074219.001-1 Insulated Metal Panel Backup Wall Assemblies REVISED_NBBJ-PAAN (2).pdfCONTRACTOR SUBMITTAL ISSUE TO NBBJ DATE ISSUED Apr 30, 2015 COMPANY NBBJ 223 Yale Avenue North Seattle, WA 98109 PHONE / FAX (206) 223-5555 PROJECT NUMBER 100822.06 PROJECT NAME SMC Edmonds ACC ATTENTION: Barb Gipple NBBJ Submittal Number 169-074219-1 GC Submittal Number 169-074219001-1 SPEC. PARAGRAPH: SPEC. DESCRIPTION:Insulated Metal Panel Backup Wall Assemblies SPECIFIC ITEM:Insulated Metal Panel Backup Wall Assemblies CONTRACTOR ISSUED ON:Apr 30, 2015 DATE REQUESTED BACK:May 15, 2015 DATE RECEIVED @ NBBJ:May 1, 2015 DATE DUE BACK TO CONTRACTOR:May 14, 2015 DATE RETURNED BY NBBJ: ITEMS TRANSMITTED SENT VIA REVIEW ACTION Partially approved as noted REVIEW NOTE COPIES GC REMARKS NBBJ COMPOSITE RESPONSE Entered By: Andris Lapins Entered Date: Wednesday, May 13, 2015 7:43 AM Approved as noted per attached comments. Please provide the following: Confirmation letter from the manufacturer stating that the installers deviations from recommended details are acceptable and will not adversely affect system performance or warranty. PLEASE NOTE: Previously reviewed information not reviewed with this submittal. ISSUED BY Joe Eagle PHONE / FAX: (206) 682-7770 CONSULTANTS REPRESENTED Page 1 of 2 5/13/2015https://secure1.nbbj.com/CATools/Data/SubForm.aspx?SubmittalID=130456&Msg=save 05/13/15 EMAIL: JOE.EAGLE@SELLEN.COM COPY TO: Dan Schnebele Mark Bucek Scott Solberg NBBJ Amy Frerker NBBJ Andris Lapins NBBJ Michael Howatt ELECTRONIC ATTACHMENTS Page 2 of 2 5/13/2015https://secure1.nbbj.com/CATools/Data/SubForm.aspx?SubmittalID=130456&Msg=save SUBMITTAL FOR APPROVAL 7039. - SWEDISH/EDMONDS-AMBULATORY CARE CENTER 1 | Page Submittal #: 169 -074219.001 Rev#: 1 Priority: HOT Date: 04/30/2015 To: MICHAEL HOWATT From: JOE EAGLE NBBJ SELLEN CONSTRUCTION CO., INC. 223 Yale Ave 227 WESTLAKE AVE N Seattle, 98109 SEATTLE, WA 98109 Originator: NORTHSHORE SHEET METAL INC Description: Insulated Metal Panel Backup Wall Assemblies We are transmitting the following Submittal Package item(s) for your review in accordance with the contract specifications. Please review and respond to: JOE EAGLE, by: 5/15/2015. Additional Notes: Item Number Spec Section Description Details Notes 169.002. 074219 Insulated Metal Panel Backup Wall Assebmlies Product Data, Shop Drawings, Coursing Layout, Performance Data, Panel to Panel joint detail, cc: REVIEWED WITH CORRECTIONS NOTED. THIS REVIEW DOES NOT RELIEVE THE SUBCONTRACTOR OR MATERIAL SUPPLIER FROM RESPONSIBILITY FOR ERRORS OR DEVIATIONS FROM DRAWINGS & SPECIFICATIONS. SELLEN CONSTRUCTION CO. GENERAL CONTRACTOR Submittal: 074219001-1 Insulated Metal Panel Bac By: joee Date: 04/30/2015 KarrierPanel™ Insulated Roof & Wall Panels Universal Barrier Wall Solution 074219 Insulated Metal Wall Panels KarrierPanel™ 2 Is a cost effective universal barrier wall alternative solution to traditional multi-component wall systems. Comprising of a KS Series panel and integrated rail, KarrierPanel™is the ideal barrier wall to support secondary rainscreens systems such as metal or brick façades. KarrierPanel™is suitable for all building types in any climate, and combines the thermal benefits of lightweight insulated metal panels with the aesthetics of multiple façades. KarrierPanel™offers a simple more time efficient alternative to traditional multi-part façades, allowing the structure to be quickly insulated to ensure air and watertightness as soon as possible. Once installed the system provides 100% building envelope performance. For more information or to request a sample, email karrier@kingspanpanels.com. To view an animation of the KarrierPanel™ wall system, visit our YouTube Channel, Kingspan TV. Contents 3 KarrierPanel™Product Details 4 Design Flexibility 5 Build Speed 6 Thermal Performance 7 Sustainability 8 Testing and Approvals 10 Kingspan Service and Support 11 KarrierPanel™Projects 12 Construction Details 14 4 KarrierPanel™ Product Details Product Specification Cover Widths: 24” 30” 36” 42” (Standard) Panel Thickness: 2” 2 1/2” 3” 4” 5” 6” R-value: 7.5 per inch Panel Lengths: 6’-0” to 52’-0” Panel Joint: Double tongue and groove interlocking rainscreen joint Reveal Choice:3/8 reveal Exterior Face: 26, 24 or 22 Ga. Shadowline profiled embossed Galvalume®pre-painted steel Interior Face: 26, 24 or 22 Ga. Shadowline profiled embossed Galvalume®pre-painted steel Application: Vertical and horizontal Rail: Custom Kingspan KarrierRail ™ 5 Design Flexibility KarrierPanel™ can support a range of rainscreen finishes to compliment any architectural scheme. Unique KarrierRail™ KarrierPanel™utilizes a Kingspan designed unique rail. This stable and secure structural rail safely transmits positive loads from the multiple façades to the structural supports behind the insulated panels. Similarly, expansion fasteners (fab-loks) secure the exposed rail edge, ensuring that the system safely handles negative loads as well. The rail has been developed to fully integrate with Kingspan’s KS series panel joint. This rail system does not penetrate the air vapor barrier and enables multiple types of rain screens to be attached to the KarrierPanel™rail such as brick, single skin metal, and various other systems. Brick Rainscreen on KarrierPanel™ Metal Rainscreen on KarrierPanel™ Installation is quick, simple and easy, as the rail is installed during normal panel installation, and is secured using standard panel fasteners in a one step procedure. The standard rail configuration is 16 gauge Galvalume®, 50 KSI steel. Available in various lengths with a 1, 2 and 3 inch bearing surface. Build Speed 6 Build Speed KarrierPanel™as a single component system increases speed of build, minimizes delays and the need for multiple trades. Typical multi-part façade system KarrierPanel ™System with Metal Single Element Rainscreen Single Component KarrierPanel™ Wall System Vs 1 ■Faster close-in and dry-in for reduced building costs. ■The single component system results in less labor time on-site and construction waste. ■Reduces delays in construction experienced with scheduling multiple trades. ■Increase in build speed allows faster project completion and reduces business disruption. Thermal Performance 7 Vs The insulated panel provides excellent thermal performance with high R-value and airtightness with an air, water and vapor barrier. Benefits of the KarrierPanel™Wall System Vs Traditional Built-up Construction: ■The single component KarrierPanel™wall system combines the superior thermal performance of IMPs with an air, water and vapor barrier. ■More uniform temperature distribution throughout the wall ensures moisture control. ■Eliminates energy losses associated with thermal-bridging cavity insulation. ■Eliminates concerns over UV exposure as compared to conventional rainscreen components. ■Eliminates the potential for compromising the Air, Vapor Barrier (AVB) and allows for visual inspection and testing of the AVB. ■Results in quicker ROI. Kingspan KarrierPanel™Wall System Direction of heat flowSteel-framed, Built-up Wall System Direction of heat flow 8 Path to NetZero™ Kingspan’s long-term mission will see all our facilities achieve NetZero energy consumption by 2020. NetZero Energy buildings, in the simplest terms, produce as much energy as they consume. Our insulated metal panels are a cost effective step to this high performance goal, offering a building envelope with functionality and design possibility. Our Path to NetZero™app is a unique tool for the building industry that simulates the process of achieving high performance and NetZero energy buildings. Results indicate estimated energy cost savings, CO2, ROI and contributions to LEED®points gained by using Kingspan Insulated Panels. Building professionals and owners today share a newfound enthusiasm for building envelope performance. Driving this focus are mandates for green building, a focus on energy efficiency and recognized ROI. EnvelopeFirst™ Kingspan’s EnvelopeFirst™is a design strategy for optimizing a building’s performance and the first step towards NetZero energy. The EnvelopeFirst™approach to design focuses on enclosure performance, including durability, airtightness, and better moisture and thermal control. Testing and field results show that insulated metal panels (IMPs) contribute to ROI and energy efficiency. Start with the… LEED®Credits Kingspan is committed to supporting green rating systems such as LEED®and Green Globes. Specification of effective systems and materials is key to achieving these certifications. With this in mind, Kingspan provides a LEED®credits guide to assist the building team on how IMPs contribute to overall building performance and ratings criteria. Visit www.kingspanpanels.us/sustainability/leedinformation to download Kingspan’s LEED®statement for project submittals. Sustainability Energy & Atmosphere Materials & Resources Innovation In Design Indoor Environmental Quality Sustainable Sites 9 Goal of an EPD An EPD’s goal is transparency. Knowing what’s in the product you chose and its environmental impact. An important aspect of an EPD is to provide the basis of a fair comparison of products and services by its environmental performance. EPDs can reflect the continuous environmental improvement of products and services over time and are able to communicate and add up relevant environmental information along a product’s supply chain. UL Certified To add credibility to our findings, we engaged UL Environment to verify the results of our EPD. UL has been impartially assessing products since 1894 for safety and viability and have conducted numerous environmental evaluations. UL certified EPDs are based on ISO compliant standards. Our EPD indicates that raw materials are the dominant impact across our products life cycle, therefore we are consciously working with our suppliers to improve this. This data confirms our company policy of utilizing more recycled and less virgin resources whenever possible. To learn about our sustainability journey and download the EPD or App, visit: www.pathtonetzero.com EPD (Environmental Product Declaration) Kingspan Insulated Panels North America, has been awarded the first of its kind UL certified ISO compliant Environmental Product Declaration (EPD). The EPD describes environmental manufacturing footprints from cradle to grave based on an ISO compliant Life Cycle Assessment (LCA). What is an EPD An EPD is a third party verified, internationally recognized disclosure of a product’s environmental impact, from cradle to grave based on an ISO compliant Life Cycle Assessment (LCA). Kingspan’s LCA calculates the environmental footprint at each stage of the supply chain, manufacturing processes, product use and end of life. All the significant environmental impacts associated with the product, including the impact on water, air, land and climate change are reported based on ISO LCA standards. Testing and Services 10 Performance Requirements and Product Listings: Kingspan insulated panels meet specific building envelope performance criteria and requirements stipulated by US and Canadian building codes. Panels are tested in accordance with UL, ULC, FM and ASTM approval standards, testing methods and procedures. Kingspan insulated panels are listed by FM Global and Warnock Hersey. Test Procedure Results Fire FM-4880 Passed: Class 1 Fire Rating of Insulated Wall or Wall and Roof / Ceiling Panels, Interior Finish Materials or Coatings, and Exterior Wall Systems ASTM E84 Flame spread <25, smoke developed <450 CAN/ULC-S101 Fire endurance tests: 10 min and 15 min stayed in place CAN/ULC-S102 Flame spread: 20, Smoke developed: 350 for panel with facings CAN/ULC-S127 Flame spread <500 for foam core CAN/ULC-S134 Passed: Standard method of test for fire of exterior wall assemblies ULC/ORD-C376 Passed: Fire growth of foamed plastic insulated building panels in a full scale room configuration NFPA 259 Tested for potential heat of building materials NFPA 268 Passed: Standard test method for determining ignitability of exterior wall assemblies using a radiant heat energy source NFPA 285 Passed: Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components. Structural FM-4881 Passed: Class +110/-154 Zone H Class +100/-140 Zone HM – LM ASTM E72 Vacuum chamber tested. Panel load / span and deflection tables are available Thermal Performance ASTM C518 R-value per inch = 7.5 h .ft2.°F/Btu.in Air Infiltration ASTM E283 0.003 CFM/ft 2 of Panel Area at 6.24 psf Water ASTM E331 No uncontrolled water penetration at 20 psf differential pressure AAMA 501.1 Dynamic water pressure testing – no sign of water leakage at 15 psf Fatigue Tests Cyclic test to positive and negative The panels exceeded 2 million alternate cycles wind loading to ± L/180 deflection without failure or damage Bond Strength ASTM D1623 Panels tested for tensile bond strength of metal to foam Sample placed in an autoclave device and pressurized to 2 PSI at 212 °F for 21/2 hours No skin delamination with direct pull off pressure up to 1188 psf The above tests were conducted on various Kingspan products, and not all products may comply with the tests shown. If you have any questions on a specific product and/or test, please ask a representative of Kingspan Technical Services. Kingspan does not assure compliance with any plans or specifications and it remains the responsibility of the customer to confirm compliance of the product with applicable local, state and national codes and other laws or regulations. Kingspan Service and Support 11 Sales Team Our regionally based sales team can provide assistance on any project from the design stage through to site installation. Find your local sales rep on our website. Canada - www.kingspanpanels.ca/findasalesrep USA - www.kingspanpanels.us/findasalesrep Email us: Technical and Energy Services: technicalservice@kingspanpanels.com Installation: installation@kingspanpanels.com Marketing: marketingdept@kingspanpanels.com Samples: samplesdept@kingspanpanels.com Follow Kingspan on: Langley, BC Modesto, CA Caledon, ON Columbus, OH Deland, FL Technical Service Kingspan provides a comprehensive technical advisory service to assist architects, engineers, specifiers and installation contractors with building design, product application and site work installation training and challenges. Energy Service Kingspan offers a performance energy modeling service on select projects to help design teams understand scenarios contributing to optimizing the energy efficiency of insulated metal panel assemblies based on meeting or exceeding ASHRAE 90.1 requirements. Customer Service Our dedicated team provides focused customer service for all pre and post-order administration, delivery scheduling, and installer support, ensuring a seamless coordinated customer experience. Marketing Support Our marketing team aims to provide a fast turnaround on standard sample and literature requests, eliminating delays with planning and client approval of material, so that your project begins on time. Additional marketing support is provided through the use of project case studies. Field Service Support Kingspan’s Field Service Engineering Team offer customers free contractor training on the installation of new and existing products, site inspection services as well as advice on mechanical handling solutions. KarrierPanel™Projects 12 13 Construction Details KarrierPanel™with Metal 14 Base at Overhang – Horizontal IMP Vertical Rainscreen Single skin panel (installed vertically) Hat channel – as required Set hat channel in butyl sealant at fastener locations Continuous butyl sealant Continuous butyl sealant both sides of trim 1/4” – 14 hex head fasteners with washer Base channel set in sealant (not by Kingspan) Fastener to concrete (not by Kingspan) Vertical supports (not by Kingspan) Single skin panel base flashing Construction Details KarrierPanel™with Metal 15 Intermediate Support – Horizontal IMP Vertical Rainscreen 1/4” – 14 hex head fasteners with washer Single skin panel (installed vertically) Continuous KarrierRail™(KarrierRail™ available in 1”, 2” & 3” faces) Expansion fastener as required Set KarrierRail™in butyl sealant at fastener locations Vertical support at 16” O.C. (not by Kingspan) 1” Continuous butyl sealant Continuous butyl sealant (optional) Male joint Wall panel installation direction Female joint Construction Details KarrierPanel™with Metal 16 Parapet Detail – Horizontal IMP Vertical Rainscreen FIP insulation – as required Single skin panel parapet assembly Continuous butyl sealant Fastener to parapet backer (not by Kingspan) Membrane roof and parapet backer (not by Kingspan) Parapet blocking (not by Kingspan) Wrap membrane over panel face (not by Kingspan) Set hat channel in butyl sealant at fastener locations Single skin panel (installed vertically) Hat channel – as required 1/4” – 14 hex head fasteners with washer Construction Details KarrierPanel™with Metal 17 Base Detail - Vertical IMP Horizontal Rainscreen Single skin panel (installed horizontally) Expansion fastener – as required 1/4” – 14 hex head fasteners with washer Continuous butyl sealant both sides of trim with marriage bead to vertical panel joint Set KarrierRail™in butyl sealant at fastener locations Continuous KarrierRail™(KarrierRail™available in 1”, 2” & 3” faces) Single skin panel continuous starter / flashing Single skin panel base flashing Continuous butyl sealant Base angle with min. 3” vert. leg for panel attachment set in sealant (not by kingspan) Construction Details KarrierPanel™with Metal 18 Intermediate Support – Vertical IMP Horizontal Rainscreen 1/4” – 14 hex head fasteners with washer Horizontal support (not by Kingspan) Expansion fastener as required Continuous butyl sealant (optional) Continuous KarrierRail™(KarrierRail™ available in 1”, 2” & 3” faces) Single skin panel (installed horizontally) Set KarrierRail™in butyl sealant at fastener locations Continuous butyl sealant Wall panel installation direction 1” Male joint Female joint Construction Details KarrierPanel™with Metal 19 Low Eave Detail – Vertical IMP Horizontal Rainscreen Expansion fastener – as required FIP insulation – as required Refer to 900/1000 series roof panel details for additional information 1/4” – 14 hex head fasteners with washer Continuous butyl sealant with marriage bead to vertical panel joint Eave strut (not by Kingspan) Continuous KarrierRail™(KarrierRail™available in 1”, 2” & 3” faces) Single skin panel (installed horizontally) Construction Details KarrierPanel™with Brick 20 Base Detail – Horizontal IMP 1/4” – 14 through fasteners with 1 1/8” bonded washer (as required for wind load) Vertical metal stud wall (not by Kingspan) Face brick (not by Kingspan) Brick Air gapStud wall Panel thickness Set panel in continuous butyl sealant Waterproofing membrane below grade (not by Kingspan) Flexible membrane flashing (not by Kingspan) Masonry drainage and venting (not by Kingspan) Mortar net (not by Kingspan) Brick tie – HB wing nut with pintle (spacing to be determined by the engineer of record) Construction Details KarrierPanel™with Brick 21 Engaged Panel Detail – Horizontal IMP 1/4” – 14 hex head fasteners without washer 12 Ga. stainless steel hidden fastener clip (1 per panel, per support) set clip in butyl sealant Face brick (not by Kingspan) Brick Air gap Stud wall Panel thickness Continuous butyl sealant at interior panel joint Continuous butyl sealant at exterior panel joint Vertical metal stud (not by Kingspan) Brick tie – HB wing nut with pintle (spacing to be determined by the engineer of record) Brick tie – HB wing nut with pintle (spacing to be determined by the engineer of record) Construction Details KarrierPanel™with Brick 22 Framed Opening – Horizontal IMP 1/4” – 14 pancake through fasteners with 1 1/8” bonded washer (as required for wind load) Face brick (not by Kingspan) Masonry drainage and venting (not by Kingspan) Shelf angle (not by Kingspan) Metal flashing with drip edge set in sealant (by mason) Backer rod and sealant (not by Kingspan) Window system (not by Kingspan) Self-adhering vapor barrier at window rough opening (not by Kingspan) Mortar net (not by Kingspan) Vertical metal stud wall (not by kingspan) Membrane termination bar, fasteners and sealant (by mason) Set panel in continuous butyl sealant Self-adhering membrane with up turned ends to form end dams (by mason) Brick tie – HB wing nut with pintle (spacing to be determined by the engineer of record) Construction Details KarrierPanel™with Brick 23 Framed Opening – Horizontal IMP Face brick (not by Kingspan) 8” hollow concrete block (not by Kingspan) Slip sheet to protect panels (not by Kingspan) Set panel in continuous butyl sealant Self-adhering vapor barrier (not by Kingspan) Wrap roof membrane over panel face (not by Kingspan) Masonry fastener (as required for wind load) (not by Kingspan) Parapet cap and metal flashing cap, sealant and weather tightness (not by Kingspan) Brick tie – HB wing nut with pintle to masonry (spacing to be determined by the engineer of record) 06/2014 Kingspan USA Kingspan Canada Deland, FL : 386-626-6789 Caledon, ON : 905-951-5600 Modesto, CA : 209-531-9091 Langley, BC : 604-607-1101 www.kingspanpanels.us www.kingspanpanels.ca For the product offering in other markets please contact your local sales representative or visit www.kingspanpanels.com Care has been taken to ensure that the contents of this publication are accurate, but Kingspan Limited and its subsidiary companies do not accept responsibility for errors or for information that is found to be misleading. Suggestions for, or description of, the end use or application of products or methods of working are for information only and Kingspan Limited and its subsidiaries accept no liability in respect thereof. Follow Kingspan on: REVISION: 04/26/13 Henry Company 999 N. Sepulveda, Ste 800, El Segundo CA 90245-2754 Technical Services- Phone (800) 486-1278 – Email: techservices@henry.com www.henry.com TECHNICAL DATA SHEET Blueskin SA Self-Adhesive Air/Vapor Barrier Membrane Typical Physical Properties -Color -Thickness -Application Temp -Service Temp -Elongation (ASTM D412-modified) -Tensile Strength (Membrane) (ASTM D412- modified) -Tensile Strength (Film) (ASTM D882) -Minimum Puncture Resistance – Membrane (ASTM E154) -Watertightness (CAN/CGSB-37.58-M86) -Nail Sealability (ASTM D1970) Blue 40 mils (1.0 mm) 41ºF minimum Minus 40°F to 158°F 200% minimum 500 psi minimum 5000 psi minimum 40 lbf. Pass Pass -Low Temperature Flexibility @ -22°F (CGSB 37-GP-56M) -Water Vapor Transmission (ASTM E96 water method) (ASTM E96 desiccant method) -Lap Peel Strength @ 39°F (ASTM D903 180° bend) -Water Absorption (ASTM D570) -Air Leakage @ 75 Pa (ASTM E2178) -Air Leakage After 3000 Pa Test (ASTM E330-90) -Assembly Air Leakage @ 75 Pa (ASTM E2357) -Crack Cycling (ASTM C836) Pass 0.86 perms (49 ng/Pa.s.m2) 0.03 perms (2 ng/Pa.s.m²) 25.0 lbf/in (> 4378.4 N/m) 0.1% 0.0001 cfm/ft2 (0.0005 L/s.m.²) No change 0.001 cfm/ft2 (0.005 L/s.m.²) Pass Packaging -Roll length -Roll width -Top Surface -Bottom Surface 75 ft. 48”, 36”, 18”, 12”, 9”, 6”, 4” Blue Film Siliconized Release Film -Gross Coverage (Net Coverage*) 36” 18” *Based on 2” laps 225 ft2 (212 ft2) 112.5 ft2 (100 ft2) (Side and end laps) Description Blueskin SA is a self-adhering membrane consisting of an SBS rubberized asphalt compound, which is integrally laminated to a blue engineered thermoplastic film. The membrane is specifically designed to be self-adhered to a prepared substrate, providing an air/vapor/water barrier in full wall applications or as penetration/flashing membrane with other air barrier systems. Blueskin SA, in assemblies with primer and BES Sealant meet ASTM E-2357 – reference guide specification for details. Features • SBS modified membrane, flexible at low temperatures • Impermeable to air, moisture vapor and water • Assemblies of Blueskin SA, primer and sealant meet ASTM E-2357 air barrier performance standard. • Excellent adhesion to prepared substrates of concrete, concrete block, primed steel, aluminum mill finish, anodized aluminum, galvanized metal, gypsum board and plywood • Compatible with Henry Air-Bloc liquid air barrier membranes • Membrane is self-gasketing when penetrated and under compression with self-tapping screws REVISION: 04/26/13 Henry Company 999 N. Sepulveda, Ste 800, El Segundo CA 90245-2754 Technical Services- Phone (800) 486-1278 – Email: techservices@henry.com www.henry.com Blueskin SA Self-Adhesive Air/Vapor Barrier Membrane Storage Store rolls on end, on original pallets or elevated platform. Protect from weather or store in an enclosed area not subject to heat over 120°F. Limitations Not designed for permanent exposure to weather - protect as soon as possible, however can be exposed up to 30 days if necessary to accommodate construction scheduling. Not to be used in direct contact with flexible PVC/vinyl membranes or gaskets. Uses Blueskin SA is designed for use as a self-adhered sheet air, vapor and rain barrier. Its principal application is on walls of either masonry, concrete or gypsum board. It can also be used as a transition sheet in conjunction with Henry Liquid Membranes where greater movement is anticipated, due to its high strength. Blueskin SA is also used for tying into metal on curtain walls, windows and doorframes. Surface Preparation Acceptable substrates are precast concrete, cast-in place concrete, concrete block, primed steel, aluminum mill finish, anodized aluminum, galvanized metal, gypsum board including Dens Glass Gold. All surfaces to receive Blueskin SA must be clean of oil, dust and excess mortar. Strike masonry joints flush. Concrete surfaces must be smooth and without large voids, spalled areas or sharp protrusions. Concrete must be cured a minimum of 14 days and must be dry before Blueskin SA is applied. Where curing compounds are used, they must be clear resin based, without oil, wax or pigments. All surfaces to receive Blueskin SA require an application of Blueskin Adhesive or Spray Prep, applied by lambs wool roller, brush or spray at the rate of 85 to 250 ft2/gallon depending on porosity and texture of surface and allowed to dry for 30 minutes before Blueskin SA is applied. Ensure that all surfaces receive Blueskin SA in the same day. Alternatively, apply Aquatac by roller at a rate up to 500 ft2/gallon. Allow to dry to a tacky film. Application Refer to Blueskin SA Guide Specification for detailed application information. Blueskin SA must be lapped a minimum of 2” on both sides and end laps. Position membrane for alignment; remove protective film and press firmly in place. When membrane is entirely in place, roll membrane including seams with a counter top roller to ensure full contact. When using membrane with brick ties, position membrane, press in place and cut for ties or projections. Seal around any openings and at leading edge at the end of the days work with Henry #925 BES Sealant, Polybitume, Air-Bloc 21, or Air-Bloc 21 FR. Membrane applied to the underside of the substrate (i.e. ceilings) requires mechanical fastening through treated wood or galvanized metal strapping, or have insulation mechanically fastened. Fastening must take place immediately after installation of membrane. Space strapping on 18” centers, running perpendicular to the side laps. Detail work must be carefully carried out to ensure continuous air tightness of the membrane. It is recommended that mechanical attachment be made to all window and doorframes, or a properly designed sealant joint be provided. Insulation Application over Membrane Insulation Clips: Insulation clips should be mechanically fastened through the membrane into the substrate with a self-tapping screw. Apply number of insulation clips as recommended by the insulation manufacturer. Insulation Adhesive: Henry Air-Bloc 21 –where permitted by local VOC regulations - should be applied to insulation boards in a serpentine pattern to restrict movement of air behind the insulation. Alternatively, a full coat notched trowel application of Henry Air- Bloc 21 may be applied to the back of the board. Press insulation firmly in place. REVISION: 04/26/13 Henry Company 999 N. Sepulveda, Ste 800, El Segundo CA 90245-2754 Technical Services- Phone (800) 486-1278 – Email: techservices@henry.com www.henry.com Blueskin SA Self-Adhesive Air/Vapor Barrier Membrane Limited Warranty We, the manufacturer, warranty only that this product is free of defects, since many factors which affect the results obtained from this product - such as weather, workmanship, equipment utilized and prior condition of the substrate - are all beyond our control. We will replace at no charge any product proved to be defective within 12 months of purchase, provided it has been applied in accordance with our written directions for uses we recommended as suitable for this product. Proof of purchase must be provided. DISCLAIMER OF WARRANTIES: The Limited Warranty is IN LIEU OF any other warranties express or implied including but not limited to any implied warranty of MERCHANTABILITY or fitness for a particular purpose, and we, the manufacturer, shall have no further liability of any kind including liability for consequential or incidental damages resulting from any defects or any delays caused by replacement or otherwise. STATEMENT OF RESPONSIBILITY The technical and application information herein is based on the present state of our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be made as to a product’s suitability for a particular use or application and no warranty as to its accuracy, reliability or completeness either expressed or implied is given other than those required by law. The user is responsible for checking the suitability of products for their intended use. Henry Company data sheets are updated on a regular basis; it is the user’s responsibility to obtain and to confirm the most recent version. Information contained in this data sheet may change without notice. Henry Company, 999 N. Sepulveda, Ste. 800 El Segundo CA 90245 REV: 04/24/14 Tel: 800-486-1278 Email: techservices@henry.com www.henry.com TECHNICAL DATA SHEET FOILSKIN Self-Adhesive Weather Barrier Membrane Physical Properties -Color -Thickness -Application Temp -Service Temp -Elongation (ASTM D412-modified) -Tensile Strength Membrane (ASTM D412- modified) -Tensile Strength (Foil) (ASTM C1136) Mold Resistance (ASTM C665) Aluminum 40 mils (1.0 mm) Minimum 20F (-7°C) Minus -40F to 140F 40% minimum 900 psi (6.2 mPa) 2812 psi (19.4 mPa) 1875 psi (12.9 mPa) No growth -Minimum Puncture Resistance – Membrane (ASTM E154) -Low Temperature Flexibility @ -22F (CGSB 37-GP-56M) -Water Vapor Permeance (ASTM E96) -Lap Peel Strength @ 40F (ASTM D903 180 bend) 40 lbf (178 N) Pass 2.8 ng/Pa.s.m² (0.05 perms) (15 lbs/ inch) 2600 N/m width Packaging -Thickness -Roll length -Roll width -Gross Coverage 40 mils 33.3’ 36” 100 sq. ft. -Top Surface -Bottom Surface Foil Scrim Siliconized Release Paper Description FOILSKIN® is a self-adhering membrane consisting of an SBS rubberized asphalt compound, integrally laminated to a glass scrim reinforced aluminum foil. The membrane is specifically designed to be self-adhered to a prepared substrate, providing a weather barrier. Features  SBS modified membrane, flexible at low temperatures  Impermeable to air, moisture vapor and water  No flame or adhesive required for installation  Thickness controlled at point of manufacture  Excellent adhesion to prepared insulation substrates  Membrane is self-sealing when penetrated with self-tapping screws  Self-adhesive membrane bond strengthens over time  Does not promote mould growth  Ultra-violet light resistant Uses FOILSKIN® is designed for use as a transition membrane with Air-Bloc 33 Air Barrier System. See Air-Bloc 33 Guide Specification. Storage Store FOILSKIN® rolls on end, on original pallets or elevated platform. Protect unused portion of membrane by storing in original box to maintain self-adhesive quality. Protect from weather elements or store in an enclosed area not subject to heat over 120F. Double stacked pallets are not recommended. If double stacking is necessary, use a plywood sheet to distribute the load. Henry Company, 999 N. Sepulveda, Ste. 800 El Segundo CA 90245 REV: 04/24/14 Tel: 800-486-1278 Email: techservices@henry.com www.henry.com FOILSKIN® Self-Adhesive Weather Barrier Membrane Limitations FOILSKIN® is not to be used in direct contact with flexible/highly plasticized PVC/vinyl membranes or gaskets. Some sealants may discolor if in contact with the asphalt compound or may soften the asphalt compound. Contact sealant manufacturer for more information. Surface Preparation Acceptable substrates are precast concrete, cast-in place concrete, concrete block, primed steel, aluminum mill finish, anodized aluminum, galvanized metal, gypsum board including Dens Glass Gold. All surfaces to receive Foilskin must be clean of oil, dust and excess mortar. Strike masonry joints flush. Concrete surfaces must be smooth and without large voids, spalled areas or sharp protrusions. Concrete must be cured a minimum of 14 days and must be dry before Foilskin® is applied. Where curing compounds are used, they must be clear resin based, without oil, wax or pigments. All surfaces to receive Foilskin® require an application of Blueskin® Primer applied by lambs wool roller or brush at the rate of 85 to 250 sq. ft./gallon depending on porosity and texture of surface and allowed to dry for 30 minutes before Foilskin® is applied. Ensure that all surfaces receive Foilskin® in the same day. Alternatively, apply Aquatac™ Primer by roller at a rate up to 500 sq. ft/gallon. Allow to dry to a tacky film. Application Refer to Air-Bloc 33 Guide Specification and details for further application information. Foilskin® must be lapped a minimum of 2” on both sides and end laps. Position membrane for alignment, remove protective film and press firmly in place. When membrane is entirely in place, roll membrane including seams with a counter top roller to ensure full contact. When using membrane with brick ties, position membrane, press in place and cut for ties or projections. Seal around any openings and at leading edge at the end of the days work with Air-Bloc 33. Membrane applied to the underside of the substrate (i.e. ceilings) requires mechanical fastening through treated wood, galvanized metal strapping, or have insulation mechanically fastened. Fastening must take place immediately after installation of membrane. Space strapping on 18” centers, running perpendicular to the side laps. Detail work must be carefully carried out to ensure continuous air tightness of the membrane. It is recommended that mechanical attachment be made to all window and doorframes, or a properly designed sealant joint be provided. Caution FOILSKIN® is highly reflective to sunlight. It is strongly recommended to use sunglasses to prevent eye damage when working with the membrane. Limited Warranty We, the manufacturer, warranty only that this product is free of defects, since many factors which affect the results obtaine d from this product - such as weather, workmanship, equipment utilized and prior condition of the substrate - are all beyond our control. We will replace at no charge any product proved to be defective within 12 months of purchase, provided it has been applied in accordance with our written directions for uses we recommended as suitable for this product. Proof of purchase must be provided. DISCLAIMER OF WARRANTIES: The Limited Warranty is IN LIEU OF any other warranties express or implied including but not limited to any implied warranty of MERCHANTABILITY or fitness for a particular purpose, and we, the manufacturer, shall have no further liability of any kind including liability for consequential or incidental damages resulting from any defects or any delays caused by replacement or otherwise. <> Northshore, please clarify FIP insulation by Northshore Vertical support is responsibility of Northshore where panel ends do not land on stud. NBBJ, please confirm 'Vertical Support' must conform to 074219 2.5 A Misc Metal Subframing NBBJ: CONFIRMED, DETAIL BELOW OR DETAIL 3/KIP601 AS APPROPRIATE TO SUPPORT PANEL EDGES & TRANSFER LOADS PER MANUFACTURER'S RECOMMENDATIONS. 36"KS36KPEXTERIOR FACEINTERIOR FACE3"KIP 101SWEDISH EDMONDSAMBULATORY CARE CENTEREDMONDS, WASHINGTONa. Non-exposed sealant shall be field applied gun grade non-skinning butyl.b. Exposed sealant shall be field applied gun grade urethane or silicone sealant. (Not By KINGSPAN INSULATED PANELS)c. KINGSPAN INSULATED PANELS is not responsible for field installed vapor seal at joints and junctures.d. KINGSPAN INSULATED PANELS is not responsible for vapor leaks caused by penetration throughthe panels.a. All trim shall be fabricated from G90 or AZ50 in gauge and finish to match panel face.b. All trim is fastened at 12" o.c. unless otherwise noted in the details.a.Holes in panels for other trades to be cut, sealed and flashed by the trade concerned unless otherwise noted on these drawings.b. Openings which would reduce the structural strength of the panel are to be adequately reinforced byothers.a.The face of all steel must be free of bolt and rivet heads, built up welds or other obstruction which might interfere with bearing of panels on girts or purlins.b. Girts for support of panels must extend to outer extremities of elevations and across face of columnsto which panels are applied.c. All panels supports are to be true and plumb prior to erectingpanels. Recommended wall tolerance is 14" in any 20' direction. Recommend roof tolerance is 0" outward, 12" inward from plane.The following specifications appear on shop drawings prepared by KINGSPAN INSULATED PANELS.They are intended to be a guide for minimum acceptable installation procedures and to indicate thequantity, size and materials specification of products furnished by KINGSPAN INSULATED PANELS, forthe described project. They should not be used to replace or supplant specifications or notes on structuraldrawings. Materials shown on these drawings and specifications have been approved by KINGSPANINSULATED PANELS for the purpose shown.Exercise care to maintain uniform side joints on all panels at each elevation.GENERAL NOTES:SEALANTS:TRIM:WORK OF OTHER TRADES:SUPPORTING STEEL AND GIRT SYSTEMS:MODULE RETENTION:FIELD-CUT PANELS:a.Field cutting shall be performed in accordance with current Kingspan installation guides.b.Field-cut panels where required at openings as shown on drawings. Cut edges are to be covered with trim.c.Field-cut panels to slope at endwalls.d.Some field cutting may be required.TOUCH UP:Use matching color touch up on material where damage consists of small chips, abrasions and field cutedges. Touch up paint may be obtained by contacting Kingspan customer service. For larger area paintrepairs, consult the Kingspan Maintenance Manual for instructions. Each panel shall be covered until justprior to erection. Care should be taken not to allow panel facings to come in contact with dirt, oil, grease,standing water or any other material which could stain exposed surfaces. Carefully follow storage andhandling instructions included with shipping documents.ON-SITE STORAGE:Panels and accessories are to be adequately protected from traffic and weather to ensure againstphysical damage or discoloration. Each panel shall be covered until just prior to erection. Care should betaken not to allow panel facings to come in contact with dirt, oil, grease, standing water or any othermaterial which could stain exposed surfaces. Carefully follow storage and handling instructions includedwith shipping documents.SHEET INDEXPAGE #DESCRIPTIONGENERAL INFORMATION, CALCULATIONSFLOOR PLANSKIP 101-102KIP 201-202LEGEND:ABBREVIATIONS:NOT ALL ABBREVIATIONS MAY BE USED ON THIS PROJECTAFF B.O.P.BLDG. CBCCMUF.F.F.O.GA.GALV.HORIZ.IBCNTS O/O PPH SIM.T.O.T.O.P.T.O.S.TYP.UBCUREW/ W/OWSHRSS ABOVE FINISH FLOORBOTTOM OF PANELBUILDINGCALIFORNIA BUILDING CODECONCRETE MASONRY UNITFINISH FLOORFRAMED OPENINGGAUGEGALVANIZEDHORIZONTALINTERNATIONAL BUILDING CODENOT TO SCALEON CENTEROUT TO OUTPHILIPS PANHEADSIMILARTOP OFTOP OF PANELTOP OF STEELTYPICALUNIFORM BUILDING CODEURETHANEWITHWITH OUTWASHERSTANDING SEAMO.C. OR O/CDISCLAIMER:CUSTOMER REVIEW CHECKLIST:Panel Information:ƑPanel type and thicknessƑGauge and color of the exterior/interior skinsƑ,IFRORULV³7REHGHWHUPLQHG´SOHDVHPDUNXSWKHGUDZLQJVZLWKWKHFKRVHQFRORUDQGFRQWDFWyour project coordinator to confirm the color selectionFloor Plans:ƑGrid lines on the plans are correctƑDimensions shown on the floor plan are correct with the latest structural/steel drawingsƑFloor plans are representative of where Kingspan materials are to be providedƑIf there are panel areas missing or not clearly shown, please mark up the drawings andcontact your project coordinator to reviewRoof Plans: (If applicable)ƑRoof dimensions are accurateƑRoof panel lengths are correct with the latest structural/steel drawingsƑEndlaps (if present) are lined up with a roof purlinƑOverhangs (if present) are properly shownƑCanopy areas (if present) are properly shownƑIf there are missing panels, overlaps needed that are not shown, or wrong dimensionsplease mark up the drawings and contact your project coordinatorElevations:ƑElevation tags show the correct location of the bottom of panel and top of panel/parapet/steelƑFramed opening sizes, locations, and quantities are correctƑWall length dimensions are correct and match the floor planƑWall panel lengths are correct at each elevation shownƑDetail called out corresponds to the correct condition at that locationƑQuantity and length of panels called out in panel lists correspond with that shown for each elevationƑIf multiple panel types, verify that the proper panel types are being used in the proper locationƑIf panel areas are missing or not clearly shown, please identify on the drawings and contact your project coordinator to reviewDetails:Please review each detail shown thoroughly, with special attention to the following:ƑBase condition(s) correct (flush mount or overhung?)ƑSlab edge shown is correct, matches concrete condition (squared off or keyway?)ƑWindow details and flashings drawn correctlyƑOverhead door details and flashings drawn correctlyƑTrims necessary for proper installation shown in details (special attention should be paid to those PDUNHG³1RWE\.LQJVSDQ´ ƑLocation and type of structural members shown in details reflect actual structural members present QRWHSOHDVHLQGLFDWHRQWKHGUDZLQJVLIWKHUHDUHDQ\ORFDWLRQVXWLOL]LQJVWHHOWKLFNHUWKDQó´VRWKDWproper fasteners may be designated)ƑIf any detail conditions are omitted or are incorrect, please clearly identify on the drawingsTrims:ƑTrims to be provided as shownƑGauge and color of each trim piece is correctly identifiedƑShapes and dimensions of each trim are correctƑIf a different trim shape/dimension or color is desired, please mark up the drawings as neededAFTER COMPLETING THIS CHECKLIST, PLEASE CHECK THE APPROPRIATE BOX LOCATED IN7+(³)25$33529$/´6(&7,212)7+(7,7/(%/2&.7+(16,*1$1'5(78517+(DRAWINGS TO YOUR KINGSPAN PROJECT COORDINATOR.This checklist is provided as a guide when reviewing Kingspan shop drawings. Please take amoment to verify that the following information presented in these drawings is correct:Wall Sections:ƑWall construction/materials/panel thicknesses are correctƑElevations of support members are correctƑWall panel lengths are correctKIP 401-407WALL ELEVATIONSKIP 601-604DETAILSA2GRID LINE DESTINATIONELEVATIONDETAIL DESTINATIONELEVATION VIEW2GRID LINE DESTINATION2CROSS SECTION2DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEET AFGABOVE FINISH GRADEB.F.F.BELOW FINISH FLOORƑAPPROVED AS SUBMITTEDƑAPPROVED AS NOTEDƑREVISE / RESUBMITThese Approval Drawings are submitted for the above referenced project. Please review, sign, and return the Drawings marked either:"Approved as Submitted" (if there are no corrections),"Approved as noted" (with correction(s) clearly noted on the returned Drawing set), or"Revise / Resubmit" (with correction(s) clearly noted on the returned Drawing set).All dimensions, details and trims require approval/verification.All "clouded areas" must be reviewed and addressed to the satisfaction of Kingspan, before materials will be released for Fabrication and/orProduction Drawings will be issued.Approval of the Kingspan Drawings and panel analysis indicates that Kingspan has correctly interpreted the project requirements, and thedesigns thereof. This approval constitutes the acceptance of Kingspan dimensions, layouts, materials, and designs unless clearly notedotherwise.Kingspan is not responsible for checking the material and/or design compatibility of components that are not supplied by Kingspan.APPROVAL SIGNATURE DATE:PRINTED NAME & COMPANY OF SIGNATURE DATE:THESE DRAWING ARE ISSUED FOR KINGSPAN PRODUCT APPROVAL/VERIFICATION ONLY AND SHOULD NOT BE USED FOR INSTALLATION PURPOSES - "FOR PRODUCTION" DRAWINGS SHALL BE ISSUED AFTER APPROVED DRAWINGS HAVE BEEN RECIEVED AND PROCESSEDKIP 701-702TRIMSCustomer to verify that the provided steel and/or architectural drawings upon which the Panel layoutand designs are based, are correct and accurately reflect the conditions necessary for design of allmaterials supplied by KINGSPAN. Customer must also verify that the project field conditions arerepresentative of the drawings submitted, OR that any and all necessary revised conditions that mayimpact design, have been submitted to and confirmed by KINGSPAN, prior to the release ofKINGSPAN Panel drawings or calculations.KINGSPAN is not responsible or liable for incorrect Panel lengths as a result of changes made aftersigned approved shop drawings are returned.Drawings furnished by KINGSPAN show Panel layouts, wall elevations, and fastening details only;they do not replace structural drawings. It is the project engineers or project architect's responsibilityto determine if allowable Panel and fastener loads meet the project design loads.KINGSPAN is only responsible for showing items that are furnished by KINGSPAN. Referencedimensions shown on these drawings have been taken from steel / architectural drawings providedby the customer, and have not been independently verified by KINGSPAN.Items not included in KINGSPAN material bid package may be shown in the drawings / details forinformational purposes only. KINGSPAN will supply only those items specifically included in theOrder Acknowledgement. It is the customer's (or the authorized agent's) responsibility to verifyKINGSPAN'S scope.Optional engineering seal provided by KINGSPAN on these drawings indicates Panel spans andconnections have been verified and approved for use as drawn. This approval pertains solely to thematerials being supplied by KINGSPAN, and does NOT apply to the structural supports or any othercomponents which may be shown on the drawings (for clarification purposes only). These items mustbe reviewed and approved by the project engineer of record.WALL PANEL CONFIGURATION: 3"36"UrethaneEXTERIOR FACEKS36KPCoverageProfileMaterialTextureGaugeFinishColorCore ThicknessCore MaterialPanel TypeAZ50ShadowlineMP26Stucco EmbossedINTERIOR FACEMP26AZ50Stucco EmbossedShadowlineImperial WhiteImperial WhiteKIP 501SOFFIT PLAN3/31/2015 3:15:27 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details. KIP 102DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:3/31/2015 3:15:29 PM 363'-0"1NMLKJHGFEDCBA2344.85XAYA1'132'-0"14311/16" = 1'-0"LEVEL ONE FLOOR PLAN /23241256KIP 201DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:3/31/2015 3:15:35 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details. 1LKJHGFEDCBA2344.85XAYAX12X10X9X7X6X5X4X7.4X8101/16" = 1'-0"LEVEL TWO FLOOR PLAN /303'-6"132'-0"132324121298741311EW2EW1KIP 202DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:3/31/2015 3:15:36 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details. 1PANELS QUANTITY --GRID LINE 1'1/8" = 1'-0"128'-4" O/O PANEL10482TYPT.O.P.15'-0"LEVEL 10'-0"69'-9" O/O PANEL3TYP2828B.O.P.0'-6"T.O.P.24'-0"143'-3" O/O PANEL16723'-3"23'-3"23'-3"32'-1"32'-1"32'-1"32'-1"3PANELS QUANTITY --GRID LINE A1/8" = 1'-0"114LEVEL 10'-0"B.O.P.0'-6"T.O.P.56'-0"126'-1014" O/O PANEL281025'-512"25'-512"25'-512"25'-512"25'-014"8'-212"15112TYP3TYP2821SIMKIP 401DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:ALL DIMENSIONS AREO/O OF PANELSREQUIRE VERIFICATION--NOT BY KINGSPAN.ALL DIMENSIONS AND PANEL LENGTHSNOTE:22242323@ STOREFRONT252626@ DOOR3/31/2015 3:15:37 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details. 2PANELS QUANTITY --GRID LINE 11/8" = 1'-0"166'-1034" O/O PANEL4LEVEL 10'-0"28B.O.P.0'-6"T.O.P.41'-0"161010931'-734"31'-734"27'-234"25'-512"25'-512"25'-512"3TYP3TYP1076'-434" O/O PANEL281025'-512"25'-534"25'-512"2GRID LINE 1 - CONTINUED1/8" = 1'-0"LEVEL 10'-0"B.O.P.0'-6"T.O.P.56'-0"2TYPKIP 402DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:ALL DIMENSIONS AREO/O OF PANELSREQUIRE VERIFICATION--NOT BY KINGSPAN.ALL DIMENSIONS AND PANEL LENGTHSNOTE:22242323@ STOREFRONT252626@ DOOR3/31/2015 3:15:38 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details. 4PANELS QUANTITY --GRID LINE XA1/8" = 1'-0"4LEVEL 10'-0"B.O.P.0'-6"11233284'-714" O/O PANEL28'-238"T.O.P.41'-0"LEVEL 222'-0"B.O.P.31'-0"T.O.P.56'-0"76'-7" O/O PANEL20'-218"45'-6" O/O PANEL43'-514" O/O PANEL21'-858"21'-858"28'-238"28'-212"2228'-212"28'-238"22'-9"22'-9"28281112132042TYP3TYP212811'-478"SIM5PANELS QUANTITY --ELEVATION 51/8" = 1'-0"4LEVEL 10'-0"B.O.P.0'-6"16103218'-838" O/O PANEL6PANELS QUANTITY --ELEVATION 61/8" = 1'-0"4LEVEL 10'-0"B.O.P.0'-6"10203274'-434" O/O PANELT.O.P.11'-0"T.O.P.11'-0"18'-534"32'-0"23'-11"222TYP2323KIP 403DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:ALL DIMENSIONS AREO/O OF PANELSREQUIRE VERIFICATION--NOT BY KINGSPAN.ALL DIMENSIONS AND PANEL LENGTHSNOTE:22242323@ STOREFRONT252626@ DOOR3/31/2015 3:15:39 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details. 7PANELS QUANTITY --GRID LINE XA1/8" = 1'-0"B.O.P.31'-0"T.O.P.41'-0"145'-012" O/O PANEL21'-714"25'-512"25'-512"25'-512"25'-512"1228421'-714"173TYP8PANELS QUANTITY --GRID LINE X8 - CONNECTOR1/8" = 1'-0"B.O.P.19'-0"PENTHOUSE38'-0"66'-712" O/O PANEL25'-512"25'-512"172815'-812"LEVEL 222'-0"6B.O.P.31'-0"T.O.P.25'-0"312'-5"9PANELS QUANTITY --GRID LINE X7.4 - CONNECTOR1/8" = 1'-0"B.O.P.19'-0"T.O.P.41'-0"97'-10" O/O PANEL25'-512"25'-512"182816'-514"LEVEL 222'-0"6PENTHOUSE38'-0"312'-5"30'-534"6'-11"B.O.P.23'-6"52TYP2TYP3TYP3TYPSIMSIMKIP 404DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:ALL DIMENSIONS AREO/O OF PANELSREQUIRE VERIFICATION--NOT BY KINGSPAN.ALL DIMENSIONS AND PANEL LENGTHSNOTE:22242323@ STOREFRONT252626@ DOOR3/31/2015 3:15:40 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details. 10PANELS QUANTITY --GRID LINE J1/8" = 1'-0"T.O.P.41'-0"108'-1118" O/O PANEL25'-512"25'-512"102832'-658"LEVEL 222'-0"18PENTHOUSE38'-0"525'-512"B.O.P.23'-6"2TYP2TYP3TYP11PANELS QUANTITY --GRID LINE YA1/8" = 1'-0"145'-112" O/O PANEL24'-214"24'-214"102824'-214"LEVEL 222'-0"10524'-214"T.O.P.24'-0"B.O.P.15'-0"165514'-278" O/O PANEL10283224'-214"24'-214"18'-1134"10'-278"26'-812"5'-038"2'-0" O/O PANEL19192TYP3TYP2811PANELS QUANTITY --GRID LINE YA - CONTINUED1/8" = 1'-0"59'-312" O/O PANEL29'-734"1428LEVEL 222'-0"529'-734"T.O.P.24'-0"B.O.P.15'-0"16102852TYP3TYPKIP 405DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:ALL DIMENSIONS AREO/O OF PANELSREQUIRE VERIFICATION--NOT BY KINGSPAN.ALL DIMENSIONS AND PANEL LENGTHSNOTE:22242323@ STOREFRONT252626@ DOOR3/31/2015 3:15:41 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details. 12PANELS QUANTITY --PENTHOUSE1/8" = 1'-0"134LEVEL 10'-0"T.O.P.56'-0"132'-134" O/O PANEL281025'-512"25'-512"30'-9"25'-512"25'-014"8'-212"PENTHOUSE38'-0"2TYP3TYPEW2PANELS QUANTITY --EXHAUST WELL1/8" = 1'-0"164T.O.P.56'-0"59'-212" O/O PANEL281929'-714"29'-714"PENTHOUSE38'-0"EW1PANELS QUANTITY --EXHAUST WELL1/8" = 1'-0"194T.O.P.56'-0"22'-534" O/O PANEL2816PENTHOUSE38'-0"KIP 406DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:ALL DIMENSIONS AREO/O OF PANELSREQUIRE VERIFICATION--NOT BY KINGSPAN.ALL DIMENSIONS AND PANEL LENGTHSNOTE:22242323@ STOREFRONT252626@ DOOR3/31/2015 3:15:43 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details. 13PANELS QUANTITY --CANOPY1/8" = 1'-0"LEVEL 10'-0"250'-1112" O/O PANELLEVEL 222'-0"33'-0"34'-5"28'-5"19'-6"19'-6"19'-6"28152TYP3TYP250'-1112" O/O PANEL13'-814"19'-6"19'-6"19'-6"33'-214"19'-6"19'-6"27'-612"4'-0"B.O.P.13'-0"1031311013PANELS QUANTITY --CANOPY - CONTINUED1/8" = 1'-0"3114'-234"321027SIMSIMKIP 407DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:ALL DIMENSIONS AREO/O OF PANELSREQUIRE VERIFICATION--NOT BY KINGSPAN.ALL DIMENSIONS AND PANEL LENGTHSNOTE:3/31/2015 3:15:44 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details. 4.85XAX12X10X9X7X7.4X8YA1/16" = 1'-0"SOFFIT PLAN 13'-2 " 12'-5 " 11'-8 " 10'-1 1 " 10'-2 " 9'-5" 8'-8" 7'-11 " 7'-2" 6'-5" 5'-8" 4'-11 " 4'-2" 3'-5" 3'-0" 14'-8 " 13'-1 1 " 15'-5 " 16'-2 " 16'-1 1 " 17'-8 " 18'-5 " 19'-2 " 19'-1 1 " 20'-8 " 21'-5 " 22'-2 " 22'-9 " 20'-0 " 10'-9 " 6'-6" 7'-6" 8'-6" 9'-6" 10'-5 " 11'-5 " 13'-4 " 12'-5 " 15'-4 " 14'-4 " 16'-4 " 17'-3 " 17'-9"19'-2"3131323232323218'-3 " 19'-3 " 20'-2 " 21'-2 " 22'-2 " 23'-1 " 24'-1 " 25'-1 " 26'-1 " 27'-0 " 28'-0 " 28'-2 " 27'-1 0 " 27'-5 " 27'-0 " 26'-7 " 26'-2 " 25'-9 " 25'-4 " 24'-1 1 " 24'-6 " 24'-0 " 23'-7 " 24'-6 " 22'-9 " 22'-4 " 21'-1 1 " 21'-6 " 21'-1 " 20'-8 " 20'-3 " 19'-1 0 " 19'-5 " 19'-0 " 18'-7 " 18'-2 " 17'-9 " 17'-4 " 16'-1 1 " 16'-5 "71'-11"247'-0 1/2"313232SIMSIM14'-83 8"KIP 501DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:ALL DIMENSIONS AREO/O OF PANELSREQUIRE VERIFICATION--NOT BY KINGSPAN.ALL DIMENSIONS AND PANEL LENGTHSNOTE:3/31/2015 3:15:45 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details.NBBJ: REQUESTED DETAIL @ CURTAINWALLHEAD NOT PROVIDED. REFERENCE 13 &14/A8.04. CONTINUITY OF WEATHER, AIR &THERMAL BARRIER PAST HEAD SUPPORTINGCHANNEL TO CURTAINWALL HEAD SHALL BEMAINTAINED. GC TO VERIFY & COORDINATE. 27356894SECTION VIEWPANEL JOINT SCALE: N.T.S.PLAN VIEWINTERMEDIATE SUPPORT SCALE: N.T.S.1VERTICAL JOINT PLAN VIEWSCALE: N.T.S.SECTION VIEWBASESCALE: N.T.S.FIELD CUT PANEL AS REQ'D(NOT BY KINGSPAN)CONTINUOUS BUTYL SEALANTAT PANEL JOINTS&217,18286.$55,(5Œ5$,/(1) 14" - 14 x 4" TEK 3FASTENERS w/ WASHERAT EVERY OTHER STUD6(7.$55,(5Œ5$,/,1%87</SEALANT AT FASTENERLOCATIONSFEMALE JOINTMALE JOINT WALL PANEL INSTALLATION DIRECTION VERTICAL SUPPORT(NOT BY KINGSPAN)METAL PANEL(NOT BY KINGSPAN)MP-1 CONTINUOUS MENDINGPLATE w/ POP RIVETS @ 12" O/CATTACHED TO STUD FRAMINGPRIOR TO PANEL INSTALLATIONCONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTFILL GAPS 14" OR LARGERWITH F.I.P. INSULATION(NOT BY KINGSPAN)VERTICAL SUPPORT(NOT BY KINGSPAN)&217,18286.$55,(5Œ5$,/6(7.$55,(5Œ5$,/,1%87</SEALANT AT FASTENERLOCATIONS5" MIN.5" MIN.OPTIONAL FRAMINGTRIPLE STUD(2) 14" - 14 x 4" TEK 3FASTENERS w/o WASHERMETAL PANEL SYSTEM(NOT BY KINGSPAN)&217,1286.$55,(5Œ5$,/SINGLE SKIN PANEL(NOT BY KINGSPAN)(2) 14" - 14 x 4" TEK 3FASTENERS w/ WASHERAT EVERY OTHER STUDVERTICAL SUPPORTAT 16" O.C.(NOT BY KINGSPAN)6(7.$55,(5Œ5$,/,1%87</SEALANT AT FASTENERLOCATIONSMETAL PANEL(NOT BY KINGSPAN)4" DP3 FASTENER@ 12" O.C.BUTYL SEALANTMETAL STUD FRMGBY OTHERSFLEXIBLE FLASHING(NOT BY KINGSPAN)SCALE: N.T.S.SECTION VIEWBASE @ ROOFBUILT UP ROOF(NOT BY KINGSPAN)14" - 14 x 4" TEK 3 FASTENERSw/ WASHER @ 12" O.C.MEMBRANE FLASHING(NOT BY KINGSPAN)CONTINUOUSBUTYL SEALANTSECTION VIEWBASESCALE: N.T.S.METAL PANEL(NOT BY KINGSPAN)BUTYL SEALANTMETAL STUD FRMGBY OTHERSFLEXIBLE FLASHING(NOT BY KINGSPAN)JC-1 "J" CLIP w/1" DP3 @ 12" O.C.w/ SEALANT IN BASEFILL GAPS 14" OR LARGERWITH F.I.P. INSULATION(NOT BY KINGSPAN)SCALE: N.T.S.PLAN VIEWPANEL @ EXPANSION JOINTCT-3 CAP TRIMCONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTMETAL PANEL(NOT BY KINGSPAN)FASTENER(NOT BY KINGSPAN)SUB FRAMING AS REQUIRED(NOT BY KINGSPAN)EXPANSION JOINT(NOT BY KINGSPAN)(2) 14"-14 x 4" TEK 3 w/oWASHER, PER SUPPORTCT-3 CAP TRIMVERTICAL SUPPORT(NOT BY KINGSPAN)CONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTMETAL PANEL(NOT BY KINGSPAN)SUB FRAMING(NOT BY KINGSPAN)EXPANSION JOINT(NOT BY KINGSPAN)CONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTSCALE: N.T.S.PLAN VIEWPANEL @ EXPANSION JOINTSCALE: N.T.S.PLAN VIEWPANEL @ EXPANSION JOINT(2) 14" - 14 x 4" TEK 3FASTENERS w/o WASHERMETAL PANEL(NOT BY KINGSPAN)SUB FRAMING AS REQUIRED(NOT BY KINGSPAN)EXPANSION JOINT(NOT BY KINGSPAN)14" - 14 x 4" TEK 3FASTENERS w/ WASHERAT EVERY OTHER STUD(1) 14" - 14 x 4" TEK 3FASTENERS w/ WASHERAT EVERY OTHER STUD&217,18286.$55,(5Œ5$,/(2) 14" - 14 x 4" TEK 3FASTENERS w/o WASHERPER SUPPORTKIP 601DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:3/31/2015 3:15:46 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details. 111612101415171813SCALE: N.T.S.PLAN VIEWOUTSIDE CORNER SCALE: N.T.S.PLAN VIEWINSIDE CORNER SCALE: N.T.S.PLAN VIEWINSIDE CORNER (2) 14"-14 x 4" TEK 3 w/WASHER, PER SUPPORTOC-7 OUTSIDE TRIMw/ #10 x 34" PPH @ 12" O.C.CONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTMETAL PANEL(NOT BY KINGSPAN)6(7.$55,(5Œ&/,3,1BUTYL SEALANT ATFASTENER LOCATIONS.$55,(5Œ5$,/IC-7 INSIDE CORNER TRIMw/ POP RIVETS @ 12" O.C.(2) 14"-14 x 4" TEK 3 w/oWASHER, PER SUPPORTIC-1 INSIDE CORNER TRIMVERTICAL SUPPORT(NOT BY KINGSPAN)FIELD MITER CUTPANELSCONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTMETAL PANEL(NOT BY KINGSPAN)OC-1 OUTSIDE CORNERw/ POP RIVETS @ 12" O.C.F.I.P. INSULATIONAS REQUIRED(BY OTHERS)SUB FRAMING AS REQUIRED(NOT BY KINGSPAN)OUTSIDE CORNER OUTSIDE CORNER PLAN VIEWSCALE: N.T.S.IC-2 INSIDE CORNER TRIMSCALE: N.T.S.OUTSIDE CORNER PLAN VIEWSCALE: N.T.S.PLAN VIEWSCALE: N.T.S.PLAN VIEWOUTSIDE CORNER SUB FRAMING(NOT BY KINGSPAN)METAL PANEL(NOT BY KINGSPAN)(2) 14"-14 x 4" TEK 3 w/oWASHER, PER SUPPORTCONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTOC-2 OUTSIDE CORNERw/ POP RIVETS @ 12" O.C.KARRIERŒ RAILCONTINUOUS KARRIERŒ RAILBUTYL SEALANTBUTYL SEALANTOC-3 OUTSIDE CORNERw/ POP RIVETS @ 12" O.C.METAL PANEL(NOT BY KINGSPAN)SUB FRAMING(NOT BY KINGSPAN)BUTYL SEALANT(2) 14"-14 x 4" TEK 3 w/oWASHER, PER SUPPORTCONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTIC-3 INSIDE CORNER TRIMSUB FRAMING(NOT BY KINGSPAN)METAL PANEL(NOT BY KINGSPAN)(2) 14"-14 x 4" TEK 3 w/oWASHER, PER SUPPORTCONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTIC-4 INSIDE CORNER TRIMOC-4 OUTSIDE CORNERw/ POP RIVETS @ 12" O.C.KARRIERŒ RAILBUTYL SEALANTMETAL PANEL(NOT BY KINGSPAN)SUB FRAMING AS REQUIRED(NOT BY KINGSPAN)(2) 14"-14 x 4" TEK 3 w/oWASHER, PER SUPPORTOC-5 OUTSIDE CORNERw/ POP RIVETS @ 12" O.C.CONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTIC-5 INSIDE CORNER TRIMBUTYL SEALANTKARRIERŒ RAILOUTSIDE CORNER SCALE: N.T.S.PLAN VIEWSUB FRAMING(NOT BY KINGSPAN)METAL PANEL(NOT BY KINGSPAN)(2) 14"-14 x 4" TEK 3 w/oWASHER, PER SUPPORTCONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTOC-6 OUTSIDE CORNERw/ POP RIVETS @ 12" O.C.IC-6 INSIDE CORNER TRIMw/ #10 x 34" PPH @ 12" O.C.KARRIERŒ RAILBUTYL SEALANTSCALE: N.T.S.PLAN VIEWINSIDE CORNER METAL PANEL(NOT BY KINGSPAN)SUB FRAMING(NOT BY KINGSPAN)(2) 14"-14 x 4" TEK 3 w/oWASHER, PER SUPPORTCONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTIC-8 INSIDE CORNER TRIMKARRIERŒ RAILBUTYL SEALANTOC-8 OUTSIDE CORNERw/ POP RIVETS @ 12" O.C.METAL PANEL(NOT BY KINGSPAN)SUB FRAMING(NOT BY KINGSPAN)OC-9 OUTSIDE CORNERw/ #10 x 34" PPH @ 12" O.C.KARRIERŒ RAILBUTYL SEALANT(2) 14"-14 x 4" TEK 3 w/oWASHER, PER SUPPORTCONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTIC-9 INSIDE CORNER TRIMw/ POP RIVETS @ 12" O.C.KIP 602DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:3/31/2015 3:15:48 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details. 202521192324262722SCALE: N.T.S.PLAN VIEWINSIDE CORNER @ PERP. TO PANEL(2) 14"-14 x 4" TEK 3 w/WASHER, PER SUPPORTCT-3 CAP TRIMCONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTMETAL PANEL(NOT BY KINGSPAN)6(7.$55,(5Œ&/,3,1BUTYL SEALANT ATFASTENER LOCATIONS.$55,(5Œ5$,/BACKER ROD & SEALANT(NOT BY KINGSPAN)(2) 14"-14 x 4" TEK 3 w/WASHER, PER SUPPORTCT-3 CAP TRIMCONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTMETAL PANEL(NOT BY KINGSPAN)6(7.$55,(5Œ5$,/,1BUTYL SEALANT ATFASTENER LOCATIONS.$55,(5Œ&/,3SUB FRAMING & FASTENER(NOT BY KINGSPAN)WINDOW SYSTEM(NOT BY KINGSPAN)EXPOSED SEALANT(NOT BY KINGSPAN)FIELD CUT PANELS AS REQUIREDFLASHING(NOT BY KINGSPAN)PANEL SYSTEM(NOT BY KINGSPAN)CONTINUOUS BUTYL SEALANT14" - 14 x 4" TEK 3 FASTENERSw/ WASHER @ 12" O.C.SUB FRAMING(NOT BY KINGSPAN)NOTE:SEE ARCHITECTURAL DETAILS 1 & 4/A8.04SCALE: N.T.S.PLAN VIEWINSIDE CORNER @ GLAZINGPANEL SYSTEM(NOT BY KINGSPAN)SUB FRAMING AS REQUIRED(NOT BY KINGSPAN)(2) 14"-14 x 4" TEK 3 w/oWASHER, PER SUPPORTCONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTIC-10 INSIDE CORNER TRIMKARRIERŒ RAILBUTYL SEALANTOC-10 OUTSIDE CORNERw/ POP RIVETS @ 12" O.C.(2) 4" DP3 PER SUPPORTSCALE: N.T.S.PLAN VIEWJAMBSCALE: N.T.S.SECTION VIEWHEADSCALE: N.T.S.SECTION VIEWSILLSCALE: N.T.S.PLAN VIEWDOOR JAMBSCALE: N.T.S.SECTION VIEWDOOR HEAD NOTE:SEE ARCHITECTURAL DETAILS 2 & 5/A8.04NOTE:SEE ARCHITECTURAL DETAILS 3 & 6 /A8.04WINDOW SYSTEM(NOT BY KINGSPAN)EXPOSED SEALANT(NOT BY KINGSPAN)FLASHING(NOT BY KINGSPAN)PANEL SYSTEM(NOT BY KINGSPAN)14" - 14 x 4" TEK 3 FASTENERSw/ WASHER @ 12" O.C.SUB FRAMING(NOT BY KINGSPAN)FASTENER AS REQUIREDATTACHED TO STRUCTURAL MEMEBER(NOT BY KINGSPAN)WINDOW SYSTEM(NOT BY KINGSPAN)EXPOSED SEALANT(NOT BY KINGSPAN)FIELD CUT PANELSAS REQUIREDFLASHING(NOT BY KINGSPAN)PANEL SYSTEM(NOT BY KINGSPAN)CONTINUOUS BUTYL SEALANT14" - 14 x 4" TEK 3 FASTENERSw/ WASHER @ 12" O.C.SUB FRAMING(NOT BY KINGSPAN)CONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTDOOR FRAME(NOT BY KINGSPAN)EXPOSED SEALANT(NOT BY KINGSPAN)FIELD CUT PANELS AS REQUIREDFLASHING(NOT BY KINGSPAN)PANEL SYSTEM(NOT BY KINGSPAN)CONTINUOUS BUTYL SEALANT14" - 14 x 4" TEK 3 FASTENERSw/ WASHER @ 12" O.C.SUB FRAMING(NOT BY KINGSPAN)NOTE:SEE ARCHITECTURAL DETAILS 1, 2, & 5/A8.01NOTE:SEE ARCHITECTURAL DETAILS 2 & 5/A8.04DOOR FRAME(NOT BY KINGSPAN)EXPOSED SEALANT(NOT BY KINGSPAN)FLASHING(NOT BY KINGSPAN)PANEL SYSTEM(NOT BY KINGSPAN)14" - 14 x 4" TEK 3 FASTENERSw/ WASHER @ 12" O.C.SUB FRAMING(NOT BY KINGSPAN)FASTENER AS REQUIREDATTACHED TO STRUCTURAL MEMEBER(NOT BY KINGSPAN)CONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTBUTT JOINT TO OTHERPLAN VIEWSCALE: N.T.S.MP-1 CONTINUOUS MENDINGPLATE w/ POP RIVETS @ 12" O/CATTACHED TO STUD FRAMINGPRIOR TO PANEL INSTALLATIONCONTINUOUS BUTYLSEALANT WITH MARRIAGEBEAD TO HORIZONTALPANEL JOINTVERTICAL SUPPORT(NOT BY KINGSPAN).$55,(5Œ5$,/6(7.$55,(5Œ&/,3,1%87</SEALANT AT FASTENERLOCATIONS5" MIN.(2) 14" - 14 x 4" TEK 3FASTENERS w/o WASHERMETAL PANEL SYSTEM(NOT BY KINGSPAN)SCALE: N.T.S.PLAN VIEWPANEL TO GLAZINGKARRIERŒ RAILKIP 603DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:3/31/2015 3:15:49 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details. 293430283233353631SECTION VIEWSOFFIT TO WALLSCALE: 3" = 1'-0"SECTION VIEWFASCIA TO SOFFITSCALE: 3" = 1'-0"14" - 14 x 4" TEK 3FASTENERSw/ WASHER @ 12" O.C.METAL PANEL(NOT BY KINGSPAN)SUB FRAMING(NOT BY KINGSPAN)CONTINUOUS BUTYL SEALANTSOFFIT PANEL(NOT BY KINGSPAN)SOFFIT PANEL(NOT BY KINGSPAN)BUTYL SEALANTFASTENER AS REQUIRED(NOT BY KINGSPAN)PANEL SYSTEM(NOT BY KINGSPAN)SUB FRAMING(NOT BY KINGSPAN)SECTION VIEWPARAPETSCALE: 3" = 1'-0"PARAPET FRAMING & FLASHING(NOT BY KINGSPAN)14" - 14 x 4" TEK 3FASTENERSw/ WASHER @ 12" O.C.METAL PANEL(NOT BY KINGSPAN)SUB FRAMING(NOT BY KINGSPAN)NOTE:SEE ARCHITECTURAL DETAIL 4/A8.02NOTE:SEE ARCHITECTURAL DETAIL 11/A8.02BUTYL SEALANTFILL VOIDS w/ F.I.P.FLEXIBLE FLASHING(NOT BY KINGSPAN)4" DP3 FASTENER@ 12" O.C.KIP 604DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:3/31/2015 3:15:51 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details. FOR PRODUCTION USE:CHK BY STRETCH OUT FOR PRODUCTION USE:CHK BY STRETCH OUT FOR PRODUCTION USE:CHK BY STRETCH OUT FOR PRODUCTION USE:CHK BY STRETCH OUT FOR PRODUCTION USE:CHK BY STRETCH OUT FOR PRODUCTION USE:CHK BY STRETCH OUT FOR PRODUCTION USE:CHK BY STRETCH OUT FOR PRODUCTION USE:CHK BY STRETCH OUT FOR PRODUCTION USE:CHK BY STRETCH OUTMENDING PLATE26 GA. IMPERIAL WHITE SEMP-15CT-3CAP TRIM26 GA. IMPERIAL WHITE SEBLANK WIDTH: 6.00122ƒ3COLOR12OC-1OUTSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 5.00121222COLOROC-2OUTSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 5.00IC-2INSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 7.00ƒ1212COLORBLANK WIDTH:6.00IC-1INSIDE CORNER26 GA. IMPERIAL WHITE SECOLORƒ121233BLANK WIDTH: 7.00FOR PRODUCTION USE:CHKBYSTRETCH OUTFOR PRODUCTION USE:CHKBYSTRETCH OUT FOR PRODUCTION USE:CHK BY STRETCH OUT FOR PRODUCTION USE:CHKBYSTRETCH OUT FOR PRODUCTION USE:CHK BY STRETCH OUT FOR PRODUCTION USE:CHK BY STRETCH OUT FOR PRODUCTION USE:CHK BY STRETCH OUT FOR PRODUCTION USE:CHK BY STRETCH OUT FOR PRODUCTION USE:CHK BY STRETCH OUT FOR PRODUCTION USE:CHK BY STRETCH OUT OC-3OUTSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 8.00IC-3INSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 7.00OC-4OUTSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 5.00IC-4INSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 7.00FOR PRODUCTION USE:CHKBYSTRETCH OUT FOR PRODUCTION USE:CHKBYSTRETCH OUT 1212ƒ22COLOR331212COLORƒ122122ƒCOLOR121233COLORƒ212212COLORƒ121233ƒCOLOROC-5OUTSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 5.00IC-5INSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 7.00121222COLORƒ123312COLORƒOC-6OUTSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 5.00IC-6INSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 7.001212121222COLORƒƒ33COLOROC-7OUTSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 5.00IC-7INSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 8.00121222ƒCOLOR1212412212COLOROC-8OUTSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 5.00IC-8INSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 7.00121222COLORƒ121233COLORƒƒFOR PRODUCTION USE:CHKBYSTRETCH OUT FOR PRODUCTION USE:CHKBYSTRETCH OUT FOR PRODUCTION USE:CHKBYSTRETCH OUTOC-9OUTSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 7.00OC-10OUTSIDE CORNER26 GA. IMPERIAL WHITE SEIC-9INSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 5.00121233ƒCOLOR122122ƒCOLORIC-10INSIDE CORNER26 GA. IMPERIAL WHITE SEBLANK WIDTH: 5.00BLANK WIDTH: 7.00121222COLOR12ƒ3COLORƒ312PLEASE VERIFYKIP 701DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:3/31/2015 3:15:52 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details. 26 GA. IMPERIAL WHITEFLATSTOCKFS-1(2) BEADS OFBUTYL SEALANTFIELD NOTCHAS REQUIREDTRIM END LAP.$55,(5Œ5$,/16 GA. GALV. (BARE)"J" CLIP18 GA. BAREJC-1KARRIER RAIL MUST BE 50ksi STEEL. 33ksi STEEL WILL NOT BE ALLOWEDKIP 702DATEDRAWNSCALEJOB No.SHEETJOB NAMEPL03/04/15AS NOTEDM15 25376SWEDISH EDMONDS ACCDRAFTSMAN: CONTACT NUMBER: CONTACT NAME: SHOPS CHECKED BY: JOB NAME: CUSTOMER NAME: JOB LOCATION: PROJECT COORDINATOR: BY Deland FL. ,Modesto CA., Columbus OH. www.kingspanpanels.us Fax: (209) 531-9055, Tel: (209) 5319091 R REVISIONS THESE SHOP DRAWINGS WERE CREATED USING THE FOLLOWING INFORMATION SUPPLIED BY CUSTOMER AS THE BASIS OF DESIGN: DATE:PLANS 6/10/14 NBBJ - ARCH SETSHEETƑAPPROVED AS NOTED Ƒ APPROVED AS SUBMITTED Ƒ REVISE / RESUBMIT SIGNATURE: DATE:3/31/2015 3:15:54 PMKingspan drawings for reference of panel layout only.Northshore drawings conforming to NBBJ comments perreturned submittal PAAN 0169-074219001-0 will takepresedence over information representied in these details. NBBJ: PREVIOUSLYREVIEWED INFORMATIONNOT REVIEWED W/RE-SUBMITTAL NBBJ: CONTINUOUS BUTYL SEALANTPER MANUFACTURER'S STANDARDDETAIL - OPTIONAL BEAD IN FORWARDGROOVE RECOMMENDED (TYP) NBBJ: SEE MARKUPS ON S01-DET NBBJ: SEE MARKUPS ON S01-DET NBBJ: SEE MARKUPS ON S01-DET NBBJ: GC NOTE -COLD FORMEDMETAL FRAMINGTO EDGE OFSEISMIC JOINTGAPNBBJ: SEALANT BOTHSIDES OF TRIM TOMAINTAIN AIR BARRIERCONTINUITY W/ STUD (TYP)NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP)NBBJ: GC NOTE - FLEXI-FLASHAS REQUIRED FOR AIRBARRIER CONTINUITY TOINNER SEAL (TYP) NBBJ: SEE MARKUPS ON S01-DETNBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: NO VOID - CUTPANEL ENDS TOREQUIRED PROFILENBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: SEE MARKUPS ON S01-DET NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: SEE MARKUPS ON S01-DET NBBJ: SEE MARKUPS ON S01-DETNBBJ: GC NOTE - FLEXI-FLASHAS REQUIRED FOR AIRBARRIER CONTINUITY TOINNER SEAL (TYP) NBBJ: GC NOTE - FLEXI-FLASHAS REQUIRED FOR AIRBARRIER CONTINUITY TOINNER SEAL (TYP) NBBJ: SEE MARKUPS ON S01-DET NBBJ: SEE MARKUPS ON S01-DETNBBJ: PANEL & FLASHINGSEALED TO UNDERSIDE OFSILL PAN SIMILAR TO 10-DET NBBJ: SEE MARKUPS ON S01-DETNBBJ: GC NOTE -MAINTAIN CONTINUOUSROOF MEMBRANE SEALTO INSULATED METALPANEL SYSTEMNBBJ: CONFIRMWOOD NAILERSPER RFI-187 NBBJ: SEE MARKUPS ON S01-DET NBBJ: SEE MARKUPS ON S01-DETNBBJ: PROVIDEDETAILING & DESIGNINFO FOR SOFFITPANELS & RAILS NBBJ: SEE MARKUPS ON S01-DETNBBJ: CONFIRMWOOD NAILERSPER RFI-187NBBJ: GC NOTE - MAINTAINROOF MEMBRANECONTINUITY TOINSULATED METAL PANELSYSTEM NBBJ: ALTERNATE DETAILSUGGESTED, EXTENDINGINSULATED PANELS DOWN TOWINDOW HEAD & ANCHORINGHSS TO "KARRIER" RAIL ASSHOWN. PLEASE CONFIRM IFVIABLE. NBBJ: GC NOTE - MAINTAIN ROOFMEMBRANE CONTINUITY TOINSULATED METAL PANEL SYSTEMNBBJ: CONFIRMWOOD NAILERSPER RFI-187 NBBJ: PROVIDEDETAILING &DESIGN INFO FORSOFFIT PANELS &RAILS NBBJ: SEE MARKUPS ON S01-DETNBBJ: CONFIRMWOOD NAILERSPER RFI-187NBBJ: GC NOTE - MAINTAIN ROOFMEMBRANE CONTINUITY TOINSULATED METAL PANEL SYSTEM NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: SEAL BETWEENSILL PAN & TOP OFPANEL TRIM (TYP)NBBJ: EXTEND SILL PANTO ALLOW FOR INNERSEAL CONTINUITY NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: SEAL BETWEENSILL PAN & TOP OFPANEL TRIM (TYP)NBBJ: EXTEND SILL PANTO ALLOW FOR INNERSEAL CONTINUITY NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: WINDOW JAMB TOADJOIN ENTRY FRAME.INSULATED PANEL WALLSLIVER NOT REQUIRED. NBBJ: SEE MARKUPS ON S01-DETNBBJ: SEAL BOTTOMOF PANEL TRIM TOFOUNDATIONINSULATION (TYP)NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: CORNER JOINT ALTERNATE 1:KINGSPAN STANDARD MITEREDOUTSIDE CORNER DETAILKPH-OC-01-MTLV W/ BACKUP ANGLE &MARRIAGE BEADS TO HORIZONTALSEALANT JOINTS (SEE MARKUPS ON48/DET FOR ALTERNATE 2) NBBJ: CORNER JOINT ALTERNATE 2:PANELS OVERLAPPED AS SHOWN. OVERLAPPING PANEL KERFED ONBACKSIDE TO PROVIDE THERMALBREAK, PANEL HORIZONTAL SEALANTBEADS CONTIGUOUS W/ VERTICALBEADS. (SEE MARKUPS ON 47/DET FORALTERNATE 1)KERFHORIZONTALSEALANT BEADSCONTIGUOUS W/VERTICAL BEADS(TYP) NBBJ: ALTERNATE 1 OR 2CORNER DETAIL PER MARKUPSON 47/DET OR 48/DET NBBJ: SEAL BOTTOMOF PANEL TRIM TOFOUNDATIONINSULATION (TYP)NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: SEAL BOTTOMOF PANEL TRIM TOFOUNDATIONINSULATION (TYP)NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: SEE MARKUPS ON S01-DET NBBJ: SEE MARKUPS ON S01-DET NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP) NBBJ: NOTE - COORDINATEDETAIL W/ CURRENT 7/A8.06NBBJ: ALTERNATE 1 OR 2CORNER DETAIL PER MARKUPSON 47/DET OR 48/DET NBBJ: BACKUP TRIM & BUTYL MARRIAGEBEAD TO HORIZONTAL PANEL SEAL PERKINGSPAN STANDARD DETAIL TO MAINTAINAIR BARRIER CONTINUITY & COVER FOAMPANEL END OPEN TO WALL CAVITY(TYP) NBBJ: SEE MARKUPS ON S01-DET NBBJ: GC NOTE -PROVIDE FRAMINGBACKUP ADJACENTCURTAINWALL JAMBNBBJ: GC NOTE -FLEX-FLASHING TOCURTAINWALL JAMB INNERSEAL AS NECESSARY TOMAINTAIN AIR BARRIERNBBJ: EXTENDINSULATED PANEL TOCURTAINWALL JAMBR.O. PROFILENBBJ: TWOPART FLASHINGNBBJ: CURTAINWALL PRIMARYSEAL @ LEADING EDGE OFJAMB - MAINTAIN AIR BARRIERTO THAT POINT NBBJ: METAL TRIM W/"V" MOVEMENT BENDSEALED TO PANELS NBBJ: COMPRESSIBLEFOAM FILL NBBJ: CONFIRMWOOD NAILERSPER RFI-187NBBJ: GC NOTE - MAINTAIN ROOFMEMBRANE CONTINUITY TOINSULATED METAL PANEL SYSTEM NBBJ: CONFIRMWOOD NAILERSPER RFI-187NBBJ: GC NOTE - MAINTAINROOF MEMBRANE CONTINUITYTO SKYLIGHT SYSTEM NBBJ: SEE MARKUPS ON 74-DETNBBJ: CONFIRMWOOD NAILERSPER RFI-187 NBBJ: SEE MARKUPS ON 74-DET NBBJ: SEE MARKUPS ON 73-DETNBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP)NBBJ: CONFIRMWOOD NAILERSPER RFI-187 NBBJ: ALTERNATE 1 OR 2CORNER DETAIL PER MARKUPSON 47/DET OR 48/DET NBBJ: ALTERNATE 1 OR 2CORNER DETAIL PER MARKUPSON 47/DET OR 48/DET NBBJ: TRIM ENDS SO NO EXPOSEDFOAM TO WALL CAVITY (TYP) NBBJ: TRIM ENDS SO NOEXPOSED FOAM TO WALLCAVITY (TYP) NBBJ: INSULATED METAL PANEL -MAINTAIN AIR BARRIERCONTINUITY & SEAL TO SILL PAN NBBJ: ALTERNATE 1 OR 2CORNER DETAIL PER MARKUPSON 47/DET OR 48/DETNBBJ: INSIDE CORNERPER MARKUPS ON 65-DETNBBJ: TWO PARTTRIM W/ THERMALBREAKNBBJ: GC NOTE - PROVIDEFLEXI-FLASH AS REQUIREDTO MAINTAIN AIR BARRIERCONTINUITY TO INNER SEAL NBBJ: INSULATEDMETAL PANELSYSTEM BACKUPNBBJ: THERMALLY BROKENTRANSITION DETAIL W/ AIRBARRIER CONTINUITY AS MARKEDUP ELSEWHERE IN THIS SUBMITTAL NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP)NBBJ: SEAL BOTTOMOF PANEL TRIM TOFOUNDATIONINSULATION (TYP) NBBJ: NO EXPOSEDFOAM TO CEILING ORWALL CAVITIES (TYP) NBBJ: THERMALLY BROKEN& SEALED 2 PART ANGLEFLASHING RECOMMENDEDIN LIEU OF CHANNEL (TYP)NBBJ: SEAL BOTTOMOF PANEL TRIM TOFOUNDATIONINSULATION (TYP) NBBJ: NOT REVIEWEDUNDER THIS SUBMITTAL NBBJ: NOT REVIEWEDUNDER THIS SUBMITTAL NBBJ: NOT REVIEWEDUNDER THIS SUBMITTAL NBBJ: NOT REVIEWEDUNDER THIS SUBMITTAL NBBJ: NOT REVIEWEDUNDER THIS SUBMITTAL NBBJ: NOT REVIEWEDUNDER THIS SUBMITTAL NBBJ: NOT REVIEWEDUNDER THIS SUBMITTAL NBBJ: NOT REVIEWEDUNDER THIS SUBMITTAL NBBJ: NOT REVIEWEDUNDER THIS SUBMITTAL NBBJ: NOT REVIEWEDUNDER THIS SUBMITTAL NBBJ: NOT REVIEWEDUNDER THIS SUBMITTAL NBBJ: NOT REVIEWEDUNDER THIS SUBMITTAL NBBJ: NOT REVIEWEDUNDER THIS SUBMITTAL NBBJ: NOT REVIEWEDUNDER THIS SUBMITTAL NBBJ: NOT REVIEWEDUNDER THIS SUBMITTAL