10-0845 Plan Review Comments.pdf CE ITY OF DMONDS th • 1215 AN•E,WA98020 VENUEORTHDMONDS P: 425.771.0220 • F: 425.771.0221 • W:www.ci.edmonds.wa.us HONEAXEB DSD: P•E•B EVELOPMENT ERVICES EPARTMENTLANNINGNGINEERING UILDING November 23, 2010 Mr. Kevin Weed Email: Kevin@resortappraisal.com RE: PLAN REVIEW COMMENTS FOR PLAN CHECK # 2010-0845 WEED BUILDING PERMIT APPLICATION AT 24227 FIRDALE AVENUE Dear Mr. Weed: I have reviewed the above building permit application for the Planning Division, and it was found that the following information, corrections, or clarifications will need to be addressed before review can continue: Site Plan: Please make the following corrections to your site plan: 1. a.Provide all of the minimum required information as listed in the attached plot plan checklist (#B57). b.Indicate the dimensions of the property and provide the lot area. c.Indicate the location of the proposed dining room addition as shown on the building plans. d.Indicate the locations of the proposed supporting posts for the carport. Setbacks 2.: The minimum required setbacks for the RS-8 zone are measured from the property lines as follows: Street = 25’, Sides = 7.5’, Rear = 15’. The proposed extension off of the dining room will need to be shown to comply with the minimum required 7.5-foot side setback from the southeastern property line. Thus, please indicate the shortest distance from this addition to the property line on your site plan. Based on the dimensions provided on your site plan, the carport and third bedroom off of the kitchen are located within the minimum required 7.5-foot side setback. Edmonds Community Development Code (ECDC) 17.40.020 defines a nonconforming building as “one which once met bulk zoning standards and the site development standards applicable to its construction, but which no longer conforms to such standards due to the enactment or amendment of the zoning ordinance of the City of Edmonds or the application of such ordinance in the case of a structure annexed to the city.” Structures built without the proper permit required at the time of construction are not considered nonconforming. If a structure is found to be nonconforming, it is subject to the nonconforming regulations of ECDC 17.40, which include the allowance for maintenance of the structure so long as it does not expand the extent of the nonconformity. Staff is unable to determine whether the third bedroom off of the kitchen was legally constructed or if this portion of the residence was constructed without the required permits. Please submit documentation of this portion of the residence being constructed to the standards and with the permits required at that time. Lot Coverage 3.: Lot coverage is defined as the total ground coverage of all buildings or structures on a site measured from the outside of external walls or supporting members or from a point 30 inches in from the outside edge of the eaves, whichever covers the greatest area. The maximum allowed lot coverage for the RS-8 zone is 35 percent of the net lot area. Please provide the proposed lot coverage in square feet and as a percentage of the net lot area on the site plan. Height 4.: Since you are proposing to expand the existing residence, please provide height calculations on your site plan, and indicate the average grade, proposed height, and maximum allowed height on an elevation view of the proposed expansion. Height calculation information is provided in the attached handout (#B41). All submittals should be made to a Development Services Permit Coordinator, Monday through Friday, between 8:00 am and 4:30 pm. If you have any questions, feel free to contact me at (425) 771-0220, ext. 1224. Sincerely, Development Services Department - Planning Division Jen Machuga Planner