07-1216 Plan Review Comments.pdf�. CITY OF EDMONDS • 1215" AVENUE NORTH • EDMONDS, WA 98020 PHONE: 425.771.0220 • FAX: 425.771.0221 • WEB: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT: PLANNING • ENGINEERING • BUILDING January 30, 2008 Mr. Mike Johnson Email: mjhnsnwy@hotmail.com RE: PLAN REVIEW COMMENTS FOR PLAN CHECK # 2007-1216 SAFFOLD NEW RESIDENCE AT 8008 TALBOT ROAD Dear Mr. Johnson: I have reviewed the above building permit application for the Planning Division, and it was found that the following information, corrections, or clarifications will need to be addressed before review can continue: 1. Site Plan: It was noted that the upper floor projects over the main floor by approximately one foot on the northwestern side of the house. It is unclear if this is shown on the site plan. Therefore, Please show and label the outline of the portion of the upper floor that projects over the main floor on all copies of the site plan. 2. Datum Point: Please show and label the datum point used for your height calculations on all copies of your site plan. 3. Height Calculations: Per ECDC 21.40.0303, the height rectangle used for your height calculations shall be the smallest rectangle that will enclose all of the building, excluding a maximum of 30 inches of eaves. It appears that the height rectangle used for your height calculations included some of the eaves. Additionally, it is unclear of the height rectangle includes the portion of the upper floor that cantilevers over the main floor on the northwestern side of the house. Therefore, please update your height rectangle to include the outermost walls of the residence, but exclude up to 30 inches of eaves. Additionally, please update the elevations of the four corners of the height rectangle, and update the height calculations shown on the site plan and building elevations accordingly. 4. Fence: Your site plan shows a 6' cedar fence. Please label this fence as existing or proposed. 5. Geotechnical Report: Please submit a geotechnical. report by a qualified geotechnical engineer in support of the proposed building permit that meets the report requirements of Edmonds Community Development Code (ECDC) Chapters 23.40 and 23.80, particularly Sections 23.40.090, 23.80.050. Additionally, the geotechnical report must address Section 23.80.070,A.2, by stating that the proposed work will not increase surface water discharge or sedimentation to adjacent properties beyond predevelopment conditions; the development will not decrease slope stability on adjacent properties; and such alterations will not adversely impact other critical areas. 6. SEPA Review: The Engineering Division's review of your proposal estimated the grading to be 490 cubic yards. Note that if grading exceeds 500 cubic yards, SEPA review will be required. Please contact the Planning Division for SEPA review procedures if you find that you will be exceeding 500 cubic yards of grading, 7. "Future Wet Bar": Sheet A4 of your building plans indicate a "future wet bar" within the proposed recreation room. Do you plan to stub the plumbing to this area with the subject application? If so, please indicate this on your plans. If not, please remove the "future wet bar" from your plans since it is not a part of this application. Please note that a separate building permit will be necessary if you plan to add the wet bar in the future. Additionally, an Accessory Dwelling Unit (ADU) covenant may be required when you propose to add the wet bar to ensure that the lower floor will not be used as an ADU without the appropriate land use approvals. Please make all submittals to a Development Services Permit Coordinator, Monday through Friday, excluding Wednesdays, between 5:00 am and 4:30 pm. If you have any questions, feel free to contact me at (425) 771-0220, ext. 1224. I look forward to working with you on this project. Sincerely, Development Services Department - Planning Division Jen Machuga Planner