465 ADMIRAL WAY BOAT LOFTF,ROM PORT OF EDMONDS 10.17.2010 13:43 P.
"Illy
0 F-1,
Post -it' Fax Note 7671
co /090t
EIrz, Dtot
CO.
Phone
F- 0
Fig 0
able 9 AlloWeather
4MI% 0% C
What this important sinew" tool can mean to you,
the professional Marine Contractor, Builder, Tradesman
-v Allow you to keep skilled labor through the year Enhance your ability to plan and budget
. main van enmo1v with new revulations for annually
i
marine waste containment
• Eliminate weather -caused back-ups and down
time. Enjoy 365 climate -controlled days a yeaT
• Improve overall repair results
• Significantly increase your revenues
• Permit accurate and reliable scheduling of jobs
and materials — with dependable deadlines
NN
Increase boat shop crew comfort, efficiency and
productivity
Give the owner more prime seasonal use of his
vessel due to all-weather repair capability
Be in full operation in your own encloged boat
shop four weeks after you order it
Tha 'Roll -Away'
A telescoping. d9uUq module rhop.
Dimensions: 24'x 24' x 70' Mly extended.
Vewd length depicted: 50'. Shelter requires only 35'ofyard
space when nested, or separalts into two 35'shope. Many sizes available.
Whaa OOM Shop$ @Rd stovqe sheltevs can mean to Ownemp Opwatm and
Managews al Boat YaM9 MaTinas and Dry Slarago FaCififts
• Excellent marketing tool to bring year around
repair business and revenue
• Speed up boat turn around rate with less
weather delays. Ideal for small boat yards and
do-it-yourselfers on tight schedules
• Gives small marine businesses in the incubation
stage an opportunity to develop
• With addition of a non -permeable ground cover
an immediate solution to growing environmental
concerns for containment of marine repair dust,
waste, spills and paint overspray is available
• Keep your haul -out equipment and personnel
producing revenue year around
• Designed and sized to fit the dimensions you
need for operation in your boat yard
• Presents an organized, professional appearance
to port patrons and the general public
• Temporary and portable, these structures create
no permanent, long term planning consequences
ROH 19 0,90F the Wag and go to WOM
V01MOO"um OUROCUTO%
These are portable, easily redeployable, require minimal
ground preparation and can be erected with unskilled labor.
Put on' wheels to move it around, or sling it from a crane. Its
modular design is easily enlarged and virtually maintenance
free. Translucent roofs give ample working light during the
day greatly reducing electrical needs
These are 20 - 30 mil tough, durable, 'coated" polyester vinyl
coverings with 10-20 years expected life. Tensioned over a
rugged, galvanized spring steel frameworkof adouble rib and
ground rail design to handle narrow widths and unusual
height requirements
Engineered to withstand snow loads of min 25 p.sf , temps
from minus 60 to 140, wind loads of 70 m.p.h. and more if
properly anchored. They are fire resistant, self -extinguishing,
UV resistant and r�s_ist mildew and most chemicals. E
How has owning a
save Shop affeded
your business?
'I've Aad my building
over four years and it's paid'
for itself seueral times over.'
*it's time someone did
something for the du-19-
ycmrselfer.'
-We, already booking
johe for next ujinter.'
'I'd say the numbgr une
benefit is helping us meet the
repaired and renewable '
You can usually receive your she]
four weeks from your order date.
Current Uses
- Sandblasting
- Grinding
• Sanding
• Fiberglassing
• Welding
Fabrication
Stripping
Vessel storage
Varnishing
Painting
Boat shops and shelters typically cost between $4 and $9 per
square foot complete. Doors, end panels and other options are
extra.
I
Ground covers
End panels
Choice of fabric
Boat shops and storage shelters can be custom fabricated to your requirements or
choose from a selectiop of standard sizes
.7
Sfj
1ELL11re
Mast Shops
The ideal solution for painting, re -wiring, rigging
and general mast work. Protected fivm external
weather conditions and boat �ard activities
Boat Storage Shelters
Instant weather protection for the costly investment
most boats represent
Easy to erect, simpie to aismantie ana rewcate or store
when not in use
Available with open or closed sides, end coveru and
ground covers
In order to help you...
We need your answers to the tollowing questions tor any -application
What will your Satellite Shelter be used for?
Where will it be located on your site in relation to
other structures? What are the site dimensions?
Will it be put permanently in one spot, or used as a
mobile unit around your boat yard?
How many square feet of enclosed floor space is
To Order:
Contact Satellite Shelters Int'l. for a price quote for your
specific building needs. Terms for direct shipments are
50% with order, balance C.O.D. Normal production time
is four weeks. Orders for rush shipments, accepted
subject to plant scheduling. All orders are f.o.b. mfg
plant in Everett, Washington.
Warranty:
All sales of structures are subject to manufacturer's
warranty for material and workmanship. The steel
frame and fabric membrane covering have a ten year
warranty, and twenty year life expectancy. No
warranties expressed or implied are made by Satellite
Shelter% regarding merchantibility or quality.
needed? What inside clearances are. needed in length,
width and height?
• What type entries do you need?
• What type of "surface" will the shelter rest on?
• Any special requirements for wind or snow loads!
• How soon will you need your shelter?
Setup:
Complete erection instructions and procedures aTC
included with each Order. If needed.. Satellite Shelters
can provide supervisory personnel.
For more information,
Call or Write
S
S"ELTERS
Tr NIIT E�A �NATT 1 0 N A L
4531 SOUTH DISCOVERY ROAD
PORT TOWNSEND, WA 98M8
TEL.: (206) 379-9718 - FAX: (206) 385-7583
***END***
MEMORANDUM
DATE
_M�r�
REPORTED BY OF
SUBJECT
ADDRESS: 5- Ag ,A
CONCERNS/
HAZARDS:
FOLLOW-UP:
I.D.
0=1 .0
SIGNED
Al_.,T� I pJ AIW
4f L)
A�)� AT-L"./ OA/ 6 /A�J�/
SIGNED
City of Edmonds * Office of Fire Prevention
. . . . . . . . . . . . . . . . . . . . . . . ........ . . . . . . . . .
MEMORANDUM
TV -
DATE I.D.
REPORTED BY OF -7 7,57-z-/��
SUBJECT
ADDRESS:
CONCERNS/
HAZARDS:
FOLLOW-UP:
SIGNED
7r
0
S,16AJ
7c�o?.
1,,z5 4-1 C
SIGNED
City of Edmonds * Office of Fire P
n
CITY OF EDMONDS
CIVIC CENTER EDMONDS, WA 98020 - (206) 775-2525
FIRE DEPARTMENT
890 - 1 9 C�
April 24, 1991
Attn-Bob Yeager
Port of Edmonds
436 Admiral Way
Edmonds, WA 98020
Dear Bob,
LARRY S. NAUGHTEN
MAYOR
It has been noted that the post indicator valve for your
sprinkler system at the Anthony's Restaurant building is miss-
ing the security,lock. This lock is required to prevent tam-
pering with the fire sprinkler system at this location.
Please install a suitable lock at your earliest convenience.
#231 .
TV: be
If you have any questions, please call me at 775-2525,
Sincerely,
Tom VonSchuessler
Senior Inspector
e Incorporated August 11, 1890 e
Sister Cities International — Hekinan. Janan
iii'll'Ilml
336 ADMIRAL WAY--
IibMON6S -WASHINGTON 98020 o (206) 774-0549
December 7, 1990
Edmonds Fire Department
Attention: Gary McComas
City of Edmonds
Edmonds, WA 98020
Subject: Testing of the Dry Lines
During the last week of February 1990, the Port staff made a
hydro -test on the dry lines on all the floats. All of the valves
were checked and necessary repairs were made.
Bob Yeager
Maintenance Supervisor
BY/gs
RECEIVED
C 10 1990
EDMONDS FIRE DEM
CITY OF EDMONDS LARRY S. NALIGHTEN
CIVIC CENTER & EDMONDS. WA 98020 9 (206) 775-2525 MAYOR
FIRE DEPARTMENT.
, 890 . 194
October 20, 1988
Edmonds Marina, Inc.
458 Admiral Way
Edmonds, WA 98020
Dear Sir,
t
We are in the process of confirming that "leak detection" has
been installed on all flammable liquid dispensers in the City of
Edmonds. Please provide us with the most'durrent test results for
each pump in your system.
If it is determined that leak detection is not provided in your
system, one will be required based on the following code section:
The Uniform Fire Code, 1985 Edition, Sections 79.904(e) re-
quires that "each pump shall have installed on the discharge an
approved leak -detection device which will provide an indication
if the piping and dispensers are not essentially liquid tight".
If you have -..any questions, please call me at 775-2525, #233,
Monday through Friday.
GLM: be
Sincerely,
taGary
Fire Marshal
0 Incorporated August 11, 1890 0
Sister Cities International — Hekinan, Japan
January 7, 1988
MEMO TO: Duane Bowman
Assistant Planner
FROM: Gary L. McComas
Fire Marshal
SUBJECT: SM-4-87
The Fire Department is in favor of the proposal. It is long
overdue.
All design and construction must adhere to Uniform Fire Code,
Section 79.910. This section spells out requirements for
marine service stations.
GLM: be
;�Ole'�- OQ e"V�ls
WIN � M- - W�-- N I
= ft
CITY OF EDMONDS LARRY S. NAUGHTEN
CIVIC CENTER - EDMONDS. WASHINGTON 98020 a (206) 775-2525 MAYOR
FIRE DEPARTMENT
July 31, 1986
Mr. Michael Valiga, Manager
Port of Edmonds
336 Admiral Way
Edmonds, WA 98020
Dear Mr. Valiga,
Per our conversation, I have enclosed a CODY of the Uniform
Fire Code as it pertains to Marina Fire Prevention. The code.
require ' s that a permit is to be obtained prior to using a bar-
becue. It is the position of the Fire Department that no permit
will be issued for this type of activity within the confines of
the Port. The hazards associated with these open -flame devices
in close proximity to combustible fiberglass boat hulls.fueled
with flammable and combustible fuels is too severe to permit
their use.
If you require further information or if I could be of
assistance during discussion of this matter, don't hesitate to
call. As always,.we are concerned with Life Safety and Fire
Prevention.
Sincerely,
Gary L. McComas
Fire Marshal
GLM: be
Attachments
January 18, 1984
MEMO TO: Bruce Finke
Associate Planner
FROM: Gary L. McComas
Fire Marshal
SUBJECT: NEW OFFICE STRUCTURE FOR BOAT LOFT, INC.
456 ADMIRAL WAY (ADB-T--TTY—
After review, the fire department has the following requirement:
Provide one 2,A-10,B:C fire extinguisher and install
it near the 3' x 6'8" door.
JDW: be
January 10, 1984
MEMO TO: Hal Reeves
Building Official
FROM: Gary L. McComas
Fire Marshal
SUBJECT: NEW OFFICE BUILDING AT 465 ADMIRAL WAY
After review by the fire department, the only requirement
is for one fire extinguisher as indicated - minmum size is
2,A-10,B:C dry chemical type.
GLM: be
C4A
'000,
/V tz
zw�
CITY OF EDMONDS f HARVE H. HARRISON
CIVIC CENTER * EDMONDS, WASHINGTON 98020 * (206) 775-2525 MAYOR
FIRE DEPARTMENT
October 13, 1981
Port Commissioners
Port of Edmonds
426 Admiral Way
Edmonds, 14A 98020
Dear Port Commissioners:
We want to thank you for your cooperation in making_§qiT�q,
changes to im rove your fire protection. These improvements,
especially kZar) standpipes which have been installed, are greatly
appreciated. A pressure test was made on all docks and we found
that the problems we had noted have been corrected, and the
standpipe system is in service.
Now that the standpipes have been installed, we have one
final request. There needs to be a fire extinguisher located
near each standpipe connection. For an explanation of what we
need, please refer to the attached drawing.
If you have any questions, or if we can be of any assistance,
please contact this office by calling 775-2525, Ext. 234, between
the hours of 8 a.m. and 5 p.m., Monday through Friday.
Sincerely,
Stanley A. Olsen
Senior Fire Inspector
sr
a
Relocate the existing fire extinguishers so that they are in close proximity to the standpipe con-
nections. This will require the addition of one new fire extinguisher on each of the docks "A"
through "N". Locating the connections will be much easier in the event of an emergency once this
is done. (There is also a Code requirement that the fire extinguishers are to be located at each
required standpipe connection.)
The dots on docks "A" through "N" show the standpipe connection locations, along with indicating
where the fire extinguishers should be located. The other dots, shown at the bait dock ' the gas
dock, the launching area, the storage sheds, and the port building, are the present fire extin-
guisher locations.
10/81 sr
CITY OF EDMONDB HARVE H. HARRISON
MAYOR
CIVIC CENTER * EDMONDS, WASHINGTON 98020 9 (206) 775-2525
FIRE DEPARTMENT
May 15, 1981
Tenants of the Port of Edmonds
456 Admiral Way
Edmonds, WA 98020
Dear Tenants:
On a recent inspection, the Edmonds Fire Department found
many potential fire hazards concerning the cords being used
throughout the berths. The following are some of the require-
ments for electrical wiring and equipment for marinas and boat-
yards. Please read this carefully and make sure your own area
meets with the standards.
The Uniform Fire Code, Apendix F (concerning marinas),
#3(g), states that, "All electrical equipment in-
stalled and used must be in accordance with the
Electrical Code as it applies to wet, damp, and haz-
ardous locations".
The National Fire Code, Section 5-6.1, concerning
grou g, says, "Effective grounding of all non-
current carrying metal parts of the electrical system,
and provision of suitable connection of portable
equipment, including outlets provided for the con-
nection of shore power to vessels afloat, are of
utmost importance in marinas, boatyards, boat basins,
and similar establishments. This is due to the
exposure of electrical systems and equipment to water,
damp or wet earth, and to other grounded or partially
grounded conductive parts, and the consequent danger
to life and possibility of high sparking adjacent
to combustible materials".
The minimum size of wire for a shore power connection to be
used is 12 AWG, grounded, and twistlocked (if possible). The
approved types of cord are as follows: SJ, SJE, SJO, SJT, SO,
SE, SOO, ST, and any other cord which has been specifically ap-
proved for use in damp areas. These letters will be marked on
the cord, or they will be attached to the cord reel on a tag.
The Fire Department shall reinspect the premises in approxi-
mately 30 days. Your compliance is required. If you have any
Letter to Port of Edmonds Tenants
May 15, 1981
Page 2
questions, or if the Fire Department can be of any assistance,
please contact our office by calling 775-2525, Ext. 234, between
the hours of 8 a.m. and 5 p.m., Monday through Friday.
Sincerely,
Stanley A. Olsen
Senior Fire Inspector
sr
CUTY OF EDMONDS
CIVIC CENTER - EDMONDS, WASHINGTON 980.20 * (206) 775-2525
FIRE DEPARTMENT
May 15, 1981
Port of Edmonds Commissioners
Port of Edmonds
456 Admiral Way
Edmonds, Washington 98020
Dear Commissioners:
HARVE H. HARRISO N
MAYOR
The Edmonds Fire Department is always interested in im-
proving life safety and fire prevention practices. It was
noted on some previous inspections of the Port that the present
set-up regarding shore electrical power to boats in dock does
not meet the requirements of the National Electrical Code.
The National Electrical Code has specific requirements
regarding wiring in marinas and damp or wet areas. The Fire
Department strongly recommends that the good practices and
requirements of the National Electrical Code be complied with
in order to provide a reasonable degree of life safety and
reduce the potential of electrically caused fires.
The Fire Department understands that it may be difficult
at times to achieve immediate compliance in certain areas. We
realize that there would be expenses involved here, along with
0
being a project of considerable size and duration. Therefore,
the Fire Department would be very interested in working with you
to develope a timetable and discuss specific requirements.
Because of the investments at stake to both lives and
property, we are eager to work with you as soon as possible. A
spot on your agenda of a Port meeting at your earliest conven-
ence would be greatly appreciated. You can contact us by calling
775-2525, Ext. 233, between the hours of 8 a.m. and 5 p.m.,
Monday through Friday.
Sincerely,
Gary L. McComas
Fire Marshal
mp: sr
W &YZ. Cowltf
CITY OF EDMONDS HARVE H. HARRISON
CIVIC CENTER 9 EDMONDS. WASHINGTON 98020 - (206) 775-2525 MAYOR
FIRE DEPARTMENT 10/2_0p�79
1Jro -T7 0 I'J 0
7V 62�1 61
May 14, 1981
Tenants of the Port of Edmonds
456 Admiral Way
Edmonds, WA 98020
Dear Tenants:
On a recent inspection, the Edmonds Fire Department found
many potential fire hazards concerning the cords -being used
throughout the berths. The following are some of the require-
ments for electrical wiring and equipment for marinas. and boat-
yards. 'Please read this carefully and make sure your own'area
meets with the standards.
The Uniform Fire Code, Apendix F (concerning marinas),
#3(gT, states that, "All electrical equipment in-
stalled and used must be in accordance with the
Electrical Code as it applies to wet, damp, and -haz-
ardous locations".
The National Fire Code, Section 5-6.1, concerning
grounding, says,"KE-f—ective grounding of all non-
current carrying metal parts of the electrical system,
and.provision of suitable connection of portable
equipment, including outlets provided for the con-
nection of shore power to vessels afloat, are of
utmost importance in marinas, boatyards, boat basins,
and similar establishments. This is due to the
exposure of'electrical systems and equipment to water
damp or wet earth, and to other grounded or'partially'
grounded conductive parts, and the consequent danger
to life and possibility of high sparking adjacent
to combustible materials".
The minimum size of wire for a shore . power connection to be
used is 12 AWG, grounded,.and twistlocked. (if possible). The
approved types of cord are as follows: Si, SJE, SJO, SJT, SO,
SE, SOO, ST, and any other cord which has been specifically ap-
proved for use in damp areas. These letters will be marked on
the cord, or they will be attached to the cord reel on a tag.
The Fire Department shall reinspect the premises in approxi-
mately 30 days. Your compliance is required. If you have any
Letter -to Port of Edmonds Tenants
May 12, 1981
Page 2
questions, or if the Fire Department can be of any assistance,
please contact our office by calling 775-2525, Ext. 234, between
the hours of 8 a.m. and 5 p.m., Monday through Friday.
Sincerely, I
Stanely A. Olsen
Senior Fire Inspector
sr
I
4w
Jq
70-510 NATIONAL ELECTRICAL CODE
(c) 20 Ampere. 125-volt, 20-ampere, 2-pole, 3-wire, grounding type
for 115-volt systems.
Complete details of these configurations can be found in American National
Standard Dimensions of Caps. Plugs and Receptacles. ANSI C73.17-1972; ANSI
C73.13-1972; and C73.12-1972.
T
URU 'URINASiANU-IB--O—STN—A—R—D—S—,Z,,,
555-1. Scope. This article covers the installation of wiring and equip-
ment in the areas comprising fixed or floating piers, wharfs, docks, and
other areas in marinas, boatyards, boat basins, and similar establishments
that are used, or intended for use, for the purpose of repair, berthing,
launching, storage, or fucling of small craft and the moorage of floating
dwelling units.
See Part B for Floating Dwelling Units.
A. Marinas and Boatyards
555-2. Application of Other Articles. Wiring and equipment for mari-
nas and boatyards shall comply with this article and also with the applicable
provisions of other articles of this Code.
See notes following Sections 210-19(a) and 215-2(c) for voltage drop on
branch circuits and feeders respectively.
For disconnection of auxiliary power from boats, see Motor Craft, NFPA
302-1972 (ANSI).
555-3. Receptacles. Receptacles that provide shore power for boats
shall be rated not less than 20 amperes and shall be single and of the locking
and grounding types.
Fifteen- and 20-ampere, single-phase, 120-volt receptacles other than
those supplying shore power to boats located at piers, wharfs, and other
locations shall be protected by ground -fault circuit -interrupters.
For various configurations and ratings of locking- and grounding-typc receptacles
and caps, see Dimensions of Caps, Plugs, and Receptacles (ANSI C73-1972).
555-4. Branch Circuits. Each single receptacle that supplies shore power
to boats shall be supplied from a power outlet or panclboard by an
individual branch circuit of the voltage class and rating corresponding to
the rating of the receptacle.
555-5. Feeders and Services. The load for each ungrounded feeder and
service conductor supplying receptacles that supply shore power for boats
shall be calculated as follows:
For I to 4 receptacles 100% of the sum of the rating of the receptacles
90T
For 5 to 8 0
For 9 to 13 80%
For 14 to 30 70%
For 31 to 50 5(W
0
For 50 to 100 4(M
For over 100 30%
ARTICLE 555—MARINAS AND BOATYARDS 70-511 '
555-6. Wiring Methods. The wiring method shall be one or more of the
following identified as suitable for use where exposed to the weather or
water: (1) rigid nonmetallic conduit; (2) mineral -insulated, metal -sheathed
cable; (3) nonmetallic cable; (4) corrosion -resistant rigid metal conduit; (5)
corrosion -resistant intermediate metal conduit; (6) underground wiring that
complies with the'requirements of this Code; (7) Type MC cable.
Exception No. 1: Where flexibility is required, other types identifiedfor I
the purpose.
. Exception No. 2.- Open wiring shall be permitted by special permis-
Sion.
In granting special permission, major factors include possible contact of open wires
with masts, cranes, or similar structures or equipment.
For further information on wiring methods for various locations, see Fire
Protection Standard for Marinas and Boatyards, NFPA 303-1975.
555-7. Grounding.
(a) Equipment to Be Grounded. The following items shall be
connected to an equipment grounding conductor run with the circuit
conductors in a raceway or cable:
(1) Boxes, cabinets, and all other metal enclosures.
(2) Metal frames of utilization equipment.
(3) Grounding terminals of grounding -type receptacles.
(b) Type of Equipment Grounding Conductor. The equipment
grounding conductor shall be an insulated copper conductor with a
Continuous outer finish that is either green or green with one or more yellow
stripes.
(c) Size of Equipment Grounding Conductor. The insulated copper
equipment grounding conductor shall be sized in accordance with Section
250-95 but not smaller than No. 12,
(d) Branch -Circuit Equipment Grounding Conductor. The insulated
equipment grounding conductor for branch circuits shall terminate at a
grounding terminal in a remote panelboard or the grounding terminal in the
main service equipment.
(e) Feeder Equipment Grounding Conductors. Where a feeder sup-
plies a remote panelboard, an insulated equipment ground ng conductor
"'-Il extend from a grounding terminal in the
service equipment to a
grounding terminal in the remote panelboard.
-8. Wiring Over and Under Navigable Water. Wiring over and under
-."'-navigable water shall be subject to approval by the authority having
jurisdiction.
5-5&9- Gasoline Dispensing Stations — Hazardous (Classified) Loca-
t-i, Uons.
(a) Class 11 Division 1 Location. The following spaces shall be I
idered a Class 1. Division I location:
"(11) The space within the dispenser from its base to a level measured 4
t (1-22 in) vertically from its base.
(2) The space outside the dispenser for a distance measured 4 feet (1.22
1n) horizontally from all points of the dispenser and measured vertically
GLD0521
NEMA
LINE
NEMA NEMA
L5
L5-20R L5-20P
DYNA-MATE II'"PLUG
e See page C4 for product features
e Cord size range 16/3-10/3
c Cat. No Special Features
a' o'
GTLD:052�1:-�q Corrosion resistant
_dGED05:211 '0
1-,64-0 t'Z
Y,
SINGLE RECEPTACLES
* Seepage C3 for product features
* Use standard single receptacle
plate
Cat. No. Special Features
GL0520-C I Corrosion resistant
GL0520
GL05124
FLANGED RECEPTACLE
• Lexanft casing and flange
• Gray Noryll' face
• Accepts,# 14, 12 or 10 AWG
conductors
• Maximum mounting bolt size:
187; Centers on 1 .25" radius
at 1200
Cat. No.
GL0524
GLD0523
DYNA-MATE11 CONNECTOR
• See page C4 for Product features
• Cord size rangd 16/3-10/3
Cat. No. I Special Features
GLD0523-C I Corrosion resistant
GLD0523
GLO525
FLANGED INLET
• Lexan" casing and flange
• Gray NorylO face
• Accepts # 14, 12 or 10 AWG
conductors
Maximum mounting bolt size:
187; Centers on 1.25" radius
at 1200
Cat. No.
GLO526
�j
IYEMA
L I N E
L5
Oro 0-t�-
NEMA NEMA
L5-30R 1-5-30P
GLD0531
DYNA-MATEU'uPLUG
• See page C4 for product features
• Cord size range: 14 / 3- 8 / 3
Cat. No. "a"es
GLD0531-C Corrosion resistant
GLD0531 I spe':i"IF
SINGLE RECEPTACLES
* Seepage C3 for product features
* Minimum plate opening diameter:
1.57
* UseGE97111 plate
Cat. No. I Special Features
GL0530-C I Corrosion resistant
GLO530
GL0534
- L 'WiRt.,
GLD0533
DYNA-MATE3M CONNECTOR
FLANGED RECEPTACLE
• LexanO casing and flange
• Gray NorylL" face
• Accepts # 12, 10 or 8 AWG
conductors
• Maximur-h mounting boll size:
18 7; Centers on 1. 2 5" radius
at 120 0
Cal. No.
GL0534
• See page C4 for product features
• Cord size range: 14 / 3- 8 / 3
Col. No. I Special Features
GLD0533-C I Corrosion resistant
GLD0533
GL0535
FLANGED INLET
• LexanO casing and flange
• Gray NorylO face
• Accepts # 12, 10 or 8 AWG
conductors
• Maximum mounting bolt size:
187; Centers on 1 .25" radius
at 1200
Col. No.
GLOS35
WIAM
�1- 0'
I A"t
0
SELECTION
15AMP
20AMP
30AMP
NEMA 5-15
NEMA5-20
125 V
2-POLE
-
5- ISR 5-15P
5-20R 5-20P
3-WIRE
c.,.No. Description
Cat. No. Description
GE5262-C
GE5261-C
Duplex Recpt.
Single Recpt.
GE0520-C Single Recpt.
GE0526-C Duplex Recpt.
GROUNDING
STRAIGHT
BLADE
GED051 1 -C
GED0513-C
Plug
Connector
BOOT-15
, Protective Boot
N EMA L.5-1 5
NEMA 1.5-20
NEMAL.5-30
125 V
2-POLE
L5-15R 1.5-11 5P
LS-20R L5-20P
L5-30R 1.5-30P
3-WIRE
GROUNDING
LOCKING
Cal. -No. Description
GL0516-C Duplex Recpt.
G LD051 1 -C Plug
GLD0513-C' Connector
Cat. No. Description
GLO520-C Single Recpt.
GLD0521-C Plug
GLD0523-C Connector
Cat. No. Description
GLOS30-C Single Recpt.
GLD0531-C Plug
GLD0533-C Connector
BOOT-15 Protective Boot
BOOT-20 Protective Boot
BOOT-30 Protective Boot
NEMA L.6-15
NEMA 1-6-20
NEMA 1-6-30
250 V
2-POLE
I
1.6-11 L6 - 15 P
L6-20R L6-20P
L6.30R 1.6-30P
3-WIRE
GROUNDING
Cal No Description
GL0616-C Duplex Recpt.
GLD061 1 -C Plug
Cat. No. Description
GL0620-C Single Recpt.
GLD0621-C Plug
Cat. No, Description
GL0630-C Single Recpt.
GLD0631-C Plug
LOCKING
GLD0613-C Connector
BOOT-15 P - rotective Boot
GLD0623-C Connector
BOOT-20 Protective Boot
GLD0633-C Connector
1300T - 30 Protective Boot
NEMAL14-30
125/
NEMAL14-20
250 V
X
L14 20R C:Z� Oft L I 4-20P
G
V
(9� &
L14-30R L14-30P
3-POLE
C-1 4ims
y
y
4-WIRE
GROUNDING
Cat. No. Description
GL1420-C Single Recpt.
GLD1421-C Plug
Cat. No. Description
GL1430-C Single Recpt.
GLD1431-C Plug
LOCKING
--
GLD1423-C Connector
BOOT-20 Protective Boot
GLD11433�-C Connector
BOOT-30 Protective Boot
REPLACEMENT
125/
250 V
Recpt. Plug
Q (�
3-POLE
3-WIRE
Cat. No. Description
—
GL7310-C Single Recpt. (porcelain)
REPLACE-
MENT
GLD731 1-C Plug
GLD7313-C Connector
LOCKING
BOOT 30 Protective Boot
Non NEMA C..fi..,.,i.n
41
The General Electric line of corrosion resistant devices
is engineered with parts of plated copper alloy to fight
salt and chemical attack. In fact, there are no ferrous
parts at all. Only tough compounds such as
PVC/ABS, Lexan, Noryl, Nylon, Melamine, glazed
porcelain and Nitrile PVC — some of the most corro-
sion resistant materials available. Here are the facts:
10 Metal parts have been changed or plated to provide a
maximum resistance to corrosive atmospheres.
• Brass and Bronze parts are heavily plated.
• Steel parts have been changed to Stainless Steel or
Plated Brass. 4
0 The highly visible yellow color of GE Dynb-Mate 11
Plugs, connectors and protective rubber boots has
been maintained for Corrosion Resistant plugs, con-
nectors and boots.
0 GE Corrosion Resistant receptacles are molded in
brilliant yellow for positive identification.
IM Catalog numbering system easily identifies NEMA
configurations.
0 Dimensions are equal to basic device dimensions.
0 Receptacles fit standard size receptacle boxes.
U Duplex receptacles require standard opening duplex
plates.
13 Single 15 and 20A receptacles require standard open-
ing single receptacle plates.
Single 30A receptacles require 1.57" opening single
receptacle plate (i.e. G E cat, no. 9 7111)
RECEPTACLES
PLUGS . I CONNECTORS I BOOTS
EXISTING FIXTURES NOW PROVIDED
FOR "H" THRU "N" DOCKS.
STRIGHT BLADE DUAL RECEPTACLES
20 AMP. CIRCUIT BREAKERS
NEW MOUNTING PLATE
LOCKING SINGLE 20 or 30 AMP
RECEPTACLES
20 AMP CIRCUIT BREAKERS
CITY OF EDMONDS HARVE H. HARRISON
MAYOR
CIVIC CENTER - EDMONDS, WASHINGTON 98020 - (206) 775-2525
FIRE DEPARTMENT
DATE: May 14, 1981
TO- Port of Edmonds
Attn: Bob Yeager
456 Admiral Way
Edmonds, WA 98020
SUBJECT: PORT OF EDMONDS; FILE CODE: 591-000-046
Attached is a copy of a notice advising you that certain items are in
violation of current City Ordinances or Fire Codes.
We request the correction(s) indicated on the attached memo be
made. We will reinspect after 30 days.
Item(s) # has(have) been corrected in
accordance with our request.
Item(s) # has(have) not been corrected.
We will reinspect after days. Please advise by return
mail or by telephone your intentions or questions regarding this
matter.
= Other:
Any overlooked hazardous conditions and/or violation of the fire
regulations does not imply approval of such condition or violation.
If,we may be of further assistance, please contact this office by
calling (206) 775-2525, Ext. 247, between the hours of 8 a.m. and
5 p.m., Monday through Friday.
Yours for a safer community through fire prevention,
Stanley Olsen
Senior Inspector
Enclosure
CITY OF EDMONDS
CIVIC CENTER * EDMONDS, WASHINGTON 98020 o (206) 775-2525
FIRE DEPARTMENT
FIRE DEPARTMENT HAZARD FORM
HARVE H. HARRISON
MAYOR
BUSINESS NAME: Port of Edmonds FILE CODE: 591-000-046
ADDRESS: 456 Admiral Way
OWNER/MANAGER: Bob Yeager, Manager PHONE: 774-0549
HAZARDS:
We found numerous hazards concerning the cords being used through
-out the berths, which are the tenant's responsibility, We have enclosed
a letter which describes,certain requirements.which are to be met,
Please run copies of this letter and distribute them to your tenants
We shall reinspect the premises in approximately 30 days, toward the
end of June. Thank.you for�your cooperation.
PERSON CONTACTED: Bob Yeager
INSPECTED BY: Stan Olsen and Marc Petrella DATE: 4-,30-81
REINSPECTION DATE TENATIVE: 6-16-81 ACTUAL:
DATE: BY: COMMENTS:
DATE: BY: COMMENTS:
DATE: BY: COMMENTS:
PAGE 1 OF 2
MS:lvlO/79
CITY OF EDMONDS HARVE H. HARRISON
CIVIC CENTER - EDMONDS, WASHINGTON 98020 - (206) 775-2525 MAYOR
FIRE DEPARTMENT
May 14, 1981
Tenants of the Port of Edmonds
456 Admiral Way
Edmonds, WA 98020
f
Dear Tenants:
On a recent inspection, the Edmonds Fire Department found
many potential fire hazards concerning the cords being used
throughout the berths. The following are some of the require-
ments for electrical wiring and equipment for.marinas and boat-
yards. 'Please read this carefully and make sure your own'area
meets with the standards.
The Uniform Fire Code, Apendix F (concerning marinas),
#3(gT,—states tH'atAll electrical equipment in-
stalled and used must be in accordance with the
Electrical Code as it applies to wet, damp, and haz-
ardous locations".
The National Fire Code, Section 5-6.1, concerning
grounding, says, "Effective grounding of all non-
current carrying metal parts of the electrical system,
and.provision of suitable connection of portable
equipment, including outlets provided for the con-
nection of shore power to vessels afloat, are of
utmost importance in marinas, boatyards, boat basins,
and similar establishments. This is due to the
exposure of electrical systems and equipment to water,
damp or wet earth, and to other grounded or'partially
grounded conductive parts, and the consequent danger
to life and possibility of high sparking adjacent
to combustible materials".
The minimum size of wire for a shore power connection to be
used is 12 AWG, grounded, and twistlocked.(if possible). The
approved types of cord are as follows: SJ, SJE, SJO, SJT, SO,
SE, SOO, ST, and any other cord which has been specifically ap-
proved for use in damp areas. These letters will be marked on
the cord, or they will be attached to the cord reel on a tag.
The Fire Department shall reinspect the premises in approxi-
mately 30 days. Your compliance is required. If you have any
Letter to Port of Edmonds Tenants
May 12, 1981
Page 2
questions, or if the Fire Department can be of any assistance,
please contact our office by calling 775-2525, Ext. 234, between
the hours of 8 a.m. and 5 p.m., Monday through Friday.
Sincerely, I
Stanely A. Olsen
Senior Fire Inspector
sr
CITY OF EDMONDS HARVE H. HARRISON
MAYOR
CIVIC CENTER * EDMONDS, WASHINGTON 98020 - (206) 775-2525
FIRE DEPARTMENT
January 26, 1981
Mr. Leo Torvinen
456 Admiral Way
Edmonds, WA 98020
Dear Mr. Torvinen:
SUBJECT: STANDPIPES ON THE FLOATING DOCKS
I have received the hydraulic computations for the stand-
pipes on floats "A" through "N". It appears that the 2-inch
PVC pipe will be adequate to supply our requirements, so you
may proceed with the construction of the dry pipe system as
designed. However, one modification that should be done
immediately is to change the fitting at the east end of "H"
dock to a female type. On each dock where the Fire Department
will make its connection, a female fitting is required. Each
discharge port should be equipped with the male end and a cap
to protect the threads.
If you have any questions or if wezan be of any service
to you, contact this office by calling 775-2525, Ext. 233,
between the hours of 8 a.m. and 5 p.m., Monday through Friday.
Sincerely,
McComas
Gary
Fire Marshal
GLM: sr
RECEIVED
DEC 3 11980
gD S EIK-MR-T.,
MQbp
Reid, Middleton &
December 30, 1980
File No. 3.80
Mr. Gary L. McComas, Fire Marshal
City of Edmonds
Civic Center
Edmonds, Washington 98020
Re: Standpipes for the Port of Edmonds Floats
Dear Mr. McComas:
Associates, Inc.
Engineers 9 Surveyors 0 Planners
We have calculated the size of PVC pipe, friction loss, and pumper pressure
required to yield the flow and pressure values which you desire in connection
with the above referenced project. Our figures based on using 2-inch PVC
pipe throughout are as shown on the enclosed list.
As you can see from this listing, a 2-inch PVC standpipe on Floats F through
N will quite easily meet your requirements. Floats D and E require only 9
pounds and 2 pounds, respectively, more pumper pressure than the 200 pound
pressure you desired. This is considered to be well within the capability
of your fire apparatus. Floats A, B and C will require either slightly higher
pumper pressure, lower outer standpipe flow, or lower outer standpipe pressures
using 2-inch PVC pipe. We feel that these variations are also rather minor
and would not hamper your fire fighting capabilities. We therefore recommend
that 2-inch PVC pipe be used for the standpipes on all of the Floats A through N
at the Port of Edmonds facility. Please let us know if you concur with our
findings.
As you requested, we are also enclosing drawings furnished by the Port of
Edmonds for typical standpipe installation.
Very truly yours,
REI MI LETO ASSOCIATES, INC.
Reinhart Ju Wg
RJ: bb
Encls.
121 5th Avenue North, Suite 200, Edmonds, Woshington 98020 (206) 775-3434
PORT OF EDMONDS STANDPIPE DATA
Float
Float
Length
Standpipe
Length
Pumper
Pressure
Flow
Outer
Standpipe
Pressure
A
525
ft
420 ft
227 psi
250
gpm
100 psi
A
- Alt.
1
525
11
420 11
200 "
220
"
100
A
- Alt.
2
525
of
420 it
200
250
73
B
510
405 go
223
250
100
B
- Alt.
1
510
405 11
200
230
100
B
- Alt.
2
510
405 of
200 of
250
77
c
475
370 11
214 "
250
100
C
- Alt.
1
475
370 go
200 of
240
100
C
- Alt.
2
475
370 11
200
250
85
D
455
350 go
209
250
of
100 If
E
425
11
320 it
202
250
100 It
F
365
275 it
Less than
250
100
200 psi
required
G
195
95
If
11
H
230
125
11
it
it If
1
345
240
it
11
If 11
385
280
go
11
11 11
K
385
It
280
11
If
If If
L
335
230
11
If
M
275
170 if
If
If
it
N
255
150 of
If
F
2
4e ehl'4111V
�14' 41- gol-r-
e- - -f x -?,w 114
4`1 O*a
31,� "X 4 0.,
Z;;y l4eRle
wa4v
jy,az 6w;l,
,4NO 0`17-rINSA
0 L**t*%e m p I
z *,-* a",Pz v zp/ pe
2
Lo 0 '2411— IVI
r ke. b, A, Ic,
100,
--AIWO
r7TRAr.4Z)
6"'EMALE S&JIVL'L coul-I IN6
4//7" CREAKALIAY C17P)
4 A
E
17
"co r
A " ' 104
_4'A L E s,
Zr
.7
\AI
OLYt\4P[tm\
C-i �Fouocj U P
CITY OF EDMONDS
.454
CIVIC CENTER - EDMONDS. WASHINGTON 98020 (206) 775-2525
FIRE DEPARTMENT
Cr
Mr. Leo Torvinen
456 Admiral Way
Edmonds, WA 98020
Dear Mr. Torvinen:
HARVE H. HARRISON
MAYOR
5 (� i , 060 -o (16
September 2, 1980
SUBJECT: STANDPIPES ON THE FLOATING DOCKS
As a result of the tests done on the standpipe on dock
we can accept this system as a class II system. With a
fire department pumper supplying the system, it discharged
adequate water for two lk" fire nozzles. It is our opinion
that this type of standpipe design will work on the remainder
of the floats but that each should be designed to discharge
a minimum of 250 gallons per minute at 100 pounds pressure.
This may require increased sized piping for some of the longer
runs.
It is suggested that prior to installation, all designs
should be checked by Reid -Middleton and Associates to assure
that minimum gallonage is available at the required pressure
at the furthest discharge point. Before each installation, a
drawing complete with hydraulic computations shall be submitted
to the Edmonds Fire Department for approval.
If you have any questions, or if we can be of any more
service to you, please contact this office by calling 775-2525,
Ext. 247, between the hours of 8 a.m. and 5 p.m., Monday
through Friday.
Sincerely,
Gary�pMcComas
Fire Marshal
GLM: sr
RICHARD COLE
ATTORNEY AT LAW
SUITE 230 HARBOR BUILDING
100 SECOND AVENUE SOUTH
EDMONDS. WASHINGTON 98020
September 30, 1980
City of Edmonds
Edmonds Civic Center
250 Fifth Avenue North
Edmonds, WA 98020
ATTENTION: Chief Jack Weinz
Re: Port of Edmonds
Dear Chief Weinz:
R E C E I V E D
-)u - 11980
EDMONDS FIRE DEPT.
(206) 775-4488
The Port Commissioners of the Port of Edmonds asked me to write
and inform you that they had approved the request to provide
space for a fire engine on Port property in what is known as
the old Barton building. Approval was for a space of approximately
twelve feet by thirty feet. The entire cost of any remodeling
will be borne by the City.
The Commissioners also wanted me to inform you that that particular
building may be demolished within two to three years and there is
no assurance that substitute space will be available. Any expense
incurred by the City in making the storage space available now
may not be recovered after the building is removed.
If you have any questions about the future plans, please do not
hesitate to contact me or the Port Manager, Leo Torvinen.
RC/cag
cc: Port of Edmonds
CITY OF EDMONDB HARVE H. HARRISON
MAYOR
CIVIC CENTER e EDMONDS, WASHINGTON 98020 - (206) 775-2525
1
FIRE DEPARTMENT
June 6, 1980
Mr. Bill Karr
465 Admiral Way
Edmonds, WA 98020
Dear Mr. Karr:
SUBJECT: DISPENSING OF FLAMMABLE LIQUIDS AT THE
BOAT LOFT
We have done a great deal of research in answering your
inquiry regarding utilizing a portable fuel truck. It
appears that we can allow the use of a fuel truck to dispense
gasoline to boats within your property if the following
provisions are met:
1. The tank vehicle shall comply with all require-
ments of the Utilities and Transportation
Commission.
2. The dispensing is done on premises not open to
the public. All access shall be secured prior
to fuel transfer operations.
3. The dispensing hose does not exceed 50 feet
in length.
4. The dispensing nozzle is a listed automatic
closing type without a latch open device.
5. Night time deliveries shall only be made in
adequately lighted areas.
6. Fuel expansion space shall be left in each
fuel tank to prevent overflow in the event of
temperature increase.
7. The tank vehicle shall not be operated without
a valid permit from the Edmonds Fire Department.
8. The cargo tank shall be bonded to the fill stem.
9. Smoking by tank drivers, helpers, repairmen, or
Letter to Mr. Bill Karr
Page 2
June 6, 1980
other personnel is prohibited while they are
driving, making deliveries, filling, or making
repairs to tank vehicles.
10. No person shall park a tank vehicle at any one
Toint for longer than one hour except inside
your property and 25 feet from the property
line.
If you should have any questions about the above requirements,
please contact my office by calling 775-2525, Ext. 247, between
the hours of 8 a.m. and 5 p.m., Monday through Friday.
Sincerely,
'6 / O?cd7nv,,:::>
Gar L. McComas
Fire Marshal
GLM: lv
April 10, 1980
Mr. Leo Torvinen
Port of Edmonds
456 Admiral Way
Edmonds, Washington
Dear Mr. Torvinen:
Honeywell
98020
Confirming our discussion of Honeywell Protection Services,
we submit the following:
&tomatic Fire Alarm System
(Docks B,C,D,E)
Install one (1) Control Unit with Power Supply
Install one (1) Fire Horn
Install four (4) Manual.Pull Stations
Install twenty two (22) Infrared Detectors
Installation (per' each dock) $8953.00
Monthly Service (per each dock) $ 85.00
Automatic Fire Alarm System
(Dock A & H)
Install one (1) Control Unit with Power Supply
Install one (1) Fire Horn
Install two (2) Manual Pull Stations
Install twelve (12) Infrared Detectors
Installation (per each dock) $5,503.00
Monthly Service (per each dock) $ 61.00
Automatic Fire Alarm System
(Dock F)
Install one (1) Control Unit with Power Supply
Install one (1) Fire Horn
Install three (3) Manual Pull Stations
Install thirteen (13) Infrared Detectors
Installation Charge
- Monthly Service Charge
$5892.00
$ 65.00
HONEYWELL PROTECTION SERVICES
HONEYWELL INC., 7723 24TH AVENUE NORTHWEST, SEATTLE, WASHINGTON 98117, TELEPHONE 206/782-8200
NATIONWIDE CENTRAL STATION SERVICES
0 tie.
4 1.
Mr. Leo Torvinen
Port of Edmonds
456 Admiral Way
Edmonds, Washington 98020
page -2-
Automatic Fire Alarm System
(Dock G)
Install one (1) Control Unit with Power Supply
Install one (1) Fire Horn
Install two (2) Manual Pull Stations
Install three (3) Infrared Detectors
Installation Charge $2497.00
Monthly Service Charge $ 43.00
Automatic Fire Alarm System
(Dock I & Q
Install one (1) Control Unit with Power Supply
Install one (1) Fire Horn
Install three (3) Manual Pull Stations
Install seventeen (17) Infrared Detectors
Installation (per each dock)
Monthly Service (per each dock) $ 73.00
Automatic Fire Alarm System
(Dock J,M,K)
Install one (1) Control Unit with Power Supply
Install one (1) Fire Horn
Install three (3) Manual Pull Stations
Install sixteen (16) Infrared Detectors
Installation (per each dock) $6864.00
Monthly Service (per each dock) $ 71.00
Automatic Fire Alarm System
(Dock N)
Install one (1) Control Unit with Power Supply
Install one (1) Fire Horn
Install two (2) Manual Pull Stations
Install fourteen (14) Infrared Detectors
Installation Charge $6171.00
Monthly Service Charge $ 65.00
a
1A14
96 -Y"P4-
?t! eq� r-m- . `e 4 (-e Pr 9 ; Al, 7e
0
Mr. Leo Torvinen
Port of 94aut-ke
456 Admiral Way
Edmonds, Washington 98020
page -3-
All monthly service charges include monitoring, maintenance,
24 hour service and telephone line charges.
Installation includes all conduit needed. Cleaning of the
Infrared Detector should be done by the Port once a month for
best results.
Manual Pull Stations
(Dock A,H,N)
Install one (1) Automatic Fire Alarm Transmitter
Install one (1) Fire Horn
Install two (2) Manual Pull Stations
Installation (per each dock) $ 895.00
Monthly Service (per each dock) $ 37.00
Manual Pull Stations
(Docks J,M,K,F,G,I,L)
Install one (1) Automatic Fire Alarm Transmitter
Install one (1) Fire Horn
Install three 0 ) Manual Pull Stations
Installation Charge (per each dock) $ 950.00
Monthly Service (per each dock) $ 39.00
Manual Pull Stations
(Docks B,C,D,E)
Install one (1) Automatic Fire Alarm Transmitter
Install one (1) Fire Horn
Install four (4) Manual Pull Stations
Installation (per each dock) $1005.00
Monthly Service (per each dock) $ 41.00
4
Mr. Leo Torvinen
Port of Seetele
456 Admiral Way
Edmonds, Washington 98020
page -4-
All monthly service charges include monitoring, maintenance,
24 hour service and all telephone line charges.
On all docks electrical outlets must be furnished.
Should you have any questions, please -feel free to call me
at 789-1955.
Sincerely,
HONEYWELL PROTECTION SERVICES
A. Ashley Brinkley
Sales Representative
SAB:dt
t
CITY OF EDMONOB HARVE H. HARRISON
MAYOR
CIVIC CENTER - EDMONDS. WASHINGTON (208) 775-2625
FIRE DEPARTMENT
December 11, 1979
Leo Torvinen
Port of Edmonds
456 Admiral Way
Edmonds, Washington 98020
Dear Sir:
This letter is to advise you of the Edmonds Fire
Department's position on the moorage of boats on the inside
of the south breakwater.
The Harbor Master has the authority to permit parking
on the south breakwater on an emergency basis-. It is suggested
however, that parking in this area be strictly monitored since
it presents a.difficult tactical problem in the event of an
emergency.
JW/GM/cn
0
Sincerely,
jJa Weinz
F ir
ir Chief
Gary%Comas
Fire Marshal
a
15.710 UNIFORM FIRE CODE
7. Piping handling Class I liquids shall be grounded to control stray
electrical current.
8. Testing of piping systems shall be in accordance with Section
15.216.
(d) Dispensing. Wharves, piers, or floats at marine service stations
shall be used exclusively for the dispensing or transfer of petroleum
products to or from marine craft, except that transfer of essential ship
stores is permitted. Sales of ship stores or merchandise shall not be
allowed from an area where fuel is dispensed into the tanks of motor
craft.
1. Tanks and pumps, other than those integral with approved dis-
pensing devices, supplying flammable or combustible liquids at
marine service stations, shall be located only on shore or upon
express permission of the Chief on piers of -solid-fill type. Ap-
roved dispensing devices with or without integral pumps may
e located on shore, piers of solid -fill type; open piers, wharve's
or floating docks.
2. Dispensing of flarrunable or combustible liquids or liquefied
petroleum gases shall at all times be under the direct control of
a competent person who is fully aware of the operation, mechan-
ics, and hazards inherent to fueling of boats.
3. Di ensing of flammable or combustible liquids into the fuel
IT.
tai s of marine craft shall be by means of an approved type
hose, equipped with a listed automatic closing nozzle with latch
open device.
4. Hoses used for dispensing or transferrin% flammable or com-
bustible liquids, when not in use, shall e reeled, racked or
otherwise protected from mechanical damage.
5. Fueling of floating marine craft at other than a marine service
station is prohibited except by special authorization of the Chief.
6. No delivery of any flammable or combustible liquids shall be
made into portable containers unless such container is of ap-
proved material and construction, having a tight closure with
screwed or spring cover, so designed that the contents can be
dispensed without spilling.
7. Liquefied petroleum gas cylinders shall not be filled or dis-
charged at any petroleum marine service station without first
obtaining written permission from the Chief. Approved storage
facilities for liquefied petroleum gas cylinders shall be provided.
8. The dispensing area shall be located from other stnictures so as
to provide room for safe in ress and egress of craft to be fueled.
Dispensing units shall in A cases be at least 20 feet from any
activity involving fixed sources of ignition.
(e) Fire Prevention Regulations.
1. All marine facilities shall be maintained in a neat and orderly
manner and no accumulation of rubbish or waste oils in excessive
156
1976 EDITION 15.710
amounts shall be permitted. Any spills of flammable or com-
bustible liquids at or upon the water of marine service stations
shall be reported immediately to the Fire Department and juris-
dictional authorities.
2. Metal containers with tight -fitting or self-closin It metal lids shall
be Erovided for the temporary storage of com ustible trash or
rub ish
3 . . . . . . . . . . . ..... t t�oz'ae—'W�itheciw:i�tean,�.,mftueI
s- serwing�S --man-
_E1
11 no crAtZs1la-11 vessel of
,46057 Taccupying-a -Dertil _atan.yridfih7& service—sta'ti6—n.)
4. No construction, maintenance, repair or reconditioning work
involving the use of open flames or arcs or spark -producing
devices shall be performed at any marine service station facility
or within 50 feet of the dispensing facilities including piers,
wharves, or floats. The Chief may grant permission in �vriting to
make repairs provided no fueling is done at the pier, wharf, or
float during the course of such emergency repairs.
5. All electrical equipment installed and used must be in accord-
ance with the Electrical Code as it applies to wet, damp and
hazardous locations. Cleady identified emergency switches read-
ily accessible in case of fire or physical damage at any dispensing
unit shall be provided on each main float and at the shore ap-
proach to the pier, wharf or floatinp dock, so interlocked as to
shut off power to all pump motors rom any individual location
and reset only from the master switch. Each switch to be identi-
fied by an approved sign "EMERGENCY PUMP SHUTOFF.'*
The master switch shall be set in the "OFF" position before clos-
ing the marine service station at any time. Pressure systems shall
incorporate with each turbine an indicator light illuminated
when the turbine is running. Said light shall be visible from the
sbore approach and from the dispenser location and suitably
identify the system served.
6. Smoking or open flames shall be prohibited within 50 feet of
fueling operations. "NO SMOKING" signs shall be posted con-
spicuously about the premises. Such signs shall have letters not
less than 4 inches in,height on a background of contrasting color.
7. Boat owners or operators shall not offer their craft for fueling
unless the tanks being filled are properly vented to dissipate
fumes to the outside atmosphere.
8. There shall be prominently displayed at the face of each %vbarf,
pier or float at such elevation as to be clearly visible from the
'signs with letters
decks of marine craft being fueled, a sign or
not less than 3 hiches in height on a background of contrasting
color bearing the following or equivalent wording:
157
15.710 UNIFORM FIRE CODE
7. Piping handling Class I liquids shall be grounded to control stray
electrical current.
8. Testing of piping systems shall be in accordance with Section
15.216.
(d) Dispensing. Wharves, p iers ' or floats at marine service stations
shall be used exclusively for the dispensing or transfer of petroleum
products to or from marine craft, except that transfer of essential ship
stores is permitted. Sales of ship stores or merchandise shall not be
allowed from an area where fuel is dispensed into the tanks of motor
craft.
1. Tanks and pumps, other than those integral with approved dis-
pensing devices, supplying flammable or combustible liquids at
marine service stations, shall be located only on shore or upon
express permission of the Chief on piers of solid -fill type. Ap-
roved dispensing devices with or without integral pumps may
e located on shore, piers of solid -fill type, open piers, ,vharve's
or floating docks.
2. Dispensing of flammable or combustible liquids or liquefied
petroleum gases shall at all times be under the direct control of
a competent person who is fully aware of the operation, mechan-
ics, and hazards inherent to fueling of boats.
3. Dis�ensing of flammable or combustible liquids into the fuel
tan 's of marine craft shall be by means of an approved type
hose, equipped with a listed automatic closing nozzle with latch
open device.
4. Hoses used for dispensing or transferring flammable or com-
bustible liquids, when not in use, shall be reeled, racked or
otherwise protected from mechanical damage.
5. Fueling of floating marine craft at other than a marine service
station is prohibited except by special authorization of the Chief.
6. No delivery of any flammable or combustible liquids sball be
made into portable containers unless such container is of ap-
proved material and construction, having a tight closure with
screwed or spring cover, so designed that the contents can be
dispensed without spilling.
7. Liquefied petroleum gas cylinders shall not be filled or dis-
charged at any petroleum marine service station without first
obtaining written permission from the Chief. Approved storage
facilities for liquefied petroleum gas cylinders shall be provided.
8. The dispensing area shall be located from other structures so as
to provide room for safe ingress and egress of craft to be fueled.
Dispensing units shall in all cases be at least 20 feet from any
activity involving fixed Sources of ignition.
ke) Fire Prevention Regulations.
1. All marine facilities shall be maintained in a neat and orderly
manner and no accumulation of rubbish or waste oils in excessive
156
1976 EDITION
15.710
amounts shall be permitted. Any spills of flammable or com-
bustible liquids at or upon the water of marine service stations
shall be reported immediately to the Fire Department and Juris-
dictional authorities.
2. Metal containers with tight -fitting or self-closin metal lids sball
be Erovided for the temporary storage of corntustible trash or
rub ish.
,3—No—_;�e_s_s&V.or fuel
raft-Aball e., p or b thed
o4*.s=sUe--r-v', ,g-a-,mann,e-ser.vi,cewstaii"o*iiOwe—xeept 'a
op a' in
eratioil's aZWc ftvshalllpl�e, ade fast to any other _yess ' e ' or�,
0,
6aft 6 cupying a berth at any marine service station.
4. No construction, maintenance, repair or reconditioning work.
involving the use of open flames or arcs or spark -producing
devices shall be performed at any marine service station facility
or within 50 feet of the dispensing facilities including piers,
wharves, or floats. The Chief may grant permission in %vriting to
make repairs provided no fueling is done at the pier, wharf, or
float during the course of such emergency repairs.
5. All electrical equipment installed and used must be in accord-
ance with the Electrical Code as it applies to wet, damp and
hazardous locations. Clearly identified emergency switches read-
ily accessible in case of fire or physical damage at an), dispensing
unit shall be provided on each main float and at the shore ap-
proach to the pier, wharf or floatinf dock, so interlocked as to
shut off power to all pump motors rom any individual location
and reset only from the master switch. Each switch to be identi-
fied by an approved sign "EMERGENCY PUMP SHUTOFF."
The master switch shall be set in the "OFF" position before clos-
ing the marine service station at any time. Pressure systems shall
incorporate with each turbine an indicator light illuminated
\vhen the turbine is running. Said light shall be visible from the
shore approach and from the dispenser location and suitably
identify the system served.
6. Smoking or open flames shall be prohibited within 50 feet of
fueling operations. "NO SMOKING" signs shall be posted con-
spicuously about the premises. Such signs shall have letters not
less than 4 inches in height on a background of contrasting color.
7. Boat owners or operators shall not offer their craft for fueling
unless the tanks being filled are properly vented to dissipate
fumes to the outside atmosphere.
8. There shall be prominently displayed at the face of each \vharf,
pier or float at such elevation as to be clearly visible from the
decks of marine craft being fueled, a sign or signs with letters
not less than 3 inches in height on a background of contrasting
color bearing the following or equivalent wording:
157
. 0.,
CITY OF EDMONDS
CIVIC C�NTER - EDMONDS, WASHINGTON 98020 - (206) 775-2525
COMMUNITY DEVELOPMENT DEPARTMENT
June 19, 1979.
HARVE H. HARRISON
MAYOR
Bob Yeager
Port of Edmonds
456 Admiral Way
Edmonds, Wa.. 98020
BUILDING MAINTENANCE
By let*ter dated May 22,.1979, you were asked to state
your intentions in regard to rehabilitation or removal
of -several structures on.your property. An answer was
requested before June 18, 19.79 but has not been received.
Unless a response is received before July 2, 1979, it
will be necessary for me to invoke the provisions of
the Uniform Code for the Abatement of Dan-erous Buildings,
and commence abatement procee.dings.
Harry M7 utt
Building Official
HMW/ae
cc: . Fire Dept.V-"'^
14AA Dibble
State-Electrical.Inspector
0.
0
CITY OF EDMONDS HARVE'H. HARRISON
I . MAYOR
CIVIC CENTER - EDMONDS, WASHINGTON 98020 - (206) 775-2525
COMMUNITY DEVELOPMENT DEPARTMENT
May 22, 1979
Bob Yeager
Port of Edmonds
456 Admiral Way
Edmonds, Wa.. 980-20
BUILDING MAINTENANCE
As you are aware, the Building Division, Fire Department
and the State Electrical inspector have made inspections
of several structures on Port property. The following
was noted:
1) Several of the older buildings, are in an advanced
stage of general dilapidation and deterioration.
2) There are obvious structural deficiencies requiring
repair.
3). There is a general,lack of maintenance and repair.
4) There is rion-conforming and hazardous wiring in
several structures.
5) There is evidence of unsanitary plumbing.
The Uniform Building Code requires that buildings and
structures be maintained in a safe and sanitary condition.
Unless action is taken to comply with the code, the structures
may be deemed Dangerous Buildings (Chapter ll.'05 City Code)
and ordered vacated, repaired or removed.
Pleas.e indicate your intentions before June 18, 1979.
itcutt
Building Official
HMW/ae I
cc: Fire Dept.V-*'-
MAA
State Elect. Inspector
CITY OF EDMONDS
CIVIC CGNT�R - 6DMONDS, WASHINGTON 98020 - (2b6) 775-2525
COMMUNITY DEVELOPMENT DEPARTMENT
May- 14, 1979
Bob Yeager
Port of Edmonds
456 Admiral Way
Edmonds, Wa. 98020
BUILDING MAINTENANCE
HARVE- H.- HARRISON
MAYOR
After a routine inspection of Port buildings,
the Fire Department has referred to this office
a memorandum indicating that there is dilapidation,
deterioration and possible structural deficiencies.
in several of the structures between the Yacht
Club and the Port Office.
In order'that this department may make an inspection
to determine what corrective measures may be re-
quired, please -contact the undersigned.aL 775-2525.
Harry IV. Whitcutt
B uildin
Official,
HMW/ae
cc: Fire Dept.boollo^
CITY OF EDMONDS HAHVE H. HARRISON
MAYOR
CIVIC CENTER - EDMONDS. WASHINGTON 98020 (206) 775-2525
FiRE DEPARTMENT
August 9F 1978
Reid, Middleton & Associates, Inc.
324 Main Street
Edmonds, Washington 98020
RE: EDMONDS FISHING PIER SERVICE BUILDING
Gentlemen:
On August 9, 1978, the Fire Prevention Bureau reviewed
plans submitted by you for the above mentioned building.
Listed below are the Fire Department requirements for
your situation:
1. Provide extinguisher for service area,* minimum,
rating 2:A, 10:B,C.
Any overlooked hazardous condition and/or violation of
the fire regulations does not imply approval of such
condition or violation. For further information, please
contact this office at 775-2525, extension 247.
Sincerely,
Jack F. Cooper
Fire Chief
Gary McComas
Fire trshal
GLM/amm
0
CITY OF EDMONDS HARVE H. HARRISON
MAYOR
CIVIC CENTER - EDMONDS. WASHINGTON 98020 (206) 775-2525
FIRE DEPARTMENT
June 30, 1978
Mr. Bi'll Karr
Boat Loft, Inc.
465 Admiral Way
Edmonds,- WA 98020
RE: BOAT LOFT, INC. - FILE CODE 885-000-001
Dear Sir:
on June 27, 1978, your building was inspected by members of -
the Edmonds Fire Prevention Bureau.
We request the following corrections:
1. Properly splice and secure wires located in ceiling
are& above work bench'in back room.
2. Provide a permanent mounting bracket for the fire
extinguisher so that the top of the extinguisher is
not more than five feet above the floor and the bot-
tom not less than.18 'inches above grade.
3. Replace combustible ' waste containers in back room
work area with approved noncombustible types.
Plastic.liners may be used in approved containers.
4. Place fire extinguisher sign ninety degrees to middle
extinguisher box.
5. Place fire extinguisher sign on front -of south end
extinguisher box.
The Fire Department will reinspect your building after 30 days.
If we may be of further assistance, please contact this office
(775-2525, Ext. 247)-, business'hours 9:00 A.M. to 5:00 P.M.
Yours for a safer community through fire prevention,
Jack F.. Cooper
Fire Chief
Gerald Ehtee
Inspector
GE/amm
CITY of EDMONDS
Civic Center - Edmonds, Washington 98020 - Telephone (206) 775-2525
March 17, 1978
Mr. Leo Torvinen
Port of Edmonds
456 Admiral Way
Edmonds, WA 98020
RE: PORT OF EDMONDS - FILE CODE 591-000-0'46
Dear Sir:
On March 3, 1978, the Port of Edmonds was inspected by members
of the Edmonds Fire Prevention Bureau.
We request the following corrections:
1. Center the flammable liquid storage building
between the mid -marina storage building. Center
the garage on a suitable foundation, provide
proper security to the building and post
"NO SMOKING" signs on all four sides.
The Fire Department will reinspect your building after 30 days.
If we may be of further assistance please contact this office
(775-2525, Ext. 247)9 business hours, 9:00 A.M. to 5:00 P.M.
Yours for a safer community through Fire Prevention,
Jack F. Cooper
Fire Chief
Tom Tyszko
Inspector
TT/dg
JAMES H. REID
LEROY F. MIDDLETON
C. WAYNE JONES
LLOYD H. NELSON
UC712111717 E, -I D�
DEC 141- 11974
Rea, 7&4UWoa & e4"4c&&4, 1". ENGINEERS 9 SUtyMbjffi§FtRIPIAM. ERS
6�91-000 _0q6
City of Edmonds
Fire Department
Edmonds Civic Center
Edmonds, WA 93020 V
Gentlemen;
324 Main Street 9 Edmonds, Washington 98020 e (206) 775-3434
December 13, 1977
File No. 3,50
Re; Port of Edmonds
Occupancy of the Pointer Willamette
Building
Until such ti ' me as a determination has been made as to the final
disposition or use of the Pointer Willa ' mette Building as it relates to the
Portis overall comprehensive development plan, whic h has not yet been
completed, the Port of Edmonds is desirous to allow an interim temporary
occupancy to one of its tenants for the purpose of working on crab traps.
Such use will not entail any structural or architectural changes at this
time, and it is our understanding that the tenant will add only a new
minimal lighting circuit.
Please be advised -that this office has inspected the building for
structural damage that may have occurred from the fire at the adja cent
buildings and find that the building as it now exists did not sustain
structural damage from the fire and is suitable for the intended purpose.
Very truly yours,
REID, MIDDLETON & ASSOCIATES, INC,
John 0. Olsen
JOO/mb
cc: Port of Edmonds
MUNICIPAL ENGINEERING e WATER SUPPLY *WASTE TREATMENT* SURVEYS & CADASTRAL ENGINEERING
AIRPORT PLANNING & DESIGN e MARINAS o PORT & INDUSTRIAL DEVELOPMENT o FEASIBILITY STUDIES
0
CITY OF EDIVIONDS HARVE H. HARRISON
MAYOR
CIVIC CENTER * EDMONDS, WASHINGTON 98020 s (206) 775-2525
FIRE DEPARTMENT
November-7, 1977
Mr. Ralph M. Loudin
1600 Seattle Tower
Seattle, WA 98101
RE: CITY FIRE CODE
Dear Mr. Loudin:
On November 1, 1972, the City of Edmonds was operating
from the 1971 edition of the Uniform Fire Code. In your -
letter you question the state of compliance of the Port of
Edmonds. In light of the fact that the 1971 Uniform Fire
Code had only been in effect since October 16, 1972, 1 would
question their compliance.
Prior to October 16, 1972, the City of Edmonds was
operating from the 1965 Fire Prevention Code. The Port of
Edmonds was inspected on January 1, 1971, and at that time
they were complying with the 1965 Fire Prevention Code. Copies
of this Code are no longer available to us.
Yours for a safer community through fire prevention.
Sincerely,
EDMONDS FIRE DEPARTMENT
Jack F. Cooper, Fire Chief
ZiK IP :5.)
Skip Simmons
Fire Prevention Inspector
SS/gm.
0 0 %
Noyember 2, 1977
MEMO TO: Noelle Charleson, Acting Director
Community Development Department
FROM: Jack Cooper, Fire Chief
Fire Department
SUBJECT: PORT OF EDTIONDS' APPLICATION FOR A
SHORELINE SUBSTANTIAL DEVELOPMENT PERMIT
The only Fire.Department recommen&Ltions at this time
would be the -placement of fire extinguishers as required
by the Fire Code (Section 13.301). This includes the
placement of,one (1) additional fire extinguisher (minimum
rating to be 4:A-40:.B,C') on each new addition for routine
fire protection.
JFC:gm
6-
CITY OF EDMONDS
CIVIC UNTER - eDMONDS, WASHINGTON 98020 9 (206) 775-2525
FIRF- Dr=PARTMr=NT
July 19, 1977
Mr. Bill Karr
Boat Loft, Inc.
465 Admiral Way
Edmonds, WA 98020
RE: BOAT LOFT - FILE CODE 885-000-001
Dear Sir:
HARYG H. HARRISON
MAYOR
On July 15, 1977, your business was inspected by members of
the Edmonds Fire Prevention Bureau.
We request the following corrections:
1. Fire extinguishers: Have all fire extinguishers
serviced.
a. Office extinguisher
b. Yard extinguishers
It is required that some type of physical protection
(weather shelter) be provided for both of the yard
extinguishers. This is to prevent damage from boats,
cars, fork lifts and inclimate weather.
2. Remove excessive accumulations of used lumber.
3. Discontinue the practice of allowing tenants to,
store portable containers of flammable liquids
(5 gallon cans) on the boat storage sight.
4. Smokeless shotgun powder: The possession and
storage of smokeless powder at your location is
prohibited by the Uniform Fire Code, Article II.
It is requested that this explosive be removed
immediately.
5. Exit door: Revolving, sliding, and overhead doors
shall no:E be used as required exits. Provide an
approved exit door as required in the Uniform
Building Code, Chapter 33.
Mr. Bill Karr
Page 2
July 19,'1977
The Fire Department will reinspect your building after 30
days.
If we may be of further assistance please contact 'this
office (775-2525, Ext. 247), business hours, 9:00 A.M. to
5:00 P.M. I
Yours for a safer community through Fire Prevention,
Jack F. Cooper
Fire Chief
Bill Angel
Inspector
SS/asd
cc. Harry Whitcutt, Building Official
0
CITY of EDMONDS
Civic Center - Edmonds, Washington 98020 Telephone (206) 775-2525
Building Department
July 26, 1974
Mr B I rr
* I el --COG
BoAt Lo t-
4 461 Admiral
6 Admiral Way
Edmonds, Washington
Dear Mr. Karr: Re: Pemit #730408
An Inspection on Friday Ju'ly 26, Indicated that your Installation
is generally In full use. You are reminded that some of the re-
quirements indicated on the approved plans have not been compiled
with,. The requirements referred to have to do with fire safety.
If you have any questions In regard to the above mentioned in
spection please call this office.
Very truly yours..
ED DS BUILDI,�G DEPARTMENT
Perry B. Sp nfel r
.Building Inspector
PBS/ae
cc: f 1 re dept.