Loading...
1.10.18 Eng. Correction Notice BLD20161685.pdfCITY OF EDMONDS CORRECTION NOTICE ENGINEERING DIVISION (425) 771-0220 City Website: www.edmondswa.gov DATE: January 10, 2018 PERMIT NUMBER: BLD20161685 OWNER: Enfort Homes LLC SITE CONTACT: Brett ADDRESS: 7508 2101h ST SW. TYPE OF INSPECTION: Stormwater Detention System & Complex Entrance/Approach Slope ❑ WORK DESCRIBED BELOW HAS BEEN INSPECTED AND APPROVED ❑ APPROVED PLANS AND PERMIT JOB CARD MUST BE AVAILABLE TO INSPECTOR ON SITE ® CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED AND/OR THE NEXT PHASE OF WORK IS STARTED. ❑ RECALL FOR INSPECTION ❑ REINSPECTION FEE MUST BE PAID PRIOR TO NEXT INSPECTION REQUEST. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY CITY INSPECTOR A revision to the onsite stormwater management system will need to be submitted to the city. Please address the following. 1. The recently installed type II manhole (control structure) has created a slope that exceeds the city's required maximum 14% slope at the approach of the complex. The slope will need to be corrected. Please provide an updated site plan and profile that shows the new proposed slope. 2. Provide a updated detail of the control structure accounting for all elevations, material thicknesses (i.e., iron, minimum required 2" concrete riser, manhole lid thickness) as well as catch, control tee height (in relation to the detention system) and the required 6" clearance. 3. Updated profiles of the complete stormwater management system will need to be submitted. 4. If shifted an updated site plan showing the new location of the storm water management system will need to be submitted. 5. Please show that the minimum coverages over the detention and manholes structure can be achieved. For inspection scheduling call 425-771-0220 x1326.