Loading...
1080_001.pdf")C. 194 February 9, 2017 Lee Johnson CITY OF EDMONDS 1215 1h Avenue North, Edmonds WA 98020 Phone: 425.771.0220 • Fax: 425.771.0221 • Web: wwwww.ediriond uwa.gov DEVELOPMENT SERVICES DEPARTMENT • PLANNING DIVISION 2410 W Park Dr. E Seattle, WA 98112 (425)324-2600 hieejohnsonl@gmail.com SUBJECT: REQUEST FOR ADDITIONAL INFORMATION FOR PROPOSED SHORT PLAT LOCATED AT 8632 184th St. S.W., FILE NO. PLN20160055 Dear Mr. Johnson: During staff's continued review of your application it was determined that additional information/clarification is necessary. Please provide responses to the following items at your earliest convenience so that staff's review of the proposal can continue: 1, Please respond to the comments from JoAnne Zulauf, Engineering Technician, provided in the attached memorandum dated February 7, 2017. If you have any questions on Ms. Zulauf s comments, you may contact her at (425) 771-0220 oro nne.Zultau fCa) 2. In response to item #7 of Engineering's memo, please adjust lot area accordingly, 3. Please respond to the comments from Kevin Zweber, Deputy Chief — Fire Marshall, provided in the attached memorandum dated December 8, 2016. Please submit the above information to the Planning Division as soon as possible so that staff may continue processing your application. Please keep in mind that a complete response to this information request must be received within 90 days or the application will lapse for lack of information (ECDC 20.02.003.D). Thus, your application will expire if the requested information is not received by May 10, 2017. If you have any questions, please do not hesitate to contact me via phone at (425) 771-0220 or via email at Brad,Shiplpy: c clral������1*� ley• Sincerely, Development Services Department - Planning Division Brad Shipley Associate Planner Enclosure: Memorandum from JoAnne Zulauf dated February 7, 2017 Memorandum from Kevin Zweber dated December 8, 2016 Cc: File No. PLN20160055 Mr. H. Lee Johnson (via email: hleejohnsonl@gmail.com) Mr. Andrew Reaves (via email: areaves@sdaengineers.com) Mr. Michael Gallavan (via email: mfgallavan@comcast.net) Page 2 of 2 Date: To: From: Subject: LVA f February 7, 2017 Brad Shipley, Associate Planner JoAnne Zulauf, Engineering Technician PLN20160055, Gallavan 3 lot short plat 8632 184" St SW The comments provided below are based upon review of the preliminary civil plans & documents for the subject short plat. Additional information is requested from the applicant at this time in order to continue review of the application and provide preliminary approval of the short plat. Please ask the applicant to provide a written response to each of the outstanding comments below and revise and resubmit plans accordingly. Edmonds Community Development Code (ECDC), Handouts, Standard Details and other pertinent information is available on the City website: www.edmondswa.gov. Please also note, after receiving preliminary short plat approval from the Planning Division, the applicant will be required to submit civil engineering plans to the City for review and approval. GENERAL 1. The address 8632 184th has been designated for this property. Please revise all plans, reports, etc with this address. 2. Clearly indicate proposed points of access for each lot. 3. In accordance with Edmonds Community Development Code (ECDC) Chapter 18.90, sidewalks are required as a condition of short plat approval. Sidewalks shall be 5 ft in width with a ramped driveway approach (see Edmonds Standard Details (EDS) E2.13, E2.8, E E2.26. 4. Sidewalk location shall be revised to the north allowing catch basin #2 to fall into the gutter line. 5. CB #1 shall be moved north into the sidewalk gutter line. Stormwater main will no longer jog to the south as shown on the current proposal. 6. Access width requirements — current design meets code requirements. (Note: the requirement for access to 3 to 4 lots is a 20' easement width and 16' width of paving with 18" curb or asphalt edge to direct stormwater flow. See ESD E2.1.1). 7. A turnaround is required by the engineering division. The turnaround shall be designed to meet the requirements of ESD E2.6.2. No additional turnaround width is required for emergency access per Fire Comments. City of Edmonds UTILITIES 8. Show the location of sanitary sewer systems, water mains and water service lines to a stub out for each lot. Provide approximate invert elevations for side sewer at lot property line, subdivision property line, and new connection to main to show feasibility. Call out length and size of all pipe to verify slopes. See handouts on our website for additional information. STORMWATER 9. Please show a simple outline of driveway/house on each lot meeting the impervious surface total used to design the stormwater bmp for said lot. This does not need to be the final lot design, the purpose is to review access and that a configuration of impervious surface and the required bmp is attainable within code requirements. 10. Please revise the location of CB # 3 or add an additional CB to provide collection of all of the tract runoff. The current plan shows CB #3 with a rim invert of 329.34, the contour at the street for the tract is 328. It appears that there are many possible points of connection for this CB that would better meet this requirement. 11. The WWHM modeling for the Tract uses Everett gage, Puget East 36 is the appropriate gage for this area. 12. The additional impervious surface in the right of way shall be captured and directed to the subdivision stormwater bmp. For this phase, including the area in the stormwater bmp design sizing will suffice. The design path to accomplish collection will be addressed during the civil review process. 13. The drainage design shown on the civil set is not the same as the design modeled and shown in the Preliminary Drainage Report. Please revise as needed for consistency. Thank you. yy ! CITY OF EDMONDS DEPARTMENT OF FIRE PREVENTION 12/8/2016 PLANNING PERMIT REVIEW NOTES FOR 8632 184th Street SW, Edmonds PLN20160055 Comments and Conditions 1. Require fire access road including fire lane markings — 20' all weather surface, starting at the public road to the beginning of the furthest southern parcels driveway, no turn -around required. 2. All structures are required to be provided with a NFPA 13D residential fire sprinkler system regardless of the square footage of the fire area. Kevin Zw r Deputy-hif - Fire Marshal City of Edmonds, Department of Fire Prevention 425-771-0213 Office 12425 Meridian Avenue S / Everett WA 98208 / 425-551-1200 www.firedistrictl.org