Loading...
23625 84TH AVE W (2).PDFiiiiiiii lill 11 15973 23601 84TH AVE W Poggemeyer Design Group, Ina 512 6th Street South Suite 202 Phone: (425) 827-5995 Kirkland, WA 98033 Fax: (425) 828-4850 Stormwater Report Edmonds Terrace 236 1h St SW and 84 1h Ave W Edmonds, Washington r_� � December 3, 2001 Project Description The project site is address is 23619 - 23625 84th Avenue West, Edmonds, Washington. The property consists of 1.796 acres for the construction of multi -family housing. The property is panhandle -shaped, with an egress lane to 238th St SW. The main site and parking areas will be graded to or near the existing ground elevation. The panhandle will be graded to provide storm water detention in three 4 foot diameter corrugated steel pipes under the driveway (405 LF total length and a 105-foot long by 6 feet wide biofiltration swale for water quality. Pavement runoff water is directed to the biofiltration swale via storm sewer collection system from paved areas. Existing Site Conditions and Constraints The subject property is relatively flat, sloping approximately 1.0% from north to south. The buildings have been removed from the site. The north portion of the site containing the four buildings does not have sufficient grade drop to install detention and treatment facilities. The biofiltration swale and stormwater detention facilities have been placed in the panhandle portion of the property in order to attain sufficient hydraulic gradient. The geometry of the site constrains what can be done and a hybrid design results for the biofiltration swale due to elevation controls. The elevation of the biofiltration swale is 2.6 feet above the empty level of the pipe storage that has a rise to 4.14 feet of depth for the 100-year storm flows. This swale is close to existing ground level at the south end of the egress to 238th Street SW. In order to protect the properties west of the egress way in the panhandle a concrete weir is shown 7 to protect against the 100-year water level with 15" freeboard. Storms in exce7s!�RCME 7,�Y a D level would discharge as overland flow to the gutter on 238th Street SW. City Coo rdination for Stormwater Facilities BUILDING Dz-PT. Storm Water 12-3-01 Pagel of3 STREET FILE 9 A brief meeting was held at the City of Edmonds with Assistant City Engineer Mr. Don Fiene, P. E. Mr. Fiene provided information for the stormwater analysis as follows: Pre -development pervious surfaces to be taken as nettle or second growth forest. Soil type is Alderwood C. Rainfall intensities are specified in Chapter 18.31) of the Community Code. Best management practices are required for erosion sedimentation control. Silt fence is required for entire site. ,Sitanrgatefsthan oneac-rezequire a temporary sediment pond. ri, QO�-ea), ar(�O�-year storms are to be controlled for the Lake Ballinger water shed. An erosion and sedimentation control checklist was provided. Paved surface runoff is to be treated to water quality standards. Mr. Shields asked if temporary sedi mentation control could be accomplished by constructing the detention storage vault first due to the o'utfall location down the narrow panhandle portion of the property. Mr. Fiene said that this could be considered and a separate control structure would be needed for dead pool storage. Stormwater Facilities Design Detention facilities are required on -site to control stormwater runoff from impervious and pervious areas consisting of access roads, driveways, roofs, and lawns. There are no off - site areas draining onto the site. We propose to use a detention pipe storage system per DOE manual. Hydrologic analysis of the proposed system was performed using Waterworks (SBUH method). Detention storage sizing was based on V2of 2-year predevelopment to 2-year development storm, I 0-year pre -development to 1 0-year development storm and I 00-year pre -development to 1 00-year development stonn. Erosion Sedimentation Control Wet vault sedimentation will be provided in the permanent pipe detention structures. The pipe detention structures will be constructed after silt fence is erected and the rock entrance is completed. A special orifice drainage control structure is shown in the drainage details for holding the dead pool in the permanent pipe detention storage. 0 The dead pool volume was calculated using the runoff volume of the 6-month, 24-hour design storm (64% of the 6-month storm). This volume is 3599 cubic feet. The two - 0 165' long detention pipes will contain 3,239 cubic feet, and the b1ofiltration Swale will contain 0.50 feet depth of storage at level 445.12 or 157 cubic feet. The short fall of 202.5 CF will be attained by increasing the pool depth (raising the orifice) by 0. 10'. Water Quality Water quality will be provided via b1ofiltration Swale. A Swale 105 feet-loRg-by-6-feet width will be prepared and seeded as shown in the drawi-h�g`ST_Ne­w_id_th has been doubled to compensate for less than 200 LF requirement. � Stonn Water 12-3-01 Page 2 of 3 1.0 The Water Quality flow rate was calculated using the runoff volume of the 6-month, 24- hour design storm (64% of the 6-month storm). Best Management Practices Prior to the start of any grading or utility work, temporary erosion and, sedimentation control facilities will be in place. Calculations Calculations are attached. Prepared By: Charles Shields, PE Storm Water 12-3-01 Page 3 of 3 0 F -I A U 'I A 12/3/01 12:2:14 am Shareware Release page 1 Edmonds Terrace 41 Pipe Storage + Wet Bio-Filt. Storage BASIN SUMMARY BASIN ID: 100dev SCS METHODOLOGY TOTAL AREA ....... : RAINFALL TYPE .... : PRECIPITATION .... : TIME INTERVAL .... : NAME: 100 Year Developed 1.80 Acres BASEFLOWS: 0.00 cfs//-", TYPE1A PERV 3.00 inches AREA..: 0.69 Acr 1.10 Acres . r 10.00 min CN .... 86.00,'^ 9 . 0-or-, TC .... 7-4-6-78'0-min 6.30 min ABSTRACTION COEFF: 0.20 TcReach - Sheet L: 215.00 ns:0.1500 p2yr: 1.50 s:0.0050 TcReach - Shallow L: 100.00 ks:27.00 s:0.0200 TcReach - Channel L: 100.00 kc:42.00 s:0.0100 impTcReach - Shallow L: 85.00 ks:27.00 s:0.0100 impTcReach - Shallow L: 107.00 ks:27.00 s:0.0200 impTcReach - Channel L: 190.00 kc:42.00 s:0.0100 PEAK RATE: 0.90 cfs VOL: 0.34 Ac-ft TIME: 510 min BASIN ID: 100pre NAME: 100 Year Predeveloped SCS METHODOLOGY TOTAL AREA ....... : 1.80 Acres BASEFLOWS: 0.00 cfs RAINFALL TYPE .... : TYPE1A PERV PRECIPITATION .... : 3.00 inches AREA..: 1.80 Acres TIME INTERVAL .... : 1,0.00 min CN .... 79.00 TC .... r-72-57786 min ABSTRACTION COEFF: 0.20 TcReach - Sheet L: 60.00 ns:0.4000 p2yr: 1.50 s:0.0286 TcReach - Shallow L: 240.00 ks:5.00 s:0.0250 TcReach - Channel L: 290.00 kc:17.00 s:0.0108 PEAK RATE: 0.36 cfs VOL: 0.17 Ac-ft TIME: 510 min BASIN ID: 10dev SCS METHODOLOGY TOTAL AREA ....... RAINFALL TYPE .... PRECIPITATION .... TIME INTERVAL .... 40 9 40 NAME: 10 Year Developed 1.80 Acres BASEFLOWS: 0.00 cfs TYPE1A PERV 2.00 inches AREA.-.: 0.69 Acres 10.00 min CN .... 86.00 TC .... 46.80 min ABSTRACTION COEFF: 0.20 TcReach - Sheet L: 400.00 ns:0.2.000 p2yr: 1.50 s:0.0140 impTcReach - Channel L: 300.00 kc:17.00 s:0.0060 PEAK RATE: 0.55 cfs VOL: 0.21 Ac-ft TIME: 510 min IMP 0.00 Acres 0.00 0.00 min IMP 1.10 Acres 98.00 6.30 min 12/3/01 12:,2:14 am Shareware Release page 2 Edmonds Terrace 41 Pipe Storage + Wet Bio-Filt. Storage BASIN SUMMARY BASIN ID: 10pre NAME: 10 Year Predeveloped, SCS METHODOLOGY TOTAL AREA ....... 1.80 Acres BASEFLOWs:,x--0.00 cfs / P" RAINFALL TYPE .... TYPE1A e PERV IMP PRECIPITATION .... 2.00 inches AREA..: 1.80 Acres 0.00 Acres TIME INTERVAL .... 10.00 min CN .... 79.00 0.00 TC .... 25.86 min 0.00 min ABSTRACTION COEFF: 0.20 PEAK RATE: 0.10 cfs VOL: 0.07 Ac-ft TIME: 520 min BASIN ID: 2dev. NAME: 2 Year Developed SCS METHODOLOGY TOTAL AREA ....... 1.80 Acres BASEFLOWS: 0.00.c RAINFALL TYPE .... TYPE1A PERV es IMP PRECIPITATION .... 1.50 inches AREA..: 0.69 Acres 1.10 Acres TIME INTERVAL .... 10.00 min CN .... : 86.00 98.00 TC .... : 46.80 min 6.30 min ABSTRACTION COEFF: 0.20 PEAK RATE: 0.38 cfs VOL: 0.14 Ac-ft TIME: 510 min BASIN ID: 2pre NAME: 2 Year Predeveloped SCS METHODOLOGY TOTAL AREA ....... : 1.80 Acre S BASEFLOWS: 0.0,0 cfs RAINFALL TYPE .... : TYPE1A PERV IMP PRECIPITATION .... : 1.50 inches AREA..: 1.80 Acres 0.00 Acres TIME INTERVAL .... : 10.00 min CN .... : 79.00 0.00 TC .... : 25.86 min 0.00 min ABSTRACTION COEFF: 0.20 PEAK RATE: 0.03 cfs VOL: 0.04 Ac-ft TIME: 570 min 12/3/01 12:2:14 am Shareware Release page 3 Edmonds Terrace 41 Pipe Storage + Wet Bio-Filt. Storage HYDROGRAPH SUMMARY PEAK TIME VOLUME HYD RUNOFF OF OF Contrib NUM RATE PEAK HYDRO Area cfs min. cf\AcFt Acres ---------------- 2.4 0 . 570 1608 cf 1.80 2 —31 37D7 510 6166 cf 1.80 -D 3 0.103 S20 3265 cf 1.80 P , -. 4 0.547 510 8957 cf 1.80 5 0.359 5 ,,1.0 7458 cf 1.80 0 C-5 4 0 �rr- 6 0-9.0.0 /510 14806 cf 1.80 tn. %z, 10 0.02P0 1460 2957 cf 1.80 11 <-:-37 580 11300 cf 1.80 12 0.103 910 5461 cf 1.80 () k, t"Olx 12/3/01 12:2:14 am Shareware Release page 4 Edmonds Terrace 41 Pipe Storage + Wet Bio-Filt. Storage STORAGE STRUCTURE LIST STORAGE LIST ID No.. 1 Description: Wet Biofiltrati.on Swale STORAGE LIST ID No. 2 Description: Combined 4001-4-1--.Pipe + Swale UNDERGROUND PIPE ID No. 3 Description: Underground 41 Pipe Diameter: 4-00 ft. Length: 400.00 ft. Slope...: 0.0017 ft/ft upstr: dnstr: Ti A 12/3/01 12:2:14 am Shareware Release page S Edmonds Terrace 41 Pipe Storage + Wet Bio-Filt. Storage STAGE STORAGE TABLE CUSTOM STORAGE ID No. 1 Description: Wet Biofiltration Swale STAGE < ---- STORAGE---- > STAGE < ---- STORAGE---- > STAGE < ---- STORAGE---- > STAGE < ---- STORAGE---- > (ft) --- cf--- --Ac-Ft- (ft) --- Cf --- -- AC -Ft- (ft) --- cf --- -- Ac-Ft- (ft) --- Cf--- --AC-Ft- ........................................................................................................ 445.08 0.0000 0.0000 445.70 368.55 0.0085 446.40 809.55 0.0186 447.10 1251 0.0287 445.10 6.3000 0.0001 445.80 431.55 0.0099 446.50 872.55 0.0200 447.20 1314 0.0302 445.20 53.550 0.0012 445.90 494.55 0.0114 446.60 935.55 0.0215 447.30 1377 0.0316 445.30 116.55 0.0027 446.00 557.55 0.0128 446.70 998.55 0.0229 447.40 1440 0.0330 445.40 179.55 0.0041 446.10 620.55 0.0142 446.80 1062 0.0244 447.50 1503 0.0345 445.50 242.55 0.0056 446.20 683.55 0.0157 446.90 1125 0.0258 445.60 305.55 0.0070 446.30 746.55 0.0171 447.00 1188 0.0273 q 4 (.o - (oZ 12/3/01 12:2:14 am Shareware Release page 6 Edmonds Terrace 41 Pipe Storage + Wet Bio-Filt. Storage STAGE STORAGE TABLE CUSTOM STORAGE ID No. 2 Description: Combined 4001 41 Pipe + Swale STAGE < ---- STORAGE---- > STAGE < ---- STORAGE---- > STAGE < ---- STORAGE---- > STAGE < ---- STORAGE ---- > (ft) --- cf --- -- Ac-Ft- (ft) --- cf --- -- Ac-Ft- (ft) --- Cf --- -- AC -Ft- (ft) --- cf--- --Ac-Ft- �5468 442.48 0.0000 0.0000 443.80 999.30 0.0229 445.20 3200 0.0735 446.60 (� 0.1255 442.60 0.1200 0.0000 444.00 1260 0.0289 445.40 3603 0.0827 446.80 '-N56a800'0.1306 442.80 88.100 0.0020 444.20 1560 0.0358 445.60 4006 0.0920 447.00 5908 0:1356 ZI 443.00 146.82 0.0034 444.40 1861 0.0427 .445.80 4407 0.1012 447.20 6128- 0.1407 443.20 331.39 0.0076 444.60 2168 0.0498 446.00 4808 0.1104 443.40 515.96 0.0118 444.80 2483 0.0570 446.20 5028 0.1154 .11 443.60 738.60 0.0170 445.00 2797 0.0642 446.40 5248 0.1205 I qc!� tz, y r. 4 '4 (- - G Z- 12:2:14 am Shareware Release page 7 Edmonds Terrace 41 Pipe Storage + Wet Bio-Filt. Storage STAGE STORAGE TABLE UNDERGROUND PIPE ID No. 3 Description: Underground 41 Pipe Diameter: 4.00 ft. Length: 400.00 ft. Slope ... : 0.0017 ft/ft upstr: dnstr: STAGE < ---- STORAGE---- > STAGE < ---- STORAGE---- > STAGE < ---- STORAGE---- > STAGE < ---- STORAGE---- > (ft) --- Cf --- -- AC -Ft- (ft) --- cf --- -- Ac-Ft- (ft) --- cf--- --Ac-Ft- (ft) --- Cf --- -- AC-Ft- 442.48 0.0000 0.0000 443.70 851.68 0.0196 445.00 2797 0.0642 446.30 4590 0.1054 442.50 0.0443 0.0000 443.80 982.87 0.0226 445.10 2953 0.0678 446.40 4682 0,1075 442.60 3.8770 0.0001 443.90 1119 0.0257 445.20 3109 0.0714 446.50 4763 0.1093 442.70 17.508 0.0004 444.00 1260 0.0289 445.30 3262 0.0749 446.60 4814_ 0.1105 442.80 44.326 0.0010 444.10 1405 0.0322 445.40 3414 0.0784 446.?0 4814 0.1105 442.90 86.783 0.0020 444.20 1553 0.0356 445.50 3563 0.0618 446.80 4814 0.1105 443.00 146.82 0.0034 444.30 1703 0.0391 445.60 3709 0.0851 446.90 4814 0.1105 443.10 226.03 0.0052 444.40 1856 0.0426 445.70 3852 0.0884 447.00 4814 0.1105 443.20 311.88 0.0072 444.50 2011 0.0462 445.80 3990 0.0916 447.10 4814 0.1105 443.30 398.34 0.0091 444.60 2167 0.0498 445.90 4123 0.0947 447.20 4814 0.1105 443.40 498.25 0.0114 444.70 2324 0.0534 446.00 4251 0.0976 443.50 608.25 0.0140 444.80 2482 0.0570 446.10 4372 0.1004 443.60 726.48 0.0167 444.90 2639 0.0606 446.20 4485 0.1030 12/3/01 12:2:14 am Shareware Release page 8 Edmonds Terrace 41 Pipe Storage + Wet Bio-Filt. Storage DISCHARGE STRUCTURE LIST MULTIPLE ORIFICE ID No. 3 Description: Orifice for 41 Pipe & Swale Outlet Elev: 442.48 Elev: 440.48 ft Orifice Diameter: 0.6250 in. Elev: 446.48 ft Orifice 2 Diameter: 6.0000 in. 12/3/01 12:2:14 am Shareware Release page 9 Edmonds Terrace 41 Pipe Storage + Wet Bio-Filt. Storage STAGE DISCHARGE TABLE MULTIPLE ORIFICE ID No. 3 Description: Orifice for 41 Pipe,& Swale Outlet Elev: 442.48 Elev: 440.48 ft Orifice Diameter: 0.6250 in. Elev: 446.48 ft Orifice 2 Diameter: 6.0000 in. STAGE <--DISCHARGE --- > STAGE <--DISCHARGE --- > STAGE <--DISCHARGE --- > STAGE <--DISCHARGE --- > (ft) --- CfS -- ------- (ft) --- CfS -- ------- (ft) --- CfS -- ------- (ft) --- CfS -- ------- 442.50 0.0015 442.50 0.0015 442.50 0.0015 442.50 0.0015 12/3/01 12:2:16 am Shareware Release page, 10 Edmonds Terrace 41 Pipe Storage + Wet Bio-Filt. Storage LEVEL POOL TABLE SUMMARY MATCH INFLOW -STO- -DIS- <-PEAK-> OUTFLOW STORAGE < -------- DESCRIPTION --------- > (cfs) (cfs) --id-- --id- <�STAGE> id (cfs) VOL (cf) 1/2 2PRE TO 2 DEV .......... 0.02 0.38 2 3 446.11 10 0.02 4931.02 ct 100 PRE TO 100 DEV ........... 0.36 0.90 2 -3 446.62 11 0.38 5485.30 6f 10 PRE TO 10 DEV ............. 0.10 0.55 1�2 3 446.46 12 0.10 5313.17 cf At 19 19 19 AID 19 19 1 19 19 10 49 V V Is 49 V V 39 49 V V I I I V I Edmonds Terrace 52 Units Date: November 25, 2001 By: C. Shields Wet Biofiltration Swale Calculation Criteria: DOE Volume V 2001 BMP T 9.20 Wet Biofiltration Swale 7 Mannings n = 0.032 wetland plants (-* ( Hyd Radius R= area / wetted perimeter (use depth for shallow) i.e. w*d / w+2d l� Velocity Max. = 1 F/S Minimum Length = 100 feet Inflow (pavement runoff) Width (ft) 6 Depth (ft) 0.06 n 0.032 S_ (fuft) 0.0001 2 Year Flow— Fcfs) ­0-bo WQ Flow (cfs) 0.10774 % Impervious 100% Pavement Area (acres) 0.57 WQ outflow 6-Mo. 24 Hr. Channel Flow Calc. Q (cfs) 0.025 V (fts) 0.071 Residence Time for 100 LF (min) 23.6 Inflow 100 Year 100 Year flow (cfs) 0.35 Table 9.1 Table 9.1 Width compensation for 100' provided vs. 200' recommended lengt 0.72" 4" maximum page 9-21 L 140-1 Grass and Aquatic plants Table 4.3.713 King County 0.01' Drop in 100 Ft run 91 % Effective Impervious Area Table 4.1 Factor for 100% impervious = 0.43 A Abe — IV e 41 22 minutes required on-line facility (not continuous inflow) Outflow 100 Year in channel Depth (ft) 0.29 Hydraulic Gradient 100 Year Flow (ft/ft) 0.0001 Q (cfs) 0.354 V (fts) 0.620 Drainage Control Structure limits 100 year discharge 11/25/01 78:41:48 am Shareware Release page Edmonds Terrace 2 Yr Pavement Discharge BASIN SUMMARY BASIN ID: 2YrPaved NAME: Pavement Area 2Yr SCS METHODOLOGY TOTAL AREA ....... : 0.57 Acres BASEFLOWS: 0'.00 cfs RAINFALL TYPE .... : TYPElA PERV PRECIPITATION .... : 1.50 inches AREA..: 0.00 Acres TIME INTERVAL.....: 15.00 min CN .... : 0.00 TC .... : 0.00 min ABSTRACTION COEFF: 0.20 PEAK RATE: 0.18 cfs VOL: 0.06 Ac-ft TIME: 495 min IMP 0.57 Acres 98.00 6.30 min 11/26/01 11:24:34 am Shareware Release page Edmonds Terrace Pavement Runoff 100 Yr. Biofiltration High Flow BASIN SUMMARY BASIN ID: 100CB2 NAME:,Catch Basin 2 SBUH METHODOLOGY TOTAL AREA ....... : 0.57 Acres BASEFLOWS: 0.00 cfs RAINFALL TYPE .... : TYPElA PERV PRECIPITATION .... : 3.00 inches AREA..: 0.57 Acres TIME INTERVAL .... : 10.00 min CN .... : TC .... : 6.30 min ABSTRACTION COEFF: 0.20 PEAK RATE: 0.35 cfs VOL: 0.13 Ac-ft TIME: 480 min IMP 0.00 Acres 0.00 0.00 min MR, Ul. "S4.4, It, Nt, V Siff b? 4, .'t-, 4r 'NW tt kyl Fill L kOS 11/5/01 3:27:57 pm Shareware Release page 1 Sump Pump Edmonds Terrace BASIN SUMMARY BASIN ID: 100Sump, NAME: Sump Pump Yard Drain SCS METHODOLOGY TOTAL AREA ....... : 0.03 Acres BASEFLOWS: 0.00 cfs RAINFALL TYPE .... : TYPElA PERV PRECIPITATION .... : 3.00 inches AREA..: 0.0 0 Acres TIME INTERVAL .... : 10.00 min CN .... : 0.00 TC .... : 0.00 min ABSTRACTION COEFF: 0.20 PEAK RATE: 0.02 cfs VOL: 0.01 Ac-ft TIME: 500 min Lett SX j tJ I C (\r- IMP 0.03 Acres 98.00 6.30 min NELSON-BOURDAGES a division of Poggerneyer Design Group Edmonds Terrace Sump Stormwater Pump System TDH = (Zb-Za) + Vb/2g + hl hl = [(3.58 - Q)/(D-2.63 - C)]-(1/0.54) * L + Kt(Vb A 2/2G) = FRICTION HEAD + MINOR LOSSES DATE: 5-Nov-01 BY: CJS JOB# 1040C Oufflow Inflow Op (cfs)= 0.07 Q100year(cfs)= 0.02 Qp (gpm) = 32.0 Q 100 year (gpm) 9.0 Qp (MGD) = 0.0461 PIPE D AT PUMP (in) = 1.50 L INSIDE TANK(ft) = 10 PIPE TO CB (in) = 1.50 L OUTSIDE TANK (ft) = 15 C = 130 LLFS EL (ft)(Za) = 441.00 OUTLET IE (Zb) = 447.30 STATIC H (ft) = 6.30 (Zb - Za) SUM K*s: QTY K (ea) TOTAL K BALL CHECK VALVE 1 3.00 3.00 90d ELB 4 0.30 1.20 UNION i 0.25 0.25 45d ELB 1 0.35 0.35 BALL VALVE 1 0.25 0.25 TOTAL K 5.05 PUMP SYSTEM CALCULATIONS LARGE PIPE SMALL PIPE MINOR LOSSES DISCHARGE FRIC HEAD VELOCITY VEL HEAD (SMALL PIPE) STATIC TDH (gpm) (ft) (fps) (ft) (ft) (ft) (ft) Ql 32 2.71 5.81 0.52 2.65 6.30 12.18 Q2 40 4.09 7.26 0.82 4.14 6.30 15.35 MANHOLE SIZING DIA (in) = 48 PUMP ON EL = 440,5 PUMP OFF EL = .439.5 PUMP RATE (gpm) = 32.0 100 YEAR IN (gpm) = 9.0 TIME TO DRAW DOWN (min) = 4.1 TIME TO REFILL (min) = 10.4 SD Pump System.XLSPUMPSYS 11/5/01 4:35 PM I W u(ifulls 0 Pump Characteristics W 0 Pump/Motor Unit Submersible Automatic Model SHEF30A] Horsepower .30 Full Load Amps 8.0 Motor Type Shaded Pole (4 pole) R. P. M. 1550 Phase 0 1 Voltage 115 Hertz 60 Temperature I 20*F Ambient NEMA Design A Insulation Class A Discharge Size 1-1/2" NPT (38mrii) Solids Handling 3/4" (1 9mm) Unit Weight 30 lbs. Power Cord 18/3, SJTW, 20' std. Materials of Construction Handle Stainless Steel Lubricating Oil Dielectric Oil Motor Housing Cast Iron Pump Volute Cost Iron shall Steel Mechanical Shaft Seal Seal faces: Carbon/Ceramic Seal Body: Anodized Steel Spring: Stainless Steel Bellows: Bunci-N Impeller Engineered Thermoplastic Upper Bearing Cast Iron Sleeve Lower Bearing Single Row Bull Bearing Legs Engineered Thermoplastic Fastener Stainless Sleell LnD r1r HYDROMATIC' Pentair Punip Group 1840 Bancy Roacl Ashland, Ohio 44805 Tel: 419-289-3042 Fax: 419-281-4087 www.liyclron)otic.coni ISO 9001 Cerlifiecl Performance Data 9 r 30 6 20 =E 10 0 1 0 L (apadly-U.S. G.P.M. 0 I- Liiels/sewnd 0 10 20 30 40 so 2 Dimensional Data 3' , 112 — — 5' , 7/8 4 (89) (149) 4 718 4 9) 3 (38) NPT 3'- 1 r2 DISCHARGE I (301) 9'- 112 (2 9"-7/8 (250) PUMP ON All dimensions in inches. Metric lor international Use. Component dimensions rpay vlry 1 1/8 inch. Dimensional data not for construction purpose Unless certified. Dimensions and %veights are approximate. On/Off level adjustable. We reserve the right to make revisions to our product and their specifications without notice. (9 1 YYY Hydromalic', Ashlond, Ohio. All Rights Reserved. — Your Authorized Locol Distributor — Item H: W-02-6350 10/99 8M OV ED4, I I r-- V R E C Ell 10 CITY OF EDMONDS J U N 2- 3 19.9.09 121 5TH AVENUE NORTH, EDMONDS, WA 98020 (425) 771-0220 i,;4,L;- RCW 197-11-970 Determination of Nonsignificance (DNS) MITIGATED DETERMINATION OF NONSIGNIFICANCE ENVIRONMENTAL determination for the Construction of a new 48 unit multi -family apartment complex with 2-9--96 off-street parking stalls within a High Density Multiple Residential (RM-1.5) zone (City of Edmonds File ADB-99-80). The site is located at southeast corner of 236 1h Street SW and 84 1h Avenue West and encompasses two legal lots of record for a total area of 1.8 acres. The project includes the demolition of three existing structures: two residences and a garage. The new apartment complex will also require substantial earth work: grading in the amount of 529 cubic yards and fill in the amount of 545 cubic yards, the earth will be moved around the site to limit the amount of imported fill to 16 cubic yards. Proponent: Seth Hale, CDA Architects Location of proposal, including street address if any: southeast comer of 23�ke ,.96W and 84h Avenue W. Lead agency: CITY OF EDMONDS The lead agency for this proposal has deterniined that it does not h e a�ro able significant adverse impact* on the environment. An environmental impact statement is not require CW,43.21.030(2)(c). This decision was made after review of a completed environmental checklist and ormation on file with the lead agency. This information is available to the public on request. '�) 9 There is no comment period for this DN6 XX This DNS is issued under 197-1 ljo"^the lead 11 not act on this proposal for 14 days from the date below. Comments m t e s rnitted by T2! 11999. Responsible Official: Jeffrey S. Wils RECEIVED Position/Title: Current Planning 11 or, Department of Community Services - Planning Division Phone: 771-0220 AUG 2 8 2001 BUILDING DEPT. Address: City of Ed o s, th Avenue North, Edmonds, WA 98020 Date: Signa t'ur;eD, XX You may appeal this determination to Robert Chave, Planning Manager, at 250 5th Avenue North, Edmonds, WA 98020, no later than 19991 by filing a written appeal citing the reasons. You should be prepared to make specific factual objections. Contact Jeffrey S. Wilson to read or ask about the procedures for SEPA appeals. XX Posted on � 1 1999, at the Edmonds Public Library, Edmonds Community Services Building, and the'Edmonds Post Office. Y_X Distribute to "Checked" Agencies on the reverse side of this forni, along with a copy of the Checklist. 998DED.DOC Page I of 2 SKIMEET FILE 6/21/99.SEPA Mailed to the following along with the Environmental Checklist: XX— Environmental Review Section Y—X City of Mountlake Terrace De artment of Ecology Attn.: S�XA Official PW Box 47703 23024 58 Avenue West Olympia, WA 98504-7703 Mountlake Terrace, WA 98043 XX_ City of Lynnwood XX Stevens Ijospital Attn: Darryl Eastin, Senior Planner 21601 76t' Avenue W P.O. Box 5008 Edmonds, WA 98026 Lynnwood, WA 98046 XX Edmonds School District No. 15 — XX Community Transit Attn.: Brent Russell Attn.: Bret Carlstad, Planning and Prope Manager 2042078th Avenue West 1133 164th Street Southwest, #200 Lynnwood, WA 98037. Lynnwood, WA 98036-7400 Y—X ARent: Seth Hale Y—X _ Washington State DOT CDA Architects P.O. Box 55429 TSM&P/Land Developer 15700 Dayton Avenue N Seattle, WA 98155 Seattle, WA 98133 Y—X A Dlicpt/Owner: Stanley Piha 2FJI 4 Avenue, Suite 250 Seattle, WA 98121-2317 Y—X— MITIGATING MEASURES INCORPORATED INTO THE PROPOSAL: 1. TRAFFIC MITIGATION IN THE AMOUNT OF $240.66 PER NEW PM PEAK HOUR TRIP TOWRARDS THE FUTURE IMPROVEMENTS TO THE CITY OF EDMONDS ARTERIAL SYSTEM IS REQUIRED. AN ESTIMATED 23 NEW TRIPS WILL BE GENERATED FROM THE 48 UNIT APARTMENT COMPLEX, REQUIRING $5,535.18 MITIGATION FEE TO BE PAID PRIOR TO BUILDING PERMIT ISSUANCE. Attachments pc: File No. ADB-99-80 SEPA Notebook Page 2 of 2 9980ED.DOC 6/21/99.SEPA rD RECEIVE A. City of Edmonds Dept. of Planning and Community Development APR 1 4 1999 SEPA Review Checklist BACKGROUND 1. Name of proposed project, if applicable: Edmonds Terrace Multi -Family / CDA Prooect # 98061 2. Name of applicant: Seth Hale / CDA Architects Inc. PLANNIN;2 UCr I - 3. Address and phone number of applicant and contact person:_ Carl Pirscher CDA Architects, 19524 Ballinger Way N.E. PO Box 55429 Seattle,WA98155 (206)368-9668 FAX ( 206 368-9558 4. Date checklist prepared: March 5th, 1999 Agency requesting checklist: City of Edmonds 6. Proposed timing or schedule (including phasing), if applicable: Construction is to start in the spring of 2000. 7. Do you have any plans for future additions, expansion, or further activity related to or connected with this proposal? If yes, explain: No. 8. List any environmental information you know about that has been prepared, directly related to this proposal. None that we are aware of. 9 Do you know whether applications are pending for governmental approvals of other proposals directly affecting the property covered by your proposal? If yes, explain. None that we are aware of. (I CJ --e /�. CA - - - 4. . 6 �, : �,QK�kKr �,ksu 10. List any government approvals or permits that will be needed for your proposal, if known. City of Edmonds Public Works. Sewer, Transportation, and Water mitigation fees. City of Edmonds Building Dept. 11. Give brief, complete description of your proposal, including the proposed uses and the size of the project and site. There are several questions later in this checklist that ask you to describe certain aspects of your proposal. You d.o not need to repeat those answers on this page. (Lead agencies may modify this form to include additional specific information on project description.): (Four) two-story 12 unit apartment buildings. Each building is two stories over basement on a site of 1.79 acres. The site consists of 4 buildings with a floor area of 3,560 SF for a total of 14,240 SF site coverage. The unit breakdown is as follows: All Floors: 4 Buildinas 24 —Two Bedrooms (936 S F each) 24 — One Bedroom(781 SF) 12. Location of the proposal. Give sufficient information for a person to understand the precise location of your proposed project, including a street address, if any, and section, township, and .range, if known. If a proposal would occur over a range of area, provide the range or boundaries of the site(s). Provide a legal description, site plan, vicinity map, and topographic map, if reasonably available. While you should submit any plans required by the agency, you are not required to duplicate maps or detailed plans submitted with any permit applications related to this checklist: Site is located at the southeast comer of 236th St SW and 84 1h Ave W within the City of Edmonds with property lines of 300' along 841 and 220' along 236 1h . The subject property also includes a "panhandle" that extends south to 238 1h St SK The panhandle is approximately 35'wide. Aurora Market Place is directly to the east of the subject property. CDA # 98061 -1- B. ENVIRONMENTAL ELEMENTS 1. Earth a. General description of the site (circle one): FLAT, rolling, hilly, steep slopes, mountainous, other b. What is the steepest slope on the site (approximate percent slope)? <6% C. What general types of soils are found on the site (for example, clay, sand, gravel, peat, muck)? If you know the classification for agricultural soils, specify them and note any prime farmland. . - Sandy / loamy / glacier till d, Are there surface indications or history of unstable soils in the immediate vicinity? If so, describe. None identified. e. Describe the purpose, type, and approximate quantities of any filling or grading proposed. Indicate source of fill. Construction of proposed buildings will require ... 417 cu yds(cut) Construction' of some areas of parking/driveway will require .............. 112 cu yds(cut) Total cut quantity ............ 529 cu yds(cut) Construction of other areas of parking/driveways will require ...... 545 cu yds(fill) As is apparent, there is essentially a balance between cuts and fills. This estimate of cut and fill is as shown given that the soils present on the site are'suitable for the purposes indicated. f. Could erosion occur as a result of clearing, construction, or use? If so generally describe. Not probable. The site Is largely flat. Temporary erosion control and sedimentation plan approval required by agency prior to issuance of grading plan and start of construction. The erosion control measures developed as part of the permit plans will be installed prior to large scale grading. 9. Proposed measures to reduce or control erosion, or other impacts to the earth, if any: BIVIP's for temporary erosion control and sedimentation (per future plan submittal) i.e. silt fence, stabilized construction entrance, anchored straw bale, etc. h. About what percent of the site will be covered with impervious surfaces after project construction (for example, asphalt or buildings)? Approximately 56% 2. Air What types of emissions to the air would result from the proposal (i.e., dust, automobile, odors, industrial wood smoke) during construction and when the project is completed? If any, generally describe and give approximate quantities If known. Short term emissions will be generated from heavy construction equipment during the building phase, which is anticipated to last approximately 6 mo.. Construction activities will be limited to those allowed by the City of Edmonds for typical projects of this type (anticipated hours are 8am to 5pm). Long-term traffic emissions will be generated upon completion of the construction project through the duration of the building service lives. CDA # 98061 -2- b. Are there any off -site sources of emissions or odor that may affect your proposal? If so, generally describe. None identified. C. Proposed measure to reduce or control emissions or other impacts to air, if any: Dust control. 3. Water a. Surface: (1) Is there any surface water body on or in the immediate vicinity of the site (including year-round and seasonal streams, saltwater, lakes, ponds, wetlands)? If yes, describe type and provide names. If appropriate, state what stream or river It flows into. No. (2) Will the project require any work over, in, or adjacent to (within 200 feet) the described waters? If yes, please describe and attach available plans. No. (3) Estimate the amount of fill and dredge material that would be placed in or removed from surface water or wetlands and indicate the area of the site that would be affected. Indicate the source of fill material. None anticipated. (4) Will the proposal require surface water withdrawals or diversions? Give general description, purpose, and approximate quantities if known. No. (5) Does the proposal lie within a I 00-year floodplain? If so, on the location on the site plan. No. (6) Does the proposal involve any discharges of waste materials to surface waters? If so, describe the type of waster and anticipated volume of discharge. No. b. Ground: (1) Will ground water be withdrawn, or will water be discharged to ground water? Give general description, purpose, and approximate quantities if known. No. CDA # 98061 .3 . 46 'J . 0 0 3110 — - - . . 1. - (2) Describe waste material that will be discharged into the ground from septic tanks or other sources, If any (for example: Domestic sewage; Industrial, containing the following chemicals...; agricultural; etc.). Describe the general size of the system, the number of such systems, the number of houses to be serviced (if applicable), or the number of animals or humans the system(s) are expected to serve. Does not apply C. Water Runoff (including storm water): (1) Describe the source of runoff (including storm water) and method of collection and disposal, if any (include quantities, if known). Where will this water flow? Will this water flow into other waters? If so, describe. Quantities of runoff are from roof areas and parking/driveway areas. The City of Edmonds requires that runoff from parking/driveway areas receive water quality treatment primarily through the use of a blo-swale. Therefore the storm water system designed for this project will direct runoff from the parking/driveway areas first through a blo-swale. Runoff from roof areas does not require bio-swale treatment. The City also requires all runoff, from parking/driveway and roof areas to be controlled which means the use of a detention system will keep the runoff amounts from the subject property as a whole no greater after development than before development. Runoff will be directed by the storm drainage to and released at the point of collection that it would have before development. This release point is into the existing public system located on the north side of 2381 St SW. The runoff from the subject project enters the public storm system at 238th St SW then eventually into Puget sound. (2) Could waste materials enter ground or surface waters? If so, generally describe. Waste materials are generally not considered to enter runoff water from roof areas. Runoff from parking/driveways are considered to be contaminated with oils/grease from automobiles. d. Proposed measures to reduce or control surface, ground, and runoff water impacts, If any: To reduce or eliminate the affects of this contamination the City of Edmonds requires the use of the aforementioned bio-swale. 4. PLANTS a. Check or circle types of vegetation found on the site: — X deciduous tree: alder, maple, aspen, other — X evergreen tree: fir, cedar, pine, other shrubs grass pasture crop or grain wet soil plants: cattail, buttercup, bulrush, skunk cabbage, other water plants; water Illy, eelgrass, mil foil, other other types of vegetation b. What kind and amount of vegetation will be removed or altered? Much of the existing landscaping will be removed with the exception of those existing trees indicated to be saved. Other existing specimen shrubs will be retained as appropriate. C. List threatened or endangered species known to be on or near the site. None identified. CDA # 98061 -4- I d. Proposed landscaping, use of native plants, or other measures to preserve or enhance vegetation on the site, if any: Existing appropriate vegetation will be retained and new landscaping will be installed to meet or exceed City of Edmonds standards. 5. Animals a. Underline any birds and animals which have been observed on or near the site or are known to be on or near the site: BIRDS: hawk, heron, eagle, songbirds, other: thrush, sparrow. robin MAMMALS: deer, bear, elk, beaver, other: deer mouse FISH: bass, salmon, trout, herring, shellfish, other: b. List any threatened or endangered species known to be on or near the site. None identified. C. Is the site part of a migration route? If so, explain. None identified d. Proposed measures to preserve or enhance wildlife, if any: Retained trees in addition to proposed new landscaping will provide nesting and forage opportunities for wildlife. 6. Energy and Natural Resources a. What kinds of energy (electric, natural gas, oil, wood stove, solar) will be used to meet the completed project's energy needs? Describe whether it will be used for heating, manufacturing, etc. Electricity to be used for Heating of units. Electricity will also be used for power and lighting. b. Would your project affect the potential use of solar energy by adjacent properties? If so, generally describe. No it will not. C. What kinds of energy conservation features are included in the plans of this proposal? List other proposed measures to reduce or control energy impacts, if any: Lighting, HVAC and building envelope will meet or exceed residential energy code requirements. 7. Environmental Health a. Are there any environmental health hazards, including exposure to toxic chemicals, risk of fire and explosion, spill, or hazardous waste, that could occur as a result of this proposal? If so, describe. Normal Fire, Public safety, and Emergency Medical requirements associated with any residential activity. Describe special emergency services that might be required. Police, Fire and Emergency Medical. CDA # 98061 5, I (2) Proposed measures to reduce or control environmental health hazards, if any: Building and access will be designed to meet or exceed U.B.C. standards for construction and occupancy. Extra tax dollars generated will tend to mitigate any additional requirements for municipal services. b. Noise (1) What types of noise exist in the area which may affect your project (for example: traffic, equipment, operation, other)? Existing traffic noise from 84th Ave. W. & 236th St. S.W. will not be a concern. (2) What types and levels of noise would be created by or associated with the project on a short-term or a long-term basis (for example: traffic, construction, operation, other)? Indicate what hours noise would come from the site. Short-term noise will be generated from heavy construction equipment during the building phase, which is anticipated to last approximately 6 months. Construction activities will be limited to those allowed by the City of Edmonds for projects of this type (between hours of 7am and 5pm). Traffic noise associated with a normal residential project of this size will exist upon completion. (3) Proposed measures to reduce or control noise impacts, if any: Restrict short-term noise associated with large construction equipment to normal working daylight hours. 8. Land and Shoreline Use a. What is the current use of the site and adjacent properties? (Two) single-family residences and 1 garage currently occupy the site. b. Has the site been used for agriculture? If so, describe. Do not know C. Describe any structures on the site. (Two) single-family residences and 1 garage currently occupy the site. d. Will any structures be demolished? If so, what? Existing homes and garage will be demolished. e. What is the current zoning classification of the site? RM 1.5 f. What is the current comprehensive plan designation of the site? Do not know. Wy q9 9. If applicable, what is the current shoreline master program '�OWi 03 designation of the site? Does not apply h. Has any part of the site been classified as an "environmentally sensitive" area? If so, specify. Does not apply CDA # 98061 .6- Approximately how many people would reside or work in the completed project? 77-110 persons j. Approximately how many people would the completed project displace? The two existing single family homes located on site will be demolished. The current owners are selling their property and relocating. k. Proposed measures to avoid or reduce displacement impacts, if any: Does not apply Proposed measures to ensure the proposal Is compatible with existing and projected land uses and plans, if any: Project complies with zoning designation and all zoning development agreements. 9. Housing a. Approximately how many units would be provided, if any? Indicate whether high, middle, or low-income housing. 48 units of middle income multi -family rental housing. 1b. Approximately how many units, if any, would be eliminated? Indicate whether high, middle, or low-income housing. Two single family homes. C. Proposed measures to reduce or control housing impacts, if any: The new housing proposed will offset the demolition of the existing dwelling unit. 10. Aesthetics a. What is the tallest height of any proposed structure(s), not including antennas; what is the principal exterior building material(s) proposed? Exterior materials proposed are imitation river rock, vinyl siding wall materials, and wood trim to a maximum height of 30 feet. b. What views in the immediate vicinity would be altered or obstructed? Does not apply C. Proposed measures to reduce or control aesthetic impacts, if any: Landscaping and Architectural design. 11. Light and Glare a. What type of light or glare will the proposal produce? What time of day would it mainly occur. Parking lot lighting. Nighttime. b. Could light or glare from the finished project be a safety hazard or interfere with views? No, lighting selection will be controlled for glare and cut off. C. What existing off�site sources of light or glare may affect your proposal? None that we are aware CDA # 98061 .7- d. Proposed measures to reduce or control light and glare impacts, if any: Lighting will be designed to control glare and utilize fixtures. 12. Recreation a. What designated and informal recreational opportunities are in the immediate vicinity? None that we are aware b. Would the proposed project displace any existing recreational uses? If so, describe. Does not apply Proposed measures to reduce or control impacts on recreation, including recreation opportunities to be provided by the project or applicant, if any: Does not apply. 13. Historic and Cultural Preservation. a. Are there any places or objects listed on, or proposed for, national, state, or local preservation registers known to be on or next to the site? If so, generally describe. Does not apply b. Generally describe any landmarks or evidence of historic, archaeological, scientific, or cultural importance known to be on or next to the site. Does not apply C. Proposed measures to reduce or control Impacts, if any: Does not apply 14. TRANSPORTATION a. Identify public streets and highways serving the site, and describe proposed access to the existing street system. Show on site plan, if any. Access by way of common drive point from 84th Ave. W and 236 St. SW. (see site plan). Egress only to 238 th St. SW b. Is site currently served by public transit? If not, what Is the approximate distance to the nearest transit stop? Yes, public transit runs along 84 1h Ave W. C. How many parking spaces would the completed project have? How many would the project eliminate? 96 will be required for this project. The existing site has one double -car garage which will be demolished. d. Will the proposal require any new roads or streets, or improvements to existing roads or streets, not including driveways? If so, generally describe (indicate whether public or private). Yes, Right of Way improvements including shoulder, curb, gutter and sidewalk will be required at property perimeter. (ZPA" CDA # 98061 8- b(A e. Will the project use (or occur in the immediate vicinity of) water, rail, or air transportation? If so, generally describe. Does not apply How many vehicular trips per day would be generated by the completed project? If known, indicate when peak volumes would occur. Included in traffic study. 9. Proposed measures to reduce or control transportation impacts, if any: Encourage use of public transportation by developing better pedestrian connections, offering ridership information in Manager's Office. 15. Public Services a. Would the project result in an increased need for public services (for example: fire protection, police protection, health care, schools, other)? If so, generally describe. Fire & police impacts typical for this type of residential development b. Proposed measures to reduce or control direct impacts on public services, if any. The proposal will generate additional tax revenues for the City of Edmonds. Proposed structures will include both fire and motion detector alarm systems. The buildings will be designed in full compliance with NFP-13 and the U.B.C.. 16. Utilities a. Circle utilities currently available at the site: electricity, natural gas, water, refuse service, telephone, sanita!)t sewer, septic system, other. b. Describe the utilities that are proposed for the project, the utility providing the service and the general construction activities on the site or in the immediate vicinity which might be needed. Local Utilities are currently sized to meet the requirements of this project, and it is our understanding that there will not have to be any special new upgrade to serve this parcel. C. SIGNATURE The above answers are true and complete to the best of my knowledge. I understand that the lead agency is relying on them to make its decision. Signature:— CDA Architects Inc. Date Submitted: � - I -L � � - CDA # 98061 JUN-16-1999 16:34 dt�b ! 0 B92) Skly"', H TH&FFOC CON SU L7& HIM' TRAFFIC ENGINEERING e TRANSPORTATION PLANNING k1712 PACIFIC AVENUE - SUITE 100 * EVERErr, WA 98201 - PH: (42S) 339-8266 - FAX: (42S) 256-2922� June 9, 1999 Mr. Gordy Hyde City of Edmonds, Engineering Dept. 121 - 5th Avenue North Edmonds, Washington 98020 RE: Edmonds Terrace Multi -Family; GTC Project No. 99-169 Revised Off -Site Mitigation for Proposed Development Dear Mr. Hyde: Per our phone conversation, Gibson Traffic Consultants (GTQ has revised the off -site mitigation proposed in our March 26th traffic impact analysis for Edmonds Terrace Multi -Family. The City has a mitigation fee of S240.66 per weekday p.m- peak hour trip generated by developments in the site vicinity impacting capacity improvements- This fee is based on transportation improvement projects included in the City's 6-Year TIP. Per the trip distribution in our traffic study, Edmonds Terrace Multi -Family would add 23 weekday p.m. peak hour trips to improvement projects. The subject project would add 20 p.m - peak trips to SR-99 corridor improvement projects an * d 3 p.m. peak trips to the 220th Street SW/84th Avenue W signal project. Thus, Edinonds Terrace Multi -Family project should pay the City of Edmonds a mitigation fee of S5.535.1 (23 p.m. peak trips x S240.66/p.m. peak trip). We trust that this memorandum letter adequately addresses the off -site mitigation issues for the proposed Edmonds Terrace Multi -Family development. If you have any questions on GTC's analysis or findings, please feel free to call me at (425) 339-8266. Thanks, Gordy. Sincerely, GrBsON TRAFnc CONSULTANTs, INc. P.S. L�IZ52� z�70z�� Carter A. Danne Transportation Planning Engineer XC: Stanley Piha, R & P Investment Co. LLC Seth Hale, CDA Architects COUNTS/SURVEYS * SITE IMPACTS * LOS ANALYSIS - EIS - HEARINGS - SAFETY - SIGNALS - PARKING TOTAL P.02 ADJAC-ENT PROPERTY OWNERS LIST Attach this notafted declaration to the adjacent property owners list. On my oath, I certify that the names and addresses provided represent all properties located within 300 feet of the subject property. Signature of Applicant' or'Applic&t's Representative Subscribed and sworn to before me this day of 19 MARCIA IINKINS A 10 �M' Nota* Public -in an�Cf6r the State of Washingto C4 sit 9. Residing.at AP0.doc\LATempVorms 312704-2-048-0008 312704-2-049-0007 312704-2-053-0000 Marjorie C. Lyon Betty C; Holt John B. Pahre 21624 84TH Ave W '23522 84TH Ave W 23504 84TH Ave W Edmonds, WA 98026 Edmonds, WA 98026 'Edmonds, WA 98026 312704-2-071-0008 4191-000-001-00-00 4191-000-002-00-09 Kevin L. Prentiss Doreen A. Sutton James Dousbaugh 8415 235TH PL SW 8408 236TH ST SW 8414 236TH ST,SW Edmonds, WA 98026 Edmonds, WA 98026 Edmonds, WA 98026 4191-000-003-00-08 4191-000-004-00-07 4519-001-004-01-09 C N Slaughter Thomas L. Durbin AMB INST REALTY ADV 8420 236TH ST SW 8426 236TH ST SW PO Box 565048 Edmonds, WA 98026 Edmonds, WA 98026 Dallas, TX 75356 4519401-009-00-05 4519-001-012-02-08 4519-001-012-03-07 R & P Investment Co. James B. Adams R & P Investment Co. 2101 4TH Ave Suite 250 23707 84TH Ave W 2101 4TH Ave Suite 250 Seattle, WA 98121 Edmonds, WA 98026 Seattle, -WA 98121 4519-001-013-02-07 4519-001-014-01-07 4519-002-007-00-05 Rogelio Mercado Joseph Basco Transpac Devel Inc 15332 Heintz Ave SE 19129 Olympic View Dr 559 Kirkland Way #201 Monroe, WA 98272 Edmonds, WA 98020 Kirkland, WA 98033 4519-002-009-00-03 4633-001-001-01-03 4633-001-001-02-02 Salamonsen Const Co Susan C. Brennan Kori Myers PO Box 177 23626 84TH Ave W 23618 84TH Ave W Lynnwood, WA 98046 Edmonds, WA 98026 Edmonds, WA 98026 4633-001-002-00-03 4633-001-002-01-02 4633-001-003-01-01 Chrastka/Kontney Ann B. Lee Charles A. Foy 8504 236TH ST SW 23622 84TH Ave W 8506 236TH ST SW Edmonds, WA 98026 Edmonds, WA 98026 Edmonds, WA 98026 4633-008-001-01-08 4633-008-001-02-07 4633-008-001-03-06 Mary Ann Bakken Jose Delgado Donald F. Miller 23727 84TH Ave W 23720 84TH Ave W 8415 238TH St SW Edmonds, WA 98026 Edmonds, WA 98026 Edmonds, WA 98026 4633-008-001-04-05 4633-008-001-05-04 4633-008-002-00-08 Dyson E. Wilkison Jose Delgado Mark J. Vanpelt 23706 84TH Ave W 23720 84TH Ave W 8421 238TH ST SW Edmonds, WA 98026 Edmonds, WA 98026 Edmonds, WA 98026 4633-008-003-00-07 Daniel P. Giarde 23910 107TH PL W Edmonds, WA 98020 5767-000-025-08-05 Christ Evan Luth Exemp 23525 84TH Ave W Edmonds, WA 98026 7784-000-002-00-05 Lois Whitney 8423 236TH ST SW B Edmonds, WA 98026 4633-009-001-03-04 Donald Jackson 23814 84TH Ave W Edmonds, WA 98026 4633-008-003-01-06 4633-008-003-02-05 Ted & Pauline Akers David Angiuli 8427 238TH ST SW 8425 238TH ST SW Edmonds, WA 98026 Edmonds, WA 98026 5767-000-025-09-04 Christ Evan Lutheran Church 7784-000-001-00-06 23525 84TH Ave W Lois Whitney Edmonds, WA 98026 8423 236TH ST SW Edmonds,.WA 98026 4633-009-001-01-06 4633-009-001-02-05 Korean Unit Preby Church Shirley Gauthier 23828 84TH Ave W 23820 84TH Ave W Edmonds, WA 98026 Edmonds, WA 98026 4633-009-001-04-03 4633-009-002-00-06 Gerald Scott Dale & Norma Hanberg 23808 84TH Ave W 650 13TH Way SW Edmonds, WA 98026 Edmonds, WA 98020 312704-2-048-0008 4519-001-004-01-09 4519-'001-009-00-05 RESIDENT RESIDENT RESIDENT 23514 84TH Ave W 23632 Hwy 99 23625 84TH Ave W Edmonds, WA 98026 Edmonds, WA 98020 Edmonds, WA 98026 4519-001-013-02-07 4519-001-014-01-07 4519-002-007-00-05 RESIDENT RESIDENT RESIDENT 23717 84TH Ave W 23721 84TH Ave W 23830 Hwy 99 Edmonds, WA 98026 Edmonds, WA 98026 Edmonds, WA 98020 4633-008-001-01-08 4633-008-003-00-07 4633-009-002-00-06 RESIDENT RESIDENT RESIDENT 23728 84TH Ave W 8429 238TH ST SW 8422 238TH ST SW Edmonds, WA 98026 Edmonds, WA.98026 Edmonds, WA 98026 4519-002-009-00-03 4519-002-009-00-03 4519-002-009-00-03 RESIDENT '�RESIDENT RESIDENT - 23809 84TH Ave W #101 23809 84TH Ave W #102 23809 84TH Ave W #103 Edmonds, WA 98026 Edmonds, WA 98026 Edmonds, WA 98026 4519-002-009-00-03 4519-002-009-00-03 4519-002-009-00-03 RESIDENT RESIDENT RESIDENT 23809 84TH Ave W #104 23809 84TH Ave W #105 23809 84TH Ave W #106 Edmonds, WA 98026 Edmonds, WA 98026 Edmonds, WA 98026 4519-002-009-00-03 4519-002-009-00-03 4519-002-009-00-03 RESIDENT RESIDENT RESIDENT 23809 84TH Ave W #107 23809 84TH Ave W #108 23809 84TH Ave W #209 Edmonds, WA 98026 Edmonds, WA 98026 Edmonds, WA 98026 4519-002-009-00-03 4519-002-009-00-03 4519-002-009-00-03 RESIDENT RESIDENT RESIDENT 23809 84TH Ave W #210 23809 84TH Ave W #211 23809 84TH Ave-W #212 Edmonds, WA 98026 Edmonds, WA 98026 Edmonds, WA 98026 4519-002-009-00-03 4519-002-009-00-03 4519-002-009-00-03 RESIDENT RESIDENT RESIDENT 23809 84TH Ave W #213 23809 84TH Ave W #214 23809 84TH Ave W #215 Edmonds, WA 98026 Edmonds, WA 98026 Edmonds, WA 98026 4519-002-009-00-03 4519-00M09-00-03 4519-002-009-00-03 RESIDENT RESIDENT RESIDENT 23809 84TH Ave W #216 23827 84TH Ave W #117 23827 84TH Ave W #118 Edmonds, WA 98026 Edmonds, WA 98026 Edmonds, WA 98026 4519-002-009-00-03 4519-002-009-00-03 4519-002-009-00-03 RESIDENT RESIDENT RESIDENT 23827 84TH Ave W #119 23827 84TH Ave W #120 23827 84TH Ave W #221 Edmonds, WA 98026 Edmonds, WA 98026 Edmonds, WA 98026 4519-002-009-00-03 RESIDENT 23827 84TH Ave W #222 Edmonds, WA 98026 4519-002-009-00-03 RESIDENT 23821 84TH Ave W Edmonds, WA 98026 4519-002-009-00-03 RESIDENT 23827 84TH Ave W #223 Edmonds, WA 98026 4519-002-009-00-03 RESIDENT 23827 84TH Ave W #224 Edmonds, WA 98026 R E 1C.! E I V E D City of Edmonds NOV RX --� - 0B?T CRITICAL AREAS CHECKLIST The Critical Areas Checklist contained on this form is to be filled out by any person preparing a Development Permit Application for the City of Edmonds prior to his/her submittal of a development permit to the City. The purpose of the Checklist is to enable City staff to determine whether any potential Critical Areas are, 'or may be, present on the subject property. The information needed to complete the Checklist should be easily available from observations of the site or data available at City Hall (Critical Areas inventories, maps, or soil surveys). An applicant, or his/her representative, must fill out the checklist, sign and date it, and submit it to the City. The City will review the checklist, make a precursory site visit, and make a determination of the subsequent steps necessary to complete a development permit application. Please submit a vicinity map along with the signed copy of this form to assist City staff in finding and locating the specific piece of property described on this form. In addition, the applicant shall include other pertinent infor m-ation (e.g., site plan, topography map, etc.) or studies in conjunction with this Checklist to assist staff in completing their preliminary assessment of the site I have completed the attached Critical Areas Checklist and attest that the answers provided are factual, to the best of my knowledge (fill out the appropriate column below). Owner/Applicant: Name Street Address city S tate Zip Telephone Signature � Date Applicant Representative: Name 'E5 S L4 2- <7- Street Address ��M,cr7- city State Zip Z;�p 3 13 Telephn n Signature �J6 V Date (over) c:recepdon\jana\cac1.doc UA P I LPM IYU. — —If I C71 UZP-�, Critical Areas Checklist -------------------------------------------------------------- Site Information (soils/topography/hydrology/vegetation) s 6 -Tl+ I Site Address/Location: 2. Property Tax Account Number- 4:51 0�471 Approximate Site Size (acres or s!quare feet): �5;: 4. Is this site currently developed? A yes; —no. If yes; how is site developed? Z�-_s I K-)-T- i kL 63 1 5. Describe the general site topography. Check all that apply. X Flat: less than 5-feet elevation change over entire site. Rolling: slopes on site generally less than 15% (a vertical rise of 10-feet over a horizontal distance of 66-feet). I Ti I, 11y: r'l slopes present on site of more than 15% and less than 30% ( a vertical rise of I 0-feet over a horizontal distance of 3 )3 to 66-feet). Steep: grades of greater than 310% present on site (a vertical rise of I 0-feet over a horizontal distance of less than 33-feet). Other (please describe): 6. Site contains areas of year-round standing water: Approx. Depth: 7. Site contains areas of seasonal standing water: Approx. Depth: What season(s) of the year? S. Site is in the floodway t---3 0 floodplain of a water course. 9. Site contains a creek or an area where water flows across the arounds surface? Flows are year- 0 round? 0 -Flows are seasonal? _1-� (D (What time of year? 10. Site is primarily: forested meadow ;shrubs X mixed urban landscaped (lawn,shrubs etc) X 11. Obvious wetland is present on site: yQ C) DET.tRMINATION ^ca_chk doc; Rev 10/03/97 0 - 0 PLANNING REVIEW CHECKLIST ,Commercial / MultiFamily Pro*ects SITE ADDRESS: 0 ZONING: Vill - PROJECT DESCRIPTION: USE(S) PROPOSED: ALLOWED?: 4Ly4s,2 SEPA REQUIRED?: DETERMINATION?:-r D�NS CRITICAL AREAS #: LIJ DETERMINATION?: �Waiyer SHORELINE REQUIRED?: No DETERMINATION?: NIA SUBDIVISION? - LOT AGGREGATION REQUIRED?: ad ye �: ) LEGAL NONCONFORMING LAND USE DETERMINATION ISSUED NIA CUP File: L2 'To Allow What Uses?: DENSITY: Maximum Units Allowed:. Proposed: MAXIMUM FLOOR AREA or LOT COVERAGE: Maximum Allowed: Proposed: -,70 BUILDING HEIGHT: Datum Point: ft�2 it rt 6E L� Datum Elevation: / 6-0 Four Corner Elevations: �2'j I= rLH Avprage Grade: Ift, rA MaximumAllowed: Proposed Height:_,. - Requesting Modulation Allowance?:. Yes Modulation Height: Elevator Penthouse > 3 feet over height limit? No If so,VAR#: C:WILES1Reports1ADBWeveAv checklist Com.doc Revised: April 4, 200i SETBACKS: Setback type (street) North South 151 East D-6— West Required Setbacks 10 Proposed Setbacks Street map checked for additional setback required? Yes 31 pWIXK,�, What site improvements are proposed in the setbacks[] Wjg_�7 , PARKING: Proposed Use Parking Ratio (Sq. Ft., Emp) Stalls Required 1A H VH Total Parking Required: Parking ProposedEj DESIGN REVIEW: Applicable Standards and/or District Requirementso Building Design: (check items that apply) F-1 General: F-1 Materials: El Shapes and Forms: F-I Details and Fenestratio n: F-1 Size, Height and Bulk: El Transitions: Site Design: El Site Organization: El Parking: CIFILESWeports�ADB�Reveiw checklist Coin.doc Revised: April 4, 2001 Y4 RETURN ADDRESS: City of Edmonds, City Clerk 121 5th Avenue North Edmonds, WA 98020 CONFORMED Copy 200208230980 0812312002 04:53 PM Snohomish P- 0003 RECORDED County DECLARATION OF RESTRICTIVE COVENANT MULTI -FAMILY RESIDENTIAL Reference#: 41 W-401161�� & 4�-1<11 �/7 Grantor(s): (1)��4>14Z--* -(2 Additional on pg. Legal Description (abbreviated): Sec-�( Twn —23—Rng-�Qtr-��s� OR Lot ----Block Plat Assessor's Tax Parcel ED#(s): (1 0 -4017v( xFj - 6 W45 (2 —Assessor's Tax Parcel 1D# not yet assigned cLe� fA ez. W�EREAS, are the owners of the following described real estate in the City of Edmonds, to wit: Property Address: (_1 (e-0 I Legal Description: W"All Assessor's Tax Parcel ID # (s)AS15 -00 1— * — AUTHORIZED FOR RECORDING C' Of Edmonds By: Date 911,401120- -,$ 1 1 - Page of iWA-1dn11!W16TW� I � 0 G-A D �3CR-PT ON PARCEL A: LOTS 1, 10, ANJ�) 11 IN 5L.00K I OF FRUITLAND ACRES TO LAKE 5ALLINOER, ACCORDING5 TO- FLAT RECORDED IN VOLUME' 10 OF FLATS AT FA&E(5) 47, IN SNOHOM15H COUNTN(, NASHINC7TON; EXCEPT THE EAST 120.00 FEET THEREOF. ol PARCEL E3: THE V�EST 60.00 FEET OF THE EAST 250 FEET OF LOT 12 IN BLOC< I OF FRUITLANI�). ACRES TO LA<E.E3ALLIN6ER, ACCORDINO TO FLAT RECORDED IN VOLU�IE 10 OF FLATS AT PA6E(S) 411 IN SNOHOMISH COUNT"(, �NASHIN&TON; EXCEPT TH E NEST 5.4-7 FEET OF THE NORTH 30.00 FEET THEf;ZEOF; ALSO, THE �NE5T 30 FEET OF THE EAST 220.00 FEET OF LOT.15 AND THE �NE5T 55.00 FEET OF THE EAST 225.00 FEET OF LOT 14 IN SAIP BLOCK 1. TAX I.D. #: 4511�-1-001-0001-0005 451q-001-012-0501 WHEREAS, the above named owners are desirous of imposing I a restrictive covenant upon said premises in compliance with Section 19.00.040 of the Edmonds Community Development Code. WITNESSETH, that for and in consideratio ' n of the premises, the above named owners do hereby declare and grant to the City of Edmonds as Grantee the following restrictive covenant, to -wit: That at the time of the execution of this Covenant the Grantors have agreed to the Ordinance of the City of Edmonds provide that'no building for multiple family housing may be erected on subject property containing more than is 7— units. Said Covenant shall be binding upon all'present and future owners of said real estate and their heirs, successors and assigns. DATED this dayof ;:2 e� x 1---7'—' C-0 GRANTOR ez— e, 1-k--) 4? GRANTOR State of Washington )ss County o1EkQ)rM�\L-\>A\ ) I certify that I know or * have satisfactory evidence that Ek2" ' V)31 signed this instrument, on oath stated that he/she was author to execute the instrument and acknowledged it as the Q " 1�1 17_�V --(title) of &Imazc���CA_4name of party on behalf on whom instrument Was executed) to be the free and voluntary act of such party for the uses and purposes mentions in this instrument. Subscribed and sworn to before me this �:_� day of . NY -D -C � D \ . Notary Public in and for the State of Washington. e:;7—..P' My commission expires- \'_2 AUTHORIZED FOR RECORDING &2y of Edmonds By __Date:1�A/4'//)-z' Page of U\TEMMUILDINGTORMSMSTRICT OEOTECH CONSULTANTS, INC. R & P Investments Co., LLC c/o CDA Architects, Incorporated P.O. Box 55429 ,-Seattle, Washington 98155 I Attention: Seth Hale Subject: Transmittal Letter — Geotechnical Engineering Study Proposed Edmonds Terrace Multi -Family Project 236XX — 84th Avenue West Edmonds, Washington Dear Mr. Hale: 13256 Northeast 20th Street, Suite 16 Bellevue, Washington 98005 (425) 747-5618 FAX (425) 747-8561 August 20, 2001 JN 01248 RECEIVED AUG 2 12001 cu.k, INC. We are pleased to present this geotechnical engineering report for the multi -family development to be constructed at 236XX — 84th Avenue West in Edmonds, Washington. The scope of our work consisted of exploring site surface and subsurface conditions, and then developing this report to provide recommendations for general earthwork and design criteria for foundations, retaining walls, and pavements. This work was authorized by your acceptance of our proposal, P-5561, dated July 20,2001. The attached report contains a discussion of the study and our recommendations. Please contact us if there are any questions regarding this report, or for further assistance during the design and construction phases of this project. SES/JHS: esm Respectfully submitted, GEOTECH CONSULTANTS, INC. 5James H. Strange, Jr. Senior Geotechnical Engineer RECEIVED AUG 2 8 2001 BUILDING DEPT, STREET FILE GEOTECH CONSULTANTS, INC. GEOTECHNICAL ENGINEERING STUDY Proposed Edmonds Terrace Multi -Family Project 236XX — 84th Avenue West Edmonds, Washington This report presents the findings and recommendations of our geotechnical engineering study for the site of the proposed Edmonds Terrace multi -family development to be located at 236XX — 84th Avenue West in Edmonds, Washington. We were provided with site plans and a topographic map. CDA Architects along with D. R. Strong developed these plans, which were provided on July 19, 2001. Based on these plans and conversations with CDA, we anticipate that the development will consist of four multi -family residential buildings, with parking and drive access from the surrounding streets. The proposed multi -unit buildings will be two stories over a partially submerged basement. The two eastern buildings will have a footprint approximately 3,560 square feet, while' the two western buildings will have a footprint approximately 4,380 square feet. Building setbacks from the property lines are shown to be at least 10 feet. The remainder of the lot will be used for parking and drive access. All of the buildings are proposed to be slab -on -grade construction with finished floor slabs from elevation 994.00 to 995.75 feet. The parking areas and driveways are proposed to be at, or near, the elevation of the existing grade. Excavation for the proposed structures is anticipated to be less than 5 feet below the existing grades. SITE CONDITIONS SURFACE The Vicinity Map, Plate 1, illustrates the general location of the site. The site is approximately 78,239 square feet in size and is bordered to the north by 236th Street Southwest and to the west by 84th Avenue West. The subject site is generally rectangular in shape with an access easement on the order of 20 feet wide extending south approximately 300 feet. The extension reaches from the southeastern side of the property to give access from 238th Street southwest. Residential property abuts the site to the south with commercial property to the east. Currently, the site is cleared of all vegetation and buildings. The site formerly was developed with two single-family residences with detached garages and several smaller buildings. The residences were burned down by the Edmonds Fire Department during training exercises. One residential footprint is currently marked by a 2-foot depression in surface elevation. The foundation appears to have been removed. Standing water was noted in the depression with some ash and burn evidence on the surface. The foundation of the other northern house was not observed. The existing residence at 23703 — 84th Avenue West appears to be part of the subject property. Based on the development drawings provided, it appears that this existing house will remain and a parking strip will be constructed to the east of the proposed residence. The majority of the site has been graded relatively level. The topography of the site slopes gently to the south with a total elevation change of approximately 6 feet across the entire site. A mound of soil has been placed on the southeastern corner of the property. This mound is approximately 5 feet above the existing grade and appears to consist of recently placed fill soils. GEOTECH CONSULTANTS, INC. R&P Investment Co., LLC. c/b CDA Architects August 20, 2001 SUBSURFACE JN 01248 Page 2 The subsurface conditions were explored by excavating eight test pits at the approximate locations shown on the Site Exploration Plan, Plate 2. Our exploration program was based on the proposed construction, anticipated subsurface conditions and those encountered during exploration, and the scope of work outlined in our proposal. The test pits were excavated on July 31, 2001 with a rubber -tired backhoe. A geotechnical engineer from our staff observed the excavation process, logged the test pits, and obtained representative samples of the soil encountered. "Grab" samples of selected subsurface soil were collected from the backhoe bucket. The Test Pit Logs are attached to this report as Plates 3 through 6. Soil Conditions The test pits encountered 2 to 5 feet of loose topsoil and fill soils below the generally level portion of the site. Test Pit 5 encountered 8 feet of fill soil, however, its surface elevation was approximately 5 feet higher in elevation than the rest of the site. Underlying the loose soils, we observed weathered, silty sand that became gravelly and medium -dense with depth. This soil becomes glacially consolidated and dense to very dense approximately 4 to 8 feet below the existing grade. These dense soils are referred to in this report as glacial till. The till was observed to the maximum depth explored of 12 feet below grade. Groundwater Conditions Perched groundwater seepage was observed at a depth of 4.5 to 7.0 feet. The test pits were left open for only a short time period. Therefore, the seepage levels on the logs represent the location of transient water seepage and may not indicate the static groundwater level. It should be noted that groundwater levels vary seasonally with rainfall and other factors. We anticipate that groundwater could be found in more permeable soil layers within the till and between the near -surface weathered soil and the underlying denser glacial till. The final logs represent our interpretations of the field logs. The stratification lines on the logs represent the approximate boundaries between soil types at the exploration locations. The actual transition between soil types may be gradual, and subsurface conditions can vary between exploration locations. The logs provide specific subsurface information only at the locations tested. The relative densities and moisture descriptions indicated on the test pit logs are interpretive descriptions based on the conditions observed during excavation. The compaction of backfill was not in the scope of our services. Loose soil will therefore be found in the area of the test pits. If this presents a problem, the backfill will need to be removed and replaced with structural fill during construction. GEOTECH CONSULTANTS, INC. R&P Investment Co., LLC. c/o CDA Architects JN 01248 August 20, 2001 Page 3 CONCLUSIONS AND RECOMMENDATIONS GENERAL THIS SECTION CONTAINS A SUMMARY OF OUR STUDY AND FINDINGS FOR THE PURPOSES OF A GENERAL OVERVIEW ONLY MORE SPECIFIC RECOMMENDATIONS AND CONCLUSIONS ARE CONTAINED IN THE REMAINDER OF THIS REPORT. ANY PARTY RELYING ON THIS REPORT SHOULD READ THE ENTIRE DOCUMENT The test pits conducted for this study generally encountered from 2 to 5 feet of loose topsoil and fill soils overlying native, medium -dense, silty sand. This soil becomes gravelly and glacially consolidated glacial till approximately 4 to 8 feet below the existing grade. Based on this, the proposed multi -family residential buildings can be constructed on conventional foundations bearing directly on the medium -dense to dense, native soils, or atop of structural fill placed above this competent soil. Test Pit 5 was located in the southeastern -corner of the site in the location of the suspected fill mound. The elevation of the top of the test pit was approximately 5 feet above the surrounding grade. The test pit encountered approximately 8 feet of loose fill soils over weathered silty sand. The glacial till was observed approximately 10 feet below grade. The fill soil will need to be removed in the building and areas for the construction of the project. The parking and driveways can be constructed on the medium -dense weathered soils underlying the topsoil and fill soils or atop granular fill placed above the medium -dense, native soils. The fill soils observed were loose with a relatively high amount of organic content. Placing the parking and driveways on top of the fill soil could result in significant settlement of the pavement. If not overly wet at the time of placement, the native soils excavated during the grading for the foundations of the buildings could be reused as parking and driveway sub -base. These soils will need to be relatively dry during placement and compacted as described in the Pavement Areas section of this report. A significant geotechnical consideration for development of this site is the overly moist to wet condition of the silty soils. Based on our observations, and the results of our laboratory tests, the moisture contents of the upper on -site soils are significantly above the optimum moisture content necessary for the required structural fill compaction. These fine-grained, silty soils are sensitive to moisture, which makes them impossible to adequately compact when they have moisture contents even 2 to 3 percent above their optimum moisture content. The reuse of these soils as structural fill to level the site will only be successful during hot, dry weather. Aeration of each loose lift of soil will be required to dry it before the lift is compacted. Alternatively, the soil could be. chemically dried by adding lime, kiln dust, or cement, provided this is allowed by responsible building department. Regardless of the method of drying, the earthwork process will be slowed dramatically. The earthwork contractor must be prepared to rework areas that do not achieve proper compaction due to high moisture content. Utility trench backfill in structural areas, such as pavements, must also be dried before it can be adequately compacted. Improper compaction of backfill in utility trenches and around control structures is a common reason for pavement distress and failures. Imported granular fill will be -needed wherever it is not possible to dry the on -site soils sufficiently before compaction. We anticipate excavations for the foundations will be approximately 4 to 5 feet below the existing grade. The only other excavations we anticipate will be for utility trenches and detention vaults. GEOTECH CONSULTANTS, INC. R&P Investment Co., LLC. c/o CDA Architects JN 01248 August 20, 2001 Page 5 Depending on the final site grades, overexcavation may be required below the footings to expose competent, native soil. Unless lean concrete is used to fill an overexcavated hole, the overexcavation must be at least as wide at the bottom as the sum of the depth of the overexcavation and the footing width. For example, an overexcavation extending 2 feet below the bottom of a 2-foot-wide footing must be at least 4 feet wide at the base of the excavation. If lean concrete is used, the overexcavation need only extend 6 inches beyond the edges of the footing. The following allowable bearing pressures are appropriate for footings constructed according to the above recommendations: Where: (1) psf is pounds per square,foot A one-third increase in these design bearing pressures may be used when considering short-term wind or seismic loads. For the above design criteria, it is anticipated that the total post -construction settlement of footings founded on competent, native soil, or on structural fill up to 5 feet in thickness, will be about 1/2 inch, with differential settlements on the order of 1/2 inch in a distance of 50 feet along a continuous footing with a uniform load. Lateral loads due to wind or seismic forces may be resisted by friction between the foundation and the bearing soil, or by passive earth pressure acting on the vertical, embedded portions of the foundation. For the latter condition, the foundation must be either poured directly against relatively level, undisturbed soil or be surrounded by level structural fill. We recommend using the following ultimate values for the foundation's resistance to lateral loading: PARAMETER ULTIMATE I VALUE Coeffici nt of Friction 0.50 Passive Earth Pressure 350 pcf Where: (i) pcf is pounds per cubic foot, and (11) passive earth pressure is computed using the equivalent fluid density. We recommend maintaining a safety factor of at least 1.5 for the foundation's resistance to lateral loading, when using the above ultimate values. PERMANENT FOUNDATION AND RETAINING WALLS Retaining walls backfilled on only one side should be designed to resist the lateral earth pressures imposed by the soil they retain. The following recommended parameters are for walls that restrain level backfill: GEOTECH CONSULTANTS, INC. R&P Investment Co., LLC. clo CDA Architects August 20, 2001 PARAMETER Active Earth Pressure VALUE 35 pcf Passive Earth Pressure 350 pcf Coefficient of Friction 0.50 Soil Unit Weight 130 pcf Where: (1) pcf is pounds per cubic foot, and (ii) active and passive earth pressures are computed using the equivalent fluid pressures. * For a restrained wall that cannot deflect at least 0.002 times its height, a uniform lateral pressure equal to 10 psf times the height of the wall should be added to the above active equivalent fluid pressure. JN 01248 Page 6 The values given above are to be used to design permanent foundation and retaining walls only. The passive pressure given is appropriate for the depth of level structural fill placed in front of a retaining or foundation wall only. The values for friction and passive resistance are ultimate values and do not include a safety factor. We recommend a safety factor of at least 1.5 for overturning and sliding, when using the above values to design the walls. Restrained ' wall soil parameters should be utilized for a distance of 1.5 times the wall height from corners or bends in the walls. This is intended to reduce the amount of cracking that can occur where a wall is restrained by a corner. The design values given above do not include the effects of any hydrostatic pressures behind the walls and assume that no surcharges., such as those caused by slopes, vehicles, or adjacent foundations will be exerted on the walls. If these conditions exist, those pressures should be added to the above lateral soil pressures. Where sloping backfill is desired behind the walls, we will need to be given the wall dimensions and the slope of the backfill in order to provide the appropriate design earth pressures. Heavy construction equipment should not be operated behind retaining and foundation walls within a distance equal to the height of a wall, unless the walls are designed for the additional lateral pressures resulting from the equipment. The wall design criteria assume that the backfill will be well -compacted in lifts no thicker than 12 inches. The compaction of backfill near the walls should be accomplished with hand -operated equipment to prevent the walls from being overloaded by the higher soil forces that occur during compaction. Retaininci WaH Backfill and Waterproofin Backfill placed behind retaining or foundation walls should be coarse, free -draining structural fill containing no organics. This backfill should contain no more than 5 percent silt or clay particles and have no gravel greater than 4 inches in diameter. The percentage of particles passing the No. 4 sieve should be between 25 and 70 percent. If the native silty sand is used as backfill, a minimum 12-inch width of free -draining gravel and a drainage composite similar to Miradrain 6000 should be placed against the backfilled retaining walls. The drainage composites should be hydraulically connected to the foundation drain system. Free -draining backfill or gravel should be used for the entire width of the backfill where GEOTECH CONSULTANTS, INC. R&P Investment Co., LLC. c/b CDA Architects August 20, 2001 JN 01248 Page 7 seepage is encountered. For increased protection, drainage composites could be placed along cut slope faces, and the walls backfilled entirely with free -draining soil. The purpose of these backfill requirements is to ensure that the design criteria for a retaining wall are not exceeded because of a build-up of hydrostatic pressure behind the wall. The top 12 to 18 inches of the backfill should consist of a compacted, relatively impermeable soil or topsoil, or the surface should be paved. The ground surface must also slope away from backfilled walls to reduce the potential for surface water to percolate into the backfill. The section entitled GENERAL EARTHWORK AND STRUCTURAL FILL contains recommendations regarding the placement and compaction of structural fill behind retaining and foundation walls. The above recommendations are not intended to waterproof the below -grade walls. The performance of subsurface drainage systems will degrade over time. Therefore, waterproofing should be provided where moist conditions or some seepage through the walls are not acceptable in the future. This typically includes limiting cold-joihts and wall penetrations, and using bentonite panels or membranes on the outside of the walls. Applying a thin coat of asphalt emulsion is not considered waterproofing, but will only help to prevent moisture, generated from water vapor or capillary action, from seeping through the concrete. With any project, adequate ventilation of basement and crawi space areas is important to prevent a build up of water vapor that may be transmitted through concrete wails from the surrounding soil. SLABS -ON -GRADE The building floors may be constructed as slabs -on -grade atop the native, medium -dense, silty sand, the dense to very dense glacial till, or on structural fill placed above competent native soils. The subgrade soil must be in a firm, non -yielding condition at the time of slab construction or underslab fill placement. Any soft areas encountered should be excavated and replaced with select, imported structural fill. All slabs -on -grade where moisture transmission through the slab is of concern should be underlain by a capillary break or drainage layer consisting of a minimum 4-inch thickness of coarse, free - draining structural fill with a gradation similar to that discussed in PERMANENT FOUNDATION AND RETAINING WALLS. As noted by the American Concrete Institute (ACI) in Section 3.2.3 of the Guides for Concrete Floor and Slab Structures, proper moisture protection is desirable immediately below any on -grade slab that will be covered by tile, wood, carpet, impermeable floor coverings, or any moisture -sensitive equipment or products. ACI also notes that vapor retarders, such as 6-mil visqueen, are typically used. A vapor retarder is defined as a material with a permeance of less than 0.3 US perms per square foot (psf) per hour, as determined by ASTM E 96. It is possible that concrete admixtures may meet this specification, although the manufacturers of the admixtures should be consulted. However, if no potential for vapor passage through the slab is desired, a vapor barrier should be used. A vapor barrier, as defined by ACI, is a product with a water transmission rate of 0.00 perms, per square foot per hour when tested in accordance with ASTM E 96. Reinforced membranes having sealed overlaps can meet this requirement. Additionally, ACI (Section 4.1.5) recommends that a minimum of 4 inches of compactable granular fill, such as crushed rock, should be placed over the vapor retarder or barrier for protection. Sand is not recommended by ACI for use as the protection layer. GEOTECH CONSULTANTS, INC. R&P Investment Co., LLC. clo CDA Architects JN 01248 August 20, 2001 Page 8 Isolation joints should be provided where the slabs intersect columns and walls. Control and expansion joints should also be used to control cracking from expansion and contraction. Saw cuts or preformed strip joints used to control shrinkage cracking should extend through the upper one- fourth of the slab. The spacing of control or expansion joints depends on the slab shape and the amount of steel placed in it. Reducing the water -to -cement ratio of the concrete and curing the concrete, by preventing the evaporation of free water until cement hydration occurs, will also reduce shrinkage cracking. We recommend proof -rolling slab areas with a heavy truck or a large piece of construction equipment prior to slab construction. Any soft ar6as encountered during proof -rolling should be excavated and replaced with select, imported structural fill. ROCKERIES We anticipate that rockeries may be used in the site development. A rockery is not intended to function as an engineered structure to resist lateral earth pressures, as a retaining wall would do. The primary function of a rockery is to cover the exposed, excavated surface and thereby retard the erosion process. We recommend limiting rockeries to a height of 8 feet and placing them against only dense, competent, native soil. The construction of rockeries is, to a large extent, an art not entirely controllable by engineering methods and standards. It is imperative that rockeries, if used, are constructed with care and in a proper manner by an experienced contractor with proven ability in rockery construction. The rockeries should be constructed with hard, sound, durable rock in accordance with accepted local practice. Soft rock, or rock with a significant number of fractures or inclusions, should not be used, in order to limit the amount of maintenance and repair needed over time. Provisions for maintenance, such as access to the rockery, should be considered in the design. In general, we recommend that rockeries have a minimum dimension of one-third the height of the slope cut above them. Tiered rockeries are not recommended, unless there is sufficient space to construct upper tiers that do not exert lateral pressure on the lower tiers. The base of a tiered rockery's upper wall should be set back from the rear of the lower rocks an amount equal to the height of the lower tiers. EXCA VA TIONS AND SLOPES Excavation slopes should not exceed the limits specified in local, state, and national government safety regulations. Temporary cuts to a depth of about 4 feet may be attempted vertically in unsaturated soil, if there are no indications of slope instability. However, vertical cuts should not be made near property boundaries, or existing utilities and structures. Based upon Washington Administrative Code (WAC) 296, Part N, the soil at the subject site would generally be classified as Type B. Therefore, temporary cut slopes greater than 4 feet in height cannot be excavated at an inclination steeper than 1:1 (Horizontal:Vertical), extending continuously between the top and the bottom of a cut. The very dense glacial till soils could be excavated more steeply, but based on proposed excavation depths, these soils will not be encountered in the anticipated cut slopes. The above-recom mended temporary slope inclination is based on what has been successful at other sites with similar soil conditions. Temporary cuts are those that will remain unsupported for a relatively short duration to allow for the construction of foundations, retaining walls, or utilities. Temporary cut slopes should be protected with plastic sheeting during wet weather. The cut slopes GEOTECH CONSULTANTS, INC. R&P Investment Co., LLC. c/b CDA Architects JN 01248 August 20, 2001 Page 9 should also be backfilled or retained as soon as possible to reduce the potential for instability. Please note that loose soil can cave suddenly and without warning. Excavation, foundation, and utility contractors should be made especially aware of this potential danger. All permanent cuts into native soil should be inclined no steeper than 2:1 (H:V). DRAINAGE CONSIDERATIONS Foundation drains should be installed at the base of all footings where the slab or floor is below the outside grade. Drains should also be placed at the base of all earth -retaining walls. These drains should be surrounded by at least 6 inches of 1-inch-minus, washed rock and then wrapped'in non- woven, geotextile filter fabric (Mirafi 140N, Supac 4NP, or similar material). At its highest point, a perforated pipe invert should be at least 6 inches below the bottom of a slab floor or the level of a crawl space, and it should be sloped for drainage. All roof and surface water drains must be kept separate from the foundation drain system. A typical drain detail is attached to this report as Plate 7. For the best long-term performance, perforated PVC pipe is recommended for all subsurface drains. Drainage inside the building's footprint should also be provided where an excavation encounters significant seepage. In general, an outlet drain is recommended for all crawl spaces to prevent a build up of any water that may bypass the footing drains. We can provide recommendations for interior drains, should they become necessary, during excavation and foundation construction. Groundwater was observed during our field work. If seepage is encountered in an excavation, it should be drained from the site by directing it through drainage ditches, perforated pipe, or French drains, or by pumping it from sumps interconnected by shallow connector trenches at the bottom of the excavation. The excavation and site should be graded so that surface water is directed off the site and away from the tops of slopes. Water should not be allowed to stand in any area where foundations, slabs, or pavements are to be constructed. Final site grading in areas adjacent to the buildings should slope away at least 2 percent, except where the area is paved. Surface drains should be provided where necessary to prevent ponding of water behind foundation or retaining walls. PAVEMENTAREAS The pavement section may be supported on competent, native soil or on structural fill placed above competent native soils. Because the site soils are silty and moisture sensitive, we recommend that the pavement subgrade be in a stable, non -yielding condition at the time of paving. Additional granular structural fill or geotextile fabric may be needed to stabilize soft, wet, or unstable areas. To evaluate pavement subgrade strength, we recommend that a proof -roll be completed with a loaded dump truck immediately before paving. In most instances where unstable subgrade conditions are encountered, an additional 12 inches of granular structural fill will stabilize the subgrade, except * for very soft areas where additional fill could be required. The subgrade should be evaluated by Geotech Consultants, Inc., after the site is stripped and cut to grade. Recommendations for the compaction of structural fill beneath pavements are given in the section entitled GENERAL EARTHWORK AND STRUCTURAL FILL. The performance of site pavements is directly related to the strength and stability of the underlying subgrade. GEOTECH CONSULTANTS, INC. R&P Investment Co., LLC. c/o CDA Architects JN 01248 August 20, 2001 Page 10 The pavement for lightly loaded traffic and parking areas should consist of 2 inches of asphalt concrete (AC) over 4 inches of crushed rock base (CRB) or 3 inches of asphalt -treated base (ATB). We recommend providing heavily loaded areas with 3 inches of AC over 6 inches of CRB or 4 inches of ATB. Heavily loaded areas are typically main driveways, dumpster sites, or areas with truck traffic. Water from planter areas and other sources should not be allowed to infiltrate into the pavement subgrade. The pavement section recommendations and guidelines presented in this report are based on our experience in the area and on what has been successful in similar situations. We can provide recommendations based on expected traffic loads and California Bearing Ration (CBR) value tests, if requested. As with any pavements, some maintenance and repair of limited areas can be expected as the pavement ages. To provide for a design without the need for any repair would be uneconomical. GENERAL EARTHWORK AND STRUCTURAL FILL All building and pavement areas should be stripped of surface vegetation, topsoil, organic soil, and other deleterious material. It is important that existing foundations be removed before site development. The stripped or removed materials should not be mixed with any materials to be used as structural fill, but they could be used in non-structural areas, such as landscape beds. Structural fill is defined as any fill, including utility backfill, placed under, or close to, a building, behind permanent retaining or foundation walls, or in other areas where th6 underlying soil needs to support loads. All structural fill should be placed in horizontal lifts with a moisture content at, or near, the optimum moisture content. The optimum moisture content is that moisture content that results in the greatest compacted dry density. The moisture content of fill is very important and must be closely controlled during the filling and compaction process. As discussed in the GENERAL section, the reuse of the on -site soils as structural fill will be challenging in dry weather and not possible in the wet season. This is due to the soils' silty nature and sensitivity to moisture. The allowable thickness of the fill lift will depend on the material type selected, the compaction equipment used, and the number of passes made to compact the lift. The loose lift thickness should not exceed 12 inches. We recommend testing the fill as it is placed. If the fill is not sufficiently compacted, it can be recompacted before another lift is placed. This eliminates the need to remove the fill to achieve the required compaction. The following table presents recommended relative compactions for structural fill: Beneath footings, slabs 95% or walkways I Filled slopes and behind 90% retainina walls I 1 95% for upper 12 inches of Beneath pavements subgrade; 90% below that level Where: Minimum Relative Compaction is the ratio, expressed in percentages, of the compacted dry density to the maximum dry density, as determined in accordance with ASTM Test Designation D 1557-91 (Modified Proctor). GEOTECH CONSULTANTS, INC. R&P Investment Co., LLC. c/o CDA Architects August 20, 2001 Use of On -Site Soil JN 01248 Page 11 The GENERAL section should be reviewed for considerations related to the reuse of on -site soils. If grading activities take place during wet weather, or when the silty, on -site soil is wet, site preparation costs may be higher because of delays due to rain and the potential need to import granular fill. The on -site soil is generally silty and therefore moisture sensitive. Grading operations will be difficult during wet weather, or when the moisture content of this soil exceeds the optimum moisture content. Moisture -sensitive soil may also be susceptible to excessive softening and "pumping" from construction equipment, or even foot traffic, when the moisture content is greater than the optimum moisture content. It may be beneficial to protect subgrades with a layer of imported sand or crushed rock to limit disturbance from traffic. Structural fill that will be placed in wet weather should consist of a coarse, granular soil with a silt or clay content of no more than 5 percent. The percentage of particles passing the No. 200 sieve should be measured from that portion of soil passing the three -quarter -inch sieve. LIMITATIONS The analyses, conclusions, and recommendations contained in this report are based on site conditions as they existed at the time of our exploration and assume that the soil and groundwater conditions encountered in the test pits are representative of subsurface conditions on the site. If the subsurface conditions encountered during construction are significantly different from those observed in our explorations, we should be advised at once so that we can review these conditions and reconsider our recommendations where necessary. Unanticipated soil conditions are commonly encountered on construction sites and cannot be fully anticipated by merely taking soil samples in test pits. Subsurface conditions can also vary between exploration locations. Such unexpected conditions frequently require making additional expenditures to attain a properly constructed project. It is recommended that the owner consider providing a contingency fund to accommodate such potential extra costs and risks. This is a standard recommendation for all projects. This report has been prepared for the exclusive use of R&P Investment Co., LLC, CDA Architects, and their representatives, for specific application to this project and site. Our recommendations and conclusions are based on observed site materials, and engineering analyses. Our conclusions and recommendations are professional opinions derived in accordance with current standards of practice wit ' hin the scope of our services and within budget and time constraints. No warranty is expressed or implied. The scope of our services does not include services related to construction safety precautions, and our recommendations are not intended to direct the contractor's methods, techniques, sequences, or procedures, except as specifically described in our report for consideration in design. ADDITIONAL SERVICES GEOTECH CONSULTANTS, INC. R&P Investment Co., LLC. c/o CDA Architects August 20, 2001 JN 01248 Page 12 that subsurface conditions are consistent with those indicated by our exploration, to evaluate whether earthwork and foundation construction activities comply with the general intent of the recommendations presented in this report, and to provide suggestions for design changes in the event subsurface conditions differ from those anticipated prior to the start of construction. However, our work would not include the supervision or direction of the actual work of the contractor and its employees or agents. Also, job and site safety, and dimensional measurements, will be the responsibility of the contractor. The scope of our work did not include an environmental assessment, but we can provide this service, if requested. The following plates are attached to complete this report: Plate 1 Vicinity Map Plate 2 Site Exploration Plan Plates 3 - 6 Test Pit Logs Plate 7 Typical Footing Drain We appreciate the opportunity to be of service on this project. If you have any questions, or if we may be of further service, please do not hesitate to contact us. SES/JHS: esm Respecffully submitted, GEOTECH CONSULTANTS, INC. Scott Stevens Geotechnical Engineer �-,S-VON S WAS A 5i S6 q . 4 'Tivi!7110 "�' � 'A - OP/0 V 1EXPIRES 01-31- 0 7— James H. Strange, Jr. P.E. Senior Geotechnical Engineer GEOTECH CONSULTANTS, INC. KINGSTON v GEOTECH CONSULTANIS, INC. VICINITY MAP 236xx - 84th Avenue West Edmonds, Washington Job IVO. Date.. Scale. Rate. 01248 Aug 2001 Not to Scale BLDG 998"\ BLM,13— am M w 'n z w F- V 00 236TH STREET SOUTHWEST 1000, i TP-8t. TP-71 r4 994' "TP-1 N EXISTING BUILDING LEGEND ErAPPROXIMATE TEST PIT LOCATIONS 238TH STREET SOUTHWEST GEOTECH CONSUILTAN-M INC. SITE EXPLORATION PLAN 236xx - 84th Avenue West Edmonds, Washington Job Mo. Seale. plate. 27 01248 Dateg. 2001 1 Not to Scale I TEST PIT 1 O� 11 4�0 CP Description L I I I Brown organic FILL, loose Brownish gray silty SAND, fine grained, moist, loose 5 11;�111!1! -becomes gray silty SAND w/trace gravel, fine to medium -grained, moist, medium sm dense -becomes glacially consolidated, dense glacial till ij 10- 15L * Test Pit was terminated at 9 feet on July 31, 2001.. • Groundwater seepage was observed at 7 feet during excavation. • No caving was observed during excavation. 5 10 15 1'� TEST PIT 2 '.' 0 e, 0; "'g, cll� 1� 0, ';�� Description Black organic topsoil, moist, loose Brownish gray silty SAND, fine-grained, moist, loose Gray silty SAND with gravel, fine to medium -grained, moist, medium -dense -becomes dense (glacial till) • Test Pit was terminated at 10 feet on July 30, 2001. • No groundwater seepage was observed during excavation. • No caving was observed during excavation. GEOTECH CONSULTANTS, INC. TEST PIT LOG 236XX - 84th Avenue West Edmonds, Washington Job No: Date: Logged by: Plate: 01248 July 2001 1 SES 1 3 TEST PIT 3 5 10 15 0 C, 4�'O ')CP e, Description Brownish gray silty SAND, fine-grained, moist, loose -becomes gray silty SAND w/gravel, fine to medium -grained, medium -dense • Test Pit was terminated at 5 feet on July 31, 2001. • No groundwater seepage was observed during excavation. • No caving was observed during excavation. TEST PIT 4 Description Topj lopso Brownish gray silty SAND, fine-grained, moist, loose I _T 1111 SM with trace gravel, medium -dense 6 �_ I 10 15 -becomes fine to medium -grained, wet -becomes gray gravelly silty SAND, dense (glacial til • Test Pit was terminated at 9 feet on July 31, 2001. • No groundwater seepage was observed at 5 feet during excavation. • No caving was observed during excavation. GEOTECH CONSULTANTS, INC. TEST PIT LOG 236XX - 84th Avenue West Edmonds, Washington Job No: Date: Logged by: Plate: 01248 July 2001 SES 1 4 10 TEST PIT 5 CP Description Brown/ black organic silty SAND/ sandy silt FILL, moist, loose old tree found Brownish gray, silty SAND, fine-grained, moist, medium -dense -becomes gray, gravelly, silty, sandy, fine -to medium -grained, moist, dense (glacial till) 15 r Test Pit was terminated at 12 feet on July 31, 2001. No groundwater seepage was observed during excavation. No caving was observed during excavation. 5 10 15 TEST PIT 6 Description FILL Black wl concrete FILL. � I Brownish gray, silty SAND, fine-grained, moist, loose. s -becomes gray, gravelly, silty, sandy, fine -to medium -grained, moist, dense 'glacial till, SAND, dense, very moist • Test Pit was terminated at 8 feet on July 31, 2001. • No groundwater seepage was observed during excavation. • No caving was observed during excavation. • STRONG petroleum odor from Vto 8'. • Discoloration in soil from Vto 8'. GEOTECH CONSULTANTS, INC. I TEST PIT LOG 236XX - 84th Avenue West Edmonds, Washington Job No: Date: Logged by. Plate: 01248 July 2001 SES TEST PIT 7 CP FILL FILLI Concrete rubble Description 5 R! Brownish gray, silty SAND, fine-grained, moist, loose -becomes fine -to medium -grained; with trace gravel, medium -dense li -becomes glacially consolidated, dense (glacial till) 10 16r Test Pit was terminated at 10 feet on July 31, 2001. No groundwater seepage was observed during excavation. No caving was observed during excavation. e, �G'� In e 0 CP TEST PIT 8 Description S0111 I opsoll Brownish gray, silty SAND, fine-grained, moist, loose becomes fine -to medium -grained with trace gravel, medium -dense sm � I -becomes glacially consolidated (glacial till) 5 L_ 111 10 15 • Test Pit was terminated at 6 feet on July 31, 2001. • No groundwater seepage was observed during excavation. • No caving was observed during excavation. GEOTECH CONSULTANTS, INC. TEST PIT LOG 236XX - 84th Avenue West Edmonds, Washington Job No: Date: Logged by. Plate: 01248 July 2001 1 SES 1 6 Slope backfill away from foundation. Provide surface drains where necessary. 6" min. Tightline Roof Drain (Do not connect to footing drain) Backfill (See text for requirements) Vapor Retarder or Barrier Nonwoven Geotextile Filter Fabric .............. ......... SLAB ........... ........... ............... 0 0 0 ................ 0 �0 0�0�p� ...... C) o --- Free -Draining Gravel 4" Perforated Hard PVC Pipe (if appropriate) (Invert at least 6 inches below slab or crawl space. Slope to drain to appropriate ouffall. Place holes downward.) NOTES: (1) In crawl spaces, provide an outlet drain to prevent buildup of water that bypasses the perimeter footing drains. (2) Refer to report text for additional drainage and waterproofing considerations. GEOTECH CONSULTANTS, INC- FOOTING DRAIN DETAIL 236xx - 84th Avenue West Edmonds, Washington Job NO. 0 124 8 Dateg 2 0 01 1 SNcaolteto S ca I e I plate' 7 ad ty r Liz& ERMIT EXPIF . 4ES f USE PERMIT EDMONDS ZON NUIS i � 4 % E Nw S'.ITE/APT# CONSTRUPTI" &6T APPLICATION =D RgV­ Z�t OWNER NAME/NAME OF.JV�SlNESS 2M& N . I A PLAT NAME/SUBDIVISI ON NO. LOT NO. LID NO. OJWW ir MAILING ADDRESS LID FEE $ :W fi TESCIP Apprme PUBLIC RIGHT OF WAY PER OFFICIAL ST EET MAP Rw Permit Requdr d 0 Z street use Pormit'RI'd t�OK EXISTING Inspection Re uired ZIP PROPOSED 4 TELEPHONE sidewalk Required *1 REQUIRED DEDICATION FT Und'arground ­g Y�R EOUIREP NO 0 3 10�2 'S NAME L-T H 4k METER SIZE LINE SIZIf r NO. OF FIXTURES -7-- i z DDRESS 5541 REMARKS Le OWNER/CONTRACTOR RESPONSIBLE FOR EROSION CONTROUORAINAGE .M CITY a, ZIP TELEPHONE ,5L1xM'U-1 �OLS, (Dowsai N),n,*+W* NAME C/6 4, ED1~49 ENGINEERING 41S- y CC ADDRESS ) 1&9 lb" 7,' JTEL`EPHONE REVIEWED BY DATE Lu CITY zip ;, CC z 7_ 0 % . 9F d6_9- VARIANCE OR CU SHORELINE INSPECTION BOND 8TATt LICENSE NUMBER'' EXPI19ATION DATE CI�AKED BY REO'D POSTED ES C) NO 14IS14 mez SEPA REVIEW SIGN AREA HEIGHT _j LL, ., PROPERTY TAX AC bpNT PARCEL NO. COMPLETE EXEMPT ALLOWED PROPOSED FALLOWED PROPOSED LU EXP Kt5 LOT COVERAGE REQUIRED SETBACKS (FT.) PROPOSED SETBACKS (FT.) NEW RESIDENTIAL PLUMBING / MEC-H%i,. ALLOWED PROPOSED FRONT SIDE REAR FRONT L/RSIDE REAR COMPLIANCE OR -4 .- - z E] AUDITION r. E] COMMERCIAL 10 15 /L5 Va z CHANGE OF USE PARKING LOT AREA PLANNI 0 TE 7 � �/ !WEVIEWED BY REMODEL APARTMENT F-1 SIGN RgP'D' PROVIDED -M CYDS FENZC if X . REPAIR &tJ DEMOLISH TAJWRL-__� o OTHER fe- J;ct4t) GARAGE AETAINING WALL .0 CARPORT RENEWAL ROCKERY h P '-'�LTYPE OF USEB SINESS 6R.AbTIVITY) EXPLAIN: D Y C ECKE B CQNSTRUCTION CODrif. - OCQVPANT Lk (;7r A ljv, '�4z! kv] . 4�17 'GROUP NUMBER-TUO -f- 4NWUMBLE'R OF RITICAL yof D EL N. I? A OF �C REAS SPECIAL INSPE&OR AREA OCCUPANT STORIES UZ)" UNITS NUMBER REQUIRED YES go LOAD DESCRIBE WORK TO. BE DONE I n(o REMARKS PROGRESS INSPECTIONS PER ILIBC 108/FINAL INSPECTION RE CC "cr L JAI IT'W _j key I�PA_ M mr.1 - I , -M-C, ATIL �1 LT-t- wo kl- 501'1 '11� 11*165 k, 1��m,47 J I ti_2i VALUATION FEE' 9� PLAN CHECK FEE HEAT SOURCE GLAZING % t (, "T L C BpILDINIG -,2,(74 " ' PLAN CHECK bjO; �StEFDA PLUMBING �21 31!;20 THIS PERMIT AUTHORIZES ON ;,THIS PERMIT COVEA�VORK TO t: BE DONE ON PRIVATE PROPERTY ONLY. A 'N q %Y,,Cj& SZ,,CTION 014 THE PUBLIC S 1 2 DOMAIN (CURBS, SIDEWALKS, DRIVEWA Sid' d S, ETC.) WILL REQUIRE GRADING/FILL _741 :1 SEPARATE PERMISSION. --- StATE SURCHARGE .15' PERMIT APPLICATION: 180 DAYS Lu PERMIT 6MIT: I YEAR - PROVIDED WORK!IS STARTED WITHIN 180 DAYS ENG. REVIEW FEES SEE BACK OF PINK PERMIT FOR MORE INFORMATION *APPLICANT, ON BEHALF OF HIS OR HER SPOUSE, HEIRS, ASSIGNS AND SUCCESORS ENG. INSPECTION FEE W I ., N INTEREST, AGREES TO INDEMNIFY. DEFEND AND HOLD HARMLESS THE CITY OF LANDSCAPING 2 EDMONDS, WASHINGTON, ITS OFFICIALS. EMPLOYEES. AND AGENTS FROM A�YIAND INSPECTION FEE ALLCLAIMSF R DAMAGES OF WHATEVER NATURE, ARISING DIRECTLY OR INDIRECTLY x FROM THE ISSUANCE OF THIS PERMIT. ISSUANCE OF THIS PERMIT SHALL N& BE RECE 0 D PLAN CHECK DEPOSIT A EEMED TO MODIFY, WAIVE OR REDUCE ANY REQUIREMENT OF ANY CITY ORDINANCE 7c;r/477 416W 0 NOR LIMIT IN ANY WAYTHE CITY'S ABILITY TO ENFORCE ANY ORDINANCE PROVISION.- x �; _ _t�� � ., TOTAL AMOUNT DUE. / !z j vi C� T5-. I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION; THAT THE INFORMATION GIVEN IS CORRECT:AND THAT I AM THE OWNER. OR THE DULY AUTHORIZED AGENT OF APPLICATION APPROVAL THE OWNER. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUC- This application is not a permit until signed by the TION; AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED CALL Building Official or his/her Deputy: � n-d Fees are paid. and IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO FOR INSPECTION receipt is acknowledged in space provided. WORKMEN'S COMPENSATION�ANCE'AND RCW 18-27. OF IALS AT DATE NATURE (OWNE DATEtIGNED (425) 'PIG 771-0220 LE: R1rL ASED BY IfATE ATTENTI ON I EXT 1333 IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL 771-0221 A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFI- CATE OF OCCUPANCY HAS BEEN GRANTED. UBC SECTION 1Q9 ORIGINAL - FILE YF- n - *INSPE�TOR x FAX PINK - OWNER - GOLD - ASSESSOR 5/98 MMIVTE -RECEIYSED) PERMIT EXPIRES USE PERMIT ITY OF EDMONDS 111E NUMBERcWX CONSTRUCTION PERMIT APPLICATION 'qOB SUITE/APT# ADDR�V. /9 I 01�LNER NAME/NAMWF BUSINESS I Lqj MAILING ADDRES ZI 0147" kqt ','_-xAme ZIP TELEPHONE syc_ Kn-Lv n ?-I I ".� � .,1. 1660 JCIT4-i ADDRESS :5,541 Zj r, 6. ? r,-T M I ISL. NAME ADDRESS CITY 5,et�;W_7204:5 STATE LICENSE NUMBER A�-C PLAT NAME/tUBDIVI SION NQ. LOT NO. LIDNO�Owsv LID FEE $ PUBLIC RIGH * T OF WAY PER OFFICIAL STREET MAP TESCID Aporoved RW Permit Required. 1A Street Use Pemk Req'd EXISTING SED PROPO action Required Sidewalk Required REQUIRED DEDICATION FT Underground WUft required METER SIZE LINE SIZE I NO. OF FIXTURES PRV REQUIRED REMARKS 115Z� WNERICONTRACTOR RESPONSIBLE FOR ZIP TELEPHONE ZIP 25V - 55'�) 4 EXPIRATION DATE I CHECI(ED BY PROPERTY TAX ACCOUNT PARCEL NO 5 NEW RESIDENTIAL PLUMBING MECH C ADDITION 0 COMMERCIAL COMPLIANCE OR CHANGE OF USE 0 REMODEL APARTMENT C] SIGN GRADING CYDS c3 FENCE X 0 REPAIR FT: DEMOLISH 0 TANK OTHER 0 GARAGE RETAINING WALL CARPORT ROCKEDY 0 RENEWAL E 0. g OF USE, BUSINESS OR ACTIVITY) rPLAIN: E — L) I.. H LAi,-n - AHJLV M NUMBEFr�14D t NUMBER OF 1FCRITICALWr-fr -4—mr-e a OF DWELLING AREAS �_Oe 1� M0 STORIES UNITS 'NUMBER ,�044� DESCRIBE WORK TO BE DONE ENGINEERING YES)( NO 13 z DRAINAGE. FIRE REVIEWED BY DATE 0 VARIANCE OR CU SHORELINE OF�A!Rq" INSPECTION I*J� /REO'D PBOND 0 D Wlny &YES 0 NO SEPA REVIEW SIGN AREA HEIGHT COMPLETE EXEMPT ALLOWED I PROPOSED ALLQWED PROPOSED EXP �<l t5,t5 I Z!5-,r5- LOT COVERAGE REQUIRED SETBACKS (FT.) PROPOSED SETBACKS (FT.) ALLOWED PROPOSED 45- to FRONT SIDE REAR NT L/A A 15 /0 z z PARKING LOT AREA PLANNING REVIE'A Ed'BY D#TE REQ'D PYRV 0 ED V 1b116U61`b_Do4'_ /.,-1 6 z, FV111- PDft 13L-D(, A f-v IL f- I'D 0 4.4. t-Pr WECKEDBY ITYFIL TION I CO :)CCUPANT ONSTRUgi 4Af up 2 17 OGRO SPECIAL INVCTOR AREA OCCUPANT S LOAD '9 1 YREQUIRED YES Vt I 0(1�1 . 1 51 REMARKS PROGRESS INSPECTIONS PER UBC 10111FINAL INSPECTION "CT > L 1% C �kn2caft �6c_i-AT­L-o lk)oaw, 1<1 // 0 R" MUIR LP I WF M.- HEAT SOUR!�:tf *%I�L < fr5LOPE% J5 LC 0170 PLAN CH? 0- VESTED DATE 7-C * &" . THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE D SEPARATE PERMISSION. PERMIT APPLICATION; 180 DAYS a. PERMIT LIMIT- I YEAR - PROVIDED gORK IS STARTED WITHIN 180 DAYS SEE BACK OF PINK PERM FOR MORE INFORMATION 'APPLICANT. ON BEHALF OF HIS OR HER SPOUSE. HEIRS, ASSIGNS AND SUCCESORS IN INTEREST, AGREES TO INDEMNIFY. DEFEND AND HOLD HARMLESS THE CITY OF 2 EDMONDS, WASHINGTON, ITS OFFICIALS, EMPLOYEES, AND AGENTS FROM ANY AND ALL CLAIMS FOR DAMAGES OF WHATEVER NATURE, ARISING DIRECTLY OR INDIRECTLY X, FROM THE ISSUANCE OF THIS PERMIT. ISSUANCE OF THIS PERMIT SHALL NOT BE 0 i DEEMED TO MODIFY, WAIVE OR REDUCE ANY REQUIREMENT OF ANY CITY ORDINANCE 0 NOR LIMIT IN ANY WAY THE CITY'S ABILITY TO ENFORCE ANY ORDINANCE PROVISION." I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION; THAT THE INFORMATION GIVEN IS CORRECT, AND THAT I AM THE OWNER, OR THE DULY AUTHORIZED AGENT OF THE OWNER. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUC- TION; AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. S IS;; i &RE (OWNER DATE 7GNED e? 101 ATTENTION IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFI- CATE OF OCCUPANCY HAS BEEN GRANTED. UBC SECTION 109 5/98 VALUATION PLAN CHECK FEE BUILDING PLUMBING MECHANICAL GRADIN C&"!5—/ - r STATE SURCHARGE ENG. REVIEW FEES ENG. INSPECTION FEE LANDSCAPING PLAN CHECK DEPOSIT TOTAL AMOUNT DUE I RECMAa)67 1 -7 :�IAI -=.!S- APPLICATION APPROVAL CALL This application is not a permit until signed by the FOR INSPECTION Building Official or his/her Deputy: and Foes are paid. and receipI is acknowledged in space provided. (425) AL 070�14A&T DATE U 4�� A�� 771-0220 f4ELFA'SE D_ BY DATE EXT 1333 ri 771-0221 FAX ORIGINAL -FILE YELLOW/INSPEQ�OR PINK -OWNER GOLD -ASSESSOR ATE RECEIVED c CITY OF EDMONDS CONSTRUCTION PERMIT APPLICATION I OWREB NAME/NAME OF BUSINESS W MAIL NG ADDRESS Lu I z 2to I Gay ,5L- Mu NST4t ADDRESS t6 556 _X, A-TLV L NAME ESS v zip, TELEPHONE 'd I z 2 ao .� -I Coe) Aa 1-75M ZIP TELEPHONE "J'n- 155 1 2a . 9 CITY - / zip -d:Z!J`/4&GE QCIAV STATE LICENSE NUMBER EXPIRATION DATE I CHECKED BY PROPERTY TAX ACCOUNT PARCEL NO. -Cf//7 NEW RESIDENTIAL PLUMBING / MECH C] ADDITION COMMERCIAL COMPLIANCE OR CHANGE OF USE REMODEL APARTMENT 0 SIGN REPAIR GRADING CYDS FENCE X ( _ FT) 0 DEMOLISH 0 TANK OTHER oGARAGE CARPORT HETAINING WALL I , , i ROCKERY 0 RENEWAL (�KE OF USE, BUSINESS OR ACTIVITY) EXPLAIN: I ± ("n P-A H I , NUMBER Wv44C.#-tr7A—YMBER OF 6�6 C R 11 T I CA L AtV a USE ZONE PERMIT EXPIRES PERMIT A A SUITE/APT# oo, ADDRESS 44 PLAT NAME/SUBDIVI SION NO. LOT NO. LID NO: aj ; (45 i LID FEE $ PUBLIC RIGHT OF WAY PER OFFICIAL STREET MAP TESCP 4proved RW Pernift =ad Street Vve Roq*d' EXISTING - PROPOSED InWection Required Sidewalk Required REQUIRED DEDICATION- FT underground Wift required METER SIZE I LINE SIZE I NO. OF'FIXTURES P V - EQUIRED onREMARKS OWNER/CONTRACTOR RESPONSIBLE FOR EROSION C( ENGINEERING YES OK NO 0 z DRAINAGE 0 z W FIRE REVIEWED BY DATE cy- —(3 7 X V-1—NICE OR CU SHORELINE 0,7498 INSPECTION I BOND REO'D P9 ES b NO VO Xy SEPA REVIEW SION AREA HEIGHT COMPLETE I EXEMPT ALLOWED PROPOSED ALLOWED , PROPOSEI? EXP LOT COVERAGE REQUIRED SETBACKS (FT) PROPOSED SETBACKS (FT.) ALLOWED PROPOSED FRONT SIDE REAR FRONT R SIDE REAR 45' lo 15' /0 . 15" 1 z PARKING LOT AREA PLANNING REVIEWED BY ' DATE ,F&9'D PROIfIDED I 16 1 T6 17 7 K I �, -Emwa- d i An, t 504T) AM 00 04'r BY jTyt"F,CONSTRUCj�ON I C 09 ra L — 10 = Molt T 0 F DWELLING AREAS SPE TOR AREA STORIES fiIA1 U NUMBER Z, RE UIRED YES - DESCRIBE WORK TO BE D ONE 1 RPEMA.FRIKS .0 4 PROGRESS INSPECTIONS PER UBC 108/FINAL I A`54S6;r_I ATL- A, 45 t r(5' =3- GLAZING % §�OPE Z. . 4; <, If 76 VALUATION PLAN CHECK FEE BUILDING -7 PLAN CHECV, NO: � ,,> /) VESTED DATE PLUMBING 4,dp — 70- 4"(7 t MECHANICAL THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO t: BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC 2 DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE GRADING/F 1051-1 :3 SEPARATE PERMISSION. STATE SURCHARGE Uj PERMIT APPLICATION: 180 DAYS PERMIT LIMIT: I YEAR - PROVIDED WORK IS STARTED WITHIN 180 DAYS ENG. REVIEW FEES SEE BACK OF PINK PERMIT FOR MORE INFORMATION 'APPLICANT, ON BEHALF OF HIS OR HER SPOUSE. HEIRS, ASSIGNS AND SUCCESORS ENG. INSPECTION FEE Lu IN INTEREST, AGREES TO INDEMNIFY. DEFEND AND HOLD HARMLESS THE CITY OF _j 2 Ma EDMONDS, WASHINGTON, ITS OFFICIALS, EMPLOYEES, AND AGENTS FROM MINT ANU ANDSCAPING :NSPECTION FEE ALL CLAIMS FOR DAMAGES OF WHATEVER NATURE, ARISING DIRECTLY OR INDIRECTLY x FROM THE ISSUANCE OF THIS PERMIT. ISSUANCE OF THIS PERMIT SHALL NOT BE PLAN CHECK DEPOSIT RECE7F DEEMEDTO MODIFY, WAIVE OR REDUCE ANY REQUIREMENTOF ANYCITY ORDINANCE 0 NOR LIMIT IN ANY WAYTHE CITY'SABILITY TO ENFORCE ANY ORDINANCE PROVISION.' TOTAL AMOUNT DUE -Pzl'7 540 I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION: THAT THE INFORMATION GIVEN IS CORRECT. AND THAT I AM THE OWNER, OR THE- DULY AUTHORIZED AGENT OF APPLICATION APPROVAL THEOWNER. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUC- CALL This application is not a permit until signed by the TION; AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED Building Official or his/her Deputy: and Fees are paid. and IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO FOR INSPECTION receipt is acknowledged in space provided. WORKMEN'S COMPENSATION.INSURANCE AND RCW 18.27. IGAVLZRIE (OWNE DATE GNIED 1 (425) OF kL ATU R DATE 771-0220 4AEASED BY /DATE ATTENTION EXT 1-333 IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL 771-0221 V_�944� - �2w A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFI_ - - CATE OF OCCUPANCY HAS BEEN GRANTED. UBC SECTION 109 FAX ORIGINAL-FILF YFII(4-INSP OR PINK 5/98 -OWNER GOLD -ASSESSOR 1,41 /jj�j' RECEIVED PERMIT EXPIRES CITY OF EDMONDS tCONSTRUCTION tI US E ZON PERMIT NUMBERC2M PERMIT APPLICATION JOB T# ADDRESS, 01 SLITE/A - A 7 gv�� zv,7 OWNER NAME/NAME OF BUSINESS -�)IA#,j TI'JIA PLAT NAME/tUBI)IVI SION NO. LOT NO. LID NO. CV (4 w M z 3: 0 MAILING ADDRESS V rru, Z,,�>o PUBLIC RIGHT OF WAY PER OFFICIAL STREET MAP EXISTING — PROPOSED REQUIRED DEDICATION— FT 'TE6CP AFOroved 0 RW Pennit Required Street Vae Permit Req'd Inspectle, Required SidewalknRequIred Underground Wiring required CITY ZIP "'�Li AT -a I I TELEPHONE I I Z04­1� i, 16-j6 NAMME. �H� HALF METER SIZE LINE SIZE I NO. OF FIXTURES -22 PRV REQUIRED YESON NO 0 E 2 ADDRESS n5z-1 �Atu �xc- (- " � REMARKS OWNER/CONTRACTOR RESPONSIBLE FOR EROSION CQNTRQUDRAINAGE CITY ZIP TELEPHONE NAME 7,3 MA77A M 2 4 CC ENGINEERING REVIWED/DATE -- ADDRESS zgz�z A�z--k 412" FIRE REVIEWED BY DATE �s I`- z 0 CITY ZIP TELEPHONE STATE LICENSE NUMBER EXPIRATION DATE Cf:WCKED BY VARIANCE OR CU SHORELINE 0 ADB INSPECTION REO'D 0 NO BOND SEPA REVIEW COMPLETE I EXEMPT EXP PC SIGN AREA ALLOWED PROPOSED] .136ES HEIGHT ALLOWED PROPOSED 4 Lu0 44 PROPERTY TAX ACCOUNT PARCEL NO. CI -Ck015 ISM 60 1 1.1's 0 -(Doi - 6a 0,50 7, NEW C] RESIDENTIAL PLUMBING I MECH 0 ADDITION COMMERCIAL o COMPLIANCE OR CHANGE OF USE F1 REMODEL L APARTMENT C3 SIGN REPAIR GRADING o FENCE CYDS X FT) LOT COVERAGE ALLOWED PROPOSED REOUI RED SETBACKS (FT.) FRONT SIDE REAR I 15- /D 1.5 PROPOSED SETBACKS (FT.) FRONT LIRSIDE REAR 10f NA z z PARKING ED LOT AREA Ire PLANNING Rpvi;:WF:n By DAT //7 /0Z, REMARKS P DEMOLISH C3 TANK C3 OTHER GARAGE RETAINING WALL RENEWAL CARPORT ROCKERY -r6lmr- foxc &,DI, (LE OF USE. BUSINESS OR ACTIVITY) PLAI AIQ KEDBY ITYP OFCONSTRU�ON COQL =C GFIOPPANT UP �e g, o NUMBERTttcrt NUMBER OF CRITICAL OF DWELLING AREAS UNITS NUMBE t� 71 STORIESN5L If R IV, SPECIAL INS, P;CTOR JAREA REQUIRED & YES n— OCCUPANT LOAD ' 9!�* DESCRIBE WORK TO BE DONE REMARKS PROGRESS INSPECTIONS PER UBC 108/FINAL INSPE CTION REG'D R6 L'�, W JAYflw 4V 'S M2 IAV� �Vr 1 -z-45- -e,711911161 VALUATION FEE i,q� PLAN CHE'CK FEE 6-j/Z f6P7 HqAT SOURCE GLAZING 9% L aI­OPE % LLC— BUILDING ZA14 '7 70L PLAN CHECK NV: VESTED DATE PLUMBING THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO MECHANICAL BE'DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE GRADINGIFW5L 71�7 0 SEPARATE'PERMISSION. STATE SURCHARGE W PERMIT APPLICATION: 180 DAYS PERMIT LIMIT. I YEAR - PROVIDED WORK IS STARTED WITHIN 180 DAYS ENG. REVIEW FEES SEE BACK OF PINK PERMIT FOR MORE INFORMATION 'APPLICANT, ON BEHALF OF HIS OR HER SPOUSE, HEIRS, ASSIGNS AND SUCCESORS ENG. INSPECTION FEE IN INTEREST. AGREES TO INDEMNIFY, DEFEND AND HOLD HARMLESS THE CITY OF LANDSCAPING 2 EDMONDS, WASHINGTON, ITS OFFICIALS, EMPLOYEES, AND AGENTS FROM ANY AND cc INSPECTION FEE 4 ALL CLAIMS FOR DAMAGES OF WHATEVER NATURE, ARISING DIRECTLY OR INDIRECTLY FROM THE ISSUANCE OF THIS PERMIT. ISSUANCE OF THIS PERMIT SHALL NOT BE DEEMED To MODIFY, WAIVE OR REDUCE ANY REQUIREMENTOF ANYCITY ORDINANCE PLAN CHECK DEPOSIT RECEIPT NOR LIMIT IN ANY WAYTHE CITY'S ABILITY TO ENFORCE ANYORDINANCE PROVISION.' TOTAL AMOUNT DUE I HEREBY ACKNOWLEDGE THAT � HAVE READ THIS APPLICATION; THAT THE INFORMATION GIVEN IS CORRECT. AND THAT AM THE OWNER. OR THE DULY AUTHORIZED AGENT OF ­4 APPLICATION APPROVAL THE OWNER. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUC- CALL This application is not a permit until signed by the TION; AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED u B ilding Official or his/her Deputy: and Fees are paid. and IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO recei FOR INSPECTION_ acknowledged in space provided. WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. Slil:[�MRE (OWN ENT DATE IGNED (425) 0 TURY) DATE 4� Z4 61 771-0220 /R ED B EAA S' 454TE A17ENTION EXT 1333 IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL 771-0221 A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFI- CATE OF OCCUPANCY HAS BEEN GRANTED. UBC SECTION 109 FAX ORIGINAL - FI LE YEl1r%1A1tjN�oc,4­ PINK-OWNER 5/98 GOLD -ASSESSOR &_ 4 CITY OF EDMONDS CONSTRUCTION PERMIT APPLICATION OWNER NAMEINME OF BUSINESS t6� MAILING ADDRESS CITY ZIP ATELEPHONE NAME ADDRESS CITY ZIP TELEPHONi NAME CITY ZIP I TELEPHONE STATE LICENSE NUMBER EXPIRATION DATE I TAX ACCOUNT 0 NEW 0 RESIDENTIAL 0 PLUMBING / MECH 0 ADDITION COMMERCIAL x 0 COMPLIANCE OR CHANG E OF USE 0 REMODEL 0 APARTMENT 0 SIGN 0 REPAIR 0 GRADING FENCE CYOS x 0 DEMOLISH 0 TANK /101 OTHER oGARAGE 0 RETAINING WALL 0 CARPORT ROCKERY RENEWAL ITYPE OF USE. BUIDIESS OR ACTIVITY).,EXPLAIN: NUMBER NUMBER OF OITICAL OF DWELLING AREAS STORIES UNITS NUMBEQLOQ� DESCRIBE WORK TO BE DONE -4 el PERMIT EXPIRES ym I USE ZONE PERMIT NIIJIMBER4q,��g -&4410� JOB ADDRESS SUTIVAPT# xs�&q/ Z�6 !�� PLAT NAMEISUBDIVISION NO. LOT NO. LIO NO. I LID FEE 111 PUBLIC RIGHT OF WAY PER OFFICIAL STREET MAP TESCP APPrand RW Pwffjk Roquhw S"M Us Pwmk Rprrd EXISTING - PROPOSED Vapection Required SkW*a& ReWhO REQUIRED DEDICATION- FT U I wma MUM METER SIZE I LINE SIZE. I NO. OF FIXTURES I PRV REQUIRED YESD No 13 ze REMARKS I OWNER/CONTRACTOR RESPONSIBLE FOR EROSION CONTROL/DRAINAGE rex"46- 7D lrgwAfl:j�'Al ,*j L.11V6_ ENGINEERING FIRE REVIEWED BY DATE By VARIANCE OR CU SHORELINE OR ADS# INSPECTION BOND 7-1 REO'D IC] YES &UO POSTED I SEPA REVIEW SIGN AREA HEIGHT com XEMPT ALLOWED PROPOSED ALLOWED PROPOSED EXP� 1. LOT COVERAGE REQUIRED SETBACKS (Fr.) PROPOSED SET13ACKS (Fr.) ALLOWED PROPOSED FRONT SIDE REAR FRONT URSIDE REAR z PARKING L AREA I PI;ANNING REVIEWED BY PAT I R EOD I PROVIDED IL � _t= — 'a K�'r1__)L1L.L,0C44 1_1� lon FT) I REMARKS CHECKED BY I TYP OF CONSTRUCTION CODE OCCUPANT . . A 1 GROUP 4j 9& SPECIAL INSPECTOR JAREA OCCUPANT REQUIRED 0 Y ES LOAD REMARKS PROGRESS INSPECTIONS PER USC 108/FINAL INSPECTION RECVD VALLIATION $ FEE FEE Plan Check HEAT SOURCE GLAZING% LOT SLOPE % Building PLAN CHECK��/ VESTED DATE Plumbing Mechanical THIS PIE 0 , OMY THE WORK NOTED. THIS PERMIT COVERS WORK TO It BE DOME ON PRIVATE PROPERTY ONLX ANY CONSTRUCTION ON THE PUBLIC 23 DOMAIN (CURBS. SIDEWALKS, DRWEWAVS, MARQUEES, E-rc.) WILL REQUIRE Grading Recording Fee SEPARATE PERMISSION. PERMITAPPLICATION: Engr. Review City Surcharge ISO DAYS IL P . ERMIT UMFP I YEAR - PROVIDED WORK IS STARTED WITHIN 180 DAYS Engr. Inspection State . Surcharge SEE BACK OF PINK PERMIT FOR MORE INFORMATION ;APPU T, ON BEHALF OF HIS OR HER SPOUSE, HEIRS, ASSIGNS AND SUCCESORS Traffic Mitigation Plan Chk Deposit N INT=EST. AGREES TO INDEMNIFY. DEFEND AND HOLD HARMLESS THE CITY OF EDMONDS, WASHINGTON, ITS OFFICIALS, EMPLOYEES, AND AGENTS FROM ANY AND Fire Review Receipt III ALL CLAIMS FOR DAMAGES OF WHATEVER NATURE, ARISING DIRECTLY OR INDIRECTLY FROM THE ISSUANCE�OF THIS PERiArr. ISSUANCE OF THIS PERMIT SHALL NOT BE DEEMED TO MODIFY, WAIVE, OR REDUCE ANY REQUIREMENT OF ANY CITY ORDINANCE Fire Inspection Total Amount Due NOR LIMIT IN ANY WAY THE CITY'S ABILITY TO ENFORCE ANY ORDINANCE PROVISION.' Landscapelnsp., Receipt # I HERE.By ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION; THAT THE INFORMAI ON GIVEN IS CORRECII AND THAT I AM THE OWNER, OR THE DULY AUTHORIZED AGENT OF APPLICATION, APPROVAL THE OWNER. I AGREE,TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUC-. TION; AND IN DOING THE WORK AUTHORIZED THEREBY. NO PERSON WILL BE EMPLOYED CALL This application Is not a permit until signed b y the IN VIOLATION OF THE LA136R CODE OF THE STATE OF WASHINGTON RELATING TO FOR INSPECTION Suldin Official or Wffier Deputy: and roes are paid, and Is acknowledged In space provided. WORKMEWS, COMPENSATION I RANCE AND RCW 18.27. SIGNATUR (OWNER 0 GENT) ODATE SIGN �D .35) (42 OF UR DATE 771-0220 -RELEASED ArrtNTION EXT 1333 BY DOE IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFI- 771-0221 CATE OF OCCUPANCY HAS BEEN GRANTED. UBC SECTION 109 FM ORIGINAL - FILE F, OjAf RPIECAR 10/01 PINK - OWNER - GOLD - ASSESSOR Owa.i"` ==. PERMIT E)(PIRES CITY OF EDMONDS USE 111E PERMIT M NUMBER CONSTRUCTION PERMIT APPLICATION JOB ADDRESS,�,o 601 OWNER NAMEMAME OF 6 PLAT NAMEISUBDIVISION NO. LOT NO. LID NO. MAILING ADDRESS LID FEE$ PUBLIC RIGHT OF WAY PER OFFICIAL STREET MAP TES� A%w� kv RW Penns RaWifect CITY ZIP I TELEPHONE EXISTING — PROPOSED Street Use Peffnit R*Wd Wapection RaqWM REQUIRED DEDICATION— FT Sidewalk Required Underamyrid VAMO raQWrod NAME METER SIZE LINE SIZE NO. OF FIXTURES PRV REQUIRED 75 C T H HALC NO ADDRESS REMARKS U OWNER/CONTRACTOR RESPONSIBLE FOR EROSION CONTROL/DRAINAGE CITY ZIP TELEPHONE NAME ENGINEE ING REVIEWED/DATE ADDRESS FIRE REVIEWED BY DATE - 11 If CITY ZIP x� TG&P NE /,. ' I —2 f - I - TeX z, VARIANCE OR CU SHORELINE OR ADS# :INSPECTION BONP STATE UdENSE NUMBER EXPIRAT19N DATE CHECKED BY �. REO'D POSTED E3 YES E3 NO SEPA REVIEW SIGN AREA HEIGHT PRPPERTY TAX ACCOUNT PARCEL NO. COMPLETE EXEMPT ALLOWED PROPOSED ALLOWED PROPOSED -o C41 -'C'ro k -0 1 Z , , , EXP 0 NEW RESIDENTIAL 0 PLUMBING / MECH LOT COVERAGE ALLOWED PROPOSED REQUIRED SETBACKS (FT.) FRONT SIDE REAR PROPOSED SETBACKS (Fr.) FRONT URSIDE REAR 0 ADDITION COMMERCIAL COMPLIANCE OR I CHANGE OF USE . . REMODEL 0 APARTMENT 0 SIGN PARKING REO'D PROVIDED I I LOT AREA PLANNING REVIEWED BY DATE 0 REPAIR GRADING 0 FENCE CYDS X FT) REMARKS 0 DEMOLISH 0 TANK OT jffR (TLA. oGARAGE -1 RETAINING WALL 0 CARPORT ROCKERY 0 RENEWAL (rYPE OF USE. BUSINESS OR ACTIVITY) WILAIN: ffl1j,1_T1 P:AMILV CHECKED BY TYPE OF CONSTRU I CODE OCCUPANT NUMBER 0 -1;' NUMBER OF I CKMCAL . q-7 GROUP OF DWELLING STORIES 130J546;_ 1 AREAS. SPECIAL INSPECTOR AREA OCCUPANT UNITS - NUMBER REQUIRED o YES SOAR..." D ESCRIBE WORK TO BE DONE REMARKS PROGRESS INSPECTIONS PER UBC 11081FINAL INSPECTION RECVD EZeE 9"wiFL?7-1�W V VAWATION $ Description FEE Pescripflop FEE Plan Check OUIRCE GLAZING % LOT SLOPE % Building CK NO: VESTED DATE Plumbing 0 Mechanical THIS PERIIUT AUTHORMS ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLX ANY CONSTRUCTION ON THE PUBLIC Grading DOMWN (CURBS, S1DEwALrA DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE Recording Fee SEPARATE PERMISSION. Engr. Review PERmrrAPPucATto City Surcharge N: 180 DAYS PERMIT LIMM I YEAR - PROVIDED WORK IS STARTED WITHIN 180 DAYS SEE BACK OF PINK PERMIT FOR MORE INFORMATION Engr. Inspection State Surcharge 'APPLICANT, ON BEHALF OF HIS OR HER SPOUSE, HEIRS, ASSIGNS AND SUCCESORS Traffic Mitigation Plan Phk Deposit IN INTEREST. AGREES TO INDEMNIFX DEFEND� AND HOLD HARMLESS THE. CrTy OF EDMONDS, WASHINGTON, ITS OFFICIALS, EMPLOYEES, AND AGENTS FROM ANY AND Fire Review Receipt #' ALL CLAIMS FOR, DAMAGES OF WHATEVER NATURE, ARISING DIRECTLY OR INDIRECTLY F M THE ISSUANCE OF THIS PERMIT. ISSUANCE OF THIS PERMIT SHALL NOT BE EEMED TO MODIFY. WAIVE OR REDUCE ANY REQUIREMENT OF ANY CITY ORDINANCE Total Amount Due A-1 NOR LIMIT IN ANY WAY THE CITY'S ABILITY TO ENFORCE ANY ORDINANCE PROVISION." Fire Inspection L&O, Landscapelnsp. Receipt # I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION; THATTHE INFORMATION GIVEN IS CORRECT. AND THAT I AM THE OWNER. OR THE DULY AUTHORIZED AGENT OF R THE OWNE . I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUC- APPLICATION APPROVAL TION; AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED CALL this application Is not a Permit until signed by the IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO Building Official or h1aftler Deputy: and Fees are paid, and WORKMEWS COMPENSATION 18.27. FOR INSPECTION receipt Is acknowledged In space provided. =NATURE I _!AURANCE AND R M tLATURE (OWNER R(OG� Q�FIICC ATU DATE fOATE SIGNED (425) 771-0220 REW" ED 8) 'DATE ATTENTION W off 1333 IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL �%A A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFIr 771-0221 k10 I �t CATE OF OCCUPANCY HAS BEEN GRANTED. UBCSECTION 109 ORIGINAL - FILE - YELLO INSPECTOR 10/01 FAX PINK'- OWNER - GOLD - ASSESSOR 41 K END NEW SIDEWALK 1'-V 3/40 is -ION NEW C Lps, Glum AND w1_6 1120 W-6 Win Is 21'-V 16"1 SIDEU ALK PER C, TY N 0.38j &I E 10 .0 ST*o 4 OF Er momps ARD# C*_ T_ - - - - - - - - - - __T - - - - - - - - - - - - - - - 60 L-- ---- T___ Em \Q m I I NEW CUM CUIACCESS VEWAY PE Is 4 ff—i Lo 1941 WA� MOM Maw IMM 41, 13 KAA 50 X XIST TWE I!T TO REMAIN 04TH AVENUE WEST FLAN NOTE5 CD OU"PSTER ENCLOSUFS PER DETAIL I/AI-4 (D RocKERY NOT To EXCEED 3o,,,, SEE CIVIL FOR EDMONDS ROCXERY STANDARD DETAIL. (a) CROSSWALK STRIPNG PER DETAIL14/A-13. G:) "No PAwNG - FIRE LANE" siwAg EVERY soll-ou oc. AS INDICATED ON FLAK SEE DETAIL 12/A-1-3 TYPICAL STALL, SEE DETAIL 1/4-3 (D ASPHALT DRIVE, SEE DETAIL IIA-13 (D TYPICAL CUM, SEE DETAIL 2/AI-3 (1) 2"PAWING OVERRANG, TYPjCAL. (1) Ir-O" SIDE YARD SETBACK (2) 51-0" LANDSCAPE SETBACK (D 10-0" LANDSCAPE SMACK <I) w-011' BUILDING SETBACK QD V-0" CZDAR PENCE, SEE DETAIL 4/4-3 QD EXTRUDED CURB, SEE DETAIL S/AI-3 QD NONE WAY, Do Nar ENTER SIGN"" SEE DETAIL 6/4-3 QD STANDARD PARKING STALL, SEE DETAIL VAI-3 (D BARRIER PME PAWING STALL, SEE DETAIL &)AI-3 QD PARKING ARROW, WE DETAIL Iii. (ID STOP BAR SEE DETAIL 13/Al-3 (ID SIDEWALK AT LANDSCAPING, SEE DETAIL 15/Al-3 QD TYPICAL EXPANSION JOINT, SEE DETAIL Iii. (D TYPICAL CONTROL JOINT, SEE DETAIL I'VAI-3. QD BARRIER FF�EE RAMP, SEE DETAIL Is/AI-3 (ID PARALLEL PAWING STALL (ID PROPOSED GAS METER LOCATION, VERIFY W1 UTILITY COMPANY. (9) STOP SIGN, SEE DETAIL 23/Al-3 (ID EXISTING PAVEMENT EDGE (M LIGHT P0LE LOCATION, SEE DETAIL S/A-1.4 AND NOTES BELOW (a 190 WATT WALL PACK LOCATIONS, SEE LIGHTING NOTES BELOW (�D 10 WATT WALL PACK LOCATIONS, SEE LIGHTING NOTES BELOW (E) RAMP AND STAIRS, SEE ENLARAED DETAIL I/A-1.5. (�D SITE STAIRS, SEE MAIL 22/A-13. (ID 50 WATT FIER MOW LUMINAIRE, SEE LIGHTING NOTES BELOW. (�D EAVE OVERHANG, VTYPICAL (ID BARRIER FREE aim CUT, DESIGN MST MEET arr OF EDMONDS STANDARDS. Ifu %el-V =A1121 RW4 FKALum FVLE 10 1= WUX,-ATEED. I I I , I I I I I I - = (�D NEW LOCATION EXIST POWER POLE. PROPOSED LOCATION __x ------------------------------- TRANSFORMM LOCATION TO BE VEIRIFIED W1 UTILITY COMPANY. -1 (�D CZNC- PAD FOR MAILBOXES. LOCATION AND MAILBOX DESIGN 0-38138111 E g L TO BE COORDINATED W1 POST OFFICE. (�D ENTRY ELEMENT, SEE DETAILS 1, 2, AND 31 SHEET A-1.5. N 0038,38" E END OF NEW CEDAR FENCE. 0) FIRE HYDRANT LOCATION($) (Z) EXISTING FIRE HYDRANT LOCATION(S) (22) CROSSWALKS PER CITY OF EDMONDS, SEE CIVIL r= (9) YELLOW CMNG, FROM Pow oF ruRvATum io, To INSIDE OF - NEW SIDEWALK SITE AND 30'TO STREET LANDSCAPE SETBACK Lj (ZD OUTLINE OF EXISTING ADJACENT BUILDING VEGETATION AT FENCE LINE (a) WET 510FILTRATI SWALE, SEE CIVIL FOR DETAILS GUARDRAIL MR DETAIL S/A-1.4. G) FIRE DEPARr-1ENT CONNECTIONS 5LDG. A - AVM GRADE ELEV. 5LDG; C - AVRG. C-iRADE ELEV. 5'-0" LANDSCAPE SETBACK A as +S936' A MAINTAIN EXISTING VEGETATION 5 12- 4� 5 2 AT FENCE LINE Can + 131.1s, Cc + W.63' Do + ft44' + ft13, AVGL GRADE W.34' AVG. GRADE as + Wh5l + 12825' f��u : 128.15' wAtrr + 12MI (W/ 14EWT BONUS) 12M(WI WEIGHT BONUS) BLIXs. 5 A GRADE ELEV. BLOG, D - AVWA QkADE ELEV� 5 z + W.42' 5 + 96.11' Cc + S.131, Cz + S633, 13 + 131fos' D - + W.41' AV& GRADE + S1.22' AVG. GRADE - + 913' ACTUAL sis + 1210 ACTUAL a + 121.251 MAXIMUM a 4,12122' (W/ MIC114T BONUS) MAX" 1213, (WI HEIGW BONUS) END NEW 4;lr*jmlw ilf 2 6 ul 51-On LANDSCAPE SETBACK 299BSI N 0038'3811 E ------ :ill — . - PO "E LANE H9 PARKONO IV URB YEL.OW, *Typ. ENTIRE LER �`mmlff NEW CURB, GUTTER AND SIDEWALK MR CITY NEW CUR5 CUT ACCESS DRIVEWAY OF EDMONDS STANDARDS PER CITY OF EDMONDS STANDARDS. 41 GE EXIST. CURB TO i NEW CUM CUT DRIVEWAY CUT EXIST. CURB PER r REMAIN. TO ACCEPT NEW ITy or- STANDARDS. (2)RADIUS I a — a A. =F - - - — — — — — — F RE AMR NO PARKONG —FORE LAME NO 1p % 4 20'-011 q _T EXIST. TO BE felol ftSVI N 0"3838" E r �Nw CURB 500 r rL A ROVED BY PLANNING 17, PARKING SPACES REQ`D: 6 (o Mill PARKING SPACES PROPOSED: ZL BARRIER 121EE PARKING SPACES: 5 1 Tj= 'I=L AN 5CALE: 111=20'—O" GENER4L SITE LIGHTING NOTES: LUMINAIM : 28 LU11ENS 16000 LLF - SPIN - 0 TEST NU11SER- HP-01146 HUBBELL LWTNG - DIVISION P140TOMMIC CAT. NO.: PVL-OIUX-xxx DESCRIPtION: PERIMALITER SERIES LAMP TYPE- LUWAo5V` LAMP DESCRIPTIol 150 WATT CLEAR HIGH MREawf�g SOpIUj :LECTOP_- SPECULAR ALUMM ENCLOSURE: PRISMATIC POLYCARBONATE LL11INAiM: 2S ------------------------ 50 APS. WALL PACK LUMEM m -16000 LLF a .8 SPIN - 0 TEST NIMR- HP-01146 HUBBELL LIGHTING - DIVISION PHOTOMETRIC CAT. NO.: M-OWS-xxx DESMIFill PERIMALITER SERIES LAMP TYPE: LUSO/SSV LAMP DESCRIPTION: W WATT CLEAR WW PRESSURE SODIUM REPLECTOIt SPECULAR ALUMM" ENCLOSURE: PRISMATIC POLYCARBONATE LUMINARE - 30 ---------­------------ 10 WPS WALL PACK LUMENS 2, 5" LLF - .8 SPIN - TEST CAT. NO.: NR3-Wl DESCRIPTION; PERJMALUX NIRG-3W SERIES LAMP LAMP DESCRIPTION.- 10 WATT WS REFLECTOR. Al PANTED WHNW ENCLOSURE- PRISMATIC POLYCARSONATE LtNINAIRE: 33 ii�W�R6WETi�ORATIVE LUMINAIRE CAT. NO.: FcW Swi DESMIPTICK. PC LWTNG EXT. CAST AWINIUM LAMP TYPE: LAMP DESCRIPTION: 50 WATt, HIPS 4412 @ R S ED CARL F. IRSCHER STATE OF SHINGTOMN z C1 6 PKANN: CHECK: JOB NO: LU 0 < Z < K Z z z OL elk < tu tu tu IL 9141iiiii A71— j7.— �__ 1. v ., D 124_�5&6 BUILDING DEPT. 9Hr=r=T9 f RE-RE5USMITTAL FEB 2 6 2002 BUILDING DEPT. END NEW SIDEWALK NEW C Lums, GU AND SIDEU ALK PER C OF: EC MONPS sTANr>AF" &-loo _r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ROA 0 1ju 11 3/4v 3: C43 NEW C4RB A=SS DRIVEWAY' PER CITY OF EDMONDS 5TANDARC.S. G> 11 MAP 41 ID TYP- 4 VIM. L —1 C4 24�4)` dki Sim MEN m . . . . . . . ... 0 IF FR "12ro + CS.3-51 TO �SPRIWQZR RISEfltF,- — - — — - - - - - - - - - - - - - - - - - - - - MEOF �'_ EXIST TREE TO IREMAN 54TH AVENUE WEST 2140 Id 16'-4 . — —I— a -.Z — N 0038,381, E -- — — — — — — --- — — — 0>_ — W-wo N 0038MAll 9 51-51 .0 ---------- cn a W0311111, E I an I m a b I mol 2 ul 9 V-0"LANDSCAPE SETBACK 2131-Ml N 0038'3811 E R5 1-0 N la a TYP. FAINT CUF43 YEL.OW, *Typ. ENTIRE Lm au 51TE FLAN NOTE5 (D DUMPSTER S4CLOSURE PER DETAIL I/AI-4 (D ROCKERY NOT TO EXCEED 30" SEE CIVIL FOR EDMONDS ROOMIRY STAND�i6 DETAIL. (D CROSSWAIX STRIPING MR DETAIL14/A-13. (D NNO PARKING - FIRE LANE" SIGNAGE EVERY 50--oll O.C. AS INDICATED ON FLAK SEE DETAIL 12/A-1-3 (D TYPICAL STALL, SEE DETAIL 1/Al-3 (D ASPHALT DRIVE, SEE DETAIL IIA-13 (a) TYPIC& CURB, SEE DETAIL 2/Al-3 (E) 2' PARKING OVERHANG, TYPICAL. (:I) to-O" SIDE YARD SETBACK 10 51-011 LANDSCAPE SETBACK CD 10-0" LANDSCAPE SETBACK QD 5'-0" IBUILDING SETBACK (a) w-0" CZDAR FENCE, SEE DETAIL 4/Al-3 (9) EXTR=ED CUIRB, SEE DETAIL S)AI-3 (Z) "ONE WAY, 00 NOT ENTER SIGNu, SEE DETAIL 6/Al-3 QD STANDARD PARKING STALL, SEE DETAIL I/AI-3 (0) BARRIER FREE PARKING STALL, SEE DETAIL &)AI-3 (ID PARKING ARROW, SEE DETAIL IO/Al-3. S SEE DETAIL 13/Al-3 (a SIDEWALK EDGE AT LANDSCAPING, SEE DETAIL IS)AI-3 QD TYPICAL EXPANSION JOINT, SEE DETAIL 16/Al-3. QD TYPICAL CONTROL JOINT, SEE DETAIL tl/Al-3. (ID BARRIER FREE RAMP, SEE DETAIL I$/AI-3 (0 PARALLEL PARKING STALL (ID PROPOSED GAS METER LOCATION, VERIFY W1 UTILITY COMPANY. QD STOP SICK SEE DETAIL 23/Al-3 21 EXISTING PAVEMENT EDGE QD LIGHT PME LOCATION, SEE DETAIL S/A-1.4 AND NOTES BELOW (a 190 WATT WALL PACK LOCATIONS, SEE LIGHTNG NOTES BELOW (�D 10 WATT WALL PACK LOCATIONS, SEE LIG44TNG NOTES BELOW (ID RAMP AND STAIRS, SEE EMAR3ED DETAIL VA-I.S. (2) SITE STAIRS, SEE MAIL 22/A-13. (ID 90 WATT PIER MOUNT LUMINAIRE, SEE LIGHTNG NOTES BELOW. (�D EAVE OVERHIAN63, 1811 TYPICAL (9) DARRIER FREE CURB CUT, DESIGN MOT MEET CITY OF: EDMONDS STANDARDS. =A15 I Ims MAWR r-.;&= 10 t* FELOCATED. (ID NEW LOCATION EXIST POWER POLE. PROPOSED LOCATION Q r --------------------------- t- TRo4ffOIw4lM LOCATION TO BE VERIFIED W1 UTILITY COMPANY. 00381will'. 14 (ID CONC. PAD FOR MAILBOXES. LOCATION AND MAILBOX DESIGN .14. TO BE COORDINATED W1 POST OFFICE. (�D ENTRY ELEMENT, SEE DETAILS 1, 2, AND 3i SHEET A -IS. 6%Ssl N 0*38'38" E END OF NEW CEDAR 0) FIRE HYDRANT LOCATION(S) M FENCE. (a) EXISTING FIRE 14YDRANT LocATIoN(s) (D CROSSWALKS MR CITY OF EDMONDS, SEE CIVIL (a) YELLOW CUFaING, FROM POINT or- cuRvATuRE io, To INSIDE OF NEW SIDEWALK SITE AND 301 To STREET LANDSCAPE SETBACK-- LA (9) OUTLINE OF EXISTING ADJACENT BUILDING MAINTAIN EXISTING VEGETATION CURBLINE OF EXISTING ADJACENT PAW..ING LOT AT PENCE LINE (a) WET 510FILTRATION WALE, SEE CIVIL FOR DETAILS (2) GUARI)RAIL MR DETAILS/A-1.4. 0) FIRE DEPARMENT CONNECTIONS BLDG. C - AVRC% GRADE ELEV. i'-011 LANDSCAPE SETBACK A A =-+W.611 1AINTAN EXISTING VEGETATION 5-+W.15' 5 a +w36,-- 4T FENCE LINE On + alls, Cc + W.63, On + ft44' Da + ftl3l CD AVa GRADE - + W34' AV& GRADE - + W.0' ACTUAL = : 12625' ACTUAL a + 128.15' MAXM I28_*'(Wl HEIGHT 50") MAX" a + I28h5l (WI Wrd4T BONUS) BLDG. 5 - AM741 GRADE ELEV. BLDG. D - AVRG. GRADE ELEV. A a +Sbhl' A is +W23' 5 a + W.42' 521+S6.111 Cm + W.sl' Co + 9633, on +slhs' 0- + W.411 AVUL GRADE Z' + IB1221 AVC-L GIRADE - + 1513' -------------------------- �j ------ ACTUAL - + 1210' ACI`UAL - + 12125' END NEW MAX" + I21-22'(WV WIG14T BONUS) MAX" + 12131 (W/ HEIGHT 5ONUS) &I wrmvA%%6T%% NEW CURB, GUTTER AND SIDEWALK MR CITY NEW CURB CUT ACCESS DRIVEWAY OF EDMONDS STANDARDS PER CITY OF EDMONDS STANDARDS. 41 EXIST. CURB TO CUT EXIST. CURB NEW CURB CUT DRIVEWAY REMAIN. MR CITY OF: 5 STANDARDS. TO AMEPT NEW (2)RADIUS — — — — — — — — — — — — FORIE LANE NO PARKONG 20'-Ov let 4 :4 POIRTION tu 11 EXIST. CL w TO BE zE- - - - REMOVED WtW_ N. 0-38-3811 E �Nm CURB QD 12 APPROVED BY PLAN u� -z- PARING SPACES Rll=� 8 'A P-.QE8;___ 51TE f=LAN I 5GALE: P=20'—011 GENERAL SITE LIGHTING NOTE& LUMINAIRE : 28 Twi4�i;Z� ------ LUMENS LLF - SPIN a 0 TEST NIJIMP.- HP-01146 14UMELL LIGHTING - DIVISION PHoToMETIRIc CAT. NO.: PVL-0IU*-xxx DESCRIPTION: PERIMALITER SERIES LAMP TYM: LUWMV LAMP DESCRIPTIOK- 190 WATT CLEAR 141W PRESSUIRE SODIUM REFLECTOIZ- SPECULAR ALUMINUM ENCLOSURE: PRISMATIC POLYCAJR50NATE LU11NAIM : 2S LUMEM 16000 LLr- a SPIN 0 0 TEST NU15ER- HP-01146 HUBBELL LIC44TNG - DIVISION P140TOMEMC CAT. NO.: PvL-0506-xxx DESCRIPTION: PERIMALITER SERIES LAMP T`TM: LU50)55V LAMP DESCRIPTION: 50 WATT CLEAR HW PRESSURE SODIUM REFLECTOR. SPECULAR ALU11M ENCLOSURE: PRISMATIC POLYCAM30NATE LUMINAIRE: 30 ------------------------ 10 14PS WALL PACK LUMENS 5" LLF - SPIN c 0 TEST N115ER- AP-03412 HU55ELL LIGHTING DIVISION - m4OTOMMc REpoRt CAT. NO.: NFZG-301 DESCRiPTIONz- PERIMALUX NIRG-3W SERIES LAMP TYPE: LAMP DESCRIPtION.- 10 WATT HIPS FWEcfoR.- AL, PAINTED u4flW m4moswm_ PRISMATIC poLycAFaoNATE LUMINAIRE 33 ------------------------ 50 WS PIER MOUNT DECORATIVE LUMINAIRE CAT. NO.: FCW 5001 DESCRIPTION: PC LIGHTNG EXr. CAST ALUMNIUM LAMP TYPE: LAMP DESCRIPTION: 50 WATT, HPS cool] "12 z OL < VRAM: SH C,HEOK: OP. JOB NO: lqaocpl Z X < z z z OL lu z < tu lu SHF��T: PIS -'o 13UILDING DEPT. OF: SHEETS RE-RE5UBMITTAL vu 2 6 N92 BUILDING DEPT, , FIF T Fif L E 7/26/02, 08:10 AM01040-Cl.plt N.W. 1A OF SECTION 6, TOWNSHIP 25 NORTH, RANGE 6 EAST, W.M. KING COUNTY, WASHINGTON PROJECT TEAM OWNER: CIVIL ENGINEER: STAN PIHA POGGEMEYER DESIGII GROUP FOURTH & BLANCHARD BUILDING 512 SIXTH STREET SOUTH #202 2101 47H AVENUE, SUITE 250 KIRKLAND, WA 98033 SEA TTLE, WA (425) 827-5995 (206) 443-8212 FAX (425) 828-4850 FAX (206) 443-8212 FAX CONTACT. CHUCK S.41ELDS, P.E. ARCHITECT. SURVEYOR: CDA ARCHITECTS, INC D.R. STRONG, CONSI)LTING ENGINEERS 19524 BALLINGER WAY NE 10604 N.E. 38TH PLACE #101 PO BOX 55429 KIRKLAND, WA 98033 SEATTLE, WA (425) 827-3063 (206) 368-9668 (425) 827-2423 FXX (206) 368-9558 FAX CONTACT. WC BANFS INDEX Cl GENERAL NOTES & VICINITY MAP C2 TEMPORARY EROSION AND SEDIMENTATION CONTROL PLAN C3 GRADING AND DRAINAGE PLAN C4 WATER AND SEWER PLAN C5 PROFILE 84TH AVENUE CIS PROFILE 236TH STREET SW C7 NOT USED C8 DRAINAGE DETAILS C9 SITE DETAILS CIO CITY OF EDMONDS STANDARD DETAILS — FILTER FABRIC FENCE FILTRATION SYSTEMS — TEMPORARY SEDIMENT TRAP FOR CATCH BASINS — STANDARD TYPE T CURBIGUTTER DETAIL — STRAW BALE DAM FILTATION SYSTEMS — STABILIZED CONSTRUCTION ENTRANCE — HIGH TRAFFIC LOAD DRIVEWAY ACCESS (WITH CONCRETE DRIVEWAY APPROACH) Cil CITY OF EDMONDS STANDARD DETAILS — CURB RAMP TYPE 4 — CURB RAMP TYPE 5 — RAMP DETAIL FOR TYPE 5, 5.1, AND 6.1 RAMPS — STANDARD TYPE T CURBIGUTTER DETAIL — CONCRETE SIDEWALK — CROSSWALK DETAIL 99 5 PROJECT co LOCATION <C 236TH ST SW 104 N 205TH ST. 104 LEGAL DESCRIPTION - PARCEL A: LOTS 9, 10, AND 11 IN BLOCK I OF FRUITLAND ACRES TO LAKE BALLINGER, ACCORDING TO PLAT RECORDED IN VOLUME 10 OF PLATS AT PAGE(S) 47, IN SNOHOMISH COUNTY, WASHIPGTON; EXCEPT THE EAST 120.00 FEET THEREOF. PARCEL B: THE WEST 60.00 FEET OF THE EAST 250 FEET OF LOT 12 IN BLOCK I OF FRUITLAND ACRES TO LAKE BALLINGER, ACCORDING TO PLAT RECORDED IN VOLUME 10 OF PLATS AT PAGE(S) 47, IN SNOHOMISH COUNTY, WASHINGTON; EXCEPT THE WEST 8.47 FEET OF THE NORTH 30-00 FEET THEREOF, ALSO, THE WEST 30 FEET OF THE EAST�220.00 FEET OF LOT 13 AND THE WEST 35.00 FEET OF THE EAST 225.00 FEET OF LOT 14 IN SAID BLOCK 1. NOTES: THIS DEVELOPMENT SHALL BE CONSTRUCTED USING CITY OF EDMONDS, YEAR 2001, STANDARD SPECIFICA71ONS AND DETAIL& PERWOUS AREA = 30,102 SQ. FT. (0.691 ACRES) IMPERVIOUS AREA = 48,137 SO. FT. (1.105 ACRES) WATER ZONE: 35 PSI OLYMPIC VIEW WATER AND SEWER DISTRICT MANHOLE. 1-132 C12 CITY OF EDMONDS STANDARD DETAILS C15 CITY OF EDMONDS STANDARD DETAILS — PIPE BEDDING —,RESIDENTIAL DOUBLE CHECK ASSEMBLY — TYPICAL TRENCH SECTION (STANDARD D.C.V.A. 2- AND SMALLER) — TYPICAL TRENCH SEC71ON—FOUNDA17ON STABILIZATION — 314"—l" WATER SERVICE INSTALLATION — TYPICAL TRENCH SECTION —CONTROL DENSITY FILL — 1-1/2"-2" WATER SERVICE INSTALLATION — TYPICAL WATER LINE TRENCH SECTION — CONCRETE THRUST BLOCKING C13 CITY OF EDMONDS STANDARD DETAILS — METAL HANDRAIL — SEWER CLEANOUT DETAILS — ALUMINUM PEDESTRIAN HANDRAIL — TYPE I MH (SANITARY) Tvr)if,Ai cinr crucD C16 DRIVEWAY UTILITY PROFILES C14 CITY OF EDMONDS STANDARD DETAILS — ARV ASSEMBLY TYPE 1) — ARV ASSEMBLY RYPE 2) — BLOW —OFF ASSEMBLY — COMMERCIAL DOUBLE DETECTOR CHECK ASSEMBLY �PLAN) E) — COMMERCIAL DOUBLE DETECTOR CHECK ASSEMBLY PROFIL — FIRE HYDRANT ASSEMBLY A3f� APPROVED FOR CO TION 'c'ON F�� — L CIfY_ ENGINEER v DATE' BUILDINU 01:41 L D. Bo y.WAS& A ilia I c _10- \ 21018 y lor to EXPIRES OCTOBER 24, 2002 (7 cy) z L0 0 cy) 1-� Lr) C) r I 00 E- Ln C14 E- C4 P4 pq ro ff') 6 (13)0, 0 Z z F_ z C) < z t__4 E-4 Of �D CD 04 Z 0 Ld 0 C/) C) F_ Ld W ry Co JOB NUMBER 01040 DESIGNED BY cs DRAWN BY EMC/JG 1 CHECKED BY RDB/CS DATE 01/ . 29/0 2 SHEET NUMBER c 1 omm 1 /')0 In') nlf)Af)—(%l 1 t) ') r, .I - - , - - - , - , - - . . — 7/25/02, 11:15AM01040-C2.pit J �.7 f , J 4- I Ln q.,' _T'l LLJ Z: __J -3: CD _AJ C) f I -.7.7 ------- 0 11+00 12+00 U't I 1 1­21-1 V L IV U L V-V-,L J 1 1300 Ll T 1­. 9 1-_�J i-I Li C-) �0 Lr F LLJ T.- I LJ_J T_ 18.30.05ODevelopment approval standards for erosion and sedimentation control (ESC) plan. A. ESC Minimum Requirements. All activities necessitating a clearing or grading permit and all utility projects consisting of more than 500 lineal feet of trench excavation shall be required to control erosion and sediment during construction and to permanently stabilize exposed soil resulting from construction. Projects involving a critical area may also be required to comply with any combination of the ESC minimum requirements. Compliance will be demonstrated through the implementation of an approved ESC plan. Guidelines for preparing ESC plans are provided in the manual. The plan must address the following requirements: 1. ESC Minimum Requirement - Construction Access Route. Construction vehicle access shall be, whenever practical, limited to one route. Access points shall be stabilized with quarry spoils or crushed rock to minimize the tracking of sediment onto public roads. If sediment is transported onto a road surface, the roads shall be cleaned thoroughly at the end of each day. Sediment shall be removed from roads by shoveling or sweeping and be transported to a controlled sediment disposal area within 24 hours. Street washing shall be allowed only after sediment is removed in this manner. 2. ESC Minimum Requirement - Stabilization of Exposed Areas. All soils exposed by land disturbing activities shall be stabilized by suitable applicati I on of BMPs, including, but not limited to, sod, hydroseeding, or other vegetation, plastic covering, or mulching. All BMPs shall be selected, designed, and maintained in accordance with the manual. The exposed soils shall be stabilized according to an approved timetable. (Typically, no soils shall remain exposed for more than two days from October 1 through April 30 and no more than seven days from May 1 through September 30). 3. ESC Minimum Requirement - Protection of Adjacent Properties. Adjacent properties shall be protected from sediment deposition by appropriate use of vegetative buffer strips, sediment barriers or filters, dikes or mulching, or by a combination of these measures and other appropriate BMPs. 4. ESC Minimum Requirement - Maintenance. All erosion and sediment control BMPs shall be regularly inspected and maintained by the owner to ensure continued performance of their intended function. All maintenance and repair shall be conducted in accordance with the manual. 5. ESC Minimum Requirement - Other BMPs. As required by the city, other appropriate BMPs to mitigate the effects of increased runoff shall be applied. 6. Erosion and Sediment Control Requirement - Underground Utility Construction. The construction of underground utility lines shall specificoll address the following: y a. Erosion control for excavated and stockpiled materials, b. The placement of excavated material where consistent with safety and space considerations shall be placed on the uphill side of trenches; c. Trench dewatering systems (must discharge into sediment traps, sediment ponds, or other acceptable means); d. Tracking and spilling of materials on streets due to hauling; e. Daily cleanup and street maintenance. 7. Additional ESC Minimum Requirements for Larger Developments. All new development and redevelopment that includes land disturbing activities of greater than, or equal to, one acre in addition to meeting the minimum requirements set forth above shall comply with ESC requirements listed below. 8. ESC Minimum Requirement - Delineate Clearing and Easement Limits. In the field, mark clearing limits and/or any easements,. setbacks, sensitivelcritical areas and the buffers, trees and drainage courses. 9. ESC Minimum Requirement - Sediment Trapping. Prior to leaving the site, storm water runoff shall pass through a sediment pond or sediment trap, or other appropriate 6MPs. Sediment ponds and traps, perimeter dikes, sediment barriers, and other BMPs intended to trap sediment on -site shall be constructed as a first step in grading. These BMPs shall be functional before land disturbing activities take place. Earthen structures, such as dams, dikes, and diversions shall be seeded and mulched according to an approved timetable. 10. ESC Minimum Requirement - Cut and Fill Slopes. Cut and fill slopes sholl be designed and constructed in a manner that will minimize erosion. In addition, slopes shall be stabilized in accordance with ESC Requirement No. 2. 11. ESC Minimum Requirement - Controlling Off -Site Erosion. Properties and water ways downstream from development sites shall be protected from erosion due to increases in the volume, velocity, and peak flow rate of storm water runoff from the project site. 12. ESC Minimum Requirement - Stabilization of Temporary Conveyance Channels and Outlets. All temporary on -site conveyance channels shall be designed, constructed and stabilized to prevent erosion from the expected velocity of flow from a two-year, 24-hour frequency storTn for the developed condition. Stabilization adequate to prevent erosion of outlets, adjacent stream banks, slopes and downstream reaches shall be provided at the outlets of all conveyance systems. 13. ESC Minimum Requirement - Storm Drain Inlet Protection. All storm drain inlets made operable during construction shall be protected so that ston-n water runoff shall not enter the conveyance system without first being filtered or otherwise treated to remove sediment. 14. ESC Requirement - Removal of Temporary SMPs. All temporary erosion and sediment control BMPs shall be removed within 30 days after final site stabilization is achieved or after the temporary BMPs are no longer needed. *fropped sediment shall be removed or stabilized on site. Disturbed soil areas resulting from removal shall be permanently stabilized. 15. Erosion and Sediment Control Requirement - Dewatering Construction Sites. Dewatering systems shall discharge into a sediment trap or sediment pond. 16. Erosion and Sediment Control Requirement - Control of Pollutants other than Sediment on Construction Sites. All pollutants other than sediment that occur on site during construction shall be handled and disposed of in a manner that does not cause contamination of storm water. 17. Erosion and Sediment Control Requirement - Financial Liability. Performance bonding, or other appropriate financial instruments, shall be required for all projects to ensure compliance with the approved erosion and sediment control plan. [Ord. 3013 § 1, 1995]. CIVIL CONTRACTOR CONSTRUCTION AND SEQUENCE 1. ATTEND PRECONSTRUCTION METING WITH THE CITY OF EDMONDS ENGINEERING INSPECTOR. 2. INSTALL EROSIONISEDIMENTA71ON CONTROL MEASURES, AS INDICATED ON THE PLANS (CONSTRUCTION EXIT AND FILTER FENCE). TES.C. MEASURES SHALL BE INSTALLED, INSPECTED, APPROVED AND OPERATING BEFORE ANY MASS GRADING OR LAND CLEARING. 3. INSTALL DETENTION VAULT MANHOLES, ESC CONTROL STRUCTURE AND INLET FILTER. 4. CONSTRUCT STORM DRAIN TO WET VAULT. WET VAULT TO BE USED AS TEMP. DETENTION DURING CONSTRUCTION. MONITOR OUTFALL TO INSURE TURBIDITY LEVELS ARE WITHIN THE CITY OF EDMONDS REQUIREMENTS. 5. CLEARING AND GRUBBING AND REMOVAL OF DEBRIS, OLD STORM SEWER, FOOTINGS, FOUNDATIONS AND STOCK PILING EXISTING TOP SOIL. 6. ROUGH GRADE BUILDING PADS A,BC & D TO 8" BELOW FINISHED FLOOR ELEVA71ON SHOWN ON GRADING AND DRAINAGE PLAN. 7. INSTALL BALANCE OF STORM DRAINAGE FACILIIIES. INSTALL INI ET PROTEC71ON ON NEW CB'S. INSTALL SS AND WATER UTILITIES. TIE IMPERVIOUS SURFACES TO COMPLETED DRAINAGE SYSTEM AS SOON AS POSSIBLE. 8. INSTALL DRY UNDERGROUND UTILITIES, IRRIGATION SYSTEM & STREET LIGHTS (BY OTHERS). 9. GRADE SITE TO ROAD SUBGRADE LEVEL AND LANDSCAPE AREAS (ALL OF SITE NOT COVERED MTN BUIDINGS OR PAVING) TO 4- BELOW FINISHED GRADE CONTOURS. 10. INSTALL CURB/GUTTER, PAVING AND SIDEWALK. 111. ERECT STRUCTURES (BY OTHERS MAINTAINING TIES.C. AS REQUIRED). 12. PLACE 4" TOP SOIL ON LANDSCAPE AREAS. 13. REMOVE EROSIONISEDIMENTA71ON CONTROLS WITHIN 30 DAYS AFTER POTENTIAL FOR EROSION HAS PASSED. TRAPPED SEDIMENT SHALL BE REMOVED OR STABILIZED ON SITE. DISTURBED SOIL AREAS SHALL BE PERMANENTLY STABILIZED. 14. COVER EXPOSED, UNLANDSCAPED, UNPAVED AREAS. 15. CLEAN STORM DRAINAGE SYS ' TEM AND VAULT, AS NECESSARY. DO NOT FLUSH SILT FROM CATCH BASINS INTO STORM SYSTEM. 16. CALL DIAL-A-D16 1-800-424-5555) FOR UNDERGROUND 071UTY LOCATIONS. Mao ;W Nam a got 00 ON ofm Mao ,1141 *1 '' 0040 vow, we 0000 I I * 1 m 1140 0% W*_. I LEGEND FILTER FABRIC FENCE FILTRA71ON SYSTEM DWG. E 1.1 SHEET CIO. TEMPORARY CONSTRUC71ON ENTRANCE (CITY STD. DWG. 503) Z 0 LO C) r 00 V) Ln C-4 E­ 1:14 0 Z Z 0 F- CD Z X Z V) tc Z rl__011 U: �4 �D CD c" Z 0 �L_L' E5 V) ZE� :D (D Ln CD LLJ SURFACE DRAINAGE SWALE SEE 4/C9 NOTE: Fill MATERIAL TO BE COMPACTED TO 95% MODIFIED PROCTOR ASTM D1557 EXCEPT LANDSCAPE AREAS. APPROVED FOR CONSTRUCHON Kva_� 6!4� CITY ENGINEER DATE A T I %I 'EM 1iis - ___ 0 10 20 40 SCALE: 1"=20' & D. B 0 WA 1"? NNE FEXPIRES OCTOBER 24, W02 1 1/15/02 01040-C2 10:49am 7/25/02, 11:12 AM01040-C3.plt NOTES: YD 5 ". y, % 1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE CITY OF DUMPSTER ENCLOSURE PER DETAIL X/A-1.1 RIM=447.50 CB 7 EDMONDS AND THE STANDARD SPECIFICATIONS FOR MUNICIPAL PUBLIC IE=446 50 RIM=448.25 WORKS CONSTRUCTION, 2000. YD 4 51 LF I" Sl IE=445* 75 PEDESTRIAN STRIPING, 4' WIDE RIM=448.75 SL=1.5% 9 82 LF 6n SD 2. CONNECT ALL ROOF DRAINS TO DETENTION PIPE SYSTEM. IE=447.75 -NO PARKING - FIRE LANE' SIGNAGE EVERY 50'-0" O.C. AS INDICATED ON PLAN SL=1.22% (10 3. CMP SHALL BE 16 GAGE GALVANIZED STEEL OR ALUMINUM. STEEL x SE 448.5 DETENTION PIPE SHALL HAVE ASPHALT. TREATMENT 1 COATING OR - ---- - BETTER. DETENTION PIPE SHALL BE 3XI CORRUGATIONS 16 GAGE. TYPICAL STALL, 8.5' x 16.5' 7 SE 449. J I X 85' N 0*38'38" E [7-7. 1 ASPHALT DRIVE, SEE DETAIL THIS SHEET -REINFORCED ASTM 7Z 4. CONCRETE 12" STORM DRAIN PIPE SHALL BE NON EXIST. IE =449.59 W 1.0 H -76 AND CORRUGATED POLYETHYLENE PIPE (CPEP) SHALL BE SMOOTH TYPICAL CURB, SEE DETAIL THIS SHEET C i_51 H_ INTERIOR PER AASHTO M252 IN 8 INCH SIZE AND AASHTO M294S IN 2.5 H A k, _T -0- SIDE YARD SETBACK 10' SIZES 12 INCH THROUGH 36 INCH. DUC71LE IRON PIPE SHALL BE CL 30' 52. 2.5' H 1 1.3 H PVC SHALL BE EQUAL TO SANITARY SEWER PIPE AS SPECIFIED BELOW. 5'-0" LANDSCAPE SETBACK A Aw, r, P. z ANY PIPE DESIGNATED AS "SO" MAY BE ANY TYPE LISTED HEREIN. CPEP ABANDON EXISTING CULVERT 5.5 GRADE MUST BE 0 YD 2 t NOT ALLOWED UNDER TRAVELED SURFACES UNLESS 2' MINIMUM COVER. 10'-0" LANDSCAPE SET13ACK lg,-Lol SEE NOTE 9 e-1 MAINTAINED 3' ABOVE RIM 444.75 IE=442.75 19 5. SANITARY SEWER PIPE SHALL BE PVC ASTM 3034, SDR 35. YARD DRAIN SUMP PUMP FF AT PERIMETER -771-0220, EXT 1326) FOR x 6. CALL ENGINEERING DIVISION (425 (J�) CITY CROSS WALK F -1 BL 3 SEE DETAIL 3/C8 Lu A D G-- - B 4- BF EL 445.5 PREBACKFILL AND FINAL INSPECTIONS. PER STD. DETAIL v 1 BF EL 446.76Y 4- VC DWG. E 3.210 _12- YO 1 7. RESPONSIBILITY FOR OPERATION AND MAINTENANCE OF DRAINAGE I I E URE LINE yo 3 ArO-' RIM=444.75 SYSTEMS ON PRIVATE PROPERTY IS THE RESPONSIBILITY OF THE (J�) TYPE 2 CURB RAMP 00 3 co cn RIM=446.10 2, IE=444.10 IE=442.75 6' SO PROPERTY OWNER. MATERIAL ACCUMULATED IN THE STORAGE PIPE MUST 6 a,- lo� PER STD. DETAIL V) SL 1. 5% BE FLUSHED OUT AND REMOVED FROM CATCH BASINS TO ALLOW PROPER DWG. E 2.27.1 1 2,4.0 Ecp OPERATION. THE OUTLET CONTROL ORIFICE MUST BE KEPT OPEN AT ALL Flo c'] L0 3.4 ERGENC TYPE TIMES. -0 H (J�) PAINT COR13 YELLOW c� RIM=448.,00 UJI c 1. 7 OVERFLOW 10' FROM DRIVEWAY ce ol� : � - IE=444 6 (.3 CL QO 0" LmR 8. LOCATION OF EXISTING OTIU71ES IS APPROXIMATE AND ALL UTILITIES L) Ju­., I L-4 1 79 1930,10" SD 4 RIM-449.39 (J�) PAINT CURB FOR 13US STOP (TO BE COORDINATED JJL-V.V 10 IF=444, MAY NOT BE SHOWN. IE=447.30 .13 S. __,n/sLI 9�5 F;, lr6' CONTRACTOR SHALL VERIFY LOCATIONS AND CD !:H,F- ! 1 1 i % I I ELEVATIONS AS REQUIRED. CALL 1-800-424-5555 FOR UTILITY WITH COMMUNITY TRANSIT) 5a V) CB lof 1:6" RIM= 7.75 C> LOCATIONS PRIOR TO ANY EXCAVATION. ISTOP�-_ ------ i7rj_cd 14 C�w- k- I , IE= 78 1-5 J L SIGN I 0j. 7 YNITA RY SP P 9. THE CONTRACTOR IS RESPONSIBLE FOR EROSION AND SEDIMENTATION LEGEND: CONTROL AT ALL TIMES UNTIL PROJECT COMPLETION. ENSURE SILT DOES EASEMENT T CR PROPERTY LINE *A' NOT ENTER OFF -SITE STORM DRAIN SYSTEMS AND MATERIAL IS NOT 4-1c il j yp. 0 TRACKED ONTO CITY STREETS. TESC MEASURES SHOWN ON THESE % C> i39-LF-"D- -A 114 . PLANS ARE A GUIDE THE CITYS INSPECTOR MAY REQUIRE ADDITIONAL SETBACK AND EASEMENT LINES cli SL--0.60% 1.5%' CL a5l 1�1 IO'L MEASURES. 10 RIM=448.5 STORM DRAIN '4 45 E NT IE=446.81 10. ALL TRENCH BACKRLL FOR UTILITIES ON 236TH ST. SW AND =3 13 1 1- -1, t N 0'38'jF E OT ;; I 1 1% - .1 N !SIGN C�o 84TH AVE. W SHALL BE CONTROL DENSITY FILL ABOVE PIPE BEDDING. E3 CATCH BASIN TYPE I A. THE CONTRACTOR SHALL CALL THE CITY OF EDMONDS INSPECTION LINE (425-771-0220, EXT. 1324) FOR ALL TRENCH AND PAVEMENT BF EL XXXXX BASEMENT FLOOR SLAB ELEVATION L4 I r1l 15 1 _.n RESTORATION. IL X /%[) I -c, / �j g.­..j:*­__ ct: ca 19 \ I? ll� EASEM 1�v YD REMOVE PIP FG XXX XX FINISHED GRADE EL OUTSIDE BUILDING )15 7 R001=448.00 C=l V) SEE N IOTE 10 11. REMOVE EXISTING UN -USED STORM DRAIN PIPE. 44621 LE=445.27 zl C4 co PIAI-AAG-F, H a8z +-X.X' H HEIGHT OF ROCKERY 2.0 Z9 Cm RI oe �,� *_._ - 12. SOILS EXCAVATED IN THIS AREA MAY CONTAIN HYDROCARBON +SE 450.0 ": ABANDON 64 IF 8" SD I al ODOR AND SHALL BE REUSED ON S17E IN COMPACTED FILL ABOVE + 2 + XXXX SE SWALE INVERT EL EXISTING CULVER­ TL=1.43% =1.40Yo 4' DIA. CMP DETEN71ON PIPES OR SOUTH OF BUILDING D UNDER C.� -u- �u� SEE NOTE 9 CL_ u V) 6'-0" TALL THE PARKING LOT. SURFACE DRAINAGE SWALE 00 -KUVIDE GRAVITY DRAINAGE _J 0 CEDAR FENCE L 13. CONTRACTOR SHALL COORDINATE WITH CITY INSPECTOR PRIOR 47 LF 8" SD IJ TO YARD DRAINS) SEE 4/C9 SL=1.437. TO PAINTING ALL CURBING AND PARKING AREAS WITHIN CITY Ln /y RIGHT OF WAY. PAVEMENT SLOPE DRAIN j -LANDSCAPE SETBACK �_l 0 YD 18" INSIDE DIA. YARD DRAIN VEGETATION STD DETAIL 410 - C3 BLD 44*7. ?6 B E (71. D MAINTAIN EXIS71NG BF E SW EL F E. 45.76 ,� q , - . -- - - _. I ! - - 1. 1 i 11 -,L ` -1 �7­_ -- . I Al 1'�AIL;r_ U 210 - I ­�j CB CATCH BASIN TYPE 1 8.0, CB 6 CALL 2 DAYS STD DETAIL 412IC9 RIM=4400 Z I - IE=49�30 EFORE YOU DIG B RIM= 152.20 F ROCKERY - SEE DETAIL I/C9 I U J 1-800-424-5555 45111 _j IE: + Ll -SIDE RI I G. (UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE) + 126 LF �:l SETBACk SOILS TEST PIT, GEOTECH YO 91 41 m CONSULTANTS, INC. Diii An IZ 850 1`4 Cal 8 int-r- 1 0.0 Lu d RIM=44 JLC 0 IP�447.80 C5 FOR T ,j IE4445. __1299- CONNEC71ON *.�8 3R" F 1, 2 f ,_j U-S Cl in 14 �l 5D TYPE 5 diURB RAMP 13 L I--- w W A=_ C4 7-- 2" ASPHALT CONIC PAVEMENT "B"OVER 12+00 84TH AVFNU 11+0 T 3�00 CLASS 12 12' ...... - ------ 4" MIN A TB + FIRE PROPOSED HIGH TRAFFIC LOAD DRIVEWAY' LANE SEE DWG. E 2.27.1 CIO BUS STOP� WITH TYPE 2 CURB RAMPS 4r 2 -4 J PROPOSED GRADE CUT -IN 10" PVC TO J-7; EXIS71NG CB ASPHALT TAPER 2" CSTC MIN IE=442.27 W BERM TO DRIVEWAY� IE=442.33 N 2" ACP CLB 4" A T8 RIM-448.52 RIM=448.64 RIM=448.76 -IE=443.20 IE=443.18 IE;=44.3%.I4:,--,. WATER LEVEL IN SYSTEM, R�LEA E RATE Q (Cfs) 2 YEAR EL 446.1111 XO.Q15. --YEAR,: E1­446 46:`:*�, J-0.10 ;460x- �`EL`44 0.38 RIM 447.56 if I IE=442.48 NS c) 5 LF 4" CMP c) NOTES: =0.5't 36 LF 10" P + CN 1. SUBGRADE SHALL BE PREPARED AS FOLLOWS: -1 CUT -IN 10" PVC IE=442.51 SL=0.40% nN I I qFrTinNq - rnmPArT rmppv nrpTiq or ra i Tn 1 112" R-,,,�, 4" DEPTH THROUGH JOINT #418" GALV ROD AT 30" O.C. TO EXISTING CB 95% MAX DY DENSITY PER STANDARD PROCTOR IE=442.33 N Bo PAINT URB* LOl#­__­_'_w__/ ----- 24" CMP MATCH p - 4�` EXIST IE=442.27 W - COMPACT UPPER 6" TO 9 N 0*38'38" r' \% r-1 10 TYP. EN71RE hL INVERT OF 48" CMP ON CUT SECTIONS 0 lu-A 95% MAX DRY DENSITY PER STANDARD PROCTOR MCA sp 140 LF 4' DIA CMP,, SL=0.5-Y. Lu IE=442 IL CB 10', 135-LF 4' DIA F_� 5 TYPICAL CROSS SECTION Lofvfp I E�> RIM=447.75 C) IE=40.78 -14: - _., " i I GISTV- 0 . ..... .. . Lol DRIVEWAY/ PARKING IONAL 9 A7 cd IE=442.57 SL=0.607. RIM=,d '701 QQ or" CB _A. V, NOT TO SCALE - --------- .............. N 0*38'38" E C6 lia RES OCTOBER 24, LIT_ NOTES: 1: ALL TYPE It CATCH BASINS SHALLHAVE A I SOLID LOCKING LIDS. APPROVED FOR CONSTRUCTION 2. CONNECT ALL ROOF DRAINS TO DOWNSPOUTS. BIJILDINUi 1.11-PI SEE ARCH PLANS FOR ROOF DRAIN LOCATIONS. L Vk CIfY ENGINEER DATE 3. F0071NG DRAINS SHALL BE CONTINUOUS AND SHAII BE CONNECTED TO SUMP PUMP SHOWN ON THIS PLAN. 0 10 20 40 SCALE. 1"-20P I z 0 Lr) r 1 C14 00 E- U) E- r4 cD 00 0) Z IZT4 Z :z Z z 16_� F-4 �D C) C14 Z 0 5 V) zl� V) F- LLI F- C14 Lo JOB NUMBER 01040 DESIGNED BY cs DRAWN BY EMC/JG CHECKED BY RDB/CS DATE 01/29/02 SHEET NUMBER C 3 4/fJ4/UZ U104U-(;J J:1,WM NOTES: 1. HYDRANTS MOST BE IN PLACE AND SERWCEABLE PRIOR TO COMBUSTIBLE CONSTRUCTION. Z FOUR FEET IS TO BE MAINTAINED BETWEEN FACE OF CURBS AND FIRE PROTECTION EQUIPMENT AND BETWEEN HYDRANTS, FIRE DEPARTMENT CONNECTIONS, AND POST INDICATOR VALVES. 3. A 4" STORZ ADAPTER IS REQUIRED FOR STEAMER PORTS ON ALL HYDRANTS INCLUDING EXISTING HYDRANTS. 4. WATER AND SEWER TO BE INSTALLED IN ACCORDANCE WITH OLYMPIC VIEW WATER AND SEWER DISTRICT STANDARDS. a FIRE PROTECTION ENGINEER TO PROVIDE CHECK VALVE ASSEMBLY (OCVA), RISER, FOC CONNECTION, CONTROL PANEL AND ALL OTHER NECESSARY APPURTENANCES. PROVIDE MONITORED VALVE AS REQUIRED BY OLYMPIC VIEW WATER AND SEWER. 6. FIRE DEPARTMENT CONNECTION (FOC) SHALL BE 4 INCH DIAMETER CONNEC11ON WITH SIAMESE 2 112 INCH DIAMETER HOSE CONNECTIONS. FOC SHALL INCLUDE CHECK VALVE, AND DRIP BALL VALVE. Z CPVC PIPE TO BE SIZED BY FIRE PROTECTION ENGINEER. 8. DOUBLE CHECK VALVE ASSEMBLY IS REQUIRED FOR ALL BUILDINGS WITH REMOTE READ. 9. PIPES SHOWN TO BE PLUGGED AND ABANDONED SHALL BE CUT AND PLUGGED WITH CLASS 3000 CONCRETE TWICE THE DIAMETER OF THE PIPE. END WALLS SHALL BE COMPLETELY REMOVED AND DISPOSED OF BY CONSTRACTOR. 10. PIPES DESIGNATED FOR REMOVAL SHALL BE COMPLETELY REMOVED AND DISPOSED OF BY THE CONTRACTOR. A.C. PIPE SHALL BE DISPOSED OF IN ACCORDANCE WITH PSAPCA REQUIREMENTS. 11. SEE LANDSCAPE PLANS FOR DCVA DETAILS. 12. POTHOLE EXIST. 10" WATERMAIN AT 236TH ST. SWI, AND EXIST. 12" WU AT 84TH AVE. W PREPARE CONNECTION PLAN, PROFILE, AND DETAILS. SECURE APPROVAL OF OLYMPIC V1EW` WATER AND SEWER DISTRICT AND POGGEMEYER DESIGN GROUP. 13. 8" WATERMAIN WILL 13E INSTALLED, TESTED AND APPROVED PRIOR TO CONNECTION TO EXISTING WATERMAIN. SEE DETAIL SHEET C14. 14. DEVELOPER SHALL ENTER INTO AN AGREEMENT WITH OLYMPIC WEW AND WATER SEWER DISTRICT. 15. OLYMPIC VIEW WATER DISTRICT SHALL CUT AND ABANDON EXISTING WATER SERIACE. CONTRACTOR WILL INSTALL WATER SERVICE PIPING AND METER SETTERS OLYMPIC V1EW` WATER AND SEWER DISTRICT WILL. 16. INSTALL 3" WATER SERWCE FROM SUPPLY LINE TO 2" METERS AND 3" BRANCH LINE FROM METER TO BUILDING. BOOSTER PUMPS MAY BE REQUIRED IN BUILDINGS DUE TO MINIMAL PRESSURE (35 PSI). 1Z ALL WATER AND SEWER REQUIREMENTS SHALL MEET OLYMPIC VIEW WATER AND SEWER DISTRICTS STANDARDS AND THE DEVELOPER SHALL ENTER INTO AN EXTENSION AGREEMENT WITH OLYMPIC V1EW AND WATER SEWER DISTRICT, 18. ALL TRENCH BACKFILL FOR UTILITIES ON 236TH ST. S.W. AND 84TH AVE. W. SHALL BE CONTROL DENSITY FILL PIPE BEDDING. THE CONTRACTOR SHALL CALL THE CITY OF EDMONDS INSPECTION LINE (425-771-0220, EXT. 1326) FOR ALL TRENCH AND PAVEMENT RESTORATION. LEGEND NEW WATERMAIN -W- EXIST. WATERMAIN - - EASEMENT '(::f FIRE HYDRANT (FH) tf FIRE DEPT CONNECTION (FDC) WATER METER CATE VALVE CALL 2 DAYS BEFORE YOU DIG 1-800-424-5M CA- r. ..... SE 449.7 1 vq 0 Z 2.5 H 2.5' H C ROX 7p, N N r, 7 C/) CIL c:) L&J (4- LL_j oi c1q 00 00 cv cn b v) m BLDG. A cl) I'm BF EL 446.76 IE=443.16-\ UL 6" SS SL=2 1. 7' H b VA CN 1 112 C IRR . r % 5 SMH T 1 012" ML TE RIM EL. 4 '061 3 IE=4 FIRE HYDRANT _ffE 7N I-8"x6* TEE MJ x FL Q!E 1-6" GATE VALVE FL x RJ THRUST BLOCKING 4t),.bl V,.J. 1 STA 11+50 4' DI WET -TAP CONNECTION TO 0 EXIST. 01 WATERMAIN ,SEE DETAIL SHEET C14 up! IZI 1�59 (j! -10 2.0' H PI Cl a +SE 450.0 2' METER CL 00 c V.A. BLDG. OF EL 447.2h 8.0, EXTERIOR TRPL REMOTE READ LOCATION L4 SE 450.0 C) 0 C) cs . ........ ........ . . ....... v. G S__ G ----------- A 't'lj� ......... . ........ . .... , ..... ............ OL... ........... 0 PAINT CURB YELLOW TYP. ENTIRE LENGTH .4 S 738'37E rn 00 00 30.00' c) N '38'38" ..... . ... ..... -- -- - ----- 6 .9­ 00 00 C/) m 2 v 71 BLDG. B BF EL 445.50 PIV 4" 01 4" EMERGENCY IE=44Z39 OVERFLOW TO SS WE NOW-44100 _=w-40-upm! -NO A --SEE + LB" DI WATERMAIN 312 LF X DI I $r�1911 FOC IE=444.16 ................... - vv C.) . .......................... . . . ........ . G DISCONNECT EXISTING I SERVICE FROM METER I LJLJ __j bi - L 99.95�% _ 0 LJJ UJ =( N 0-38'38- E $'Ira FOC 1 4p 114-1 Of 1 $�a 0 PIV 0. 4w DI FIRE HYDRANT 8w iss 1 S M TYPE 1 !V,6 1-8"x6* TEE Md x FL. R M L 44 7.90 1-6" GATE VALVE FL.x Rd IE=441.54 W THRUST BLOCKING SE R T T 90" NO u / I ODCA 16 6' SS SL=10%- BL D Sw EL BF f L 145.76 ,d - 450.3 EXTERIOR TRPL IE=441.42- - REMOTE READ /Y LOCA TION lot NT -I- - - - _r 2" METER w............ N...- w .............................................. . ......................... G 16' CAS EXST,_/ 12+00 84TH AVENUE WEST 13 owo %u �q u i 1 -1 u ij r (p s V\I�i ..... .... 0 LLJ __j CUT -IN NEW SSMH STATION 12+P9 ON EXISTING 8 SS IE=440.28 ± SEE SS MANHOLE CUT -IN ON SHEET C-13 m c) . ... . .... . . .... 'to +N 0 L . ...... . ....... - c : CN CX NOTE $1 A 111 : 1-8"x4" TEE Md x FL 1-4"x3" REDUCER MJ x IP 1-3" CATE VALVE Ip THRUST BLOCKING 4- STA 13+27 WET -TAP CONNECTION TO EXIST. DI WATERMAIN SEE DETAIL SHEET C14 wriR Aft A v on r us, d HE u IAPIC\\VWW WATE& PISTRICT B ....... -------------- Datei T 0 10 20 40 SCALE: 1 =20' HUILDINu oI P't', I EXPIRES OCTOBER 24, 200 r In z cn 0 0) I. -I � LO 00 E- U) co z z 0 z C-0 z (n cs z Z c):f U) C*4 C) Z 0 F_ 0 F_ rD cli u') 7/25/02,11:18 AM01040-05.plt 0 _0 qoL C 0 2122102 01040-05 8:20om 8. + -2.2' -H 0.0 0-) TYPE 5 CURB RAMP - 75 fG9 G 0 455 q c ( \le 0 E - -F- 4= 0(:6) Co 6 C) 0 W EL P 196' vv vv y y 11+00 3-, 12+00� 0 0 G) (D cn f-y 0-) 0-) 0 84TH AVENUE PROFILE SCALE. H l'--20' SCALE. V 1"-5' NEW CURB AND GUTTER TO MATCH ALIGNMENT OF EXISTING IMPROVEMENTS ON 84TH AVENUE *0� 0 U -0 c: 0- 1cf) I >1 co 0 0 Q) > --13 "o' -+--j C) 4 V 0 0 t . -1- > d� 0 (D 4-1 (D C: ?9.8 6? di I E 0- c- D -4- c c- 3: 0 -�-' 0 0 -jalm" F m 94 LF O'Sd SL=2%E' C-) El E G 12'"' SD w--l/ w w VERIFY EXIS71 IE=443.10 OR BELOW-""' n w SL = 0. 77. B4YH AVFNUE T 13+00 W - - - - - - - - w 1 14+00 IlDqdsV @ul-] jugwn (p n (9 9 6ON 1 a�v\inssv bUlADd �o a5p] m p p CNO qO dqo dqo HIGH TRAFFIC LOAD DPI WAY SEE DWG. E 227.1 C9 PAINT CURB YELLOW 10' NORTH OF AND >1 SOUTH OF DRIVEWAY > (D > A I - N 0 TE.- PARALLEL PARKING STRIPING TO BE INSTALLED IN 84TH AVE. W UNDER THIS CONTRACT. STRIPING TO BE COORDINATED WITH BUS STOP, AND CITY OF EDMONDS SPECIFICATIONS. lJ+uu 14+00 MATCH CURB OFFSET TO EXISTING IMPROVEMENT R/W ON 84TH AVE. WEST 22' (A 30' RDWY CIL 1.2'1 9.5'1 MATCH EXIST ASPH,* EXIST ASPH 20% 2" ASPH CONC CL 0 2" CRUSHED SURFACING TOP COURSE 6" CRUSHED SURFACING BASE COURSE BASE AS APPROVED BY ENGINEER. *SAW CUT. APPLY TACK COAT ROADWAY SECTION SCALE: 1"-5' 5.5' 6" IN DWY --:.12%- EAST R/W 2.;l st \—SEE PLAN FOR GRADES -CONC WALK PER EDMONDS SID DETAILS VERTICAL CURB & GUTTER PER EDMONDS STD DETAILS APPROVED FOR CONSTRUMON 0-2- CITY ENGINEER 66V-� It D. Bo WAS 0 21018 GISTS "'/ONAL EXPIRES OCTOBER 24, 2002 Wa'- . um, Q� Lu"i u, m Z Q::�qz-o 000 L, r= um, wz w < _j L" < > 0 V)o w :zmw w (n U-1 mz[::Zaf w 0 �-:D V) Z V) RZF-0 cx z U, '-J) 0 L L Lij L'.j Cl) 0 LL, z CL WZ Ip,-' z 2 z 0!;E (L g V) 5: 0 '- ui Lli Lj En S2 w mFn u.j fy- U) 0 lnr- 0 L0 I'D =>- �>m- z LLJ 0 M a:<M c' o C) CD - L(3' S�2 Ld LL- , 0 z 0:: LLJ iE- 0 0 0 Ck� La Q- Ui Z:g: (8) C) 0 0 uz w:i U-1 < 0 < vN:f o o' r= (Z) < ( a n LV'J) Z LLJ :2 :: Lij W o 2 Q-� 0 CL mo F- Kz< CL < Ld o 0< v) Ing <cnu- <n z Lo 0 0) C), u I I r- C4 03 E- Lo C14 U) El 04 0 Z C) z 2: Z < z 1-Z C\l �D C) 64 LLj Z F- 0 ZD cn F— V) LLJ Ld C) (o 04 Lr) u- 0 Ld Z) z Lli 00 BUILDII,ici ucri, JOB NUMBER 01040 DESIGNED BY cs ,DRAWN BY EMC/JG I CHECKED BY RDB/cs 00 < cf) < 0 0 ci) Q0 DATE 01/29/02 C5 7/25/02,11:21 AM01040-C6.plt c- -0 Ohp - e n,) on ss disk c- P� 4- ca INEW POLE LOCATION SSM —1092 0, Ohp urip Ohp, 01-1 W r ---- W rN 10+00S H-109A6-�Z,' im TYPE 5 n CURB RAMP Oh p '00111118e -All \0`1 452 RELOCATE OHP AND POLE� ABANDON EXISTING ��WT BY UTILff COMPANY-- PARKING 76' 7/ Driveway — t op uhp WE I I lk%lv gh PARKING 36' OT PO v23 6 TH S TR EE T- S W. S W, 12+00 Edge of pdving 12"Rcp HIGH TRAFFIC LOAD DRIVEWAY SEE DWG. E 2.27.1 C10 S 887051 " E ABANDON EXISTING CULVERT wml� WE 74vlr? 41 1 �j NEW CURB AND GUTTER TO MATCH ALIGNMENT OF EXISTING IMPROVEMENTS ON 236TH STREET /-� EXIS71NG ROAD -1 —Ohp unp Ohp — 11L .748 i—A G Asphalt 14E�XISRN�GCB 0 :r 7D —u �NV Kh p — 0 h p ---- ------- - A Jf 450 F T­ 450 'E 445 J, L 445 10- NI I ONTER 1 RQ I ADWAY 1 - ------ . . . . . . 4410 7- 440 10+00 11+00 12+00 236TH STREET PROFILE SCALE: H 1"-20' SCALE: V 1�-5' VOTES: 1. EXIST U71LITIES MAY HAVE TO BE RELOCATED. VERIFY LOCATION PRIOR TO CONSTRUC71ON AND NOTIFY ENGINEER or ANY CONFLICTS. 2. PARALLEL PARKING STRIPING TO BE INSTALLED ON 236TH STREET TO CITY OF EDMONDS SPECIFICATIONS. RDWY CA 13+00 14+00 RIW (A 4.8'± 1 5.5± MATCH CURB OFFSET TO EXISTING IMPROVEMENT. AND CB ON 236TH ST 19'± 30' 5.5' EAST RIW 3.5'1 6" IN MATCH DWY EXIST ASPH* EXIST ASPH 27.± 2.0% 0. j Q SEE PLAN FOR GRADES 2" ASPH CONG CL 6 to CONC WALK PER 2" CRUSHED SURFACING TOP COURSE EDMONDS STD DETAILS 6" CRUSHED SURFACING BASE COURSE VERTICAL CURB & BASE AS APPROVED BY ENGINEER *SAW CUT GUTTER PER EDMONDS APPLY TACK COAT SM DETAILS ROADWAY SECTION, SCALE. 1"=5' APPROVED FOR CONSTRUCTION F -L- DATE J BUILDIN(3 UEP I 0. B0 of WAS&, 21018 GISTE 'SS��%NAL EXPIRES OCTOBER 24 u, 0-- Ld � vlomm� id-Z Uzi < 000W M F= m Ld cn 0 Ld Lu L' 5 0,0 V) 0 ML, W 'm W m m Z' W- 2 �- D V) Z V) Z - 0 z ui Qx- n LX, 0 0 W 2 W :2 :2 � : F- �0'- :� z 0 W, V) 0 E0 F- LLI �- 30 Ld >- CD >= z i < 0 I<,- cor-, , -- m, m< c) Q:� -i W 0 F- u- ::) 0 IL LL- fk'- W UO U05 LZIJ x C) <C-)C)zo LLI Z < z W C) OZ:2�61 >- (1f r= C) Ld CO LLI 0 < ':: V) z - MLu:D00 W 0 -:7 - >- z < (f) Zz<,-- < 0- < 0 >- cr Lij Z >- 0 n V) <'m L- < D LO z cr) 0 a) L0 U) C4 00 9� cq r-) El 'C':)- 04 0,0 0 Z CD z F- CD F4 z V) ;E ci Z: ct-1 E-4 �4 �D 04 C) cli 0 :3 c/) F� (D cn 1.1 LLJ ct� Lu E 0 ::D 00 ry CL Ljj ui < n, V) ry Q0 JOB NUMBER 01040 DESIGNED BY cs DRAWN BY EMC/JG CHECKED BY RDB/CS DATE 01/29/02 SHEET NUMBER C6 16" MAX #4 BARS AT 6" SPACWG 4" MIN 4 24" DIA HOLE C,4 2- (TYP) L - - - m . . F I" MIN . .41.� 2 112" MAX 48 1 112- PVC SCHEDULE 40 ASTM D 1785- ANCHORED TO CONC. 2-SS EXPANSION ANCHORS - FLOAT SWITCH JUNCTION BOX FINAL GRADE-, 1 112" PVC SCHEDULE 40 1 112" 90' FL ELB GASKET JOINT RESTRAIN TO CB WA TER LINE WITWO 112- RODS TO CB 3 4" PVC HIGH LEVEL ALARM EL 441.60 LAG PUMP ON EL 441.20 LEAD PUMP ON EL 440.50 1 112- PIPE FLOAT SWITCH, TYP SEE NOTE 5 PUMP OFF EL = 439.5 1 112" 90' FL ELB BALL VALVE--" SUBMERSIBLE PUMP SEE NOTE 1 Z1. X C14 6" 4 POLYPROPLYNENE STEPS-< 12" (TYP) I" MIN - 2 112" MAX SEPARATE CAST IN PLACE BASE GRAVEL BACKFILL FOR PIPE ZONE BEDDING 1 112" COUPLING I I m mix NEENAH PREMA-GRIP LID SURFACE ADA COMPLIANT MANHOLE RING AND COVER RECTANGULAR ADJUSTMENT SECTION OR CIRCULAR ADJUSTMENT SECTION FLAT SLAB TOP STEEL 6 V F. i� 1 -6 PRECAST BASE W1 TH IN TEGRAL RISER "0" RING 6" 12 SEPARATE PRECAST BASE NOTE&- 1. NO STEPS ARE REQUIRED WHEN HEIGH T IS 4' OR LESS. 2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE ROUNDED. 3. FRAME AND GRATE MAY BE INSTALLED WITH FLANGE DOWN OR CAST INTO ADJUSTMENT SECTION. 4. GROUT ALL JOINTS INSIDE AND OUTSIDE 5. MINIMUM DISTANCE BETWEEN KNOCKOUTSIS 8 2 BASE REINFORCING STEEL IN IFT IN EACH DIRECTION INTEGRAL BASE SEPARATE BASE 0.15 0.23 4 CA TCH BASIN TYPE 2 NOT TO SCALE C8 2" EL. CONDUIT TO EL. CONTROL PANEL SUBMERSIBLE PUMP > < 'CO TYPE 2 SEE 4/C8 PUMP MOTOR CONTROL PANEL WALL MOUNT IN ELECTRICAL ROOM ,-MOTOR DISCONNECTS EL 449.42 4" DIA CO SEE 41C8 7 IA- fl 314" CONDUIT WIWATER TIGHT _4" BACK STRAIN RELIEF CORD GRIP, TYP WATER VALVE 4"0 EMERGENCY OVERFLOW TO SO EL, 444.33' 6"0 PIPES FROM YARD DRAINS '**-CO TYPE 2 IE 443.7 N IE 441.60 E SEE 41C8 IE 442.35 S ---GUIDE RAIL SYSTEM HYDR-O-GUIDE OR EQUAL -4- 318" GALV LIFTING CHAIN ___--POLYPROPLENE STEP, TYP 2" 90' FL ELB BALL CHECK VALVE --f J IE 438.5 STORMWATER SUMP PUMP - NOT TO SCALE A r_1 3" STYROFOAM MAT DIAGONAL BARS PER PIAN� ASPHALT LOAD TRANSFER SLAB PAVEMENT --- (SEE DETAIL ABOVE), Lo CMP AND APPURTENANCES 14 GAUGE, 0.79 INCHES, (3'xl-) CORRUGATION GALVANIZED AASHTO M274 JOIN TWIN 48" CMP PIPES W1 24" CMP LINK AT INVERT EACH END SUMP PUMP NO TES: 1. PUMP SHALL BE SUBMERSIBLE CENTRIFUGAL WITH NON -CLOGGING IMPELLER DESIGNED TO PASS 314" SOLIDS. BASE, MOTOR AND PUMP HOUSING SHALL BE STAINLESS STEEL OR CAST IRON W1 STAINLESS STEEL HARDWARE. MOTOR SHALL BE 0.30 HP, 115 VAC, I PH, 60 H2, OIL FILLED. EACH PUMP MOTOR SHALL HAVE A CONTROL PANEL MOUNTED STARTER AND SHALL HAVE AUTOMATIC THERMAL OVERLOAD PROTECTION. SHAFT SEAL SHALL BE MECHANICAL WITH CARBON AND CERAMIC FACES. PUMP SHALL HAVE A MINIMUM DISCHARGE RATE OF 32 GPM AT 12' TDH, MODEL SHEF 30 AS MANUFACTURED BY HYDROMATIC OR APPROVED EQUAL. 2. ALL PVC DISCHARGE PIPE AND FITTINGS SHALL BE FLANGED 3. BALL VALVE SHALL BE BRONZE BODIED, FULL PORT, NON -SHOCK RATED AT 100 PSI AT 73. WATER. 4. SWING CHECK VALVE SHALL BE RESTRAINED, SCREWED OR FLANGED CONNECTIONS, NON -SHOCK RATED AT 100 PSI. 5. FLOAT SWITCHES SHALL BE NON -ARCING SPOT MERCURY SWITCH IN A HERMETICALLY SEALED POLYPROPYLENE CASE, WITH WEIGHTED CORD #2900 AS MANUFACTURED BY 6ONERY MFG., INC. OR EQUAL. 6. ALL ELECTRICAL WORK SHALL COMPLY NTH THE NEC AND LOCAL CODES. SEE ELECTRICAL PLANS FOR WIRE, CONDUIT, AND CONNECTIONS. STAND BY GENERATOR TO BE PROVIDED ON -SITE. 7. THE PUMP CONTROL PANEL SHALL INCLUDE A MAIN POWER BREAKER, A POWER BREAKER FOR EACH PUMP MOTOR, POWER BREAKER FOR FLOAT LEVEL CONTROLS, MOTOR STARTER FOR EACH PUMP, FLOAT CONTROL RELAYS, A "HAND -OFF -AUTO" SELECTOR SWITCH FOR EACH PUMP, A TWO STEP ELECTRONIC ALTERNATOR WITH SEQUENCE SWITCH FOR LEAD -LAG PUMP ALTERNATION, FAULT RESET PUSHBUTTON, VISIBLE AND AUDIBLE ALARM WIALARM SILENCE RELAY TO INDICATE H13H WATER LEVEL. PUMP CONTROLS SHALL BE A MAXIMUM OF 115VAC. THE "HAND- OFF- AUTO" SELECTCR SWITCH SHALL "HAND" POSITION TO AUTOMATICALLY RETURN TO "OFF" WHEN HAND BE SPRING LOADED IN THE PRESSURE IS RELEASED. IN THE "AUTO" POSITION, STARTING AND STOPPING OF EACH PUMP SHALL BE CONTROLLED AUTOMATICALLY BY THE PUMP TANK FLOAT SWITCHFS. IN THE '"HAND" POSITION THE PUMP WILL RUN CONTINUOUSLY REGARDLESS OF THE WATER LEVEL IN THE TANK. THE CONTRACTOR 3HALL SUBMI T SHOP DRAWINGS TO THE ENGINEER FOR PUMPS AND ALL CONTROL COMPONENTS. 8. INSTALL BACKWATER VALVE ON EMERGENCY OVERFLOW PIPE, CHECK VALVE SHALL BE PVC WITH QUICK ACTION, EASILY REPLACEABLE FLAPPER WITH ELASTOMERIC SEAT CHECK VALVE SHALL BE #675P AS MANUFACTURED BY NOS, OR EQUAL. 10" LOAD TRANSFER SLAB F t%l A r% 'rVIMr* A A A I It �M A. MANHOLE I. WELDED JOINTS TO BE WATER TIGH T 2. ALL STEEL PARTS SHALL BE GALVANIZED & COATED W1 ASPH PER TREA TMEN T 1. 3. ORIFICE SHALL BE SHARP EDGE, SHOP DRILLED. DISCHARGE CON TROL FLOW CONTROL MANHOLE PIPE DIA TO 1A TCH OUTLET PIPE 3's NON-SHRINK'GROUT 12 MAX OUTLET PIPE 8 I Z�-FLEXIBLE ADAPTER COUPLING '2" 8- FMAX GASKET (TYP) \� SLEEVE COUPLING CNL- I --\\\-10" DIA REMOVEABLE COUPLING ORIFICE ORIFICE PLA TE Connection And Control Device NO SCALE 5/8" SS EPDXY ANCHOR BOLT I" DIA SS PIPE SPACER (-1/4"XI.5" SS STRAP MH WALL Pipe Support NO SCALE AND TEE D. B0 0� WAS 21018 _10, GIST ONAL EXPIRES OCTOBER 24, NEENAH R-1877-El FRAME DOUBLE LID OR EQUAL 24" 48* OPENING FRAME AND COVER EL 448.60 RIM EL. 447.56 OVERFLOW 446.48 6" INSIDE DIAMETER LIFT ROD AS SPEC. BY MFR. W1 HANDLE EXTENDING TO WITHIN ONE FT. OF COVER AND ADJUSTABLE HOODLOCK FASTENED TO FRAME OR UPPER HANDHOLE. 8" OUT 442.48 5/80 DIA ORIFICE 5 1-0" POLYPROPYLENE STEPS SECTION STRUCTURE NOT TO SCAT OVERFLOW 446.62 DEAD PC 444.48 _%j IPE SUPPORT V' DIA ELBOW Y/ ORIFICE 118' DIA ORIFICE OUTFALL Ow REMOVEABLE E! 'OUPLIN N q It EMPORARY EROSIOi\j CONTROL NOT 70 SCALE WET VAULT STRUCTURE DETAIL T SHEAR CATE z LO C" Cn LO I co E- , LO C*4 :V1 E-- q4 n 23 2,0, 0 z ;z 0 C-9 Z z < z ck: --- q > co C14 CD C14 Z 0 wi 5 V) C3 V) C .13 LU U: F- V) m F- LO 7/25/02, 01:44 PM01 040-C9.pit GEOTEXTILE 4 TO 6 IN. QUARRY SPALLS PROVIDE SWALE, GRADE TO DRAIN TO APPROVED SYSTEM. 12 IN. OF COMPACTED SOIL OVER GEOTEXTILE. SLOPE TO DRAIN 6 MAX. HEIGHT 4 FEET MINIMUM 4-IN DIA. PERFORATED 2 BASE COURSE RIGID PIPE (HDPE TRIPLE WALL OR BETTER). SLOPE TO DRAIN VR 1 FT. WHICHEVER lid IS GREATER. AND CONNECT TO STORM DRAIN SYSTEM. PROVIDE CLEANOUTS. COMPACTED 9- - r3= 11 �]jl GRANULAR 2% SLOPE BASE NOTES: 1. CAN FOR CLEAR AND GRADE INSPECTION PRIOR TO BASE COURSE BEING PLACED. VERIFICATION OF ROCKERY HEIGHT, FOUNDATION MATERIAL, AND ROCK SIZE BY CITY CLEARING AND GRADING INSPECTOR IS REQUIRED. 2. QUARRY SPALLS AND CRUSHED ROCK SHALL BE PLACED DIRECTLY FROM TRUCK OR OTHER SUITABLE CONTAINER IN ORDER TO MAINTAIN CLEAN BACKFILL. 3. ALL ROCKERIES OVER 30-IN IN HEIGHT ARE CONSIDERED A STRUCTURE PER THE LAND USE CODE AND MUST BE LOCATED OUTSIDE OF ALL STRUCTURE SETBACK LINES. 4. OPENINGS SHALL BECHINKED WITH QUARRY SPALLS. 5. ROCKERIES GREATER THAN 4-FEET IN HEIGHT SHALL BE DESIGNED BY A CIVIL OR GEOTECHNICAL ENGINEER. 6. ROCKERIES CONSTRUCTED IN THE RIGHT-OF-WAY ARE SUBJECT TO TRANSPORTATION DEPARTMENT DEVELOPMENT STANDARDS. EL 445.17' ROCKERY 0. 78' 450' TOP EL 447.88' 446.62' J RETAINING WALL 'b NOT TO SCALE MAX 2.82 MIN 2.16 0# 6.0 8" SEE DETAIL THIS SHEET IAI I A WALL A 440' BIOFILTRA71ON SWALE PLANTS SEE TABLE 30.00' MAX EL 448.42 MIN EL 447.76 15" MIN COVER 48" D IA 3.50' WALL B 4.00' 6.00' 2" COMPOST TILLED INTO 6" NATIVE SOIL PLANT SPECIES SEE TABLE SEED AT lIb PER 100 SF 0. 047. SLOPE 3 ROAD 11.50' 00, 8.00' 2. 48" VIA r48" DIA D /0.5% - - - 4.00' 6. 00' 5.00' SECTION SCALE 1 5' 0.25' 10.00' APPROX EXIST 11 GRADE EL 445.17 EXIST. 12" CONC. CULVERT LTRATION SWALE PROF NOT TO SCALE ILE EL 444.67' lb >< C'i 'b 0.5' AT WALL A 1.0' AT WAI I B RESTORE EXIS71NG FENCE TO ORIGINAL CONDITION -L0 ci 0.78' 2 CLEAR 2" CLEAR 5P C-4 (2)J4 CONC 3000 psi AT 28 DAYS REBAR ASN GRADE 60 j4H AT 16- WALL ISOLATIOH JOINTS AT 25' O.0 #5 AT 18- BACKER ROD AND CAULKING b #4 AT 18- (3)#4 T & B u� ----a \,7 ',Z4 3.50' 3 COMPETENT SOIL CLEAR 2000 PSF BRG DENSE NA71VE MATERIAL OR 95% ASTM D-1157 RETAINING WALL 3-10 MIN. GRADE 0.5% SCALE I 3-10 F_ MIN DEPTH 3" \-MIN ELEVATION AT YARD DRAIN OR CB RIM SURFACE DRAINAGE SWALE DETAIL NOT TO SCALE B10FILTRATION SWALE PLANT TABLE FINELY -TEXTURED PLANTS TOLERANT OF FREQUENT SATURATED SOIL CONDITIONS OR STANDING WATER 60-70 PERCENT TALL FESCUE 10-15 PERCENT SEASIDE CREEPING BENTGRASS OR COLONIAL BENTGRASS A. TENIUS OR CAPILLARIS 10-15 PERCENT WATER FOXTAIL ALOPECURUS GENICULATUS 6-10PERCENT ALSIKE CLOVER 1-5PERCENT MARSHFIELD BIG TREFOIL 1-6 PERCENT REDTOP A. ALBA OR GIGANTEA A WETLAND SEED MIX MAY BE APPLIED BY HYDROSEEDING, BUT IF COVERAGE IS POOR, PLANTING OF ROOTSTOCK OR NURSERY STOCK IS REQUIRED. POOR COVERAGE IS CONSIDERED TO BE MORE THAN 30 PERCENT BARE AREA THROUGH THE UPPER 213'OF THE SWALE AMR FOUR WEEKS. FRAME AND GRATE, PER DETAILS, 422 OR 425 OR FRAME W/SOLID COVER. NOTES 1 AS AN ACCEPTABLE ALTERNATE TO REBAR, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. WIRE MESH SHALL NOT BE PLACED IN KNOCKOUTS. 2 THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20". KNOCKOUTS SHALL HAVE A WALL THICK ESS OF 2" MINIMUM TO 2 1/2" MAXIMUM. 3 THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE PIPE INVERT SHALL BE 5'. 4 FRAME AND GRATE MAY BE INSTALLED WITH FLANGE DOWN OR CAST INTO ADJUSTMENT SECTION. 5 THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR AND THE WALLS MAY BE SLOPED AT A RATE OF 1:24 OR STEEPER. 6 OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BAS UNIT. 7 THE 6" ADJUSTMENT SECTION SHALL HAVE ONE #3 BAR CENTERED. THE 12" ADJUSTMENT SECTION SHALL RECTANGULAR ADJUSTMENT SECTION HAVE TWO #3 BAR EQUALY SPACED. 8 GROUT ALL JOINTS INSIDE AND OUTSIDE. #3 BAR EACH CORNER #3 BAR EACH SIDE #3 BAR EACH WAY CATCH BASIN AND ALL REINFORCING STEEL TO CONFORM TO WSDOT STANDARD PLAN B-1 6 PRECAST BASE SECTION CATCH BASIN TYPE 1 412 Revision Date Oct, 2000 6" SD - - - - - - - -- -- - --- - - - - E_j__ 10' SD STUB 0' PRIVATE (TYF. SID EASEMENT 0- EASEMENT LINE 0 10' PRIVATE SD EASEMENTF� I 0 'I IL U) 0 SIDEWALK AND CURB STREET CATCH BASIN ,—YARD DRAIN W/SOLID COVER n_ ................ o U) I YARD DRAIN STUB OUT FOR ROOF-----__ (TYP.) AND FOOTING DRAIN CONNECTIONS (TYP.) '<� ------------- LOT LINE (WP.) R—O—W NOTE SPECIAL CAST YARD DRAIN MAY BE REQUIRED FOR --------- MULTIPLE PIPE CONNECTIONS. DETAIL NOTES 4 YARD DRAINS TO BE CONSTRUCTED FROM CONCRETE PIPE, IN ACCORDANCE WITH ASTM C 14 UNLESS OTHERWISE SHOWN ON THE PLANS OR NOTED IN THE SPECIFICATIONS. CUTOUT HOLE SIZE EQUAL TO OUTLET PIPE OUTSIDE DIAMETER PLUS YARD DRAIN WALL THICKNESS. CONNECTION TO OUTLET PIPE TO BE MORTARED AND Q < MADE FLUSH WITH INSIDE OF THE YARD DRAIN WALL. CAST IRON BELL GRATE. FITS INTO BELL RECESS AND EXTENDS FLUSH WITH FACE OF BELL. THE GRATE SHALL HAVE SLOTS (HOLES) THAT CONSITUTE 50 PERCENT OPEN NREN FoR DRj\j"NGF. )NLET BEI_L SURFACE SHALL BE FINISHED TO ASSURE NON — ROCKING FIT WITH ANY COVER. CONCRETE A IN. MIN. 12" OR 18" CONNECT TO CITY OWNED MAINTAINED SID SYSTEM IN THE STREET. UP TO 5 CONNECTIONS PER SERVICE LINE. YARD DRAIN - r r F 410 Revision Date Oct, 2000 Qr_ D. B0 y WAS . . t 0 21 is 43� 01 S/ONAL FEXPIRES OCTOBER 24, 200 0 Lr) m C) 9ZI co E- CO LO C14 E- 04 0c, C> z z C) Cn < < E­4 �4 Cn C:) C14 Z 5 C) 00 Ld CD 2 4 01040-C9 9. OOAM 7/25/02, 08:33 AM01040-CIO.Pit =m FILTER FABRIC - SECURED TO 2' X 2' 14 GA. WIRE FABRIC EQUAL 2' X 2' WOOD OR C> EQUIVALENT I I I �u 8'- 12, u E� PLACE 3/40-1,5' WASHED GRAVEL IN THE TRENCH AND ON BOTH SIDES OF FILTER FABRIC FENCE ON THE SURFACE. %t �j FILTER FABRIC MATERIAL IN CONTINOUS ROLLS. USE STAPLES OR WIRE RINGS TO ATTACH FABRIC TO WIRE. WIRE MESH SUPPORT FE141�E TO SUPPORT FILTER FA IC. M Mom.. I I I I i m-;; I fim;-" ME B BURY BOTTOM OF FILTER - ��- �9 -1 2# MATERIAL 8' TO I 6' MAX. u Ll\ 2' X 2' WOOD POSTS OR EQUIVALENT CONTRACTOR/DE V ELOPER SHALL MAINTAIN AND REPLACE STRAW BALES TO INSURE PROPER EROSION CONTROL, , 090- 1 9ww CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN, YI REVISIONS STANDARD DETAIL APPROVED SY DATE FILTER FABRIC FENCE FILTRATION SYSTEMS i DATE 7/24/01 . I SCALE NTS I DWG No' E1.1 BINDING WIRE OR n EXCAVATE TRENCH 8" DEEP TWINE WHERE STRAW BALES WILL I C BE PLACED AND STAKE BALES, COMPACTED SOIL T PREVENT PIPING so W-0 CROSS SECTION OF A PROPERLY INSTALLED STRAW BALE BARRIER TWO STAKES PER BALE TO MAINTAIN POSITION STRAW BALES AS REQUIRED, Im PROPER PLACEMENT OF STRAW BALE BARRIER IN A DRAINAGE WAY CONTRACTOR /DEVELOPER SHALL MAINTAIN AND REPLACE STRAW BALES TO INSURE PROPER EROSION CONTROL, CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN. REVISIONS APPFMVED SY DATE STANDARD DETAIL STRAW BALE DAM FILTRATION SYSTEMS DATE SCALE DWG NO. ilooi-lgso 7/24/0 NTS I E1.11.1 -7 /0# 15rlC%L/ FABRIC 15 '4 ks y 'N % ; oo* oo L Ali. A CATCH BASIN nN, 14rl; 4A An PLACE FILTER FABRIC BETWEEN FRAME AND GRATE, PLACE 7/8' WASHED GRAVEL 3-4 INCHES HIGH AROUND CATCH BASIN TO FILTER WATER. STRAW BALES MAY BE USED IN CERTAIN CIRCUMSTANCES (SEE DETAIL E111) UPON APPROVAL OF CITY ENGINEER OR HIS REPRESENTATIVE, THIS APPLICATION SHALL BE MAINTAINED AT ALL TIMES DURING CONTRUCTION PERIOD. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL MEASURES BEFORE WORK CAN BEGIN. NA * 0 N. 'D C.1-T-Y'... -0.-F: ----'--E--D: REVISIONS STANDAR D DETAIL AMmy'n- BY PATE TEMPORARY SEDUENT TRAP FOR CATCH BASINS leg *0- . 99() DATE 7/24/01 FSFALE NTS IDWG No' E1.3 '-Vloo- -14�m 4 'p I MIN. RADIUS -4'-8' QUARRY SPALLS- 8'-12' MIN. DEPTH PROVIDE FULL WIDTH OF INGRESS/ EGRESS AREA CONTRACTOR SHALL MAINTAIN TEMPORARY CONSTRUCTION ENTRANCE DURING THE CONSTRUCTION PERIOD. CITY INSPECTION REQUIRED ON ALL EROSION CONTRO MEASURES BEFORE WORK CAN BEGIN, 4F 0,90— 1 99v ..--C.-l-T-Y... -0-F.*:.,.......E.-D-N�'�0-'N.'D..-S-....*:.....''* REVISIONS STAN DAR D DETAIL APPROVED BY DATE STABLIZED COUSTRUCTION ENTRANCE DATE 7/24/01 1 SCALE NTS I DWG NO. E1.2 N (u CITY INSPECTION REQUIRED ON FORM WORK PRIOR TO POUR 5-1/2' 7-41 1' BATTER A l'R A 0.05 FT/FT -4 A 4 A 4'. 6. 4 A 4 4* A 4 18' STANDARD 24' ARTERIAL NOTESi 1. FORMS SHALL BE TRUE TO LINE AND GRADE AND SECURELY STAKED, 2. THRU JOINTS SHALL BE PLACED ADJACENT TO CATCH BASINS, 3. EXPANSION JOINTS SHALL BE EVERY 10 FEET AND DUMMY JOINTS EVERY 5 FEET, 4. THRU JOINTS SHALL HAVE 1/2' TO 5/8' WIDE PREMOLDED JOINT FILLER. 5. CONCRETE SHALL BE CLASS 3- 300OPSI. 6. FINISH SHALL BE LIGHT BROOM, 7. CURB SHALL BE SPRAYED WITH CLEAR CURING COMPOUND OR SHALL BE COVERED AND KEPT MOIST FOR 72 HOURS, 8. ALL SIDEWALKS POURED BEHIND CURB IN DRIVEWAY AREAS SHALL BE 6' THICK OVER 2' OF CSTC WITH SUBGRADE COMPACTED TO 95% MAXIMUM DENSITY. F- .%-E.- D: NA-0. REVISIONS APPROVED BY DATE STANDARD DETAIL STANDARD TY PE "A" CURB/GUTTER DETAIL DArt. 7/24/01 Tiam NTS IDWG NO. E2.8. CONCRETE CURB AND GUTTER OR 16' VERTICAL CURB (TO MATCH PER EXISTING CURBING) SHALL EXTEND _2ARIES TO END OF RADIUS, CODE EXTRUDED CURB SHALL START AT END OF RADIUS RADIUS VARIES ,TRANSITION SLOPE SHALL w BE 1110 (TYP) TYPE 2 CURB RAMP TYPE 1 CURB RAMP 5' LONG RAMP MIN. 5' LONG RAMP MIN. (SEE DETAIL E-2.1 Ld (SEE DETAIL E-2,14) Ld SIDEWALK, m u Lin z o I r U \PI ACE 1' WIDE TACTILE Afj V BEHIND START OF RAMP CONCRETE CURB AND GUTTER PLACE FULL DEPTH EXPANSION JOINT /.fBF CONCRETE GUTTER BETWEEN C/G AND HIGH TRAFFIC LOAD GUTTER, WING AND C/G ARE NOT POURED AS ONE UNIT CURB/GUTTER AND WING FOR HIGH TRAFFIC LOAD GUTTER MAY BE POURED AS ONE UNIT. FULL DEPTH EXPANSION JOINTS SHALL BE PLACED IF WIDTH OF OPENING EXCEEDS 15', Est. 1891D REVISIONS STANDARD DETAIL APPROVED BY DATE HIGH TRAFFIC LOAD DRIVEWAY ACCESS (WITH CONCRETE DRIVEWAY APPROACH) DATE 7/24/01 SCALE NTS IDWG NO E2.27.1 MEN= Lo z ml co I r- CD r:� 00 r)---"o E- co Lo E- C4 P4 cO 0 z Z z V) FZ < z E--i c:) C4 F-4 0 LLj I-- Z:) U) M 0 V) C-D LLJ Ld Of U) to C\l Lo 1115102 01040-CIO 11:54am m 1-111111 r)lt%li:: f li P i 7/25/02, 08:32 AMO I 040-C 11. pit REMOVE AND REPLACE CURB AND GUTTER L CITY INSPECTION REQUIRED ON FORM WORK PRIOR TO POUR. ACCESSIBLE RAMP SHALL BE POURED SEPARATELY FROM CURB AND GUTTER, NEW CURB AND GUTTER INSTALL 1/2' EXPANSION JOINT MATERIAL (TYPICAL) kP L_L_ �-j /0, L L-"L I L -1 1 - '_LLL LLV I LLL\L ' I _LLL TRACTION GI JD L 1+ SEE RAMP D -TAIL 'LLLLLL L L\ TRACTION G ID L S EE RAMP TAIL W # I D G E2 DWG # E2. 4 LL SIDE RAMP D 10 <TY 10 <TYPICAL) EXIST SIDEWALK Ld V) C4 x w SAW CUT AS REQUIRED TACTILE WARNING STRIP (TYPICAL) AW CUT AS REQUIRED NOTE, 1. AT LOCATIONS WHERE NEW RAMPS ABUTT EXISTING CURB, GUTTERS, PLANTER STRIPS, AND SIDEWALKS, CONSTRUCT NEW RAMPS TO MATCH ADJACENT SURFACES, 2. ALL CONCRETE SURFACES SHALL HAVE A BROOM FINISH. 3. CONCRETE SHALL BE SPRAYED WITH A CLEAR CURING COMPOUND OR SHALL BE COVERED AND KEPT MOIST FOR 72 HOURS, V, REVISIONS APPROVED BY DATE STANDARD DETAIL CURB RAMP TYPE 4 DATE 7/24/0, SCAM NTS DWO NO. E2.17 lac ISF90-1 9,90 CITY INS ECTION REQUIRED ON FORM WORK PRIOR TO POUR V R I' BATTER 4 I'R A 0.05 FT/FT A. - -1 A -4 14 .A 6' .4 A Id 18' STANDARD 24' ARTERIAL NOTES, 1. FORMS SHALL BE TRUE TO LINE AND GRADE AND SECURELY STAKED. 2. THRU JOINTS SHALL BE PLACED ADJACENT TO CATCH BASINS, 3. EXPANSION JOINTS SHALL BE EVERY 10 FEET AND DUMMY JOINTS EVERY 5 FEET, 4, THRU JOINTS SHALL HAVE 1/2' TO 5/8' WIDE PREMOLDED JOINT FILLER, 5. CONCRETE SHALL BE CLASS 3- 300OPSI, 6. FINISH SHALL BE LIGHT BROOM, 7. CURB SHALL BE SPRAYED WITH CLEAR CURING COMPOUND OR SHALL BE COVERED AND KEPT MOIST FOR 72 HOURS, 8, ALL SIDEWALKS POURED BEHIND CURB IN DRIVEWAY AREAS SHALL BE 6' THICK OVER 2' OF CSTC WITH SUBGRADE COMPACTED TO 95% MAXIMUM DENSITY. CITY'.. 0 ..0 N'D S REVISIONS - STANDARD DETAIL APPROVED BY DATE STANDARD TYPE "A" CURB/GUTTER DETAIL DATE SCALE DWG NO. 7/24/01 NTS E2.8 CITY INSPECTION REQUIRED ON F`DRM WORK PRIUR To POUR ACCESSIBLE RAMP SHALL BE POURED SEPARATELY FROM CURB AND GUTTER. REMOVE AND REPLACE CURB AND GUTTER LLLI LLL' L LLLI 11 L LLL L L %Pl LL L L L L_ L L L -LLLLL L SIDE RAMP DIO (TYPICAU SAW CUT OR REMOVE TO NEAREST JMNT EXIST 5' SIDEWALK N1/2' EXPANSION J13INT '-0' TACTILE STRIP TRACTION GRID SEE RAMP DETAIL DWG# E2.25 6' CONC CURBING SHALL EXTEND T13 -LLLLLLL THE LIMITS OF THE SIDE SLOPE AND SHALL MATCH THE TOP OF THE SIDEWALK SAWCUT AS REQUIRED EXIST 5' SIDEWALK NOTE: 1. AT LOCATIONS WHERE NEW RAMPS ABUTT EXISTING CURB, GUTTERS, PLANTER STRIPS, AND SIDEWALKS, CONSTRUCT NEW RAMPS TO MATCH ADJACENT SURFACES, 2.ALL CONCRETE SURFACES SHALL HAVE A BROOM FINISI, 3.CONCRETE SHALL BE SPRAYED WITH A CLEAR CURING COMPOUND OR SHALL BE COVERED AND KEPT MOIST FOR 72 HOURS, - C' REVISIONS APPPnVrn lly DATE STANDARD DETAIL CURB RAMP TYPE 5 DATE SCALE DWO NO. E2.18 7/24/01 NTS CITY INSPECTION REQUIRED ON FORM WORK PRIOR TQ.POUR EXPANSION JOINT DUMMY JOINT z 'A A% A A. .:A A A4 A 04. 4' '4 A A Aa 1* 4 . .... 1 - . .4. A A.. ..x 4 A tA A A 4 '7 '4 A. I A: A A A 4 A. I A 4. .-A A A 'A. 10, O.C. 5' O.0 PLAN 5' TO 7/ A 4 A' A I %'A - - - . . V.. A A - - DA A:* A 4 11A. .. IV E09 � A A 4 \ UNDISTURBED EARTH OR COMPACTED NATIVE MATERIAL FULL DEPTH 1/20 EXPANSION UNLESS OTHERWISE SPECIFIED JOINT MATERIAL BY ENGINEER N 0 T E: SECTION 1. CONCRETE SHALL BE CLASS 3- 300OPSI 2. CONCRETE SHALL BE BROOM FINISHED 3. SIDEWALK THICKNESS SHALL BE 5-1/2", 4. SIDEWALK THICKNESS AT DRIVEWAYS SHALL BE 6' THICK, 5. CURB AND GUTTER SHALL BE POURED SEPARATELY FROM SIDEWALK 6, CONCRETE SHALL BE SPRAYED WITH CLEAR CURING COMPOUND OR SHALL BE COVERED AND KEPT MOIST FOR 72 HOURS, C. REVISIONS STANDARD DETAIL APPROVED BY DATE CONCRETE SIDEWALK DATE 7/24/01 SCALE NTS DWG NO. E2.13 TRACTION GRID PATTERN 1/4' NOMINAL DIMENSIONS N 0 T Ei I. RAMP TEXTURING IS TO BE DONE WITH AN EXPANDING METAL GRATE PLACED AND REMOVED FROM WET CONCRETE TO LEAVE A DIAMOND PATTERN AS SHOWN. THE LONG AXIS OF THE DIAMOND PATTERN S14ALL BE PERPENDICULAR TO THE CURB. GR13VES SHALL BE 1/8' DEEP AND 1/4' WIDE. 2. ALL CONCRETE SURFACES SHALL HAVE A PRO13M FINISH. CITY INSPECTION REQUIRED 17N FORM W17RK PRIOR TO p17UR, ACCESSIBLE RAMP SHALL BE POURED SEPARATELY FROM CURB AND GUTTER. 5.0, 5.01 -we (TYP) CONC CURB 1' WIDE TACTILE STRIP (TYP)- EHIND RAMP ALL LOCATMNS--.,\ SIDE RAMP 1110 (TYPICAL).-7 MAIN RAMP- 2% SLOPE 12'-18� 681 S 51-6r - VARIES RAMP SHALL BE FLUSH AT --owl 6# ka- THE GUTTER LINE 2% SL13PE 4 . a F-1 I P-4 I FZq I P-%4 -- --- -- 4TdlbTr.Il=Al CONCRETE CURB AND GUTTER SEE DETAIL E-2,8 95% COMPACTED .'ZIU215RADC, ADD CRUSHED (NEW CONSTRUCTION ONLY) RUCK BASE AS REQUIRED SECTION A 1/2' FULL DEPTH EXSPANSMN JOINT MATERIAL % 4- 0.: REVISIONS STANDARD DI ETA I L APPROVED BY DATE RAMP DETAIL FOR TYPE 5,5.1, AND 6.1 RAMPS DATE f9c SCALE NO. 7/24/01 NTS IDWG E2.25 4'(TYPICAL) 18' THER� OPLASTIC STOP BAR (TYPICAL AT CONTROL INTERSECTIONS ONLY) STRIPES S HALL START AND BE CENTERED ON THE ROAD CENTERLINE, STRIPES SHALL ALSO BE CENTERED ON LANE DELINIATORS OF MULTILANE ROADS, V CLEAR SPACE BETWEEN STRIPES (TYPICAL) 1' X 8' THERMOPLASTIC STRIPES (TYPICAL) F CLEAR SPACE BETWEEN STRIPE AND CURB (TYPICAL) NOTE, WHEN THERMOPLASTIC CROSSWALKS ARE PLACED ADJACENT TO OR ON STATE HIGHWAYS, THE LAYOUT PATTERN SHALL MATCH THE EXISTING STATE LAYOUT. CITY REPRESENTATIVE TO VERIFY LAYOUT. *#DIMENSION MAY VARY DEPENDING ON ROAD WIDTH (COORDINATE ACTUAL SPACING WITH CITY REPRESENTATIVE) CIT Y OF EDMONDS REV[ IONS APPROVED BY DA'T STANDARD DETAIL CROSSWALK DETAIL DATE SCALE DWG NO. 90- Igcj() 7/24/01 NTS E3.2 sl o 0:: 0 Z 0, �� z < 3 00ouiz u-m uj W 0 FY_ ;E tE �! 0 V)o w 'o z C3 uj uj En M= C) �-:D 0 V) cf) �_:z �� 0 z w- P2 wv, IXL Lli n L)<u C-3 o z 2 C. §i R 0 u, _,J OW02 w Z: = =:J> u- O:� L V) Wc'moo �; , , CWL >- a z = Z:z V) 0 0-- , _m< n 0 _j U);2�w Of 0 z. 0 0 L_ M 0 < a- W_ 0 mm w oo)crw- LLJ Z 3:: 1� oof <ubzo w Z ofmzw o 2� < 3: z z 02Fo>-w_ cn 0 F-_ o < V :): 'w, Z 1, 0 mwnoo c) V) Z;!� �n Kz< 0- ft� 0 < M<bi Z>-Onv) :Z cn 0 P" 0) Ln I C'4 00 E_ - Lcoll E- C4 11:31 Pr 1 03 0 z z CD z Z co < < z __j "I F--q ckf E­4 1.4 �D C) C14 Lu 0 5 a� 0 cf) C/) Z < V) > < < 00 < < U� �J) Q0 Illr) < Lo JOB NUMBER 01040 DESIGNED BY cs DRAWNBY EMC/JG CHECKED BY RDB/cs DATE 01/29/02 1115102 01040-CII 12:56pm 7/25/02, 08:32 AM01040-Cl2.plt - K I � LIMII U� [ItL L IMPORTED MATERIAL F PER - SPECIFICATIONS TYPE OF PIPE FOUNDATION LE� KPIPE BASE N 0 T E S : 1. PROVIDE UNIFORM SUPPORT UNDER BARREL 2, HAND TAMP UNDER HAUNCHES 3. COMPACT BEDDING MATERIAL TO 95% MAX DENSITY -owl IONS STANDARD DETAIL APPROVED BY DAlE PIPE BEDDING DAN SCAl Dwo NO. 7/24/01 NTS E4.1 TRENCH EDGES MUST BE SAW -CUT AND TACKED PRIOR TO FINAL TRENCH PATCH V) z 0 0 0 0 z TRENCH WIDTH ------------------ -------------- - - - - - - - - - - - - - --- - - - - - - - - - - - - - - - - -- MATCH EXISTING PAVEMENT DEPTH. ACP SHALL BE CLASS "B" AND COMPACTED IN MINIMUM 1-1/2" LIFTS WITH A MAXIMUM Fm OF 3" LIFTS - - . - .. - - - - - - - .. - . . - .% - . e. Z -6 REVISIONS STANDARD DETAIL APPROVED BY DATE TYPICAL TRENCH SECTION- CONTROL DENSITY FILL DATE 7/24/01 SCALE NTS m NO. E4.4 *90-1990 1 1 1 . TRENCH EDGES MUST BE SAW -CUT AND TACKED PRIOR TO FINAL TRENCH PATCH — 6" MIN DEPTH 5/8" CSTC LL_ 0 V) < z U) V) x o< 0:2 REFER TO SPECIFICATIONS FOR TYPES OF PIPE MAX TRENCH PATCH PAY WIDTH (SEE TABLE BELOW) ---------------- /_ -------------- * ------------------ ------------------ ------------------ X Lli 0 N LLI N 0 T E: REFER TO CITY OF EDMONDS MODIFICATION TO THE STANDARD SPECIFICATIONS FOR TYPE AND GRADATION. TABLE 1: MAX TRENCH PATCH PAY WIDTH TRENCH DEPTH PAY WIDTH V-41 40" 4'- 10' 60" 10'-20' 72" w 1D 0� w u co r u 3" MIN DEPTH CL 'B' AC TRENCH PATCH BACKFILL MATERIAL (SEE NOTE BELOW) , . , . % , . e. - F, Nil RF—VISIONS APPROVED BY DATE STANDARD DETAIL TYPICAL TRENCH SECTION I DATE 7/24/01- ISCA' NTS E4.2 x 01� u CL u 40" MAX. TRENCH PATCH PAY WIDTH TRENCH EDGES MUST BE SAW -CUT AND TACKED PRIOR TO FINAL TRENCH PATCH 40 45 # CIL 013' ASPHALT TRENCH PATCH /( 2fl MIN DEPTH - COLLECTOR STREETS ( 3' MIN DEPTH - MAIN ARTERIALS) u U CO SEE SPECFICATIONS FOR BACKFILL MATERIALS GRADATION SEE SPECIFICATIONS FOR DOMESTIC SERVICE AND A,R.V, CONNECTION DETAILS 1/4 PIPE O,D, MIN, 4' MIN PIPE BASE SHALL BE REQUIRED ONLY AS DIRECTED BY THE ENGINEER, SEE SPECIFICATIONS FOR PIPE BASE CLASS 52 DUCTICLE IRON PIPE MATERIAL GRADATION. UNLESS SPECIFIED OTHERWISE S. CITY** ...:--.-:E-D: lQ11ONS By DAM STANDARD DETAIL TYPICAL WATER LINE TRENCH SECTION WE 7/24/01 ISCALE NTS r" NO. E4.5 TRENCH EDGES MUST BE SAW -CUT AND TACKED PRIOR TO FINAL TRENCH PATCH 'I-, 6" MIN DEPTH 5/8" CSTC SEE PIPE BEDDING DETAIL o Fn < I- z m ui p 0 V) 0- V) ::�t x o< C) 0:2 PIPE ZONE z z 0 0� m V) MAX TRENCH PATCH PAY WIDTH 3" MIN DEPTH CIL 'B' (SEE TABLE BELOW) AC TRENCH PATCH ---------------- 1-4 --------------- ------------- ------------------ ----------------- ------------------ X BACKFILL MATERIAL (SEE NOTE BELOW) WRAP FOUNDATION ZONE ENTIRELY WITH FILTER FABRIC - 1- 1 /4" WASHED GRAVEL . TABLE 1: MAX TRENCH PATCH PAY WIDTH TRENCH DEPTH PAY WIDTH N 0 T E: 1 P-4p 40" REFER TO CITY OF EDMONDS MODIFICATION TO THE 4'- 10' 6021 STANDARD SPECIFICATIONS FOR TYPE AND GRADATION. 10'-20' 72)l 'ago-199V y % logo APPROVED BY DAM STANDARD DETAIL TYPICAL TRENCH SECTION -FOUNDATION STABILIZATION DAIE 7/24/01 SCAl NTS Im No' E4.3 ­ I APPROVED FOR CONSTRUCTION Ful� CITY ENGINEER DATE r, - T I BUILDINU Dl'-'P'I. z Lo L0 C4 00 Lo cl-A E, 04 og 0 Z z 0 U z z z ic� �D C4 C) C4 Z 0 Lu 5 :E� F- M 0 cn F- hl F- JOB NUMBER 01040 DESIGNED BY cs DRAWN BY EMC/JG CHECKED BY RDB/CS DATE . ';d 01/29 02 SHEET NUMBER C12 7 71r; 7771"A"7 1-17""71,1.m, 4" OR 6" CONC RISERS �4 " MIN.— MAX HGT— 18") ROUT AND PROVIDE SMOOTH FINISH INSIDE AND OUT POLYPROPYLENE SAFETY STEP 12- O.C. (TYP) ��� SAND COLLAR FRAME AND COVER N 0 T E: 1. LOCATE MH LID OUTSIDE THE WHEEL PATH OF THE TRAVEL LANE. 2. BASE REINFORCING SHALL BE #4 REBAR AT 12" O.C. BOTH WAYS. 3. LARGER MH TO BE REVIEWED ON A CASE BY BY CASE BASIS USING APWA STANDARDS. 4. JOINTS SHALL BE RUBBER GASKETED ONLY. MH PER W.S.D.O.T. APWA STANDARD PLAN B-23o. 25" LOCKING LID WITH THE WORD "SEWER" ON IT REBAR MIN 2" CLEARANCE/ ECCENTRIC PRECAST CONE , PRECAST SECTIONS 4" MIN. THICKNESS I 6- MIN) ,-CUT OUT FOR EXISTING SS SET BARREL OVER EXISTING SS PIPE CONSTRUCT CHANNEL SHELF SS MANHOLE CUT' IN 4" OR 6" CONIC RISERS �4 MIN.- MAX HGT- 18") ROUT AND PROVIDE SMOOTH FINISH INSIDE AND OUT POLYPROPYLENE SAFETY STEP 12- O.C. (TYP) V=R� SAND COLLAR FRAME AND COVER N 0 T E: 1. LOCATE MH LID OUTSIDE THE WHEEL PATH OF THE TRAVEL LANE. 2. BASE REINFORCING SHALL BE #4 REBAR AT 12- O.C. BOTH WAYS. 3. LARGER MH TO BE REVIEWED ON A CASE BY BY CASE BASIS USING APWA STANDARDS. 4. JOINTS SHALL BE RUBBER GASKETED ONLY. MH PER W.S.D.O.T. APWA 25" LOCKING LID WITH THE MORID "SEWER" ON IT ECCENTRIC PRECAST CONE .PRECAST SECTIONS 4" MIN. THICKNESS CONSTRUCT CHANNEL SHELF I STANDARD PLAN B-23o. 017MAP KAIM 17" rl IrA &W-Fll 1090-19vu m U.j .,Q.F ...... "'K STANDARD ETAI I "IF, I �Jil -,�'l I fill I ui z RESIDENCE 0 z cr — CLEAN13UT WITH 45m (L BEND AND CAP w ui V) NOT TO EXCEED 100' BETWEEN X CLEAN OUTS I CLEANOUT (WYE WITH C AND LOCKING LAMPHOLE VER) w CL LLJ 0 W Z a -I -i W " 7A W WATER TIGHT CAP ATER Tj GHT S LL-RISER 12 PVC, -- SLEEVE 6" RISER/ S W 4' OR 6' SIDE SE ER 61 WYE AND 45)x GENERAL CLEANOUT DETAIL AND 1/8 BEND 4 4� lz 0 All (FOR FUTURE DEVELOPMENT) PLACE 2X4 AT END OF SIDE SEWER STUB AND CUT TO LENGTH TO INSURE 3 FEET EXTENDS ABOVE GRADE. PAINT TOP 18 INCHES WHITE. IN 3 INCH HIGH LETTERS STENCIL THE NUMBER OF EVEN FEET FROM GROUND ELEVATION TO THE SEWER STUB INVERT. 8 GAUGE WIRE TO BE DOUBLE WRAPPED AROUND PIPE AND 2X4 STAKE AT OR ABOVE FINISHED GRADE. LOCKING LAMPHOLE COVER TO BE PLACED AT FINISHED GRADE (SEE STD SEWER CLEANOUT DETAIL) A VAT& 14 1 f nt iLLqv-Ll 51 1`-, rr"ri —11F lluffi I i nlipLl W z 6" WYE AND 45* BEND to 6" LATERAL SEWER LINE — 6" TEE OPE- 2% MIN. TO v 50% MAX POSSIBLE SEWER MAIN LOCATION RUBBER JOINT BISCUIT PLUG OR OTHER APPROVED WATERTIGHT PLUG N 0 T E: POSSIBLE 1. WHEN TAPPING INTO EXISTING MAIN SEWER MAIN AN INSERTA-TEE SHALL BE USED. 22.5* OR LOCATION PLACEMENT OF TEE SHALL DEPEND 45* BEND ON DEPTH OF SEWER MAIN. AS A MINIMUM, THE TEE SHALL BE PLACED AT A 45 DEGREE ANGLE. 2. IF CONNECTING SIDE SEWER TO EXIST CONCRETE LATERAL, A CONCRETE/PVC, ADAPTER SHALL BE USED AND SECURED PER MFGR'S INSTRUCTIONS. 0- :-F -- STANDARD DETAIL TYPiCA,L SIDE SEWER DATE WAM NTS 00. 1 7/24/01 1 r" ING LAMPHOLE COVER CONCRETE LOCKING COVER 2'x2x4" THICK 6" CITY STUB 4' OR 6' SIDE SEWER 1 CLEAN OUT DETAIL AT EASEMENT LINE CONCRETE LOCKING LOCKING LAMPHOLE COVER (OLYMPIC FOUNDRY CO) COVER 2'x2x4" THICK 12' MODEL 5931 OR EQUAL ASPHALT SURFACE a NOTE. SIDE SEWER JOINTS SHALL BE GASKETED 6' RISE ,12" PVC SLEEVE PVC CAP TYPICAL CLEANOUT UNDER ASPHALT OR CONCRETE - lt4 A REP P" 0"' ROVED L7lltrvllPlC VIEWWATEA D1 ny: ------------- Date: .-ahuj BUILDINU D. Bo Of WA�S,�q,' "'Ol CT 0 APPROVED FOR CONSTRUCTION �� 6t--� 09/ A-3jk CITY ENGINEER DA TE 1018 X' GISTV- ONAL EXPIRES OCTOBER 24, 2002 Ld W w . V) C) a X: re LLJ D Z F- LAJ Z Lj m< 6 000tAiz t� W F= M Ld rL V) Lq M F- LLJ 5 1, > V) w Z 0 LLJ w V) W z m z Ld 0-1 0 0 mZwKvo) q Lu CXL wn :0:1 V) z o LJLJ :2 'm IML 0 :2 ;E =L) W 0 w z w E3 0 V) V) o Of w o �- z Z,,VL zz it: <<,,=i 0 1<1 XO F-: =M V46qo�- 0 Ld 0 L, 0 LL. 0 z LL" ": 0 cLwZ < w �c - F- 0 - 0 <unzo wz Ld 0 Z< 3: y F- L925 V) M r= C) w p- N ::,n z ILJ W=)o o F- V) < < I-)- z V) Z-m<F- 0 < W < Lo Z>-oov) Rm <ML,<=) U-) z C" 0 0) F--q 0 co 00 E- CN V) E- CD (4 C Z 0 z z cs z �D C14 Z LLJ F- 0 3:F V) 0 z F- V) kzl:.4 F- s CD Ld LLJ a. IVA" Ld > D 00 < :�E n LLJ �7 (-) < n < Z ry �- 0 ry u� :�i n LLJ (,o(-o n n �7 0 0 Ld JOB NUMBER 01040 DESIGNED BY cs DRAWN BY EMC/JG CHECKED BY RDB/CS DATE 01/29/02 C13 02112102 01040-03 4:25PU HORIZONTAL BLOCKING mwmwu FIXI I 1ro - 22r - 3(r VMWA WO 4 TURN8UCKLES------_____2_.m�/VB THREAD 6" ........... S PAINT SHACKLE RODS WITH 2 COATS OF COAL TAR OR ASPHALT PAINT TYPIEVIROOM FOR4VVR1M8M 4 TURN BUCKLES THREAD 6" Pipe BEARING AREA OF BLOCK SQ.FL Size DIA. TEES & 90* 45* 22-1/2* IN. ENDS ENDS ENDS ENDS 4" 3 1 1 1 6. 4 4 2 1 81, 7 6 4 2 10" 11 10 6 3 12" 16 14 9 5 NOTES ALL BLOCKING SHALL BE POURED AGAINST FIRM UNDISTURBED SOIL BEARING AREA AT FITTINGS NOT GIVEN IN BEARING TABLE SHALL BE AS DIRECTED BY THE ENGINEER. MEN POURING AGAINST PLUGS AND BLIND FLANGES SET STEEL METER BOX LID AGAINST FITTING TO KEEP CONCRETE OFF BOLTS LAYOUT TO BE APPROVED BY DISTRICT PRIOR TO CONCRETE POUR. THRUST BLOCKING D- ................ .. . . .............. ................. ................. ....................... S PAINT SHACKLE RODS WITH 2 COATS OF COAL TAR OR ASPHALT PAINT /9 REFER TO CHART 2-1/2- SIAMESE HOSE CONNECTION­-4- I (AS REQ'D BY FIRE DEPT) L L - - - - - - - - - - - - - - - - - PRE -ASSEMBLED, DOH STATE APPROVED I ICHECK VALVE 6" DOUBLE DETECTOR CHECK VALVE ASSEMBLY (TYP) 18" 1 MIN. MIN. -FLOK FIL X FL TEE A FLANGED COUPLING Z ADAPTERS REQUIRED ON D BOTH ENDS OF DDCVA m umi /-SENSUS SRII W/TRPL -J.'c Z _J _J7 0 REMOTE READ. THE TRPL SHALL BE Z INSTALLED ON HATCH CLOSE TO HINGE Lu Z 0 In V, Ld =� m �_ �j mo IRI F I EAF LID (MODEL-L.W. HATCH- TYPE DX) LADDER PER APWA STD PLAN #41 GwZ . m -. w W o ALIGN WITH HATCH. -jo < m VAULT SIZES GENERAL NOTES:. 1. SPRINKLER CONTRACTORS LIKE TO ADD 4" OUTLET TEE DOWN STREAM FOR FIRE DEPT. CONNECTION. 2. ACCESSES BY L..W. HATCH: TYPE "D" H-10 PEDESTRIAN LOAD; HD-10 TRAFFIC LOAD) 3. VAULT COVER GUTTER DRAIN SHALL CONNECT TO A DRY WELL OR CATCH BASIN. 4. DDCVA MUST BE TESTED BY A QUALIFIED TESTER WITH PUBLIC WORKS PRESENT DURING TESTING. METER SIZE AND TYPE APPROXIMATE EQUIP DIMENSIONS MINIMUM INSIDE VAULT DIMENSIONS (EXCLUDES SIAMESE CONNECTION) A B c D LENGTH WIDTH HEIGHT 4" X 3/4" 2'- 9 1 1 1 0'-6" 4'-3" 101 _O$1 5-01' 7'-0" 6" X 3 4" 3'-9" 1'-2" 0'-8" 5'- 6 _011 6'-0" 7_0" 8" X 3/4" 4'- 5 11 11-4" 0'-9" 6'-4'0 120-0" 61-0" 7'-0" 10" X i tj 61-01' 11-8'f Ot-ll*' 8'-6" 141-6" 71-0" 70-010 ------ 7- cy,90- 1 9qu Tff w Room FOR: I I r* - 2210 - 300 MOM BENDS 300 S D L 4 300 lIr 221 8 11 2.0 22 P Zo 30 17 2.6 6 300 lIr 221 11 25 2.2 2.9 P Zo 30 41 3.5 8 300 llr 23 16 47 2.5 3.6 P 2.0 30 .70 4.1 8 2.5 10-12 250 lIr 221 32 88 3.2 4.5 P f 2.0 3.0 30 132 5.1 16 225 lIr 221 70 184 4.1 5.7 f lw 3.0 4.0 30 275 6.5 Ir llir 221 91 225 4.5 6.1 f Ir 3.0 4.0 30 330 &9 ly 4.5 24 200 llr 128 320 5.0 6.8 1 ly 3. 4.5 30 480 7.9 1p 53 TIff v BLOOM FOR 4V VERIM BENDS 4 6 300 45 30 6S 3.1 4.1 P 2.0 8 12 16 250 225 123 232 478 5.0 6.1 7.8 S lw 2.5 4.0 20 24 200 5w 82D 82 9A Ir ly 4.5 M* 0. N.'*D S. REVISIONS APPROVED BY DATE STANDARD DETAIL COMMERICAL DOUBLE DETECTOR CHECK A08ABLY (PLM DATE SCALE DWG NO. 7/24/01 NTS E7.8 Q (c 0 Lo Lc TRPL REMOTE READ FINISHED GRADE t m I., 07 :-- i.'2- ;u DRAIN PIPE m (DRAIN TO DRY WELL < OR CB) Z m 1E .0 11.2 Z m C3 u >Fq Z 1 ;01 0 w 0 0 Fin 0 .0 > P la 6" -5/8" MINUS CSTC COMPACTED ig TO 95% DENSITY FOGTITENO.2METERBOX W/ OM LID 6 INSPECIION PLATE OR 17x3O MASTIC BOX W/ WADING COVM (SrEI1 LID REVRED IN PAMENq 2" DOUBLE STRAP SADDLE AND 2" CORP STOP AT M 2" TYPE "K" COPPER 3" HDPE SDRI I 3x2* HDPE REDUCER UCER ... �7 HDPE TRANSIT= FITTING TO BRASS 2' IP THREAD DETAIL A/C 14 BOTH SIDES OF METER RESILIENISEATTAPPING rA7E VALVE (RjMJ) vxvxrm BURYIN SAND 11*i;.'.V*.'.'.'. X 1-112" 2" METERS NO SCALE ELEVATION WET -TAP CONNECTION 72" DOUBLE LEAF TRAFFIC BEARING LID[r� WITH DRAIN SLOTS L.W. HATCH -TYPE D, METER BY DISTRICT 20 METER SETTER WIN l'BT-PASS FORD MODEL VFH77-l5Bx170REW CENTER mErm IN W& VERTICALLYAND HOWATALLY. UNION BOTH SIDES SEE DETAIL A/C14 FOR 3" SUPPLY AND BRANCH LINES lOMILPLASTIC TAPPING TEE ROMM MODEI. FES 420 W1 RISION SM COATED 7HRIJIST BI=NG PER SGMXM IOMILMASTICBETMTEE ANDW=NG. E: SIAM ESE CONNECTION (AS REQ'D BY FIRE DEPT.) LADDE - A.P.W.A. STD (PLAN #41) EXTEN OUT AS REQUIRED TO ALIG WITH HATCH A UBLE CHECK VALVES- U L. APPROVED O.S.Y. P) u 2 MINIMUti GRINNEL PIPE SADDLE AND STAND#258 OR EQUAL] OLYMPIC FDRY 10" FLR. DRAIN #52 OR EQUAL CLO N MEDALLION, N & If RELIANT, WAMM B-6 5 lie myo, BREAKAN viromADAPFER,2a FAMESTER01MEL-CAT' h3W COMM PAD 10 Ma, MASTIC BEMEEI ffam'BLOOMAND OVM WAM I= 1/4 C.Y. 1-1/2' WASHED ROCK 10 MIL PLASTIC CONCRETE BLOCI POUR IN PLACE. MAINTAIN CLEAR FOR DRAIN POW 4" x 4" x 8" BF UNDISTURBED EA 3/4" DIA. SHACI_ W/ 2 COATS TAR OR ASPHALT PAINT, OR MEGALUGS. NOTES: VALVE BOX. CAST IRON SLIDE EXTENSION ALIGN VALVE BOX EARS ALONG VALVE AXIS BLUE,DOUBLE-SIDED RAYOLITE MARKER PLACE OFF CENTER OF ROAD TOWARDS HYD. 6" AWWA C509 RESILIENT SEAT GATE VALVE NON RISING STEM, -0" RING SEALS, FL x MJ 6" FLANGED TEE CONCRETE BLOCKING PER SCHEDULE 10 MIL PLASTIC BET. BLOCK TEE x 8" BRICK 'IPE, CLASS 52, CEMENT LINED, 3'-0" MIN. LENGTH REQUIRED FIRE HYDRANT ASSEMBLY DETAIL MARK MDBamqm A 91 CAP, TAP 21, IPS B C r NMI BRASS, 61, LONG D r HIPPLE, BI1IASSq r LONG E 2 '"Swom'sm'SWINGAM F 2 Z' rALV., STEEL. Im MmAm' Lem To Sw G 1 BOX4)ff`IER STMM H I !'�V* RM, GALV., DARL I fir WLE MiREADED) i I ��GATEVALVE-OMSTANDARD K I r 450 EIM, QLV. (MMADED) L 114CY WASRED ROCK M I CONCRETE TIIW 13100� CAST IN PLACE Bmm&vNsrcrorty IOMILMASTICAGAINSTCW N METER BOX-FOGTITE #10 0 2' W x 2 1 /21 NP NAT. ADAPWRE HOSE), w/CAp P V x 40 x W BRICK ON tIMMUM WL NEW SECTIONS OF WATER MAIN THAT ARE INSTALLED WHEN EXPANDING A DISTRIBUTION SYSTEM MUST BE SEPARATED FROM THE EXISTING SYSTEM. UNTIL SATISFACTORY FLUSHING, DISINFEC11ON AND BACTERIOLOGICAL SAMPLING HAS BEEN COMPLETED, THE NEW WATER MAIN MUST BE CONSIDERED CONTAMINATED. IN ADDITION, THE CHLORINE CONCENTRATION USED FOR DISINFECTION PROCEDURES (MINIMUM 25 mg/1) MAKES WATER NON -POTABLE. YI AN APPROVED BACKFLOW PREVENTION ASSEMBLY MUST BE USED ON THE SUPPL NG WATER LINE WHEN FILLING THE NEW WATER MAIN DURING DISINFECTION AND FLUSHING. THE BACKFLOW PREVENTION ASSEMBLY AND SUPPLY PIPING MUST BE REMOVED DURING HYDROSTATIC PRESSURE TESTING OF THE NEW WATER MAIN. AFTER SATISFACTORY BACTERIOLOGICAL SAMPLE RE8ULTS ARE OBTAINED FROM THE NEW WATER MAIN, SECTIONS OF CONNECTING PIPE MUST BE INSTALLED BETWEEN IT AND THE EXISTING SYSTEM. BEFORE INSTALLATION, THE INTERIORS OF ALL PIPE AND FITTINGS USED TO MAKE THE CONNECTION MUST BE SWA88ED OR SPRAYED WITH A IX AVAILABLE CHLORINE SOLUTION. Nc Q� APPROVED BACKFLOW PREVENTION ASSEMBLY, FEBCO MODEL m 825Y, 2" OR APPROVED EQUAL a - HYDRANT NEW ON EXISTING n-HYDRANT m WATER MAIN c� FLUSHING DISCHARGE ALTERNATIVES uj uj Uzi NEW HYDRANT MAY BE 21reMMYHOSE USED FOR FLUSHING DI LENGTH AS REQUIRED SCHARGE IF TEE IS----*- WTHIN iV OF THE END 2" I.P. TEMPORARY CAP OF PIPE OR PLUG WASHED DRAIN ROCK 1. ACCESSES BY L..W. HATCH: TYPE "D" H-10 PEDESTRIAN LOAD; HD-10 TRAFFIC LOAD) 2. VAULT COVER GUTTER DRAIN SHALL CONNEC1 TO A DRY WELL OR CATCH BASIN. TEMPORARY NEW HYDRANT TEE TEMPORARY CAP TEST BLOCKING WATER MAIN OR PLUG WATER MAIN FILLING DETAIL Pww D - B 0 WAs 'v TEMPORARY TEST BLOCKING 21018 I TE �/o 4i EXPIRES OCTOBER 24, Z 0 Ln m (D U) Lo I CD Q co Q-D E- CO U-) 04 7t� C) 00 0 Z Z 0 C.D Z - 2E Z �D cj C:) Z 0 F- F-14 1� U) F- w Ld cli Lo 1,2112102 011040-C14 4:30RU, 7/25/02, 08:29 AMO 1 040-C 15. pit 7/25/02, 08:28 AM01040-C16.plt N-S DRIVEWAY PROFILE SCALE: H 1*=20' SCALE: V 1"--5' ND T _T_ J .7 '.1-1 J J.-I _.L! J .. .... J_ J.. J, I., J. I 1.1 - . . ......... J.- T j -T. I : J., 1.44-11--t �.T - - - - - - - - - - - Lt. _'T 11 J­.� J J.4_ 7-1,7 I L 41- 1 1 i J J.- I.J_1 1-J, J_j _44 T L EN Ro N. 7 _185 _r� -J. . 4. --H N-S DRIVEWAY PROFILE SCALE: H 1"­20' SCALE. V 1"-5' A F IV look I __ r J-4- 4" F . . . . . . . . . . -IS! ID 7F I F-T, - ,� j Lf 14 _3_1 11 1 1_4 T J.- I -A , Thi , I-- [- I If — T_ t Id-, J, ST TO EAST DRIVEWAY PROFILE SCALE: H 1"--20' SCALE- V 1'­5' BUILDING DEPT. I). Bo of WAS&I A�11 i- 21018 APPROVED FOR CONSTRUCTION GISTE SION L OCTOBER 'CITY ENGINEER DATE Z 0 Lo 0') 00 E- c, co 0 Z z z 0 F__ (.D z V) < z E-4 _j :�cl_ ck: �4 �D Z LAJ L) V) 0 V) LLj LLJ R� U) Lr) 1115102 01040-CI6 1:44pm 10 SIT I I L � PLANT SCHEDULE SYMBOL BOTANICAL/COMMON NAME TREES 0 ACER PLATANOIDES 'PARKWAY'/ PARKWAY NORWAY MAPLE ACER CIRCINATUM/ VINE MAPLE CALOCEDRUS DECURRENS/ INCENSE CEDAR BETULA JACQUEMONTI/ JACQUEMONT BIRCH + PSEUDOTSUGA MENZIESII/ DOUGLAS FIR PINUS NIGRA/ AUSTRIAN PINE 0 PYRUS CALLERYANA 'CHANTICLEER/ 'CHANTICLEER' FLOWERING PEAR SHRUBS. ARBUTUS UNEDO 'COMPACTA7 8 COMPACT STRAWBERRY TREE AUCUBA JAPONICA JAPANESE AUCdBA BERBERIS VERRUCULOSA/ WARTY BARBERRY CISTUS PURPUREUS PURPLE ROCKUSE 00PD EUONYMUS ALATA 'COMPACTA'/ DWARF WINGED EUONYMUS ILEX CRENATA VAR. "CONVEXA'/ CONVEXLEAF JAPANESE HOLLY LIGUSTRUM JAPONICUM 'TEXANUM'/ @ TEXAN JAPANESE PRIVET 5LIX-s. A zi 097 �nj I "n ==I u=m G"rw9a A&~ &.Am" pArw—*% I I T-.f 5LDG. 5 SIZE/COMMENTS SYMBOL BOTANICAL/COMMON NAME SHRUBS (CONTINUED) 2" CAL., MATCHED SET. B&B 4) MYRICA CALIFORNIr"A / Pa-E SPECIMEN QUALITY CALIFORNIA 8-10' HT., MUL*nSTEM, SPECIMEN QUALITY (o PHOTINIA FRASERI/ FRASIER'S PHOTINIA 6-7' HT., B&B @ PIERIS JAPONICA 'FLAME -OF -THE -FOREST'/ 'FLAME -OF -THE -FOREST' PIERIS 2" CAL., MATCHED SET, B&B (8) PINUS MUGO MUGHUS/MUGO PINE SPECIMEN QUALITY P0TEN-nLLA FRUTICOSA/ 6-7' HT., SPECIMEN QUALITY, B&B BUSH CINQUEFOIL PRUNUS LAUROCERASUS 'ZABELIANA�/ 6-7' HT., B&B, FULL & BUSY ZABEL'S LAUREL RHODODENDRON 'NOVA ZEMBLA'/ 'NOVA 2" CAL., MATCHED SET, B&B ZEMBLA' RHODODENDRON 'NANA'/ 0 SKIMMIA JAPONICA DWARF SKIMMIA @ VIBURNUM TOMENTOSUM MARIESII/ 5 GAL. CONT., 24" MIN. HEIGHT, MARIE'S DOUBI EFILE VIBURNUM SPECIMEN QUALITY VIBURNUM DAVIDII/DAVID'S VIBURNUM 5 GAL. CONT., 24" MIN. HEIGHT, GROUNDCOVER- SPECIMEN QUALITY CEONOTHUS GLORIOSUS/ 5 GAL. CONT., 18- MIN. HEIGHT, PT. REYES CEONOTHUS FULL & BUSHY 5 GAL. CONT., 18" MIN. HEIGHT, COTONEASTER 'COW BEAUTY/ 'CORAL FULL & BUSHY BEAUTY COTONEASTER 18-24" HT., B&B, VIP- GAULTHERIA SHALLON/SALAL FULL & BUSHY 18-24- HT., B&B, FULL & BUSHY LAWN AREA 5 GAL. CONT., 24" MIN. HEIGHT, FULL & BUSHY BIOSWALE SEED MIX OWN - Sim ME m m - I - I I wzzwzzoollo SIZE/COMMENTS 5 GAL. CONT., 18- MIN. HEIGHT, SPECIMEN QUALITY 24" MIN. HT., B&B, FULL & BUSHY, SPECIMEN QUALITY 15-18- HT., B&B, FULL & BUSHY 15-18" SPREAD, B&B, FUH & BUSHY 2 GAL., CONT., FULL & BUSHY 18-24" SPRD., B&B, FULL & BUSHY 21-24" SPREAD, B&B, SPECIMEN QUALITY 2 GAL. CONT., 15" MIN. SPRD., PLANT1 MALE PER 3 FEMALE PLANTS 24-30- HL, B&B 15-18- SPREAD, B&B, SPECIMEN QUALITY 1 GAL. CONT., PLANT @ 24" O.C. 2 GAL. CONT., PLANT 0 30- O.C. 1 GAL. CONT., PLANT 0 24- O.C. FESCUE/RYE BLENDS SEE SPECS FOR SEED MIX & APPLICATION RATES Be APPROVLCD BY PLANNING Sl LAND5GAFE PLAN PLANTING NOTES 1. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL OTHER SITE IMPROVEMENTS PRIOR TO STARTING LANDSCAPE WORK. 2. CONTRACTOR SHALL USE CAUTION WHILE EXCAVATING TO AVOID DISTRUBING ANY EXISTING UTILITIES. IF ANY ARE ENCOUNTERED, CONTRACTOR IS TO PROMPTLY ADVISE GENERAL CONTRACTOR AND�OWNER. 3. CONTRACTOR SHALL MAINTAIN AND WATER PLANT MATERIAL UNTIL OWNER'S FINAL ACCEPTANCE. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING -THE QUANTITY OF PLANT MATERIAL REPRESENTED BY SYMBOLS ON THE DRAWING AND/OR COMPUTING SPECIFIC QUANTITIES OF PLANT5-UTILIZING EQUILATERAL TRIANGULAR SPACING PATTERN AT THE ON —CENTER DISTANCES SHOWN. WHERE GROUNDCOVER ABUTS CURBING, SIGNS, WALKWAYS, OR POLES, MINIMUM PLANTING DISTANCE SHALL BE 12" FROM CENTER OF PLANT TO CURBING, WALKS, ETC. MINIMUM PLANTING DISTANCES SHALL BE 14 FROM CENTER OF ALL TREES. 5. SUBGRADE TO WITHIN 1/10TH FOOT PROVIDED BY GENERAL CONTRACTOR UNL SS OTHERWISE NOTED. 6. MIN. 4" DEPTH 5—WAY TOPSOIL (SEE SPECIFICATIONS) IN ALL LANDSCAPE AREAS, INC UDES BED AREAS, SOD LAWN & HYDROSEEDED AREAS. 7. MIN. 2" DEPTH BARK MULCH IN ALL PLANTING BEDS. 8. ALL PLANT MATERIAL AND GRASS AREAS SHALL BE FERTILIZED (SEE SPECIFICATIONS FOR TYPE AND APPLICATION RATE). 9. ALL PLANT MATERIALS SHALL CONFORM TO AAN STANDARD FOR NURSERY STOCK, LATEST EDITION: A. GENERAL: ALL PLANT MATERIALS FURNISHED SHALL BE HEALTHY REPRESENTATIVES, TYPICAL OF THEIR SPECIES OR VARIETY AND SHALL HAVE A NORMAL HABIT OF GROWTH. THEY SHALL BE FULL, WELL —BRANCHED, WELL—PROPORTIDNED, AND HAVE A VIGOROUS, WELL —DEVELOPED ROOT SYSTEM. ALL PLANTS SHALL BE HARDY UNDER CLIMATIC CONDITIONS SIMILAR TO THOSE IN 'THE LOCALITY OF THE PROJECT. B. TREES, SHRUBS, GROUNDCOVER: QUANTITIES, SPECIES AND VARIETIES, SIZES AND CONDITION AS SHOWN ON PLANTING PLAN AND PLANT LIST. PLANTS TO BE HEALTHY, VIGOROUS, WELL —FOLIATED WHEN IN LEAF FREE OF DISEASE, INJURY, INSECTS, DECAY, HARMFUL DEFECTS, ALL WEEDS AND WEED ROOTS. NO SUBSTITUTIONS SHALL BE MADE WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT. 10. PLANT SHRUBS AND TREES A MINIMUM OF 36$$ FROM CURBS TO ALLOW FOR CAR OVERHANG, UNLESS WHEELSTOPS ARE PROVIDED. 11. CONTRACTOR TO PROVIDE A DESIGN —BUILD AUTOMATIC IRRIGATION SYSTEM (OR INSTALL THE DESIGNED AUTOMATIC IRRIGATION SYSTEM, IF PROVIDED) FOR ALL PLANTING AREAS. POP—UP SPRAY SPRINKLERS TO BE USED WHEN LOCATED ADJACENT TO WALKWAYS. 12. ASPHALT OVERHANG IN PLANTING BEDS SHALL BE 6" OR LESS. GENERAL CONTRACTOR RESPONSIBLE FOR CUTTING AND REMOVING ANY EXCESS ASPHALT. 13. PROVIDE 8 19 MOW STRIP WHERE SOD IS ADJACENT TO BUILDING; BOARDED WITH WOOD HEADER. 14. PROVIDE 4X6" PRESSURE —TREATED HEADER BETWEEN PLANTING BED AREAS AND El L.MVV I u uz)r_r_ur_ AKLA 7­ r7Z "IE �11 I/ — DEC - 5 20iull BUI! DING DEZ-F7, STREET FILE 7r8l) 3 z tu Z z < T_ _j e OL tu < OL z z lu tu 21 1 SHEET: L I OF: SHEETS PERMIT 1 — 1 /4"1 P. 0. C. 1 /2" 84TH AVENUE WEST IRRIGATION NOTES IRRIGATION NOTES (WORK BY OTHERS: GENERAL CONTRACTOR OR OTHER SUBCONTRACTORS) 1. GRADING: 8. PROVIDE COMPLETE BACKFLOW PREVENTION TO MEET LOCAL REQUIREMENTS, CHECK a. CONTRACTOR IS TO PROVIDE A SUBGRADE OF + .10' FINISH GRADE LESS WITH WATER DISTRICT, AND INSTALL PER CITY REQUIREMENTS AND PLAN SET TOPSOIL DEPTH. DETAILS. NOTIFY LANDSCAPE ARCHTECT/DESIGNER OF ANY DESCREPANCY OF b. REMOVAL OF ALL ASPHALT EXTENDING GREATER THAN 4" BEYOND BACK THIS INSTALLATION. OF EXTRUDED CURBING, TO ALLOW FOR IRRIGATION HEAD PLACEMENT. 9. ADJUST PRESSURE REGULATOR TO ACHIEVE BEST PERFORMANCE, APPROXIMATELY 2. WATER SOURCE: 70 PSI. a. CONTRACTOR TO SUPPLY AND INSTALL WATER SOURCE AND EXEMPT METER 10. PROVIDE AND MOUNT IRRIGATION CONTROLLER AS NOTED ON PLANS. AS PER CITY OF MOUNTLAKE TERRACE STANDARDS. PROVIDE GALVANIZED 11. PROVIDE AND PULL WIRES FROM OUTSIDE VALVES THROUGH CONDUIT PROVIDED BY STANDARD THREADED STUB —OUT WITH THREADED CAP ON DISCHARGE SIDE OF METER. ELECTRICAL CONTRACTOR TO CONTROLLER LOCATION. STUB —OUT TO BE INSTALLED APPROXIMATELY 18 INCHES BELOW FINISH GRADE. 12. CONNECT LOW VOLTAGE CONTROL WIRES TO CONTROLLER. 3. ELECTRICAL: 13. ALL WORK PER LOCAL CODE, INSTALL ALL MATERIALS PER MANUFACTURER'S a. CONTRACTOR TO SUPPLY 110 VOLT POWER TO CONTROLLER LOCATED SPECIFICATIONS. ON DRAWING AND PROVIDE THRU—WALL CONDUIT FOR WIRING. 14. ALL OUTDOOR VALVES TO BE PLACED IN "AMETEK" BOXES WITH SNAP LIDS. SET IRRIGATION NOTES (WORK BY IRRIGATION CONTRACTOR) BOX HIGHER THAN FINISH GRADE SO TOP OF BOX IS FLUSH WITH SOD OR MULCH. 15. MAINLINE PIPE TO BE BURIED 24", LATERALS 18" BELOW FINISH GRADE. NO 1. NO IRRIGATION WORK IS TO START WITHOUT AN APPROVED SUB —GRADE FINISHED ROCKS OR DEBRIS TO BE BACKFILLED OVER PIPE. BY THE GENERAL CONTRACTOR OR OTHER SUBCONTRACTORS. 16. PLACE ALL LAWN POP—UP SPRINKLERS 2" FROM ALL CURBS AND SIDEWALKS. 2. IT IS INTENDED THAT THE CONTRACTOR SHALL INSTALL SYSTEMS THAT ARE INSTALL SPRINKLERS ON TRIPLE SWING JOINTS. INSTALL HEADS ADJACENT TO COMPLETE AND FUNCTIONING PROPERLY IN EVERY WAY, AND PROVIDE A ONE YEAR BUILDING NO CLOSER THAN 3" TO ANY WALL, WATCH FTG. DRAIN LINES. GUARANTEE AGAINST WORKMANSHIP AND MATERIAL FAILURE. 17. PLAN IS DIAGRAMMATIC. ADJUST LINE LOCATIONS AS NECESSARY. HEADS TO 3. CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO PLANT MATERIAL DUE TO BE PLACED ACCORDING TO PLAN. ALL IRRIGATION EQUIPMENT IS TO BE PLACED IRRIGATION SYSTEM FAILURE DURING INSTALLATION OF PLANTS. WITHIN PLANTING AREAS. 4. CONTRACTOR SHALL CHECK AND VERIFY ALL SITE CONDITIONS, UTILITIES, AND 18. CONTRACTOR IS TO INSTALL "IN —LINE DRAINS" AS REQUIRED TO STOP LOW HEAD SERVICES PRIOR TO TRENCHING. CALL LOCATION SERVICES @ (1 —800-424-5555) RUN—OFF AND EROSION. PROVIDE A ONE CUBIC, FILTER FABRIC COVERED, 5. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THEIR WORK WITH ALL GRAVEL SUMP AT EACH DRAIN. MINIMUM 2 DRAINS PER VALVED ZONE. OTHER TRADES AS NEEDED. 19. PROVIDE OWNER WITH "AS BUILT" DRAWINGS AND OPERATOR'S MANUAL UPON COMPLETION. INSTRUCT OWNER AS TO PROPER WINTERIZATION OF IRRIGATION 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL IRRIGATION SLEEVES UNDER SYSTEM (BLOW OUT). PAVING, SLEEVE PIPE TO BE SCHEDULE 40, PVC, MINIMUM DEPTH 24 BELOW FINISH SURFACE, TAPE PIPE ENDS AND STAKE LOCATION OF PIPE ENDS, 20. ENTIRE SYSTEM MUST BE OPERATED ELECTRICALLY AND RUN THRU ONE COORDINATE WITH GENERAL CONTRACTOR PRIOR TO INSTALLATION. CONTINUOUS OPERATIONAL CYCLE IN THE PRESENCE OF THE DESIGN ER/ARCH ITECT OR OWNER AND PROVIDE COMPLETE AND ACCEPTABLE COVERAGE, ACCEPTANCE IN 7. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF IRRIGATION CHASES WRITING WILL START WARRANTY PERIOD THAT WILL INCLUDE ONE ACTIVATION UNDER PAVING ON STRUCTURE, THROUGH WALLS, SLABS, CURBS, ETC. AS NEEDED AND ONE DEACTIVATION OF SYSTEM. FOR IRRIGATION WORK. IRRIGATION SCHEDULE ITEM/SYMBOL MANUFACTURER/CAT # SHRUB/LAWN HEAD HUNTER PGM TYPE NOZZLES: .50, .75, 1 ' 0 1.5, 2.0 & 3.0; MODEL PGM-06-SHRUB, @ + MODEL PGM-04-LAWN, USE PGM-12 v4,� v4� _�l HEAD ADJACENT CURBS/SIDEWALK SHRUB/LAWN HEAD @ -zz- L SHRUB/LAWN HEAD 0 -ah- lk SHRUB/LAWN HEAD 0 -,=- L SHRUB/LAWN HEAD 0 _,n, k SHRUB/LAWN HEAD 0 )O� L SHRUB/LAWN HEAD 12 19 m SHRUB/LAWN HEAD L A, L SHRUB/LAWN HEAD 12 [!] CONTROL VALVE /-2-\ ligy CONTROLLER P.O.C. BACKFLOW PREVENTOR SHUT-OFF VALVE STRAINER QUICK COUPLER MAINLINE LATERALS SLEEVING MANUAL DRAIN RAINBIRD 1800-PRS-15 SERIES, MODEL 1804-LAWN, MODEL 1806-SHRUB, USE MODEL 1812 HEADS ADJACENT CURBS/ SIDEWALKS RAINBIRD 1800-PRS-12 SERIES, MODEL 1804-LAWN, MODEL 1806-SHRUB, USE MODEL 1812 HEADS ADJACENT CURBS/ SIDEWALKS RAINBIRD 1800-PRS-10 SERIES, MODEL 1804-LAWN, MODEL 1806-SHRUB, USE MODEL 1812 HEADS ADJACENT CURBS/ SIDEWALKS RAINBIRD 1800-PRS-8 SERIES, MODEL 1804-LAWN, MODEL 1806-SHRUB, USE MODEL 1812 HEADS ADJACENT CURBS/ SIDEWALKS RAINBIRD 1800-5 SERIES VAN, MODEL 5-VAN (USE APPROPRIATE ARC NOZZLES) USE MODEL 1804-LAWN, MODEL 1806-SHRUB, USE MODEL 1812 HEADS ADJACENT CURBS/SIDEWALKS RAINBIRD 1800-PRS-15 STRIP SERIES, NOZZLES 15 EST, 15 SST, & 9 SST; MODEL 1804-LAWN, MODEL 1806-SHRUB, USE MODEL 1812 HEADS ADJACENT CURBS/SIDEWALKS RAINBIRD 1800-PRS-15 VAN SERIES, MODEL 1804-LAWN, MODEL 1806-SHRUB, USE MODEL 1812 HEADS ADJACENT CURBS/SIDEWALKS RAINBIRD 1800 SERIES BRASS MPR NOZZLES; B15 STRIP SERIES, B15 EST, & B15 SST, MODEL 1804-LAWN, MODEL 1806-SHRUB, USE MODEL 1812 HEADS ADJACENT CURBS/SIDEWALKS RAINBIRD 100-PEB(1" VALVE ; 150-PEB (1-1/2" VALVE); & 200-P[4(2" VALVE) RAINBIRD ESP-16LXi POINT OF CONNECTION FEBCO 850 (1-1/2") AQUA (1-1/2") FEBCO (1-1/2") RAINBIRD 3RC 33K KEY/SH-0 ELL PVC -CLASS 200 PVC -CLASS 200 PVC -CLASS 200 (INSTALL SLEEVING UNDER ROAD IN THIS PHASE). CHAMPION 40 PSI, ADJUST RADIUS AS REQUIRED. USE IN ZONES WHERE OTHER HUNTER HEADSARE USED, 30 PSI, ADJUST RADIUS AS REQUIRED. USE IN ZONES WHERE OTHER RAINBIRD HEADS ARE USED, 30 PSI, ADJUST RADIUS AS REQUIRED. 30 PSI, ADJUST RADIUS AS REQUIRED. 30 PSI, ADJUST RADIUS AS REQUIRED. 30 PSI, ADJUST RADIUS AS REQUIRED, 30 PSI, ADJUST RADIUS AS REQUIRED. 30 PSI, ADJUST RADIUS AS REQUIRED. 30 PSI, ADJUST RADIUS AS REQUIRED. PLASTIC CONTROL VALVE WITH PRESSURE REGULATING FEATURES, INSTALL PER DETAIL & MANUFACTURES RECOMMENDATIONS. (1)16 STATION CONTROLLER; INSTALL IN LOCATION SHOWN ON PLAN. CONTRACTOR TO CONNECT EXEMPT 1-1/2" IRRIGATION WATER METER; PROVIDE AND INSTALL 2" SUPPLY LINE AND THREADED STUB OUT FOR IRRIGATION CONTRACTOR'S USE. BACKFLOW PREVENTOR DEVICE; INSTALL PER DETAIL. 200 PSI THREADED ENDS. INSTALL PER DETAIL. BRASS STRAINER W/100 MESH SCREEN. INSTALL PER DETAIL. INSTALL PER DETAIL @ P.O.C., PROVIDE (1) KEY AND (1) ELL. 2" SIZE OR SIZE AS NOTED. SIZES AS NOTED ON PLAN, 3/4" MIN. PROVIDE UNDER ALL HARD SURFACES. SLEEVES TWICE THE DIAMETER OF PIPE INSIDE. STRAIGHT RUNS ONLY. (SEE DETAIL). INSTALL AT THE LOW POINT IN EACH RUN OF PIPE. INSTALL PER DETAIL. ReW DEC -5 BUILDING DLEEPT. SHINGTON GISTERED (PE ARCHITECT), tificote No. 307 lifl"21, z 0 F- IL �j cn V) w x x X < X_ r) DRAWN: J. T. S. CHECK: C. P. JOB NO 98 1- < �E 04 0 77 < 00 < =0 'a 9 S2 L-1 LLI < 0 1­ ci 1 z LL_ Cf) 9 V6 SHEET: L2 OF: SHEETS PERMIT LANDSCAPE DETAILS IRRIGATION DETAILS HOSE WRAP WIRE AROUND STAKE TRUNK TWIST AND CUT ON INSIDE OF STAKE TWIST WIRE NOTES: NOTE: IRRIGATION CONTRACTOR TO USE APPROVED CITY OF BOTHELL DCVA ASSEMBLY 1. HOSE, REIFORCED RUBBER FOR IRRIGATION SYSTEM, SEE CITY OF BOTHELL STANDARD DETAIL #580, INTERLOCKED, LOOP AND TWIST 2. WIRE, 14 GA. GALV, WIRE — TIGHTEN WIRE DOUBLE STRAND) TWIST TO NOTE: FOR INSTALLATION OF POINT OF CONNECTION WITHIN A STRUCTURE REFER TO THE QUICK COUPLING VALVE SET Ld TIGHTEN. GENERAL CONTRACTOR AND MECHANICAL ENGINEER / CONTRACTOR, FLUSH WITH FINISH GRADE IN LAWN AREA 3' ABOVE 3. STAKE, 2' X 2' WOOD PRE —STAINED SIDEWALK-7-1 FINISH GRADE IN OTHER AREAS DARK BROWN, SPACED EVENLY NOTE ALL FITTINGS TO BE GALV. CURB, ETC, FINISH GRADE LAWN AREAS AROUND TREE OUTSIDE OF ROOTBALL. ZD PAINT ALL'GALVANIZED PIPE WITH ONE COAT 12' AX, 0 5/ NOTCH STAKE FOR WIRE, CARBON ELASTIC PAINT :D 4. TAPER MULCH THICKNESS DOWN IV FINISH GRADE SHRUB AREAS 2 . —IIT TO TOP OF ROOT MASS. 11= - Ld m Q� L'i F- CI) Ld 0 0� Ld Lo -J Ld w F- -J -J < < Lj U U �j 111� '11� u 0 0 AS REQ V � < I I— XEI I 77 x jj� IEI I MI I IHE , ) I 1= v 2 TIMES ROOT BALL OR ROOT BALL PLUS 30' TREE STAKING DETAIL NO SCALE 6_> 611 SHRUB ROOT BALL SAUCER Mill: I IEEI Eil EE M\ El I EE 'Z I Ed 111 51 I I—F,,L ROOT BALL PLUS 12' BOX AMETEK BOX AMETEK BOX AMETEK 12' ROUND PLASTIC BOX AND COVER ECONOMY ff �Ju M D 0 S DARD STAINLESS STEEL CLAMP TURF BOX BOX BOX SIZE AND LENGTH AS REQUIRED SCH. 80 PVC NIPPLE QUICK TREE WRAP, IF REQUIRED COUPLER PEA GRAVEL 3' 'PLE WIRE AND HOSE S! IG JOINT CH. 40 PVC 7 DOUBLE CHECK WOOD STAKE, 2 PER DECID., ELL ELBOW SCH. 40 PVC STREET ELBOW 3 PER CONIFER UNION -UNION UNION LL 74�E L L ,1X MULCH P.R.V. R 4' 90 PVC SUPPLY PLANTING SOIL 6' ELL ELL LINE (SxSxT) S, H. 80 PVC NIPPLE SIZE AND P.V.C. -91 TING ?u SLEEVE GATE FT TEE FIT LENGTH AS REQUIRED VALVE 2A :GURA\��L'. 3' NIPPLE AND ELL PE BERM AND BASIN 9' 4 - 6' X 6' X CU/FT EL L U14ION CONCRETE BLOCK A GRAVEL ER SCH. 80 MALE ADAPT 18, PVC SUPPLY LINE MAIN LINE OPEN BURLAP AND FOLD BACK TOP 1/3RD (AS REQUIRED) SCH. 40 PVC STREET ELBOW P4' DIAMETER DRAIN LINE RESSURE QUICK RUN 1. ... ..... 1-112' PVC PIPE STAKE COMPACTED MOUND TO POINT OF REDUCING COUPLING (SCH. 40 MIN. 36' LONG OR SUPPORT TREE METER CONNECTION BACKFLOW PREVENTER VALVE VALVE AS SITE REQUIRES TEST COCKS TO FACE UP FOR TESTING FOR WINTERIZATION TO BE SET FOR BLOW-OUT A14D NOTE: USE TEFLON TAPE ON ALL THREADED FITTINGS 70 PSI. PRESSURE TESTING CUT IN DETAIL TYPICAL QUICK COUPLING VALVE ASSEMBLY POINT OF CONNECTION NO SCALE INSTALLATION OF POINT OF CONNECTION OUTSIDE OF STRUCTURE MULCH PLANTING SOIL HARD SURFACE NOTE: FORM WATER SAUCER AROUND PLANT, TAPER SOIL AWAY FROM TOP OF ROOT MASS, SHRUB PLANTING DETAIL Q GALLON AND GREATER) NO SCALE GROUND COVER PLANTING SOIL ROOT BALL 12' MULCH DR E.Q. TO PLANf SPACING HARD SURFACE CU 1=1 I 1=1 I Ed I 1=1 I co NOTE: TAPER MULCH THICKNESS DOWN 8, TO TOP OF ROOT MASS. GROUND COVER DETAIL (4" POTS AND SMALLER) NO SCALE 4'X6' PRESSURE —TREATED DOUGLAS FIR HEADER #5 REBAR PLACED EVERY 2 1/2'-3'O.C. LAWN AREA Q: 0 C� C 0 0), 0<�D I 1=1 I EEI 11 1<��p j=j j J=j I J=� j 1=j CU Im WOOD HEADBOARD DETAIL NO SCALE - PVC MINIMUM TWO TIMES THE DIAMETER '18, 24' SLEEVE OF PIPE TO BE INSERTED INTO SLEE)E. TYPI TYP. PLANTER MAIN OR LATERAL STUB -UP AND PLUG WIRE WIRE SLEEVE (MINIMUM OF PLANTER-­­�. PAVIN TWO INCHES DIAMETER,) 'CUR'B A 18- 24 BUILDING TYP.1 TYP� ENTRY mommmom WALK­�, W IRE, MAIN 0 WIRE SLEEVE, R LATERAL SLEEVE- - - - MAIN OR LATERAL UJ CURB �11 z 24- 18 w < TYP. 'T4 -�z SIDEWALK <: -j WIRE SLEEVE CURB LINE OF CURB CURB OR WALK PLANTING PAVIN 75-�-IRRIGATION FLAG APE CLOSED j VERTICAL STUB -OUT _—MARKER PIPE OR 1, IRRIGATION WIRE TRENCH OR 2. METALIC TAPE D CU > 0 METALIC TAPE RRIGATION WIRE PVC SLEEVE MAIN LINE OR LATERLA LIN PVC EL TYPICAL SLEEVING DETAIL NO SCALE ROUND PLASTIC BOX AND COVER. COVER MARKED, IRRI GATE I ki <1, gn, L, 1-1/2' FINISH GRADE LAWN AREAS FINISH GRADE SHRUB AREAS HANDWHEEL PVC SUPPLY LINE PEA GRAVEL (MIN, 2 CU. FT,) q� GATE VALVE jq� ob PVC MALE o 00 ADAPTORS -Cp 0 0 Job .%�qi;,, -.0 4R3 NOTEi GATE VALVE SHALL BE INSTALLED IN SHRUB AREAS UNLESS OTHERWISE APPROVED, TYPICAL GATE VALVE ASSEMBLY NO SCALE (3' AND SMALLER) ff SIDEWALK, CURB, ETC, FINISH GRADE SPRINKLER NOZZLE PVC TEE OR ELBOW (SxSxT) POP-UP ASSEMBLY--/ (INSTALLED 1' ABOVE FINISH GRADE IN OPEN AREAS OR SCH. 40 PVC STREET EL13OW AS NOTED) SCH, 80 PVC NIPPLE (LENGHT AS REQUIRED) SCH. 40 PVC STREET ELBOW NOTE1 1. INSTALL HEAD FLUSH WITH TOP OF HARDSCAPE AT INTERSECTION AND CORNERS 2. USE TEFLON TAPE ON ALL THREADED FITTINGS, TYPICAL SHRUB HEAD POP-UP ASSEMBLY NO SCALE 6' OR AS SIDEWALK, NOTED c, CURB, ET� SPRINKLER NOZZLE 4 — TYPICAL BUILDING WALL POP-UP BODY ASSEMBLY (112' ABOVE FINISH GRADE) 24' MIN.. - AUTOMATIC CONTROLLER ASSEMBLY TO BE WALL MOUNTED FINISH GRADE - COMMON WIRE SHALL BE TIED INSIDE HOUSING WHEN REQUIRED ON - OFF SWITCH TO BE PROVIDED BY CONTRACTOR - STRAIGHT CONDULET FOR WIRING CONNECTIONS USING WIRE NUTS - ELECTRICAL CONDUIT TO INDEPENDENT PVC SCH. 80 NIPPLE (LENGTH AS REQUIRED) SOURCE (CONTROL UNIT ELECTRICAL REQUIREMENTS: 115V,, 60CYC, 2 AMPS MAX,) (S x S x T) NOTES: PVC TEE 1. COMMON WIRE TO BE WHITE AND CONTROL OR ELBOW LATERAL LINE (SIZE WIRE TO BE BLACK IN COLOR. AS NOTED ON DRAWING) 2. NO SPLICES SHALL BE MADE BETWEEN FINISH FLOOR CONTROLLER AND REMOTE CONTROL VALVE, 48' 3. CONTROL WIRING SEQUENCE CORRESPONDS SCH. 40 PVC STREET ELBOWS TO OPERATING SEQUENCE OF REMOTE CONTROL VALVES AND AUTOMATIC CONTROLLER UNIT STATION CONNECTION NDTEt USE TEFLON TAPE ON ALL THREADED FITTINGS (SEE IRRIGATION PLAN FOR CORRECT VALVE SEQUENCE), SLEEVE FOR CONTROL WIRES PROVIDED BY GENERAL CONTRACTOR (2) TYPICAL SHRUB HEAD ASSEMBLY ELECTRICAL TAPE - TAPE WIRINGS AT INTERVALS OF NO SCALE (POP-UP TYPE) 10 FEET ON CENTER CONTROL WIRING (AWG UF TO CONTROL UNIT AT TERMINALS) 1 CONTROL WIRE TO EACH R.C.V, I CONTROL WIRE TO ALL R,C.V,'S TYPICAL AUTOMATIC CONTROLLER ASSEMBLY NO SCALE (WALLVIOUNTED TYPE) J.R.-84 -TYP. SUPPLY LINE PVC STREET ELBOW,' TYP. PVC TEE (LINE SIZE) W/ 112' OUTLET DRAIN VALVE cyo 06, �? 755, '0- 00000000 0 ��a_ 080,0 0150Y&I 0 0000 dPI PEA GRAVEL (TYP. 2 CU, FT.) NOTE: CONTRACTOR TO VERIFY EXACT LOCATION TYPICAL DRAIN VALVE ASSEMBLY NO SCALE SIDEWALK, CURB, ETC, SPRINKLER NOZZLE POP-UP BODY ASSEMBLY (INSTALL 1/2' ABOVE FINISH GRADE) PVC SHC, 80 NIPPLE SIZE AS REQUIRED PVC SCH. 40 STREET ELBOW PVC SCH. 40 ELBOW 12' PVC TEE PVC SCH. 80 NIPPLE (SIZE S x S x T AS REQUIRED) IN FINAL OR ELBOW POSITION RISER SHALL BE AT A 45 DEGREE ANGLE PVC SCH. 40 STREET ELBOW LATERAL LINE (SIZE AS NOTED ON DRAWING) NOTE, USE TEFLON TAPE ON ALL THREADED FITTINGS TYPICAL LAWN HEAD ASSEMBLY NO SCALE SIDEWALK, CURB, BOX TO BE PLACED AT RIGHT ANGLE ETC. HARDSCAPE EDGE 12' OR 12'X18' PLASTIC BOX AND COVE AS NOTE WITHLOCK TOP CURL TYPE EXPANSION LOOP (MIN 2 A,4601 WATERPROOFED WIRE CONNECTION Ildi-7 CHRISTY'S I.D. TAG (STANDARD), NON -PRESSURE SECURE TO SOLENOID PIGTAIL A-- LINE FITTING FINISH GRADE /4 LAWN AREA Y PVC LINE PIPE FINISH GRADE SOLENOID 0 3' go C�, FLOW ADJUSTMENT .0 12' MAX.%p 0 CID 'CPO PEA GRAVEL (MIN, TOP IF VALVE 3 CU. FT.) 18' MIN,, PVC SCH. 40 MALE ADAPTOR (TYP. 2 PLACES) PVC LINE PIPE PVC ELBOW PVC LINE PIPE PVC SUPPLY LINE FITTING(SxSxT) COMMON WIRE NOTE: CONTROL WIRE 1, VALVES ARE TO BE INSTALLED IN SHRUB AREAS UNLESS OTHERWISE NOTED, 2. WHEN MORE THAN ONE VALVES IS LOCATED IN THE SAME AREA, PROVIDE A SPACE A MIN, OF 3 FEET APART, 3. USE TEFLON TAPE ON ALL THREADED FITTINGS, TYPICAL REMOTE CONTROL VALVE ASSEMBLY NO SCALE (STRAIGHT TYPE) LAWN AAAA A AAAA FINISH GRA MARLEX ELL SCH, 80 NIPPLE OR FUNNY PIPE MARLEX ELL PLANTING AREA RISER (POP-UP) DETAIL NO SCALE )9*0 EE]l 7`147 1,1" "i-TC-1) 0 E C - 5 2 -.031 BUILDING DEPT. INISH GRADE HEAD POP-UP PVC LATERAL PVC 'T' OR 'L' S TA TE OF WASHINGTON REG,ISTE 01 ANDSC RCHITECT a ons Certificate No. 307 W� w Lei C-m 10142 SHEET: L3 OF: SHEETS PFRkAIT D E B U 1 L D I iNll G D E-- P T. STREET FILE