Loading...
0584_001.pdfGEOTECH CONSULTANTS, INC. Silvia Heldridge 930 Glen Street Edmonds, Washington 98020 via email: sheld6d- e a hotmail.com 2401 loth Ave E Seattle, Washington 98102 (425) 747-5618 January 21, 2019 JN 18381 sioe YY\ Subject: Response to City of Edmonds Stormwater Review Comments Proposed Single -Family Residence 923 Glen Street Edmonds, Washington Permit No. BLD20181405 Reference: Stormwater Review Comments, Heldridge SFR, City of Edmonds Engineering Division, November 26, 2018, Geotechnical Engineering Study, same site, Geotech Consultants, Inc., September 12, 2018. Dear Ms. Greene: We prepared a geotechnical engineering study for this project dated September 12, 2018 as referenced above. In our study, we recommended that onsite infiltration of collected stormwater not be used on the subject site. We recently received the above -referenced, November 26 review letter from the City of Edmonds requesting clarification of our infiltration recommendations. Below we have included the three comments that were included in the review letter (in bold and italics), and directly thereafter we have given our response to each comment. a. Update boring logs to better explain/Identify the separate soils layers encountered and where soils become infeasible for infiltration; currently, the borings appear to suggest a uniform prol`tle which does not match with the restrictive layers described at various depths in the text. Updated Test Pit Logs intended to better distinguish the separate soil layers are attached to this letter. The portion where the soils became cemented, which is the significant soil change in the test borings, is now more clearly delineated. b. Revise text to clarify, explain, and/or describe the cementation observed and impact on Infiltration (i.e.. Why is this not the material which is "typically suitable for ingltration'g. The soil that is noted as being cemented, as described in the text of the study the test pit logs included in the study, has been glacially -compressed; this has caused the dense condition of the underlying sand and the cementation. The glacial compression has resulted in fewer and smaller void spaces between the sand particles, making the soil much less permeable. As discussed in the General section of our study, we also observed mottling above the dense underlying sand indicative of groundwater becoming perched on top of the less permeable underlying soils during the wet winter months. As a result, water ihtrodupedi Heldridge January 21, 2019 JN 18381 Page 2 to the upper soils will likely percolated downwards, until it becomes perched on top of the dense, cemented, soils below; the perched water will then migrate downgradient on top of the glacially -compressed soils towards the existing basement beneath the northern neighboring residence. c. Update text to explain/describe why Test Pit 4 (i.e.. southern portion of lot) was not a viable location for infiltration; current infeasibility justification focuses on impacts specific to north portion. The dense, cemented, glacially -compressed sand was encountered below a depth of 1.5 feet below the ground surface in Test Pit 4 on the southern portion of the subject property. Furthermore, we understand that the new residence on the subject site will have a basement. Stormwater infiltrated on the southern end of the site near Test Pit 4, upslope of the proposed residence, will become perched on the shallow, cemented, glacially - compressed sand and migrate towards the new basement foundation walls. Thus, we believe that infiltrating in the area of Test Pit 4 is not appropriate. If you have any questions this letter, or if we may be of further service, please do not hesitate to contact us. Respectfully submitted, GEOTECH CONSULTANTS,. INC. Adam S. Moyer Gegtk�lj�ical Engineer X1171 WAS YY �O 8 ols SSf O N.4L Ur�O� 01/21/19 D. Robert Ward, P.E. Principal Attached: Test Pit Logs cc: Ryan Rhodes Architecture - Christine Greene via email. christine()-ryanrhodesdesi ns.com ASM/DRW:kg GEOTECH CONSULTANTS, INC. 61, 10 5 10 `11 ado 0 G° J TEST PIT 1 Description over: crown SAND with gravel, roots, and trace silt, fine- to medium -grained, dry, loose -reduced organics content -reduced silt content, becomes gray -brown, moist, medium -dense Gray SAND, fine to medium -grained, cemented, very moist, dense (glacially -compressed) * Test Pit terminated at 5.5 feet on August 15, 2018. * No groundwater seepage was observed during excavation. * No caving observed during excavation. TEST PIT 2 J50 Description Grass and topsoil over: FILL Dark -brown SAND with silt, roots, gravel, and plastic and wood debris, fine-grained, dry, Rust -brown SAND with trace gravel, fine- to medium -grained, moist, loose Sp 11 -becomes medium -dense Gray with heavy rust -mottling, SAND with trace gravel, cemented, very moist, dense (glacially -compressed) * Test Pit terminated at 5.5 feet on August 15, 2018. * No groundwater seepage was observed during excavation. * No caving observed during excavation. GEOTECH CONSULTANTS, INC. TEST PIT LOG 923 Glen Street Edmonds, Washington Job Date: Logged by: plate: 18381 Jan, 2019 1 ASM 1 3 OeQ�r` �Go�tie���aao �e JAGS 4+ 10 1 J�z\,lc 5 10 TEST PIT 3 Description Grass and topsoil over: Brown SAND with silt, gravel, and brick and concrete debris, fine-grained, dry, loose (FILL) Rust -brown SAND, fine-grained, moist to dry, loose -increased gravel content, becomes brown, moist, medium -dense * Test Pit terminated at 6.0 feet on August 15, 2018. * No groundwater seepage was observed during excavation. * Caving observed between 0 and 4 feet during excavation. TEST PIT 4 Description Topsoil over: Rust -brown SAND with gravel, fine- to medium -grained, moist, loose Rust -brown gravelly SAND, fine to medium -grained, cemented, medium -dense to dense (glacially -compressed) * Test Pit terminated at 4.5 feet on August 15, 2018. * No groundwater seepage was observed during excavation. * No caving observed during excavation. GEOTECH CONSULTANTS, INC. TEST PIT LOG 923 Glen Street Edmonds, Washington Job Date: Logged by: Plate: 18381 1 Jan. 2019 1 ASM 1 4