Loading...
06-0849 Plan Review Comments.pdfmem CITY OF EDMONDS • 1215" AVENUE NORTH • EDMONDS, WA 98020 ® m PHONE: 425.771.0220 • FAx. 425.771.0221 • WEB: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT: PLANNING • ENGINEERING • BUILDING March 5, 2007 Mr. Ben Holt Email: peoples@eskimo.com RE: PLAN REVIEW COMMENTS FOR PLAN CHECK # 2006-0849 HOLT SINGLE FAMILY RESIDENCE AT 1141 SEA VISTA PLACE Dear Mr. Holt: I have reviewed the above building permit application for the Planning Division and it was found that the following information, corrections, or clarifications will need to be addressed before review can continue: 1. Site Plan: Please make the following changes to the site plan: a. Label the front porch as covered. b. Provide labels to distinguish between the covered and uncovered portions of the deck on the rear of the house. c. Label the rectangle shown with a dashed line on the plans, which is located in the general footprint of the proposed residence_ I am unsure of what this line is showing_ d. Show and label the outline of the proposed eaves on the site plan. 2- Setbacks: Please show the shortest distances from the proposed residence to each of the property lines so that staff can verify that the residence meets the minimum required setbacks_ 3. Steep Slope: Please show the top .of the steep slope on the site plan and provide the distance from the top of the slope to the proposed residence. 4. Rockeries: Rockeries are not permitted to exceed three feet in height over original grade when located within the minimum required setbacks. Please provide top of wall and original grade elevations along all proposed rockeries at 5 -foot intervals in order to ensure that the walls will not exceed three feet over original grade where they are located within the minimum required setbacks. 5. Fence: The site plan states "remove/replace fence as required." Please show which portions of the existing fence are to be replaced and provide information on the height of the proposed fence from original grade and what the fence is to be made out of. 6. Height Calculations: Please make the following changes to the height calculations: a. Provide a new datum point for the height calculations. The datum point must be a fixed point (such as a manhole cover, fire hydrant, etc.) that will not change during construction. The proposed datum point must be changed because its location within the street is too dangerous for our Building Inspector to use. h. The portion of the upper floor deck that is uncovered should not be included in the rectangle used for the height calculations. Please move Points C and D of the height rectangle to the east so that they are in line with the westernmost wall of the residence (excluding up to only 30 inches of eaves). Please provide updated elevations for the new locations of Points C and D and update the height calculations as necessary. c. The elevations of Points B and D as shown at the corners of the height rectangle do not match the elevations for the corresponding points shown under the height calculations. Please make sure that the elevations shown on the four corners of the height rectangle match the elevations shown under the height calculations and make any necessary corrections to the height calculations. d. Correct the average grade and maximum height shown on the building elevations to reflect all changes made to the height calculations. 7. Lot Coverage: It is difficult to determine how the structural lot coverage was calculated. Therefore, please provide a breakdown of the lot coverage calculations on the site plan. The total lot coverage must include the area of the footprint of the residence, which includes the area of the portion of the main floor that cantilevers over the lower floor, as well as the area of the covered front porch, the storage area, and the area of the rear deck since the deck is over three feet in height. Covenant: Your building plans show a second kitchen in the lower floor of the proposed residence. Since the house is proposed to have a second kitchen, a covenant must be recorded at the County stating that you are aware that an Accessory Dwelling Unit (ADU) permit must be approved separately from this building permit application if you intend for a portion of the lower floor to act as a separate dwelling unit apart from the main residence. Even if you do not intend for the lower floor to act as an ADU, the purpose of getting this statement recorded is to protect any future owners from thinking that the house contains an approved ADU. I am enclosing the City's ADU handout as well as the covenant that must be recorded at the County. Please have the property owner(s) review and sign these materials. Note that signatures must be notarized and signed in black ink_ Also note that due to the County's restrictions on margins, the covenant must be printed on legal sized paper with a 3" top margin and 1" side and bottom margins. You may either get the covenant recorded at the County on your own for $32, or you may turn it in to the City to record it at the County for you for $47 (the County's $32 recording fee plus a $15 City surcharge fee). If you would like for a portion of the lower floor to act as an ADU, please contact me for the ADU permit application submittal requirements. Geotechnical Report: The geotechnical report by Dennis Bruce submitted with the permit application does not appear to address all of the report requirements set forth in Edmonds Community Development Code (ECDC) Chapter 23.80. Since the site contains a Landslide Hazard Area, it is necessary for the geotechnical report to meet the requirements of this chapter of the code, especially the report requirements addressed in Section 23.80.050. Please provide Mr_ Bruce with the current house plans and have him prepare an addendum to his initial report addressing the requirements of ECDC 23.80. This addendum should state that Mr. Bruce has reviewed ECDC 23.80 and the current house plans. The addendum must provide all necessary additional information so that the report meets the City's requirements pertaining to the proposed new residence. For example, in response to the requirements of ECDC 23.80.050.C.4, the report should provide a recommendation for the minimum building setback from the top of the steep slope, and in response to the requirements of ECDC 23.80.070.A.2, the report should provide certification that the development will not increase surface water discharge or sedimentation to adjacent properties beyond predevelopment conditions, the development will not decrease slope stability on adjacent properties, and the proposed alterations will not adversely impact other critical areas. 10. SEPA Review: Please provide the total quantities of cut and fill. If the total amount of cut or fill is proposed to exceed 500 cubic yards, SEPA review will be required and an environmental checklist and the associated fee must be submitted. Please submit three copies of your updated site plan (one of which must be 8.5 by 14 inches or smaller in size) and two sets of any updated pages of the building plans. Please make all submittals to a Development Services Permit Coordinator, Monday through Friday, 9:00 am to noon or 1:00 pm to 4:00 pm. If you have any questions, feel free to contact me at (425) 771-0220, ext. 1224. I look forward to working with you on this project. Sincerely, Development Services Department - Planning Division Jen Machuga Planner