Loading...
01327m Y S N r I f 114 5TH AvE. N. 1 PRospEar 6.1107 Edmonds Planning Commission City Hall Edmonds, Washington Re: Proposed Plat Franich Addition Gentlemen: The subject Plat has been carefully reviewed by the undersigned, and after extensive research, recommendation is regretfully made that this preliminary plat be disapproved in its present form and returned to the developer for restudy. This recommendation is made based on the fact that as of March 21, 1960, 55 to 60% of this area was saturated, and percolation tests could not be made. In the west half of this Plat, the water table was 6" to 10" from ground surface. In the northeast portion, water was found at 33" from ground surface. Only in the southeast portion, which is the highest portion in elevation, were perc tests made satisfactorily. The perc- olation rate in this area was about 8 minutes/inch. All of this is due to the natural drainage through this region. Surface water from the north comes across this property. The property on the south side of 218t does not drain off the water except during very heavy rains. Even if the low area of the subject plat were filled to an elev- ation equal to that on the south, nothing would be accomplished until the following conditions were improved upon: (1) A good drainage course established along the west property line. (2) The culvert under 218th relocated in line with the drainage course and sized to take the load of heavy rainfall.