Loading...
00981September 12; 1978 Pl MEMO TO: anning,Division FROM: Fred F. Herzberg City.Engineer SUBJECT: PRD-3-78 - DAVID KINDERFATHER In reviewing the grading shown on the plot plain, I am concerned about three areas: 1. Excessive slope of driveway to single unit on east side. 'Fourteen percent is maximum allowed without variance. Fifty percent is shown. 2. Although the trees are noted as'"retained" and "contoursaroundtrees undisturbed"$ it is very easy to kill a tree by disturbing the * root system or. altering grade such that normal runoff will remove the soil from the crown. This should be especially watched near the knoll on the east of the develop 5 ment. 3. At the northeast corner of the triplex there is a 45 degree slope shown. The soil may not be stable at this slope without artificial restraint. The environment assessment indicates that all storm water runoff will be diverted directly to Shell Creek. This would be satis factory if the proposed retention basin in Yost Park was a reality'. Unfortunately it does not exist. Therefore a closed, on site retention system will be required as defined in Ordinance #1924. FFR.; gl