06-113_7919-CyrusPl.pdf
CITY OF EDMONDS
CRITICAL AREAS RECONNAISSANCE REPORT
Site Location:Tax Acct. Number:
7919 Cyrus Place 27040700401700
Determination:Determination #:
Study Required CRA-2006-0113
Applicant:Owner:
Peter A. Whitney Peter A. Whitney
CRITICAL AREAS RECONNAISSANCE REPORT:STUDY REQUIRED (CRA-2006-0113)
During review and inspection of the subject site, it was found that the site may contain or be
adjacent to critical areas, including a Stream, Landslide Hazard Area, and Erosion Hazard Area,
pursuant to Chapter 23.40 of the Edmonds Community Development Code (ECDC). The
LIDAR map indicates erosion and landslide hazard potential, as the site slopes down generally
from east to west at slopes of approximately 32%, 47%, 58%, and in the northeast corner, at
approximately 88%. Also, it was found that Talbot Park creek is on or adjacent to the property.
The creek runs through a channel from east to west along the southern portion of the property.
GENERAL CRITICAL AREAS REPORT REQUIREMENTS
Critical Areas Reports identify, classify and delineate any areas on or adjacent to the subject
property that may qualify as critical areas. They also assess these areas and identify any
potential impacts resulting from your specific development proposal. If a specific development
proposal results in an alteration to a critical area the critical areas report will also contain a
mitigation plan. You have the option of completing the portion of the study that classifies and
delineates the critical areas and waiting until you have a specific development proposal to
complete the study. You may also choose submit the entire study with your specific
development application.
Please review the minimum report requirements for all types of Critical Areas which are
listed in ECDC 23.40.090.D. There are additional report requirements for different types of
critical areas (see below).
Note that it is important for the report to be prepared by a qualified professional as defined in
the ordinance. There are options on how to complete a critical areas study and an approved
list of consultants that you may choose from. You may contact the Planning Division for
more information.
General Mitigation Requirements for all Critical Areas are discussed in ECDC 23.40.110
through 23.40.140.
STUDY REQUIREMENT – EROSION HAZARD AREA
It appears that this property contains or is adjacent to an Erosion Hazard Area.
Erosion Hazard areas include Alderwood and Everett series soils on slopes of 15 percent or
greater, among others.
Landslide Hazard Areas are further defined in ECDC 23.80.020.A.
In addition to the general requirements for Critical Areas reports referenced above, specific
Critical Area report requirements for Erosion Hazard Areas (which are one of the
Geologically Hazardous Areas) are provided in ECDC 23.80.050.
Note that Stable Erosion Hazard Areas may have limited report requirements at the
director’s discretion. At a minimum an erosion and sediment control plan prepared in
compliance with the requirements in ECDC Chapter 18.30 shall be required.
- 1 -
DEVELOPMENT PROPOSALS ASSOCIATED WITH EROSION HAZARD AREAS
Development is restricted within an Erosion Hazard Area and must meet additional criteria.
For erosion hazard areas with suitable slope stability, an erosion and sediment control plan
prepared in compliance ECDC 18.30 will be considered to meet the Critical Areas “Study
Required” determination. The determination of “suitable slope stability” will be made by both
the Planning and Engineering divisions of the City of Edmonds.
In areas where the slope stability is not suitable, projects within Erosion Hazard Areas will
require a report by a licensed Geotechnical Engineer or other qualified professional.
Note that it is important for the report to be prepared by a qualified professional as defined in
the ordinance.
Report requirements are given in ECDC 23.80.050, and more generally in ECDC
23.40.090.D
Development standards are given in ECDC 23.80.060 and 23.80.070.
STUDY REQUIREMENT – LANDSLIDE HAZARD AREA
It appears that this property contains or is adjacent to a Landslide Hazard Area.
A Landslide Hazard Area is any area with a slope of forty percent (40%) or steeper and with
a vertical relief of ten (10) or more feet (except areas composed of consolidated bedrock).
Landslide Hazard Areas are further defined and illustrated in ECDC 23.80.020.B.
In addition to the general requirements for Critical Areas reports referenced above, specific
Critical Area report requirements for Landslide Hazard Areas are provided in ECDC
23.80.050.
DEVELOPMENT PROPOSALS ASSOCIATED WITH LANDSLIDE HAZARD AREAS
Development is restricted within a Landslide Hazard Area and its buffer.
Projects that will intrude into these areas will require a report by a licensed Geotechnical
Engineer.
The criteria that are applied depend on the amount that the buffer is reduced.
The buffer can be reduced to a minimum of ten (10) feet (with an additional 15’ building
setback per ECDC 23.40.280) if a report is prepared that meets the standards listed in
ECDC 23.80.050). The alteration must also meet the requirements listed ECDC 23.80.060.
In addition, proposals to reduce the buffer to less than ten (10) feet must comply with the
design standards listed in ECDC 23.80.070.A.3.
- 2 -
REPORT REQUIREMENTS – STREAMS
“Talbot Park Creek” or its tributary is on or near the subject property.
Streams are areas where surface waters produce a defined channel or bed which
demonstrates clear evidence of the passage of water. Streams need not contain water year-
round.
Streams are regulated as types of Fish and Wildlife Habitat Conservation Areas.
Streams are classified according to whether or not they run year round and whether or not
they support fish populations according to the classification system listed in ECDC
23.90.010.A.1.
The minimum buffer widths for streams vary depending on the type of stream and are listed
in ECDC 23.90.040.D.1.
In addition to the general requirements for Critical Areas reports referenced above, specific
Critical Areas report requirements for Fish and Wildlife Habitat Conservation Areas are
provided in ECDC 23.90.020.A to C and additional technical information requirements for
streams are listed in ECDC 23.90.020.D.
DEVELOPMENT PROPOSALS ON A SITE WITH A STREAM
Development proposals that encroach into streams or their buffers or building setbacks may be
allowed through the approval of certain processes.
The width of a stream buffer may be reduced through buffer enhancement if through the
review of a Stream Buffer Enhancement Plan that meets the specific requirements
referenced in ECDC 23.90.040.D.2. The maximum amount that a buffer can be reduced
through buffer enhancement is 50%.
A buffer may also be modified through a process called buffer averaging. The criteria
applied to buffer averaging are listed in 23.90.040.D.2. The maximum amount that the
buffer width can be reduced at any single location through buffer averaging is 50%.
Development proposals that propose encroachments into buffers beyond what is allowed
through the above methods require a Critical Areas Variance or a Reasonable Use
Exception. If you think that you have a proposal that may require one of these processes,
please contact a Planner for more information.
ALLOWED ACTIVITIES
Certain activities are allowed in or near critical area buffers as specified in ECDC 23.40.20. If
you have any questions about whether your proposed development qualifies as an allowed
activity, please contact a Planner for more information.
EXEMPT DEVELOPMENT PROPOSALS
Certain development proposals may be exempt from Critical Areas Requirements (ECDC
23.40.230). If you think that a specific development proposal may be exempt, contact a Planner
for more information.
Gina Coccia, Planner August 17, 2006