100021799 Permit App (2).pdf!. �� Of EDtjo+
4 f v6,j,
ROW PERMIT NO.: ENG
ISSUE DATE:
- - - R 11 G K 1 'll'.-Oli-i'..WA)( �; o IN S�I[ RUCTION
11vc. l.3yo PERMITAPPLICATION
PROJECT NAME: CONTACT:
EDMONDS POST OFFICE PHASE II DEBRA LAWSON
CONTRACTOR: SNOHOMISH COUNTY PUD
Mailing Address: PO BOX 1107, EVERETT 98206
State License #:
City Business License #:
Phone #: 425-783-4414
Fax #:
Email N' DEVORAHLAWSON@GMAIL.COM
❑ Liability Insurance ❑ Bonded
ADDRESS OR INTERSECTION Or CONSTRUCTION: ?,01 "%Vj
or -
ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT:
IX Commercial ❑ Subdivision ❑ City Project ❑ Traffic Control (Only)
[A Multi -Family ❑ Single Family ❑ Other
4 EUC (PUD, VERIZON, PSE,
COMCAST, OVWSD):
Is this permit part of a blanket permit? ❑ Yes ❑ No
ANY ASSOCIATED PERMITS? BLD# ENG#
DESCRIPTION OF PROPOSED WORK (Be Specific) : MAINTENANCE TO EXISTING PADMOUNT TRANSFORMER
AND INSTALL OF NEW PADMOUNT TRANSFORMER FOR CUSTOMER. WORK WILL BE DONE WITH A CRANE SET-UP IN EXISTING
LOADING DOCK. BUILDING HAS GENERATOR SO NO OUTAGE EXPECTED. JOB IS ESTIMATED TO TAKE APPROXIMATELY 16 HOURS.
WORK WILL BEING AT APPROX. 9AM ON A NORMAL WORK DAY (M-F) AND WORKED UNTIL COMPLETE.
WAS STREET OVERLAYED WITHIN THE LAST FIVE 5 YEARS? YES ❑ NO ❑ Year:
PAVEMENT CUT: ❑ Yes ® No If yes, indicate size of cut: x
CONCRETE CUT: ❑ Yes ®. No If yes, indicate size of cut: _ x
RIGHT-OF-WAY AREA TOTAL
CLOSURE
Sidewalk 48 Hrs + LF X LF `4
Alley 72 His + LF X LF SF
Parking 72 Hrs + LF X LF SI'
DURATION
(NUMBER OF MONTHS)
APPLICANT TO READ AND SIGN
*Traffic control and public safety shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification
verifying completion of the required training in their possession.
*Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be
patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS.
Indemnity: The Applicant has signed an application which states he/she hold the City of
Edmonds harmless from injuries, damages or claims of any kind or description
whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or
any of its departments or employees, including defense costs and attorney fees by reason
of granting this permit.
I have read the above statements and understand the permit requirements and acknowledge that I must
follow all requireme is in order f r the permit to be valid.
SIGNATURE tom. C DATE - -
Contractor or Agent
NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE
LANE CLOSURE ON A TWO-LANE ROAD
PUD WO# 100021799
(TWO FLAGGER OPERATION)
�*cu_
W20-1
ONE LANE
W 2 0 - 4 ROAD
AHEAD
m
W20-7A ��
a
Z.�
53
00
N rn
W
Ld
F-
()
0
Z
N
Q
G20-2A END
ROAD WORK
(OPTIONAL)
Y
i ROADN►ORK G2 0 - 2 A
a (OPTIONAL)
O
O o
O o
00
O
1 0:01
W
U.
Li
m
z
W 5=201
Sk o0
7~ Loo MAIN ST
Q
s tT
W20-7A
m
SPEED
LIMIT
SIGN
SPACING
A, B,C (FT)
BUFFER
(FT)
25
200
55
30
200
85
35
350
120
40
350
170
45
500
220
50
500
280
55
500
335
ONE LANE
AL ROAD W20-4
AHEAD
U
ROAD
AL WORK W20-1
AHEAD
LAYOUT LEGEND:
19�
PAD MOUNTED TRANSFORMER
V
SUBMERSIBLE TRANSFORMER
Go
ABOVE GROUND J-DOX
D�Jy
SUBMERSIBLE J•BOX
W
SECONDARY VAULT
O
PULLING VAULT
Q
SWITCH CABINET
SMALL SECONDARY PEDESTAL
Q
LARGE SECONDARY PEDESTAL
PRIMARY UNDERGROUND CABLE
8350 SECONDARY UNDERGROUND CABLE
4/0 SECONDARY UNDERGROUND CABLE
VO SECONDARY UNDERGROUND CABLE
STREET LIGHT CABLE
SERVICE CONDUIT
0
POLE AND OVERHEAD LINE
PROPERTY LINE
RIGHT-OF-WAY LINE
— U
EXISTING UNDERGROUND CABLE
�
'EXISTING DUCT
FUTURE DUCT
S
OSANITARY SEWER/MANHOLE
D---OSTORM
DRAIN/CATCH BASIN
W
,:WATER MAIN/METER
Y
FIRE HYDRANT
•
STREET LIGHT
*
UNDERGROUND LOCATOR MARKER
SCHEMATIC LEGEND:
• 10 TRANSFORMER
EEEEBI 3 A TRANSFORMER
0 SUBMERSIBLE TRANSFORMER
0 200 AMP J-BOX
■ 600 AMP J-BOX
FUSE
PRIMARY UNDERGROUND CABLE
0" EXISTING OVERHEAD
--1 t--DISCONNECT SWITCH,NORMALLY OPEN
—ice— OISCOWC7 SWITCH. NORMALLY CLOSED
�I STANDOFF BRACKET
_FEEDER LINE
8 PULL THRU BOX
9 FEED THNU GUSHING ON TRANSFORMER
0-FAULT INDICATOR
—u-- ADOITIONAL UGNO TAPPED AT T/0 POLE
TRANSFORMER 12470-2081-201,
BY PUD OR PUD'S 0041RACTOR
300 KVA
UTC
SER
MAKE
VAUL T BY CUSTOMER
9.4- X 54- X 4-CONCRETE VAULT
5-4. X 4:CONCRETE COVER WITH 36- X 36- DIAMOND PLATE LIO
WX WCONCRETE COVER WITH 507 X 18- ACCESS HOLE
CONSTRUCTION NOTES
A-47777
TURN XFMR 180°FOR FUTURE TRANSPORT
XFMR AREA WILL BE ENCLOSED WHEN PEDESTRIAN BRIDGE IS INSTALLED BETWEEN BLDGS
-RAIV XFMR
-SWAP XFMR LIDS
-REINSTALL XFMR SO BACK (HEAVY END) WILL FACE LOADING DOCK
AO AT NEW VAULT
-INSTL 300KVA 12470/120/208V PADMOUNT
-PULL 50'OF (3)1/0 UG PRI CABLE FROM A-47777
-INSTL (6) ELBOWS T1105
-ENERGIZE XFMR
CABLE ALL FooTAGES *PROXIMATE
8Y PUD OR PUO S CONTRACTOR
W OF (3) " AL 15KV CNCTRC NEUT JCKTO PRIIN 4' PVC
MAKE PO REEL
FT MARK TO
DUCT
pA 0 OF (2) A- PVC BY CUSTOMER
SWgY:SM COW IY 1 A\/\ �� M• CA
�o vvv
LOCATION MMM fl.[ AREA LYNNWOOD
VAULT Ito_A-47777 SEV+S23 727 RO DATE 03-22.18 ORDER 1000m
REASON FOR WORK PROVIDE 30 PRIMARY ENGINEER_ D. LAWSON OPERATION 0050
MYRGROUND SERVICE FOR DRAFTER UGhO NO_SM
LIC APPROVEO SCALE N79
6
DATE MORR COVPLETEO FOREVA4 DATE
SUBSTATIOi_MPL INSPECTOR
CIRCUIT N0 343 PHASE _t13 GATE
—•—-----•-_-- _ FEES REO'D .YES ONO
L
❑ RESIDENTIAL
0 COWERCIAL
LED•
0, .i
PRIMARY UNDERGROUND
O RESIDENTIAL
PERMITS
(DATE GRANTED)
O COVVERCIAL
0TREE TRIV
BASIC FEE i_
IEU+
OSTATE
0 f_�•. t
0 COUNTY
■CITY
SECONDARY UIDERCROUND
BASIC FEE,
0
o %_A•. %
EASEMENTS
E•
■ REOUIREO
ONOT REOUIREC
REQUEST NO.
DATE APPROVED
FOREIGN CONTACTS
❑ .Ph+
❑ .q:Ni TRENCH
FRONTIER t CATV
0 JOI.NT BORE FRONTIER 6 CATV
❑ PRIVARY
❑ SECONDARY
_FT O t_.I
MISCELLANEOUS FEES
VAULT ,
PERVIT %
t
f
TOTAL DUE%
DATE PAIO_
VICINITY MAP
TAGS
VAULT,
CABLE,
10
TAKE OFF
THEE TRi4 0 PUD LOCATOR
BA4XHOE ■ CRANE
OE CALL DATE
9
R I ifilofilulolft I