Loading...
11-0157 McManus deck.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: 3/11/2011 TO: Casey McManus nd 8717 182 Pl Edmonds, WA 98026 RE: Plan Check: BLD20110157 Project: Deck replacement Project Address: same During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, and submit revised plans/documents to a Permit Coordinator. 1.Structural notes on sheet 8 indicate an Engineer of Record, Thompson Engineering. If so, the EOR, by state law, is required to stamp and sign the plans and provide the calculations. If not, then remove the name and reference from the plans. 2.Indicate the slope of deck. 3.Indicate the type of membrane or waterproofing materials proposed. 4.The beams, as drawn, appear to be exposed to the weather, and would thus be required to be pressure preservative treated. Either provide weather proofing detail, or PT wood. PT dimensional lumber is HF#2, see #7. If PT-DFL beams are to be used be advised they may be special order items. 5.The beams are over spanned according to the standard deck detail 4/4. Provide beam calculations. 6.A minimum 3’ landing is required at the base of the stairs. Indicate the material proposed for the landings. 7.The stairs, as drawn, do not appear to be constructed like standard detail 6/3 on sheet 10. Indicate the stringer framing and, if 2x12’s or notched 4x12’s, provide a mid span beam below the long spanned stair run. Pat Lawler, CBO patrick.lawler@ci.edmonds.wa.us Plans Examiner/Building Inspector 425 771 0220 x1703