 11:48 AM Snohomish P.0002 RECORDED Count' y DECLARATION OF RESTRICTIVE COVENANT MUTI-FAMILY RESIDENTIAL Reference #: Grantor: MICHEL QONSYRUCTION. I -NC Grantee: City of Edmonds Legal Description (abbreviated): Sec_2!2!�3 Twn(� ?W Rng Qt OR Lot_ Block -P Plat )�-IY47 6^1� Assessor's Tax Parcel ID#(s): (1) (2) Assessor's Tax Parcel ID# not yet assigned WHEREAS, MICHEL CONSTRUCTI_ON. INC. is the owner of the following described real estate in the City of Edmonds, to wit: Property Address:jy Legal , - 4-67- Description.--,- 4,0C:,.k Y 0 -F I /—C Dlozo� i '4-yOL7- 6 t--' j,Ae 116Z_ 4,,otf 6- / fl.-r PZ—J�V (X/ 044 /Xy AUTHORIZED FOR RECORDING City of Edmoin Slo By: Date Page—o WHEREAS, the above named owner is desirous of imposing a restrictive covenant upon said premises in compliance with Section 19.00.040 of the Edmonds Community Development Code. WITNESSETH, that for and in consideration of the premises, the above named owner does hereby declare and grant to the City of Edmonds as Grantee the following restrictive covenant, to -wit: That at the time of the execution of this Covenant the Grantors have agreed to the ordinance of the City of Edmonds provide that no building for multiple family housing may be erected on subject property containing more than___.�__units. Said Covenant'shall be binding upon all present and future owners of said real estate and their heirs, successors and assigns. T,- 1/0 , le DATED this--cl _eday of 2000 1'r GRANTOR State of Washington ) .)Ss County of I certify that I know or have satisfactory evidence that��� �W t�ql 6 14 6 L signed this instrument, c=t ' ated that he/she was authorized to execute the instrument and acknowledged it as the ' i f) F_ LXT (title) of M I r /I L (ftjA)ST,1101�_ Z; Q (name of party on behalf on whom instrument was executed) to be the free and voluntary act of such party for the uses and purposes mentions in this instrument. Subscribed and sworn to before me this ::2 10 day of L.�J- Ugg, 6&tL , 20 0 14-.*.%% It Ile Notary Public in and for the StaW of Washingtojf 4t My.commission expires Op WAV. AUTHORIZED FOR RECORDING ,��ity of Ed ds M07 /of 13 y: LV Dat �- 5 Page of 01 Chrisman, Lyle To: Rob Subject: RE: DDCVA - Glen Street - Permit #200980 Rob, I will have an answer for you tomorrow. On the grinder pump issue we discussed this morning. I talked with Jim Waite and the poly pipe is what they use on grinder systems they maintain. Jim said there is more flexibility with poly where the other pipes are rigid and are more prone to breaking. Since this is a private system to the property line unless you want to follow what Public Works uses, you will need to follow the UPC. ------------- — With regard to a staging area on Edmonds street for your project 4t 234 2nd Ave N,, Oart of the parking area on Edmoi St may be used for such purposes. The fencing must not extend be stall width (8.5') nor is it to extend into the intersection. Once you have erected the fence�,,please call the in ection line so we can look at it and make adjustments as necessary. ----Original Message ---- From: Rob [SMTP:rwmichel@nwlink.com] Sent: Tuesday, May 22, 2001 7:53 AM To: Lyle Chrisman Subject: DDCVA - Glen Street - Permit #200980 Hi Lyle: Is a response to my letter of May 11, 2001 forthcoming? Please respond today with a target date. Thank you. Rob /4e co 0 CY) Edmonds Street 0 57A- 1 —W, r/ I �h , RECEIVED ..... is ... .............. lqml- "90- AW& JAN P ?001 090AER - [V( (ORTAT E U uUnues k S FOPA ......................................... * A coordinated utility environment which maximizesjoint utility opportunities to provide quality servicefor the citizens ofEdmonds .............................................................................................................................................................. YOU WILL BE GIVEN A CONFIRMATION NUMBER BY EACH UTILITY ONCE YOU HAVE INFORMED THEM OF YOUR PROJECT. 9TIAN15S.- j?-9-k SD &E- 9, (JAI 1-r InA))-,r-) --k its,-rr)f I'll . ........... . # 000f�;;7-0,nno Rich Afdem — 425-670-3208 You will need to provide PUD with a site plan and a completed New Service Questionnaire. PUGET SOUND FEB 2 L 01 ENERGY Doug Usitalo — 425-356-7520 DEVELOPMENT ', i-�-G GTR. CITY OF Eb. )NDS Or New Customer Construction Department %1-7 2 Z - 1-888-321-7779 VERIZON NW Frol -2)[3 5S Greg Meilsen — 425-710-4120 You will need to provide Verizon with the location of your project, total line requirement, and the date in which service is required. AT&T BROADBAND 1# Esa Patterson — 425-263-5317 SE E nph - 769 You will need to provide OVWSD with the surve our site and or cu Myrnpic View Servi ea complete a development information form. THIS FORM MUST BE COMPL ' ETED AND GIVEN TO DEVELOPMENT SERVICES STAFF AT THE TIME OF PERMIT SUBMITTAL �w 0 0 CITY OF EDMONDS 2!)() - 51H AVE N - EDMONDS, "A 98020 # (206) 771-3202 COMMUNITY SERVICES: Public Works e Plani iing e Parks and Recreation 9 Engineering 8 9 0 . 1 94 - April 4, 1991 Shirley Hobbs 234 - 2nd Ave. N. Edmonds, WA 98020 LARRYS. NAUGHTEN MAYOR CERTIFIED MAIL TP FILE RE: Problems with venting of your plumbing fixtures Dear Resident: The City's sewer cleaning records show that the home at experiencing problems with the venting of some of your when the City crew is conducting cleaning operations of the in front of this address. PUER E. HAHN DIRECTOR this address is plumbing fixtures City sewer line The City's cleaning operation is essential for both you and your neighbors. It cleans ' debris in lines to prevent plugs, prevents corrosion and potential future collapse, and achieves a better flow characteristic in the public sewer lines. We need to do this often -- perhaps even 3 times a year -- in some critical areas. The City's cleaning operation typically involves the utilization of a high pressure water jet. The problem which occurs at the home is the result of a high pressure surge through your internal plumbing system. A properly constructed plumbing system is designed to easily vent this additional pressure without any visible impact at your residence. An undersized venting pipe (or not having enough vents) cannot handle the pressure surge, and the only release that's available is then through your toilet (or another fixture). The Uniform Plumbing Code typically requires a 211 vent, and further requires a separate vent for each plumbing fixture which is connected to the sewer (a toilet, a sink, a shower). Your home clearly does not have an adequate venting system (you either have a 1-1/4" vent, or not enough of them), and you therefore may continue to experience the pressure surges. The City does not have a choice as far as discharging its responsibility in cleaning the public sewer line. It is therefore up to you to take corrective measures as to how to properly vent your own plumbing system. The City has come up with two options that will remedy your problem: Option 1: Upgrade stack vents for toilets and other fixtures which are experiencing problems to required sizes. 0 � �'t'! i� j Page 2 Option 2: Install a clean -out outside of house per attached specifications. Enclose box so it can vent properly when excess pressure is put on house lines. This option would be the cheapest and simplest way of correcting this problem. At the same time, it would allow access to sanitary sewer lines if stoppage should occur. This vent clean -out would allow a place for backup in lines to go before entering your house and causing costly damage. The City would appreciate your expeditious cooperation in this matter. The City must continue proper maintenance of its sewer lines, but we obviously do not wish to see continued problems occurring on your property because of poorly designed vents. It is your responsibility to correct these deficiencies. We cannot keep notifying you each time we come out to clean the line. It's up to you to have a plumbing system that conforms to code. Option 2 is a relatively simple one to construct. Should you have any questions on these options, please call Everett Akau, Scott Highland or myself at 771-3202, extension 317 or 318. Sincerely, Ron Holland Water/Sewer Supervisor Enclosure SEWERVEN/TXTSEWER 0 0 -4 -AIV I -�r-2A C4 i n, —.1-1 -- -, V v <�j -riV -a IJA . �7/�,- )� ( I ) --W�'�' id -aZ� -J!�- )%-"3,. 17/1 I b /a -., /q I t7 jr-ol f-7 -">,A,4 -)A41_j J -;P A,.,4 -. V WIAQ . 1 4 INITIATOR: Name Mrs. Hobbs Phone 774-3964 home Address 234 2d- No. .345�-4572 work - ACTION: 1. Rec'd call 'from Mrs. Hobbs re,the larjZe Winnebago recreatiotL vehicles parking on the 6treet (owners live.at ihe apt. hn1jAA at 3d K RAMOVAQ Street The vehicles Block the view of her backing out of the d/w. it sound.s like the vehicles park,there all the.time and may bp- in uInlat-4nn -f tba t-r .qff4 -C ordinance. Pleasae inizestigate and let her know if there is anything that 'can be done. 7 Am".007d 1. M 2 M. r4 WJ T,,j T-A KG IR - - iA AgON Ww". �= W All concerned notified Action Completed d OA pr e—yriim "I ib Map APPLICATION for The City of Edmonds SEDE SEWER PERYaT EASEMENT No . .......................................... NEW CONSTRUCTION E] REPAIRS 0 113-02 00 OWNER.......... G....L....Smi.th ....................................................................... CONTRACTOR ................................................. ........... .................................... PERMIT No . ............. ADDRESS ...... ?.14 ... 2nd --- Ave ...... N ............................................................... LEGAL DESCRIPTION: LOT No . .............................................. BLOCK No . ............................................ ... ....... ..... .. . .. - 0 Ll NAMEOF ADDITION ................................................................................................................... ..................... Dye Tested On Sewer 1972 Approved: DATE................................................ By ...................................................................... 1;' 0 015 7 jo 30 CB #3 -TYPE 2 RIM: 52.50 INV: 4 .99 (5� r'41 CB #1 TYPE 1 RIM: 51.66 INV: 47.58 EXISTING r10 - 4 A - .1 __ � I �L_j 1r'--% RIM: 50.20 INV: 47.00 S I P" I X �Iz Edmonds Street 20.00' REMOVE AND REPLACE EX15TING CUR[3/GUTTER CL05E IN EX15TING 3" PRAIN TO 13E CAFFEL) /(NOT CATCHING ANY WATER) ol ACCE55 Lnk,EXI511�G JIDE 1W LK 7— T, 'q" LD 0 op�.-. _v to /1 OUGH PRAIN\,�\ E -INO X15 7 13E 9EMOVEP HOUOE TO "Pi 17 CON N ECT­ PRX�N 5 2 3 GAR\AGE EXIT & POWN5POUT icy) 15 T -KIP A \ I NEW 1 10.00 IRRIGATION TEE W/ BACKIFLOW DEVICE REMOVE AND REPLACE u- ;000 ---CONNECT 6" P\/C 5EWER \A15HFAILT ALLEY AND REORAPE �"00 To T_ TO DRAIN TO THE WE5T Z 5 lix UT -gasEmIgg JT. 7, HIGH � 1\2 10. 0 0' (5N POCKM B CB #4 CB #2 CONTROL 129.9 LN FT 6" PVC @ 4.47% 5AWCUT TYPE I TYPE 2 RIM: 55.413 RIM: 52.62 PROVIDE LOCKING LAMPHOLE < INV: 53.89 INV: 47.80 COVER 0 5EWER CLEANOUT CB #5 LN FT 6" PVC @ 1% TYPE 1 16.00, RIM: 55.36 7ALLEY BYPASS INV. IN @ 47.83 1 V: 53.64 EXISTING CONnOMINIUM EX15-ING TOPO `ROF'O5E1) TOPO 143 �N NOTE: CONTACT THE EI)MONI)5 FU13LIC WORK5 50 THEY CAN DETERMINE THE CONDITION OF THE EX15TING 6" 511)E 5EWER FROM THE MAIN TO THE PROPERTY LINE. IF THE EX15TING LINE 15 IN POOR CONDITION, THE LINE 5HALL 13E REFLACEI) WITH NEW 6" FVC. TOTAL AREA: 7200 SID FT .17 ACRES IMPERVIOUS: 5340 SID FT .12 ACRES DETENTION: 318 CUBIC FEET = 43 LN FT OF 36" N-1 2 PIPE WATER QUALITY: ALL PARKING UNDER BUILDING NO WATER QUALITY MEASURES REQUIRED GRADING: CUT 58 CU YRDS. LEGEND 3v 13UILPING � 10-001 DRIVEWAY EX15TING GRAPE� TROUGH 16.00, DRAIN ALLEY ALLEY EAST/WEST SECTION 1" = 10.00' 1 0 FIN15,H GRA101 CROSS SECTION A -A SCALE: I"= 20'-0" 1 Offil RN15H GfZA 3'p.. rEf, CROSS SECTION B-B S :: 1" 20'-0" "CALL (S) c� Lu C) w :�i M : I C�, Lu 2% 0 DRIVEWAY CENTERLINE PROFILE S SCALE: I" = 20'-0" 0� P0, I f0m -,�Tgdim. Will Vl(& b'2 %wid VMOVe "q PeJS) bik-+ 111�U 0 &0- S'14 t 51w -,b veri-Rj *4k- , DRAINAGE, PARKING, PLOT PLAN RECEIVED JAN 3 0 2001 PERMIT COUNTER I,,- T_ a) (D c: .5)(0 c: "It w LO I—" (0 > 0 LO LO 00 00) a) 03: a) 0 Lij z _j w (M 0 cf) < c\j LO LO Lf) rx uj 0 (j ED uj b :� n' + > LL. ce nr) tn Lu r< j Lu 12/12/200 ::�EVISIONS A\ 1/30/01 GENERAL NOTES 1. All work and materials shall be in accordance with City of Edmonds Standards and Specifications, and Washington State Department of Transportation Standard Specifications for road, bridge and municipal construction. 2. Temporary erosion/sedinlentation control Measures shall be implemented prior to any grading or extensive land clearing. These facilities shall be satisfactorily maintained until construction is completed and the potential for erosion is minimal. 3. All pipe sliall be placed on stable earth, or if in the opinion of tile City Engineer, (lie existing foundation is unsati s factory, then tile Unsuitable material shall be excavated and tile void backfilled with a free draining granular material, free of debris and clay. STORM SYSTEM 4. All grates (inlet and catch basin) shall be depressed 0. 1 foot below pavement grade. All catch basins to be type I unless otherwise noted. Tile contractor shall be responsible for adjusting all Manhole. inlet, and catch basin frames and grates to grade just Prior to Pouring Of curbs and paving. All catch basills with a depth over 5 feet to tile flowline shall be a Type 11 CB. All structures located outside of tile right-of-way shall have locking lids. Catch basin fraine and grate shall be Olympic Foundry part No. SM 50G, Herringbone pattern; part No. SM 52, thru-curb inlet; part No. Sm 44, rolled curb type; or other approved equal: or as otherwise called for on the plans. 5. Storniwater retention/detention facilities must be constructed and maintained in accordance with City of Edmonds requirements. 6. All road fills shall be compacted to a minimum of 95010 of maximum density when tested using the modified Proctor test. Compaction shall be accomplished in accordance with Section 2-03.3(l 4)C, Method B or C. 7. If cut and fill slopes exceed a lllaXil]lLllll Of One foot horizontal to two feet vertical, a rock or concrete retaining wall will be required. 8. Approximate locations of existing utilities have been obtained from available records and are shown for convenience. The contractor shall be responsible for verifying the location of all existing utilities whether shown or not. The contractor shall call the Utility Locator Service, 1-800-424-5555, two working days prior to ally Construction. 9. Tile contractor shall take all necessary precautions for the safety of employees on the project and shall comply with all applicable provisions of Federal. State, and Municipal safety laws and building codes. He sliall erect and properly maintain, at all times, as required by tile conditions and progress of the work. all necessary safeguards for protection of workmen and the public; shall post danger signs warning against known or unusual hazards; and lie shall designate a responsible member of his organization on the construction site whose duty shall be the prevention of accidents. 10. Tile contractor shall be responsible for maintaining and repairing asphalt and gravel Surfaces disturbed as a result Of this Construction until they are accepted by the Public Works Department of the city. CONSTRUCTION SEQUENCE. PRE -CONSTRUCTION MEETING -CONTACT- CITY OF EDMONDS ENGINEERING INSPECTOR DRILLED ORIFICE #2 RIM ELE. 55-82 FGL 1.03" DIAMETER @ELEV. 49.40 12" MIN OVERFLOW <' ELE.: Fro Downspouts Moi-tai- inside and outside OSTORM 611 IPJV ELE PVC DEPJTEPJTION DRAIN 47.80' PIPE BEYOPJD Restrictor IPJV ELE: 47.50 W/ drilled orifice .66 in dia. 1.00, MIN. ELEV: 45.00 EXISTING CEI #A RIM: 50.20 INV: 47. BO - 425-771-0220, 2. CALL FOR UTILITY LOCATIONS 3. REVIEW ESC NOTES AND DETAILS 4. INSTALLATION OF ESC DEVICES. 5. INSTALL CB PROCTECTION. 6. GRADING ACTIVITIES 7. REFERENCE STABILIZATION OF EXPOSED AREA REQUIREMENTS S. UTILITY ACTIVITIES 9. CONSTRUCTION ACTIVITIES In 121:NAnX/,&l nl: FOr nFX/IrlPq A J, 1, lul W wi: '4') A 1111 11 M I CEI #1 TYPE 11 RIM: 51.66' INV: 47.58'\ N.S. C13 #2 CONTROL TYPE 2 RIM: 52.62' INV: 47. 80' CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 C13 #3 TYPE 2 RIM: 52.50' INV: 47.991 - --------------------- --- -------------- -------------------------------- -------------------------------------------------------- --- -------------- ------ - ----------------------------------------------------------------- .................... - . - . - I - . - . - -------------------------------------------------- ----------------------- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -ramm7m-ru -------------------------------------------------- ----------------------------- ------------ ------------------------------ - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ----------- ---- --------- --- --- ------------------------------------------------------------------ -------------------- ........ - ------------------------------------- ------------- ------------------------- ------ ------------------------------- 0 ------------- -- ---------------------------- --- ---------------------------------------------------------------- -------- ----------------------------- ---------- i E4 - f5- ------- ------------------------ --- ------ 0: -------------- -------- --------- ----- ----------------- * ----------------------------- *---* ----------- ----------------- ---------------- ----------------------------------------------- --------- ----------------- ---------------- ------------------------------------------------------------------------- - --------------------- 45 ........ - ----------------------------------- --------------------- ......... I ....................... I ............. ................. ------ — ------------------------------ -R ---------- ----------------------------------- 1---1 ------------- * --------------------- -------- ------------------------- -------- - SIDESEVVE ----------------------------------------------------------- --------- ...... ----------------------------------------------------------------------------------- 40 1-4f-L-N-FT-F--FVC--@-1% ---------------------------------------------------------------------------------------------- ...... ----------- ----------------- ------ ---- ............. ----------------------- ---------------------------------------------------------------------------------------------------------------------------------------- ----------------- -- ----------------------------------------------------- ...... ......... ...... ------------------------------------------------------------- --------------------- ----------- ----------------------------------------------------------- ...... --------------------------------------- -- --------------- I APPROVED FOR CONSTRUCTION: 11. INSTALLATION OF LANDSCAPING CITY ENGINEER 2 -// 0114 �: � / DATE o C\j ONrf- 17 - W > 0 C\j CO (D Ld z -j W rr' 0 r Cf) C\l 0 to U') to -X LJ 0 b ED b �D z C 'z Z U Z Z r) �j LU z z -j LU 30 30 STANDARD STREN FILTER FABRIC NOTE: ONLY TO 13E U5EI) WHERE FONPING OF WATER A13OVE THE CATCH DA51N WILL NOT CAU5E TRAFFIC FRODLEM5 AND WHERE OVERFLOW WILL NOT RE5ULT IN ER05ION OF 5LOFE5. A -A FILTER FA[3R1C FROTECTION N.5. FILTER FADRIC� ��/ 2X2 PF OR 13ETTER 7/5" WASHED GRAVEL IM-1 '56.. LIJ — — — — --- 4 — — — 7- 13URY FILTER FA[5RIC f3OTTOM OF FILTER IN GRAVEL -LINED TRENCH FADRIC IN TRENCH FILTER FEWCE DETAIL NO SCALE 2X2 PF Al 4'- 0" OR 13ETTEP FILTER FA13RIC 2" - 4" TOP OF 5WALE QUARRY 5FALL� ROCK CHECK DAM SECT101 NO SCALE -IS 10, 0S, 0, C,k� 0, OP 4-//4/ P, c 0 0 �;, ;� Q-ss R=25' MIN. 12" MIN. 4" - 8" QUARRY 5FAL5 FROVIDE FULL WIPTH OF INGRE55/ EGRE55 AREA EXISTING 138 #A RIM: 50.20 INV: 47.00 S 12" :2 1LU TENIPORIARY BOAD EUTRAWICE DETAIL :Z W TEMPORARY EROS ION/SED I ME NTATION CONTROL NOTES 1. Maintain natural vegetation for silt control where possible. < 2. Temporary erosion sedimentation control facilities shall be constructed by placing siltation control filters around swales (natural or manmade) and shall be maintained in a satisfactory condition until such time that land clearing and/or construction of permanent drainage facilities are completed and operational. Facilities shall then be removed and the site restored to the original or final design condition. 3. As construction progresses and expected seasonal conditions dictate, more siltation control facilities may be required to insure complete siltation control of this property. Therefore, during the course of construction, it shall be the obligation of the contractor to address any nevv conditions that may be created by his activities and to provide additional facilities, as may be needed. 4. ESC Minimum Requirement - Stablization of Exposed Areas. All soils exposed by land disturbing activities shall be staliblized by suitable application of EIMPs, including, but not limited to, sod hydroseeding, or other vegetation, plasitic covering, or mulching. All BMPs shall be selected, designed and maintained in accordance with the Manual. The exposed soils shall be stabilized according to an approved timetalbe. (Typically, no soils shall remain exposed for more than two (2) days from October 1 through April 30 and no more than seven (7) days from May 1 through September 30) Cover stockpile material with 6 mil vapor barrior. 5. Construction Access Route. Construction vehicle access shall be, whenever practicle, liMitE!d to one route. Access points shall be stabilized with quarry spalls or cruched rock to minimize the tracking of sediment onto public roads. If sediment is transported onto a road surface, the ro;3ds shall be cleaned thoroughly at the end of each day. Sediment shall be removed from roads by !3hoveling or sweeping and transported to a controlled sediment desposal area within 24 hours. Street washing shall be allowed only after sediment is removed in this manner. 6. ESC Minimum Requirement - Manintenance. All erosion and sediment control BrVlPs shall 1:)e regularly inspected and maintained by th owner to ensure continued performance of their intended function. All maintenance and repair sahll be conducted in accordance with the manual. 7. ESC Minimum Requirement - Cut and Fill Slopes. Cut and fill slopes shall be designed and (,onstructed in a manner that will minimize erosion. In addition, slopes shall be stabilized in accordance with ESC Requirement No. 2. S. ESC Minimum Requirement - Storm Drain Inlet Protection. All storm drain inlets made oper-able during construction shall be protected so that storm water runoff shall not enter the conveyance system without first being filtered or otherwise treated to remove sediment 9. ESC Minimum Requirement - Protection of Adjacent Properties. Adjacent properties shal be protected from sediment deposition by appropriate use of vegetative buffer strips, sediment barriers or filte mulching, or by a combination of these measures and other appropriate EIMPs. 10. Remove ESC devices after stablization. APPROVED FOR CONSTRUCTION: CITY ENGINEER 2- , � 49/ DATE 9- EXPIRES 1=1 TEMPORARY Edmonds Street ROCK ENTRANCE EX15JING fVEHICLE CLEANING TO FREVENT TRACKING" AREA EX137-INO HOU5E 7-0 DEKEMOV b2.50' NEW 7-91PL EX 92.50 FT FILTER FENCE .......... ...... 120.00' IBM mes I 77- (D (D C: Lo UJ (D 0 C111 c- LO C-) LO 00 C) (D 0 ui Z —J W rr 0 r U) N 0 1120 LO LO LO -X W 0 (j co cfj b 7� n' FILTER FENCE (3 Z -7 Z LEGENO N Z CU >(D SCALE: 1.00" 20.00' Ui Z Z tn LU Z Z -J UJ 12/12/200 ::IEVISIONS 1/30/01 150 30 C13 #3 -TYPE 2 RIM: 52.50 INV: 4 .99 C13 #1 TYPE 1 RIM: 51.66 INV: 47.58 r- EXISTING CE1 #A RIM: 50.2,1 INV: 47.00 S 1 0 20.00' -to- Edmonds Street REMOVE AND REFLACE EX15TING CURD/GLITTER CLO5E IN TOTAL AREA: 7200 SOFT .17 ACRES IMPERVIOUS: 5340 SOFT .12 ACRES DETENTION: 318 CUBIC FEET = 43 LN FT OF 36" N-1 2 PIPE WATER QUALITY: ALL PARKING UNDER BUILDING NO WATER QUALITY MEASURES REQUIRED GRADING: CUT 58 CU YRDS. EX15TING 3" PRAIN TO 13E CAFFED (NOT CATCHING ANY WATER) GARAGE EXIT REMOVE AND REFLACE V_ #4 A5HFALT ALLEY AND REGRAPE TO PRAIN TO THE WE5T 5AWCUT" C13 #4 TYPE 1 RIM: 55.48 CEI #5 INV: 53.B9 TYPE 1 RIM: 55.36 APPROVED FOR CONSTRUCTION: ITY ENGINEER 2/ / Ct/p DATE EXI5-_IN(_3 TOFO I N * 11405'0 lot AUS 1-6-kIRE6i lob 13UILL)ING � 10-00' DRIVEWAY EX15TING GARAGE 5LA[3: 54.51' T FRO U G H 16.00, PRAIN ALLEY ALLEY EAST/WEST SECT101M ill = 10.00, w 0 4.0 f. nN15H GRAVi! ''A -A' CROSS SECTIoN SCALE: I" 20'-o" z z 1 .0 FIN151-1 61ZA'Lo' 3 FOCKE0 CROSS SECTION- B-B S c CALE: 1*'= 20'4' q) _j Q, U :�: V-- LLJ 0 Lu :2 m .11 0 DRIVEWAY CENTERLINE PROFILE SCALE: I" = 20'-0" DRAINAGE, PARKING, PLOT PLAN RECEIVED JAN 3 0 2001 PERMIT COUNTER otummmoa, M, (D C\j a) m .c: C6 0)"t C Lo w o cz c- Lo C-) Lo .E,� -c- co 0 a) 0 Ld z _j w cr 0 r cf) c\1 0 Lo Lo Lo rx w 0 d c� 0 :2 L z z z tu > LL ('n Z rn Z Lu z z m u_j 2/12/200 EVISIONS \ 1/30/01 GENERAL NOTES 1. All work and materials shall be in accordance with City of Ednionds Standards and Specifications, and Washington State Department of Transportation Standard Specifications for road, bridge and municipal construction. 2. Temporary erosion/sedinlentation control meaSUres shall be implemented prior to any grading or extensive land clearing. These facilities shall be satisfactorily maintained until construction is completed and the potential for erosion is minimal. 3. All pipe shall be placed oil stable earth, or if in the opinion of the City Engineer, the existing foundation is unsatisfactory, then tile unsuitable material shall be excavated and tile void backfilled with a free draining granular material, free of debris and clay. STORM SYSTEM 4. All grates (inlet and catch basin) shall be depressed 0. 1 foot below pavement grade. All catch basins to be type I unless otherwise noted. The contractor shall be responsible for adjusting all manhole, inlet, and catch basin frames and grates to grade just Prior to P0111-ing Of curbs and paving. All catch basins with a depth over 5 feet to the flowline shall be a Type 11 CB. All structures located outside of tile right-of-way shall have locking lids. Catch basin fraine and grate shall be Olympic Foundry part No. SM 50G, Herringbone pattern: part No. SM 52. thru-curb inlet; part No. Sm 44, rolled curb type; or other approved equal; or as otherwise called for oil the plans. 5. Stormwater retention/detention facilities must be constructed and maintained in accordance with City of Edmonds requirements. 6. All road fills shall be compacted to a nlininlUln Of 950/0 Of lllaXillILI111 density when tested using tile modified Proctor test. Compaction shall be accomplished in accordance with Section 2-03.3(l 4)C, Method B or C. 7. If Cut and fill slopes exceed a IllaXiII11.1111 Of One foot horizontal to two feet vertical, a rock or concrete retaining wall will be required. 8. Approximate locations Of existing utilities have been obtained from available records and are shown for convenience. The contractor shall be responsible for verifying the location of all existing utilities whether shown or not. The contractor shall call the Utility Locator Service, 1-800-424-5555, two working days prior to any construction. 9. The contractor shall take all necessary precautions for the safety of employees on tile project and shall comply with all applicable provisions of Federal, State, and Municipal safety laws and building codes. He shall erect and properly maintain, at all times, as required by the conditions and progress of the work, all necessary safeguards for protection of workmen and tile public; shall post danger signs warning against known or unusual hazards; and he shall designate a responsible member of his organization on tile Construction site whose duty sliall be the prevention of accidents. 10. The contractor shall be responsible for maintaining and repairing asphalt and gravel Surfaces disturbed as a result of this construction until they are accepted by tile Public Works Department of the city. CONSTRUCTION SEQUENCE PRE -CONSTRUCTION MEETING -CONTACT- CITY OF EDMONDS ENGINEERING INSPECTOR DRILLED ORIFICE #2 1.03" DIAMETER @ELEV. 49.40 --- Moi-tai- hiside and outside iO STORM 611 INV ELE DRAIN 41 PVC 47.80' Restrictor - vv/ drilled orifice .66 in dia. ELEV: 45.00 RIM ELE. 55-62 12" MIN OXIERFLOW ELE.: Fro Downspouts DENTEWTIOW PIPE BEYOND INV ELE: 47.50 N.S. EXISTING C13 #1 C13 #2 CONTROL CEI #A TYPEII TYPE 2 RIM: 50.20 RIM: 51.66' R I M: 5 2.6 2' INV: 47.80\ INV: 47.58'\ /INV: 47.801 - 425-771-0220, 2. CALL FOR UTILITY LOCATIONS, 3. REVIEW ESC NOTES AND DETAILS 4. INSTALLATION OF ESC DEVICES 5. INSTALL CB PROCTECTION 6. GRADING ACTIVITIES 7. REFERENCE STABILIZATION OF EXPOSED AREA REQUIREMENTS S. UTILITY ACTIVITIES 9. CONSTRUCTION ACTIVITIES In RFMC)VAI nr Pqr nrvicipq CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 CEI #3 TYPE 2 RIM: 52.50' INV: 47.99 1 ------------------------------ --------------------------------------------------------------- --- -- -- ------ * -------------------- ----- ------------ -1 -------- ......... - ................. - ----- ....... .................. ------------ ------------------ ------------ --------------------------- ---------------------- ------------ - / - ---------------------------- -------------------------------------------------------------------------------- -------------------------------- ------------------------------- -------- ------ -- -- -------------------------------------------------------------------------------------------------- -------- ------------------------------------- - -- ------- -- -.- ----------------------------------------------------------------- 50 --------- -- - ----- ----------- ---------------------------- --- ---------------------------------------------------------------- 57- ........ - -------------------------------- ------------- ---------------------------------------------------------------- ------------------------ --- --- --- ------- 0: 19- --------------------------------------------------------------- ------ ------ --- ---------------------- -------- ---------------------- ------ ----------------------------------------------------------------- - - --------------------------------------------------------------------------------------- --------- ------------------------------------------------------- $ ----------------------- ---------------------------------------------------------- - SIDE-SEVVE ------- - --------------------------------------------------------------- R ------------------------------------------------------------------- ----------------------------------------------------- -------------------------------------------------------------------------------------------------- ------- * ----------------------- * --------------- * -------------- K5-L-N-FT--&-FVG-&1�X; ------------------------------------------------------------------------- 40 W --------- �6�*�8�8� ---------------------------------------------------------------------------- ----------------------------------------------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------- --------------- --------------------- ----------------------------------------------------- --------------------------------------- --------------------------------------- ------------------------- --------------------------------------------------------- ------------------- --------------------------------------------------------------- ----------------- I APPROVED FOR CONSTRUCTION: 11. INSTALLATION OF LANDSCAPING CITY ENGINEER ZMAW EXPIRES 1 I Ql�'X"", 2111-2111'`1011161-� 1, 7,,,,,, 7-yd a 6 1 C\j C U-) W o---, (.0 c) C\1 C- LO C) L0 00 C-) W Z I W rr 0 r Cf) < C\l .0 Lo Lr) Lo -X W 0 C� 0 2 n" �D Z n 'Z .-j MC) 4--0- (U > LL LU Z LU 12/12/200 ::IEVISIONS 1/30/01 III = 20'- 0" HRIZ III = 10'- 0" VERT RECIEWED JAN 3 0 2001 PERMIT COUNTER 30 30 STANDARD STRENGTHx, GRA FILTER FABRIC x .6. A V , x <X CATCH 13A51N 0 NOTE: ONLY TO 13E U5E1) WHERE FONPING OF WATER A13OVE THE CATCH 13A51N WILL NOT CAU5E TRAFFIC FRODLEM5 ANP WHERE OVERFLOW WILL NOT RE5ULT IN EF,0510N OF 5LOFE5. A -A FILTER FA[3R1G MOTECTION N.5. FILTER FAEW14� 2X2 P F \ ��/ OR DETTER 7/8" WA5HEE) GRAVEL 111W 36.1 LIJ — — — — --- 7- DURY FILTER FADRIC O.C. � Z IN GRAVEL-LINEP TRENCH DUPY DOTTOM OF FILTER FADRIC IN TRENCH FILTER FENCE DETAIL NO 5CALE 2X2 PF 1/ 4- - 0" OR HTTER A FILTER FAMIC Z- - 4" TOF OF 5WALE QUARRY 5FALL5 ------- - ------- ROCK CHECK DAM SECTI01 NO 5CALE R=25' MIN.� 12" MIN. 4" - 5" QUARRY5PAL5 -IS �11 b 1,1C �0 70, S014 5 �"-Ss EXISTING C13 #A RIM: 50.20 INV: 47.00 S 12"\ FROVIDE FULL WIDTH OF INGRE55/ EGRE55 AREA' LU TEMPORARY ROAD EPJ'TRAPJCE DETAIL Z LIJ TEMPORARY EIROSION/SEDIMENTATION CONTROL NOTES Q < 1. Maintain natural vegetation for silt control where possible. -:�� LU < (D M 2. Temporary erosion sedimentation control facilities shall be constructed by placing siltation V-- C,\ control filters around swales (natural or manmade) and shall be maintained in a satisfactory condition until such time that land clearing and/or construction of permanent drainage facilities are completed and operational. Facilities shall then be removed and the site restored to the original or final design condition. 3. As construction progresses and expected seasonal conditions dictate, more siltation control facilities may be required to insure complete siltation control of this property. Therefore, during the course of construction, it shall be the obligation of the contractor to address any new conditions that may be created by his activities and to provide additional facilities, as may be needed. 4. ESC Minimum Requirement - Stablization of Exposed Areas. All soils exposed by land disturbing activities shall be staliblized by suitable application of EIMPs, including, but not limited to, sod hydroseeding, or other vegetation, plasitic covering, or mulching. All EIMPs shall be selected, designed and maintained in accordance with the Manual. The exposed soils shall be stabilized according to an approved timetalbe. (Typically, no soils shall remain exposed for more than two (2) days from October I through April 30 and no more than seven (7) days from May 1 through September 30) Cover stockpile material with 6 mil vapor barrior. 5. Construction Access Route. Construction vehicle access shall be, whenever practicle, liMitE!d to one route. Access points shall be stabilized with quarry spalls or cruched rock to minimize t.he tracking of sediment onto public roads. If sediment is transported onto a road surface, the roiads shall be cleaned thoroughly at the end of each day. Sediment shall be removed from roads by !3hoveling or sweeping and transported to a controlled sediment desposal area within 24 hours. Street washing shall be allowed only after sediment is removed in this manner. 6. ESC Minimum Requirement - Manintenance. All erosion and sediment control BIMPs shall 1:)e regularly inspected and maintained by th owner to ensure continued performance of their intended function. All maintenance and repair sahll be conducted in accordance with the manual. 7. ESC Minimum Requirement - Cut and Fill Slopes. Cut and fill slopes shall be designed and (.onstructed in a manner that will minimize erosion. In addition, slopes shall be stabilized in accordance witli ESC Requirement No. 2. 8. ESC Minimum Requirement - Storm Drain Inlet Protection, All storm drain inlets made operable during construction shall be protected so that storm water runoff shall not enter the conveyance system without first being filtered or otherwise treated to remove sediment 9. ESC Minimum Requirement - Protection of Adjacent Properties. Adjacent properties shal be protected from sediment deposition by appropriate use of vegetative buffer strips, sediment barriers or filte AikRia RR mulching, or by a combination of these measures and other appropriate BMPs. M. 10. Remove ESC devices after stablization. of WAASR ROCK 27-MYRANCE Edmonds Street EX151ING qI1)E W�LK I fVEHICLE CLEANING 'TO FREVENT TRACKING" NZ APPROVED FOR CONSTRUCTION: ; CITY ENGINEER DATE 1451 C-XXVII; EXPIRES 12rM. EX15 PNO HOU5ET01 13E KEMOVtL? 52.50' NEW 7-91PLEX 92.50 FT FILTER FENCE 120.00' 16.00, FILTER FENCE LEGEND N SCALE: 1.0011 = 20.00' EROSION.. CONTROL PLAN RECEIVED JAN 3 0 2001 PERMIT COUNTER P "M t V C\1 a) cy) (D U-) W CD C\1 CZ c- LO C-) LO 00 C) -(D 0 a) 0 Ld Z —J W 01� 0 r U) C\J 0 Ca LO - Lr) 73 Lo X W 0 n > < LL. CR LLJ 2/12/200 EVISIONS � 1/30/01 '501 30 I CB #3 -TYPE 2 RIM: 52.50 INV: 4 .99,,�, CB #1 TYPE 1 RIM: 51.66 1' METER INV: 47.58\ 1 ICU - GA5 --- Lu > 0- < < -3!: EXISTING co CB #A Lo (s) RIM: 50.20 __X Lu INV: 47.00 S 1 V' \ I /N L J 57< LLJ p 9 0 lon L cu co ca i 3'H10H ROCKERY 0 0' Qs\ CB #2 CONTROL \12,0, 129.9 LN FT 6" PVC Ca TYPE 2 r R 52.62 FROVIPE LOCKING LAMFHOLE INV: 47.80 7. COVER 0 5EWER CLEANOUT \7LN FT 6" PVC @ 1 % ALLEY BYPASS INV. IN C@ 47.83 EXISTING CONDOMINUM 20.00, -Do- Edmonds Street_ REMOVE AND REFLACE EX15TING CURD/GUTTER CL05E IN ACCE55 B G IIIE W�LK walkway /TROUGH 1)KAIN\ EX1577NO X HOU5E TO 13E,1ZEMOVEI? 4 �CONNECT DRA�NG,; 2 3 �N[)5C[ & POWN51`01JT!� i 15\ 1 NEW T_K/P 1 00, -IRRIGATION TEE w/ O� BACKFLOW DEVICE --CONNECT 6" FVC 5EWER .... �cl (SN 4.47% NOTE: CONTACT THE EPMONI)5 FUDLIC WORK5 50 THEY CAN DETERMINE THE CONDITION OF THE EX15TING 6" 511)E 5EWER FROM THE MAIN TO THE FROFERTY LINE. IF THE EX15TING LINE 15 IN FOOR CONDITION, THE LINE 5HALL DE REFLACEP WITH NEW 6" FVC, TOTAL AREA: 7200 SID FT .17 ACRES IMPERVIOUS: 5340 SID FT .12 ACRES DETENTION: 318 CUBIC FEET = 43 LN FT OF 36" N-1 2 PIPE WATER QUALITY: ALL PARKING UNDER BUILDING NO WATER QUALITY MEASURES REQUIRED GRADING: CUT 58 CU YRDS. ul 5 EX15TING 5" PRAIN TO 13E CAFFED (NOT CATCHING ANY WATER) 14000 GA AGE EXIT \REMOVE AND REFLACE \A5HFALT ALLEY ANP REORAPE \ T71 PRAIN TO THE WE5T 1�x 5AWCUT\ CB #4 TYPE 1 RIM: 55.48 INV: 53.89 C8 #5 z 0 -TYPE 1 16.00, RIM: 55.36 N APPROVED FOR CONSTRUCTION: CITY ENGINEER EX15--ING TOFO FPOF'0!5E[) TOFO LEGIEWD f �'__ - 21161ol DATE 0 13UILE)ING � 10-00' DRIVEWAY EX15TING GARAGE HAD: 54.511 TROUGH 16.00, PRAIN ALLEY ALLEY EAST/WEST SECT10111d 1" = 10.00' 1 .0 1 .0 rIN15H 6PAIN! CROSS SECTION A -Al SCALE: 1" 20'-0" z 1 .0), rIN15H GVAPI-2 L OCKEK) CROSS SECTION B-B S "CALL: 1" 20'-0" - (j) —1 C*N U Z �- LL1 0 Lu :2 C, Lu Q I _<_ 2% 0 1 DRIVEWAY CENTERLINE PROFILE SCALE: I" = 20'-D" ,DRAINAGE, PARKING, PLOT PLAN RECEIVED JAN 3 0 2001 PERMIT COUNTER A 'gxwv'wv� (3) LLI U-) 1-1-1 (c) 0 c\j M Lo L0 00 C-) Cy) < 0 (1) C) Ld z I w rr 0 3: c/) < c\j Lo Lo Lo X w 0 (j m uj b :5� L �D z z z ci > U. ce Z Z (D Z �E; j Lu 2/12/200 EVISIONS N 1/30/01 al s 1. All work and materials shall be in accorclance with City of Edmonds Standards and Specifications, and Washington State Department of Transportation Standard Specifications for road, bridge and municipal construction. 2. Temporary erosion/sedinientati011 Control Measures shall be implemented prior to any grading or extensive land clearing. These facilities shall be satisfactorily maintained until construction is completed and the potential for erosion is minimal. 3. All pipe shall be placed oil stable earth, or if in the opinion of the City Engineer, the existing foundation is UnSatig factory, then the unsuitable material shall be excavated and the void backfilled with a free draining granular material, free of debris and clay. STORM SYSTEM 4. All grates (inlet and catch basin) shall be depressed 0. 1 foot below pavement grade. All catch basins to be type I unless otherwise noted. The contractor shall be responsible for adjusting all manhole, inlet, and catch basin frames and grates to grade just prior to pouring Of curbs and paving. All catch basins with a depth over 5 feet to the flowline shall be a Type 11 CB. All structures located outside of tile right-of-way shall have locking lids. Catch basin frame and grate shall be Olympic Foundry part No. SM 50G. Herringbone pattern; part No. SM 52, thru-curb inlet; part No. Sni 44, rolled curb type; or 0016- approved equal; or as otherwise called for on the plans. 5. Storniwater retention/cletention facilities must be constructed and maintained in accordance with City of Edmonds requirements. 6. All road fills shall be compacted to a millinli.1111 Of 95% Of IllaXillILlin density when tested using the modified proctor test. Compaction shall be accomplished in accordance with Section 2-03.3(l 4)C, Method B or C. 7. If cut and fill slopes exceed a maximum of one foot horizontal to two feet vertical, a rock or concrete retaining wall will be required. 8. Approximate locations Of existing utilities have been obtained from available records and are shown for convenience. Tile contractor shall be responsible for verifying the location of all existing utilities whether shown or not. The contractor shall call the Utility Locator Service, 1-800-424-5555, two working days prior to any construction. 9. The contractor shall take all necessary precautions for the safety of employees Oil the project and shall comply with all applicable provisions of Federal. State, and Municipal safety laws and building codes. He shall erect and properly maintain, at all times, as required by tile conditions and progress of the work. all necessary safeguards for protection of worknien and the public; shall post danger signs warning against known or unusual hazards; and lie shall designate a responsible member of his organization on tile construction site whose duty shall be the prevention of accidents. 10. The contractor shall be responsible for maintaining and repairing asphalt and gravel surfaces disturbed as a result of this construction until they are accepted by the Public Works Department of tile city. CONSTRUCTION SEQUENCE, PRE -CONSTRUCTION MEETING -CONTACT— CITY OF EDMONDS ENGINEERING INSPECTOR DRILLED ORIFICE #2 1.03" DIAMETER @ELEV. 49.40 --- Mortar itiside arid outside iO STORM 6 " lPJV ELE DRAIN 4 PVC 47.80' EXISTING C13 #A RIM: 50.20 INV: 47. BO 425-771-0220 2. CALL FOR UTILITY LOCATIONS 3. REVIEW ESC NOTES AND DETAILS 4. INSTALLATION OF ESC DEVICES 5. INSTALL CB PROCTECTION 6. GRADING ACTIVITIES 7. REFERENCE STABILIZATION OF EXPOSED AREA REQUIREMENTS S. UTILITY ACTIVITIES 9. CONSTRUCTION ACTIVITIES in ixunx/Ai nr: vicr nPurivc. Restrictor- w/ drilled orifice .66 in dia. ELEV: 45.00 RIM ELE. 55-62 FGL 12" MIN E OVERFLOW ELE.: Fro Downspouts --0 DENTEPJTIOIM PIPE BEYOIUD lPJV ELE: 47.50 1.00'MIN. C13 #1 TYPE 11 RIM: 51.66' 1 INV: 47.58 , N.S. C13 #2 CONTROL TYPE 2 RIM: 52.62' INV: 47. 80' CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 CEI #3 TYPE 2 RIM: 52.50' INV: 47.99V --- ------------------------------ ------------------ -- -- ------ ----------- - ------------------------------------ I -------------------------- 55 ------------------------------------------------- 171-17' " ...... —7-nnrr- —Tr7ilr ---------- ------------------ ------------ ------------------------ ----- ------------------------------------------------------------- — ---------------- -------------------------------- ----------------------------------------- �17 1 7- --- -- ---------------------------- -------------------------------------------------------------------- -------- ----------------------- --------------------------- ----------------------------------- 50 --------- - :_j ......... .. ...................... ..... ... ................................................................ -------- - ------------------------------ ---- ------------------------------------------------------------------ ------- ------------------------ --- --------------------------------------------------------------- ------------------------------------ -------- ---- 4 ----------------------- ---------------------------------------------------------------- a -------- - ----- * ----------------- ---------- --- ----- - --------------------------------------------------------------------- ------------------------- 45 ....... — I ..................... ....... I .............. . . --ml ....... I .................... M -------- ...... ...... M.M. ........ . . . .. . . . . . . . ------------------------------ -- ---------------------------------------------------------- - -------------------------------------------------------------------------- ------------------ ----------------------------------------------- ---------------------------- ------------------------------ ------- ------------------------------------------------------------------------------------------- -W5-L-H-FT-6-FVC--&1% ------------------------------------------------------------------------- ----------- * ----------------------------- * --------- * --------- 40 ---------------------------------------------------------------- W ------ -------------------------------------------------------------------- ---------------------------------------------------------------------------------------------------------------------------------------------------------------- ------------------------- --------------------------------------------------------------- ----------- --- ................. — ----------------------------- ------------------------------------------------------------------------------------------------------------------------- ------------------------------------- ------------------------- ------------------------------------------------------------------------------------------------------------------------------------- 11. INSTALLATION OF LANDSCAPING APPROVED FOR CONSTRUCTION. /)Z�' CITY ENGINEER '2 -// &Ilc:; o / k SYSTEM PROFILE mile a Ti iv, L1, Y�i im I H P""""'40FILE III = 20'- 0" HRIZ III = 10'-0" VERT RECEMED JAN 3 0 2001 PERMIT COUNTER C\1 Q0 ,It Lo W (.0 o C\j LO 0 LO C: co 0 Ld z I W CL: 0 -T C/) C\j 0 Lo LO Lo -X W 0 C5 co b COO > U LU -j Uj 2/12/200 EVISIONS 1/30/01 301 30 STANDARD STREN FILTER FABRIC NOTE: ONLY TO 13E L15EI) WHERE FONPING OF WATER A13OVE THE CATCH DA51N WILL NOT CAL15E TRAFFIC FRO13LEM5 ANP WHERE OVERFLOW WILL NOT RE5ULT IN ER05ION OF 51-OFE5. A -A FILTER FA[3RIC FROTECTION N.5. FILTER FADFIC 2X2 OF \ OF 13ETTER 7/8" WA5HED GRAVEL 1111, 36.. yX-NI! 1 li Ii V� �, 7- BURY FILTER FA13PIC O.C. 1-43LIPY 130TTOM OF FILTER IN GRAVEL-LINEP TRENCH FAL3PIC IN TRENCH FILTER FEWICE DETAIL NO 5CALE 2X2 OF A V 4'- 0" OR 13ETTEP FILTER FA13PIC 2" - 4" UAR 'r TOP, OF 5WALE 0 'y 51'ALL5\', 1, .......... ROCK CHECK DAM SECT10i NO 5GALE R=25' MIN. 12" MIN. 4" - 8" QUARRY5FAL5 FROVIDE FULL WIPTH OF INGRE55/ EGRE55 AREA �0 0" Ct�/41 7-�f S , 6, 014 Q-SS To M-1 TEMPORARY EROSION/SEDIMENTATION CONTROL NOTES ��7 C) EXISTING CE1 #A RIM: 50.20 INV: 47.00 S 12" -7�� Lii LU < 1. Maintain natural vegetation for silt control where possible. >< Ld 0 ZZ 2. Temporary erosion sedimentation control facilities shall be constructed by placing siltation I-- C�, control filters around swales (natural or manmade) and shall be maintained in a satisfactory condition until such time that land clearing and/or construction of permanent drainage facilities are completed and operational. Facilities shall then be removed and the site restored to the original or final design condition. 3. As construction progresses and expected seasonal conditions dictate, more silta�on control facilities may be required to insure complete siltation control of this property. Therelore, during the course of construction, it shall be the obligation of the contractor to address any ne�v conditions that may be created by his activities and to provide additional facilities, as may be needed. 4. ESC Minimum Requirement - Stablization of Exposed Areas. All soils exposed by land disturbing activities shall be staliblized by suitable application of BMPs, including, but not limited to, sod hydroseeding, or other vegetation, plasitic covering, or mulching. All l3MPs shall be selected, designed and maintained in accordance with the Manual. The exposed soils shall be stabilized according to an approved timetalbe. (Typically, no soliis shall remain exposed for more than two (2) days from October I through April 30 and no more than seven (7) days from May 1 through September 30) Cover stockpile material with 6 mil vapor barrior. 5. Construction Access Route. Construction vehicle access shall be, whenever practicle, ]iMitE!d to one route. Access points shall be stabilized with quarry spalls or cruched rock to minimize t. he tracking of sediment onto public roads. If sediment is transported onto a road surface, the ro;Elds shall be cleaned thoroughly at the end of each day. Sediment shall be removed from, roads by !3hoveling or sweeping and transported to a controlled sediment desposal area within 24 hours. Street washing shall be allowed only after sediment is removed in this manner. 6. ESC Minimum Requirement - Manintenance. All erosion and sediment control EIMPs shall I:)e regularly inspected and maintained by th owner to ensure continued performance of their intpnded function. All maintenance and repair sahll be conducted in accordance with the manual. 7. ESC Minimum Requirement - Cut and Fill Slopes. Cut and fill slopes shall be designed and c.onstructed in a manner that will minimize erosion. In addition, slopes shall be stabilized in accordance with ESC Requirement No. 2. 8. ESC Minimum Requirement - Storm Drain Inlet Protection. All storm drain inlets inade operable during construction shall be protected so that storm water runoff shall not enter the conveyance system without first being filtered or otherwise treated to remove sediment 9. ESC Minimum Requirement - Protection of Adjacent Properties. Adjacent properties shal �be protected from sediment deposition by appropriate use of vegetative buffer strips, sediment barriers or filte mulching, or by a combination of these measures and other appropriate EIMPs. 10. Remove ESC devices after stablization. APPROVED FOR CONSTRUCTION: CITY ENGINEER DATE ITEXPIRE 0 to V1. 1W T ?1 wfll�,,-- C-0-10= Edmonds Street SCALE: 1.0011 = 20.00' EROSION CONTROL PLAN. RECEIVED JAN 3 0 2001 PERMIT COUNTER IV mmo,/'u I*,- T— C\J (D Cr) C: I 0) (0 It C: Lo LL1 CD 0 C\I W LO LO co 0 Lli Z -i LL1 rr 0 r U) C\1 0 CO LO LO LO -X Uj 0 (j M C� d :� n I ou 0 Z Z Z OJ > CR Z L.0 J LU 2/12/200 EVISIONS 1/30/01