Loading...
06-0660-1.doc City of Edmonds TH 121 5 AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Plan Review Corrections Plan Check : Date: # 2006-0660 July 5, 2006 Project Name/Address: 717 Alder ST Contact Person/Address/Fax: Erik Bredberg/624 Edmonds Way, Edmonds Wa 98020/425-778-5400/Fax:425- 778-3032/e-mail:erikb@adshapiro.com Reviewer: Jaime HawkinsDivision:Engineering During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed: 1.Please show the required Temporary Erosion and Sediment Control in the Site plan. Include Silt Fence (STD detail E1.1), Construction Entrance (STD detail E1.2), and Temporary Sediment Trap for Catch Basins (STD detail E1.3) in the Site plan. 2.In order to connect the proposed detention system to the City of Edmonds Storm system you shall install two type 1L catch basins in the City right of way, one catch basin in the north side of Alder St and the other in the south side intercepting the Storm system. Please show the required catch basins in the Site plan along with the invert and rim elevations. The minimum pipe diameter to be used in the right of way is 8-inches with a minimum cover of 2-ft. If the required cover cannot be met then Ductile Iron pipe shall be used. 3.You have not shown the side sewer or the sewer lateral servicing this lot. Please show the side sewer from the property to the house. Make to include a 6-inch clean out at the property line. This clean out shall be installed at final grade and with a locking cast-iron cover. 4.Please show the sewer lateral from the Sewer main to the property line. If one does not exist then, one shall be installed. Please verify with the Sewer Department at Public Works by dialing 425-771-0235. 5.Please show the water meter and the water service line from the meter to the house. The min. diameter for the water service line is 1-inch, if poly is used then, a 12-gauge tracer wire shall be taped to the line every 10-feet. 6.The proposed driveway cut shall be installed per standard detail E2.8, E2.13, and E2.26. 7.Please obtain, fill, and submit the required Traffic Impact Analysis. Please refer to the City of Edmonds Development Information handout #E82. DATE FAXED PAGE ____ OF ___ Please resubmit 3 copies of the revised plans/documents to a Development Services Coordinator. Please contact me at 425-771-0220 if you have specific questions regarding these plan corrections. DATE FAXED PAGE ____ OF ___