078446.001-0 Fire-Resistive_Joint_Systems_NBBJ-PAAN.pdf
Page 1of 1
CONTRACTOR SUBMITTAL ISSUE TO NBBJ
NBBJ Submittal Number
DATE ISSUEDDec 9, 2014
113-078446-0
COMPANYNBBJ
GC Submittal Number
113-078446001-0
223 Yale Avenue North
Seattle, WA 98109
SPEC. PARAGRAPH:
PHONE / FAX(206) 223-5555
Fire-Resistive Joint
SPEC. DESCRIPTION:
Systems
PROJECT NUMBER100822.06
Fire Resistive Joint
PROJECT NAMESMC Edmonds ACC
SPECIFIC ITEM:
Systems
ATTENTION:Barb Gipple
CONTRACTOR ISSUED ON:Dec 9, 2014
DATE REQUESTED BACK:Dec 23, 2014
DATE RECEIVED @ NBBJ:Dec 9, 2014
DATE DUE BACK TO
Dec 23, 2014
CONTRACTOR:
DATE RETURNED BY NBBJ:
12/18/14
COPIES
ITEMS TRANSMITTED
SENT VIA
REVIEW ACTIONPartially approved as noted
REVIEW NOTE
GC REMARKS
NBBJ COMPOSITE RESPONSE
Entered By:
Andris Lapins
Entered Date:
Thursday, December 18, 2014 2:33 PM
Partially approved as noted. Revise & resubmit Level One remodel area per ASI-07.
Partially approved as noted. Revise & resubmit Level One remodel area per ASI-07.
CONSULTANTS REPRESENTED
ISSUED BY Scott Solberg
PHONE / FAX:(206) 682-7770
NBBJAndris Lapins
NBBJRachel Jenner
EMAIL:scott.solberg@sellen.com
COPY TO:Dan Schnebele
Jenna Shope
Mark Bucek
ELECTRONIC ATTACHMENTS
0113-078446001-0_Fire-Resistive_Joint_Systems_NBBJ-PAAN.pdf
htts://secure1.nbb.com/CATools/Data/SubForm.asx?SubmittalID=127701218201
pjp9//4
1 | Page
SUBMITTAL FOR APPROVAL
Submittal #: 113 -078446.001
Rev#: 0
7039. - SWEDISH/EDMONDS-AMBULATORY CARE
Priority: Medium
CENTER
Date: 12/09/2014
To: RACHEL JENNER From: SCOTT SOLBERG
NBBJ SELLEN CONSTRUCTION CO., INC.
223 Yale Ave 227 WESTLAKE AVE N
Seattle, 98109 SEATTLE, WA 98109
Originator: EXPERT DRYWALL INC.
Description: Fire Resistive Joint Systems
We are transmitting the following Submittal Package item(s) for your review in accordance with the
contract specifications.
Please review and respond to: SCOTT SOLBERG, by: 12/23/2014.
Additional Notes:
Item Number Spec Section Description Details Notes
113-001.0 078446 Fire Resistive Joint Systems
cc:
December 04,
Swedish Edmonds Ambulatory Care Center SECTION 078446
NOTE: Partial Submittal
Construction Documents FIRE-RESISTIVE JOINT SYSTEMS
Expert Drywall is contracted to supply & install
10 June 2014
Joints at the perimeter of GWB assemblies only.
No other joints are part of our work.
SECTION 078446 - FIRE-RESISTIVE JOINT SYSTEMS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Fire-resistive joint systems in or between fire-resistance-rated
constructions including, but not limited to, the following:
1. Joints in or between fire-resistance-rated constructions.
2. Joints at exterior curtain-wall/floor intersections.
3. Joints in smoke barriers.
B. Related Sections:
1. 07 8413 - Penetration Firestopping: For systems installed in openings in walls
and floors with and without penetrating items.
1.2 SUBMITTALS
A. Product Data: For each type of product indicated.
See Part 2
B. Product Schedule: For each fire-resistive joint system. Include location and design
Pages 6-8
designation of qualified testing agency.
1. Where Project conditions require modification to a qualified testing agency's
illustration for a particular fire-resistive joint system condition, submit illustration,
with modifications marked, approved by fire-resistive joint system manufacturer's
fire-protection engineer as an engineering judgment or equivalent
fire-resistance-rated assembly.
Will be
C.Installer Certificates: From Installer indicating fire-resistive joint systems have been
submitted upon
installed in compliance with requirements and manufacturer's written
completion.
recommendations.
D.Product test reports.
Pages 27-47
1.3 QUALITY ASSURANCE
A. Installer Qualifications: A firm experienced in installing fire-resistive joint systems
similar in material, design, and extent to that indicated for this Project, whose work has
resulted in construction with a record of successful performance. Qualifications
include having the necessary experience, staff, and training to install manufacturer's
products per specified requirements. Manufacturer's willingness to sell its
fire-resistive joint system products to Contractor or to Installer engaged by Contractor
does not in itself confer qualification on buyer.
B. Fire-Test-Response Characteristics: Fire-resistive joint systems shall comply with the
following requirements:
1. Fire-resistive joint system tests are performed by a qualified testing agency
acceptable to authorities having jurisdiction.
Swedish Edmonds ACC
Expert Drywall, Inc.
NBBJ Project No. 100822.06 078446 - 1
078446 Submittal
Page 01
Swedish Edmonds Ambulatory Care Center SECTION 078446
Construction Documents FIRE-RESISTIVE JOINT SYSTEMS
10 June 2014
2. Fire-resistive joint systems are identical to those tested per testing standard
referenced in "Fire-Resistive Joint Systems" Article. Provide rated systems
complying with the following requirements:
a. Fire-resistive joint system products bear classification marking of qualified
testing agency.
b. Fire-resistive joint systems correspond to those indicated by reference to
designations listed by the following:
1) UL in its "Fire Resistance Directory."
2) Intertek ETL SEMKO in its "Directory of Listed Building Products."
1.4 COORDINATION
A. Coordinate construction of joints to ensure that fire-resistive joint systems are installed
according to specified requirements.
B. Coordinate sizing of joints to accommodate fire-resistive joint systems.
C.Notify Owner's testing agency at least seven days in advance of fire-resistive joint
system installations; confirm dates and times on day preceding each series of
installations.
PART 2 - PRODUCTS
2.1 FIRE-RESISTIVE JOINT SYSTEMS
A. Where required, provide fire-resistive joint systems that are produced and installed to
Acknowledged
resist spread of fire according to requirements indicated, resist passage of smoke and
other gases, and maintain original fire-resistance rating of assemblies in or between
which fire-resistive joint systems are installed. Fire-resistive joint systems shall
accommodate building movements without impairing their ability to resist the passage
of fire and hot gases.
B. Joints in or between Fire-Resistance-Rated Construction: Ratings determined per
Pages 11-20
ASTM E 1966 or UL 2079:
1. Fire-Resistance Rating: Equal to or exceeding the fire-resistance rating of
construction they will join.
2. Manufacturers: Subject to compliance with requirements, available
manufacturers offering products that may be incorporated into the Work include,
For head-of-wall joint,
but are not limited to, the following:
see substitution
a. A/D Fire Protection Systems Inc.
request on pages
b. CEMCO.
9-19.
c. Fire Trak Corp.
d. Grace Construction Products.
For end-of-wall and
bottom-of-wall, see
e. Hilti, Inc.
Hilti, Inc.
e.
page 20.
f. Johns Manville.
g. Nelson Firestop Products.
h. NUCO Inc.
i. Passive Fire Protection Partners.
Swedish Edmonds ACC
Expert Drywall, Inc.
NBBJ Project No. 100822.06 078446 - 2
078446 Submittal
Page 02
Swedish Edmonds Ambulatory Care Center SECTION 078446
Construction Documents FIRE-RESISTIVE JOINT SYSTEMS
10 June 2014
j. RectorSeal Corporation.
k. Specified Technologies Inc.
l. 3M Fire Protection Products.
m. Tremco, Inc.; Tremco Fire Protection Systems Group.
n. USG Corporation.
C.Joints at Exterior Curtain-Wall/Floor Intersections: Provide fire-resistive joint systems
N/A
consisting of mineral fiber safing and smoke seal compound with rating determined by
ASTM E 119 based on testing at a positive pressure differential of 0.01-inch wg (2.49
Pa) or ASTM E 2307.
1. Fire-Resistance Rating: Equal to or exceeding the fire-resistance rating of the
floor assembly.
2. Manufacturers: Subject to compliance with requirements, available
manufacturers offering products that may be incorporated into the Work include,
but are not limited to, the following:
a. A/D Fire Protection Systems Inc.
b. Grace Construction Products.
c. Hilti, Inc.
d. Johns Manville.
e. Nelson Firestop Products.
f. NUCO Inc.
g. Passive Fire Protection Partners.
h. RectorSeal Corporation.
i. Specified Technologies Inc.
j. 3M Fire Protection Products.
k. Thermafiber, Inc.
l. Tremco, Inc.; Tremco Fire Protection Systems Group.
m. USG Corporation.
D.Joints in Smoke Barriers: Ratings determined per UL 2079.
Pages 21-24
1. L-Rating: Not exceeding 5.0 cfm/ft (0.00775 cu. m/s x m) of joint at 0.30 inch wg
(74.7 Pa) at both ambient and elevated temperatures.
2. Manufacturers: Subject to compliance with requirements, available
manufacturers offering products that may be incorporated into the Work include,
but are not limited to, the following:
a. A/D Fire Protection Systems Inc.
b. Grace Construction Products.
See note
c. Hilti, Inc.
Hilti 506 gun-grade will be used at the base/ends of walls
Hilti, Inc.Hilti, Inc.Hilti, Inc.
c.
at right
where there is a small and uniform joint.
d. Johns Manville.
Hilti 572 spray grade will be used with mineral wool backer
e. Nelson Firestop Products.
at the top of wall and other large/irregular voids
f. NUCO Inc.
g. Passive Fire Protection Partners.
h. RectorSeal Corporation.
i. Specified Technologies Inc.
j. 3M Fire Protection Products.
k. Tremco, Inc.; Tremco Fire Protection Systems Group.
l. USG Corporation.
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
NBBJ Project No. 100822.06 078446 - 3
Page 03
Swedish Edmonds Ambulatory Care Center SECTION 078446
Construction Documents FIRE-RESISTIVE JOINT SYSTEMS
10 June 2014
Pages 12&20
E. Exposed Fire-Resistive Joint Systems: Provide products with flame-spread and
smoke-developed indexes of less than 25 and 450, respectively, as determined per
ASTM E 84.
Pages 25&26
F. Accessories: Provide components of fire-resistive joint systems, including primers
and forming materials, that are needed to install fill materials and to maintain ratings
required. Use only components specified by fire-resistive joint system manufacturer
and approved by the qualified testing agency for systems indicated.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Examine substrates and conditions, with Installer present, for compliance with
Acknowledged
requirements for joint configurations, substrates, and other conditions affecting
performance of the Work.
B. Install fire-resistive joint systems to comply with manufacturer's written installation
Acknowledged
instructions and published drawings for products and applications indicated.
C.Install forming materials and other accessories of types required to support fill
Acknowledged
materials during their application and in position needed to produce cross-sectional
shapes and depths required to achieve fire ratings indicated.
1. After installing fill materials and allowing them to fully cure, remove combustible
forming materials and other accessories not indicated as permanent components
of fire-resistive joint system.
D.Install fill materials for fire-resistive joint systems by proven techniques to produce the
Acknowledged
following results:
1. Fill voids and cavities formed by joints and forming materials as required to
achieve fire-resistance ratings indicated.
2. Apply fill materials so they contact and adhere to substrates formed by joints.
3. For fill materials that will remain exposed after completing the Work, finish to
produce smooth, uniform surfaces that are flush with adjoining finishes.
We believe that the identification provided by specification section 070553 fulfills
3.2 IDENTIFICATION
this requirement. If the intent of this specification is to provide signage in addition
to 070553, please advise regarding the location and spacing of these signs.
See note
A. Identify fire-resistive joint systems with preprinted metal or plastic labels. Attach
at right
labels permanently to surfaces adjacent to and within 6 inches (150 mm) of joint edge
so labels will be visible to anyone seeking to remove or penetrate joint system. Use
mechanical fasteners or self-adhering-type labels with adhesives capable of
permanently bonding labels to surfaces on which labels are placed. Include the
following information on labels:
1. The words "Warning - Fire-Resistive Joint System - Do Not Disturb. Notify
Building Management of Any Damage."
NBBJ: 070553 LABELING IS FOR RATED
2. Contractor's name, address, and phone number.
PARTITIONS SATSIFYING IBC 703.7. LABELING
3. Designation of applicable testing agency.
PER 078446, 3.2 IS INTENDED TO IDENTIFY
4. Date of installation.
SPECIFIC FIRE-RESISTIVE JOINT SYSTEMS
Swedish Edmonds ACC
USED AT ANY SPECIFIC LOCATION.
Expert Drywall, Inc.
REQUIREMENT STANDS. NOT NECESSARY
078446 Submittal
NBBJ Project No. 100822.06 078446 - 4
HOWEVER, AT BASE OF WALL CONDITIONS IN
Page 04
FINISHED SPACES. MAXIMUM SPACING 30'
AND WITHIN 15' OF CORNERS.
Swedish Edmonds Ambulatory Care Center SECTION 078446
Construction Documents FIRE-RESISTIVE JOINT SYSTEMS
10 June 2014
5. Manufacturer's name.
6. Installer's name.
3.3 FIELD QUALITY CONTROL
Acknowledged
A. Inspecting Agency: Owner will engage a qualified testing agency to perform tests and
inspections.
Acknowledged B. Where deficiencies are found or fire-resistive joint systems are damaged or removed
due to testing, repair or replace fire-resistive joint systems so they comply with
requirements.
C.Proceed with enclosing fire-resistive joint systems with other construction only after
Acknowledged
inspection reports are issued and installations comply with requirements.
END OF SECTION
Swedish Edmonds ACC
Expert Drywall, Inc.
NBBJ Project No. 100822.06 078446 - 5
078446 Submittal
Page 05
Expert Drywall, Inc.
December 04, 2014
F & S RATINGS
UP
URGENT CARE SUITE
1P119' - 0"UP
OCC. LOAD - 54
5377 SF
ASSEMBLY CEILING
1hr Shaftwall
NBBJ: SMOKE
FEC
Ceiling
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
FEC
Page 06
2hr Shaftwall
Ceiling
ED SUITE - EAST
OCC. LOAD - 99
9884 SF
FEC
FEC
1hr Shaftwall
FEC
FEC
COMPARTMENT 1C
Ceiling
ED SUITE - WEST
LOBBY SMOKE
OCC. LOAD - 150
OCC. LOAD - 96
14984 SF
9593 SF
UP
FEC
UP
FEC
ASSEMBLY CEILING
NBBJ: SMOKE
FEC
IMAGING SUITE
OCC. LOAD - 57
FEC
RESUBMIT REMODEL
AREA PER ASI-07.
FEC
5703 SF
NBBJ: REVISE &
Hilti 572 spray grade will be used with mineral wool backer at the Head-of-Wall per Team Design dated October 23, 2014 (page 48)
Dashed line indicates wall terminates at rated ceiling - no
Hilti 506 gun-grade will be used at the base/ends of walls where
FEC
G
FEC
Special 2 HR Fire-Resistive Assembly for Gypsum Shaftwall
G
1 or 2 HR Fire-Resistive Assembly for Gypsum Wallboard
F
2 HR Fire-Resistive Assembly for Gypsum Shaftwall
F
F
E
head-of-wall design is needed for this area.
top of wall and other large/irregular voids
FEC
UL Design HW-D-499, 500 or 513 Bottom-of-Wall UL Design BW-S-002
E
Bottom-of-Wall UL Design BW-S-023 Bottom-of-Wall UL Design BW-S-023
there is a small and uniform joint.
Head-of-Wall UL Design HW-D-504
D
FEC
C
O
R
RI
D
OR
FEC
D
A
U
TO
EM
QUA
ITE
P.D
R
O
SO
TM
AI
R
C
OBSERVATION
OCC. LOAD - 58
(REMODEL)
5744 SF
C
O
RR
ID
O
R
Smoke Assembly
C
O
R
R
ID
O
R
C
VE
S
TI
B
UL
E
B
V
E
S
JATIB
NU
ITL
OE
R
W
OM
E
N
TOS
IL'
E
T
D
MN
E
N
S'
TO
IL
E
T
'
A
DC
AON
RKT
RRO
OAL
OR
MEA
X-
R
A
RY
O
O
M
FEC
X
-
R
A
RY
O
O
M
A
B
TO
IL
E
T
A
LC
O
V FEC
E
D
RE
S
S
.
G
O
W
N
H &
AM
P
E
R
D
RE
S
3 S
.T
AO
LCIL
OET
V
E
2
.
2 D
RE
S
S
.
2
T
O
ILE
T
1
Head-of-Wall per Team Design dated October 23, 2014 (page 48)
Dashed line indicates wall terminates at rated ceiling - no
Hilti 506 gun-grade will be used at the base/ends of walls where
D
N
D
N
ISSUE MARKDATEDESCRIPTION
Expert Drywall, Inc.
December 04, 2014
F & S RATINGS
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
UP
Page 07
FEC
OCC. LOAD - 211 (FUTURE)
COMPARTMENT 2A
21057 SF
SMOKE
FEC
FEC
Hilti 572 spray grade will be used with mineral wool backer at the
Hilti 506 gun-grade will be used at the base/ends of walls where
1 or 2 HR Fire-Resistive Assembly for Gypsum Wallboard
2 HR Fire-Resistive Assembly for Gypsum Shaftwall
top of wall and other large/irregular voids
UL Design HW-D-499, 500 or 513 Bottom-of-Wall UL Design BW-S-002
Bottom-of-Wall UL Design BW-S-023
there is a small and uniform joint.
Head-of-Wall UL Design HW-D-504
FEC
Smoke Assembly
Head-of-Wall UL Design HW-D-504
Hilti 506 gun-grade will be used at the base/ends of walls where
Expert Drywall, Inc.
December 04, 2014
F & S RATINGS
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 08
Hilti 572 spray grade will be used with mineral wool backer at the
Hilti 506 gun-grade will be used at the base/ends of walls where
1 or 2 HR Fire-Resistive Assembly for Gypsum Wallboard
2 HR Fire-Resistive Assembly for Gypsum Shaftwall
top of wall and other large/irregular voids
UL Design HW-D-499, 500 or 513 Bottom-of-Wall UL Design BW-S-002
Bottom-of-Wall UL Design BW-S-023
there is a small and uniform joint.
Head-of-Wall UL Design HW-D-504
Smoke Assembly
2 HR Fire-Resistive Assembly for Gypsum Shaftwall
Smoke Assembly
1 or 2 HR Fire-Resistive Assembly for Gypsum Wallboard
SUBSTITUTION FOR CONVENIENCE: Requested substitution offers the following
SECTION 01 2501
Swedish Edmonds Ambulatory Care Center
Construction Documents SUBSTITUTION REQUEST FORM
10 June 2014
Substitution Request Number:
TO: NBBJ, 223 Yale Avenue North, Seattle WA 98109.
Attn:
FROM:
Expert Drywall, Inc.
Specification Section: 078446 Fire-Resistive Joint Systems
Article and Paragraph(s): 2.6.B. Joints in or between Fire-Resistance-Rated Construction
Fire-resistive joint treatment - 14 manufacturers listed
Specified Item:
Proposed Substitution: Fire-resistive joint treatment - manufactured by BlazeFrame, which was
not one of the specified manufacturers, but is similar to CEMCO's product.
SUBSTITUTION FOR CAUSE: Required due to change in project conditions as follows:
Unavailability of Product:
Unsuitability:
Regulatory Change:
Unavailability of Required Warranty:
SUBSTITUTION FOR CONVENIENCE: Requested substitution offers the following
SUBSTITUTION FOR CONVENIENCE: Requested substitution offers the following
substantial advantage(s) to Owner:
Cost (Dollar Amount):
None.
Time (Days):
Expert's scope will install faster and is not affected by weather
Energy Conservation (Dollar Amount):
None.
Other (Explain):
None.
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
NBBJ Project No. 100822.06 01 2501 - 1
Page 09
SECTION 01 2501
Swedish Edmonds Ambulatory Care Center
Construction Documents SUBSTITUTION REQUEST FORM
10 June 2014
The Undersigned certifies that:
Proposed substitution meets requirements stipulated in Section 01 2500 - Substitution
Procedures.
Required documentation for proposed substitution is provided in accordance with Sec-
Required documentation for proposed substitution is provided in accordance with Sec-
tion 01 2500 - Substitution Procedures.
tion 01 2500 - Substitution Procedures.
Proposed substitution has been fully investigated and determined to be equal or superior
to specified item.
Same warranty will be furnished for proposed substitution as for specified item.
Proposed substitution will have no adverse effect on other Work and will not affect or de-
lay progress schedule.
Cost data stated is complete. Claims for additional costs related to accepted substitution
which may subsequently become apparent are waived.
Proposed substitution does not affect dimensions and functional clearances.
CERTIFICATION OF EQUAL PERFORMANCE AND ASSUMPTION OF LIABILITY FOR
EQUAL PERFORMANCE
Submitted By (Contractor):_______________________________________________________
Expert Drywall, Inc.
Signature __________________________________________________ Date _____________ Nov 24, 2014
Printed Name and Title _________________________________________________________
Mark Leavitt, Project Manager
Signature must be by person having authority to legally bind his firm to the above terms.
Failure to provide legally binding signature will result in retraction of approval
ARCHITECT'S REVIEW AND ACTION
X
____Substitution Approved
____Substitution Approved as Noted
____Substitution Rejected
Andris Lapins
12/18/14
Signature: ____________________________________________________ Date ___________
Andris Lapins, Senior Associate, NBBJ
Printed Name and Title __________________________________________________________
Additional Comments:
_____________________________________________________________________________
_____________________________________________________________________________
_____________________________________________________________________________
END OF SECTION
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
NBBJ Project No. 100822.06 01 2501 - 2
Page 10
Swedish Edmonds ACC
BlazeFrame Ind.
Expert Drywall, Inc.
8805 NE 148Ave NE
th
078446 Submittal
Redmond, WA
Page 11
425-869-2811
www.blazeframe.com
Project Submittal – Basic Coated Metal Deck
1. Product Description
3. Testing Data
A strip of highly intumescent
It has been tested as a dynamic and static
fire stop material affixed to metal profiles
joint protection fire stop sealant to ASTM E-
When exposed to heat, this product
814, UL 1479, and UL 2079. Complies to
expands and forms a hard char to seal
Required Environmental Exposure Testing
off joint (gap) preventing passage of flames,
of Accelerated Aging and High Humidity as
temperature pass through, and hot gases.
per UL 1479 Fire Test of Through-
Penetration Firestops.
2. Material Properties
Degree of intumescence per DIN standard
Asbestos Fillers: None
18x with weight imposed
Solvents: None
37x free intumescing
Hazardous Ingredients: None
Thickness: 2 mm
ASTM E 84, UL 723 Tunnel Test
ASTM E 84, UL 723 Tunnel Test
Width: Per BlazeFrame Profile
Flame Spread 5
Flame Spread 5
Activation of Intumescence:
Smoke Index 5
Smoke Index 5Smoke Index 5
2.1.E
Expansion Begins 375 F (190C)
Expansion Greatest 575 (302 C)
to 1100 F (593 C)
Color: Black
Exposed Surface: Poly Coating
Freeze-Thaw: Excellent
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 12
12
www.blazeframe.com
0±®£´¢³ 0±®¥¨«¤ $¨¬¤²¨®²
PS5 - -
Composite Fire Stop/Framing for use in up to 3 hr rated wall assemblies,
movement with level III (seismic) certification. Minimum G40 (20ga) and G60 (18ga and
hstuds per listed
assemblies
spray fire proofing.
(G)
(I)
(L1)
(S)
Patented
1.00"
.25"
Fastener mid-height
of exposed slot
Part Identification
Widths (W) Mil (Ga)
250 (2 1/2").030 (20)
362SLCD2 - 30
Example:
362 (3 5/8")
.033 (20)
-
362SLCD230
400 (4")
.043 (18)
600 (6").054 (16)
800 (8").068 (14)Series
Track Width
Gauge
Profile
1 - Series (Fire Stop One Side)2 - Series (Fire Stop Both Sides)
(W)(W)
(G)
(G)
(L2)(L2)
(L1)
(L1)
GapSlotted Leg LengthSolid Leg Length
Profile Joint
Strip WidthSlot Height
(G)Protection
(L1)(L2)
(I)(S)
SLCD.50"
1.00"
3.00"2.00"1.50"
.75"
.50"
SLWCD3.25"2.00"1.50"
1.00"
1.25"
SLXCD
.50"4.25"2.50"2.00"
1.50"
1.75"
UL, ASTM & Code StandardsLeed Points
UL2079, E814, E1966, ULC S115-M95 MR 2.1 & 2.2 - Construction Waste: up to 2pts
UL207
9, E814, E1966, ULC S115
ASTM E814, E1966 MR 4.1 & 4.2 - Recycled Content: up to 2 pts
A1003, A653, A924, C645, C754, C955 MR 5.1 & 5.2 - Regional Proximity
AISI 2004 NAS EQ 4.1 - Low Emitting Materials
2009 IBC & 2013 CBC EQ 9 - Enhanced Acoustical
Swedish Edmonds ACC
Expert Drywall, Inc.
¶¶¶ȁ¡« ¹¤¥± ¬¤ȁ¢®¬
2.1.B
078446 Submittal
0§®¤Ȁ ȨΓΑΔȩ ΗΕΘȃΑΗΐΐ & ·Ȁ ȨΓΑΔȩ ΗΕΘȃΑΒΏΏ
Page 13
0±®£´¢³ 0±®¥¨«¤ $¨¬¤²¨®²
PS49 - Slotted J-Runner Profiles one slotted and one solid leg
Composite Fire Stop/Framing for use in up to 2 hr rated
movement with level III (seismic) certification. Minimum G40 (20ga) and G60 (18ga and
heavier) coating having studs per
.
listed assemblies in UL Fire Resistance Directory
(I)
(L1)
(S)
Patented
.25"
1.00"
Fastener mid-height
of exposed slot
Mil (Ga)
Widths (W) Part Identification
250 (2 1/2").030 (20)
Example:
400JRS-30
400 (4")
.033 (20)
-
30
400JRS
.043 (18)
600 (6")
.054 (16)
Track Width
Gauge
Profile
(W)
(L2)
(L1)
ProfileSlotted Leg LengthSolid Leg LengthStrip WidthJoint
Slot Height
(L1)(L2)Protection
(I)(S)
2.50"1.00"
JRSE3.00".75".50"
1.00"
.75"
JRS3.00"3.00"1.50"
1.00"
3.00"
JRSW3.00"1.25"1.50"
4.00"
JRSX2.00"1.50"
3.00"1.75"
UL, ASTM & Code StandardsLeed Points
UL2079, E814, E1966, ULC S115-M95 MR 2.1 & 2.2 - Construction Waste: up to 2pts
UL2079, E814, E1966, ULC S115
A1003, A653, A924, C645, C754, C955 MR 4.1 & 4.2 - Recycled Content: up to 2 pts
AISI 2004 NAS MR 5.1 & 5.2 - Regional Proximity
2006 & 2009 IBC EQ 4.1 - Low Emitting Materials
2013 CBC EQ 9 - Enhanced Acoustical
Swedish Edmonds ACC
¶¶¶ȁ¡« ¹¤¥± ¬¤ȁ¢®¬
Expert Drywall, Inc.
2.1.B
0§®¤Ȁ ȨΓΑΔȩ ΗΕΘȃΑΗΐΐ & ·Ȁ ȨΓΑΔȩ ΗΕΘȃΑΒΏΏ
078446 Submittal
Page 14
DžɝɚɕɐɎɟ LjɠɍɘɔɟɟɌɗ ƸɚɌɟɐɏ ƹɐɎɖ Ɍəɏ ƸɚɌɟɐɏ ƷɐɌɘɞ
Fastener Attachment 24" O/C max.
Fastener Attachment 24" O/C max.
Fire Proofing or
Mineral Wool
Installed Gap
BlazeFrame Composite
(See Notes)
Installed Gap
Track/Fire Stop
(See Notes)
BlazeFrame Composite
1" to 4"Composite Track/Fire Stop
(See Notes)"CD" Profile
1" to 4"
(See Notes)
4 pcf Mineral Wool
compressed 33%
Steel Stud
Max 24" O/C
3 Layers for1" Shaft
Fastener below
Liner Board
3 Hour Rating
Obstruction
(when exists)
CH, CT, or I stud
Max 24" O/C
5/8" Type X
5/8 Type X
Gypsum Wallboard
Gypsum Wallboard
Perpendicular Flute & Parallel Beam Shaft Wall Perpendicular & Parallel Beam
1
2
BlazeFrame Det. PD1 BlazeFrame Det. PD6
UL Ref. HW-D-0512 UL Ref. HW-D-0504 & 0512
Fastener Attachment 24" O/C max.Fire Proofing
Fastener Attachment 16" O/C max.Fastener Attachment 24" O/C max.
Fire Proofing
Installed Gap Installed Gap
(Thickness by Others)
(See Notes)
(See Notes)
BlazeFrame Composite
BlazeFrame (FC)
Track/Fire Stop
Flute Cover
1" to 4"
1" to 4"
("CD" Profile)
(See Notes)
(See Notes)
BlazeFrame Composite
Track/Fire Stop
"CD" Profile
Steel Stud
Steel Stud 5/8" Type X
Max 24" O/C
Max 24" O/C
5/8" Type X
Gypsum Wallboard
Gypsum Wallboard
Centered Under Flute - Flute Cover
Centered Under Valley
3
4
BlazeFrame Det. PD3
BlazeFrame Det. PD5
UL Ref. HW-D-0512 & 0544
UL Ref. HW-D-0499 & 0512
Metal Pan Deck
Fireproofing
Metal Pan Deck
Structural Steel Support
Angle or Z-clip
Fire Proofing
centered track frame
and attached to beam
or Steel Track Frame
BlazeFrame Composite
Track/Fire Stop
BlazeFrame Composite
Fire Proofing or
Installed Gap per
Track/Sealant
Mineral Wool only
Deflection Requirements
encompass angle or z-clip"OL" - Series
Steel Stud
width of wall framing
Max 24" O/C
5/8 Type X
Gypsum Wallboard
Partition per
Schedule
Swedish Edmonds ACC
Under Beam - Offset Leg
Beam Penetration
5
6
Expert Drywall, Inc.
BlazeFrame Det. SS2
BlazeFrame Det. PD13
078446 Submittal
UL Ref. HW-D-0502
UL Ref. HW-D-0495 & 0512
Page 15
͎
ɢɢɢ̔ɍɗɌɥɐɑɝɌɘɐ̔Ɏɚɘ
DžɝɚɕɐɎɟ LjɠɍɘɔɟɟɌɗ ƸɚɌɟɐɏ ƹɐɎɖ Ɍəɏ ƸɚɌɟɐɏ ƷɐɌɘɞ
Metal Pan Deck
Min. 14ga strap/angle
Metal Pan Deck
Fastener Attachment
Structural Steel Support
Structural Steel
24" O/C max.
Support
Fire Proofing
Fire Proofing
Installed Gap per
BlazeFrame Composite
BlazeFrame Composite
Deflection Requirements
Track/Sealant
Track/Sealant
"OL" - Series
"OL" - Series
Installed Gap per
Deflection Requirements
Partition per
Schedule
Partition per
Schedule
Shaft Wall Under Beam - Offset Leg
Cantilevered Under Beam - Offset Leg
8
7
BlazeFrame Det. SS4
BlazeFrame Det. SS28
UL Ref. HW-D-0631
UL Ref. HW-D-0502
Metal Pan Deck
Structural Steel Support
Metal Pan Deck
Structural Steel Support
Fire Proofing
Z-Clip Attachment Clips
Z-Clip Attachment Clips
Fire Proofing
Installed Gap per
Installed Gap per
4 pcf Mineral Wool
Deflection Requirements
BlazeFrame Composite
compressed 33%
Deflection Requirements
Track/Sealant
BlazeFrame Composite
Track/Sealant
Partition per
Partition per
Schedule
Schedule
Shaft Wall Under Beam - Z-Clips
Under Beam - Z-Clips
10
9
BlazeFrame Det. SS20
BlazeFrame Det. SS16
UL Ref. HW-D-0631
UL Ref. HW-D-0502
Mineral Wool
Compressed 33%
Fastener Attachment intoFastener Attachment into
Mineral Wool
Z-Clip Outrigger 16" O/CZ-Clip Outrigger 16" O/C
Compressed 33%
Z-Clip OutriggerZ-Clip Outrigger
BlazeFrameBlazeFrame
"ISA" Profile
"ISA" Profile
Installed Gap per
Installed Gap per
Deflection Requirements
Deflection Requirements
BlazeFrame Composite
BlazeFrame Composite
Track/Sealant
Track/SealantPartition per
Partition per
Schedule
Schedule
Swedish Edmonds ACC
Parallel Beam >24" - Z-Clips/Drywall Rips Parallel Beam >24" - Z-Clips/Drywall Rips
12
11
Expert Drywall, Inc.
BlazeFrame Det. SS23 BlazeFrame Det. UD26
078446 Submittal
UL Ref. HW-D-0597 UL Ref. HW-D-0597/0504
Page 16
͏
ɢɢɢ̔ɍɗɌɥɐɑɝɌɘɐ̔Ɏɚɘ
DžɝɚɕɐɎɟ LjɠɍɘɔɟɟɌɗ ƸɚɌɟɐɏ ƹɐɎɖ Ɍəɏ ƸɚɌɟɐɏ ƷɐɌɘɞ
Fastener Attachment 24" O/C max.
Fire Proofing
Mineral Wool
Installed Gap per
Compressed 33%
Installed Gap
Deflection Requirements
(See Notes)
BlazeFrame
Composite
Track/Firestop
BlazeFrame Composite
"CD" Profile
1" to 4"
(See Notes)
Track/Sealant
Gusset Plate
Brace Studs
5/8" Type X
Partition per
Diagonal Bracing
Gypsum Wallboard
Steel Stud
Schedule
Structural Steel
Max 24" O/C
Chase Wall - Diagonal Bracing
Chase Wall - Perpendicular
14
13
BlazeFrame Det. PD2 BlazeFrame Det. SS33
UL Ref. HW-D-0506
UL Ref. HW-D-0506 & 0512
Fire Proofing
Fastener Attachment 24" O/C max.
25ga Hat Channel
16" O.C. to Support
Drywall Spans Over 16"
Drywall Control
Joint (Optional)
Installed Gap
(See Notes)
1" to 4"
BlazeFrame Composite
(See Notes)
Installed Gap per
Control Joint
Track/Fire Stop
(Optional)
Deflection Requirements
"CD" Series
Steel Stud
BlazeFrame Composite
Max 24" O/C
Track/Sealant
Fastener at Bottom Partition per
of Obstruction
Schedule
5/8" Type X
(when exists)
Gypsum Wallboard
Stair Shaft Beam - Control Joint
Stair Shaft - Control Joint
16
15
BlazeFrame Det. SS5
BlazeFrame Det. PD7
UL Ref. HW-D-0502/0543
UL Ref. HW-D-0512 & 0543
Fire Proofing Fastener Attachment 24" O/C max.
Fire Proofing
25ga Hat Channel
16" O.C. to Support
Drywall Spans Over 16"
Installed Gap
Z-Clip Attachment Clip
(See Notes)
(16" O/C)Control Joint
BlazeFrame Composite
(Optional)
Composite Track/Fire Stop
1" to 4"
"CD" Profile
(See Notes)
Installed Gap per
Deflection Requirements
BlazeFrame Composite
Track/Sealant
Partition per
5/8" Type X
Steel Stud
ScheduleGypsum Wallboard
Max 24" O/C
Swedish Edmonds ACC
Stair Shaft Beam Z-Clips - Control Joint
Offset Under Valley - Mineral Wool
18
17
Expert Drywall, Inc.
BlazeFrame Det. SS18
BlazeFrame Det. PD4
078446 Submittal
UL Ref. HW-D-0502/0543
UL Ref. HW-D-0499 & 0512
Page 17
͐
ɢɢɢ̔ɍɗɌɥɐɑɝɌɘɐ̔Ɏɚɘ
DžɝɚɕɐɎɟ LjɠɍɘɔɟɟɌɗ ƸɚɌɟɐɏ ƹɐɎɖ Ɍəɏ ƸɚɌɟɐɏ ƷɐɌɘɞ
Concrete Column/Wall
Fastener Attachment
24" O/C Max.
5/8" Type X
Gypsum Wallboard
Installed Gap per
Deflection Requirements
BlazeFrame Composite
Track/Sealant
"RCS" Profile
Steel Stud 3" from
Resilient Channel
BlazeFrame Profile
1/2" distance from
stud to drywall
Partition per
BlazeFrame "VT" Profile
Schedule
Installed Gap
(see notes)
Sound Wall - Resilient Channel Vertical Joint - Concrete
20
19
BlazeFrame Det. VM11
BlazeFrame Det. VM1
UL Ref. HW-D-0498 UL Ref. WW-S-0055
Fire Proof Coating
BlazeFrame Composite
Track/Sealant
Structural Steel Column
Steel Stud 3" from
BlazeFrame Profile
Partition per
Installed Gap
Schedule
max. 3/4" distance
Vertical Joint - I-Beam
21
BlazeFrame Det. VM3
UL Ref. WW-S-0055/HW-D-0558
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 18
͑
ɢɢɢ̔ɍɗɌɥɐɑɝɌɘɐ̔Ɏɚɘ
DžɝɚɕɐɎɟ LjɠɍɘɔɟɟɌɗ ƸɚɌɟɐɏ ƹɐɎɖ Ɍəɏ ƸɚɌɟɐɏ ƷɐɌɘɞ
BlazeFrame Benefits BlazeFrame Tested Wall Assemblies
Intumescent "gasket" Joint Protection 1/2" to 3/4" Exposed Deflection Gaps
Direct Attachment - No Caulk at Substrate 5/8" Type X Gypsum Sheathing
Reduced Sound Transfer - No Exposed Steel 3 1/2" Fiberglass Insulation Cavity Fill
Exposed Head of Wall and Deflection Gaps
Level III Dynamic Cycle (seismic) Rated
No Joint Fatigue - Lifetime Indefinite
Protection
NVLAP accredited -ASTM E90-04
Western Electro- Acoustic Laboratory
Reports Available Upon Request
STC - 52
STC - 56
Unbalanced - (Report # TL 13-223)
Balanced - (Report #TL 13-229)
STC - 67
STC - 66
Balanced - (Report #TL 13-230)
Unbalanced - (Report #TL 13-229)
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 19
͕
ɢɢɢ̔ɍɗɌɥɐɑɝɌɘɐ̔Ɏɚɘ
Product Information
2.1.B.2.e
Flexible Firestop Sealant
(CP 606)
Introduction
Product description
Product features
Paintable
Applications and Products
Technical Data* CP 606
Chemical basis
Color
Application temperature
and Coatings
Skin-forming time
Areas of application
Curing time
Average volume shrinkage
(ASTM C1241)
Movement capability
Selector Guide
Temperature resistance
Cable bundles
2.1.E
Surface burning characteristics
(ASTM E 84-96)
For use with
(ASTM E 90-99)
Tested in accordance with
Examples
Through-Penetration
Installation instructions for CP 606
Notice Storage
Not for use
JOINT
Joint
Opening
Application of firestop
DUCT
Reference Data
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Hilti. Outperform. Outlast.
Page 20
www.us.hilti.com
Product Information
CP 506
CP 506
CP 506
Smoke and Acoustic Sealant
Smoke and Acoustic Sealant
Applications
Advantages
Tested in accordance with:
ASTM E 90
Technical DataCP 506
Color
Chemical basis
Storage and transport temperature
range
Curing time
(73°F / 50% relative humidity)
Skin-forming time
(73°F / 50% relative humidity)
Application temperature range
ASTM E 90.
Shelf life
Volume shrinkage
(ASTM E90)
ASTM C 834
Movement capability (ISO 11600)
Mold and mildew (ASTM G21)
Surface burning characteristics
2.1.D.1
(ASTM E84)
Air leakage
Air leakage
DescriptionPackage ContentsItem No.
CP 506 smoke and acoustic sealant
(580 ml foil pack)
CP 506 smoke and acoustic sealant
(5 gallon pail)
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Hilti. Outperform. Outlast.
Page 21
Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.comwww.hilti.ca
11/2009
Product Information
General guidelines for Through-Penetration
common acoustic / smoke seal
applications
Note
Top of Wall
System STC = 63
Bottom of Wall
System STC = 63
System STC = 63
Installation instructions for CP 506
Notice Application of sealantNot for use
Storage
Opening
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Hilti. Outperform. Outlast.
Page 22
Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.comwww.hilti.ca
11/2009
Product Information
CP 572
CP 572
CP 572
Smoke and Acoustic Spray
Smoke and Acoustic Spray
Applications
Advantages
Technical DataCP 572
Color
Chemical basis
Storage and transport temperature
ASTM E 90.
range
Curing time approx.
(73°F / 50% relative humidity)
Skin-forming time
(73°F / 50% relative humidity)
Application temperature range
Shelf life
(ASTM E90-99)
Surface burning characteristics
(ASTM E84)
Movement capability
Mold and mildew (ASTM G21)
DescriptionPackage ContentsItem No.
CP 572 smoke and acoustic spray (5 gallon pail)
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Hilti. Outperform. Outlast.
Page 23
Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.comwww.hilti.ca
11/2009
Product Information
General guidelines for
common acoustic / smoke seal
applications
Top of Wall
Note
System STC = 54
Installation instructions for CP 572
Notice Application of sprayNot for use
Storage
Opening
Swedish Edmonds ACC
Expert Drywall, Inc.
Hilti. Outperform. Outlast.
078446 Submittal
Page 24
Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.comwww.hilti.ca
11/2009
2.1.F
TechnicalProductInformation
INSULATION 07840*
FIBROUS FIRE SAFING 07 84 56.13**
CURTAIN WALL & GLAZED
ASSEMBLIES 08 44 00**
GeneralProductInformation:Description&CommonApplications:
ROXUL® products are mineral wool fibre insulations made ROXULSafe®productisanon-combustible,lightweightand
from basalt rock and slag. This combination results in a non-waterrepellentsemi-rigidinsulationbatt thatprovidesfire
combustible product with a melting point of approximately stoppingandacousticalinsulationproperties. Specifically
2150°F (1177°C), which gives it excellent fire resistance engineered and produced as a fire stopping material for
properties.ROXULmineralwoolisawaterrepellentyet commercial, industrial and residential buildings, Roxul Safe
vapourpermeablematerial.canbe used for the following applications:
- perimeter gaps between concrete floor slabs and exterior
wall systems,
- around conduit pipe and duct openings through walls and
floor slabs,
- between fire walls and ceiling slabs.
This product has excellent fire performance properties, such
ashigh melt temperature and low thermal conductivity which
means the insulation acts as a shield against fire and
temperature. In addition, Roxul products are subject to very
littleshrinkage in the critical phase of a fire, so the insulation
layers remain in place to better prohibit the spread of flame.
Roxul Safe is intended tobe used in conjunction with a fire
sealant to prevent the passage of fire and smoke.
ComplianceandPerformance:
CAN4 -S115M Standard Test Method of Firestop Sytems Complies
ASTM C 612 Mineral Fiber Block and Board Thermal Insulation Type IVA, Complies
MEA Approval NewYork CityApproval 339-97-M
City Of Los Angeles Approval RR25444
ULDesignNos. Consult ULDirectory fornumerousapprovedfireratedjointsystems,throughpenetrationdesigns
andcurtainwalldesignlistings,orcontactRoxulforfurtherinformation.
FirePerformance:
ASTME136 BehaviourofMaterialsat750°C(1382°F) Non-Combustible
CAN4S114 Test forNon-Combustibility Non-Combustible
ASTME84(UL723) SurfaceBurningCharacteristics FlameSpread=0
SmokeDeveloped=0
CAN/ULCS102 SurfaceBurningCharacteristics FlameSpread=0
SmokeDeveloped=0
SmoulderResistance:
CAN/ULC-S129SmoulderResistance 0.01%
MoistureResistance:
ASTM C 1104 Moisture Sorption 0.04%
CorrosiveResistance:
ASTM C 665 Corrosiveness to Steel Pass
ASTM C 795 **** Stainless Steel Stress CorrosionSpecification as per Test Conforms
Methods C871 and C692: U.S. Nuclear Regulatory Commision,
Reg. Guide#1.36: U.S. Military Specifications MIL-I-24244 (all
versions including BandC)
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
*MASTER FORMAT 1995 EDITION **MASTER FORMAT 2004 EDITION
Page 25
AcousticalPerformance
ASTMC423
CO-EFFICIENTSATFREQUENCIES
Thickness125Hz250Hz500Hz1000Hz2000Hz4000HzNRC
2.0 0.26 0.68 1.12 1.10 1.03 1.04 1.00
3.0 0.63 0.95 1.14 1.01 1.03 1.04 1.05
4.0 1.03 1.07 1.12 1.04 1.07 1.08 1.10
CompressiveStrength:
ASTM C 165 at 10% 144 psf (6.9 kPa)
Density:KeyApplication Qualifiers:
ASTM C 612-00 Actual 4.5 lbs/ft³ 72 kg/m³ • Easily cut
• Non-combustible
• Excellent sound absorbency
Dimensions:
• Chemicallyinert
24” (width) x 48” (length)
• Does not rot or sustain vermin
610 mm (width) x 1219 mm (length)
• Does not promote growth of fungi or mildew
• Lowmoisture sorption
Thickness:
• Water resistant
Product thickness is available in 2”, 3” and 4”
• CFC and HCFC free product and process
•Made fromnatural&recycledmaterials
For additional sizes, please contact our customer service
representatives.
Facing:
This product can be faced with reinforced foil facing. Please
note that the facings will influence the product’s service
temperature range.
OtherROXULProducts:
Please consult ROXUL for all your insulation needs. We have
an extensive range of products for all applications from pipe
insulationtocommercialproductstoresidentialbatts.ROXUL
invitesallinquiriesandwillactpromptlytoserviceallofyour
requirements.
****“Provisionsforlot testingmayberequired,consultmanufacturer.”
Note:
AsROXULInc.hasnocontroloverinstallationdesignandworkmanship,accessorymaterialsorapplicationconditions, ROXULInc. doesnot
warrantytheperformanceorresultsof anyinstallationcontainingROXULInc’s.products.ROXUL Inc’s. overallliabilityandtheremedies
availablearelimitedbythegeneral termsandconditionsofsale. Thiswarrantyisinlieuof allotherwarrantiesandconditionsexpressedor
implied,includingthewarrantiesofmerchantabilityandfitnessforaparticularpurpose.
ROXUL INC.Milton,OntarioTel:905-878-8474Fax:905-878-8077
www.roxul.comTel:1-800-265-6878 Fax:1-800-991-0110
Revised:May 25, 2009
Swedish Edmonds ACC
Supersedes: March 10, 2009
Expert Drywall, Inc.
078446 Submittal
Page 26
1.2.D
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 27
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 28
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 29
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 30
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 31
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 32
1.2.D
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 33
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 34
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 35
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 36
1.2.D
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 37
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 38
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 39
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 40
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 41
1.2.D
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 42
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 43
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 44
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 45
1.2.D
BWS 0002
S
S
I
A
F
L
I
System No. BW-S-0002
C
E
D
Assembly Ratings -- 1 and 2 Hr (See Item 1)
CUS
L Rating at Ambient -- Less than 1 CFM/Lin Ft
Classified by
Underwriters Laboratories, Inc.
L Rating at 400° F -- Less than 1 CFM/Lin Ft
to UL 2079 and CAN/ULC-S115
Nominal Joint Width -- 3/4 In.
2B
2C
2A
1
3
1. Floor Assembly -- Min 4-1/2 in. thick reinforced lightweight or normal weight (100-150 pcf) structural concrete. Floor may also be constructed of
any 6 in. thick UL Classified hollow-core Precast Concrete Units*.
See Precast Concrete Units category in the Fire Resistance Directory for names of manufactures.
2. Wall Assembly -- The 1 or 2 h fire-rated gypsum board/steel stud wall assembly shall be constructed of the materials and in the manner specified
in the individual U400 or V400 Series Wall or Partition Design in the UL Fire Resistance Directory. In addition, the wall may incorporate a
head-of-wall joint system as specified in the HW Series Joint Systems in the UL Fire Resistance Directory. The wall shall include the following
construction features:
A. Steel Floor Runners -- Floor runners of wall assembly shall consist of min No. 25 gauge galv steel channels sized to accommodate steel
studs (Item 2B). Floor runners to be provided with 1-1/4 in. flanges. Runners secured with steel fasteners spaced 12 in. OC.
B. Studs -- Steel studs to be min 3-1/2 in. wide. Studs cut 1/2 to 3/4 in. less in length than assembly height with bottom nesting in, resting on and
fastened to floor runner with sheet metal screws. Stud spacing not to exceed 24 in. OC.
C. Gypsum Board* -- Gypsum board installed to a min total thickness of 5/8 or 1-1/4 in. on each side of wall for a 1 or 2 hr rated wall,
respectively. Wall to be constructed as specified in the individual U400 or V400 Series Design in the UL Fire Resistance Directory, except that
a max 3/4 in. gap shall be maintained between the bottom of gypsum board and top of concrete floor. The hourly fire rating of the joint system
is equal to the hourly fire rating of the wall.
3. Fill, Void or Cavity Material* Sealant -- Max separation between top of floor and bottom of wall is 3/4 in. Min 5/8 in. thickness of fill material
installed on each side of the wall between the bottom of the gypsum board and the top of the concrete floor, flush with each surface of the wall. .
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- CP601S Elastomeric Firestop Sealant, CP606 Flexible Firestop Sealant or FS-ONE
Sealant
*Bearing the UL Classification Mark
Reproduced by HILTI, Inc. Courtesy of
Swedish Edmonds ACC
Underwriters Laboratories, Inc.
Expert Drywall, Inc.
June 12, 2003
078446 Submittal
Page 46
1.2.D
BWS 0023
S
S
I
A
F
L
I
System No. BW-S-0023
C
E
D
Assembly Ratings — 1 and 2 Hr (See Item 2)
CUS
Joint Width — 1 in. Max
Classified by
Underwriters Laboratories, Inc.
to UL 1479 and CAN/ULC-S115
2B
2C
2D
2A
3
1
1. Floor Assembly — Min 2-1/2 in. (64 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) structural concrete.
2. Wall Assembly — The 1 or 2 hr fire rated gypsum board/steel stud shaft wall assembly shall be constructed of the materials and in the manner
specified in the individual U400 or V400 Series Wall and Partition Design in the UL Fire Resistance Directory. In addition, the wall may incorporate
a head-of-wall joint system constructed as specified in the HW Series Joint Systems in the UL Fire Resistance Directory. The wall shall include the
following construction features:
A. Floor and Ceiling Runners — J-shaped runner, 2-1/2 in. (64 mm) wide with unequal legs of min 1-1/4 in. (32 mm) and 2 in. (51 mm),
fabricated from min 24 MSG galv steel. Runners positioned with short leg toward finished side of wall. Runners attached to structural supports
with steel fasteners located not greater than 2 in. (51 mm) from ends and not greater than 24 in. (610 mm) OC.
B. Steel Studs — C-H-shaped studs, 2-1/2 in. (64 mm) wide by 1-1/2 in. (38 mm) deep, fabricated from min 25 MSG galv steel, cut to lengths
3/8 to 1/2 in. (10 to 13 mm) less than floor to ceiling height and spaced 24 in. (610 mm) OC. Studs nest in floor runner at bottom and J runner
or slotted ceiling track at top. After installation of gypsum board liner panels (Item 2C), studs secured to flange of floor runner on finished side
of wall only with No. 6 by 1/2 in. (13 mm) long self-drilling, self-tapping steel screws. Studs secured to flange of slotted ceiling track on finished
side of wall only with No. 8 by 1/2 in. (13 mm) long self-drilling, self-tapping wafer head steel screws at slot midheight.
C. Gypsum Board* — 1 in. (25 mm) thick by 24 in. (610 mm) wide gypsum board liner panels as specified in the individual U400 or V400-Series
design. Panels cut 1 in. (25 mm) less in length than floor to ceiling height. Vertical edges inserted in "H"-shaped section of "C-H" studs. At the
ends of the assembly, the free edge of the end panels are attached to the long leg of vertical J-runners (Item 2A) with 1-5/8 in. (41 mm) long
Type S steel screws spaced max 12 in. (305 mm) OC.
D. Gypsum Board* — Gypsum board sheets, 1/2 or 5/8 in. (13 or 16 mm) thick, applied vertically or horizontally in two layers on finished side of
wall as specified in the individual U400 or V400-Series design. A max 1 in. (25 mm) gap shall be maintained between the bottom of the
gypsum board and the top surface of the concrete floor. The screws attaching the gypsum board layers to the C-H studs shall be located 1 in.
(25 mm) above the top of the J-runner or slotted ceiling track. No gypsum board attachment screws are to penetrate the ceiling J-runner and
slotted ceiling track.
The hourly fire rating of the joint system is equal to the hourly fire rating of the wall.
3. Fill, Void or Cavity Material* Sealant — Max separation between top of floor and bottom of gypsum board on the finish side is 1in. The depth of
sealant to be installed to fill the linear gap between the bottom of the gypsum board sheets (Item 2D) and the top of the concrete floor shall be
equal to the overall thickness of the gypsum board sheets, flush with the finished side of the wall.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 606
*Bearing the UL Classification Mark
Reproduced by HILTI, Inc. Courtesy of
Swedish Edmonds ACC
Underwriters Laboratories, Inc.
Expert Drywall, Inc.
May 17, 2010
078446 Submittal
Page 47
Swedish Edmonds ACC
Expert Drywall, Inc.
078446 Submittal
Page 48