Loading...
062818 KRAZAN INSPECTION REPORT.pdfPage 1 of 1 1iL ID -.d F6 D 6MOUNW. Imam 1 Z Ann" —. Kf ;afl Field Report NO.: 09618282DFR6282018DK DATE: 6/28/2018 Set Count: CONTRACTOR: Westerly PROJECT #: 09618282 PERMIT #: PROJECT: Brackett's Corner INSPECTOR: Don Keller LOCATION: 2121' St. SW & 80 Ave JURISDICTION: Edmonds KA P.M.: WEATHER: TEMP: Observed the placement of 5/8" threaded rod at relocated hold down locations Lots #5,8,9,11,12,13,14. Holes drilled 10" deep x'/4" round and cleaned as per manufacturer's recommendation. Threaded rod epoxy grouted with counter clockwise twisting motion to remove air. Simpson ATXP Exp. 2/10/19. Reference: SS S#5151203 dated 6/12/18. Lot 5 BLD 2016 0603 Lot 8 BLD 2016 0606 Lot 9 BLD 2016 0609 Lot 11 BLD 2016 0611 Lot 12 BLD 2016 0612 Lot 13 BLD 2016 0613 Lot 14 BLD 2016 0614 Reviewed B 1--JASTM Test #: Asset Number(s): To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements. Superintendent/Representative: Technician: Offices Serving the Western Vnited States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 -rhe information provded on this sport is prepared for the esclusita use of the client This sport map not be reproduced in any format o 11—a dtc ,.nttcn of the d,u,i .u;,t K-- & Av.—.,lc; l hr. rrlwn: indreat" our inspectors observation and testing results based on site conditions and contractor activities. This information issubjectto rr,r,. pr,•,r w fill-bmmel By sit:r����e th,c rclnn. ,nrr mq,:aor �r+, n,n ac.cM rcspanibilily for W idily of nxuh, The ssmc information has been provided by others on site