0494 Magic Toyota Plumb Binder For Permit (Approved) (2).pdfPLUMBING — LEGEND
0
DIAMETER
ABV
ABOVE
DIRECTION OF FLOW
AD
ACCESS DOOR
0
SUPPLY OR RETURN ELBOW SECTION UP
AFF
ABOVE FINISHED FLOOR
AHU
AIR HANDLING UNIT
SUPPLY OR RETURN ELBOW SECTION DOWN
AP
ACCESS PANEL
SUPPLY OR RETURN TEE SECTION UP
BF
BELOW FLOOR
BOT
BOTTOM
v
SUPPLY OR RETURN TEE SECTION DN
CIP
CAST IN PLACE
EXISTING PIPING
CLG
CEILING
CONC
CONCRETE
HOT WATER RECIRCULATION PIPING
CONN
CONNECTION
HOT WATER PIPING
CW
COLD WATER
DIA
DIAMETER
COLD WATER PIPING
DN
DOWN
SANITARY WASTE PIPING
DWG
DRAWING
EA
EACH
— — —
VENT PIPING
EQUIP
EQUIPMENT
WASTE BELOW GROUND
FCO
FLOOR CLEANOUT
FF
FINISHED FLOOR
RWL
RAINWATER LEADER
FLR
FLOOR
ORWL
OVERFLOW RAINWATER LEADER
FOG
FATS, OILS AND GREASE
FT
FOOT OR FEET
iD
INDIRECT DRAIN
FUT
FUTURE
Ca
CONDENSATE DRAIN
GAL
GALLON
GALV
GALVANIZED
NP
NON -POTABLE COLD WATER
HP
HORSEPOWER
BALL VALVE
HT
HEIGHT
HVAC
HEATING, VENTILATION AND
—D4—
GATE VALVE
AIR-CONDITIONING
BUTTERFLY VALVE
HW
HOT WATER
HWSFU
HOT WATER SUPPLY FIXTURE UNITS
CIRCUIT SETTER
IBC
INTERNATIONAL BUILDING CODE
CHECK VALVE
ID
INSIDE DIAMETER
IE
INVERT ELEVATION
RELIEF VALVE
IMC
INTERNATIONAL MECHANICAL CODE
PRESSURE REDUCING VALVE
IN
INCHES
IN WG
INCHES WATER GAUGE
REDUCED PRESSURE BACKFLOW PREVENTER
LBS
POUNDS
LIN FT
LINEAR FOOT OR FEET
FLOOR DRAIN
MAX
MAXIMUM
ROOF DRAIN
MBH
1000 BRITISH THERMAL UNITS
PER HOUR
HOSE BIBB/WALL HYDRANT
MIN
MINIMUM
TP-o
TRAP PRIMER
MOCP
MAX OVER CURRENT PROTECTION
—� I-
MTD
MOUNTED
FLEXIBLE CONNECTION
NO
NUMBER
EXPANSION JOINT
N/A
NOT APPLICABLE
OD
OUTSIDE DIAMETER/DIMENSION
PORTABLE INSTRUMENT CONNECTION
PH
PHASE
STRAINER
POC
POINT OF CONNECTION
PRESS
PRESSURE
UNION
PSI
POUNDS PER SQUARE INCH
]
RPBP
REDUCED PRESSURE
/
PLUG AND/OR CAP
BACKFLOW PREVENTER
RPM
REVOLUTIONS PER MINUTE
PRESSURE GAUGE
SOG
SLAB ON GRADE
SBC
SEATTLE BUILDING CODE
THERMOMETER
SEC
SEATTLE ENERGY CODE
z
FLUSH CLEANOUT
SMC
SEATTLE MECHANICAL CODE
SL
SOUND LINED
MAVCR—
MANUAL AIR VENT
SQ FT
SQUARE FOOT OR FEET
SS
STAINLESS STEEL
AAV I i"
AUTOMATIC AIR VENT
TDH
TOTAL DYNAMIC HEAD
TYP
TYPICAL
UNO
UNLESS NOTED OTHERWISE
UPC
UNIFORM PLUMBING CODE
VTR
VENT THROUGH ROOF
W
WATTS OR WIDTH
W/
WITH
W/O
WITHOUT
WCO
WALL CLEANOUT
WG
WATER GAUGE
WSEC
WASHINGTON STATE ENERGY
CODE (AKA CHAPTER
51-11C WAC)
WSFU
WATER SUPPLY FIXTURE
UNITS
LEGAL DESCRIPTION
SOLNERS 5 ACRE TRACTS BLK 000 D-01- N 317 FT OF W 3 AC EXC E
20 FT THOF.
NE j OF THE NW j SECTION 29, TOWNSHIP 27N RANGE E4, W.M.
i�a�xe■HiYN �I,IPI�
THE PROPOSED PROJECT AT 21300 HIGHWAY 99, EDMONDS, WA CONSISTS
OF A NEW TWO STORY REPLACEMENT STRUCTURE OF APPROXIMATELY
48,086 GROSS SQUARE FEET OF AUTOMOTIVE SALES, SERVICE AND PARTS
SUPPORT. THE PROJECT ALSO INCLUDES ALL INFRASTRUCTURE AND SITE
WORK NECESSARY TO SUPPORT THE STRUCTURE.
PLUMBING SCOPE
INSTALLATION OF NEW DOMESTIC WATER, WASTE AND
VENT PLUMBING SYSTEM IN SUPPORT OF THE
STRUCTURE. ADDITIONAL SCOPE TO INCLUDE ROOF
DRAINS, RAIN WATER LEADERS, PARKING DECK DRAINAGE,
AND OILY WATER PIPING.
GENERAL NOTES
1. COORDINATE ALL NEW WORK WITH STRUCTURE AND OTHER TRADES.
2. FIELD VERIFY UNIT LOCATIONS, DROPS AND POSITIONS.
3. ALL LINE VOLTAGE WORK SHALL BE BY ELECTRICIAN.
BUILDING INFORMATION
PROJECT ADDRESS:
MAGIC TOYOTA
21300 HIGHWAY 99
EDMONDS, WA 98020
PROPERTY OWNER:
BROADUS FAMILY LLC
120 - 116TH AVE NE
BELLEVUE, WA 98004
TEL 425-775-4422
CONTACT: DAVID BROADUS
SNO CO TAX PARCEL:
00580700000601
00580700000602
00580700000604
00580700000605
00580700000607
00580700000608
CITY OF EDMONDS, LOT
LINE ADJUSTMENT PLN20170016 AND
AS FILED WITH
SNOHOMISH COUNTY AS
DOCUMENT 201705165010 CREATING
LOT 1 AND
LOT 2 WAS FILED AND
RECORDED ON 16 MAY 2017. AS OF
THIS
RE -SUBMITTAL OF PERMIT ISSUE DRAWINGS THE COUNTY HAS
NOT ISSUED
NEW PARCEL NUMBERS
FOR THE AFFECTED PARCELS LISTED ABOVE.
ZONING:
GC-2
CONSTRUCTION TYPE:
B/S-1
FIN FLR ELEV:
+100'-0" (FIRST FLR) & +112'-10"
(SECOND FLR)
PARAPET ELEV:
+128'-0"
CLIMATE ZONE:
4C SNOHOMISH (WSEC TABLE C301.1)
4. A 120-VOLT SERVICE RECEPTACLE SHALL BE LOCATED WITHIN 25' OF EACH PIECE OF EQUIPMENT.
DISCONNECT SHALL BE BY ELECTRICAL CONTRACTOR.
5. PIPE AND DUCT DIMENSIONS SHOWN ARE NOMINAL SIZES.
6. COORDINATE ALL PIPING AND VENTING WITH BELOW GRADE FOUNDATIONS, STRUCTURE, FIRE PROTECTION
AND OTHER TRADES.
7. SANITARY WASTE PIPING SHALL BE INSTALLED AT 1 /4" PER FOOT SLOPE AWAY FROM FIXTURES UNLESS
SHOWN AS OTHERWISE.
8. MAINTAIN 10'-0" MINIMUM DISTANCE BETWEEN OSA INTAKES AND PLUMBING VENTS, EXHAUST AND
COMBUSTION AIR OUTLETS.
COMPLETION AND COMMISSIONING FOR DOMESTIC HOT WATER SYSTEMS
COPIES OF ALL APPLICABLE SERVICE AND EQUIPMENT DATA, AND PROJECT DOCUMENTATION THAT RELATES, SHALL BE PROVIDED TO THE
OWNER AND MADE AVAILABLE TO THE AUTHORITIES HAVING JURISDICTION (AHJ) WITHIN 90 DAYS OF RECEIPT OF THE CERTIFICATE OF
OCCUPANCY INCLUDING:
1. COMMISSIONING PLAN, PRELIMINARY COMMISSIONING REPORT, COMMISSIONING COMPLIANCE CHECKLIST (2015 WSEC FIGURE
C408.1.4.2) AND OTHER RELATED REPORTS SUCH AS BALANCING, START-UP AND/OR PRESSURE TESTING DATA AS APPLICABLE.
2. RECORD DRAWINGS DEPICTING FINAL INSTALLATION CONFIGURATIONS OF SYSTEMS AND EQUIPMENT AS REQUIRED BY 2015 WSEC
SECTION C 103.6.
3. OPERATION AND MAINTENANCE EQUIPMENT MANUALS INCLUDING: MANUFACTURER'S INFORMATION WITH SPECIFIC MODEL NUMBERS
AND OPTIONS NOTED, CONTROLS DATA INCLUDING CALIBRATION AND DESIGN SETPOINT INFORMATION, AND RECOMMENDED
MAINTENANCE SCHEDULE WITH COMFORT SYSTEMS USA NORTHWEST CONTACT INFORMATION.
4. TRAINING OF THE MAINTENANCE STAFF SHALL BE PROVIDED, INCLUDING REVIEW OF DOCUMENTATION, HANDS-ON DEMONSTRATION
OF OPERATION AND START-UP PROCEDURES AS WELL AS A TRAINING COMPLETION REPORT.
WHOLE BUILDING AND COMMISSIONING OF SYSTEMS THAT ARE NOT INCLUDED IN THE PLUMBING SCOPE SHALL BE PROVIDED IN
ACCORDANCE WITH 2O15 WSEC SECTION C408.1 BY OTHERS. COMMISSIONING OF PLUMBING SYSTEMS AND CONTROLS SHALL BE
PROVIDED BY A CERTIFIED COMMISSIONING PROFESSIONAL AS REQUIRED FOR BUILDINGS WITH TOTAL COOLING CAPACITY OVER 240 MBH
AND/OR TOTAL HEATING CAPACITY OVER 300 MBH IN ACCORDANCE WITH 2O15 WSEC SECTION C408.1.
1. DOMESTIC HOT WATER SYSTEMS SHALL BE DESIGNED TO COMPLY WITH MAXIMUM PIPE LENGTHS OR VOLUMES AS REQUIRED BY
2015 WSEC SECTION C404.3.
2. NON -CIRCULATING HOT WATER SYSTEMS SHALL BE PROVIDED WITH HEAT TRAPS IN ACCORDANCE WITH 2O15 WSEC SECTION
C404.4.
3. DOMESTIC HOT WATER PIPING SHALL BE INSULATED PER 2015 WSEC SECTION C404.6 AS FOLLOWS:
FLUID OPERATING MINIMUM INSULATION
TEMPERATURE (7) PIPE SIZE (INCHES) THICKNESS (INCHES)
201-250 <4 2-1/2
201-250 4 AND LARGER 3
141-200 < 1-1 /2 1-1/2
141-200 1-1/2 AND LARGER 2
105-140 <1-1/2 1
105-140 1-1/2 AND LARGER 1-1/2
40-60 <1-1/2 1/2
40-60 1-1/2 AND LARGER 1
HEAT TRACED HOT WATER SYSTEM: PER MANUFACTURER OR PER ABOVE.
4. CIRCULATED AND HEAT TRACED HOT WATER SYSTEMS SHALL BE PROVIDED WITH ACCESSIBLE, AUTOMATIC SETBACK AND/OR
SHUT-OFF DEMAND BASED CONTROLS AS REQUIRED BY 2015 WSEC SECTION C404.7 AND C404.8.
5. DEMAND RECIRCULATION CONTROLS SHALL BE PROVIDED FOR HOT WATER RECIRCULATION PUMPS AND SHALL LIMIT THE HOT
WATER RETURN TEMPERATURE TO NO MORE THAN 10,VF AS REQUIRED BY 2015 WSEC SECTION C404.8(2).
6. CLEANOUTS SHALL BE LOCATED IN HORIZONTAL WASTE PIPING AS REQUIRED BY 2015 UPC SECTION 707.4, INCLUDING ONE AT
EACH UPPER TERMINAL, EACH CHANGE OF DIRECTION THAT IS GREATER THAN 135° AND IN RUNS GREATER THAN 100 FEET IN
LENGTH.
7. FIXTURES LOCATED ON A FLOOR LEVEL THAT IS BELOW THE NEXT UPSTREAM MANHOLE OR BELOW THE MAIN SEWER LEVEL
SHALL BE PROVIDED WITH BACKWATER VALVES AS REQUIRED BY 2015 UPC SECTION 710.1.
8. ALL FIXTURES AND APPLIANCES SERVED BY DOMESTIC HOT WATER SHALL BE PROVIDED WITH A CIRCULATING HOT WATER
SYSTEM (CIRCULATING HOT WATER SYSTEMS ARE CONSIDERED A SOURCE OF HEATED WATER). THE DOMESTIC HOT WATER
CIRCULATED PIPING SYSTEMS THROUGHOUT THIS PROJECT SHALL BE LOCATED WITHIN THE ALLOWABLE DISTANCES FROM PUBLIC
LAVATORY FIXTURES AND OTHER APPLIANCE POINTS OF USE AS PRESCRIBED IN 2015 WSEC TABLE C404.3.1.
9. PROVIDE SEISMIC BRACING AND SUPPORTS IN ACCORDANCE WITH 2O15 IBC FOR SEISMIC DESIGN CATEGORY D AND BASED ON
A SEISMIC IMPORTANCE FACTOR OF 1.0 FOR ALL SYSTEMS, EXCEPTING THE GAS PIPING SHALL HAVE AN IMPORTANCE FACTOR
OF 1.5.
10. NEW BUILDINGS AND ADDITIONS WITH A GROSS CONDITIONED FLOOR AREA OVER 50,000 SQUARE FEET SHALL BE PROVIDED
WITH ENERGY METERING AND ENERGY CONSUMPTION MANAGEMENT AS REQUIRED BY 2015 WSEC SECTION C409.
VICINITY MAP
I I \VV Ll� I JI I L
APN 000140-0036
NORTH
GENERAL - LEGEND
FTU --0 EQUIPMENT TAG TYPE
212 -■EQUIPMENT TAG NUMBER
1 -■DETAIL OR DIAGRAM NUMBER
M1 -■SHEET NUMBER WHERE DETAIL/DIAGRAM SHOWN
-�----SECTION LETTER
M1 --�-SHEET NUMBER WHERE SECTION IS SHOWN
1 REVISION CLOUD AND CHRONOLOGICAL NUMBER
DETAIL REFERENCE OUTLINE
POINT OF CONNECTION TO EXISTING OR TO
OTHERS' WORK
10 KEY NOTE CALLOUTS
WCx PLUMBING FIXTURE CALLOUTS
WORK TO BE REMOVED
0 INDICATES DIAMETER OR ROUND
DRAWING INDEX
SHEET #
SHEET TITLE
SCALE
P001
PLUMBING
COVER SHEET
N/A
P002
PLUMBING
EQUIPMENT SCHEDULES
N/A
P003
PLUMBING
EQUIPMENT SCHEDULES
N/A
P100
PLUMBING
SITE PLAN
1/32"=1'-0"
P101
PLUMBING
FOUNDATION PLAN -
NORTH
1/8"=1'-0"
P102
PLUMBING
FOUNDATION PLAN -
SOUTH
1/8"=1$-0"
P103
PLUMBING
FIRST FLOOR PLAN -
NORTH
1/8"=1'-0"
P104
PLUMBING
FIRST FLOOR PLAN -
SOUTH
1/8"=1'-0"
P105
PLUMBING
SECOND FLOOR PLAN
- NORTH
1/8"=1'-0"
P106
PLUMBING
SECOND FLOOR PLAN
- SOUTH
1/8"=1'-0"
P107
PLUMBING
ROOF PLAN - NORTH
1/8"=1'-0"
P108
PLUMBING
ROOF PLAN - SOUTH
1/8"=1'-0"
P109
ENLARGED
PLUMBING PLANS
1/4"=1'-0"
P200
STORM WATER RISER DIAGRAM
N/A
N/A
P301
PLUMBING
DETAILS
N/A
P302
PLUMBING
DETAILS
N/A
COPYRIGHT NOTICE
THIS LAYOUT/DESIGN IS A
COPYRIGHTED WORK OWNED BY
COMFORT SYSTEMS USA
(NORTHWEST), INC. ("COMFORT
SYSTEMS NORTHWEST") AND
COMFORT SYSTEMS NORTHWEST
HEREBY RESERVES ITS RIGHT TO
PREVENT UNAUTHORIZED
COPYING, PUBLICATION OR USE
OF THIS LAYOUT/DESIGN AND TO
OBTAIN DAMAGES THEREFORE.
z.:
0
0
0
w
U)
W
m
co C
N =
O
Q z
�
Y
N
O Q
CO
00
o)LL
W¢,
W
w�
U 4
Z >_
p
W
IL
ooQO
zm
LL
�2i
Im
o
U
&
CO
SIGNED: 8/11 /2017
F 4 %, TV bind ➢d 8 n -. 4
DESIGNED
CSUSA NW / EE
CHECKED
CSUSA NW / SAL
08/11 /2017
JOB NUMBER
117036
SHEET TITLE
PLUMBING
COVER SHEET
SHEET NUMBER
PLUMBING FIXTURE AND EQUIPMENT SCHEDULE
TAG
EQUIPMENT
LOCATION
CONNECTION SIZES (INCHES)
PUBLIC SYSTEM LOADS
ACCESSORIES / REMARKS
CW
HW
WASTE
VENT
CWSFU
HWSFU
DFU
NOTES
WC-1
TOILET, KOHLER KINGSTON K-4325
RESTROOMS
1"
-
4"
2"
FV
6.0
WALL MOUNT, ELONGATED BOWL, KOHLER K-10959 SENSOR
1, 2
(WHITE) KOHLER FLUSH VALVE, ADA
FLUSH VALVE (BATTERY OPERATED), 1.28 GPF
WC-2
TOILET, KOHLER HIGHLINE K-4325
ROOM 202, 203
1 "
-
4"
2"
FV
6.0
WALL MOUNT, ELONGATED BOWL, KOHLER K-10959 SENSOR
1, 2, 3
(WHITE) KOHLER FLUSH VALVE, ADA
FLUSH VALVE (BATTERY OPERATED), 1.28 GPF
UR-1
URINAL, KOHLER BARDON K-4991
RESTROOMS
3/4"
-
2"
2"
FV
2
WALL HUNG, WASHOUT WATER SENSE, KOHLER K-10949
1
(WHITE), ADA
SENSOR FLUSH VALVE (BATTERY OPERATED), 0.125 GPF
L-1
BATHROOM SINK, KOHLER LADENA
RESTROOMS
1/2"
1/2"
2"
2"
0.75
0.75
2.0
23"x16" UNDER COUNTER MOUNT, DYSON AB-09 SHORT
1
K-2215, (WHITE), ADA
FAUCET, HANDS FREE DRYER (120V)
L-2
LAV SINK, KOHLER BRENHAM K-1999
RESTROOMS
1/2"
1/2"
2"
2"
0.75
0.75
2.0
WALL MOUNT, 20"x18" OVAL BOWL, CHICAGO SENSOR FAUCET
1
(WHITE), ADA
EQ-D12A-13ABCP (BATTERY OPERATED), 0.5 GPM
S-1
KITCHEN SINK, ELKAY LRAD331955
ROOM 104, 171
1/2"
1/2"
2"
2"
1.50
1.5
2.0
33"x19.5"x5.5" COUNTER MOUND, DELTA SINGLE HANDLE
1
(STAINLESS STEEL), ADA
FAUCET WITH SPRAYER, 10OLF-HDF
S-2
BAR SINK, ELKAY LRAD221955
ROOM 222
1/2"
1/2"
2"
2"
1.50
1.5
2.0
22"x19.5'65' COUNTER MOUND, DELTA SINGLE HANDLE
1
(STAINLESS STEEL), ADA
FAUCET WITH SPRAYER, 10OLF-HDF
MS-1
MOP SINK, PROFLO PFMB2424
JANITOR 207
1/2"
1/2"
3"
2"
2.25
2.25
2.0
24"x24"x10" FLOOR MOUND, FIAT FAUCET 830AA, WALL
1, 4
(COMPOSITE)
BRACE ROD
DF-1
DRINKING FOUNTAIN, ELKAY BOTTLE
CORRIDORS
1/2"
-
2"
2"
0.50
-
2.0
EZH2O BOTTLE FILLING STATION W/ BI-LEVEL ADA COOLER
1
FILLER, BI-LEVEL, LZSTL8WSLP, ADA
FILTERED, STAINLESS, BTL FILL RIGHT SIDE
DF-2
DRINKING FOUNTAIN, ELKAY BOTTLE
SERVICE 161
1 /2"
-
2"
2"
0.50
-
EZH2O BOTTLE FILLING STATION W/ SINGLE LEVEL, ADA
1
FILLER, ONE LEVEL, EZSDWSLK, ADA
FILTERED, STAINLESS, NO COOLING
MV-1
THERMOSTATIC VALVE, HONEYWELL
HAND SINK
1/2"
1/2"
-
-
-
-
-
POU THERMOSTATIC MIX VALVE SERVING KITCHEN HAND SINKS
1
MODEL #AM10OLF
LOCATIONS
ADJUSTABLE, LIMIT HOT WATER TEMPERATURE AT FAUCETS
MV-2
THERMOSTATIC MIX VALVE
TOILET ROOM
3/4"
3/4"
-
-
-
-
-
MASTER THERMOSTATIC MIX VALVE SERVING PUBLIC LAYS
1
MODEL #AM102R-US-1
LAV LOCATIONS
ADJUSTABLE, LIMIT HOT WATER TEMPERATURE AT LAYS
HB-1
HOSE BIBB, WOODFORD MODEL 22
INTERIOR
3/4"
3/4"
-
-
1.87
1.87
WALL HYDRANT, CW/HW, HOSE CON BACKFLOW PROTECTION
1
HB-2
HOSE BIBB, WOODFORD MODEL 65
INTERIOR
3/4"
_
_
-
2.50
-
WALL HYDRANT, CW ONLY, HOSE CON BACKFLOW PROTECTION
1
TS-1
TRAP SEAL, JR SMITH MODEL 2692
SERVES FD'S
_
_
VARIES
_
_
_
_
FLOOR DRAIN TRAP SEAL, QUAD CLOSE
1
CWO-1
BOXED CW OUTLET, LSP #013817
REFER ICE/COFF
1/2"
_
_
_
_
_
_
PLASTIC ICE MAKER WALL BOX WITH HAMMER ARRESTER
1
FCO-1
FLOOR CLEANOUT, ZURN
WASTE PIPING
_
_
4"
_
_
_
_
ADJUSTABLE FLOOR CLEANOUT, LIGHT DUTY APPLICATIONS
1
MODEL NCO-2450-PV4 (4")
PVC BODY, WITH ADJUSTABLE NICKEL COVER, THREADED PLUG
WCO-1
FLOOR CLEANOUT, ZURN
WASTE PIPING
_
_
4"
_
_
_
_
CLEANOUT TEE, NO HUB CAST IRON, SMOOTH STAINLESS
1
Z1446 WITH ROUND ACCESS COVER
STEEL COVER
FD-1
FLOOR DRAIN, JR SMITH S2005
NUMEROUS
_
_
2"
2"
_
_
4.0
6" ROUND NICKEL BRONZE STRAINER TOP, CAST IRON BODY,
1
6" ROUND STRAINER
LOW PROFILE FINISHED AREA FLOOR DRAIN, NO HUB
FS-1
TRENCH DRAIN, ZURN FD2375, CAST
CAFE
_
_
3"
2"
_
_
6.0
12" x 12"' x 6" DEEP, CAST IRON, PORCELAIN ENAMEL
1
IRON, DOME STRAINER
INTERIOR COATED, ANTI SPLASH STRAINER, NO HUB
NOTES:
1. REFER TO ARCHITECTURAL FOR FINAL FIXTURE AND EQUIPMENT LOCATIONS AND ELEVATIONS FOR MOUNTING HEIGHTS.
2. WATER CLOSETS: PROVIDE COMPLETE WITH SEAT (WHITE), TRIM, ANGLE STOP VALVE, SUPPLY AND REQUIRED ACCESSORIES.
3. TO BE MOUNTED AT ADA HEIGHT.
4. SERVICE SINK (MOP SINK): PROVIDE COMPLETE WITH MOP SERVICE BASIN FAUCET, WALL GUARDS, HOSE & HOSE BRACKET.
5. TRAP SEAL NOT REQUIRED AT OUTLET.
6. FOR EMERGENCY USE ONLY.
SCHEDULE CONTINUES ON P003
PIPING SYSTEMS AND MATERIALS SCHEDULE
SYSTEM
MATERIAL
NOTES
DRAIN, WASTE & VENT PIPING ABOVE GRADE
CAST IRON, NO HUB
1
WASTE & VENT PIPING BELOW GRADE
PVC SCH 40 DWV
2
OILY WATER ABOVE GRADE
CAST IRON, NO HUB
1
OILY WATER BELOW GRADE
PVC SCH 40 DWV
2
DOMESTIC WATER PIPING (CW/HW/HWR)
COPPER TUBING, TYPE L, SOLDERED
1
HYDRONIC WATER MAKEUP
COPPER TUBING, TYPE L, SOLDERED
NATURAL GAS
SCHEDULE 40 BLACK STEEL PIPE, THREADED
CONDENSATE PIPING
TYPE M COPPER
1
INSULATION - WATER SYSTEMS
FIBERGLASS, THICKNESS PER WSEC
3
STORM ABOVE GRADE
CAST IRON, NO HUB
1
STORM BELOW GRADE
PVC SCH 40 DWV
2
REFRIGERANT PIPING ABOVE GRADE
COPPER ACR, BRAZED AND/OR PRE INSULATED COPPER LINE SETS
NOTES:
1. MATERIAL REQUIRED FOR RETURN AIR PLENUM.
2. SOLVENT JOINT WITH SCHEDULE 40 FITTINGS.
3. PIPE INSULATION TO BE HAVE WHITE ALL SERVICE JACKET.
TAG
MANUFACTURER AND MODEL
TYPE
PERFORMANCE
60 HZ ELECTRICAL
WEIGHT
NOTES
GPM
FT H2O
VOLTS
PH
WATTS
LBS
HWP-1
GRUNDFOS CIRCULATOR PUMP UP-15-29 (1/2" LINE CONN.)
INLINE CENTR
1.4
5.3
115
1
85
6.0
1, 2, 3, 4
HWP-2
GRUNDFOS CIRCULATOR PUMP UP-15-29 (1/2" LINE CONN.)
INLINE CENTR
2.1
8.4
115
1
85
6.0
1, 2, 3, 4
NOTES:
1. PROVIDE PUMP WITH CHECK VALVE, POWER LINE CORD, ADJUSTABLE TIMER AND HIGH TEMPERATURE RANGE THERMOSTATIC ON/OFF SWITCH.
2. PUMP SYSTEM SHALL BE ON STAND-BY ENABLED 24 HRS/7 DAYS PER WEEK PUMP ON/RUN TIMER/PUMP OFF (ADJ).
3. NORMAL OCCUPANCY IS SUN - SAT, 7 AM - 11 PM.
4. GPM AND FT H2O ARE CALCULATED VALVES, PUMP SELECTED TO MEET THE DESIGN CRITERIA.
BACKFLOW PREVENTER SCHEDULE i
� mal, I I I
TAG
MANUFACTURER
MODEL
LINE SIZE
(IN)
SERVICE
GPM
TYPE
AIR GAP
(IN)
WATER PRESSURE (PSI)
WEIGHT
(LBS)
NOTES
RP
DC
AG
INLET
OUTLET
RP-1
WATTS
LF009M3QT
1 "
MAKEUP WATER
10
X
2.00
80
67
6
1, 5
NOTES:
1. 0.75" RP DEVICE FOR 1" SERVICE BY DESIGN.
2. PROVIDE WITH MFG'S FUNNEL AIR GAP FITTING. ROUTE DISCHARGE TO NEAREST
FLOOR DRAIN OR OTHER APPROVED LOCATION, AS NOTED.
3. SERVES MAKEUP WATER FOR HYDRONIC BOILERS.
COPYRIGHT NOTICE
THIS LAYOUT/DESIGN IS A
COPYRIGHTED WORK OWNED BY
COMFORT SYSTEMS USA
(NORTHWEST), INC. ("COMFORT
SYSTEMS NORTHWEST") AND
COMFORT SYSTEMS NORTHWEST
HEREBY RESERVES ITS RIGHT TO
PREVENT UNAUTHORIZED
COPYING, PUBLICATION OR USE
OF THIS LAYOUT/DESIGN AND TO
OBTAIN DAMAGES THEREFORE.
Q
1-C-0
C)
E
m
Q
O
r
�
C
O
z
O
cc)
Q
NLLJ
Li
O
o
U
W
U)
w
m
U) co
N =
'-
d
3:
(n o
0
i N
0' N
O Q
°�_00
LL U)
��
Ho
Way,
w
w�
�_�
Wco
p
ry
��
3
zm
Q o
�0
�(
CD
O�
4W
n
c
A
SIGNED: 8/11 /2017
REVISIONS
0. ISSUE FOR PERMIT 8/11/2017
DESIGNED
CSUSA NW / EE
CHECKED
CSUSA NW / SAL
DATE
08/11 /2017
tOB A11:1BER
117031
SHEET TITLE
PLUMBING
EQUIPMENT
SCHEDULES
SHEET NUMBER
l[oll[Ilgra
/ 1
TAG
EQUIPMENT
LOCATION
CONNECTION SIZES (INCHES)
PUBLIC SYSTEM LOADS
ACCESSORIES / REMARKS
NOTES
CW
HW
WASTE
VENT
CWSFU
HWSFU
DFU
TD-1
TRENCH DRAIN, JR SMITH 9930-GHD,
SERVICE
_
_
4"
2"
_
_
8.0
5.25" x 14' x 4" DEEP HEAVY DUTY POLYPRO TRENCH DRAIN
1, 5
HEAVY DUTY WITH GALV STEEL GRATE
WITH 3.25" x 0.375" SLOTTED GRATE, NO HUB OUTLET
TD-2
TRENCH DRAIN, JR SMITH 9930-GHD,
SERVICE
_
_
4"
2"
_
_
8.0
5.25" x 25.75' x 4" DEEP HEAVY DUTY POLYPRO TRENCH
1, 5
HEAVY DUTY WITH GALV STEEL GRATE
DRAIN WITH 3.25" x 0.375" SLOTTED GRATE, NO HUB OUTLET
TD-3
TRENCH DRAIN, JR SMITH 9930-GHD,
WASH/DETAIL
_
_
4"
2"
_
_
8.0
5.25" x 32.25' x 4" DEEP HEAVY DUTY POLYPRO TRENCH
1, 5
HEAVY DUTY WITH GALV STEEL GRATE
DRAIN WITH 3.25" x 0.375" SLOTTED GRATE, NO HUB OUTLET
TD-4
TRENCH DRAIN, JR SMITH 9930-GHD,
WASH/DETAIL
_
_
4"
2"
_
_
8.0
5.25" x 52' x 4" DEEP HEAVY DUTY POLYPRO TRENCH
1, 5
HEAVY DUTY WITH GALV STEEL GRATE
DRAIN WITH 3.25" x 0.375" SLOTTED GRATE, NO HUB OUTLET
TD-5
TRENCH DRAIN, JR SMITH 9930-GHD,
NEW CAR DEL
_
_
4"
2"
_
_
8.0
5.25" x 39' x 4" DEEP HEAVY DUTY POLYPRO TRENCH
1, 5
HEAVY DUTY WITH GALV STEEL GRATE
DRAIN WITH 3.25" x 0.375" SLOTTED GRATE, NO HUB OUTLET
RD-1
ROOF DRAIN, JR SMITH
ROOF AND
-
-
STORM
-
-
-
-
SIZE SHOWN ON DRAWINGS, CAST IRON BODY, GRAVEL STOP
1
MODEL 1010Y - NH CAST IRON
PARKING DECK
VARIES
AND FLASHING CLAMP, CAST IRON DOME
ORD-1
OVERFLOW ROOF DRAIN, JR SMITH
ROOF AND
-
-
STORM
-
-
-
-
SIZE SHOWN ON DRAWINGS, CAST IRON BODY, GRAVEL STOP
1
MODEL 1080Y - NH CAST IRON
PARKING DECK
VARIES
AND FLASHING CLAMP, CAST IRON WATER DAM AND DOME
EEW-1
EMERGENCY EYEWASH, HAWES SE490
SERVICE
_
_
_
1/27'
1/27'
-
-
MULTIPLE LOCATIONS, DRAIN DIRECT TO FLOOR
1, 6
WITH H9201 EW MIXING VALVE
NOTES:
1. REFER TO ARCHITECTURAL FOR FINAL FIXTURE AND EQUIPMENT LOCATIONS AND ELEVATIONS FOR MOUNTING HEIGHTS.
2. WATER CLOSETS: PROVIDE COMPLETE WITH SEAT (WHITE), TRIM, ANGLE STOP VALVE, SUPPLY AND REQUIRED ACCESSORIES.
3. TO BE MOUNTED AT ADA HEIGHT.
4. SERVICE SINK (MOP SINK): PROVIDE COMPLETE WITH MOP SERVICE BASIN FAUCET, WALL GUARDS, HOSE & HOSE BRACKET.
5. TRAP SEAL NOT REQUIRED AT OUTLET.
6. FOR EMERGENCY USE ONLY.
TAG
MANUFACTURER AND MODEL
ASSOCIATED EQUIPMENT
DESCRIPTION
INLET PRESSURE
(PSIG)
OUTLET PRESSURE
(IN W.C.)
PRV MAX CAP
(CFH)
INDIVIDUAL LOAD
(CFH)
CONN SIZE
(IN)
NOTES
PRV-1
MAXITROL 325-31-
RTU-1
NAT GAS
2
10
250
180
0.5
1, 2, 3
PRV-2
MAXITROL 325-31-
RTU-2
NAT GAS
2
10
250
125
0.5
1, 2, 3
PRV-3
MAXITROL 325-31-
RTU-3
NAT GAS
2
10
250
125
0.5
1, 2, 3
PRV-4
MAXITROL 325-31-
RTU-4
NAT GAS
2
10
250
180
0.5
1, 2, 3
PRV-5
MAXITROL 325-31-
RTU-5
NAT GAS
2
10
250
180
0.5
1, 2, 3
PRV-6
MAXITROL 325-91-
CO GEN UNIT (BY OTHERS)
NAT GAS
2
10
2,250
1,455
1.5
1, 2, 3
PRV-7
MAXITROL 325-7AL
B-1
NAT GAS
2
10
1,250
594
1.25
1, 2, 3
PRV-8
MAXITROL 325-7AL
B-2
NAT GAS
2
10
1,250
594
1.25
1, 2, 3
NOTES:
1. VENT VALVES TO ATMOSPHERE PER MANUFACTURER'S INSTALLATION INSTRUCTIONS.
2. VALVES SHALL BE SUITABLE FOR OUTDOOR INSTALLATION.
3. ALL CONNECTION SIZES SHOWN ARE NOMINAL. EXACT SIZES AND CONFIGURATION SHALL BE CONFIRMED WITH THE APPROVED PRODUCT SUBMITTAL
DATASHEETS AND MANUFACTURER'S INSTALLATION INSTRUCTIONS.
I I I I to] I kal81m1_\II ska.17_\II skiYN.1a110I I
TAG
MANUFACTURER AND MODEL
LOCATION
CAPACITY & RECOVERY
60 HZ ELEC
DRY WT
OPERATIONAL WT
NOTES:
GAL
GPH@90°F RISE
V
A
PH
INPUT (KW)
(LBS)
(LBS)
EWH-1
AO SMITH DRE-52-9
ROOM 207
50
41
480
10.8
3
9.0
265
682
1, 3, 4, 5
EWH-2
AO SMITH DRE-120-24
ROOM 114
120
109
480
28.9
3
24.0
390
1,383
1, 2, 4, 6
NOTES:
1. WATER HEATER BASIS OF DESIGN, EQUIPMENT MAY BE SUBSTITUTED
2. DOMESTIC HOT WATER SERVICE FOR OFFICE SIDE OF BUILDING.
3. DOMESTIC HOT WATER SERVICE FOR SHOP SIDE OF BUILDING.
4. PROVIDE WITH RELIEF VALVE FACTORY SET TO 125 PSI.
FOR EQUAL OR OTHER APPROVED MANUFACTURER, REFERENCE APPROVED SUBMITTALS.
5. PROVIDE SYSTEM WITH AMTROL THERMAL EXPANSION TANK ST-5, TAG ET-1.
6. PROVIDE SYSTEM WITH AMTROL THERMAL EXPANSION TANK ST-12, TAG ET-2.
COPYRIGHT NOTICE
THIS LAYOUT/DESIGN IS A
COPYRIGHTED WORK OWNED BY
COMFORT SYSTEMS USA
(NORTHWEST), INC. ("COMFORT
SYSTEMS NORTHWEST") AND
COMFORT SYSTEMS NORTHWEST
HEREBY RESERVES ITS RIGHT TO
PREVENT UNAUTHORIZED
COPYING, PUBLICATION OR USE
OF THIS LAYOUT/DESIGN AND TO
OBTAIN DAMAGES THEREFORE.
•
•
•
O
o
�
W
�
N
w
m
fn CD
N =
~
d0
d
O
z
�
Y
N
O Q
N
M
� =)
= �
Cn
U
W Q
W �j
W
W W
p
:
w
Z >-
C �-
0
�
IL F
3
om
Qo
LL
�2i
c\jo
o
00
SIGNED: 8/11 /2017
September7, 2017
DESIGNED
CSUSA NW / EE
CHECKED
CSUSA NW / SAL
DATE
08/11/2017
tOB AlRIBER
SHEET TITLE
PLUMBING
EQUIPMENT
SCHEDULES
SHEET NUMBER
COPYRIGHT NOTICE
THIS LAYOUT/DESIGN IS A
COPYRIGHTED WORK OWNED BY
COMFORT SYSTEMS USA
(NORTHWEST), INC. ("COMFORT
SYSTEMS NORTHWEST") AND
COMFORT SYSTEMS NORTHWEST
HEREBY RESERVES ITS RIGHT TO
PREVENT UNAUTHORIZED
COPYING, PUBLICATION OR USE
GENERAL NOTES . OF THIS LAYOUT/DESIGN AND TO
1 DRAWINGS FOR PLUMBING WORK WITHIN THE OBTAIN DAMAGES THEREFORE.
NEW BUILDING SPACE AND ROOFTOP ARE
DIAGRAMMATIC AND INTENDED TO CONVEY
SCOPE AND GENERAL ARRANGEMENT ONLY.
THE ACCURACY AND COMPLETENESS OF THE
DESIGN CONTENT REQUIRES FIELD
VERIFICATION FOR ALL LOCATIONS AND C-0
DIMENSIONS PRIOR TO START OF PLUMBING
WORK. CD
00
2. PLUMBING WORK LIMITED TO 5-0" FROM
if
BUILDING EXTERIOR WALLS, REFER TO CIVIL
PLANS FOR CONTINUATION. ui
r
3. STORM WATER CONVEYED BY GUTTERS AND C:) 0
EXTERNAL DOWNSPOUTS ARE NOT PART OF co
THE PLUMBING SCOPE.
Lu
4. FOOTING DRAINS AND DEWATERING TO BE
PROVIDED BY OTHERS.
5. INVERT ELEVATIONS IN THE KEY NOTES ARE
ROPERTY LINE
FOR REFERENCE ONLY IN REFERENCE TO THE CIVIL POINTS OF
CONNECTION, REFERENCE CIVIL DRAWINGS.
6. OIL/WATER SEPARATOR PROVIDED AND
INSTALL BY CIVIL SHALL BE PROPERLY
VENTED, REFERENCE CIVIL DRAWINGS.
Lu
W
uj
co 3:
7. FLOOR DRAINS AND TRENCH DRAINS
C\l
>:
co
99
CONNECTED TO THE OIL/WATER SEPARATOR co ry
< 0
<
ARE NOT TRAPPED BECAUSE THE OIL/WATER 0 CN 0
0 w
SEPARATOR IS THE TRAP PROVIDING A WATER " u-
SEAL. AS SUCH, THESE FLOOR DRAINS AND -T- C") 0 U)
U) IC) cc) c)
TRENCH DRAINS ARE NOT VENTED. < UJ Lu W
ry
-1 Lu U)
0 --1
8. DOMESTIC WATER RPBA PROVIDED UNDER r Lu c)
SEE CIVIL PLAN FOR ry
ry 0
0
-3.1 AND CIVIL SCOPE, SEE SHEETS CWCONTINUATION OF LL
0 0
LL
2: co
IPING (TYP) C-3.4. C\j 0
C) C)
0/1
00
'A
bm
0
W� 14"RWL
foRWL A. Lp
�,'17DW '�4
V)
W
"RWL spy
4
41 OW
CN
Fl 7--- FF=377.00'
CN /Z
F THIS AREA IN
898
SCOPE OF WORK
T
CL
W j 3"RW
NAL
T T
----------------------
SIGNED: 8/11/2017
RIDGE LINE
-j
ROPERTY LINE --T
o REVISIONS
FOR REFERENCE
ONLY
0. ISSUE FOR PERMIT 8/11/2017
PLUMBING WORK LIMITED TO
FF=377.00' 5'-0" FROM BUILDING --------
EXTERIOR WALL, REFER TO RAINBOW CONSULTING
4"RWL GAS PIPING TO CIVIL PLANS FOR
R E V I E W E D
BLDG SYSTEMS r---,! ------ :
CONTINUATION (TYPICAL)
4"RWL
4"RWL
September 7, 2017
DESIGNED
PROPOSED PSE METER LOCATION
SEE CIVIL PLAN FOR
WITH 2" PSIG DELIVERY PRESSURE
CSUSA NW EE
CONTINUATION OF f
(METER BY OTHERS)
PIPING (TYP)
CHECKED
CSUSA NW SAL
SEE CIVIL FOR CONTINUATION
OF GAS PIPING
DATE
-------- ---- --- 08/11/2017
JOB NUMBER
117036
ROPERTY LINE SHEET TITLE
FOR REFERENCE ONLY PLUMBING
SITE PLAN
,4'
L7-�
--P
R EAI CN
'0 RE V
Septemb
R Eyl wEt) sy�
L r.�npn-zrn �F UP
SHEET NUMBER
PLUMBING SITE PLAN
SCALE: 1/32" = l'-O" P i 00
2"W UP
"W UP
2'V UP i
4"W UP 2"V UP J
2"W UP
2"V UP
3"W UP 3"W
2"W
4"UPT
GENERAL NOTES:
1. DRAWINGS FOR PLUMBING WORK WITHIN THE
NEW BUILDING SPACE AND ROOFTOP ARE
DIAGRAMMATIC AND INTENDED TO CONVEY
SCOPE AND GENERAL ARRANGEMENT ONLY.
THE ACCURACY AND COMPLETENESS OF THE
DESIGN CONTENT REQUIRES FIELD
VERIFICATION FOR ALL LOCATIONS AND
DIMENSIONS PRIOR TO START OF PLUMBING
WORK.
2. PLUMBING WORK LIMITED TO 5-0" FROM
BUILDING EXTERIOR WALLS, REFER TO CIVIL
PLANS FOR CONTINUATION.
3. STORM WATER CONVEYED BY GUTTERS AND
EXTERNAL DOWNSPOUTS ARE NOT PART OF
THE PLUMBING SCOPE.
4. FOOTING DRAINS AND DEWATERING TO BE
PROVIDED BY OTHERS.
5. INVERT ELEVATIONS IN THE KEY NOTES ARE
IN REFERENCE TO THE CIVIL POINTS OF
CONNECTION, REFERENCE CIVIL DRAWINGS.
6. OIL/WATER SEPARATOR PROVIDED AND
INSTALL BY CIVIL SHALL BE PROPERLY
VENTED, REFERENCE CIVIL DRAWINGS.
7. FLOOR DRAINS AND TRENCH DRAINS
CONNECTED TO THE OIL/WATER SEPARATOR
ARE NOT TRAPPED BECAUSE THE OIL/WATER
SEPARATOR IS THE TRAP PROVIDING A WATER
SEAL AS SUCH, THESE FLOOR DRAINS AND
TRENCH DRAINS ARE NOT VENTED.
8. DOMESTIC WATER RPBA PROVIDED UNDER
CIVIL SCOPE, SEE SHEETS C-3.1 AND
C-3.4.
Plans are approved contingent upon The following:
A
1
N
1
T
A
S
H
H
1
7 1
KEY PLAN
COPYRIGHT NOTICE
THIS LAYOUT/DESIGN IS A
COPYRIGHTED WORK OWNED BY
COMFORT SYSTEMS USA
(NORTHWEST), INC. ("COMFORT
SYSTEMS NORTHWEST") AND
COMFORT SYSTEMS NORTHWEST
HEREBY RESERVES ITS RIGHT TO
PREVENT UNAUTHORIZED
COPYING, PUBLICATION OR USE
OF THIS LAYOUT/DESIGN AND TO
OBTAIN DAMAGES THEREFORE.
0
O
o
�
W%,m,
ui
N
w
m
fn co
N =
O
z
�
Y
N
O Q
N
M0
LL W
110
=
Cn
U
W Q
W cq
W
wW
p
W
0 �-
0
�M
Oz cn
QO
LL
o
o
00
SIGNED: 8/11 /2017
REVISIONS
0. ISSUE FOR PERMIT 8/11/2017
LREVIEWED
SSptember , 201
RIVIEW ED
By,
DESIGNED
CSUSA NW / EE
CHECKED
CSUSA NW / SAL
SHEET TITLE
PLUMBING
FOUNDATION
PLAN - NORTH
adm144AZ 0161A4:1
PLUMBING FOUNDATION PLAN - NORTH
ISCALE: 1 /8" = 1 '-0"
6" STORM
IE=375.17'
6" STORM
IE=374.50'
3" STORM
IE=375.46
f
GENERAL NOTES:
1. DRAWINGS FOR PLUMBING WORK WITHIN THE
NEW BUILDING SPACE AND ROOFTOP ARE
DIAGRAMMATIC AND INTENDED TO CONVEY
SCOPE AND GENERAL ARRANGEMENT ONLY.
THE ACCURACY AND COMPLETENESS OF THE
DESIGN CONTENT REQUIRES FIELD
VERIFICATION FOR ALL LOCATIONS AND
DIMENSIONS PRIOR TO START OF PLUMBING
WORK.
2. PLUMBING WORK LIMITED TO 5-0" FROM
BUILDING EXTERIOR WALLS, REFER TO CIVIL
PLANS FOR CONTINUATION.
3. STORM WATER CONVEYED BY GUTTERS AND
EXTERNAL DOWNSPOUTS ARE NOT PART OF
THE PLUMBING SCOPE.
4. FOOTING DRAINS AND DEWATERING TO BE
PROVIDED BY OTHERS.
5. INVERT ELEVATIONS IN THE KEY NOTES ARE
IN REFERENCE TO THE CIVIL POINTS OF
CONNECTION, REFERENCE CIVIL DRAWINGS.
6. OIL/WATER SEPARATOR PROVIDED AND
INSTALL BY CIVIL SHALL BE PROPERLY
VENTED, REFERENCE CIVIL DRAWINGS.
7. FLOOR DRAINS AND TRENCH DRAINS
CONNECTED TO THE OIL/WATER SEPARATOR
ARE NOT TRAPPED BECAUSE THE OIL/WATER
SEPARATOR IS THE TRAP PROVIDING A WATER
SEAL AS SUCH, THESE FLOOR DRAINS AND
TRENCH DRAINS ARE NOT VENTED.
8. DOMESTIC WATER RPBA PROVIDED UNDER
CIVIL SCOPE, SEE SHEETS C-3.1 AND
C-3.4.
�
O
O
�
O
O
KEY PLAN
COPYRIGHT NOTICE
THIS LAYOUT/DESIGN IS A
COPYRIGHTED WORK OWNED BY
COMFORT SYSTEMS USA
(NORTHWEST), INC. ("COMFORT
SYSTEMS NORTHWEST") AND
COMFORT SYSTEMS NORTHWEST
HEREBY RESERVES ITS RIGHT TO
PREVENT UNAUTHORIZED
COPYING, PUBLICATION OR USE
OF THIS LAYOUT/DESIGN AND TO
OBTAIN DAMAGES THEREFORE.
0
O
o
�
W%,m,
ui
N
W
m
fn co
N =
~
m
co
O
Q z
Y O-
N
O Q
MCn
o N
LL Cn
Ito
=
0 Cn
U
W Q
W L0
W
W H
dN�
Z >-
p WLL
IL
F
3
om
Qo
�2i
c\jo
o
00
SIGNED: 8/11 /2017
REVISIONS
0. ISSUE FOR PERMIT 8/11/2017
LREVIEWED
:m r 7, 2017
REVIEW sy
ED
DESIGNED
CSUSA NW / EE
CHECKED
CSUSA NW / SAL
SHEET TITLE
PLUMBING
FOUNDATION
PLAN - SOUTH
s
l:144AZ 0161A4:1
PLUMBING FOUNDATION PLAN - SOUTH
ISCALE: 1 /8" = 1 '-0"
J-1. 8f
F l .UF E -_ "O -
FD-1
SEE 1/P301
1
P 109
D � -
i
SEE 1/P301
EWH-2
SEE 2/P301
---------- ---
t t
------------
PLUMBING FIRST FLOOR PLAN NORTH
i
10,
�. T/I
-
------- ------
;
J,
3"V, SIDE WALL
TERMINATION
r t WC-2 L-2 I I 2 7
n
f
4" RAIL UP TO
12 I RD & ORD
i u we 2 I uR 1 uR-� UR-� I _ ' (2 SQ FT.)_ --
DF-2
I i 7157I
f1»
3" RWL UP TO I �.��..�.�_--------------
RD & ORD A OW-,,_ 1721,
(2,252 SQ. Ff.)
3" RAIL UP TO
RD & ORD
(160 SQ. FT.)
L
............
,f
r
FCo-1 3")
SEE 2/(P301 1/2-
3/4
j 3/4" 2" (3,433 MBH) I 1/2"
2"V UP EEw-1 I 1Y4" (7901 MBH) Q11,111--11, rkt= �-
GAS GAS r GAS
-- -
-----L----------
-
- ----- --- . } _:==111111 -----------------
GAS GAS GAST GAS '� , — GAS G
�
� , I 1 /2„
_ HB-2
W
1"CW UP SEE 2/P302
/ _ --
� NATURAL GAS M � 1-1 4" UP 3" vr, ; <t ���� � 3 � I 3" DWI DN E
METER BY P.S.E. I(1,188 MBH) ; (471 SQ. FT.)
SEE 9/P301 1Y4" (1,455 MBH) PRv-s
y (1,455 MBH)
3" RAIL UP TO
- RD & ORD
(471 SQ. FT.)
1
A!R-16,
GENERAL NOTES:
1. WITH RESPECT TO DOMESTIC HOT WATER
RECIRC LINES, THE RECIRC SHALL RUN TO A
LENGTH NO GREATER THAT THAT SHOWN IN
WSEC TABLE C404.3.1.
A
1
N
7 1
A
S
H
H
1
7 1
KEY PLAN
COPYRIGHT NOTICE
THIS LAYOUT/DESIGN IS A
COPYRIGHTED WORK OWNED BY
COMFORT SYSTEMS USA
(NORTHWEST), INC. ("COMFORT
SYSTEMS NORTHWEST") AND
COMFORT SYSTEMS NORTHWEST
HEREBY RESERVES ITS RIGHT TO
PREVENT UNAUTHORIZED
COPYING, PUBLICATION OR USE
OF THIS LAYOUT/DESIGN AND TO
OBTAIN DAMAGES THEREFORE.
0
N
00
Q �
U6
= 0
o z
o p
co
N o
L1J
O
o
U
W%,m,
H
u.!
t::
U)
W
m
Cn co
N =
~
C7,
d
00
Q z
�
Y OF-
N
Q
OLL
N
co
rn
ob
LL co
ova
W ¢
Lu
W 1-
U
Z U)
p
W
=W
��
O oLL
zm
Q O
��
J
o
U
�
co
Ste`
SIGNED: 8/11 /2017
REVISIONS
0. ISSUE FOR PERMIT 8/11/2017
DESIGNED
CSUSA NW / EE
CHECKED
CSUSA NW / SAL
08/11 /2017
tOB A41:11BER
11 i •,
SHEET TITLE
PLUMBING FIRST
FLOOR PLAN -
NORTH
GENERAL NOTES:
1. WITH RESPECT TO DOMESTIC HOT WATER
RECIRC LINES, THE RECIRC SHALL RUN TO A
LENGTH NO GREATER THAT THAT SHOWN IN
WSEC TABLE C404.3.1.
o�
�
o
0
�.o
o--
�o
KEY PLAN
COPYRIGHT NOTICE
THIS LAYOUT/DESIGN IS A
COPYRIGHTED WORK OWNED BY
COMFORT SYSTEMS USA
(NORTHWEST), INC. ("COMFORT
SYSTEMS NORTHWEST") AND
COMFORT SYSTEMS NORTHWEST
HEREBY RESERVES ITS RIGHT TO
PREVENT UNAUTHORIZED
COPYING, PUBLICATION OR USE
OF THIS LAYOUT/DESIGN AND TO
OBTAIN DAMAGES THEREFORE.
•
•
0
z.,
N
00
Q �
U6
= 0
o z
o p
co
lir-
N o
L1J
O
o
U
W%,m,
H
ui
t::
U)
W
m
Cn co
N =
~
d00
Q z
:D O
Y OF-
N
O Q
0 N
LL Co
F
LL Co
co
0
0000
W ¢
LU
75;
Lu
W F-
pcnW
�0
��
oo
zm
o
QLL
��
J
o
U
�
&
co
SIGNED: 8/11 /2017
REVISIONS
0. ISSUE FOR PERMIT 8/11/2017
DESIGNED
CSUSA NW / EE
CHECKED
CSUSA NW / SAL
08/11 /2017
tOB ilill:IBER
11 i •,
SHEET TITLE
PLUMBING FIRST
FLOOR PLAN -
SOUTH
Ed 0 1 :4 A Cl 1116 11:4 7
lwj
--------- -- ------ ---- --- -------- ---------- - -
�_sf
---------------------------- - - - ----------------
---------------------------------------------- - - - --- - - ------------------------ - - ----------------------------
_ I l
I I ,
I i
----------------------- - ----
---------- .........................................
----------- --
i
� I
i
I I '
}
'
-------- -- --- ----------- - - - - -
PLUMBING SECOND FLOOR PLAN - NORTH
ISCALE: 1/8" = 1'—O"
GENERAL NOTES:
1. WITH RESPECT TO DOMESTIC HOT WATER
RECIRC LINES, THE RECIRC SHALL RUN TO A
LENGTH NO GREATER THAT THAT SHOWN IN
WSEC TABLE C404.3.1.
A
1
1
T
A
H7
PN///S
1
KEY PLAN
COPYRIGHT NOTICE
THIS LAYOUT/DESIGN IS A
COPYRIGHTED WORK OWNED BY
COMFORT SYSTEMS USA
(NORTHWEST), INC. ("COMFORT
SYSTEMS NORTHWEST") AND
COMFORT SYSTEMS NORTHWEST
HEREBY RESERVES ITS RIGHT TO
PREVENT UNAUTHORIZED
COPYING, PUBLICATION OR USE
OF THIS LAYOUT/DESIGN AND TO
OBTAIN DAMAGES THEREFORE.
•
•
0_ J
0
z.,
N
00
Q �
U6
= 0
O z
O p
co
lir-
N o
L1J
O
O
U
W%,M,
H
UJ
t::
U)
W
m
Cn co00
N =
Q z
:D O
Y OF-
N
O Q
0 N
LL Co
F
LL Co
co
0
0000
W ¢
LU
75;
Lu
W F-
pcnW
� w
��
oo
zm
Qo
LL
��
o
U
&
co
SIGNED: 8 11 2017
REVISIONS
0. ISSUE FOR PERMIT 8/11/2017
L"* " -477
7, 17
lE Y.
DESIGNED
CSUSA NW / EE
CHECKED
CSUSA NW / SAL
�L._j:14=ki,III J,r=141 l
a ,
GENERAL NOTES:
1. WITH RESPECT TO DOMESTIC HOT WATER
RECIRC LINES, THE RECIRC SHALL RUN TO A
LENGTH NO GREATER THAT THAT SHOWN IN
WSEC TABLE C404.3.1.
-i -- -- - - - ----- - ----
L�
-4-------- _ ----- — - -- - - - - -- -
v
3"
4" RWL DN x
(6,379 SQ. FT.K
3" RWL UP TO
RD & ORD
(3,209 SQ. FT.)
rf ,
-3" RWL UP TO
TO RD & ORD
(28 SQ. FT.)
3" RWL DN
(28 SQ. FT.)
o�
�
o
0
�.o
o--
�o
KEY PLAN
COPYRIGHT NOTICE
THIS LAYOUT/DESIGN IS A
COPYRIGHTED WORK OWNED BY
COMFORT SYSTEMS USA
(NORTHWEST), INC. ("COMFORT
SYSTEMS NORTHWEST") AND
COMFORT SYSTEMS NORTHWEST
HEREBY RESERVES ITS RIGHT TO
PREVENT UNAUTHORIZED
COPYING, PUBLICATION OR USE
OF THIS LAYOUT/DESIGN AND TO
OBTAIN DAMAGES THEREFORE.
•
•
0_ J
0
T%
N
00
Q �
U6
= 0
O z
O p
co
lir-
N o
L1J
O
o
U
H
ui
�
U)
w
m
co co
N =
~
co
d00
Q z
:D O
Y OF-
N
O Q
N
LL Co
F
LL Co
co
0
0000
w Q
w
75;
Lu
w 1—
pcnw
� w
��
oo
zm
Qo
LL
��
o
U
&
co
SIGNED: 8/11 /2017
REVISIONS
0. ISSUE FOR PERMIT 8/11/2017
DESIGNED
CSUSA NW / EE
CHECKED
CSUSA NW / SAL
DATE
08/11 /2017
JOB NUMBER
117036
SHEET TITLE
PLUMBING
SECOND FLOOR
PLAN - SOUTH
Ed01:4AClII161140
ISCALE: 1/8" = 1'—O"
A
1
N
7 1
A
S
H
H
1
7 1
KEY PLAN
COPYRIGHT NOTICE
THIS LAYOUT/DESIGN IS A
COPYRIGHTED WORK OWNED BY
COMFORT SYSTEMS USA
(NORTHWEST), INC. ("COMFORT
SYSTEMS NORTHWEST') AND
COMFORT SYSTEMS NORTHWEST
HEREBY RESERVES ITS RIGHT TO
PREVENT UNAUTHORIZED
COPYING, PUBLICATION OR USE
OF THIS LAYOUT/DESIGN AND TO
OBTAIN DAMAGES THEREFORE.
0
O
o
�
W
�
N
W
m
fn co
N =
~
m
co
Q z
=) O
Y
N
O Q
N
M
� =)
= �
0 Cn
U
W Q �
W L0
W
W H
p
W
E-
0
�
F
3
om
Qo
LL
�2i
o
o00
SIGNED: 8/11 /2017
REVISIONS
0. ISSUE FOR PERMIT 8/11/2017
DESIGNED
CSUSA NW / EE
CHECKED
CSUSA NW / SAL
DATE
08/11/2017
JOB NUMBER
117036
SHEET TITLE
PLUMBING ROOF
PLAN - NORTH
s
l:144i Z 11,1161A4:1
- ----------- c
---- ------------------- ---- ------------------- I --- -------------------
E
I PLUMBING ROOF PLAN - SOUTH
O
noul
IF1
fi vi
EFA
an
KEY PLAN
COPYRIGHT NOTICE
THIS LAYOUT/DESIGN IS A
COPYRIGHTED WORK OWNED BY
COMFORT SYSTEMS USA
(NORTHWEST), INC. ("COMFORT
SYSTEMS NORTHWEST") AND
COMFORT SYSTEMS NORTHWEST
HEREBY RESERVES ITS RIGHT TO
PREVENT UNAUTHORIZED
COPYING, PUBLICATION OR USE
OF THIS LAYOUT/DESIGN AND TO
OBTAIN DAMAGES THEREFORE.
0
6w-C
C)
00
<
LD C6
= r)
C) 71
cD C)
co
C,4
LLJI
:5
0
C)
0
ui
t::
U)
Lu
M
cf) 00
CF)
00
::) 0
0
cf) 7;7
F- CN
0 <
Cr) C14
(T
LL W
2 :D
110
C")
COCO)
0 U)
o 7--
U)
ui
LLJ Lo
LLJ
W
of 04
cf)
Lu W
p
4)
Ld�-
Fr- M:
IL
C_ F_
00
2: cn
0
LL
2i
04
0
J(o
C)
0
13�N
00
SIGNED: 8/11/2017
REVISIONS
0. ISSUE FOR PERMIT 8/11/2017
7tee
TG
er 7, 2017
DESIGNED
CSUSA NW / EE
CHECKED
CSUSA NW / SAL
tOB ilill:IBER
11 703C6,
SHEET TITLE
PLUMBING ROOF
PLAN - SOUTH
Ed 0 1:4 A d'Ll I I 16 114 0
7id m$oo
ISCALE: 1/8" = V-0"
GENERAL NOTES:
1. WATER HAMMER ARRESTORS REQUIRED AT FLUSH VALVE LOCATIONS,
SEE DETAIL 7/P301.
2. DOMESTIC WATER HEATER PIPING IN TOILET ROOMS TO REMAIN
FULL SIZE THROUGHOUT THE ENTIRETY OF THE HEADER SYSTEM.
3. DOMESTIC WATER, WASTE AND VENT CONNECTION SIZES TO
FIXTURES ARE TO BE AS SHOWN ON THE FIXTURE SCHEDULE.
4. ALL FLOOR DRAINS TO HAVE TRAP GUARDS.
SCALE: 1/8" = 1'-O"
2
%
WC-2
f/ I DF-1
2„
----------------
2" UR-1
'I I
2°,. —I yl L
WC-2 _
3
FD-1;, 1
771
Tf—
Im
1/2n I j —
2rr
211
LAV-1 3" l�P TO VTR
f
II
1" DN
ENLARGED TOILET ROOM PLAN 2101211
LAV-1
2p�l
WC-2
� _-
4 SCALE:
1/4" =1'-0"
LAV 1
1263
_iwc-2
2"
Ir
2" DN
3/4" DN
ENLARGED TOILET ROOM PLAN 2021203 3 SCALE:
1/411-1 V.011
4
3
y4n
-r T
� — 3"
J
3" \
E
2" FD-1I
j IWC-2) I I 1
LA' 21 , I
_ �n177—�
--�
;' _ R R-1 R 1 f
wC— (—" DF-2
FD-1 2
TECH 91�ET
j I I 2
LAV-2 I, LAV 2
IF
A•J
E
COPYRIGHT NOTICE
THIS LAYOUT/DESIGN IS A
COPYRIGHTED WORK OWNED BY
COMFORT SYSTEMS USA
(NORTHWEST), INC. ("COMFORT
SYSTEMS NORTHWEST") AND
COMFORT SYSTEMS NORTHWEST
HEREBY RESERVES ITS RIGHT TO
PREVENT UNAUTHORIZED
COPYING, PUBLICATION OR USE
OF THIS LAYOUT/DESIGN AND TO
OBTAIN DAMAGES THEREFORE.
•
•
0 J
0
z.:
N
00
Q �
C
= 0
o z
o p
co
lir-
N o
L1J
O
o
W%,m,H
w
tz
U)
w
m
Cn co
N =
az
�o
Y OF-
N
O Q
N
LL Co
LL Co
0 co
W Q
W
Lu
W F-
p
W
�w
��
00
zm
O
Q LL
��
J
o
U
�
&
co
SIGNED: 8/11 /2017
REVISIONS
0. ISSUE FOR PERMIT 8/11/2017
DESIGNED
CSUSA NW / EE
CHECKED
CSUSA NW / SAL
08/11 /2017
tOB ilillUBER
11 .,
SHEET TITLE
ENLARGED
PLUMBING PLANS
1A01�4i,lI161140
rarllll�
COPYRIGHT NOTICE
ROOF
PARKING DECK
(2,702 SQ. FT)
3" RD ORD 3"
1 1
THIS LAYOUT/DESIGN IS A
COPYRIGHTED WORK OWNED BY
COMFORT SYSTEMS USA
(NORTHWEST), INC. ("COMFORT
SYSTEMS NORTHWEST") AND
COMFORT SYSTEMS NORTHWEST
RESERVES ITS RIGHT
(2,598 SQ. FT.) (3,687 SQ. FT.) (28 SQ. FT.) (3,170 SQ. FT.) (3,209 SQ. FT.) HEREBY PREVENT UNAUTHORIZED TO
COPYING, PUBLICATION OR USE
3" RD ORD 3" 3" RD ORD 3" 3" RD ORD 3" 3" RD ORD 3" 3" RD ORD 3" OF THIS LAYOUT DESIGNAND TO
1 1 1 1 1 1 1 1 1 1 ROOF
OBTAIN DAMAGES THEREFORE.
AT g"-/FT AT g--/FT AT g-"/FT "`^' ""'" 'v "
AT HORIZONTAL
(2,252 SQ. FT)
3" RD ORD 3"
1 1
(160 SQ. FT)
3" RD ORD 3"
1 1
SCALE: NONE
NOTE: ALL UNDERGROUND RWL PIPE
SIZED TO RUN AT A SLOPE OF $"
PER FOOT UNLESS NOTED
OTHERWISE.
0)
ag
LL
OW
Im
rn
Q
Cr)
O
O
M
N
w
H
W O
O
> O
Q Z
O T
w
W N
Lu
U J �
r
00o
N
O
ti
00
SIGNED: 8/11 /2017
O
0
H
W
uj
m
_! _
N
ob ry
=) O
L
O T
z>-
U ry
J O
LL
�o
C)
(3,023
3" RD
1
SQ. FT)
ORD 3"
1
(2,082
3" RD
1
SQ. FT)
ORD 3"
1
(471 SQ. FT)
3" RD ORD 3"
1 1
(2,809
3" RD
1
SQ. FT)
ORD 3"
1
(2,082
3" RD
1
SQ. FT)
ORD 3"
1
(1,906
3" RD
1
SQ. FT)
ORD 3"
1
(2,351
3" RD
1
SQ. FT)
ORD 3"
1
(2,146
3" RD
1
SQ. FT)
ORD 3»
1 PARKING DECK
REVISIONS
0. ISSUE FOR PERMIT 8/11/2017
i i V 11 Y J 1 I i V I V I V V V `T, V J I J \4 . 1 I. j 1 1 \"1 V .J 11 1 V 1 Y 1 V V I i \/11 Y J 1 I i V i Y Ili V 1 1 \!11 7 J 1 1 1 V 1 Y 1 V T
AT HORIZONTAL AT HORIZONTAL AT HORIZONTAL AT HORIZONTAL
NOTE: ALL UNDERGROUND RWL PIPE
SIZED TO RUN AT A SLOPE OF
PER FOOT UNLESS NOTED
OTHERWISE.
DESIGNED
CSUSA NW i EE
CHECKED
CSUSA NW / SAL
AT DATE
FT 08/11/2017
JOB NUMBER
117036
SHEET TITLE
STORM WATER
RISER DIAGRAM
SHEET NUMBER
P200
SCALE: NTS
CONCRETE SURFACE OR FLOOR
COVERING AS REQUIRED
6"0 NOMINAL ROUND TOP FLOOR DRAIN
SEE SCHEDULES AND PLANS FOR
LOCATIONS, SIZES AND OPTIONS
FD-1 FINISHED FLOOR LINE
TOP FLANGE
CONCRETE SURFACE OR FLOOR
COVERING AS REQUIRED FS-1
FS-2
4
DRAIN
FITTING TYPE AS
REQUIRED TO SUIT
P-TRAP
SIZE PER PLAN
FLOOR SINK, 12" X 12" X 6" DEEP, TYP
SEE SCHEDULES AND PLANS FOR
LOCATIONS, SIZES AND OPTIONS
DOME STRAINER FINISHED FLOOR LINE
-----------------------4------------
4
�— FITTING TYPE AS REQUIRED
TO SUIT PIPE MATERIALS
4 FLOOR SINK DETAIL
P4.1 SCALE: NONE
TYPICAL BRANCH LINE
WATER HAMMER
ARRESTOR
2" OR 3" P-TRAP (TYP)
UNLESS NOTED OTHERWISE
PDI SYMBOL
PDI "A"
PDI CERTIFIED WATER HAMMER ARRESTOR SCHEDULE
PDI SYMBOL
A
B
C
D
E
F
FIXTURE UNIT
1-11
12-32
33-60
61-113
114-154
155-330
1. PREFERRED TO INSTALL WATER HAMMER ARRESTORS AT THE END OF BRANCH
LINE BETWEEN THE LAST TWO FIXTURES SERVED.
2. THE SUM OF FIXTURE UNIT RATING OF UNITS OVER 20' IN LENGTH SHALL BE
EQUAL TO OR GREATER THAN THE DEMAND OF THE BRANCHES.
CONCRETE SURFACE OR FLOOR
COVERING AS REQUIRED
NICKEL BRONZED SCORATED CLEANOUT TOP
W/THREADED CO PLUG
4"0 ROUND CLEANOUT HOUSING
FCO-1 / r FINISHED FLOOR LINE
4 n ° 4
a n
n
a a n
4
FITTING TYPE AS REQUIRED TO SUIT
i
1 /8 BEND DRAIN FITTING
WYE BRANCH
DRAIN PIPE
FLOW
2 FLOOR CLEANOUT DETAIL
P4.1 SCALE: NONE
SPOUT BRACE
HW/CW SERVICE FAUCET WITH
VACUUM BREAKER
HOT COLD
5 MOP SINK DETAIL
�-l
SCALE: NONE
HIGH EFFICIENCY CONDENSING
GAS FIRED WATER HEATER, TYP.
CONDENSATE OUTLET
BY GRAVITY
OPTIONAL OVERFLOW
BY-PASS
SPOUTI WITH HOSE END
AND PAILHOOK
FINISHED FLOOR LINE
MOP SINK, SEE SCHEDULES
FOR SPECIFICATIONS
COMBUSTION AIR AND
EXHAUST VENTING
go]ly, mil Kai ok
FLOOR DRAIN 1 /2"0 CORROSION
TO SAN SEWER RESISTANT WASTE PIPING
IN -LINE CONDENSATE NEUTRALIZATION KIT TO
TREAT CONDENSATE DISCHARGE TO SEWER
SYSTEM FROM CONDENSING GAS APPLIANCES.
NORITZ NC-1 SERIES OR OTHER APPROVED.
10' MIN FROM ANY
FRESH AIR INTAKES
COORDINATE WITH
MECHANICAL PLANS
INTERIOR WALL SYSTEM, SEE ARCH
PLANS FOR TYPE AND THICKNESS
CHASE
SANITARY WASTE PIPING
SLEEVE THRU WALL
WALL COVER PLATE
CHROME W/SCREW
WCO-1 4" MIN ABV
FLOOR LINE
3 WALL CLEANOUT DETAIL
P4.1 SCALE: NONE
2"0 MIN VENT
VENT CAP COUNTER
FLASHING
ROOF VENT FLASHING
FINISHED ROOF
VENT PIPE SIZE AS
NOTED ON PLANS
MIN
;TEND FLASHING
i" MIN ALL SIDES
6 VENT THROUGH ROOF DETAIL
P4.1 SCALE: NONE
2" EARTHQUAKE SHUTOFF VALVE
KOSO 314 OR EQUAL
BUILDING GAS PIPING
POINT OF CONNECTION
SHUT-OFF VALVE BY PSE
SV-1 101 GAS PRESSURE
. _ REGULATOR BY PSE
- (---------------
1
2 PSIG DELIVERY °�
TO BUILDING SUPPLY
3,433 CFH -
CONNECTED LOAD
GAS METER BY �-
PSE, TYPICAL II
la
FINISHED GRADE J�
1. SEE NATURAL GAS USAGE SCHEDULE TRACER WIRE
FOR QUANTITY USED BY FACILITY.
GAS PIPE RISER BY PSE
COPYRIGHT NOTICE
THIS LAYOUT/DESIGN IS A
COPYRIGHTED WORK OWNED BY
COMFORT SYSTEMS USA
(NORTHWEST), INC. ("COMFORT
SYSTEMS NORTHWEST") AND
COMFORT SYSTEMS NORTHWEST
HEREBY RESERVES ITS RIGHT TO
PREVENT UNAUTHORIZED
COPYING, PUBLICATION OR USE
OF THIS LAYOUT/DESIGN AND TO
OBTAIN DAMAGES THEREFORE.
O
o
V
w
co
w
m
CIO 00
N =
ry
O7
d'
Qz
�o
N
O Q
O N
2 :D
°e_�
co
ui Q aoUJ
W c j
w co
p
_j
Ed
ui co
ry
W
IL�
oo
2: co
Qo
�0
o
v
O�bm
00
SIGNED: 8/11 /2017
REVISIONS
0. ISSUE FOR PERMIT 8/11/2017
DESIGNED
CSUSA NW i EE
CHECKED
CSUSA NW / SAL
08/11/2017
JOB NUMBER
117036
SHEET TITLE
PLUMBING
DETAILS
SHEET NUMBER
;61
9 GAS SERVICE DETAIL
P301 SCALE: NONE
COPYRIGHT NOTICE
WSEC TABLE C404.3.1
PIPING VOLUME AND MAXIMUM PIPING LENGTHS
NOMINAL PIPE SIZE
(INCHES)
VOLUME
(LIQ OZ PER FT)
MAXIMUM PIPE LENGTH (FEET)
PUBLIC LAV FAUCET
OTHER FIXT & APPL
1 /4"
0.33
6
50
5/ 16
0.5
4
50
3/8
0.75
3
50
1 /2
1.5
2
43
5/8
2
1
32
3/4
3
0.5
21
7/8
4
0.5
16
1
5
0.5
13
1-1/4
8
0.5
8
1-1/2
11
0.5
6
2" OR LARGER
18
0.5
4
2015 WASHINGTON STATE ENERGY CODE SECTION C404.3:
1. DOMESTIC HOT WATER SYSTEMS SHALL BE DESIGNED TO COMPLY WITH MAXIMUM PIPE
LENGTHS OR VOLUMES AS REQUIRED BY 2015 WSEC SECTION C404.3 AND TABLE C404.3.1.
1 S)vKVlut
P302 J SCALE: NONE
TI 1rr%i if%L /rTr r%
EXTERIOR WALL SYSTEM.
SEE ARCH PLANS FOR TYPE
AKIM ri nnvnireln
SHUT—OFF V,
3/4" DOMESTIC (
WATER SUf
STRAINER
RECIRC PUMP
CIRCUIT BALANCING VALVE
FINISH
(IN
2 t_X I t:KIL
P302 SCALE: NONE
AQUASTAT
HOT WATER RETURN
YDRANT
37), 3/4" HOSE
IECK BACKFLOW
THIS LAYOUT/DESIGN IS A
COPYRIGHTED WORK OWNED BY
COMFORT SYSTEMS USA
(NORTHWEST), INC. ("COMFORT
SYSTEMS NORTHWEST') AND
COMFORT SYSTEMS NORTHWEST
HEREBY RESERVES ITS RIGHT TO
PREVENT UNAUTHORIZED
COPYING, PUBLICATION OR USE
OF THIS LAYOUT/DESIGN AND TO
OBTAIN DAMAGES THEREFORE.
HOT WATER SUPPLY COLD WATER SUPPLY
CHECK VALVE (iYP) :3
T&P RELIEF VALVE T" L EXPANSION TANK ow
�}�ISOLATION VALVE (iYP)��=
r
ELECTRIC WATER HEATER w : 41
�4
Ra a mw mI
■ 1 ,: ill W.1wo
TO EQUIPMENT, REFER TO
PLANS AND SCHEDULES
FOR LOCATIONS
1 /2 CW
MIN 18" AFF
MAX 60" AFF
SEISMIC STRAP (TYP)
INSULATED PAD ON CONCRETE
DOMESTIC WATER HEATER (ELECTRIC -
SCALE: NONE
FLOOR DRAIN
1 /2" CW (FROM BLDG
WATTS REDUCE PRESSURE DOM DISTRIBUTION)
BACKFLOW PREVENTER
1/2" #LF009QTD
RPBP
RP-2 WALL BRACKET, AS
RP-3 AIR GAP FUNNEL REQUIRED
RP-4
ROUTE TO NEAREST
FLR DRAIN
V V O � D C G�JC O ti' ✓ 4 V G c' G` +i V O v O O G
1. THIS PLAN SHOWS THE GENERAL ARRANGEMENT OF PIPING AND VALVE.
COORDINATE PLACING OF ALL RPBP WITH KITCHEN EQUIPMENT AND SPACE
COORDINATION.
w
H
O
O
O
�O
H N
���
Q z ,
)
W�L0
W N
U J �
ry F_
00
N
O
ti
O
r-
SIGNED: 8/11 /2017
REVISIONS
0. ISSUE FOR PERMIT
DESIGNED
CSUSA NW / EE
CHECKED
CSUSA NW / SAL
DATE
08/11/2017
JOB NUMBER
117036
O
0
co
Lu
m
_! =
N �-
co ry
O OQ
u�
OW
SO cf)
w } cn
U ry,
J O
O
U
t
8/11 /2017
SHEET TITLE
PLUMBING
DETAILS
�• 1:
P302
4 LUNL t
P302 SCALE: NONE