040909 thru 041409_FieldReport_AES.pdfV VA "I Oki 4 as] MA - I
Associated Earth Sciences, Inc.
0 0 Tt %EC4VED
911 Fifth Avenue, Suite 100
Kirkland, Washington 98033
425-827-7701 FAX 827-5424 APR 2 3 2009
TO: Sunset 100 Urnited Partner INEERING DIV1,S)ON
c/o Real Estate Capital U,C
16118 72 A Avenue West, Edmonds, WA 98026
ATTN: Mr. John Thorsen
AS REQUESTED BY Mr. Duane Landsverk
THE POLLOWING WAS NOTED
Page I of 2
Date
Project.Name
�unset
Project No.,.04-09-09
Embedment
121
KE080112213
Location
Weather
121 Sunset Ave, Edmonds, WA
50OF
MUniCipality
_9vercast,
Report NUMI'
City of Edmonds
10
Elngineer/Architect
2.76
-.C.&. G Engineering
75
client/owner
24
SUSET 1001 znited Partnership
37
General
3.00
Duane Landsverk
62
Pile Coiitt-actor/SLuI)Cl'illtciideiit
20
McDowell Pile King _/ Matt
32
AESI arrived on site to perform construction monitoring activities associated occurring on site today. Out- presence was requested
by Mr. Ron Skinner on behalf of 1,andsverk Quality Homes (I,Qfl) to observe site conditions prior to Auger Cast (AC) pile
installation.
Atigercast Piles
McDowell used a crane with a 70 foot boom able to support the AC pile installation drill with an 18 inch diameter di-iH capable of
drilling to a depth of 40 feet, A total of I I AC piles were installed today; all piles were note to be at least 5 pile diameters apart to
prevent piles from blowing out into each other. Piles ranged in depth from 27 to 37 feet with embedment depths of 12 to 27 feet.
The tipper 15 feet of soil on the site was noted to be loose organic soil and fill that is unsuitable for a typical building foundation.
The stable soils below the loose soil consisted of hard silty sand with gravel. Once drilling was complete 4000 psi. concrete was
placed through the shaft of the AC pile drill to the bottom of the boring. The piles were installed allowing for 9 to 17 feet of head
for the concrete above the base of the drill. Next rebar cages and center bars made of 6 or 8 bar rebar were installed into the
borings, 6 bar for 25 foot piles and 8 bar for 30 and 35 foot piles. The center bar extended to the full length of the piles and the
rebar cage only extended to a depth of 22.5 feet. See table below for a summary of piles completed today. See page two For a map
of the piles completed today,
Erosion
The contractor has a small section in the northwest corner of the site where the slope to the neighboring property is over -
steepened. This section along with all the other slopes have been covered with plastic and no significant changes it) the slope
conditions were noted today.
Pile#
Pump
Counts
Depth of Bearing
Embedment
Embedment
Spec.
Total
Depth
Concrete
Head
CY
used
74
69
10
27
20
37
10
2.76
73
75
13
24
20
37
10
3.00
72
62
12
20
15
32
10
2.48
53
66
14
18
15
32
12
2.64
3,6
60
15
17
15
32
10
2.407
69
73
13
24
20
37
12
2,92
67
56
13
14
10
27
10
2.24
64
63
53
81
12
14
15
23
10
20
27
37
9
17
2.12
3,24
66
55
15
12
10
27
14
2.20
60
54
14
13
10
27
10
2.16
COPIES TO: FIELD Rr:,P,: Michael Place P.E.
DATE
APR 2 : Druce Blyton 13,
MAILED: PRINCIPAL PMBBlP07... —
FIELD REPORT
Associated Earth Sciences, Inc.
911 Fifth Avenue, Suite 100
Kirkland, Washington 98033
425-827-7701 FAX 827-5424
TO: Sunset 100 Limited Partnership
c/o Real Estate Capital LLC
16118 72" Avenue West, Edmonds, WA 98026 —
ATTN: Mr. John Thorsen
AS REQUESTED BY Mr. Duane Landsverk
THE FOLLOWING WAS NOTED:
Page 1 of 3
Date
I Project Name
Project No.
04-10-09
unset 121
KE080122B
Loeation
weather
121 Sunset Ave, Edmonds, WA
Overcast, 500E
Municipality
Report Numbu
City of Edmonds
1 ]
Lnoineer/Architect
C & G Engineering
Client/owner
SUSET 100 Limited Partne�
Gencral ContractorlSuperintendent
Duane Landsverk
Pile ConU'aCor/SuperinteFtdent
McDowell Pile King I Matt
AESI arrived on site to perform construction monitoring activities associated occurring on site today. Our presence was requested
by Mr. Ron Skinner on behalf of Landsverk Quality Homes (LQH) to observe site conditions prior to Auger Cast (AC) Pile
installation.
Augereast Piles
McDowell used a crane with a 70 foot boom able to support the AC pile installation drill with an 18 inch diameter drill capable of
drilling to a depth of 40 feet, A total of 21 AC piles were installed today; all piles were note to be at least 5 pile diameters apart to
prevent piles from blowing out into each other. Piles ranged in depth from 27 to 37 feet with embedment depths of 12 to 23 feet.
The upper 11 to 15 feet of soil on the site was noted to be loose organic soil and fill that is unsuitable for a typical building
foundation. The stable soils below the loose soil consisted of hard silty sand with gravel. Once drilling was complete 4000 psi
concrete was placed through the shaft of the AC pile drill to the bottom of the boring. The piles were installed allowing for 9 to 17
feet of head for the concrete above the base of the drill Next rebar cages and center bars made of 6 or 8 bar rebar were installed
into the borings, 6 bar for 25 foot piles and 8 bar for 30 and 35 foot piles. The center bar extended to the full length of the piles
and the rebar cage only extended to a depth of 22.5 feet. See table on page two for a summary of piles completed today. Sce
page three for a Wrap of the piles completed today.
Erosion
The contractor has a small section in the northwest corner of the site where the slope to the neighboring property is over -
steepened. This section along with all the other slopes have been covered with plastic and no significant changes in the slope
conditions were noted today.
COPIES TO:
FIELD REP
DATE PRINCIPAL / PM
MAILED: P 7 0
Michael Place P.E. '
Bruce Blyton P.E. ,
.,. r
'(91
KE -080122 4-10-09 page 2 of 3
Pile #
Pump
Counts
Depth of
Bearing
Embedment
Embedment
Sec.
Total
Depth
Concrete
Head
CY Concrete
used
62
54
13
14
10
27
10
2.16
58
50
12
14
10
27
10
2.00
56
53
11
16
10
27
10
2.12
57
67
14
18
15
32
15
2.68
40
81
15
22
20
37
13
3.24
55
78
14
23
20
37
15
3.12
39
82
15
22
20
37
11
_
328
20
84
15
22
20
37
11
3.36
41
61
15
12
10
27
10
2.44
45
64
15
17
15
32
10
2.56
44
76
15
22
20
37
13
_
3.04
25
65
15
17
15
32
15
2.60
27
81
15
22
20
37
10
3.24
10
73
15
17
15
32
11
16
80
15
17
15
32
11
--2.92
3.20
48
80
15
22
20
37
13
3.20_
47
56
15
12
10
27
11
51
77
15
22
20
37
13
_2.24
3.08_
50
71
15
17
15
32
11
2.84
30
59
15
17
15
32
9
2.36
46
51
15
12
10
27
5
_ 2.04
Associated Earth
0 0
911 Fifth. Avenue, Suite 100
Kirkland, Washington 98033
425-827-7701 FAX 827-5424
FIELD REPORT
Sciences, Inc.
TO: Sunset 100 Limited Partnership
n
c/o Real Estate Capital LLC
16118 72" Avenue West, Edmonds, WA 98026
ATTN: Mr. John Thorsen
AS REQUESTED BY Mr. Duane Landsverk
THE FOLLOWING WAS NOTED:
Page 1 of 3
Date
Project Name
Project No.
04-13-09
Sunset 121
KE0801228
Location
Weather
121 Sunset Ave, Edmonds, WA
Showers, 40°F
Municipality
Report Number
City of Edmonds
12
Engineer/Architect
C & G Engineering
ClientlOuner
SUSE`I' 100 Limited Partnershi
General Contractor/Superintendent
Duane Landsverk
Pile Contractor/Superintendent
McDowell Pile Kin / Matt
AESI arrived on site to perform construction monitoring activities associated occurring on site today. Our presence was requested
by Mr. Ron Skinner on behalf of Landsverk Quality Homes (LQH) to observe site conditions prior to Auger Cast (AC) Pile
installation.
Augereast Piles
McDowell used a crane with a 70 foot boom able to support the AC pile installation drill with an 18 inch diameter drill capable of
drilling to a depth of 40 feet. A total of 13 AC piles were installed today; all piles were note to be at least 5 pile diameters apart to
prevent piles from blowing out into each other. Piles ranged in depth from 27 to 37 feet with embedment depths of 17 to 22 feet.
The upper 15 to 17 feet of soil on the site was noted to be loose organic soil and fill that is unsuitable for a typical building
foundation. The stable soils below the loose soil consisted of hard silty sand with gravel. Once drilling was complete 4000 psi
concrete was placed through the shaft of the AC pile drill to the bottom of the boring. The piles were installed allowing for 10 to
15 feet of head for the concrete above the base of the drill. Next rebar cages and center bars made of 6 or 8 bar rebar were
installed into the borings, 6 bar for 25 foot piles and 8 bar for 30 and 35 foot piles. The center bar extended to the full length of
the piles and the rebar cage only extended to a depth of 22.5 feet. Pile operations were halted because the drive chain for the auger
broke while attempting to drill pile 38. The final two piles for this job will be completed tomorrow. See table on page two for a
suirunary of piles completed today. See page three for a map of the piles completed today.
Erosion
The contractor has a small section in the northwest corner of the site where the slope to the neighboring property is over -
steepened. This section along with all the other slopes have been covered with plastic and no significant changes in the slope
conditions were noted today.
COPIES TO: FIELD REP.:
DATE
MAILED: APR 2 9, _?__009- PRINCIPAL I PM
Michael Place P.E.
Bruce Blyton P.E.��'
KE -080122 4-13-09 page 2 of 3
Pile #
Pump
Counts
Depth to
Bearing
Embedment
Embedment
See.
Total
Depth
Concrete
Head
Concrete
used {CY)
49
76
15
22
20
37
10
3.26
9
77
1 15
22
20
37
10
3.30
15
58
15
17
15
32
10
2.49
31
69
15
22
20
37
15
2.96
14
71
15
22
20
37
13
3.04
7
63
15
22
20
37
15
2.70
12
63
15
17
15
32
11
2.70
11
60
15
17
15
32
11
2.57
21
71
15
22
20
37
10
3.04
17
63
15
17
15
32
10
2.70
13
61
15
17
15
32
13
2.61
18
62
15
17
15
32
15
2.66
37
74
15
17
15
32
10
3.17
38"
-
17
-
15
25
-
-
* Pile not completed today due to drive chain breaking,
*
PI(C ak,,5`jcf((e i'Vr�-'ic,Lis
Johl
6m I^'� aW ulry
d
;- -13= „
-3-13-
r
FIELD REPORT
Associated Earth Sciences, Inc.
0 n N
911 Fifth Avenue, Suite 100
Kirkland, Washington 98033
425-827-7701 FAX 827-5424
TO: Sunset 100 Limited Partnership
c/o Real Estate Capital LLC
16118 72°° Avenue West, Edmonds, WA 98026
ATTN: Mr. John Thorsen
AS REQUESTED BY Mr. Duane Landsverk
THE FOLLOWING WAS NOTED:
Pape 1 of 2
Date
Project dame
Project No.
04-14-09
Sunset 121
KE080122B
Location
Weather
38
Partly Cloudy,
121. Sunset Ave, Edmonds, WA
40O
Municipality
Report Number
City of Edmonds
13
Engineer/Architect
62
C & G Engineering
15
Client/Owner
27
SUSET 100 Limited Partnership
2.66
General Contractor/Superintendent
Duane Landsverk
Pile Contractor/Superintendent
McDowell Pile Kin 1 Matt
AESI arrived on site to perform construction monitoring activities associated occurring on site today. Our presence was requested
by Mr. Ron Skinner on behalf of Landsverk Quality Homes (LQH) to observe site conditions prior to Auger Cast (AC) Pile
installation.
Augereast Piles
McDowell used a crane with a 70 foot boom able to support the AC pile installation drill with an 18 inch diameter drill capable of
drilling to a depth of 40 feet. A total of 2 AC piles were installed today; all piles were note to be at least 5 pile diameters apart to
prevent piles from blowing out into each other. Piles ranged in depth from 27 to 37 feet with embedment depths of 12 to 23 feet.
The upper 13 to 17 feet of soil on the site was noted to be loose organic soil and fill that is unsuitable for a typical building
foundation. The stable soils below the loose soil consisted of hard silty sand with gravel. Once drilling was complete 4000 psi
concrete was placed through the shaft of the AC pile drill to the bottom of the boring. The piles were installed allowing for 5 to 10
feet of head for the concrete above the base of the drill. Next rebar cages and center bars made of 6 or 8 bar rebar were installed
into the borings, 6 bar for 25 foot piles and 8 bar for 30 and 35 foot piles. The center bar extended to the full length of the piles
and the rebar cage only extended to a depth of 22.5 feet. See table below for a summary of piles completed today. See page two
for a map of the piles completed today.
Erosion
The contractor has a small section in the northwest corner of the site where the slope to the neighboring property is over -
steepened. This section along with all the other slopes have been covered with plastic and no significant changes in the slope
conditions were noted today.
Pile
#
Pump
Counts
Depth to
Bearing
Embedment
Embedment
Sec.
Total
Depth
Concrete
Head
Concrete
used (CY)
38
61
17
15
15
32
5
2.61
54
62
13
15
10
27
10
2.66
COPIES TO:
DATE
MAILED:
APR 2 9, ?009
FIELD REP.: Michael Place P.F.
PRINCIPAL / PM: Bruce Blyton P.E. i" r_