Loading...
12_Ave_N-1316_Cutts_ADD_BLD20080053_2.pdf City of Edmonds TH 121 5 AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Plan Review Comments Permit:Date: #BLD200800535/22/08 th Project Name/Address: Cutts – ADD, 1316-12 Ave N, Edmonds, WA 98020 Contact Person/Address/Fax: __________________________________________________________________________________________ Kearsley Homes, Inc – 6631 Norma Beach Rd, Edmonds, WA 98026 – r@kearsleyhomes.com ______________________________________________________________________________________ Reviewer: Division: Jennifer Collins Engineering During review of the subject submittal it was found that the following information, corrections, or clarifications will need to be addressed: st 1 Review – 1/30/08 nd 2 Review – 5/22/08 5/22/08 – Comment was addressed by submittal of ‘Detention System Analysis’ – Currently 1) being reviewed by City of Edmonds Storm Water Engineer, Don Fiene – Any comments will follow. Previous Comment: Please submit the drainage report from the original construction of the three homes, 1312, 1314, and 1316 12th Ave N. If you do not have the report the engineer that completed the Development plan was Lovell-Sauerland and Associates. They might have the drainage report. If the original engineering calculations are unavailable, then the capacity of the system will have to be recalculated by a licensed engineer. 5/22/08 – Comment was addressed on the large scale drawing, but needs to be added to the 2) reduced site plan Previous Comment: On the site plan please show the impervious surface designed for the detention system as well as any additions completed after the existing system was installed so it can be determined whether the existing system has the excess capacity to handle the additional proposed impervious surface. 3)OK DATE emailed 5/22/08 PAGE 1 OF 1 . 5/22/08 - 4)Provide a driveway profile of the centerline of the proposed driveway. Maximum slope of driveway can not exceed 14%. Please explain how the cross slopes of the new and existing driveway are to meet. Cross slopes can not exceed 4% on the new driveway. 5/22/08 – 5)It is not possible forthe existing driweay to be sloped as the contours are showing. Please revise contours on site plan as required. 5/22/08 – 6) The impervious surface of the addition appears larger than what was indicated. Please revise the impervious surface calculations to include the roof overhang of the addition. Please resubmit three copies of the revised plans/documents to a Development Services Coordinator. You may contact me at 425-771-0220 if you have specific questions regarding these plan corrections. DATE emailed 5/22/08 PAGE 1 OF 1 .