During review of the subject submittal, it was found that the following information, corrections, or
clarifications would need to be addressed:
Site, Drainage and Grading plans shall present an accurate depiction of the existing and proposed structures,
utilities, contours, etc. You have not shown the actual locations of the already installed sewer, water, cable,
phone, rockery, etc in the Site and Drainage plans. Please provide the required information as needed.
Please show the infiltration system, catch basin, etc in the Drainage plan as shown in the approved
DO NOT RED LINE.
civils. Make sure to include invert and rim elevations.
DO NOT
Please show the roof tight line and the footing drain tight line connecting to CB #1.
RED LINE.
Show the water meter at the approved location per the approved civils. Also, please include the
water service line from the meter to house. If any non-traceable material is used then a 12-gauge
tracer wire shall be buried with the line and shall be grounded at ends, the meter and the house.
DO NOT RED LINE.
Show the already installed section of the side sewer from the property line at the street to the
DO NOT RED LINE.
house; make sure to include the clean-out in the driveway.
There is an existing rockery along the East, West, and South property lines. Please show the
rockery as existing along with top and bottom elevations. Is the rockery you have shown in the
Site and Drainage plans to be constructed? If not, please remove. If it is to be constructed, please
adjust your grading quantities as needed.
Per ECDC, 18.80.060.D. Driveway slopes shall not exceed 14 percent unless authorized by the
Public Works director. You are showing the driveway slope at 20 percent. Please adjust your
DATE FAXED (E-MAILED) 7/5/2017 PAGE__ OF ___
grade to meet the Code requirement of 14 percent and provide a driveway profile to verify the
driveway slope.
The grading quantities exceed 500 cubic yards. Please contact the Planning Division to get SEPA
determination started.
Please resubmit 3 copies of the revised plans/documents to a Development Services Coordinator. Please
contact me at 425-771-0220 if you have specific questions regarding these plan corrections.