Loading...
07-0246 Plan Review Comments.pdf CE ITY OF DMONDS th • 1215 AN•E,WA98020 VENUEORTHDMONDS P: 425.771.0220 • F: 425.771.0221 • W:www.ci.edmonds.wa.us HONEAXEB DSD: P•E•B EVELOPMENT ERVICES EPARTMENTLANNINGNGINEERING UILDING March 22, 2007 Martin Reimes Fax: (425) 377-8783 RE: PLAN REVIEW COMMENTS FOR PLAN CHECK # 2007-0246 WHITE ADDITION/REMODEL AT 831 NORTHSTREAM LANE Dear Mr. Reimes: I have reviewed the above building permit application for the Planning Division and it was found that the following information, corrections, or clarifications will need to be addressed before review can continue: Site Plan: 1.Please make the following changes to your site plan: a.Label the decks as existing or proposed and as covered or uncovered. Additionally, please specify if any of the decks are less than 3 feet in height over original grade. b.Show the outline of the upper floor where it cantilevers over the lower floor, including the portion of the upper floor that cantilevers over the garage to the south and to the west. c.Show the outline of the roof using a faint or dashed line that can be distinguished from the line used for the exterior walls of the residence. Rockeries/Keystone Block Walls: 2.Rockeries and retaining walls are not permitted to exceed 3 feet over original grade where they are located within the setbacks. Therefore, please provide top of wall and original grade elevations along the proposed rockeries/keystone block walls at 5-foot intervals to ensure that the walls do not exceed 3 feet over original grade where they are within the minimum required setbacks. Height Calculations: 3. Please make the following corrections to your height calculations: a.Show the datum point and provide its elevation on the site plan. b.The height rectangle should be expanded to include the portions of the upper floor that project over the lower floor. Uncovered decks can be excluded from the height rectangle, but all of the house should be included out to the external walls and excluding only 30 inches of eaves. Please redraw the height rectangle and update the elevations of the four corners. Additionally, the average grade and maximum height calculations will need to be updated. c.Show the updated average grade, maximum allowed height, and proposed height on the building elevations. Lot Coverage: 4.Lot coverage is defined as the total ground coverage of all buildings or structures on a site measured from the outside of external walls or supporting members or from a point 30 inches in from the outside edge of the eaves, whichever covers the greatest area. Since decks that are more than 3 feet over original grade are considered to be structures, they must be included in the lot coverage calculations. Please update the lot coverage calculations to include the entire footprint of the proposed addition (including the portion of the upper floor that projects over the lower floor), the decks over 3 feet in height, and the covered front porch. Please submit three copies of the updated site plan (at least one copy must be reduced in size) and only two copies of any affected sheets of the building plans. Please make all submittals to a Development Services Permit Coordinator, Monday through Friday, 9:00 am to noon or 1:00 pm to 4:00 pm. If you have any questions, feel free to contact me at (425) 771-0220, ext. 1224. I look forward to working with you on this project. Sincerely, Development Services Department - Planning Division Jen Machuga Planner