06-46 michel plt.doc
Name: Michel Construction File No.: S-06-46
th
Reviewed by: Vicinity: 9009 196 St SW
Engineering Division date
A 5.00 foot street dedication is required X
Provide all easements as needed. X
All lots shall share a private access driveway X
Private access easements shall be a minimum of 15.00 feet in X
width
th
196 St SW shall be widened to provide for a minimum 12’ X
lane width for the westbound travel lane, from the painted
centerline to the face of curb.
Construct 18” concrete curb and gutter along the property X
frontage.
Private driveway shall be paved a minimum of 12.0’ wide plus X
18” asphalt thickened edge. A 6” concrete extruded curb may
be used
Slope of private driveway shall not exceed 14%. X X
Provide on-site turn around to City Standards. X
Construct 5’ wide sidewalk along property frontage. X
N/A
N/A
Install a 4” storz adapter on the existing fire hydrant. X
Provide water service to each lot. X
Connect to public water system. X X
Provide new sanitary sewer service to each lot X
Connect to public sewer system X X
C:\\Users\\cockrum\\AppData\\Local\\Temp\\06-46 michel plt.doc_153083\\06-46 michel plt.doc form revised: 11/15/05
C:\\Users\\cockrum\\AppData\\Local\\Temp\\06-46 michel plt.doc_153083\\06-46 michel plt.doc form revised: 11/15/05
Provide storm sewer service to all proposed lots. X
Construct one storm detention system sized to provide X
adequate capacity for proposed single family dwellings and
access improvements in accordance with ECDC 18.30.
Connect to Public Storm system X X
Connect all new impervious surfaces to detention system. X X
Required for all new services X X
Submit a grading plan as part of engineered site plan. X X
Grading for foundations to be included with the building
permit only.
All signs shall be vinyl letters and to City Stds. No silk screen X
signs will be permitted
Provide Fire and aid address sign X
N/A
Required for all utility construction. X X
a) Plat showing lots, easements, legals, survey information X X
b) Legal documents for each lot X
c) Field stake lot corners (by professional surveyor) X
d) Field stake utility stubs at property lines. X
e) Clustered mailbox location per Postmaster X X
f) Maintenance agreements X
C:\\Users\\cockrum\\AppData\\Local\\Temp\\06-46 michel plt.doc_153083\\06-46 michel plt.doc form revised: 11/15/05
($ X
a) Storm System Development charge (access only)
)
b) Storm System Development charge (sfr) X
$428/lot
c) Sewer LID fees to be paid in full X
d) Sewer Connection fee (new lots only) X
$730/lot
e) Water meter fee (based on ¾”) X
$550/meter
f) Water Connection fee (new lots only) X
$908/lot
$ X
g) Traffic Impact Fee $840.72/lot
$860X
h) Plan Review fee
$ X
i) Plat inspection fee (2.2% of improvement costs)
ENGINEERING PROGRAM MANAGER, CITY OF EDMONDS DATE
The Engineering requirements have been completed and the subdivision can be recorded.
Authorized for recording by: Date: