01169CITY OF EDMONDS
ENGINEERING REQUIMtENTS FOR PLATS AND SUBDIVISIONS
NAME
WISPY WILLOWS
FILE N0. P-8,78
HEARING DATE 4-12 - 7 8
PRIOR TO PRIOR D - BONM COriPLE'I'ED
POSTED
'.r
RECORDING BLDG PERMIT
'
1.
1,
Right-of-way:
40 foot dedication required on access
'
street with 40 ft. R. cul-de-sac
X
2.
P vi g and Curbs: 2.
2a/+ oot curbed pavement on access
X
road.
3.
Turn Around:
3.
30 foot radius curbed cul-de-sac
X
4.
Sidewalks &.Planting Strip:
4.
Not required
X
S.
Access Easements:
S,
Not applicable
X.
6.
Water Mains:
6.
-
6" main required in proposed cul-de-sac
.
X
i
7.
Fire Hydrants:
7,
As required per Fire Department
X
8.
Sewers or Septic Tanks:
8•
{
Connection to sanitary sewer required
X
9. Drainage: Install all necessary storm sewers
and drainage facilities per ordinance 1924 u
approved drainage plan. Where drainage s, across ri
property, ' all parties having any ownersip inter
in the lands being platted shall provide, as a
restriction on the plat rumning with the land,
that the City of Edmonds shall be held harmless
from any and all,claims for damages which may be
occasioned to adjacent land by reason of the
construction and operation of the drainage system,
it