6817 157TH PL SW.PDF0 1111111111 815 6817 157TH PL SW fffigUl Grou October 11, 2013 Northwest, Inc. Ms. Pinder Gill c/o Robbins and Company Attn: Charlene Martinez 818'SW 142nd Street Burien, WA 98166 GeotechniGal Engineers. Geologists & Environmental Scientists G-3552 Subject: GEoncHNicAL HAzmws ANALYns Proposed Foundation Underpinning Gill Residence 6817 - 157' Place SW Edmonds, WA Ref. 1. City of Edmonds, "Planning Division Comments for Building Permit File BLD- 2013-1003, Gill Foundation," dated October 2, 2013. 2. Plan Sheet S I - Foundation Plan and Details, titled, "Gill Residence, 6718 157'b PI SW, Edmonds, WA 98026," dated 9/12/13, by Hayman Engineering. Dear Ms. Pinder, Robbins, and Company is proposing to underpin of a portion of the house foundation on the northeastern side of the house.. The subject, residence is located at the top of a steep slope that is identified as a landslide hazard area by the City of Edmonds. The' City has requested a geotechnical hazards analysis to ensure that the scope of work will comply with the critical areas ordinance. For this analysis, we reviewed the area geologic map, the area soil survey map and the above referenced underpinning plan, Sheet S 1, and conducted a site visit on October 9, 2013. Geology Review According to the area geologic map' the soils in the project area consist of Glacial till (Qvt) underlain by Advance outwash (Qva). These soils were deposited during the Fraser glaciation period that ended some 12,000 years ago. Glacial till is mapped on the highland area above the slope and soils on the upper portion of the slope are mapped as Advance outwash. Glacial till Minard J. P., 1983, "Geologic Map of the Edmonds East and Part of the Edmonds West Quadrangles, Washington," U.S. Geological Survey, Miscellaneous Field Studies, Map MF- 1541, Scale 1:24,000. OCT 112013 6 SEhNCES CT'-i- DE'V&0FAh-'i`1' MY OF EDMONDS 13240 NE 20th Street,. Suite 10 Bellevue, Washington 98005 Phone 425/649-8757 Fax 425/64S "TREET FILE October 11, 2013 Geotechnical Evaluation Gill Foundation Underpinning G-3552 Page 2 consists of a -glacially consolidated mixture of sand, silt, clay and gravel deposited under glacial ice. Advance outwash consists of glacially consol idated pebbly sand deposited by streams issuing from the advancing ice sheet. The geologic map does not identify the site or.the slope as a landslide area. Soil.Survey Review According to the Soil Survey of Snohomish County2, the soils are mapped as Alderwood-Everett gravelly sandy loams, 25 to 70 percent slopes. The Alderwood-E verett gravelly sandy loam unit is described as being on till plains, terraces, and outwash plains. It also includes colluvial -soils, slump areas, and escarpments.. Based on the geology, the soil is classified as Everett soil, which formed in glacial outwash sand and gravel -and is very deep, has a high permeability, ana has a moderate water erosion potential. Site Conditions The steep slope is located on the northeast side of the house. The slope has an estimated gradient of around 40. percent. The slope is vegetated with trees, except below the house which is vegetated with blackberry vines. The blackbe rry area may have been previously cleared. The top of the slope is located about 12 feet from the north comer of the house and the top of the. slope extends further from the house to the southeast. A relative level concrete patio area is located between the house and top of slope. A wood fence is located along the top of the slope. A 4 foot long 1/2-inch steel rod,was used to probe the soils next to the house and along the top of the slope. Loose soil is present along the top of the slope. Dense soil was encouxitered at a depth of 3.5 to 4 feet at the north comer of the house. Underpinning Scope Underpinnig the house will require hand excavation next to the house foundation to install the pin. piles. The work will be performed on the level ground within the steep slope buffer. 2 1983, "Soil Survey of Snohomish County Area Washington," U.S. Department of Agriculture, Soil Conservation Service. GEO Group Northwest, Inc. October 11, 2013 Geotechnical Evaluation Gill Foundation Underpinning G-3552 Page 3 Excavation to install the pin piles will be limited in size and the excavated soil will be temporarily stockpiled next to the excavation. Upon completion of the pin pile installation the excavation will be backfilled with the stockpiled.soil. During wet weather we recommend that stockpiled soil be covered with plastic for erosion protection. Conclusions No scarps, tension cracks, or other signs of slope instability were observed above the top, of the slope or on. the upper portion of the slope below the house during our reconnaissance. The slope generally appears to be stable. Based on the geology, the site conditions observed and the limited scope of the proposed underpinning work, it is our professional opinion that the proposed scope of the underpinning work will not harm the critical area or adjacent property. In Accordance with ECDC 23.80.070.A.2. it is our professional opinion that: A. The proposed underpinning work will not increase surface water discharge or sedimentation to adjacent properties beyond the conditions prior to the start of work; B. The proposed work will not decrease slope stability on adjacent properties; and, C. Such alterations will not adversely impact the steep slope critical area or other critical areas. LUMTATIONS 'This report has been prepared for the specific application to the subject project. The findings and recommendation& stated herein are based on the literature reviewed, our field. observations, and our experi.ence.-and judgement. The recommendations are our professional opinion derived in a manner con I sistent with the level of care and skill ordinarily exercised by other members of the profession currently practicing under similar conditions in this area and within the budget constraint. No warranty is expressed or implied. GEO Group Northwest, Inc. October 11, 2013 G-3552 Geotechnical Evaluation Page 4 Gill Foundation Underpinning Please contact us if you have any questions regarding this report. Sincerely, GEO GROUP NORTHWEST, INC. Wade J. Lassey Engineering Geologist William Chang, P.E. Principal . - V�P'.M CH ,N A ��,!FGIS SIO N A\-�W GEO Group Northwest, Inc. - NN 0 -116 0 ed Ge ade I LEMSey City of Edmonds Critical Area Notice of Decision Applicant: pincl-w (Im Property Owner: P � Y1 ck'r C-1 I' I I Critical Area File C, P- A 2, 0 1 '.:� 0 Permit Number: 13L-0 2-013 3 Site Location: S 1 -7 15-7T,, p I 5V I Parcel Number: 0 D 115-7 1 DOO 00 Project Descriptio n: fvundai�on LAn4CYPiVJVIfYI) F� Conditional Waiver. No critical area report is required for the project described above. There will be no alteration of a Critical Area or its required buffer. The proposal is an allowed activity pursuant to ECDC 23.40.220, 23.50.220, and/or 23.80.040. The proposal is exempt pursuant to ECDC 23.40.230. F� Erosion Hazard. Project is within erosion hazard area. Applicant must prepare an erosion and sediment contro'p'an in compliance with ECDC 18.30. A eaR ort Required ' The proposed project is within a critical area and/or a critical area C rit-cal r �p b uf r crI r fe and a tica a ea report is required. A critical area report has been submitted and evaluated for compliance with the following criteria pursuant to ECDC 23.40.160: 1. The proposal minimizes the impact on critical areas in accordance with ECDC 23.40.120, Mitigation sequencing; 2. The proposal does not pose an unreasonable threat to the public health, safety, or welfare on or off the development proposal site; 3, . _Z The proposal is consistent with the general purposes of this title and the public interest; 4. Any alterations permitted to the critical area are mitigated in accordance w,ith ECDC 23.40.110, Mitigation requirements. 5. V The proposal protects the critical area functions and values consistent with the best available science and results in no net loss of critical functions and values; and 6. The proposal is consistent with other applicable regulations and standards. Unfavorable Critical Area Decision. The proposed project is not exempt or does not adequately mitigate its impacts on critical areas and/or does not comply with the criteria in ECDC 23.40.160 and the provisions of the City of Edmonds critical area regulations. See attached findings of noncompliance. Favorable Critical Area Decision. The proposed project as described above and as shown on the attached site plan meets or is exempt from the criteria iii ECDC 23.40.160, Review Criteria, and complies with the applicable provisions of the City of Edmonds critical area regulations. Any subsequent changes to the proposal shall void this decision pending re -review of the proposal. F-1 Conditions. Criti cal Area specific condition(s) have been applied to the permit number referenced above. See referenced permit number for specific condition(s). GImA SomivJ- Reviewer Signature Date Appeals: Any decision to approve, condition, or deny a development proposal or other activity based on the requirements of critical area regulations may be appealed according to, and as part of, the appeal procedure, if any, for the permit or approval involved. Revised 12/16/2010 � 8 9 0 19 C5 - STREET FILE CITY OF EDMONDS 250 - 5TH AVE. N. - EDMONDS, WA 98020 - (206) 771-0220 - FAX (206) 771-0221 COMMUNITY SERVICES DEPARTMENT Public Works * Planning * Parks and Recreation * Engineering February 3, 1992 Mrs. Githens 6821 157th Pl SW Edmonds, WA 98026 RE: Address Change LAURA M. HALL MAYOR PETER E. HAHN DIRECTOR I have contacted the City Building Official and the City Fire Inspector in response to your request for re -addressing your house to 6817 157th PI SW and we have all concurred that new addressing needs to be done. The house permit was issued under 6821 157th Pl SW, but it is the City's understanding that all subsequent paperwork (mortgage$ etc.) was issued under 6817 157th PI SW and that the house numbers were posted as 6817. City records and utility billing are the only departments that have ever used 6821 157th PI SW. Therefore, your address will be changed, per your request. The City will notify all applicable City departments of this address change. It will be your responsibility to notify all others, including the Post Office, if necessary. Thank you, Sharon Nolan Permit Coordinator cc: Fire & Police ,Stree-t--Fi--,l--es Address Files Public Works Utility Billing 0 Incorporated August 11, 1890 0 Sister Cities International — Hekinan, Japan CITY OF EDMONDS 1P/NEW 1:1 ADDITION El RETIREMENT e%"rr.% LE ASSET INFORMATION SHEET 0 1 MEET Fl ASSET NO, ADDITION TO ASSET NO. - DESCRIPTION SERIAL NO. LOCATION '00 DEPYNO. *PURCHASE ORDER NO. PURCHASE ORDER DATE COST PROJECT NUMBER "'.-oeeol 1-2 PROJECT COMPLETION DATE /0/&/ Ad - COST 5�� B.A.R.S. ACCOUNT NO. 63 ESTIMATED LIFE INITIATED BY DATE APPROVED BY "SUBMIT ASSET INFORMATION SHEET WITH FINAL PAYMENT REQUEST *SUBMIT ASSET INFORMATION SHEET UPON CLOSE OF PROJECT ACCOUNTING ONLY 2/DEPRECIATE MONTHLY DEPRECIATION AMOUNT ANNUAL DEPRECIATION AMOUNT 0 G.L. ENTRY REFERENCE DATE t(p) INITIAL DEPARTMENT FILE 4- �oe� VERIFIED BY PROCESSED BATCH NO.- K31 00 CD CITY of EDMONDS For Inspection Call 771-3202 Address of Construction: Property Legal Description (Include all easements): ,IC,T-,I, we SIDE SEWER Owner an d/or Builde r: r"91 ro A) tado"o Contractor & License No: Singl:e Family Residence Mul ti-Fami ly Commercial PERMIT NO. P . - E 6c� (No. of Units (No. of fixture Units CYNNWOZ00 LME Invasion into City Right -of -Way: No 0--� Yes — (If Yes, Right -of -Way Construction Permit required. Call One -Call -Center (1-800-424-5555) before any excavation.) I Cross other Private Property: No Yes — (If Yes, easement required, attach legal description and county easement number.) PLP,SE READ THE ITEMS LIS,ED ON THE BACK REC OCT 2 11988 I T +i certify that I have read and shall comply PUBLIC WORKS Vte with the items listed on the back. Permit Fee: Trunk Charge: Assessment Fee: Partial Inspection: Issued By: I M bate Issued: /0-ZI - Receipt No.: Comments Date Initial Final Inspection Approved: t 6 -) ( '�t ;"*"" M- Date —rn—i—t i a 1 Rejected: Reason Initial ** PERMIT MUST BE POSTED ON JOB SITE ** E�91'1 EFTW2;Iq W-9 Wh.ite Copy - File Green Copy - Inspector Buff Copy - Applicant NOTICE: No warranty of accuracy. The information shown on the attached map(s) was compiled for use by the City of Edmonds, its Employees and Consultants. The City of Edmonds does not warrant the accuracy of anything set forth on these map(s). Any person or entity requesting a copy should conduct an independent inquiry regarding the information shown on the map(s), including, but not limited to, the location of any sewer stub shown. Such sewer stubs may or may not exist and may or mav not exist at the location shown. Neither the City of Edmonds nor its employees or officers shall be liable for the information given on map(s), nor for any one representation provided based upon said map(s). I a City of Edmonds Side Sewer Drawing EASEMENT NO - -------------------------------------------- NEW CONSTRUCTION REPAIRS LID NO . .................. ASMT. NO . .................. OWNER------------------------------------------------------------------------------------------------ CONTRACTOR .................... PERMIT NO. BLOCK NO. ..- --------- --------------------- JOB ADDREde - -- ------------------------------------------------------------ ...... LEGAL DESCRIPTION: LOT NO . ........ (e- ----------------------- t4 A I �tg N t N., kM-Trto' PWW-000 1 - 11175 (R EV. 11/78) ----------------------------------------------------------------------------------------------------------------------- ------------- --------------- NAMEOF ADDITION ----------------------------- I ----------------------------------------- ............................. B ------------------------ ��6 K4 11,1, rAW-fri- "'W CITY OF EDMONDS USE ZONE CONSTRUCTION PERMIT APPLICATION ME (OR NAME OF BUSINESS) A Adventure Construction mATLING ADDRESS F. 0. B ADDRESS66Z/ _EGAL DESCRIPTION CiT �CK SUBDIVISION NO. I? ' hayk TESCP PUBLIC RIGHT OF WAY PER OFFICIAL STREET MAP APPROVED BY Lynn-vrood, Wa. ?76-7992 EXISTING 40 - REQUIRED DEDICATION NAME PROPOSED 4E:�) RIGHT OF WAY CONSTRUCTION PERMIT REQUIRED: ADDRESS STREET USEPERMIT REQUIRED,"' SEE ENGINEERING MEMO DATED 'ITY I TELEPHONE NUMBER /qt-, REMARKS NAME A Adventure Construction ZDDRESS 8 E M ARKS P. 0, Bo.x 6035 It-r- k,1jt_LEJ7- METE ) DING SUPPLY SIZE RE UNITS R ,�ZE Z_1TY TELEPHONE NUMBER V9 J� , 7 -7/1" REMAR Lynnwood , Wa 226 -2c)92 I STATE LICENSE NUMBER V I Tt� 0 AD V34 Ok 12 t MA SIGN AREA ENV. REVIEW ADB NO. Legal Description of Property - include all easements ALLOWED PROPOSED COMPLETE i EXEMPT (show below or attach four copies) I I SHORELINE 0 Steele Park Lot 6 6817-1-57th P1. S.W. LXJ NEW RESIDENTIAL 14 PLUMBING ADD/ALTER COMMERCIAL MECHANICAL REPAIR RETAINING WALL SIGN DEMOLISH EXCAVATE OR FILL FENCE REMODEL PRE -MOVE INSP.1 OCOMPLIANCE I x _ FT) swim _INSP. POOL WOOD STOVE/ INSERT 0 APT. BLDG RENEWAL NUMBER OF -STORIES NUMBER OF DWELLING 2 UNITS 1 NATURE OF WORK TO BE DONE (ATTACH PLOT PLAN) VARIANCE OR CU PLANNING REVIEW BY ATE r YARDS HEIGHT I LOT COVERAGE I FRONT SIDE REAR CHECKED BY OF CONSTRUCTION CODE HE-IGHT ITYPE I SPECIAL INSPECTOR AREA OCCUPANT REQUIRED JOCCUPANCY GROUPe? LOAD n YES L _3_ REMARKS PROGRESS INSPECTIONS PER LIBC 305 lcl�_41_ PLAN CHECK FEE BUILDING I PLUMBING MECHANICAL This Permit covers work to be done on private property ONLY GRADING/FILL Any construction on the public domain (curbs, sidewelks, STATE SURCHARGE driveways, marquees, etc.) will require separate permission. Permit Application: 180 Days Permit Limit: 1 Year - Provided Wor4 is Started Within 180 Days ENERGY CODE "Applicant, on behalf of his or her spouse, heirs, assigns and o successors in interest, agrees to indemnify, defend and hold harmless the City of Edmonds, Washington, its officials, m a: employees, and agents from any and all claims for damages of < whatever nature, arising directly or Indirectly from the issuance T of this permit. Issuance of. this permit shall not be deemed to PLAN CHECK DEPOSIT 0 modify, waive or reduce any requirement of any city ordinance 0 nor limit in any way the City's ability to enforce any ordinance provision." TOTAL AMOUNT DUE I hereby acknowledge that I have read this application; that the information given is correct; and that I am the owner, or the duly ATTENTION authorized agent of the owner. I agree to comply with city and state laws regulating construction; and In doing the work authoriz- THIS PERMIT ed thereby, no piirson will be employed in violation of the Labor AUTHORIZES ONLY THE Code 5APe State of Washington relating to Workmen's Compensa- WORK NOTED ti n Id tp(pnce. I NSPECTION DEPARTMENT SIG AT E (eWNER OR AG DATE SIGNED CITY OF EDMONDS MINNOW I ATTENTION 771-3202 IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBC CHAPTER 3. 102-87 6AY4ely 11. VALUATION FEE ENE am APPLICATION APPROVAL This application is not a permit until signed by the Building Official or his Deputy; and fees are paid, and receipt is acknowledged in space provided. OFFICIAL'S SIGNATURE DATE RELEASED BY: DATE ORIGINAL — File YELLOW — inspector PINK — Owner GOLD — Assessor cr Uj 4 3: Z Z 0 Z M CHEMMts Ppa7BCT iwe: '�IrNW44M (OWST PMTXT ADDRESS: APPLICATION RECEIPT DATE: 7-ZJ -*? /57': Revi PIANNING WrR/SWR STREEr BUILDIWG SINGLE FAMILY/MMT=/CaMMERCIAL - (Circle One) TIRE. /T/-//-/T/7 SETBACKS CHECKED - Planning 2y1111111 VARLAIXE/SF TPACK ADJ. TTFITR7 77Tf17TM C(MITIONAL USE PEMIT /7//77----7— / TF1 -IITI-7 7-/T/ 7T7 -77-7 -7/r/ ADB REQUIRDENITS CHECKM 7 T1 7 7 777T777-77 T//-/,r! -77 7 7 7 —77 i 7-1 7TT177 OTHER ZONING REQUIREMENTS 77MT/7- / T77777777 4 ENVIRONMEMMI, FEATURES 777-777 7777-77-7�7/ % 17%1�1�171 11111114 7777W 'V=S SLOPF & VEHIC!Lr ACCESS 7777T717 -)RAINAM' PLAN (On Site) Ap_,y �C/41,7'- T/7 7-7 7-77 77/T/7 TR H T1 7 TTFITI -77 .Fr.AL DESCRIPTION VFRTFICAT )OTT CIATM/DF:DTCATI()NS '777771W 10 ASEMENr - 11UBT,TC/PRTVATr4 ,Oer D14 77771-777 //1/// 71111 771 1111-17777 'Alf -"ATE SFWLR CONNECTION IF NO LID# ////// ///////// ///////// 11111177 //////// 1 12 TAT/SUBDIvISIoN REQUTREMUM 777777 — -177777TI7 77T/T/-// 13 :TCJFP--OP-WAY CONSTRUCTION PERMIT PFf-D' 77TR7 ////// 711111-17T ///////// 777777777 ///////// 14 a4D REM MR PUBLIC IMPROVEMENTS -17-11--1777T777TI7777 15 ;OTLS CONDITIOtIS & GROLND !'ATER FIErp ofayED 16 7/7777777 '777TI7777 JREET PAVING3 REQUIRED ///////// ///////// 1 17 :REQUIRED T/ f T/ ITITR7 T7TITI F7 IMB AND GUT-FER -ITTI-IT177 18 JDFWAU IUMIRED "ff ////// ///////// 7 7 7 7 7 7 / 7 7 ///////// 19 111117 17T77T177777T17R7-- URR CUP M-R DRIVE -WAY RECI) ///////// ///////// 20 '171EEP 7IW17IT7711111177 1111111711 -. NAME SIGN REC)D 21 IMER SIGNING RE)M ---7TF17-1T1T17TR 77TR7 777TIT717 111771-IT17 -- 22 rDE SEWER AVAIIARILITY //////// 23 XISTING WrER MATN SIZE 17777TI77 111111117771111111 24 IMM P0M SIZE. UIT11 177111117 25 "31VICF LrNE SIZE TITIff T fn7l- 11�7 1777 7111777777777 - //////// 26 eDRANT REQUIRED 11111117-1-7TMT177 ///////// 7777/77777 27 MRANT SIZE EXISTING 77 1-1-1-ITM -7TFITF17T7 - 20 C&S CUqNECTION INSPECTION REOD /,f/-U 777777777 A 1111-17777 - 29 �TEM MER 0 UU�M REM ////// 30 FIRE LINE CHARGE REQD,- SPRINKLER 7777 TTF1 7 31 Mm cur 32 IEN DITCH EXISTING 177111 JV/ -- 33 117111 777777777777777T/7 REOD ---Tl7TR 4//7/-/T/-/ 34, ILVE3Zr REOD ////// ///////// 11771711-1 ///////// 1 35 SIZE 7T/-//7 36 ,TCH BASIN REQD 777717TIT 37 7= INDICA"M ON SITE PLAN ////// 771-f"77T //R 38 (OULDER DPAINAGE MAIMMIN 777777 17RTUT11711111111 SHALE OPFN RUNOFF ////// Q 39 'SC: T[77FI7771-111111111 - -T — 40 VIEWED BY: PLANNING MGINEE I RING I MIGR. PUB12C WORKS GR MEMO TO: Building Division FROM: Engineering Division /7"& SUBJECT: After review of the subject building permit application, we have the following comments: I ) Connection to City water system required. 2) Connection to City sanitary sewer system required. 3) Right-of-way permit required for any work on City property. 4) Driveway slope not to exceed 1419. 5) Back water valve required if downstairs plumbing is below elevation of upstream manhole. 6) Water and sewer lines to be separated by 10 foot minimum. 7) Builder/owner responsible fo?,containino all temporary runoff and I erosion on site and may not iriipact neig�boring properties in a*ny way. 8) Construction hours from 7:00 a to 10:00 pom. on we�ekdays and 10:00 a.im. to 6:00 p.m. on weekends and holidays. 9) No burning of construction refuse by Eire Dept. .9 FL,� . f:::� 1-4 PARCEL #: 00757200000600 LEGAL DESCRIPTION: 'kREAJ,, 8! STEELE PARK BLK 000 D-00 LOT 6 7 g AO ,�O'RTH SITE PLAN NOT TO SCALE PILE INFORMATION PIER NUMBER DESIGN LOAD (LBS) PIER NUMBER FDESIGN LOAD (LBS)j PIER NUMBER DESIGN LOAD (LBS) 1 3982 14 27 2 3982 15 28 3 6969 16 29 4 6969 17 30 5 6969 18 31 6 5973 19 32 7 5973 20 33 8 5973 21 34 9 22 35 10 23 36 11 24 37 12 25 38 13 26 39 STRUCTURAL NOTES GENERALNOTES . . . ....... 1. DESIGN CODES: IBC'09, IRC'09 1. PIERS TO BE INSTALLED ACCORDING TO THE PUSH PIER INSTALLATION NOTES. z z 2. FLOOR LOADS: DL=10 PSF, LL=40 PSF 2. THE LOCATIONS AND DIMENSIONS ON THIS DRAWING ARE BASED ON MEASUREMENTS TAKEN WITH A a 3. 4. ROOF LOADS: DL=25 PSF, LL=25 PSF (SNOW) PIER CAPACITY: TAPE MEASURE AND ARE RELIABLE FOR THE PURPOSE OF REPAIRING THE FOUNDATION FOR THE � 0� 16,500 LEIS ALLOWABLE RESIDENCE. THIS DOCUMENT IS NOT A LEGAL SURVEY OF THE PROPERTY. 5. MATERIALS (IF UISED): 3. THE CONTRACTOR IS RESPONSIBLE FOR: w 5.1. STEEL TUBE" ASTM A513 (FY, MIN=70 KSI). 3.1. VERIFICATION OF SITE CONDITIONS, INCLUDING DIMENSIONS AND EXISTING CONDITIONS OF THE w 5.2. STEEL ANGLE SECTIONS" ASTM A36 (FY, MIN 36 KSI) STRUCTURE. E9 5.3. STEEL PLATE: ASTM A36 (FY, MIN 36 KSI). 3.2. SITE SAFETY AND WORKER PROTECTION. Z i 5.4. CONCRETE: FC=3000 PSI (28 DAY). 3.3. FOLLOWING ALL LAWS AND REGULATIONS RELATED TO THE PROJECT. w 5.5. QUICK SET MORTAR=5000 PSI (28 DAY). 3.4. LOCATING UNDERGROUND AND OVERHEAD UTILITIES. Z. 6. THE CONTRACTOR IS RESPONSIBLE FOR: 4. THE CONTRACTOR & OWNER SHALL REFERENCE THE ORIGINAL SIGNED PROPOSAL FOR THE SCOPE a 6.1. VERIFICATION OF SITE CONDITIONS, DIMENSIONS, AND OFF ALL ITEMS IN THE PROJECT THAT MAY OR MAY NOT BE SHOWN IN THISPIER LAYOUT DRAWING. z EXISTING CONDITIONS OF THE STRUCTURE. THESE ITEMS MAY INCLUDE (BUT IS NOT LIMITED TO): E9 z 6.2. SITE SAFETY AND WORKER CONDITIONS 4.1. TEMPORARY RELOCATION OF ITEMS (DECK BOARDS, LANDSCAPING, ETC) FOR ACCESS TO THE w IZ 6.3. FOLLOWING ALL LAWS AND REGULATION RELATED TO FOUNDATION. w THE PROJECT. 4.2. WORK ITEMS THAT DO NOT REQUIRE A PERMIT (CONCRETE PATCHING, CRACK FILLING, ETC). z w z 6.4. LOCATION UNDERGROUND AND OVERHEAD UTILITIES. 0 z W FOUNDATION L4 WALL j ,A E= P" 7" OV` ED City of Edmonds Building Department ...4 -1 PUSH PIER INSTALLATION INSTRUCTIONS (BASED ON INSTRUCTIONS PROVIDED BY THE GRIP-TITE COMPANY) N P`;"!T1v L A ��rfi u Q, B TRIM PORTION E FUR 1. LOCATE ALL EXISTING UNDERGROUND AND OVERHEAD UTILITIES AT THE LOCATIONS OF THE PROPOSED PIERS CRAWL SPACE �101- ANL) L)�w'tjfJA(3E TO DETERMINE WHETHER THERE IS CONFLICT. OF FOOTING TO 2. EXPOSE THE FOUNDATION AND FOOTING AT THE PROPOSED PIER LOCATIONS, TO A DEPTH OF 6 INCHES BELOW 0 THE BOTTOM OF FOOTING. FIT BRACKET 3. PLACE FIRST PIER NO FURTHER THAN 2 FEET FROM THE CORNER, AND DEPENDING ON THE CONDITION OF THE FOOTING AND/OR THE WEIGHT OF THE STRUCTURE, PLACE PIERS EVERY 2 FEET TO 6 FEET ON -CENTER. THE UNDER WALL ENGINEERING DIVISION 205 Park Central East Ste 412 PIERS, HOWEVER, SHOULD NOT BE PLACED MORE THAN 6 FEET APART. IF THERE ARE CRACKS IN THE FOOTING, �R 0 AS NOTE SPRINGFIELD, MISSOURI 65806 PLACE A PIER UNDER EACH CRACK. 417-831-5550 ph Date: 4 AFTER EXPOSING THE FOOTING, CLEAN OFF ALL FOREIGN MATERIAL FROM THE TOP OF THE FOOTING IN THE 417-831-5551 fax AREAS WHERE THE PIERS ARE TO BE INSTALLED. DRILL 3/8-INCH HOLES THROUGH THE FOOTING FLANGE ABOUT M.S. Murphree-Roberts, Registered Professional Engineer, Lic. No. 47934 3/4-INCH AWAY FROM THE STEM WALL USING A ROTARY HAMMER DRILL. DRILL THE HOLES EVERY TWO INCHES hfeorders@haymanengineering.com ALONG THE FOOTING FLANGE FOR A TOTAL LENGTH OF 18 INCHES. AT THE END OF THE SECTION OF CONCRETE WORKING TRENCH TO BE REMOVED, DRILL 3/8-INCH DIAMETER HOLES EVERY TWO INCHES ALONG A LINE PERPENDICULAR TO THE STEM WALL TO THE OUTSIDE EDGE OF THE FOOTING FLANGE. 5. AFTER COMPLETION OF THE DRILLING, BREAK OFF THE 1 B-INCH LONG SECTION OF CONCRETE THAT WAS 4' ISOLATED BY THE DRILLED HOLES. \> ur 6. SMOOTH THE JUST -BROKEN VERTICAL FACES OF THE CONCRETE USING APPROPRIATE TOOLS SO THAT THE (0 sk FOUNDATION BRACKET FITS FLUSH AGAINST THE FOOTING. ENSURE THAT THE FRONT OF THE FOOTING IS FLAT AND NOT TAPERED IN EITHER DIRECTION. njCC4�6 wr BRACKET 7. REMOVE THE SOIL FROM BENEATH THE FOOTING TO A DEPTH OF ABOUT SIX INCHES. THOROUGHLY CLEAN THE V, FOOTING WHERE THE BRACKET IS TO BE INSTALLED. VERIFY THAT THE BOTTOM OF THE FOOTING IS LEVEL SIDE TO SIDE AND FRONT TO BACK. MAKE THE BOTTOM OF THE FOOTING LEVEL IF IT IS NOT LEVEL UTILIZING HIGH A 2'-011 21-Of STRENGTH GROUT OR SIMILAR MATERIAL. 9/12/13 8. POSITION THE PIER BRACKET INTO THE RAM CYLINDER ASSEMBLY NOTCH AND SECURE IT IN PLACE WITH CRIBBING BENEATH THE PIER BRACKET. CONNECT THE HYDRAULIC RAM TO THE HYDRAULIC PUMP. CONNECT A atf z CALIBRATED HYDRAULIC PRESSURE GAUGE BETWEEN THE RAM AND THE PUMP. ENGAGE THE HYDRAULIC RAM L-i 0 UNTIL THE DRIVE CYLINDER HEAD IS TIGHT AGAINST THE STARTER TUBE. flo E 0 z U) 3:0 9. BEGI N MONITORING THE FOUNDATION MOVEMENT AS THE PIERS ARE ADVANCED TO THE LOAD BEARING < 00 c:) 0 V) uj => U) STRATUM. DO NOT EXCEED 4200 PSI (40,000 LBS) ON THE HYDRAULIC RAM (OR EQUIVALENT PRESSURE EQUAL TO v- U5 40,000 LEIS DEPENDING ON THE GAGE CALIBRATION). ADDITIONAL TUBES ARE ADDED BY SLIDING THE ADDED < E 11711 UJI FENCE TUBE INTO THE COUPLING ON THE JUST -INSTALLED TUBE. ADVANCE THE ADDITIONAL TUBES IN THE SAME (D 2 PIER SHAFT: SEE NOTES MANNER AS THE STARTER TUBE. THE CRIBBING UNDER THE BRACKET MUST BE KEPT TIGHT WH LE ADVANCING cn C/) 75 S1 I THE PIERS (TUBES). IF MORE THAN ONE HYDRAULIC PUMP IS BEING USED, DO NOT PUSH TWO ADJACENT Lij PIERS AT THE SAME TIME. THIS MAY RESULT IN A FALSE LIFT WHILE PUSHING THE PIERS TO THE LOAD BEARING _j CD 0 STRATA. CD C-4 10. RAISE THE FOUNDATION UNTIL IT TOUCHES THE SILL PLATE AND THEN CONTINUE TO ADVANCE THE DRIVE TUBES z @3 cu C14 UNTIL THE SUITABLE BEARING STRATUM IS REACHED. X ui co Z 0 u) 11. SUITABLE BEARING STRATUM IS DEFINED BY A FORCE EQUAL TO 40,000 LBS OR UNTIL AN APPROXIMATE LIFT OF =3 1/4 INCH OF THE STRUCTURE IS ACHIEVED. THE LOAD MUST BE HELD FOR 5 MINUTES WITHOUT 114 INCH OF < 0 4- CN VERTICAL MOVEMENT OR ANY HYDRAULIC PRESSURE DROP. IF THE PIER SETTLES 1/4 INCH OR THE PRESSURE cq C:) U) DROPS, ADD ADDITIONAL PRESSURE TO THE PIER UNTIL THE 5 MINUTE HOLD TEST IS ACHIEVED. AT COMPLETION U) .4 PIER DETAIL r2 OF A THE SUCCESSFUL 5 MINUTE HOLD, RECORD THE GAGE PRESSURE ON7HE PIER LOG AND THE PIER WILL BE z CONSIDERED INSTALLED. -.0 SCALE.- J14yp 1p-O)p - C-4 2 12. A MINIMUM OF 10% OF THE PIERS SHALL BE TESTED AS FOLLOWS. FOR EACH GROUP OF 10 PIERS, THE FIRST 11,,� �, U) j PI PIER INSTALLED SHALL BE CONSIDERED THE TEST PIER. THE PIER SHALL BE INSTALLED IN 18" INCREMENTS, 00 'PuSF SECTION 00 ZD c:) RECORDING THE HYDRAULIC GAGE PRESSURES ON THE GRIP-TITE PUSH PIER PRESSURE LOG AT EACH CHIMN ZY) �jll INCREMENT. CONTINUE THE INSTALLATION UNTIL THE PIER MEETS THE REQUIREMENTS OF INSTRUCTION #11. 0 CID EY c NTRAC ,OR/TO PLACE A CERTIFIED CALIBRATED LOAD CELL IN -LINE WITH THE HYDRAULIC RAM AND RECORD THE FINAL PIER T ".I 0� LL J0 5 %EMOVE/REPLACE LOAD ON THE LOG. VERIFY/DETERMINE THE HYDRAULIC GAGE FACTOR BY DIVIDING THE LOAD CELL FORCE BY C C RAMIC/CONG\ THE ASSOCIATED PRESSURE GAGE READING. STE�PSAF NEEDED\v 13. THE ALLOWABLE PIER CAPACITY IS CALCULATED AS 50% OF THE MEASURED FORCE AS LOGGED OR 16,500 LBS T E PIERS DETAIL VARIES DEPENDING (MAXIMUM PER MANUFACTURER). 14. ONCE THE PIER IS INSTALLED, PREPARE THE TUBE SO A GRIP-TITE CAP CAN BE PLACED ON THE TUBE TO ON LOCATION OF PIERS PREPARE FOR LIFTING. THERE MUST BE A MINIMUM OF 6-1/2 INCHES OF TUBE PRESENT ABOVE THE TOP OF THE DOORWAY BRACKET. SUN, OOM -TITE REINFORCEMENT INSERT -TUBE INTO THE LAST PIER TUBE. CUT THE REINFORCEMENT 15. INSTALL THE GRIP INSERT -TUBE 3 INCHES SHORTER THAN THE DISTANCE FROM THE TOP OF THE PIER TO THE COUPLER TO ALLOW THE CONTRACTOR IS' AN ADDITIONAL TUBE TO BE INSTALLED LATER. C.0 16. REMOVE THE HYDRAULIC RAM AND REPEAT THE ABOVE STEPS FOR THE REMAINING PIERS, DOCUMENTING THE RESPONSIBLE TO REPLACE w c\I FINAL DEPTHS AND GAGE PRESSURES FOR EACH PIER. CRAWLSPACE FOUNDATION FOOTPRINT C) 17. INSTALL THE GRIP-TITE PIER CAP AND BOLTS TO THE TUBE AND BRACKET. PLACE THE CAP ON TOP IF THE TUBE. 00 11>< ANY CERAMIC TILE/ INTERIOR PARTITIONS ABOVE NOT SHOWN z U) IF A GRIP-TITE LIFT CYLINDER IS BEING USED TO LIFT, THEN 1-1/2 TO 2 INCHES OF THE BOLT MUST BE EXPOSED Cy) ABOVE THE NUT ON TOP OF THE CAP SO THAT THE LIFT CYLINDER CAN BE ATTACHED. IF A GRIP-TITE HYDRAULIC CONCRETE THAT IS, REMOVED w RAM IS BEING USED TO LIFT, ABOUT 1/4 -INCH OF THE BOLT MUST BE EXPOSED ABOVE THE NUT ON TOP OF THE n CAP. ONCE THE CORRECT AMOUNT OF BOLT ABOVE THE NUT IS EXPOSED, RUN THE BOTTOM OF THE NUT UP SUNROOM IN ORDER TO PLACE PIERS HAND -TIGHT AGAINST THE BOTTOM OF THE BRACKET. TIGHTEN THE BOLTS EVENLY SO THAT THE CAP STAYS LEVEL. .14 18. WITH THE CAP IN -PLACE AND THE BOLTS TIGHTENED, THE LIFT CYLINDER MAY BE INSTALLED. TO INSTALL THE w U') CRAWL LIFT CYLINDER, SET IT ON THE CAP WITH THE CENTER OF LIFT -CYLINDER IN CENTER OF THE RAISED WELDED CIRCLE ON THE CAP. SCREW THE COUPLER ON THE BOLT THAT IS ATTACHED TO THE LIFT CYLINDER TO THE ry. z 6 BRACKET BOLT THAT IS STICKING UP THROUGH THE CAP. SCREW THE COUPLER ON THE LIFT CYLINDER BOLT 9 UNTIL IT BOTTOMS OUT ON THE BRACKET BOLT. THE NUT ON THE TOP OF THE CAP MAY NEED TO BE ADJUSTED 0 FOUNDATION TO MAKE SURE THAT THERE IS ENOUGH THREAD FOR THE COUPLER TO BE COMPLETELY SCREWED ONTO THE 7 BRACKET BOLT. THE COUPLER ON THE LIFT -CYLINDER -BOLT SHALL BE SCREWED ONTO THE LIFT CYLINDER BOLT 0 r) WALL,,- SO THAT THE TOP NUT ON THE BRACKET BOLT IS RESTING ON THE CAP. ADJUST THE NUT ON THE BOTTOM OF THE BOTTOM OF THE BRACKET. FINALLY, TIGHTEN THE NUT ON TOP 9 SECTION uj 2� (D PUSH PIER THE BRACKET BOLT SO IT IS TIGHT AGAINST OF THE LIFT CYLINDER. IF A HYDRAULIC RAM IS BEING USED TO LIFT, THE HYDRAULIC RAM ONLY NEEDS TO BE co 8 REATTACHED TO THE BRACKET. T -n %j 19. ONCE A LIFT CYLINDER OR HYDRAULIC RAM HAS BEEN PLACED ON EACH PIER, CONNECT THE HYDRAULIC HOSES TO EACH OF THE LIFTING DEVICES IN SERIES. 9 20. OPEN THE CONTROL VALVE ON THE LIFTING DEVICE CLOSEST TO THE PUMP. WITH THE PUMP CONTROL VALVE IN THE DRIVE POSITION, USE THE PENDANT CONTROL TO PRESSURIZE THE DEVICE TO 1,000 PSI. CLOSE THE VALVE X/ CONTRAC)77OR TO ON THE FIRST LIFTING DEVICE AND OPEN THE CONTROL VALVE ON THE SECOND LIFTING DEVICE. USE THE PENDANT (',ONTROL TO PRESSURIZE THE SECOND LIFTING DEVICE TO 1,000 PSI. CONTINUE THIS PROCEDURE E/REPLAC\ REMOY/ E UNTIL ALL OF THE LIFTING DEVICES HAVE BEEN PRESSURIZED TO 1,000 PSI MAKING SURE TO CLOSE ONE WORKING TRENCH SHRUBS\IF NEEDED CONTROL \/ALVE BEFORE OPENING THE NEXT ONE. K TO PjLAc IERS/ COPYRIGHT HFE 2013 21. ONCE THE HYDRAULIC PRESSURE TO EACH LIFTING DEVICE IS SET AT 1,000 PSI, THE STRUCTURE MAY BE LIFTED. THESE PLANS ARE COPYRIGHTED OPEN ALL THE VALVES AT EACH LIFTING DEVICE AND APPLY PRESSURE. AFTER THE STRUCTURE HAS BEEN AND ARE SUBJECT TO COPYRIGHT CERAMIC PROTECTION UNDER SECTION 102 OF 7 LIFTED TO THE DESIRED LEVEL, CLOSE THE CONTROL VALVES ON ALL OF THE LIFTING DEVICES. NEXT T GHTEN PAT'10 TILE THE COPYRIGHT ACT OF 1990. THE FOUNDATION: ALL OF THE NUTS ON THE TOP AND BOTTOM OF THE BRACKET, WHICH WILL HOLD THE FOUNDATION IN PLACE. PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS DISCONNECT THE LIFTING DEVICES AND REMOVE THE EQUIPMENT FROM THE EXCAVATIONS WELL AS THE ARRANGEMENT AND TRIM PORTION BRACKET 22. BACKFILL THE EXCAVATIONS WITH THE EXCAVATED MATERIAL IF THE MATERIALS ARE SUITABLE. IN LANDSCAPED COMPOSITION OF THE SPACES AND ELEMENTS OF THE DESIGN. AREAS, PLACE THE SOIL IN LOOSE LIFTS NO GREATER THAN 12 INCHES IN THICKNESS. COMPACT EACH LIFT TO A UNAUTHORIZED USE OF THESE PLANS CAN LEGALLY RESULT IN THE OF FOOTING TO FIRM AND UNYIELDING CONDITION BEFORE PLACING SUBSEQUENT LIFTS. COMPACTION SHOULD BE PERFORMED CESSATION OF CONSTRUCTION OF L/4 BY A MANUALLY OPERATED, UPRIGHT COMPACTOR GENERALLY REFERRED TO AS A JUMPING JACK. THE PROJECT BEING SEIZED AND/OR FIT BRACKET MONETARY COMPENSATION TO HAYMAN ENGINEERING. UNDER WALL 'K PROJ. NO. CITY OF E APPROVED BYL PLMNING HE13090007 PIER SHAFT: SEE NOTES DRAWN OLD UILDING �')E M11 PA, DATE Wor, 09/12/13 Ar)DRESS REVISIONA 0 I f_L 13 APPROVEIDL)KFE- /7 DWG. NO. BLI 3. OFFIC1. Aer NORTH PIER DETA IL kL RFEECHVE- 3 (73 PERMT Rk.H01MBER SCALE.- 314)0 0-0y) FOUNDA TION PLAN SEP 16 2013 1B S1 SCALE.- 114pp 1'-0" DEVELOPMENT SEIRIAGES C FOUNDATION PLAN AND Oily, OF EDMONDS DETAILS