074219.001-1 Insulated Metal Panel Backup Wall Assemblies REVISED_NBBJ-PAAN.pdfCONTRACTOR SUBMITTAL ISSUE TO NBBJ
DATE ISSUED Apr 30, 2015
COMPANY NBBJ
223 Yale Avenue North
Seattle, WA 98109
PHONE / FAX (206) 223-5555
PROJECT NUMBER 100822.06
PROJECT NAME SMC Edmonds ACC
ATTENTION: Barb Gipple
NBBJ Submittal
Number 169-074219-1
GC Submittal
Number 169-074219001-1
SPEC. PARAGRAPH:
SPEC. DESCRIPTION:Insulated Metal Panel Backup
Wall Assemblies
SPECIFIC ITEM:Insulated Metal Panel Backup
Wall Assemblies
CONTRACTOR ISSUED
ON:Apr 30, 2015
DATE REQUESTED
BACK:May 15, 2015
DATE RECEIVED @
NBBJ:May 1, 2015
DATE DUE BACK TO
CONTRACTOR:May 14, 2015
DATE RETURNED BY
NBBJ:
ITEMS TRANSMITTED
SENT VIA
REVIEW ACTION Partially approved as noted
REVIEW NOTE
COPIES
GC REMARKS
NBBJ COMPOSITE RESPONSE
Entered By: Andris Lapins
Entered Date: Wednesday, May 13, 2015 7:43 AM
Approved as noted per attached comments. Please provide the following:
Confirmation letter from the manufacturer stating that the installers deviations from recommended details are acceptable
and will not adversely affect system performance or warranty.
PLEASE NOTE: Previously reviewed information not reviewed with this submittal.
ISSUED BY Joe Eagle
PHONE / FAX: (206) 682-7770
CONSULTANTS REPRESENTED
Page 1 of 2
5/13/2015https://secure1.nbbj.com/CATools/Data/SubForm.aspx?SubmittalID=130456&Msg=save
05/13/15
EMAIL: JOE.EAGLE@SELLEN.COM
COPY TO: Dan Schnebele
Mark Bucek
Scott Solberg
NBBJ Amy Frerker
NBBJ Andris Lapins
NBBJ Michael Howatt
ELECTRONIC ATTACHMENTS
Page 2 of 2
5/13/2015https://secure1.nbbj.com/CATools/Data/SubForm.aspx?SubmittalID=130456&Msg=save
SUBMITTAL FOR APPROVAL
7039. - SWEDISH/EDMONDS-AMBULATORY CARE
CENTER
1 | Page
Submittal #: 169 -074219.001
Rev#: 1
Priority: HOT
Date: 04/30/2015
To: MICHAEL HOWATT From: JOE EAGLE
NBBJ SELLEN CONSTRUCTION CO., INC.
223 Yale Ave 227 WESTLAKE AVE N
Seattle, 98109 SEATTLE, WA 98109
Originator: NORTHSHORE SHEET METAL INC
Description: Insulated Metal Panel Backup Wall Assemblies
We are transmitting the following Submittal Package item(s) for your review in accordance with the
contract specifications.
Please review and respond to: JOE EAGLE, by: 5/15/2015.
Additional Notes:
Item Number Spec Section Description Details Notes
169.002. 074219 Insulated Metal Panel Backup
Wall Assebmlies
Product Data, Shop
Drawings, Coursing Layout,
Performance Data, Panel to
Panel joint detail,
cc:
REVIEWED
WITH CORRECTIONS NOTED. THIS REVIEW DOES
NOT RELIEVE THE SUBCONTRACTOR OR MATERIAL
SUPPLIER FROM RESPONSIBILITY FOR ERRORS OR
DEVIATIONS FROM DRAWINGS & SPECIFICATIONS.
SELLEN CONSTRUCTION CO.
GENERAL CONTRACTOR
Submittal: 074219001-1 Insulated Metal Panel Bac
By: joee Date: 04/30/2015
KarrierPanel™
Insulated Roof
& Wall Panels
Universal Barrier
Wall Solution
074219 Insulated Metal
Wall Panels
KarrierPanel™
2
Is a cost effective universal barrier wall alternative solution to
traditional multi-component wall systems. Comprising of a KS Series
panel and integrated rail, KarrierPanel™is the ideal barrier wall to
support secondary rainscreens systems such as metal or brick
façades.
KarrierPanel™is suitable for all building types in any climate, and
combines the thermal benefits of lightweight insulated metal panels
with the aesthetics of multiple façades.
KarrierPanel™offers a simple more time efficient alternative to
traditional multi-part façades, allowing the structure to be quickly
insulated to ensure air and watertightness as soon as possible. Once
installed the system provides 100% building envelope performance.
For more information or to request a sample, email
karrier@kingspanpanels.com.
To view an animation of the
KarrierPanel™ wall system, visit our
YouTube Channel, Kingspan TV.
Contents
3
KarrierPanel™Product Details 4
Design Flexibility 5
Build Speed 6
Thermal Performance 7
Sustainability 8
Testing and Approvals 10
Kingspan Service and Support 11
KarrierPanel™Projects 12
Construction Details 14
4
KarrierPanel™
Product Details
Product Specification
Cover Widths: 24” 30” 36” 42” (Standard)
Panel Thickness: 2” 2
1/2” 3” 4” 5” 6”
R-value: 7.5 per inch
Panel Lengths: 6’-0” to 52’-0”
Panel Joint: Double tongue and groove interlocking
rainscreen joint
Reveal Choice:3/8 reveal
Exterior Face: 26, 24 or 22 Ga. Shadowline profiled
embossed Galvalume®pre-painted steel
Interior Face: 26, 24 or 22 Ga. Shadowline profiled
embossed Galvalume®pre-painted steel
Application: Vertical and horizontal
Rail: Custom Kingspan KarrierRail
™
5
Design Flexibility
KarrierPanel™
can support a
range of
rainscreen
finishes to
compliment any
architectural
scheme.
Unique KarrierRail™
KarrierPanel™utilizes a Kingspan designed unique rail. This stable and
secure structural rail safely transmits positive loads from the multiple
façades to the structural supports behind the insulated panels.
Similarly, expansion fasteners (fab-loks) secure the exposed rail edge,
ensuring that the system safely handles negative loads as well.
The rail has been developed to fully integrate with Kingspan’s KS series
panel joint. This rail system does not penetrate the air vapor barrier and
enables multiple types of rain screens to be attached to the
KarrierPanel™rail such as brick, single skin metal, and various other
systems.
Brick Rainscreen
on KarrierPanel™
Metal Rainscreen
on KarrierPanel™
Installation is quick, simple
and easy, as the rail is
installed during normal panel
installation, and is secured
using standard panel
fasteners in a one step
procedure.
The standard rail configuration is 16 gauge Galvalume®,
50 KSI steel. Available in various lengths with a 1, 2 and
3 inch bearing surface.
Build Speed
6
Build Speed
KarrierPanel™as a single component system increases speed
of build, minimizes delays and the need for multiple trades.
Typical multi-part façade system KarrierPanel
™System
with Metal Single
Element Rainscreen
Single
Component
KarrierPanel™
Wall System
Vs
1
■Faster close-in and dry-in for reduced building costs.
■The single component system results in less labor time on-site and construction waste.
■Reduces delays in construction experienced with scheduling multiple trades.
■Increase in build speed allows faster project completion and reduces business disruption.
Thermal Performance
7
Vs
The insulated panel provides excellent thermal performance with high R-value and airtightness with an air,
water and vapor barrier.
Benefits of the KarrierPanel™Wall System Vs
Traditional Built-up Construction:
■The single component KarrierPanel™wall system combines the
superior thermal performance of IMPs with an air, water and vapor
barrier.
■More uniform temperature distribution throughout the wall ensures
moisture control.
■Eliminates energy losses associated with thermal-bridging cavity
insulation.
■Eliminates concerns over UV exposure as compared to
conventional rainscreen components.
■Eliminates the potential for compromising the Air, Vapor Barrier
(AVB) and allows for visual inspection and testing of the AVB.
■Results in quicker ROI.
Kingspan
KarrierPanel™Wall System
Di
r
e
c
t
i
o
n
o
f
h
e
a
t
f
l
o
w
Steel-framed,
Built-up Wall System
Di
r
e
c
t
i
o
n
o
f
h
e
a
t
f
l
o
w
8
Path to NetZero™
Kingspan’s long-term mission will see all our facilities achieve
NetZero energy consumption by 2020. NetZero Energy buildings,
in the simplest terms, produce as much energy as they consume.
Our insulated metal panels are a cost effective step to this high
performance goal, offering a building envelope with functionality
and design possibility.
Our Path to NetZero™app is a unique tool for the building industry that
simulates the process of achieving high performance and NetZero energy
buildings. Results indicate estimated energy cost savings, CO2, ROI and
contributions to LEED®points gained by using Kingspan Insulated
Panels.
Building professionals and owners today share a newfound enthusiasm for building envelope performance.
Driving this focus are mandates for green building, a focus on energy efficiency and recognized ROI.
EnvelopeFirst™
Kingspan’s EnvelopeFirst™is a design strategy for optimizing a
building’s performance and the first step towards NetZero energy.
The EnvelopeFirst™approach to design focuses on enclosure
performance, including durability, airtightness, and better moisture
and thermal control.
Testing and field results show that insulated metal panels (IMPs)
contribute to ROI and energy efficiency.
Start with the…
LEED®Credits
Kingspan is committed to supporting green rating systems such as
LEED®and Green Globes. Specification of effective systems and
materials is key to achieving these certifications. With this in mind,
Kingspan provides a LEED®credits guide to assist the building team
on how IMPs contribute to overall building performance and ratings
criteria.
Visit www.kingspanpanels.us/sustainability/leedinformation to
download Kingspan’s LEED®statement for project submittals.
Sustainability
Energy &
Atmosphere
Materials &
Resources
Innovation
In Design
Indoor
Environmental
Quality
Sustainable
Sites
9
Goal of an EPD
An EPD’s goal is transparency. Knowing what’s in the product you
chose and its environmental impact. An important aspect of an EPD
is to provide the basis of a fair comparison of products and services
by its environmental performance. EPDs can reflect the continuous
environmental improvement of products and services over time and
are able to communicate and add up relevant environmental
information along a product’s supply chain.
UL Certified
To add credibility to our findings, we engaged UL Environment to verify
the results of our EPD. UL has been impartially assessing products
since 1894 for safety and viability and have conducted numerous
environmental evaluations. UL certified EPDs are based on ISO
compliant standards.
Our EPD indicates that raw materials are the dominant impact
across our products life cycle, therefore we are consciously working
with our suppliers to improve this.
This data confirms our company policy of utilizing more recycled
and less virgin resources whenever possible.
To learn about our sustainability
journey and download the EPD or
App, visit:
www.pathtonetzero.com
EPD (Environmental Product Declaration)
Kingspan Insulated Panels North America,
has been awarded the first of its
kind UL certified ISO compliant
Environmental Product Declaration
(EPD). The EPD describes environmental
manufacturing footprints from cradle to
grave based on an ISO compliant Life
Cycle Assessment (LCA).
What is an EPD
An EPD is a third party verified, internationally recognized disclosure
of a product’s environmental impact, from cradle to grave based on
an ISO compliant Life Cycle Assessment (LCA).
Kingspan’s LCA calculates the environmental footprint at each stage
of the supply chain, manufacturing processes, product use and
end of life. All the significant environmental impacts associated with
the product, including the impact on water, air, land and climate
change are reported based on ISO LCA standards.
Testing and Services
10
Performance Requirements and Product Listings:
Kingspan insulated panels meet specific building envelope performance criteria and requirements stipulated by US
and Canadian building codes. Panels are tested in accordance with UL, ULC, FM and ASTM approval standards,
testing methods and procedures. Kingspan insulated panels are listed by FM Global and Warnock Hersey.
Test Procedure Results
Fire FM-4880 Passed: Class 1 Fire Rating of Insulated Wall or Wall and Roof / Ceiling
Panels, Interior Finish Materials or Coatings, and Exterior Wall Systems
ASTM E84 Flame spread <25, smoke developed <450
CAN/ULC-S101 Fire endurance tests: 10 min and 15 min stayed in place
CAN/ULC-S102 Flame spread: 20, Smoke developed: 350 for panel with facings
CAN/ULC-S127 Flame spread <500 for foam core
CAN/ULC-S134 Passed: Standard method of test for fire of exterior wall assemblies
ULC/ORD-C376 Passed: Fire growth of foamed plastic insulated building panels
in a full scale room configuration
NFPA 259 Tested for potential heat of building materials
NFPA 268 Passed: Standard test method for determining ignitability of exterior wall
assemblies using a radiant heat energy source
NFPA 285 Passed: Standard Fire Test Method for Evaluation of Fire Propagation
Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing
Combustible Components.
Structural FM-4881 Passed: Class +110/-154 Zone H Class
+100/-140 Zone HM – LM
ASTM E72 Vacuum chamber tested. Panel load / span and deflection
tables are available
Thermal Performance ASTM C518 R-value per inch = 7.5 h
.ft2.°F/Btu.in
Air Infiltration ASTM E283 0.003 CFM/ft
2 of Panel Area at 6.24 psf
Water ASTM E331 No uncontrolled water penetration at 20 psf differential pressure
AAMA 501.1 Dynamic water pressure testing – no sign of water
leakage at 15 psf
Fatigue Tests Cyclic test to positive and negative The panels exceeded 2 million alternate cycles
wind loading to ± L/180 deflection without failure or damage
Bond Strength ASTM D1623 Panels tested for tensile bond strength of metal to foam
Sample placed in an autoclave device and pressurized to
2 PSI at 212 °F for 21/2 hours
No skin delamination with direct pull off pressure up to 1188 psf
The above tests were conducted on various Kingspan products, and not all products may comply with the tests shown. If you have any questions on a specific product and/or test, please ask a
representative of Kingspan Technical Services. Kingspan does not assure compliance with any plans or specifications and it remains the responsibility of the customer to confirm compliance of
the product with applicable local, state and national codes and other laws or regulations.
Kingspan Service
and Support
11
Sales Team
Our regionally based sales team can provide assistance
on any project from the design stage through to site
installation.
Find your local sales rep on our website.
Canada - www.kingspanpanels.ca/findasalesrep
USA - www.kingspanpanels.us/findasalesrep
Email us:
Technical and Energy Services:
technicalservice@kingspanpanels.com
Installation:
installation@kingspanpanels.com
Marketing:
marketingdept@kingspanpanels.com
Samples:
samplesdept@kingspanpanels.com
Follow Kingspan on:
Langley, BC
Modesto, CA
Caledon, ON
Columbus, OH
Deland, FL
Technical Service
Kingspan provides a comprehensive technical advisory service to
assist architects, engineers, specifiers and installation contractors
with building design, product application and site work installation
training and challenges.
Energy Service
Kingspan offers a performance energy modeling service on select
projects to help design teams understand scenarios contributing to
optimizing the energy efficiency of insulated metal panel assemblies
based on meeting or exceeding ASHRAE 90.1 requirements.
Customer Service
Our dedicated team provides focused customer service for all pre and
post-order administration, delivery scheduling, and installer support,
ensuring a seamless coordinated customer experience.
Marketing Support
Our marketing team aims to provide a fast turnaround on standard
sample and literature requests, eliminating delays with planning and
client approval of material, so that your project begins on time.
Additional marketing support is provided through the use of project
case studies.
Field Service Support
Kingspan’s Field Service Engineering Team offer customers free
contractor training on the installation of new and existing products,
site inspection services as well as advice on mechanical handling
solutions.
KarrierPanel™Projects
12
13
Construction Details KarrierPanel™with Metal
14
Base at Overhang – Horizontal IMP Vertical Rainscreen
Single skin panel (installed vertically)
Hat channel – as required
Set hat channel in butyl sealant
at fastener locations
Continuous butyl sealant
Continuous butyl sealant both sides of trim
1/4” – 14 hex head fasteners with washer
Base channel set in sealant (not by Kingspan)
Fastener to concrete (not by Kingspan)
Vertical supports (not by Kingspan)
Single skin panel base flashing
Construction Details KarrierPanel™with Metal
15
Intermediate Support – Horizontal IMP Vertical Rainscreen
1/4” – 14 hex head fasteners with washer
Single skin panel (installed vertically)
Continuous KarrierRail™(KarrierRail™
available in 1”, 2” & 3” faces)
Expansion fastener as required
Set KarrierRail™in butyl sealant at fastener locations
Vertical support at 16” O.C. (not by Kingspan)
1”
Continuous butyl sealant
Continuous butyl sealant (optional)
Male
joint
Wall panel
installation
direction
Female
joint
Construction Details KarrierPanel™with Metal
16
Parapet Detail – Horizontal IMP Vertical Rainscreen
FIP insulation – as required
Single skin panel parapet assembly Continuous butyl sealant
Fastener to parapet backer
(not by Kingspan)
Membrane roof and parapet
backer (not by Kingspan)
Parapet blocking (not by Kingspan)
Wrap membrane over panel face
(not by Kingspan)
Set hat channel in butyl sealant
at fastener locations
Single skin panel (installed vertically)
Hat channel – as required
1/4” – 14 hex head fasteners with washer
Construction Details KarrierPanel™with Metal
17
Base Detail - Vertical IMP Horizontal Rainscreen
Single skin panel (installed horizontally)
Expansion fastener – as required
1/4” – 14 hex head fasteners with washer
Continuous butyl sealant both sides of trim
with marriage bead to vertical panel joint
Set KarrierRail™in butyl sealant at fastener locations
Continuous KarrierRail™(KarrierRail™available in 1”, 2” & 3” faces)
Single skin panel continuous
starter / flashing
Single skin panel base flashing
Continuous butyl sealant
Base angle with min. 3” vert. leg for panel attachment
set in sealant (not by kingspan)
Construction Details KarrierPanel™with Metal
18
Intermediate Support – Vertical IMP Horizontal Rainscreen
1/4” – 14 hex head fasteners with washer Horizontal support (not by Kingspan)
Expansion fastener as required Continuous butyl sealant (optional)
Continuous KarrierRail™(KarrierRail™
available in 1”, 2” & 3” faces)
Single skin panel (installed horizontally)
Set KarrierRail™in butyl sealant at fastener locations Continuous butyl sealant
Wall panel
installation direction
1”
Male
joint
Female
joint
Construction Details KarrierPanel™with Metal
19
Low Eave Detail – Vertical IMP
Horizontal Rainscreen
Expansion fastener – as required
FIP insulation – as required
Refer to 900/1000 series roof panel
details for additional information
1/4” – 14 hex head fasteners
with washer
Continuous butyl sealant with marriage
bead to vertical panel joint
Eave strut (not by Kingspan)
Continuous KarrierRail™(KarrierRail™available in 1”, 2” & 3” faces)
Single skin panel (installed horizontally)
Construction Details KarrierPanel™with Brick
20
Base Detail – Horizontal IMP
1/4” – 14 through fasteners with 1
1/8” bonded washer (as required for wind load)
Vertical metal stud wall (not by Kingspan)
Face brick (not by Kingspan)
Brick
Air
gapStud wall
Panel
thickness
Set panel in continuous butyl sealant
Waterproofing membrane below grade (not by Kingspan)
Flexible membrane flashing (not by Kingspan)
Masonry drainage and venting (not by Kingspan)
Mortar net (not by Kingspan)
Brick tie – HB wing nut with pintle (spacing to be determined by the engineer of record)
Construction Details KarrierPanel™with Brick
21
Engaged Panel Detail – Horizontal IMP
1/4” – 14 hex head fasteners without washer
12 Ga. stainless steel hidden fastener clip (1 per panel,
per support) set clip in butyl sealant
Face brick (not by Kingspan)
Brick
Air
gap Stud wall
Panel
thickness
Continuous butyl sealant at interior panel joint
Continuous butyl sealant at exterior panel joint
Vertical metal stud (not by Kingspan)
Brick tie – HB wing nut with pintle (spacing to be
determined by the engineer of record)
Brick tie – HB wing nut with pintle (spacing to be
determined by the engineer of record)
Construction Details KarrierPanel™with Brick
22
Framed Opening – Horizontal IMP
1/4” – 14 pancake through fasteners
with 1 1/8” bonded washer
(as required for wind load)
Face brick (not by Kingspan)
Masonry drainage and venting
(not by Kingspan)
Shelf angle (not by Kingspan)
Metal flashing with drip edge
set in sealant (by mason)
Backer rod and sealant (not by Kingspan)
Window system (not by Kingspan)
Self-adhering vapor barrier at window
rough opening (not by Kingspan)
Mortar net (not by Kingspan)
Vertical metal stud wall
(not by kingspan)
Membrane termination bar, fasteners
and sealant (by mason)
Set panel in continuous butyl sealant
Self-adhering membrane with up turned
ends to form end dams (by mason)
Brick tie – HB wing nut with pintle
(spacing to be determined by the
engineer of record)
Construction Details KarrierPanel™with Brick
23
Framed Opening – Horizontal IMP
Face brick (not by Kingspan)
8” hollow concrete block (not by Kingspan)
Slip sheet to protect panels (not by Kingspan)
Set panel in continuous butyl sealant
Self-adhering vapor barrier (not by Kingspan)
Wrap roof membrane over panel face
(not by Kingspan)
Masonry fastener (as required for
wind load) (not by Kingspan)
Parapet cap and metal flashing cap,
sealant and weather tightness
(not by Kingspan)
Brick tie – HB wing nut with pintle to masonry
(spacing to be determined by the engineer of record)
06/2014
Kingspan USA Kingspan Canada
Deland, FL : 386-626-6789 Caledon, ON : 905-951-5600
Modesto, CA : 209-531-9091 Langley, BC : 604-607-1101
www.kingspanpanels.us www.kingspanpanels.ca
For the product offering in other markets please contact your local sales representative or visit www.kingspanpanels.com
Care has been taken to ensure that the contents of this publication are accurate, but Kingspan Limited and its subsidiary companies do not accept responsibility for errors or for
information that is found to be misleading. Suggestions for, or description of, the end use or application of products or methods of working are for information only and
Kingspan Limited and its subsidiaries accept no liability in respect thereof.
Follow Kingspan on:
REVISION: 04/26/13
Henry Company 999 N. Sepulveda, Ste 800, El Segundo CA 90245-2754
Technical Services- Phone (800) 486-1278 – Email: techservices@henry.com
www.henry.com
TECHNICAL DATA SHEET
Blueskin SA
Self-Adhesive Air/Vapor Barrier Membrane
Typical Physical Properties
-Color
-Thickness
-Application Temp
-Service Temp
-Elongation
(ASTM D412-modified)
-Tensile Strength
(Membrane)
(ASTM D412- modified)
-Tensile Strength (Film)
(ASTM D882)
-Minimum Puncture
Resistance – Membrane
(ASTM E154)
-Watertightness
(CAN/CGSB-37.58-M86)
-Nail Sealability
(ASTM D1970)
Blue
40 mils (1.0 mm)
41ºF minimum
Minus 40°F to 158°F
200% minimum
500 psi minimum
5000 psi minimum
40 lbf.
Pass
Pass
-Low Temperature Flexibility
@ -22°F (CGSB 37-GP-56M)
-Water Vapor Transmission
(ASTM E96 water method)
(ASTM E96 desiccant method)
-Lap Peel Strength @ 39°F
(ASTM D903 180° bend)
-Water Absorption
(ASTM D570)
-Air Leakage @ 75 Pa
(ASTM E2178)
-Air Leakage After 3000 Pa Test
(ASTM E330-90)
-Assembly Air Leakage
@ 75 Pa (ASTM E2357)
-Crack Cycling
(ASTM C836)
Pass
0.86 perms
(49 ng/Pa.s.m2)
0.03 perms
(2 ng/Pa.s.m²)
25.0 lbf/in
(> 4378.4 N/m)
0.1%
0.0001 cfm/ft2
(0.0005 L/s.m.²)
No change
0.001 cfm/ft2
(0.005 L/s.m.²)
Pass
Packaging
-Roll length
-Roll width
-Top Surface
-Bottom Surface
75 ft.
48”, 36”, 18”, 12”, 9”, 6”, 4”
Blue Film
Siliconized Release Film
-Gross Coverage (Net Coverage*)
36”
18”
*Based on 2” laps
225 ft2 (212 ft2)
112.5 ft2 (100 ft2)
(Side and end laps)
Description
Blueskin SA is a self-adhering membrane consisting of an SBS rubberized asphalt compound, which is integrally laminated to a blue
engineered thermoplastic film. The membrane is specifically designed to be self-adhered to a prepared substrate, providing an
air/vapor/water barrier in full wall applications or as penetration/flashing membrane with other air barrier systems. Blueskin SA, in
assemblies with primer and BES Sealant meet ASTM E-2357 – reference guide specification for details.
Features
• SBS modified membrane, flexible at low temperatures
• Impermeable to air, moisture vapor and water
• Assemblies of Blueskin SA, primer and sealant meet ASTM E-2357 air barrier performance standard.
• Excellent adhesion to prepared substrates of concrete, concrete block, primed steel, aluminum mill finish, anodized
aluminum, galvanized metal, gypsum board and plywood
• Compatible with Henry Air-Bloc liquid air barrier membranes
• Membrane is self-gasketing when penetrated and under compression with self-tapping screws
REVISION: 04/26/13
Henry Company 999 N. Sepulveda, Ste 800, El Segundo CA 90245-2754
Technical Services- Phone (800) 486-1278 – Email: techservices@henry.com
www.henry.com
Blueskin SA Self-Adhesive Air/Vapor Barrier Membrane
Storage
Store rolls on end, on original pallets or elevated platform. Protect from weather or store in an enclosed area not subject to heat over
120°F.
Limitations
Not designed for permanent exposure to weather - protect as soon as possible, however can be exposed up to 30 days if necessary to
accommodate construction scheduling. Not to be used in direct contact with flexible PVC/vinyl membranes or gaskets.
Uses
Blueskin SA is designed for use as a self-adhered sheet air, vapor and rain barrier. Its principal application is on walls of either
masonry, concrete or gypsum board. It can also be used as a transition sheet in conjunction with Henry Liquid Membranes where
greater movement is anticipated, due to its high strength. Blueskin SA is also used for tying into metal on curtain walls, windows and
doorframes.
Surface Preparation
Acceptable substrates are precast concrete, cast-in place concrete, concrete block, primed steel, aluminum mill finish, anodized
aluminum, galvanized metal, gypsum board including Dens Glass Gold. All surfaces to receive Blueskin SA must be clean of oil,
dust and excess mortar. Strike masonry joints flush. Concrete surfaces must be smooth and without large voids, spalled areas or
sharp protrusions. Concrete must be cured a minimum of 14 days and must be dry before Blueskin SA is applied. Where curing
compounds are used, they must be clear resin based, without oil, wax or pigments.
All surfaces to receive Blueskin SA require an application of Blueskin Adhesive or Spray Prep, applied by lambs wool roller,
brush or spray at the rate of 85 to 250 ft2/gallon depending on porosity and texture of surface and allowed to dry for 30 minutes before
Blueskin SA is applied. Ensure that all surfaces receive Blueskin SA in the same day. Alternatively, apply Aquatac by roller at a
rate up to 500 ft2/gallon. Allow to dry to a tacky film.
Application
Refer to Blueskin SA Guide Specification for detailed application information.
Blueskin SA must be lapped a minimum of 2” on both sides and end laps. Position membrane for alignment; remove protective film
and press firmly in place. When membrane is entirely in place, roll membrane including seams with a counter top roller to ensure full
contact. When using membrane with brick ties, position membrane, press in place and cut for ties or projections. Seal around any
openings and at leading edge at the end of the days work with Henry #925 BES Sealant, Polybitume, Air-Bloc 21, or Air-Bloc 21
FR. Membrane applied to the underside of the substrate (i.e. ceilings) requires mechanical fastening through treated wood or
galvanized metal strapping, or have insulation mechanically fastened. Fastening must take place immediately after installation of
membrane. Space strapping on 18” centers, running perpendicular to the side laps.
Detail work must be carefully carried out to ensure continuous air tightness of the membrane. It is recommended that mechanical
attachment be made to all window and doorframes, or a properly designed sealant joint be provided.
Insulation Application over Membrane
Insulation Clips: Insulation clips should be mechanically fastened through the membrane into the substrate with a self-tapping screw.
Apply number of insulation clips as recommended by the insulation manufacturer.
Insulation Adhesive: Henry Air-Bloc 21 –where permitted by local VOC regulations - should be applied to insulation boards in a
serpentine pattern to restrict movement of air behind the insulation. Alternatively, a full coat notched trowel application of Henry Air-
Bloc 21 may be applied to the back of the board. Press insulation firmly in place.
REVISION: 04/26/13
Henry Company 999 N. Sepulveda, Ste 800, El Segundo CA 90245-2754
Technical Services- Phone (800) 486-1278 – Email: techservices@henry.com
www.henry.com
Blueskin SA Self-Adhesive Air/Vapor Barrier Membrane
Limited Warranty
We, the manufacturer, warranty only that this product is free of defects, since many factors which affect the results obtained from this
product - such as weather, workmanship, equipment utilized and prior condition of the substrate - are all beyond our control. We will
replace at no charge any product proved to be defective within 12 months of purchase, provided it has been applied in accordance with
our written directions for uses we recommended as suitable for this product. Proof of purchase must be provided. DISCLAIMER OF
WARRANTIES: The Limited Warranty is IN LIEU OF any other warranties express or implied including but not limited to any implied
warranty of MERCHANTABILITY or fitness for a particular purpose, and we, the manufacturer, shall have no further liability of any kind
including liability for consequential or incidental damages resulting from any defects or any delays caused by replacement or otherwise.
STATEMENT OF RESPONSIBILITY
The technical and application information herein is based on the present state of our best scientific and practical knowledge. As the
information herein is of a general nature, no assumption can be made as to a product’s suitability for a particular use or application and
no warranty as to its accuracy, reliability or completeness either expressed or implied is given other than those required by law. The
user is responsible for checking the suitability of products for their intended use. Henry Company data sheets are updated on a regular
basis; it is the user’s responsibility to obtain and to confirm the most recent version. Information contained in this data sheet may
change without notice.
Henry Company, 999 N. Sepulveda, Ste. 800 El Segundo CA 90245 REV: 04/24/14
Tel: 800-486-1278 Email: techservices@henry.com
www.henry.com
TECHNICAL DATA SHEET
FOILSKIN
Self-Adhesive Weather Barrier Membrane
Physical Properties
-Color
-Thickness
-Application Temp
-Service Temp
-Elongation
(ASTM D412-modified)
-Tensile Strength Membrane
(ASTM D412- modified)
-Tensile Strength (Foil)
(ASTM C1136)
Mold Resistance
(ASTM C665)
Aluminum
40 mils (1.0 mm)
Minimum 20F (-7°C)
Minus -40F to 140F
40% minimum
900 psi (6.2 mPa)
2812 psi (19.4 mPa)
1875 psi (12.9 mPa)
No growth
-Minimum Puncture
Resistance – Membrane
(ASTM E154)
-Low Temperature Flexibility
@ -22F
(CGSB 37-GP-56M)
-Water Vapor Permeance
(ASTM E96)
-Lap Peel Strength @ 40F
(ASTM D903 180 bend)
40 lbf
(178 N)
Pass
2.8 ng/Pa.s.m²
(0.05 perms)
(15 lbs/ inch)
2600 N/m width
Packaging
-Thickness
-Roll length
-Roll width
-Gross Coverage
40 mils
33.3’
36”
100 sq. ft.
-Top Surface
-Bottom Surface
Foil Scrim
Siliconized Release Paper
Description
FOILSKIN® is a self-adhering membrane consisting of an SBS rubberized asphalt compound, integrally laminated
to a glass scrim reinforced aluminum foil. The membrane is specifically designed to be self-adhered to a prepared
substrate, providing a weather barrier.
Features
SBS modified membrane, flexible at low temperatures
Impermeable to air, moisture vapor and water
No flame or adhesive required for installation
Thickness controlled at point of manufacture
Excellent adhesion to prepared insulation substrates
Membrane is self-sealing when penetrated with self-tapping screws
Self-adhesive membrane bond strengthens over time
Does not promote mould growth
Ultra-violet light resistant
Uses
FOILSKIN® is designed for use as a transition membrane with Air-Bloc 33 Air Barrier System. See Air-Bloc 33
Guide Specification.
Storage
Store FOILSKIN® rolls on end, on original pallets or elevated platform. Protect unused portion of membrane by
storing in original box to maintain self-adhesive quality. Protect from weather elements or store in an enclosed
area not subject to heat over 120F. Double stacked pallets are not recommended. If double stacking is
necessary, use a plywood sheet to distribute the load.
Henry Company, 999 N. Sepulveda, Ste. 800 El Segundo CA 90245 REV: 04/24/14
Tel: 800-486-1278 Email: techservices@henry.com
www.henry.com
FOILSKIN® Self-Adhesive Weather Barrier Membrane
Limitations
FOILSKIN® is not to be used in direct contact with flexible/highly plasticized PVC/vinyl membranes or gaskets.
Some sealants may discolor if in contact with the asphalt compound or may soften the asphalt compound. Contact
sealant manufacturer for more information.
Surface Preparation
Acceptable substrates are precast concrete, cast-in place concrete, concrete block, primed steel, aluminum mill
finish, anodized aluminum, galvanized metal, gypsum board including Dens Glass Gold. All surfaces to receive
Foilskin must be clean of oil, dust and excess mortar. Strike masonry joints flush. Concrete surfaces must be
smooth and without large voids, spalled areas or sharp protrusions. Concrete must be cured a minimum of 14
days and must be dry before Foilskin® is applied. Where curing compounds are used, they must be clear resin
based, without oil, wax or pigments.
All surfaces to receive Foilskin® require an application of Blueskin® Primer applied by lambs wool roller or
brush at the rate of 85 to 250 sq. ft./gallon depending on porosity and texture of surface and allowed to dry for 30
minutes before Foilskin® is applied. Ensure that all surfaces receive Foilskin® in the same day. Alternatively,
apply Aquatac™ Primer by roller at a rate up to 500 sq. ft/gallon. Allow to dry to a tacky film.
Application
Refer to Air-Bloc 33 Guide Specification and details for further application information. Foilskin® must be
lapped a minimum of 2” on both sides and end laps. Position membrane for alignment, remove protective film and
press firmly in place. When membrane is entirely in place, roll membrane including seams with a counter top roller
to ensure full contact. When using membrane with brick ties, position membrane, press in place and cut for ties or
projections. Seal around any openings and at leading edge at the end of the days work with Air-Bloc 33.
Membrane applied to the underside of the substrate (i.e. ceilings) requires mechanical fastening through treated
wood, galvanized metal strapping, or have insulation mechanically fastened. Fastening must take place
immediately after installation of membrane. Space strapping on 18” centers, running perpendicular to the side
laps.
Detail work must be carefully carried out to ensure continuous air tightness of the membrane. It is recommended
that mechanical attachment be made to all window and doorframes, or a properly designed sealant joint be
provided.
Caution
FOILSKIN® is highly reflective to sunlight. It is strongly recommended to use sunglasses to prevent eye damage
when working with the membrane.
Limited Warranty
We, the manufacturer, warranty only that this product is free of defects, since many factors which affect the results obtaine d from
this product - such as weather, workmanship, equipment utilized and prior condition of the substrate - are all beyond our control.
We will replace at no charge any product proved to be defective within 12 months of purchase, provided it has been applied in
accordance with our written directions for uses we recommended as suitable for this product. Proof of purchase must be provided.
DISCLAIMER OF WARRANTIES: The Limited Warranty is IN LIEU OF any other warranties express or implied including but not
limited to any implied warranty of MERCHANTABILITY or fitness for a particular purpose, and we, the manufacturer, shall have no
further liability of any kind including liability for consequential or incidental damages resulting from any defects or any delays caused
by replacement or otherwise. <>
Northshore, please clarify FIP
insulation
by Northshore
Vertical support is
responsibility of Northshore
where panel ends do not land
on stud.
NBBJ, please confirm 'Vertical
Support' must conform to
074219 2.5 A Misc Metal
Subframing
NBBJ: CONFIRMED, DETAIL BELOW OR DETAIL
3/KIP601 AS APPROPRIATE TO SUPPORT
PANEL EDGES & TRANSFER LOADS PER
MANUFACTURER'S RECOMMENDATIONS.
36"
KS36KP
EXTERIOR FACE
INTERIOR FACE
3"
KIP 101
SWEDISH EDMONDS
AMBULATORY CARE CENTER
EDMONDS, WASHINGTON
a. Non-exposed sealant shall be field applied gun grade non-skinning butyl.
b. Exposed sealant shall be field applied gun grade urethane or silicone sealant.
(Not By KINGSPAN INSULATED PANELS)
c. KINGSPAN INSULATED PANELS is not responsible for field installed vapor seal at joints and junctures.
d. KINGSPAN INSULATED PANELS is not responsible for vapor leaks caused by penetration through
the panels.
a. All trim shall be fabricated from G90 or AZ50 in gauge and finish to match
panel face.
b. All trim is fastened at 12" o.c. unless otherwise noted in the details.
a.Holes in panels for other trades to be cut, sealed and flashed by the trade concerned unless
otherwise noted on these drawings.
b. Openings which would reduce the structural strength of the panel are to be adequately reinforced by
others.
a.The face of all steel must be free of bolt and rivet heads, built up welds or other obstruction which
might interfere with bearing of panels on girts or purlins.
b. Girts for support of panels must extend to outer extremities of elevations and across face of columns
to which panels are applied.
c. All panels supports are to be true and plumb prior to erecting panels. Recommended wall tolerance
is 14" in any 20' direction. Recommend roof tolerance is 0" outward, 12" inward from plane.
The following specifications appear on shop drawings prepared by KINGSPAN INSULATED PANELS.
They are intended to be a guide for minimum acceptable installation procedures and to indicate the
quantity, size and materials specification of products furnished by KINGSPAN INSULATED PANELS, for
the described project. They should not be used to replace or supplant specifications or notes on structural
drawings. Materials shown on these drawings and specifications have been approved by KINGSPAN
INSULATED PANELS for the purpose shown.
Exercise care to maintain uniform side joints on all panels at each elevation.
GENERAL NOTES:
SEALANTS:
TRIM:
WORK OF OTHER TRADES:
SUPPORTING STEEL AND GIRT SYSTEMS:
MODULE RETENTION:
FIELD-CUT PANELS:
a.Field cutting shall be performed in accordance with current Kingspan installation guides.
b.Field-cut panels where required at openings as shown on drawings. Cut edges are to be covered with trim.
c.Field-cut panels to slope at endwalls.
d.Some field cutting may be required.
TOUCH UP:
Use matching color touch up on material where damage consists of small chips, abrasions and field cut
edges. Touch up paint may be obtained by contacting Kingspan customer service. For larger area paint
repairs, consult the Kingspan Maintenance Manual for instructions. Each panel shall be covered until just
prior to erection. Care should be taken not to allow panel facings to come in contact with dirt, oil, grease,
standing water or any other material which could stain exposed surfaces. Carefully follow storage and
handling instructions included with shipping documents.
ON-SITE STORAGE:
Panels and accessories are to be adequately protected from traffic and weather to ensure against
physical damage or discoloration. Each panel shall be covered until just prior to erection. Care should be
taken not to allow panel facings to come in contact with dirt, oil, grease, standing water or any other
material which could stain exposed surfaces. Carefully follow storage and handling instructions included
with shipping documents.
SHEET INDEX
PAGE #DESCRIPTION
GENERAL INFORMATION, CALCULATIONS
FLOOR PLANS
KIP 101-102
KIP 201-202
LEGEND:
ABBREVIATIONS:
NOT ALL ABBREVIATIONS MAY BE USED ON THIS PROJECT
AFF
B.O.P.
BLDG.
CBC
CMU
F.F.
F.O.
GA.
GALV.
HORIZ.
IBC
NTS
O/O
PPH
SIM.
T.O.
T.O.P.
T.O.S.
TYP.
UBC
URE
W/
W/O
WSHR
SS
ABOVE FINISH FLOOR
BOTTOM OF PANEL
BUILDING
CALIFORNIA BUILDING CODE
CONCRETE MASONRY UNIT
FINISH FLOOR
FRAMED OPENING
GAUGE
GALVANIZED
HORIZONTAL
INTERNATIONAL BUILDING CODE
NOT TO SCALE
ON CENTER
OUT TO OUT
PHILIPS PANHEAD
SIMILAR
TOP OF
TOP OF PANEL
TOP OF STEEL
TYPICAL
UNIFORM BUILDING CODE
URETHANE
WITH
WITH OUT
WASHER
STANDING SEAM
O.C. OR O/C
DISCLAIMER:CUSTOMER REVIEW CHECKLIST:
Panel Information:
Ƒ Panel type and thickness
Ƒ Gauge and color of the exterior/interior skins
Ƒ ,IFRORULV³7REHGHWHUPLQHG´SOHDVHPDUNXSWKHGUDZLQJVZLWKWKHFKRVHQFRORUDQGFRQWDFW
your project coordinator to confirm the color selection
Floor Plans:
Ƒ Grid lines on the plans are correct
Ƒ Dimensions shown on the floor plan are correct with the latest structural/steel drawings
Ƒ Floor plans are representative of where Kingspan materials are to be provided
Ƒ If there are panel areas missing or not clearly shown, please mark up the drawings and
contact your project coordinator to review
Roof Plans: (If applicable)
Ƒ Roof dimensions are accurate
Ƒ Roof panel lengths are correct with the latest structural/steel drawings
Ƒ Endlaps (if present) are lined up with a roof purlin
Ƒ Overhangs (if present) are properly shown
Ƒ Canopy areas (if present) are properly shown
Ƒ If there are missing panels, overlaps needed that are not shown, or wrong dimensions
please mark up the drawings and contact your project coordinator
Elevations:
Ƒ Elevation tags show the correct location of the bottom of panel and top of panel/parapet/steel
Ƒ Framed opening sizes, locations, and quantities are correct
Ƒ Wall length dimensions are correct and match the floor plan
Ƒ Wall panel lengths are correct at each elevation shown
Ƒ Detail called out corresponds to the correct condition at that location
Ƒ Quantity and length of panels called out in panel lists correspond with that shown for each elevation
Ƒ If multiple panel types, verify that the proper panel types are being used in the proper location
Ƒ If panel areas are missing or not clearly shown, please identify on the drawings and contact your
project coordinator to review
Details:
Please review each detail shown thoroughly, with special attention to the following:
Ƒ Base condition(s) correct (flush mount or overhung?)
Ƒ Slab edge shown is correct, matches concrete condition (squared off or keyway?)
Ƒ Window details and flashings drawn correctly
Ƒ Overhead door details and flashings drawn correctly
Ƒ Trims necessary for proper installation shown in details (special attention should be paid to those
PDUNHG³1RWE\.LQJVSDQ´
Ƒ Location and type of structural members shown in details reflect actual structural members present
QRWHSOHDVHLQGLFDWHRQWKHGUDZLQJVLIWKHUHDUHDQ\ORFDWLRQVXWLOL]LQJVWHHOWKLFNHUWKDQó´VRWKDW
proper fasteners may be designated)
Ƒ If any detail conditions are omitted or are incorrect, please clearly identify on the drawings
Trims:
Ƒ Trims to be provided as shown
Ƒ Gauge and color of each trim piece is correctly identified
Ƒ Shapes and dimensions of each trim are correct
Ƒ If a different trim shape/dimension or color is desired, please mark up the drawings as needed
AFTER COMPLETING THIS CHECKLIST, PLEASE CHECK THE APPROPRIATE BOX LOCATED IN
7+(³)25$33529$/´6(&7,212)7+(7,7/(%/2&.7+(16,*1$1'5(78517+(
DRAWINGS TO YOUR KINGSPAN PROJECT COORDINATOR.
This checklist is provided as a guide when reviewing Kingspan shop drawings. Please take a
moment to verify that the following information presented in these drawings is correct:
Wall Sections:
Ƒ Wall construction/materials/panel thicknesses are correct
Ƒ Elevations of support members are correct
Ƒ Wall panel lengths are correct
KIP 401-407 WALL ELEVATIONS
KIP 601-604 DETAILS
A
2
GRID LINE DESTINATION
ELEVATION
DETAIL DESTINATION
ELEVATION VIEW
2 GRID LINE DESTINATION
2
CROSS SECTION
2
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
AFG ABOVE FINISH GRADE
B.F.F.BELOW FINISH FLOOR
Ƒ APPROVED AS SUBMITTED
Ƒ APPROVED AS NOTED
Ƒ REVISE / RESUBMIT
These Approval Drawings are submitted for the above referenced project. Please review, sign, and return the Drawings marked either :
"Approved as Submitted" (if there are no corrections),
"Approved as noted" (with correction(s) clearly noted on the returned Drawing set), or
"Revise / Resubmit" (with correction(s) clearly noted on the returned Drawing set).
All dimensions, details and trims require approval/verification.
All "clouded areas" must be reviewed and addressed to the satisfaction of Kingspan, before materials will be released for Fabrication and/or
Production Drawings will be issued.
Approval of the Kingspan Drawings and panel analysis indicates that Kingspan has correctly interpreted the project requirements, and the
designs thereof. This approval constitutes the acceptance of Kingspan dimensions, layouts, materials, and designs unless clearly noted
otherwise.
Kingspan is not responsible for checking the material and/or design compatibility of components that are not supplied by Kingspan.
APPROVAL SIGNATURE DATE:
PRINTED NAME & COMPANY OF SIGNATURE DATE:
TH
E
S
E
D
R
A
W
I
N
G
A
R
E
I
S
S
U
E
D
F
O
R
KI
N
G
S
P
A
N
P
R
O
D
U
C
T
AP
P
R
O
V
A
L
/
V
E
R
I
F
I
C
A
T
I
O
N
O
N
L
Y
A
N
D
SH
O
U
L
D
N
O
T
B
E
U
S
E
D
F
O
R
IN
S
T
A
L
L
A
T
I
O
N
P
U
R
P
O
S
E
S
-
"
F
O
R
PR
O
D
U
C
T
I
O
N
"
D
R
A
W
I
N
G
S
S
H
A
L
L
B
E
IS
S
U
E
D
A
F
T
E
R
A
P
P
R
O
V
E
D
D
R
A
W
I
N
G
S
HA
V
E
B
E
E
N
R
E
C
I
E
V
E
D
A
N
D
P
R
O
C
E
S
S
E
D
KIP 701-702 TRIMS
Customer to verify that the provided steel and/or architectural drawings upon which the Panel layout
and designs are based, are correct and accurately reflect the conditions necessary for design of all
materials supplied by KINGSPAN. Customer must also verify that the project field conditions are
representative of the drawings submitted, OR that any and all necessary revised conditions that may
impact design, have been submitted to and confirmed by KINGSPAN, prior to the release of
KINGSPAN Panel drawings or calculations.
KINGSPAN is not responsible or liable for incorrect Panel lengths as a result of changes made after
signed approved shop drawings are returned.
Drawings furnished by KINGSPAN show Panel layouts, wall elevations, and fastening details only;
they do not replace structural drawings. It is the project engineers or project architect's responsibility
to determine if allowable Panel and fastener loads meet the project design loads.
KINGSPAN is only responsible for showing items that are furnished by KINGSPAN. Reference
dimensions shown on these drawings have been taken from steel / architectural drawings provided
by the customer, and have not been independently verified by KINGSPAN.
Items not included in KINGSPAN material bid package may be shown in the drawings / details for
informational purposes only. KINGSPAN will supply only those items specifically included in the
Order Acknowledgement. It is the customer's (or the authorized agent's) responsibility to verify
KINGSPAN'S scope.
Optional engineering seal provided by KINGSPAN on these drawings indicates Panel spans and
connections have been verified and approved for use as drawn. This approval pertains solely to the
materials being supplied by KINGSPAN , and does NOT apply to the structural supports or any other
components which may be shown on the drawings (for clarification purposes only). These items must
be reviewed and approved by the project engineer of record.
WALL PANEL CONFIGURATION:
3"
36"
Urethane
EXTERIOR FACE
KS36KP
Coverage
Profile
Material
Texture
Gauge
Finish
Color
Core Thickness
Core Material
Panel Type
AZ50
Shadowline
MP
26
Stucco Embossed
INTERIOR FACE
MP
26
AZ50
Stucco Embossed
Shadowline
Imperial White Imperial White
KIP 501 SOFFIT PLAN
3/31/2015 3:15:27 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
KIP 102
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
3/31/2015 3:15:29 PM
363'-0"
1
N M L K J H G F E D C B A
2
3
4
4.8
5
XA
YA
1'
13
2
'
-
0
"
1
4
3
1
1/16" = 1'-0"
LEVEL ONE FLOOR PLAN
/
2
32 4
1
2
5
6
KIP 201
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
3/31/2015 3:15:35 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
1
L K J H G F E D C B A
2
3
4
4.8
5
XA
YA
X12
X10
X9
X7
X6
X5
X4
X7.4
X8
10
1/16" = 1'-0"
LEVEL TWO FLOOR PLAN
/
303'-6"
13
2
'
-
0
"
1
3
2
32 4
1
2
12
9
8
7
4
13
11
EW2
EW1
KIP 202
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
3/31/2015 3:15:36 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
1
PANELS QUANTITY -
-
GRID LINE 1'
1/8" = 1'-0"
128'-4" O/O PANEL
10
4
8
2
TYP
T.O.P.
15'-0"
LEVEL 1
0'-0"
69'-9" O/O PANEL
3 TYP
28
28
B.O.P.
0'-6"
T.O.P.
24'-0"
14
3'-3" O/O PANEL
16
7
23'-3"23'-3"23'-3"32'-1"32'-1"32'-1"32'-1"
3
PANELS QUANTITY -
-
GRID LINE A
1/8" = 1'-0"
11
4
LEVEL 1
0'-0"
B.O.P.
0'-6"
T.O.P.
56'-0"
126'-101 4" O/O PANEL
28
10
25'-512"25'-512"25'-512"25'-512"25'-01 4"
8'-212"
15
11
2
TYP
3 TYP
28
21
SIM
KIP 401
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
ALL DIMENSIONS ARE
O/O OF PANELS
REQUIRE VERIFICATION--NOT BY KINGSPAN.
ALL DIMENSIONS AND PANEL LENGTHSNOTE:
22
24
23 23
@ STOREFRONT
25
26 26
@ DOOR
3/31/2015 3:15:37 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
2
PANELS QUANTITY -
-
GRID LINE 1
1/8" = 1'-0"
166'-103 4" O/O PANEL
4
LEVEL 1
0'-0"
28
B.O.P.
0'-6"
T.O.P.
41'-0"
16
10
10
9
31'-73 4"31'-73 4"27'-23 4"25'-512"25'-512"25'-512"
3 TYP3TYP
10
76'-43 4" O/O PANEL
28
10
25'-512"25'-53 4"25'-512"
2 GRID LINE 1 - CONTINUED
1/8" = 1'-0"
LEVEL 1
0'-0"
B.O.P.
0'-6"
T.O.P.
56'-0"
2
TYP
KIP 402
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
ALL DIMENSIONS ARE
O/O OF PANELS
REQUIRE VERIFICATION--NOT BY KINGSPAN.
ALL DIMENSIONS AND PANEL LENGTHSNOTE:
22
24
23 23
@ STOREFRONT
25
26 26
@ DOOR
3/31/2015 3:15:38 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
4
PANELS QUANTITY -
-
GRID LINE XA
1/8" = 1'-0"
4
LEVEL 1
0'-0"
B.O.P.
0'-6"
11 23
32
84'-714" O/O PANEL
28'-23 8"
T.O.P.
41'-0"
LEVEL 2
22'-0"
B.O.P.
31'-0"
T.O.P.
56'-0"
76'-7" O/O PANEL
20'-218"
45'-6" O/O PANEL
43'-514" O/O PANEL
21'-85 8"21'-85 8"28'-23 8"28'-212"
22
28'-212"28'-23 8"22'-9"22'-9"
28
28
11
12
13
20
4
2
TYP
3 TYP
21
28
11'-47 8"SIM
5
PANELS QUANTITY -
-
ELEVATION 5
1/8" = 1'-0"
4
LEVEL 1
0'-0"
B.O.P.
0'-6"
16 10
32
18'-83 8" O/O PANEL
6
PANELS QUANTITY -
-
ELEVATION 6
1/8" = 1'-0"
4
LEVEL 1
0'-0"
B.O.P.
0'-6"
10 20
32
74'-43 4" O/O PANEL
T.O.P.
11'-0"
T.O.P.
11'-0"
18'-53 4"32'-0"23'-11"
22
2
TYP
23 23
KIP 403
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
ALL DIMENSIONS ARE
O/O OF PANELS
REQUIRE VERIFICATION--NOT BY KINGSPAN.
ALL DIMENSIONS AND PANEL LENGTHSNOTE:
22
24
23 23
@ STOREFRONT
25
26 26
@ DOOR
3/31/2015 3:15:39 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
7
PANELS QUANTITY -
-
GRID LINE XA
1/8" = 1'-0"
B.O.P.
31'-0"
T.O.P.
41'-0"
145'-012" O/O PANEL
21'-71 4"25'-512"25'-512"25'-512"25'-512"
12
28
4
21'-71 4"
17
3 TYP
8
PANELS QUANTITY -
-
GRID LINE X8 - CONNECTOR
1/8" = 1'-0"
B.O.P.
19'-0"
PENTHOUSE
38'-0"
66'-712" O/O PANEL
25'-512"25'-512"
17
28
15'-812"
LEVEL 2
22'-0"
6
B.O.P.
31'-0"
T.O.P.
25'-0"
31
2'-5"
9
PANELS QUANTITY -
-
GRID LINE X7.4 - CONNECTOR
1/8" = 1'-0"
B.O.P.
19'-0"
T.O.P.
41'-0"
97'-10" O/O PANEL
25'-512"25'-512"
18
28
16'-51 4"
LEVEL 2
22'-0"
6
PENTHOUSE
38'-0"
31
2'-5"
30'-53 4"
6'-11"
B.O.P.
23'-6"
5
2
TYP
2
TYP
3 TYP 3 TYP
SIM SIM
KIP 404
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
ALL DIMENSIONS ARE
O/O OF PANELS
REQUIRE VERIFICATION--NOT BY KINGSPAN.
ALL DIMENSIONS AND PANEL LENGTHSNOTE:
22
24
23 23
@ STOREFRONT
25
26 26
@ DOOR
3/31/2015 3:15:40 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
10
PANELS QUANTITY -
-
GRID LINE J
1/8" = 1'-0"
T.O.P.
41'-0"
108'-1118" O/O PANEL
25'-512"25'-512"
10
28
32'-65 8"
LEVEL 2
22'-0"
18
PENTHOUSE
38'-0"
5
25'-512"
B.O.P.
23'-6"
2
TYP
2
TYP
3 TYP
11
PANELS QUANTITY -
-
GRID LINE YA
1/8" = 1'-0"
145'-112" O/O PANEL
24'-21 4"24'-214"
10
28
24'-21 4"
LEVEL 2
22'-0"
10
5
24'-214"
T.O.P.
24'-0"
B.O.P.
15'-0"
16
5 5
14'-27 8" O/O PANEL
10
28
32
24'-21 4"24'-21 4"
18'-113 4"10'-27 8"
26'-812"
5'-03 8"
2'-0" O/O PANEL
19 19
2
TYP
3 TYP
28
11
PANELS QUANTITY -
-
GRID LINE YA - CONTINUED
1/8" = 1'-0"
59'-312" O/O PANEL
29'-73 4"
14
28
LEVEL 2
22'-0"
5
29'-73 4"
T.O.P.
24'-0"
B.O.P.
15'-0"
1610
28
5 2
TYP
3
TYP
KIP 405
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
ALL DIMENSIONS ARE
O/O OF PANELS
REQUIRE VERIFICATION--NOT BY KINGSPAN.
ALL DIMENSIONS AND PANEL LENGTHSNOTE:
22
24
23 23
@ STOREFRONT
25
26 26
@ DOOR
3/31/2015 3:15:41 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
12
PANELS QUANTITY -
-
PENTHOUSE
1/8" = 1'-0"
13
4
LEVEL 1
0'-0"
T.O.P.
56'-0"
132'-13 4" O/O PANEL
28
10
25'-512"25'-512"30'-9"25'-512"25'-014"
8'-212"
PENTHOUSE
38'-0"
2
TYP
3 TYP
EW2
PANELS QUANTITY -
-
EXHAUST WELL
1/8" = 1'-0"
16
4
T.O.P.
56'-0"
59'-212" O/O PANEL
28
19
29'-71 4"29'-714"
PENTHOUSE
38'-0"
EW1
PANELS QUANTITY -
-
EXHAUST WELL
1/8" = 1'-0"
19
4
T.O.P.
56'-0"
22'-53 4" O/O PANEL
28
16
PENTHOUSE
38'-0"
KIP 406
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
ALL DIMENSIONS ARE
O/O OF PANELS
REQUIRE VERIFICATION--NOT BY KINGSPAN.
ALL DIMENSIONS AND PANEL LENGTHSNOTE:
22
24
23 23
@ STOREFRONT
25
26 26
@ DOOR
3/31/2015 3:15:43 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
13
PANELS QUANTITY -
-
CANOPY
1/8" = 1'-0"
LEVEL 1
0'-0"
250'-1112" O/O PANEL
LEVEL 2
22'-0"
33'-0"34'-5"
28'-5"
19'-6"19'-6"19'-6"
28
15
2
TYP
3 TYP
250'-1112" O/O PANEL
13'-814"
19'-6"19'-6"19'-6"
33'-21 4"
19'-6"19'-6"27'-612"
4'-0"
B.O.P.
13'-0"
10
31
31
10
13
PANELS QUANTITY -
-
CANOPY - CONTINUED
1/8" = 1'-0"
31
14'-23 4"
32
1027
SIM
SIM
KIP 407
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
ALL DIMENSIONS ARE
O/O OF PANELS
REQUIRE VERIFICATION--NOT BY KINGSPAN.
ALL DIMENSIONS AND PANEL LENGTHSNOTE:
3/31/2015 3:15:44 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
4.8
5
XA
X12
X10
X9
X7
X7.4
X8
YA
1/16" = 1'-0"
SOFFIT PLAN
13
'
-
2
"
12
'
-
5
"
11
'
-
8
"
10
'
-
1
1
"
10
'
-
2
"
9'-
5
"
8'-
8
"
7'-
1
1
"
7'-
2
"
6'-
5
"
5'-
8
"
4'-
1
1
"
4'-
2
"
3'-
5
"
3'-
0
"
14
'
-
8
"
13
'
-
1
1
"
15
'
-
5
"
16
'
-
2
"
16
'
-
1
1
"
17
'
-
8
"
18
'
-
5
"
19
'
-
2
"
19
'
-
1
1
"
20
'
-
8
"
21
'
-
5
"
22
'
-
2
"
22
'
-
9
"
20
'
-
0
"
10
'
-
9
"
6'-
6
"
7'-
6
"
8'-
6
"
9'-
6
"
10
'
-
5
"
11
'
-
5
"
13
'
-
4
"
12
'
-
5
"
15
'
-
4
"
14
'
-
4
"
16
'
-
4
"
17
'
-
3
"
17
'
-
9
"
19
'
-
2
"
31
31
32
3232
32
32
18
'
-
3
"
19
'
-
3
"
20
'
-
2
"
21
'
-
2
"
22
'
-
2
"
23
'
-
1
"
24
'
-
1
"
25
'
-
1
"
26
'
-
1
"
27
'
-
0
"
28
'
-
0
"
28
'
-
2
"
27
'
-
1
0
"
27
'
-
5
"
27
'
-
0
"
26
'
-
7
"
26
'
-
2
"
25
'
-
9
"
25
'
-
4
"
24
'
-
1
1
"
24
'
-
6
"
24
'
-
0
"
23
'
-
7
"
24
'
-
6
"
22
'
-
9
"
22
'
-
4
"
21
'
-
1
1
"
21
'
-
6
"
21
'
-
1
"
20
'
-
8
"
20
'
-
3
"
19
'
-
1
0
"
19
'
-
5
"
19
'
-
0
"
18
'
-
7
"
18
'
-
2
"
17
'
-
9
"
17
'
-
4
"
16
'
-
1
1
"
16
'
-
5
"
71'-1
1
"
247'-
0
1
/
2
"
31
32
32
SIM
SIM
14
'
-
8
3 8"
KIP 501
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
ALL DIMENSIONS ARE
O/O OF PANELS
REQUIRE VERIFICATION--NOT BY KINGSPAN.
ALL DIMENSIONS AND PANEL LENGTHSNOTE:
3/31/2015 3:15:45 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
NBBJ: REQUESTED DETAIL @ CURTAINWALL
HEAD NOT PROVIDED. REFERENCE 13 &
14/A8.04. CONTINUITY OF WEATHER, AIR &
THERMAL BARRIER PAST HEAD SUPPORTING
CHANNEL TO CURTAINWALL HEAD SHALL BE
MAINTAINED. GC TO VERIFY & COORDINATE.
2
7
3
5 6
8 9
4
SECTION VIEW
PANEL JOINT SCALE: N.T.S.
PLAN VIEW
INTERMEDIATE SUPPORT SCALE: N.T.S.1 VERTICAL JOINT
PLAN VIEW
SCALE: N.T.S.
SECTION VIEW
BASE SCALE: N.T.S.
FIELD CUT PANEL AS REQ'D
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT
AT PANEL JOINTS
&217,18286.$55,(55$,/
(1) 14" - 14 x 4" TEK 3
FASTENERS w/ WASHER
AT EVERY OTHER STUD
6(7.$55,(55$,/,1%87</
SEALANT AT FASTENER
LOCATIONS
FE
M
A
L
E
J
O
I
N
T
MA
L
E
J
O
I
N
T
WA
L
L
P
A
N
E
L
I
N
S
T
A
L
L
A
T
I
O
N
D
I
R
E
C
T
I
O
N
VERTICAL SUPPORT
(NOT BY KINGSPAN)
METAL PANEL
(NOT BY KINGSPAN)
MP-1 CONTINUOUS MENDING
PLATE w/ POP RIVETS @ 12" O/C
ATTACHED TO STUD FRAMING
PRIOR TO PANEL INSTALLATION
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
FILL GAPS 14" OR LARGER
WITH F.I.P. INSULATION
(NOT BY KINGSPAN)
VERTICAL SUPPORT
(NOT BY KINGSPAN)
&217,18286.$55,(55$,/
6(7.$55,(55$,/,1%87</
SEALANT AT FASTENER
LOCATIONS
5" MIN.
5" MIN.
OPTIONAL FRAMING
TRIPLE STUD
(2) 14" - 14 x 4" TEK 3
FASTENERS w/o WASHER
METAL PANEL SYSTEM
(NOT BY KINGSPAN)
&217,1286.$55,(55$,/
SINGLE SKIN PANEL
(NOT BY KINGSPAN)
(2) 1 4" - 14 x 4" TEK 3
FASTENERS w/ WASHER
AT EVERY OTHER STUD
VERTICAL SUPPORT
AT 16" O.C.
(NOT BY KINGSPAN)
6(7.$55,(55$,/,1%87</
SEALANT AT FASTENER
LOCATIONS
METAL PANEL
(NOT BY KINGSPAN)
4" DP3 FASTENER
@ 12" O.C.
BUTYL SEALANT
METAL STUD FRMG
BY OTHERS
FLEXIBLE FLASHING
(NOT BY KINGSPAN)
SCALE: N.T.S.
SECTION VIEW
BASE @ ROOF
BUILT UP ROOF
(NOT BY KINGSPAN)
1 4" - 14 x 4" TEK 3 FASTENERS
w/ WASHER @ 12" O.C.
MEMBRANE FLASHING
(NOT BY KINGSPAN)
CONTINUOUS
BUTYL SEALANT
SECTION VIEW
BASE SCALE: N.T.S.
METAL PANEL
(NOT BY KINGSPAN)
BUTYL SEALANT
METAL STUD FRMG
BY OTHERS
FLEXIBLE FLASHING
(NOT BY KINGSPAN)
JC-1 "J" CLIP w/
1" DP3 @ 12" O.C.
w/ SEALANT IN BASE
FILL GAPS 14" OR LARGER
WITH F.I.P. INSULATION
(NOT BY KINGSPAN)
SCALE: N.T.S.
PLAN VIEW
PANEL @ EXPANSION JOINT
CT-3 CAP TRIM
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
METAL PANEL
(NOT BY KINGSPAN)
FASTENER
(NOT BY KINGSPAN)
SUB FRAMING AS REQUIRED
(NOT BY KINGSPAN)
EXPANSION JOINT
(NOT BY KINGSPAN)
(2) 1 4"-14 x 4" TEK 3 w/o
WASHER, PER SUPPORT
CT-3 CAP TRIM
VERTICAL SUPPORT
(NOT BY KINGSPAN)
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
METAL PANEL
(NOT BY KINGSPAN)
SUB FRAMING
(NOT BY KINGSPAN)
EXPANSION JOINT
(NOT BY KINGSPAN)
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
SCALE: N.T.S.
PLAN VIEW
PANEL @ EXPANSION JOINT SCALE: N.T.S.
PLAN VIEW
PANEL @ EXPANSION JOINT
(2) 14" - 14 x 4" TEK 3
FASTENERS w/o WASHER
METAL PANEL
(NOT BY KINGSPAN)
SUB FRAMING AS REQUIRED
(NOT BY KINGSPAN)
EXPANSION JOINT
(NOT BY KINGSPAN)
1 4" - 14 x 4" TEK 3
FASTENERS w/ WASHER
AT EVERY OTHER STUD (1) 14" - 14 x 4" TEK 3
FASTENERS w/ WASHER
AT EVERY OTHER STUD
&217,18286.$55,(55$,/
(2) 14" - 14 x 4" TEK 3
FASTENERS w/o WASHER
PER SUPPORT
KIP 601
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
3/31/2015 3:15:46 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
11
16
1210
14 15
17 18
13
SCALE: N.T.S.
PLAN VIEW
OUTSIDE CORNER
SCALE: N.T.S.
PLAN VIEW
INSIDE CORNER SCALE: N.T.S.
PLAN VIEW
INSIDE CORNER
(2) 14"-14 x 4" TEK 3 w/
WASHER, PER SUPPORT
OC-7 OUTSIDE TRIM
w/ #10 x 3 4" PPH @ 12" O.C.
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
METAL PANEL
(NOT BY KINGSPAN)
6(7.$55,(5&/,3,1
BUTYL SEALANT AT
FASTENER LOCATIONS
.$55,(55$,/
IC-7 INSIDE CORNER TRIM
w/ POP RIVETS @ 12" O.C.
(2) 1 4"-14 x 4" TEK 3 w/o
WASHER, PER SUPPORT
IC-1 INSIDE CORNER TRIM
VERTICAL SUPPORT
(NOT BY KINGSPAN)
FIELD MITER CUT
PANELS
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
METAL PANEL
(NOT BY KINGSPAN)
OC-1 OUTSIDE CORNER
w/ POP RIVETS @ 12" O.C.
F.I.P. INSULATION
AS REQUIRED
(BY OTHERS)
SUB FRAMING AS REQUIRED
(NOT BY KINGSPAN)
OUTSIDE CORNER
OUTSIDE CORNER
PLAN VIEW
SCALE: N.T.S.
IC-2 INSIDE CORNER TRIM
SCALE: N.T.S.OUTSIDE CORNER
PLAN VIEW
SCALE: N.T.S.
PLAN VIEW
SCALE: N.T.S.
PLAN VIEW
OUTSIDE CORNER
SUB FRAMING
(NOT BY KINGSPAN)
METAL PANEL
(NOT BY KINGSPAN)
(2) 14"-14 x 4" TEK 3 w/o
WASHER, PER SUPPORT
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
OC-2 OUTSIDE CORNER
w/ POP RIVETS @ 12" O.C.
KARRIER RAIL CONTINUOUS KARRIER RAIL
BUTYL SEALANT
BUTYL SEALANT
OC-3 OUTSIDE CORNER
w/ POP RIVETS @ 12" O.C.
METAL PANEL
(NOT BY KINGSPAN)
SUB FRAMING
(NOT BY KINGSPAN)
BUTYL SEALANT
(2) 14"-14 x 4" TEK 3 w/o
WASHER, PER SUPPORT
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
IC-3 INSIDE CORNER TRIM
SUB FRAMING
(NOT BY KINGSPAN)
METAL PANEL
(NOT BY KINGSPAN)
(2) 14"-14 x 4" TEK 3 w/o
WASHER, PER SUPPORT
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
IC-4 INSIDE CORNER TRIM
OC-4 OUTSIDE CORNER
w/ POP RIVETS @ 12" O.C.
KARRIER RAIL
BUTYL SEALANT
METAL PANEL
(NOT BY KINGSPAN)
SUB FRAMING AS REQUIRED
(NOT BY KINGSPAN)
(2) 14"-14 x 4" TEK 3 w/o
WASHER, PER SUPPORT
OC-5 OUTSIDE CORNER
w/ POP RIVETS @ 12" O.C.
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
IC-5 INSIDE CORNER TRIM
BUTYL SEALANT
KARRIER RAIL
OUTSIDE CORNER SCALE: N.T.S.
PLAN VIEW
SUB FRAMING
(NOT BY KINGSPAN)
METAL PANEL
(NOT BY KINGSPAN)(2) 1 4"-14 x 4" TEK 3 w/o
WASHER, PER SUPPORT
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
OC-6 OUTSIDE CORNER
w/ POP RIVETS @ 12" O.C.
IC-6 INSIDE CORNER TRIM
w/ #10 x 3 4" PPH @ 12" O.C.
KARRIER RAIL
BUTYL SEALANT
SCALE: N.T.S.
PLAN VIEW
INSIDE CORNER
METAL PANEL
(NOT BY KINGSPAN)
SUB FRAMING
(NOT BY KINGSPAN)
(2) 14"-14 x 4" TEK 3 w/o
WASHER, PER SUPPORT
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
IC-8 INSIDE CORNER TRIM
KARRIER RAIL
BUTYL SEALANT
OC-8 OUTSIDE CORNER
w/ POP RIVETS @ 12" O.C.
METAL PANEL
(NOT BY KINGSPAN)
SUB FRAMING
(NOT BY KINGSPAN)
OC-9 OUTSIDE CORNER
w/ #10 x 3 4" PPH @ 12" O.C.
KARRIER RAIL
BUTYL SEALANT
(2) 14"-14 x 4" TEK 3 w/o
WASHER, PER SUPPORT
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
IC-9 INSIDE CORNER TRIM
w/ POP RIVETS @ 12" O.C.
KIP 602
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
3/31/2015 3:15:48 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
20
25
2119
23 24
26 27
22
SCALE: N.T.S.
PLAN VIEW
INSIDE CORNER @ PERP. TO PANEL
(2) 1 4"-14 x 4" TEK 3 w/
WASHER, PER SUPPORT
CT-3 CAP TRIM
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
METAL PANEL
(NOT BY KINGSPAN)
6(7.$55,(5&/,3,1
BUTYL SEALANT AT
FASTENER LOCATIONS
.$55,(55$,/
BACKER ROD & SEALANT
(NOT BY KINGSPAN)
(2) 1 4"-14 x 4" TEK 3 w/
WASHER, PER SUPPORT
CT-3 CAP TRIM
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
METAL PANEL
(NOT BY KINGSPAN)
6(7.$55,(55$,/,1
BUTYL SEALANT AT
FASTENER LOCATIONS
.$55,(5&/,3
SUB FRAMING & FASTENER
(NOT BY KINGSPAN)
WINDOW SYSTEM
(NOT BY KINGSPAN)EXPOSED SEALANT
(NOT BY KINGSPAN)
FIELD CUT PANELS AS REQUIRED
FLASHING
(NOT BY KINGSPAN)
PANEL SYSTEM
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT
1 4" - 14 x 4" TEK 3 FASTENERS
w/ WASHER @ 12" O.C.
SUB FRAMING
(NOT BY KINGSPAN)
NOTE:
SEE ARCHITECTURAL DETAILS 1 & 4/A8.04
SCALE: N.T.S.
PLAN VIEW
INSIDE CORNER @ GLAZING
PANEL SYSTEM
(NOT BY KINGSPAN)
SUB FRAMING AS REQUIRED
(NOT BY KINGSPAN)
(2) 14"-14 x 4" TEK 3 w/o
WASHER, PER SUPPORT
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
IC-10 INSIDE CORNER TRIM
KARRIER RAIL
BUTYL SEALANT
OC-10 OUTSIDE CORNER
w/ POP RIVETS @ 12" O.C.
(2) 4" DP3 PER SUPPORT
SCALE: N.T.S.
PLAN VIEW
JAMBSCALE: N.T.S.
SECTION VIEW
HEAD SCALE: N.T.S.
SECTION VIEW
SILL
SCALE: N.T.S.
PLAN VIEW
DOOR JAMBSCALE: N.T.S.
SECTION VIEW
DOOR HEAD
NOTE:
SEE ARCHITECTURAL DETAILS 2 & 5/A8.04
NOTE:
SEE ARCHITECTURAL DETAILS 3 & 6 /A8.04
WINDOW SYSTEM
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
FLASHING
(NOT BY KINGSPAN)
PANEL SYSTEM
(NOT BY KINGSPAN)
14" - 14 x 4" TEK 3 FASTENERS
w/ WASHER @ 12" O.C.
SUB FRAMING
(NOT BY KINGSPAN)
FASTENER AS REQUIRED
ATTACHED TO STRUCTURAL MEMEBER
(NOT BY KINGSPAN)
WINDOW SYSTEM
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
FIELD CUT PANELS
AS REQUIRED
FLASHING
(NOT BY KINGSPAN)
PANEL SYSTEM
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT
14" - 14 x 4" TEK 3 FASTENERS
w/ WASHER @ 12" O.C.
SUB FRAMING
(NOT BY KINGSPAN)
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
DOOR FRAME
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
FIELD CUT PANELS AS REQUIRED
FLASHING
(NOT BY KINGSPAN)
PANEL SYSTEM
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT
1 4" - 14 x 4" TEK 3 FASTENERS
w/ WASHER @ 12" O.C.
SUB FRAMING
(NOT BY KINGSPAN)
NOTE:
SEE ARCHITECTURAL DETAILS 1, 2, & 5/A8.01
NOTE:
SEE ARCHITECTURAL DETAILS 2 & 5/A8.04
DOOR FRAME
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
FLASHING
(NOT BY KINGSPAN)
PANEL SYSTEM
(NOT BY KINGSPAN)
14" - 14 x 4" TEK 3 FASTENERS
w/ WASHER @ 12" O.C.
SUB FRAMING
(NOT BY KINGSPAN)
FASTENER AS REQUIRED
ATTACHED TO STRUCTURAL MEMEBER
(NOT BY KINGSPAN)
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
BUTT JOINT TO OTHER
PLAN VIEW
SCALE: N.T.S.
MP-1 CONTINUOUS MENDING
PLATE w/ POP RIVETS @ 12" O/C
ATTACHED TO STUD FRAMING
PRIOR TO PANEL INSTALLATION
CONTINUOUS BUTYL
SEALANT WITH MARRIAGE
BEAD TO HORIZONTAL
PANEL JOINT
VERTICAL SUPPORT
(NOT BY KINGSPAN)
.$55,(55$,/
6(7.$55,(5&/,3,1%87</
SEALANT AT FASTENER
LOCATIONS
5" MIN.
(2) 14" - 14 x 4" TEK 3
FASTENERS w/o WASHER
METAL PANEL SYSTEM
(NOT BY KINGSPAN)
SCALE: N.T.S.
PLAN VIEW
PANEL TO GLAZING
KARRIER RAIL
KIP 603
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
3/31/2015 3:15:49 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
29
34
3028
32 33
35 36
31 SECTION VIEW
SOFFIT TO WALL SCALE: 3" = 1'-0"
SECTION VIEW
FASCIA TO SOFFIT SCALE: 3" = 1'-0"
14" - 14 x 4" TEK 3
FASTENERS
w/ WASHER @ 12" O.C.
METAL PANEL
(NOT BY KINGSPAN)
SUB FRAMING
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT
SOFFIT PANEL
(NOT BY KINGSPAN)
SOFFIT PANEL
(NOT BY KINGSPAN)
BUTYL SEALANT
FASTENER AS REQUIRED
(NOT BY KINGSPAN)
PANEL SYSTEM
(NOT BY KINGSPAN)
SUB FRAMING
(NOT BY KINGSPAN)
SECTION VIEW
PARAPET SCALE: 3" = 1'-0"
PARAPET FRAMING & FLASHING
(NOT BY KINGSPAN)
14" - 14 x 4" TEK 3
FASTENERS
w/ WASHER @ 12" O.C.
METAL PANEL
(NOT BY KINGSPAN)
SUB FRAMING
(NOT BY KINGSPAN)
NOTE:
SEE ARCHITECTURAL DETAIL 4/A8.02
NOTE:
SEE ARCHITECTURAL DETAIL 11/A8.02
BUTYL SEALANT
FILL VOIDS w/ F.I.P.
FLEXIBLE FLASHING
(NOT BY KINGSPAN)
4" DP3 FASTENER
@ 12" O.C.
KIP 604
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
3/31/2015 3:15:51 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
MENDING PLATE
26 GA. IMPERIAL WHITE SE
MP-1
5
CT-3CAP TRIM
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 6.00
12
2
3
COLOR
12
OC-1OUTSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 5.00
12
1 2
2
2
COLOR
OC-2OUTSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 5.00
IC-2INSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 7.00
12 12
COLOR
BLANK WIDTH:6.00
IC-1INSIDE CORNER
26 GA. IMPERIAL WHITE SE
COLOR
12
12
3
3
BLANK WIDTH: 7.00
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
OC-3OUTSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 8.00
IC-3INSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 7.00
OC-4OUTSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 5.00
IC-4INSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 7.00
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
12
12
2
2
COLOR
3
3
12
12
COLOR
12
2
12
2
COLOR
12
12
3 3
COLOR
2
122
12
COLOR
12
12
3
3
COLOR
OC-5OUTSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 5.00
IC-5INSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 7.00
12
12
2
2
COLOR
12
3
3
12
COLOR
OC-6OUTSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 5.00
IC-6INSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 7.00
12
12
12
12 2
2
COLOR
3
3
COLOR
OC-7OUTSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 5.00
IC-7INSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 8.00
12
12
2
2
COLOR
12
12
412
212
COLOR
OC-8OUTSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 5.00
IC-8INSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 7.00
12
12 2
2 COLOR
12
123
3COLOR
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
FO
R
P
R
O
D
U
C
T
I
O
N
U
S
E
:
CH
K
BY
ST
R
E
T
C
H
O
U
T
OC-9OUTSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 7.00
OC-10OUTSIDE CORNER
26 GA. IMPERIAL WHITE SE
IC-9INSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 5.00
12
12
3
3
COLOR
12
2
12
2
COLOR
IC-10INSIDE CORNER
26 GA. IMPERIAL WHITE SE
BLANK WIDTH: 5.00
BLANK WIDTH: 7.00
12
12 2
2 COLOR
12
3
COLOR
3
12
PLEASE VERIFY
KIP 701
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
3/31/2015 3:15:52 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
26 GA. IMPERIAL WHITE
FLATSTOCK FS-1
(2) BEADS OF
BUTYL SEALANT
FIELD NOTCH
AS REQUIRED
TRIM END LAP
.$55,(55$,/
16 GA. GALV. (BARE)
"J" CLIP
18 GA. BARE
JC-1
KARRIER RAIL MUST BE 50ksi STEEL. 33ksi STEEL WILL NOT BE ALLOWED
KIP 702
DATE
DRAWN
SCALE
JOB No.
SHEET
JOB NAME
PL
03/04/15
AS NOTED
M15 25376
SWEDISH EDMONDS ACC
DR
A
F
T
S
M
A
N
:
CO
N
T
A
C
T
N
U
M
B
E
R
:
CO
N
T
A
C
T
N
A
M
E
:
SH
O
P
S
C
H
E
C
K
E
D
B
Y
:
JO
B
N
A
M
E
:
CU
S
T
O
M
E
R
N
A
M
E
:
JO
B
L
O
C
A
T
I
O
N
:
PR
O
J
E
C
T
C
O
O
R
D
I
N
A
T
O
R
:
BY
De
l
a
n
d
F
L
.
,
M
o
d
e
s
t
o
C
A
.
,
C
o
l
u
m
b
u
s
O
H
.
ww
w
.
k
i
n
g
s
p
a
n
p
a
n
e
l
s
.
u
s
Fa
x
:
(
2
0
9
)
5
3
1
-
9
0
5
5
,
T
e
l
:
(
2
0
9
)
5
3
1
9
0
9
1
R
RE
V
I
S
I
O
N
S
TH
E
S
E
S
H
O
P
D
R
A
W
I
N
G
S
W
E
R
E
C
R
E
A
T
E
D
U
S
I
N
G
TH
E
F
O
L
L
O
W
I
N
G
I
N
F
O
R
M
A
T
I
O
N
S
U
P
P
L
I
E
D
B
Y
CU
S
T
O
M
E
R
A
S
T
H
E
B
A
S
I
S
O
F
D
E
S
I
G
N
:
DA
T
E
:
PL
A
N
S
6/
1
0
/
1
4
NB
B
J
-
A
R
C
H
S
E
T
SHEET
Ƒ
AP
P
R
O
V
E
D
A
S
N
O
T
E
D
Ƒ
AP
P
R
O
V
E
D
A
S
S
U
B
M
I
T
T
E
D
Ƒ
RE
V
I
S
E
/
R
E
S
U
B
M
I
T
SI
G
N
A
T
U
R
E
:
DA
T
E
:
3/31/2015 3:15:54 PM
Kingspan drawings for reference of panel layout only.
Northshore drawings conforming to NBBJ comments per
returned submittal PAAN 0169-074219001-0 will take
presedence over information representied in these details.
NBBJ: PREVIOUSLY
REVIEWED INFORMATION
NOT REVIEWED W/
RE-SUBMITTAL
NBBJ: CONTINUOUS BUTYL SEALANT
PER MANUFACTURER'S STANDARD
DETAIL - OPTIONAL BEAD IN FORWARD
GROOVE RECOMMENDED (TYP)
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: GC NOTE -
COLD FORMED
METAL FRAMING
TO EDGE OF
SEISMIC JOINT
GAP
NBBJ: SEALANT BOTH
SIDES OF TRIM TO
MAINTAIN AIR BARRIER
CONTINUITY W/ STUD (TYP)
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: GC NOTE - FLEXI-FLASH
AS REQUIRED FOR AIR
BARRIER CONTINUITY TO
INNER SEAL (TYP)
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: NO VOID - CUT
PANEL ENDS TO
REQUIRED PROFILE
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: GC NOTE - FLEXI-FLASH
AS REQUIRED FOR AIR
BARRIER CONTINUITY TO
INNER SEAL (TYP)
NBBJ: GC NOTE - FLEXI-FLASH
AS REQUIRED FOR AIR
BARRIER CONTINUITY TO
INNER SEAL (TYP)
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: PANEL & FLASHING
SEALED TO UNDERSIDE OF
SILL PAN SIMILAR TO 10-DET
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: GC NOTE -
MAINTAIN CONTINUOUS
ROOF MEMBRANE SEAL
TO INSULATED METAL
PANEL SYSTEM
NBBJ: CONFIRM
WOOD NAILERS
PER RFI-187
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: PROVIDE
DETAILING & DESIGN
INFO FOR SOFFIT
PANELS & RAILS
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: CONFIRM
WOOD NAILERS
PER RFI-187
NBBJ: GC NOTE - MAINTAIN
ROOF MEMBRANE
CONTINUITY TO
INSULATED METAL PANEL
SYSTEM
NBBJ: ALTERNATE DETAIL
SUGGESTED, EXTENDING
INSULATED PANELS DOWN TO
WINDOW HEAD & ANCHORING
HSS TO "KARRIER" RAIL AS
SHOWN. PLEASE CONFIRM IF
VIABLE.
NBBJ: GC NOTE - MAINTAIN ROOF
MEMBRANE CONTINUITY TO
INSULATED METAL PANEL SYSTEM
NBBJ: CONFIRM
WOOD NAILERS
PER RFI-187
NBBJ: PROVIDE
DETAILING &
DESIGN INFO FOR
SOFFIT PANELS &
RAILS
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: CONFIRM
WOOD NAILERS
PER RFI-187
NBBJ: GC NOTE - MAINTAIN ROOF
MEMBRANE CONTINUITY TO
INSULATED METAL PANEL SYSTEM
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: SEAL BETWEEN
SILL PAN & TOP OF
PANEL TRIM (TYP)
NBBJ: EXTEND SILL PAN
TO ALLOW FOR INNER
SEAL CONTINUITY
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: SEAL BETWEEN
SILL PAN & TOP OF
PANEL TRIM (TYP)
NBBJ: EXTEND SILL PAN
TO ALLOW FOR INNER
SEAL CONTINUITY
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: WINDOW JAMB TO
ADJOIN ENTRY FRAME.
INSULATED PANEL WALL
SLIVER NOT REQUIRED.
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: SEAL BOTTOM
OF PANEL TRIM TO
FOUNDATION
INSULATION (TYP)
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: CORNER JOINT ALTERNATE 1:
KINGSPAN STANDARD MITERED
OUTSIDE CORNER DETAIL
KPH-OC-01-MTLV W/ BACKUP ANGLE &
MARRIAGE BEADS TO HORIZONTAL
SEALANT JOINTS (SEE MARKUPS ON
48/DET FOR ALTERNATE 2)
NBBJ: CORNER JOINT ALTERNATE 2:
PANELS OVERLAPPED AS SHOWN.
OVERLAPPING PANEL KERFED ON
BACKSIDE TO PROVIDE THERMAL
BREAK, PANEL HORIZONTAL SEALANT
BEADS CONTIGUOUS W/ VERTICAL
BEADS. (SEE MARKUPS ON 47/DET FOR
ALTERNATE 1)
KERF
HORIZONTAL
SEALANT BEADS
CONTIGUOUS W/
VERTICAL BEADS
(TYP)
NBBJ: ALTERNATE 1 OR 2
CORNER DETAIL PER MARKUPS
ON 47/DET OR 48/DET
NBBJ: SEAL BOTTOM
OF PANEL TRIM TO
FOUNDATION
INSULATION (TYP)
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: SEAL BOTTOM
OF PANEL TRIM TO
FOUNDATION
INSULATION (TYP)
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: NOTE - COORDINATE
DETAIL W/ CURRENT 7/A8.06
NBBJ: ALTERNATE 1 OR 2
CORNER DETAIL PER MARKUPS
ON 47/DET OR 48/DET
NBBJ: BACKUP TRIM & BUTYL MARRIAGE
BEAD TO HORIZONTAL PANEL SEAL PER
KINGSPAN STANDARD DETAIL TO MAINTAIN
AIR BARRIER CONTINUITY & COVER FOAM
PANEL END OPEN TO WALL CAVITY(TYP)
NBBJ: SEE MARKUPS ON S01-DET
NBBJ: GC NOTE -
PROVIDE FRAMING
BACKUP ADJACENT
CURTAINWALL JAMB
NBBJ: GC NOTE -
FLEX-FLASHING TO
CURTAINWALL JAMB INNER
SEAL AS NECESSARY TO
MAINTAIN AIR BARRIER
NBBJ: EXTEND
INSULATED PANEL TO
CURTAINWALL JAMB
R.O. PROFILE
NBBJ: TWO
PART FLASHING
NBBJ: CURTAINWALL PRIMARY
SEAL @ LEADING EDGE OF
JAMB - MAINTAIN AIR BARRIER
TO THAT POINT
NBBJ: METAL TRIM W/
"V" MOVEMENT BEND
SEALED TO PANELS
NBBJ: COMPRESSIBLE
FOAM FILL
NBBJ: CONFIRM
WOOD NAILERS
PER RFI-187
NBBJ: GC NOTE - MAINTAIN ROOF
MEMBRANE CONTINUITY TO
INSULATED METAL PANEL SYSTEM
NBBJ: CONFIRM
WOOD NAILERS
PER RFI-187
NBBJ: GC NOTE - MAINTAIN
ROOF MEMBRANE CONTINUITY
TO SKYLIGHT SYSTEM
NBBJ: SEE MARKUPS ON 74-DET
NBBJ: CONFIRM
WOOD NAILERS
PER RFI-187
NBBJ: SEE MARKUPS ON 74-DET
NBBJ: SEE MARKUPS ON 73-DET
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: CONFIRM
WOOD NAILERS
PER RFI-187
NBBJ: ALTERNATE 1 OR 2
CORNER DETAIL PER MARKUPS
ON 47/DET OR 48/DET
NBBJ: ALTERNATE 1 OR 2
CORNER DETAIL PER MARKUPS
ON 47/DET OR 48/DET
NBBJ: TRIM ENDS SO NO EXPOSED
FOAM TO WALL CAVITY (TYP)
NBBJ: TRIM ENDS SO NO
EXPOSED FOAM TO WALL
CAVITY (TYP)
NBBJ: INSULATED METAL PANEL -
MAINTAIN AIR BARRIER
CONTINUITY & SEAL TO SILL PAN
NBBJ: ALTERNATE 1 OR 2
CORNER DETAIL PER MARKUPS
ON 47/DET OR 48/DET
NBBJ: INSIDE CORNER
PER MARKUPS ON 65-DET
NBBJ: TWO PART
TRIM W/ THERMAL
BREAK
NBBJ: GC NOTE - PROVIDE
FLEXI-FLASH AS REQUIRED
TO MAINTAIN AIR BARRIER
CONTINUITY TO INNER SEAL
NBBJ: INSULATED
METAL PANEL
SYSTEM BACKUP
NBBJ: THERMALLY BROKEN
TRANSITION DETAIL W/ AIR
BARRIER CONTINUITY AS MARKED
UP ELSEWHERE IN THIS SUBMITTAL
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: SEAL BOTTOM
OF PANEL TRIM TO
FOUNDATION
INSULATION (TYP)
NBBJ: NO EXPOSED
FOAM TO CEILING OR
WALL CAVITIES (TYP)
NBBJ: THERMALLY BROKEN
& SEALED 2 PART ANGLE
FLASHING RECOMMENDED
IN LIEU OF CHANNEL (TYP)
NBBJ: SEAL BOTTOM
OF PANEL TRIM TO
FOUNDATION
INSULATION (TYP)
NBBJ: NOT REVIEWED
UNDER THIS SUBMITTAL
NBBJ: NOT REVIEWED
UNDER THIS SUBMITTAL
NBBJ: NOT REVIEWED
UNDER THIS SUBMITTAL
NBBJ: NOT REVIEWED
UNDER THIS SUBMITTAL
NBBJ: NOT REVIEWED
UNDER THIS SUBMITTAL
NBBJ: NOT REVIEWED
UNDER THIS SUBMITTAL
NBBJ: NOT REVIEWED
UNDER THIS SUBMITTAL
NBBJ: NOT REVIEWED
UNDER THIS SUBMITTAL
NBBJ: NOT REVIEWED
UNDER THIS SUBMITTAL
NBBJ: NOT REVIEWED
UNDER THIS SUBMITTAL
NBBJ: NOT REVIEWED
UNDER THIS SUBMITTAL
NBBJ: NOT REVIEWED
UNDER THIS SUBMITTAL
NBBJ: NOT REVIEWED
UNDER THIS SUBMITTAL
NBBJ: NOT REVIEWED
UNDER THIS SUBMITTAL
NBBJ: NOT REVIEWED
UNDER THIS SUBMITTAL