1 2.pdfo� EDS City of Edmonds 0 PLAN REVIEW COMMENTS BUILDING DIVISION Esc. ts9° (425) 771-0220 DATE: February 22, 2006 TO: Jose Kennard Fax (425)744-9799 FROM: Jenny Readwin, Plans Examiner RE: Plan Check # 06-025 Project: Kennard Porch Enclosures Project Address: 1031 C Ave S. During re -review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please note minimal information was submitted and it is likely that there will be additional corrections after the items below are addressed. 1) Still need -no response given. Site plan says proposed covered deck. Is this included in this scope of work? If so, provide deck construction plans and details for review. 2) Still need -no response given. Clearly note on the site plan the location of the additions as part of this permit application. 3) Still need -no response given. Clarify proposed uses of space. Plans say office and hobby/craft room and permit application says for dinning room and exercise room. Coordinate. 4) Still need. Expand floor plan to show all rooms adjoining the additions (both locations) including any and all doorways, windows, closets, hallways etc. 5) Still need. For new hobby/craft room enclosure provide complete floor framing and foundation plans to show how all loads are being carried to bearing. Also, since this space is being converted to habitable space it must meet current code (i.e. continuous foundation, floor insulation, etc.). 6) Option deleted-ok but still need size ofposts and how all loads are being carried to bearing. Provide engineered detail for option to sister new 3 118" x 12 GLB ridge to existing 6x12 since the Glulam is and engineered wood product. Also, specify size of posts and show how all loads are being carried to bearing. 7) Still need calculations -none provided. Enclosed hobby/craft room as well as the proposed office area does not meet the minimum wall bracing requirements of the IRC. Provide lateral calculations stamped and signed by a Washington State Licensed Professional Engineer or revise plans to meet conventional construction. 8) ok 9) Still need. Specify where cross section on sheet 3 applies. 10) Note says new 18" x 12" continuous footing typical where applicable. Provide foundation detail including required rebar. Provide a foundation plan for new office area. A continuous foundation is required at this location unless calculations are provided stamped and signed by a Washington State Licensed Professional Engineer. .Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the above items to.a Permit Coordinator.