24111 HWY 99 DOCESlo kVjv7 117Z RECLIVED JAN 141989 EI)MONDS FIRE DEFT. RT OF INSPECTION, INSPECTOR DATE 1. GE1 A a.' #ding o"Uple, see Is thd,'W <1 ording to information furnished by owner or owner " a repre K �s occ*pa cy same. as previousihspection according to information furnished by owner or C. "ail V 7:7�477,77,7� 77* 7,77, 77 Are, I systems in,service. d. '�all fi"re proteetion systenis Hante as last inspection aecording to information furnishei y Are' d b I � owner or OWTIer's represetitative? e. Is building completely spriijklered? f. Are all now additions'and building changes properly protected according to information fur,, by owner or owner's representative? g. -nished Is all stock or storage properly below sprinkler piping? h. Was property free of fires since last inspection according to information furnished by owner or owner's represcioative" (E.xplain any fire on separate sheet) i. In areas protected by wet system, does the building appear to be properly heated in all areas, including blind attics, perimeter areas and are all exterior openings proteeted against entrance, of cold air? 2. CONTROL VALVES (See Section 16) a. Are all sprinkler system main control valves open? b. Are all other valves -in proper position? c. Are al I I control valves in'good condition and sealed or supervised? 3. WATER' SUPPLIES, (See Section 17) a. Was a water flow test made and results satisfactory? 30 4. TANKS., PUMPS. FIRE DEPT, CONNECTIONS a. Are fire pumps, gravity tanks, re:;rvoirs and pressure tanks in good condition and prop- erly maintained? b. Are fire dept. connections in sati,,sractory condition, couplings free, caps in place and check y SHEET 1 OF 2 Inspeftion Contract No. t-14- !� - / ! Z / Bureau File No. V ". V 5. WET,SYSTEMS (See Section 13) Y. b. Haveartti-freeze, systems been tvsted and left in c. Are alarm valves, water -flow indicators and retards in satisfactory condition? 6. DRY SYSTEMS (See. Section 14) a. Is dry valve in service and in good condition? b. 'Is air pressure and priming water,level C. Is air compressor in good condition7 d. Were low points drained during fall and winter in spections? e. Are quick -opening devices in service?, f. Have dry�valves been trip tested satisfactorily as required? 9. Are dry valves adequately protected from freezing? h. Are valve house and heater condition satisfactory? 7. SPECIAL SYSTEMS (See Section 18) a. Were valves tested as required? b. Were- all heat responsive systems tested and results satisfactory? C. Were supervisory features tested and results satisfactory? $. ALARMS, J a, Are water motor and gong test satisfactory? ...... b. Is electric rA4rr.4 test satis(ictory? J 3T C. Is supem-ooiy 'alarm,service test satisfactory? Cto 40 J�l Sp LIERS — PIPING Ye a, Are *1 +rinklers in good condition, not obstructed, and free of corrosion 'Are or loading? "�Q b. all sprinklers less than 50 years old? �6tra C. A re sprinklers readily available? d. Is condition of piping, drain valves, check valves, hangers, pressure gages, open sprin- klers, strainers satisfactory? 01 e. Have sprinklers been checked for proper temperature rating? f. Are portable fire extinguishers in good condition? gd g. Is hand hose on sprinkler systems satisfactory? to. Date Dry -system Piping last checked for stoppage. 11. Date Dry -system Piping last checked for proper pitch. Z - -1 *7 12. Date Dry'_pipa� Y-alvelait trip tested. 13. W** Systems! No? Make and.-Modbl? e t4. Dry Systev*, No? Ma*e and Model?—' J, 15. special Syptq, ype 4NMI Make and Condition? — Open Ves Secured Cl dd Sign 0"M *0 16. CONTROL VALVE. 0? 0 T 0 Ci;; Connection &n;lpol Valve Tank Control Valves Pump Control Valves Sectional Control Valves )e System Control Valves, 4 T-1 SHEET 2 OF 2 N.A. t No* 00 00 ."XI 17. WATER -FLOW TEST Water Pressure? CITY- 00" PSI !i' 0 TANK —PSI —FIRE ft Water -flow Test? (If none made, why?) Size Pressure Flow Pressure Size Pre*su' Flp* sau re Ptc Test Pipe Located Test Pipe Before Pressure After Test Pipe Located Test Pipe Before Pres r,�:.. Af A sz 18. Heat Responsive Devices: Type? oev /',q, Type of test" 1walve No —A—B—C—D—E—F— Valve No- A—B C—D E _F Valve No. A_B_C_D_E_F__ Valve No.—A—B—C—D E—F E Valve No. A—B—C—D _E_F —Valve No —A B—C D _F_ Valve No. —A—B—C—D _E_F —Valve No.—A—B—C—D E—F t Results?, Te! Auziia�r:'y �qiiro -m-, 19. Explanation of iny"'No" answers. o &"4.t4,4,� V (41, �e, 'ZI If Pd e t &r A 20. Recent changes in building occupancy or fire protection equipment. 21. Adjustments or corrections made. 22. Desirable improvements. et'l-441a 4 DUPLICATE TO: 105hAndurAll STREET CITY STATE "K 6 V, �w� 'a NA, DRY PIPE VALVE TRIP TEST REPORT TRIANGLE FIRE PROTECTION P.O. BOX 264 WOODINVILLE, WASH. 98072 bad— 447 City state contlact No. -rlIF Oak d Up Test lespectof 5 Day Work No. NOTEm BEFORE ANY DRY lnpt V^LVIC 15 TMP TESTED* THE WATER SUPPLY LINE TO IT SHOULD Ot THOROUGHLY mumm vw Two Inc" DRA'" ISCLOWTHIC VALVIC SHOULD Or OPENED WIDE. AND WATER AT rULL PRESSURE SHOULD BE DI&CmAptaft UNA CHOUGH TO CLEAR THlE PIPE or Any ACCvwuL.ATiom or SCALE opt romEiGH MATCRIAL. Ir THERE :3 A HYDRANT ON TV& 41100ftV LINE.TPUS XYDRANT SHOULD Sit LMC scrofte THE TWO IACH OMAIN 18 OPENED. THE DRIP VALVE ON THE DI%y pM V*Lvg IIHOULDSE CNECKED ffirmar VaTimmolulim WOW � �ft' ... — — -- — - - .. - -- - - — DRY PIPE VALVES SYSTEM NO. I SYSTEM NO. SYSTEM No. VALVS 0XIIIIAL NUMOSO MANUPACTURCR 4%AMvtI C7 T-*'�&-- VALVl moDgL . ....... I VALV9 812'a INC" INC04 INC" — INCH CONTR 0 LLINO Avrefts paic, SpItINKLItas lNumegal —XIF JAPPONOXI IAPPROKI 4'% Pool a x I OATC LAST TRIP T9671tal OAT9 LAST OPERATC010 Ssup& :111ORK AIR Los LOS Los Los TxmT WATCO LOS Los LOS Los 8122 AND LOCATION OF TEST VA6va "AN SAT9 VALV9 SICLOW D"V VALV9 OPaN WIDIL A T Ttly* top NOT. 14 W MANV vultodoll &in P"assuall Los LOS Los LOS WAT&M VQCq&Ufsa, 4TV Lee Los Lee LOS WAT6111 TRIPPSD AT Tima 00#4 140 SIEC MIN SIEC MIN sac WIN sac IF 9 ST11A FLOODED. LIST TIMIL Wj%lf8Ij ne.�Nap TEST OPCNIwQ ISO' 09C M I N --�S IE C MIN PERFORMANCE INV 914110" or *Dow MOVING PARTS VALV& CONDITION stuallcm FACING SCATS &-,& 01 L S9 T V ' DID ALARMS OPCPI^Ya AT TRIP ?a$?? -------- A LL LOW POINT DRAINS BLOWN OUTI . . ........ W^T6P CONTROL VALVC LEFT ALANbA C0NTp0�-'V#L -G 0 u I CK '�O- P� E �Hl N- D E V I C f S SYSS um, i Jf ;YSTEm No. SYSTIE#A No. Y$TgM NO- DIEVIC6 112,01AL NUMSER 001ANUFACTURKIIII (NAL41t) TVPC AND MODEL Los ----------- LOS -------------- Los AIR PORISURK 104 VPPCft C "AMOCO OUICK epa"ING Davica Talopgo AT Los sac sac Let IslitFORMANCE r V, QUICK Q ENING D Cot LF.IrT.104 sa"VICK AND CONTROL CP:. AP40 SIEALErl _ LIST ANY UNSATISFACTORY CONDITIONSI lor REMARKSi 4 iW17 FQEIIIEIT - 0 110 VCHITECTeS, INC., PeS. Evergreen One, 10940 NE 33rd Place, Suite 202, Bellevue, WA 98004 (206) 827-2100 Date: Tuesday, May 31, 1988 Mr. Gary McComas Fire Marshal City of Edmonds Civic Center Edmonds, Washington 98020 Project: Pacific Discount Center Edmonds, Washington job No: 87.175 Dear Gary; As per our recent telephone conversation on Tuesday, May 31, 1988. 1 am confirming that the General Note #46 is being deleted from the construction documents. A reflected ceiling plan will not be required for the permit process. Please feel free to contact meshould you need any additional information. Sincerely, Dean Steven Madson RECEIVED Freiheit and Ho Architects, Inc., P.S. JUN 2 1988 cc: Mr. Robert Siew EDMONDS FIRE DEPT. CITY 01=413MONDS CIVIC CENTER * EDMONDS, WASHINGTON 98020 - (206) 775-2525 FIRE DEPARTMENT LOCATION: 243.11. 99 BUSINESS NAME: DOCIKS MERCANTIL.1--- MAIJ MAILING 24111 1-416'HWAY 99 ADDRESS ElIMONDS WA 98020 BUSINESS OWNER: EASTERN lNVESTMEXT' CORP FIRE PREVENTION SAFETY SURVEY PHONE: 775-721.2 FREQUENCY I SHIFT 11 STATION A R — 12 SCHEDULED DATE DUE 110 UFIRIio 41;5403 1. OFJO 1. 46 HOME PHONE: 206---455--9993 EMERGENCY-1: ,*..,)*.rr.::w KEY ACCESS-2: R HOME PHONE: HOME PHONE: 643-91.77 LETTER YES NO NEEDED El 0- PERSON CONTACTED: NAME OF INSPECTOR: 1-v oca INITIAL INSPECTION DATE HfARI )-5 FOUND 1E -� fi:' -RUT. 1 (.3 1 RE. F HOOD SYS/ 040 ENTER CODE ONLY ONqE- Wl:- -7 SYSo C0NF':KlIF:NC.A".: TEST:I:N6 DOCUMENTATION A31REl) R0. L..:I:'Y'ES/ STANDPlPE/ SYS/ Al ARM SYS'/ VIOLATION CODE TE L - -1V E D Al I -3.0-tqu- IIST REINSPECTION DATE DUE: (RESERVED AREA I 2ND REINSPECTION DATE DUE: (RESERVED AREA I 3RD REINSPECTION DATE DUE: INSPECTOR: INSPECTOR: INSPECTOR: PERSON CONTACTED: PERSON CONTACTED: PERSON CONTACTED: DATE: DATE: DATE: VIOLATIONS VIOLATIONS VIOLATIONS LETTER NEEDED []YES []NO LETTER NEEDED [I YES ONO LETTER NEEDED FIRE DEPARTMENT COPY Ll 101 CITY OF EDMONDS CIVIC CENTER - EDMONDS, WASHINGTON 98020 - (206) 775-2525 FIRE DEPARTMENT Mr. Joe Surace, Manager Seattle Skating Bingo 24111 Highway 99 Edmonds, WA 98020 Dear Mr. Surace, March 19, 1986 LARRY S. NAUGHTEN MAYOR SUBJECT: SEATTLE SKATING BINGO, 24111 HIGHWAY 99, EDMONDS, WA On March 18, 1986 members of the Edmonds Fire Department' conducted a walk-through of your building. Our objective is to observe any.problems in common areas such as exits and hallways, and coordinate their repair with the building's management. During the inspection, the following problems were noted: 1. Exit lights inoperative above northeast exit door, northwest exit door, and south exit door. 2. East exit door: 1) Partially blocked with chairs and storage material, 2) Area just outside obstructed by garbage bags. 3. Remove sign blocking exit corridor just outside south exit door. Since all the items noted during the inspection are Life Safety Requirements, it is very important that they all -be cor- rected immediately. A reinspection will be scheduled for March 28, 1986. 0 'nu If you have any questions, 233, Monday through Friday. !V11 4-:000" GLM: be please call me at 775-2525, Ext. Sincerely, C nA Gary L. McComas Fire Marshal INCORPORATED AUGUBT 11, IB90 Aff)I;J �DJD cDhL20 llvL),,,-2EW19�7?v�F lq6ov�F A1167 6:w 7*- ae r 000e - ZDOOe, /Ow F"<,I, DOL OL., /-,7-/ CX1, OLJ 7:5-10F 40-&-5-7r!)CR;6 6LOCZIvi:�� Z�V.l 7- e D AeelDd 8 EY/7 DDOe-, A/? l-/ —770 Po-s DA�6 1,6' A) J�V ItV /VV'Ol-, j 041 410094 C�-9,Y7- C'9117— P-12 ML m MCI- CITY OF EDMONDS LARRY S. NAUGHTEN CIVIC CENTER - EDMONDS, WASHINGTON 98020 - (206) 775-2525 MAYOR FIRE DEPARTMENT November 18, 1985 Paul Doce. Dean Doce 24111 Highway 99 Edmonds, WA 98020 G. John Doce 4432-55th N. E. Seattle, WA 98105 Dear Sirs: During a recent drive past your building, I noticed that the sprinkler system valves and connections have been overgrown with blackberries. I must request that the brush be removed as soon as possible. If you have any questions, please call me at 775-2525, Ext. 233, Monday through Friday. Sincerely, C� - 9n cen"o-z-) McComas Gar Fire Marshal GLM: be 710 UNIFORM MECHANICAL CODE 1982 EDITION 801-803 level platform. When the roof has a slope greater than 4 in 12, a level working platform at least 30 inches in depth shall be provided along the firebox and control sides of the furnace. Sides of a working platform facing the roof edge below shall be protected I by a substantial railing 42 inches in height with vertical rails not more than 21 inches apart, except that parapets at least 24 inches in height may be utilized in lieu of rails or guards. (f) Catwalk. Except on roofs having a slope less than 4 in 12, a catwalk at least 16 inches in width with substantial cleats spaced not more than 16 inches apart shall be provided from the roof access to the working platform at the appliance. (g) Roof Access Scuttle. Required working platforms, railings and catwalks may be omitted when access to the equipment is through a required roof scuttle and all of the following provisions are met: 1. The required scuttle is located immediately adjacent to the control side of the equipment unit. 2. Controls, filters, burners, fans and motors are accessible for service and repair within 2 feet of the edge of the equipment platform on the scuttle side. 3. The equipment platform is not more than 20 inches above the high side of the scuttle opening. 4. A substantial working platform not less than 30 inches by 30 inches shall be provided directly below (lie scuttle at a point not less than 30 inches or more than 32 inches below the high side of the scuttle opening. 5. Scuttles located on other than the roof incline side of the equipment unit shall have the hatch hinged on the low side of the scuttle. Hatches shall be equipped.with means to ensure an opening radius of not less than 90 nor more than 100 degrees from the closed position. Hatches and hardware, when open, shall be capable of withstanding a 300-pound lateral force from the roof incline side. 6. Access to scuttles shall comply with Section 708. (h) AcFess. Every furnace installed in or on an exterior wall of a building, which is designed so that the burners or controls must be serviced from outside the building, shall be readily accessible. Every furnace located on the roof of any building shall be readily accessible. EXCEPTIONS: 1. Permanent exterior ladders providing roof access need not extend closer than 8 feet to the finish grade. 2. A portable ladder may be used for access for furnaces on the single -story portion of a Group M or R Occupancy. 60 Chapter 8 VENTED DECORATIVE APPLIANCES, FLOOR FURNACES, VENTED WALL FURNACES, UNIT HEATERS AND ROOM HEATERS Scope Sec. 801. In addition to the requirements of Chapter 5, every vented decora- tive appliance, floor furnace, vented wall furnace, unit heater and room heater shall comply with the applicable requirements of this chapter. General I Sec. 802. Every vented decorati�e appliance, floor furnace, vented wall fur- nace, unit heater and room heater shall be of a type listed for vented use and shall be connected to a vent complying with Chapter 9, except as provided for in Section 807. Every vented decorative appliance, floor furnace, vented wall furnace, unit heater and room heater shall be provided with combustion air supply complying with Chapter 6. A vented decorative appliance, floor furnace, vented wall furnace, unit heater or room heater shall not be located in any of the following places: I . In any surgical operating room. 2. Under any stairway. 3. In any hazardous location. 4. In any Group H, Division 1, 2 or 3 Occupancy. 5. In any room or space where an open flame is prohibited. 6. In Group H, Division 4 Occupancies, devices generating a spark or glow capable of igniting gasoline vapors shall not be installed or used within 18 inches of the floor. 7. In any Group H, Division 5 Occupancy, and Group B, Division 3 Occupan- cy, unless the appliance is located at least 8 feet above the floor. Overhead heaters installed in aircraft storage or servicing areas of Group B, Division 3 Occupancies shall be at least 10 feet above the upper surface of wings or engine enclosures of the highest aircraft which may be housed in the hangar. Overhead heaters shal I be at least 8 feet above the floor of shops, offices and other sections of hangars communicating with aircraft storage or working areas. Vented decorative appliances, floor furnaces, vented wall furnaces, unit heat- ers and room heaters shall be installed so as to minimize the probability of damage from an external source. Vented Decorative Appilances . Sec. 803. In addition to the gener�l requirements specified in Section 802, e . very vented decorative appliance shall comply with the requirements specified for heating equipment and heating appliances of this code. Approved gas logs may be installed only in solid -fuel -burning fireplaces, provided: 61 803-805 UNIFORM MECHANICAL CODE 1982 EDITION 805-806 0 1-1 A 1. The gas log is installed only in accordance with the manufacturer's instructions. 2. If the fireplace is equipped with a damper, it shall be permanently blocked open to a sufficient amount to prevent spillage of com.bustion products into the room. 3. The minimum flue passageway shall be not less than I square inch per 2000 Btu/h input. 4. Gas logs when equipped with a pilot shall have a listed safety shutoff valve. Floor Furnaces See. 804. (a) Placement. In installations utilizing flat floor furnaces, at least 6 inches clearance from wall surfaces shall be maintained. Flat floor furnaces shall be located so as to provide at least 24 inches clear space on two adjoining sides of the installation. Wall -register -type floor furnaces shall be located at least 6 inches from inside wall corners. EXCEPTION: Replacement floor furnaces of the same or lesser Btu/h input rating may be installed in the same location as the replaced furnace when such replacement does not create an unsafe condition. Doors shall be located so that no part swings within 12 inches of the grille openings of a floor furnace. Door stops and door closers shall not be relied upon to provide the required separation. Projections extending over floor furnaces shall be located at least 5 feet vertically above the wari-n-air grille. Neither flat nor wall -register -type floor furnaces shall be located in the floor or wall of an aisle, foyer, corridor or exit other than in a dwelling unit. Floor furnace locations shall be selected so that the burner assembly projects into unoccupied under -floor space. (b) Access. An opening and passageway not less than 24 inches by 18 inches shall be provided to floor furnaces. Passageways shall be not more than 20 feet in length from the required access opening or from an under -floor area having at least 30 inches height. (c) Installation. Floor furnaces shall be supported independently of the fur- nace floor grille. Floor furnaces shall be not closer than 6 inches to the ground. EXCEPTION: Where the lower 6-inch portion of such furnace is sealed by the manufacturer to prevent entrance of water, such clearance may be reduced to 2 inches. When it is necessary to excavate to install a floor furnace, the excavation shall extend 30 inches beyond the control side of the floor furnace and 12 inches beyond the remaining sides and the back. Excavations required by this subsection shall slope outward from the perimeter of the base of the excavation to the natural grade under that portion of the building at an angle not exceeding 45 degrees from horizontal. Floor furnaces shall not be installed on a concrete slab on grade. Vented Wall Furnaces Sec. 805. (a) Location. Vented wall furnaces designed to be installed in a 62 nominal 4-inch wall shall be not less than 6 inches from an inside room corner unless listed for lesser clearances. EXCEPTION: Replacement of vented wall furnaces of the same or lesser Btu/h input rating may be installed in the same location as the old furnace if it does not create an unsafe condition. Every vented wall furnace shall be located so that a door cannot swing to within less than 12 inches of any air inlet or air outlet of such furnace measured at right angles to the opening. Doorstops or door closers shall not be installed to obtain this clearance. Except when specifically approved, vented wall furnaces shall be installed at least 18 inches below any structural projection. This requirement includes doors and windows which could project over the furnace. (b) Combustion Air. Every vented wall furnace shall be provided with com- bustion air supply complying with Chapter 6. EXCEPTION: The required combustion air openings may be omitted to any area in which a vented wall furnace is installed, provided there is a permanent cased opening or archway through which a person may walk, opening into other rooms having a combined volume in cubic feet equivalent to 1Ao of the Btu/h input rating of such furnace. (c) Limitations. Ducts shall not be attached to wall furnaces. Casing exten- sions or boots may be installed, if listed as part of the appliance. Unit Heaters Sec. 806. (a) Suspended -type Unit Heaters. Suspended -type unit heaters shall be installed as follows: 1. Safely and securely supported with hangers and brackets of noncombustible material., 2. With clearances from combustible material of not less than 18 inches at the sides, 12 inches at the bottom, 6 inches above the top and 18 inches beyond the front and rear of the heater, except as provided in Subsections (c) and (d) of this section. (b) Floor -mounted -type Unit Heaters. Floor -mounted -type unit heaters shall be installed as follows: 1. With clearances from combustible material as set forth in Table No. 5-A, except -as provided in Subsections (c) and.(d) of this section. 2. On,combustible floors if approved for such installation. (c) Unit Heaters Listed for Reduced Clearances. Unit heaters listed for reduced clearances may be installed at the clearances indicated on the required manufacturer's label. (d) Unit Heaters Listed for Greater Clearances. Unit heaters listed for a greater clearance shall be installed to conform with conditions of approval. (e) High -static Pressur�-type Unit Heaters. High -static pressurc-type unit heaters with provisions for duct connections may be connected to ducts. provided: 1. All air inlets and air outlets are located in the same space as the unit heater. 63 806-807 UNIFORM MECHANICAL CODE 1982 EDITION 807 2. Every duct and plenum shall conform with the requirements as specified in Chapter 10 of this code - (f) Unit Illeaters Installed in Group B Occupancies. Unit heaters installed in a Group B, Division I or 3 Occupancy shall obtain recirculating air more than 4 feet above the floor. Room Heaters Sec. 807. (a) Vented Freestanding. Vented freestanding room heaters shall be installed with clearances from combustible material as set forth in Table No. 5-A. EXCEPTION: Heaters listed for reduced clearances may be installed at the clearances specified on the required manufacturer's label. Vented freestanding room heaters shall not be located so that a door can swing to within less than 12 inches of any wann-air outlet of the heater, measured at right angles to the outlet. Doorstops or door closers shall not be instal led to obtain such clearance. Vented freestanding room heaters shall be located at least 36 inches below any part of a structure projecting over the heater. This projection shall include doors or windows that could project over the heater. Vented freestanding room heaters shall be safely and securely installed to prevent accidental displacement. (b) Vented Overhead. Vented overhead room heaters shall be safely and securely supported with hangers and brackets of noncombustible material and shall be installed with clearances from combustible material as specified on the required manufacturer's label. EXCEPTION: Installation of overhead heaters in aircraft storage or servicing areas of Group B, Division 3 Occupancies shall comply with requirements of -- Section 802. (c) Unvented. Unvented fuel -burning room heaters shall not be installed, used, maintained or permitted 'to exist in any Group I or R Occupancy nor shall any such heater be installed in any building, whether as a new or as a replacement installation, unless permitted by this section. Listed or approved unvented overhead room heaters may be installed in any Group A, Division 2, 2.1, 3 or 4; Groups B, H, Division 4; Group H, Division 5, or Group M Occupancy, provided the installation conforms to all of the following requirements: 1. All portions of the heater are located not less than 8 feet above the floor. 2. At least two unobstructed permanent ventilation openings are provided to the room or space containing such heaters. These openings shall open directly to the outside of the building through the floor, roof or wall.The minimum combined total area of these openings shall be at least I square inch -for each 1000 Btu/h input of the heater or heaters, with a minimum total area of 100 square inches. One half of the required ventilation openings shall be above the heater or heaters and one half shall be located below the heater or heaters. EXCEPTION: Where approved by the building official, provisions may be made to exhaust the products of combustion to outside the building by mechanical means. 3. The heater shall be safely and securely supported with hangers and brackets of noncombustible material and installed with clearances from combus- tible material as specified on the required manufacturer's label. 64 65 A'L" / . /L b;u� 250 5th AVE. N. - EDMONDS, WASHINGTON 98020 * (206) 771-3202 BUILDING January 22, 1985 Paul Doceo Dean Doce# 24-1-1-1 Highway 99 Edmonds, WA 98020 G. John Doce* 4432 55th N.E. Seattle, WA 98105 Dear Sirs: LARRY S. NAUGHTEN MAYOR RECEIVED JAN 2 3 1-985 EDMONDS FIRE DEPT. It has come to the attention of the Building Department that you are installing partitions, barricades, fences, etc. throughout the retail building at 24111 Highway 99, some of which are in violation of your approved exiting plan, and UBC Section 3304, which prohibits the use of locks or latches on interior doors within the exit pathway. These locks and latches must be removed or provided with approved panic hardware immediately. The City has been most patient and lenient in the past with your continued code violations. However, if this item is not corrected and the City notified to reinspect by Thursday, January 24, 1985, we have no choice but to have the establishment closed until compliance is accomplished. If you have any questions, please contact me. HR/cr cc: City Attorney Mayor Naughten -IJA aAo-eL AD'L"e'a— Harold Reeves Building Official E CITY OF EDMONDS LARRY S. NALIGHTEN MAYOR CIVIC CENTER * EDMONDS, WASHINGTON 98020 * (206) 775-2525 FIRE DEPARTMENT January 13,1985 Mr. Jeff Lyon Action Screen Print 23637 HWY 99 Edmonds,Wa 98020 Dear Mr. Lyon SUBJECT: FIRE SAFETY FOR YOUR OPERATION AT 24111 HWY 99 On November 28,1985 while attempting to sign off the most current remodel.permits within the Doce building your silk screening business was discovered. During the inspection of your space several problems were discovered. The 55gal drum of acetone was removed shortly after the inspection wich greatly reduced the hazard but this still left several items to be corrected; l.Flammable liquids shall be limited to 5gal and must be stored in their original containers. 2.An approved metal container shall be provided for the storage of rags that have been used with flammable liquids. 3.Ventilation must be provided capable of four air changes per hour. 4.A portable fire extinguisher must be provided for your space.The extinguisher must have a minimum rating of 2,A-10,B:C. If you have any questions or if we can be of any assistance please call me at 775-2525, Ext.233 Sincerely, Gary McComas Fire Marshal CITY OF EDMONDS LARRY S. NALIGHTEN CIVIC CENTER - EDMONDS. WASHINGTIDN 98020 - (206) 775-2525 MAYOR FIRE DEPARTMENT December 51 1984 Mr. Jeff Lyon Action Screen Print 1123-5th Avenue S., #8 Edmonds, WA 98020 Dear Mr. Lyon, SUBJECT: OPERATION OF A H-2 OCCUPANCY IN A B-2 BUILDING On November 28, 1984, while conducting an insDection of Doces Building located at 24111 Highway 99, Action Screen Print was found in violation of the Uniform Building and Uniform Fire Code. On November 29, 1984 contact was made with one of the owners, Mr. Jeff Lyon, and at that time he was advised to re -- move all Class 1-A liquids from -his business. -Mr. Lyon. acknowledged the violation and agreed to comply. The Doce's Building is classified as an A-2.1 and also a B-2 occupancy. These classifications are: -A-i>f�Any building or portion of a building having.an assembly room with an occupant load of 300 or more without a stage. B-2 Drinking and dining establishments having an occupant load of less than 50, wholesale and retail stores, office building, printing plants, municipal police and fire stations, factories and workshops using materials not highly flammable or combustible, etc... Uniform Building Code, Section 708, Paragraph 2: Storage of volatile flammable liquids shall not be allowed in Group B, Division 1, 2, or 3 occupancies, etc ..... Considering the use of 1-A type liquids, your business falls into a H-2 classification. In order to resume your operation Mr. Jeff Lyon Deceinber 5, 1984 Page 2 and be in compliance with the code, the following list will.give you some idea of the measures you must take: 1. Move the business to the first floor. 2. Provide a 1-hour separation between your business and the rest of the building. 3. Provide an approved exhaust ventilation system. If you have any questions or if we can be of any assistance, please call me at 775-2525, Ext. 233. Sincerely, jGa McComas Fire Marshal GLM: be cc: Building Department File 7 25 P05 "J RECEIPT FOR CERTIFIED MIAIL 'E COVEIIAGE fflOVIDELI— r4() iNSUIIANG NOT FOR INT t:RNA1 IONAL MAIL (Sec, Revolte) mt. Jcff Action $crg�en- Print. STREET AND NO 1123- 5th. Ave.. -S - #8- P.O., STATE AND CODE Edwnds, WA 9802 POSTAGE CERTIFIED FEE SPECIAL DELIVERY —A cs i Fft-c-ilffb ffU;7E� T- !',jjUtJ 10 WjiOtA AND OAI E Dh,IVEHFD 0 SHOW 10WHOM,OA11. Atli) ADDRESS 01* I) IV SHOW TO WHOM ANL imAl I. 'D Wi fH RES-,RICFE DEJ-1VERI,. C5 DELIvERY fE C. V�'�OM, D JE ANO W ADDRESS OF DELI,, ERY WIT H 1) L, REST RIC TED DELIVERY TOTAL POSTAGE AND FEES V&STV,�F ORDiTE 00 E U1 5 7 6 70 P05 I-) Z g m 1 rn I a F SENDER: ComPlete items 1. 2. and 3. Add Yow address in the "RETURN TO" space an COMM 1. The following wrvice. is requested (check one.) 0 Show to whom and date delivered.. 4 Show to whorn, date m-,d addran of L;e'r, Y. CYRESTIUCTED DELIVERY Show to whorn and date delivered ............ —4 0 RESTRJCTED DELIVERY. Show to whorn, date, and address of delivery.$ — (CONSULT POSTMASTER FOR FEES) 2. ARTICLE. ADDRESSED TOME Jeff—L—yon Action Screen Print 1123-5th Ave. S., #8 Edmonds, WA 98020 3. ARTICLE DESCRIPTIOAI: REGISTERED NO. UM WSURED NO. �CERTJFIIED 56257674 I Wways, obtain sigmiture of addremo or agent) I have received the article described above. SIGNATURE DAddressee OAutburl" "eet 4. =cOATEOF DE LIVERY P 0STMARK 5. ADDRESS Manwim only 0 nmeamed) - - I 6. UNABLE TO DELIVER BECAUSE. CLERKS I I INITIALS 0 CITY OF EOMONOB CIVIC CENTER - EDMONDS, WASHINGTDN 98020 - (206) 775-2525 FIRE DEPARTMENT Mr. Jeff Lyon Action Screen Print 1123-5th Avenue S., #8 Edmonds, WA 98020 Dear Mr. Lyon, 0 December 5, 1984 LARRY S. NAUGHTEN MAYOR SUBJECT: OPERATION OF A H-2 OCCUPANCY IN A B-2 BUILDING On November 28, 1984, while conducting an inSDection of Doces. Building located at 24111 Highway 99, Action �creen Printwas found in violation of the Uniform Building and Uniform Fire Code. On November 29, 1984 contact was made with one of the owners, Mr. Jeff Lyon, and at that time he was advised to re- move all Class 1-A liquids from his business. Mr. Lyon acknowledged the violation and agreed to comply. The Doce's Building is classified as an A-2.1 and also a B-2 occupancy. These classifications are: A-2.1 Any building or portion of a building having.an assembly room with an occupant load of 300 or more without a stage. B-2 Drinking and dining establishments having an occupant load of less than 50, wholesale and retail stores, office building, printing plants, municipal police and fire stations, factories.and workshops using materials not highly flammable or combustible, etc... Uniform Building Code, Section 708, Paragraph 2: Storage of volatile flammable liquids shall not be allowed in Group B, Division 1, 2, or 3 occupancies, etc ..... Considering the use of 1-A type liquids, your business falls into a H-2 classification. In order to resume your operation F�- 4 Mr. Jeff Lyon ,,Dec�mber 5, 1984 Page 2 and be in compliance with the code, the following list will give you some idea of the measures you must take: 1. Move the business to the first floor. 2. Provide a 1-hour separation between your business and the rest of the building. 3. Provide an approved exhaust ventilation system. If you have any questions or if we can be of any assistance, please call me at 775-2525, Ext. 233. GLM: b e cc: Building Department File Sincerely, G McComas Fire Marshal November 29, 1984 MEMO TO: Doce's File SUBJECT: FINAL INSPECTION OF COMMERCIAL REMODEL AND TENNANT IMPROVEMENTS At the request of the Building Official and Mr. Dean Doce, an inspection was initiated to determine compliance with permit requirements. The following items were noted during a partial inspection conducted on November 28, 1984: 1. Silk Screen Business - on the second floor, southeast corne r a. Unknown quantity of flammable liquids.. b. Electrical.is not suited for atmosphere. c. Improper transfer of liquids (flammable) and storage. 2. Stairs to second flo.or in southeast corner. a. Complete underneath of stairs. This area must be sheetrocked and taped. b. Removesprings and other overhead door apparatus protruding through this enclosure. 3. Repair damaged sprinkler system pipe near southeast corner of first floor. 4. Provide adequate electrical distribution points for tennants. The use of extension cords is not permited. 5. Service fire extinguishers - this must be done annually., 6. All exit doors secured with.dead bolt locks shall have a sign affixed stating "This Door To Remain Unlocked During Business Hours.:" This sign shall be in letters not less than I inch on a contrasting background. 7. Sea West Furniture a. Provide on 4.-A,40-B:C, dry chemical fire extin- guisher. It shall be located on the post neares.t -the double exit doors. Doce's File November 29, 1984 Page 2 8. B.ingo Room a. Remove drape from' exit sign in northeast corner of room. b. Provide permanent outlets for T V monitors and eliminate.extension cords. c. Provide proper bracket for fire extinguisher near northeast corner. 9. Electrical a. Label all panels. b. Replace all switch,.outlet and panels -where appropriate This is not a complete list becuase the inspection,was termin- ated prior to completion. GLM: be W.4 JEWT779 M August 27, 1984 MEMO TO: Hal Reeves Building Official FROM: Gary L. McComas Fire Marshal SUBJECT: -CHANGES TO APPROVED PLANS FOR DOCE'S REMODEL AT 24111 HIGHWAY 99 After review, the fire department has no objections or comment. GLM: be M.m-11 July 19, 1984 MEMO TO: Hal Reeves Building Official FROM: Gary L. McComas Fire Marshal SUBJECT: DOCE'S REMODEL After review of the most recent plans, it appears that all Life Safety requirements are met. GLM: be a international Conference Building Officials REGIONAL OFFICE: 17544 MIDVALE AVENUE N., SUITE 304 - SEATTLE, WASHINGTON 98133 - (206) 542-9421 BOARD OF DIRECTORS PRESIDENT JACK S. ATKINS. P.E. BUILDING OFFICIAL' DEVELOPMENT SERVICES DIRECTOR PLACERVILLE. CALIFORNIA FIRST VICE-PRESIDENT JOHN E. MAULDING, P.E. BUILDING OFFICIAL LANCASTER, CALIFORNIA SECOND VICE-PRESIDENT DAVID A. BASSETT, P.E. BUILDING SAFETY DIRECTOR MEDFORD,OREGON IMMEDIATE PAST PRESIDENT H. T. "TED" WIEDENMAN, P.E. I DIRECTOR DEPARTMENT OF BUILDING DES MOINES, IOWA CHARLES CLAWSON DIRECTOR OF COMMUNITY DEVELOPMENT ARLINGTON, TEXAS SOL J. JACOBS, RE. DIRECTOR OF INSPECTIONS MINNEAPOLIS. MINNESOTA WILLIAM J. JUSTEN, P.E. DIRECTOR DEPARTMENT OF CONSTRUCTION AND LAND USE SEATTLE, WASHINGTON DONALD T. MacRAE, P.E. STATE BUILDING COMMISSIONER STATE OF INDIANA ADMINISTRATIVE BUILDING COUNCIL INDIANAPOLIS, INDIANA MICHAEL J. NOLTE SUPERINTENDENT OF BUILDING INSPECTION EUGENE.OREGON MARKR.ROOMAN DIRECTOR BUILDING SERVICES SPRINGFIELD, ILLINOIS WILLIAM E. SCHLECHT MANAGER, BUILDING. PLANNING AND ZONING DIVISION VANCOUVER, WASHINGTON DAVID R. SCOTT� P.E. DIRECTOR DEPARTMENT OF BUILDING SAFETY TEMPE, ARIZONA June 29, 1984 Harold Reeves Building, Official 250 5th Avenue N Edmonds, WA 98020 Dear Mr. Reeves: OFFICES OF JERRY J. BARBERA, P.E. REGIONAL MANAGER FRANK S. NATSUHARA, P.E. REGIONAL ENGINEER Plan Check 1422 Project: Flea Market Alteration Address: 24111 Highway 99 Edmonds, WA Type of Construction: V-N Occupancy Classification: B-2/A2-1 Stories: 2 Floor Area: 153,984 occupant Load: 3586 total; bingo rooms-- 384, 164, and 82 1979 Uniform Building Code Seismic Zone #3 I have reviewed the,"floor plan for exits and occupancy" for the Doces Mercantile Mall dated June 28, 1984 and have the following comments: 1. The large bingo room shou . Id be reduced to less than 4500 sf so that an A2.1 occupancy is not established. (An A2.1 occupancy will require 1 hour construction throughout in accordance with Table 5-C and also an 1 hour occupancy separation between it and the B-2 occupancy.) 2. An exit through an adjoining room is allowed but not through more than one room. The interior bingo rooms do not comply. Section 3302(e). Note that the 1982 UBC would permit only one of the exits to exit through an adjoining room, Exit passage- ways may be necessary to exit theinterior bingo rooms. Section 3303(e) p. 547 RONALD R. TREMBLAY CHIEF BUILDING AND ZONING INSPECTOR 3. The total required width of exits out of the bingo rooms SALINA,KANSAS should be 630/50 = 12.7' equally distributed between the 3 re- CHARLES W. VOLZ, A.I.A. The plans should be clarified to show conformity. CHIEF BUILDING OFFICIAL quired exits. DIVISION OF CODE ADMINISTRATION Section 3302(b) ALBUQUERQUE, NEW MEXICO STANLEY WHEELER xit doors that CHIEF BUILDING INSPECTOR 4. Panic hardware should be provided on all e LIVERMORE, CALIFORNIA serve the bingo rooms. Section 3315(d) EUGENE L ZELLER, P.E. SUPERINTENDENT. BUILDING AND SAFETY LONG BEACH. CALIFORNIA mia 90601 (213) 699-0541 EXECUTIVE DIRECTOR JAMES E. BIHIR, P.E. Main office: 5360 South Workman Mill Road Whittier, Califo 64 77 AL :% 1A Ae W, L WIN Ir en C 7e" 13 -t-7 A4 '5 Alls� c 'OF AL77 .17 Z7 "i. Its hr A 17/7 r - C'N 0 CITY OF EDMONDS 250 5th AVE. N. - EDMONDS, WASHINGTON 98020 - (206) 771-3202 BUILDING DIVISION June 19, 1984 G..John Doces Doce's Mercantile Nall 24111 Highway 99 Edmonds, WA 98020 Dear Mr. Doces: LARRY S. NAUGHTEN MAYOR The Edmonds Building Division is currently in receipt of a number of business license a ' pplications for tenants in your retail store at 24111 Highway 99. The following items must be completed to bring your property into compliance with City Codes so that business licenses may be issued: I. Please refer to letter from International Conference of Building Officials dated 4/28/84 (copy attached) for bringing the exiting from the building up to code. Note that item #3 requires lighted exit signs at all required exits. Further, the Fire Department requires emergency lighting to be provided that is adequate to illuminate all exit passageways. 2. Protection should be provided for all g.lazed openings.adjacent to and less than 18" above walking surfaces. Protection may be in the form of safety bars installed 30-34" above the floor, or tempered or laminated glass. 3. The electrical system must be upgraded by a licensed electrician. Adequate outlets must be provided to properly supply power to all use points. A State Electrical Permit is required. 4. A Building and Plumbing Permit is required for the second story kitchen and dining area. 5. An up-to-date floor plan of the existing layout should be provided to the Building Department. This plan must be kept current as tenants are added or rearranged. When items 1 - 5 are completed, please contact the Building Division for-- a re -inspection. G . John Doces June 19, 1984 Page Two 0 In addition to these items, arrangements must be made to complete the necessary improvements to the parking lot and exterior areas surrounding the building. Please contact the Planning Department regarding your inten- tions in this matter. If you have any questions regarding the Building and Fire Code requirements, please contact the Building Division. Harold Reeves Building Official attachment HR/cr cc: Mayor Naughten Planning Director L,F4<e Marshal City Attorney 0 3 0 1984 International Conference of Building Officials REGIONAL OFFICE: 17544 MIDVALE AVENUE N., SUITE 304 * SEATTLE, WASHINGTON 98133 (206) 542-9421 BOARD OF DIRECTORS OFFICES OF JERRV.LBARBEPkPX PRESIDENT REGIONAL MANAGER JACK S. ATKINII. P.E. FRANK 1IL NATSUHARA. RE. BUILDING OFFICIAL/ DEVELOPMENT SERVICES DIRECTOR April 27, 1984 AEGXXM EWNM PLACERVILLE. CALIFORNIA FIRST VICE-PRESIDENT Plan Check 1442 JOHN E. MAULMO. P.E. BUILDING OFFICIAL Project: Flea Market alteration LANCASTER. CALIFORNIA Address: 24111 Highway 99 SECOND VICE-PRESIDENT RL Edmonds, WA DAVID A. BASSETT. BUILDING SAFETY DIRECTOR Type of Construction:- V-N MEDFORD. OREGON Occupancy Classification: B-2 IMMEDIATE PAST PRESIDENT Stories: 2 m. T. -TEO" WIEDEHIAAK RL DIRECTOR Floor Area: 153,984 DEPARTMENT OF BUILDING DES MOINES, IONA Occupant Load: 3,389 1979 Uniform Building Code CHARLES CLAWSON Seismic Zone No. 3 DIRECTOR OF COMMUNITY DEVELOPMENT ARLINGTON, TEXAS SOL 4 JACOBS, P.E. Harold Reeves DIRECTOR OF INSPECTIONS MINNEAPOLIS, MINNESOTA Building Official WILLIAM.IJUSTEKRE. 250 5th Avenue N DIRECTOR Edmonds,,WA 98020 DEPARTMENT OF CONSTRUCTION AND LAND USE SEATTLE. WASHINGTON Dear Mr. Reeves: DONALD T. M&cAA1. P.E. STATE BUILDING COMMISSIONER STATE OF INDIANA ADMINISTRATIVE BUILDING COUNCIL Data and plans for the above project have been reviewed for INDIA,NAPOLIS. INDLV" conformance with the Uniform Building Code. They have not been MICMAELJ. NOM SUPERINTENDENT OF 8UILMG reviewed for compliance with requirements of federal, or other state and local INSPECTION EUGENE.OREGON regulatory agencies. Most of the following comments should be reflected as changes and notes on the plans MARK R. ROOMAN and in the specifications. DIRECTOR BUILDING SERVICES SPRINGFIELD. ILLINOIS GENERAL COMMENTS WILLIAM E. SCHLICHT MANAGER. BUILDING. PLANNING AND ZONING DIVISION VANCOUVER. WASHINGTON The exact use of "commercial recreation area" on the second floor DAVID It. SCOTT. P.E. DIRECTOR should be defined. An use other than "B" Occupancy should not be allowed in this building. Section DEPARTMENT OF BUILDING 506(b) SAFETY TEMPE, ARIZONA 2. The required exits should continue unobsfructed to the RONALD R. TREMBLAY CHIEF BUILDING -D exterior of the building, thence continue in an exit court to a public way: ZONING 14SPECTDR SALINA. KANSAS CHARLES W. VOLZ A.IJL a Exits should not discharge into a loading dock area. CHIEF BUILDING OFFICIAL DIVISION OF CODE ADMINISTAM)ON This would be considered an unacce tabl ALsUOLIERCUE. NEW MEXICO for exit purposes. Section 3302(e e adjol6ing area STANLEY WHEELER CHIEF BUILDING INSPECTOR LIVERMORE. CALIFORNIA b. The required exit width should be maintained, including EUGENE1 ZELLER P.E- the necessary stairways, down to grade. SUPERINTENDENT. BUILDNG Section 3302(c) AND SAFETY LONG BEACH. CALIFORNIA EXECUTIVE DIRECTOR JAMES 1. BIHR. P.E. Main Office: 5360 South Workman Mill Road 9 Whittier, . Califomia 90601 0 (213) 699-0541 Plan Check 1442 Harold Reeves, Edmonds April 27, 1984 Page Two c. Any elevated floor deck should be provide 'rai I s. Section 1716 d wi th guard d . Any parking adjacent to the building should be located so that the required width of exits will not be reduced. Parked cars should be considered as an obstruction to an exit way. 3. iProper exit signs and directional signs should be . provide&and should be illuminated in accordance with the provisions of Section 3312(a,c). 4. Any new openings in -the existing building as well as any new stairs sh . ould be detailed on the plans. 5. The required width of exits out of any area should be divided approxi- mately equal among the separate exits. Section 3302(b). It appears exit 15 should be increased to 61 width.' 6. Where 3 or more exits are required, they should be arranged a reasonable distance apart so that if one becomes blocked, the other will be available. The exit doors out of'area G & E do not appear to be reason'a'bly separated. 7. The required exit width out'of area G & E appe . ar-sl.ightly more than pro- vided. One half of the tributary occupant load from the storage areas H L should be included unless an independent exit from these areas tio to the ex- terio I r is provided in addi n to Exit 14. 8. Bo'oth partitions, if any, should not exceed 5'9" in height. Section 3304(a) An invoice for plan checking services rendered based on 4 hours will be for- warded to You under separate cover. I am returning all data and plans to you. If You wish me to do the recheck, Please instruct the architect to indicate on a separate sheet on which sheet or detail the corrections may be found and to return the check prints. I am taking the liberty of sending a copy of this list directl eir in lorder to facilitate the construction process. to the design - me if�there are any questions. Pleas�e feyel free to contact Very truly yours, 7 Frank S. Natsuhara, P.-E. Regional Engineer lih c/Paul Panagaris 0 0 June 18, 1984 MEMO TO: Hal Reeves, Building Official FROM.: Gary L. McComas Fire Marshal SUBJECT: LIFE SAFETY REQUIREMENTS FOR DOCE'S At the request of Mr. Doce we.have prepared a list of General Requirements for his building. 1. All exits must have illumination and signs. 2.-Emergency lighting must be provided that is adequate to illuminate all exit pathways. 3. The electrical system must be upgraded by a licensed electrician. Adequate outlets must be provided to properly supply power to all use points. GLM: be 41, 501-503 UNIFORM BUILDING CODE 1982 EDMON 503 Part III Table No. 5-C for such minor use, for the purpose of determining allowable area REQUIREMENTS BASED ON OCCUPANCY the major use of the building shall determine the occupancy classification. provided the uses are separated as specified in Section 503 (d). Except for buildings containing Group H. Division I through Division 4 Occupancies, the Chapter 5 provisions of this paragraph arc applicable to buildings constructed under the CLASSIFICATION OF ALL BUILDINGS provisions of Section 506 (b) for unlimited area. An occupancy shall not be located above the story or height set forth in Table BY USE OR OCCUPANCY AND GENERAL No. 5-D. except as provided in Section 507.-'--, REQUIREMENTS FOR ALL OCCUPANCIES I (b) Forms of Occupancy Separations. Occupancy separations shall be veni- cal or horizontal or both Occupancy Classified or, when necessary, of such other form as may be required to afford a complete separation between the various Sec. 501. Every building, whether existing or hereafter erected, shall be occupancy divisions in the building. classified by the building official, according to its use or the character of its occupancy, as a building of Group A. B. E. H. 1, M or R as defined in Chapters 6. Where the occupancy separation is horizontal. structural members supporting the separation shall be protected by equivalent fire -resistive construction. 7, 8, 9. 10. 11 and 12. (See Table No. 5-A -) Any occupancy not mentioned specifically or about which there is any question (c) T�pes of Occupancy Separations. Occupancy separations shall be classed as "four-hour fire "three-hour shall be classified by the building official and included in the group which its use most nearly resembles, based on the existing or proposed life and fire hazard. -resistive," fire -resistive." "two-hour fire-resis- tive," and "one -hour fire -resistive." (See U.B.C. Standard No. 43-7 for fire dampers in air ducts piercing occupancy separations.) Change in Use 1. A "four-hour fire -resistive occupancy separation" shall have no openings Sec. 502. Nochange shall be made in the characterof occupancies or use of any therein and shall be of no( less than four-bour fire -resistive construction. building which would place the building in a different division of the same group 2. A "three-hour fire-resistivc occupancy separation" shall be of not less than of occupancy or in a different group of occupancies, unless such building is made 1V three-hour firc-resistive construction. All openings in walls forming such separa- to comply with the requirements of this code for such division or group of tion shall be protected by a fire assembly having a three-hour fire -protection occupancy. rating. The total width of all openings in any threc-hour fire-resistivc occupancy EXCEPTION: The character of the occupancy of existing buildings may be separation wall in any one story shall not exceed 25 percent of the length of the changed subject to the approval of the building official, and the building may be occupied for purposes in other groups without conforming to all the requirements of this code for those the wall in that story and no single opening shall have an area greater than 120 square feet. groups, provided new or proposed use is less hazard4c based on life and fire risk, than the existing use. All openings in floors forming a "three-hour fire-resistivc occupancy p se ara tion" shall be protected by vertical enclosures No change in the charactcr of occupancy of a building shall be made without a extending above and below such openings. The walls of such vertical enclosures shall be of not less than two-hour Certificate of Occupancy, as required in Section 307 of this code. The building fire -resistive construction and all openings therein shall be protected by a fire official may issue a Certificate of Occupancy pursuant to the intent of the above assembly having a one and one -half-hour fire -protection rating. exception without certifying that the building complics with all provisions of this code. 3. A "two-hour fire -resistive occupancy separation" shall be of not less than Mixed Occupancy— 0 A*'^.% W-73 X:A—./ two-hour fire -resistive construction. All openings in such separafion shall be protected by a fire assembly having a one and onc-half-hour fire -protection rating. - Sec. 503. (a) General. When a building is used for more than one occupancy 4. A "one -hour fire-resittive occupancy separation" shall be of not less thgn purpose, each part of the building comprising a distinct "Occupancy," as one -hour rLm-msistive construction. All openings in such separation shall lb� described in Chapters 5 through 12, shall be separated from any other occupancy protected by a rim assembly having a one -hour fire -protection rafing. as specified in Section 503 (d). When a building houses more than one occupancy, each portion of the building (d) Fin Ratings fo�Occupancy Separations. Occupancy separations shall be provided between the various groups and divisions shall conform to the requirements for the occupancy housed therein. T11e ama of the building shall be such that the of occupancies as set forth in Table No. 5-B. sum of the ratiosof the actual areadivided by the allowable area for such separate occupancy shall not exceed one. EXCEPTIONS: 1. Where an approved spray booth constructed in accordance =D Where minor accessory uses do not occupy mom than 10 percent of the area of with the Fire Code is installed, such booth need not be separated from other Group H Occupancies or from Group B Occupancies. any floor of a building, nor more than the basic area permitted in the occupancy by 2. In Groups A, Division 1. E and I Occupancies a dime -hour occupancy so 1716 UNIFORM BUILDING CODE 1982 EDITION 1715-1716 3. In industry facilities. mezzanines used for control equipment may be glazed on separation which is adjacent to the atrium may be omitted between a Group B. all skies. Division 2 Occupancy office or sales area or Group A. Division 3 Occupancy and 5. 7Wo exits shall be provided from mezzanines having an occupant load of Group R. Division I apartment or guest room located on another level. more than 10 or when the area of the mezzanine exceeds 2000 square feet, (g) Standby Power. The smoke -control system for the atrium and the smoke- whichever is the more restrictive. 'Me control system for the tenant space are to be provided with standby power as 6. occupant load of the mezzanine shall be added to the occupant load of required in Section 1807 (i). the story or room in which it is located. (h) Interior Finish. The interior finish of walls and ceilings of the aLri an um d ll u a nsepamted tenant spaces allowed under the last paragraph of Subsection (c) above shall be Class I with no reduction in class for sprinkler protection. (i) Acceptance of the Smoke-contml System. Before the Certificate of Occupancy is ossued. the smokc­i:bntrol systems shall be tested in an approved inanner and shall show compliance with the requirements of this section. Inspection of the Smoke -control System. All operitting parts of the srnoke-control systems shall be tested by an approved inspection agency or by the owner or his representative when so approved. Such inspections shall be made eve ry three months and a log of the tests be kept by the testing agency. Tbe log AIM shall be on the prcmiscs and available for examination by fire department personnel. (k) CombusUble Furnishings In Atriums. 77he quantity of combustible fur- nishings in atriums shall not exceed that specified in the Fire Code. Me— nines Sec. 1716. Rooms may contain mezzanine floors when constructed in accor- dance with the following: 1. The construction of a mezzanine shall be consistent with the requirements for the type of construction in which the niczzaninc is located. but the fue- resistive time period need not exceed one hour for unenclosed me ties constructed in accordance with Item No. 4 below. The clear height above and below the me77anine floor construction shall be not less than 7 fect. 2. Tbcre shall be not more than two levels of mezzanines in a room. Howem them is no limitation on the number of mezzanines within a room. 3. 71w aggregate area of mezzanines within a room shall not exceed one third the area of the room in which it is located. Intermediate floor levels do at 6 or more feet above grade shall be considered a story when the am of such le-rel exceeds one third the area of the room in which it is located. 4. Ali portions of a mezzanine shall be open to the moto in which it is located. The side of the mezzanine *hich is open to thetoo shallbetmobstiactedex for columns and posts and wall$ or rallinp 42 Inch A -12' protective not mom than a height.. EXCEPrIM: 1. Partitioning may be installed, piovided do SS I e ftor 11A, am of the does oot ex 10 percent of die an of dw mezzaafte or anoccupent load nmcxcecdinS 10. whicbeverisl i 2. Mezzanines having twoormoreexits need am open intothestay In hirl dicy are Imated peov 01 least one of the caits gnu direct accen to a proacted exit rm 'Im an =it court. enclosed exit swifway, exterior exit. exitbalconyor exit Passageway Q� 105 108 J law. TABLE NO. 5-D—MAXIMUM HEIGHT OF BUILDINGS TYPES OF CONSTRUCTION OCCUPANCY I III IV F.R. F.R. ONE -HOUR N 11ONE-HOUR I N H.T. ONE -HOUR ji-!2FN MAXIMUM HEIGHT IN FEET Unlimited 160 65 55 1 65 1 55 65 50 40 MAXIMUM HEIGHT IN STORIES A-1 Unlimited 4 Not Permitted A) 2-2.1 Unlimited 4 2 Not Permitted 2 Not Permitted 2 2 Not Permitt Unlimited 12 2 1 2 1 2 2 fv"�I B) 1-2-31 Unlimited 12 4 2 4 2 4 3 2 B-4 Unlimited 12 4 2 4 2 4 3 2 E2 Unlimited 4 22 1 I 22 1 1 1 22 1 22 1 H-1 Unlimited 2 1 1 1 1 1 1 1 H) 2-3-4-5 Unlimited 5 2 1 2 1 2 2 1 1-1 Unlimited 3 1 I Not Permitted I Not Permitted I I Not Permitted 1-2 Unlimited 3 2 1 Not Permitted 2 Not Permitted 2 2 - Not Permitted 1-3 Unlimited 2 Not Permitted 3 W hSinfer --- — ----- R-I Unlimited 12 4 25 1 4 23 4 23 R-3 Unlimited 3 3 3 3 1 3 3 3 C z 'For open parking garages. see Section 709. 2Sce Section 802 (c). '*—No requirements for fire resistance 0 3Sce Section 1002 (b) ER. —Fire resistive 4For agricultural buildings, see also Appendix Chapter 11. H.T.—Heavy Timber 3For limit�41ions and exceptions, we Section 1202 (b). zi %: N! V fz -PON i. CITY OF EDMONDS LARRY S. NAUGHTEN 250 5th AVE. N. - EDMONDS, WASHINGTON 98020 - (206) 771-3202 MAYOR BUILDING DIVISION June 12, 1984 Paul Panagakis and Co. 341 Skinner. Building Seattle, WA 98101 Dear Mr. Panagakis: As the attached UBC sections indicate your proposal to locate an A-3 Assembly Occupancy in the second level of the Doces building is not in conformance with the Code. The alternatives are to: 1. Perform the necessary remodeling to qualify the upper level as a mezzanine per UBC Section 1716. 2. Perform the necessary remodeling to qualify the building as V - 1 hour construction. 3. Locate the assembly area on the fi.rst floor. Detailed plans including interior elevations should be submitted to indicate the scope of the work. Harold Reeves Building Official HR/cr cc: Doces Mercantile Mall 6 0 E 4A k\ 40� .N. ...-APR 3 0 1984 International Conference of Building Officials REGIONAL OFFICE: 17544 MIDVALE AVENUE N., SUITE 304 - SEATTLE, WASHINGTON 98133 (206) 542-9421 PRESIDENT JACK S. ATKINS, P.E. BUILDING OFFICIALY DEVELOPMENT SERVICES DIRECTOR PLACERVILLE. CALIFORNIA FIRST VICE-PRESIDENT JOHN E. MAULDING, P.E. BUILDING OFFICIAL LANCASTER, CALIFORNIA SECOND VICE-PRESIDENT DAVID A. BASSETT� P.E. BUILDING SAFETY DIRECTOR MEDFORD, OREGON IMMEDIATE PAST PRESIDENT H. T. 44TED" WIEDENMAN, P.E. DIRECTOR DEPARTMENT OF BUILDING DES MOINES, IOWA CHARLES CLAWSON DIRECTOR OF COMMUNITY DEVELOPMENT ARLINGTON, TEXAS SOL J. JACOBS P.E. DIRECTOR OF INSPiCTIONS MINNEAPOLIS. MINNESOTA WILLIAM 4 JUSTEN, P.E. DIRECTOR DEPARTMENT OF CONSTRUCTION AND LAND USE SEATTLE, WASHINGTON DONALD T. MacRAE, P.E. STATE BUILDING COMMISSIONER STATE OF INDIANA ADMINISTRATIVE BUILDING COUNCIL INDIANAPOLIS, INDIANA MICHAEL J. NOLTE SUPERINTENDENT OF BUILDING INSPECTION EUGENE,OREGON MARK R. RODMAN 0 RECTOR IF BUILDING SERVICES SPRINGFIELD, ILLINOIS WILLIAM E. SCHLECHT MANAGER, BUILDING, PLANNING AND ZONING DIVISION VANCOUVER, WASHINGTON DAVID R. SCOTT, P.E. DIRECTOR DEPARTMENT OF BUILDING SAFETY TEMPE, ARIZONA RONALD R. TREMBLAY CHIEF BUILDING AND ZONING INSPECTOR SALINA, KANSAS CHARLES W. VOLZ, A.I.A. CHIEF BUILDING OFFICIAL DIVISION OF CODE ADMINISTRATION ALBUQUERQUE, NEW MEXICO STANLEY WHEELER CHIEF BUILDING INSPECTOR LIVERMORE, CALIFORNIA EUGENE J. ZELLER, P.E. SUPERINTENDENT, BUILDING AND SAFETY LONG BEACH, CALIFORNIA EXECUTIVE DIRECTOR JAMES E. BIHR, P.E. April 27, 1984 Plan Check 1442 Project: Flea Market alteration Address: 24111 Highway 99 Edmonds, WA Type of Construction: V-N Occupancy Classification: B-2 Stories: 2 Floor Area: 153,984 Occupant Load: 3,389 1979 Uniform Building Code Seismic Zone No. 3 Harold Reeves Building Official 250 5th Avenue N Edmonds, WA 98020 Dear Mr. Reeves: OFFICES OF JERRYJ. BARBERA, P.E. REGIONAL MANAGER FRANK S. NATSUHARA, P.E. REGIONAL ENGINEER Data and plans for the above project have,been reviewed for conformance with the Uniform -Building Code. They have not been reviewed for compliance with requirements of federal, or other state and local -regulatory agencies. Most of the following comments should be reflected as changes and notes on the plans and in the specifications. GENERAL COMMENTS 1. The exact use of "Commercial recreation area" on the second floor should be defined. An use other than "B" occupancy should not be allowed in this building. Section 506(b) 2. The required exits should continue unobs�ructed to the exterior of the building, thence continue in an exit court to a public way: a. Exits should not discharge into a loading dock area. This would be considered an unacceptabl.e adjoining area for exit purposes. Section 3302(e) b. The required exit width should be maintained, including the necessary stairways, down to grade. Section 3302(c) Main Office: 5360 South Workman Mill Road - Whittier, California 90601 e (213) 699-0541 Plan Check 1442 Harold Reeves, Edmonds April 27, 1984 Page Two c. Any elevated floor deck should be provided with guard rails. Section 1716 d. Any parking adjacent to the building should be located so that the� required width of exits will not be reduced. Parked cars should be considered as an obstruction to an exit way. 3. Proper exit signs and directional signs should be provided and should be illuminated in accordance with the provisions of Section 3312(a,c). 4. Any new openings in the existing building as well as any new stairs should be detailed on the plans. 5. The required width of exits out of any area should be divided approxi- mately equal among the separate exits. Se C tion 3302(b). It appears exit 15 should be increased to 6' width. 6. Where 3 or more exits are required, they should be arranged a reasonable distance apart so that if one becomes blocked, the other will be available. The exit doors out of area G & E do not appear to be reasonably separated. 7. The required exit width out of area G & E appear slightly more than pro- vided. One half of the tributary occupant load from the storage areas H & L should be included unless an independent exit from'these areas to the ex- terior is provided in addition to Exit 14. 8- Booth partitions, if any, should not exceed 5'9" in height. Section 3304(a) An invoice for plan checking services rendered based on 4 hours will be for- warded to you under separate cover. I am returning all data and plans to you. If you wish me to do the recheck, Please instruct the architect to indicate on a separate sheet on which sheet or detail the Corrections may be found and to return the check prints. I am taking the liberty of sending a copy of this list directly to*the design- er in order to facilitate the construction process. Pleas,e feel free to contact me if there are any questions. Very truly yours, Frank S. Natsuhara, P.-E. Regional Engineer lih C/Paul Panagaris FEB 2 2 1984 International Conference of Building Officials REGIONAL OFFICE: 17544 MIDVALE AVENUE N., SUITE 304 9 SEATTLE, WASHINGTON 98133 (206) 542-9421 BOARD OF DIRECTORS OFFICES OF JERRY J. BARBERA. P.E. PRESIDENT REGIONAL MANAGER JACKS. ATKINS, P.E. FRANK S. kATSUIHARA. P.L BUILDING OFFICIAL/ February 16*, 1984 REGIONAL ENGINEER DEVELOPMENT SERVICES DIRECTOR PLACERVILLE. CALIFORNIA FIRST VICE-PRESIDENT RECEIVED JOHN E. MAULDING, P.E. BUILDING OFF:CIAL LANCASTER. CAL FORNIA Hal Reeves FEB 2 7 1984 SECOND VICE-PRESIDENT Building Official DAVID A. BASSETT� P.E. 250 - 5th Ave N EDMONDS FIRE DEPT. BUILDING SAFETY DIRECTOR MEDFORD, OREGON Edmonds, WA 98020 IMMEDIATE PAST PRESIDENT H. T. "TED" WIEDENMAN, P.E. SUBJECT: EXITS OUT OF DOCES MERCANTILE BASED ON 1979 UBC DIRECTOR DEPARTMENT OF BUILDING DES MOINES, IOWA Dear Hal: CHARLES CLAWSON DIRECTOR OF COMMUNITY After reviewing the plan of the Doces mercantile building DEVELOPMENT ARLINGTON, TEXAS you sent me dated February 14, 1984 1 have the following comments; SOL J. JACOBS, P.E. DIRECTOR OF INSPECTIONS MINNEAPOLIS, MINNESOTA 1. The building was assumed to be fully sprinklered, retail WILLIAM J. JUSTEN, P.E. DIRECTOR sales use, and of Type V construction. DEPARTMENT OF CONSTRUCTION AND LAND USE SEATTLE, WASHINGTON 2. am returning the plan to you. However, I have marked DONALD T. MacRAE, P.E. the areas with the letters A through H for ease of identifi- STATE BUILDING COMMISSIONER STATE OF INDIANA cation and my following comments will refer to these marks. I ADMINISTRATIVE BUILDING COUNCIL INDIANAPOLIS. INDIANA I have designated the following occupant loads for these fol- lowing areas: MICHAEL J. NOLTE SUPERINTENDENT OF BUILDING INSPECTION EUGENE,OREGON A = Main room = 1,464 occupants MARK R. RODMAN B = Smaller room at North end = 159 IF D RECTOR BUILDING SERVICES SPRINGFIELD, ILLINOIS C = Center room = 400 WILLIAM E. SCHLECHT MANAGER, BUILDING, PLANNING D = Smaller room at South end = 152 AND ZONING DIVISION VANCOUVER, WASHINGTON E = Large room to the east of area C 800 DAVID R. SCOTT� P.E. DIRECTOR F = Warehouse = 64 DEPARTMENT OF BUILDING SAFETY G = Second floor = 564 TEMPE, ARIZONA RONALD R. TREMBLAY H = Storage mezzannine = 27 CHIEF BUILDING AND ZONING INSPECTOR SALINA, KANSAS 3. Aisles must be maintained unobstructed leading to exits. CHARLES W. VOLZ A.I.A. CHIEF BUILDING OFFICIAL Section 2213(a). Note: The 1982 UBC, Section 3315(b), requires DIVISION OF CODE ADMINISTRATION minimum clear unobstructed aisle to be 36" where tables, coun- ALBUQUEROUE. NEW MEXICO ters, furnishings, merchandise or other obstructions STANLEY WHEELER CHIEF BUILDING INSPECTOR -similar are placed on one side of the aisle only and 44" when such obstruc- tions LIVERMORE, CALIFORNIA are placed on both sides of the aisle. The cross aisle or aisles leading to EUGENE J. ZELLER, RE. SUPERINTENDENT, BUILDING exits should be at least as wide as the tribu- tary occupant AND SAFETY load to that exit di�ided by 50. LONG BEACH, CALIFORNIA EXECUTIVE DIRECTOR JAMES E. BIHR, P.E. Main Office: 5360 South workman Mill Road * Whittier, California 90601 11 (213) 699-0541 Hal Reeves February 16, 1984 Page Two 4. Exit illumination and exit sign illumination should comply with the provisions of Section 3312. Separate circuits and separate sources of power should be required. Sufficient exit signs and directional signs should be provided to clearly indicate the direction of egress. Section 3311(b) 5. Area "B" should be provided with a second means of egress separated by a minimum of 112 of the longest diagonal dimension. Section 3302(c) 6. Area "D" should be provided with 2 adequately separa-te means of egress. It may exit into Room C but Room C does not exit directly to the exterior. This is unsatisfactory unless an exit passageway is developed for Exit 5. Section 3302(e) I 7. Area C may exit through any of the adjoining rooms A, E, 0, or B. How- ever, its tributary occupant load must be added to the occupant load of that room for the determination of required number and width of exits out of that.room. 8. 1 have, assumed the following distribution of Area C occupant load: To Area A = 400 + 27 = 107 4 To Area B = 11 11 - To Area 0 = 11 11 To Area E = 11 11 Note: The 1982 UBC will allow only one of its required exits to exit through an adjoining room. Section 3303(e) 1982 UBC a. Based on the assumption that 107 occupants discharge into Room A from Room C, the following total occupant load is tributary to Room A: 1464 + 107 + 152/2 = 564/2 = 1929. Therefore, 4 exits reasonably separated is required and 38.58' width of exits approximately equally distributed should be proXided for Room A. b. Based on 107 occupants from Room C the occupant load tributary to Room E is 107 + 800 = 907 occupants. Therefore, the required number of exits is equal to 3 that are reasonably separated and the required width of exits = 18-14'. 9. Mezzannine storage should have 2 means of egress. The stair which serve the storage mezzannine should discharge to rooms which have exits directly to the exterior; not to,adjoining rooms. Section 3302(e) 10. Double acting doors do not comply. Section 3303(g) Hal Reeves February 16, 1984 Page Three 11. The foregoing comments were based on a small scale plan with few di- mensions and therefore the occupant loads are approximate. If you wish, we will gladly review a'more complete set of plans under.our formal plans examination program. Please feel free to contact me if you have any questions. Very truly yours, Frank S. Natsuhara, P.E. Regional Engineer lih 0 0 0 February 21, 1984 MEMO TO: Hal Reeves Building Official FROM: Gary L. McComas Fire Marshal SUBJECT: DOCE'S, COMMERCIAL ALTERATIONS AT 24111 HIGHWAY 99 After review, the fire.department has the following require- ments: 1. Emergency lighting facilities shall be arranged to maintain the specified degree of illumination throughout the means of egress, but not less than 1 footcandle for a period of lk hours in the event of failure of the normal lighting. This system shall be designed by an architect or lighting engineer. 2. Provide electrical d istribution so that the use of electrical cords will be eliminiated. I GLM: b e 1. 6 0 MEMO TO: Mary Lou Block Director of Planning FROM: Gary L. McComas Fire Marshal February 15, 1984 p V �Mj) 4 1984 Cjn SUBJECT: REVIEW OF PARKING LOT LAYOUT AT DOCES. 24111 HIGHWAY 99 After review, the fire department has the following comments: 1. The fire lane must be designated by marking on the asphalt surface and signing. This must include the entire perimeter of the building. 2. The fire -hydrant in the southeast.corner of the existing parking area must be relocated in the planter area. 3. Parking must be restricted in the area of the north hydrant. 4. Indicate plans for pxtending parking area to western extension indicated by -proposed edge of parking. 5. Proposed parking in loading dock area must be in- dicated on future plans. Any parking in this area must maintain the established fire lane. 4A C_0b"k4L4_ GLM: be 110, 0 0 JAMES A. MURPHY— JOHN D. WALLACE DOUGLAS E. ALBRIGHT LEE CORKRUM; WAYNE D. TANAKA G- GEOFFREY GIBBS* LARRY C. MARTIN OF COVNSEL RAYMOND 0. OGDEN. JR. RONALD A. MURPHY** RAYMOND D. OGDEN (1876-1972) Mr. G. John Doces LAW OFFICES OF. OGDEN, OGDEN & MURPHY 2300 WESTIN BUILDING 2001 SIXTH AVENUE SEATTLE, WASHINGTON 98121 (206) 622-2991 Doces Enterprises, Inc. 4432 55th Avenue N.E. Seattle, WA 98105 Dear Mr. Doces: January 13, 1984 Re: Zoning Violations MARK A. EAMES R. MARK ALLEN STEVEN A. REISLER LAURA C. INVEEN CHRISTOPHER A. WASHINGTON- ROBERT G. ANDRtt MICHAEL G. WICKSTEAD JAMES E. HANEY —0 AOM-� IN ­­ A� ADM�D IN CAUFOM. -1.50 AD —III) IN OW.ICT 01 C01.11. t ­0 --= IN COLO-O...— 101t. A.o E. AM, —0 ADM—ED IN --- This firm represents the City of Edmonds and serves as its City Attorney. The building and planning department of the City of Edmonds has referred to my attention a certain situation involving property owned by your corporation, Doces Enterprises, Inc. The property in question is located on Highway 99 at its intersection with 240th Street S.W. After an investigation conducted by the City staff, several violations of the City's Community Development Code have been discovered on your property. These violations relate to the construction of a parking lot located just east of the easternmost warehouse building on the property. This parking lot was constructed recently and without the prior review or approval by the City of Edmonds. By construction of this parking lot your corporation has permitted the following violations of the Community Development Code: 1. Failure to obtain a Parking Lot Construction Permit: This is a requirement of Section 18.95.000 and requires the approval of both the City's Architectural Design Board and the City's Public Works Director. If this is merely a temporary parking lot you are still required to get the approval of the City's Architectural.Design Board, Section 17.50.090. 2. Failure to Obtain a Grading Permit: Section 18.40.000 requires that you apply for and obtain a grading permit prior to any filling on,your property as has already occurred. 0 0 Mr. G. John Doces January 13, 1984 Page 2 3. No Commercial Parking.Permitted in an RM Zone: This parking lot is located on property which is zoned for multiple family residential. Section 16.30.010(B) of the Community Development Code only allows private parking in such a zone. Section 21.80.080 defines the term 11private" as referring to noncommercial uses only. In December cars were parked in this parking lot in connec- tion with the retail business conducted on your property. Violations of the Community Development Code are mis- demeanors and are subject to fines of up to $500.00 for every day that each violation continues and, if appropriate, a jail penalty of up to 90 days in jail. Certainly the City does not wish to take such legal action against your corporation and/or the individuals involved and would prefer that these zoning violations be remedied without such legal action. In order to come into compliance with the City Code the present parking lot must be removed and the property returned to its original grade. This applies to all portions of that parking lot which are located in the multiple family residen- tial zone. Apparently there was a chain link fence running north/south approximately 20 feet from the east wall of your warehouse. The fence posts still remain. This fence line marks the approximate boundary of the multi -family residential zoning which lies to the east of that fence line. Therefore the parking lot to the east of that fence line must be removed. No cars may be parked in the multi -family residen- tial zone. Before any parking lot can be constructed else- where on your property you must apply for a parking lot construction permit and, if any grading is required, a grading permit. If you have any further questions regarding the steps that need to be taken to come into compliance with the City's code please feel free to contact me or Duane Bowman of the Planning Department or Hal Reeves, the City's Building Official. I can be reached at the number listed in this letterhead, and the City staff can be reached at 771-3202. I trust that this matter will go no further. If these violations are not corrected within ten days of the date of this letter, however, this office is authorized to take whatever enforcement action is necessary to insure your com- pliance. By copy of this letter I am directing Mr. Bowman and/or Mr. Reeves to advise me of your compliance with the terms of the Edmonds Community Development Code. If you have 4 0 0 Mr. G. John Doces January 13, 1984 Page 3 any questions regarding this matter please feel free to contact me. Very truly yours, OGDEN, OGDEN & MURPHY Mark A. Eames MAE:jt cc: Mayor Naughten Members of the City Council Duane Bowman Hal Reeves Dean Doces Sam Doces Bill Appel -1 /,;L -.30 - 3 'r rR- IF 44 0 9,,�e-7�5 7 o-w-er-5 u -4 /6- H TS r,>ts��e) c"i 1 0 7-0 6L-�E 7-11251<- P1, J C C- 0 /fj 0 7- a 7-0 1/-'-/ 4Jc-�- 7-IOX-.,' ou 7-,7 0 0 TO fik-,46-6— 4 / e��U IOU C) I— - V- 1 4 — 0 0— / 9 Z � �, ��' 5/75/ ZE Z-?�Z 02 oe 7--A 0 ,— U-2 ---r C, —,K4C--/2L5� 4� Q, J3 —,Oo /ILI '5 7Z)A 't CITY OF EDMONDS CIVIC CENTER * EDMONDS, WASHINGTON 98020 - (206) 775-2525 FIRE DEPARTIMENt December 28, 1983 CERTIFIED MAIL P056257995 Mr. Dean Doce 4432-55th N. E. Seattle, WA 98105 Dear Mr. Doce, SUBJECT: EDMONDS PUBLIC FLEA MARKET HARVE H. HARRISON MAYOR The following is a list of fire code requirements that shall be completed and maintained. All listed items shall be completed within 15 days from date of this letter unless time extensions of completion on specific items are granted by the fire depart- ment. 1. Smokina No smoking signs shall be posted and enforced through- out the building except for the following areas: a. Food concessions b. Office areas UFC - Sec. 29.101 2. Fire lanes 20 feet of unobstructed width shall be maintained around the entire building with adequate roadway turn- ing radius so as not to restrict fire equipment. See Figure 18­2 for auide lines. UFIC - Sec. 13.208 0 3. Sprinkler systems, fire hydrants and portable fire extinguishers All equipment and systems shall be maintained in an operative condition at all times and shall be replaced or repaired where defective. Fire -protective or ex- tinguishing systems coverage, spacing and specifica- tions shall be maintained in accordance with recognized standards at all times and shall be extended, altered or augmented as necessary to maintain and continue pro- tection whenever any building so equipped is altered, remodeled or added to. UFC - Sec. 13.301-13.302 Mr. Dean Doce December 28, 1983 Page 2 4. Maintenance of exit waxs a. Obstruction: No obstruction or storage shall be placed in the required width of an exit. 7JFC - Sec. 10.103 b. Doors: Exit doors shall be openable from the inside without the use of a key or any special knowledge. UFC - Sec. 10.104(b) c. 'Door identification: Exit doors shall be so marked that they are readily distinguishable from adjacent construction. UFC - Sec. 10.104(d) d. Exit signs: At every required exit doorway and wherever otherwise required to clearly indicate the direction of egress. UFC - Sec. 10.113(b) e. Illimination of signs: Exit signs shall be lighted and maintained with two electric lamps of not less than 15 watts each. Separate circuits, one of which shall be separated from all other circuits in the building and independently controlled, shall be maintained. UFC - Sec. 10.113(a). 5. Obstruction of fire -protection equipment No person shall place any vehicle, trash, storage or other material or thing near any fire hydrant, fire deDartment connection or fire protection system control valve that would prevent such equipment or hydrant from being immedi- ately discernible or in any manner deter or hinder the fire department from gaining immediate access to said equipment or hydrant. UFC - Sec. 13.206 If we may be of any assistance, please contact this office by call- ing 775-2525 between the hours of 8 a.m. and 5 p.m., Monday through Friday. Since ly, Ron Schirman Acting Fire Chief RS: be cc: Wayne Tanaka City Attorney TURNING CLEARANCES FOR ACCESS OF FIRE FIGHTING EQUIPMENT NOTE: MINIMUM VERTICAL qLEARANCE WITHIN ROADWAY WIDTH SHALL BE 1136� 41 -no-STANDARD CLEARANCES TO BE USED UNLESS OTHERWISE RE- OUIRED OR PERNTTED BY THE FIRE MARSHALL. MINIMUM ROADWAY FOR TWO-WAY TR SEE FIG. 16.1 FOR ONE -WAY TRAFFIC AISLE WIDTH. NO AISLE WIDTH SHALL BE LESS THAN 11.5 FEET WHEN REQUIRED FOR FIRE ACCESS. -or--CLEARANCES TO BE USED WHEN REQUIRED BY THE FIRE MAR - SHALL FOR SNORKEL TRUCK ACCESS. FOR TWO-WAY TRAFFIC SEE FIG. 18.1 FOR ONE-WAY TRAFFIC AISLE WIDTH. NO AISLE WIDTH SHALL BE LESS THI 12.0 FEET WHEN REQUIRED FOR SNORKEL TRUCK ACCESS. --*-CLEARANCE MAY BE USED ONLY WHEN PERMITTED BY THE FIRE MARSHALL. _`,,-�Ml�NIMUM ROADWAY WIDTH a; FOR TWO-WAY TRAFFIC SEE FIG.- 18.1 FOR ONE-WAY TRAFFIC AISLE WIDTH. NO AISLE WIDTH SHALL BE LESS T 11.0 FEET WHEN REQUIRED FOR FIRE ACCESS FIG. 18-2 156 ,a E 0 CITY OF EDMONDS CIVIC CENTER - EDMONDS. WASHINGTON 98020 * (206) 775-2525 FIRE DEPARTMENT Mr. G. John Doce:; 24111 Highway 99 Edmonds, WA 98020 Dear Mr. Doce December 12, 1983 CERTIFIED MAIL: P056257675 SUBJECT: EDMONDS PUBLIC FLEA MARKET HARVE H. HARRISON MAYOR The following is a list of fire code requirements that shall be completed and maintained. All listed items shall be completed within 15 days after receipt of this letter unless time exten- sions of completion on specific items are granted by the fire department. 1. Smoking .No smoking signs shall be posted and enforced through- out the building except for the following areas: a. Food concessions b. Office areas 2. Fire lanes 20 fee unobstructed width shall be maintained around the entire building with adequate roadway turn- ing radius so as not to restrict fire equipment. See Figure 18-2 for guide lines. 3. Sprinkler systems, fire hydrants and portable fire extinguishers All equipment and systems shall be maintained in an operative condition at all times and shall be replaced or repaired where defective. Fire -protective or ex- tinguishing systems coverage, spacing and specifica- tions shall be maintained in accordance with recognized standards at all times and shall be extended, altered or augmented as necessary to maintain and continue pro- tection whenever any building so equipped is altered, remodeled or added to. Mr. G John Doce December 12, 1983 Page #2 4. Maintenance of exit ways Obstruction: No obstruction or storage shall be placed in the required width of an exit. Doors:.Exit doors shall be openable from the inside without the use of a key or any Special knowledge. Door identification: Exit doors shall be so marked that they are readily distinguishable from adjacent construction. Exit signs: At every required exit doorway and wherever otherwise required to clearly indicate the direction of egress. Illumination of signs: Exit signs shall be lighted and maintained with two electric lamps of not less than 15 watts each. Separate circuits, one of which shall be separated from all other circuits in the building and independently controlled, shall be maintained. 5. Obstruction of fire -protection equipment No person shall place any vehicle, trasS, storage or other material or thing near any fire hydrant, fire department connection or fire protection system control valve that would prevent such equipment or hydrant from being immediately discernible or in any manner deter or hinder the fire department from gaining immediate access to said equipment or hydrant. If we may be of any assistance, please contact this office by calling 775-2525 between the hours of 8 a.m. and 5 p.m., Monday through Friday. Sincerely, L. McComas Fire Marshal GL14: be 10.95.020 TURNING CLEARANCES FOR ACCESS OF FIRE FIGHTING EQUIPMENT NOTE: MINIMUM VERTICAL &�EARANCE WITHIN ROADWAY WIDTH SHALL BE 4f --a-STANDARD CLEARANCES TO BE USED UNLESS OTHERWISE RE- QUIRED OR PERMITTED BY THE FIRE MARSHALL. MINIMUM ROADWAY WIDTH FOR TWO-WAY TRAFFIC SEE FIG. 18.1 FOR ONE-WAY TRAFFIC AISLE WIDTH. NO AISLE WIDTH SHALL BE LESS THAN 11.5 FEET WHEN REQUIRED FOR FIRE ACCESS. -46-CLEARANCES TO BE USED WHEN REQUIRED BY THE FIRE MAR - SHALL FOR SNORKEL TRUCK ACCESS. FOR TWO-WAY TRAFFIC SEE FIG. 18.1 FOR ONE-WAY TRAFFIC AISLE WIDTH. NO AISLE WIDTH SHALL BE LESS THAN L-,�YI12.0 FEET WHEN REQUIRED FOR SNORKEL TRUCK ACCESS. --*-CLEARANCE MAY BE USED ONLY WHEN PERMITTED BY THE FIRE MARSHALL. MINIMUM ROADWAY WIDTH FOR TWO-WAY TRAFFIC SEE FIG; 18.1 FOR ONE-WAY TRAFFIC AISLE WIDTH. NO AISLE WIDTH SHALL BE LESS THAN 11.0 FEET WHEN REQUIRED FOR FIRE ACCESS. - FIG. 18-2 156 Ll 0 DOCES INC 24111 HWY 99 � SCALE I "t = 60 f -- N 10 ACING LOADM CK DOCK E) ?F E -4- CPO . 9t 14 7 1 1 61- CD -f Ao fi 7: 7 7. 10, MN FLMR M - 0 2 CITY OF EDMON113S HARVE H. HARRISON MAYOR CIVIC CENTER - EDMONDS, WASHINGTON 98020 - (206) 775-2525 I BUILDING DEPARTMENT November 18, 1983 Dean Doces 24111 Highway 99 Edmonds, WA 98020 CHANGE OF CHARACTER OF OCCUPANCY @ 24111 HIGHWAY 99 A joint inspection on November 15, 1983 by the City's Building and Fire Departments revealed a number of.items which must be completed so that the building will be in compliance with building �nd fire codes for a change in character of occupancy. 1. Provide exit lighting, signage and clearly marked route of travel for all exits. ' 2. Provide handrail for ramp leading to East floor area. 3. Repair stair handrail on South exterior stair. 4. Obtain an electrical permit and inspection by the Department of Labor and Industries. 5. Service all fire�extinguishers in the building. Please contact the Building Department when the above items are completed. Harold Reeves, Building Official 9 0 C1 Y of EDMON APPLICATION DATE LICENSE NO. Edmonds J*-- Civic Center Qty Gipr I-lione TYPE OF BUSINESS ANNUALFEE AFTER FEB. 15 IM . 9 4EASG LIC. NO. SPEC. (A) HOME OCCUPATION $15.00 $ 22.50 I N ST R U -'-'T 10 N S: (B) BUSINESS WI rH $20.00 $ 30.00 a Ali iterns must be cwnok A� PRINTX 1 TO 3 EMPLOYEES Ej BUSINESSwirH $22.00 $ 33.00 or''application will not r �.IN SPEC. 13OX (C) FOR ISSUE OF TO 9 EMPLOYEES EE PAID PEN T'Y-PAID I �,;ign and return apphcatif% 1 CORRECTED LICENSE WITH BUSINESS WITH 10 $75.00 OR MORE EMPLOYEES $112.50 /1,0: 0, LC- ACTION. with fee. Renewals re Ceiv�,-j Ae. d 0 NEWAPPLICATION (LA) after February 15 must p3y C). penalty in addilinn tn Iwo. El RENEWAL (LB) NEW BUSINESSES AFTER 0 CHANGE (I-C) JULY 131, -l12 FEE. (PLEASLE l`Jl*-'--,ESSAk1Y C-HAN'GES) 0 DELETE (LD) NAME OF FIRM ,F(DtVj0f%10S MAILING ADDRESS "� -�l I I / k�wll " r-tF-,q ;ivOrk vzz-r 11C.0 r" 0 N 0 1 tv 1q. 9 so ZLO I BUSINESS PHONE -7 -) 5 - -7 -1 1 Q'k NATURE OF BUSINESS NIO. OF EMPLOYEES aL WO A� k' BUSINESS ADDRESS INDIVIDUAL PAR 1-NERSH-W CORPORATION _O YM 0 Al 0 -S (S) P OME ADDRESS T /1 OWNERS NAME HOME PHONE DATE OF BIRTH PLACE OF BIRTH 1SOCIAL SECURITY NUMBER EMERGENCY NOTIFICATION III NAME&TELEPHONE Z Lc 6-g� 'F -7 7D - 61 �f ki Ll (PLEASE LIST TWO) (2) NAME & TELEPHONE 6. � r-) o c r � 9D iq - 12 �' 'y - " WASHINGTON STATE TAX NO.-12(177411fcl APPLICANT'SSIGNA-r/Ur6-7--- DO INOT WRITE BELOW THIS LINE FILL IN LAND USE CODE, UFIR NUMBERS, ZONING, ETC. CHECK APPROVAL OR DISAPPROVAL, D,ATE, AND STAFF REVIEW: SIGN. IF DISAPPROVAL, PLEASE COMPLETE "COMMENT" SECTION. ROUTE TO NEXT DEPARTMENT ON LIST. PLANNING DEPARTMENT E- APPROVE 0 DISAPPROVE COMMENTS DATE SIGNATURE BUILDING DEPARTMENT DATE 0 APPROVE E] DISAPPROVE SIGNATURE COMMENTS: == CAPACITY: (NO. UNITS, APTS. OFFICES, SEATS, BEDS, STUDENTS) FIRE DEPARTMENT DATE 0 APPROVE El DISAPPROVE SIGNATURE COMMENTS: POLICE DEPARTMENT DATE SIGNATURE 0 APPROVE I--,' DISAPPROVE COMMENTS: PUBLiC WORKS DEPARTMENT 0 APPROVE 10I DISAPPR(,VE DATE SIGNATURE. LAND USE CODE: ZONING CODE F-=---=] I I 1 1-1 CONDITIONAL USE PERMIT = E= = Building El Hotel/Motel (L) Permit E-1 Apt. Bldg. (A) =]= 17] Office Bldg. (0) Occupancy EI Restaurant (R) Group 0 Hosp/Nurs Home (H) 0 School (S) U. F. 1. R. -T I F COMMENTS: ITY CL.E-RK ;--:F.-11JRN TO C, -,WOW i MOP', M', it Romfosl 5 I A tv iC 71� 0 4 7,t' Uri 0 �;j� C; L A? ;r 14 1.4 C Z--- 61 S- oy ox 6 c) IV (.6- 6L/4.. R .-A 6c oa MWII'DS PUBLIC F=-- A '.,LAMT' 24111 HwY. 99 (in Doces Warehouse) 775-7212 * * * * * *- * * * *� W, * *. *'� *� *. * *. *. * *' * * * *� * * * * * * * * * * * * *; * * * * * * H� F.WLLOW FUA TER I You. are personally invited to an open House for the new Edmonds Public Flea Marketl Yes, that Is right! A brand new public flea market, in a huge building, and in a great location ,4e are planting ourselves exactly -in the center of the la rgest population area in the entire Nortl,.westl Therefore we have an excellent clientalle to serve and.from . which to draw. Edmonds Public Flea Market is located in Doces Warehouse. IlTe have ample space now, with more space available as we agrow. The building is heated and well lighted. There a are loading docks for easy access, or if needed, you can drive Into the. center of the building. We also have a - large parking lot, with- space for more than 500 cars. 0 0 . We wrill be advertising in the Times, the P.I., the Everett Herald, and the Little rage with distribution of flyers to hundreds Mlickel. �rd -we will have extensive cove . I Jal buyers. upon 1hundreds of potent-& the public every Friday, Saturday, and Sunday, starting life will be olpen f or sales to Friday, lNovember 18th. Space sizes are 10 x 10 at a cost of "10.00 per selling day and 1Z 10 x 20 at a cost of $18.00 -jer selling day. if -you wish to leave your merchandise during the week, there will be no extrra charge - I . - -"T-i h a .6 In to sell. 4e are looking for a wide. variety of merchants It- qu 14ty,nerchandise We would lLce *x meet Tfith you as soon as possible to reserve yo= selling space for our ,,rand Open.ing! Call us at 77r--7212 or 365-7125. Cr better yet, sto-O by and see us this Taeekl We'll even buy you a curp of coffeel Your Friends, lathy '"' tigker and Roy Fox �/ �66 '44 ek �71 ACA LogF 4_Lt I 15, �1_1 ZI 14 e4 MWEDS. PUB* FIM W=T - SELLER INFMU*ON C6STS: 10 x 10 is, $10.00 per selling day; and a 10 xZO is $1'6.00 per selling day SRT.T- 0 HOURS: FRIDAYS 2:00pm to 8:00pm; both SATURDAYS & SUNDAYS 9:00am to 5:00pm YOUR ACCESS HOURS: All loading and un-loading should be' done during the following hours: THURSDAY: Noon to 4:00pm -Not open to the public FRIDAY: Noon to 2:00pm -Open to public for sales at 2:00pm-' 8;00pm to 9:00pm-1 hour to clea�-up and leave SATURDAY; 7:00am to 9:00am-Open to the public for sales at 9:00am 5:00pm to 6:00pm-1 hour to clean up and leave SUNDAY: 7:00am to 9':00am-Open to public -for sales.at 9;00am 5:00pm to 6:00pm-1 hour. to clean up and leave MONDAY: Noon to 4:.00pm -Rot open to the pub2.ic CLOSED TUESDAY AliD WEDNESDAY If you sell every Friday, Saturday, and Sunday there will.be no charge to leave your merchandise during the week. If you wish to reserve your booth for the following weekend, yoa must pay for it by 4:00pm Sunday. There will not be a reservation Ifee for our permanent!merchants. If you wish.to reserve a booth for one particular weekend or one particular day,*. I there will be a $2.00 charge. The booth must be paid for by 1:00pm'on Fridays and 8:00am on Saturdays ana 5aways or y4ur ra:survatiun ana tne fee will be forfieted. * We will not come around to collect fees. You,must come to the office. * You will be charaed for electricity only if your -usage is excessive. * Loud music or noise will not be allowed.'.'... * Lawn mowers, chain saws, or any othdir-gas powered machinery must be tested outside. * Please watch your children.I.Do not allow them to play in un-occupied areas of the build ing. * If you have questions about arWthing, please feel free to come into the office and talk with us. i7— —t YVO a.�) .Oow� 'i�� 0 oe-2 7c: V 7' C >2 -;t;"V -i:, --4000;��.I�a 0,0,00Y J,0000,4�1�� av�z —ZI/ 0 —Sl —Z -/�Xlg 0000lv - f--1 _PV-tR no wo ;5v F- -I L-A 0 CA 1-7 -45' A/ Y 6 -99-/Z.E 7777 77- T-H ri�- O/U rk�Z4 /9/,F- 6V C- 0-/- Q-0 -S --co C)C)cAr'o' -S� e LJ E) A46iz co Qocl t% WA i 1- 4 -81. cp aqoo t 80 c-,o sc-�- q - I :sq q -Oa3� 0 0 APPLICATION FOR PERMIT FOR MATERIALS OR PROCESSES 531-000-015 DATE: Mai 1 To: Mr. Jack D. Weinz, Fire Chief Edmonds Fire Department 250 5th Ave. North Edmonds, 14A 98020 Dear Sir: In conformity with the terms of the Fire Code, application is hereby made to store, use, or maintain the following specific materials or processes: Assembly Room --Occupant Load 106 The materials or processes are at the,following specific loca- tions at the below address: Name of Firm or Company Doces Address (Street and Number) 24111 Highway 99, Edmonds Signature Title 9/791v 0 0 1 "0 CITY OF EDMONDS HARVE H. HARRISON MAYOR CIVIC CENTER - EDMONDS, WASHINGTON 98020 * (206) 775-2525 FIRE DEPARTMENT May 14, 1982 Doce's 24111 Highway 99 Edmonds, WA 98020 Dear Sir, Some time ago we received the enclosed check for an Edmonds Fire Permit. However, we did not receive the necessary completed application for said permit. Your office was contact several times but the application was never sent. Since your business is no longer operating, we are returning the check so that you can clear your records. BE Sincerely, Barbara L. Eyrish Secretary PLEASE DETACH BEFORE CASHING CHEC THIS CHECK IS TENDERED IN FULL PAY map F INVOICES LISTED a No. 20996 DA!;r'- INVOICE NO. DESCRIPTION GROSS AMOUNT DISCOUNT BALANCE IZ/17/81 Fire Dept X permit 171673 5.00 DOCES,INC. EDMONDS, WASHINGTON SEATTLE-FIRST NATIONAL BANK HEAD OFFICE BRANCH SEATTLE, WASHINGTON No. 20996 PHONE 774-2141 19-2 24111 HIGHWAY 99 1250 EDMONDS, WA. 98020 DATE CHECK NO. 12/17/81 20996 _,AMOUNT PAY Five dollars and no cents TOTHE Cityof Edmonds ORDER Edmonds Fire Dept OF 250 5th Ave No Edmonds, Wa. 98020 ATT:Mr. Jack Weinz II9020996,i16 1: 12SO000241: LIS? **$5.00**** VOLD NOT CASHUD 60 CA V 5 CITY OF EDMONDS HARVE H. HARRISON. MAYOR CIVIC CENTER - EDMONDS. WASHINGTON 98020 * (206) 775-2525 FIRE DEPARTMENT July 8, 1981 Doces Furniture Mr. Dean Doces 24111 Highway 99 Edmonds, WA 98020 Dear Mr. Doces: An inspection of your Edmonds store was made on July 7, 1981, at which time several hazards were noted. We realize you are in a changing situation and have noted your need for some flexibility, but there are some conditions which must be corrected immediately. They are as follows: 1. Clear and maintain the driveway on the east side of the building. This is for Fire Department access to the sprinkler connection and for drive - through access with the fire engines. 2. Clear away the brush and blackberry bushes from around the sprinkler connection. 3. Remove any stock stored on racks in the warehouse which obscure the required 18' clearance from sprinkler heads. A reinspection will be made on July 14, 1981, to check on your compliance. If you have any questions, please contact this office by calling 775-2525, Ext. 234, between the hours of 8 a.m. and 5 p.m., Monday through Friday. Yours for a safer community through fire prevention, Sincerely, Stanley A. Olsen Senior Fire Inspector SAO: sr TO Build . ing Dept. Hal Reeves rOAM 41 - LITTLE'S SUBJECT: Doce' s INTER -OFFICE COMMUNICATIONS DATE '11j"6 11-191P. FROM Fire Dept. Stan Olsen Doce' s ha's closed the Scuth Center store and they are moving �at stores stock to the Edmonds store. All the 'former tenants have -been moved out. The center two story area is being remodeled to add office space by the addition of numerous partitions , ect. Temporary lighting -is in pla'ce with exposed connections ect. The upstairs area is being restored to showroom display purposes. We were there on 6-18-81 on a reinspection.We are trying to get them to repair the wiring, provide spare sprinkler heads and install a guard ra.il. They have in the past used the excuse of remodeling and the cond1tions continue. My concern, is that they are changing wiring , exit conditions, sprinkler coverage, ect with out review by the Building Dept. or Fire Dept.