07-0686 Plan Review Comments1.pdf CE ITY OF DMONDS PLANREVIEWCOMMENTS PLANNINGDIVISION 425.771.0220 DATE: September 10, 2007 TO: Valerie Sargent vsargent@weberthompson.com FROM: Kathleen Taylor, Associate Planner RE: PLAN CHECK #S 2007-0686, 2007-0685 & 2007-0331 POINT EDWARDS BLDG 10 50 PINE ST On behalf of the Planning Division, I have reviewed the above building permit application. Please respond in writing to the following items and indicate the page number where the answer can be found: See next page. Rockery along South Property Line. 1. Thank you for providing the top and bottom of wall elevations for the existing rockery along the south property line. The plans indicate that the rockery will be replaced as needed. In regards to the replacement, please clarify if the top of wall will remain the same elevation as is existing. Please do so by red-lining the plans or providing a revised copies of the relevant pages. I need to verify that the new wall will not exceed the elevation of the existing wall. Previously, I stated that the new wall must meet the required setback requirements, but since an existing wall requires repair and/or replacement, setbacks will only be an issue if the new wall will exceed the height of the previous wall. FYI- Once you’ve responded to this item, the Planning Division will be able to sign off on related building permits BLD-2007-0685 & BLD-2007-0331. Compliance with the Parking Requirements. 2. I was not able to find the parking requirement calculations on the plans. If I overlooked the, I do apologize. If you did provide the information, just reference the page number. Otherwise revise the plans to show how the building complies with the Edmonds Community Development Code requirements. I’m confident it will comply, but it needs to be detailed on the plans. State how many studio, 1-bedroom, 2-bedroom, and 3- bedroom units that the building will have. The required parking is as follows: 1.2 spaces per studio, 1.5 per 1-bedroom unit, 1.8 per 2-bedroom unit, and 2.0 per 3- bedroom unit. Indicate in your response to the City what page the answer can be found. Height Calculations. 3. On sheet A1.2, the height calculations are shown based on the historical grade. Thank you so much for providing this. However, the SE corner is written as 139.0, but appears to be located between the 142’ and 144’ contours. Please provide the correction elevation for the SE corner of the height rectangle, and revise the height calculations accordingly. Then on sheets A3.0, A3.1, and A3.2, label the elevation views to include the average grade, the actual elevation, and the maximum allowed elevation. Landscape Plan. 4. The landscape plan for building 10 looks great. I just need one clarification. It was difficult to read what type of trees will be planted in the two planting beds in the parking lot. It appears that there will be two trees in each, but please clarify. Please make all submittals to a Development Services Permit Coordinator, Monday through Friday, 9:00 am to noon or 1:00 pm to 4:00 pm. Please provide one copy of the revised reduced site plan and two copies of all other revised pages. If you have any questions, feel free to contact me at 425.771.0220 ext 1223. I work a part-time schedule. If I am not available, please ask to speak with the planner on duty.