114 Caspers - pump.pdfMcCoren eli, Jeanie From: WC.oriiiell, Jearire S enC'rijesday, Decernber 18, 2012 1:45 PM I Ci. "1 11 rbladdom/ 1 @co rrr cast. ri et J FVV: E - 'kIGRSt 2012031 9 - oraiwater Fkirr)p Syste.ae ni 114 (.,srJe�,,1 1,` Attachrrients: Barnes FUrrip Atlachrnerit; Purrq�) Ce�spers Street l3lease firid attacIlred City apt)roval of tl�re proposed Zoeller purrup U) be Use,(] at your iesiderice - 11.4 Caspers Sl:reet. I'llaril( YOU arid Happy Holklays, Jea ri ie From SliLister, Jerry Sent: Tijesday, December 18, 20,1.2 9:1.6 AM To" McConnell, Jeanie Stotiject: ENGR201120319 .. Storamater PUMP Systern 111, Caspers Hi, Yesterday I got a call from Richard Blacklow the new owner of 114 Caspers. He told me they have been having problem with the pump systern recently installed by Joe Schniaus and his contractor-. The systema was designed by Donna Breske, P.11". and approved by the City in August 2012. According to Richard, the PUMP was not tams rflng on properly, rnost likely a problem with the float switch and the alarm kept going o ff., Mr. Schmaus and his contractor were replacing the existing pump with a Zoeller model 1 53. Richard wanted to know if this was OK with. the City. I've looked at the performance, curve of the Zoeller- M53 compared to the originally specified pump (Barnes model SU 33), and they are very similar (Ms Breske had sent information on this issue last Friday 11/14 --see attached). The Zoeller pump will provide a slightly lower flow rate which will be lower than the allowable discharge to the City stormwater system, I called Richard back today and told him the Zoeller pump was OK from the City's point of view.I also told him it was not the City's responsibility to ensure the pump system functions properly. It is the responsibility of the owner and/or Mr. Schmaus and his contractor. Richard would like an e-mail from you saying the new pump is approved. Sincerely, Jerry Shuster, P.E. Storrawater Engineering Program Manager City of Edmonds 121 Sth Ave N. Edmonds, WA 98020 Desk Phone: 425-771--0220)c1.323 it 425-672-5750 Lemcv eShu_st _er@kd!11gL11d_S_XTa-gP.Y Shuster, Jerry Tc: McConnell, Jeanie Subject: ENGR20120319 - Stormwater Pump System 114 Caspers Attachments. Barnes Pump Attachment; Pump Caspers Street Hi, Yesterday I got a call from Richard Blacklow the new owner of 114 Caspers. He told me they have been having problem with the pump system recently installed by Joe Schmaus and his contractor. The system was designed by Donna Breske, P.E. and approved by the City in August 2012. According to Richard, the pump was not turning on properly, most likely a problem with the float switch and the alarm kept going off Mr. Schmaus and his contractor were replacing the existing pump with a Zoeller model M53. Richard wanted to know if this was OK with the City. I've looked at the performance curve of the Zoeller M53 compared to the originally specified pump (Barnes model SU 33), and they are very similar (Ms Breske had sent information on this issue last Friday 11/14 - see attached). The Zoeller pump will provide a slightly lower flow rate which will be lower- than the allowable discharge to the City stormwater system. I called Richard back today and told him the Zoeller pump was OK from the City's point of view. I also told him it was not the City's responsibility to ensure the pump system functions properly. It is the responsibly of the owner and /or Mr. Schmaus and his contractor. Richard would like an e -,mail from you saying the new pump is approved. You can probably jus forward this. Sincerely, Jerry Shuster, P.E. Stormwater Engineering Program Manager City of Edmonds 121 Sth Ave N. Edmonds, WA 98020 Desk Phone: 425-771-0220 x1323 Fax: 425-672-5750 Jerry.Shustergedmondswa.gov Shuster, Jerry From: donnabreske@comcast.net Sent: Sunday, December 16, 2012 6:52 PM To: Shuster, Jerry Subject: Pump Caspers Street Jerry, I have been told the City Engineering Department has visited 114 Caspers Street to look at the pump and that the alarm has gone off a couple of times. It is a Barnes 113 hp pump that has been installed in the pump basin. Because the float is housed in an shroud it is important that the pump remains level in order for the float to work correctly, (see attached Product Sheet). Please have city engineers confirm the pump is placed in a level position. Please feel free to contact me with any comments or questions. Sincerely, Donna L. Breske, P.E. Phone: 425-334-9980 Shuster, Jerry From: donnabreske@comcast.net Sent: Sunday, December 16, 2012 6:55 PM To: Shuster, Jerry Subject: Barnes Pump Attachment Attachments: Barnes 0.3 hp pump, Product Sheets.pdf; Barnes 0.3 hp pump, Product Sheets.pdf Jerry, The Barnes pump attachment. -Donna Zodler Puirip ('201"l7p"Illy U) I PUPH"I PFRFOR�VIANICE" CL)RVE" "'5157/59 MODELS 13, 201 GALLONS , LITERS 0 80 FLOW PER MINUTE in '160 C- C, r- I" .. Purnp Perforinance Clurve Mod(�Is DDI �"))' ID 9 .. ... . . .. o� 72cnnm .�.ll Page I of I fl 2/17/2,012 If yoti want a purnpi"hat las "I's, buy one with a BETTER switch Availdble Models:� -AZ41 E n 0 SIJ33 - 1/3 � �o, I I I �1� � I d �=. E:j Float is housed in a shroud -to guard against obs-truction and wedging. Magnets activate swii:ch as float rises and falls. Tes,ted,to over I million cycles. 114 CASPERS ST EDMONDS, WA CRANE PUMPS & SYSTEMS ® 020t0 Crane Pumps E, Systems, Inc. R Crane Co. Com 8!] A Y A Crane Co. Company Printed in U.S.A. cw BPPSU (8110) C us Crane Pumps &c Systems Crane Pumps &a Systems Canada 420 Third Street 83 West Drive Piqua, Ohio 45356 Brampton, Ont. Canada L6T2J6 (937) 778-8947 (905) 457-6223 Fax (800) 328-7573 Fax (905) 457-2650 www.cranepumps.com