Loading...
10-0129. Ali addition pdf.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: 3/9/10 TO: Kristin Hanson 652 Alder Street Edmonds, WA 98020 RE: Plan Check: BLD20100129 Project: Ali Addition and Remodel Project Address: 709 Driftwood Pl During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, and submit revised plans/documents to a Permit Coordinator. Provide a full lateral and gravity engineering calculations and details. Include possible 1. surcharges to existing basement foundation walls. Address screws in lieu of nails at sub-floor. Identify hurricane clips at rafters for uplift. 2. Specify lumber species and grades for all structural lumber. 3. Section A/3: 4. Accurately depict the base of the footings for both the existing basement wall, and the a. proposed footing. Ledger connection and flashing detail b. Required rotation blocking c. Provide an existing kitchen floor plan showing the sink, stove and refrigerator layout. 5. Provide a proposed kitchen floor plan showing the sink, stove and refrigerator layout. 6. Roof Plan/3 7. Overframing sleeper detail a. 3-1/8”x9” (or 4x10) connections to existing and proposed walls: let-in or hanger b. requirements, posts at walls Railing/4: Provide connection of rim joist to joist connection requirements for raining to meet 8. the minimum 200 lb load at top of rail. Engineer may need to address this. General notes: 1-The currently adopted NEC is the 2008 version. 9. Section B/4 depicts the rafter sitting on top of, instead of along side of ceiling joist. Provide 10. connection detail including hurricane clip for uplift. Pat Lawler patrick.lawler@ci.edmonds.wa.us Plans Examiner 425 771 0220 x1703