0961_001.pdfApril 26, 2019
REMODEL/FIRE DAMAGED HOUSE
City of Edmonds, WA
Building Permit Application # BLD20190224
22130 92"d AVE W
Edmonds, WA
Subject: PLANNING COMMENTS REVIEW#1
Dear, Eric Carter
SOWMeW
We are writing this letter, so that we may in greater depth explain our response to your requests. We will
attempt to explain how and where you question, we addressed.
The changes on the plan were clouded for greater clarity.
Building plans review
A05:
1. The proposed door at the bottom of the stairs from the master bedroom to the main level
is not permitted per IRC R311.7.6. The landing at the bottom of the stairs shall be at
least the width perpendicular to the direction of the flight served. Please remove the door
from the bottom of the stairs, if a door is still desired, locating the door at the top of the
stairs to the master bedroom would be acceptable if designed in accordance with the
exception to Section R311.7.6. Please clarify and change on the plans.
Response: The sheet A05 has ben revised. The door has been moved at the top of the stairs.
2. It appears that portions of wall line 2 the proposed perforated shear wall exceed the
aspect ratios of table 4.3.4 of the SPDWS, 2015 edition for unblocked walls. Please
clarify.
Response: Please see Wendell Reed responded letter.
3. It appears that the proposed openings of wall line 4 do not comply with section 4.3.5.3,
item 6 of the 2015 SPDWS. Please clarify.
Response: The lot structural coverage area has been revised and corrected.
Response: Please see Wendell Reed responded letter
Structural Calculations;
4. Upon review of the provided lateral calculations, it appears that wall line 1 requires hold
downs to prevent over turning. Please clarify.
Response: Please see Wendell Reed responded letter
Tatyana Shadyrya
Archstudio"Y.Shadyrya"
205 240-7329
yshadyrya@yahoo.com