303 WALNUT ST.PDF11111111111111
13719
303 WALNUT ST
ADDRESS:
TAX ACCOUNTIPARCEL NUMBER: 2-7032`300111000
BUILDING PERMIT (NEW STRUCTURE): � ab - I 3SL4
COVENANTS (RECORDED) FOR:
CRITICAL AREAS:Iai I DETERMINATION: D Conditional Waiver F] Study Required Awaiver
DISCRETIONARY PERMIT #'S:
DRAINAGE PLAN DATED: 511-001
PARKING AGREEMENTS DATED:
EASEMENT(S) RECORDED FOR:
PERMITS (OTHER): OUR 0
PLANNING DATA CHECKLIST DA
SCALED PLOT PLAN DA`
SEWER LID FEE
'ED:
C) 9 liq
LID #:
SHORT PLAT FILE: LOT: BLOCK:
SIDE SEWER AS BUILT DATED:
SIDE SEWER PERMrF(S) #:
GEOTECH REPORT DA
STREET USE / ENCROACHMENT PERMIT #:
FOR:
WATER METER TAP CARD DATED:
OTHER:
LATEMP\DSrs\Fomts\Street File Checklist.doc
a
CITY OF EDMONDS
STATUS: ISSUED
Expiration Date: 8/30/2008
121 5TH AVENUE NORTH - EDMONDS,WA 98020
PHONE� (425) 771-0220 - FAX� (425) 771-0221
ernn
Parcel No: 27032300411000
PROPERTY OWNER APPLICANT CONTRACTOR
WALNUT ST CONDO (DUPLEX) GLENN GALLAUGHER SCL ENTERPRISES
536 WALNUT ST #201 536 WALNUT ST #201 17921 LINDEN AVE N
EDMONDS, WA 98020 EDMONDS, WA 98020 SHORELINE, WA 98133
206-604-1717 206-604-1717 206-226-6673
LICENSE 4: SCLENL*OOIK4 EXP:5/22/2008
DUPLEX
VALUATION: $336,117
PERMIT TYPE. Residential
PERMIT GROUP. 20 - Duplex
GRADING Y CYDS: 156
TYPE OF CONSTRUCTION: VB
RETAINING WALL ROCKERY: N
OCCUPANT GROUP: R3
OCCUPANT LOAD: 22
FENCE: N ( 0 X 0 FT,)
CODE 2003
OTHER. N ------- OT HER DESC�
ZONE PM-1.5
NUMBER OF STORIES: 3
VEST ED DATE�
,NUMBER OF DWELLING UNITS: 2
01HOW N
1BASEMENT 0 1 sr FLOOR. 0 2ND FLOOR 0
m
BA EMENT� 0 tST FLOOR: 674 2ND FLOOR 1620
13RD fLOOR. 0 GARAGE. 0 DECK: 0 OTHER: 0
13RD FLOOW 1620 GARAGE: 571 DECK: 65 OTHER 0
rRONTSEFBACK SIDESEFBACK REARSEYBACK
,EQUIRED: S 15 PROPOSED: 15 ;D: E 10 PROPOSED: 20 IREQUIRED: N 15 PROPOSED: 15
IE16,11T ALLOWED.30 PROPOSED:29.97 REQUI RE D: W 10 PROPOSED 10 1
VTBACKNOTES PARKING 31NGARAGE, I OUTSIDE. MAX HEIGHT IS30,(25+5). PORTION OFSl-AIRSENCROACHPURSUANT TOECIA
6,30 040 D (I I - MIN FROM PL, 12 83- SHOWN).
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULAT ING CONSTRUCT ION AND IN DOING T HE WORK AUTHORIZED
THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELAT ING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27
'1111SAPPI-ICAI'IONISNO�TAPERM-U UNTILSIGNEDBY THE BUILDING OFIICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID
Olt R
Print Nanne Date
F.11-mial 11131111
11 IS UN I. AWFUL TO USEOROCCUPY A BUILDING OR S1RUC'[`U RE UNTIL A FINA L INSPECflON I IAS BEEN MADE AND APPROVAL ORA CER'IIFICAIy 01:
OCCUPANCY HAS BEEN GRANJED. UBC109/ IBC I 10/ IRCI 10.
ARCHIVE APPLICANT ',SSfNSOR OTHER
[y]
ft
0
STATUS: ISSUED BLD20061384
CONDITIONS
Lot line stakes must be in place at the time of foundation/setback inspection.
All new, extended, re -built or relocated electrical utility and/or service shall be placed underground.
Approval of this foundation design is conditional subject to inspection of existing site soil conditions.
Retaining Walls must be designed and constructed to resist the lateral pressure of the retained material.
Provisions must be made for the control and drainage of surface water around buildings.
• Installer shall provide the manufacturees installation, operating instructions, and a whole house ventilation system operation
description. A label shall be affvcd to the whole house tinier control that reads "Whole House Ventilation" (see operating
instructions).
• Maximum Height 25 feet. Measured from average elevation of undisturbed soil at comers of extended building rectangle.
Subject to field check by building department.
Hose Bibbs (exterior faucets) are required to have a pen-nanently affbed anti -siphon device installed.
In addition to the required pressure/relief valve, an approved listed expansion tank shall be installed on all hot water tanks. Per
UPC 608.
Ty pe B or L vent connectors required on fuel-buming appliances pas s ing through unheated s paces. Per IMC 803.2
Obtain Electrical Perryfit from State Department of Labor & Industries. 425-290-1309
Pursuant to UPC 605.2 a water service shutoff shall be installed on the water line as it enters the building.
City approved plastic piping may be used in water service piping provided that where metal water service piping is used for
electrical grounding purposes, replacement piping shall be of like materials (UPC 604.8). A state electrical permit and
inspection is required if electrical grounding is altered, removed, improved, or added. Contact State Dept. of Labor &
Industries Electrical Division at 425-290-1309.
Any request for alternate design, modification, variance orother administrative deviation (hereinafter "variance") from
adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing
fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable.
Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been
specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision
of city code or state law does not approve any items not to code specification.
Pursuant to UPC 608 a pressure regulator valve (PRV) shall be installed near the water shutoff.
Sound/Noise originating froniternporary construction s ites as a result of construction activity are exempt from the noise limits
of ECC Chapter 5.30 only during the hours of 7:00amto 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding
Sundays and Federal Holidays. At all other times the noise originating from construction sites/activites must comply with the
noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
THIS PEROT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE
PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION.
PERMITTIVE LIMIT. SEE ECDC 19.00.005(A)(6)
BLUIDING (425) 771-0220 E)CF. 1333 1 ENGE4�13 (425) 771-0220 EXT. 1326 1 FIRE (425) 771-0215
I PUBLIC WORKS (425) 771-0235 1 PRETREATRwr (425) 72-5755 RECYCLJNG (425) 2754801 J
IWhen calling for an inspection please leave the folloyAng information: Permit Number, JobSite Address, Type of Inspection being
requested, Contact Name and Phone Number, Date Prefereed, andAbether you prefer morning or afternoon. I
E-Erosion Controt/Mobilization
E,Ston-n Tight line
E-Storm Detention System
E-Footing Drain Connection
E,Water Service Line
E-Driveway Form& Slope Ver.
I
ft go
E-Cross Connection Final
EEngineering Final
B-Setbacks
B-Footings
B-Foundation Wall
B-Isolated Footings/Piers
B-Retaining Wall
B-Slab Insulation
B-Plumb Ground Work
B-First Floor Framing
B-Plun-b Rough In
B-Gas Test/Pipe
B-Equipment-Mech
B-F.verior Sheathing
B-ShearNailing
B-Height Verification
B-Framing
B-Wall Insulation/Caulk
B-Floor Insulation/Caulk
B-Ceiling Insulation/Caulk
B-Sheetrock Nail
B-Building Final
F-Fire Final
I
I
I
OWNE
GLENN GALLAUGHER
116,- 0:'
05.00' PROPERTY LINE
31.1 CONC.
LANDIWG
-\
20 0
F:�
. . I
1 A PARKING PAD.
J, 0
F- STAIRS
W".
4
LINE OF
FLOOR ABv.
IL
(L
SEW Ill ILLJ
z
14% 5T �lu
GARAGE 4SAT
FINISHED GR46E 51,13-
'SLOP
Mr 58.70,
UF 68.031
RIDGE 81.10,
4:0
>
*
lq
0 1 - I *
luo oil
..4 .,r 1
1�--O'
3-5 --o"
Fo-, 0, - 0
65.00' PROPERTY
-;'"— - . ' - r �IkE
SIDEUf4L<
LAI,
GRASS
61, CURB
FILE
WALNUT STREET
- — - — - — - — - —
SITE ADDRESS
301 WALNUT ST
EDMONDS, WA
TAX ACCOUNT FARCELO
IMPERVIOUS AREA
ROOF FOOTPRINT
IC320
sp
DRIVEWAY / PARKING
491
SP
(NOT COVERED BY ROOF)
WALKWAY
SO
Sp
TOTAL IMPERVIOUS AREA
2501
SP
LOT COVERAGE
LOT AREA 4355 SF.
ROOF FOOTPRINT IS20 S.F.
IS20 / 4355 44%
I
I
DATUM
POINT
53.48'
HEIGHT
CALCULATIONS
A 5025'
B 52.00'
AVE. GRADE
51.13,
ACTUAL RIDGE
81.10,
81.10, - 51.13,
2 43. S 1'
MAXIMUM HEIGPT 30'
Zone P-M-i-5 Comer — Flag
Le-t_b a c k s t �ur e d
Actual
Front IV
Sides C-jW 10 110
Rear 15
Other
Height +5
FLOT FLAN,
SCALE: I"=20'-O"
U9
>b �
0
CA File No.
Critical Areas Checklist
Site Information (soils/ topography/ hydrology/ vegetation)
1. Site Address/ Location: 3o k uja�.J.
2. Property Tax Account Number: '2_1-p3,2_j00q \\(>CC>
3. Approximate Site Size (acres or square feet): 5-bot 5a,J��.
4. Is this site currently developed? V j
,yes; — no.
If yes; how is site developed? 7�a o.%\!4 �>es,
5. Describe the general site topography. Check all that apply.
Flat: less than 5-feet elevation change over entire site.
Rolling: slopes on site generally less than 15% (a vertical rise of 10-feet over a horizontal
distance of 66-feet).
Hilly: slopes present on site of more than 15% and less than 30% ( a vertical rise of 10-feet
over a horizontal distance of 33 to 66-feet).
Steep: grades of greater than 30% present on site (a vertical rise of 10-feet over a horizontal
distance of less than 33-feet).
Other (please describe):
6. Site contains areas of year-round standing water: W 't ; Approx. Depth:
7. Site contains areas of seasonal standing water: N lr� Approx. Depth:
What season(s) of the year?
8. Site is in the floodway N 0 floodplain,— of a watercourse.
9. Site contains a creek or an area where water flows across the grounds surface? Flows are year-round?
N 13 - Flows are seasonal? (VVhat time of year?
10. Site is primarily: forested meadow shrubs mixed
urban landscaped (lawnshrubs etc) !I e-&
11. Obvious wetland is present on site: Vj
For City Staff Use Only. 0,07)
1. Plan Check Number, if applicable?
2. Site is Zoned? 1- 6.
3. SCS mapped soil type(s)? _Z_'t j I t7'L- o a m cl 6p C.�,
4. Critical Areas inventory or C.A. map indicates Critical Area on site? -NO
5. Site within designated earth subsidence landslide hazard area? 0 -
DETERMINATION
STUDY REQUIRED WAIVER
Reviewed by: C, I vj o, M apj'a- (,o cci a,— Date: 09-717-.2100(0
Critical Areas Checklist.doc/3.19.2001
a
OV ED_4
City of Edmonds
V Development Services Department
Planning Division
Phone: 425.771.0220
PC. Fax: 425.771.0221
The Critical Areas Checklist contained on this form is to
be filled out by any person preparing a Development
Permit Application for the City of Edmonds prior to
his/her submittal of the application to the City.
The purpose of the Checklist is to enable City staff to
determine whether any potential Critical Areas are, or
may be, present on the subject property. The information
needed to complete the Checklist should be easily
available from observations of the site or data available at
City Hall (Critical areas inventories, maps, or soil
surveys).
Date Received:
City Receipt #:
Critical Areas File #: ov, -,koo6r', ni 7,,9
Critical Areas Checklist Fee: $45,00
Date Mailed to ADDlicant: ql&�761o?mC
A property owner, or his/her authorized representative,
must fill out the checklist, sign and date it, and submit it
to the City. The City will review the checklist, make a
precursory site visit, and make a determination of the
subsequent steps necessary to complete a development
permit application.
Please submit a vicinity map, along with the signed copy
of this form to assist City staff in finding and locating the
specific piece of property described on this form. In
addition, the applicant shall include other pertinent
information (e.g. site plan, topography map, etc.) or
studies in conjunction with this Checklist to assistant staff
in completing their preliminary assessment of the site.
The undersigned applicant, and his/her/its heirs, and assigns, in consideration on the processing of the application agrees
to release, indemnify, defend and hold the City of Edmonds harmless from any and all damages, including reasonable
attorney's fees, arising from any action or infraction based in whole or part upon false, misleading, inaccurate or
incomplete information furnished by the applicant, his/her/its agents or employees.
By my signature, I certify that the information and exhibits herewith submitted are true and correct to the best of my
knowledge and that I am authorized to file this applicatio on the behalf of the owner as listed below.
SIGNATURE OF APPLICANVAGENT DATE /J7 — J)(,
Property Owner's Authorization
By my signature, I certify that I have authorized the above Applicant/Agent to apply for the subject land use application,
and grant my permission for the public officials and the staff of the City of Edmonds to enter the subject property for the
purposes of inspection and posting attendant to this appOcation.
SIGNATURE OF 0 WNER
Owner/ -Applicant:
Name
.53(" cjmt,,,�- :&�
Street Address
� -J
7
City State Zip
Telephone: -?n(, - oo-(
Email address (optional):
DATE
Applicant Representative:
Cu rJ I.Sc Cd
Name
1-7�,t f L-j, A-t, &,
Street Address
City State Zip
Telephone: -,0 6 - Z Z 6-0-?g
Email Address (optional):
Critical Areas Checklist.doc/3.19.2001
0
LANNIN
,LG-DA,TA
(�e5wenTffr=111 Q��rojects
STREETF=ILE
Name: C11-evin (10IHOLLAIO�Ilelr
Date: 0
SiteAddress: �,03 Wai VILA+ (�p-tYfff-
Plan Check #: BLD-200b- 13 a &J
Project Description: NEW '
.2..-LAVIN- dLAPit'i (bon"S,)
Use(s) Proposed:
e-,.%
Allowed Use: ("S NO)
CUP File Number:
To Allow What Uses:
Legal Nonconforming Land Use Determination Issued: (YES
Reduced Site Plan Provided: (y
,!JSNO)
Zoning: F- M -I - G
Map Page:
Comp Plan Designation: VJ
Corner Lot: (YES
Flag Lot: (YES / VO A/
ADB File Number (date waived): /A--
Lot Area: L�'3r915 10 01
ON st-,
Plans Match ADB Approved: (YES / NO) t4 JA
Shoreline Required: (YES w k \r
Critical Areas Determination #: Ar (rp % 0( Z,
EI Study Required - WOO
Waiver +
i
SEPA -Determination:
v Exempt i IF (V C, Y'd eg r a
El *Needed (for sites with 500 cubic yards of grading or within 200feetof Puget S ndorLake
4 t r
Ballinger. Requires: (1) Fee, (2) Envir nmental Checklist, and (3) APO List wit notarized form).
Re Setbacks
Street
Side: —
S
Sid .. e:
I W 10
R r:
ActualSetbacks
Street:
Side:
Side:
Rear:
Lot Coveeage/ Required:
Lot Coverage/F)4 Provided:
Lot Coverage/F,* Calculations. MDf-[f00+-PV1VJ+
Buildin Height
Datum Point: M J+ (WA V1 LA_�)
Datum Elevation: 15 r5
Maximum Height:
Actual Height:
Subdivision:
Lot Aggregation Required:
Landscaping
Landscaping Matches AD13 Approved: A --
Landscaping Bid Provided: (YES / NO)
Bond Amount (100% Bid):
fe-
ideng
Plan Review By: 9-e;W ed�
0 PLANN ING DATA 0,
New Commercial / Multi -Family Projects
I
STREET=F
_ 7ILE
Commercial EaLk�in A nalysis
Parkihg Tinant Required
Business Name Type/Use
Ratio Area Parking
Total Parking Required. -
Total Parking Pro vided.-
Multi-Family ParkbW Anal is
# Bedrooms per Dwelling Unit
4
Parking Ratio
# Units
Required
Parking
Studio
1. 2/13. U.
I Bedroom
1.5/D.U.
2 Bedrooms
1.8/D.U.
3 + bedrootns
2.0/D.U.
Total Parking Required.-
+
WV, \1
W Vi Total Parking Provided,-.
't
�J C-2 P 0 tsp T4 -e, (a r POt OLA4',�?fa-2- -�O t)A-C A_,OV/r�
Other
C, P 10 a e- i
I-D4. YC)
4 30'
4�A
Kd �f rq—
Plan Review By: gr�w aa�
STANDARD
w
OWNER:
IL S6 I -
-7
U)
L0
w
V
0
0
M
0
Lo
LD
LD
EN
LD
CD
CD
C*4
Ln
0
DETENTION S YSTEM- WORKSHEET
(500 0 SF OR LESS)
ADDRESS: ;501 ;wAua WT CALC. BY: Yk L2#f//S
21 a:
7q EV PHONE: =U" -OL
AMC- DATE:
IMPERVIOUS SUFACE AREA PIPE DIA. ,,a, PIPE LENGTH ORIFICE
FOOTING DRAINS SHALL NOT
RIM ELEV.
DETENTION PIPE LENGTH
FINISF)fED
q'M E
DETENMN PIPE LENOW
ffD
GRADE
MUM
11MI NAUM
0Z% To 1.8%, SLOPE
UPPER CATCH BASIN
ELEV.-�
BE CONNECTED TO DETENTION SYSTEm
OCKING LID (TYP.�
IM EI-IiM
rG" MIn. dwerance
-Measuradfrorntmnof t
Mal"
Con c. bDx or Hear.
To CITY CONVEYA14CE
4NV. INV. ELEV.
FtEv.
CONTROL
COUTROLOS, a. fIN :i�RIFICE 5;/13"PS
2'X2'Xl2* DEEP CONTROL CATCH EIASN� SUMP
(4'-S' QUARRY SPALL6 OR EQUAL)
FROM OONTROL�6--,
IN' �'r C0V--R
SHALL BE PERPENDICULAR
TO r3PREADER TRENCH-
PERF. PIPE SHALL BE
LEVEL & CAPPED AT ENDS
RIPRAP OUTLET
1
CONTROL CB
TRENCH SKALLBE UN ED
NTH WRAFf &ON TOP
VMH 50 DRAIN ROCK
SPREADER TRENG14
L;I-FY 5TORM
CONVEYANCE
SYSTEM
8PREADERTRENCH
SHALL BE ANN.
OF VY LONG AND
PERPENDI]CULAR
TO CONTROL CEI,
09701"1
27
BUILDINO -DEp
CITY oF m
NOTES
1. CALL ENGINEERING DIVISION (-771-022DEj<7.1326) 24 HOURS IN ADVANCE FOR A TIGHTLINE AND DETENTION
SYSTEM INSPECTION BEFORE BACKFILLING AND FOR FINAL INSPECTIONS. -APPROVED BY
2. -ResponsiNlity for operatfon and maintenance of drainage systems on private property is the responslUlfty of the property
The outlet control orifice must be kept. open at a] I times.
owner. Material accumulated In the storage pipe must be flushed out and removed frarn catch basins to allow proper operation. 14-7
PA TE
a
ThAb Ct*tw n; FAmnnrle
Side Sewer Drawing
EASEMENT NO - --------------------- ------- --------------
lol-o4200 NEW CONSTRUCTION REPAIRS F1 LID NO - ------------------ - ASMT. NO - --------
OWNER ........ ROBERT SAMMONS
- ------------------------------------------------------------------------------------ CONTRACTOR ............ - ---------------------------------------------------------------------- PERMIT NO - --------------------
JOB ADDRESS ---- ------------------------- LEGAL DESCRIPTION: LOT NO - -------------------------------------- BLOCK NO . ...................... _
................................................................ .....................
NAME OF ADDITION --- ...................... ....... ........
co
rn
M
q
rn
DYE TESTED ON SEWER
Approved:
PWW-OWl-1 1175 (REVA 1/78) DATIE ....................................... ---- BY --------------------------------------------------------- —
04
AO
DEPARTMENT OF BUILDINGS
PER INTERNATIONAL RESIDENTIAL CODE SECTION R110
AT: 303 Walnut Street
Occupancy established by this certificate: R3
No. Stories:- 3 Basement: N/A
Building Permit #: 2006-1384
Dwelling Units: 2
Type of Construction: VB
M
Owner of building: Walnut Street Duplex (Condominium)
The Duplex at 303 Walnut Street —has bee ' n inspected and approved complying with the requirements
of the 2003 edition of the International Residential Code as adopted by the City for -the group and division of occupancy and the use for which
the proposed occupancy is classified.
Issued this 7 th day of July, 2009
Chief Building Official
By:
Any change of occupancy or use requires a building permit and a new Certificate of Occupancy issued by the City of Edmonds Building Official.
STREff Fil't
CITY OF EDMONDS
121 5TH AVENUE NORTH - EDMONDS,WA 98020
PHONE: (425) 771-0220 - FAX: (425) 771-0221
STATUS: ISSUED
Permk Number: ENG20070379
Job Address: 303 WALNUT ST, EDMONDS
PROPLKINOWNLIt CONTRACTOR
GALLAUGHER SCL ENTERPRISES
303 WALNUT STREET
17921 LINDEN AVE N
EDMONDS, WA 98020 SHORELINE, WA 98133
206-226-6673
LICENSE #: SCLENL*00 I K4 EXP: 5/22/2008
ENG20070379
DESCRIPTION OF WORK:
3/4 water meter for one duplex unit. Meter location on Walnut in landscape strip. Services were tapped off main With City water main
project.
METER SUE: 5/8 " + 3/4 " I
N NEW SERVICE FROM CITY MAIN TO PROPERTY LINE
N ASPHALT/CONCRETECUT
N FINA L PATCH BY CONTRA CTOR
OWNERNAME:
BILLING ADDRESS:
INSTALLATION FEE: $550.00
CONNECTION FEE: $908.00
STREET CUT DEPOSIT: $0.00
N SFR IRRIGATION FRI A PARTM ENT / CONDO - UNITS:
Y DUPLEX FIRE CONNECTION I N I MIXED US&COMMERCIAL FLOORS
• TRIPLEX N OTHER--
• COMBO FIRE/DOMESTIC BACKFLOW ASSEMBLY REQUIRED
METERNUMBER--
STYLE:
M ETER REA DINGr.
MANUFACTURER!S #:
METER LOCATION:
SERVICE MATERIAL:
DATE OF WORK:
REMARKS:
U/B A CCOUNT:
READ AFTER ADDRESS:
RESIDENTIAL UNITS: 0
PROJECT NUMBER:
LOCATE REQUEST #:
DATECAIJ ;
AND
REGISTER
PRESSURE: 0 GPM: 0
WORK BY:
***ATTACH DRAWING WHEN NECESSARY***
ROUTE:
WATER SUPPLIER:
ISSUED
TYPEOFREPAIR
Asphaft Roadway/Walkway
FN7 Concrete Sidewalk
r-N I Concrete Curb
AREA REPARM
(0 Ft X 0 Ft ) = 0 Sq. Yds
(0 Ft X 0 Ft ) = 0 Sq. Yds
(OFt X OFt)=OSq.Yds
(0 Ft X 0 Ft ) = 0 Sq. Yds
(OFt X OFt)=OSq.Yds
(OFt X OFt)=OSq.Yds
0 Lineal Ft
0 Lineal Ft
0 Lineal Ft
ENG20070379
REPAIR COST
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
Total Repair Costs: $0.00
Less Street Cut Deposit: $0.00
Invoice/Refund: $0.00
0 0
"77 777 7;! r
CITY OVEDNI"NDS
121 5TH AVENUE NORTH - EDMONDS,WA 98020
PHONE: (425) 771-0220 - FAX: (425) 771-0221
STATUS: ISSUED
Permh Number: ENG20070377
ENG20070377
Job Address: 303 WALNUT ST, EDMONDS
PROPIRINONVNER CONTRkCTOR
GALLAUGHER SCL ENTERPRISES
303 WALNUT STREET 17921 LINDEN AVE N
EDMONDS, WA 98020 SHORELINE, WA 98133
206-226-6673
LICENSE #: SCLENL* 00 1 K4 EXP: 5/22/2008
DESCRIPTION OF WORK:
3/4 water meter for irrigation. Meter location on Walnut in landscape strip. Services were tapped off main with City water main project.
METER SUE: 5/8" + 3/4" 1
• NEW SERVICE FROM CITY MAIN TO PROPERTY LINE INSTALLATION FEE: $550.00
• ASPHALT/CONCRIETECUT CONNECTION FEE: $908.00
• FINAL PATCH BY CONTRACTOR STREET CUT DEPOSIT: $0.00
OVINERNAME:
BILLINGADDRESS:
• SFR IRRIGATION F7N APARTMENT / CONDO - UNITS: 0
• DUPLEX FIRE CONNECTION F-N-1 MIXED USE -COMMERCIAL FLOORS: 0
• TRIPLEX 20THER- RESIDENTIAL UNITS: 0
• COMBO FIRFIDOMESTIC BACKFLOW ASSEMBLY REQUIRED
PUBLICNVOIII�S INSTA LL VFION-t,-I'ILn'YB ILLING
LOCKED I N I UNLOCKED PROJ NUMBW-
METERNUMBER. LOCATE REQUEST #:
STYLE: DATECAII
METER READING. AND
MANUFACTURER!S #: REGISTER
METERLOCATION:
SERVICE MATERIAL: PRESSURE: 0 GPM: 0
DATE OF WORK: WORK BY:
REMARKS:
***ATTACH DRAWING WHEN NECESSARY***
UB ACCOUNT: ROUTE:
READ AFTER ADDRESS: WATER SUPPLIER.
# - 1. 0 0
ISSUED
TYPEOFREPAIR
F 7N Asphalt Roadway/Walkway
FN--] concrete Sidewalk
= Concrete Curb
ENG20070377
AREA REPAHUD REPAtR COST
(OFt X OFt)=OSq.Yds $0.00
(OFt X OFt)=OSq.Yds $0.00
(OFt X OFt)=OSq.Yds $0.00
(OFt X OFt)=OSq.Yds
$0.00
(OFt X OFt)=OSq.Yds
$0.00
(0 Ft X 0 Ft = 0 Sq. Yds
$0.00
0 Lineal Ft
$0.00
0 Lineal Ft
$0.00
0 Lineal Ft
$0.00
Total Repair Costs: $0.00
Less Street Cut Depos it: $0.00
Invoice/Refund: $0.00
Ov EDAI
-k
CITY OF EDSMN
121 5TH AVENUE NORTH - EDMONDSMA 98020
PHONE: (425) 771-0220 - FAX: (425) 771-0221
I j;C0
STATUS: ISSUED ENG20070378
Permk Number: ENG20070378
Job Address: 303 WALNUT ST, EDMONDS
PROPEWFYOWNER ('0NTlt%(-TOR
GALLAUGHER SCL ENTERPRISES
303 WALNUT STREET 176921 LINDEN AVE N
EDMONDS, WA 98020 SHORELINE, WA 98133
206-226-6673
LICENSE #: SCLENL#00 I K4 EXP: 5/22/2008
DESCRIPTION OF WORK:
3/4 water meter for one duplex unit. Meter location on Walnut in landscape strip. Services were tapped off main With City water main
project.
NIETER SUE: 5/8 " + 3/4 "
N NEW SERVICE FROM CITY MAIN TO PROPERTY LINE
N ASPHALT/CONCRErECUT
N FINAL PATCH BYCONTRACTOR
OWNERNAME:
BILLINGADDRESS:
INSTALLATION FEE: $550.00
CONNECTION FEE: $908.00
STREET CUT DEPOSIT: $0.00
• SFR IRRIGATION FN7 A PA RTMENT / CONDO - UNITS: .0
• DUPLEX FIRE CONNECTION FN-] MIXED US&COMMERCIAL FLOORS: 0
• TRIPLEX MN OTHER. RESIDENTIAL UNITS: 0
• COMBO FIRE/DOMESTIC BACKFLOW ASSEMBLY REQUIRED
STYLE:
MErERREADING:._
MANUFACTUREI;VS#:-
METERUDCATION:
SERVICE MATERIAL:
DATE OF WORK:
REMARKS:
PROJECT NUMBER.
LOCATE REQUEST #:
DATECATI
AND
REGISTER
PRESSURE: 0 GPM: 0
WORK BY:
***ATTACH DRAWfNG WHEN NECESSARY***
U/B A CCOUNT: ROUTE:
READ AFTER ADDRESS: WATER SUPPLIER:
0
ISSUED
TYPE OF REPAIR
F—N-1 Asphaft Roadway/Walkway
FN --- 1 Concrete Sidewalk
F—N-� Concrete Curb
AREA REPAIM
(OFt X OFt)=OSq.Yds
(OFt X OFt)=OSq.Yds
(OFt X OFt)=OSq.Yds
(OFt X OFt)=OSq.Yds
(OFt X OFt)=OSq.Yds
(OFt X OFt)=OSq.Yds
0 Lineal Ft
0 Lineal Ft
0 Lineal Ft
Total Repair Costs:
Less Street Cut Deposit:
Invoice/Refund:
ENG20070378
REPAIR COST
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0,00
$0.00
$0.00
$0.00
j
I..) C. 1 B913
0
GARY HAAKENSON
CITY OF EDMONDS MAYOR
121 5TH AVENUE NORTH - EDMONDS, WA 98020 - (425) 771-0220 - FAX (425) 771-0221
Website: www.d.edmondsma.us
DEVELOPMENT SERVICES DEPARTMENT
Planning - Building - Engineering
September 11, 2007
MEMO TO:
Edmonds School District
Verizon Northwest
SNOCOM Police and Fire Dispatch
SNOPAC
Snohomish County E911
U.S. Post Office
Snohomish County Assessor's Office
Snohomish County Information Services
Snohomish County P.U.D.
Puget Sound Energy
Edmonds Fire Department
Edmonds Police Department
Edmonds Utility Billing
Edmonds Public Works
Edmonds Building/Street File
Edmonds Address Files
Lynnwood Disposal
Comcast Cable
Waste Management Northwest
Please be advised that the attached addresses have been added to the Edmonds address
system: Existing addresses of 301 Walnut St (original structure demolished) has been
changed to 303 Walnut St (New Duplex under construction).
Occupancy: R3 Tax ID Number: 27032300411000
Plat File/Design/Permit File: BLD2006-1384- Lot #'s N/A
If you have any questions regarding this letter, please contact me at 425-771-0220 or
Umbaugh@ci.edmonds.wa.us. Please contact me if you wish to be removed from this list.
lRoesful
p ctlu'ly,
T eresMaUmbaugb
Permit Coordinator
Edmonds Building Department
L\Temp\DS1"s\M aster Letters\New Address9/11/2007
Incorporated August 11, 1890
Sister Citv - Hekinan. Janan
0
"7D V'S
J10
Ibb �?j
J,
JO
"Ai
70?
IFS
Y,?.100 10, 7,9
c
14 170 17�
Q
I;r-O - - �;,/ T -10,
0
7,�, 'V41
%
le�
4, 7, 11b -Z�
CL.
IV07
'?6
110 'T
El Ca�ftan d's
In
VIA 200 Sani -
too 11�
145
- 140 12
1 12
Dal IN - DAYTON ST 13
-Alt
12 2
*2
U) m 9 A Old Millto
IF 1 110 0 �1- 210 2 209 201
E
03 c ca (0) 8 - U) 221 216 215
0 EL ul
tu- no w 210
ISO E > 222 >
-0 r 223 > 221
C', , < <
#4 or Sq W a) IQ tj Jasper M 225
10 22
2,24 5
C
9 232 -W
170 E W 0 22 2.
30 Stindowner Alder 229
230
Hole
217 303
160 #8 0) 219 -239 -
3z: (-) 0 233 242 306
#6 A
308
SU 314 Viq g1c 315
AlVmfte U) - 250
c 317
0. z 304 318
C- 402
324 Q
) 263 410
260
328 267 420 W.
LU _J-
Wildlife- . l!i—
[is ISIS 154 . ..... 338 2 271
424
.R6fuae: 275 Bank 437
405 L
,A,
-Z
404
8 32
414 412 410 408 504 505
404 400
9
420
511
515
424
Edrrionds Park
A
'ILI
V6
101?
1-10
49
-RIO 0,
y
10,
101. -10
FNAAP
If
70 1 7'. Iq
an,
"0
V.
10
Ve
N-
4
774 -S
106
CO 10,
Q-
o 123
El Ca�,tan
io
Bank 128
180
>
145
122
24
Ell 130
A DAYMN ST
12 203
90 82
Old Mi
110 o 209 209 201
#3 C cis E — 202
0) 221 216 fi) 21S
ul 222 lu
180 E > 220 w — 210
> > 221
223
04 or Sq
W CD Z t4 Jasper 225 225
4
170 30 E Snd..., Aide 229 232_�, 234
is Here 230
217
M :L— 219 303
160 ei) a 239
233
06 242 306
Sunset 314
Al 315
250 32
z 3N c, 318 317
402
324 263
410
LU 5 405
a) 267 420 Beck's
NWIldlife�: ms 272 w
> 271
33L
Cbu 424
— - - - - - - ROW6 341 5 Bank
32 43
404 2 AL --
NUT s r
403
3
414 412 410
409
420
511
424 n 515
417
Edmonds Park 0
7
405 o
C
0
P,
SO
0
ZI
0.6Y
CD
CB Type 1
GE 45.17
1E E 43.47 8" CP
52 12" CP
IE NW 53. 1" �PCJ
12
BTM 42.47
0
U)
Set Rebar & Cap I
LS 30581 (t)p)"/1
65.dO
04
P
Asphalt Driveway (R
*:§j�0,0"/ E, / A /
LWo-oct1-Fenc;-u---r-u-1
�0 1 13.7'
13'
House #343
40.2' 21.9 2'
0
Set Rebar & Ta;ck asis
LS 30581 (typ)
Ct
TBM
Cf- AR A7
8" CP SD SD
9,
- - - - - - - - - - - - - - - J
W V
9D
0
-8
8.9,
9
28.5'
EMli-.
House #301
f
ui FF 53.4216
0
C14 2.0� Eaves C14
'I
28.2'
Z
---------
L4- N
65.00'
0
ncrbte�Wolk`
CB Type 1
GE 52.19
IE S 50.94 6" CP
BTM 49.39
ch
I (n
.b\
to
ewe
-7 2- G. 75'
Alf 5f
GAfO.3C 305" .417 RECEIV D
6713.76 5"-f A's -remvl Q",-%ST- SEP 1 .9 20.06 .
.E1Vr,LANCZ PE-4 714M. 6,v, zef�-. BUILDING DEPT.
La
MERIDIAN
ASSUMED
GRAPHIC SCALE W
-20 0 10 20 40 W
6mmm 6=" M
onsommom .
(IN FEET)
1 inch 20 ft.
LEGAL DESCRIPTION
-;C- C13 Type 1 House #325
/G-E52.59
(111 NE 50.54 8- CP
IE E 50.93 8" CP
'E SE 50.84 12" CP
IE W 50.59 8-
STM 49.99
16'
/-av�co k
SID -UGP 0 14
-G n
Found MIC. 1 3 Asphalt Street 14�1
Brass Disk wl �xi"
Down 0.5' r-13
10
C�
0
I
0
10
ss SS---1SS SS A r=SS
---ssl - I-- - - N 89*53000" E (Basis cxf Bearings)
G
Walnut Street
G�G �G Underground G- Gas G -G
\ \ \ \ \ \ \\\ Npon- cret-9 'gutter, (Ayp)
IE E 35.77
12"
CP
IE SE 40.27
8"
CP
IE SE 39.12
8"
CP
IE S 35.47
18"
CP
IE W 33.77
18"
CP
z
TFound MIC
Brass Disk wl 'X'
Down 0.7'
RECORDINO CERTIFICATE
Filed for record this -day of
20--at ----.M in Volume -of Surveys
on Page_, Records of SNOHOMISH County,
Washington at the request of BRENT EBLE
Auditor Deputy Auditor
G
THAT POR11ON OF SECTION 23, TOWNSHIP
27 NORTH,
RANGE 3 EAST, W.M., BEGINNING AT THE
SOUTHWEST
CORNER OF THE SOUTHEAST QUARTER OF
THE L
SOUTHEAST QUARTER OF THE SOUTHEAST
QUARTER ON
THE CENTERLINE OF 3RD STREET;
THENCE NORTH ON SAID CENTERLINE, 170
FEET;
THENCE EAST 30 FEET TO THE POINT OF
BEGINNING;
THENCE CONTINUING EAST 130 FEET;
THENCE NORTH 67.4 FEET;
THENCE WEST 130 FEET;
THENCE SOUTH 67.4 FEET TO. THE. POINT
OF BEGINNING;
EXCEPT THE WEST 65 FEET THEREOF;
SITUATE IN THE CITY OF EDMONDS, COUNTY OF
SNOHOMISH, STATE OF WASHINGTON.
TREE DESCRIPTIONS
ue Sortlbe�-'(Piceo punge
SURVEY NOTES
Found Surface Mon
2 3/4" Bross Disk
wl 'X', 0.3' below ACP
33�
IE W 39.18 12"
IE N 39.28 12"
IE S 41.93 12"
I SURVEYOWS CERTIFICATE
This map represents a survey made by me or
under my direction in conformance with the
requirements of the Survey Recording Act at
the request of SCL ENTERPRISES
in JUNE
2006.
C c
ertifficate umber 30581
INSTRUMENT USED: SOKKIA SET 5 EDM
METHOD USED: FIELD TRAVERSE
APPROXIMATE POINT ACCURACY: ±0.05
SURVEY MEETS OR EXCEEDS STATE STANDARDS PER WAC
332-130-090.
MONUMENTS SHOWN HEREON WERE VISITED ON JUNE 9,
'2006.
THE INFORMATION SHOWN ON THIS MAP REPRESENTS THE
RESULTS OF A SURVEY MADE ON THE INDICATED DATE
AND' . CAN ONLY BE CONSIDERED AS THE GENERAL
EXISTING CONDITION AT THAT TIME.
NO EASEMENTS, RESTRICTIONS OR RESERVATION OF
RECORD WHICH WOULD BE DISCLOSED BY A TITLE REPORT*
ARE SHOWN.
VERTICAL DATUM - NAVD 88
CONTOUR INTERVAL 2 FEET
BENCH MARK: POINT NAME: V-297 "Brass Disk in
Conc-Station mark is' a BM disk at Edmonds, along 5th
St between Main & Bell streets. Set vertically in W conc
wall of the Edmonds Museam, 0.5' N of the SW car of
the bldg. 48' E of the C/L of 5th S t & about 2'
higher than the ground." Elev: 69.840.
SURVEY IN THE:
S.E. 1/4, S.E. 1/4 SEC. 23 TWP. 27N., RGE. 3E., W.M.
MIW.
RECORWOFSURVEY
HMM
SCL. Enterprises
CHECKED:
SHEET
BLE
301 Walnut Street
OF
Edmonds, WA 98020
PROJECT;
06240
1
EMERALD LAND SURVEYINOw- INC.
DATE:
PO BOX 13694 MILL CREEK, WA 980.82 PH. (425) 359-7198
.6/15/06
k
n
LO
(0
0
0
0
Z
Z
0
_J
.U)
C
CL
Ld
_J
0
W
1_�
W
C
Ld
D
Z
Ld
I
LL
Q
SEWER NOTES:
i. Prior to backfillhig, all construction Inust be inspected and approved by the Engineering
Inspector. Call the Engineering inspection line 24 hours in advance at 425-771-0220,
extension 1326 to schedule an inspection. Side Sewer inspections are performed between
the hours of 8:30 a.m. and 3:30 p.m., Monday through Friday.
2. Side sewer installations shall be complete and ready for inspection at the time of the
scheduled inspection. If the work is not ready when inspected, a re -inspection fee will be
assessed and must be paid befor6 a re -inspection is scheduled.
3. A water or air test is required on the sewer line. Side sewers *shall be tested for visible
leakage b0fore backfllling by inserting a removable test plug at the lower end of the line
and filling the line with water to five feet above ground level at the highest point of the
sewer line. Prior to the scheduled test time, the test shall be on and ready at the time
of inspection. Air testing may be substituted and shall be done at 4 PSI, as prescribed in
APWA Standards (bleed off valves and gauges must be set up above ground for safety
reasons).
4. If the work or materials are not in accordance with the provisions of the Code and
adopted City Standards, the inspector shall notify the contractor/owner by posting a
written correction notice at the site. A copy of such notice shall be kept on file at the
City. If such deficiencies are not corrected within the time specified on the correction
notice and if, iti the opinion of the inspector, the work is deftimental to the public sewer
system, the City Engineer may order said deficiencies to be corrected. The actual cost of
such correction shall be chargeable to.the contractor/owner in the same marifier as the
City's service charge and shall place a lien upon the property serviced by the side sewer.
GENERAL SIDE SEWER NOTES:
• Prior. to --gn _g R_--of-w4y or -adjacent to a Publ c
y. excavation in the p b-fic-ri ht
place, call DIAL -A -DIG at 1400-424-5555. Allow forty-ei hours notice
to locate utilities.
• If available on file, information pertaining to sewer connections, stub location, depth and
main location can be obtained from the Engineering Division at City Hall.
• Outside drains, footing drains and/or downspouts shall not be conriected,to -the side sewer
system.
a� ar
6. A 6 inch cleariout with locking cast iron larriphole cover, per City st nd ds, shall be
installed at final grade at the property line and when located in asphalt or concrete
surfaces.
• A cleanout shall be provided for each change of 90 degrees of grade or alignment, unless
two 45 degree fittings are used, in which case fittings must be separated by a minimum of
three feet of pipe.
• In no case shall the distance between cleanouts exceed one hundred feet. A cleanout
shall be placed at each stack of house plumbing to provide access if the line ever requires
cleaning. All cleanouts shall be extended to within one foot of ground level. Cleariont
-covers must be set flush (extended to finished grade) with all concrete or asphalt
driveways, walkways and access roads.
.0 All installations requiring sewer grinder pumps or ejector systems must.have design
approval by the City Engineer prior to construction and must, be. included with the side
sewer application. See separate informational handouts. Approved backflow devices are
required if the elevation of the plumbing is below the elevation of the upstream manhole,
and must be tested prior to final inspectiom.
o Plumbing changes required by the side sewer construction, such as reversing the
plumbing under the building, require a separate Plumbing Permit. COhtadt a Permit
Coordinator at 425-771-0220, for more information.
0 Side sewer permits issued with building permits will expire with the mainbuilding
per�xdt. All other permits (i.e,., repairs, replacements) expire 60 days from the date of
issuance.
301 WALNUT S11
Vk
LEGAL DESCRIPTION:
(PROVIDED BY OTHERS)
VICINITY MAP
NOT TO SCALE
THAT PORTION OF SECTION 23, TOWNSHIP 27 NORTH,
RANGE 3 EAST, W.M., BEGINNING AT THE SOUTHWEST
CORNER OF THE SOUTHEAST QUARTER OF THE
SOUTHEAST QUARTER OF THE SOUTHEAST QUARTER ON
THE CENTERLINE OF 3RD STREET;
THENCE NORTH ON SAID CENTERLINE, 170 FEET;
THENCE EAST 30 FEET TO THE POINT OF BEGINNING;
THENCE CONTINUING EAST 130, FEET;
THENCE NORTH 67.4 FEET;
THENCE WEST 130 FEET;
THENCE SOUTH 67.4 FEET TO THE POINT OF BEGINNING;
EXCEPT THE WEST 65 FEET THEREOF;
SITUATE IN THE CITY OF EDMONDS, COUNTY OF
SNOHOMISH, STATE OF WASHINGTON.
S.E. -1/4, S.E. 1/4 SEC. 23 TWP. 27N., RGE. 3E., W.M.
SURVEY NOTES & DATUM:
(PROVIDED BY OTHERS)
MONUMENTS SHOWN HEREON WERE VISITED ON JUNE 9,
2006.
THE INFORMATION SHOWN ON THIS MAP REPRESENTS THE
RESULTS OF A SURVEY MADE ON THE INDICATED DATE
AND CAN ONLY BE CONSIDERED AS THE GENERAL
EXISTING CONDITION AT THAT TIME.
NO EASEMENTS, RESTRICTIONS OR RESERVATION OF
RECORD WHICH WOULD BE DISCLOSED BY A TITLE REPORT
ARE SHOWN.
VERTICAL DATUM — NAVID 88
CONTOUR INTERVAL — 2 FEET
BENCH MARK: POINT NAME: V-297 "Brass Disk in
Conc—Station mark is a BM disk at Edmonds, along 5th
St between Main & Bell streets. Set vertically in W conc
wall of the Edmonds Museam, 0.5' N of the SW car of
the bldg. 48' E of the C/L of 5th St & about 2'
higher than the ground." Elev: 69.840.
PROJECT INFORMATION:
OWNER /APPLICANT:
SHAUN LEISER
SCL ENTERPRISES LLC
17921 LINDEN AVENUE N.
SHORELINE, WA 98133
PH: 206-229-6038
ENGINEER: .
ERIK DAVIDO, P.E.
DAVIDO CONSULTING GROUP, INC.
15029.BOTHELL WAY N.E. SUITE 600
LAKE FOREST PARK, WA. 98155
PH: 206-523-0024
FAX: 206-523-1012
SURVEYOR:
BRENT EBLE, P.L.S.
EMERALD LAND SURVEYING, INC.
P.O. BOX 13694
MILL CREEK, WA 98082
PH: 425-359-7198
SHEET INDEX:
C01 — COVER SHEET
CO2 — SITE, GRADING & TESC PLAN
CO3 — DRAINAGE PLAN
C04 — UTILITY PLAN
C05 — DETAILS
ABBREVIATIONS:
CB CATCH BASIN
ESC EROSION & SEDIMENTATION CONTROL
FF FILTER FENCE
FG FINISH GRADE
FGTOER = FINISH GRADE AT TOE OF ROCKERY
FGTOPR = FINISH GRADE AT TOP OF ROCKERY
SD = STORM DRAIN
SDFM = STORM DRAIN FORCE MAIN
SS = SANITARY SEWER
SSCO = SANITARY SEWER CLEANOUT
SSMH = SANITARY SEWER MANHOLE
SSS = SANITARY SIDE SEWER
TOC = TOP OF CURB
TOP = TOP OF PAVEMENT
TYP = TYPICAL
W = WATER
WM = WATER METER
SEWER NOTES CONTINUED: -
In the event that the sewer main is broken while tapping, that section will be
replaced at the contractor's expense and shall be inspected by the Engineering
Inspector prior to backfilling.
o A toll -in Wye is required when connecting to six-inch diameter lateral lines.
0 When connecting to clay pipe, the contractor shall remove a section of pipe, install a
PVC tee with extensions and connect PVC to clay using Romac couplings.
e A manhole is required when connecting lines 8 inches or greater in size to sewer mains or
at bonds.
TRENCHING, BEDDING & BACKFILL
0 The contractor shall insure proper compaction around an pipe and connections, It is the
contractor's responsibility to obtain and follow City of Edmonds standard specifications
and requirements prior to construction.
a Side sewers shall not be installed at less than 2% nor greater than 100% grade Without
prior written approval by the City Engineer.
a Side sewers shall not be installed closer than 24 inches from a building at any point.
Cleanouts shall be installed on each plumbing line exiting the building (within 2 feet of
the building).
0 All p" e shall be laid with a minimum of 24" cover. At point in which sewer enters
ip
building, if 24". cover cannot be maintained and pipe is in driveable surface, pipe material
shall be constructed of ductile iron or schedule 80 PVC or equivalent.
a All pipe shall be laid on firm earth and bedded with granular sand per City standards.
Bedding in all other soils must be approved by the City Engineer. All trenches shall be
free of water at the time of inspection.
* All trenches deeper than four feet must either be shored or daylighted in accordance with
all Washington State Safety Regulations. The City of Edmonds will not inspect a side
sewer or main line installation until this'condition is met. The contractor and/or ownei is
also liable for shoring and conditions around a resident's property and any damages that
may occur in the installation of a side sewer associated with that property.
o Water services must be separated from. side sewers a minimum of ten feet horizontally
and 18" vertically. When it is necessary to --ross a side sewer over a water line, provide a
twenty foot long sleeve around the sewer service, centering the sleeve on the side sewer.
9 Boring will be allowed only when open cut trenching is not feasible due to . depth and
location. Glued joints are allowed only In boring situations.
WATER NOTES:
1. The water service pipe line shall be bedded on a firm, undisturbed base that is
smoothly graded and free of large materials. If materials for backfill are larger thanY2"
diameter rock, a proper sandy soil shall be on site to backfill to 2 inches above the
water pipe at time of inspection. If soil is disturbed, it shall be compacted to provide a
stable base.
2. The pipe depth shall be a minimum of 18 inches from finished grade to top of
service pipe and an 18 inch depth at the meter box.
3. When polyethylene pipe or other non traoeable pipe is used, it must be buried with
1 .2-gauge solid core tracer wire with vinyl coating. 'flie run must be continuous,
grounded at the meter and house and taped every 10 feet to the water pipe.
4. Polyethylene Pipe connections at the meter must be made with brass compression
fittings. In addition, brass fittings shall be used to connect sections of pipe together.
All connections shall be double -clamped with stainless steel clamps and shall be
secured in opposite directions
5. Proper pipe connection fittings to the water meter, for all other material shall
be approyed by the City prior to connection
5. Piping shall be flushed out and under pressure with no leaks at the time of
inspection.
6. The water service line shall not be buried with the sanitary sewer or drainage pipe.
a) Minimum horizontal separation between sewer and water shall be 10 feet.
b) Minimum vertical separation between sewer and water shall be 18 inches.
When the minimum 10 foot separation Is not possible, due to lack of space, the
waterline shall be placed on a solid shelf excavated at one side of the common trench
line 18" above the top of the sewerline and at least 18" from edge of waterline to edge
of sewer line (see figure 1 below). If the waterline must cross the sewer, it must be at
least 18" above the top of the sewer pipe at all points.
Water service line and all connections shall be inspected prior the backfill and the
preceding criteria must be met, or inspection will not be performed. Call the
Engineering Inspection line at 425-771-0220, Ext. 1326, 24 hours in advance to
schedule the required inspection. You may state your preference for morning or
aftemoon. Approved permit and/or job card must be on site at time of inspection.
f- f tJ 4N E E [-I I N G
0
0
V) C14
Z
W
Z
0 0
<
of
W L.LJ M
a� n- LLJ
U) 1:m_
Ld
L.Li LLJ
ry 0:�
0
0
W I
C)
0
6
Z
�D
Z
0
>
0 U
U 0
0
U
FEXPIRES 7/18/ C>-?
5�_ U-)
LO
WLO
W L0
01
LA_ ,
Ld N
M 1"t
V)6
�0
00
01
04
_J
_J
0
C14 Os
00
aN
0
C1
C)
<D
00
03
Ct
CN 44 C14
C,4
tn C)
C-4
C) ro
V)
I LLJ V-)
_J 5
0
:7
,.,00
V) X_ cy)
LIJ
(D
:2
F-
Ld
Lij
V) > <
F__ <
C)
:D Lu
LJJ
r
Z
Ui LLJ
Z
_J
< V)
W
X
W C) Z
�-- Z —
Z_ I
3;:
F_
UJ
>
L.13 I t1i
ry
D
07'
0
r)
_J
C) 0) _r
U) V)
<
o
W
Z
3:
Ld
0
0
W
1
PROJECT
MANAGER:
ED
DESIGNED
BY:
NMD
DRAWN
BY.
NMD
CHECKED
BY:
ED
SCALE: SCALE AS
SHOWN
.DATE: REV. SHEET
1
05/15/2007 OF
5
SHEET NUMeER
C01
5�D zoo 12A
(-/u
-?63 W AT
�(ku_,
RE, ua
f`14 .17 20�
4 J1
M - M E r., I
10 0 10 20
6mmi
SCALE IN FEET
GRADING QUANTITIES:
TOTAL SITE CUT: 156 CY
TOTAL SITE FILLL
0 CY
TOTAL NET CUT: 156 CY
GENERAL NOTES:
1. EXISTING SECTIONS OF CURB,
GUTTER & SIDEWALK TO BE REMOVED &
REPLACED AS REQUIRED BY CITY
INSPECTOR.
2. ALL LANDSCAPING ADJACENT TO ALLEY
SHALL BE LIMITED TO 3' IN MATURE
HEIGHT.
0)
Hf
wm
.. ......... 71
BOTTOM OF LOWEST
FOOTING ELEVATION 48.50'
EXISTING CONT (TYP)
IS11
AT
H EXISTING GRADE
MATCH EXISTING GRADE-
OWNER/CONTRACTOR IS RESPONSIBLE
FOR EROSION CONTROL AND DAMAGE
MATCH EXISTING GRADE
X-C 'X- X- X
X_ X_ X_ X_
FG 50.10'
F
'
X_ X_
FILTER FABRIC
SECURED TO 2' X 2'
14 GA. WIRE FABRIC
EQUAL
C)
2' X 2' WOOD OR
EQUIVALENT
0i
-111-1 1
1'rTW7,_I I I-
8'- 12'
%,D
PLACE 3/4'-1.5' WASHED GRAVEL IN
THE TRENCH AND ON BOTH SIDES OF
FILTER FABRIC FENCE ON THE SURFACE.
i m —
FFI M F
CONTRACTOR/DEVELOPER SHALL MAINTAIN AND REPLACE
STRAW BALES TO INSURE PROPER EROSION CONTROL.
sA ASPHALT CLASS B ftVL" 16-13e WV006b
SD so IF o
DRN (C S MIN. A-cJP
rs
RIM 49.45 .4 �QJO3
4
BOTTOM OFLOWEST 1! 4.07.
FG 50.82'
FOOTING ELEVATION 48.50
FG 52.06'
SSS .---4
sss
-__iNE
OVERHANG LI
!:: 1, "". 6" TRENCH DRAIN
ELEV 57.47' -, - .,
0) RIM = 49.45'
(A 2
INSTALL TEMPORARY
wo
BUILDINL, Tt
STORM DRAIN INLET
�o
PROTECTION
FF GARAGE: 149.47'
i � I
__/Y FG 52.06'
CONTRACTOR SHALL USE
V
FG 5 .82'
EXISTING DRIVEWAY FOR
4.1. 1
CONSTRUCTION ENTRANCE
C3
'X OR INSTALL NEW STABILIZED
CONSTRUCTION ENTRANCE
MATCH EXISTING GRADE
7_
-----------
r. Q�
'07 GE 52.59
("p T -
NNG
E 0. 93
.45
RIM 49
FILTER FABRIC SILT FENCE x
�C 0 2) z W U" IE SE 50.84. 12" C1, P
FG 50.82'
w
r .x .... 11 5(159 s"
<
V)
RIM 49.90, BOW 50.42' SW 52.17' 1311-1\4 49. 9 9
n LANDSCAPING SHALL
(J-1 Typr-:? I K
M MATCH EXISTING GRADE SD SD SD SD
LIMITED TO 3'
EL
7z-
IN HEIGHT
IE
EXTEND EXISTING
Conc,
............. ... ..... V�SIDEWALK TO ALLEY SW 52.95' 1�)
IF I\IW 1'7 1.-' �1')" ('17�t 8) 7 ......... ...... .. e�
I; ,
.... .......... ... ...
. ..... --------
... . ....... SW 50.32'--*** . ...... 7 --------- - M
(D 163"Ilvi el 1". -1-7 BOW 49.70' SIN 52.07'
0 SW 52.85'
0 ..............
04
()I 1p ----- ----- --- ------ om . ....... ....... ...... -- ----- SW 49.60'- m . .....
... .... ... .......... -------- ---------- -
---------- -
9 ....... U(3p ---------- - - 0 INSTALL TEMPORARY
TOC 49.50 0 PROPOSED
rB
STORM DRAIN INLET
TOP 49.00 MAILBOX
PROTECTION
....... ... LOCATION
..... ..... - _. 1 1 -02 ------
w IN Y,4 ... TOC 50.22 �C )vi
y/
w w G ....... ...
INSTALL TEMPORARY TOP 49.72' Asv)halt Sb
�A2 TOC 52.50' \\,rA 2
STORM DRAIN INLET �Cov
z INSTALL TEMPORARY
FOUIld 101C, 1XI TOP 52.00'
�Brass Di-sk vv PROTECTION A2
< Down 0.5
STORM DRAIN INLET �� I " _. I \ �o
PROTECTION �C 0 2) (p
----- ------- I ----- --
............... .. .....
..... ..... . ..... ....... QC -- -------- S-S
z
E �Ekjsii- De-cirincis)
ry
_1�s TOC 51.97"j,
TOP 51.47'
5�
0
'CjrOUnd
(J I I d rN (.1 S
SD
_� v
�� A�t
65
00'
I
RIM 49.90' 6" AREA DRAIN 1p". MATCH EXISTING GRADE
�2 INSTALL TEMPORARY A2
� INSTALL TEMPORARY
r
(A I TOC 51.32' TOC 52.56'
STORM DRAIN INLET STORM DRAIN INLET FG 52.06'
PROTECTION PROTECTION 7 �FG 50.82'
XI
1
C C
11' V
BOTTOM OF LOWEST
FOOTING ELEVATION 48.50'
MATCH EXISTING GRADE
0
CD
15"0 DETENTION TANK '1771
z
PROPOSED CONTOUR
rA 1� INSTALL APPROX. 125 LF
0)
G- - - -------- ...............
---------- - ------- ---- ....... - ------- ...... G
Q)
I
G v o
0
V) 60" ssmi-i
CL
Pirn 4-5.:37
c:
U-i
IF: E *35.7'7
12"
CP
0
1E SE 40.'?."7
8"
c,P
8"
CP
IE S, _.1)!5.47
I(B"
CP
11--" w
cr�
w
z
w
0
ILL
0
AFTER CONSTRUCTION ENTRANCE
IS NO LONGER NEEDED, CONTRACTOR-..
...... SHALL REMOVE THE EXISTING DRIVEWAY ------ - ----------- -------- --- ...........
CURB -CUT AND. REPLACE IT WITH n..
STANDARD CURB, GUTTER AND SIDEWALK
PER CITY STANDARD DETAILS E2.13 & E2.8.
C�j
TESC PLAN EXISTING CONT (TYP)
SCALE AS SHOWN
_5 _5 8. J
G, . ..... -
60" SSMI-I
. ......
R)irn 53,4)3
IE W 39.18 12"
I[- N 39.28, -12"
I F S, 41. 9 3 12"
FILTER FABRIC MATERIAL IN
CONTINOUS ROLLS. USE STAPLES
OR WIRE RINGS TO ATTACH
FABRIC TO WIRE,
I ff-_= WIRE MESH SUPPORT FEN�E
TO SUPPORT FILTER FA��IC.
... TT-= =M;�j�'fj U=M=rr'
T
- - - - - - - - - - -
BURY BOTTOM OF FILTER
MATERIAL 8' TO 12'
6' MAX,
u
L
2' X 2' WOOD POSTS OR
EQUIVALENT
FILTER FABRIC SILT FENCE
PER CITY OF EDMONDS STD PLAN E1.1
NOT TO SCALE
7/8' WASHED ROCK
FILTER SOC
OVER FLOW
f-DATC
MAXIMUM DRIVEINAY SLOPE
ALLOWED 10/9
CATCH BASIN
�s
PLACE FILTER
SOCK BETWEEN FRAME
AND GRA
TE, PLACE 7/8" WASHED GRAVEL
3-4 INCHES HIGH AROUND CATCH BASIN
TO FILTER WATER.
STRAW BALES MAY BE USED IN' CERTAIN CIRCUMSTANCES (SEE DETAIL E111)
UPON APPROVAL OF CITY ENGINEER OR HIS/HER REPRESENTATIVE.
THIS APPLICATION SHALL BE MAINTAINED AT ALL TIMES DURING
CONTRUCTION PERIOD.
EXI
CATCH BASIN INLET PROTECTION
PER CITY OF EDMONDS STD PLAN E1.3 �A2
e
NOTTO SCALE
�cold
PROPOSED MAILBOX
CITY OF EDMONDS.STD PLAN E8.7 rB
NOT TO SCALE
�c 0
SUPPORT BUT
.12" DIA IRON
FED WOODEN POST
'U"il ;'_-1J;I INEERI'i\113
7
0
0
C14
_c
z :2 >_
0 0 Q�
(n u <
D
> Cf ry
W UJ M
O� cl- uj
Li_
V)
z 0
Lu
2 >
vi Lu
5;
ui w
Q� 0�
0
w I
<
4
0
z
u
0
u
0
u
FEXPIRES 7/18/ C>
0
0
�_Io
to
wto
MLO
o
U-
w CINI
m `1
_j
X
0
c;
%0
00
ON
c>e
o 2 c,
M 0 cr;
44 cq
a%
eq
kn C>
Z
<
z
0
LIJ
Z
0
u
'700
o)
w
>
V)
LLJ
V) <
<
ip
D W
Z
r1l LLJ Ljj
z
I -
< 0
0
W r) Z
z
z
I Li
rill
:D
0 Z
a
<
0)
<
o
w
V)
w
w
z
0
0
PROJECT
MANAGER:
ED
DESIGNED
BY:
NIVID
DRAWN
BY:
NIVID
CHECKED
BY:
ED
SCALE:
SCALE
AS
SHOWN
DATE:
R EV.
SHEET
2
05/15/2007
OF
5
SHEET NUMBER
CO2
RIGHT-OF-WAY CON'STRUCTION PERMIT
AND INSPECTION REQUIRED
RES' 0
14",S 17 2007
C'.11J&DING
1_yffiMn
MA vi . . . ....... .... ...
yl
Type 1
(L
Cl -115. 1
0 4. 15, 47 �'3 CI
Lo I"*.- NW 43.52 1'2" k"I')
(D
0 C-37'M .1-2.47
$Z1 IF,
8 c P
. ........ . . LjGP
0)
V1 w W
0 . .....
z Found Ml('.', 1 '31A."
Di%,,I< w/ 'X
a [)awrl
z
my
ry
cl)
_j
< G
G v
0
Go" SSMF..l
cn
cf)
Q) Rlirn 4!5.37
c
w I I IE E 112"
_j
I E S E Il- 0. 2 7 8" C P
(n
c)
c
Q) IL SE �59.12 8"
IE S 35.47 18" Cl--'
I E W �3. 7 7 '18 CV-:)
Ld
z
w
_j
46 LF 6" PVC SID @ 1.00%
5,
of 6" AREA DRAIN
65.0
RIM 49.45
6" IE 48 49'
CB#1 TYPE 1
,RIM 49.90'
67 IE (E) 48.03'
15" IE (S) 47.53' so IW OJ4.5% So
DRN
F
4" DOWN SPOUT
TIGHTLINE @ 2.00%
M
IN. (TYP)
sss 7
50 LF 15"0 DETENTION
41
TANK @ 0.50%, MATERIAL 17 Fe
PER CITY STANDARDS
BUILDIN A:
z
4" PVC PERIMETER v FF GARAGEi 9,47'
DliiVEWA)
FOOTING DRAIN (TYP)
36 LF 6" TRENCH DRAIN
RIM 49.45'
CB#2 TYPE 1
6" IE 48.95'
�1. 11 1 dl
W/FLOW CONTROL TEE .. ..... .........
E
RIM 49.40'
Z.
SPOUT
I I . >
�D 4" 1 E (E) 47.82' TIGHTLINE @ 2.00
rC 6" OVERFLOW 48.78' 4" DOWN %
15" TANK IE (N) 47.28' M I N (TYP)
'�\Q�C 0 5)
6 " I E (S) 47.28'
NNQ�_' NK
-- ------------- ------
ORIFICE ELEVATION 45.28'
ORIFICE SIZE: 5
/8't 4" IE 49.00' 8," ('F-I
12 LF 4" PVC 'I
F
.BOTTOM OF CB 43.28' 5
SD @ 2.00% cp
CONNECT 4" FOOTING 47 LF 4" PVC 1[ -')0. 59 8'
/1. 9. 9 9
_j SID @ 2.00%
DRAIN TO 6" SID 4" IE 48.76'
CONTRACTOR SHALL REPLACE so SD so so
EXISTING SIDEWALK IN —KIND
It:
C on �A/ (I I k
- --------- ............. .. ....
.......... ...
V Ul
("tip
m - ------------------ ------
12 LF 6" PVC SID @ 1.00% -----
. ... ....... ';D
. ...... --- ............ . ....
SI)
---------- ------- -- --- ------ -- .. ........
..........
CB#3 TYPE 1
.. ... ... ..
RIM 49.11'
------ - . . . . . I . A yi w
_'z �" :.:l %
. �%j
6" IE (N) 47.16'-
8" IE (E) 47.16' Sh I:
8'! IE (W) 47.06'
Clp
S"S - -------- s
:. '_ ______________ 4-
8 9'5 �' N 0 " E (B a s I s o f 0 e a r i n a s)
U)
G' a s G
G--- ----- _ ......... . G
re C,
Conc .(�Jjttqt
........... . ..... ---- - ------- ------- ..... .. .......... -------------
vi I - W
G
60" SSMI-I
Rin-i 53.48
IE W 39-18 '12"
IE N 39.28 '12"
Ill- -S 11-1.93 '12"
60. 00'
GARAGE CEIL
ELEVATION 5
50.00'
GARAGE FF
40.00'
Ld
I
_j
WALNUT ST.
LEGEND:
EPERVIOUS IMPERVIOUS
LAND COVER CALCS:
IMPERVIOUS SURFACE:
BLDG 1: 1,920 SQ. FT.
DRIVEWAY: 497 SQ. FT.
SIDEWALKS: 81 SQ. FT.
TOTAL: 2,498 SQ. FT.
TOTAL AREA: 4,355 SQ. Fr.
TOTAL IMPERVIOUS SURFACE: 2,498 SQ. FT.
TOTAL PERVIOUS SURFACE: 1,857 SQ. FT.
TOTAL POLLUTION GENERATING IMPERVIOUS SURFACES:
4 9 7 S Q. FT,
NOTE:
DETENTION AND FLOW CONTROL SIZED USING THE CITY
OF EDMONDS STORMWATER MANAGEMENT & EROSION
AND SEDIMENTATION CONTROL STANDARD #E72.
TABLE 1 — DETENTION PIPE SIZE
2,500 SQ. FT. = 50 LF 15"0 DETENTION TANK
TABLE 2 — OUTLET ORIFICE SIZE
2,500 SQ. FT. -_`_ 5/8"0 ORIFICE
TABLE 3 — RECTANGULAR CATCH BASIN REQ.
<18" = 20" MAX KNOCKOUT — CB TYPE 1
DETENTION TANK CALICS rC
40'
70.00 - - --- ----------- ---- -----
7.19' VERTItAL CURVE
x
< 0 :Hl -H :H
Lij n N
m �l C�
0 _j N
_j Lf)
ING >
.47' ---1
. ........... .
f4.
-H
4 1 9. 7' 0
c� LLj
Lr) _j
z 0 _j
< ILL <
----------- - ---------- —
-Lo
z
Lli a) _j
Of
(c) 0:�
30. 00'
40'
30'
20'
10'
30, 20' 10,
op
1 70.00'
40. 00'
0
or
30.00'
or
DRIVEWAY CROSS SECTION cs
DRAINAGE PLAN
Old
SCALE AS SHOWN
',V."
CEPTABLE TIGHTLINE
MATERIAL
Wil 35
BCH 40
N - 12
F810 HANCOR
[Y'(
on, n-l"
0
0
Z
Z
0 0
<
D
> ry ry
W L.Lj M
n Ld
LL_
V)
z 0
Ld
2 >
V, Ld
> C-)
ui Ljj
()� m
r)
m :2
z
0
w I
< C14
a I
0
I
u
0
�D
q
cd
z
0
u
0
U 0
0
u
4
FEERES 7/18/ 0?
L_j 1
C14 -
" CN
cf) cf)
00
CN
0 d4
12D
10
A
4)
ID
C)
00
o
Im 0
cl, P-1 cl
N tr)
CD 1 �16
C)
cl
n
V)
C)
Lj
Z)
r)
';7
z
z 00
Lli cy)
Ld >
V) <
<
_j
(L
D Ld
z
LAJ
w Lj
<
Ld C) Z
I- z
Z
3;:
z
Ld I Lli
W
0 Z
<
cr
_j 0
1
0
0 _r
cy) (f)
<
o
w
w )
z
0
0
PROJECT
MANAGER:
ED
DESIGNED
BY:
NMD
DRAWN
BY:
NMD
CHECKED
BY:
ED
SCALE:
SCALE
AS
SHOWN
DATE:
REV.
SHEET
.3
05/15/2007
OF
5
SHEET NUMBER
CO3
hA*i 17 2007
M,Lrti'l�&J00
04FITMENT
I
1 ' T E EXISTING SANITARY Sl��WER
LATIE L WILL NEED TO,,�V'D BY THE
W
CITY S BLIC �O DEPARTMENT TO
E E XSTING SAN I
L W' LL NEED '
Ir
"S BL C Wo
DETERMIN T ONDITION OF THE
EXISTING AND TO GAIN APPROVAL
TO R SE I, I F PU
1117 PUBLIC WORKS
5—ETEPMINF'--, THAT THE EXISTING LATERAL
CANNOT BE RE -USED THEN THE
CONTRACTOR SHALL REPLACE THE
EXISTING LINE FROM THE SEWER MAIN TO
?at.k(- WO%V4' M-5 ppMINW
LAIWL� AtU, igg.,-
ael,'o .40 V-g, fvtoo�j
I
CONTRACTOR SHALL CA� THE EXISTING
WATER SERVICE AT THE MAIN & ABANDON
IN PLACE THE EXISTING WATER METER
& SERVICE.
Y yi IN
,
V)
1 E 1:7 4 47
Lo
0 07M 42.47
0
C,4
oilp 0HP .... ....... QtW'
Ell' c 1`1
0)
yl..........
0 --------------
0
z Found Ml(, I APPROX. LOCATION
�i " v EXISTING M
--k .443-ross, Disk ,,Y/
cr_
z
<
cr_
0
Cl
cy)
0
G
.:;v
0 c�
6
ssmH
------ - ------
Rim 4 5.,'5 7
w I E E 3 5. 7 _7 12" CP
_j
U
L' '-,;E 40.�27 d""' (,I P
c;
SE "_5
I E S 3f,5. d- 7 18 CP
I I.]. . I W 3,"), 7 7 1 P
w
D
z
w 0
LL
_ kIll,
0HP
65.00'
21 LF 1 1/2" PE
WATER SERVICE
1 1/2" IRRIGATION STUB
It35'(*W BACKFLOW PREVENTOR
I—'
5, 0
SD SD -IW O.M.,T4 SD
r ----------- L
11 LF 4" PVC
SSS @ 2.00%
4" SSS 'STUB
4" IE 47.50'
4" SSS STUB
4" IE 47.50'
BUILDIN
z
Ei 9.47
FF GARAG
0
4
0 z
M
Ia.. O.H . ....
7
21 LF 1 112" PE
WATER SERVICE
�q
4" D-OWN SPOUT
TIGHTLINE @ 2.00%
MIN. (TYP)
<1
4" IE 49.00'
1 6" SSSCO (E
RIM 51.00'
6" IE 47.28'
6"X4" WYE
I jr. j �� I �
'I'll Pat M4 m*w
I r) I C' P" Mlr� nr--nUi e
SSS @ 2.00% MIN.
CONTRACTOR SHALL
(' F�
------ POTHOLE & VERIFY
I:_ NY
LOCATION & DEPTH
OF EXISTING SSS.
71'15 LF 4" PVC
SSS @ 2.00% MIN.
6" SSSCO W/ 12" LOCKING
C.I. LAMPHOLE COVER rE
RIM 51.75'
�C05
E 6" IE 47.10'±
4
Tm
I
9 LF 1 1/2" PE $13 SD
IRRIGATION SERVICE
J_
_0
t�)SD
.. ........ .......
... .. ... Ai .......
.. .......... .. ....
F. I
j V
G R=;;Z-q NEW 3/4"
I'M
L
. . .......
WATER METER" ------------- �A
... .......... ....... . . ...... ........ .... ......
. .... ....
. .. ........
.. .. ......
"ONO L ......... ... A.
ee _Ap"L� w4m* 50cluo . —I. j,""" G
ONTRACTOR SHALL REPLACE . . . . . ......... 4F;;;A(_L NEW 3/4"
EXISTING ROAD IN -KIND . .. ... WATER METER 6
.. . ....... ......
........ -------- ------- �C 0 5)
vi IN w 41
L C'
2" PE LENGTH TBD Z9 1ACL. NEW 3 4
WATER METER
C, P
..... ...... . . . .. .. ..... ... -- ----------
of Elenrings)
CO�R,R,ACTOR,59ALL TAP
INTO THE plcvv WATER MAIN
Al- TER I I lb
)PII`5IALLtL7-4;5T
vibow _WvM -WpW uirn4- 0\
cr)
Uriderground G, o �3
- ---------- ------------------- -- - G
C.(.)nci*e'.Gu-lA , -t �Jvp)_-.
- ----------
...... ...... ....... --
UTILITY PLAN
SCALE AS SHOWN
C 13 "ll'ype.
I F, Fl '5 0.
i I' E-,: 5().9.3 8" CP
5 0. S 4 12 " C' f
H I' M A q. Y 9
Ccmc. wolk
3.)8.73'
G
60?'
Riin 53,48
IE W 39.18 12"
IE N 59.28 12"
IE S 41,93 12"
0HPI— ol ip __.____ 01-1
W yl
WATER & SEWER
INSPECTIONS REM.
CALL 425-771-0220 EXT. 1320
BY
�:, I "At L
jm,_:�M M
1. mez.,
0
0
V)
Z
w r-
Z
0 0 ry
<
D
> ry ry
W LLJ M
CL LLI
LL_
V)
w
>
V, w
> 0
w w
ch ry
a3
w I
�— r-,
<
0
I
0
z
0
u
0
U 0
u
4
LLJ
z 00
UJI 0)
UJI >
<
rill Ld Lij
Uj LD Z
I— z
Z —
LLj _J Ld
ry
0
0)
r�_
Ir—
M
0
06t3
>-C)g
<00
0 1 zo
c*4 0
La
< a
d Z
r!I
cl%
"t cl)
0 e4 cl)
0
C)
00
0
C,4
c,
C14
0 z
M <
0 _j
D Lli CL
z
-j
< V) F—
F-
o
w
w )
z
3:
0
0
af
PROJECT
MANAGER.
ED
DESIGNED
BY:
NMD
DRAWN
BY:
NMD
CHECKED
BY:
ED
SCALE:
SCALE
AS
SHOWN
DATE:
REV.
SHEET
4
05/15/2007
OF
5
SHEET NUMBER
C04
f`iAY 17 2067
l$UlL[)lf\IC, E);7.pAF:rrME:
LO
(0
0
0
rl) I
0
z
rK
z
0
-i
0
An
C
CL
c
uj
-i
m
:2
Z)
z
W
-i
LL
NOTE:
TIGHTLINE AND DETENTION SYSTEM INSPECTION
REQUIRED BEFORE BACKFILLING
m,
af Ui
0 z
_j
`*'�ROOF GUTTER
0
4' MIN. PVC STORM PIPE
1 10' MIN. �'(TIGHTLINE)
5z W ' CLEARANCE
cl-
a_ 4' MIN, OUTFLOW PIPE TO APPROVED
STORM COLLECTION POINT
<REFER TO DWG 51 FOR
APPROVED COLLECTION POINTS)
CONTROL CATCH BASIN
DETENTION PIPE
DRAINAGE TIGHTLINE FROM HOUSE CAN
CONNECT TO EITHER OR BOTH CATCH BASINS.
FINISHED GRADE
TO APPROVED
q=.5% =T01-0=7-SLOP=E COLLECTION POINT
V MINIMUM
DETENTION PIPE LENGTH COINTROL
CATCH BASIN
F (REFER TO: TABLE OF
STD RESIDENTIAL DETENTION
SYSTEM SIZES FOR PROPER SIZE)
CONTROL CB I
0 LL-
wo
x
0
Wom
Lu 0
m z
l'— 0
5:2 0
0 Ld
0� M
N 0 T E:
DEVELOPMENT EXCEEDING 5,00b SQUARE FEET OF IMPERVIOUS SURFACE MUST HAVE !HE
DRAINAGE PLAN PREPARED AND STAMPED BY A LICENSED CIVIL ENGINEER. ANY PLAN
FOR A PROJECT LOCATED IN A CRITICAL DRAINAGE AREA, ENVIRONMENTAL SENSITIVE AREA, OR
A SITE PRESENTING SPECIAL PROBLEMS, MUST BE PREPARED BY A LICENSED CIVIL ENGINEER,
REGARDLESS OF THE IMPERVIOUS SURFACE ON THAT SITE. ALL OTHER DEVELOPMENTS
NOT EXCEEDING 5,000 SQUARE FEET OF IMPERVIOUS SURFACE MAY USE STANDARD PLANS.
STA NDARD RESIDENTIAL STORM DRAIN SYSTEM D
PER CITY OF EDMONDS STD PLAN E5.1 t,,�
NOT TO SCALE kro7'1
(FOR FUTURE DEVELOPMENT)
PLACE 2X4 AT END OF SIDE SEWER STUB AND CUT TO LENGTH TO
INSURE 3 FEET EXTENDS ABOVE GRADE. PAINT TOP 18 INCHES WHITE.
IN 3 INCH HIGH LETTERS STENCIL THE NUMBER OF EVEN FEET FROM
GROUND ELEVATION TO THE SEWER STUB INVERT.
8 GAUGE WIRE TO BE DOUBLE WRAPPED AROUND PIPE AND 2X4
STAKE AT OR ABOVE FINISHED GRADE.
z CASTIRON LOCKING LID
LAMPHOLE COVER
(EAST JORDAN IRON WORKS CO.)
Ld (MODEL #: 00366108)
12-
0
ry
n
Ld
z
cr-
ow 6" WYE AND 45' BEND
- I a-
Lo 0
ry 6" LATERAL RUN TO HAVE 6" TEE
n
SLOPE OF 2% MIN. TO
50% MAX. POSSIBLE
SEWER MAIN
LOCATION
RUBBER JOINT BISCUIT I PLUG OR CONNECTION AT
OTHER APPROVED WATERTIGHT PLUG MAIN SHALL BE
AT 45* ANGLE
OR GREATER
N 0 T E: POSSIBLE
1 . WHEN TAPPING INTO EXISTING MAIN SEWER MAIN
AN INSERTA—TEE SHALL BE USED. 22.5* OR LOCATION
PLACEMENT OF TEE SHALL DEPEND 45* BEND
ON DEPTH OF SEWER MAIN. AS A
MINIMUM, THE TEE SHALL BE PLACED
AT A 45 DEGREE ANGLE.
2. IF CONNECTING SIDE SEWER TO EXIST
CONCRETE LATERAL, A CONCRETE/PVC ADAPTER
SHALL BE USED AND SECURED PER MFGR'S INSTRUCTIONS.
W
z
RESIDENCE
10
Q�
LEANOUT WITH 45*
Lc BEND AND CAP
NOT TO EXCEED 100' BETWEEN
CLEAN OUTS
CLEANOUT(WYE WITH CAP
AND LOCKING LAMPHOLE COVER)
12'+/-
WATER TIGHT CAP
RISER
4' OR 6' SIDE SEWER
GENERAL CLEANOUT DETAIL
6' RISER
ASPHALT SURFACE
12" PVCZ
SLEEVE
6" RISER
z
:2
Of
Ld
V)
0
0 If —Z
00--l-i
6' WYE AND 45
AND 1/8 BEN]
LOCKING LAMPHOLE COVER
12" MIN.
6" CITY STUB
4' OR 6' SIDE SEWER—J
CLEAN OUT DETAIL AT PROPERTY LINE
PVC SLEEVE
PVC CAP
TYPICAL CLEANOUT UNDER ASPHALT
OR CONCRETE
THIN ki)
STEEL .
C.I. OR D.I.P.
12" LOCKING LAMPHOLE COVER
(EAST JORDAN IRON'WORKS CO.)
(MODEL #: 00366108)
NOTE:
SIDE SEWER JOINTS SHALL BE
GASKETED
SANITARY SEWER CLEANOUT
PER CITY OF EDMONDS STID PLAN E6.2 rE
NOT TO SCALE �c 0
GROUND/ROADWAY
NOTE, ALL FITTINGS SHALL BE BRASS.
IF USING 1-112' METER, ALL PARTS
SHALL BE 1-112' EXCEPT THE 2' WEDGE
GATE VALVE WITH BRASS BUSHINGS,
GROUND/ROADWAY
W
z
NOTEi SERVICE TAP TO MAIN SHALL BE ANGLED AND NOT EXCEED 22 DEGREES
1) 21 CP THREAD) DOUBLE STRAP SADDLE EQUAL TO ROMAC
STYLE 202 IS REQUIRED REGARDLESS OF PIPE MATERIAL
2) 21 BRASS CORP. CC X MIPT.
3) 2- 2' 13RASS STREET ELLS FOR SWING JOINT
4) IPS POLY HI-MOL PIPE (160 PSI) DRISSCO PIPE. CONNECTION TO MAIN
SHALL BE 1-1/2' CORPS AND SADDLE WITH FORD FEMALE IRON PIPE
SIZE PACK JOINT FITTING,
5) 12 GAUGE SOLID CORE WIRE (TRACE WIRE). STRIP PLASTIC AND
WRAP AROUND BRASS AT BOTH ENDS,
6) 2' STAINLESS STEEL STIFFENER AND 2' MIPT X IPS PAC.JOINT
7) BALL VALVE CRON PIPE SIZE) CURB STOP,
8) BACK SIDE OF METER BOX SHALL BE SET AT THE PROPERTY LINE,
NOTE, (METER 13OXES SHALL NOT BE PLACED IN DRIVEWAY AREAS).
9) 2' BRASS 90* BEND
10) WATER METER- TO BE SUPPLIED BY THE CITY
11) 2' METER SETTER WITH HIGH BYPASS EQUAL TO FORD DRAWING
#A-95147-01, VERT, IN, VERT, OUT, FLANGED BALL VALVE
WITH LOCK WINGS,
12) STACK 2 METER BOXES, MID STATE PLASTIC METER BOXES
<MS 17 X 30 X 12), WITH MS 17 X 12 DUCTILE LID WITH READER.
PLACE BACKOF BOX AT PROPERTY LINE,
13) BRASS NIPPLE
14) 2' THREADED BRASS NIPPLE (12' LONG)
15) SCHEDULE 40 2' RVC CAV, REMOVED WHEN CONNECTION MADE
TO CUSTOMER LINE,
16) 4' X 4' X 8' CONCRETE BLOCK SUPPORTS.
17) 2' RESILIENT WEDGE GATE VALVE (F.I.P. X F.LPA ULFM APPROVED,
FUSE BONDED EPDXY COATEb BODY AND BONNET,WEDGE FULLY
ENCAPSULATED WITH RUBBER AND WITH 2' AWWA OPERATING
NUT. EQUALTO CLOW F-6103,
18) 2-PIECE VALVE BOX, TOP SECTION TO BE RICH 940 STYLE
18' WITH REGULAR BASE SECTION, LENGTH TO FIT.
TYPICAL SEWER LATERAL 1 1/2" TO 2" WATER SERVICE
PER CITY OF EDMONDS STD PLAN E6.4 KT� PER CITY OF EDMONDS STID PLAN E7.6.1 G
NOT TO SCALE �C 0 4) NOT TO SCALE \"c 0
t"i i� I'! i -;' V r:
0
0
0
Z
LLI r-
z
0 0 ry
c) <
>
W LLJ M
[if 0_ LLI
LL-
0
z 0
Ld
0 >
uj
u
Ld Ld
cr W
L -j
- 1 2:
W
< c'
0 1
0
z
0
�D
Cu
z
0
u >
0
U o
0
u
4
1EXPIRES 7/18/0-'?
x
0 Lu
>-LO%
LO
LAJ Lr) cn
moz
0
0 1 r-
LL- It
LLJ C14
(no
>-og
< 00
min
cq C%
ON
0 mm
C>
0
tf)
00
cd
2' 1>
0 C�
M 0 en
44 C14
C)
kn C)
(14
Q z ro
lv�
Llj
D
r")
Z
z 00
V) LLJ Cr)
V) 0
Lli
(/-) > <
ry <
m
Z) LLJ
z
Lij Lij
W r-) Z
< F-
3;: Ld
F- z
z—
UJI
Ljj -J
cr
**, 0
o Z
1
c) -r
(f) cy) V)
<
0
W
W)
z
3:
0
0
0�
a -
PROJECT
MANAGER.
ED
DESIGNED
BY:
NMD
DRAWN
BY:
NMD
CHECKED
BY:
ED
SCALE: SCALE AS
SHOWN
DATE: IREV. SHEET
5
05/15/2007 OF
5
1, "t 2
t,,'i,`,Y 17 2007
OF