078446.001-0 Fire-Resistive_Joint_Systems_NBBJ-PAAN.pdf Page 1of 1 CONTRACTOR SUBMITTAL ISSUE TO NBBJ NBBJ Submittal Number DATE ISSUEDDec 9, 2014 113-078446-0 COMPANYNBBJ GC Submittal Number 113-078446001-0 223 Yale Avenue North Seattle, WA 98109 SPEC. PARAGRAPH: PHONE / FAX(206) 223-5555 Fire-Resistive Joint SPEC. DESCRIPTION: Systems PROJECT NUMBER100822.06 Fire Resistive Joint PROJECT NAMESMC Edmonds ACC SPECIFIC ITEM: Systems ATTENTION:Barb Gipple CONTRACTOR ISSUED ON:Dec 9, 2014 DATE REQUESTED BACK:Dec 23, 2014 DATE RECEIVED @ NBBJ:Dec 9, 2014 DATE DUE BACK TO Dec 23, 2014 CONTRACTOR: DATE RETURNED BY NBBJ: 12/18/14 COPIES ITEMS TRANSMITTED SENT VIA REVIEW ACTIONPartially approved as noted REVIEW NOTE GC REMARKS NBBJ COMPOSITE RESPONSE Entered By: Andris Lapins Entered Date: Thursday, December 18, 2014 2:33 PM Partially approved as noted. Revise & resubmit Level One remodel area per ASI-07. Partially approved as noted. Revise & resubmit Level One remodel area per ASI-07. CONSULTANTS REPRESENTED ISSUED BY Scott Solberg PHONE / FAX:(206) 682-7770 NBBJAndris Lapins NBBJRachel Jenner EMAIL:scott.solberg@sellen.com COPY TO:Dan Schnebele Jenna Shope Mark Bucek ELECTRONIC ATTACHMENTS 0113-078446001-0_Fire-Resistive_Joint_Systems_NBBJ-PAAN.pdf htts://secure1.nbb.com/CATools/Data/SubForm.asx?SubmittalID=127701218201 pjp9//4 1 | Page SUBMITTAL FOR APPROVAL Submittal #: 113 -078446.001 Rev#: 0 7039. - SWEDISH/EDMONDS-AMBULATORY CARE Priority: Medium CENTER Date: 12/09/2014 To: RACHEL JENNER From: SCOTT SOLBERG NBBJ SELLEN CONSTRUCTION CO., INC. 223 Yale Ave 227 WESTLAKE AVE N Seattle, 98109 SEATTLE, WA 98109 Originator: EXPERT DRYWALL INC. Description: Fire Resistive Joint Systems We are transmitting the following Submittal Package item(s) for your review in accordance with the contract specifications. Please review and respond to: SCOTT SOLBERG, by: 12/23/2014. Additional Notes: Item Number Spec Section Description Details Notes 113-001.0 078446 Fire Resistive Joint Systems cc: December 04, Swedish Edmonds Ambulatory Care Center SECTION 078446 NOTE: Partial Submittal Construction Documents FIRE-RESISTIVE JOINT SYSTEMS Expert Drywall is contracted to supply & install 10 June 2014 Joints at the perimeter of GWB assemblies only. No other joints are part of our work. SECTION 078446 - FIRE-RESISTIVE JOINT SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Fire-resistive joint systems in or between fire-resistance-rated constructions including, but not limited to, the following: 1. Joints in or between fire-resistance-rated constructions. 2. Joints at exterior curtain-wall/floor intersections. 3. Joints in smoke barriers. B. Related Sections: 1. 07 8413 - Penetration Firestopping: For systems installed in openings in walls and floors with and without penetrating items. 1.2 SUBMITTALS A. Product Data: For each type of product indicated. See Part 2 B. Product Schedule: For each fire-resistive joint system. Include location and design Pages 6-8 designation of qualified testing agency. 1. Where Project conditions require modification to a qualified testing agency's illustration for a particular fire-resistive joint system condition, submit illustration, with modifications marked, approved by fire-resistive joint system manufacturer's fire-protection engineer as an engineering judgment or equivalent fire-resistance-rated assembly. Will be C.Installer Certificates: From Installer indicating fire-resistive joint systems have been submitted upon installed in compliance with requirements and manufacturer's written completion. recommendations. D.Product test reports. Pages 27-47 1.3 QUALITY ASSURANCE A. Installer Qualifications: A firm experienced in installing fire-resistive joint systems similar in material, design, and extent to that indicated for this Project, whose work has resulted in construction with a record of successful performance. Qualifications include having the necessary experience, staff, and training to install manufacturer's products per specified requirements. Manufacturer's willingness to sell its fire-resistive joint system products to Contractor or to Installer engaged by Contractor does not in itself confer qualification on buyer. B. Fire-Test-Response Characteristics: Fire-resistive joint systems shall comply with the following requirements: 1. Fire-resistive joint system tests are performed by a qualified testing agency acceptable to authorities having jurisdiction. Swedish Edmonds ACC Expert Drywall, Inc. NBBJ Project No. 100822.06 078446 - 1 078446 Submittal Page 01 Swedish Edmonds Ambulatory Care Center SECTION 078446 Construction Documents FIRE-RESISTIVE JOINT SYSTEMS 10 June 2014 2. Fire-resistive joint systems are identical to those tested per testing standard referenced in "Fire-Resistive Joint Systems" Article. Provide rated systems complying with the following requirements: a. Fire-resistive joint system products bear classification marking of qualified testing agency. b. Fire-resistive joint systems correspond to those indicated by reference to designations listed by the following: 1) UL in its "Fire Resistance Directory." 2) Intertek ETL SEMKO in its "Directory of Listed Building Products." 1.4 COORDINATION A. Coordinate construction of joints to ensure that fire-resistive joint systems are installed according to specified requirements. B. Coordinate sizing of joints to accommodate fire-resistive joint systems. C.Notify Owner's testing agency at least seven days in advance of fire-resistive joint system installations; confirm dates and times on day preceding each series of installations. PART 2 - PRODUCTS 2.1 FIRE-RESISTIVE JOINT SYSTEMS A. Where required, provide fire-resistive joint systems that are produced and installed to Acknowledged resist spread of fire according to requirements indicated, resist passage of smoke and other gases, and maintain original fire-resistance rating of assemblies in or between which fire-resistive joint systems are installed. Fire-resistive joint systems shall accommodate building movements without impairing their ability to resist the passage of fire and hot gases. B. Joints in or between Fire-Resistance-Rated Construction: Ratings determined per Pages 11-20 ASTM E 1966 or UL 2079: 1. Fire-Resistance Rating: Equal to or exceeding the fire-resistance rating of construction they will join. 2. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, For head-of-wall joint, but are not limited to, the following: see substitution a. A/D Fire Protection Systems Inc. request on pages b. CEMCO. 9-19. c. Fire Trak Corp. d. Grace Construction Products. For end-of-wall and bottom-of-wall, see e. Hilti, Inc. Hilti, Inc. e. page 20. f. Johns Manville. g. Nelson Firestop Products. h. NUCO Inc. i. Passive Fire Protection Partners. Swedish Edmonds ACC Expert Drywall, Inc. NBBJ Project No. 100822.06 078446 - 2 078446 Submittal Page 02 Swedish Edmonds Ambulatory Care Center SECTION 078446 Construction Documents FIRE-RESISTIVE JOINT SYSTEMS 10 June 2014 j. RectorSeal Corporation. k. Specified Technologies Inc. l. 3M Fire Protection Products. m. Tremco, Inc.; Tremco Fire Protection Systems Group. n. USG Corporation. C.Joints at Exterior Curtain-Wall/Floor Intersections: Provide fire-resistive joint systems N/A consisting of mineral fiber safing and smoke seal compound with rating determined by ASTM E 119 based on testing at a positive pressure differential of 0.01-inch wg (2.49 Pa) or ASTM E 2307. 1. Fire-Resistance Rating: Equal to or exceeding the fire-resistance rating of the floor assembly. 2. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following: a. A/D Fire Protection Systems Inc. b. Grace Construction Products. c. Hilti, Inc. d. Johns Manville. e. Nelson Firestop Products. f. NUCO Inc. g. Passive Fire Protection Partners. h. RectorSeal Corporation. i. Specified Technologies Inc. j. 3M Fire Protection Products. k. Thermafiber, Inc. l. Tremco, Inc.; Tremco Fire Protection Systems Group. m. USG Corporation. D.Joints in Smoke Barriers: Ratings determined per UL 2079. Pages 21-24 1. L-Rating: Not exceeding 5.0 cfm/ft (0.00775 cu. m/s x m) of joint at 0.30 inch wg (74.7 Pa) at both ambient and elevated temperatures. 2. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following: a. A/D Fire Protection Systems Inc. b. Grace Construction Products. See note c. Hilti, Inc. Hilti 506 gun-grade will be used at the base/ends of walls Hilti, Inc.Hilti, Inc.Hilti, Inc. c. at right where there is a small and uniform joint. d. Johns Manville. Hilti 572 spray grade will be used with mineral wool backer e. Nelson Firestop Products. at the top of wall and other large/irregular voids f. NUCO Inc. g. Passive Fire Protection Partners. h. RectorSeal Corporation. i. Specified Technologies Inc. j. 3M Fire Protection Products. k. Tremco, Inc.; Tremco Fire Protection Systems Group. l. USG Corporation. Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal NBBJ Project No. 100822.06 078446 - 3 Page 03 Swedish Edmonds Ambulatory Care Center SECTION 078446 Construction Documents FIRE-RESISTIVE JOINT SYSTEMS 10 June 2014 Pages 12&20 E. Exposed Fire-Resistive Joint Systems: Provide products with flame-spread and smoke-developed indexes of less than 25 and 450, respectively, as determined per ASTM E 84. Pages 25&26 F. Accessories: Provide components of fire-resistive joint systems, including primers and forming materials, that are needed to install fill materials and to maintain ratings required. Use only components specified by fire-resistive joint system manufacturer and approved by the qualified testing agency for systems indicated. PART 3 - EXECUTION 3.1 INSTALLATION A. Examine substrates and conditions, with Installer present, for compliance with Acknowledged requirements for joint configurations, substrates, and other conditions affecting performance of the Work. B. Install fire-resistive joint systems to comply with manufacturer's written installation Acknowledged instructions and published drawings for products and applications indicated. C.Install forming materials and other accessories of types required to support fill Acknowledged materials during their application and in position needed to produce cross-sectional shapes and depths required to achieve fire ratings indicated. 1. After installing fill materials and allowing them to fully cure, remove combustible forming materials and other accessories not indicated as permanent components of fire-resistive joint system. D.Install fill materials for fire-resistive joint systems by proven techniques to produce the Acknowledged following results: 1. Fill voids and cavities formed by joints and forming materials as required to achieve fire-resistance ratings indicated. 2. Apply fill materials so they contact and adhere to substrates formed by joints. 3. For fill materials that will remain exposed after completing the Work, finish to produce smooth, uniform surfaces that are flush with adjoining finishes. We believe that the identification provided by specification section 070553 fulfills 3.2 IDENTIFICATION this requirement. If the intent of this specification is to provide signage in addition to 070553, please advise regarding the location and spacing of these signs. See note A. Identify fire-resistive joint systems with preprinted metal or plastic labels. Attach at right labels permanently to surfaces adjacent to and within 6 inches (150 mm) of joint edge so labels will be visible to anyone seeking to remove or penetrate joint system. Use mechanical fasteners or self-adhering-type labels with adhesives capable of permanently bonding labels to surfaces on which labels are placed. Include the following information on labels: 1. The words "Warning - Fire-Resistive Joint System - Do Not Disturb. Notify Building Management of Any Damage." NBBJ: 070553 LABELING IS FOR RATED 2. Contractor's name, address, and phone number. PARTITIONS SATSIFYING IBC 703.7. LABELING 3. Designation of applicable testing agency. PER 078446, 3.2 IS INTENDED TO IDENTIFY 4. Date of installation. SPECIFIC FIRE-RESISTIVE JOINT SYSTEMS Swedish Edmonds ACC USED AT ANY SPECIFIC LOCATION. Expert Drywall, Inc. REQUIREMENT STANDS. NOT NECESSARY 078446 Submittal NBBJ Project No. 100822.06 078446 - 4 HOWEVER, AT BASE OF WALL CONDITIONS IN Page 04 FINISHED SPACES. MAXIMUM SPACING 30' AND WITHIN 15' OF CORNERS. Swedish Edmonds Ambulatory Care Center SECTION 078446 Construction Documents FIRE-RESISTIVE JOINT SYSTEMS 10 June 2014 5. Manufacturer's name. 6. Installer's name. 3.3 FIELD QUALITY CONTROL Acknowledged A. Inspecting Agency: Owner will engage a qualified testing agency to perform tests and inspections. Acknowledged B. Where deficiencies are found or fire-resistive joint systems are damaged or removed due to testing, repair or replace fire-resistive joint systems so they comply with requirements. C.Proceed with enclosing fire-resistive joint systems with other construction only after Acknowledged inspection reports are issued and installations comply with requirements. END OF SECTION Swedish Edmonds ACC Expert Drywall, Inc. NBBJ Project No. 100822.06 078446 - 5 078446 Submittal Page 05 Expert Drywall, Inc. December 04, 2014 F & S RATINGS UP URGENT CARE SUITE 1P119' - 0"UP OCC. LOAD - 54 5377 SF ASSEMBLY CEILING 1hr Shaftwall NBBJ: SMOKE FEC Ceiling Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal FEC Page 06 2hr Shaftwall Ceiling ED SUITE - EAST OCC. LOAD - 99 9884 SF FEC FEC 1hr Shaftwall FEC FEC COMPARTMENT 1C Ceiling ED SUITE - WEST LOBBY SMOKE OCC. LOAD - 150 OCC. LOAD - 96 14984 SF 9593 SF UP FEC UP FEC ASSEMBLY CEILING NBBJ: SMOKE FEC IMAGING SUITE OCC. LOAD - 57 FEC RESUBMIT REMODEL AREA PER ASI-07. FEC 5703 SF NBBJ: REVISE & Hilti 572 spray grade will be used with mineral wool backer at the Head-of-Wall per Team Design dated October 23, 2014 (page 48) Dashed line indicates wall terminates at rated ceiling - no Hilti 506 gun-grade will be used at the base/ends of walls where FEC G FEC Special 2 HR Fire-Resistive Assembly for Gypsum Shaftwall G 1 or 2 HR Fire-Resistive Assembly for Gypsum Wallboard F 2 HR Fire-Resistive Assembly for Gypsum Shaftwall F F E head-of-wall design is needed for this area. top of wall and other large/irregular voids FEC UL Design HW-D-499, 500 or 513 Bottom-of-Wall UL Design BW-S-002 E Bottom-of-Wall UL Design BW-S-023 Bottom-of-Wall UL Design BW-S-023 there is a small and uniform joint. Head-of-Wall UL Design HW-D-504 D FEC C O R RI D OR FEC D A U TO EM QUA ITE P.D R O SO TM AI R C OBSERVATION OCC. LOAD - 58 (REMODEL) 5744 SF C O RR ID O R Smoke Assembly C O R R ID O R C VE S TI B UL E B V E S JATIB NU ITL OE R W OM E N TOS IL' E T D MN E N S' TO IL E T ' A DC AON RKT RRO OAL OR MEA X- R A RY O O M FEC X - R A RY O O M A B TO IL E T A LC O V FEC E D RE S S . G O W N H & AM P E R D RE S 3 S .T AO LCIL OET V E 2 . 2 D RE S S . 2 T O ILE T 1 Head-of-Wall per Team Design dated October 23, 2014 (page 48) Dashed line indicates wall terminates at rated ceiling - no Hilti 506 gun-grade will be used at the base/ends of walls where D N D N ISSUE MARKDATEDESCRIPTION Expert Drywall, Inc. December 04, 2014 F & S RATINGS Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal UP Page 07 FEC OCC. LOAD - 211 (FUTURE) COMPARTMENT 2A 21057 SF SMOKE FEC FEC Hilti 572 spray grade will be used with mineral wool backer at the Hilti 506 gun-grade will be used at the base/ends of walls where 1 or 2 HR Fire-Resistive Assembly for Gypsum Wallboard 2 HR Fire-Resistive Assembly for Gypsum Shaftwall top of wall and other large/irregular voids UL Design HW-D-499, 500 or 513 Bottom-of-Wall UL Design BW-S-002 Bottom-of-Wall UL Design BW-S-023 there is a small and uniform joint. Head-of-Wall UL Design HW-D-504 FEC Smoke Assembly Head-of-Wall UL Design HW-D-504 Hilti 506 gun-grade will be used at the base/ends of walls where Expert Drywall, Inc. December 04, 2014 F & S RATINGS Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 08 Hilti 572 spray grade will be used with mineral wool backer at the Hilti 506 gun-grade will be used at the base/ends of walls where 1 or 2 HR Fire-Resistive Assembly for Gypsum Wallboard 2 HR Fire-Resistive Assembly for Gypsum Shaftwall top of wall and other large/irregular voids UL Design HW-D-499, 500 or 513 Bottom-of-Wall UL Design BW-S-002 Bottom-of-Wall UL Design BW-S-023 there is a small and uniform joint. Head-of-Wall UL Design HW-D-504 Smoke Assembly 2 HR Fire-Resistive Assembly for Gypsum Shaftwall Smoke Assembly 1 or 2 HR Fire-Resistive Assembly for Gypsum Wallboard SUBSTITUTION FOR CONVENIENCE: Requested substitution offers the following SECTION 01 2501 Swedish Edmonds Ambulatory Care Center Construction Documents SUBSTITUTION REQUEST FORM 10 June 2014 Substitution Request Number: TO: NBBJ, 223 Yale Avenue North, Seattle WA 98109. Attn: FROM: Expert Drywall, Inc. Specification Section: 078446 Fire-Resistive Joint Systems Article and Paragraph(s): 2.6.B. Joints in or between Fire-Resistance-Rated Construction Fire-resistive joint treatment - 14 manufacturers listed Specified Item: Proposed Substitution: Fire-resistive joint treatment - manufactured by BlazeFrame, which was not one of the specified manufacturers, but is similar to CEMCO's product. SUBSTITUTION FOR CAUSE: Required due to change in project conditions as follows: Unavailability of Product: Unsuitability: Regulatory Change: Unavailability of Required Warranty: SUBSTITUTION FOR CONVENIENCE: Requested substitution offers the following SUBSTITUTION FOR CONVENIENCE: Requested substitution offers the following substantial advantage(s) to Owner: Cost (Dollar Amount): None. Time (Days): Expert's scope will install faster and is not affected by weather Energy Conservation (Dollar Amount): None. Other (Explain): None. Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal NBBJ Project No. 100822.06 01 2501 - 1 Page 09 SECTION 01 2501 Swedish Edmonds Ambulatory Care Center Construction Documents SUBSTITUTION REQUEST FORM 10 June 2014 The Undersigned certifies that: Proposed substitution meets requirements stipulated in Section 01 2500 - Substitution Procedures. Required documentation for proposed substitution is provided in accordance with Sec- Required documentation for proposed substitution is provided in accordance with Sec- tion 01 2500 - Substitution Procedures. tion 01 2500 - Substitution Procedures. Proposed substitution has been fully investigated and determined to be equal or superior to specified item. Same warranty will be furnished for proposed substitution as for specified item. Proposed substitution will have no adverse effect on other Work and will not affect or de- lay progress schedule. Cost data stated is complete. Claims for additional costs related to accepted substitution which may subsequently become apparent are waived. Proposed substitution does not affect dimensions and functional clearances. CERTIFICATION OF EQUAL PERFORMANCE AND ASSUMPTION OF LIABILITY FOR EQUAL PERFORMANCE Submitted By (Contractor):_______________________________________________________ Expert Drywall, Inc. Signature __________________________________________________ Date _____________ Nov 24, 2014 Printed Name and Title _________________________________________________________ Mark Leavitt, Project Manager Signature must be by person having authority to legally bind his firm to the above terms. Failure to provide legally binding signature will result in retraction of approval ARCHITECT'S REVIEW AND ACTION X ____Substitution Approved ____Substitution Approved as Noted ____Substitution Rejected Andris Lapins 12/18/14 Signature: ____________________________________________________ Date ___________ Andris Lapins, Senior Associate, NBBJ Printed Name and Title __________________________________________________________ Additional Comments: _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ END OF SECTION Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal NBBJ Project No. 100822.06 01 2501 - 2 Page 10 Swedish Edmonds ACC BlazeFrame Ind. Expert Drywall, Inc. 8805 NE 148Ave NE th 078446 Submittal Redmond, WA Page 11 425-869-2811 www.blazeframe.com Project Submittal – Basic Coated Metal Deck 1. Product Description 3. Testing Data A strip of highly intumescent It has been tested as a dynamic and static fire stop material affixed to metal profiles joint protection fire stop sealant to ASTM E- When exposed to heat, this product 814, UL 1479, and UL 2079. Complies to expands and forms a hard char to seal Required Environmental Exposure Testing off joint (gap) preventing passage of flames, of Accelerated Aging and High Humidity as temperature pass through, and hot gases. per UL 1479 Fire Test of Through- Penetration Firestops. 2. Material Properties Degree of intumescence per DIN standard Asbestos Fillers: None 18x with weight imposed Solvents: None 37x free intumescing Hazardous Ingredients: None Thickness: 2 mm ASTM E 84, UL 723 Tunnel Test ASTM E 84, UL 723 Tunnel Test Width: Per BlazeFrame Profile Flame Spread 5 Flame Spread 5 Activation of Intumescence: Smoke Index 5 Smoke Index 5Smoke Index 5 2.1.E Expansion Begins 375 F (190C) Expansion Greatest 575 (302 C) to 1100 F (593 C) Color: Black Exposed Surface: Poly Coating Freeze-Thaw: Excellent Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 12 12 www.blazeframe.com 0±®£´¢³ 0±®¥¨«¤ $¨¬¤­²¨®­² PS5 - - Composite Fire Stop/Framing for use in up to 3 hr rated wall assemblies, movement with level III (seismic) certification. Minimum G40 (20ga) and G60 (18ga and hstuds per listed assemblies spray fire proofing. (G) (I) (L1) (S) Patented 1.00" .25" Fastener mid-height of exposed slot Part Identification Widths (W) Mil (Ga) 250 (2 1/2").030 (20) 362SLCD2 - 30 Example: 362 (3 5/8") .033 (20) - 362SLCD230 400 (4") .043 (18) 600 (6").054 (16) 800 (8").068 (14)Series Track Width Gauge Profile 1 - Series (Fire Stop One Side)2 - Series (Fire Stop Both Sides) (W)(W) (G) (G) (L2)(L2) (L1) (L1) GapSlotted Leg LengthSolid Leg Length Profile Joint Strip WidthSlot Height (G)Protection (L1)(L2) (I)(S) SLCD.50" 1.00" 3.00"2.00"1.50" .75" .50" SLWCD3.25"2.00"1.50" 1.00" 1.25" SLXCD .50"4.25"2.50"2.00" 1.50" 1.75" UL, ASTM & Code StandardsLeed Points UL2079, E814, E1966, ULC S115-M95 MR 2.1 & 2.2 - Construction Waste: up to 2pts UL207 9, E814, E1966, ULC S115 ASTM E814, E1966 MR 4.1 & 4.2 - Recycled Content: up to 2 pts A1003, A653, A924, C645, C754, C955 MR 5.1 & 5.2 - Regional Proximity AISI 2004 NAS EQ 4.1 - Low Emitting Materials 2009 IBC & 2013 CBC EQ 9 - Enhanced Acoustical Swedish Edmonds ACC Expert Drywall, Inc. ¶¶¶ȁ¡« ¹¤¥± ¬¤ȁ¢®¬ 2.1.B 078446 Submittal 0§®­¤Ȁ ȨΓΑΔȩ ΗΕΘȃΑΗΐΐ & ·Ȁ ȨΓΑΔȩ ΗΕΘȃΑΒΏΏ Page 13 0±®£´¢³ 0±®¥¨«¤ $¨¬¤­²¨®­² PS49 - Slotted J-Runner Profiles one slotted and one solid leg Composite Fire Stop/Framing for use in up to 2 hr rated movement with level III (seismic) certification. Minimum G40 (20ga) and G60 (18ga and heavier) coating having studs per . listed assemblies in UL Fire Resistance Directory (I) (L1) (S) Patented .25" 1.00" Fastener mid-height of exposed slot Mil (Ga) Widths (W) Part Identification 250 (2 1/2").030 (20) Example: 400JRS-30 400 (4") .033 (20) - 30 400JRS .043 (18) 600 (6") .054 (16) Track Width Gauge Profile (W) (L2) (L1) ProfileSlotted Leg LengthSolid Leg LengthStrip WidthJoint Slot Height (L1)(L2)Protection (I)(S) 2.50"1.00" JRSE3.00".75".50" 1.00" .75" JRS3.00"3.00"1.50" 1.00" 3.00" JRSW3.00"1.25"1.50" 4.00" JRSX2.00"1.50" 3.00"1.75" UL, ASTM & Code StandardsLeed Points UL2079, E814, E1966, ULC S115-M95 MR 2.1 & 2.2 - Construction Waste: up to 2pts UL2079, E814, E1966, ULC S115 A1003, A653, A924, C645, C754, C955 MR 4.1 & 4.2 - Recycled Content: up to 2 pts AISI 2004 NAS MR 5.1 & 5.2 - Regional Proximity 2006 & 2009 IBC EQ 4.1 - Low Emitting Materials 2013 CBC EQ 9 - Enhanced Acoustical Swedish Edmonds ACC ¶¶¶ȁ¡« ¹¤¥± ¬¤ȁ¢®¬ Expert Drywall, Inc. 2.1.B 0§®­¤Ȁ ȨΓΑΔȩ ΗΕΘȃΑΗΐΐ & ·Ȁ ȨΓΑΔȩ ΗΕΘȃΑΒΏΏ 078446 Submittal Page 14 DžɝɚɕɐɎɟ LjɠɍɘɔɟɟɌɗ ƸɚɌɟɐɏ ƹɐɎɖ Ɍəɏ ƸɚɌɟɐɏ ƷɐɌɘɞ Fastener Attachment 24" O/C max. Fastener Attachment 24" O/C max. Fire Proofing or Mineral Wool Installed Gap BlazeFrame Composite (See Notes) Installed Gap Track/Fire Stop (See Notes) BlazeFrame Composite 1" to 4"Composite Track/Fire Stop (See Notes)"CD" Profile 1" to 4" (See Notes) 4 pcf Mineral Wool compressed 33% Steel Stud Max 24" O/C 3 Layers for1" Shaft Fastener below Liner Board 3 Hour Rating Obstruction (when exists) CH, CT, or I stud Max 24" O/C 5/8" Type X 5/8 Type X Gypsum Wallboard Gypsum Wallboard Perpendicular Flute & Parallel Beam Shaft Wall Perpendicular & Parallel Beam 1 2 BlazeFrame Det. PD1 BlazeFrame Det. PD6 UL Ref. HW-D-0512 UL Ref. HW-D-0504 & 0512 Fastener Attachment 24" O/C max.Fire Proofing Fastener Attachment 16" O/C max.Fastener Attachment 24" O/C max. Fire Proofing Installed Gap Installed Gap (Thickness by Others) (See Notes) (See Notes) BlazeFrame Composite BlazeFrame (FC) Track/Fire Stop Flute Cover 1" to 4" 1" to 4" ("CD" Profile) (See Notes) (See Notes) BlazeFrame Composite Track/Fire Stop "CD" Profile Steel Stud Steel Stud 5/8" Type X Max 24" O/C Max 24" O/C 5/8" Type X Gypsum Wallboard Gypsum Wallboard Centered Under Flute - Flute Cover Centered Under Valley 3 4 BlazeFrame Det. PD3 BlazeFrame Det. PD5 UL Ref. HW-D-0512 & 0544 UL Ref. HW-D-0499 & 0512 Metal Pan Deck Fireproofing Metal Pan Deck Structural Steel Support Angle or Z-clip Fire Proofing centered track frame and attached to beam or Steel Track Frame BlazeFrame Composite Track/Fire Stop BlazeFrame Composite Fire Proofing or Installed Gap per Track/Sealant Mineral Wool only Deflection Requirements encompass angle or z-clip"OL" - Series Steel Stud width of wall framing Max 24" O/C 5/8 Type X Gypsum Wallboard Partition per Schedule Swedish Edmonds ACC Under Beam - Offset Leg Beam Penetration 5 6 Expert Drywall, Inc. BlazeFrame Det. SS2 BlazeFrame Det. PD13 078446 Submittal UL Ref. HW-D-0502 UL Ref. HW-D-0495 & 0512 Page 15 ͎ ɢɢɢ̔ɍɗɌɥɐɑɝɌɘɐ̔Ɏɚɘ DžɝɚɕɐɎɟ LjɠɍɘɔɟɟɌɗ ƸɚɌɟɐɏ ƹɐɎɖ Ɍəɏ ƸɚɌɟɐɏ ƷɐɌɘɞ Metal Pan Deck Min. 14ga strap/angle Metal Pan Deck Fastener Attachment Structural Steel Support Structural Steel 24" O/C max. Support Fire Proofing Fire Proofing Installed Gap per BlazeFrame Composite BlazeFrame Composite Deflection Requirements Track/Sealant Track/Sealant "OL" - Series "OL" - Series Installed Gap per Deflection Requirements Partition per Schedule Partition per Schedule Shaft Wall Under Beam - Offset Leg Cantilevered Under Beam - Offset Leg 8 7 BlazeFrame Det. SS4 BlazeFrame Det. SS28 UL Ref. HW-D-0631 UL Ref. HW-D-0502 Metal Pan Deck Structural Steel Support Metal Pan Deck Structural Steel Support Fire Proofing Z-Clip Attachment Clips Z-Clip Attachment Clips Fire Proofing Installed Gap per Installed Gap per 4 pcf Mineral Wool Deflection Requirements BlazeFrame Composite compressed 33% Deflection Requirements Track/Sealant BlazeFrame Composite Track/Sealant Partition per Partition per Schedule Schedule Shaft Wall Under Beam - Z-Clips Under Beam - Z-Clips 10 9 BlazeFrame Det. SS20 BlazeFrame Det. SS16 UL Ref. HW-D-0631 UL Ref. HW-D-0502 Mineral Wool Compressed 33% Fastener Attachment intoFastener Attachment into Mineral Wool Z-Clip Outrigger 16" O/CZ-Clip Outrigger 16" O/C Compressed 33% Z-Clip OutriggerZ-Clip Outrigger BlazeFrameBlazeFrame "ISA" Profile "ISA" Profile Installed Gap per Installed Gap per Deflection Requirements Deflection Requirements BlazeFrame Composite BlazeFrame Composite Track/Sealant Track/SealantPartition per Partition per Schedule Schedule Swedish Edmonds ACC Parallel Beam >24" - Z-Clips/Drywall Rips Parallel Beam >24" - Z-Clips/Drywall Rips 12 11 Expert Drywall, Inc. BlazeFrame Det. SS23 BlazeFrame Det. UD26 078446 Submittal UL Ref. HW-D-0597 UL Ref. HW-D-0597/0504 Page 16 ͏ ɢɢɢ̔ɍɗɌɥɐɑɝɌɘɐ̔Ɏɚɘ DžɝɚɕɐɎɟ LjɠɍɘɔɟɟɌɗ ƸɚɌɟɐɏ ƹɐɎɖ Ɍəɏ ƸɚɌɟɐɏ ƷɐɌɘɞ Fastener Attachment 24" O/C max. Fire Proofing Mineral Wool Installed Gap per Compressed 33% Installed Gap Deflection Requirements (See Notes) BlazeFrame Composite Track/Firestop BlazeFrame Composite "CD" Profile 1" to 4" (See Notes) Track/Sealant Gusset Plate Brace Studs 5/8" Type X Partition per Diagonal Bracing Gypsum Wallboard Steel Stud Schedule Structural Steel Max 24" O/C Chase Wall - Diagonal Bracing Chase Wall - Perpendicular 14 13 BlazeFrame Det. PD2 BlazeFrame Det. SS33 UL Ref. HW-D-0506 UL Ref. HW-D-0506 & 0512 Fire Proofing Fastener Attachment 24" O/C max. 25ga Hat Channel 16" O.C. to Support Drywall Spans Over 16" Drywall Control Joint (Optional) Installed Gap (See Notes) 1" to 4" BlazeFrame Composite (See Notes) Installed Gap per Control Joint Track/Fire Stop (Optional) Deflection Requirements "CD" Series Steel Stud BlazeFrame Composite Max 24" O/C Track/Sealant Fastener at Bottom Partition per of Obstruction Schedule 5/8" Type X (when exists) Gypsum Wallboard Stair Shaft Beam - Control Joint Stair Shaft - Control Joint 16 15 BlazeFrame Det. SS5 BlazeFrame Det. PD7 UL Ref. HW-D-0502/0543 UL Ref. HW-D-0512 & 0543 Fire Proofing Fastener Attachment 24" O/C max. Fire Proofing 25ga Hat Channel 16" O.C. to Support Drywall Spans Over 16" Installed Gap Z-Clip Attachment Clip (See Notes) (16" O/C)Control Joint BlazeFrame Composite (Optional) Composite Track/Fire Stop 1" to 4" "CD" Profile (See Notes) Installed Gap per Deflection Requirements BlazeFrame Composite Track/Sealant Partition per 5/8" Type X Steel Stud ScheduleGypsum Wallboard Max 24" O/C Swedish Edmonds ACC Stair Shaft Beam Z-Clips - Control Joint Offset Under Valley - Mineral Wool 18 17 Expert Drywall, Inc. BlazeFrame Det. SS18 BlazeFrame Det. PD4 078446 Submittal UL Ref. HW-D-0502/0543 UL Ref. HW-D-0499 & 0512 Page 17 ͐ ɢɢɢ̔ɍɗɌɥɐɑɝɌɘɐ̔Ɏɚɘ DžɝɚɕɐɎɟ LjɠɍɘɔɟɟɌɗ ƸɚɌɟɐɏ ƹɐɎɖ Ɍəɏ ƸɚɌɟɐɏ ƷɐɌɘɞ Concrete Column/Wall Fastener Attachment 24" O/C Max. 5/8" Type X Gypsum Wallboard Installed Gap per Deflection Requirements BlazeFrame Composite Track/Sealant "RCS" Profile Steel Stud 3" from Resilient Channel BlazeFrame Profile 1/2" distance from stud to drywall Partition per BlazeFrame "VT" Profile Schedule Installed Gap (see notes) Sound Wall - Resilient Channel Vertical Joint - Concrete 20 19 BlazeFrame Det. VM11 BlazeFrame Det. VM1 UL Ref. HW-D-0498 UL Ref. WW-S-0055 Fire Proof Coating BlazeFrame Composite Track/Sealant Structural Steel Column Steel Stud 3" from BlazeFrame Profile Partition per Installed Gap Schedule max. 3/4" distance Vertical Joint - I-Beam 21 BlazeFrame Det. VM3 UL Ref. WW-S-0055/HW-D-0558 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 18 ͑ ɢɢɢ̔ɍɗɌɥɐɑɝɌɘɐ̔Ɏɚɘ DžɝɚɕɐɎɟ LjɠɍɘɔɟɟɌɗ ƸɚɌɟɐɏ ƹɐɎɖ Ɍəɏ ƸɚɌɟɐɏ ƷɐɌɘɞ BlazeFrame Benefits BlazeFrame Tested Wall Assemblies Intumescent "gasket" Joint Protection 1/2" to 3/4" Exposed Deflection Gaps Direct Attachment - No Caulk at Substrate 5/8" Type X Gypsum Sheathing Reduced Sound Transfer - No Exposed Steel 3 1/2" Fiberglass Insulation Cavity Fill Exposed Head of Wall and Deflection Gaps Level III Dynamic Cycle (seismic) Rated No Joint Fatigue - Lifetime Indefinite Protection NVLAP accredited -ASTM E90-04 Western Electro- Acoustic Laboratory Reports Available Upon Request STC - 52 STC - 56 Unbalanced - (Report # TL 13-223) Balanced - (Report #TL 13-229) STC - 67 STC - 66 Balanced - (Report #TL 13-230) Unbalanced - (Report #TL 13-229) Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 19 ͕ ɢɢɢ̔ɍɗɌɥɐɑɝɌɘɐ̔Ɏɚɘ Product Information 2.1.B.2.e Flexible Firestop Sealant (CP 606) Introduction Product description Product features Paintable Applications and Products Technical Data* CP 606 Chemical basis Color Application temperature and Coatings Skin-forming time Areas of application Curing time Average volume shrinkage (ASTM C1241) Movement capability Selector Guide Temperature resistance Cable bundles 2.1.E Surface burning characteristics (ASTM E 84-96) For use with (ASTM E 90-99) Tested in accordance with Examples Through-Penetration Installation instructions for CP 606 Notice Storage Not for use JOINT Joint Opening Application of firestop DUCT Reference Data Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Hilti. Outperform. Outlast. Page 20 www.us.hilti.com Product Information CP 506 CP 506 CP 506 Smoke and Acoustic Sealant Smoke and Acoustic Sealant Applications Advantages Tested in accordance with: ASTM E 90 Technical DataCP 506 Color Chemical basis Storage and transport temperature range Curing time (73°F / 50% relative humidity) Skin-forming time (73°F / 50% relative humidity) Application temperature range ASTM E 90. Shelf life Volume shrinkage (ASTM E90) ASTM C 834 Movement capability (ISO 11600) Mold and mildew (ASTM G21) Surface burning characteristics 2.1.D.1 (ASTM E84) Air leakage Air leakage DescriptionPackage ContentsItem No. CP 506 smoke and acoustic sealant (580 ml foil pack) CP 506 smoke and acoustic sealant (5 gallon pail) Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Hilti. Outperform. Outlast. Page 21 Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.comwww.hilti.ca 11/2009 Product Information General guidelines for Through-Penetration common acoustic / smoke seal applications Note Top of Wall System STC = 63 Bottom of Wall System STC = 63 System STC = 63 Installation instructions for CP 506 Notice Application of sealantNot for use Storage Opening Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Hilti. Outperform. Outlast. Page 22 Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.comwww.hilti.ca 11/2009 Product Information CP 572 CP 572 CP 572 Smoke and Acoustic Spray Smoke and Acoustic Spray Applications Advantages Technical DataCP 572 Color Chemical basis Storage and transport temperature ASTM E 90. range Curing time approx. (73°F / 50% relative humidity) Skin-forming time (73°F / 50% relative humidity) Application temperature range Shelf life (ASTM E90-99) Surface burning characteristics (ASTM E84) Movement capability Mold and mildew (ASTM G21) DescriptionPackage ContentsItem No. CP 572 smoke and acoustic spray (5 gallon pail) Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Hilti. Outperform. Outlast. Page 23 Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.comwww.hilti.ca 11/2009 Product Information General guidelines for common acoustic / smoke seal applications Top of Wall Note System STC = 54 Installation instructions for CP 572 Notice Application of sprayNot for use Storage Opening Swedish Edmonds ACC Expert Drywall, Inc. Hilti. Outperform. Outlast. 078446 Submittal Page 24 Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.comwww.hilti.ca 11/2009 2.1.F TechnicalProductInformation INSULATION 07840* FIBROUS FIRE SAFING 07 84 56.13** CURTAIN WALL & GLAZED ASSEMBLIES 08 44 00** GeneralProductInformation:Description&CommonApplications: ROXUL® products are mineral wool fibre insulations made ROXULSafe®productisanon-combustible,lightweightand from basalt rock and slag. This combination results in a non-waterrepellentsemi-rigidinsulationbatt thatprovidesfire combustible product with a melting point of approximately stoppingandacousticalinsulationproperties. Specifically 2150°F (1177°C), which gives it excellent fire resistance engineered and produced as a fire stopping material for properties.ROXULmineralwoolisawaterrepellentyet commercial, industrial and residential buildings, Roxul Safe vapourpermeablematerial.canbe used for the following applications: - perimeter gaps between concrete floor slabs and exterior wall systems, - around conduit pipe and duct openings through walls and floor slabs, - between fire walls and ceiling slabs. This product has excellent fire performance properties, such ashigh melt temperature and low thermal conductivity which means the insulation acts as a shield against fire and temperature. In addition, Roxul products are subject to very littleshrinkage in the critical phase of a fire, so the insulation layers remain in place to better prohibit the spread of flame. Roxul Safe is intended tobe used in conjunction with a fire sealant to prevent the passage of fire and smoke. ComplianceandPerformance: CAN4 -S115M Standard Test Method of Firestop Sytems Complies ASTM C 612 Mineral Fiber Block and Board Thermal Insulation Type IVA, Complies MEA Approval NewYork CityApproval 339-97-M City Of Los Angeles Approval RR25444 ULDesignNos. Consult ULDirectory fornumerousapprovedfireratedjointsystems,throughpenetrationdesigns andcurtainwalldesignlistings,orcontactRoxulforfurtherinformation. FirePerformance: ASTME136 BehaviourofMaterialsat750°C(1382°F) Non-Combustible CAN4S114 Test forNon-Combustibility Non-Combustible ASTME84(UL723) SurfaceBurningCharacteristics FlameSpread=0 SmokeDeveloped=0 CAN/ULCS102 SurfaceBurningCharacteristics FlameSpread=0 SmokeDeveloped=0 SmoulderResistance: CAN/ULC-S129SmoulderResistance 0.01% MoistureResistance: ASTM C 1104 Moisture Sorption 0.04% CorrosiveResistance: ASTM C 665 Corrosiveness to Steel Pass ASTM C 795 **** Stainless Steel Stress CorrosionSpecification as per Test Conforms Methods C871 and C692: U.S. Nuclear Regulatory Commision, Reg. Guide#1.36: U.S. Military Specifications MIL-I-24244 (all versions including BandC) Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal *MASTER FORMAT 1995 EDITION **MASTER FORMAT 2004 EDITION Page 25 AcousticalPerformance ASTMC423 CO-EFFICIENTSATFREQUENCIES Thickness125Hz250Hz500Hz1000Hz2000Hz4000HzNRC 2.0 0.26 0.68 1.12 1.10 1.03 1.04 1.00 3.0 0.63 0.95 1.14 1.01 1.03 1.04 1.05 4.0 1.03 1.07 1.12 1.04 1.07 1.08 1.10 CompressiveStrength: ASTM C 165 at 10% 144 psf (6.9 kPa) Density:KeyApplication Qualifiers: ASTM C 612-00 Actual 4.5 lbs/ft³ 72 kg/m³ • Easily cut • Non-combustible • Excellent sound absorbency Dimensions: • Chemicallyinert 24” (width) x 48” (length) • Does not rot or sustain vermin 610 mm (width) x 1219 mm (length) • Does not promote growth of fungi or mildew • Lowmoisture sorption Thickness: • Water resistant Product thickness is available in 2”, 3” and 4” • CFC and HCFC free product and process •Made fromnatural&recycledmaterials For additional sizes, please contact our customer service representatives. Facing: This product can be faced with reinforced foil facing. Please note that the facings will influence the product’s service temperature range. OtherROXULProducts: Please consult ROXUL for all your insulation needs. We have an extensive range of products for all applications from pipe insulationtocommercialproductstoresidentialbatts.ROXUL invitesallinquiriesandwillactpromptlytoserviceallofyour requirements. ****“Provisionsforlot testingmayberequired,consultmanufacturer.” Note: AsROXULInc.hasnocontroloverinstallationdesignandworkmanship,accessorymaterialsorapplicationconditions, ROXULInc. doesnot warrantytheperformanceorresultsof anyinstallationcontainingROXULInc’s.products.ROXUL Inc’s. overallliabilityandtheremedies availablearelimitedbythegeneral termsandconditionsofsale. Thiswarrantyisinlieuof allotherwarrantiesandconditionsexpressedor implied,includingthewarrantiesofmerchantabilityandfitnessforaparticularpurpose. ROXUL INC.Milton,OntarioTel:905-878-8474Fax:905-878-8077 www.roxul.comTel:1-800-265-6878 Fax:1-800-991-0110 Revised:May 25, 2009 Swedish Edmonds ACC Supersedes: March 10, 2009 Expert Drywall, Inc. 078446 Submittal Page 26 1.2.D Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 27 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 28 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 29 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 30 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 31 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 32 1.2.D Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 33 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 34 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 35 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 36 1.2.D Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 37 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 38 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 39 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 40 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 41 1.2.D Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 42 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 43 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 44 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 45 1.2.D BWS 0002 S S I A F L I System No. BW-S-0002 C E D Assembly Ratings -- 1 and 2 Hr (See Item 1) CUS L Rating at Ambient -- Less than 1 CFM/Lin Ft Classified by Underwriters Laboratories, Inc. L Rating at 400° F -- Less than 1 CFM/Lin Ft to UL 2079 and CAN/ULC-S115 Nominal Joint Width -- 3/4 In. 2B 2C 2A 1 3 1. Floor Assembly -- Min 4-1/2 in. thick reinforced lightweight or normal weight (100-150 pcf) structural concrete. Floor may also be constructed of any 6 in. thick UL Classified hollow-core Precast Concrete Units*. See Precast Concrete Units category in the Fire Resistance Directory for names of manufactures. 2. Wall Assembly -- The 1 or 2 h fire-rated gypsum board/steel stud wall assembly shall be constructed of the materials and in the manner specified in the individual U400 or V400 Series Wall or Partition Design in the UL Fire Resistance Directory. In addition, the wall may incorporate a head-of-wall joint system as specified in the HW Series Joint Systems in the UL Fire Resistance Directory. The wall shall include the following construction features: A. Steel Floor Runners -- Floor runners of wall assembly shall consist of min No. 25 gauge galv steel channels sized to accommodate steel studs (Item 2B). Floor runners to be provided with 1-1/4 in. flanges. Runners secured with steel fasteners spaced 12 in. OC. B. Studs -- Steel studs to be min 3-1/2 in. wide. Studs cut 1/2 to 3/4 in. less in length than assembly height with bottom nesting in, resting on and fastened to floor runner with sheet metal screws. Stud spacing not to exceed 24 in. OC. C. Gypsum Board* -- Gypsum board installed to a min total thickness of 5/8 or 1-1/4 in. on each side of wall for a 1 or 2 hr rated wall, respectively. Wall to be constructed as specified in the individual U400 or V400 Series Design in the UL Fire Resistance Directory, except that a max 3/4 in. gap shall be maintained between the bottom of gypsum board and top of concrete floor. The hourly fire rating of the joint system is equal to the hourly fire rating of the wall. 3. Fill, Void or Cavity Material* Sealant -- Max separation between top of floor and bottom of wall is 3/4 in. Min 5/8 in. thickness of fill material installed on each side of the wall between the bottom of the gypsum board and the top of the concrete floor, flush with each surface of the wall. . HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- CP601S Elastomeric Firestop Sealant, CP606 Flexible Firestop Sealant or FS-ONE Sealant *Bearing the UL Classification Mark Reproduced by HILTI, Inc. Courtesy of Swedish Edmonds ACC Underwriters Laboratories, Inc. Expert Drywall, Inc. June 12, 2003 078446 Submittal Page 46 1.2.D BWS 0023 S S I A F L I System No. BW-S-0023 C E D Assembly Ratings — 1 and 2 Hr (See Item 2) CUS Joint Width — 1 in. Max Classified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 2B 2C 2D 2A 3 1 1. Floor Assembly — Min 2-1/2 in. (64 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) structural concrete. 2. Wall Assembly — The 1 or 2 hr fire rated gypsum board/steel stud shaft wall assembly shall be constructed of the materials and in the manner specified in the individual U400 or V400 Series Wall and Partition Design in the UL Fire Resistance Directory. In addition, the wall may incorporate a head-of-wall joint system constructed as specified in the HW Series Joint Systems in the UL Fire Resistance Directory. The wall shall include the following construction features: A. Floor and Ceiling Runners — J-shaped runner, 2-1/2 in. (64 mm) wide with unequal legs of min 1-1/4 in. (32 mm) and 2 in. (51 mm), fabricated from min 24 MSG galv steel. Runners positioned with short leg toward finished side of wall. Runners attached to structural supports with steel fasteners located not greater than 2 in. (51 mm) from ends and not greater than 24 in. (610 mm) OC. B. Steel Studs — C-H-shaped studs, 2-1/2 in. (64 mm) wide by 1-1/2 in. (38 mm) deep, fabricated from min 25 MSG galv steel, cut to lengths 3/8 to 1/2 in. (10 to 13 mm) less than floor to ceiling height and spaced 24 in. (610 mm) OC. Studs nest in floor runner at bottom and J runner or slotted ceiling track at top. After installation of gypsum board liner panels (Item 2C), studs secured to flange of floor runner on finished side of wall only with No. 6 by 1/2 in. (13 mm) long self-drilling, self-tapping steel screws. Studs secured to flange of slotted ceiling track on finished side of wall only with No. 8 by 1/2 in. (13 mm) long self-drilling, self-tapping wafer head steel screws at slot midheight. C. Gypsum Board* — 1 in. (25 mm) thick by 24 in. (610 mm) wide gypsum board liner panels as specified in the individual U400 or V400-Series design. Panels cut 1 in. (25 mm) less in length than floor to ceiling height. Vertical edges inserted in "H"-shaped section of "C-H" studs. At the ends of the assembly, the free edge of the end panels are attached to the long leg of vertical J-runners (Item 2A) with 1-5/8 in. (41 mm) long Type S steel screws spaced max 12 in. (305 mm) OC. D. Gypsum Board* — Gypsum board sheets, 1/2 or 5/8 in. (13 or 16 mm) thick, applied vertically or horizontally in two layers on finished side of wall as specified in the individual U400 or V400-Series design. A max 1 in. (25 mm) gap shall be maintained between the bottom of the gypsum board and the top surface of the concrete floor. The screws attaching the gypsum board layers to the C-H studs shall be located 1 in. (25 mm) above the top of the J-runner or slotted ceiling track. No gypsum board attachment screws are to penetrate the ceiling J-runner and slotted ceiling track. The hourly fire rating of the joint system is equal to the hourly fire rating of the wall. 3. Fill, Void or Cavity Material* Sealant — Max separation between top of floor and bottom of gypsum board on the finish side is 1in. The depth of sealant to be installed to fill the linear gap between the bottom of the gypsum board sheets (Item 2D) and the top of the concrete floor shall be equal to the overall thickness of the gypsum board sheets, flush with the finished side of the wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 606 *Bearing the UL Classification Mark Reproduced by HILTI, Inc. Courtesy of Swedish Edmonds ACC Underwriters Laboratories, Inc. Expert Drywall, Inc. May 17, 2010 078446 Submittal Page 47 Swedish Edmonds ACC Expert Drywall, Inc. 078446 Submittal Page 48